Total laboratory automation: Do stat tests still matter?
Dolci, Alberto; Giavarina, Davide; Pasqualetti, Sara; Szőke, Dominika; Panteghini, Mauro
2017-07-01
During the past decades the healthcare systems have rapidly changed and today hospital care is primarily advocated for critical patients and acute treatments, for which laboratory test results are crucial and need to be always reported in predictably short turnaround time (TAT). Laboratories in the hospital setting can face this challenge by changing their organization from a compartmentalized laboratory department toward a decision making-based laboratory department. This requires the implementation of a core laboratory, that exploits total laboratory automation (TLA) using technological innovation in analytical platforms, track systems and information technology, including middleware, and a number of satellite specialized laboratory sections cooperating with care teams for specific medical conditions. In this laboratory department model, the short TAT for all first-line tests performed by TLA in the core laboratory represents the key paradigm, where no more stat testing is required because all samples are handled in real-time and (auto)validated results dispatched in a time that fulfills clinical needs. To optimally reach this goal, laboratories should be actively involved in managing all the steps covering the total examination process, speeding up also extra-laboratory phases, such sample delivery. Furthermore, to warrant effectiveness and not only efficiency, all the processes, e.g. specimen integrity check, should be managed by middleware through a predefined set of rules defined in light of the clinical governance. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Employee Engagement Is Vital for the Successful Selection of a Total Laboratory Automation System.
Yu, Hoi-Ying E; Wilkerson, Myra L
2017-11-08
To concretely outline a process for selecting a total laboratory automation system that connects clinical chemistry, hematology, and coagulation analyzers and to serve as a reference for other laboratories. In Phase I, a committee including the laboratory's directors and technologists conducted a review of 5 systems based on formal request for information process, site visits, and vendor presentations. We developed evaluation criteria and selected the 2 highest performing systems. In Phase II, we executed a detailed comparison of the 2 vendors based on cost, instrument layout, workflow design, and future potential. In addition to selecting a laboratory automation system, we used the process to ensure employee engagement in preparation for implementation. Selecting a total laboratory automation system is a complicated process. This paper provides practical guide in how a thorough selection process can be done with participation of key stakeholders. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Mutters, Nico T.; Hodiamont, Caspar J.; de Jong, Menno D.; Overmeijer, Hendri P. J.; van den Boogaard, Mandy; Visser, Caroline E.
2014-01-01
Microbiological laboratories seek technologically innovative solutions to cope with large numbers of samples and limited personnel and financial resources. One platform that has recently become available is the Kiestra Total Laboratory Automation (TLA) system (BD Kiestra B.V., the Netherlands). This
Laboratory Automation and Middleware.
Riben, Michael
2015-06-01
The practice of surgical pathology is under constant pressure to deliver the highest quality of service, reduce errors, increase throughput, and decrease turnaround time while at the same time dealing with an aging workforce, increasing financial constraints, and economic uncertainty. Although not able to implement total laboratory automation, great progress continues to be made in workstation automation in all areas of the pathology laboratory. This report highlights the benefits and challenges of pathology automation, reviews middleware and its use to facilitate automation, and reviews the progress so far in the anatomic pathology laboratory. Copyright © 2015 Elsevier Inc. All rights reserved.
Laboratory automation: trajectory, technology, and tactics.
Markin, R S; Whalen, S A
2000-05-01
Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a
Sarkozi, Laszlo; Simson, Elkin; Ramanathan, Lakshmi
2003-03-01
Thirty-six years of data and history of laboratory practice at our institution has enabled us to follow the effects of analytical automation, then recently pre-analytical and post-analytical automation on productivity, cost reduction and enhanced quality of service. In 1998, we began the operation of a pre- and post-analytical automation system (robotics), together with an advanced laboratory information system to process specimens prior to analysis, deliver them to various automated analytical instruments, specimen outlet racks and finally to refrigerated stockyards. By the end of 3 years of continuous operation, we compared the chemistry part of the system with the prior 33 years and quantitated the financial impact of the various stages of automation. Between 1965 and 2000, the Consumer Price Index increased by a factor of 5.5 in the United States. During the same 36 years, at our institution's Chemistry Department the productivity (indicated as the number of reported test results/employee/year) increased from 10,600 to 104,558 (9.3-fold). When expressed in constant 1965 dollars, the total cost per test decreased from 0.79 dollars to 0.15 dollars. Turnaround time for availability of results on patient units decreased to the extent that Stat specimens requiring a turnaround time of productivity together with decreased operational cost. It enabled us to significantly increase our workload together with a reduction of personnel. In addition, stats are handled easily and there are benefits such as safer working conditions and improved sample identification, which are difficult to quantify at this stage.
Nonanalytic Laboratory Automation: A Quarter Century of Progress.
Hawker, Charles D
2017-06-01
Clinical laboratory automation has blossomed since the 1989 AACC meeting, at which Dr. Masahide Sasaki first showed a western audience what his laboratory had implemented. Many diagnostics and other vendors are now offering a variety of automated options for laboratories of all sizes. Replacing manual processing and handling procedures with automation was embraced by the laboratory community because of the obvious benefits of labor savings and improvement in turnaround time and quality. Automation was also embraced by the diagnostics vendors who saw automation as a means of incorporating the analyzers purchased by their customers into larger systems in which the benefits of automation were integrated to the analyzers.This report reviews the options that are available to laboratory customers. These options include so called task-targeted automation-modules that range from single function devices that automate single tasks (e.g., decapping or aliquoting) to multifunction workstations that incorporate several of the functions of a laboratory sample processing department. The options also include total laboratory automation systems that use conveyors to link sample processing functions to analyzers and often include postanalytical features such as refrigerated storage and sample retrieval.Most importantly, this report reviews a recommended process for evaluating the need for new automation and for identifying the specific requirements of a laboratory and developing solutions that can meet those requirements. The report also discusses some of the practical considerations facing a laboratory in a new implementation and reviews the concept of machine vision to replace human inspections. © 2017 American Association for Clinical Chemistry.
Point-of-Care Test Equipment for Flexible Laboratory Automation.
You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol
2014-08-01
Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.
Managing laboratory automation.
Saboe, T J
1995-01-01
This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Finally, some comments on future automation need are discussed.
Laboratory automation and LIMS in forensics
DEFF Research Database (Denmark)
Stangegaard, Michael; Hansen, Anders Johannes; Morling, Niels
2013-01-01
. Furthermore, implementation of automated liquid handlers reduces the risk of sample misplacement. A LIMS can efficiently control the sample flow through the laboratory and manage the results of the conducted tests for each sample. Integration of automated liquid handlers with a LIMS provides the laboratory......Implementation of laboratory automation and LIMS in a forensic laboratory enables the laboratory, to standardize sample processing. Automated liquid handlers can increase throughput and eliminate manual repetitive pipetting operations, known to result in occupational injuries to the technical staff...... with the tools required for setting up automated production lines of complex laboratory processes and monitoring the whole process and the results. Combined, this enables processing of a large number of samples. Selection of the best automated solution for an individual laboratory should be based on user...
Selecting automation for the clinical chemistry laboratory.
Melanson, Stacy E F; Lindeman, Neal I; Jarolim, Petr
2007-07-01
Laboratory automation proposes to improve the quality and efficiency of laboratory operations, and may provide a solution to the quality demands and staff shortages faced by today's clinical laboratories. Several vendors offer automation systems in the United States, with both subtle and obvious differences. Arriving at a decision to automate, and the ensuing evaluation of available products, can be time-consuming and challenging. Although considerable discussion concerning the decision to automate has been published, relatively little attention has been paid to the process of evaluating and selecting automation systems. To outline a process for evaluating and selecting automation systems as a reference for laboratories contemplating laboratory automation. Our Clinical Chemistry Laboratory staff recently evaluated all major laboratory automation systems in the United States, with their respective chemistry and immunochemistry analyzers. Our experience is described and organized according to the selection process, the important considerations in clinical chemistry automation, decisions and implementation, and we give conclusions pertaining to this experience. Including the formation of a committee, workflow analysis, submitting a request for proposal, site visits, and making a final decision, the process of selecting chemistry automation took approximately 14 months. We outline important considerations in automation design, preanalytical processing, analyzer selection, postanalytical storage, and data management. Selecting clinical chemistry laboratory automation is a complex, time-consuming process. Laboratories considering laboratory automation may benefit from the concise overview and narrative and tabular suggestions provided.
Managing laboratory automation
Saboe, Thomas J.
1995-01-01
This paper discusses the process of managing automated systems through their life cycles within the quality-control (QC) laboratory environment. The focus is on the process of directing and managing the evolving automation of a laboratory; system examples are given. The author shows how both task and data systems have evolved, and how they interrelate. A BIG picture, or continuum view, is presented and some of the reasons for success or failure of the various examples cited are explored. Fina...
Instrument calls and real-time code for laboratory automation
International Nuclear Information System (INIS)
Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.
1978-01-01
These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described
Wang, Jin; Patel, Vimal; Burns, Daniel; Laycock, John; Pandya, Kinnari; Tsoi, Jennifer; DeSilva, Binodh; Ma, Mark; Lee, Jean
2013-07-01
Regulated bioanalytical laboratories that run ligand-binding assays in support of biotherapeutics development face ever-increasing demand to support more projects with increased efficiency. Laboratory automation is a tool that has the potential to improve both quality and efficiency in a bioanalytical laboratory. The success of laboratory automation requires thoughtful evaluation of program needs and fit-for-purpose strategies, followed by pragmatic implementation plans and continuous user support. In this article, we present the development of fit-for-purpose automation of total walk-away and flexible modular modes. We shared the sustaining experience of vendor collaboration and team work to educate, promote and track the use of automation. The implementation of laboratory automation improves assay performance, data quality, process efficiency and method transfer to CRO in a regulated bioanalytical laboratory environment.
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.
Laboratory automation in clinical bacteriology: what system to choose?
Croxatto, A; Prod'hom, G; Faverjon, F; Rochais, Y; Greub, G
2016-03-01
Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Miler, Marijana; Nikolac Gabaj, Nora; Dukic, Lora; Simundic, Ana-Maria
2017-12-27
The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved. Waiting time for registration of samples in the LIS was significantly reduced from 16 (9-28) to 9 (6-16) minutes after TLA (P performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.
Automation in the clinical microbiology laboratory.
Novak, Susan M; Marlowe, Elizabeth M
2013-09-01
Imagine a clinical microbiology laboratory where a patient's specimens are placed on a conveyor belt and sent on an automation line for processing and plating. Technologists need only log onto a computer to visualize the images of a culture and send to a mass spectrometer for identification. Once a pathogen is identified, the system knows to send the colony for susceptibility testing. This is the future of the clinical microbiology laboratory. This article outlines the operational and staffing challenges facing clinical microbiology laboratories and the evolution of automation that is shaping the way laboratory medicine will be practiced in the future. Copyright © 2013 Elsevier Inc. All rights reserved.
International Nuclear Information System (INIS)
Austin, H.C.; Gray, L.M.
1982-01-01
OASIS has been providing for Oak Ridge National Laboratory's total safeguards needs since being place on line in April 1980. The system supports near real-time nuclear materials safeguards and accountability control. The original design of OASIS called for an automated facsimile of a 741 document to be prepared as a functional by-product of updating the inventory. An attempt was made to utilize, intact, DOE-Albuquerque's automated 741 system to generate the facsimile; however, the five page document produced proved too cumbersome. Albuquerque's programs were modified to print an original 741 document utilizing standard DOE/NRC 741 forms. It is felt that the best features of both the automated and manually generated 741 documents have been incorporated. Automation of the source data for 741 shipping documents produces greater efficiency while reducing possible errors. Through utilization of the standard DOE/NRC form, continuity within the NMMSS system is maintained, thus minimizing the confusion and redundancy associated with facsimiles. OASIS now fulfills the original concept of near real-time accountability by furnishing a viable 741 document as a function of updating the inventory
Computer system architecture for laboratory automation
International Nuclear Information System (INIS)
Penney, B.K.
1978-01-01
This paper describes the various approaches that may be taken to provide computing resources for laboratory automation. Three distinct approaches are identified, the single dedicated small computer, shared use of a larger computer, and a distributed approach in which resources are provided by a number of computers, linked together, and working in some cooperative way. The significance of the microprocessor in laboratory automation is discussed, and it is shown that it is not simply a cheap replacement of the minicomputer. (Auth.)
Energy Technology Data Exchange (ETDEWEB)
Morris, W.F.; Ames, H.S.
1977-07-01
In January 1976, the Water Resources Division of the U.S. Geological Survey asked Lawrence Livermore Laboratory to conduct a feasibility study for automation of the National Water Quality (NWQ) Laboratory in Denver, Colorado (formerly Denver Central Laboratory). Results of the study were published in the Feasibility Study for Automation of the Central Laboratories, Lawrence Livermore Laboratory, Rept. UCRL-52001 (1976). Because the present system for processing water samples was found inadequate to meet the demands of a steadily increasing workload, new automation was recommended. In this document we present details necessary for future implementation of the new system, as well as descriptions of current laboratory automatic data processing and analytical facilities to better define the scope of the project and illustrate what the new system will accomplish. All pertinent inputs, outputs, and other operations that define the project are shown in functional designs.
International Nuclear Information System (INIS)
Morris, W.F.; Ames, H.S.
1977-01-01
In January 1976, the Water Resources Division of the U.S. Geological Survey asked Lawrence Livermore Laboratory to conduct a feasibility study for automation of the National Water Quality (NWQ) Laboratory in Denver, Colorado (formerly Denver Central Laboratory). Results of the study were published in the Feasibility Study for Automation of the Central Laboratories, Lawrence Livermore Laboratory, Rept. UCRL-52001 (1976). Because the present system for processing water samples was found inadequate to meet the demands of a steadily increasing workload, new automation was recommended. In this document we present details necessary for future implementation of the new system, as well as descriptions of current laboratory automatic data processing and analytical facilities to better define the scope of the project and illustrate what the new system will accomplish. All pertinent inputs, outputs, and other operations that define the project are shown in functional designs
The standard laboratory module approach to automation of the chemical laboratory
International Nuclear Information System (INIS)
Hollen, R.M.; Erkkila, T.H.
1993-01-01
Automation of the technology and practice of environmental laboratory automation has not been as rapid or complete as one might expect. Confined to autosamplers and limited robotic systems, our ability to apply production concepts to environmental analytical analysis is not great. With the impending remediation of our hazardous waste sites in the US, only the application of production chemistry techniques will even begin to provide those responsible with the necessary knowledge to accomplish the cleanup expeditiously and safely. Tightening regulatory requirements have already mandated staggering increases in sampling and characterization needs with the future only guaranteeing greater demands. The Contaminant Analysis Automation Program has been initiated by our government to address these current and future characterization by application of a new robotic paradigm for analytical chemistry. By using standardized modular instruments, named Standard Laboratory Modules, flexible automation systems can rapidly be configured to apply production techniques to our nations environmental problems at-site
Armbruster, David A; Overcash, David R; Reyes, Jaime
2014-01-01
The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory
Recent trends in laboratory automation in the pharmaceutical industry.
Rutherford, M L; Stinger, T
2001-05-01
The impact of robotics and automation on the pharmaceutical industry over the last two decades has been significant. In the last ten years, the emphasis of laboratory automation has shifted from the support of manufactured products and quality control of laboratory applications, to research and development. This shift has been the direct result of an increased emphasis on the identification, development and eventual marketing of innovative new products. In this article, we will briefly identify and discuss some of the current trends in laboratory automation in the pharmaceutical industry as they apply to research and development, including screening, sample management, combinatorial chemistry, ADME/Tox and pharmacokinetics.
Bloodborne Viral Pathogen Contamination in the Era of Laboratory Automation.
Bryan, Andrew; Cook, Linda; Atienza, Ederlyn E; Kuypers, Jane; Cent, Anne; Baird, Geoffrey S; Coombs, Robert W; Jerome, Keith R; Wener, Mark H; Butler-Wu, Susan M
2016-07-01
The CDC states that laboratory testing for persons under investigation for Ebola virus disease can be safely performed using automated laboratory instruments by adhering to bloodborne pathogen practices. We therefore sought to investigate the levels of viral contamination of a total laboratory automation (TLA) system to guide risk mitigation strategies for handling infectious agents. Environmental swabs followed by PCR for hepatitis B (HBV) and hepatitis C (HCV) viruses were taken from a chemistry TLA system during routine clinical use and after running a small number of high-titer HCV samples. Control experiments were performed to ensure the recovery of DNA and RNA viruses by swabs from a representative nonporous surface. Of 79 baseline swabs for nucleic acids performed on the TLA system, 10 were positive for HBV and 8 for HCV. Viral nucleic acid was consistently detected from swabs taken from the distal inside surface of the decapper discharge chute, with areas adjacent to the decapper instrument and the centrifuge rotor also positive for HBV or HCV nucleic acid. Contamination was occasionally detected on exposed surfaces in areas without protective barriers between samples and personnel. After running known HCV-positive samples, at least one additional site of contamination was detected on an exposed area of the line. A low level of viral contamination of automated clinical laboratory equipment occurs in clinical use. Given the risks associated with highly infectious agents, there is a need for risk-mitigation procedures when handling all samples. © 2016 American Association for Clinical Chemistry.
Laboratory automation in a functional programming language.
Runciman, Colin; Clare, Amanda; Harkness, Rob
2014-12-01
After some years of use in academic and research settings, functional languages are starting to enter the mainstream as an alternative to more conventional programming languages. This article explores one way to use Haskell, a functional programming language, in the development of control programs for laboratory automation systems. We give code for an example system, discuss some programming concepts that we need for this example, and demonstrate how the use of functional programming allows us to express and verify properties of the resulting code. © 2014 Society for Laboratory Automation and Screening.
PLACE: an open-source python package for laboratory automation, control, and experimentation.
Johnson, Jami L; Tom Wörden, Henrik; van Wijk, Kasper
2015-02-01
In modern laboratories, software can drive the full experimental process from data acquisition to storage, processing, and analysis. The automation of laboratory data acquisition is an important consideration for every laboratory. When implementing a laboratory automation scheme, important parameters include its reliability, time to implement, adaptability, and compatibility with software used at other stages of experimentation. In this article, we present an open-source, flexible, and extensible Python package for Laboratory Automation, Control, and Experimentation (PLACE). The package uses modular organization and clear design principles; therefore, it can be easily customized or expanded to meet the needs of diverse laboratories. We discuss the organization of PLACE, data-handling considerations, and then present an example using PLACE for laser-ultrasound experiments. Finally, we demonstrate the seamless transition to post-processing and analysis with Python through the development of an analysis module for data produced by PLACE automation. © 2014 Society for Laboratory Automation and Screening.
Automation in Clinical Microbiology
Ledeboer, Nathan A.
2013-01-01
Historically, the trend toward automation in clinical pathology laboratories has largely bypassed the clinical microbiology laboratory. In this article, we review the historical impediments to automation in the microbiology laboratory and offer insight into the reasons why we believe that we are on the cusp of a dramatic change that will sweep a wave of automation into clinical microbiology laboratories. We review the currently available specimen-processing instruments as well as the total laboratory automation solutions. Lastly, we outline the types of studies that will need to be performed to fully assess the benefits of automation in microbiology laboratories. PMID:23515547
Neubert, Sebastian; Göde, Bernd; Gu, Xiangyu; Stoll, Norbert; Thurow, Kerstin
2017-04-01
Modern business process management (BPM) is increasingly interesting for laboratory automation. End-to-end workflow automation and improved top-level systems integration for information technology (IT) and automation systems are especially prominent objectives. With the ISO Standard Business Process Model and Notation (BPMN) 2.X, a system-independent and interdisciplinary accepted graphical process control notation is provided, allowing process analysis, while also being executable. The transfer of BPM solutions to structured laboratory automation places novel demands, for example, concerning the real-time-critical process and systems integration. The article discusses the potential of laboratory execution systems (LESs) for an easier implementation of the business process management system (BPMS) in hierarchical laboratory automation. In particular, complex application scenarios, including long process chains based on, for example, several distributed automation islands and mobile laboratory robots for a material transport, are difficult to handle in BPMSs. The presented approach deals with the displacement of workflow control tasks into life science specialized LESs, the reduction of numerous different interfaces between BPMSs and subsystems, and the simplification of complex process modelings. Thus, the integration effort for complex laboratory workflows can be significantly reduced for strictly structured automation solutions. An example application, consisting of a mixture of manual and automated subprocesses, is demonstrated by the presented BPMS-LES approach.
Streamlining and automation of radioanalytical methods at a commercial laboratory
Energy Technology Data Exchange (ETDEWEB)
Harvey, J.T.; Dillard, J.W. [IT Corp., Knoxville, TN (United States)
1993-12-31
Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed.
Streamlining and automation of radioanalytical methods at a commercial laboratory
International Nuclear Information System (INIS)
Harvey, J.T.; Dillard, J.W.
1993-01-01
Through the careful planning and design of laboratory facilities and incorporation of modern instrumentation and robotics systems, properly trained and competent laboratory associates can efficiently and safely handle radioactive and mixed waste samples. This paper addresses the potential improvements radiochemistry and mixed waste laboratories can achieve utilizing robotics for automated sample analysis. Several examples of automated systems for sample preparation and analysis will be discussed
Evangelopoulos, Angelos A; Dalamaga, Maria; Panoutsopoulos, Konstantinos; Dima, Kleanthi
2013-01-01
In the early 80s, the word automation was used in the clinical laboratory setting referring only to analyzers. But in late 80s and afterwards, automation found its way into all aspects of the diagnostic process, embracing not only the analytical but also the pre- and post-analytical phase. While laboratories in the eastern world, mainly Japan, paved the way for laboratory automation, US and European laboratories soon realized the benefits and were quick to follow. Clearly, automation and robotics will be a key survival tool in a very competitive and cost-concious healthcare market. What sets automation technology apart from so many other efficiency solutions are the dramatic savings that it brings to the clinical laboratory. Further standardization will assure the success of this revolutionary new technology. One of the main difficulties laboratory managers and personnel must deal with when studying solutions to reengineer a laboratory is familiarizing themselves with the multidisciplinary and technical terminology of this new and exciting field. The present review/glossary aims at giving an overview of the most frequently used terms within the scope of laboratory automation and to put laboratory automation on a sounder linguistic basis.
Automation and Robotics in the Laboratory.
DiCesare, Frank; And Others
1985-01-01
A general laboratory course featuring microcomputer interfacing for data acquisition, process control and automation, and robotics was developed at Rensselaer Polytechnic Institute and is now available to all junior engineering students. The development and features of the course are described. (JN)
Casis, E; Garrido, A; Uranga, B; Vives, A; Zufiaurre, C
2001-01-01
Total laboratory automation (TLA) can be substituted in mid-size laboratories by a computer sample workflow control (virtual automation). Such a solution has been implemented in our laboratory using PSM, software developed in cooperation with Roche Diagnostics (Barcelona, Spain), to this purpose. This software is connected to the online analyzers and to the laboratory information system and is able to control and direct the samples working as an intermediate station. The only difference with TLA is the replacement of transport belts by personnel of the laboratory. The implementation of this virtual automation system has allowed us the achievement of the main advantages of TLA: workload increase (64%) with reduction in the cost per test (43%), significant reduction in the number of biochemistry primary tubes (from 8 to 2), less aliquoting (from 600 to 100 samples/day), automation of functional testing, drastic reduction of preanalytical errors (from 11.7 to 0.4% of the tubes) and better total response time for both inpatients (from up to 48 hours to up to 4 hours) and outpatients (from up to 10 days to up to 48 hours). As an additional advantage, virtual automation could be implemented without hardware investment and significant headcount reduction (15% in our lab).
Klein, Sabrina; Nurjadi, Dennis; Horner, Susanne; Heeg, Klaus; Zimmermann, Stefan; Burckhardt, Irene
2018-04-13
While total laboratory automation (TLA) is well established in laboratory medicine, only a few microbiological laboratories are using TLA systems. Especially in terms of speed and accuracy, working with TLA is expected to be superior to conventional microbiology. We compared in total 35,564 microbiological urine cultures with and without incubation and processing with BD Kiestra TLA for a 6-month period each retrospectively. Sixteen thousand three hundred thirty-eight urine samples were analyzed in the pre-TLA period and 19,226 with TLA. Sixty-two percent (n = 10,101/16338) of the cultures processed without TLA and 68% (n = 13,102/19226) of the cultures processed with TLA showed growth. There were significantly more samples with two or more species per sample and with low numbers of colony forming units (CFU) after incubation with TLA. Regarding the type of bacteria, there were comparable amounts of Enterobacteriaceae in the samples, slightly less non-fermenting Gram-negative bacteria, but significantly more Gram-positive cocci, and Gram-positive rods. Especially Alloscardivia omnicolens, Gardnerella vaginalis, Actinomyces spp., and Actinotignum schaalii were significantly more abundant in the samples incubated and processed with TLA. The time to report was significantly lower in the TLA processed samples by 1.5 h. We provide the first report in Europe of a large number of urine samples processed with TLA. TLA showed enhanced growth of non-classical and rarely cultured bacteria from urine samples. Our findings suggest that previously underestimated bacteria may be relevant pathogens for urinary tract infections. Further studies are needed to confirm our findings.
Automation in control laboratory and related information management system
International Nuclear Information System (INIS)
Gopalan, B.; Syamsundar, S.
1997-01-01
In the field of technology, the word automation is often employed to indicate many types of mechanized operations, though in the strict sense it means those operations which involve application of an element of knowledge or decision making without the intervention of human mind. In laboratory practice for example, the use of multi-sample array turret and millivolt recorder connected to a spectrophotometer represents a situation of mechanized operation as these gadgets help eliminating human muscle power. If a micro processor or a computer is connected to the above equipment for interpreting the measured parameters and establishing calibration graphs or display concentration results, then a real automated situation results where the application of human mind is eliminated. The state of the art of modern laboratory analysis abounds in the employment of automatic analytical equipment thanks to the development in the field of VLSI, computer, software etc. and this has given rise to the concept of laboratory automation
Pyrochemical processing automation at Lawrence Livermore National Laboratory
International Nuclear Information System (INIS)
Dennison, D.K.; Domning, E.E.; Seivers, R.
1991-01-01
Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system for pyrochemical processing of special nuclear materials (SNM). The system utilizes a glove box, an automated tilt-pour furnace (TPF), an IBM developed gantry robot, and specialized automation tooling. All material handling within the glove box (i.e., furnace loading, furnace unloading, product and slag separation, and product packaging) is performed automatically. The objectives of the effort are to increase process productivity, decrease operator radiation, reduce process wastes, and demonstrate system reliability and availability. This paper provides an overview of the automated system hardware, outlines the overall operations sequence, and discusses the current status
Cost challenges for laboratory medicine automation in Africa ...
African Journals Online (AJOL)
Automation in laboratory medicine is inevitable and the only way forward especially in Africa where the staff turnover is high due to migration of experienced staff to Europe and America. Described here are the common issues that laboratory Managers and Directors encounter when upgrading, replacing analytical systems ...
Improving patient safety via automated laboratory-based adverse event grading.
Niland, Joyce C; Stiller, Tracey; Neat, Jennifer; Londrc, Adina; Johnson, Dina; Pannoni, Susan
2012-01-01
The identification and grading of adverse events (AEs) during the conduct of clinical trials is a labor-intensive and error-prone process. This paper describes and evaluates a software tool developed by City of Hope to automate complex algorithms to assess laboratory results and identify and grade AEs. We compared AEs identified by the automated system with those previously assessed manually, to evaluate missed/misgraded AEs. We also conducted a prospective paired time assessment of automated versus manual AE assessment. We found a substantial improvement in accuracy/completeness with the automated grading tool, which identified an additional 17% of severe grade 3-4 AEs that had been missed/misgraded manually. The automated system also provided an average time saving of 5.5 min per treatment course. With 400 ongoing treatment trials at City of Hope and an average of 1800 laboratory results requiring assessment per study, the implications of these findings for patient safety are enormous.
Hawker, Charles D; Garr, Susan B; Hamilton, Leslie T; Penrose, John R; Ashwood, Edward R; Weiss, Ronald L
2002-10-01
Our laboratory, a large, commercial, esoteric reference laboratory, sought some form of total laboratory automation to keep pace with rapid growth of specimen volumes as well as to meet competitive demands for cost reduction and improved turnaround time. We conducted a systematic evaluation of our needs, which led to the development of a plan to implement an automated transport and sorting system. We systematically analyzed and studied our specimen containers, test submission requirements and temperatures, and the workflow and movement of people, specimens, and information throughout the laboratory. We performed an intricate timing study that identified bottlenecks in our manual handling processes. We also evaluated various automation options. The automation alternative viewed to best meet our needs was a transport and sorting system from MDS AutoLab. Our comprehensive plan also included a new standardized transport tube; a centralized automated core laboratory for higher volume tests; a new "automation-friendly" software system for order entry, tracking, and process control; a complete reengineering of our order-entry, handling, and tracking processes; and remodeling of our laboratory facility and specimen processing area. The scope of this project and its potential impact on overall laboratory operations and performance justified the extensive time we invested (nearly 4 years) in a systematic approach to the evaluation, design, and planning of this project.
PR-PR: cross-platform laboratory automation system.
Linshiz, Gregory; Stawski, Nina; Goyal, Garima; Bi, Changhao; Poust, Sean; Sharma, Monica; Mutalik, Vivek; Keasling, Jay D; Hillson, Nathan J
2014-08-15
To enable protocol standardization, sharing, and efficient implementation across laboratory automation platforms, we have further developed the PR-PR open-source high-level biology-friendly robot programming language as a cross-platform laboratory automation system. Beyond liquid-handling robotics, PR-PR now supports microfluidic and microscopy platforms, as well as protocol translation into human languages, such as English. While the same set of basic PR-PR commands and features are available for each supported platform, the underlying optimization and translation modules vary from platform to platform. Here, we describe these further developments to PR-PR, and demonstrate the experimental implementation and validation of PR-PR protocols for combinatorial modified Golden Gate DNA assembly across liquid-handling robotic, microfluidic, and manual platforms. To further test PR-PR cross-platform performance, we then implement and assess PR-PR protocols for Kunkel DNA mutagenesis and hierarchical Gibson DNA assembly for microfluidic and manual platforms.
Laboratory automation: a challenge for the 1990s.
Mordini, C
1994-01-01
THERE IS TREMENDOUS PRESSURE ON INDUSTRY AND LABORATORIES TO DEVELOP INCREASINGLY COMPLEX PROCUCTS: for example catalysts, chiral chemicals, drugs and ceramics; conform to regulations; cope with increasingly severe competition; and meet steadily increasing costs. It is difficult, in this situation, to remain productive and competitive. It is vital to be equipped with, and be able to use appropriately, all the suitable methodologies and technologies. Working methods and personnel have to be appropriate. The future depends on three interdependent domains: automation in the broadest sense of the word, instrumentation and information systems. The easy work has already been done. Between 1984 and 1990, it was a question of going from nothing to something; now, it is necessary to increase and optimize.THEREFORE, THE CRUCIAL QUESTION IS NOW: 'how can we go quicker in experimentation and acquire more knowledge, while spending less money?' One solution is to use all the aspects of automation (robotics, instrumentation, data). Successful laboratory automation depends.on: shortened time to market; improved efficiency/cost ratio; motivation/competence/ expertise; communication; and knowledge acquisition. This paper examines some of the major technological areas of application.
Cost challenges for laboratory medicine automation in Africa
African Journals Online (AJOL)
cqq1a
2010-09-29
Sep 29, 2010 ... Described here are the common issues that laboratory Managers and ... in the both the hardware and software utilised by analyzers every two to ... maintain the high quality of results requires automation in order not to ...
The contaminant analysis automation robot implementation for the automated laboratory
International Nuclear Information System (INIS)
Younkin, J.R.; Igou, R.E.; Urenda, T.D.
1995-01-01
The Contaminant Analysis Automation (CAA) project defines the automated laboratory as a series of standard laboratory modules (SLM) serviced by a robotic standard support module (SSM). These SLMs are designed to allow plug-and-play integration into automated systems that perform standard analysis methods (SAM). While the SLMs are autonomous in the execution of their particular chemical processing task, the SAM concept relies on a high-level task sequence controller (TSC) to coordinate the robotic delivery of materials requisite for SLM operations, initiate an SLM operation with the chemical method dependent operating parameters, and coordinate the robotic removal of materials from the SLM when its commands and events has been established to allow ready them for transport operations as well as performing the Supervisor and Subsystems (GENISAS) software governs events from the SLMs and robot. The Intelligent System Operating Environment (ISOE) enables the inter-process communications used by GENISAS. CAA selected the Hewlett-Packard Optimized Robot for Chemical Analysis (ORCA) and its associated Windows based Methods Development Software (MDS) as the robot SSM. The MDS software is used to teach the robot each SLM position and required material port motions. To allow the TSC to command these SLM motions, a hardware and software implementation was required that allowed message passing between different operating systems. This implementation involved the use of a Virtual Memory Extended (VME) rack with a Force CPU-30 computer running VxWorks; a real-time multitasking operating system, and a Radiuses PC compatible VME computer running MDS. A GENISAS server on The Force computer accepts a transport command from the TSC, a GENISAS supervisor, over Ethernet and notifies software on the RadiSys PC of the pending command through VMEbus shared memory. The command is then delivered to the MDS robot control software using a Windows Dynamic Data Exchange conversation
Total error components - isolation of laboratory variation from method performance
International Nuclear Information System (INIS)
Bottrell, D.; Bleyler, R.; Fisk, J.; Hiatt, M.
1992-01-01
The consideration of total error across sampling and analytical components of environmental measurements is relatively recent. The U.S. Environmental Protection Agency (EPA), through the Contract Laboratory Program (CLP), provides complete analyses and documented reports on approximately 70,000 samples per year. The quality assurance (QA) functions of the CLP procedures provide an ideal data base-CLP Automated Results Data Base (CARD)-to evaluate program performance relative to quality control (QC) criteria and to evaluate the analysis of blind samples. Repetitive analyses of blind samples within each participating laboratory provide a mechanism to separate laboratory and method performance. Isolation of error sources is necessary to identify effective options to establish performance expectations, and to improve procedures. In addition, optimized method performance is necessary to identify significant effects that result from the selection among alternative procedures in the data collection process (e.g., sampling device, storage container, mode of sample transit, etc.). This information is necessary to evaluate data quality; to understand overall quality; and to provide appropriate, cost-effective information required to support a specific decision
International Nuclear Information System (INIS)
Boyle, W.G.; Barton, G.W.
1979-01-01
We studied the feasibility of computerized automation of the Analytical Laboratories Section at NASA's Lewis Research Center. Since that laboratory's duties are not routine, we set our automation goals with that in mind. We selected four instruments as the most likely automation candidates: an atomic absorption spectrophotometer, an emission spectrometer, an x-ray fluorescence spectrometer, and an x-ray diffraction unit. Our study describes two options for computer automation: a time-shared central computer and a system with microcomputers for each instrument connected to a central computer. A third option, presented for future planning, expands the microcomputer version. We determine costs and benefits for each option. We conclude that the microcomputer version best fits the goals and duties of the laboratory and that such an automated system is needed to meet the laboratory's future requirements
White, L; Terner, C
2001-01-01
The initial efforts of e-health have fallen far short of expectations. They were buoyed by the hype and excitement of the Internet craze but limited by their lack of understanding of important market and environmental factors. E-health now recognizes that legacy systems and processes are important, that there is a technology adoption process that needs to be followed, and that demonstrable value drives adoption. Initial e-health transaction solutions have targeted mostly low-cost problems. These solutions invariably are difficult to integrate into existing systems, typically requiring manual interfacing to supported processes. This limitation in particular makes them unworkable for large volume providers. To meet the needs of these providers, e-health companies must rethink their approaches, appropriately applying technology to seamlessly integrate all steps into existing business functions. E-automation is a transaction technology that automates steps, integration of steps, and information communication demands, resulting in comprehensive automation of entire business functions. We applied e-automation to create a billing management solution for clinical reference laboratories. Large volume, onerous regulations, small margins, and only indirect access to patients challenge large laboratories' billing departments. Couple these problems with outmoded, largely manual systems and it becomes apparent why most laboratory billing departments are in crisis. Our approach has been to focus on the most significant and costly problems in billing: errors, compliance, and system maintenance and management. The core of the design relies on conditional processing, a "universal" communications interface, and ASP technologies. The result is comprehensive automation of all routine processes, driving out errors and costs. Additionally, compliance management and billing system support and management costs are dramatically reduced. The implications of e-automated processes can extend
Sample tracking in an automated cytogenetic biodosimetry laboratory for radiation mass casualties
International Nuclear Information System (INIS)
Martin, P.R.; Berdychevski, R.E.; Subramanian, U.; Blakely, W.F.; Prasanna, P.G.S.
2007-01-01
Chromosome-aberration-based dicentric assay is expected to be used after mass-casualty life-threatening radiation exposures to assess radiation dose to individuals. This will require processing of a large number of samples for individual dose assessment and clinical triage to aid treatment decisions. We have established an automated, high-throughput, cytogenetic biodosimetry laboratory to process a large number of samples for conducting the dicentric assay using peripheral blood from exposed individuals according to internationally accepted laboratory protocols (i.e., within days following radiation exposures). The components of an automated cytogenetic biodosimetry laboratory include blood collection kits for sample shipment, a cell viability analyzer, a robotic liquid handler, an automated metaphase harvester, a metaphase spreader, high-throughput slide stainer and coverslipper, a high-throughput metaphase finder, multiple satellite chromosome-aberration analysis systems, and a computerized sample-tracking system. Laboratory automation using commercially available, off-the-shelf technologies, customized technology integration, and implementation of a laboratory information management system (LIMS) for cytogenetic analysis will significantly increase throughput. This paper focuses on our efforts to eliminate data-transcription errors, increase efficiency, and maintain samples' positive chain-of-custody by sample tracking during sample processing and data analysis. This sample-tracking system represents a 'beta' version, which can be modeled elsewhere in a cytogenetic biodosimetry laboratory, and includes a customized LIMS with a central server, personal computer workstations, barcode printers, fixed station and wireless hand-held devices to scan barcodes at various critical steps, and data transmission over a private intra-laboratory computer network. Our studies will improve diagnostic biodosimetry response, aid confirmation of clinical triage, and medical
Sample tracking in an automated cytogenetic biodosimetry laboratory for radiation mass casualties
Energy Technology Data Exchange (ETDEWEB)
Martin, P.R.; Berdychevski, R.E.; Subramanian, U.; Blakely, W.F. [Armed Forces Radiobiology Research Institute, Uniformed Services University of Health Sciences, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States); Prasanna, P.G.S. [Armed Forces Radiobiology Research Institute, Uniformed Services University of Health Sciences, 8901 Wisconsin Avenue, Bethesda, MD 20889-5603 (United States)], E-mail: prasanna@afrri.usuhs.mil
2007-07-15
Chromosome-aberration-based dicentric assay is expected to be used after mass-casualty life-threatening radiation exposures to assess radiation dose to individuals. This will require processing of a large number of samples for individual dose assessment and clinical triage to aid treatment decisions. We have established an automated, high-throughput, cytogenetic biodosimetry laboratory to process a large number of samples for conducting the dicentric assay using peripheral blood from exposed individuals according to internationally accepted laboratory protocols (i.e., within days following radiation exposures). The components of an automated cytogenetic biodosimetry laboratory include blood collection kits for sample shipment, a cell viability analyzer, a robotic liquid handler, an automated metaphase harvester, a metaphase spreader, high-throughput slide stainer and coverslipper, a high-throughput metaphase finder, multiple satellite chromosome-aberration analysis systems, and a computerized sample-tracking system. Laboratory automation using commercially available, off-the-shelf technologies, customized technology integration, and implementation of a laboratory information management system (LIMS) for cytogenetic analysis will significantly increase throughput. This paper focuses on our efforts to eliminate data-transcription errors, increase efficiency, and maintain samples' positive chain-of-custody by sample tracking during sample processing and data analysis. This sample-tracking system represents a 'beta' version, which can be modeled elsewhere in a cytogenetic biodosimetry laboratory, and includes a customized LIMS with a central server, personal computer workstations, barcode printers, fixed station and wireless hand-held devices to scan barcodes at various critical steps, and data transmission over a private intra-laboratory computer network. Our studies will improve diagnostic biodosimetry response, aid confirmation of clinical triage, and
A data automation system at Los Alamos National Laboratory
International Nuclear Information System (INIS)
Betts, S.E.; Schneider, C.M.; Pickrell, M.M.
2001-01-01
Idaho National Engineering and Environmental Laboratory (INEEL) has developed an automated computer program, Data Review Expert System (DRXS), for reviewing nondestructive assay (NDA) data. DRXS significantly reduces the data review time needed to meet characterization requirements for the Waste Isolation Pilot Plant (WIPP). Los Alamos National Laboratory (LANL) is in the process of developing a computer program, Software System Logic for Intelligent Certification (SSLIC), to automate other tasks associa ted with characterization of Transuranic Waste (TRU) samples. LANL has incorporated a version of DRXS specific to LANL's isotopic data into SSLIC. This version of SSLIC was audited by the National Transuranic Program on October, 24, 2001. This paper will present the results of the audit, and discuss future plans for SSLIC including the integration on the INEELLANL developed Rule Editor.
AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL
Directory of Open Access Journals (Sweden)
V. Z. Stetsyuk
2015-05-01
Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.
Automation of measurements in the dclf laboratory of the CSIR NML
CSIR Research Space (South Africa)
Marais, EL
2006-01-01
Full Text Available At the end of 2005 it was decided that a number of measurements performed in the dc Low Frequency (dclf) Laboratory of the CSIR National Metrology Laboratory (CSIR NML) could benefit from automation. The measurements identified were typically highly...
Flexible software architecture for user-interface and machine control in laboratory automation.
Arutunian, E B; Meldrum, D R; Friedman, N A; Moody, S E
1998-10-01
We describe a modular, layered software architecture for automated laboratory instruments. The design consists of a sophisticated user interface, a machine controller and multiple individual hardware subsystems, each interacting through a client-server architecture built entirely on top of open Internet standards. In our implementation, the user-interface components are built as Java applets that are downloaded from a server integrated into the machine controller. The user-interface client can thereby provide laboratory personnel with a familiar environment for experiment design through a standard World Wide Web browser. Data management and security are seamlessly integrated at the machine-controller layer using QNX, a real-time operating system. This layer also controls hardware subsystems through a second client-server interface. This architecture has proven flexible and relatively easy to implement and allows users to operate laboratory automation instruments remotely through an Internet connection. The software architecture was implemented and demonstrated on the Acapella, an automated fluid-sample-processing system that is under development at the University of Washington.
Measurement of the total antioxidant response in preeclampsia with a novel automated method.
Harma, Mehmet; Harma, Muge; Erel, Ozcan
2005-01-10
Preeclampsia is one of the most serious complications of pregnancy. Free radical damage has been implicated in the pathophysiology of this condition. In this study, we aimed to measure the antioxidant capacity in plasma samples from normotensive and preeclamptic pregnant women to evaluate their antioxidant status using a more recently developed automated measurement method. Our study group contained 42 women, 24 of whom had preeclampsia, while 18 had normotensive pregnancies. We measured the total plasma antioxidant capacity for all patients, as well as the levels of four major individual plasma antioxidant components; albumin, uric acid, ascorbic acid and bilirubin, and as a reciprocal measure, their total plasma peroxide levels. Statistically significant differences (determined using Student's t-test) were noted between the normotensive and the preeclamptic groups for their total antioxidant responses and their vitamin C levels (1.31 +/- 0.12 mmol versus 1.06 +/- 0.41 mmol Trolox eq./L; 30.2 +/- 17.83 micromol/L versus 18.1 +/- 11.37 micromol/L, respectively), which were both considerably reduced in the preeclamptic patients. In contrast, the total plasma peroxide levels were significantly elevated in this group (49.8 +/- 14.3 micromol/L versus 38.8 +/- 9.6 micromol/L). We found a decreased total antioxidant response in preeclamptic patients using a simple, rapid and reliable automated colorimetric assay, which may suitable for use in any routine clinical biochemistry laboratory, and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow up of the levels of oxidative stress in preeclampsia.
The use of robots for automation in the radiochemical laboratory
International Nuclear Information System (INIS)
Huddleston, J.
1988-01-01
The use of robotic systems for automated processes such as overnight operations, procedures involving radiation hazards in radiochemical laboratories is discussed. Particular reference is made to their use in analytical problems. Their flexibility is emphasised. (U.K.)
Feasibility study for the computerized automation of the Laboratory Services Branch of EPA Region IV
International Nuclear Information System (INIS)
Boyle, W.G. Jr.; Barton, G.W. Jr.; Taber, L.
1978-01-01
This report is a study of the feasibility of computerized automation of the Laboratory Services Branch of the Environmental Protection Agency's Region IV. The LSB provides chemical analytical support for a number of EPA divisions; its primary function at present is compliance monitoring, field surveys, and oil identification. Automation of the LSB is not only feasible but also highly desirable. Automation systems are proposed that will make major improvements in analytical capacity, quality control, sample management, and reporting capabilities. Most of these automation systems are similar to those already developed and installed at other EPA laboratories. These systems have options that include limited modifications suggested as a result of the study of the LSB Laboratory, and also include communications hardware and software for a Sample File Control host computer. It is estimated that the initial cost of three of the four options considered would be recouped in approximately three years through increased capacity and efficiency of operation
Sparkes, Andrew; Clare, Amanda
2012-05-15
Modern automated laboratories need substantial data management solutions to both store and make accessible the details of the experiments they perform. To be useful, a modern Laboratory Information Management System (LIMS) should be flexible and easily extensible to support evolving laboratory requirements, and should be based on the solid foundations of a robust, well-designed database. We have developed such a database schema to support an automated laboratory that performs experiments in systems biology and high-throughput screening. We describe the design of the database schema (AutoLabDB), detailing the main features and describing why we believe it will be relevant to LIMS manufacturers or custom builders. This database has been developed to support two large automated Robot Scientist systems over the last 5 years, where it has been used as the basis of an LIMS that helps to manage both the laboratory and all the experiment data produced.
GESCAL: Quality management automated system for a calibration and test laboratory
International Nuclear Information System (INIS)
Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.
1998-01-01
GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff
International Nuclear Information System (INIS)
O'Hara, Matthew J.; Farawila, Anne F.; Grate, Jay W.
2009-01-01
The identification and quantification of targeted α- and β-emitting radionuclides via destructive analysis in complex radioactive liquid matrices is highly challenging. Analyses are typically accomplished at on- or off-site laboratories through laborious sample preparation steps and extensive chemical separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, alpha energy spectroscopy, mass spectrometry). Analytical results may take days or weeks to report. When an industrial-scale plant requires periodic or continuous monitoring of radionuclides as an indication of the composition of its feed stream, diversion of safeguarded nuclides, or of plant operational conditions (for example), radiochemical measurements should be rapid, but not at the expense of precision and accuracy. Scientists at Pacific Northwest National Laboratory have developed and characterized a host of automated radioanalytical systems designed to perform reproducible and rapid radioanalytical processes. Platforms have been assembled for (1) automation and acceleration of sample analysis in the laboratory and (2) automated monitors for monitoring industrial scale nuclear processes on-line with near-real time results. These methods have been applied to the analysis of environmental-level actinides and fission products to high-level nuclear process fluids. Systems have been designed to integrate a number of discrete sample handling steps, including sample pretreatment (e.g., digestion and valence state adjustment) and chemical separations. The systems have either utilized on-line analyte detection or have collected the purified analyte fractions for off-line measurement applications. One PNNL system of particular note is a fully automated prototype on-line radioanalytical system designed for the Waste Treatment Plant at Hanford, WA, USA. This system demonstrated nearly continuous destructive analysis of the soft β-emitting radionuclide 99Tc in nuclear
International Nuclear Information System (INIS)
Ceylan, E.; Gencer, M.; Uzer, E.; Celik, H.
2007-01-01
To determine the oxidative and antioxidative status of plasma of patients with chronic obstructive pulmonary disease (COPD) and to compare these values with healthy smokers and healthy non-smokers control subjects using a more recently developed automated measurement method. This study involved 40 COPD patients, 25 healthy smokers, and 25 non-healthy smokers who attended the Chest Disease Outpatient Clinic in Harran University Research Hospital, Turkey between the period March 2006 and June 2006. We calculated the total antioxidant potential (TAOP) to determine the antioxidative status of plasma and we measured the total peroxide levels to determine the oxidative status of plasma. The TAOP of plasma was significantly lower in patients with COPD than in healthy smokers and healthy non-smokers (p< 0.001). In contrast, the mean total peroxide level of plasma was significantly higher in COPD patients than in healthy smokers and healthy non-smokers (p<0.001). We found a decreased in TAOP COPD patients using a simple, rapid and reliably automated colorimetric assay, which may suitable for use in routine clinical biochemistry laboratory and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow-up the levels of oxidative stress in COPD. (author)
Impact of automation on mass spectrometry.
Zhang, Yan Victoria; Rockwood, Alan
2015-10-23
Mass spectrometry coupled to liquid chromatography (LC-MS and LC-MS/MS) is an analytical technique that has rapidly grown in popularity in clinical practice. In contrast to traditional technology, mass spectrometry is superior in many respects including resolution, specificity, multiplex capability and has the ability to measure analytes in various matrices. Despite these advantages, LC-MS/MS remains high cost, labor intensive and has limited throughput. This specialized technology requires highly trained personnel and therefore has largely been limited to large institutions, academic organizations and reference laboratories. Advances in automation will be paramount to break through this bottleneck and increase its appeal for routine use. This article reviews these challenges, shares perspectives on essential features for LC-MS/MS total automation and proposes a step-wise and incremental approach to achieve total automation through reducing human intervention, increasing throughput and eventually integrating the LC-MS/MS system into the automated clinical laboratory operations. Copyright © 2015 Elsevier B.V. All rights reserved.
Cost challenges for laboratory medicine automation in Africa
Directory of Open Access Journals (Sweden)
Donald Moshen Tanyanyiwa
2010-09-01
Full Text Available Automation in laboratory medicine is inevitable and the only way forward especially in Africa where the staff turnover is high due to migration of experienced staff to Europe and America. Described here are the common issues that laboratory Managers and Directors encounter when upgrading, replacing analytical systems as well as daily running of diagnostic laboratories. The rapid advancement driven by the first world where research facilities, resources and expertise are available has seen changes in the both the hardware and software utilised by analyzers every two to three years. The downside is that in the process of replacing/phasing out old analysers, the first world countries in some cases donate them to second and third world countries as refurbished analysers. Problems in obtaining spares ensue since the production of new analysers results in reduced production or even of old spares. Unavailability or delayed availability of spares results in suspension of diagnostic service by the recipient laboratory. In some areas costly modifications to the analysers or the location/building have had to done to suite local (African conditions, hence the need for Laboratory managers to understand fully the analysers’ operational requirements before purchasing or accepting donations
Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.
Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan
2017-12-22
To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Fully automated laboratory for the assay of plutonium in wastes and recoverable scraps
International Nuclear Information System (INIS)
Guiberteau, P.; Michaut, F.; Bergey, C.; Debruyne, T.
1990-01-01
To determine the plutonium content of wastes and recoverable scraps in intermediate size containers (ten liters) an automated laboratory has been carried out. Two passive methods of measurement are used. Gamma ray spectrometry allows plutonium isotopic analysis, americium determination and plutonium assay in wastes and poor scraps. Calorimetry is used for accurate (± 3%) plutonium determination in rich scraps. A full automation was realized with a barcode management and a supply robot to feed the eight assay set-ups. The laboratory works on a 24 hours per day and 365 days per year basis and has a capacity of 8,000 assays per year
International Nuclear Information System (INIS)
Morris, W.F.; Fisher, E.R.; Barton, G.W. Jr.
1978-01-01
The feasibility of automating the analytical laboratories of the Chemistry Branch of the National Enforcement Investigation Center, Environmental Protection Agency, Denver, Colorado, is explored. The goals of the chemistry laboratory are defined, and instrumental methods and other tasks to be automated are described. Five optional automation systems are proposed to meet these goals and the options are evaluated in terms of cost effectiveness and other specified criteria. The instruments to be automated include (1) a Perkin-Elmer AA spectrophotometer 403, (2) Perkin-Elmer AA spectrophotometer 306, (3) Technicon AutoAnalyzer II, (4) Mettler electronic balance, and a (5) Jarrell-Ash ICP emission spectrometer
International Nuclear Information System (INIS)
Morris, W.F.; Peck, E.S.; Fisher, E.R.; Barton, G.W. Jr.
1976-01-01
This study of the feasibility of further automating the Central Laboratories deals specifically with the combined laboratory operations in Salt Lake City, Utah, and Denver, Colorado and is prepared with the understanding that such a system will also be implemented at the Central Laboratories in Atlanta, Georgia, and Albany, New York. The goals of automation are defined in terms of the mission of a water analysis laboratory, propose alternative computer systems for meeting such goals, and evaluate these alternatives in terms of cost effectiveness and other specified criteria. It is found that further automation will be beneficial and an in-house system that incorporates dual minicomputers is recommended: one for time-shared data acquisition, processing, and control; the second for data management. High-use analytical instruments are placed on-line to the time-shared minicomputer, with a terminal at each instrument and backup data storage on magnetic tape. A third, standby computer is switched in manually should the time-shared computer go down. Field-proven, modular hardware and software are chosen. Also recommended is the incorporation of the highly developed, computer-integrated instruments that are commercially available for determining petrochemicals and other organic substances, and are essential to the Laboratories' mission
Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja
2018-02-23
The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.
Camporese, Alessandro
2004-06-01
The diagnosis of infectious diseases and the role of the microbiology laboratory are currently undergoing a process of change. The need for overall efficiency in providing results is now given the same importance as accuracy. This means that laboratories must be able to produce quality results in less time with the capacity to interpret the results clinically. To improve the clinical impact of microbiology results, the new challenge facing the microbiologist has become one of process management instead of pure analysis. A proper project management process designed to improve workflow, reduce analytical time, and provide the same high quality results without losing valuable time treating the patient, has become essential. Our objective was to study the impact of introducing automation and computerization into the microbiology laboratory, and the reorganization of the laboratory workflow, i.e. scheduling personnel to work shifts covering both the entire day and the entire week. In our laboratory, the introduction of automation and computerization, as well as the reorganization of personnel, thus the workflow itself, has resulted in an improvement in response time and greater efficiency in diagnostic procedures.
Flow injection analysis: Emerging tool for laboratory automation in radiochemistry
International Nuclear Information System (INIS)
Egorov, O.; Ruzicka, J.; Grate, J.W.; Janata, J.
1996-01-01
Automation of routine and serial assays is a common practice of modern analytical laboratory, while it is virtually nonexistent in the field of radiochemistry. Flow injection analysis (FIA) is a general solution handling methodology that has been extensively used for automation of routine assays in many areas of analytical chemistry. Reproducible automated solution handling and on-line separation capabilities are among several distinctive features that make FI a very promising, yet under utilized tool for automation in analytical radiochemistry. The potential of the technique is demonstrated through the development of an automated 90 Sr analyzer and its application in the analysis of tank waste samples from the Hanford site. Sequential injection (SI), the latest generation of FIA, is used to rapidly separate 90 Sr from interfering radionuclides and deliver separated Sr zone to a flow-through liquid scintillation detector. The separation is performed on a mini column containing Sr-specific sorbent extraction material, which selectively retains Sr under acidic conditions. The 90 Sr is eluted with water, mixed with scintillation cocktail, and sent through the flow cell of a flow through counter, where 90 Sr radioactivity is detected as a transient signal. Both peak area and peak height can be used for quantification of sample radioactivity. Alternatively, stopped flow detection can be performed to improve detection precision for low activity samples. The authors current research activities are focused on expansion of radiochemical applications of FIA methodology, with an ultimate goal of creating a set of automated methods that will cover the basic needs of radiochemical analysis at the Hanford site. The results of preliminary experiments indicate that FIA is a highly suitable technique for the automation of chemically more challenging separations, such as separation of actinide elements
Iglehart, Brian
2018-05-01
Laboratory automation improves test reproducibility, which is vital to patient care in clinical laboratories. Many small and specialty laboratories are excluded from the benefits of automation due to low sample number, cost, space, and/or lack of automation expertise. The Minimum Viable Option (MVO) automation platform was developed to address these hurdles and fulfill an unmet need. Consumer 3D printing enabled rapid iterative prototyping to allow for a variety of instrumentation and assay setups and procedures. Three MVO versions have been produced. MVOv1.1 successfully performed part of a clinical assay, and results were comparable to those of commercial automation. Raspberry Pi 3 Model B (RPI3) single-board computers with Sense Hardware Attached on Top (HAT) and Raspberry Pi Camera Module V2 hardware were remotely accessed and evaluated for their suitability to qualify the latest MVOv1.2 platform. Sense HAT temperature, barometric pressure, and relative humidity sensors were stable in climate-controlled environments and are useful in identifying appropriate laboratory spaces for automation placement. The RPI3 with camera plus digital dial indicator logged axis travel experiments. RPI3 with camera and Sense HAT as a light source showed promise when used for photometric dispensing tests. Individual well standard curves were necessary for well-to-well light and path length compensations.
Benchmarking Glucose Results through Automation: The 2009 Remote Automated Laboratory System Report
Anderson, Marcy; Zito, Denise; Kongable, Gail
2010-01-01
Background Hyperglycemia in the adult inpatient population remains a topic of intense study in U.S. hospitals. Most hospitals have established glycemic control programs but are unable to determine their impact. The 2009 Remote Automated Laboratory System (RALS) Report provides trends in glycemic control over 4 years to 576 U.S. hospitals to support their effort to manage inpatient hyperglycemia. Methods A proprietary software application feeds de-identified patient point-of-care blood glucose (POC-BG) data from the Medical Automation Systems RALS-Plus data management system to a central server. Analyses include the number of tests and the mean and median BG results for intensive care unit (ICU), non-ICU, and each hospital compared to the aggregate of the other hospitals. Results More than 175 million BG results were extracted from 2006–2009; 25% were from the ICU. Mean range of BG results for all inpatients in 2006, 2007, 2008, and 2009 was 142.2–201.9, 145.6–201.2, 140.6–205.7, and 140.7–202.4 mg/dl, respectively. The range for ICU patients was 128–226.5, 119.5–219.8, 121.6–226.0, and 121.1–217 mg/dl, respectively. The range for non-ICU patients was 143.4–195.5, 148.6–199.8, 145.2–201.9, and 140.7–203.6 mg/dl, respectively. Hyperglycemia rates of >180 mg/dl in 2008 and 2009 were examined, and hypoglycemia rates of Automated POC-BG data management software can assist in this effort. PMID:21129348
Large-scale automation of the Lawrence Livermore Laboratory x-ray analytical facilities
International Nuclear Information System (INIS)
Wallace, P.L.; Shimamoto, F.Y.; Quick, T.M.
1980-01-01
Lawrence Livermore Laboratory (LLL) has undertaken an ambitious plan to automate its x-ray analytical equipment. This project ultimately will automate 15 x-ray diffraction and 3 x-ray spectrometric systems. All automation is being done by retrofitting existing equipment and combining it with minicomputers to produce smart instruments. Two types of smart instruments have been developed: one that controls an experiment and acquires data and another that analyzes data and communicates with LLL's large computer center. Three of the former type have been built and are operating; seven more will soon be put into service. Only two of the later type are needed, and both are currently in service. We describe the details of our overall plan, the smart instruments, the retrofitting, our current status, and our software
Medical record automation at the Los Alamos Scientific Laboratory
International Nuclear Information System (INIS)
Hogle, G.O.; Grier, R.S.
1979-01-01
With the increase in population at the Los Alamos Scientific Laboratory and the growing concern over employee health, especially concerning the effects of the work environment, the Occupational Medicine Group decided to automate its medical record keeping system to meet these growing demands. With this computer system came not only the ability for long-term study of the work environment verses employee health, but other benefits such as more comprehensive records, increased legibility, reduced physician time, and better records management
On-line analysis of biosignals for the automation of total and specific sleep deprivation in the rat
Directory of Open Access Journals (Sweden)
ENNIO A VIVALDI
2008-12-01
Full Text Available A computer-based system that automates sleep studies, including sleep deprivation paradigms, is described. The system allows for total or REM-specific sleep deprivation and is based on a reliable, fast-responding, on-line state detection algorithm linked to a dependable intervention device. Behavioral state detection is achieved by dimensión reduction of short-term EEG power spectrum. Interventions are made by serial outputs to servomotors that move a cage with different patterns and variable intensity. The system can adapt itself to individual characteristics and to changes in recording conditions. Customized protocols can be designed by defining the states or stages to be deprived, including scheduling temporal patterns. A detailed analysis of the relevant signáis during and after deprivation is readily available. Data is presented from two experimental designs in rats. One consisted of specific REM-sleep short-term deprivation and the other of 10-hour total sleep deprivation. An outline of conceptual and practical considerations involved in the automation of laboratory set-ups oriented to biosignal analysis is provided. Careful monitoring of sleep EEG variables during sleep deprivation suggests peculiarities of brain functioning in that condition. A corollary is that sleep deprivation should not be considered to be merely a forced prolonged wakefulness.
Does laboratory automation for the preanalytical phase improve data quality?
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Danese, Elisa; Montagnana, Martina; Brocco, Giorgio; Voi, Monica; Picheth, Geraldo; Guidi, Gian Cesare
2013-10-01
Our aim was to evaluate whether automation for the preanalytical phase improves data quality. Blood from 100 volunteers was collected into two vacuum tubes. One sample from each volunteer was respectively assigned to (G1) traditional processing, starting with centrifugation at 1200 g for 10 min, and (G2) the MODULAR PRE-ANALYTICALS EVO-MPA system. The routine clinical chemistry tests were performed in duplicate on the same instrument Cobas 6000 module. G1 samples were uncapped manually and immediately placed into the instrument. G2 samples were directly fed from the MPA system to the instrument without further staff intervention. At the end, (1) the G1 samples were stored for 6 h at 4 °C as prescribed in our accredited laboratory and (2) the G2 samples were stored for 6 h in the MPA output buffer. Results from G1 and G2, before and after storage, were compared. Significant increases were observed in G1 compared with G2 samples as follows: (1) before storage for alkaline phosphatase (ALP), lactate dehydrogenase (LDH), phosphate (P), magnesium (MG), iron (FE), and hemolysis index and (2) after storage for total cholesterol (COL), triglycerides (TG), total protein (TP), albumin (ALB), blood urea nitrogen (BUN), creatinine (CRE), uric acid (UA), ALP, pancreatic amylase, aspartate aminotransferase (AST), alanine aminotransferase (ALT), g-glutamyltransferase (GGT), LDH, creatine kinase (CK), calcium (CA), FE, sodium (NA), potassium (K), and hemolysis index. Moreover, significant increases were observed in (3) G1-after versus G1-before storage samples for COL, high-density lipoprotein cholesterol, TG, TP, ALB, BUN, CRE, UA, AST, ALT, GGT, LDH, P, CA, MG, FE, NA, K, and hemolysis index and (4) G2-after versus G2-before storage only for BUN, AST, LDH, P, and CA. In conclusion, our results show that the MPA system improves the quality of laboratory testing.
[The actual possibilities of robotic microscopy in analysis automation and laboratory telemedicine].
Medovyĭ, V S; Piatnitskiĭ, A M; Sokolinskiĭ, B Z; Balugian, R Sh
2012-10-01
The article discusses the possibilities of automation microscopy complexes manufactured by Cellavision and MEKOS to perform the medical analyses of blood films and other biomaterials. The joint work of the complex and physician in the regimen of automatic load stages, screening, sampling and sorting on types with simple morphology, visual sorting of sub-sample with complex morphology provides significant increase of method sensitivity, load decrease and enhancement of physician work conditions. The information technologies, the virtual slides and laboratory telemedicine included permit to develop the representative samples of rare types and pathologies to promote automation methods and medical research targets.
An automated image analysis system to measure and count organisms in laboratory microcosms.
Directory of Open Access Journals (Sweden)
François Mallard
Full Text Available 1. Because of recent technological improvements in the way computer and digital camera perform, the potential use of imaging for contributing to the study of communities, populations or individuals in laboratory microcosms has risen enormously. However its limited use is due to difficulties in the automation of image analysis. 2. We present an accurate and flexible method of image analysis for detecting, counting and measuring moving particles on a fixed but heterogeneous substrate. This method has been specifically designed to follow individuals, or entire populations, in experimental laboratory microcosms. It can be used in other applications. 3. The method consists in comparing multiple pictures of the same experimental microcosm in order to generate an image of the fixed background. This background is then used to extract, measure and count the moving organisms, leaving out the fixed background and the motionless or dead individuals. 4. We provide different examples (springtails, ants, nematodes, daphnia to show that this non intrusive method is efficient at detecting organisms under a wide variety of conditions even on faintly contrasted and heterogeneous substrates. 5. The repeatability and reliability of this method has been assessed using experimental populations of the Collembola Folsomia candida. 6. We present an ImageJ plugin to automate the analysis of digital pictures of laboratory microcosms. The plugin automates the successive steps of the analysis and recursively analyses multiple sets of images, rapidly producing measurements from a large number of replicated microcosms.
Energy Technology Data Exchange (ETDEWEB)
Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)
2013-02-15
To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume ({gamma}= 0.637 for total liver and {gamma}= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.
International Nuclear Information System (INIS)
Shin, Cheong Il; Kim, Se Hyung; Rhim, Jung Hyo; Yi, Nam Joon; Suh, Kyung Suk; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn
2013-01-01
To assess the feasibility of commercially-available, fully automated hepatic CT volumetry for measuring both total and territorial liver volumes by comparing with interactive manual volumetry and measured ex-vivo liver volume. For the assessment of total and territorial liver volume, portal phase CT images of 77 recipients and 107 donors who donated right hemiliver were used. Liver volume was measured using both the fully automated and interactive manual methods with Advanced Liver Analysis software. The quality of the automated segmentation was graded on a 4-point scale. Grading was performed by two radiologists in consensus. For the cases with excellent-to-good quality, the accuracy of automated volumetry was compared with interactive manual volumetry and measured ex-vivo liver volume which was converted from weight using analysis of variance test and Pearson's or Spearman correlation test. Processing time for both automated and interactive manual methods was also compared. Excellent-to-good quality of automated segmentation for total liver and right hemiliver was achieved in 57.1% (44/77) and 17.8% (19/107), respectively. For both total and right hemiliver volumes, there were no significant differences among automated, manual, and ex-vivo volumes except between automate volume and manual volume of the total liver (p = 0.011). There were good correlations between automate volume and ex-vivo liver volume (γ= 0.637 for total liver and γ= 0.767 for right hemiliver). Both correlation coefficients were higher than those with manual method. Fully automated volumetry required significantly less time than interactive manual method (total liver: 48.6 sec vs. 53.2 sec, right hemiliver: 182 sec vs. 244.5 sec). Fully automated hepatic CT volumetry is feasible and time-efficient for total liver volume measurement. However, its usefulness for territorial liver volumetry needs to be improved.
Day, Molly A; Anthony, Christopher A; Bedard, Nicholas A; Glass, Natalie A; Clark, Charles R; Callaghan, John J; Noiseux, Nicolas O
2018-01-01
Automated mobile phone messaging has not been reported in total joint arthroplasty (TJA). Our purpose was to compare Press Ganey (PG) and Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) scores between TJA patients who did and did not receive perioperative automated mobile phone messages. Patients were prospectively enrolled and received messages for 1 week prior until 2 weeks after TJA. Message content included reminders, activity, and pain control. Patients answered select PG/HCAHPS and questions regarding their experience with the automated communication platform. Average PG/HCAHPS scores were compared to historical TJA patients in the 3-year window prior (control group) with significance P communication via automated mobile phone messaging had improved patient satisfaction scores postoperatively. Patients perceived this form of communication was useful and kept them better informed. Automated mobile phone messaging can be an easily integrated, helpful adjunct to surgeons, healthcare systems, and case managers to more effectively communicate with patients undergoing TJA in this era of value-based care. Copyright © 2017 Elsevier Inc. All rights reserved.
Eddy current technique applied to automated tube profilometry
International Nuclear Information System (INIS)
Dobbeni, D.; Melsen, C. van
1982-01-01
The use of eddy current methods in the first totally automated pre-service inspection of the internal diameter of PWR steam generator tubes is described. The technique was developed at Laborelec, the Belgian Laboratory of the Electricity Supply Industry. Details are given of the data acquisition system and of the automated manipulator. Representative tube profiles are illustrated. (U.K.)
A new automated colorimetric method for measuring total oxidant status.
Erel, Ozcan
2005-12-01
To develop a new, colorimetric and automated method for measuring total oxidation status (TOS). The assay is based on the oxidation of ferrous ion to ferric ion in the presence of various oxidant species in acidic medium and the measurement of the ferric ion by xylenol orange. The oxidation reaction of the assay was enhanced and precipitation of proteins was prevented. In addition, autoxidation of ferrous ion present in the reagent was prevented during storage. The method was applied to an automated analyzer, which was calibrated with hydrogen peroxide and the analytical performance characteristics of the assay were determined. There were important correlations with hydrogen peroxide, tert-butyl hydroperoxide and cumene hydroperoxide solutions (r=0.99, Ptotal antioxidant capacity (TAC) (r=-0.66 Ptotal oxidant status.
Automation at NRCN Dosimetry Laboratory
International Nuclear Information System (INIS)
Abraham, A.; Arad, I.; Mesing, M.; Levinson, S.; Weinstein, M.; Pelled, O.; Broida, A.; German, U.
2014-01-01
Running a dosimetric service based on TLD technology such as at the Nuclear Research Centre Negev (NRCN) requires a large group of workers to carry out simple mechanical actions such as opening and closing TLD badges, placing and removal of TLD cards from the badges and operating the TLD reader. These actions can be automated to free human resources for other assignments and to improve the quality assurance. At NRCN a project was undertaken to design and build a robotic system based on a manipulator arm. The design was based on the experience achieved with an earlier prototype (1,2). The system stores the TLD badges in special designed boxes, which are transported and stored in computer defined bins. The robotic arm loads and unloads TLD cards to the badges, and loads/unloads the cards to a magazine for the TLD reader. At the Nuclear Research Center Negev (NRCN) each badge is assigned to a specific worker and bears a sticker containing the worker's personal details, also in a machine readable form (barcode). In order to establish a proper QA check, a barcode reader records the information on the badge and on the TLD card placed in this badge and checks their compatibility with the information contained in the main database. Besides the TLD cards loading/unloading station, there is a contamination check station, a cards cleaning station and a UV irradiation box used to reduce the history dependent residual dose. The system was installed at the NRCN dosimetry laboratory It was successfully tested for several hundreds of cycles and will become operational in the first quarter of 2014. As far as we know, there is no similar product available for automatic handling in a TLD laboratory
Hawker, Charles D; Roberts, William L; Garr, Susan B; Hamilton, Leslie T; Penrose, John R; Ashwood, Edward R; Weiss, Ronald L
2002-10-01
Our laboratory implemented a major automation system in November 1998. A related report describes a 4-year process of evaluation and planning leading to system installation. This report describes the implementation and performance results over 3 years since the system was placed into use. Project management software was used to track the project. Turnaround times of our top 500 tests before and after automation were measured. We compared the rate of hiring of employees and the billed unit per employee ratio before and after automation by use of linear regression analysis. Finally, we analyzed the financial contribution of the project through an analysis of return on investment. Since implementation, the volume of work transported and sorted has grown to >15,000 new tubes and >25,000 total tubes per day. Median turnaround time has decreased by an estimated 7 h, and turnaround time at the 95th percentile has decreased by 12 h. Lost specimens have decreased by 58%. A comparison of pre- and post-implementation hiring rates of employees estimated a savings of 33.6 employees, whereas a similar comparison of ratios of billed units per employee estimated a savings of 49.1 employees. Using the higher figure, we estimated that the $4.02 million cost of the project would be paid off approximately 4.9 years subsequent to placing the system into daily use. The overall automation project implemented in our laboratory has contributed considerably to improvement of key performance measures and has met our original project objectives.
A new fully automated FTIR system for total column measurements of greenhouse gases
Geibel, M. C.; Gerbig, C.; Feist, D. G.
2010-10-01
This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON). It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control. First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.
ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study
Directory of Open Access Journals (Sweden)
Stefanie Van den Bremt
2017-01-01
Full Text Available Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA indirect immunofluorescence (IIF analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.
USB port compatible virtual instrument based automation for x-ray diffractometer setup
International Nuclear Information System (INIS)
Jayapandian, J.; Sheela, O.K.; Mallika, R.; Thiruarul, A.; Purniah, B.
2004-01-01
Windows based virtual instrument (VI) programs in graphic language simplify the design automation in R and D laboratories. With minimal hardware and maximum support of software, the automation becomes easier and user friendly. A novel design approach for the automation of SIEMENS make x-ray diffractometer setup is described in this paper. The automation is achieved with an indigenously developed virtual instrument program in labVIEW ver.6.0 and with a simple hardware design using 89C2051 micro-controller compatible with PC's USB port for the total automation of the experiment. (author)
Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan
2005-11-11
Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p total peroxide level and mean oxidative stress index were higher (all p total peroxide level, total antioxidant response and oxidative stress index (p 0.05). Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.
Automated Scheduling of Personnel to Staff Operations for the Mars Science Laboratory
Knight, Russell; Mishkin, Andrew; Allbaugh, Alicia
2014-01-01
Leveraging previous work on scheduling personnel for space mission operations, we have adapted ASPEN (Activity Scheduling and Planning Environment) [1] to the domain of scheduling personnel for operations of the Mars Science Laboratory. Automated scheduling of personnel is not new. We compare our representations to a sampling of employee scheduling systems available with respect to desired features. We described the constraints required by MSL personnel schedulers and how each is handled by the scheduling algorithm.
Evaluation of automated analysis of 15N and total N in plant material and soil
DEFF Research Database (Denmark)
Jensen, E.S.
1991-01-01
Simultaneous determination of N-15 and total N using an automated nitrogen analyser interfaced to a continuous-flow isotope ratio mass spectrometer (ANA-MS method) was evaluated. The coefficient of variation (CV) of repeated analyses of homogeneous standards and samples at natural abundance...... was lower than 0.1%. The CV of repeated analyses of N-15-labelled plant material and soil samples varied between 0.3% and 1.1%. The reproducibility of repeated total N analyses using the automated method was comparable to results obtained with a semi-micro Kjeldahl procedure. However, the automated method...... analysis showed that the recovery of inorganic N in the NH3 trap was lower when the N was diffused from water than from 2 M KCl. The results also indicated that different proportions of the NO3- and the NH4+ in aqueous solution were recovered in the trap after combined diffusion. The method is most suited...
Automated blood-sample handling in the clinical laboratory.
Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O
1990-09-01
The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.
Ask the experts: automation: part I.
Allinson, John L; Blick, Kenneth E; Cohen, Lucinda; Higton, David; Li, Ming
2013-08-01
Bioanalysis invited a selection of leading researchers to express their views on automation in the bioanalytical laboratory. The topics discussed include the challenges that the modern bioanalyst faces when integrating automation into existing drug-development processes, the impact of automation and how they envision the modern bioanalytical laboratory changing in the near future. Their enlightening responses provide a valuable insight into the impact of automation and the future of the constantly evolving bioanalytical laboratory.
A new fully automated FTIR system for total column measurements of greenhouse gases
Directory of Open Access Journals (Sweden)
M. C. Geibel
2010-10-01
Full Text Available This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON. It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics.
Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control.
First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months.
After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.
The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.
Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver
2017-02-01
Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.
International Nuclear Information System (INIS)
Christensen, L.J.; Sackett, J.I.; Dayal, Y.; Wagner, W.K.
1989-01-01
This paper describes work at EBR-II in the development and demonstration of new control equipment and methods and associated schemes for plant prognosis, diagnosis, and automation. The development work has attracted the interest of other national laboratories, universities, and commercial companies. New initiatives include use of new control strategies, expert systems, advanced diagnostics, and operator displays. The unique opportunity offered by EBR-II is as a test bed where a total integrated approach to automatic reactor control can be directly tested under real power plant conditions
A Remote PLC Laboratory (RLab) for Distance Practical Work of Industrial Automation
Haritman, E.; Somantri, Y.; Wahyudin, D.; Mulyana, E.
2018-02-01
A laboratory is an essential equipment for engineering students to do a useful practical work. Therefore, universities should provide an adequate facility for practical work. On the other hand, industrial automation laboratory would offer students beneficial experience by using various educational PLC kits. This paper describes the development of Web-based Programmable Logic Controller (PLC) remote laboratory called RLab. It provides an environment for learners to study PLC application to control the level of the non-interacting tank. The RLab architecture is based on a Moodle and Remote Desktop, which also manages the booking system of the schedule of practical work in the laboratory. The RLab equipped by USB cameras providing a real-time view of PLC environment. To provide a secured system, the RLab combines Moodle and Remote Desktop application for the authentication system and management of remote users. Moodle will send PartnerID and password to connect to TeamViewer. It has been examined that the laboratory requirement, time and flexibility restrictions constitute a significant obstacle facing traditional students desiring to finish the course. A remote access laboratory can be eliminating time and flexibility restrictions. The preliminary study of RLab usability proved that such system is adequate to give the learners a distance practical work environment.
Automation of multiple neutral beam injector controls at Lawrence Livermore Laboratory
International Nuclear Information System (INIS)
Pollock, G.G.
1977-01-01
The computer control system used on the twelve Neutral Beams of the 2XIIB experiment at the Lawrence Livermore Laboratory (LLL) has evolved over the last three years. It is now in its final form and in regular use. It provides automatic data collection, reduction, and graphics presentation, as well as automatic conditioning, automatic normal operation, and processing of calorimeter data. This paper presents an overview of the capabilities and implementation of the current system, a detailed discussion of the automatic conditioning algorithm, and discusses the future directions for neutral beam automation
Evaluation of an automated struvite reactor to recover phosphorus ...
African Journals Online (AJOL)
In the present study we attempted to develop a reactor system to recover phosphorus by struvite precipitation, and which can be installed anywhere in the field without access to a laboratory. A reactor was developed that can run fully automated and recover up to 93% of total phosphorus (total P). Turbidity and conductivity ...
Directory of Open Access Journals (Sweden)
Sarifakiogullari Serpil
2005-11-01
Full Text Available Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Results Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p In subjects with nonalcoholic steatohepatitis, fibrosis score was significantly correlated with total peroxide level, total antioxidant response and oxidative stress index (p 0.05. Conclusion Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.
Harms, Justin D.; Bachmann, Charles M.; Ambeau, Brittany L.; Faulring, Jason W.; Ruiz Torres, Andres J.; Badura, Gregory; Myers, Emily
2017-10-01
Field-portable goniometers are created for a wide variety of applications. Many of these applications require specific types of instruments and measurement schemes and must operate in challenging environments. Therefore, designs are based on the requirements that are specific to the application. We present a field-portable goniometer that was designed for measuring the hemispherical-conical reflectance factor (HCRF) of various soils and low-growing vegetation in austere coastal and desert environments and biconical reflectance factors in laboratory settings. Unlike some goniometers, this system features a requirement for "target-plane tracking" to ensure that measurements can be collected on sloped surfaces, without compromising angular accuracy. The system also features a second upward-looking spectrometer to measure the spatially dependent incoming illumination, an integrated software package to provide full automation, an automated leveling system to ensure a standard frame of reference, a design that minimizes the obscuration due to self-shading to measure the opposition effect, and the ability to record a digital elevation model of the target region. This fully automated and highly mobile system obtains accurate and precise measurements of HCRF in a wide variety of terrain and in less time than most other systems while not sacrificing consistency or repeatability in laboratory environments.
Isoda, Yuta; Sasaki, Norihiko; Kitamura, Kei; Takahashi, Shuji; Manmode, Sujit; Takeda-Okuda, Naoko; Tamura, Jun-Ichi; Nokami, Toshiki; Itoh, Toshiyuki
2017-01-01
The total synthesis of TMG-chitotriomycin using an automated electrochemical synthesizer for the assembly of carbohydrate building blocks is demonstrated. We have successfully prepared a precursor of TMG-chitotriomycin, which is a structurally-pure tetrasaccharide with typical protecting groups, through the methodology of automated electrochemical solution-phase synthesis developed by us. The synthesis of structurally well-defined TMG-chitotriomycin has been accomplished in 10-steps from a disaccharide building block.
Directory of Open Access Journals (Sweden)
Yuta Isoda
2017-05-01
Full Text Available The total synthesis of TMG-chitotriomycin using an automated electrochemical synthesizer for the assembly of carbohydrate building blocks is demonstrated. We have successfully prepared a precursor of TMG-chitotriomycin, which is a structurally-pure tetrasaccharide with typical protecting groups, through the methodology of automated electrochemical solution-phase synthesis developed by us. The synthesis of structurally well-defined TMG-chitotriomycin has been accomplished in 10-steps from a disaccharide building block.
Contaminant analysis automation, an overview
International Nuclear Information System (INIS)
Hollen, R.; Ramos, O. Jr.
1996-01-01
To meet the environmental restoration and waste minimization goals of government and industry, several government laboratories, universities, and private companies have formed the Contaminant Analysis Automation (CAA) team. The goal of this consortium is to design and fabricate robotics systems that standardize and automate the hardware and software of the most common environmental chemical methods. In essence, the CAA team takes conventional, regulatory- approved (EPA Methods) chemical analysis processes and automates them. The automation consists of standard laboratory modules (SLMs) that perform the work in a much more efficient, accurate, and cost- effective manner
Shackelford, Stacy; Yang, Shiming; Hu, Peter; Miller, Catriona; Anazodo, Amechi; Galvagno, Samuel; Wang, Yulei; Hartsky, Lauren; Fang, Raymond; Mackenzie, Colin
2015-10-01
Identification of hemorrhaging trauma patients and prediction of blood transfusion needs in near real time will expedite care of the critically injured. We hypothesized that automated analysis of pulse oximetry signals in combination with laboratory values and vital signs obtained at the time of triage would predict the need for blood transfusion with accuracy greater than that of triage vital signs or pulse oximetry analysis alone. Continuous pulse oximetry signals were recorded for directly admitted trauma patients with abnormal prehospital shock index (heart rate [HR] / systolic blood pressure) of 0.62 or greater. Predictions of blood transfusion within 24 hours were compared using Delong's method for area under the receiver operating characteristic (AUROC) curves to determine the optimal combination of triage vital signs (prehospital HR + systolic blood pressure), pulse oximetry features (40 waveform features, O2 saturation, HR), and laboratory values (hematocrit, electrolytes, bicarbonate, prothrombin time, international normalization ratio, lactate) in multivariate logistic regression models. We enrolled 1,191 patients; 339 were excluded because of incomplete data; 40 received blood within 3 hours; and 14 received massive transfusion. Triage vital signs predicted need for transfusion within 3 hours (AUROC, 0.59) and massive transfusion (AUROC, 0.70). Pulse oximetry for 15 minutes predicted transfusion more accurately than triage vital signs for both time frames (3-hour AUROC, 0.74; p = 0.004) (massive transfusion AUROC, 0.88; p transfusion prediction (3-hour AUROC, 0.84; p transfusion AUROC, 0.91; p blood transfusion during trauma resuscitation more accurately than triage vital signs or pulse oximetry analysis alone. Results suggest automated calculations from a noninvasive vital sign monitor interfaced with a point-of-care laboratory device may support clinical decisions by recognizing patients with hemorrhage sufficient to need transfusion. Epidemiologic
MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.
Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang
2005-01-01
MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.
Automated CT-based segmentation and quantification of total intracranial volume
Energy Technology Data Exchange (ETDEWEB)
Aguilar, Carlos; Wahlund, Lars-Olof; Westman, Eric [Karolinska Institute, Department of Neurobiology, Care Sciences and Society (NVS), Division of Clinical Geriatrics, Stockholm (Sweden); Edholm, Kaijsa; Cavallin, Lena; Muller, Susanne; Axelsson, Rimma [Karolinska Institute, Department of Clinical Science, Intervention and Technology, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Simmons, Andrew [King' s College London, Institute of Psychiatry, London (United Kingdom); NIHR Biomedical Research Centre for Mental Health and Biomedical Research Unit for Dementia, London (United Kingdom); Skoog, Ingmar [Gothenburg University, Department of Psychiatry and Neurochemistry, The Sahlgrenska Academy, Gothenburg (Sweden); Larsson, Elna-Marie [Uppsala University, Department of Surgical Sciences, Radiology, Akademiska Sjukhuset, Uppsala (Sweden)
2015-11-15
To develop an algorithm to segment and obtain an estimate of total intracranial volume (tICV) from computed tomography (CT) images. Thirty-six CT examinations from 18 patients were included. Ten patients were examined twice the same day and eight patients twice six months apart (these patients also underwent MRI). The algorithm combines morphological operations, intensity thresholding and mixture modelling. The method was validated against manual delineation and its robustness assessed from repeated imaging examinations. Using automated MRI software, the comparability with MRI was investigated. Volumes were compared based on average relative volume differences and their magnitudes; agreement was shown by a Bland-Altman analysis graph. We observed good agreement between our algorithm and manual delineation of a trained radiologist: the Pearson's correlation coefficient was r = 0.94, tICVml[manual] = 1.05 x tICVml[automated] - 33.78 (R{sup 2} = 0.88). Bland-Altman analysis showed a bias of 31 mL and a standard deviation of 30 mL over a range of 1265 to 1526 mL. tICV measurements derived from CT using our proposed algorithm have shown to be reliable and consistent compared to manual delineation. However, it appears difficult to directly compare tICV measures between CT and MRI. (orig.)
Automated CT-based segmentation and quantification of total intracranial volume
International Nuclear Information System (INIS)
Aguilar, Carlos; Wahlund, Lars-Olof; Westman, Eric; Edholm, Kaijsa; Cavallin, Lena; Muller, Susanne; Axelsson, Rimma; Simmons, Andrew; Skoog, Ingmar; Larsson, Elna-Marie
2015-01-01
To develop an algorithm to segment and obtain an estimate of total intracranial volume (tICV) from computed tomography (CT) images. Thirty-six CT examinations from 18 patients were included. Ten patients were examined twice the same day and eight patients twice six months apart (these patients also underwent MRI). The algorithm combines morphological operations, intensity thresholding and mixture modelling. The method was validated against manual delineation and its robustness assessed from repeated imaging examinations. Using automated MRI software, the comparability with MRI was investigated. Volumes were compared based on average relative volume differences and their magnitudes; agreement was shown by a Bland-Altman analysis graph. We observed good agreement between our algorithm and manual delineation of a trained radiologist: the Pearson's correlation coefficient was r = 0.94, tICVml[manual] = 1.05 x tICVml[automated] - 33.78 (R 2 = 0.88). Bland-Altman analysis showed a bias of 31 mL and a standard deviation of 30 mL over a range of 1265 to 1526 mL. tICV measurements derived from CT using our proposed algorithm have shown to be reliable and consistent compared to manual delineation. However, it appears difficult to directly compare tICV measures between CT and MRI. (orig.)
Plasma input function determination for PET using a commercial laboratory robot
International Nuclear Information System (INIS)
Alexoff, David L.; Shea, Colleen; Fowler, Joanna S.; King, Payton; Gatley, S. John; Schlyer, David J.; Wolf, Alfred P.
1995-01-01
A commercial laboratory robot system (Zymate PyTechnology II Laboratory Automation System) was interfaced to standard and custom laboratory equipment and programmed to perform rapid radiochemical assays necessary for plasma input function determination in quantitative PET studies in humans and baboons. A Zymark XP robot arm was used to carry out two assays: (1) the determination of total plasma radioactivity concentrations in a series of small-volume whole blood samples and (2) the determination of unchanged (parent) radiotracer in plasma using only solid phase extraction methods. Steady state robotic throughput for determination of total plasma radioactivity in whole blood samples (0.350 mL) is 14.3 samples/h, which includes automated centrifugation, pipetting, weighing and radioactivity counting. Robotic throughput for the assay of parent radiotracer in plasma is 4-6 samples/h depending on the radiotracer. Percents of total radioactivities present as parent radiotracers at 60 min. postinjection of 25 ± 5.0 (N 25), 26 ± 6.8 (N = 68), 13 ± 4.4 (N = 30), 32 ± 7.2 (N = 18), 16 ± 4.9 (N = 20), were obtained for carbon-11 labeled benztropine, raclopride, methylphenidate, SR 46349B (trans, 4-[(3Z)3-(2-dimethylamino-ethyl) oxyimino-3 (2-fluorophenyl)propen-1-yl]phenol), and cocaine respectively in baboon plasma and 84 ± 6.4 (N = 9), 18 ± 11 (N = 10), 74 ± 5.7 (N = 118) and 16 ± 3.7 (N = 18) for carbon-11 labeled benztropine, deprenyl, raclopride, and methylphenidate respectively in human plasma. The automated system has been used for more than 4 years for all plasma analyses for 7 different C-11 labeled compounds used routinely in our laboratory. The robotic radiotracer assay runs unattended and includes automated cleanup procedures that eliminates all human contact with plasma-contaminated containers
Ti, Lian Kah; Ang, Sophia Bee Leng; Saw, Sharon; Sethi, Sunil Kumar; Yip, James W L
2012-08-01
Timely reporting and acknowledgement are crucial steps in critical laboratory results (CLR) management. The authors previously showed that an automated pathway incorporating short messaging system (SMS) texts, auto-escalation, and manual telephone back-up improved the rate and speed of physician acknowledgement compared with manual telephone calling alone. This study investigated if it also improved the rate and speed of physician intervention to CLR and whether utilising the manual back-up affected intervention rates. Data from seven audits between November 2007 and January 2011 were analysed. These audits were carried out to assess the robustness of CLR reporting process in the authors' institution. Comparisons were made in the rate and speed of acknowledgement and intervention between the audits performed before and after automation. Using the automation audits, the authors compared intervention data between communication with SMS only and when manual intervention was required. 1680 CLR were reported during the audit periods. Automation improved the rate (100% vs 84.2%; pautomation audits, the use of SMS only did not improve physician intervention rates. The automated communication pathway improved physician intervention rate and time in tandem with improved acknowledgement rate and time when compared with manual telephone calling. The use of manual intervention to augment automation did not adversely affect physician intervention rate, implying that an end-to-end pathway was more important than automation alone.
International Nuclear Information System (INIS)
Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc; Hart, A. John
2013-01-01
Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes
Energy Technology Data Exchange (ETDEWEB)
Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc [Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Hart, A. John, E-mail: ajhart@mit.edu [Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)
2013-11-15
Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes.
International Nuclear Information System (INIS)
Brandenburg, G.; Brocke, W.; Brodda, B.G.; Buerger, K.; Halling, H.; Heer, H.; Puetz, K.; Schaedlich, W.; Watzlawik, K.H.
1981-12-01
The essential tasks of the system are on-line open-loop process control based on in-line measurements and automation of the off-line analytical laboratory. The in-line measurements (at 55 tanks of the chemical process area) provide density-, liquid-, level-, and temperature values. The concentration value of a single component may easily be determined, if the solution consists of no more than two phases. The automation of the off-line analytical laboratory contains laboratory organization including sample management and data organization and computer-aided sample transportation control, data acquisition and data processing at chemical and nuclear analytical devices. The computer system consists of two computer-subsystems: a front end system for sample central registration and in-line process control and a central size system for the off-line analytical tasks. The organization of the application oriented system uses a centralized data base. Similar data processing functions concerning different analytical management tasks are structured into the following subsystem: man machine interface, interrupt- and data acquisition system, data base, protocol service and data processing. The procedures for the laboratory management (organization and experiment sequences) are defined by application data bases. Following the project phases, engineering requirements-, design-, assembly-, start up- and test run phase are described. In addition figures on expenditure and experiences are given and the system concept is discussed. (orig./HP) [de
International Nuclear Information System (INIS)
1992-01-01
An Advanced Automated Radiation Laboratory was completed; the hardware and software bases are now suitable for up-to-date kinetical measurements in radiation chemistry and technology both for Hungarian experts and for specialists from abroad. It would be possible and useful e.g. to organize further training courses in the field of radiation chemistry and technology by the IAEA and/or the UNDP, as well as to send fellows from developing countries for practical research work or other purposes (TCDC)
Lin, Shu-Wen; Kang, Wen-Yi; Lin, Dong-Tsamn; Lee, James; Wu, Fe-Lin; Chen, Chuen-Liang; Tseng, Yufeng J
2014-01-01
Computerized alert and reminder systems have been widely accepted and applied to various patient care settings, with increasing numbers of clinical laboratories communicating critical laboratory test values to professionals via either manual notification or automated alerting systems/computerized reminders. Warfarin, an oral anticoagulant, exhibits narrow therapeutic range between treatment response and adverse events. It requires close monitoring of prothrombin time (PT)/international normalized ratio (INR) to ensure patient safety. This study was aimed to evaluate clinical outcomes of patients on warfarin therapy following implementation of a Personal Handy-phone System-based (PHS) alert system capable of generating and delivering text messages to communicate critical PT/INR laboratory results to practitioners' mobile phones in a large tertiary teaching hospital. A retrospective analysis was performed comparing patient clinical outcomes and physician prescribing behavior following conversion from a manual laboratory result alert system to an automated system. Clinical outcomes and practitioner responses to both alert systems were compared. Complications to warfarin therapy, warfarin utilization, and PT/INR results were evaluated for both systems, as well as clinician time to read alert messages, time to warfarin therapy modification, and monitoring frequency. No significant differences were detected in major hemorrhage and thromboembolism, warfarin prescribing patterns, PT/INR results, warfarin therapy modification, or monitoring frequency following implementation of the PHS text alert system. In both study periods, approximately 80% of critical results led to warfarin discontinuation or dose reduction. Senior physicians' follow-up response time to critical results was significantly decreased in the PHS alert study period (46.3% responded within 1 day) compared to the manual notification study period (24.7%; P = 0.015). No difference in follow-up response time
Rymer, C.; Williams, B.A.; Brooks, A.E.; Davies, D.R.; Givens, D.I.
2005-01-01
A study was conducted to estimate variation among laboratories and between manual and automated techniques of measuring pressure on the resulting gas production profiles (GPP). Eight feeds (molassed sugarbeet feed, grass silage, maize silage, soyabean hulls, maize gluten feed, whole crop wheat
Erel, Ozcan
2004-04-01
To develop a novel colorimetric and automated direct measurement method for total antioxidant capacity (TAC). A new generation, more stable, colored 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid radical cation (ABTS(*+)) was employed. The ABTS(*+) is decolorized by antioxidants according to their concentrations and antioxidant capacities. This change in color is measured as a change in absorbance at 660 nm. This process is applied to an automated analyzer and the assay is calibrated with Trolox. The novel assay is linear up to 6 mmol Trolox equivalent/l, its precision values are lower than 3%, and there is no interference from hemoglobin, bilirubin, EDTA, or citrate. The method developed is significantly correlated with the Randox- total antioxidant status (TAS) assay (r = 0.897, P total antioxidant capacity.
Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan
2005-01-01
Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalco...
Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe
2018-01-04
The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.
Punjabi, Naresh M; Shifa, Naima; Dorffner, Georg; Patil, Susheel; Pien, Grace; Aurora, Rashmi N
2015-10-01
Manual scoring of polysomnograms is a time-consuming and tedious process. To expedite the scoring of polysomnograms, several computerized algorithms for automated scoring have been developed. The overarching goal of this study was to determine the validity of the Somnolyzer system, an automated system for scoring polysomnograms. The analysis sample comprised of 97 sleep studies. Each polysomnogram was manually scored by certified technologists from four sleep laboratories and concurrently subjected to automated scoring by the Somnolyzer system. Agreement between manual and automated scoring was examined. Sleep staging and scoring of disordered breathing events was conducted using the 2007 American Academy of Sleep Medicine criteria. Clinical sleep laboratories. A high degree of agreement was noted between manual and automated scoring of the apnea-hypopnea index (AHI). The average correlation between the manually scored AHI across the four clinical sites was 0.92 (95% confidence interval: 0.90-0.93). Similarly, the average correlation between the manual and Somnolyzer-scored AHI values was 0.93 (95% confidence interval: 0.91-0.96). Thus, interscorer correlation between the manually scored results was no different than that derived from manual and automated scoring. Substantial concordance in the arousal index, total sleep time, and sleep efficiency between manual and automated scoring was also observed. In contrast, differences were noted between manually and automated scored percentages of sleep stages N1, N2, and N3. Automated analysis of polysomnograms using the Somnolyzer system provides results that are comparable to manual scoring for commonly used metrics in sleep medicine. Although differences exist between manual versus automated scoring for specific sleep stages, the level of agreement between manual and automated scoring is not significantly different than that between any two human scorers. In light of the burden associated with manual scoring, automated
Directory of Open Access Journals (Sweden)
Fernanda C Dórea
Full Text Available BACKGROUND: Recent focus on earlier detection of pathogen introduction in human and animal populations has led to the development of surveillance systems based on automated monitoring of health data. Real- or near real-time monitoring of pre-diagnostic data requires automated classification of records into syndromes--syndromic surveillance--using algorithms that incorporate medical knowledge in a reliable and efficient way, while remaining comprehensible to end users. METHODS: This paper describes the application of two of machine learning (Naïve Bayes and Decision Trees and rule-based methods to extract syndromic information from laboratory test requests submitted to a veterinary diagnostic laboratory. RESULTS: High performance (F1-macro = 0.9995 was achieved through the use of a rule-based syndrome classifier, based on rule induction followed by manual modification during the construction phase, which also resulted in clear interpretability of the resulting classification process. An unmodified rule induction algorithm achieved an F(1-micro score of 0.979 though this fell to 0.677 when performance for individual classes was averaged in an unweighted manner (F(1-macro, due to the fact that the algorithm failed to learn 3 of the 16 classes from the training set. Decision Trees showed equal interpretability to the rule-based approaches, but achieved an F(1-micro score of 0.923 (falling to 0.311 when classes are given equal weight. A Naïve Bayes classifier learned all classes and achieved high performance (F(1-micro= 0.994 and F(1-macro = .955, however the classification process is not transparent to the domain experts. CONCLUSION: The use of a manually customised rule set allowed for the development of a system for classification of laboratory tests into syndromic groups with very high performance, and high interpretability by the domain experts. Further research is required to develop internal validation rules in order to establish
Révész, Kinga M.; Doctor, Daniel H.
2014-01-01
The purposes of the Reston Stable Isotope Laboratory (RSIL) lab codes 1851 and 1852 are to determine the total carbon mass and the ratio of the stable isotopes of carbon (δ13C) for total dissolved inorganic carbon (DIC, lab code 1851) and total nonpurgeable dissolved organic carbon (DOC, lab code 1852) in aqueous samples. The analysis procedure is automated according to a method that utilizes a total carbon analyzer as a peripheral sample preparation device for analysis of carbon dioxide (CO2) gas by a continuous-flow isotope ratio mass spectrometer (CF-IRMS). The carbon analyzer produces CO2 and determines the carbon mass in parts per million (ppm) of DIC and DOC in each sample separately, and the CF-IRMS determines the carbon isotope ratio of the produced CO2. This configuration provides a fully automated analysis of total carbon mass and δ13C with no operator intervention, additional sample preparation, or other manual analysis. To determine the DIC, the carbon analyzer transfers a specified sample volume to a heated (70 °C) reaction vessel with a preprogrammed volume of 10% phosphoric acid (H3PO4), which allows the carbonate and bicarbonate species in the sample to dissociate to CO2. The CO2 from the reacted sample is subsequently purged with a flow of helium gas that sweeps the CO2 through an infrared CO2 detector and quantifies the CO2. The CO2 is then carried through a high-temperature (650 °C) scrubber reactor, a series of water traps, and ultimately to the inlet of the mass spectrometer. For the analysis of total dissolved organic carbon, the carbon analyzer performs a second step on the sample in the heated reaction vessel during which a preprogrammed volume of sodium persulfate (Na2S2O8) is added, and the hydroxyl radicals oxidize the organics to CO2. Samples containing 2 ppm to 30,000 ppm of carbon are analyzed. The precision of the carbon isotope analysis is within 0.3 per mill for DIC, and within 0.5 per mill for DOC.
Robotics and Automation Education: Developing the Versatile, Practical Lab.
Stenerson, Jon
1986-01-01
Elements of the development of a robotics and automation laboratory are discussed. These include the benefits of upgrading current staff, ways to achieve this staff development, formation of a robotics factory automation committee, topics to be taught with a robot, elements of a laboratory, laboratory funding, and design safety. (CT)
Technology demonstration of space intravehicular automation and robotics
Morris, A. Terry; Barker, L. Keith
1994-01-01
Automation and robotic technologies are being developed and capabilities demonstrated which would increase the productivity of microgravity science and materials processing in the space station laboratory module, especially when the crew is not present. The Automation Technology Branch at NASA Langley has been working in the area of intravehicular automation and robotics (IVAR) to provide a user-friendly development facility, to determine customer requirements for automated laboratory systems, and to improve the quality and efficiency of commercial production and scientific experimentation in space. This paper will describe the IVAR facility and present the results of a demonstration using a simulated protein crystal growth experiment inside a full-scale mockup of the space station laboratory module using a unique seven-degree-of-freedom robot.
Improved compliance by BPM-driven workflow automation.
Holzmüller-Laue, Silke; Göde, Bernd; Fleischer, Heidi; Thurow, Kerstin
2014-12-01
Using methods and technologies of business process management (BPM) for the laboratory automation has important benefits (i.e., the agility of high-level automation processes, rapid interdisciplinary prototyping and implementation of laboratory tasks and procedures, and efficient real-time process documentation). A principal goal of the model-driven development is the improved transparency of processes and the alignment of process diagrams and technical code. First experiences of using the business process model and notation (BPMN) show that easy-to-read graphical process models can achieve and provide standardization of laboratory workflows. The model-based development allows one to change processes quickly and an easy adaption to changing requirements. The process models are able to host work procedures and their scheduling in compliance with predefined guidelines and policies. Finally, the process-controlled documentation of complex workflow results addresses modern laboratory needs of quality assurance. BPMN 2.0 as an automation language to control every kind of activity or subprocess is directed to complete workflows in end-to-end relationships. BPMN is applicable as a system-independent and cross-disciplinary graphical language to document all methods in laboratories (i.e., screening procedures or analytical processes). That means, with the BPM standard, a communication method of sharing process knowledge of laboratories is also available. © 2014 Society for Laboratory Automation and Screening.
Energy Technology Data Exchange (ETDEWEB)
McLean, Christopher T. [Univ. of New Mexico, Albuquerque, NM (United States)
2000-07-01
Los Alamos National Laboratory has a long-standing program of sampling storm water runoff inside the Laboratory boundaries. In 1995, the Laboratory started collecting the samples using automated storm water sampling stations; prior to this time the samples were collected manually. The Laboratory has also been periodically collecting sediment samples from Cochiti Lake. This paper presents the data for Pu-238 and Pu-239 bound to the sediments for Los Alamos Canyon storm water runoff and compares the sampling types by mass loading and as a percentage of the sediment deposition to Cochiti Lake. The data for both manual and automated sampling are used to calculate mass loads from Los Alamos Canyon on a yearly basis. The automated samples show mass loading 200- 500 percent greater for Pu-238 and 300-700 percent greater for Pu-239 than the manual samples. Using the mean manual flow volume for mass loading calculations, the automated samples are over 900 percent greater for Pu-238 and over 1800 percent greater for Pu-239. Evaluating the Pu-238 and Pu-239 activities as a percentage of deposition to Cochiti Lake indicates that the automated samples are 700-1300 percent greater for Pu- 238 and 200-500 percent greater for Pu-239. The variance was calculated by two methods. The first method calculates the variance for each sample event. The second method calculates the variances by the total volume of water discharged in Los Alamos Canyon for the year.
Costs of examinations performed in a hospital laboratory in Chile.
Andrade, Germán Lobos; Palma, Carolina Salas
2018-01-01
To determine the total average costs related to laboratory examinations performed in a hospital laboratory in Chile. Retrospective study with data from July 2014 to June 2015. 92 examinations classified in ten groups were selected according to the analysis methodology. The costs were estimated as the sum of direct and indirect laboratory costs and indirect institutional factors. The average values obtained for the costs according to examination group (in USD) were: 1.79 (clinical chemistry), 10.21 (immunoassay techniques), 13.27 (coagulation), 26.06 (high-performance liquid chromatography), 21.2 (immunological), 3.85 (gases and electrolytes), 156.48 (cytogenetic), 1.38 (urine), 4.02 (automated hematological), 4.93 (manual hematological). The value, or service fee, returned to public institutions who perform laboratory services does not adequately reflect the true total average production costs of examinations.
A sensor-based automation system for handling nuclear materials
International Nuclear Information System (INIS)
Drotning, W.; Kimberly, H.; Wapman, W.; Darras, D.
1997-01-01
An automated system is being developed for handling large payloads of radioactive nuclear materials in an analytical laboratory. The automation system performs unpacking and repacking of payloads from shipping and storage containers, and delivery of the payloads to the stations in the laboratory. The system uses machine vision and force/torque sensing to provide sensor-based control of the automation system in order to enhance system safety, flexibility, and robustness, and achieve easy remote operation. The automation system also controls the operation of the laboratory measurement systems and the coordination of them with the robotic system. Particular attention has been given to system design features and analytical methods that provide an enhanced level of operational safety. Independent mechanical gripper interlock and tool release mechanisms were designed to prevent payload mishandling. An extensive Failure Modes and Effects Analysis of the automation system was developed as a safety design analysis tool
Microcontrollers in the Laboratory.
Williams, Ron
1989-01-01
Described is the use of automated control using microcomputers. Covers the development of the microcontroller and describes advantages and characteristics of several brands of chips. Provides several recent applications of microcontrollers in laboratory automation. (MVL)
Biomek Cell Workstation: A Variable System for Automated Cell Cultivation.
Lehmann, R; Severitt, J C; Roddelkopf, T; Junginger, S; Thurow, K
2016-06-01
Automated cell cultivation is an important tool for simplifying routine laboratory work. Automated methods are independent of skill levels and daily constitution of laboratory staff in combination with a constant quality and performance of the methods. The Biomek Cell Workstation was configured as a flexible and compatible system. The modified Biomek Cell Workstation enables the cultivation of adherent and suspension cells. Until now, no commercially available systems enabled the automated handling of both types of cells in one system. In particular, the automated cultivation of suspension cells in this form has not been published. The cell counts and viabilities were nonsignificantly decreased for cells cultivated in AutoFlasks in automated handling. The proliferation of manual and automated bioscreening by the WST-1 assay showed a nonsignificant lower proliferation of automatically disseminated cells associated with a mostly lower standard error. The disseminated suspension cell lines showed different pronounced proliferations in descending order, starting with Jurkat cells followed by SEM, Molt4, and RS4 cells having the lowest proliferation. In this respect, we successfully disseminated and screened suspension cells in an automated way. The automated cultivation and dissemination of a variety of suspension cells can replace the manual method. © 2015 Society for Laboratory Automation and Screening.
DEFF Research Database (Denmark)
Stangegaard, Michael; Olsen, Addie Nina; Frøslev, Tobias G.
2009-01-01
We have implemented and validated automated methods for washing FTA Card punches containing buccal samples and subsequent PCR setup using a Sias Xantus automated liquid handler. The automated methods were controlled by worklists generated by our LabWare Laboratory Information Management System...
Blick, Kenneth E
2013-08-01
To develop a fully automated core laboratory, handling samples on a "first in, first out" real-time basis with Lean/Six Sigma management tools. Our primary goal was to provide services to critical care areas, eliminating turnaround time outlier percentage (TAT-OP) as a factor in patient length of stay (LOS). A secondary goal was to achieve a better laboratory return on investment. In 2011, we reached our primary goal when we calculated the TAT-OP distribution and found we had achieved a Six Sigma level of performance, ensuring that our laboratory service can be essentially eliminated as a factor in emergency department patient LOS. We also measured return on investment, showing a productivity improvement of 35%, keeping pace with our increased testing volume. As a result of our Lean process improvements and Six Sigma initiatives, in part through (1) strategic deployment of point-of-care testing and (2) core laboratory total automation with robotics, middleware, and expert system technology, physicians and nurses at the Oklahoma University Medical Center can more effectively deliver lifesaving health care using evidence-based protocols that depend heavily on "on time, every time" laboratory services.
International Nuclear Information System (INIS)
Thompson, K.A.; Walker, L.R.
1986-01-01
The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area
McLagan, David S.; Huang, Haiyong; Lei, Ying D.; Wania, Frank; Mitchell, Carl P. J.
2017-07-01
Analysis of high sulphur-containing samples for total mercury content using automated thermal decomposition, amalgamation, and atomic absorption spectroscopy instruments (USEPA Method 7473) leads to rapid and costly SO2 poisoning of catalysts. In an effort to overcome this issue, we tested whether the addition of powdered sodium carbonate (Na2CO3) to the catalyst and/or directly on top of sample material increases throughput of sulphur-impregnated (8-15 wt%) activated carbon samples per catalyst tube. Adding 5 g of Na2CO3 to the catalyst alone only marginally increases the functional lifetime of the catalyst (31 ± 4 g of activated carbon analyzed per catalyst tube) in relation to unaltered catalyst of the AMA254 total mercury analyzer (17 ± 4 g of activated carbon). Adding ≈ 0.2 g of Na2CO3 to samples substantially increases (81 ± 17 g of activated carbon) catalyst life over the unaltered catalyst. The greatest improvement is achieved by adding Na2CO3 to both catalyst and samples (200 ± 70 g of activated carbon), which significantly increases catalyst performance over all other treatments and enables an order of magnitude greater sample throughput than the unaltered samples and catalyst. It is likely that Na2CO3 efficiently sequesters SO2, even at high furnace temperatures to produce Na2SO4 and CO2, largely negating the poisonous impact of SO2 on the catalyst material. Increased corrosion of nickel sampling boats resulting from this methodological variation is easily resolved by substituting quartz boats. Overall, this variation enables an efficient and significantly more affordable means of employing automated atomic absorption spectrometry instruments for total mercury analysis of high-sulphur matrices.
International Nuclear Information System (INIS)
Watzlawik, K.H.
1979-12-01
A real-time data acquisition and processing system for the analytical laboratory of an experimental HTR spent fuel reprocessing facility is presented. The on-line open-loop system combines in-line and off-line analytical measurement procedures including data acquisition and evaluation as well as analytical laboratory organisation under the control of a computer-supported laboratory automation system. In-line measurements are performed for density, volume and temperature in process tanks and registration of samples for off-line measurements. Off-line computer-coupled experiments are potentiometric titration, gas chromatography and X-ray fluorescence analysis. Organisational sections like sample registration, magazining, distribution and identification, multiple data assignment and especially calibrations of analytical devices are performed by the data processing system. (orig.) [de
International Nuclear Information System (INIS)
Cristiano, Barbara F.G.; Delgado, Jose U.; Araujo, Radier M.S. de; Silva, Jose W.S. da; Barros, Pedro D. de
2009-01-01
Brazilian nuclear facilities, in accordance with the regulation CNEN-NN-2.02, must have available measurement systems which allow to determine their nuclear material inventories. For the evaluation and the follow up the performance of the involved laboratories in those measurement systems, the accomplishment of interlaboratory comparison programmes becomes fundamental. Therefore, the implementation of the potentiometric titration viewing the characterization of uranium samples, represents an reference element for the Brazilian programs
An overview of the contaminant analysis automation program
International Nuclear Information System (INIS)
Hollen, R.M.; Erkkila, T.; Beugelsdijk, T.J.
1992-01-01
The Department of Energy (DOE) has significant amounts of radioactive and hazardous wastes stored, buried, and still being generated at many sites within the United States. These wastes must be characterized to determine the elemental, isotopic, and compound content before remediation can begin. In this paper, the authors project that sampling requirements will necessitate generating more than 10 million samples by 1995, which will far exceed the capabilities of our current manual chemical analysis laboratories. The Contaminant Analysis Automation effort (CAA), with Los Alamos National Laboratory (LANL) as to the coordinating Laboratory, is designing and fabricating robotic systems that will standardize and automate both the hardware and the software of the most common environmental chemical methods. This will be accomplished by designing and producing several unique analysis systems called Standard Analysis Methods (SAM). Each SAM will automate a specific chemical method, including sample preparation, the analytical analysis, and the data interpretation, by using a building block known as the Standard Laboratory Module (SLM). This concept allows the chemist to assemble an automated environmental method using standardized SLMs easily and without the worry of hardware compatibility or the necessity of generating complicated control programs
Automated controlled-potential coulometric determination of uranium
International Nuclear Information System (INIS)
Knight, C.H.; Clegg, D.E.; Wright, K.D.; Cassidy, R.M.
1982-06-01
A controlled-potential coulometer has been automated in our laboratory for routine determination of uranium in solution. The CRNL-designed automated system controls degassing, prereduction, and reduction of the sample. The final result is displayed on a digital coulometer readout. Manual and automated modes of operation are compared to show the precision and accuracy of the automated system. Results are also shown for the coulometric titration of typical uranium-aluminum alloy samples
A fully automated mass spectrometer for the analysis of organic solids
International Nuclear Information System (INIS)
Hillig, H.; Kueper, H.; Riepe, W.
1979-01-01
Automation of a mass spectrometer-computer system makes it possible to process up to 30 samples without attention after sample loading. An automatic sample changer introduces the samples successively into the ion source by means of a direct inlet probe. A process control unit determines the operation sequence. Computer programs are available for the hardware support, system supervision and evaluation of the spectrometer signals. The most essential precondition for automation - automatic evaporation of the sample material by electronic control of the total ion current - is confirmed to be satisfactory. The system operates routinely overnight in an industrial laboratory, so that day work can be devoted to difficult analytical problems. The cost of routine analyses is halved. (Auth.)
Energy Technology Data Exchange (ETDEWEB)
Lifton, Nathaniel, E-mail: nlifton@purdue.edu [Department of Earth, Atmospheric, and Planetary Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907 (United States); Department of Physics and Astronomy and Purdue Rare Isotope Measurement Laboratory (PRIME Lab), Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States); Goehring, Brent, E-mail: bgoehrin@tulane.edu [Department of Earth, Atmospheric, and Planetary Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907 (United States); Wilson, Jim, E-mail: jim.wilson@aeonlaboratories.com [Aeon Laboratories, LLC, 5835 North Genematas Drive, Tucson, AZ 85704 (United States); Kubley, Thomas [Department of Physics and Astronomy and Purdue Rare Isotope Measurement Laboratory (PRIME Lab), Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States); Caffee, Marc [Department of Earth, Atmospheric, and Planetary Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, IN 47907 (United States); Department of Physics and Astronomy and Purdue Rare Isotope Measurement Laboratory (PRIME Lab), Purdue University, 525 Northwestern Avenue, West Lafayette, IN 47907 (United States)
2015-10-15
Current extraction methods for in situ {sup 14}C from quartz [e.g., Lifton et al., (2001), Pigati et al., (2010), Hippe et al., (2013)] are time-consuming and repetitive, making them an attractive target for automation. We report on the status of in situ {sup 14}C extraction and purification systems originally automated at the University of Arizona that have now been reconstructed and upgraded at the Purdue Rare Isotope Measurement Laboratory (PRIME Lab). The Purdue in situ {sup 14}C laboratory builds on the flow-through extraction system design of Pigati et al. (2010), automating most of the procedure by retrofitting existing valves with external servo-controlled actuators, regulating the pressure of research purity O{sub 2} inside the furnace tube via a PID-based pressure controller in concert with an inlet mass flow controller, and installing an automated liquid N{sub 2} distribution system, all driven by LabView® software. A separate system for cryogenic CO{sub 2} purification, dilution, and splitting is also fully automated, ensuring a highly repeatable process regardless of the operator. We present results from procedural blanks and an intercomparison material (CRONUS-A), as well as results of experiments to increase the amount of material used in extraction, from the standard 5 g to 10 g or above. Results thus far are quite promising with procedural blanks comparable to previous work and significant improvements in reproducibility for CRONUS-A measurements. The latter analyses also demonstrate the feasibility of quantitative extraction of in situ {sup 14}C from sample masses up to 10 g. Our lab is now analyzing unknowns routinely, but lowering overall blank levels is the focus of ongoing research.
International Nuclear Information System (INIS)
Regulla, D.F.; Drexeler, G.
Although the film seems to continue serving as the main personnel dosemeter in Germany for the time in sight, the evolution of particularly solid state techniques and their properties are thoroughly considered with respect to a possible generalized application in personnel monitoring. For this reason different automated TLD systems that are commercially available have been investigated in the laboratory in order to find out their usefulness for a largescale or also decentralized service. Along with studying the dosimetrical and apparative parameters, the question has been discussed to which monitoring philosophy these TLD systems seem to fit. It is reported both on experimental experiences achieved as well as on the results of basic discussions that in return influence the discussion about the necessary outfit of personnel TL dosemeters
Oneill-Rood, Nora; Glover, Richard D.
1990-01-01
NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.
Gazes, Regina Paxton; Brown, Emily Kathryn; Basile, Benjamin M; Hampton, Robert R
2013-05-01
Cognitive abilities likely evolved in response to specific environmental and social challenges and are therefore expected to be specialized for the life history of each species. Specialized cognitive abilities may be most readily engaged under conditions that approximate the natural environment of the species being studied. While naturalistic environments might therefore have advantages over laboratory settings for cognitive research, it is difficult to conduct certain types of cognitive tests in these settings. We implemented methods for automated cognitive testing of monkeys (Macaca mulatta) in large social groups (Field station) and compared the performance to that of laboratory-housed monkeys (Laboratory). The Field station animals shared access to four touch-screen computers in a large naturalistic social group. Each Field station subject had an RFID chip implanted in each arm for computerized identification and individualized assignment of cognitive tests. The Laboratory group was housed and tested in a typical laboratory setting, with individual access to testing computers in their home cages. Monkeys in both groups voluntarily participated at their own pace for food rewards. We evaluated performance in two visual psychophysics tests, a perceptual classification test, a transitive inference test, and a delayed matching-to-sample memory test. Despite the differences in housing, social environment, age, and sex, monkeys in the two groups performed similarly in all tests. Semi-free ranging monkeys living in complex social environments are therefore viable subjects for cognitive testing designed to take advantage of the unique affordances of naturalistic testing environments.
Automation, consolidation, and integration in autoimmune diagnostics.
Tozzoli, Renato; D'Aurizio, Federica; Villalta, Danilo; Bizzaro, Nicola
2015-08-01
Over the past two decades, we have witnessed an extraordinary change in autoimmune diagnostics, characterized by the progressive evolution of analytical technologies, the availability of new tests, and the explosive growth of molecular biology and proteomics. Aside from these huge improvements, organizational changes have also occurred which brought about a more modern vision of the autoimmune laboratory. The introduction of automation (for harmonization of testing, reduction of human error, reduction of handling steps, increase of productivity, decrease of turnaround time, improvement of safety), consolidation (combining different analytical technologies or strategies on one instrument or on one group of connected instruments) and integration (linking analytical instruments or group of instruments with pre- and post-analytical devices) opened a new era in immunodiagnostics. In this article, we review the most important changes that have occurred in autoimmune diagnostics and present some models related to the introduction of automation in the autoimmunology laboratory, such as automated indirect immunofluorescence and changes in the two-step strategy for detection of autoantibodies; automated monoplex immunoassays and reduction of turnaround time; and automated multiplex immunoassays for autoantibody profiling.
Automated Information System (AIS) Alarm System
International Nuclear Information System (INIS)
Hunteman, W.
1997-01-01
The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies
Automated Information System (AIS) Alarm System
Energy Technology Data Exchange (ETDEWEB)
Hunteman, W.
1997-05-01
The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.
Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.
Chen, Liming; Chen, Yu
2015-01-01
Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.
Supervisory Control and Data Acquisition Laboratory
Directory of Open Access Journals (Sweden)
M. Iacob
2010-06-01
Full Text Available This paper presents practical laboratories for teaching purpose in Supervisory Control and Data Acquisition (SCADA systems. A SCADA system is described in terms of architecture, process interfaces, functionality, and application development facilities. These concepts are implemented on an integrated automation system, particularly for digital control of electric drives with a distributed peripheral, i.e., Totally Integrated Automation with Democase from Siemens. Using this system, a wide range of applications can be designed, implemented and tested. A practical labs set is presented to introduce gradually the main SCADA elements, and finally to develop an application to control an induction motor in interlocked manual/automatic mode, with touch-screen Human Machine Interface (HMI. The system employs industrial busses like PROFIBus and industrial Ethernet. The SCADA system also shows trends, alarms, motor frequency and automatic sequence of motor speed profile.
Flexible End2End Workflow Automation of Hit-Discovery Research.
Holzmüller-Laue, Silke; Göde, Bernd; Thurow, Kerstin
2014-08-01
The article considers a new approach of more complex laboratory automation at the workflow layer. The authors purpose the automation of end2end workflows. The combination of all relevant subprocesses-whether automated or manually performed, independently, and in which organizational unit-results in end2end processes that include all result dependencies. The end2end approach focuses on not only the classical experiments in synthesis or screening, but also on auxiliary processes such as the production and storage of chemicals, cell culturing, and maintenance as well as preparatory activities and analyses of experiments. Furthermore, the connection of control flow and data flow in the same process model leads to reducing of effort of the data transfer between the involved systems, including the necessary data transformations. This end2end laboratory automation can be realized effectively with the modern methods of business process management (BPM). This approach is based on a new standardization of the process-modeling notation Business Process Model and Notation 2.0. In drug discovery, several scientific disciplines act together with manifold modern methods, technologies, and a wide range of automated instruments for the discovery and design of target-based drugs. The article discusses the novel BPM-based automation concept with an implemented example of a high-throughput screening of previously synthesized compound libraries. © 2014 Society for Laboratory Automation and Screening.
Hadimioglu, Babur; Stearns, Richard; Ellson, Richard
2016-02-01
Liquid handling instruments for life science applications based on droplet formation with focused acoustic energy or acoustic droplet ejection (ADE) were introduced commercially more than a decade ago. While the idea of "moving liquids with sound" was known in the 20th century, the development of precise methods for acoustic dispensing to aliquot life science materials in the laboratory began in earnest in the 21st century with the adaptation of the controlled "drop on demand" acoustic transfer of droplets from high-density microplates for high-throughput screening (HTS) applications. Robust ADE implementations for life science applications achieve excellent accuracy and precision by using acoustics first to sense the liquid characteristics relevant for its transfer, and then to actuate transfer of the liquid with customized application of sound energy to the given well and well fluid in the microplate. This article provides an overview of the physics behind ADE and its central role in both acoustical and rheological aspects of robust implementation of ADE in the life science laboratory and its broad range of ejectable materials. © 2015 Society for Laboratory Automation and Screening.
Directory of Open Access Journals (Sweden)
Ebru Kale
2006-04-01
CONCLUSIONS: Our findings suggest that preeclampsia is related with enhanced lipid peroxidation and decreased total antioxidant response before delivery and these parameters may be related at least partly to the pathogenesis of preeclampsia. Decreased lipid peroxidation and increased total antioxidant response after delivery may suggest recov ery of preeclampsia and using a simple, rapid and reliable automated method f acilitates to ev aluate and follow up of the lev els of oxidativ e stress in preeclampsia and this novel method may be used as a routine test in clinical practice while managing preeclampsia
Mayer, Horst; Brümmer, Jens; Brinkmann, Thomas
2011-01-01
To implement Lean Six Sigma in our central laboratory we conducted a project to measure single pre-analytical steps influencing turnaround time (TAT) of emergency department (ED) serum samples. The traditional approach of extracting data from the Laboratory Information System (LIS) for a retrospective calculation of a mean TAT is not suitable. Therefore, we used radiofrequency identification (RFID) chips for real time tracking of individual samples at any pre-analytical step. 1,200 serum tubes were labelled with RFID chips and were provided to the emergency department. 3 RFID receivers were installed in the laboratory: at the outlet of the pneumatic tube system, at the centrifuge, and in the analyser area. In addition, time stamps of sample entry at the automated sample distributor and communication of results from the analyser were collected from LIS. 1,023 labelled serum tubes arrived at our laboratory. 899 RFID tags were used for TAT calculation. The following transfer times were determined (median 95th percentile in min:sec): pneumatic tube system --> centrifuge (01:25/04:48), centrifuge --> sample distributor (14:06/5:33), sample distributor --> analysis system zone (02:39/15:07), analysis system zone --> result communication (12:42/22:21). Total TAT was calculated at 33:19/57:40 min:sec. Manual processes around centrifugation were identified as a major part of TAT with 44%/60% (median/95th percentile). RFID is a robust, easy to use, and error-free technology and not susceptible to interferences in the laboratory environment. With this study design we were able to measure significant variations in a single manual sample transfer process. We showed that TAT is mainly influenced by manual steps around the centrifugation process and we concluded that centrifugation should be integrated in solutions for total laboratory automation.
Potter, Brian J; Matteau, Alexis; Mansour, Samer; Naim, Charbel; Riahi, Mounir; Essiambre, Richard; Montigny, Martine; Sareault, Isabelle; Gobeil, François
2017-01-01
Treatment times for primary percutaneous coronary intervention frequently exceed the recommended maximum delay. Automated "physicianless" systems of prehospital cardiac catheterization laboratory (CCL) activation show promise, but have been met with resistance over concerns regarding the potential for false positive and inappropriate activations (IAs). From 2010 to 2015, first responders performed electrocardiograms (ECGs) in the field for all patients with a complaint of chest pain or dyspnea. An automated machine diagnosis of "acute myocardial infarction" resulted in immediate CCL activation and direct transfer without transmission or human reinterpretation of the ECG prior to patient arrival. Any activation resulting from a nondiagnostic ECG (no ST-elevation) was deemed an IA, whereas activations resulting from ECG's compatible with ST-elevation myocardial infarction but without angiographic evidence of a coronary event were deemed false positive. In 2012, the referral algorithm was modified to exclude supraventricular tachycardia and left bundle branch block. There were 155 activations in the early cohort (2010-2012; prior to algorithm modification) and 313 in the late cohort (2012-2015). Algorithm modification resulted in a 42% relative decrease in the rate of IAs (12% vs 7%; P IA and false positive is at least on par with systems that ensure real-time human oversight. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Automation of MCDOR at NMT-3 Los Alamos National Laboratory. Final report
International Nuclear Information System (INIS)
Shahinpoor, M.
1997-01-01
The automation of various parts of multiple--cycle direct oxide reduction (MCDOR) at LANL's NMT-3 was the goal of this research and development activities. In particular, originally the following goals were assigned to the author by the NMT-3 technical staff leaders (Greg Bird, Jim McNeese, Joel Williams): (1) Design and fabricate an automation set up; (2) Step-wise automation is preferred; (3) Step 1 involves automatic metering and mixing of powders; and (4) Step 2-automatic transport of powder to furnace location The initial task assigned in May 91 was to get the appropriate design developed and order equipment and parts to automatically weight powders. In fact the work statement read open-quotes Create an experimental automation set up in the ME Department at UNM to automatically weigh powders using an electronic balance. Further, design the set up such that the electronic balance is reprogrammable for specific weight set points. Thus, when a set point in weight is reached by means of a vibratory feeder feeding a container on the balance, the electronic balance will send an electronic signal out to switch off the vibratory feederclose quotes. The automation of the reduction of plutonium oxide to plutonium is described
Automation of MCDOR at NMT-3 Los Alamos National Laboratory. Final report
Energy Technology Data Exchange (ETDEWEB)
Shahinpoor, M.
1997-01-01
The automation of various parts of multiple--cycle direct oxide reduction (MCDOR) at LANL`s NMT-3 was the goal of this research and development activities. In particular, originally the following goals were assigned to the author by the NMT-3 technical staff leaders (Greg Bird, Jim McNeese, Joel Williams): (1) Design and fabricate an automation set up; (2) Step-wise automation is preferred; (3) Step 1 involves automatic metering and mixing of powders; and (4) Step 2-automatic transport of powder to furnace location The initial task assigned in May 91 was to get the appropriate design developed and order equipment and parts to automatically weight powders. In fact the work statement read {open_quotes}Create an experimental automation set up in the ME Department at UNM to automatically weigh powders using an electronic balance. Further, design the set up such that the electronic balance is reprogrammable for specific weight set points. Thus, when a set point in weight is reached by means of a vibratory feeder feeding a container on the balance, the electronic balance will send an electronic signal out to switch off the vibratory feeder{close_quotes}. The automation of the reduction of plutonium oxide to plutonium is described.
Automated activation-analysis system
International Nuclear Information System (INIS)
Minor, M.M.; Garcia, S.R.; Denton, M.M.
1982-01-01
An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day
International Nuclear Information System (INIS)
Hunt, M.A.; Klatt, L.N.; Thompson, D.H.
1998-02-01
The Chemical Analysis Automation (CAA) project is developing standardized, software-driven, site-deployable robotic laboratory systems with the objective of lowering the per-sample analysis cost, decreasing sample turnaround time, and minimizing human exposure to hazardous and radioactive materials associated with DOE remediation projects. The first integrated system developed by the CAA project is designed to determine polychlorinated biphenyls (PCB) content in soil matrices. A demonstration and development testing of this system was conducted in conjuction with surface soil characterization activities at the David Witherspoon 1630 Site in Knoxville, Tennessee. The PCB system consists of five hardware standard laboratory modules (SLMs), one software SLM, the task sequence controller (TSC), and the human-computer interface (HCI). Four of the hardware SLMs included a four-channel Soxhlet extractor, a high-volume concentrator, a column cleanup, and a gas chromatograph. These SLMs performed the sample preparation and measurement steps within the total analysis protocol. The fifth hardware module was a robot that transports samples between the SLMs and the required consumable supplies to the SLMs. The software SLM is an automated data interpretation module that receives raw data from the gas chromatograph SLM and analyzes the data to yield the analyte information. The TSC is a software system that provides the scheduling, management of system resources, and the coordination of all SLM activities. The HCI is a graphical user interface that presents the automated laboratory to the analyst in terms of the analytical procedures and methods. Human control of the automated laboratory is accomplished via the HCI. Sample information required for processing by the automated laboratory is entered through the HCI. Information related to the sample and the system status is presented to the analyst via graphical icons
BIOPLUS: An eclectic laboratory information management system for the ORNL Radiobioassay Laboratory
Energy Technology Data Exchange (ETDEWEB)
Ferguson, R.L.; Hwang, H.L.; Bishop, C.P.; Blair, R.L.; Cornett, R.L.; Gonzalez, B.D.; Hotchandani, M.; Keaton, J.A.; Miller, J.L.; Myers, R.D.; Ohnesorge, M.J.; Thein, M.
1992-12-31
Data management activities in analytical laboratories can include sample scheduling, logging, and tracking, as well as results collection and reporting. In the Radiobioassay Laboratory (RBL) such activities were formerly accomplished by entering data in log books and on forms followed by manual entry of data into a computer database. As sample load has increased and further emphasis has been placed on improving efficiency and on error reduction, it has become worthwhile to automate the laboratory`s information management. In addition, a Bioassay Data Management System (BDMS) has developed for use by all five of the DOE sites managed by Martin Marietta Energy Systems in order to centralize bioassay data management for internal dosimetry purposes. BIOPLUS, the LIMS described in this paper, provides an interface with BDMS and automates RBL information management to a large extent. The system provides for downloading personnel data from a central computer, logging in samples, and bar-code sample tracking, as well as recording, reporting, archiving, and trending of analysis results. Sketches of the hardware and software are presented along with some details of the instrument interface modules.
Automation on an Open-Access Platform of Alzheimer's Disease Biomarker Immunoassays.
Gille, Benjamin; Dedeene, Lieselot; Stoops, Erik; Demeyer, Leentje; Francois, Cindy; Lefever, Stefanie; De Schaepdryver, Maxim; Brix, Britta; Vandenberghe, Rik; Tournoy, Jos; Vanderstichele, Hugo; Poesen, Koen
2018-04-01
The lack of (inter-)laboratory standardization has hampered the application of universal cutoff values for Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers and their transfer to general clinical practice. The automation of the AD biomarker immunoassays is suggested to generate more robust results than using manual testing. Open-access platforms will facilitate the integration of automation for novel biomarkers, allowing the introduction of the protein profiling concept. A feasibility study was performed on an automated open-access platform of the commercial immunoassays for the 42-amino-acid isoform of amyloid-β (Aβ 1-42 ), Aβ 1-40 , and total tau in CSF. Automated Aβ 1-42 , Aβ 1-40 , and tau immunoassays were performed within predefined acceptance criteria for bias and imprecision. Similar accuracy was obtained for ready-to-use calibrators as for reconstituted lyophilized kit calibrators. When compared with the addition of a standard curve in each test run, the use of a master calibrator curve, determined before and applied to each batch analysis as the standard curve, yielded an acceptable overall bias of -2.6% and -0.9% for Aβ 1-42 and Aβ 1-40 , respectively, with an imprecision profile of 6.2% and 8.4%, respectively. Our findings show that transfer of commercial manual immunoassays to fully automated open-access platforms is feasible, as it performs according to universal acceptance criteria.
Mockup of an automated material transport system for remote handling
International Nuclear Information System (INIS)
Porter, M.L.
1992-01-01
An Automated Material Transport System (AMTS) was identified for transport of samples within a Material and Process Control Laboratory (MPCL). The MPCL was designed with a dry sample handling laboratory and a wet chemistry analysis laboratory. Each laboratory contained several processing gloveboxes. The function of the AMTS was to automate the handling of materials, multiple process samples, and bulky items between process stations with a minimum of operator intervention and with minimum o[ waiting periods and nonproductive activities. This paper discusses the system design features, capabilities and results of initial testing. The overall performance of the AMTS is very good. No major problems or concerns were identified. System commands are simple and logical making the system user friendly. Operating principle and design of individual components is simple. With the addition of various track modules, the system can be configured in most any configuration. The AMTS lends itself very well for integration with other automated systems or products. The AMTS is suited for applications involving light payloads which require multiple sample and material handling, lot tracking, and system integration with other products
An automation of physics research on base of open standards
International Nuclear Information System (INIS)
Smirnov, V.A.
1997-01-01
A wide range of problems is considered concerning an automation of Laboratory of High Energies, JINR set-ups oriented to carry out the experimental researches in high energy and relativistic nuclear physics. Electronics of discussed automation systems is performed in open standards. Main peculiarities in the creation process of automation tools for experimental set-ups, stands and accelerators are shown. Some possibilities to build some accelerator control subsystems on base of industrial automation methods and techniques are discussed
Emerging Technologies for the Clinical Microbiology Laboratory
Buchan, Blake W.
2014-01-01
SUMMARY In this review we examine the literature related to emerging technologies that will help to reshape the clinical microbiology laboratory. These topics include nucleic acid amplification tests such as isothermal and point-of-care molecular diagnostics, multiplexed panels for syndromic diagnosis, digital PCR, next-generation sequencing, and automation of molecular tests. We also review matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry methods and their role in identification of microorganisms. Lastly, we review the shift to liquid-based microbiology and the integration of partial and full laboratory automation that are beginning to impact the clinical microbiology laboratory. PMID:25278575
International Nuclear Information System (INIS)
Tway, P.C.; Love, L.J.C.; Woodruff, H.B.
1980-01-01
Target transformation factor analysis is applied to typical data from gas chromatography-mass spectrometry and solid-probe mass spectrometry to determine rapidly the number of components in unresolved or partially resolved peaks. This technique allows the detection of hidden impurities which often make interpretation or quantification impossible. The error theory of Malinowski is used to assess the reliability of the results. The totally automated system uses a commercially available g.c.-m.s. data system interfaced to the large computer, and the number of components under a peak can be determined routinely and rapidly. (Auth.)
Feasibility study for the computerized automation of the Annapolis Field Office of EPA region III
International Nuclear Information System (INIS)
Ames, H.S.; Barton, G.W. Jr.; Bystroff, R.I.; Crawford, R.W.; Kray, A.M.; Maples, M.D.
1976-08-01
This report describes a feasibility study for computerized automation of the Annapolis Field Office (AFO) of EPA's Region III. The AFO laboratory provides analytical support for a number of EPA divisions; its primary function at present is analysis of water samples from rivers, estuaries, and the ocean in the Chesapeake Bay area. Automation of the AFO laboratory is found to be not only feasible but also highly desirable. An automation system is proposed which will give major improvements in analytical capacity, quality control, sample management, and reporting capabilities. This system is similar to the LLL-developed automation systems already installed at other EPA laboratories, with modifications specific to the needs of the AFO laboratory and the addition of sample file control. It is estimated that the initial cost of the system, nearly $300,000, would be recouped in about three years by virtue of the increased capacity and efficiency of operation
Directory of Open Access Journals (Sweden)
Kara Brower
2018-04-01
Full Text Available Microfluidic technologies have been used across diverse disciplines (e.g. high-throughput biological measurement, fluid physics, laboratory fluid manipulation but widespread adoption has been limited in part due to the lack of openly disseminated resources that enable non-specialist labs to make and operate their own devices. Here, we report the open-source build of a pneumatic setup capable of operating both single and multilayer (Quake-style microfluidic devices with programmable scripting automation. This setup can operate both simple and complex devices with 48 device valve control inputs and 18 sample inputs, with modular design for easy expansion, at a fraction of the cost of similar commercial solutions. We present a detailed step-by-step guide to building the pneumatic instrumentation, as well as instructions for custom device operation using our software, Geppetto, through an easy-to-use GUI for live on-chip valve actuation and a scripting system for experiment automation. We show robust valve actuation with near real-time software feedback and demonstrate use of the setup for high-throughput biochemical measurements on-chip. This open-source setup will enable specialists and novices alike to run microfluidic devices easily in their own laboratories. Keywords: Microfluidics, Pneumatics, Laboratory automation, Biochip, BioMEMs, Biohacking, Fluid handling, Micro total analysis systems (μTAS, Quake-style valves
Roy, Somak; Durso, Mary Beth; Wald, Abigail; Nikiforov, Yuri E; Nikiforova, Marina N
2014-01-01
A wide repertoire of bioinformatics applications exist for next-generation sequencing data analysis; however, certain requirements of the clinical molecular laboratory limit their use: i) comprehensive report generation, ii) compatibility with existing laboratory information systems and computer operating system, iii) knowledgebase development, iv) quality management, and v) data security. SeqReporter is a web-based application developed using ASP.NET framework version 4.0. The client-side was designed using HTML5, CSS3, and Javascript. The server-side processing (VB.NET) relied on interaction with a customized SQL server 2008 R2 database. Overall, 104 cases (1062 variant calls) were analyzed by SeqReporter. Each variant call was classified into one of five report levels: i) known clinical significance, ii) uncertain clinical significance, iii) pending pathologists' review, iv) synonymous and deep intronic, and v) platform and panel-specific sequence errors. SeqReporter correctly annotated and classified 99.9% (859 of 860) of sequence variants, including 68.7% synonymous single-nucleotide variants, 28.3% nonsynonymous single-nucleotide variants, 1.7% insertions, and 1.3% deletions. One variant of potential clinical significance was re-classified after pathologist review. Laboratory information system-compatible clinical reports were generated automatically. SeqReporter also facilitated quality management activities. SeqReporter is an example of a customized and well-designed informatics solution to optimize and automate the downstream analysis of clinical next-generation sequencing data. We propose it as a model that may envisage the development of a comprehensive clinical informatics solution. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Sédille-Mostafaie, Nazanin; Engler, Hanna; Lutz, Susanne; Korte, Wolfgang
2013-06-01
Laboratories today face increasing pressure to automate operations due to increasing workloads and the need to reduce expenditure. Few studies to date have focussed on the laboratory automation of preanalytical coagulation specimen processing. In the present study, we examined whether a clinical chemistry automation protocol meets the preanalytical requirements for the analyses of coagulation. During the implementation of laboratory automation, we began to operate a pre- and postanalytical automation system. The preanalytical unit processes blood specimens for chemistry, immunology and coagulation by automated specimen processing. As the production of platelet-poor plasma is highly dependent on optimal centrifugation, we examined specimen handling under different centrifugation conditions in order to produce optimal platelet deficient plasma specimens. To this end, manually processed models centrifuged at 1500 g for 5 and 20 min were compared to an automated centrifugation model at 3000 g for 7 min. For analytical assays that are performed frequently enough to be targets for full automation, Passing-Bablok regression analysis showed close agreement between different centrifugation methods, with a correlation coefficient between 0.98 and 0.99 and a bias between -5% and +6%. For seldom performed assays that do not mandate full automation, the Passing-Bablok regression analysis showed acceptable to poor agreement between different centrifugation methods. A full automation solution is suitable and can be recommended for frequent haemostasis testing.
Automating Energy Bandgap Measurements in Semiconductors Using LabVIEW
Garg, Amit; Sharma, Reena; Dhingra, Vishal
2010-01-01
In this paper, we report the development of an automated system for energy bandgap and resistivity measurement of a semiconductor sample using Four-Probe method for use in the undergraduate laboratory of Physics and Electronics students. The automated data acquisition and analysis system has been developed using National Instruments USB-6008 DAQ…
Automation of unit for leakage test
LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.
2015-01-01
Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.
Guidelines for Automation Project Execution
Takkinen, Heidi
2011-01-01
The purpose of this Master’s thesis was to create instructions for executing an automation project. Sarlin Oy Ab needed directions on how to execute an automation project. Sarlin is starting up a new business area offering total project solutions for customers. Sarlin focuses on small and minor automation projects on domestic markets. The thesis represents issues related to project execution starting from the theory of the project to its kick-off and termination. Site work is one importan...
Automation for mineral resource development
Energy Technology Data Exchange (ETDEWEB)
Norrie, A.W.; Turner, D.R. (eds.)
1986-01-01
A total of 55 papers were presented at the symposium under the following headings: automation and the future of mining; modelling and control of mining processes; transportation for mining; automation and the future of metallurgical processes; modelling and control of metallurgical processes; and general aspects. Fifteen papers have been abstracted separately.
Manual versus automated blood sampling
DEFF Research Database (Denmark)
Teilmann, A C; Kalliokoski, Otto; Sørensen, Dorte B
2014-01-01
Facial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters......, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal...... corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups. Plasma corticosterone levels of mice subjected to tail blood sampling were also elevated, although less significantly. Mice subjected to automated blood sampling were less affected with regard to the parameters...
BIOPLUS: An eclectic laboratory information management system for the ORNL Radiobioassay Laboratory
Energy Technology Data Exchange (ETDEWEB)
Ferguson, R.L.; Hwang, H.L.; Bishop, C.P.; Blair, R.L.; Cornett, R.L.; Gonzalez, B.D.; Hotchandani, M.; Keaton, J.A.; Miller, J.L.; Myers, R.D.; Ohnesorge, M.J.; Thein, M.
1992-01-01
Data management activities in analytical laboratories can include sample scheduling, logging, and tracking, as well as results collection and reporting. In the Radiobioassay Laboratory (RBL) such activities were formerly accomplished by entering data in log books and on forms followed by manual entry of data into a computer database. As sample load has increased and further emphasis has been placed on improving efficiency and on error reduction, it has become worthwhile to automate the laboratory's information management. In addition, a Bioassay Data Management System (BDMS) has developed for use by all five of the DOE sites managed by Martin Marietta Energy Systems in order to centralize bioassay data management for internal dosimetry purposes. BIOPLUS, the LIMS described in this paper, provides an interface with BDMS and automates RBL information management to a large extent. The system provides for downloading personnel data from a central computer, logging in samples, and bar-code sample tracking, as well as recording, reporting, archiving, and trending of analysis results. Sketches of the hardware and software are presented along with some details of the instrument interface modules.
BIOPLUS: An eclectic laboratory information management system for the ORNL Radiobioassay Laboratory
International Nuclear Information System (INIS)
Ferguson, R.L.; Hwang, H.L.; Bishop, C.P.; Blair, R.L.; Cornett, R.L.; Gonzalez, B.D.; Hotchandani, M.; Keaton, J.A.; Miller, J.L.; Myers, R.D.; Ohnesorge, M.J.; Thein, M.
1992-01-01
Data management activities in analytical laboratories can include sample scheduling, logging, and tracking, as well as results collection and reporting. In the Radiobioassay Laboratory (RBL) such activities were formerly accomplished by entering data in log books and on forms followed by manual entry of data into a computer database. As sample load has increased and further emphasis has been placed on improving efficiency and on error reduction, it has become worthwhile to automate the laboratory's information management. In addition, a Bioassay Data Management System (BDMS) has developed for use by all five of the DOE sites managed by Martin Marietta Energy Systems in order to centralize bioassay data management for internal dosimetry purposes. BIOPLUS, the LIMS described in this paper, provides an interface with BDMS and automates RBL information management to a large extent. The system provides for downloading personnel data from a central computer, logging in samples, and bar-code sample tracking, as well as recording, reporting, archiving, and trending of analysis results. Sketches of the hardware and software are presented along with some details of the instrument interface modules
Fu, Qin; Kowalski, Michael P; Mastali, Mitra; Parker, Sarah J; Sobhani, Kimia; van den Broek, Irene; Hunter, Christie L; Van Eyk, Jennifer E
2018-01-05
Sample preparation for protein quantification by mass spectrometry requires multiple processing steps including denaturation, reduction, alkylation, protease digestion, and peptide cleanup. Scaling these procedures for the analysis of numerous complex biological samples can be tedious and time-consuming, as there are many liquid transfer steps and timed reactions where technical variations can be introduced and propagated. We established an automated sample preparation workflow with a total processing time for 96 samples of 5 h, including a 2 h incubation with trypsin. Peptide cleanup is accomplished by online diversion during the LC/MS/MS analysis. In a selected reaction monitoring (SRM) assay targeting 6 plasma biomarkers and spiked β-galactosidase, mean intraday and interday cyclic voltammograms (CVs) for 5 serum and 5 plasma samples over 5 days were samples repeated on 3 separate days had total CVs below 20%. Similar results were obtained when the workflow was transferred to a second site: 93% of peptides had CVs below 20%. An automated trypsin digestion workflow yields uniformly processed samples in less than 5 h. Reproducible quantification of peptides was observed across replicates, days, instruments, and laboratory sites, demonstrating the broad applicability of this approach.
A LabVIEW based template for user created experiment automation.
Kim, D J; Fisk, Z
2012-12-01
We have developed an expandable software template to automate user created experiments. The LabVIEW based template is easily modifiable to add together user created measurements, controls, and data logging with virtually any type of laboratory equipment. We use reentrant sequential selection to implement sequence script making it possible to wrap a long series of the user created experiments and execute them in sequence. Details of software structure and application examples for scanning probe microscope and automated transport experiments using custom built laboratory electronics and a cryostat are described.
Automated activation-analysis system
International Nuclear Information System (INIS)
Minor, M.M.; Hensley, W.K.; Denton, M.M.; Garcia, S.R.
1981-01-01
An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. The system and its mode of operation for a large reconnaissance survey are described
Laboratory Information Management System Chain of Custody: Reliability and Security
Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.
2006-01-01
A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare. PMID:17671623
Status of automated tensile machine
International Nuclear Information System (INIS)
Satou, M.; Hamilton, M.L.; Sato, S.; Kohyama, A.
1992-01-01
The objective of this work is to develop the Monbusho Automated Tensile machine (MATRON) and install and operate it at the Pacific Northwest Laboratory (PNL). The machine is designed to provide rapid, automated testing of irradiated miniature tensile specimen in a vacuum at elevated temperatures. The MATRON was successfully developed and shipped to PNL for installation in a hot facility. The original installation plan was modified to simplify the current and subsequent installations, and the installation was completed. Detailed procedures governing the operation of the system were written. Testing on irradiated miniature tensile specimen should begin in the near future
Repeatability and reproducibility of an automated gas production technique
Laar, van H.; Straalen, van W.M.; Gelder, van A.H.; Boever, de J.L.; heer, D' B.; Vedder, H.; Kroes, R.; Bot, de P.; Hees, van J.; Cone, J.W.
2006-01-01
Two ring tests with five and three laboratories, respectively, were conducted to quantify variation within and among laboratories in an automated gas production technique. Single batches of the feeds soya bean meal (SBM), wheat grain (WG), grass silage (GS) and maize gluten meal (MG) were divided
Laboratory equipment maintenance contracts.
Boudreau, D A; Scheer, W D; Catrou, P G
1985-12-01
The increasing level of technical sophistication and complexity found in clinical laboratory instrumentation today more than ever demands careful attention to maintenance service needs. The time-worn caution for careful definition of requirements for acquisition of a system should also carry over to acquisition of maintenance service. Guidelines are presented for specifications of terms and conditions for maintenance service from the perspective of the laboratorian in the automated clinical laboratory.
Shared robotic system: automated pipette calibration and pipette tip filter assembly
International Nuclear Information System (INIS)
Addison, J.H. Jr.; Dyches, G.M.
1985-01-01
At the Savannah River Laboratory a Zymate Laboratory Automation System has been developed to perform two completely independent tasks within one work cell. One operation is the precise calibration of pipettes; the other is the assembly of a filter in a pipette tip. Since neither task requires full robot time, the shared system is an economical means of robotizing both processes. These are tedious, repetitive, time consuming tasks; and human operators fail to yield constant results. Automation insures a repeatable process which increases product quality
Smith, Robert S.
1993-01-01
The result of a literature search to consider what technologies should be represented in a totally automated water quality monitor for extended space flight is presented. It is the result of the first summer in a three year JOVE project. The next step will be to build a test platform at the Authors' school, St. John Fisher College. This will involve undergraduates in NASA related research. The test flow injection analysis system will be used to test the detection limit of sensors and the performance of sensors in groups. Sensor companies and research groups will be encouraged to produce sensors which are not currently available and are needed for this project.
Hematology laboratory standardization: a plan for harmonization in Asia.
Bunyaratvej, A; Tatsumi, N; Funahara, Y
1999-01-01
Hematology laboratory is generally required in the hospital. At the macroscale, hematology laboratories have served a large number of population. In Asia, more than 3,000 million people are potentially to use the hematology laboratory service, particularly the complete blood count. Since 1970s, automated technology has been introduced to Asia and as years passed by, technology diversity is increasing. However, there are considerable number of hematology laboratories that have no automated machine. They are still relied on manual technology which is still variable in spectrophotometer for hemoglobin determination, centrifuge for hematocrit and diluting pipet for cell counting. In particular, blood smear preparation and interpretation are very difficult to control for standardization from person to person and laboratory to laboratory. Different methodology and a large population in the huge geographical area in Asia, the agreement of standard criteria is greatly important. This report has shown strategy and action plan to reach the goal of hematology laboratory standardization in Asia.
Automation Revolutionize the Business Service Industry
Marciniak, Róbert
2017-01-01
In the last decades significant disruptive changes began with the extended use of automation. Many jobs are changed or disappeared and others were born totally with the automation. Together with the progress of technology, the automation was primarily spread in the industrial sector, mostly in the production and assembly lines. The growth maycontinue in the future further, researchers expect more than 35 million industrial robots globally by 2018.But it shades the situati...
Ward, Dennis W.; Bennett, Kelly W.
2017-05-01
The Sensor Information Testbed COllaberative Research Environment (SITCORE) and the Automated Online Data Repository (AODR) are significant enablers of the U.S. Army Research Laboratory (ARL)'s Open Campus Initiative and together create a highly-collaborative research laboratory and testbed environment focused on sensor data and information fusion. SITCORE creates a virtual research development environment allowing collaboration from other locations, including DoD, industry, academia, and collation facilities. SITCORE combined with AODR provides end-toend algorithm development, experimentation, demonstration, and validation. The AODR enterprise allows the U.S. Army Research Laboratory (ARL), as well as other government organizations, industry, and academia to store and disseminate multiple intelligence (Multi-INT) datasets collected at field exercises and demonstrations, and to facilitate research and development (R and D), and advancement of analytical tools and algorithms supporting the Intelligence, Surveillance, and Reconnaissance (ISR) community. The AODR provides a potential central repository for standards compliant datasets to serve as the "go-to" location for lessons-learned and reference products. Many of the AODR datasets have associated ground truth and other metadata which provides a rich and robust data suite for researchers to develop, test, and refine their algorithms. Researchers download the test data to their own environments using a sophisticated web interface. The AODR allows researchers to request copies of stored datasets and for the government to process the requests and approvals in an automated fashion. Access to the AODR requires two-factor authentication in the form of a Common Access Card (CAC) or External Certificate Authority (ECA)
Approach to plant automation with evolving technology
International Nuclear Information System (INIS)
White, J.D.
1989-01-01
The US Department of Energy has provided support to Oak Ridge National Laboratory in order to pursue research leading to advanced, automated control of new innovative liquid-metal-cooled nuclear power plants. The purpose of this effort is to conduct research that will help to ensure improved operability, reliability, and safety for advanced LMRs. The plan adopted to achieve these program goals in an efficient and timely manner consists of utilizing, and advancing where required, state-of-the-art controls technology through close interaction with other national laboratories, universities, industry and utilities. A broad range of applications for the control systems strategies and the design environment developed in the course of this program is likely. A natural evolution of automated control in nuclear power plants is envisioned by ORNL to be a phased transition from today's situation of some analog control at the subsystem level with significant operator interaction to the future capability for completely automated digital control with operator supervision. The technical accomplishments provided by this program will assist the industry to accelerate this transition and provide greater economy and safety. The development of this transition to advanced, automated control system designs is expected to have extensive benefits in reduced operating costs, fewer outages, enhanced safety, improved licensability, and improved public acceptance for commercial nuclear power plants. 24 refs
Approach to plant automation with evolving technology
International Nuclear Information System (INIS)
White, J.D.
1989-01-01
This paper reports that the U.S. Department of Energy has provided support to Oak Ridge National Laboratory in order to pursue research leading to advanced, automated control of new innovative liquid-metal-cooled nuclear power plants. The purpose of this effort is to conduct research that will help to ensure improved operability, reliability, and safety for advanced LMRs. The plan adopted to achieve these program goals in an efficient and timely manner consists of utilizing, and advancing where required, state-of-the art controls technology through close interaction with other national laboratories, universities, industry and utilities. A broad range of applications for the control systems strategies and the design environment developed in the course of this program is likely. A natural evolution of automated control in nuclear power plants is envisioned by ORNL to be a phased transition from today's situation of some analog control at the subsystem level with significant operator interaction to the future capability for completely automated digital control with operator supervision. The technical accomplishments provided by this program will assist the industry to accelerate this transition and provide greater economy and safety. The development of this transition to advanced, automated control system designs is expected to have extensive benefits in reduced operating costs, fewer outages, enhanced safety, improved licensability, and improved public acceptance for commercial nuclear power plants
Computer-automated neutron activation analysis system
International Nuclear Information System (INIS)
Minor, M.M.; Garcia, S.R.
1983-01-01
An automated delayed neutron counting and instrumental neutron activation analysis system has been developed at Los Alamos National Laboratory's Omega West Reactor (OWR) to analyze samples for uranium and 31 additional elements with a maximum throughput of 400 samples per day. 5 references
Clinical utility of an automated instrument for gram staining single slides.
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-06-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.
Knowledge-based automated radiopharmaceutical manufacturing for Positron Emission Tomography
International Nuclear Information System (INIS)
Alexoff, D.L.
1991-01-01
This article describes the application of basic knowledge engineering principles to the design of automated synthesis equipment for radiopharmaceuticals used in Positron Emission Tomography (PET). Before discussing knowledge programming, an overview of the development of automated radiopharmaceutical synthesis systems for PET will be presented. Since knowledge systems will rely on information obtained from machine transducers, a discussion of the uses of sensory feedback in today's automated systems follows. Next, the operation of these automated systems is contrasted to radiotracer production carried out by chemists, and the rationale for and basic concepts of knowledge-based programming are explained. Finally, a prototype knowledge-based system supporting automated radiopharmaceutical manufacturing of 18FDG at Brookhaven National Laboratory (BNL) is described using 1stClass, a commercially available PC-based expert system shell
Developing a strategy for a regulated electronic bioanalytical laboratory.
McDowall, R D
2014-01-01
This perspective article considers the strategy, design and implementation of an electronic bioanalytical laboratory working to GLP and/or GCP regulations. There are a range of available automated systems and laboratory informatics that could be implemented and integrated to make an electronic laboratory. However, which are the appropriate ones to select and what is realistic and cost-effective for an individual laboratory? The answer is to develop an overall automation strategy that is updated periodically after each system or application has been implemented to assess if the strategy is still valid or needs to be changed. As many laboratory informatics applications have functional overlap or convergence, for example, Laboratory Information Management System, Electronic Laboratory Notebook, and Instrument and Chromatography Data Systems, the decision of which application performs a specific task needs to be carefully considered in the overall strategy. Ensuring data integrity and regulatory compliance, especially in light of a number of recent falsification cases, is a mandatory consideration for the overall strategy for an electronic bioanalytical laboratory submitting data to regulatory authorities.
Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara
2014-08-01
Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.
Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.
2013-01-01
Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273
Directory of Open Access Journals (Sweden)
Swee Jin Tan
Full Text Available Library preparation for next-generation DNA sequencing (NGS remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.
Automated, High Temperature Furnace for Glovebox Operation
International Nuclear Information System (INIS)
Neikirk, K.
2001-01-01
The U.S. Department of Energy will immobilize excess plutonium in the proposed Plutonium Immobilization Plant (PIP) at the Savannah River Site (SRS) as part of a two track approach for the disposition of weapons usable plutonium. As such, the Department of Energy is funding a development and testing effort for the PIP. This effort is being performed jointly by Lawrence Livermore National Laboratory (LLNL), Westinghouse Savannah River Company (WSRC), Pacific Northwest National Laboratory (PNNL), and Argonne National Laboratory (ANL). The Plutonium Immobilization process involves the disposition of excess plutonium by incorporation into ceramic pucks. As part of the immobilization process, furnaces are needed for sintering the ceramic pucks. The furnace being developed for puck sintering is an automated, bottom loaded furnace with insulting package and resistance heating elements located within a nuclear glovebox. Other furnaces considered for the application include retort furnaces and pusher furnaces. This paper, in part, will discuss the furnace technologies considered and furnace technology selected to support reliable puck sintering in a glovebox environment. Due to the radiation levels and contamination associated with the plutonium material, the sintering process will be fully automated and contained within nuclear material gloveboxes. As such, the furnace currently under development incorporates water and air cooling to minimize heat load to the glovebox. This paper will describe the furnace equipment and systems needed to employ a fully automated puck sintering process within nuclear gloveboxes as part of the Plutonium Immobilization Plant
Directory of Open Access Journals (Sweden)
Notas George
2002-08-01
Full Text Available Abstract Background Antioxidant molecules, which scavenge free radical species to prevent or delay oxidative damage of important macromolecules, membrane lipids and lipoproteins, are prevalent in plasma and other biological fluids. Among them, bilirubin, uric acid and protein thiols are the major endogenous antioxidants, while vitamins C and E, as well as a number of food-derived (polyaromatic substances, belonging to stilbens, flavonoids and phenolic acids, are the main classes of nutritional antioxidants. Assays for total antioxidant capacity in plasma differ in their type of oxidation source, target and measurement used to detect the oxidized product. Methods In the present work we present an automated assay for the estimation of blood total antioxidant capacity (TAC assay, based on the crocin bleaching (oxidation method. This method was adapted on a modern autoanalyzer, was linear over a wide range of values (0–3 mmol/L, and performed using an end point measurement. Results The TAC method presented a linear correlation with another automated commercial Total Antioxidant Status (TAS test. Detection of the interference of different metabolites revealed a significant participation of TAC from uric acid, bilirubin, albumin, a minor interference from ascorbic acid, and no interference from hemoglobin. TAC was not modified by two freeze/thawing cycles, and was stable in samples stored at room temperature for 4 hours. K-EDTA and heparin were the best anticoagulants, while citrate decreased TAC by 20%. Reference values derived from samples of normal blood donors was 1.175 ± 0.007 mmol/L (mean ± SEM, while a diet rich in antioxidants more than doubled this value. Conclusions The proposed TAC assay, is fully automated, stable and reliable, and could be of value in the estimation of the AC of plasma. It is further proposed to calculate the antioxidant capacity of plasma after a subtraction of all interference deriving from endogenous and
Material handling for the Los Alamos National Laboratory Nuclear Storage Facility
International Nuclear Information System (INIS)
Pittman, P.; Roybal, J.; Durrer, R.; Gordon, D.
1999-01-01
This paper will present the design and application of material handling and automation systems currently being developed for the Los Alamos National Laboratory (LANL) Nuclear Material Storage Facility (NMSF) renovation project. The NMSF is a long-term storage facility for nuclear material in various forms. The material is stored within tubes in a rack called a basket. The material handling equipment range from simple lift assist devices to more sophisticated fully automated robots, and are split into three basic systems: a Vault Automation System, an NDA automation System, and a Drum handling System. The Vault Automation system provides a mechanism to handle a basket of material cans and to load/unload storage tubes within the material vault. In addition, another robot is provided to load/unload material cans within the baskets. The NDA Automation System provides a mechanism to move material within the small canister NDA laboratory and to load/unload the NDA instruments. The Drum Handling System consists of a series of off the shelf components used to assist in lifting heavy objects such as pallets of material or drums and barrels
Technology Transfer Opportunities: Automated Ground-Water Monitoring
Smith, Kirk P.; Granato, Gregory E.
1997-01-01
Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.
Mockup of an automated material transport system for remote handling
International Nuclear Information System (INIS)
Porter, M.L.
1992-01-01
The automated material transport system (AMTS) was conceived for the transport of samples within the material and process control laboratory (MPCL), located in the plutonium processing building of the special isotope separation (SIS) facility. The MPCL was designed with a dry sample handling laboratory and a wet chemistry analysis laboratory. Each laboratory contained several processing glove boxes. The function of the AMTS was to automate the handling of materials, multiple process samples, and bulky items between process stations with a minimum of operator intervention and with a minimum of waiting periods and nonproductive activities. The AMTS design requirements, design verification mockup plan, and AMTS mockup procurement specification were established prior to cancellation of the SIS project. Due to the AMTS's flexibility, the need for technology development, and applicability to other US Department of Energy facilities, mockup of the AMTS continued. This paper discusses the system design features, capabilities, and results of initial testing
Biocoder: A programming language for standardizing and automating biology protocols.
Ananthanarayanan, Vaishnavi; Thies, William
2010-11-08
Published descriptions of biology protocols are often ambiguous and incomplete, making them difficult to replicate in other laboratories. However, there is increasing benefit to formalizing the descriptions of protocols, as laboratory automation systems (such as microfluidic chips) are becoming increasingly capable of executing them. Our goal in this paper is to improve both the reproducibility and automation of biology experiments by using a programming language to express the precise series of steps taken. We have developed BioCoder, a C++ library that enables biologists to express the exact steps needed to execute a protocol. In addition to being suitable for automation, BioCoder converts the code into a readable, English-language description for use by biologists. We have implemented over 65 protocols in BioCoder; the most complex of these was successfully executed by a biologist in the laboratory using BioCoder as the only reference. We argue that BioCoder exposes and resolves ambiguities in existing protocols, and could provide the software foundations for future automation platforms. BioCoder is freely available for download at http://research.microsoft.com/en-us/um/india/projects/biocoder/. BioCoder represents the first practical programming system for standardizing and automating biology protocols. Our vision is to change the way that experimental methods are communicated: rather than publishing a written account of the protocols used, researchers will simply publish the code. Our experience suggests that this practice is tractable and offers many benefits. We invite other researchers to leverage BioCoder to improve the precision and completeness of their protocols, and also to adapt and extend BioCoder to new domains.
Automation of (64)Cu production at Turku PET Centre.
Elomaa, Viki-Veikko; Jurttila, Jori; Rajander, Johan; Solin, Olof
2014-07-01
At Turku PET Centre automation for handling solid targets for the production of (64)Cu has been built. The system consists of a module for moving the target from the irradiation position into a lead transport shield and a robotic-arm assisted setup for moving the target within radiochemistry laboratory. The main motivation for designing automation arises from radiation hygiene. Copyright © 2014 Elsevier Ltd. All rights reserved.
Prevalence of discordant microscopic changes with automated CBC analysis
Directory of Open Access Journals (Sweden)
Fabiano de Jesus Santos
2014-12-01
Full Text Available Introduction:The most common cause of diagnostic error is related to errors in laboratory tests as well as errors of results interpretation. In order to reduce them, the laboratory currently has modern equipment which provides accurate and reliable results. The development of automation has revolutionized the laboratory procedures in Brazil and worldwide.Objective:To determine the prevalence of microscopic changes present in blood slides concordant and discordant with results obtained using fully automated procedures.Materials and method:From January to July 2013, 1,000 hematological parameters slides were analyzed. Automated analysis was performed on last generation equipment, which methodology is based on electrical impedance, and is able to quantify all the figurative elements of the blood in a universe of 22 parameters. The microscopy was performed by two experts in microscopy simultaneously.Results:The data showed that only 42.70% were concordant, comparing with 57.30% discordant. The main findings among discordant were: Changes in red blood cells 43.70% (n = 250, white blood cells 38.46% (n = 220, and number of platelet 17.80% (n = 102.Discussion:The data show that some results are not consistent with clinical or physiological state of an individual, and cannot be explained because they have not been investigated, which may compromise the final diagnosis.Conclusion:It was observed that it is of fundamental importance that the microscopy qualitative analysis must be performed in parallel with automated analysis in order to obtain reliable results, causing a positive impact on the prevention, diagnosis, prognosis, and therapeutic follow-up.
An Intelligent Automation Platform for Rapid Bioprocess Design.
Wu, Tianyi; Zhou, Yuhong
2014-08-01
Bioprocess development is very labor intensive, requiring many experiments to characterize each unit operation in the process sequence to achieve product safety and process efficiency. Recent advances in microscale biochemical engineering have led to automated experimentation. A process design workflow is implemented sequentially in which (1) a liquid-handling system performs high-throughput wet lab experiments, (2) standalone analysis devices detect the data, and (3) specific software is used for data analysis and experiment design given the user's inputs. We report an intelligent automation platform that integrates these three activities to enhance the efficiency of such a workflow. A multiagent intelligent architecture has been developed incorporating agent communication to perform the tasks automatically. The key contribution of this work is the automation of data analysis and experiment design and also the ability to generate scripts to run the experiments automatically, allowing the elimination of human involvement. A first-generation prototype has been established and demonstrated through lysozyme precipitation process design. All procedures in the case study have been fully automated through an intelligent automation platform. The realization of automated data analysis and experiment design, and automated script programming for experimental procedures has the potential to increase lab productivity. © 2013 Society for Laboratory Automation and Screening.
An analog integrated circuit design laboratory
Mondragon-Torres, A.F.; Mayhugh, Jr.; Pineda de Gyvez, J.; Silva-Martinez, J.; Sanchez-Sinencio, E.
2003-01-01
We present the structure of an analog integrated circuit design laboratory to instruct at both, senior undergraduate and entry graduate levels. The teaching material includes: a laboratory manual with analog circuit design theory, pre-laboratory exercises and circuit design specifications; a reference web page with step by step instructions and examples; the use of mathematical tools for automation and analysis; and state of the art CAD design tools in use by industry. Upon completion of the ...
Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-01-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348
Design Automation in Synthetic Biology.
Appleton, Evan; Madsen, Curtis; Roehner, Nicholas; Densmore, Douglas
2017-04-03
Design automation refers to a category of software tools for designing systems that work together in a workflow for designing, building, testing, and analyzing systems with a target behavior. In synthetic biology, these tools are called bio-design automation (BDA) tools. In this review, we discuss the BDA tools areas-specify, design, build, test, and learn-and introduce the existing software tools designed to solve problems in these areas. We then detail the functionality of some of these tools and show how they can be used together to create the desired behavior of two types of modern synthetic genetic regulatory networks. Copyright © 2017 Cold Spring Harbor Laboratory Press; all rights reserved.
International Nuclear Information System (INIS)
O'Hara, Matthew J.; Durst, Philip C.; Grate, Jay W.; Devol, Timothy A.; Egorov, Oleg; Clements, John P.
2008-01-01
Identification and quantification of specific alpha- and beta-emitting radionuclides in complex liquid matrices is highly challenging, and is typically accomplished through laborious wet chemical sample preparation and separations followed by analysis using a variety of detection methodologies (e.g., liquid scintillation, gas proportional counting, alpha energy analysis, mass spectrometry). Analytical results may take days or weeks to report. Chains of custody and sample security measures may also complicate or slow the analytical process. When an industrial process-scale plant requires the monitoring of specific radionuclides as an indication of the composition of its feed stream or of plant performance, radiochemical measurements must be fast, accurate, and reliable. Scientists at Pacific Northwest National Laboratory have assembled a fully automated prototype Process Monitor instrument capable of a variety of tasks: automated sampling directly from a feed stream, sample digestion/analyte redox adjustment, chemical separations, radiochemical detection and data analysis/reporting. The system is compact, its components are fluidically inter-linked, and analytical results could be immediately transmitted to on- or off-site locations. The development of a rapid radiochemical Process Monitor for 99Tc in Hanford tank waste processing streams, capable of performing several measurements per hour, will be discussed in detail. More recently, the automated platform was modified to perform measurements of 90Sr in Hanford tank waste stimulant. The system exemplifies how automation could be integrated into reprocessing facilities to support international nuclear safeguards needs
van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier
2016-08-08
Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce
Automation of analytical processes. A tool for higher efficiency and safety
International Nuclear Information System (INIS)
Groll, P.
1976-01-01
The analytical laboratory of a radiochemical facility is usually faced with the fact that numerous analyses of a similar type must be routinely carried out. Automation of such routine analytical procedures helps in increasing the efficiency and safety of the work. A review of the requirements for automation and its advantages is given and demonstrated on three examples. (author)
Doping control in Japan. An automated extraction procedure for the doping test.
Nakajima, T.; Matsumoto, T.
1976-01-01
Horse racing in Japan consists of two systems, the National (10 racecourses) and the Regional public racing (32 racecourses) having about 2,500 racing meetings in total per year. Urine or saliva samples for dope testing are collected by the officials from thw winner, second and third, and transported to the laboratory in a frozen state. In 1975, 76, 117 samples were analyzed by this laboratory. The laboratory provides the following four methods of analysis, which are variously combined by request. (1) Method for detection of drugs extracted by chloroform from alkalinized sample. (2) Methods for detection of camphor and its derivatives. (3) Method for detection of barbiturates. (4) Method for detection of ethanol. These methods consist of screening, mainly by thin layer chromatography and confirmatory tests using ultra violet spectrophotometry, gas chromatography and mass spectrometry combined with gas chromatography. In the screening test of doping drugs, alkalinized samples are extracted with chloroform. In order to automate the extraction procedure, the authors contrived a new automatic extractor. They also devised a means of pH adjustment of horse urine by using buffer solution and an efficient mechanism of evaporation of organic solvent. Analytical data obtained by the automatic extractor are presented in this paper. In 1972, we started research work to automate the extraction procedure in method (1) above, and the Automatic Extractor has been in use in routine work since last July. One hundred and twnety samples per hour are extracted automatically by three automatic extractors. The analytical data using this apparatus is presented below. PMID:1000163
21 CFR 866.4700 - Automated fluorescence in situ hybridization (FISH) enumeration systems.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated fluorescence in situ hybridization (FISH... Laboratory Equipment and Reagents § 866.4700 Automated fluorescence in situ hybridization (FISH) enumeration... Hybridization (FISH) Enumeration Systems.” See § 866.1(e) for the availability of this guidance document. [70 FR...
Brewster, L.; Johnston, A.; Howard, R.; Mitchell, J.; Cryan, S.
2007-01-01
The Exploration Systems Architecture defines missions that require rendezvous, proximity operations, and docking (RPOD) of two spacecraft both in Low Earth Orbit (LEO) and in Low Lunar Orbit (LLO). Uncrewed spacecraft must perform automated and/or autonomous rendezvous, proximity operations and docking operations (commonly known as AR&D). The crewed missions may also perform rendezvous and docking operations and may require different levels of automation and/or autonomy, and must provide the crew with relative navigation information for manual piloting. The capabilities of the RPOD sensors are critical to the success of the Exploration Program. NASA has the responsibility to determine whether the Crew Exploration Vehicle (CEV) contractor proposed relative navigation sensor suite will meet the requirements. The relatively low technology readiness level of AR&D relative navigation sensors has been carried as one of the CEV Project's top risks. The AR&D Sensor Technology Project seeks to reduce the risk by the testing and analysis of selected relative navigation sensor technologies through hardware-in-the-loop testing and simulation. These activities will provide the CEV Project information to assess the relative navigation sensors maturity as well as demonstrate test methods and capabilities. The first year of this project focused on a series of"pathfinder" testing tasks to develop the test plans, test facility requirements, trajectories, math model architecture, simulation platform, and processes that will be used to evaluate the Contractor-proposed sensors. Four candidate sensors were used in the first phase of the testing. The second phase of testing used four sensors simultaneously: two Marshall Space Flight Center (MSFC) Advanced Video Guidance Sensors (AVGS), a laser-based video sensor that uses retroreflectors attached to the target vehicle, and two commercial laser range finders. The multi-sensor testing was conducted at MSFC's Flight Robotics Laboratory (FRL
Productivity standards for histology laboratories.
Buesa, René J
2010-04-01
The information from 221 US histology laboratories (histolabs) and 104 from 24 other countries with workloads from 600 to 116 000 cases per year was used to calculate productivity standards for 23 technical and 27 nontechnical tasks and for 4 types of work flow indicators. The sample includes 254 human, 40 forensic, and 31 veterinary pathology services. Statistical analyses demonstrate that most productivity standards are not different between services or worldwide. The total workload for the US human pathology histolabs averaged 26 061 cases per year, with 54% between 10 000 and less than 30 000. The total workload for 70% of the histolabs from other countries was less than 20 000, with an average of 15 226 cases per year. The fundamental manual technical tasks in the histolab and their productivity standards are as follows: grossing (14 cases per hour), cassetting (54 cassettes per hour), embedding (50 blocks per hour), and cutting (24 blocks per hour). All the other tasks, each with their own productivity standards, can be completed by auxiliary staff or using automatic instruments. Depending on the level of automation of the histolab, all the tasks derived from a workload of 25 cases will require 15.8 to 17.7 hours of work completed by 2.4 to 2.7 employees with 18% of their working time not directly dedicated to the production of diagnostic slides. This article explains how to extrapolate this productivity calculation for any workload and different levels of automation. The overall performance standard for all the tasks, including 8 hours for automated tissue processing, is 3.2 to 3.5 blocks per hour; and its best indicator is the value of the gross work flow productivity that is essentially dependent on how the work is organized. This article also includes productivity standards for forensic and veterinary histolabs, but the staffing benchmarks for histolabs will be the subject of a separate article. Copyright 2010 Elsevier Inc. All rights reserved.
AUTOMATION OF CHAMPAGNE WINES PROCESS IN SPARKLING WINE PRESSURE TANK
Directory of Open Access Journals (Sweden)
E. V. Lukyanchuk
2016-08-01
Full Text Available The wine industry is now successfully solved the problem for the implementation of automation receiving points of grapes, crushing and pressing departments installation continuous fermentation work, blend tanks, production lines ordinary Madeira continuously working plants for ethyl alcohol installations champagne wine in continuous flow, etc. With the development of automation of technological progress productivity winemaking process develops in the following areas: organization of complex avtomatization sites grape processing with bulk transportation of the latter; improving the quality and durability of wines by the processing of a wide applying wine cold and heat, as well as technical and microbiological control most powerful automation equipment; the introduction of automated production processes of continuous technical champagne, sherry wine and cognac alcohol madery; the use of complex automation auxiliary production sites (boilers, air conditioners, refrigeration unitsand other.; complex avtomatization creation of enterprises, and sites manufactory bottling wines. In the wine industry developed more sophisticated schemes of automation and devices that enable the transition to integrated production automation, will create, are indicative automated enterprise serving for laboratories to study of the main problems of automation of production processes of winemaking.
Remote systems and automation in radioactive waste package handling
International Nuclear Information System (INIS)
Gneiting, B.C.; Hayward, M.L.
1987-01-01
A proof-of-principle test was conducted at the Hanford Engineering Development Laboratory (HEDL) to demonstrate the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. This development testing showed feasibility of performing critical cask receipt, preparation, and unloading operations from a single control station using remote controls and indirect viewing. Using robotics and remote automation in a cask handling system can result in lower personnel exposure levels and cask turnaround times while maintaining operational flexibility. An automated cask handling system presents a flexible state-of-the-art, cost effective alternative solution to hands-on methods that have been used in the past
The Weapons Laboratory Technical Library: Automating with ’Stilas’
1990-03-01
version of the system to LC in October 1988. -X- A small business specializing in library automation, SIRSI was founded in 1979 by library and...computer specialists, and has a strong reputation based upon the success of their UNIX-based Unicorn Collection Management System. SIRSI offers a complete...system based on the Unicorn and BRS/ Search systems. The contracted STILAS package includes UNISYS hardware, software written in the C language
Automated remedial assessment methodology software system
International Nuclear Information System (INIS)
Whiting, M.; Wilkins, M.; Stiles, D.
1994-11-01
The Automated Remedial Analysis Methodology (ARAM) software system has been developed by the Pacific Northwest Laboratory to assist the U.S. Department of Energy (DOE) in evaluating cleanup options for over 10,000 contaminated sites across the DOE complex. The automated methodology comprises modules for decision logic diagrams, technology applicability and effectiveness rules, mass balance equations, cost and labor estimating factors and equations, and contaminant stream routing. ARAM is used to select technologies for meeting cleanup targets; determine the effectiveness of the technologies in destroying, removing, or immobilizing contaminants; decide the nature and amount of secondary waste requiring further treatment; and estimate the cost and labor involved when applying technologies
Flexible test automation a software framework for easily developing measurement applications
Arpaia, Pasquale; De Matteis, Ernesto
2014-01-01
In laboratory management of an industrial test division, a test laboratory, or a research center, one of the main activities is producing suitable software for automatic benches by satisfying a given set of requirements. This activity is particularly costly and burdensome when test requirements are variable over time. If the batches of objects have small size and frequent occurrence, the activity of measurement automation becomes predominating with respect to the test execution. Flexible Test Automation shows the development of a software framework as a useful solution to satisfy this exigency. The framework supports the user in producing measurement applications for a wide range of requirements with low effort and development time.
Robust automated knowledge capture.
Energy Technology Data Exchange (ETDEWEB)
Stevens-Adams, Susan Marie; Abbott, Robert G.; Forsythe, James Chris; Trumbo, Michael Christopher Stefan; Haass, Michael Joseph; Hendrickson, Stacey M. Langfitt
2011-10-01
This report summarizes research conducted through the Sandia National Laboratories Robust Automated Knowledge Capture Laboratory Directed Research and Development project. The objective of this project was to advance scientific understanding of the influence of individual cognitive attributes on decision making. The project has developed a quantitative model known as RumRunner that has proven effective in predicting the propensity of an individual to shift strategies on the basis of task and experience related parameters. Three separate studies are described which have validated the basic RumRunner model. This work provides a basis for better understanding human decision making in high consequent national security applications, and in particular, the individual characteristics that underlie adaptive thinking.
Establishment of automated culture system for murine induced pluripotent stem cells
Directory of Open Access Journals (Sweden)
Koike Hiroyuki
2012-11-01
Full Text Available Abstract Background Induced pluripotent stem (iPS cells can differentiate into any cell type, which makes them an attractive resource in fields such as regenerative medicine, drug screening, or in vitro toxicology. The most important prerequisite for these industrial applications is stable supply and uniform quality of iPS cells. Variation in quality largely results from differences in handling skills between operators in laboratories. To minimize these differences, establishment of an automated iPS cell culture system is necessary. Results We developed a standardized mouse iPS cell maintenance culture, using an automated cell culture system housed in a CO2 incubator commonly used in many laboratories. The iPS cells propagated in a chamber uniquely designed for automated culture and showed specific colony morphology, as for manual culture. A cell detachment device in the system passaged iPS cells automatically by dispersing colonies to single cells. In addition, iPS cells were passaged without any change in colony morphology or expression of undifferentiated stem cell markers during the 4 weeks of automated culture. Conclusions Our results show that use of this compact, automated cell culture system facilitates stable iPS cell culture without obvious effects on iPS cell pluripotency or colony-forming ability. The feasibility of iPS cell culture automation may greatly facilitate the use of this versatile cell source for a variety of biomedical applications.
International Nuclear Information System (INIS)
Astakhova, N.V.; Beskrovnyj, A.I.; Bogdzel', A.A.; Butorin, P.E.; Vasilovskij, S.G.; Gundorin, N.A.; Zlokazov, V.B.; Kutuzov, S.A.; Salamatin, I.M.; Shvetsov, V.N.
2003-01-01
An instrumental software complex for automation of spectrometry (AS) that enables prompt realization of experiment automation systems for spectrometers, which use data buferisation, has been developed. In the development new methods of programming and building of automation systems together with novel net technologies were employed. It is suggested that programs to schedule and conduct experiments should be based on the parametric model of the spectrometer, the approach that will make it possible to write programs suitable for any FLNP (Frank Laboratory of Neutron Physics) spectrometer and experimental technique applied and use different hardware interfaces for introducing the spectrometric data into the data acquisition system. The article describes the possibilities provided to the user in the field of scheduling and control of the experiment, data viewing, and control of the spectrometer parameters. The possibility of presenting the current spectrometer state, programs and the experimental data in the Internet in the form of dynamically formed protocols and graphs, as well as of the experiment control via the Internet is realized. To use the means of the Internet on the side of the client, applied programs are not needed. It suffices to know how to use the two programs to carry out experiments in the automated mode. The package is designed for experiments in condensed matter and nuclear physics and is ready for using. (author)
Understanding Is Key: An Analysis of Factors Pertaining to Trust in a Real-World Automation System.
Balfe, Nora; Sharples, Sarah; Wilson, John R
2018-06-01
This paper aims to explore the role of factors pertaining to trust in real-world automation systems through the application of observational methods in a case study from the railway sector. Trust in automation is widely acknowledged as an important mediator of automation use, but the majority of the research on automation trust is based on laboratory work. In contrast, this work explored trust in a real-world setting. Experienced rail operators in four signaling centers were observed for 90 min, and their activities were coded into five mutually exclusive categories. Their observed activities were analyzed in relation to their reported trust levels, collected via a questionnaire. The results showed clear differences in activity, even when circumstances on the workstations were very similar, and significant differences in some trust dimensions were found between groups exhibiting different levels of intervention and time not involved with signaling. Although the empirical, lab-based studies in the literature have consistently found that reliability and competence of the automation are the most important aspects of trust development, understanding of the automation emerged as the strongest dimension in this study. The implications are that development and maintenance of trust in real-world, safety-critical automation systems may be distinct from artificial laboratory automation. The findings have important implications for emerging automation concepts in diverse industries including highly automated vehicles and Internet of things.
TARDIS: An Automation Framework for JPL Mission Design and Navigation
Roundhill, Ian M.; Kelly, Richard M.
2014-01-01
Mission Design and Navigation at the Jet Propulsion Laboratory has implemented an automation framework tool to assist in orbit determination and maneuver design analysis. This paper describes the lessons learned from previous automation tools and how they have been implemented in this tool. In addition this tool has revealed challenges in software implementation, testing, and user education. This paper describes some of these challenges and invites others to share their experiences.
CCD characterization and measurements automation
International Nuclear Information System (INIS)
Kotov, I.V.; Frank, J.; Kotov, A.I.; Kubanek, P.; O'Connor, P.; Prouza, M.; Radeka, V.; Takacs, P.
2012-01-01
Modern mosaic cameras have grown both in size and in number of sensors. The required volume of sensor testing and characterization has grown accordingly. For camera projects as large as the LSST, test automation becomes a necessity. A CCD testing and characterization laboratory was built and is in operation for the LSST project. Characterization of LSST study contract sensors has been performed. The characterization process and its automation are discussed, and results are presented. Our system automatically acquires images, populates a database with metadata information, and runs express analysis. This approach is illustrated on 55 Fe data analysis. 55 Fe data are used to measure gain, charge transfer efficiency and charge diffusion. Examples of express analysis results are presented and discussed.
Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N
2017-10-01
Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C
2006-12-20
Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the
2018-01-01
ARL-TR-8270 ● JAN 2018 US Army Research Laboratory An Automated Energy Detection Algorithm Based on Morphological Filter...Automated Energy Detection Algorithm Based on Morphological Filter Processing with a Modified Watershed Transform by Kwok F Tom Sensors and Electron...1 October 2016–30 September 2017 4. TITLE AND SUBTITLE An Automated Energy Detection Algorithm Based on Morphological Filter Processing with a
Automation in biological crystallization.
Stewart, Patrick Shaw; Mueller-Dieckmann, Jochen
2014-06-01
Crystallization remains the bottleneck in the crystallographic process leading from a gene to a three-dimensional model of the encoded protein or RNA. Automation of the individual steps of a crystallization experiment, from the preparation of crystallization cocktails for initial or optimization screens to the imaging of the experiments, has been the response to address this issue. Today, large high-throughput crystallization facilities, many of them open to the general user community, are capable of setting up thousands of crystallization trials per day. It is thus possible to test multiple constructs of each target for their ability to form crystals on a production-line basis. This has improved success rates and made crystallization much more convenient. High-throughput crystallization, however, cannot relieve users of the task of producing samples of high quality. Moreover, the time gained from eliminating manual preparations must now be invested in the careful evaluation of the increased number of experiments. The latter requires a sophisticated data and laboratory information-management system. A review of the current state of automation at the individual steps of crystallization with specific attention to the automation of optimization is given.
International Nuclear Information System (INIS)
Rzeszutko, C.; Johnson, C.R.; Monagle, M.; Klatt, L.N.
1997-10-01
The Chemical Analysis Automation (CAA) program is developing a standardized modular automation strategy for chemical analysis. In this automation concept, analytical chemistry is performed with modular building blocks that correspond to individual elements of the steps in the analytical process. With a standardized set of behaviors and interactions, these blocks can be assembled in a 'plug and play' manner into a complete analysis system. These building blocks, which are referred to as Standard Laboratory Modules (SLM), interface to a host control system that orchestrates the entire analytical process, from sample preparation through data interpretation. The integrated system is called a Standard Analysis Method (SAME). A SAME for the automated determination of Polychlorinated Biphenyls (PCB) in soils, assembled in a mobile laboratory, is undergoing extensive testing and validation. The SAME consists of the following SLMs: a four channel Soxhlet extractor, a High Volume Concentrator, column clean up, a gas chromatograph, a PCB data interpretation module, a robot, and a human- computer interface. The SAME is configured to meet the requirements specified in U.S. Environmental Protection Agency's (EPA) SW-846 Methods 3541/3620A/8082 for the analysis of pcbs in soils. The PCB SAME will be described along with the developmental test plan. Performance data obtained during developmental testing will also be discussed
Use of laboratory robots in the automation of a urine plutonium bioassay
International Nuclear Information System (INIS)
Gonzales, E.R.; Moss, W.D.; Rodriguez, R.; Martinez, G.M.
1986-01-01
Determination of plutonium in urine is a routine procedure performed at Los Alamos. Samples are taken from the many workers who handle plutonium in their day to day activities and from those individuals whose jobs may bring them into contact with this metal. The analytical procedure used is based on alkaline earth phosphate precipitation that coprecipitates the plutonium. This procedure gives excellent results but it involves many manipulative steps and the chances for human error are ever present. In order to eliminate potential human error and decrease analysis time this procedure was automated using a Zymark Corporation robotic workcell. The developmental work for the automation process was divided into two parts: robot programmatic needs - software and hardware, and chemical modifications of existing methods for utilization with the robotic system. The optimum integration of these developments are discussed in this paper
Remote systems and automation in radioactive waste package handling
International Nuclear Information System (INIS)
Gneiting, B.C.; Hayward, M.L.
1987-01-01
A proof-of-principle test was conducted at the Hanford Engineering Development Laboratory (HEDL) to demonstrate the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. This development testing showed feasibility of performing critical cask receipt, preparation, and unloading operations from a single control station using remote controls and indirect viewing. Using robotics and remote automation in a cask handling system can result in lower personnel exposure levels and cask turnaround times while maintaining operational flexibility. An automated cask handling system presents a flexible state-of-the-art, cost effective alternative solution to hands-on methods that have been used in the past. 7 refs., 13 figs
Automation of the dicentric chromosome assay and related assays
International Nuclear Information System (INIS)
Balajee, Adayabalam S.; Dainiak, Nicholas
2016-01-01
Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed
Computer automated mass spectrometer for isotope analysis on gas samples
International Nuclear Information System (INIS)
Pamula, A.; Kaucsar, M.; Fatu, C.; Ursu, D.; Vonica, D.; Bendea, D.; Muntean, F.
1998-01-01
A low resolution, high precision instrument was designed and realized in the mass spectrometry laboratory of the Institute of Isotopic and Molecular Technology, Cluj-Napoca. The paper presents the vacuum system, the sample inlet system, the ion source, the magnetic analyzer and the ion collector. The instrument is almost completely automated. There are described the analog-to-digital conversion circuits, the local control microcomputer, the automation systems and the performance checking. (authors)
Application of robotic principles to laboratory automation
International Nuclear Information System (INIS)
Pierce, T.B.
1986-01-01
The possibility of applying robotic techniques to some laboratory tasks is considered. A low-cost rig was constructed, at AERE Harwell, to examine the performance of a number of low-cost commercial robots. The importance of justifying the costs of introducing robotic systems and the difficulty of analysing the cost-benefit of robotic over mechanical systems is stressed. (UK)
Automated Processing of Plasma Samples for Lipoprotein Separation by Rate-Zonal Ultracentrifugation.
Peters, Carl N; Evans, Iain E J
2016-12-01
Plasma lipoproteins are the primary means of lipid transport among tissues. Defining alterations in lipid metabolism is critical to our understanding of disease processes. However, lipoprotein measurement is limited to specialized centers. Preparation for ultracentrifugation involves the formation of complex density gradients that is both laborious and subject to handling errors. We created a fully automated device capable of forming the required gradient. The design has been made freely available for download by the authors. It is inexpensive relative to commercial density gradient formers, which generally create linear gradients unsuitable for rate-zonal ultracentrifugation. The design can easily be modified to suit user requirements and any potential future improvements. Evaluation of the device showed reliable peristaltic pump accuracy and precision for fluid delivery. We also demonstrate accurate fluid layering with reduced mixing at the gradient layers when compared to usual practice by experienced laboratory personnel. Reduction in layer mixing is of critical importance, as it is crucial for reliable lipoprotein separation. The automated device significantly reduces laboratory staff input and reduces the likelihood of error. Overall, this device creates a simple and effective solution to formation of complex density gradients. © 2015 Society for Laboratory Automation and Screening.
Understanding Is Key: An Analysis of Factors Pertaining to Trust in a Real-World Automation System
Balfe, Nora; Sharples, Sarah; Wilson, John R.
2018-01-01
Objective: This paper aims to explore the role of factors pertaining to trust in real-world automation systems through the application of observational methods in a case study from the railway sector. Background: Trust in automation is widely acknowledged as an important mediator of automation use, but the majority of the research on automation trust is based on laboratory work. In contrast, this work explored trust in a real-world setting. Method: Experienced rail operators in four signaling centers were observed for 90 min, and their activities were coded into five mutually exclusive categories. Their observed activities were analyzed in relation to their reported trust levels, collected via a questionnaire. Results: The results showed clear differences in activity, even when circumstances on the workstations were very similar, and significant differences in some trust dimensions were found between groups exhibiting different levels of intervention and time not involved with signaling. Conclusion: Although the empirical, lab-based studies in the literature have consistently found that reliability and competence of the automation are the most important aspects of trust development, understanding of the automation emerged as the strongest dimension in this study. The implications are that development and maintenance of trust in real-world, safety-critical automation systems may be distinct from artificial laboratory automation. Application: The findings have important implications for emerging automation concepts in diverse industries including highly automated vehicles and Internet of things. PMID:29613815
Suchsland, Juliane; Winter, Theresa; Greiser, Anne; Streichert, Thomas; Otto, Benjamin; Mayerle, Julia; Runge, Sören; Kallner, Anders; Nauck, Matthias; Petersmann, Astrid
2017-02-01
The innovative pneumatic tube system (iPTS) transports one sample at a time without the use of cartridges and allows rapid sending of samples directly into the bulk loader of a laboratory automation system (LAS). We investigated effects of the iPTS on samples and turn-around time (TAT). During transport, a mini data logger recorded the accelerations in three dimensions and reported them in arbitrary area under the curve (AUC) units. In addition representative quantities of clinical chemistry, hematology and coagulation were measured and compared in 20 blood sample pairs transported by iPTS and courier. Samples transported by iPTS were brought to the laboratory (300 m) within 30 s without adverse effects on the samples. The information retrieved from the data logger showed a median AUC of 7 and 310 arbitrary units for courier and iPTS transport, respectively. This is considerably below the reported limit for noticeable hemolysis of 500 arbitrary units. iPTS reduces TAT by reducing the hands-on time and a fast transport. No differences in the measurement results were found for any of the investigated 36 analytes between courier and iPTS transport. Based on these findings the iPTS was cleared for clinical use in our hospital.
Validation in the cytopathology laboratory: its time has come.
Haack, Lori A; Shalkham, John
2007-08-01
The cytology laboratory has traditionally performed a relatively small variety of tests. The testing processes employed were generally manually performed and included preparation of glass slide materials, staining of these slides, coverslipping, and microscopic evaluation of the cellular material. Instrumentation in the cytology laboratory was very limited and included a centrifuge, membrane filtration system, and possibly an automated staining machine. If instruments were added, for example, a liquid based preparation device or an automated coverslipping device; the instruments were rarely checked to assure they were operating properly before implementation into clinical practice. In addition, little documentation was maintained with regards to the instrument performance evaluation process. Increasing automation and expansion of testing options have changed how cytopathology is practiced. There are many new devices employed for the preparation of specimens, staining and coverslipping of slides, and evaluation of cellular material. The increasing use of molecular testing methods in cytopathology further adds to the changing landscape of cytopathology. New instrumentation and testing methods are routinely being introduced and the cytopathology laboratory must assure that the testing performed is accurate and consistent. Cytopathology laboratory professionals need to appreciate the value of validation of the tests we perform and the instruments we use in order to best serve the patient. Our clinical laboratory colleagues have traditionally performed validation on both instruments and test methods before using them for clinical testing. If cytopathology wants to perform the complex testing being introduced and effectively utilize new instrumentation, we need to understand the value of validation and how we apply validation to our laboratory practice. Copyright 2007 Wiley-Liss, Inc.
Impact of Automation on Drivers' Performance in Agricultural Semi-Autonomous Vehicles.
Bashiri, B; Mann, D D
2015-04-01
Drivers' inadequate mental workload has been reported as one of the negative effects of driving assistant systems and in-vehicle automation. The increasing trend of automation in agricultural vehicles raises some concerns about drivers' mental workload in such vehicles. Thus, a human factors perspective is needed to identify the consequences of such automated systems. In this simulator study, the effects of vehicle steering task automation (VSTA) and implement control and monitoring task automation (ICMTA) were investigated using a tractor-air seeder system as a case study. Two performance parameters (reaction time and accuracy of actions) were measured to assess drivers' perceived mental workload. Experiments were conducted using the tractor driving simulator (TDS) located in the Agricultural Ergonomics Laboratory at the University of Manitoba. Study participants were university students with tractor driving experience. According to the results, reaction time and number of errors made by drivers both decreased as the automation level increased. Correlations were found among performance parameters and subjective mental workload reported by the drivers.
International Nuclear Information System (INIS)
Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.
2004-01-01
An automated flow-based instrument for microwave-assisted treatment of liquid samples has been developed and characterized. The instrument utilizes a flow-through reaction vessel design that facilitates the addition of multiple reagents during sample treatment, removal of the gaseous reaction products, and enables quantitative removal of liquids from the reaction vessel for carryover-free operations. Matrix modification and speciation control chemistries that are required for the radiochemical determination of total 99Tc in caustic aged nuclear waste samples have been investigated. A rapid and quantitative oxidation procedure using peroxydisulfate in acidic solution was developed to convert reduced technetium species to pertechnetate in samples with high content of reducing organics. The effectiveness of the automated sample treatment procedures has been validated in the radiochemical analysis of total 99Tc in caustic aged nuclear waste matrixes from the Hanford site
Semi-Automated Processing of Trajectory Simulator Output Files for Model Evaluation
2018-01-01
ARL-TR-8284 ● JAN 2018 US Army Research Laboratory Semi-Automated Processing of Trajectory Simulator Output Files for Model...Semi-Automated Processing of Trajectory Simulator Output Files for Model Evaluation 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...although some minor changes may be needed. The program processes a GTRAJ output text file that contains results from 2 or more simulations , where each
Directory of Open Access Journals (Sweden)
Elena Ordoñez
2013-01-01
Full Text Available Objective. The detection of paternally inherited sequences in maternal plasma, such as the SRY gene for fetal sexing or RHD for fetal blood group genotyping, is becoming part of daily routine in diagnostic laboratories. Due to the low percentage of fetal DNA, it is crucial to ensure sample stability and the efficiency of DNA extraction. We evaluated blood stability at 4°C for at least 24 hours and automated DNA extraction, for fetal sex determination in maternal plasma. Methods. A total of 158 blood samples were collected, using EDTA-K tubes, from women in their 1st trimester of pregnancy. Samples were kept at 4°C for at least 24 hours before processing. An automated DNA extraction was evaluated, and its efficiency was compared with a standard manual procedure. The SRY marker was used to quantify cfDNA by real-time PCR. Results. Although lower cfDNA amounts were obtained by automated DNA extraction (mean 107,35 GE/mL versus 259,43 GE/mL, the SRY sequence was successfully detected in all 108 samples from pregnancies with male fetuses. Conclusion. We successfully evaluated the suitability of standard blood tubes for the collection of maternal blood and assessed samples to be suitable for analysis at least 24 hours later. This would allow shipping to a central reference laboratory almost from anywhere in Europe.
INITIATORS AND TRIGGERING CONDITIONS FOR ADAPTIVE AUTOMATION IN ADVANCED SMALL MODULAR REACTORS
Energy Technology Data Exchange (ETDEWEB)
Katya L Le Blanc; Johanna h Oxstrand
2014-04-01
It is anticipated that Advanced Small Modular Reactors (AdvSMRs) will employ high degrees of automation. High levels of automation can enhance system performance, but often at the cost of reduced human performance. Automation can lead to human out-of the loop issues, unbalanced workload, complacency, and other problems if it is not designed properly. Researchers have proposed adaptive automation (defined as dynamic or flexible allocation of functions) as a way to get the benefits of higher levels of automation without the human performance costs. Adaptive automation has the potential to balance operator workload and enhance operator situation awareness by allocating functions to the operators in a way that is sensitive to overall workload and capabilities at the time of operation. However, there still a number of questions regarding how to effectively design adaptive automation to achieve that potential. One of those questions is related to how to initiate (or trigger) a shift in automation in order to provide maximal sensitivity to operator needs without introducing undesirable consequences (such as unpredictable mode changes). Several triggering mechanisms for shifts in adaptive automation have been proposed including: operator initiated, critical events, performance-based, physiological measurement, model-based, and hybrid methods. As part of a larger project to develop design guidance for human-automation collaboration in AdvSMRs, researchers at Idaho National Laboratory have investigated the effectiveness and applicability of each of these triggering mechanisms in the context of AdvSMR. Researchers reviewed the empirical literature on adaptive automation and assessed each triggering mechanism based on the human-system performance consequences of employing that mechanism. Researchers also assessed the practicality and feasibility of using the mechanism in the context of an AdvSMR control room. Results indicate that there are tradeoffs associated with each
Site overview of robotics and automation
International Nuclear Information System (INIS)
Byrd, J.S.
1985-01-01
This paper summarizes the robotics and automation activities at the Savannah River Laboratory and the Savannah River Plant. The purpose is to provide an overview to facilitate the exchange of technology between various sites involved in development and production work for the Department of Energy. Throughout the paper references are made to assigned project engineers so that they may be contacted directly
Information systems as a quality management tool in clinical laboratories
Schmitz, Vanessa; Rosecler Bez el Boukhari, Marta
2007-11-01
This article describes information systems as a quality management tool in clinical laboratories. The quality of laboratory analyses is of fundamental importance for health professionals in aiding appropriate diagnosis and treatment. Information systems allow the automation of internal quality management processes, using standard sample tests, Levey-Jennings charts and Westgard multirule analysis. This simplifies evaluation and interpretation of quality tests and reduces the possibility of human error. This study proposes the development of an information system with appropriate functions and costs for the automation of internal quality control in small and medium-sized clinical laboratories. To this end, it evaluates the functions and usability of two commercial software products designed for this purpose, identifying the positive features of each, so that these can be taken into account during the development of the proposed system.
Information systems as a quality management tool in clinical laboratories
International Nuclear Information System (INIS)
Schmitz, Vanessa; Boukhari, Marta Rosecler Bez el
2007-01-01
This article describes information systems as a quality management tool in clinical laboratories. The quality of laboratory analyses is of fundamental importance for health professionals in aiding appropriate diagnosis and treatment. Information systems allow the automation of internal quality management processes, using standard sample tests, Levey-Jennings charts and Westgard multirule analysis. This simplifies evaluation and interpretation of quality tests and reduces the possibility of human error. This study proposes the development of an information system with appropriate functions and costs for the automation of internal quality control in small and medium-sized clinical laboratories. To this end, it evaluates the functions and usability of two commercial software products designed for this purpose, identifying the positive features of each, so that these can be taken into account during the development of the proposed system
Prakash, Bhaskaran David; Esuvaranathan, Kesavan; Ho, Paul C; Pasikanti, Kishore Kumar; Chan, Eric Chun Yong; Yap, Chun Wei
2013-05-21
A fully automated and computationally efficient Pearson's correlation change classification (APC3) approach is proposed and shown to have overall comparable performance with both an average accuracy and an average AUC of 0.89 ± 0.08 but is 3.9 to 7 times faster, easier to use and have low outlier susceptibility in contrast to other dimensional reduction and classification combinations using only the total ion chromatogram (TIC) intensities of GC/MS data. The use of only the TIC permits the possible application of APC3 to other metabonomic data such as LC/MS TICs or NMR spectra. A RapidMiner implementation is available for download at http://padel.nus.edu.sg/software/padelapc3.
Park, Yongjung; Park, Younhee; Joo, Shin Young; Park, Myoung Hee; Kim, Hyon-Suk
2011-11-01
We evaluated analytic performances of an automated treponemal test and compared this test with the Venereal Disease Research Laboratory test (VDRL) and fluorescent treponemal antibody absorption test (FTA-ABS). Precision performance of the Architect Syphilis TP assay (TP; Abbott Japan, Tokyo, Japan) was assessed, and 150 serum samples were assayed with the TP before and after heat inactivation to estimate the effect of heat inactivation. A total of 616 specimens were tested with the FTA-ABS and TP, and 400 were examined with the VDRL. The TP showed good precision performance with total imprecision of less than a 10% coefficient of variation. An excellent linear relationship between results before and after heat inactivation was observed (R(2) = 0.9961). The FTA-ABS and TP agreed well with a κ coefficient of 0.981. The concordance rate between the FTA-ABS and TP was the highest (99.0%), followed by the rates between FTA-ABS and VDRL (85.0%) and between TP and VDRL (83.8%). The automated TP assay may be adequate for screening for syphilis in a large volume of samples and can be an alternative to FTA-ABS.
Audit of the Reporting Requirements for Major Automated Information System Programs
National Research Council Canada - National Science Library
2000-01-01
.... There are 71 Major Automated Information System programs with total program costs of $26 billion. To qualify as a Major Automated Information System, the program must meet the following critena...
An Automated Motion Detection and Reward System for Animal Training.
Miller, Brad; Lim, Audrey N; Heidbreder, Arnold F; Black, Kevin J
2015-12-04
A variety of approaches has been used to minimize head movement during functional brain imaging studies in awake laboratory animals. Many laboratories expend substantial effort and time training animals to remain essentially motionless during such studies. We could not locate an "off-the-shelf" automated training system that suited our needs. We developed a time- and labor-saving automated system to train animals to hold still for extended periods of time. The system uses a personal computer and modest external hardware to provide stimulus cues, monitor movement using commercial video surveillance components, and dispense rewards. A custom computer program automatically increases the motionless duration required for rewards based on performance during the training session but allows changes during sessions. This system was used to train cynomolgus monkeys (Macaca fascicularis) for awake neuroimaging studies using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). The automated system saved the trainer substantial time, presented stimuli and rewards in a highly consistent manner, and automatically documented training sessions. We have limited data to prove the training system's success, drawn from the automated records during training sessions, but we believe others may find it useful. The system can be adapted to a range of behavioral training/recording activities for research or commercial applications, and the software is freely available for non-commercial use.
Automated atomic absorption spectrophotometer, utilizing a programmable desk calculator
International Nuclear Information System (INIS)
Futrell, T.L.; Morrow, R.W.
1977-01-01
A commercial, double-beam atomic absorption spectrophotometer has been interfaced with a sample changer and a Hewlett-Packard 9810A calculator to yield a completely automated analysis system. The interface electronics can be easily constructed and should be adaptable to any double-beam atomic absorption instrument. The calculator is easily programmed and can be used for general laboratory purposes when not operating the instrument. The automated system has been shown to perform very satisfactorily when operated unattended to analyze a large number of samples. Performance statistics agree well with a manually operated instrument
Bar-code automated waste tracking system
International Nuclear Information System (INIS)
Hull, T.E.
1994-10-01
The Bar-Code Automated Waste Tracking System was designed to be a site-Specific program with a general purpose application for transportability to other facilities. The system is user-friendly, totally automated, and incorporates the use of a drive-up window that is close to the areas dealing in container preparation, delivery, pickup, and disposal. The system features ''stop-and-go'' operation rather than a long, tedious, error-prone manual entry. The system is designed for automation but allows operators to concentrate on proper handling of waste while maintaining manual entry of data as a backup. A large wall plaque filled with bar-code labels is used to input specific details about any movement of waste
Automated Installation Verification of COMSOL via LiveLink for MATLAB
International Nuclear Information System (INIS)
Crowell, Michael W
2015-01-01
Verifying that a local software installation performs as the developer intends is a potentially time-consuming but necessary step for nuclear safety-related codes. Automating this process not only saves time, but can increase reliability and scope of verification compared to ''hand'' comparisons. While COMSOL does not include automatic installation verification as many commercial codes do, it does provide tools such as LiveLink"T"M for MATLAB® and the COMSOL API for use with Java® through which the user can automate the process. Here we present a successful automated verification example of a local COMSOL 5.0 installation for nuclear safety-related calculations at the Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR).
Efficiency of an automated reception and turnaround time management system for the phlebotomy room.
Yun, Soon Gyu; Shin, Jeong Won; Park, Eun Su; Bang, Hae In; Kang, Jung Gu
2016-01-01
Recent advances in laboratory information systems have largely been focused on automation. However, the phlebotomy services have not been completely automated. To address this issue, we introduced an automated reception and turnaround time (TAT) management system, for the first time in Korea, whereby the patient's information is transmitted directly to the actual phlebotomy site and the TAT for each phlebotomy step can be monitored at a glance. The GNT5 system (Energium Co., Ltd., Korea) was installed in June 2013. The automated reception and TAT management system has been in operation since February 2014. Integration of the automated reception machine with the GNT5 allowed for direct transmission of laboratory order information to the GNT5 without involving any manual reception step. We used the mean TAT from reception to actual phlebotomy as the parameter for evaluating the efficiency of our system. Mean TAT decreased from 5:45 min to 2:42 min after operationalization of the system. The mean number of patients in queue decreased from 2.9 to 1.0. Further, the number of cases taking more than five minutes from reception to phlebotomy, defined as the defect rate, decreased from 20.1% to 9.7%. The use of automated reception and TAT management system was associated with a decrease of overall TAT and an improved workflow at the phlebotomy room.
Automated micro fluidic system for PCR applications in the monitoring of drinking water quality
International Nuclear Information System (INIS)
Soria Soria, E.; Yanez Amoros, A.; Murtula Corbi, R.; Catalan Cuenca, V.; Martin-Cisneros, C. S.; Ymbern, O.; Alonso-Chamorro, J.
2009-01-01
Microbiological laboratories present a growing interest in automated, simple and user-friendly methodologies able to perform simultaneous analysis of a high amount of samples. Analytical tools based on micro-fluidic could play an important role in this field. In this work, the development of an automated micro fluidic system for PCR applications and aimed to monitoring of drinking water quality is presented. The device will be able to determine, simultaneously, fecal pollution indicators and water-transmitted pathogens. Further-more, complemented with DNA pre-concentration and extraction modules, the device would present a highly integrated solution for microbiological diagnostic laboratories. (Author) 13 refs.
SHARP - Automated monitoring of spacecraft health and status
Atkinson, David J.; James, Mark L.; Martin, R. G.
1990-01-01
Briefly discussed here are the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory (JPL). Some of the difficulties associated with the existing technology used in mission operations are highlighted. A new automated system based on artificial intelligence technology is described which seeks to overcome many of these limitations. The system, called the Spacecraft Health Automated Reasoning Prototype (SHARP), is designed to automate health and status analysis for multi-mission spacecraft and ground data systems operations. The system has proved to be effective for detecting and analyzing potential spacecraft and ground systems problems by performing real-time analysis of spacecraft and ground data systems engineering telemetry. Telecommunications link analysis of the Voyager 2 spacecraft was the initial focus for evaluation of the system in real-time operations during the Voyager spacecraft encounter with Neptune in August 1989.
SHARP: Automated monitoring of spacecraft health and status
Atkinson, David J.; James, Mark L.; Martin, R. Gaius
1991-01-01
Briefly discussed here are the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory (JPL). Some of the difficulties associated with the existing technology used in mission operations are highlighted. A new automated system based on artificial intelligence technology is described which seeks to overcome many of these limitations. The system, called the Spacecraft Health Automated Reasoning Prototype (SHARP), is designed to automate health and status analysis for multi-mission spacecraft and ground data systems operations. The system has proved to be effective for detecting and analyzing potential spacecraft and ground systems problems by performing real-time analysis of spacecraft and ground data systems engineering telemetry. Telecommunications link analysis of the Voyager 2 spacecraft was the initial focus for evaluation of the system in real-time operations during the Voyager spacecraft encounter with Neptune in August 1989.
Automated particulate sampler field test model operations guide
Energy Technology Data Exchange (ETDEWEB)
Bowyer, S.M.; Miley, H.S.
1996-10-01
The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.
A simple method for validation and verification of pipettes mounted on automated liquid handlers
DEFF Research Database (Denmark)
Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg
We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...
Errors in clinical laboratories or errors in laboratory medicine?
Plebani, Mario
2006-01-01
Laboratory testing is a highly complex process and, although laboratory services are relatively safe, they are not as safe as they could or should be. Clinical laboratories have long focused their attention on quality control methods and quality assessment programs dealing with analytical aspects of testing. However, a growing body of evidence accumulated in recent decades demonstrates that quality in clinical laboratories cannot be assured by merely focusing on purely analytical aspects. The more recent surveys on errors in laboratory medicine conclude that in the delivery of laboratory testing, mistakes occur more frequently before (pre-analytical) and after (post-analytical) the test has been performed. Most errors are due to pre-analytical factors (46-68.2% of total errors), while a high error rate (18.5-47% of total errors) has also been found in the post-analytical phase. Errors due to analytical problems have been significantly reduced over time, but there is evidence that, particularly for immunoassays, interference may have a serious impact on patients. A description of the most frequent and risky pre-, intra- and post-analytical errors and advice on practical steps for measuring and reducing the risk of errors is therefore given in the present paper. Many mistakes in the Total Testing Process are called "laboratory errors", although these may be due to poor communication, action taken by others involved in the testing process (e.g., physicians, nurses and phlebotomists), or poorly designed processes, all of which are beyond the laboratory's control. Likewise, there is evidence that laboratory information is only partially utilized. A recent document from the International Organization for Standardization (ISO) recommends a new, broader definition of the term "laboratory error" and a classification of errors according to different criteria. In a modern approach to total quality, centered on patients' needs and satisfaction, the risk of errors and mistakes
Sensors and Automated Analyzers for Radionuclides
International Nuclear Information System (INIS)
Grate, Jay W.; Egorov, Oleg B.
2003-01-01
The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less
Automated biosurveillance data from England and Wales, 1991-2011.
Enki, Doyo G; Noufaily, Angela; Garthwaite, Paul H; Andrews, Nick J; Charlett, André; Lane, Chris; Farrington, C Paddy
2013-01-01
Outbreak detection systems for use with very large multiple surveillance databases must be suited both to the data available and to the requirements of full automation. To inform the development of more effective outbreak detection algorithms, we analyzed 20 years of data (1991-2011) from a large laboratory surveillance database used for outbreak detection in England and Wales. The data relate to 3,303 distinct types of infectious pathogens, with a frequency range spanning 6 orders of magnitude. Several hundred organism types were reported each week. We describe the diversity of seasonal patterns, trends, artifacts, and extra-Poisson variability to which an effective multiple laboratory-based outbreak detection system must adjust. We provide empirical information to guide the selection of simple statistical models for automated surveillance of multiple organisms, in the light of the key requirements of such outbreak detection systems, namely, robustness, flexibility, and sensitivity.
Directory of Open Access Journals (Sweden)
Joshua J.H. Hunsaker
2016-12-01
Full Text Available Objectives: Refractometric methods to measure total protein (TP in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Design and methods: Performance evaluation of a MISCO Palm Abbe⢠digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Results: Carryover risk was eliminated using a demineralized distilled water (ddH2O wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool and 0.5% CV (high TP pool. Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0% was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a low and high concentration patient pools, or b albumin-spiked ddH2O and high concentration patient pool. Decreased recovery was observed using ddH2O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL and triglycerides (>580 mg/dL. Current laboratory reference intervals for TP were verified. Conclusions: Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses. Keywords: Refractometry, Digital refractometry, Total protein, Biuret, Serum protein electrophoresis, Monoclonal
Energy Technology Data Exchange (ETDEWEB)
Bostick, Debra A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hexel, Cole R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ticknor, Brian W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tevepaugh, Kayron N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Metzger, Shalina C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
2016-11-01
To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs
The University of New Mexico/Sandia National Laboratories small-angle scattering laboratory
International Nuclear Information System (INIS)
Rieker, T.P.; Hubbard, P.F.
1998-01-01
The University of New Mexico/Sandia National Laboratories small-angle scattering laboratory provides a wide q-range, 3x10 -4 Angstrom -1 -1 , for the structural analysis of materials on length scales from a few angstrom to ∼0.1 μm. The wide q-range is accomplished by combining data from a Bonse-Hart spectrometer (3x10 -4 Angstrom -1 -2 Angstrom -1 ) and a 5 m pinhole (3x10 -3 Angstrom -1 -1 ) instrument. Automation of the data acquisition systems along with a variety of sample environments and sample changers yields flexible, high throughput instruments. copyright 1998 American Institute of Physics
International Nuclear Information System (INIS)
Acosta, Andy L. Romero; Lores, Stefan Gutierrez
2013-01-01
This paper presents the design and implementation of an automated system for measurements in the calibration of reference radiation dosimeters. It was made a software application that performs the acquisition of the measured values of electric charge, calculated calibration coefficient and automates the calibration certificate issuance. These values are stored in a log file on a PC. The use of the application improves control over the calibration process, helps to humanize the work and reduces personnel exposure. The tool developed has been applied to the calibration of dosimeters radiation patterns in the LSCD of the Centro de Proteccion e Higiene de las Radiaciones, Cuba
International Nuclear Information System (INIS)
Nestler, J.; Richardson, P.I.
1988-01-01
Various papers on the automated testing of electrooptical systems are presented. Individual topics addressed include: simultaneous automated testing of Thematic Mapper dynamic spatial performance characteristics, results of objective automatic minimum resolvable temperature testing of thermal imagers using a proposed new figure of merit, test and manufacture of three-mirror laboratory telescope, calculation of apparent delta-T errors for band-limited detectors, and automated laser seeker performance evaluation system
Advanced digital computers, controls, and automation technologies for power plants: Proceedings
International Nuclear Information System (INIS)
Bhatt, S.C.
1992-08-01
This document is a compilation of the papers that were presented at an EPRI workshop on Advances in Computers, Controls, and Automation Technologies for Power Plants. The workshop, sponsored by EPRI's Nuclear Power Division, took place February 1992. It was attended by 157 representatives from electric utilities, equipment manufacturers, engineering consulting organizations, universities, national laboratories, government agencies and international utilities. More than 40% of the attendees were from utilities representing the majority group. There were 30% attendees from equipment manufacturers and the engineering consulting organizations. The participants from government agencies, universities, and national laboratories were about 10% each. The workshop included a keynote address, 35 technical papers, and vendor's equipment demonstrations. The technical papers described the state-of-the-art in the areas of recent utility digital upgrades such as digital feedwater controllers, steam generator level controllers, integrated plant computer systems, computer aided diagnostics, automated testing and surveillance and other applications. A group of technical papers presented the ongoing B ampersand W PWR integrated plant control system prototype developments with the triple redundant advanced digital control system. Several international papers from France, Japan and U.K. presented their programs on advance power plant design and applications. Significant advances in the control and automation technologies such as adaptive controls, self-tuning methods, neural networks and expert systems were presented by developers, universities, and national laboratories. Individual papers are indexed separately
International Nuclear Information System (INIS)
Martinez, B.; Montoya, A.; Klein, W.
1999-01-01
The waste management and environmental compliance group (NMT-7) at the Los Alamos National Laboratory has initiated a pilot project for demonstrating the feasibility and utility of automated data collection as a solution for tracking waste containers at the Los Alamos National Laboratory Plutonium Facility. This project, the Los Alamos Waste Tracking System (LAWTS), tracks waste containers during their lifecycle at the facility. LAWTS is a two-tiered system consisting of a server/workstation database and reporting engine and a hand-held data terminal-based client program for collecting data directly from tracked containers. New containers may be added to the system from either the client unit or from the server database. Once containers are in the system, they can be tracked through one of three primary transactions: Move, Inventory, and Shipment. Because LAWTS is a pilot project, it also serves as a learning experience for all parties involved. This paper will discuss many of the lessons learned in implementing a data collection system in the restricted environment. Specifically, the authors will discuss issues related to working with the PPT 4640 terminal system as the data collection unit. They will discuss problems with form factor (size, usability, etc.) as well as technical problems with wireless radio frequency functions. They will also discuss complications that arose from outdoor use of the terminal (barcode scanning failures, screen readability problems). The paper will conclude with a series of recommendations for proceeding with LAWTS based on experience to date
Test Results for the Automated Rendezvous and Capture System
Cruzen, Craig; Dabney, Richard; Lomas, James
1999-01-01
The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.
Teaching Electronics and Laboratory Automation Using Microcontroller Boards
Mabbott, Gary A.
2014-01-01
Modern microcontroller boards offer the analytical chemist a powerful and inexpensive means of interfacing computers and laboratory equipment. The availability of a host of educational materials, compatible sensors, and electromechanical devices make learning to implement microcontrollers fun and empowering. This article describes the advantages…
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Open Automated Demand Response Communications Specification (Version 1.0)
Energy Technology Data Exchange (ETDEWEB)
Piette, Mary Ann; Ghatikar, Girish; Kiliccote, Sila; Koch, Ed; Hennage, Dan; Palensky, Peter; McParland, Charles
2009-02-28
The development of the Open Automated Demand Response Communications Specification, also known as OpenADR or Open Auto-DR, began in 2002 following the California electricity crisis. The work has been carried out by the Demand Response Research Center (DRRC), which is managed by Lawrence Berkeley National Laboratory. This specification describes an open standards-based communications data model designed to facilitate sending and receiving demand response price and reliability signals from a utility or Independent System Operator to electric customers. OpenADR is one element of the Smart Grid information and communications technologies that are being developed to improve optimization between electric supply and demand. The intention of the open automated demand response communications data model is to provide interoperable signals to building and industrial control systems that are preprogrammed to take action based on a demand response signal, enabling a demand response event to be fully automated, with no manual intervention. The OpenADR specification is a flexible infrastructure to facilitate common information exchange between the utility or Independent System Operator and end-use participants. The concept of an open specification is intended to allow anyone to implement the signaling systems, the automation server or the automation clients.
Choi, Jonghyeon; Park, Yongjung; Kim, Jeong-Ho; Kim, Hyon-Suk
2011-12-01
We evaluated two new autoanalyzers, μTAS and Lumipulse for des-γ-carboxyprothrombin (DCP) assay. Analytical performance was evaluated, and the upper reference limit of the 97.5th percentile for DCP was re-established using sera from 140 healthy individuals. DCP levels were determined by the two autoanalyzers and EIA in a total of 239 sera from HCC patients (n=120) and those without HCC (n=119). Total imprecision of the two automated assays was Lumipulse. There were proportional and constant biases between the results from the autoanalyzers and those from EIA. The two newly developed DCP assays showed high analytical performance, but re-establishment of reference limits would be necessary. The new analyzers could be useful for clinical laboratories because of convenience of operation and wide AMRs. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Performance indicators and decision making for outsourcing public health laboratory services.
Santos, Maria Angelica Borges dos; Moraes, Ricardo Montes de; Passos, Sonia Regina Lambert
2012-06-01
To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network
Egorov, Oleg B; O'Hara, Matthew J; Grate, Jay W
2012-04-03
An automated fluidic instrument is described that rapidly determines the total (99)Tc content of aged nuclear waste samples, where the matrix is chemically and radiologically complex and the existing speciation of the (99)Tc is variable. The monitor links microwave-assisted sample preparation with an automated anion exchange column separation and detection using a flow-through solid scintillator detector. The sample preparation steps acidify the sample, decompose organics, and convert all Tc species to the pertechnetate anion. The column-based anion exchange procedure separates the pertechnetate from the complex sample matrix, so that radiometric detection can provide accurate measurement of (99)Tc. We developed a preprogrammed spike addition procedure to automatically determine matrix-matched calibration. The overall measurement efficiency that is determined simultaneously provides a self-diagnostic parameter for the radiochemical separation and overall instrument function. Continuous, automated operation was demonstrated over the course of 54 h, which resulted in the analysis of 215 samples plus 54 hly spike-addition samples, with consistent overall measurement efficiency for the operation of the monitor. A sample can be processed and measured automatically in just 12.5 min with a detection limit of 23.5 Bq/mL of (99)Tc in low activity waste (0.495 mL sample volume), with better than 10% RSD precision at concentrations above the quantification limit. This rapid automated analysis method was developed to support nuclear waste processing operations planned for the Hanford nuclear site.
International Nuclear Information System (INIS)
Battersby, C.; Dickson, R.; Jennings, R.; Kimmons, J.; Kozlowski, M. R.; Maricle, S.; Mouser, R.; Runkel, M.; Schwartz, S.; Sheehan, L. M.; Weinzapfel, C.
1998-01-01
The Laser Program at LLNL has developed automated facilities for damage testing optics up to 1 meter in diameter. The systems were developed to characterize the statistical distribution of localized damage performance across large-aperture National Ignition Facility optics. Full aperture testing is a key component of the quality assurance program for several of the optical components. The primary damage testing methods used are R:1 mapping and raster scanning. Automation of these test methods was required to meet the optics manufacturing schedule. The automated activities include control and diagnosis of the damage-test laser beam as well as detection and characterization of damage events
Patton, Charles J.; Truitt, Earl P.
1992-01-01
A method to determine total phosphorus (TP) in the same digests prepared for total Kjeldahl nitrogen (TKN) determinations is desribed. The batch, high-temperature (block digester), HG(II)-catalyzed digestion step is similar to U.S. Geological Survey methods I-2552-85/I-4552-85 and U.S. Environmental Protection Agency method 365.4 except that sample and reagent volumes are halved. Prepared digests are desolvated at 220 degrees Celsius and digested at 370 degrees Celsius in separate block digesters set at these temperatures, rather than in a single, temperature-programmed block digester. This approach is used in the method escribed here, which permits 40 calibrants, reference waters, and smaples to be digested and resolvated in about an hour. Orthophosphate ions originally present in samples, along with those released during the digestion step, are determined colorimetrically at a rate of 90 tests per hour by an automated version of the phosphoantimonylmolybdenum blue procedure. About 100 microliters of digest are required per determination. The upper concentration limit is 2 milligrams per liter (mg/L) with a method detection limt of 0.01 mg/L. Repeatability for a sample containing approximately 1.6 mg/L of TP in a high suspended-solids matrix is 0.7 percent. Between-day precision for the same sample is 5.0 percent. A dialyzer in the air-segmented continuous flow analyzer provides on-line digest cleanup, eliminated particulates that otherwise would interfere in the colorimetric finish. An single-channel analyzer can process the resolvated digests from two pairs of block digesters each hour. Paired t-test analysis of TP concentrations for approximately 1,600 samples determined by the new method (U.S. Geologial Survey methods I-2610-91 and I-4610-91) and the old method (U.S. Geological Survey methods I-2600-85 and I-4600-85) revealed positive bias in the former of 0.02 to 0.04 mg/L for surface-water samples in agreement with previous studies. Concentrations of total
Flexible automated approach for quantitative liquid handling of complex biological samples.
Palandra, Joe; Weller, David; Hudson, Gary; Li, Jeff; Osgood, Sarah; Hudson, Emily; Zhong, Min; Buchholz, Lisa; Cohen, Lucinda H
2007-11-01
A fully automated protein precipitation technique for biological sample preparation has been developed for the quantitation of drugs in various biological matrixes. All liquid handling during sample preparation was automated using a Hamilton MicroLab Star Robotic workstation, which included the preparation of standards and controls from a Watson laboratory information management system generated work list, shaking of 96-well plates, and vacuum application. Processing time is less than 30 s per sample or approximately 45 min per 96-well plate, which is then immediately ready for injection onto an LC-MS/MS system. An overview of the process workflow is discussed, including the software development. Validation data are also provided, including specific liquid class data as well as comparative data of automated vs manual preparation using both quality controls and actual sample data. The efficiencies gained from this automated approach are described.
Robotic and nuclear safety for an automated/teleoperated glove box system
International Nuclear Information System (INIS)
Domning, E.E.; McMahon, T.T.; Sievers, R.H.
1991-09-01
Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system to handle the processing of special nuclear materials (SNM). This work is performed in response to the new goals at the Department of Energy (DOE) for hazardous waste minimization and radiation dose reduction. This fully automated system, called the automated test bed (ATB), consists of an IBM gantry robot and automated processing equipment sealed within a glove box. While the ATB is a cold system, we are designing it as a prototype of the future hot system. We recognized that identification and application of safety requirements early in the design phase will lead to timely installation and approval of the hot system. This paper identifies these safety issues as well as the general safety requirements necessary for the safe operation of the ATB. 4 refs., 2 figs
The evolution of automation and robotics in manned spaceflight
Moser, T. L.; Erickson, J. D.
1986-01-01
The evolution of automation on all manned spacecraft including the Space Shuttle is reviewed, and a concept for increasing automation and robotics from the current Shuttle Remote Manipulator System (RMS) to an autonomous system is presented. The requirements for robotic elements are identified for various functions on the Space Station, including extravehicular functions and functions within laboratory and habitation modules which expand man's capacity in space and allow selected teleoperation from the ground. The initial Space Station will employ a telerobot and necessary knowledge based systems as an advisory to the crew on monitoring, fault diagnosis, and short term planning and scheduling.
Fei, Yang; Kang, Fengfeng; Wang, Wei; Zhao, Haijian; He, Falin; Zhong, Kun; Wang, Zhiguo; Chen, Wenxiang
2016-08-01
The aim of the study was to promote the establishment and implementation of quality indicators (QIs) in clinical laboratories, catch up with the state of art, and provide preliminary quality specifications for established QIs. Clinical laboratories from different provinces in China were included in this QIs survey in 2015. All participants were asked to collect data related to QIs and complete QIs questionnaires. Defect percentages and sigma values were calculated for each QI. The 25th percentile, median, and the 75th percentile of defect percentages and TATs were calculated as optimum, desirable and minimum quality specifications. While 25th, median, and 75th of sigma values were calculated as minimum, desirable and optimum quality specifications, respectively. Five thousand seven hundred and fifty-three clinical laboratories from 28 provinces in China participated in this survey. Median defect percentages of pre-examination QIs varied largely from 0.01% (incorrect sample container) to 0.57% (blood culture contamination) with sigma values varied from 4.0σ to 5.1σ. Median defect percentages of examination phase QIs were all really high. The most common problem in examination phase was test uncovered by inter-laboratory comparison (86.67%). Defect percentages of critical values notification and timely critical values notification were all 0.00% (6.0σ). While the median of defect percentages of incorrect laboratory reports was only 0.01% (5.4σ). Improvements are needed in all phases of total testing process (TTP) in laboratories in China, especially in examination phase. More attention should be paid when microbiology specimens are collected and results are reported. Quality specifications can provide directions for laboratories to make effort for.
Expected Improvements in Work Truck Efficiency Through Connectivity and Automation
Energy Technology Data Exchange (ETDEWEB)
Walkowicz, Kevin A [National Renewable Energy Laboratory (NREL), Golden, CO (United States)
2018-03-12
This presentation focuses on the potential impact of connected and automated technologies on commercial vehicle operations. It includes topics such as the U.S. Department of Energy's Energy Efficient Mobility Systems (EEMS) program and the Systems and Modeling for Accelerated Research in Transportation (SMART) Mobility Initiative. It also describes National Renewable Energy Laboratory (NREL) research findings pertaining to the potential energy impacts of connectivity and automation and stresses the need for integration and optimization to take advantage of the benefits offered by these transformative technologies while mitigating the potential negative consequences.
A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.
Robitaille, Line; Hoffer, L John
2016-04-21
In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.
Development of a robotics system for automated chemical analysis of sediments, sludges, and soils
International Nuclear Information System (INIS)
McGrail, B.P.; Dodson, M.G.; Skorpik, J.R.; Strachan, D.M.; Barich, J.J.
1989-01-01
Adaptation and use of a high-reliability robot to conduct a standard laboratory procedure for soil chemical analysis are reported. Results from a blind comparative test were used to obtain a quantitative measure of the improvement in precision possible with the automated test method. Results from the automated chemical analysis procedure were compared with values obtained from an EPA-certified lab and with results from a more extensive interlaboratory round robin conducted by the EPA. For several elements, up to fivefold improvement in precision was obtained with the automated test method
Hormann, Wymke; Hahn, Melanie; Gerlach, Stefan; Hochstrate, Nicola; Affeldt, Kai; Giesen, Joyce; Fechner, Kai; Damoiseaux, Jan G M C
2017-11-27
Antibodies directed against dsDNA are a highly specific diagnostic marker for the presence of systemic lupus erythematosus and of particular importance in its diagnosis. To assess anti-dsDNA antibodies, the Crithidia luciliae-based indirect immunofluorescence test (CLIFT) is one of the assays considered to be the best choice. To overcome the drawback of subjective result interpretation that inheres indirect immunofluorescence assays in general, automated systems have been introduced into the market during the last years. Among these systems is the EUROPattern Suite, an advanced automated fluorescence microscope equipped with different software packages, capable of automated pattern interpretation and result suggestion for ANA, ANCA and CLIFT analysis. We analyzed the performance of the EUROPattern Suite with its automated fluorescence interpretation for CLIFT in a routine setting, reflecting the everyday life of a diagnostic laboratory. Three hundred and twelve consecutive samples were collected, sent to the Central Diagnostic Laboratory of the Maastricht University Medical Centre with a request for anti-dsDNA analysis over a period of 7 months. Agreement between EUROPattern assay analysis and the visual read was 93.3%. Sensitivity and specificity were 94.1% and 93.2%, respectively. The EUROPattern Suite performed reliably and greatly supported result interpretation. Automated image acquisition is readily performed and automated image classification gives a reliable recommendation for assay evaluation to the operator. The EUROPattern Suite optimizes workflow and contributes to standardization between different operators or laboratories.
Automation surprise : results of a field survey of Dutch pilots
de Boer, R.J.; Hurts, Karel
2017-01-01
Automation surprise (AS) has often been associated with aviation safety incidents. Although numerous laboratory studies have been conducted, few data are available from routine flight operations. A survey among a representative sample of 200 Dutch airline pilots was used to determine the prevalence
Altering user' acceptance of automation through prior automation exposure.
Bekier, Marek; Molesworth, Brett R C
2017-06-01
Air navigation service providers worldwide see increased use of automation as one solution to overcome the capacity constraints imbedded in the present air traffic management (ATM) system. However, increased use of automation within any system is dependent on user acceptance. The present research sought to determine if the point at which an individual is no longer willing to accept or cooperate with automation can be manipulated. Forty participants underwent training on a computer-based air traffic control programme, followed by two ATM exercises (order counterbalanced), one with and one without the aid of automation. Results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation ('tipping point') decreased; suggesting it is indeed possible to alter automation acceptance. Practitioner Summary: This paper investigates whether the point at which a user of automation rejects automation (i.e. 'tipping point') is constant or can be manipulated. The results revealed after exposure to a task with automation assistance, user acceptance of high(er) levels of automation decreased; suggesting it is possible to alter automation acceptance.
Energy Technology Data Exchange (ETDEWEB)
Ulsh, M.; Wheeler, D.; Protopappas, P.
2011-08-01
The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that the National Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level of vertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, and the relationship between production volume and decisions on automation.
Automated reasoning in man-machine control systems
International Nuclear Information System (INIS)
Stratton, R.C.; Lusk, E.L.
1983-01-01
This paper describes a project being undertaken at Argonne National Laboratory to demonstrate the usefulness of automated reasoning techniques in the implementation of a man-machine control system being designed at the EBR-II nuclear power plant. It is shown how automated reasoning influences the choice of optimal roles for both man and machine in the system control process, both for normal and off-normal operation. In addition, the requirements imposed by such a system for a rigorously formal specification of operating states, subsystem states, and transition procedures have a useful impact on the analysis phase. The definitions and rules are discussed for a prototype system which is physically simple yet illustrates some of the complexities inherent in real systems
Laboratory Information Management System Chain of Custody: Reliability and Security
Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.
2006-01-01
A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of a...
Directory of Open Access Journals (Sweden)
Zhan Shu
2011-07-01
Full Text Available Abstract We recently demonstrated the utility of quantifying spontaneous pain in mice via the blinded coding of facial expressions. As the majority of preclinical pain research is in fact performed in the laboratory rat, we attempted to modify the scale for use in this species. We present herein the Rat Grimace Scale, and show its reliability, accuracy, and ability to quantify the time course of spontaneous pain in the intraplantar complete Freund's adjuvant, intraarticular kaolin-carrageenan, and laparotomy (post-operative pain assays. The scale's ability to demonstrate the dose-dependent analgesic efficacy of morphine is also shown. In addition, we have developed software, Rodent Face Finder®, which successfully automates the most labor-intensive step in the process. Given the known mechanistic dissociations between spontaneous and evoked pain, and the primacy of the former as a clinical problem, we believe that widespread adoption of spontaneous pain measures such as the Rat Grimace Scale might lead to more successful translation of basic science findings into clinical application.
Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.
Alagrund, Katariina; Orpana, Arto K
2014-01-01
The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.
International Nuclear Information System (INIS)
Petro Zoriy; Reinhold Flucht; Mechthild Burow; Peter Ostapczuk; Reinhard Lennartz; Myroslav Zoriy
2010-01-01
A robust analytical method has been developed in our laboratory for the separation of radionuclides by means of extraction chromatography using an automated separation system. The proposed method is both cheap and simple and provides the advantageous, rapid and accurate separation of the element of interest. The automated separation system enables a shorter separation time by maintaining a constant flow rate of solution and by avoiding clogging or bubbling in the chromatographic column. The present separation method was tested with two types of samples (water and urine) using UTEVA-, TRU- and Sr-specific resins for the separation of U, Th, Am, Pu and Sr. The total separation time for one radionuclide ranged from 60 to 100 min with the separation yield ranging from 68 to 98% depending on the elements separated. We used ICP-QMS, multi-low-level counter and alpha spectroscopy to measure the corresponding elements. (author)
AUTOMATION FOR THE SYNTHESIS AND APPLICATION OF PET RADIOPHARMACEUTICALS
International Nuclear Information System (INIS)
Alexoff, D.L.
2001-01-01
The development of automated systems supporting the production and application of PET radiopharmaceuticals has been an important focus of researchers since the first successes of using carbon-11 (Comar et al., 1979) and fluorine-18 (Reivich et al., 1979) labeled compounds to visualize functional activity of the human brain. These initial successes of imaging the human brain soon led to applications in the human heart (Schelbert et al., 1980), and quickly radiochemists began to see the importance of automation to support PET studies in humans (Lambrecht, 1982; Langstrom et al., 1983). Driven by the necessity of controlling processes emanating high fluxes of 511 KeV photons, and by the tedium of repetitive syntheses for carrying out these human PET investigations, academic and government scientists have designed, developed and tested many useful and novel automated systems in the past twenty years. These systems, originally designed primarily by radiochemists, not only carry out effectively the tasks they were designed for, but also demonstrate significant engineering innovation in the field of laboratory automation
Directory of Open Access Journals (Sweden)
Guy Schwartz
2012-01-01
Full Text Available The commonly used analytic method for assessing total petroleum hydrocarbons (TPH in soil, EPA method 418.1, is usually based on extraction with 1,1,2-trichlorotrifluoroethane (Freon 113 and FTIR spectroscopy of the extracted solvent. This method is widely used for initial site investigation, due to the relative low price per sample. It is known that the extraction efficiency varies depending on the extracting solvent and other sample properties. This study’s main goal was to evaluate reflectance spectroscopy as a tool for TPH assessment, as compared with three commercial certified laboratories using traditional methods. Large variations were found between the results of the three commercial laboratories, both internally (average deviation up to 20%, and between laboratories (average deviation up to 103%. Reflectance spectroscopy method was found be as good as the commercial laboratories in terms of accuracy and could be a viable field-screening tool that is rapid, environmental friendly, and cost effective.
National SCADA Test Bed Substation Automation Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Kenneth Barnes; Briam Johnson
2009-10-01
Increased awareness of the potential for cyber attack has recently resulted in improved cyber security practices associated with the electrical power grid. However, the level of practical understanding and deployment of cyber security practices has not been evenly applied across all business sectors. Much of the focus has been centered on information technology business centers and control rooms. This report explores the current level of substation automation, communication, and cyber security protection deployed in electrical substations throughout existing utilities in the United States. This report documents the evaluation of substation automation implementation and associated vulnerabilities. This evaluation used research conducted by Newton-Evans Research Company for some of its observations and results. The Newton Evans Report aided in the determination of what is the state of substation automation in North American electric utilities. Idaho National Laboratory cyber security experts aided in the determination of what cyber vulnerabilities may pose a threat to electrical substations. This report includes cyber vulnerabilities as well as recommended mitigations. It also describes specific cyber issues found in typical substation automation configurations within the electric utility industry. The evaluation report was performed over a 5-month period starting in October 2008
Automation of the Calibration of Reference Dosimeters Used in Radiotherapy
International Nuclear Information System (INIS)
Romero Acosta, A.; Gutierrez Lores, S.
2013-01-01
Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. The role of Secondary Standard Dosimetry Laboratories (SSDLs) is crucial in providing traceable calibrations to hospitals, since these laboratories disseminate calibrations at specific radiation qualities appropriate to the use of radiation measuring instruments. These laboratories follow IAEA/WHO guidelines for calibration procedures, often being current and charge measurements described in these guidelines a tedious task. However, these measurements are usually done using modern electrometers which are equipped with a RS-232 interface that allows instrument control from a PC. This paper presents the design and employment of an automated system aimed to the measurements of the radiotherapy dosimeters calibration process for Cobalt-60 gamma rays. A software was developed using Lab View, in order to achieve the acquisition of the charge values measured, calculation of the calibration coefficient and issue of a calibration certificate. A primary data report file is filled and stored in the PC's hard disk. By using this software tool, a better control over the calibration process is achieved, it reduces the need for human intervention and it also reduces the exposure of the laboratory staff. The automated system has been used for the calibration of reference dosimeters used in radiotherapy at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene (Author)
Amendola, Alessandra; Coen, Sabrina; Belladonna, Stefano; Pulvirenti, F Renato; Clemens, John M; Capobianchi, M Rosaria
2011-08-01
Diagnostic laboratories need automation that facilitates efficient processing and workflow management to meet today's challenges for expanding services and reducing cost, yet maintaining the highest levels of quality. Processing efficiency of two commercially available automated systems for quantifying HIV-1 and HCV RNA, Abbott m2000 system and Roche COBAS Ampliprep/COBAS TaqMan 96 (docked) systems (CAP/CTM), was evaluated in a mid/high throughput workflow laboratory using a representative daily workload of 24 HCV and 72 HIV samples. Three test scenarios were evaluated: A) one run with four batches on the CAP/CTM system, B) two runs on the Abbott m2000 and C) one run using the Abbott m2000 maxCycle feature (maxCycle) for co-processing these assays. Cycle times for processing, throughput and hands-on time were evaluated. Overall processing cycle time was 10.3, 9.1 and 7.6 h for Scenarios A), B) and C), respectively. Total hands-on time for each scenario was, in order, 100.0 (A), 90.3 (B) and 61.4 min (C). The interface of an automated analyzer to the laboratory workflow, notably system set up for samples and reagents and clean up functions, are as important as the automation capability of the analyzer for the overall impact to processing efficiency and operator hands-on time.
Participation through Automation: Fully Automated Critical PeakPricing in Commercial Buildings
Energy Technology Data Exchange (ETDEWEB)
Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote,Sila; Linkugel, Eric
2006-06-20
California electric utilities have been exploring the use of dynamic critical peak prices (CPP) and other demand response programs to help reduce peaks in customer electric loads. CPP is a tariff design to promote demand response. Levels of automation in DR can be defined as follows: Manual Demand Response involves a potentially labor-intensive approach such as manually turning off or changing comfort set points at each equipment switch or controller. Semi-Automated Demand Response involves a pre-programmed demand response strategy initiated by a person via centralized control system. Fully Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. The receipt of the external signal initiates pre-programmed demand response strategies. They refer to this as Auto-DR. This paper describes the development, testing, and results from automated CPP (Auto-CPP) as part of a utility project in California. The paper presents the project description and test methodology. This is followed by a discussion of Auto-DR strategies used in the field test buildings. They present a sample Auto-CPP load shape case study, and a selection of the Auto-CPP response data from September 29, 2005. If all twelve sites reached their maximum saving simultaneously, a total of approximately 2 MW of DR is available from these twelve sites that represent about two million ft{sup 2}. The average DR was about half that value, at about 1 MW. These savings translate to about 0.5 to 1.0 W/ft{sup 2} of demand reduction. They are continuing field demonstrations and economic evaluations to pursue increasing penetrations of automated DR that has demonstrated ability to provide a valuable DR resource for California.
The design of an automated electrolytic enrichment apparatus for tritium
Energy Technology Data Exchange (ETDEWEB)
Myers, J.L.
1994-12-01
The Radiation Analytical Sciences Section at Laboratory at Lawrence Livermore National Laboratory performs analysis of low-level tritium concentrations in various natural water samples from the Tri-Valley Area, DOE Nevada Test Site, Site 300 in Tracy, CA, and other various places around the world. Low levels of tritium, a radioactive isotope of hydrogen, which is pre-concentrated in the RAS laboratory using an electrolytic enrichment apparatus. Later these enriched waters are analyzed by liquid scintillation counting to determine the activity of tritium. The enrichment procedure and the subsequent purification process by vacuum distillation are currently undertaken manually, hence being highly labor-intensive. The whole process typically takes about 2 to 3 weeks to complete a batch of 30 samples, with a dedicated personnel operating the process. The goal is to automate the entire process, specifically having the operation PC-LabVIEW{trademark} controlled with real-time monitoring capability. My involvement was in the design and fabrication of a prototypical automated electrolytic enrichment cell. Work will be done on optimizing the electrolytic process by assessing the different parameters of the enrichment procedure. Hardware and software development have also been an integral component of this project.
Complacency and Automation Bias in the Use of Imperfect Automation.
Wickens, Christopher D; Clegg, Benjamin A; Vieane, Alex Z; Sebok, Angelia L
2015-08-01
We examine the effects of two different kinds of decision-aiding automation errors on human-automation interaction (HAI), occurring at the first failure following repeated exposure to correctly functioning automation. The two errors are incorrect advice, triggering the automation bias, and missing advice, reflecting complacency. Contrasts between analogous automation errors in alerting systems, rather than decision aiding, have revealed that alerting false alarms are more problematic to HAI than alerting misses are. Prior research in decision aiding, although contrasting the two aiding errors (incorrect vs. missing), has confounded error expectancy. Participants performed an environmental process control simulation with and without decision aiding. For those with the aid, automation dependence was created through several trials of perfect aiding performance, and an unexpected automation error was then imposed in which automation was either gone (one group) or wrong (a second group). A control group received no automation support. The correct aid supported faster and more accurate diagnosis and lower workload. The aid failure degraded all three variables, but "automation wrong" had a much greater effect on accuracy, reflecting the automation bias, than did "automation gone," reflecting the impact of complacency. Some complacency was manifested for automation gone, by a longer latency and more modest reduction in accuracy. Automation wrong, creating the automation bias, appears to be a more problematic form of automation error than automation gone, reflecting complacency. Decision-aiding automation should indicate its lower degree of confidence in uncertain environments to avoid the automation bias. © 2015, Human Factors and Ergonomics Society.
Synthesis of tracers using automated radiochemistry and robotics
International Nuclear Information System (INIS)
Dannals, R.F.
1992-07-01
Synthesis of high specific activity radiotracers labeled with short-lived positron-emitting radionuclides for positron emission tomography (PET) often requires handling large initial quantities of radioactivity. High specific activities are required when preparing tracers for use in PET studies of neuroreceptors. A fully automated approach for tracer synthesis is highly desirable. This proposal involves the development of a system for the Synthesis of Tracers using Automated Radiochemistry and Robotics (STARR) for this purpose. While the long range objective of the proposed research is the development of a totally automated radiochemistry system for the production of major high specific activity 11 C-radiotracers for use in PET, the specific short range objectives are the automation of 11 C-methyl iodide ( 11 CH 3 I) production via an integrated approach using both radiochemistry modular labstations and robotics, and the extension of this automated capability to the production of several radiotracers for PET (initially, 11 C-methionine, 3-N-[ 11 C-methyl]spiperone, and [ 11 C]-carfentanil)
Saturn facility oil transfer automation system
Energy Technology Data Exchange (ETDEWEB)
Joseph, Nathan R.; Thomas, Rayburn Dean; Lewis, Barbara Ann; Malagon, Hector Ricardo.
2014-02-01
The Saturn accelerator, owned by Sandia National Laboratories, has been in operation since the early 1980s and still has many of the original systems. A critical legacy system is the oil transfer system which transfers 250,000 gallons of transformer oil from outside storage tanks to the Saturn facility. The oil transfer system was iden- ti ed for upgrade to current technology standards. Using the existing valves, pumps, and relay controls, the system was automated using the National Instruments cRIO FGPA platform. Engineered safety practices, including a failure mode e ects analysis, were used to develop error handling requirements. The uniqueness of the Saturn Oil Automated Transfer System (SOATS) is in the graphical user interface. The SOATS uses an HTML interface to communicate to the cRIO, creating a platform independent control system. The SOATS was commissioned in April 2013.
[Automation and organization of technological process of urinalysis].
Kolenkin, S M; Kishkun, A A; Kol'chenko, O L
2000-12-01
Results of introduction into practice of a working model of industrial technology of laboratory studies and KONE Specific Supra and Miditron M devices are shown as exemplified by clinical analysis of the urine. This technology helps standardize all stages and operations, improves the efficiency of quality control of laboratory studies, rationally organizes the work at all stages of the process, creates a system for permanent improvement of the efficiency of investigations at the preanalytical, analytical, and postanalytical stages of technological process of laboratory studies. As a result of introduction of this technology into laboratory practice, violations of quality criteria of clinical urinalysis decreased from 15 to 8% at the preanalytical stage and from 6 to 3% at the analytical stage. Automation of the analysis decreased the need in reagents 3-fold and improved the productivity at the analytical stage 4-fold.
Automating occupational protection records systems
International Nuclear Information System (INIS)
Lyon, M.; Martin, J.B.
1991-10-01
Occupational protection records have traditionally been generated by field and laboratory personnel, assembled into files in the safety office, and eventually stored in a warehouse or other facility. Until recently, these records have been primarily paper copies, often handwritten. Sometimes, the paper is microfilmed for storage. However, electronic records are beginning to replace these traditional methods. The purpose of this paper is to provide guidance for making the transition to automated record keeping and retrieval using modern computer equipment. This paper describes the types of records most readily converted to electronic record keeping and a methodology for implementing an automated record system. The process of conversion is based on a requirements analysis to assess program needs and a high level of user involvement during the development. The importance of indexing the hard copy records for easy retrieval is also discussed. The concept of linkage between related records and its importance relative to reporting, research, and litigation will be addressed. 2 figs
International Nuclear Information System (INIS)
Flament, T.; Goasmat, F.; Poilane, F.
2002-01-01
Managing the operation of large commercial spent nuclear fuel reprocessing plants, such as UP3 and UP2-800 in La Hague, France, requires an extensive analytical program and the shortest possible analysis response times. COGEMA, together with its engineering subsidiary SGN, decided to build high-performance laboratories to support operations in its plants. These laboratories feature automated equipment, safe environments for operators, and short response times, all in centralized installations. Implementation of a computerized analytical data management system and a fully automated pneumatic system for the transfer of radioactive samples was a key factor contributing to the successful operation of the laboratories and plants
Scientific data management in the environmental molecular sciences laboratory
Energy Technology Data Exchange (ETDEWEB)
Bernard, P.R.; Keller, T.L.
1995-09-01
The Environmental Molecular Sciences Laboratory (EMSL) is currently under construction at Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This laboratory will be used for molecular and environmental sciences research to identify comprehensive solutions to DOE`s environmental problems. Major facilities within the EMSL include the Molecular Sciences Computing Facility (MSCF), a laser-surface dynamics laboratory, a high-field nuclear magnetic resonance (NMR) laboratory, and a mass spectrometry laboratory. The EMSL is scheduled to open early in 1997 and will house about 260 resident and visiting scientists. It is anticipated that at least six (6) terabytes of data will be archived in the first year of operation. An object-oriented database management system (OODBMS) and a mass storage system will be integrated to provide an intelligent, automated mechanism to manage data. The resulting system, called the DataBase Computer System (DBCS), will provide total scientific data management capabilities to EMSL users. A prototype mass storage system based on the National Storage Laboratory`s (NSL) UniTree has been procured and is in limited use. This system consists of two independent hierarchies of storage devices. One hierarchy of lower capacity, slower speed devices provides support for smaller files transferred over the Fiber Distributed Data Interface (FDDI) network. Also part of the system is a second hierarchy of higher capacity, higher speed devices that will be used to support high performance clients (e.g., a large scale parallel processor). The ObjectStore OODBMS will be used to manage metadata for archived datasets, maintain relationships between archived datasets, and -hold small, duplicate subsets of archived datasets (i.e., derivative data). The interim system is called DBCS, Phase 0 (DBCS-0). The production system for the EMSL, DBCS Phase 1 (DBCS-1), will be procured and installed in the summer of 1996.
Flemmer, Michael M.; Ham, Jason E.; Wells, J. R.
2007-01-01
A novel system [field and laboratory emission cell (FLEC) automation and control system] has been developed to deliver ozone to a surface utilizing the FLEC to simulate indoor surface chemistry. Ozone, humidity, and air flow rate to the surface were continuously monitored using an ultraviolet ozone monitor, humidity, and flow sensors. Data from these sensors were used as feedback for system control to maintain predetermined experimental parameters. The system was used to investigate the chemistry of ozone with α-terpineol on a vinyl surface over 72h. Keeping all other experimental parameters the same, volatile organic compound emissions from the vinyl tile with α-terpineol were collected from both zero and 100ppb(partsper109) ozone exposures. System stability profiles collected from sensor data indicated experimental parameters were maintained to within a few percent of initial settings. Ozone data from eight experiments at 100ppb (over 339h) provided a pooled standard deviation of 1.65ppb and a 95% tolerance of 3.3ppb. Humidity data from 17 experiments at 50% relative humidity (over 664h) provided a pooled standard deviation of 1.38% and a 95% tolerance of 2.77%. Data of the flow rate of air flowing through the FLEC from 14 experiments at 300ml/min (over 548h) provided a pooled standard deviation of 3.02ml/min and a 95% tolerance range of 6.03ml/min. Initial experimental results yielded long term emissions of ozone/α-terpineol reaction products, suggesting that surface chemistry could play an important role in indoor environments.
Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R
2016-12-01
Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.
An Automated Sample Processing System for Planetary Exploration
Soto, Juancarlos; Lasnik, James; Roark, Shane; Beegle, Luther
2012-01-01
An Automated Sample Processing System (ASPS) for wet chemistry processing of organic materials on the surface of Mars has been jointly developed by Ball Aerospace and the Jet Propulsion Laboratory. The mechanism has been built and tested to demonstrate TRL level 4. This paper describes the function of the system, mechanism design, lessons learned, and several challenges that were overcome.
Available hardware for automated entry control
International Nuclear Information System (INIS)
Holmes, J.P.
1990-01-01
Automated entry control has become an increasingly important issue at facilities where budget constraints are limiting options for manned entry control points. Ongoing work at Sandia National Laboratories is attempting to establish a data base for use by facility security managers working the problem of how to maintain security on a limited budget. Sandia National Laboratories conducted a performance test of the following biometric verifiers: (1) voice verifier by Alpha Microsystems of Santa Ana, California; (2) signature dynamics verifier by Autosig Systems of Irving, Texas; (3) voice verifier by Ecco Industries of Danvers, Massachusetts (now International Electronics); (4) retinal pattern verifier by EyeDentify of Portland, Oregon; (5) fingerprint verifier by Identix of Sunnyvale, California; and (6) hand geometry verifier by Recognition Systems of San Jose, California
Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A
2018-02-01
Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.
Automated, computer interpreted radioimmunoassay results
International Nuclear Information System (INIS)
Hill, J.C.; Nagle, C.E.; Dworkin, H.J.; Fink-Bennett, D.; Freitas, J.E.; Wetzel, R.; Sawyer, N.; Ferry, D.; Hershberger, D.
1984-01-01
90,000 Radioimmunoassay results have been interpreted and transcribed automatically using software developed for use on a Hewlett Packard Model 1000 mini-computer system with conventional dot matrix printers. The computer program correlates the results of a combination of assays, interprets them and prints a report ready for physician review and signature within minutes of completion of the assay. The authors designed and wrote a computer program to query their patient data base for radioassay laboratory results and to produce a computer generated interpretation of these results using an algorithm that produces normal and abnormal interpretives. Their laboratory assays 50,000 patient samples each year using 28 different radioassays. Of these 85% have been interpreted using our computer program. Allowances are made for drug and patient history and individualized reports are generated with regard to the patients age and sex. Finalization of reports is still subject to change by the nuclear physician at the time of final review. Automated, computerized interpretations have realized cost savings through reduced personnel and personnel time and provided uniformity of the interpretations among the five physicians. Prior to computerization of interpretations, all radioassay results had to be dictated and reviewed for signing by one of the resident or staff physicians. Turn around times for reports prior to the automated computer program generally were two to three days. Whereas, the computerized interpret system allows reports to generally be issued the day assays are completed
Mobile teleoperator research at Savannah River Laboratory
International Nuclear Information System (INIS)
Byrd, J.S.
1985-01-01
A Robotics Technology Group was organized at Savannah River Laboratory to employ modern automation and robotics for applications at the Savannah River site. Several industrial robots have been installed in plant processes. Other robotics systems are under development in the laboratories, including mobile teleoperators for general remote tasks and emergency response operations. This paper discusses present work on a low-cost wheeled mobile vehicle, a modular light duty manipulator arm, a large gantry telerobot system, and a high technology six-legged walking robot with a teleoperated arm
High Reproducibility of ELISPOT Counts from Nine Different Laboratories
Directory of Open Access Journals (Sweden)
Srividya Sundararaman
2015-01-01
Full Text Available The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable background intensities. Due to the subjective nature of judging maximal and minimal spot sizes, different investigators come up with different numbers. This study aims to determine whether statistics-based, automated size-gating can harmonize the number of spot counts calculated between different laboratories. We plated PBMC at four different concentrations, 24 replicates each, in an IFN-γ ELISPOT assay with HCMV pp65 antigen. The ELISPOT plate, and an image file of the plate was counted in nine different laboratories using ImmunoSpot® Analyzers by (A Basic Count™ relying on subjective counting parameters set by the respective investigators and (B SmartCount™, an automated counting protocol by the ImmunoSpot® Software that uses statistics-based spot size auto-gating with spot intensity auto-thresholding. The average coefficient of variation (CV for the mean values between independent laboratories was 26.7% when counting with Basic Count™, and 6.7% when counting with SmartCount™. Our data indicates that SmartCount™ allows harmonization of counting ELISPOT results between different laboratories and investigators.
Technological Developments in Networking, Education and Automation
Elleithy, Khaled; Iskander, Magued; Kapila, Vikram; Karim, Mohammad A; Mahmood, Ausif
2010-01-01
"Technological Developments in Networking, Education and Automation" includes a set of rigorously reviewed world-class manuscripts addressing and detailing state-of-the-art research projects in the following areas: Computer Networks: Access Technologies, Medium Access Control, Network architectures and Equipment, Optical Networks and Switching, Telecommunication Technology, and Ultra Wideband Communications. Engineering Education and Online Learning: including development of courses and systems for engineering, technical and liberal studies programs; online laboratories; intelligent
Automation of the Analysis of Moessbauer Spectra
International Nuclear Information System (INIS)
Souza, Paulo A. de Jr.; Garg, R.; Garg, V. K.
1998-01-01
In the present report we propose the automation of least square fitting of Moessbauer spectra, the identification of the substance, its crystal structure and the access to the references with the help of a genetic algorith, Fuzzy logic, and the artificial neural network associated with a databank of Moessbauer parameters and references. This system could be useful for specialists and non-specialists, in industry as well as in research laboratories
The laboratory workforce shortage: a managerial perspective.
Cortelyou-Ward, Kendall; Ramirez, Bernardo; Rotarius, Timothy
2011-01-01
Most clinical laboratories in the nation report severe difficulties in recruitment and retention of most types of personnel. Other important factors impacting this problem include work complexities, increased automation, and a graying workforce. As a further challenge, institutional needs for clinical laboratory personnel are expected to grow significantly in the next decade. This article examines the current situation of the clinical laboratory workforce. It analyzes the different types of personnel; the managerial, supervision, and line positions that are key for different types of laboratories; the job outlook and recent projections for different types of staff; and the current issues, trends, and challenges of the laboratory workforce. Laboratory managers need to take action with strategies suggested for overcoming these challenges. Most importantly, they need to become transformational leaders by developing effective staffing models, fostering healthy and productive work environments, and creating value with a strategic management culture and implementation of knowledge management.
Wet chemical analysis with a laboratory robotic system
International Nuclear Information System (INIS)
Burkett, S.D.; Dyches, G.M.; Spencer, W.A.
1984-01-01
Emphasis on laboratory automation has increased in recent years. The desire to improve analytical reliability, increase productivity, and reduce exposure of personnel to hazardous materials has been fundamental to this increase. The Savannah River Laboratory (SRL) performs research and development on nuclear materials. Development of methods to increase efficiency and safety and to reduce exposure of personnel to radioactive materials is an ongoing process at our site. Robotic systems offer a potentially attractive way to achieve these goals
ICECAP: an integrated, general-purpose, automation-assisted IC50/EC50 assay platform.
Li, Ming; Chou, Judy; King, Kristopher W; Jing, Jing; Wei, Dong; Yang, Liyu
2015-02-01
IC50 and EC50 values are commonly used to evaluate drug potency. Mass spectrometry (MS)-centric bioanalytical and biomarker labs are now conducting IC50/EC50 assays, which, if done manually, are tedious and error-prone. Existing bioanalytical sample preparation automation systems cannot meet IC50/EC50 assay throughput demand. A general-purpose, automation-assisted IC50/EC50 assay platform was developed to automate the calculations of spiking solutions and the matrix solutions preparation scheme, the actual spiking and matrix solutions preparations, as well as the flexible sample extraction procedures after incubation. In addition, the platform also automates the data extraction, nonlinear regression curve fitting, computation of IC50/EC50 values, graphing, and reporting. The automation-assisted IC50/EC50 assay platform can process the whole class of assays of varying assay conditions. In each run, the system can handle up to 32 compounds and up to 10 concentration levels per compound, and it greatly improves IC50/EC50 assay experimental productivity and data processing efficiency. © 2014 Society for Laboratory Automation and Screening.
Automated, High Temperature Furnace for Glovebox Operation
International Nuclear Information System (INIS)
Neikirk, K.
2001-01-01
The Plutonium Immobilization Project (PIP), to be located at the Savannah River Site SRS, is a combined development and testing effort by Lawrence Livermore National Laboratory (LLNL), Westinghouse Savannah River Company (WSRC), Pacific Northwest National Laboratory (PNNL), Argonne National Laboratory (ANL), and the Australian National Science and Technology Organization (ANSTO). The Plutonium Immobilization process involves the disposition of excess plutonium by incorporation into ceramic pucks. As part of the immobilization process, furnaces are needed for sintering the ceramic pucks. The furnace being developed for puck sintering is an automated, bottom loaded furnace with insulating package and resistance heating elements located within a nuclear glovebox. Other furnaces types considered for the application include retort furnaces and pusher furnaces. This paper, in part, will discuss the furnace technologies considered and furnace technology selected to support reliable puck sintering in a glovebox environment
Improving the driver-automation interaction: an approach using automation uncertainty.
Beller, Johannes; Heesen, Matthias; Vollrath, Mark
2013-12-01
The aim of this study was to evaluate whether communicating automation uncertainty improves the driver-automation interaction. A false system understanding of infallibility may provoke automation misuse and can lead to severe consequences in case of automation failure. The presentation of automation uncertainty may prevent this false system understanding and, as was shown by previous studies, may have numerous benefits. Few studies, however, have clearly shown the potential of communicating uncertainty information in driving. The current study fills this gap. We conducted a driving simulator experiment, varying the presented uncertainty information between participants (no uncertainty information vs. uncertainty information) and the automation reliability (high vs.low) within participants. Participants interacted with a highly automated driving system while engaging in secondary tasks and were required to cooperate with the automation to drive safely. Quantile regressions and multilevel modeling showed that the presentation of uncertainty information increases the time to collision in the case of automation failure. Furthermore, the data indicated improved situation awareness and better knowledge of fallibility for the experimental group. Consequently, the automation with the uncertainty symbol received higher trust ratings and increased acceptance. The presentation of automation uncertaintythrough a symbol improves overall driver-automation cooperation. Most automated systems in driving could benefit from displaying reliability information. This display might improve the acceptance of fallible systems and further enhances driver-automation cooperation.
Development of a free software for laboratory of metrology
International Nuclear Information System (INIS)
Silveira, Renata R. da; Benevides, Clayton A.
2014-01-01
The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) has a Metrology Laboratory to realize radioactive assays and calibrations in X and gamma radiation. This job, realized before in a manual way, had only paper recording and a hard-working data recovery. The objective of this job was to develop an application with free software to manage the laboratory activities, as service recording, rastreability control and environmental conditions monitoring, beyond automate the certificates and reports. As result, we have obtained the optimization of the routine and the management of the laboratory. (author)
Development of an automated core model for nuclear reactors
International Nuclear Information System (INIS)
Mosteller, R.D.
1998-01-01
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The objective of this project was to develop an automated package of computer codes that can model the steady-state behavior of nuclear-reactor cores of various designs. As an added benefit, data produced for steady-state analysis also can be used as input to the TRAC transient-analysis code for subsequent safety analysis of the reactor at any point in its operating lifetime. The basic capability to perform steady-state reactor-core analysis already existed in the combination of the HELIOS lattice-physics code and the NESTLE advanced nodal code. In this project, the automated package was completed by (1) obtaining cross-section libraries for HELIOS, (2) validating HELIOS by comparing its predictions to results from critical experiments and from the MCNP Monte Carlo code, (3) validating NESTLE by comparing its predictions to results from numerical benchmarks and to measured data from operating reactors, and (4) developing a linkage code to transform HELIOS output into NESTLE input
Energy Technology Data Exchange (ETDEWEB)
Lekov, Alex; Thompson, Lisa; McKane, Aimee; Song, Katherine; Piette, Mary Ann
2009-04-01
This report summarizes the Lawrence Berkeley National Laboratory?s research to date in characterizing energy efficiency and automated demand response opportunities for wastewater treatment facilities in California. The report describes the characteristics of wastewater treatment facilities, the nature of the wastewater stream, energy use and demand, as well as details of the wastewater treatment process. It also discusses control systems and energy efficiency and automated demand response opportunities. In addition, several energy efficiency and load management case studies are provided for wastewater treatment facilities.This study shows that wastewater treatment facilities can be excellent candidates for open automated demand response and that facilities which have implemented energy efficiency measures and have centralized control systems are well-suited to shift or shed electrical loads in response to financial incentives, utility bill savings, and/or opportunities to enhance reliability of service. Control technologies installed for energy efficiency and load management purposes can often be adapted for automated demand response at little additional cost. These improved controls may prepare facilities to be more receptive to open automated demand response due to both increased confidence in the opportunities for controlling energy cost/use and access to the real-time data.
Laboratory automation: a challenge for the 1990s
Mordini, Claude
1994-01-01
There is tremendous pressure on industry and laboratories to develop increasingly complex procucts: for example catalysts, chiral chemicals, drugs and ceramics; conform to regulations; cope with increasingly severe competition; and meet steadily increasing costs. It is difficult, in this situation, to remain productive and competitive. It is vital to be equipped with, and be able to use appropriately, all the suitable methodologies and technologies. Working methods and personnel have to be ap...
Automated real-time software development
Jones, Denise R.; Walker, Carrie K.; Turkovich, John J.
1993-01-01
A Computer-Aided Software Engineering (CASE) system has been developed at the Charles Stark Draper Laboratory (CSDL) under the direction of the NASA Langley Research Center. The CSDL CASE tool provides an automated method of generating source code and hard copy documentation from functional application engineering specifications. The goal is to significantly reduce the cost of developing and maintaining real-time scientific and engineering software while increasing system reliability. This paper describes CSDL CASE and discusses demonstrations that used the tool to automatically generate real-time application code.
A HUMAN AUTOMATION INTERACTION CONCEPT FOR A SMALL MODULAR REACTOR CONTROL ROOM
Energy Technology Data Exchange (ETDEWEB)
Le Blanc, Katya; Spielman, Zach; Hill, Rachael
2017-06-01
Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Additionally, many new reactor concepts, both full scale and small modular reactors, are proposing increased automation and reduced staffing as part of their concept of operations. However, research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. There is a need to address the question of how to achieve high performance and efficiency of high levels of automation without degrading human performance. One example of a new NPP concept that will utilize greater degrees of automation is the SMR concept from NuScale Power. The NuScale Power design requires 12 modular units to be operated in one single control room, which leads to a need for higher degrees of automation in the control room. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed.
Sample handling and transport for the Secure Automated Fabrication line
International Nuclear Information System (INIS)
Sherrell, D.L.; Jensen, J.D.; Genoway, G.G.; Togesen, H.J.
1983-06-01
A totally automated system is described which packages, transports, receives, and unpackages sintered plutonium/uranium oxide fuel pellet samples to support automated chemical analysis equipment for the Secure Automated Fabrication (SAF) line. Samples are transferred 100 meters from the fuel production line to a different floor of the facility where automatic determinations are made for purposes of process control and fuel quality certification. The system automatically records identification numbers, net weights sent and received, and all other pertinent information such as fuel lot number, sample point, date, and time of day
Automated statistical modeling of analytical measurement systems
International Nuclear Information System (INIS)
Jacobson, J.J.
1992-01-01
The statistical modeling of analytical measurement systems at the Idaho Chemical Processing Plant (ICPP) has been completely automated through computer software. The statistical modeling of analytical measurement systems is one part of a complete quality control program used by the Remote Analytical Laboratory (RAL) at the ICPP. The quality control program is an integration of automated data input, measurement system calibration, database management, and statistical process control. The quality control program and statistical modeling program meet the guidelines set forth by the American Society for Testing Materials and American National Standards Institute. A statistical model is a set of mathematical equations describing any systematic bias inherent in a measurement system and the precision of a measurement system. A statistical model is developed from data generated from the analysis of control standards. Control standards are samples which are made up at precise known levels by an independent laboratory and submitted to the RAL. The RAL analysts who process control standards do not know the values of those control standards. The object behind statistical modeling is to describe real process samples in terms of their bias and precision and, to verify that a measurement system is operating satisfactorily. The processing of control standards gives us this ability
ROBOCAL: An automated NDA [nondestructive analysis] calorimetry and gamma isotopic system
International Nuclear Information System (INIS)
Hurd, J.R.; Powell, W.D.; Ostenak, C.A.
1989-01-01
ROBOCAL, which is presently being developed and tested at Los Alamos National Laboratory, is a full-scale, prototype robotic system for remote calorimetric and gamma-ray analysis of special nuclear materials. It integrates a fully automated, multidrawer, vertical stacker-retriever system for staging unmeasured nuclear materials, and a fully automated gantry robot for computer-based selection and transfer of nuclear materials to calorimetric and gamma-ray measurement stations. Since ROBOCAL is designed for minimal operator intervention, a completely programmed user interface is provided to interact with the automated mechanical and assay systems. The assay system is designed to completely integrate calorimetric and gamma-ray data acquisition and to perform state-of-the-art analyses on both homogeneous and heterogeneous distributions of nuclear materials in a wide variety of matrices
Sosik, H. M.; Olson, R. J.; Brownlee, E.; Brosnahan, M.; Crockford, E. T.; Peacock, E.; Shalapyonok, A.
2016-12-01
Imaging FlowCytobot (IFCB) was developed to fill a need for automated identification and monitoring of nano- and microplankton, especially phytoplankton in the size range 10 200 micrometer, which are important in coastal blooms (including harmful algal blooms). IFCB uses a combination of flow cytometric and video technology to capture high resolution (1 micrometer) images of suspended particles. This proven, now commercially available, submersible instrument technology has been deployed in fixed time series locations for extended periods (months to years) and in shipboard laboratories where underway water is automatically analyzed during surveys. Building from these successes, we have now constructed and evaluated three new prototype IFCB designs that extend measurement and deployment capabilities. To improve cell counting statistics without degrading image quality, a high throughput version (IFCB-HT) incorporates in-flow acoustic focusing to non-disruptively pre-concentrate cells before the measurement area of the flow cell. To extend imaging to all heterotrophic cells (even those that do not exhibit chlorophyll fluorescence), Staining IFCB (IFCB-S) incorporates automated addition of a live-cell fluorescent stain (fluorescein diacetate) to samples before analysis. A horizontally-oriented IFCB-AV design addresses the need for spatial surveying from surface autonomous vehicles, including design features that reliably eliminate air bubbles and mitigate wave motion impacts. Laboratory evaluation and test deployments in waters near Woods Hole show the efficacy of each of these enhanced IFCB designs.
Is automated platelet counting still a problem in thrombocytopenic blood?
Directory of Open Access Journals (Sweden)
Raimundo Antônio Gomes Oliveira
Full Text Available CONTEXT: Reliable platelet counting is crucial for indicating prophylactic platelet transfusion in thrombocytopenic patients. OBJECTIVE: To evaluate the precision and accuracy of platelet counting for thrombocytopenic patients, using four different automated counters in comparison with the Brecher & Cronkite reference method recommended by the International Committee for Standardization in Hematology (ICSH. TYPE OF STUDY: Automated platelet counting assessment in thrombocytopenic patients. SETTING: Hematology Laboratory, Hospital do Servidor Público Estadual de São Paulo, and the Hematology Division of Instituto Adolfo Lutz, São Paulo, SP, Brazil. MAIN MEASUREMENTS: Brecher & Cronkite reference method and four different automated platelet counters. PARTICIPANTS: 43 thrombocytopenic patients with platelet counts of less than 30,000/µl RESULTS: The ADVIA-120 (Bayer, Coulter STKS, H1 System (Technicom-Bayer and Coulter T-890 automatic instruments presented great precision and accuracy in relation to laboratory thrombocytopenic samples obtained by diluting blood from normal donors. However, when thrombocytopenic patients were investigated, all the counters except ADVIA (which is based on volume and refraction index showed low accuracy when compared to the Brecher & Cronkite reference method (ICSH. The ADVIA counter showed high correlation (r = 0.947. However, all counters showed flags in thrombocytopenic samples. CONCLUSION: The Brecher & Cronkite reference method should always be indicated in thrombocytopenic patients for platelet counts below 30,000 plt /µl obtained in one dimensional counters.
Automation software for a materials testing laboratory
Mcgaw, Michael A.; Bonacuse, Peter J.
1990-01-01
The software environment in use at the NASA-Lewis Research Center's High Temperature Fatigue and Structures Laboratory is reviewed. This software environment is aimed at supporting the tasks involved in performing materials behavior research. The features and capabilities of the approach to specifying a materials test include static and dynamic control mode switching, enabling multimode test control; dynamic alteration of the control waveform based upon events occurring in the response variables; precise control over the nature of both command waveform generation and data acquisition; and the nesting of waveform/data acquisition strategies so that material history dependencies may be explored. To eliminate repetitive tasks in the coventional research process, a communications network software system is established which provides file interchange and remote console capabilities.
Development of an Automated Security Risk Assessment Methodology Tool for Critical Infrastructures.
Energy Technology Data Exchange (ETDEWEB)
Jaeger, Calvin Dell; Roehrig, Nathaniel S.; Torres, Teresa M.
2008-12-01
This document presents the security automated Risk Assessment Methodology (RAM) prototype tool developed by Sandia National Laboratories (SNL). This work leverages SNL's capabilities and skills in security risk analysis and the development of vulnerability assessment/risk assessment methodologies to develop an automated prototype security RAM tool for critical infrastructures (RAM-CITM). The prototype automated RAM tool provides a user-friendly, systematic, and comprehensive risk-based tool to assist CI sector and security professionals in assessing and managing security risk from malevolent threats. The current tool is structured on the basic RAM framework developed by SNL. It is envisioned that this prototype tool will be adapted to meet the requirements of different CI sectors and thereby provide additional capabilities.
Lippi, Giuseppe; Ippolito, Luigi; Favaloro, Emmanuel J
2013-10-01
Automation in hemostasis testing is entering an exciting and unprecedented phase. This study was planned to assess the performance of the new preanalytical module on the hemostasis testing system Instrumentation Laboratory ACL TOP. The evaluation included interference studies to define reliable thresholds for rejecting samples with significant concentrations of interfering substances; within-run imprecision studies of plasma indices on four different interference degrees for each index; comparison studies with reference measures of hemolysis index, bilirubin, and triglycerides on clinical chemistry analyzers; and calculation of turnaround time with and without automatic performance of preanalytical check. The upper limits for sample rejection according to our interference studies were 3.6 g/L for hemoglobin, 13.6 mg/dL for bilirubin, and 1454 mg/dL for triglycerides. We found optimal precision for all indices (0.6% to 3.1% at clinically relevant thresholds) and highly significant correlations with reference measures on clinical chemistry analyzers (from 0.985 to 0.998). The limited increase of turnaround time (i.e., +3% and +5% with or without cap-piercing), coupled with no adjunctive costs over performance of normal coagulation assays, contribute to make the automatic check of plasma indices on ACL TOP a reliable and practical approach for improving testing quality and safeguarding patient safety.
Focke, Maximilian; Mark, Daniel; Stumpf, Fabian; Müller, Martina; Roth, Günter; Zengerle, Roland; von Stetten, Felix
2011-06-01
Two microfluidic cartridges intended for upgrading standard laboratory instruments with automated liquid handling capability by use of centrifugal forces are presented. The first microfluidic cartridge enables purification of DNA from human whole blood and is operated in a standard laboratory centrifuge. The second microfluidic catridge enables genotyping of pathogens by geometrically multiplexed real-time PCR. It is operated in a slightly modified off-the-shelf thermal cycler. Both solutions aim at smart and cost-efficient ways to automate work flows in laboratories. The DNA purification cartridge automates all liquid handling steps starting from a lysed blood sample to PCR ready DNA. The cartridge contains two manually crushable glass ampoules with liquid reagents. The DNA yield extracted from a 32 μl blood sample is 192 +/- 30 ng which corresponds to 53 +/- 8% of a reference extraction. The genotyping cartridge is applied to analyse isolates of the multi-resistant Staphyloccus aureus (MRSA) by real-time PCR. The wells contain pre-stored dry reagents such as primers and probes. Evaluation of the system with 44 genotyping assays showed a 100% specificity and agreement with the reference assays in standard tubes. The lower limit of detection was well below 10 copies of DNA per reaction.
Development of an automated asbestos counting software based on fluorescence microscopy.
Alexandrov, Maxym; Ichida, Etsuko; Nishimura, Tomoki; Aoki, Kousuke; Ishida, Takenori; Hirota, Ryuichi; Ikeda, Takeshi; Kawasaki, Tetsuo; Kuroda, Akio
2015-01-01
An emerging alternative to the commonly used analytical methods for asbestos analysis is fluorescence microscopy (FM), which relies on highly specific asbestos-binding probes to distinguish asbestos from interfering non-asbestos fibers. However, all types of microscopic asbestos analysis require laborious examination of large number of fields of view and are prone to subjective errors and large variability between asbestos counts by different analysts and laboratories. A possible solution to these problems is automated counting of asbestos fibers by image analysis software, which would lower the cost and increase the reliability of asbestos testing. This study seeks to develop a fiber recognition and counting software for FM-based asbestos analysis. We discuss the main features of the developed software and the results of its testing. Software testing showed good correlation between automated and manual counts for the samples with medium and high fiber concentrations. At low fiber concentrations, the automated counts were less accurate, leading us to implement correction mode for automated counts. While the full automation of asbestos analysis would require further improvements in accuracy of fiber identification, the developed software could already assist professional asbestos analysts and record detailed fiber dimensions for the use in epidemiological research.
Linget, J M; du Vignaud, P
1999-05-01
A 215 Gilson liquid handler was used to automate enzymatic incubations using microsomes, cytosol and plasma. The design of automated protocols are described. They were based on the use of 96 deep well plates and on HPLC-based methods for assaying the substrate. The assessment of those protocols was made with comparison between manual and automated incubations, reliability and reproducibility of automated incubations in microsomes and cytosol. Examples of the use of those programs in metabolic studies in drug research, i.e. metabolic screening in microsomes and plasma were shown. Even rapid processes (with disappearance half lives as low as 1 min) can be analysed. This work demonstrates how stability studies can be automated to save time, render experiments involving human biological media less hazardous and may be improve inter-laboratory reproducibility.
Transport Energy Impact Analysis; NREL (National Renewable Energy Laboratory)
Energy Technology Data Exchange (ETDEWEB)
Gonder, J.
2015-05-13
Presented at the Sustainable Transportation Energy Pathways Spring 2015 Symposium on May 13, 2015, this presentation by Jeff Gonder of the National Renewable Energy Laboratory (NREL) provides information about NREL's transportation energy impact analysis of connected and automated vehicles.
Monitoring system of the Tritium Research Laboratory, Sandia Laboratories, Livermore, CA
International Nuclear Information System (INIS)
Wall, W.R.; Hafner, R.S.; Westfall, D.L.; Ristau, R.D.
1978-11-01
Automated tritium monitoring is now in use at the Tritium Research Laboratory (TRL). Betatec 100 tritium monitors, along with several Sandia-designed accessories, have been combined with a PDP 11/40 computer to automatically read and record tritium concentrations of room air, containment, and cleanup systems. Each individual monitoring system, in addition to a local display in the area of interest, has a visible/audible display in the control room. Each system is then channeled into the PDP 11/40 computer, providing immediate assessment of the status of the entire laboratory from a central location. Measurement capability ranges from μCi/m 3 levels for room air monitoring to kCi/m 3 levels for glove box and cleanup systems monitoring. In this report the overall monitoring system and its capabilities are discussed, with detailed descriptions given of monitors and their components
Status of automated nuclear scanning systems
International Nuclear Information System (INIS)
Gold, R.; Roberts, J.H.; Preston, C.C.; McNeece, J.P.; Ruddy, F.H.
1983-07-01
Present day minicomputers and microprocessors enable a range of automation, from partial to total, of tasks once thought beyond approach. The status of three computer controlled systems for quantitative track measurements is reviewed. Two systems, the Hanford optical track scanner (HOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third systems, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Current limitations of these systems for quantitative track scanning are presented. Experimental uncertainties attained with these computer controlled systems are described using results obtained from reactor neutron dosimetry
Pogorelov, Vladimir M; Lanthorn, Thomas H; Savelieva, Katerina V
2007-05-15
The present report describes a setup for simultaneously measuring anxiety-like behaviors and locomotor activity in mice. Animals are placed in a brightly lit, standard automated open-field (OF) in which a rectangular ceramic platform 8 cm high covers one quadrant of the floor. Mice preferred to stay under the platform, avoiding the area with bright illumination. Activities under and outside the platform were measured for 5 min. Chlordiazepoxide and buspirone dose-dependently increased time spent outside the platform (L-Time) and the light distance to total OF distance ratio (L:T-TD) in both genders without changing total OF distance. By contrast, amphetamine decreased L-Time and L:T-TD in males, thus displaying an anxiogenic effect. Imipramine was without selective effect on L-Time or L:T-TD, but decreased total OF distance at the highest dose indicative of a sedative effect. Drug effects were also evaluated in the OF without platform using conventional anxiety measures. Introduction of the platform into the OF apparatus strongly enhanced the sensitivity to anxiolytics. Comparison of strains differing in activity or anxiety levels showed that L-Time and L:T-TD can be used as measures of anxiety-like behavior independent of locomotor activity. Changes in motor activity are reflected in the total distance traveled under and outside the platform. Therefore, the platform test is fully automated, sensitive to both anxiolytic and anxiogenic effects of drugs and genetic phenotypes with little evidence of gender-specific responses, and can be easily utilized by most laboratories measuring behavior.
Automated Inadvertent Intruder Application
International Nuclear Information System (INIS)
Koffman, Larry D.; Lee, Patricia L.; Cook, James R.; Wilhite, Elmer L.
2008-01-01
The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and
Enjeti, Anoop; Granter, Neil; Ashraf, Asma; Fletcher, Linda; Branford, Susan; Rowlings, Philip; Dooley, Susan
2015-10-01
An automated cartridge-based detection system (GeneXpert; Cepheid) is being widely adopted in low throughput laboratories for monitoring BCR-ABL1 transcript in chronic myelogenous leukaemia. This Australian study evaluated the longitudinal performance specific characteristics of the automated system.The automated cartridge-based system was compared prospectively with the manual qRT-PCR-based reference method at SA Pathology, Adelaide, over a period of 2.5 years. A conversion factor determination was followed by four re-validations. Peripheral blood samples (n = 129) with international scale (IS) values within detectable range were selected for assessment. The mean bias, proportion of results within specified fold difference (2-, 3- and 5-fold), the concordance rate of major molecular remission (MMR) and concordance across a range of IS values on paired samples were evaluated.The initial conversion factor for the automated system was determined as 0.43. Except for the second re-validation, where a negative bias of 1.9-fold was detected, all other biases fell within desirable limits. A cartridge-specific conversion factor and efficiency value was introduced and the conversion factor was confirmed to be stable in subsequent re-validation cycles. Concordance with the reference method/laboratory at >0.1-≤10 IS was 78.2% and at ≤0.001 was 80%, compared to 86.8% in the >0.01-≤0.1 IS range. The overall and MMR concordance were 85.7% and 94% respectively, for samples that fell within ± 5-fold of the reference laboratory value over the entire period of study.Conversion factor and performance specific characteristics for the automated system were longitudinally stable in the clinically relevant range, following introduction by the manufacturer of lot specific efficiency values.
International Nuclear Information System (INIS)
1987-03-01
This book indicates method of building of automation plan, design of automation facilities, automation and CHIP process like basics of cutting, NC processing machine and CHIP handling, automation unit, such as drilling unit, tapping unit, boring unit, milling unit and slide unit, application of oil pressure on characteristics and basic oil pressure circuit, application of pneumatic, automation kinds and application of process, assembly, transportation, automatic machine and factory automation.
İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman
2016-08-01
Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.
Oak Ridge National Laboratory Review
Energy Technology Data Exchange (ETDEWEB)
Krause, C.; Pearce, J.; Zucker, A. (eds.)
1992-01-01
This report presents brief descriptions of the following programs at Oak Ridge National Laboratory: The effects of pollution and climate change on forests; automation to improve the safety and efficiency of rearming battle tanks; new technologies for DNA sequencing; ORNL probes the human genome; ORNL as a supercomputer research center; paving the way to superconcrete made with polystyrene; a new look at supercritical water used in waste treatment; and small mammals as environmental monitors.
International Nuclear Information System (INIS)
Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar
2014-01-01
Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)
Energy Technology Data Exchange (ETDEWEB)
Kim, Joyce Jihyun [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schetrit, Oren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yin, Rongxin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kiliccote, Sila [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
2014-05-01
Demand response (DR) – allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern – continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. From October 2011 to December 2013, the Demand Response Research Center at Lawrence Berkeley National Laboratory, the New York State Energy Research and Development Authority, and partners Honeywell and Akuacom, have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR) communication protocols. In particular, this project focuses on demonstrating how the OpenADR platform, enabled by Akuacom, can automate and simplify interactions between buildings and various stakeholders in New York State and enable the automation of customers’ price response to yield bill savings under dynamic pricing. In this paper, the cost control opportunities under day-ahead hourly pricing and Auto-DR control strategies are presented for four demonstration buildings; present the breakdown of Auto-DR enablement costs; summarize the field test results and their load impact; and show potential bill savings by enabling automated price response under Consolidated Edison’s Mandatory Hourly Pricing (MHP) tariff. For one of the sites, the potential bill savings at the site’s current retail rate are shown. Facility managers were given granular equipment-level opt-out capability to ensure full control of the sites during the Auto-DR implementation. The expected bill savings ranged from 1.1% to 8.0% of the total MHP bill. The automation and enablement costs ranged from $70 to $725 per kW shed. The results show that OpenADR can facilitate the automation of price response, deliver savings to the customers and opt-out capability of the implementation retains control of the
Supervised learning for the automated transcription of spacer classification from spoligotype films
Directory of Open Access Journals (Sweden)
Abernethy Neil
2009-08-01
Full Text Available Abstract Background Molecular genotyping of bacteria has revolutionized the study of tuberculosis epidemiology, yet these established laboratory techniques typically require subjective and laborious interpretation by trained professionals. In the context of a Tuberculosis Case Contact study in The Gambia we used a reverse hybridization laboratory assay called spoligotype analysis. To facilitate processing of spoligotype images we have developed tools and algorithms to automate the classification and transcription of these data directly to a database while allowing for manual editing. Results Features extracted from each of the 1849 spots on a spoligo film were classified using two supervised learning algorithms. A graphical user interface allows manual editing of the classification, before export to a database. The application was tested on ten films of differing quality and the results of the best classifier were compared to expert manual classification, giving a median correct classification rate of 98.1% (inter quartile range: 97.1% to 99.2%, with an automated processing time of less than 1 minute per film. Conclusion The software implementation offers considerable time savings over manual processing whilst allowing expert editing of the automated classification. The automatic upload of the classification to a database reduces the chances of transcription errors.
Massambu, Charles; Mwangi, Christina
2009-06-01
The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.
ELAN - expert system supported information and management system for analytical laboratories
International Nuclear Information System (INIS)
Jaeschke, A.; Orth, H.; Zilly, G.
1990-08-01
The demand for high efficiency and short response time calls for the use of computer support in chemico-analytical laboratories. This is usually achieved by laboratory information and management systems covering the three levels of analytical instrument automation, laboratory operation support and laboratory management. The management component of the systems implemented up to now suffers from a lack of flexibility as far as unforeseen analytical investigations outside the laboratory routine work are concerned. Another drawback is the lack of adaptability with respect to structural changes in laboratory organization. It can be eliminated by the application of expert system structures and methods for the implementation of this system level. The ELAN laboratory information and management system has been developed on the basis of this concept. (orig.) [de
Laboratory errors and patient safety.
Miligy, Dawlat A
2015-01-01
Laboratory data are extensively used in medical practice; consequently, laboratory errors have a tremendous impact on patient safety. Therefore, programs designed to identify and reduce laboratory errors, as well as, setting specific strategies are required to minimize these errors and improve patient safety. The purpose of this paper is to identify part of the commonly encountered laboratory errors throughout our practice in laboratory work, their hazards on patient health care and some measures and recommendations to minimize or to eliminate these errors. Recording the encountered laboratory errors during May 2008 and their statistical evaluation (using simple percent distribution) have been done in the department of laboratory of one of the private hospitals in Egypt. Errors have been classified according to the laboratory phases and according to their implication on patient health. Data obtained out of 1,600 testing procedure revealed that the total number of encountered errors is 14 tests (0.87 percent of total testing procedures). Most of the encountered errors lay in the pre- and post-analytic phases of testing cycle (representing 35.7 and 50 percent, respectively, of total errors). While the number of test errors encountered in the analytic phase represented only 14.3 percent of total errors. About 85.7 percent of total errors were of non-significant implication on patients health being detected before test reports have been submitted to the patients. On the other hand, the number of test errors that have been already submitted to patients and reach the physician represented 14.3 percent of total errors. Only 7.1 percent of the errors could have an impact on patient diagnosis. The findings of this study were concomitant with those published from the USA and other countries. This proves that laboratory problems are universal and need general standardization and bench marking measures. Original being the first data published from Arabic countries that
Explicit control of adaptive automation under different levels of environmental stress.
Sauer, Jürgen; Kao, Chung-Shan; Wastell, David; Nickel, Peter
2011-08-01
This article examines the effectiveness of three different forms of explicit control of adaptive automation under low- and high-stress conditions, operationalised by different levels of noise. In total, 60 participants were assigned to one of three types of automation design (free, prompted and forced choice). They were trained for 4 h on a highly automated simulation of a process control environment, called AutoCAMS. This was followed by a 4-h testing session under noise exposure and quiet conditions. Measures of performance, psychophysiology and subjective reactions were taken. The results showed that all three modes of explicit control of adaptive automation modes were able to attenuate the negative effects of noise. This was partly due to the fact that operators opted for higher levels of automation under noise. It also emerged that forced choice showed marginal advantages over the two other automation modes. Statement of Relevance: This work is relevant to the design of adaptive automation since it emphasises the need to consider the impact of work-related stressors during task completion. During the presence of stressors, different forms of operator support through automation may be required than under more favourable working conditions.
IFDOTMETER: A New Software Application for Automated Immunofluorescence Analysis.
Rodríguez-Arribas, Mario; Pizarro-Estrella, Elisa; Gómez-Sánchez, Rubén; Yakhine-Diop, S M S; Gragera-Hidalgo, Antonio; Cristo, Alejandro; Bravo-San Pedro, Jose M; González-Polo, Rosa A; Fuentes, José M
2016-04-01
Most laboratories interested in autophagy use different imaging software for managing and analyzing heterogeneous parameters in immunofluorescence experiments (e.g., LC3-puncta quantification and determination of the number and size of lysosomes). One solution would be software that works on a user's laptop or workstation that can access all image settings and provide quick and easy-to-use analysis of data. Thus, we have designed and implemented an application called IFDOTMETER, which can run on all major operating systems because it has been programmed using JAVA (Sun Microsystems). Briefly, IFDOTMETER software has been created to quantify a variety of biological hallmarks, including mitochondrial morphology and nuclear condensation. The program interface is intuitive and user-friendly, making it useful for users not familiar with computer handling. By setting previously defined parameters, the software can automatically analyze a large number of images without the supervision of the researcher. Once analysis is complete, the results are stored in a spreadsheet. Using software for high-throughput cell image analysis offers researchers the possibility of performing comprehensive and precise analysis of a high number of images in an automated manner, making this routine task easier. © 2015 Society for Laboratory Automation and Screening.
Parallelize Automated Tests in a Build and Test Environment
Durairaj, Selva Ganesh
2016-01-01
This thesis investigates the possibilities of finding solutions, in order to reduce the total time spent for testing and waiting times for running multiple automated test cases in a test framework. The “Automated Test Framework”, developed by Axis Communications AB, is used to write the functional tests to test both hardware and software of a resource. The functional tests that tests the software is considered in this thesis work. In the current infrastructure, tests are executed sequentially...
Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S
2018-07-01
4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.
Shively, Jay
2017-01-01
A significant level of debate and confusion has surrounded the meaning of the terms autonomy and automation. Automation is a multi-dimensional concept, and we propose that Remotely Piloted Aircraft Systems (RPAS) automation should be described with reference to the specific system and task that has been automated, the context in which the automation functions, and other relevant dimensions. In this paper, we present definitions of automation, pilot in the loop, pilot on the loop and pilot out of the loop. We further propose that in future, the International Civil Aviation Organization (ICAO) RPAS Panel avoids the use of the terms autonomy and autonomous when referring to automated systems on board RPA. Work Group 7 proposes to develop, in consultation with other workgroups, a taxonomy of Levels of Automation for RPAS.
Preliminary design of a production automation framework for a pyroprocessing facility
Directory of Open Access Journals (Sweden)
Moonsoo Shin
2018-04-01
Full Text Available Pyroprocessing technology has been regarded as a promising solution for recycling spent fuel in nuclear power plants. The Korea Atomic Energy Research Institute has been studying the current status of equipment and facilities for pyroprocessing and found that existing facilities are manually operated; therefore, their applications have been limited to laboratory scale because of low productivity and safety concerns. To extend the pyroprocessing technology to a commercial scale, the facility, including all the processing equipment and the material-handling devices, should be enhanced in view of automation. In an automated pyroprocessing facility, a supervised control system is needed to handle and manage material flow and associated operations. This article provides a preliminary design of the supervising system for pyroprocessing. In particular, a manufacturing execution system intended for an automated pyroprocessing facility, named Pyroprocessing Execution System, is proposed, by which the overall production process is automated via systematic collaboration with a planning system and a control system. Moreover, a simulation-based prototype system is presented to illustrate the operability of the proposed Pyroprocessing Execution System, and a simulation study to demonstrate the interoperability of the material-handling equipment with processing equipment is also provided. Keywords: Manufacturing Execution System, Material-handling, Production Automation, Production Planning and Control, Pyroprocessing, Pyroprocessing Execution System
Energy management through building automation. Fundamentals - Technologies - Applications
International Nuclear Information System (INIS)
Aschendorf, Bernd
2014-01-01
The books available in the market consider only the use of individual buildings bus systems, but not to compare with each other with respect to cost-benefit and applicability. In this book, a total of 40 different systems, such as radio bus systems, PEHA-PHC, EIB, LCN, LON, PLC systems, investigated for their possible use in the various categories of buildings. The comparison refers to all levels of the automation pyramid from fieldbus, to automation to the control level and considers in particular the usability for SmartMetering-based energy management. [de
Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116
Energy Technology Data Exchange (ETDEWEB)
Burge, Scott R. [Burge Environmental, Inc., 6100 South Maple Avenue, no. 114, Tempe, AZ, 85283 (United States); O' Hara, Matthew J. [Pacific Northwest National Laboratory, 902 Battelle Blvd., Richland, WA, 99352 (United States)
2013-07-01
An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated
Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116
International Nuclear Information System (INIS)
Burge, Scott R.; O'Hara, Matthew J.
2013-01-01
An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated system as an
General impact of robotics and automation in radiation environments
International Nuclear Information System (INIS)
Meghdari, A.; Salehi, M.
1993-01-01
Robotics and automation systems in nuclear environments require special design considerations. This paper presents an overview of selected robotic systems already designed and developed for use in nuclear applications at some U.S. laboratories. It will further emphasize on tasks identification, operational constraints, special considerations in materials selection, and a general guideline for robotic systems design in radiation environments. (author). 5 refs, 5 figs
Total Radiosynthesis: Thinking outside "the box".
Liang, Steven H; Vasdev, Neil
2015-09-01
. As with the vast majority of drugs, most radiotracers also fail, therefore expeditious evaluation of tracers in preclinical models prior to optimization or derivatization of the lead molecules/drugs is necessary. Furthermore the exact position of the 11 C and 18 F radionuclide in tracers is often critical for metabolic considerations, and flexible methodologies to introduce the radiolabel are needed. Using the principles of total synthesis our laboratory and others have shown that multi-step radiochemical reactions are indeed suitable for preclinical and even clinical use. As the goal of total synthesis is to be concise, we have also simplified the syntheses of radiopharmaceuticals. We are presently developing new strategies via [ 11 C]CO 2 fixation which has enabled library radiosynthesis as well as labeling non-activated arenes using [ 18 F]fluoride via iodonium ylides. Both of which have proven to be suitable for human PET imaging. We concurrently utilize state-of-the-art automation technologies including microfluidic flow chemistry and rapid purification strategies for radiopharmaceutical production. In this account we highlight how total radiosynthesis has impacted our radiochemistry program, with prominent examples from others, focusing on its impact towards preclinical and clinical research studies.
Automated drug dispensing system reduces medication errors in an intensive care setting.
Chapuis, Claire; Roustit, Matthieu; Bal, Gaëlle; Schwebel, Carole; Pansu, Pascal; David-Tchouda, Sandra; Foroni, Luc; Calop, Jean; Timsit, Jean-François; Allenet, Benoît; Bosson, Jean-Luc; Bedouch, Pierrick
2010-12-01
We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. Preintervention and postintervention study involving a control and an intervention medical intensive care unit. Two medical intensive care units in the same department of a 2,000-bed university hospital. Adult medical intensive care patients. After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; perror (20.4% and 13.5%; perror showed a significant impact of the automated dispensing system in reducing preparation errors (perrors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.
Automation and semantics: the CombeChem experience
Frey, Jeremy G.
2004-01-01
Some of the experiences of the CombeChem e-Science project in relation to both automation and the need for semantics in combining modern computer science techniques and chemistry are discussed. In particular the aspects of the smart laboratory, large scale data handling and the way this impacts on the necessary database technology are discussed. In addition some of the ways in which the grid can enable greater user interaction with services such as the National Crystallography Service and imp...
Cabrall, C.; Gomez, A.; Homola, J.; Hunt, S..; Martin, L.; Merccer, J.; Prevott, T.
2013-01-01
As part of an ongoing research effort on separation assurance and functional allocation in NextGen, a controller- in-the-loop study with ground-based automation was conducted at NASA Ames' Airspace Operations Laboratory in August 2012 to investigate the potential impact of introducing self-separating aircraft in progressively advanced NextGen timeframes. From this larger study, the current exploratory analysis of controller-automation interaction styles focuses on the last and most far-term time frame. Measurements were recorded that firstly verified the continued operational validity of this iteration of the ground-based functional allocation automation concept in forecast traffic densities up to 2x that of current day high altitude en-route sectors. Additionally, with greater levels of fully automated conflict detection and resolution as well as the introduction of intervention functionality, objective and subjective analyses showed a range of passive to active controller- automation interaction styles between the participants. Not only did the controllers work with the automation to meet their safety and capacity goals in the simulated future NextGen timeframe, they did so in different ways and with different attitudes of trust/use of the automation. Taken as a whole, the results showed that the prototyped controller-automation functional allocation framework was very flexible and successful overall.
DEFF Research Database (Denmark)
Pedersen, Natasja Wulff; Chandran, P. Anoop; Qian, Yu
2017-01-01
Manual analysis of flow cytometry data and subjective gate-border decisions taken by individuals continue to be a source of variation in the assessment of antigen-specific T cells when comparing data across laboratories, and also over time in individual labs. Therefore, strategies to provide...... automated analysis of major histocompatibility complex (MHC) multimer-binding T cells represent an attractive solution to decrease subjectivity and technical variation. The challenge of using an automated analysis approach is that MHC multimer-binding T cell populations are often rare and therefore...... laboratories. We used three different methods, FLOw Clustering without K (FLOCK), Scalable Weighted Iterative Flow-clustering Technique (SWIFT), and ReFlow to analyze flow cytometry data files from 28 laboratories. Each laboratory screened for antigen-responsive T cell populations with frequency ranging from 0...
Shop for quality or quantity? Volumes and costs in clinical laboratories.
Barletta, Giovanni; Zaninotto, Martina; Faggian, Diego; Plebani, Mario
2013-02-01
The increasing need to reduce the costs of providing diagnostic laboratory services has prompted initiatives based on the centralization and consolidation of laboratory facilities. However, the majority of papers and experiences reported in literature focus on "cost per test" thus overlooking the real value of a laboratory service, which requires more complex economic evaluations, such as cost-benefit, cost-effectiveness, and cost-utility analysis. It is important to perform cost analysis, which is no mean feat, by taking into consideration all variables affecting the final and true cost per test. The present study was conducted in order to evaluate the costs of delivering laboratory services in 20 Italian clinical laboratories using a widely accepted methodology, the so-called "activity-based costing analysis". The finding of a trend towards a decrease in total costs - due to an increase in test volumes - attained statistical significance only for quantities of up to about 1,100,00 tests per year. For 1,800,00 tests and more, the cost per test appeared to range from 1.5 to 2.0 € irrespective of the different volumes. Regarding the relationship between volumes and number of staff, there is an evident linear relationship between the number of senior staff and volumes, whereas this trend is not observed in the case of medical technologists, the degree and type of automation strongly affecting this variable. The findings made in the present study confirm that the relationship between volumes and costs is not linear; since it is complex, numerous variables should be taken into account.
AUTOMATED INADVERTENT INTRUDER APPLICATION
International Nuclear Information System (INIS)
Koffman, L; Patricia Lee, P; Jim Cook, J; Elmer Wilhite, E
2007-01-01
The Environmental Analysis and Performance Modeling group of Savannah River National Laboratory (SRNL) conducts performance assessments of the Savannah River Site (SRS) low-level waste facilities to meet the requirements of DOE Order 435.1. These performance assessments, which result in limits on the amounts of radiological substances that can be placed in the waste disposal facilities, consider numerous potential exposure pathways that could occur in the future. One set of exposure scenarios, known as inadvertent intruder analysis, considers the impact on hypothetical individuals who are assumed to inadvertently intrude onto the waste disposal site. Inadvertent intruder analysis considers three distinct scenarios for exposure referred to as the agriculture scenario, the resident scenario, and the post-drilling scenario. Each of these scenarios has specific exposure pathways that contribute to the overall dose for the scenario. For the inadvertent intruder analysis, the calculation of dose for the exposure pathways is a relatively straightforward algebraic calculation that utilizes dose conversion factors. Prior to 2004, these calculations were performed using an Excel spreadsheet. However, design checks of the spreadsheet calculations revealed that errors could be introduced inadvertently when copying spreadsheet formulas cell by cell and finding these errors was tedious and time consuming. This weakness led to the specification of functional requirements to create a software application that would automate the calculations for inadvertent intruder analysis using a controlled source of input parameters. This software application, named the Automated Inadvertent Intruder Application, has undergone rigorous testing of the internal calculations and meets software QA requirements. The Automated Inadvertent Intruder Application was intended to replace the previous spreadsheet analyses with an automated application that was verified to produce the same calculations and
Using historical wafermap data for automated yield analysis
International Nuclear Information System (INIS)
Tobin, K.W.; Karnowski, T.P.; Gleason, S.S.; Jensen, D.; Lakhani, F.
1999-01-01
To be productive and profitable in a modern semiconductor fabrication environment, large amounts of manufacturing data must be collected, analyzed, and maintained. This includes data collected from in- and off-line wafer inspection systems and from the process equipment itself. This data is increasingly being used to design new processes, control and maintain tools, and to provide the information needed for rapid yield learning and prediction. Because of increasing device complexity, the amount of data being generated is outstripping the yield engineer close-quote s ability to effectively monitor and correct unexpected trends and excursions. The 1997 SIA National Technology Roadmap for Semiconductors highlights a need to address these issues through open-quotes automated data reduction algorithms to source defects from multiple data sources and to reduce defect sourcing time.close quotes SEMATECH and the Oak Ridge National Laboratory have been developing new strategies and technologies for providing the yield engineer with higher levels of assisted data reduction for the purpose of automated yield analysis. In this article, we will discuss the current state of the art and trends in yield management automation. copyright 1999 American Vacuum Society
Semi-automated microwave assisted solid-phase peptide synthesis
DEFF Research Database (Denmark)
Pedersen, Søren Ljungberg
with microwaves for SPPS has gained in popularity as it for many syntheses has provided significant improvement in terms of speed, purity, and yields, maybe especially in the synthesis of long and "difficult" peptides. Thus, precise microwave heating has emerged as one new parameter for SPPS, in addition...... to coupling reagents, resins, solvents etc. We have previously reported on microwave heating to promote a range of solid-phase reactions in SPPS. Here we present a new, flexible semi-automated instrument for the application of precise microwave heating in solid-phase synthesis. It combines a slightly modified...... Biotage Initiator microwave instrument, which is available in many laboratories, with a modified semi-automated peptide synthesizer from MultiSynTech. A custom-made reaction vessel is placed permanently in the microwave oven, thus the reactor does not have to be moved between steps. Mixing is achieved...
A simple method for validation and verification of pipettes mounted on automated liquid handlers
DEFF Research Database (Denmark)
Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias G
2011-01-01
We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadru......We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared...... are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....
The use of automation with the new pneumatic irradiation facility of the ORNL HFIR
International Nuclear Information System (INIS)
Dyer, F.F.; Robinson, L.; Emery, J.F.
1988-01-01
The High Flux Isotope Reactor at Oak Ridge National Laboratory has two pneumatic irradiation systems: PT-1 installed in 1970 and PT-2 installed in 1987, which are used for neutron activation analysis. Both systems have been described in the literature. By means of a Gould programmable controller, considerable progress has been made in a cost-effective manner to operate and automate the features of the new facility. A neutron counter is an integral part of the new pneumatic tube, and all of the hardware is present to enable automated delayed neutron counting. Some automation of the old system has also been accomplished by the use of a Zymark general purpose programmable robot. This paper describes the automated features of both systems. The reactor has been shut down for safety evaluation since November 1986, so that no irradiations have been made in the new pneumatic tube
Ahmed, Zeeshan
2010-01-01
In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.
An Easily Assembled Laboratory Exercise in Computed Tomography
Mylott, Elliot; Klepetka, Ryan; Dunlap, Justin C.; Widenhorn, Ralf
2011-01-01
In this paper, we present a laboratory activity in computed tomography (CT) primarily composed of a photogate and a rotary motion sensor that can be assembled quickly and partially automates data collection and analysis. We use an enclosure made with a light filter that is largely opaque in the visible spectrum but mostly transparent to the near…
Feasibility study for computerized automation of EPA Region II Technical Support Branch
International Nuclear Information System (INIS)
Stephens, F.B.; Morris, W.F.; Barton, G.W. Jr.; Fisher, E.R.
1978-01-01
Three options are presented for automating the chemistry laboratories at the Surveillance and Analysis Division, Environmental Protection Agency , at Edison, New Jersey. The laboratory served New York State, New Jersey and Puerto Rico. Each option was found to be cost-effective. For two of the systems, existing EPA laboratory software would be used without (option 1) and with (option 2) data management. For the third system, laboratory and data functions would be implemented on a different computer (PDP-11) from those now installed. Option 2, the most favorable system, would make use of existing programs and data-management features now being developed; it would break even in 1.82 y and accumulate $373,928 in the five years after installation
Directory of Open Access Journals (Sweden)
Fatma Demet Ä°nce
2016-08-01
Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy
International Nuclear Information System (INIS)
Lee, Seung Min; Kim, Jong Hyun; Seong, Poong Hyun
2014-01-01
Highlights: • We propose an estimation method of the automation rate by taking the advantages of automation as the estimation measures. • We conduct the experiments to examine the validity of the suggested method. • The higher the cognitive automation rate is, the greater the decreased rate of the working time will be. • The usefulness of the suggested estimation method is proved by statistical analyses. - Abstract: Since automation was introduced in various industrial fields, the concept of the automation rate has been used to indicate the inclusion proportion of automation among all work processes or facilities. Expressions of the inclusion proportion of automation are predictable, as is the ability to express the degree of the enhancement of human performance. However, many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, this paper proposes a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs). Automation in NPPs can be divided into two types: system automation and cognitive automation. Some general descriptions and characteristics of each type of automation are provided, and the advantages of automation are investigated. The advantages of each type of automation are used as measures of the estimation method of the automation rate. One advantage was found to be a reduction in the number of tasks, and another was a reduction in human cognitive task loads. The system and the cognitive automation rate were proposed as quantitative measures by taking advantage of the aforementioned benefits. To quantify the required human cognitive task loads and thus suggest the cognitive automation rate, Conant’s information-theory-based model was applied. The validity of the suggested method, especially as regards the cognitive automation rate, was proven by conducting
Fishman, M.
1977-01-01
An automated method to determine both inorganic and organic forms of arsenic In water, water-suspended mixtures, and streambed materials Is described. Organic arsenic-containing compounds are decomposed by either ultraviolet radiation or by suHurlc acid-potassium persulfate digestion. The arsenic liberated, with Inorganic arsenic originally present, is reduced to arsine with sodium borohydrlde. The arable Is stripped from the solution with the aid of nitrogen and Is then decomposed In a tube furnace heated to 800 ??C which Is placed in the optical path of an atomic absorption spectrometer. Thirty samples per hour can be analyzed to levels of 1 ??g arsenic per liter.
Automated Calibration of Dosimeters for Diagnostic Radiology
International Nuclear Information System (INIS)
Romero Acosta, A.; Gutierrez Lores, S.
2015-01-01
Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)
Highly automated driving, secondary task performance, and driver state.
Merat, Natasha; Jamson, A Hamish; Lai, Frank C H; Carsten, Oliver
2012-10-01
A driving simulator study compared the effect of changes in workload on performance in manual and highly automated driving. Changes in driver state were also observed by examining variations in blink patterns. With the addition of a greater number of advanced driver assistance systems in vehicles, the driver's role is likely to alter in the future from an operator in manual driving to a supervisor of highly automated cars. Understanding the implications of such advancements on drivers and road safety is important. A total of 50 participants were recruited for this study and drove the simulator in both manual and highly automated mode. As well as comparing the effect of adjustments in driving-related workload on performance, the effect of a secondary Twenty Questions Task was also investigated. In the absence of the secondary task, drivers' response to critical incidents was similar in manual and highly automated driving conditions. The worst performance was observed when drivers were required to regain control of driving in the automated mode while distracted by the secondary task. Blink frequency patterns were more consistent for manual than automated driving but were generally suppressed during conditions of high workload. Highly automated driving did not have a deleterious effect on driver performance, when attention was not diverted to the distracting secondary task. As the number of systems implemented in cars increases, an understanding of the implications of such automation on drivers' situation awareness, workload, and ability to remain engaged with the driving task is important.
The Laboratory for Laser Energetics’ Hydrogen Isotope Separation System
Energy Technology Data Exchange (ETDEWEB)
Shmayda, W.T., E-mail: wshm@lle.rochester.edu; Wittman, M.D.; Earley, R.F.; Reid, J.L.; Redden, N.P.
2016-11-01
The University of Rochester’s Laboratory for Laser Energetics has commissioned a hydrogen Isotope Separation System (ISS). The ISS uses two columns—palladium on kieselguhr and molecular sieve—that act in a complementary manner to separate the hydrogen species by mass. The 4-sL per day throughput system is compact and has no moving parts. The columns and the attendant gas storage and handling subsystems are housed in a 0.8 -m{sup 3} glovebox. The glovebox uses a helium cover gas that is continuously processed to extract oxygen and water vapor that permeates through the glovebox gloves and any tritium that is released while attaching or detaching vessels to add feedstock to or drawing product from the system. The isotopic separation process is automated and does not require manual intervention. A total of 315 TBq of tritium was extracted from 23.6 sL of hydrogen with tritium purities reaching 99.5%. Deuterium was the sole residual component in the processed gas. Raffinate contained 0.2 TBq of activity was captured for reprocessing. The total emission from the system to the environment was 0.4 GBq over three weeks.
Trbusek, J
2009-11-01
Detection of HCV core antigen as direct marker of hepatitis C infection clearly improves diagnosis of this disease (especially reduction of window period) and brings broad clinical utilization. The company Abbott Laboratories offers fully automated laboratory test for measurement of HCV core antigen on ARCHITECT analyzers.
Fleischer, Heidi; Ramani, Kinjal; Blitti, Koffi; Roddelkopf, Thomas; Warkentin, Mareike; Behrend, Detlef; Thurow, Kerstin
2018-02-01
Automation systems are well established in industries and life science laboratories, especially in bioscreening and high-throughput applications. An increasing demand of automation solutions can be seen in the field of analytical measurement in chemical synthesis, quality control, and medical and pharmaceutical fields, as well as research and development. In this study, an automation solution was developed and optimized for the investigation of new biliary endoprostheses (stents), which should reduce clogging after implantation in the human body. The material inside the stents (incrustations) has to be controlled regularly and under identical conditions. The elemental composition is one criterion to be monitored in stent development. The manual procedure was transferred to an automated process including sample preparation, elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS), and data evaluation. Due to safety issues, microwave-assisted acid digestion was executed outside of the automation system. The performance of the automated process was determined and validated. The measurement results and the processing times were compared for both the manual and the automated procedure. Finally, real samples of stent incrustations and pig bile were analyzed using the automation system.
Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian
2017-09-01
This paper proposed a new reaction headspace gas chromatographic (HS-GC) method for efficiently quantifying the total starch content in wheat flours. A certain weight of wheat flour was oxidized by potassium dichromate in an acidic condition in a sealed headspace vial. The results show that the starch in wheat flour can be completely transferred to carbon dioxide at the given conditions (at 100 °C for 40 min) and the total starch content in wheat flour sample can be indirectly quantified by detecting the CO 2 formed from the oxidation reaction. The data showed that the relative standard deviation of the reaction HS-GC method in the precision test was less than 3.06%, and the relative differences between the new method and the reference method (titration method) were no more than 8.90%. The new reaction HS-GC method is automated, accurate, and can be a reliable tool for determining the total starch content in wheat flours in both laboratory and industrial applications. Graphical abstract The total starch content in wheat flour can be indirectly quantified by the GC detection of the CO 2 formed from the oxidation reaction between wheat flour and potassium dichromate in an acidic condition.
An automated solution enrichment system for uranium analysis
International Nuclear Information System (INIS)
Jones, S.A.; Sparks, R.; Sampson, T.; Parker, J.; Horley, E.; Kelly, T.
1993-01-01
An automated Solution Enrichment system (SES) for analysis of Uranium and U-235 isotopes in process samples has been developed through a joint effort between Los Alamos National Laboratory and Martin Marietta Energy systems, Portsmouth Gaseous Diffusion Plant. This device features an advanced robotics system which in conjuction with stabilized passive gamma-ray and X-ray fluorescence detectors provides for rapid, non-destructive analyses of process samples for improved special nuclear material accountability and process control
Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J
2015-01-01
The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use.
Automated reasoning applications to design validation and sneak function analysis
International Nuclear Information System (INIS)
Stratton, R.C.
1984-01-01
Argonne National Laboratory (ANL) is actively involved in the LMFBR Man-Machine Integration (MMI) Safety Program. The objective of this program is to enhance the operational safety and reliability of fast-breeder reactors by optimum integration of men and machines through the application of human factors principles and control engineering to the design, operation, and the control environment. ANL is developing methods to apply automated reasoning and computerization in the validation and sneak function analysis process. This project provides the element definitions and relations necessary for an automated reasoner (AR) to reason about design validation and sneak function analysis. This project also provides a demonstration of this AR application on an Experimental Breeder Reactor-II (EBR-II) system, the Argonne Cooling System
Automated Classification and Analysis of Non-metallic Inclusion Data Sets
Abdulsalam, Mohammad; Zhang, Tongsheng; Tan, Jia; Webler, Bryan A.
2018-05-01
The aim of this study is to utilize principal component analysis (PCA), clustering methods, and correlation analysis to condense and examine large, multivariate data sets produced from automated analysis of non-metallic inclusions. Non-metallic inclusions play a major role in defining the properties of steel and their examination has been greatly aided by automated analysis in scanning electron microscopes equipped with energy dispersive X-ray spectroscopy. The methods were applied to analyze inclusions on two sets of samples: two laboratory-scale samples and four industrial samples from a near-finished 4140 alloy steel components with varying machinability. The laboratory samples had well-defined inclusions chemistries, composed of MgO-Al2O3-CaO, spinel (MgO-Al2O3), and calcium aluminate inclusions. The industrial samples contained MnS inclusions as well as (Ca,Mn)S + calcium aluminate oxide inclusions. PCA could be used to reduce inclusion chemistry variables to a 2D plot, which revealed inclusion chemistry groupings in the samples. Clustering methods were used to automatically classify inclusion chemistry measurements into groups, i.e., no user-defined rules were required.
Wellinghausen, Nele; Dietenberger, Hanna
2011-08-01
Automated Treponema pallidum-specific chemi-luminescence immunoassays (CLIA) run on random-access analyzers allow for rapid diagnosis of syphilis infection. We evaluated the LIAISON Treponema Screen (LIA) and the ARCHITECT Syphilis TP (ARCH) in comparison to the Treponema pallidum particle agglutination (TPPA) test, as a screening test for syphilis. We performed a prospective study using 577 sera submitted for diagnosis of syphilis, including 318 samples from pregnant women. In addition, 42 stored sera from 32 patients with clinically and serologically characterized syphilis infection were investigated. In the prospective study, the sensitivity and specificity of LIA, ARCH, and TPPA were 100% (18/18), 100% (17/17), and 100% (18/18), and 100% (558/558), 99.8% (552/553), and 99.6% (556/558), respectively. In pregnant women, the specificity of LIA and ARCH was 100% (317/317) and of TPPA 99.7% (316/317). One sample from a child with assumed exposure to maternal antitreponemal antibodies was omitted from analysis. LIA, ARCH, and TPPA were also positive in all investigated sera from patients with known syphilis. Both automated CLIA demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis under routine conditions of a diagnostic laboratory. Thus, these may be used independently as an alternative to the manual TPPA screen.
International Nuclear Information System (INIS)
Moser, D.R.
1986-01-01
Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs
Directory of Open Access Journals (Sweden)
Chinmay A. Shukla
2017-05-01
Full Text Available The implementation of automation in the multistep flow synthesis is essential for transforming laboratory-scale chemistry into a reliable industrial process. In this review, we briefly introduce the role of automation based on its application in synthesis viz. auto sampling and inline monitoring, optimization and process control. Subsequently, we have critically reviewed a few multistep flow synthesis and suggested a possible control strategy to be implemented so that it helps to reliably transfer the laboratory-scale synthesis strategy to a pilot scale at its optimum conditions. Due to the vast literature in multistep synthesis, we have classified the literature and have identified the case studies based on few criteria viz. type of reaction, heating methods, processes involving in-line separation units, telescopic synthesis, processes involving in-line quenching and process with the smallest time scale of operation. This classification will cover the broader range in the multistep synthesis literature.
Automated system for calibration and control of the CHSPP-800 multichannel γ detector parameters
International Nuclear Information System (INIS)
Avvakumov, N.A.; Belikov, N.I.; Goncharenko, Yu.M.
1987-01-01
An automated system for adjustment, calibration and control of total absorption Cherenkov spectrometer is described. The system comprises a mechanical platform, capable of moving in two mutually perpendicular directions; movement detectors and limit switches; power unit, automation unit with remote control board. The automated system can operate both in manual control regime with coordinate control by a digital indicator, and in operation regime with computer according to special programs. The platform mounting accuracy is ± 0.1 mm. Application of the automated system has increased the rate of the course of the counter adjustment works 3-5 times
Automated Controlled-Potential Coulometer for the IAEA
International Nuclear Information System (INIS)
Cordaro, J.V.; Holland, M.K.; Fields, T.
1998-01-01
An automated controlled-potential coulometer has been developed at the Savannah River Site (SRS) for the determination of plutonium for use at the International Atomic Energy Agency's (IAEA) Safeguards Analytical Laboratory in Siebersdorf, Austria. The system is functionally the same as earlier systems built for use at the Savannah River Site's Analytical Laboratory. All electronic circuits and printed circuits boards have been upgraded with state-of-the-art components. A higher amperage potentiostat with improved control stability has been developed. The system achieves electronic calibration accuracy and linearity of better than 0.01 percent, with a precision and accuracy better than 0.1 percent has been demonstrated. This coulometer features electrical calibration of the integration system, electrolysis current background corrections, and control-potential adjustment capabilities. These capabilities allow application of the system to plutonium measurements without chemical standards, achieving traceability to the international measurement system through electrical standards and Faraday's constant. the chemist is provided with the capability to perform measurements without depending upon chemical standards, which is a significant advantage for applications such as characterization of primary and secondary standards. Additional benefits include reducing operating cost to procure, prepare and measure calibration standards and the corresponding decrease in radioactive waste generation. The design and documentation of the automated instrument are provided herein. Each individual module's operation, wiring, layout, and alignment are described. Interconnection of the modules and system calibration are discussed. A complete set of prints and a list of associated parts are included
Energy Technology Data Exchange (ETDEWEB)
Cristiano, Barbara F.G.; Delgado, Jose U.; Araujo, Radier M.S. de; Silva, Jose W.S. da; Barros, Pedro D. de, E-mail: barbara@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)
2009-07-01
Brazilian nuclear facilities, in accordance with the regulation CNEN-NN-2.02, must have available measurement systems which allow to determine their nuclear material inventories. For the evaluation and the follow up the performance of the involved laboratories in those measurement systems, the accomplishment of interlaboratory comparison programmes becomes fundamental. Therefore, the implementation of the potentiometric titration viewing the characterization of uranium samples, represents an reference element for the Brazilian programs
AuTom: a novel automatic platform for electron tomography reconstruction
Han, Renmin
2017-07-26
We have developed a software package towards automatic electron tomography (ET): Automatic Tomography (AuTom). The presented package has the following characteristics: accurate alignment modules for marker-free datasets containing substantial biological structures; fully automatic alignment modules for datasets with fiducial markers; wide coverage of reconstruction methods including a new iterative method based on the compressed-sensing theory that suppresses the “missing wedge” effect; and multi-platform acceleration solutions that support faster iterative algebraic reconstruction. AuTom aims to achieve fully automatic alignment and reconstruction for electron tomography and has already been successful for a variety of datasets. AuTom also offers user-friendly interface and auxiliary designs for file management and workflow management, in which fiducial marker-based datasets and marker-free datasets are addressed with totally different subprocesses. With all of these features, AuTom can serve as a convenient and effective tool for processing in electron tomography.
Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J
2015-04-01
The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Robotic control architecture development for automated nuclear material handling systems
International Nuclear Information System (INIS)
Merrill, R.D.; Hurd, R.; Couture, S.; Wilhelmsen, K.
1995-02-01
Lawrence Livermore National Laboratory (LLNL) is engaged in developing automated systems for handling materials for mixed waste treatment, nuclear pyrochemical processing, and weapon components disassembly. In support of these application areas there is an extensive robotic development program. This paper will describe the portion of this effort at LLNL devoted to control system architecture development, and review two applications currently being implemented which incorporate these technologies
Directory of Open Access Journals (Sweden)
Motasaddi Zarandy M
2007-07-01
Full Text Available Background: Hypothyroidism is a well-documented complication after treatment of laryngeal cancer and is particularly significant among patients undergoing laryngectomy. We investigated the frequency of hypothyroidism in patients treated with total laryngectomy for laryngeal cancer. We also evaluated the effect of neck radiotherapy on thyroid function after total laryngectomy for laryngeal cancer. Methods: In a cross-sectional study, we evaluated 31 patients with laryngeal squamous cell carcinoma (mean age 53.6 years. Among these patients, 14 were treated with surgery only and 17 were treated with surgery plus radiotherapy. Laboratory evaluation included levels of thyroid stimulating hormone (TSH, free T4, free T3, and antithyroid antibodies both preoperatively and postoperatively at the first day, as well as one and six months after surgery. Results: All patients had normal thyroid function before treatment; however, after 6 months, five patients (16.1% were hypothyroid. Of these, three patients (9.6% had subclinical symptoms, including elevated thyroid-stimulating hormone with normal free T4, and two patients (6.5% showed clinical symptoms of hypothyroidism. Radiotherapy and neck dissection were significantly associated with higher incidences of hypothyroidism. Conclusion: Our data suggest that hypothyroidism occurs in a substantial proportion of patients undergoing surgery for laryngeal cancer. The results indicate that thyroid function studies should be routinely performed in the follow-up care of laryngeal cancer patients, especially if radiotherapy and neck dissection were part of the treatment. We suggest that this approach will improve the patient's quality of life and diminish the co-morbidity associated with this kind of surgery.
Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L
2017-06-01
Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.
Directory of Open Access Journals (Sweden)
Ali Maleki
2015-12-01
Full Text Available Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC. To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use those data for quality control of obtaining results, to assist identification of complex and troublesome cases. Methods: During this descriptive analytic study, in addition to erythrocyte graphs from variety of patients, referring from March 2013 to Feb 2014 to our clinical laboratory, Zagros Hospital, Kermanshah, Iran, are given, the papers published in relevant literature as well as available published manuals of automatic blood cell counters were used. articles related to the key words of erythrocyte graphs and relevant literature as well as available published manuals of automatic blood cell counters were searched from valid databases such as Springer Link, google scholar, Pubmed and Sciencedirect. Then, the articles related to erythrogram, erythrocyte histogram and hematology analyzer graphs are involved in diagnosis of hematological disorder were searched and selected for this study. Results: Histograms and different automated CBC parameter become abnormal in various pathologic conditions, and can present important clues for diagnosis and treatment of hematologic and non-hematologic disorders. In several instances, these histograms have characteristic appearances in an exceedingly wide range of pathological conditions. In some hematologic disorders like iron deficiency or megaloblastic anemia, a sequential histogram can clearly show the progressive treatment and management. Conclusion: These graphical data are often accompanied by other automated CBC parameter and microscopic examination of peripheral blood smears (PBS, and can help in monitoring and
Niu, Jianwei; Geng, He; Zhang, Yijing; Du, Xiaoping
2018-09-01
Operator trust in automation is a crucial factor influencing its use and operational performance. However, the relationship between automation trust and performance remains poorly understood and requires further investigation. The objective of this paper is to explore the difference in trust and performance on automation-aided spacecraft rendezvous and docking (RVD) between the novice and the expert and to investigate the relationship between automation trust and performance as well. We employed a two-factor mixed design, with training skill (novice and expert) and automation mode (manual RVD and automation aided RVD) serving as the two factors. Twenty participants, 10 novices and 10 experts, were recruited to conduct six RVD tasks for two automation levels. After the tasks, operator performance was recorded by the desktop hand-held docking training equipment. Operator trust was also measured by a 12-items questionnaire at the beginning and end of each trial. As a result, automation narrowed the performance gap significantly between the novice and the expert, and the automation trust showed a marginally significant difference between the novice and the expert. Furthermore, the result demonstrated that the attitude angle control error of the expert was related to the total trust score, whereas other automation performance indicators were not related to the total score of trust. However, automation performance was related to the dimensions of trust, such as entrust, harmful, and dependable. Copyright © 2018 Elsevier Ltd. All rights reserved.
Validation of an automated system for aliquoting of HIV-1 Env-pseudotyped virus stocks.
Schultz, Anke; Germann, Anja; Fuss, Martina; Sarzotti-Kelsoe, Marcella; Ozaki, Daniel A; Montefiori, David C; Zimmermann, Heiko; von Briesen, Hagen
2018-01-01
The standardized assessments of HIV-specific immune responses are of main interest in the preclinical and clinical stage of HIV-1 vaccine development. In this regard, HIV-1 Env-pseudotyped viruses play a central role for the evaluation of neutralizing antibody profiles and are produced according to Good Clinical Laboratory Practice- (GCLP-) compliant manual and automated procedures. To further improve and complete the automated production cycle an automated system for aliquoting HIV-1 pseudovirus stocks has been implemented. The automation platform consists of a modified Tecan-based system including a robot platform for handling racks containing 48 cryovials, a Decapper, a tubing pump and a safety device consisting of ultrasound sensors for online liquid level detection of each individual cryovial. With the aim to aliquot the HIV-1 pseudoviruses in an automated manner under GCLP-compliant conditions a validation plan was developed where the acceptance criteria-accuracy, precision as well as the specificity and robustness-were defined and summarized. By passing the validation experiments described in this article the automated system for aliquoting has been successfully validated. This allows the standardized and operator independent distribution of small-scale and bulk amounts of HIV-1 pseudovirus stocks with a precise and reproducible outcome to support upcoming clinical vaccine trials.
Total plasma magnesium in healthy and critically ill foals.
Mariella, J; Isani, G; Andreani, G; Freccero, F; Carpenè, E; Castagnetti, C
2016-01-15
Abnormalities in total Mg (tMg) concentration in plasma and/or serum are common in critically ill humans, and the association with increased mortality has been documented in several clinical studies in adults and newborns with hypoxic-ischemic encephalopathy. Abnormalities in tMg were studied in hospitalized dogs, cats, and adult horses. Newborn foals were scarcely studied with regard to Mg concentration. The aims of the present study were: (1) to compare two analytical methods for the determination of tMg in plasma: the automated colorimetric method and the atomic absorption spectrometry; (2) to measure plasma tMg in healthy foals during the first 72 hours after birth and in sick foals during the first 72 hours of hospitalization; (3) to compare total plasma Mg concentration among healthy foals, foals affected by perinatal asphyxia syndrome (PAS), prematurity and/or dismaturity, and sepsis; (4) to evaluate tMg plasma concentration in surviving and non-surviving foals. One hundred seventeen foals were included in the study: 20 healthy and 97 sick foals. The automated method used in clinical practice probably overestimates plasma tMg. Due to its higher sensitivity and specificity, the atomic absorption spectrometry should be considered the method of choice from an analytical point of view, but requires an instrumentation not easily available in any laboratory and specific technical skills and competencies. Plasma tMg in healthy foals were included in the range 0.52 to 1.01 mmol/L and did not show any time-dependent change during the first 72 hours of life. In sick foals, tMg evaluated at T0 was statistically higher than tMg measured at subsequent times. Foals affected by PAS had a tMg at T0 significantly higher (P tMg measured at T0 in non-surviving than in surviving foals. Plasma tMg could be a useful parameter for the diagnosis of PAS and the formulation of the prognosis in critically ill foals. Copyright © 2016 Elsevier Inc. All rights reserved.
Automating radiochemistry: Considerations for commerical suppliers of devices
International Nuclear Information System (INIS)
Schmidt, D.G.
1993-01-01
The fundamental decision to automate a particular radiochemical synthesis for in house use depends primarily on the demand for the compound and the total number of studies to be carried out with that compound. For a commercial supplier of automated chemistry systems, much more goes in to the decision to design, develop and produce a particular automated chemistry system. There is a dramatic difference in design effort between an industrial environment and an academic environment. An in house system must be built only once and needs only to incrementally simplify the synthesis process. A commercial product must: have reasonable manufacturing costs; be easy to use; be aesthetically pleasing; be easy to install and service; be functionally integral with other equipment sold by the manufacturer; be marketable within the regulatory environment; address radiation safety issues. This paper discusses issues that guide commercial suppliers in the formation of their product lines
Shayanfar, Noushin; Tobler, Ulrich; von Eckardstein, Arnold; Bestmann, Lukas
2007-01-01
Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. A total of 332 specimens were collected and analyzed for insoluble urine components by microscopy and automated analyzers, namely the Iris iQ200 (Iris Diagnostics) and the UF-100 flow cytometer (Sysmex). The coefficients of variation for day-to-day quality control of the iQ200 and UF-100 analyzers were 6.5% and 5.5%, respectively, for red blood cells. We reached accuracy ranging from 68% (bacteria) to 97% (yeast) for the iQ200 and from 42% (bacteria) to 93% (yeast) for the UF-100. The combination of dipstick and automated urine sediment analysis increased the sensitivity of screening to approximately 98%. We conclude that automated urine sediment analysis is sufficiently precise and improves the workflow in a routine laboratory. In addition, it allows sediment analysis of all urine samples and thereby helps to detect pathological samples that would have been missed in the conventional two-step procedure according to the European guidelines. Although it is not a substitute for microscopic sediment examination, it can, when combined with dipstick testing, reduce the number of specimens submitted to microscopy. Visual microscopy is still required for some samples, namely, dysmorphic erythrocytes, yeasts, Trichomonas, oval fat bodies, differentiation of casts and certain crystals.
International Nuclear Information System (INIS)
Blair, D.S.; Morrison, D.J.
1997-01-01
The AQUASCAN, a commercially available, fully automated purge-and-trap gas chromatograph from Sentex Systems Inc., was implemented and evaluated as an in-field, automated monitoring system of contaminated groundwater at an active DOE remediation site in Pinellas, FL. Though the AQUASCAN is designed as a stand alone process analytical unit, implementation at this site required additional hardware. The hardware included a sample dilution system and a method for delivering standard solution to the gas chromatograph for automated calibration. As a result of the evaluation the system was determined to be a reliable and accurate instrument. The AQUASCAN reported concentration values for methylene chloride, trichloroethylene, and toluene in the Pinellas ground water were within 20% of reference laboratory values
International Nuclear Information System (INIS)
Ikeda, Eiji; Shiozaki, Kazumasa; Takahashi, Nobukazu; Togo, Takashi; Odawara, Toshinari; Oka, Takashi; Inoue, Tomio; Hirayasu, Yoshio
2008-01-01
The Mini-Mental State Examination (MMSE) is considered a useful supplementary method to diagnose dementia and evaluate the severity of cognitive disturbance. However, the region of the cerebrum that correlates with the MMSE score is not clear. Recently, a new method was developed to analyze regional cerebral blood flow (rCBF) using a Z score imaging system (eZIS). This system shows changes of rCBF when compared with a normal database. In addition, a three-dimensional stereotaxic region of interest (ROI) template (3DSRT), fully automated ROI analysis software was developed. The objective of this study was to investigate the correlation between rCBF changes and total MMSE score using these new methods. The association between total MMSE score and rCBF changes was investigated in 24 patients (mean age±standard deviation (SD) 71.5±9.2 years; 6 men and 18 women) with memory impairment using eZIS and 3DSRT. Step-wise multiple regression analysis was used for multivariate analysis, with the total MMSE score as the dependent variable and rCBF change in 24 areas as the independent variable. Total MMSE score was significantly correlated only with the reduction of left hippocampal perfusion but not with right (P<0.01). Total MMSE score is an important indicator of left hippocampal function. (author)
Total Radiosynthesis: Thinking outside “the box”
Liang, Steven H.; Vasdev, Neil
2016-01-01
. As with the vast majority of drugs, most radiotracers also fail, therefore expeditious evaluation of tracers in preclinical models prior to optimization or derivatization of the lead molecules/drugs is necessary. Furthermore the exact position of the 11C and 18F radionuclide in tracers is often critical for metabolic considerations, and flexible methodologies to introduce the radiolabel are needed. Using the principles of total synthesis our laboratory and others have shown that multi-step radiochemical reactions are indeed suitable for preclinical and even clinical use. As the goal of total synthesis is to be concise, we have also simplified the syntheses of radiopharmaceuticals. We are presently developing new strategies via [11C]CO2 fixation which has enabled library radiosynthesis as well as labeling non-activated arenes using [18F]fluoride via iodonium ylides. Both of which have proven to be suitable for human PET imaging. We concurrently utilize state-of-the-art automation technologies including microfluidic flow chemistry and rapid purification strategies for radiopharmaceutical production. In this account we highlight how total radiosynthesis has impacted our radiochemistry program, with prominent examples from others, focusing on its impact towards preclinical and clinical research studies. PMID:27512156
Laboratory cost and utilization containment.
Steiner, J W; Root, J M; White, D C
1991-01-01
The authors analyzed laboratory costs and utilization in 3,771 cases of Medicare inpatients admitted to a New England academic medical center ("the Hospital") from October 1, 1989 to September 30, 1990. The data were derived from the Hospital's Decision Resource System comprehensive data base. The authors established a historical reference point for laboratory costs as a percentage of total inpatient costs using 1981-82 Medicare claims data and cost report information. Inpatient laboratory costs were estimated at 9.5% of total inpatient costs for pre-Diagnostic Related Groups (DRGs) Medicare discharges. Using this reference point and adjusting for the Hospital's 1990 case mix, the "expected" laboratory cost was 9.3% of total cost. In fact, the cost averaged 11.5% (i.e., 24% above the expected cost level), and costs represented an even greater percentage of DRG reimbursement at 12.9%. If we regard the reimbursement as a total cost target (to eliminate losses from Medicare), then that 12.9% is 39% above the "expected" laboratory proportion of 9.3%. The Hospital lost an average of $1,091 on each DRG inpatient. The laboratory contributed 29% to this loss per case. Compared to other large hospitals, the Hospital was slightly (3%) above the mean direct cost per on-site test and significantly (58%) above the mean number of inpatient tests per inpatient day compared to large teaching hospitals. The findings suggest that careful laboratory cost analyses will become increasingly important as the proportion of patients reimbursed in a fixed manner grows. The future may hold a prospective zero-based laboratory budgeting process based on predictable patterns of DRG admissions or other fixed-reimbursement admission and laboratory utilization patterns.
Winterfield, Craig; van de Voort, F R
2014-12-01
The Fluid Life Corporation assessed and implemented Fourier transform infrared spectroscopy (FTIR)-based methods using American Society for Testing and Materials (ASTM)-like stoichiometric reactions for determination of acid and base number for in-service mineral-based oils. The basic protocols, quality control procedures, calibration, validation, and performance of these new quantitative methods are assessed. ASTM correspondence is attained using a mixed-mode calibration, using primary reference standards to anchor the calibration, supplemented by representative sample lubricants analyzed by ASTM procedures. A partial least squares calibration is devised by combining primary acid/base reference standards and representative samples, focusing on the main spectral stoichiometric response with chemometrics assisting in accounting for matrix variability. FTIR(AN/BN) methodology is precise, accurate, and free of most interference that affects ASTM D664 and D4739 results. Extensive side-by-side operational runs produced normally distributed differences with mean differences close to zero and standard deviations of 0.18 and 0.26 mg KOH/g, respectively. Statistically, the FTIR methods are a direct match to the ASTM methods, with superior performance in terms of analytical throughput, preparation time, and solvent use. FTIR(AN/BN) analysis is a viable, significant advance for in-service lubricant analysis, providing an economic means of trending samples instead of tedious and expensive conventional ASTM(AN/BN) procedures. © 2014 Society for Laboratory Automation and Screening.
Automation of cDNA Synthesis and Labelling Improves Reproducibility
Directory of Open Access Journals (Sweden)
Daniel Klevebring
2009-01-01
Full Text Available Background. Several technologies, such as in-depth sequencing and microarrays, enable large-scale interrogation of genomes and transcriptomes. In this study, we asses reproducibility and throughput by moving all laboratory procedures to a robotic workstation, capable of handling superparamagnetic beads. Here, we describe a fully automated procedure for cDNA synthesis and labelling for microarrays, where the purification steps prior to and after labelling are based on precipitation of DNA on carboxylic acid-coated paramagnetic beads. Results. The fully automated procedure allows for samples arrayed on a microtiter plate to be processed in parallel without manual intervention and ensuring high reproducibility. We compare our results to a manual sample preparation procedure and, in addition, use a comprehensive reference dataset to show that the protocol described performs better than similar manual procedures. Conclusions. We demonstrate, in an automated gene expression microarray experiment, a reduced variance between replicates, resulting in an increase in the statistical power to detect differentially expressed genes, thus allowing smaller differences between samples to be identified. This protocol can with minor modifications be used to create cDNA libraries for other applications such as in-depth analysis using next-generation sequencing technologies.
An automated smartphone-based diagnostic assay for point-of-care semen analysis
Kanakasabapathy, Manoj Kumar; Sadasivam, Magesh; Singh, Anupriya; Preston, Collin; Thirumalaraju, Prudhvi; Venkataraman, Maanasa; Bormann, Charles L.; Draz, Mohamed Shehata; Petrozza, John C.; Shafiee, Hadi
2017-01-01
Male infertility affects up to 12% of the world’s male population and is linked to various environmental and medical conditions. Manual microscope-based testing and computer-assisted semen analysis (CASA) are the current standard methods to diagnose male infertility; however, these methods are labor-intensive, expensive, and laboratory-based. Cultural and socially dominated stigma against male infertility testing hinders a large number of men from getting tested for infertility, especially in resource-limited African countries. We describe the development and clinical testing of an automated smartphone-based semen analyzer designed for quantitative measurement of sperm concentration and motility for point-of-care male infertility screening. Using a total of 350 clinical semen specimens at a fertility clinic, we have shown that our assay can analyze an unwashed, unprocessed liquefied semen sample with smartphone capabilities, can make remote semen quality testing accessible to people in both developed and developing countries who have access to smartphones. PMID:28330865
Quality Indicators for the Total Testing Process.
Plebani, Mario; Sciacovelli, Laura; Aita, Ada
2017-03-01
ISO 15189:2012 requires the use of quality indicators (QIs) to monitor and evaluate all steps of the total testing process, but several difficulties dissuade laboratories from effective and continuous use of QIs in routine practice. An International Federation of Clinical Chemistry and Laboratory Medicine working group addressed this problem and implemented a project to develop a model of QIs to be used in clinical laboratories worldwide to monitor and evaluate all steps of the total testing process, and decrease error rates and improve patient services in laboratory testing. All laboratories are invited, at no cost, to enroll in the project and contribute to harmonized management at the international level. Copyright © 2016 Elsevier Inc. All rights reserved.
Management issues in automated audit analysis
Energy Technology Data Exchange (ETDEWEB)
Jackson, K.A.; Hochberg, J.G.; Wilhelmy, S.K.; McClary, J.F.; Christoph, G.G.
1994-03-01
This paper discusses management issues associated with the design and implementation of an automated audit analysis system that we use to detect security events. It gives the viewpoint of a team directly responsible for developing and managing such a system. We use Los Alamos National Laboratory`s Network Anomaly Detection and Intrusion Reporter (NADIR) as a case in point. We examine issues encountered at Los Alamos, detail our solutions to them, and where appropriate suggest general solutions. After providing an introduction to NADIR, we explore four general management issues: cost-benefit questions, privacy considerations, legal issues, and system integrity. Our experiences are of general interest both to security professionals and to anyone who may wish to implement a similar system. While NADIR investigates security events, the methods used and the management issues are potentially applicable to a broad range of complex systems. These include those used to audit credit card transactions, medical care payments, and procurement systems.
The Rotary Zone Thermal Cycler: A Low-Power System Enabling Automated Rapid PCR
Bartsch, Michael S.; Renzi, Ronald F.; Van de Vreugde, James L.; Kim, Hanyoup; Knight, Daniel L.; Sinha, Anupama; Branda, Steven S.; Patel, Kamlesh D.
2015-01-01
Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling) to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis. PMID:25826708
The rotary zone thermal cycler: a low-power system enabling automated rapid PCR.
Directory of Open Access Journals (Sweden)
Michael S Bartsch
Full Text Available Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC, a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR amplification, and second strand cDNA synthesis.
Automation, communication and cybernetics in science and engineering 2013/2014
Isenhardt, Ingrid; Hees, Frank; Henning, Klaus
2014-01-01
This book continues the tradition of its predecessors “Automation, Communication and Cybernetics in Science and Engineering 2009/2010 and 2011/2012” and includes a representative selection of scientific publications from researchers at the institute cluster IMA/ZLW & IfU. IMA - Institute of Information Management in Mechanical Engineering ZLW - Center for Learning and Knowledge Management IfU - Associated Institute for Management Cybernetics e.V. Faculty of Mechanical Engineering, RWTH Aachen University The book presents a range of innovative fields of application, including: cognitive systems, cyber-physical production systems, robotics, automation technology, machine learning, natural language processing, data mining, predictive data analytics, visual analytics, innovation and diversity management, demographic models, virtual and remote laboratories, virtual and augmented realities, multimedia learning environments, organizational development and management cybernetics. The contributio...
Automated high-resolution NMR with a sample changer
International Nuclear Information System (INIS)
Wade, C.G.; Johnson, R.D.; Philson, S.B.; Strouse, J.; McEnroe, F.J.
1989-01-01
Within the past two years, it has become possible to obtain high-resolution NMR spectra using automated commercial instrumentation. Software control of all spectrometer functions has reduced most of the tedious manual operations to typing a few computer commands or even making selections from a menu. Addition of an automatic sample changer is the next natural step in improving efficiency and sample throughput; it has a significant (and even unexpected) impact on how NMR laboratories are run and how it is taught. Such an instrument makes even sophisticated experiments routine, so that people with no previous exposure to NMR can run these experiments after a training session of an hour or less. This A/C Interface examines the impact of such instrumentation on both the academic and the industrial laboratory
Automated metabolic gas analysis systems: a review.
Macfarlane, D J
2001-01-01
The use of automated metabolic gas analysis systems or metabolic measurement carts (MMC) in exercise studies is common throughout the industrialised world. They have become essential tools for diagnosing many hospital patients, especially those with cardiorespiratory disease. Moreover, the measurement of maximal oxygen uptake (VO2max) is routine for many athletes in fitness laboratories and has become a defacto standard in spite of its limitations. The development of metabolic carts has also facilitated the noninvasive determination of the lactate threshold and cardiac output, respiratory gas exchange kinetics, as well as studies of outdoor activities via small portable systems that often use telemetry. Although the fundamental principles behind the measurement of oxygen uptake (VO2) and carbon dioxide production (VCO2) have not changed, the techniques used have, and indeed, some have almost turned through a full circle. Early scientists often employed a manual Douglas bag method together with separate chemical analyses, but the need for faster and more efficient techniques fuelled the development of semi- and full-automated systems by private and commercial institutions. Yet, recently some scientists are returning back to the traditional Douglas bag or Tissot-spirometer methods, or are using less complex automated systems to not only save capital costs, but also to have greater control over the measurement process. Over the last 40 years, a considerable number of automated systems have been developed, with over a dozen commercial manufacturers producing in excess of 20 different automated systems. The validity and reliability of all these different systems is not well known, with relatively few independent studies having been published in this area. For comparative studies to be possible and to facilitate greater consistency of measurements in test-retest or longitudinal studies of individuals, further knowledge about the performance characteristics of these
International Nuclear Information System (INIS)
Guidicini, Olga M.; Olsen, Khris B.; Hembree, Doyle M.; Carter, Joel A.; Whitaker, Michael; Hayes, Susan M.
2005-01-01
In June 1998, the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC), with assistance from the U.S. Department of Energy (DOE), began a program to assess environmental sampling and analysis capabilities at laboratories in Argentina and Brazil. The program began with staff training conducted in South America and the United States by Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL). Both laboratories are participating members of DOE's Network of Analytical Laboratories (NWAL) that support IAEA's environmental sampling program. During the initial planning meeting, representatives from ABACC and all the participating analytical laboratories supporting ABACC were briefed on how the first exercise would be managed and on key aspects necessary to analyze low-level environmental samples for uranium. Subsequent to this training, a laboratory evaluation exercise (Exercise 1) was conducted using standard swipe samples prepared for this exercise by the International Atomic Energy Agency (IAEA). The results of Exercise 1 determined that sample contamination was a major factor in the analysis, and a thorough review of laboratory procedures was required to reduce the level of contamination to acceptable levels. Following modification of sample preparation procedures, the laboratories performed Exercise 2, an analysis of a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1547, Peach Leaves. The results of Exercise 2 demonstrated that several laboratories were capable of accurately determining the total uranium and uranium isotopic distribution in the peach leaves. To build on these successes, Exercise 3 was performed using a series of standard swipe samples prepared by the IAEA and distributed to laboratories supporting ABACC and to PNNL and ORNL. The results of Exercise 3 demonstrate that ABACC now has support laboratories in both Argentina and Brazil, which are capable of
Hawker, Charles D; McCarthy, William; Cleveland, David; Messinger, Bonnie L
2014-03-01
Mislabeled samples are a serious problem in most clinical laboratories. Published error rates range from 0.39/1000 to as high as 1.12%. Standardization of bar codes and label formats has not yet achieved the needed improvement. The mislabel rate in our laboratory, although low compared with published rates, prompted us to seek a solution to achieve zero errors. To reduce or eliminate our mislabeled samples, we invented an automated device using 4 cameras to photograph the outside of a sample tube. The system uses optical character recognition (OCR) to look for discrepancies between the patient name in our laboratory information system (LIS) vs the patient name on the customer label. All discrepancies detected by the system's software then require human inspection. The system was installed on our automated track and validated with production samples. We obtained 1 009 830 images during the validation period, and every image was reviewed. OCR passed approximately 75% of the samples, and no mislabeled samples were passed. The 25% failed by the system included 121 samples actually mislabeled by patient name and 148 samples with spelling discrepancies between the patient name on the customer label and the patient name in our LIS. Only 71 of the 121 mislabeled samples detected by OCR were found through our normal quality assurance process. We have invented an automated camera system that uses OCR technology to identify potential mislabeled samples. We have validated this system using samples transported on our automated track. Full implementation of this technology offers the possibility of zero mislabeled samples in the preanalytic stage.
Directory of Open Access Journals (Sweden)
Joel Krauser
Full Text Available Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using (14C or (3H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector.
Krauser, Joel; Walles, Markus; Wolf, Thierry; Graf, Daniel; Swart, Piet
2012-01-01
Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using 14C or 3H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector. PMID:22723932
Lean automation development : applying lean principles to the automation development process
Granlund, Anna; Wiktorsson, Magnus; Grahn, Sten; Friedler, Niklas
2014-01-01
By a broad empirical study it is indicated that automation development show potential of improvement. In the paper, 13 lean product development principles are contrasted to the automation development process and it is suggested why and how these principles can facilitate, support and improve the automation development process. The paper summarises a description of what characterises a lean automation development process and what consequences it entails. Main differences compared to current pr...
Energy Technology Data Exchange (ETDEWEB)
Gonder, Jeff; Wood, Eric; Lammert, Michael
2014-12-09
Jeff was invited to brief the EPA Mobile Sources Technical Review Subcommittee on considerations regarding potential energy and environmental considerations for connected and automated vehicles. For more information about the MSTRS see http://www2.epa.gov/caaac/mobile-sources-technical-review-subcommittee-mstrs-caaac.
Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.
1984-09-01
This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)
Completely automated modal analysis procedure based on the combination of different OMA methods
Ripamonti, Francesco; Bussini, Alberto; Resta, Ferruccio
2018-03-01
In this work a completely automated output-only Modal Analysis procedure is presented and all its benefits are listed. Based on the merging of different Operational Modal Analysis methods and a statistical approach, the identification process has been improved becoming more robust and giving as results only the real natural frequencies, damping ratios and mode shapes of the system. The effect of the temperature can be taken into account as well, leading to the creation of a better tool for automated Structural Health Monitoring. The algorithm has been developed and tested on a numerical model of a scaled three-story steel building present in the laboratories of Politecnico di Milano.
An audit of immunofixation requesting practices at a South African referral laboratory
Directory of Open Access Journals (Sweden)
Verena Gounden
2014-10-01
Objectives: To review the current process for IFE at IALCH in the context of reflective testing and to examine the use of the alpha-2-globulin/alpha-1-globulin ratio as a predictor of a positive IFE result. Methods: Data for 1260 consecutive SPEP tests performed at the IALCH National Health Laboratory Service were collected between February and July 2011. SPEP and IFE were performed with a Sebia Hydrasys automated electrophoresis system. The alpha-2-globulin/alpha-1-globulin ratio was calculated using density of corresponding fractions on SPEP. Results: Analysis revealed that of the 1260 SPEPs performed during the analysis period, 304 IFEs were suggested by the reviewing pathologist. A total of 45 (15% of the suggested IFEs were subsequently requested by the attending clinicians. Almost half (46.5% (n = 20 of the suggested IFEs that were performed revealed the presence of a paraprotein. There was no statistically-significant difference between the alpha-2-globulin/alpha-1-globulin ratio for patients with positive or negative IFEs (p-value = 0.2. Conclusions: This study reveals the need for reflective addition of IFE testing by the laboratory following suspicious findings on SPEP.
International Nuclear Information System (INIS)
Russell, J.A.G.; Alexoff, D.L.; Wolf, A.P.
1984-01-01
This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. 20 refs. (DT)
Trust in automation: integrating empirical evidence on factors that influence trust.
Hoff, Kevin Anthony; Bashir, Masooda
2015-05-01
We systematically review recent empirical research on factors that influence trust in automation to present a three-layered trust model that synthesizes existing knowledge. Much of the existing research on factors that guide human-automation interaction is centered around trust, a variable that often determines the willingness of human operators to rely on automation. Studies have utilized a variety of different automated systems in diverse experimental paradigms to identify factors that impact operators' trust. We performed a systematic review of empirical research on trust in automation from January 2002 to June 2013. Papers were deemed eligible only if they reported the results of a human-subjects experiment in which humans interacted with an automated system in order to achieve a goal. Additionally, a relationship between trust (or a trust-related behavior) and another variable had to be measured. All together, 101 total papers, containing 127 eligible studies, were included in the review. Our analysis revealed three layers of variability in human-automation trust (dispositional trust, situational trust, and learned trust), which we organize into a model. We propose design recommendations for creating trustworthy automation and identify environmental conditions that can affect the strength of the relationship between trust and reliance. Future research directions are also discussed for each layer of trust. Our three-layered trust model provides a new lens for conceptualizing the variability of trust in automation. Its structure can be applied to help guide future research and develop training interventions and design procedures that encourage appropriate trust. © 2014, Human Factors and Ergonomics Society.
Purcell, Royal
1988-01-01
Discusses the concept of a paperless society and the current situation in library automation. Various applications of automation and telecommunications are addressed, and future library automation is considered. Automation at the Monroe County Public Library in Bloomington, Indiana, is described as an example. (MES)
DB4US: A Decision Support System for Laboratory Information Management.
Carmona-Cejudo, José M; Hortas, Maria Luisa; Baena-García, Manuel; Lana-Linati, Jorge; González, Carlos; Redondo, Maximino; Morales-Bueno, Rafael
2012-11-14
Until recently, laboratory automation has focused primarily on improving hardware. Future advances are concentrated on intelligent software since laboratories performing clinical diagnostic testing require improved information systems to address their data processing needs. In this paper, we propose DB4US, an application that automates information related to laboratory quality indicators information. Currently, there is a lack of ready-to-use management quality measures. This application addresses this deficiency through the extraction, consolidation, statistical analysis, and visualization of data related to the use of demographics, reagents, and turn-around times. The design and implementation issues, as well as the technologies used for the implementation of this system, are discussed in this paper. To develop a general methodology that integrates the computation of ready-to-use management quality measures and a dashboard to easily analyze the overall performance of a laboratory, as well as automatically detect anomalies or errors. The novelty of our approach lies in the application of integrated web-based dashboards as an information management system in hospital laboratories. We propose a new methodology for laboratory information management based on the extraction, consolidation, statistical analysis, and visualization of data related to demographics, reagents, and turn-around times, offering a dashboard-like user web interface to the laboratory manager. The methodology comprises a unified data warehouse that stores and consolidates multidimensional data from different data sources. The methodology is illustrated through the implementation and validation of DB4US, a novel web application based on this methodology that constructs an interface to obtain ready-to-use indicators, and offers the possibility to drill down from high-level metrics to more detailed summaries. The offered indicators are calculated beforehand so that they are ready to use when the user
The Adam and Eve Robot Scientists for the Automated Discovery of Scientific Knowledge
King, Ross
A Robot Scientist is a physically implemented robotic system that applies techniques from artificial intelligence to execute cycles of automated scientific experimentation. A Robot Scientist can automatically execute cycles of hypothesis formation, selection of efficient experiments to discriminate between hypotheses, execution of experiments using laboratory automation equipment, and analysis of results. The motivation for developing Robot Scientists is to better understand science, and to make scientific research more efficient. The Robot Scientist `Adam' was the first machine to autonomously discover scientific knowledge: both form and experimentally confirm novel hypotheses. Adam worked in the domain of yeast functional genomics. The Robot Scientist `Eve' was originally developed to automate early-stage drug development, with specific application to neglected tropical disease such as malaria, African sleeping sickness, etc. We are now adapting Eve to work with on cancer. We are also teaching Eve to autonomously extract information from the scientific literature.
Automated Groundwater Screening
International Nuclear Information System (INIS)
Taylor, Glenn A.; Collard, Leonard B.
2005-01-01
The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application
DEFF Research Database (Denmark)
Baronaite, Renata; Engelhart, Merete; Mørk Hansen, Troels
2014-01-01
using IFA and automated EIA techniques. The IFA results generated by two independent laboratories were compared with the EIA results from antibodies against double-stranded DNA (dsDNA), from ANA screening, and from tests of the seven included subantigens. The final IFA and EIA results for 386 unique......, with Cohen's kappa value of 0.30 (95% confidence interval (CI) = 0.14-0.46), which decreased to 0.23 (95% CI = 0.06-0.40) when the results for dsDNA were omitted. The EIA method was less reliable for assessing nuclear and speckled reactivity patterns, whereas the IFA method presented difficulties detecting...... dsDNA and Ro activity. The automated EIA method was performed in a similar way to the conventional IFA method using HEp-2 cells; thus, automated EIA may be used as a screening test....
Directory of Open Access Journals (Sweden)
Marin Maria Angélica Bonadiman
2000-01-01
Full Text Available This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6 and high speed (30 readings/hour; it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.
Cost challenges for laboratory medicine automation in Africa
African Journals Online (AJOL)
cqq1a
2010-09-29
Sep 29, 2010 ... purification technology is noted in that the analysers do not resume function .... The other disadvantage is that if a particular element or reagent is of sub ... Sullivan (http://www.healthcare.frost.com) Stand-alone and Total Lab ...
Jumping into the 20th century before it is too late: is laboratory robotics still in its infancy?
Weinstein, D B; France, D S
1992-01-01
Successful management of laboratory robotic automation programmes in the environment of research and drug discovery within the pharmaceutical industry may perhaps be best compared to a chef preparing the perfect hollandaise sauce. All the ingredients must be available at the same time and be of highest quality for the right price. However, if components are not added in the right quantities and in the proper order, no amount of whipping together by the product champion will create the best product. In the past, managerial scepticism surrounding useful implementation of cost-effective, high-throughput robotic systems often placed these 'modern toys' at low priorities for research development laboratories. Management now recognizes the unique contributions of robotics in the research environment. Although the scientific director must still play the role of product champion, new questions are being proposed and new commitments are being made to bring the potential of robotic automation to every laboratory where repetitive functions can benefit from new applications. Research laboratory directors have become both the key ingredient, as well as the rate-limiting determinant in the development of new applications. Having fulfilled the promise of robotic automation to release talented personnel, the challenge now is for the 'end users', the bench scientists, to be provided with opportunities to invest the time and effort required for future applications and new career functions.
Use of remote systems and automation in radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Berger, J.D.; Gneiting, B.C.; Sanders, T.L.
1986-01-01
A cask handling technology development program is being pursued at the Hanford Engineering Development Laboratory in Richland, Washington and at Sandia National Laboratories in Albuquerque, New Mexico. This is part of the United States Department of Energy's program to enhance nuclear waste transportation technology. The goal of the effort is two-fold; first, to develop concepts that will reduce occupational exposures at shipping cask handling facilities within As Low As Reasonably Achievable (ALARA) objectives as directed by US DOE order (1), and second, to identify any design requirements for future cask development activities that comply with 'design for automation' goals
Characterizing the Laboratory Market
Energy Technology Data Exchange (ETDEWEB)
Shehabi, Arman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ganeshalingam, Mohan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); DeMates, Lauren [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mathew, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sartor, Dale [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
2017-04-11
Laboratories are estimated to be 3-5 times more energy intensive than typical office buildings and offer significant opportunities for energy use reductions. Although energy intensity varies widely, laboratories are generally energy intensive due to ventilation requirements, the research instruments used, and other health and safety concerns. Because the requirements of laboratory facilities differ so dramatically from those of other buildings, a clear need exists for an initiative exclusively targeting these facilities. The building stock of laboratories in the United States span different economic sectors, include governmental and academic institution, and are often defined differently by different groups. Information on laboratory buildings is often limited to a small subsection of the total building stock making aggregate estimates of the total U.S. laboratories and their energy use challenging. Previous estimates of U.S. laboratory space vary widely owing to differences in how laboratories are defined and categorized. A 2006 report on fume hoods provided an estimate of 150,000 laboratories populating the U.S. based in part on interviews of industry experts, however, a 2009 analysis of the 2003 Commercial Buildings Energy Consumption Survey (CBECS) generated an estimate of only 9,000 laboratory buildings. This report draws on multiple data sources that have been evaluated to construct an understanding of U.S. laboratories across different sizes and markets segments. This 2016 analysis is an update to draft reports released in October and December 2016.
He, Qingwen; Chen, Weiyuan; Huang, Liya; Lin, Qili; Zhang, Jingling; Liu, Rui; Li, Bin
2016-06-21
Carbapenem-resistant Enterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, one Klebsiella pneumoniae isolate produced both IMP-4 and NDM-1. One Klebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of
VALIDATING the Accuracy of Sighten's Automated Shading Tool
Energy Technology Data Exchange (ETDEWEB)
2018-05-04
Solar companies - including installers, financiers, and distributors - leverage Sighten software to deliver accurate shading calculations and solar proposals. Sighten recently partnered with Google Project Sunroof to provide automated remote shading analysis directly within the Sighten platform. The National Renewable Energy Laboratory (NREL), in partnership with Sighten, independently verified the accuracy of Sighten's remote-shading solar access values (SAVs) on an annual basis for locations in Los Angeles, California, and Denver, Colorado.
Caferra, Ricardo; Peltier, Nicholas
2004-01-01
This is the first book on automated model building, a discipline of automated deduction that is of growing importance Although models and their construction are important per se, automated model building has appeared as a natural enrichment of automated deduction, especially in the attempt to capture the human way of reasoning The book provides an historical overview of the field of automated deduction, and presents the foundations of different existing approaches to model construction, in particular those developed by the authors Finite and infinite model building techniques are presented The main emphasis is on calculi-based methods, and relevant practical results are provided The book is of interest to researchers and graduate students in computer science, computational logic and artificial intelligence It can also be used as a textbook in advanced undergraduate courses
Beating the heat! automated characterization of piezoelectric tubes for Starbugs
Piersiak, Rafal; Goodwin, Michael; Gilbert, James; Muller, Rolf
2014-08-01
The Australian Astronomical Observatory has extensively prototyped a new robotic positioner to allow simultaneous positioning of optical fibers at the focal plane called `Starbugs'. The Starbug devices each consist of two concentric piezoelectric tubes that `walk' the optical fiber over the focal plane to accuracy of several microns. Ongoing research has led to the development of several Starbug prototypes, but lack of performance data has hampered further progress in the design of the Starbug positioners and the support equipment required to power and control them. Furthermore, Starbugs have been selected for the TAIPAN instrument, a prototype for MANIFEST on the GMT. A need now arises to measure and characterize 100's of piezoelectric tubes before full scale production of Starbugs for TAIPAN. The manual measurements of these piezoelectric tubes are a time consuming process taking several hours. Therefore, a versatile automated system is needed to measure and characterize these tubes in the laboratory before production of Starbugs. We have solved this problem with the design of an automated LabVIEW application that significantly reduces test times to several minutes. We present the various design aspects of the automation system and provide analyses of example piezoelectric tubes for Starbugs.
[Morphometry of pulmonary tissue: From manual to high throughput automation].
Sallon, C; Soulet, D; Tremblay, Y
2017-12-01
Weibel's research has shown that any alteration of the pulmonary structure has effects on function. This demonstration required a quantitative analysis of lung structures called morphometry. This is possible thanks to stereology, a set of methods based on principles of geometry and statistics. His work has helped to better understand the morphological harmony of the lung, which is essential for its proper functioning. An imbalance leads to pathophysiology such as chronic obstructive pulmonary disease in adults and bronchopulmonary dysplasia in neonates. It is by studying this imbalance that new therapeutic approaches can be developed. These advances are achievable only through morphometric analytical methods, which are increasingly precise and focused, in particular thanks to the high-throughput automation of these methods. This review makes a comparison between an automated method that we developed in the laboratory and semi-manual methods of morphometric analyzes. The automation of morphometric measurements is a fundamental asset in the study of pulmonary pathophysiology because it is an assurance of robustness, reproducibility and speed. This tool will thus contribute significantly to the acceleration of the race for the development of new drugs. Copyright © 2017 SPLF. Published by Elsevier Masson SAS. All rights reserved.
DESIGN OF SMALL AUTOMATION WORK CELL SYSTEM DEMONSTRATIONS
International Nuclear Information System (INIS)
TURNER, C.; PEHL, J.
2000-01-01
Laboratory (LANL), which are considered to be representative of nuclear material handling glove box operations, the UTRRG has developed three task demonstration concepts to evaluate modular small automation systems. These demonstrations, utilizing 2 to 3 degree-of-freedom systems, include container movement, material transfer via pouring, and container loading. Based on an analysis of the ARIES pilot line specifications, these three simple demonstrations are considered to be similar to approximately 50% of the tasks in the ARIES pilot line. Since these task demonstrations functionally represent basic tasks, they are representative of the current potential of modular small automation technology to a wide spectrum of hazardous applications extending beyond the ARIES pilot line. The selection of these three demonstrations, their design and their effectiveness in demonstrating the potential of modular small automation technology are discussed
Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation
Croxatto, Antony; Dijkstra, Klaas; Prod'hom, Guy
2015-01-01
The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >106 bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >107 bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs. PMID:25972424
International Nuclear Information System (INIS)
Andersson, J.
2011-01-01
This study was conducted as a field study where control room operators and engineers from the refinery, heat and power, aviation, shipping and nuclear domain were interviewed regarding use of automation and the visualisation of automatic functions. The purpose of the study was to collect experiences and best practices from the five studied domains on levels of automation, function allocation and visualisation of automatic functions. In total, nine different control room settings were visited. The studied settings were compared using a systemic approach based on a human-machine systems model. The results show that the 'left over principle' is still the most common applied approach for function allocation but in high risk settings the decision whether to automate or not is more carefully considered. Regarding the visualisation of automatic functions, it was found that as long as each display type (process based, functional oriented, situation oriented and task based) are applied so that they correspond to the same level of abstraction as the technical system the operators mental model will be supported. No single display type can however readily match all levels of abstraction at the same time - all display types are still needed and serve different purposes. (Author)
Equipment development for automated assembly of solar modules
Hagerty, J. J.
1982-01-01
Prototype equipment was developed which allows for totally automated assembly in the three major areas of module manufacture: cell stringing, encapsulant layup and cure and edge sealing. The equipment is designed to be used in conjunction with a standard Unimate 2000B industrial robot although the design is adaptable to other transport systems.
Susrama, I. G.; Purnama, K. E.; Purnomo, M. H.
2016-01-01
Oligospermia is a male fertility issue defined as a low sperm concentration in the ejaculate. Normally the sperm concentration is 20-120 million/ml, while Oligospermia patients has sperm concentration less than 20 million/ml. Sperm test done in the fertility laboratory to determine oligospermia by checking fresh sperm according to WHO standards in 2010 [9]. The sperm seen in a microscope using a Neubauer improved counting chamber and manually count the number of sperm. In order to be counted automatically, this research made an automation system to analyse and count the sperm concentration called Automated Analysis of Sperm Concentration Counters (A2SC2) using Otsu threshold segmentation process and morphology. Data sperm used is the fresh sperm directly in the analysis in the laboratory from 10 people. The test results using A2SC2 method obtained an accuracy of 91%. Thus in this study, A2SC2 can be used to calculate the amount and concentration of sperm automatically
Human-Automation Allocations for Current Robotic Space Operations
Marquez, Jessica J.; Chang, Mai L.; Beard, Bettina L.; Kim, Yun Kyung; Karasinski, John A.
2018-01-01
gather existing lessons learned and best practices in these role assignments, from spaceflight operational experience of crew and ground teams that may be used to guide development for future systems. NASA and other space agencies have operational spaceflight experience with two key Human-Automation-Robotic (HAR) systems: heavy lift robotic arms and planetary robotic explorers. Additionally, NASA has invested in high-fidelity rover systems that can carry crew, building beyond Apollo's lunar rover. The heavy lift robotic arms reviewed are: Space Station Remote Manipulator System (SSRMS), Japanese Remote Manipulator System (JEMRMS), and the European Robotic Arm (ERA, designed but not deployed in space). The robotic rover systems reviewed are: Mars Exploration Rovers, Mars Science Laboratory rover, and the high-fidelity K10 rovers. Much of the design and operational feedback for these systems have been communicated to flight controllers and robotic design teams. As part of the mitigating the HARI risk for future human spaceflight operations, we must document function allocations between robots and humans that have worked well in practice.
The value of the Semantic Web in the laboratory.
Frey, Jeremy G
2009-06-01
The Semantic Web is beginning to impact on the wider chemical and physical sciences, beyond the earlier adopted bio-informatics. While useful in large-scale data driven science with automated processing, these technologies can also help integrate the work of smaller scale laboratories producing diverse data. The semantics aid the discovery, reliable re-use of data, provide improved provenance and facilitate automated processing by increased resilience to changes in presentation and reduced ambiguity. The Semantic Web, its tools and collections are not yet competitive with well-established solutions to current problems. It is in the reduced cost of instituting solutions to new problems that the versatility of Semantic Web-enabled data and resources will make their mark once the more general-purpose tools are more available.
Application of automated blind for daylighting in tropical region
International Nuclear Information System (INIS)
Chaiwiwatworakul, Pipat; Chirarattananon, Surapong; Rakkwamsuk, Pattana
2009-01-01
This paper reports an experimental and simulation study on application of automated Venetian blind for daylighting in tropical climate. A horizontal blind system operating automatically under programmed control was constructed and integrated onto the glazed windows to form a window system with an automated blind in a room of a laboratory building. A dimming controller was also integrated to the lighting system of the room. Different operation schemes of the window system were devised and tested in the attempt to maximize energy savings while maintaining the quality of the visual environment in the room. Intensive measurement of illuminance of the interior space was undertaken during the experiments. A methodology for calculation of interior daylight illuminance and associated glare corresponding to the configurations of the experiments was adopted. The method was coded into a computer program. Results of calculation from the program agree well with those from experiments for all the schemes of operation conducted. The program was used to simulate the situation when each scheme of operation was implemented for a whole year. It was found that such window system with automated blind enabled energy savings of 80%, but a more sophisticated scheme also helped maintain the interior visual quality at high level.
Development of automated welding process for field fabrication of thick walled pressure vessels
Energy Technology Data Exchange (ETDEWEB)
Schneider, U A
1981-01-01
Research on automatic welding processes for the fabrication of thick-walled pressure vessels continued. A literature review on the subject was completed. A laboratory study of criteria for judging acceptable root parameters continued. Equipment for a demonstration facility to test the components and processes of the automated welding system has been specified and is being obtained. (LCL)
Development of automated welding process for field fabrication of thick walled pressure vessels
International Nuclear Information System (INIS)
Schneider, U.A.
Research on automatic welding processes for the fabrication of thick-walled pressure vessels continued. A literature review on the subject was completed. A laboratory study of criteria for judging acceptable root parameters continued. Equipment for a demonstration facility to test the components and processes of the automated welding system has been specified and is being obtained
International Nuclear Information System (INIS)
Silva Junior, Iremar A.; Ramos, Marcio A.G.; Carvalho, Valdir S.; Diniz, Raphael E.; Cescon, Claudinei T.; Vivolo, Vitor; Potiens, Maria da Penha A.
2011-01-01
In order to improve the calibration process of portable detectors of the Instrument Calibration Laboratory of IPEN, an automated system to exchange the attenuators of the OB85/1 irradiator system was developed. This automation was developed following this sequence: (i) development of the device with the cooperation of the IPEN Sector of Projects, using the Solid Edge software to design the mechanical part of the exchanging device of the attenuators, in 3D; (ii) simulation with the Festo's FluidSim software to define the pneumatic components and their respective actuators; (iii) machining and assembly of mechanical parts; (iv) assembly of pneumatic components and their actuators, like magnetic pneumatic cylinders, which allow the use of magnetic sensors, used to confirm the attenuators opened or closed positions: actuators 5/2 each, with double solenoid; (v) assembly of the control panel for operating the device remotely from the operating room. With this automation, the technicians in charge of the detectors calibration and research testing will have no hand contact with lead attenuators, improving the calibration process due to the decrease in time spent with manual shift from the attenuators and avoiding accidents, like the fall of the lead attenuators. It has been a concern of the LCI-IPEN group the decrease in the time spent by the technicians in the calibration room controlled areas should follow the recommendations of the radiological protection rules, which recommend the shortest time possible of workers in these areas. Automated systems have, usually, a better rate of reproducibility, due to the small participation by the system operator, so the LCI-IPEN is following the trend of several laboratories and automating its processes. (author)
AuTom: a novel automatic platform for electron tomography reconstruction
Han, Renmin; Wan, Xiaohua; Wang, Zihao; Hao, Yu; Zhang, Jingrong; Chen, Yu; Gao, Xin; Liu, Zhiyong; Ren, Fei; Sun, Fei; Zhang, Fa
2017-01-01
-friendly interface and auxiliary designs for file management and workflow management, in which fiducial marker-based datasets and marker-free datasets are addressed with totally different subprocesses. With all of these features, AuTom can serve as a convenient
Long-term monitoring of soil gas fluxes with closed chambers using automated and manual systems
Energy Technology Data Exchange (ETDEWEB)
Scott, A.; Crichton, I.; Ball, B.C.
1999-10-01
The authors describe two gas sample collection techniques, each of which is used in conjunction with custom made automated or manually operated closed chambers. The automated system allows automatic collection of gas samples for simultaneous analysis of multiple trace gas efflux from soils, permitting long-term monitoring. Since the manual system is cheaper to produce, it can be replicated more than the automated and used to estimate spatial variability of soil fluxes. The automated chamber covers a soil area of 0.5 m{sup 2} and has a motor driven lid that remains operational throughout a range of weather conditions. Both systems use gas-tight containers of robust metal construction, which give good sample retention, thereby allowing long-term storage and convenience of transport from remote locations. The containers in the automated system are filled by pumping gas from the closed chamber via a multiway rotary valve. Stored samples from both systems are analyzed simultaneously for N{sub 2}O and CO{sub 2} using automated injection into laboratory-based gas chromatographs. The use of both collection systems is illustrated by results from a field experiment on sewage sludge disposal to land where N{sub 2}O fluxes were high. The automated gas sampling system permitted quantification of the marked temporal variability of concurrent N{sub 2}O and CO{sub 2} fluxes and allowed improved estimation of cumulative fluxes. The automated measurement approach yielded higher estimates of cumulative flux because integration of manual point-in-time observations missed a number of transient high-flux events.
International Nuclear Information System (INIS)
Yussup, N.; Azman, A.; Ibrahim, M.M.; Rahman, N.A.A.; Che Sohashaari, S.; Atan, M.N.; Hamzah, M.A.; Mokhtar, M.; Khalid, M.A.; Salim, N.A.A.; Hamzah, M.S.
2018-01-01
Neutron Activation Analysis (NAA) has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established from sample registration to analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, system automation is developed in order to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This report explains NAA process in Nuclear Malaysia and describes the automation development in detail which includes sample registration software, automatic sample changer system which consists of hardware and software; and sample analysis software. (author)
2013-08-29
... Customs Automation Program (NCAP) Tests Concerning Automated Commercial Environment (ACE) Document Image... National Customs Automation Program (NCAP) tests concerning document imaging, known as the Document Image... the National Customs Automation Program (NCAP) tests concerning document imaging, known as the...
Ramsahoi, L; Gao, A; Fabri, M; Odumeru, J A
2011-07-01
Automated electronic milk analyzers for rapid enumeration of total bacteria counts (TBC) are widely used for raw milk testing by many analytical laboratories worldwide. In Ontario, Canada, Bactoscan flow cytometry (BsnFC; Foss Electric, Hillerød, Denmark) is the official anchor method for TBC in raw cow milk. Penalties are levied at the BsnFC equivalent level of 50,000 cfu/mL, the standard plate count (SPC) regulatory limit. This study was conducted to assess the BsnFC for TBC in raw goat milk, to determine the mathematical relationship between the SPC and BsnFC methods, and to identify probable reasons for the difference in the SPC:BsnFC equivalents for goat and cow milks. Test procedures were conducted according to International Dairy Federation Bulletin guidelines. Approximately 115 farm bulk tank milk samples per month were tested for inhibitor residues, SPC, BsnFC, psychrotrophic bacteria count, composition (fat, protein, lactose, lactose and other solids, and freezing point), and somatic cell count from March 2009 to February 2010. Data analysis of the results for the samples tested indicated that the BsnFC method would be a good alternative to the SPC method, providing accurate and more precise results with a faster turnaround time. Although a linear regression model showed good correlation and prediction, tests for linearity indicated that the relationship was linear only beyond log 4.1 SPC. The logistic growth curve best modeled the relationship between the SPC and BsnFC for the entire sample population. The BsnFC equivalent to the SPC 50,000 cfu/mL regulatory limit was estimated to be 321,000 individual bacteria count (ibc)/mL. This estimate differs considerably from the BsnFC equivalent for cow milk (121,000 ibc/mL). Because of the low frequency of bulk tank milk pickups at goat farms, 78.5% of the samples had their oldest milking in the tank to be 6.5 to 9.0 d old when tested, compared with the cow milk samples, which had their oldest milking at 4 d
DEFF Research Database (Denmark)
Ejsing, Christer S.; Duchoslav, Eva; Sampaio, Julio
2006-01-01
We report a method for the identification and quantification of glycerophospholipid molecular species that is based on the simultaneous automated acquisition and processing of 41 precursor ion spectra, specific for acyl anions of common fatty acids moieties and several lipid class-specific fragment...... of glycerophospholipids. The automated analysis of total lipid extracts was powered by a robotic nanoflow ion source and produced currently the most detailed description of the glycerophospholipidome....
Nuclear power generation and automation technology
International Nuclear Information System (INIS)
Korei, Yoshiro
1985-01-01
The proportion of nuclear power in the total generated electric power has been increasing year after year, and the ensuring of its stable supply has been demanded. For the further development of nuclear power generation, the heightening of economical efficiency which is the largest merit of nuclear power and the public acceptance as a safe and stable electric power source are the important subjects. In order to solve these subjects, in nuclear power generation, various automation techniques have been applied for the purpose of the heightening of reliability, labor saving and the reduction of radiation exposure. Meeting the high needs of automation, the automation technology aided by computers have been applied to the design, manufacture and construction, operation and maintenance of nuclear power plants. Computer-aided design and the examples of design of a reactor building, pipings and a fuel assembly, an automatic welder for pipings of all position TIG welding type, a new central monitoring and control system, an automatic exchanger of control rod-driving mechanism, an automatic in-service inspection system for nozzles and pipings, and a robot for steam generator maintenance are shown. The trend of technical development and an intelligent moving robot, a system maintenance robot and a four legs walking robot are explained. (Kako, I.)
Pellikaan, W.F.; Hendriks, W.H.; Uwimanaa, G.; Bongers, L.J.G.M.; Becker, P.M.; Cone, J.W.
2011-01-01
An adaptation of fully automated gas production equipment was tested for its ability to simultaneously measure methane and total gas. The simultaneous measurement of gas production and gas composition was not possible using fully automated equipment, as the bottles should be kept closed during the
International Nuclear Information System (INIS)
Lee, Seung Min; Kim, Jong Hyun; Kim, Man Cheol; Seong, Poong Hyun
2016-01-01
Highlights: • We propose an appropriate automation rate that enables the best human performance. • We analyze the shortest working time considering Situation Awareness Recovery (SAR). • The optimized automation rate is estimated by integrating the automation and ostracism rate estimation methods. • The process to derive the optimized automation rate is demonstrated through case studies. - Abstract: Automation has been introduced in various industries, including the nuclear field, because it is commonly believed that automation promises greater efficiency, lower workloads, and fewer operator errors through reducing operator errors and enhancing operator and system performance. However, the excessive introduction of automation has deteriorated operator performance due to the side effects of automation, which are referred to as Out-of-the-Loop (OOTL), and this is critical issue that must be resolved. Thus, in order to determine the optimal level of automation introduction that assures the best human operator performance, a quantitative method of optimizing the automation is proposed in this paper. In order to propose the optimization method for determining appropriate automation levels that enable the best human performance, the automation rate and ostracism rate, which are estimation methods that quantitatively analyze the positive and negative effects of automation, respectively, are integrated. The integration was conducted in order to derive the shortest working time through considering the concept of situation awareness recovery (SAR), which states that the automation rate with the shortest working time assures the best human performance. The process to derive the optimized automation rate is demonstrated through an emergency operation scenario-based case study. In this case study, four types of procedures are assumed through redesigning the original emergency operating procedure according to the introduced automation and ostracism levels. Using the
An Automated Test Framework for Experimenting with Stochastic Behavior in Reconfigurable Logic
DEFF Research Database (Denmark)
Birklykke, Alex Aaen; Le Moullec, Yannick; Alminde, Lars
2012-01-01
In this paper, we present an automated test frame- work for the characterization of stochastic behavior in logic circuits. The framework is intended as a platform for experimenting with and providing statistics on digital architectures given behavioral uncertainties at the gate-level. As an exper......In this paper, we present an automated test frame- work for the characterization of stochastic behavior in logic circuits. The framework is intended as a platform for experimenting with and providing statistics on digital architectures given behavioral uncertainties at the gate...... block subject to voltage/frequency scaling and Vdd -noise. The framework provides easy interfacing with laboratory equipment, design of experiment capabilities and automatic test execution, thus providing a powerful tool for characterizing stochastic behavior in reconfigurable logic....
Automated extraction of radiation dose information from CT dose report images.
Li, Xinhua; Zhang, Da; Liu, Bob
2011-06-01
The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.
[Guidelines for blood transfusion teaching to medical laboratory technology students].
Moncharmont, P; Tourlourat, M; Fourcade, C; Julien, E; Peyrard, T; Cabaud, J-J
2012-02-01
The new French law about clinical laboratory medicine, the requirements of the ISO/CEI 15189 standard, the numerous abilities expected from the medical laboratory technologists and their involvement in blood bank management has led the working group "Recherche et démarche qualité" of the French Society of Blood Transfusion to initiate an inventory of blood transfusion teaching syllabus for medical laboratory technology students and to propose transfusion medicine teaching guidelines. Seven worksheets have been established for that purpose including red blood cell antigen typing and antibody screening, blood sampling in immunohaematology, automation, clinical practices, blood products, blood delivery and haemovigilance. These guidelines aim at contributing to the harmonization of transfusion medicine teaching and at providing objective elements to the medical laboratory managers regarding the practical and theoretical skills of theirs collaborators. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Determination of total phenolic amount of some edible fruits and ...
African Journals Online (AJOL)
STORAGESEVER
2009-06-17
Jun 17, 2009 ... cals in foods that help to counter the detrimental effects of reaction oxygen species ... vegetables. Hence, the present work was aimed at deter- minating the .... Total phenol analyses: Automation and. Comparison with Manual ...
The Cost-Effective Laboratory: Implementation of Economic Evaluation of Laboratory Testing
Directory of Open Access Journals (Sweden)
Bogavac-Stanojevic Natasa
2017-09-01
Full Text Available Laboratory testing as a part of laboratory in vitro diagnostic (IVD has become required tool in clinical practice for diagnosing, monitoring and prognosis of diseases, as well as for prediction of treatment response. The number of IVD tests available in laboratory practice has increased over the past decades and is likely to further increase in the future. Consequently, there is growing concern about the overutilization of laboratory tests and rising costs for laboratory testing. It is estimated that IVD accounts for between 1.4 and 2.3% of total healthcare expenditure and less than 5% of total hospital cost (Lewin Group report. These costs are rather low when compared to pharmaceuticals and medical aids which account for 15 and 5%, respectively. On the other hand, IVD tests play an important role in clinical practice, as they influence from 60% to 70% of clinical decision-making. Unfortunately, constant increases in healthcare spending are not directly related to healthcare benefit. Since healthcare resources are limited, health payers are interested whether the benefits of IVD tests are actually worth their cost. Many articles have introduced frameworks to assess the economic value of IVD tests. The most appropriate tool for quantitative assessment of their economic value is cost-effectiveness (CEA and cost-utility (CUA analysis. The both analysis determine cost in terms of effectiveness or utilities (combine quantity and quality of life of new laboratory test against its alternative. On the other hand, some investigators recommended calculation of laboratory test value as product of two ratios: Laboratory test value = (Technical accuracy/Turnaround time × (Utility/Costs. Recently, some researches used multicriteria decision analysis which allows comparison of diagnostic strategies in terms of benefits, opportunities, costs and risks. All analyses are constructed to identify laboratory test that produce the greatest healthcare benefit with
The Stanford Automated Mounter: Enabling High-Throughput Protein Crystal Screening at SSRL
International Nuclear Information System (INIS)
Smith, C.A.; Cohen, A.E.
2009-01-01
The macromolecular crystallography experiment lends itself perfectly to high-throughput technologies. The initial steps including the expression, purification, and crystallization of protein crystals, along with some of the later steps involving data processing and structure determination have all been automated to the point where some of the last remaining bottlenecks in the process have been crystal mounting, crystal screening, and data collection. At the Stanford Synchrotron Radiation Laboratory, a National User Facility that provides extremely brilliant X-ray photon beams for use in materials science, environmental science, and structural biology research, the incorporation of advanced robotics has enabled crystals to be screened in a true high-throughput fashion, thus dramatically accelerating the final steps. Up to 288 frozen crystals can be mounted by the beamline robot (the Stanford Auto-Mounting System) and screened for diffraction quality in a matter of hours without intervention. The best quality crystals can then be remounted for the collection of complete X-ray diffraction data sets. Furthermore, the entire screening and data collection experiment can be controlled from the experimenter's home laboratory by means of advanced software tools that enable network-based control of the highly automated beamlines.
Automation of Algorithmic Tasks for Virtual Laboratories Based on Automata Theory
Directory of Open Access Journals (Sweden)
Evgeniy A. Efimchik
2016-03-01
Full Text Available In the work a description of an automata model of standard algorithm for constructing a correct solution of algorithmic tests is given. The described model allows a formal determination of the variant complexity of algorithmic test and serves as a basis for determining the complexity functions, including the collision concept – the situation of uncertainty, when a choice must be made upon fulfilling the task between the alternatives with various priorities. The influence of collisions on the automata model and its inner structure is described. The model and complexity functions are applied for virtual laboratories upon designing the algorithms of constructing variant with a predetermined complexity in real time and algorithms of the estimation procedures of students’ solution with respect to collisions. The results of the work are applied to the development of virtual laboratories, which are used in the practical part of massive online course on graph theory.
World-wide distribution automation systems
International Nuclear Information System (INIS)
Devaney, T.M.
1994-01-01
A worldwide power distribution automation system is outlined. Distribution automation is defined and the status of utility automation is discussed. Other topics discussed include a distribution management system, substation feeder, and customer functions, potential benefits, automation costs, planning and engineering considerations, automation trends, databases, system operation, computer modeling of system, and distribution management systems
WIDAFELS flexible automation systems
International Nuclear Information System (INIS)
Shende, P.S.; Chander, K.P.; Ramadas, P.
1990-01-01
After discussing the various aspects of automation, some typical examples of various levels of automation are given. One of the examples is of automated production line for ceramic fuel pellets. (M.G.B.)
Automated-immunosensor with centrifugal fluid valves for salivary cortisol measurement
Directory of Open Access Journals (Sweden)
Masaki Yamaguchi
2014-08-01
Full Text Available Point-of-care measurement of the stress hormone cortisol will greatly facilitate the timely diagnosis and management of stress-related disorders. We describe an automated salivary cortisol immunosensor, incorporating centrifugal fluid valves and a disposable disc-chip that allows for truncated reporting of cortisol levels (<15 min. The performance characteristics of the immunosensor are optimized through select blocking agents to prevent the non-specific adsorption of proteins; immunoglobulin G (IgG polymer for the pad and milk protein for the reservoirs and the flow channels. Incorporated centrifugal fluid valves allow for rapid and repeat washings to remove impurities from the saliva samples. An optical reader and laptop computer automate the immunoassay processes and provide easily accessible digital readouts of salivary cortisol measurements. Linear regression analysis of the calibration curve for the cortisol immunosensor showed 0.92 of coefficient of multiple determination, R2, and 38.7% of coefficient of variation, CV, for a range of salivary cortisol concentrations between 0.4 and 11.3 ng/mL. The receiver operating characteristic (ROC curve analysis of human saliva samples indicate potential utility for discriminating stress disorders and underscore potential application of the biosensor in stress disorders. The performance of our salivary cortisol immunosensor approaches laboratory based tests and allows noninvasive, quantitative, and automated analysis of human salivary cortisol levels with reporting times compatible with point-of-care applications. Keywords: Immunosensor, Centrifugal fluid valve, Automation, Cortisol, Saliva
Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A
2006-11-01
Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.
Hoehl, Melanie M; Weißert, Michael; Dannenberg, Arne; Nesch, Thomas; Paust, Nils; von Stetten, Felix; Zengerle, Roland; Slocum, Alexander H; Steigert, Juergen
2014-06-01
This paper introduces a disposable battery-driven heating system for loop-mediated isothermal DNA amplification (LAMP) inside a centrifugally-driven DNA purification platform (LabTube). We demonstrate LabTube-based fully automated DNA purification of as low as 100 cell-equivalents of verotoxin-producing Escherichia coli (VTEC) in water, milk and apple juice in a laboratory centrifuge, followed by integrated and automated LAMP amplification with a reduction of hands-on time from 45 to 1 min. The heating system consists of two parallel SMD thick film resistors and a NTC as heating and temperature sensing elements. They are driven by a 3 V battery and controlled by a microcontroller. The LAMP reagents are stored in the elution chamber and the amplification starts immediately after the eluate is purged into the chamber. The LabTube, including a microcontroller-based heating system, demonstrates contamination-free and automated sample-to-answer nucleic acid testing within a laboratory centrifuge. The heating system can be easily parallelized within one LabTube and it is deployable for a variety of heating and electrical applications.
Automation of Test Cases for Web Applications : Automation of CRM Test Cases
Seyoum, Alazar
2012-01-01
The main theme of this project was to design a test automation framework for automating web related test cases. Automating test cases designed for testing a web interface provide a means of improving a software development process by shortening the testing phase in the software development life cycle. In this project an existing AutoTester framework and iMacros test automation tools were used. CRM Test Agent was developed to integrate AutoTester to iMacros and to enable the AutoTester,...
Steam generator automated eddy current data analysis: A benchmarking study. Final report
International Nuclear Information System (INIS)
Brown, S.D.
1998-12-01
The eddy current examination of steam generator tubes is a very demanding process. Challenges include: complex signal analysis, massive amount of data to be reviewed quickly with extreme precision and accuracy, shortages of data analysts during peak periods, and the desire to reduce examination costs. One method to address these challenges is by incorporating automation into the data analysis process. Specific advantages, which automated data analysis has the potential to provide, include the ability to analyze data more quickly, consistently and accurately than can be performed manually. Also, automated data analysis can potentially perform the data analysis function with significantly smaller levels of analyst staffing. Despite the clear advantages that an automated data analysis system has the potential to provide, no automated system has been produced and qualified that can perform all of the functions that utility engineers demand. This report investigates the current status of automated data analysis, both at the commercial and developmental level. A summary of the various commercial and developmental data analysis systems is provided which includes the signal processing methodologies used and, where available, the performance data obtained for each system. Also, included in this report is input from seventeen research organizations regarding the actions required and obstacles to be overcome in order to bring automatic data analysis from the laboratory into the field environment. In order to provide assistance with ongoing and future research efforts in the automated data analysis arena, the most promising approaches to signal processing are described in this report. These approaches include: wavelet applications, pattern recognition, template matching, expert systems, artificial neural networks, fuzzy logic, case based reasoning and genetic algorithms. Utility engineers and NDE researchers can use this information to assist in developing automated data
Sensors and Automated Analyzers for Radionuclides
International Nuclear Information System (INIS)
Grate, Jay W.; Egorov, Oleg B.; O'Hara, Matthew J.
2005-01-01
The production of nuclear weapons materials has generated a legacy of nuclear waste and contaminated environmental sites. (1) The remediation of radiochemically contaminated sites and processing of stored wastes into stable waste forms will require characterization procedures throughout all phases of these activities. (2) Consequently the demands for radiochemical analysis will increase rapidly in the future. Methods are required to do these analyses rapidly and precisely. To meet these characterization needs, new automated techniques are required in order to provide improved precision, consistent analytical protocols, reduced worker exposure to toxic and/or radioactive samples, greater sample throughput, reduced costs, and reduced secondary waste generation. Furthermore, methods are required that provide automatic analyses in settings other than analytical laboratories
Automation of reactor neutron activation analysis
International Nuclear Information System (INIS)
Pavlov, S.S.; Dmitriev, A.Yu.; Frontasyeva, M.V.
2013-01-01
The present status of the development of a software package designed for automation of NAA at the IBR-2 reactor of FLNP, JINR, Dubna, is reported. Following decisions adopted at the CRP Meeting in Delft, August 27-31, 2012, the missing tool - a sample changer - will be installed for NAA in compliance with the peculiar features of the radioanalytical laboratory REGATA at the IBR-2 reactor. The details of the design are presented. The software for operation with the sample changer consists of two parts. The first part is a user interface and the second one is a program to control the sample changer. The second part will be developed after installing the tool.
Stereo vision based automated grasp planning
International Nuclear Information System (INIS)
Wilhelmsen, K.; Huber, L.; Silva, D.; Grasz, E.; Cadapan, L.
1995-02-01
The Department of Energy has a need for treating existing nuclear waste. Hazardous waste stored in old warehouses needs to be sorted and treated to meet environmental regulations. Lawrence Livermore National Laboratory is currently experimenting with automated manipulations of unknown objects for sorting, treating, and detailed inspection. To accomplish these tasks, three existing technologies were expanded to meet the increasing requirements. First, a binocular vision range sensor was combined with a surface modeling system to make virtual images of unknown objects. Then, using the surface model information, stable grasp of the unknown shaped objects were planned algorithmically utilizing a limited set of robotic grippers. This paper is an expansion of previous work and will discuss the grasp planning algorithm
Chen, J H K; She, K K K; Kwong, T-C; Wong, O-Y; Siu, G K H; Leung, C-C; Chang, K-C; Tam, C-M; Ho, P-L; Cheng, V C C; Yuen, K-Y; Yam, W-C
2015-09-01
The automated high-throughput Abbott RealTime MTB real-time PCR assay has been recently launched for Mycobacterium tuberculosis complex (MTBC) clinical diagnosis. This study would like to evaluate its performance. We first compared its diagnostic performance with the Roche Cobas TaqMan MTB assay on 214 clinical respiratory specimens. Prospective analysis of a total 520 specimens was then performed to further evaluate the Abbott assay. The Abbott assay showed a lower limit of detection at 22.5 AFB/ml, which was more sensitive than the Cobas assay (167.5 AFB/ml). The two assays demonstrated a significant difference in diagnostic performance (McNemar's test; P = 0.0034), in which the Abbott assay presented significantly higher area under curve (AUC) than the Cobas assay (1.000 vs 0.880; P = 0.0002). The Abbott assay demonstrated extremely low PCR inhibition on clinical respiratory specimens. The automated Abbott assay required only very short manual handling time (0.5 h), which could help to improve the laboratory management. In the prospective analysis, the overall estimates for sensitivity and specificity of the Abbott assay were both 100 % among smear-positive specimens, whereas the smear-negative specimens were 96.7 and 96.1 %, respectively. No cross-reactivity with non-tuberculosis mycobacterial species was observed. The superiority in sensitivity of the Abbott assay for detecting MTBC in smear-negative specimens could further minimize the risk in MTBC false-negative detection. The new Abbott RealTime MTB assay has good diagnostic performance which can be a useful diagnostic tool for rapid MTBC detection in clinical laboratories.
Automating the SMAP Ground Data System to Support Lights-Out Operations
Sanders, Antonio
2014-01-01
The Soil Moisture Active Passive (SMAP) Mission is a first tier mission in NASA's Earth Science Decadal Survey. SMAP will provide a global mapping of soil moisture and its freeze/thaw states. This mapping will be used to enhance the understanding of processes that link the terrestrial water, energy, and carbon cycles, and to enhance weather and forecast capabilities. NASA's Jet Propulsion Laboratory has been selected as the lead center for the development and operation of SMAP. The Jet Propulsion Laboratory (JPL) has an extensive history of successful deep space exploration. JPL missions have typically been large scale Class A missions with significant budget and staffing. SMAP represents a new area of JPL focus towards low cost Earth science missions. Success in this new area requires changes to the way that JPL has traditionally provided the Mission Operations System (MOS)/Ground Data System (GDS) functions. The operation of SMAP requires more routine operations activities and support for higher data rates and data volumes than have been achieved in the past. These activities must be addressed by a reduced operations team and support staff. To meet this challenge, the SMAP ground data system provides automation that will perform unattended operations, including automated commanding of the SMAP spacecraft.
An Automation Planning Primer.
Paynter, Marion
1988-01-01
This brief planning guide for library automation incorporates needs assessment and evaluation of options to meet those needs. A bibliography of materials on automation planning and software reviews, library software directories, and library automation journals is included. (CLB)
Automation in Immunohematology
Directory of Open Access Journals (Sweden)
Meenu Bajpai
2012-01-01
Full Text Available There have been rapid technological advances in blood banking in South Asian region over the past decade with an increasing emphasis on quality and safety of blood products. The conventional test tube technique has given way to newer techniques such as column agglutination technique, solid phase red cell adherence assay, and erythrocyte-magnetized technique. These new technologies are adaptable to automation and major manufacturers in this field have come up with semi and fully automated equipments for immunohematology tests in the blood bank. Automation improves the objectivity and reproducibility of tests. It reduces human errors in patient identification and transcription errors. Documentation and traceability of tests, reagents and processes and archiving of results is another major advantage of automation. Shifting from manual methods to automation is a major undertaking for any transfusion service to provide quality patient care with lesser turnaround time for their ever increasing workload. This article discusses the various issues involved in the process.
International Nuclear Information System (INIS)
Mardis, E.R.; Roe, B.A.
1989-01-01
Automated procedures have been developed for both the simultaneous isolation of 96 single-stranded M13 chimeric template DNAs in less than two hours, and for simultaneously pipetting 24 dideoxynucleotide sequencing reactions on a commercially available laboratory workstation. The DNA sequencing results obtained by either radiolabeled or fluorescent methods are consistent with the premise that automation of these portions of DNA sequencing projects will improve the reproducibility of the DNA isolation and the procedures for these normally labor-intensive steps provides an approach for rapid acquisition of large amounts of high quality, reproducible DNA sequence data
Directory of Open Access Journals (Sweden)
Ibrahim Elsohaby
Full Text Available The objective of this study was to develop and compare the performance of laboratory grade and portable attenuated total reflectance infrared (ATR-IR spectroscopic approaches in combination with partial least squares regression (PLSR for the rapid quantification of alpaca serum IgG concentration, and the identification of low IgG (<1000 mg/dL, which is consistent with the diagnosis of failure of transfer of passive immunity (FTPI in neonates. Serum samples (n = 175 collected from privately owned, healthy alpacas were tested by the reference method of radial immunodiffusion (RID assay, and laboratory grade and portable ATR-IR spectrometers. Various pre-processing strategies were applied to the ATR-IR spectra that were linked to corresponding RID-IgG concentrations, and then randomly split into two sets: calibration (training and test sets. PLSR was applied to the calibration set and calibration models were developed, and the test set was used to assess the accuracy of the analytical method. For the test set, the Pearson correlation coefficients between the IgG measured by RID and predicted by both laboratory grade and portable ATR-IR spectrometers was 0.91. The average differences between reference serum IgG concentrations and the two IR-based methods were 120.5 mg/dL and 71 mg/dL for the laboratory and portable ATR-IR-based assays, respectively. Adopting an IgG concentration <1000 mg/dL as the cut-point for FTPI cases, the sensitivity, specificity, and accuracy for identifying serum samples below this cut point by laboratory ATR-IR assay were 86, 100 and 98%, respectively (within the entire data set. Corresponding values for the portable ATR-IR assay were 95, 99 and 99%, respectively. These results suggest that the two different ATR-IR assays performed similarly for rapid qualitative evaluation of alpaca serum IgG and for diagnosis of IgG <1000 mg/dL, the portable ATR-IR spectrometer performed slightly better, and provides more flexibility for
Patton, Charles J.; Kryskalla, Jennifer R.
2011-01-01
This report documents work at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) to validate enzymatic reduction, colorimetric determinative methods for nitrate + nitrite in filtered water by automated discrete analysis. In these standard- and low-level methods (USGS I-2547-11 and I-2548-11), nitrate is reduced to nitrite with nontoxic, soluble nitrate reductase rather than toxic, granular, copperized cadmium used in the longstanding USGS automated continuous-flow analyzer methods I-2545-90 (NWQL laboratory code 1975) and I-2546-91 (NWQL laboratory code 1979). Colorimetric reagents used to determine resulting nitrite in aforementioned enzymatic- and cadmium-reduction methods are identical. The enzyme used in these discrete analyzer methods, designated AtNaR2 by its manufacturer, is produced by recombinant expression of the nitrate reductase gene from wall cress (Arabidopsis thaliana) in the yeast Pichia pastoris. Unlike other commercially available nitrate reductases we evaluated, AtNaR2 maintains high activity at 37°C and is not inhibited by high-phenolic-content humic acids at reaction temperatures in the range of 20°C to 37°C. These previously unrecognized AtNaR2 characteristics are essential for successful performance of discrete analyzer nitrate + nitrite assays (henceforth, DA-AtNaR2) described here.
Automated systems to identify relevant documents in product risk management
2012-01-01
Background Product risk management involves critical assessment of the risks and benefits of health products circulating in the market. One of the important sources of safety information is the primary literature, especially for newer products which regulatory authorities have relatively little experience with. Although the primary literature provides vast and diverse information, only a small proportion of which is useful for product risk assessment work. Hence, the aim of this study is to explore the possibility of using text mining to automate the identification of useful articles, which will reduce the time taken for literature search and hence improving work efficiency. In this study, term-frequency inverse document-frequency values were computed for predictors extracted from the titles and abstracts of articles related to three tumour necrosis factors-alpha blockers. A general automated system was developed using only general predictors and was tested for its generalizability using articles related to four other drug classes. Several specific automated systems were developed using both general and specific predictors and training sets of different sizes in order to determine the minimum number of articles required for developing such systems. Results The general automated system had an area under the curve value of 0.731 and was able to rank 34.6% and 46.2% of the total number of 'useful' articles among the first 10% and 20% of the articles presented to the evaluators when tested on the generalizability set. However, its use may be limited by the subjective definition of useful articles. For the specific automated system, it was found that only 20 articles were required to develop a specific automated system with a prediction performance (AUC 0.748) that was better than that of general automated system. Conclusions Specific automated systems can be developed rapidly and avoid problems caused by subjective definition of useful articles. Thus the efficiency of
Department of Transportation — The Automated Budget System (ABS) automates management and planning of the Mike Monroney Aeronautical Center (MMAC) budget by providing enhanced capability to plan,...
Ball, Oliver; Robinson, Sarah; Bure, Kim; Brindley, David A; Mccall, David
2018-04-01
Phacilitate held a Special Interest Group workshop event in Edinburgh, UK, in May 2017. The event brought together leading stakeholders in the cell therapy bioprocessing field to identify present and future challenges and propose potential solutions to automation in cell therapy bioprocessing. Here, we review and summarize discussions from the event. Deep biological understanding of a product, its mechanism of action and indication pathogenesis underpin many factors relating to bioprocessing and automation. To fully exploit the opportunities of bioprocess automation, therapeutics developers must closely consider whether an automation strategy is applicable, how to design an 'automatable' bioprocess and how to implement process modifications with minimal disruption. Major decisions around bioprocess automation strategy should involve all relevant stakeholders; communication between technical and business strategy decision-makers is of particular importance. Developers should leverage automation to implement in-process testing, in turn applicable to process optimization, quality assurance (QA)/ quality control (QC), batch failure control, adaptive manufacturing and regulatory demands, but a lack of precedent and technical opportunities can complicate such efforts. Sparse standardization across product characterization, hardware components and software platforms is perceived to complicate efforts to implement automation. The use of advanced algorithmic approaches such as machine learning may have application to bioprocess and supply chain optimization. Automation can substantially de-risk the wider supply chain, including tracking and traceability, cryopreservation and thawing and logistics. The regulatory implications of automation are currently unclear because few hardware options exist and novel solutions require case-by-case validation, but automation can present attractive regulatory incentives. Copyright © 2018 International Society for Cellular Therapy
DEFF Research Database (Denmark)
van der Heijden, Suzanne; de Oliveira, Susanne Juel; Kampmann, Marie-Louise
2017-01-01
to compare different AmpliSeq™ workflows to investigate the possibility of using automated library building in forensic genetic case work. In order to do so, the SNP typing of the Somalis was performed using three different workflows: 1) manual library building and sequencing on the Ion PGM™, 2) automated...... workflows. The Biomek(®)3000/Ion PGM™ workflow was found to perform similarly to the manual/Ion PGM™ workflow. This argues for the use of automated library building in forensic genetic case work. Automated library building decreases the workload of the laboratory staff, decreases the risk of pipetting...... library building using the Biomek(®)3000 and sequencing on the Ion PGM™, and 3) automated library building using the Ion Chef™ and sequencing on the Ion S5™. AmpliSeq™ workflows were compared based on coverage, locus balance, noise, and heterozygote balance. Overall, the Ion Chef™/Ion S5™ workflow...
Tulip, Jennifer; Zimmermann, Jonas B; Farningham, David; Jackson, Andrew
2017-06-15
Behavioural training through positive reinforcement techniques is a well-recognised refinement to laboratory animal welfare. Behavioural neuroscience research requires subjects to be trained to perform repetitions of specific behaviours for food/fluid reward. Some animals fail to perform at a sufficient level, limiting the amount of data that can be collected and increasing the number of animals required for each study. We have implemented automated positive reinforcement training systems (comprising a button press task with variable levels of difficulty using LED cues and a fluid reward) at the breeding facility and research facility, to compare performance across these different settings, to pre-screen animals for selection and refine training protocols. Animals learned 1- and 4-choice button tasks within weeks of home enclosure training, with some inter-individual differences. High performance levels (∼200-300 trials per 60min session at ∼80% correct) were obtained without food or fluid restriction. Moreover, training quickly transferred to a laboratory version of the task. Animals that acquired the task at the breeding facility subsequently performed better both in early home enclosure sessions upon arrival at the research facility, and also in laboratory sessions. Automated systems at the breeding facility may be used to pre-screen animals for suitability for behavioural neuroscience research. In combination with conventional training, both the breeding and research facility systems facilitate acquisition and transference of learning. Automated systems have the potential to refine training protocols and minimise requirements for food/fluid control. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Zwaenepoel, Karen; Merkle, Dennis; Cabillic, Florian; Berg, Erica; Belaud-Rotureau, Marc-Antoine; Grazioli, Vittorio; Herelle, Olga; Hummel, Michael; Le Calve, Michele; Lenze, Dido; Mende, Stefanie; Pauwels, Patrick; Quilichini, Benoit; Repetti, Elena
2015-02-01
In the past several years we have observed a significant increase in our understanding of molecular mechanisms that drive lung cancer. Specifically in the non-small cell lung cancer sub-types, ALK gene rearrangements represent a sub-group of tumors that are targetable by the tyrosine kinase inhibitor Crizotinib, resulting in significant reductions in tumor burden. Phase II and III clinical trials were performed using an ALK break-apart FISH probe kit, making FISH the gold standard for identifying ALK rearrangements in patients. FISH is often considered a labor and cost intensive molecular technique, and in this study we aimed to demonstrate feasibility for automation of ALK FISH testing, to improve laboratory workflow and ease of testing. This involved automation of the pre-treatment steps of the ALK assay using various protocols on the VP 2000 instrument, and facilitating automated scanning of the fluorescent FISH specimens for simplified enumeration on various backend scanning and analysis systems. The results indicated that ALK FISH can be automated. Significantly, both the Ikoniscope and BioView system of automated FISH scanning and analysis systems provided a robust analysis algorithm to define ALK rearrangements. In addition, the BioView system facilitated consultation of difficult cases via the internet. Copyright © 2015 Elsevier Inc. All rights reserved.