WorldWideScience

Sample records for total knee implants

  1. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    Science.gov (United States)

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Poorer survival after a primary implant during revision total knee arthroplasty

    NARCIS (Netherlands)

    Meijer, Marrigje F.; Reininga, Inge H. F.; Boerboom, Alexander L.; Stevens, Martin; Bulstra, Sjoerd K.

    Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA. A retrospective

  3. Total knee arthroplasty

    DEFF Research Database (Denmark)

    Schrøder, Henrik M.; Petersen, Michael M.

    2016-01-01

    Total knee arthroplasty (TKA) is a successful treatment of the osteoarthritic knee, which has increased dramatically over the last 30 years. The indication is a painful osteoarthritic knee with relevant radiographic findings and failure of conservative measures like painkillers and exercise...... surgeon seems to positively influence the rate of surgical complications and implant survival. The painful TKA knee should be thoroughly evaluated, but not revised except if a relevant indication can be established. The most frequent indications for revision are: aseptic loosening, instability, infection...

  4. Total knee arthroplasty for severe valgus knee deformity.

    Science.gov (United States)

    Zhou, Xinhua; Wang, Min; Liu, Chao; Zhang, Liang; Zhou, Yixin

    2014-01-01

    Primary total knee arthroplasty (TKA) in severe valgus knees may prove challenging, and choice of implant depends on the severity of the valgus deformity and the extent of soft-tissue release. The purpose of this study was to review 8 to 11 years (mean, 10 years) follow-up results of primary TKA for varient-III valgus knee deformity with use of different type implants. Between January 2002 and January 2005, 20 women and 12 men, aged 47 to 63 (mean, 57.19 ± 6.08) years old, with varient-III valgus knees underwent primary TKA. Of the 32 patients, 37 knees had varient-III deformities. Pie crusting was carefully performed with small, multiple inside-out incisions, bone resection balanced the knee in lieu of soft tissue releases that were not used in the series. Cruciate-retaining knees (Gemini MKII, Link Company, Germany) were used in 13 knees, Genesis II (Simth & Nephew Company, USA) in 14 knees, and hinged knee (Endo-Model Company, Germany) in 10 knees. In five patients with bilateral variant-III TKAs, three patients underwent 1-stage bilateral procedures, and two underwent 2-stage procedures. All implants were cemented and the patella was not resurfaced. The Hospital for Special Surgery (HSS) knee score was assessed. Patients were followed up from 8 to 11 years. The mean HSS knee score were improved from 50.33 ± 11.60 to 90.06 ± 3.07 (P managed with rivaroxaban and thrombo-embolic deterrent stockings. There was no incidence of pulmonary embolism. Post-operative patient satisfaction was 80.7 ± 10.4 points in the groups. Prosthetic survival rate was 100% at mean 10 years postoperative. Not only hinged implants can be successfully used in variant-III valgus knees. As our results show, if proper ligament balancing techniques are used and proper ligament balance is attained, the knee may not require the use of a more constrained components. Our results also present alternative implant choices for severe knee deformities.

  5. Computer-navigated minimally invasive total knee arthroplasty for patients with retained implants in the femur

    Directory of Open Access Journals (Sweden)

    Sung-Yen Lin

    2014-08-01

    Full Text Available Total knee arthroplasty (TKA in patients with knee arthritis and retained implants in the ipsilateral femur is a challenge for knee surgeons. Use of a conventional intramedullary femoral cutting guide is not practical because of the obstruction of the medullary canal by implants. Previous studies have shown that computer-assisted surgery (CAS can help restore alignment in conventional TKA for patients with knee arthritis with retained femoral implants or extra-articular deformity, without the need for implant removal or osteotomy. However, little has been published regarding outcomes with the use of navigation in minimally invasive surgery (MIS-TKA for patients with this complex knee arthritis. MIS has been proven to provide less postoperative pain and faster recovery than conventional TKA, but MIS-TKA in patients with retained femoral implants poses a greater risk in limb malalignment. The purpose of this study is to report the outcome of CAS-MIS-TKA in patients with knee arthritis and retained femoral implants. Between April 2006 and March 2008, eight patients with knee arthritis and retained femoral implants who underwent the CAS-MIS-TKA were retrospectively reviewed. Three of the eight patients had extra-articular deformity, including two femur bones and one tibia bone, in the preoperative examination. The anteroposterior, lateral, and long-leg weight-bearing radiographs carried out at 3-month follow-up was used to determine the mechanical axis of lower limb and the position of components. The mean preoperative femorotibial angle in patients without extra-articular deformity was 3.8° of varus and was corrected to 4.6° of valgus. With the use of navigation in MIS-TKA, the two patients in this study with extra-articular femoral deformity also obtained an ideal postoperative mechanical axis within 2° of normal alignment. Overall, there was a good restoration of postoperative mechanical alignment in all cases, with a mean angle of 0.4° of

  6. Strategies for reducing implant costs in the revision total knee arthroplasty episode of care.

    Science.gov (United States)

    Elbuluk, Ameer M; Old, Andrew B; Bosco, Joseph A; Schwarzkopf, Ran; Iorio, Richard

    2017-12-01

    Implant price has been identified as a significant contributing factor to high costs associated with revision total knee arthroplasty (rTKA). The goal of this study is to analyze the cost of implants used in rTKAs and to compare this pricing with 2 alternative pricing models. Using our institutional database, we identified 52 patients from January 1, 2014 to December 31, 2014. Average cost of components for each case was calculated and compared to the total hospital cost for that admission. Costs for an all-component revision were then compared to a proposed "direct to hospital" (DTH) standardized pricing model and a fixed price revision option. Potential savings were calculated from these figures. On average, 28% of the total hospital cost was spent on implants for rTKA. The average cost for revision of all components was $13,640 and ranged from $3000 to $28,000. On average, this represented 32.7% of the total hospital cost. Direct to hospital implant pricing could potentially save approximately $7000 per rTKA, and the fixed pricing model could provide a further $1000 reduction per rTKA-potentially saving $8000 per case on implants alone. Alternative implant pricing models could help lower the total cost of rTKA, which would allow hospitals to achieve significant cost containment.

  7. Low implant migration of the SIGMA® medial unicompartmental knee arthroplasty

    DEFF Research Database (Denmark)

    Koppens, Daan; Stilling, Maiken; Munk, Stig

    2017-01-01

    The purpose of this study was to evaluate implant migration of the fixed-bearing Sigma® medial unicompartmental knee arthroplasty (UKA). UKA is a regularly used treatment for patients with medial osteoarthritis (OA) of the knee. UKA has a higher revision rate than total knee arthroplasty. Implant...

  8. Failure of aseptic revision total knee arthroplasties.

    Science.gov (United States)

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-02-01

    In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties.

  9. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    Science.gov (United States)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  10. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    International Nuclear Information System (INIS)

    Teeter, Matthew G; Naudie, Douglas D R; Holdsworth, David W; Seslija, Petar; Milner, Jaques S; Nikolov, Hristo N; Yuan Xunhua

    2013-01-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm 3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements. (paper)

  11. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  12. Improved knee flexion following high-flexion total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Lionberger David R

    2012-06-01

    Full Text Available Abstract Background The application of new techniques and materials in total knee arthroplasty (TKA continue to be a primary focus in orthopedic surgery. The primary aim of the present study is to evaluate post TKA total range of motion (ROM among a group of patients who received a gender specific high-flexion design modification implant compared to a control group of patients who received non-gender specific implants. Methods and results The control group was comprised of 39 TKAs that were recruited pre-operatively and received the non-gender specific implant while the study group consisted of 39 TKAs who received gender specific implants. The study group yielded an improvement in mean post-operative ROM of 21° at 12 months, whereas the mean improvement in ROM among the control group was 11°. Thus, the study group had a 10° increased ROM improvement (91% over the control group (p = 0.00060. In addition, 100% of the subjects with gender specific high-flexion implants achieved greater or equal ROM post-operatively compared to 82% for the control cohort. Lastly, women who exhibited greater pre-operative ROM and lower body mass index (BMI were found to benefit the most with the gender specific prosthesis. Conclusion Our study demonstrates that among subjects with a normal BMI, the gender specific high-flexion knee implant is associated with increased ROM as compared to the non-gender specific non-high-flexion implant designs.

  13. Alpine Skiing With total knee ArthroPlasty (ASWAP)

    DEFF Research Database (Denmark)

    Koesters, A.; Poetzelsberger, B.; Dela, F.

    2015-01-01

    The aim of this study was to monitor the long-term effects of skiing on health-related parameters and implant related factors like loosening and wear in patients with total knee arthroplasty. This paper describes the overall study design, general demographics, and physiological demand of the inte......The aim of this study was to monitor the long-term effects of skiing on health-related parameters and implant related factors like loosening and wear in patients with total knee arthroplasty. This paper describes the overall study design, general demographics, and physiological demand...

  14. Development and fabrication of patient-specific knee implant using additive manufacturing techniques

    Science.gov (United States)

    Zammit, Robert; Rochman, Arif

    2017-10-01

    Total knee replacement is the most effective treatment to relief pain and restore normal function in a diseased knee joint. The aim of this research was to develop a patient-specific knee implant which can be fabricated using additive manufacturing techniques and has reduced wear rates using a highly wear resistant materials. The proposed design was chosen based on implant requirements, such as reduction in wear rates as well as strong fixation. The patient-specific knee implant improves on conventional knee implants by modifying the articulating surfaces and bone-implant interfaces. Moreover, tribological tests of different polymeric wear couples were carried out to determine the optimal materials to use for the articulating surfaces. Finite element analysis was utilized to evaluate the stresses sustained by the proposed design. Finally, the patient-specific knee implant was successfully built using additive manufacturing techniques.

  15. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  16. Total knee arthroplasty in patients with a previous patellectomy.

    Science.gov (United States)

    Maslow, Jed; Zuckerman, Joseph D; Immerman, Igor

    2013-01-01

    Post-patellectomy patients represent a specific subgroup of patients that may develop arthritis and persistent knee pain and potentially require treatment with total knee arthroplasty. This article reviews the treatment and functional outcomes following total knee arthroplasty in patients with prior patellectomy. A case report is presented as an example of the clinical management of a post-patellectomy patient with significant knee pain and disability treated with total knee arthroplasty. Emphasis will be placed in decision- making, specifically with the use of a posterior stabilized implant. In addition, postoperative strengthening of the quadriceps is essential to compensate for the lack of the patella and increase the success of total knee arthroplasty in this subgroup of patients.

  17. The association between metal allergy, total knee arthroplasty, and revision

    DEFF Research Database (Denmark)

    Münch, Henrik J; Jakobsen, Stig Storgaard; Olesen, Jens T

    2015-01-01

    BACKGROUND AND PURPOSE: It is unclear whether delayed-type hypersensitivity reactions against implanted metals play a role in the etiopathogenesis of malfunctioning total knee arthroplasties. We therefore evaluated the association between metal allergy, defined as a positive patch test reaction...... to common metal allergens, and revision surgery in patients who underwent knee arthroplasty. PATIENTS AND METHODS: The nationwide Danish Knee Arthroplasty Register, including all knee-implanted patients and revisions in Denmark after 1997 (n = 46,407), was crosslinked with a contact allergy patch test......, the prevalence of cobalt and chromium allergy was markedly higher. Metal allergy that was diagnosed before implant surgery appeared not to increase the risk of implant failure and revision surgery. INTERPRETATION: While we could not confirm that a positive patch test reaction to common metals is associated...

  18. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    Directory of Open Access Journals (Sweden)

    Clifford AG

    2013-05-01

    Full Text Available Anton G Clifford,1 Stefan M Gabriel,1 Mary O’Connell,1 David Lowe,1 Larry E Miller,2,3 Jon E Block31Moximed, Inc, Hayward, CA, USA; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USAAbstract: Symptomatic medial compartment knee osteoarthritis (OA is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA.Keywords: KineSpring, knee, medial, osteoarthritis, prosthesis

  19. Predictors of clinical outcome in total hip and knee replacement : a methodological appraisal of implants and patient factors

    NARCIS (Netherlands)

    Keurentjes, Johan Christiaan

    2014-01-01

    In this thesis, we studied both implants and patient and surgeon factors as predictors of clinical outcome after total hip and knee replacement. Additionally, we studied a number of methodological aspects of orthopaedic research, such as competing risks in estimating the probability of revision

  20. TOTAL KNEE REPLACEMENT IN PATIENTS WITH BELOW-KNEE AMPUTATION

    Science.gov (United States)

    Karam, Matthew D; Willey, Michael; Shurr, Donald G

    2010-01-01

    Total knee replacement (TKR) is reserved for patients with severe and disabling arthritis that is non-responsive to conservative measures. Based on existing data, total knee replacement is a safe and cost-effective treatment for alleviating pain and improving physical function in patients who do not respond to conservative therapy. Despite the large variation in health status of patients and types of prosthesis implanted, total knee replacement has proven to be a relatively low risk and successful operation. Each year in the United States surgeons perform approximately 300,000 TKR.1 Likewise, lower extremity amputation is commonly performed in the United States with an annual incidence of 110,000 per year.2 Nearly 70% of all lower extremity amputations are performed as the result of chronic vascular disease, followed by trauma (22%), congenital etiology and tumor (4% each).3 Approximately 50% of all lower extremity amputations are performed secondary to complications from Diabetes Mellitus. Norvell et al. demonstrated that patients who have previously undergone transtibial amputation and ambulate with a prosthesis are more likely to develop degenerative joint disease in the con-tralateral extremity than the ipsilateral extremity.4 Further, radiographic changes consistent with osteoporosis have been demonstrated in up to 88% of limbs that have undergone transtibial amputation.8 To our knowledge, there have been only three reported cases of total knee replacement in patients with ipsilateral transtibial amputation.5,7 The purpose of the present study is to review the existing data on total knee replacement in patients who have undergone transtibial amputation. Further we present a patient with a transtibial amputation who underwent contralateral total knee replacement. PMID:21045987

  1. Bicruciate-retaining Total Knee Replacement Provides Satisfactory Function and Implant Survivorship at 23 Years.

    Science.gov (United States)

    Pritchett, James W

    2015-07-01

    One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean

  2. Comparison of cemented and uncemented fixation in total knee arthroplasty.

    Science.gov (United States)

    Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian

    2013-05-01

    As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.

  3. Five year survival analysis of an oxidised zirconium total knee arthroplasty.

    Science.gov (United States)

    Holland, Philip; Santini, Alasdair J A; Davidson, John S; Pope, Jill A

    2013-12-01

    Zirconium total knee arthroplasties theoretically have a low incidence of failure as they are low friction, hard wearing and hypoallergenic. We report the five year survival of 213 Profix zirconium total knee arthroplasties with a conforming all polyethylene tibial component. Data was collected prospectively and multiple strict end points were used. SF12 and WOMAC scores were recorded pre-operatively, at three months, at twelve months, at 3 years and at 5 years. Eight patients died and six were "lost to follow-up". The remaining 199 knees were followed up for five years. The mean WOMAC score improved from 56 to 35 and the mean SF12 physical component score improved from 28 to 34. The five year survival for failure due to implant related reasons was 99.5% (95% CI 97.4-100). This was due to one tibial component becoming loose aseptically in year zero. Our results demonstrate that the Profix zirconium total knee arthroplasty has a low medium term failure rate comparable to the best implants. Further research is needed to establish if the beneficial properties of zirconium improve long term implant survival. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  5. Malassezia species infection of the synovium after total knee arthroplasty surgery

    Directory of Open Access Journals (Sweden)

    Leylabadlo, Hamed Ebrahimzadeh

    2016-09-01

    Full Text Available Infection is a serious complication after implantation of total knee-prostheses. However, fungal infection is rarely found in periprosthetic joints, and in most reports, the infecting organism is a species. This is a case report of infection after left knee total arthroplasty caused by species. The patient is still undergoing antifungal therapy with voriconazole and is still being followed-up. To the authors’ knowledge, the present case is the first report of species in a patient after total knee arthroplasty.

  6. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    Directory of Open Access Journals (Sweden)

    Jörn Reinders

    2014-01-01

    Full Text Available Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P≤0.001 were observed for the unstable knee (14.58±0.56 mg/106 cycles compared to the stable knee (7.97 ± 0.87 mg/106 cycles. A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P≤0.01. This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study.

  7. [Restricted motion after total knee arthroplasty].

    Science.gov (United States)

    Kucera, T; Urban, K; Karpas, K; Sponer, P

    2007-10-01

    The aim of the study was to ascertain what proportion of patients undergoing total knee arthroplasty (TKA) complain of restricted knee joint motion, and to investigate options for improvement of this situation. Our evaluation included a group of 796 patients treated with TKA at our department in the period from January 1, 1990, to December 31, 2004. In all cases, a condylar implant with preservation of the posterior cruciate ligaments was used. In addition to medical history, the range of motion, knee joint malalignment and radiological findings were assessed before surgery. After THA, the type of implant and complications, if any, were recorded, and improvement in joint motion was followed up. Based on the results of Kim et al., flexion contracture equal to or higher than 15 degrees and/or flexion less than 75 degrees were made the criteria of stiffness after THA. Patients with restricted THA motion who had aseptic or septic implant loosening were not included. Of the 796 evaluated patients, 32 (4.14 %) showed restricted motion after total knee arthroplasty, as assessed by the established criteria. In 16 patients, stiffness defined by these criteria had existed before surgery, and three patients showed an excessive production of adhesions and heterotopic ossifications. In three patients, the implantation procedure resulted in an elevated level of the original joint line and subsequent development of patella infera and increased tension of the posterior cruciate ligament. Four patients declined physical therapy and, in six, the main cause of stiffness could not be found. Seventeen patients did not require surgical therapy for restricted motion; TKA provided significant pain relief and they considered the range of motion achieved to be sufficient. One patient underwent redress 3 months after surgery, but with no success. Repeated releases of adhesions, replacement of a polyethylene liner and revision surgery of the extensor knee structures were performed in 15

  8. Outcome of total knee replacement following explantation and cemented spacer therapy.

    Science.gov (United States)

    Ghanem, Mohamed; Zajonz, Dirk; Bollmann, Juliane; Geissler, Vanessa; Prietzel, Torsten; Moche, Michael; Roth, Andreas; Heyde, Christoph-E; Josten, Christoph

    2016-01-01

    Infection after total knee replacement (TKR) is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation. A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient's group comprised of 53% (18) males and 47% (16) females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years). We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. We reported 31.4% (11) reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation) after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation) after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation. No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation. Our data point out to the fact that a longer time interval between

  9. Outcome of total knee replacement following explantation and cemented spacer therapy

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-03-01

    Full Text Available Background: Infection after total knee replacement (TKR is one of the serious complications which must be pursued with a very effective therapeutic concept. In most cases this means revision arthroplasty, in which one-setting and two-setting procedures are distinguished. Healing of infection is the conditio sine qua non for re-implantation. This retrospective work presents an assessment of the success rate after a two-setting revision arthroplasty of the knee following periprosthetic infection. It further considers drawing conclusions concerning the optimal timing of re-implantation.Patients and methods: A total of 34 patients have been enclosed in this study from September 2005 to December 2013. 35 re-implantations were carried out following explantation of total knee and implantation of cemented spacer. The patient’s group comprised of 53% (18 males and 47% (16 females. The average age at re-implantation time was 72.2 years (ranging from 54 to 85 years. We particularly evaluated the microbial spectrum, the interval between explantation and re-implantation, the number of surgeries that were necessary prior to re-implantation as well as the postoperative course. Results: We reported 31.4% (11 reinfections following re-implantation surgeries. The number of the reinfections declined with increasing time interval between explantation and re-implantation. Patients who developed reinfections were operated on (re-implantation after an average of 4.47 months. Those patients with uncomplicated course were operated on (re-implantation after an average of 6.79 months. Nevertheless, we noticed no essential differences in outcome with regard to the number of surgeries carried out prior to re-implantation. Mobile spacers proved better outcome than temporary arthrodesis with intramedullary fixation.Conclusion: No uniform strategy of treatment exists after peri-prosthetic infections. In particular, no optimal timing can be stated concerning re-implantation

  10. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    Science.gov (United States)

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  11. Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units

    Science.gov (United States)

    Wilson, Brooke E.; Meneghini, Michael; Anton, Steven R.

    2015-04-01

    The knee replacement is the second most common orthopedic surgical intervention in the United States, but currently only 1 in 5 knee replacement patients are satisfied with their level of pain reduction one year after surgery. It is imperative to make the process of knee replacement surgery more objective by developing a data driven approach to ligamentous balance, which increases implant life. In this work, piezoelectric materials are considered for both sensing and energy harvesting applications in total knee replacement implants. This work aims to embed piezoelectric material in the polyethylene bearing of a knee replacement unit to act as self-powered sensors that will aid in the alignment and balance of the knee replacement by providing intraoperative feedback to the surgeon. Postoperatively, the piezoelectric sensors can monitor the structural health of the implant in order to perceive potential problems before they become bothersome to the patient. Specifically, this work will present on the use of finite element modeling coupled with uniaxial compression testing to prove that piezoelectric stacks can be utilized to harvest sufficient energy to power sensors needed for this application.

  12. The Cruciate Ligaments in Total Knee Arthroplasty.

    Science.gov (United States)

    Parcells, Bertrand W; Tria, Alfred J

    2016-01-01

    The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction.

  13. Knee effusion after total knee replacement.

    OpenAIRE

    Cameron, H. U.

    1993-01-01

    The various causes of effusions in artificial knees can be divided into four groups: implant related, technique related, interface problems, and infection. Diagnosis can be made from the patient's history and a clinical examination. Treatment is usually surgical revision.

  14. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    Science.gov (United States)

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  15. Influence of conformity on the wear of total knee replacement: An experimental study.

    Science.gov (United States)

    Brockett, Claire L; Carbone, Silvia; Fisher, John; Jennings, Louise M

    2018-02-01

    Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection.

  16. Instability following total knee arthroplasty.

    Science.gov (United States)

    Rodriguez-Merchan, E Carlos

    2011-10-01

    Background Knee prosthesis instability (KPI) is a frequent cause of failure of total knee arthroplasty. Moreover, the degree of constraint required to achieve immediate and long-term stability in total knee arthroplasty (TKA) is frequently debated. Questions This review aims to define the problem, analyze risk factors, and review strategies for prevention and treatment of KPI. Methods A PubMed (MEDLINE) search of the years 2000 to 2010 was performed using two key words: TKA and instability. One hundred and sixty-five initial articles were identified. The most important (17) articles as judged by the author were selected for this review. The main criteria for selection were that the articles addressed and provided solutions to the diagnosis and treatment of KPI. Results Patient-related risk factors predisposing to post-operative instability include deformity requiring a large surgical correction and aggressive ligament release, general or regional neuromuscular pathology, and hip or foot deformities. KPI can be prevented in most cases with appropriate selection of implants and good surgical technique. When ligament instability is anticipated post-operatively, the need for implants with a greater degree of constraint should be anticipated. In patients without significant varus or valgus malalignment and without significant flexion contracture, the posterior cruciate ligament (PCL) can be retained. However, the PCL should be sacrificed when deformity exists particularly in patients with rheumatoid arthritis, previous patellectomy, previous high tibial osteotomy or distal femoral osteotomy, and posttraumatic osteoarthritis with disruption of the PCL. In most cases, KPI requires revision surgery. Successful outcomes can only be obtained if the cause of KPI is identified and addressed. Conclusions Instability following TKA is a common cause of the need for revision. Typically, knees with deformity, rheumatoid arthritis, previous patellectomy or high tibial osteotomy, and

  17. Patient - implant dimension mismatch in total knee arthroplasty: Is it worth worrying? An Indian scenario

    Directory of Open Access Journals (Sweden)

    Jai Thilak

    2016-01-01

    Full Text Available Background: The correct sizing of the components in both anteroposterior and mediolateral (ML dimensions is crucial for the success of a total knee arthroplasty (TKA. The size of the implants selected is based on the intraoperative measurements. The currently used TKA implants available to us are based on morphometric measurements obtained from a Western/Caucasian population. Hence, the risk of component ML mismatch is more common in Asian sub-population, as they are of a smaller built and stature. This study aims to look into the following aspects agnitude of the ML mismatch between the femoral component and the patient′s anatomical dimension, evaluation of gender variations in distal femur dimensions, and gender-wise and implant-wise correlation of ML mismatch. Materials and Methods: Intraoperatively, the distal femoral dimensions were measured using sterile calipers after removing the osteophytes and compared with the ML dimension of the implant used. ML mismatch length thus obtained is correlated with the various parameters. Results: Males showed larger distal femoral dimensions when compared to females. Males had larger ML mismatch. None of the implants used perfectly matched the patient′s anatomical dimensions. Patients with larger mismatch had lower scorings at 2 years postoperative followup. Conclusion: Implant manufacturers need to design more options of femoral implants for a better fit in our subset of patients. The exact magnitude of mismatch which can cause functional implications need to be made out. The mismatch being one of the important factors for the success of the surgery, we should focus more on this aspect.

  18. Total knee arthroplasty with an oxidised zirconium femoral component: ten-year survivorship analysis.

    Science.gov (United States)

    Ahmed, I; Salmon, L J; Waller, A; Watanabe, H; Roe, J P; Pinczewski, L A

    2016-01-01

    Oxidised zirconium was introduced as a material for femoral components in total knee arthroplasty (TKA) as an attempt to reduce polyethylene wear. However, the long-term survival of this component is not known. We performed a retrospective review of a prospectively collected database to assess the ten year survival and clinical and radiological outcomes of an oxidised zirconium total knee arthroplasty with the Genesis II prosthesis. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS) and a patient satisfaction scale were used to assess outcome. A total of 303 consecutive TKAs were performed in 278 patients with a mean age of 68 years (45 to 89). The rate of survival ten years post-operatively as assessed using Kaplan-Meier analysis was 97% (95% confidence interval 94 to 99) with revision for any reason as the endpoint. There were no revisions for loosening, osteolysis or failure of the implant. There was a significant improvement in all components of the WOMAC score at final follow-up (p zirconium TKA gives comparable rates of survival with other implants and excellent functional outcomes ten years post-operatively. Total knee arthroplasty with an oxidised zirconium femoral component gives comparable long-term rates of survival and functional outcomes with conventional implants. ©2016 The British Editorial Society of Bone & Joint Surgery.

  19. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    Science.gov (United States)

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component. The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years).The primary indication was 14 times osteoarthritis and 5 times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years). Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants. At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The differences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant. Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee

  20. Expectations in patients with total knee arthroplasty.

    Science.gov (United States)

    Tekin, Burcu; Unver, Bayram; Karatosun, Vasfi

    2012-01-01

    The primary objective of total knee arthroplasty (TKA) is to decrease pain and restore functional knee joint. Current hypotheses indicate higher knee flexion is required in terms of life style, culture and expectations in Eastern communities. Therefore, society-specific features related to life style and cultural habits are needed. The objective of this study was to investigate the expectations of patients undergoing TKA. The study included 131 patients (18 male, 113 female; mean age: 66.2 ± 8.3 years) who underwent cemented TKA due to knee osteoarthritis. All patients were operated by the same surgeon using the same implant and surgical technique. Patients were evaluated using the Hospital for Special Surgery (HSS) knee score, a 15-item clinical knee assessment questionnaire and the HSS knee arthroplasty expectation questionnaire. Mean HSS score for the right knee was 89.2 ± 10.5 and for the left knee was 89.6 ± 9.4. The two most expected outcomes were improvements in pain (99.2%) and gait (96.2%) and the two least expected outcomes were improvements in psychological well-being (22.9%) and communicative skills (35.1%). Expectations were not affected by education and working conditions. Patients' most expected outcomes were improvement in pain and restoration of function (gait, climbing stairs and no need of assistive devices), similar to Western and American communities.

  1. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  2. Total knee replacement in patients with diffuse villonodular synovitis

    Directory of Open Access Journals (Sweden)

    Lucio Flávio Biondi Pinheiro Júnior

    Full Text Available ABSTRACT This paper reports a case of diffuse pigmented villonodular synovitis (DPVNS, associated with advanced gonarthrosis, submitted to total knee replacement. The patient had progressive pain and swelling. She had two previous surgeries, firstly arthroscopic , synovectomy and subsequently open synovectomy associated with radiotherapy, with recurrence of the disease. Magnetic resonance imaging revealed diffuse synovitis, advanced arthrosis, and bone cysts. The patient was submitted to a total knee replacement and synovectomy. There was a good postoperative clinical course, with improvement of pain, function, and joint edema on examination. The patient will be followed regarding the possibility of disease recurrence and implant survival.,

  3. No difference in gait between posterior cruciate retention and the posterior stabilized design after total knee arthroplasty

    NARCIS (Netherlands)

    van den Boom, Lennard G. H.; Halbertsma, Jan P. K.; van Raaij, Jos J. A. M.; Brouwer, Reinoud W.; Bulstra, Sjoerd K.; van den Akker-Scheek, Inge

    2014-01-01

    In the present study, knee joint kinematics (e.g. knee flexion/extension) and kinetics (e.g. knee flexion moments) are assessed after total knee arthroplasty (TKA) between patients implanted with either a unilateral posterior stabilized (PS) and a posterior cruciate-retaining (PCR) design. It was

  4. Biomechanical evaluation of tibial bone adaptation after revision total knee arthroplasty: A comparison of different implant systems.

    Directory of Open Access Journals (Sweden)

    María Paz Quilez

    Full Text Available The best methods to manage tibial bone defects following total knee arthroplasty remain under debate. Different fixation systems exist to help surgeons reconstruct knee osseous bone loss (such as tantalum cones, cement, modular metal augments, autografts, allografts and porous metaphyseal sleeves However, the effects of the various solutions on the long-term outcome remain unknown. In the present work, a bone remodeling mathematical model was used to predict bone remodeling after total knee arthroplasty (TKA revision. Five different types of prostheses were analyzed: one with a straight stem; two with offset stems, with and without supplements; and two with sleeves, with and without stems. Alterations in tibia bone density distribution and implant Von Mises stresses were quantified. In all cases, the bone density decreased in the proximal epiphysis and medullary channels, and an increase in bone density was predicted in the diaphysis and around stem tips. The highest bone resorption was predicted for the offset prosthesis without the supplement, and the highest bone formation was computed for the straight stem. The highest Von Mises stress was obtained for the straight tibial stem, and the lowest was observed for the stemless metaphyseal sleeves prosthesis. The computational model predicted different behaviors among the five systems. We were able to demonstrate the importance of choosing an adequate revision system and that in silico models may help surgeons choose patient-specific treatments.

  5. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    Science.gov (United States)

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  6. Bilateral custom-fit total knee arthroplasty in a patient with poliomyelitis.

    Science.gov (United States)

    Tardy, Nicolas; Chambat, Pierre; Murphy, Colin G; Fayard, Jean-Marie

    2014-09-01

    In limbs affected by poliomyelitis, total knee arthroplasty results in satisfactory pain relief. However, the risk of failure is high, especially if the preoperative quadriceps power is low. Therefore, treating osteoarthritis in the current patient represented a challenging procedure. A 66-year-old man presented with tricompartmental osteoarthritis of both knees, with valgus deformity of 14° on the left knee and 11° on the right knee. He walked with a bilateral knee recurvatum of 30° and a grade 1 quadriceps power. The authors treated both knees with cemented custom-fit hinged total knee arthroplasty with 30° of recurvatum in the tibial keel. Clinical scores showed good results 1 year postoperatively, especially on the subjective data of quality of life and function. At follow-up, radiographs showed good total knee arthroplasty positioning on the right side and a small mechanical loosening at the end of the tibial keel on the left side. Only 5 studies (Patterson and Insall; Moran; Giori and Lewallen; Jordan et al; and Tigani et al) have reported total knee arthroplasty results in patients with poliomyelitis. This study reports an original case of bilateral custom-fit hinged total knee arthroplasty in a patient with poliomyelitis. To the authors' knowledge, this is the first report of this type of procedure in the literature. The key point is the degree of recurvatum that is needed to allow walking, avoiding excessive constraints on the implants that can lead to early mechanical failure. Copyright 2014, SLACK Incorporated.

  7. Special features of total knee replacement in hemophilia.

    Science.gov (United States)

    Rodriguez-Merchan, Emerito Carlos

    2013-12-01

    Total knee replacement is an operation frequently needed by hemophilia patients, which greatly improves their quality of life. This operation, however, carries a higher risk of bleeding and infection for hemophiliacs than it does for osteoarthritis sufferers. It is advisable to implant prosthetic components using antibiotic-loaded cement. It is essential to maintain a level of 100% of the replacement clotting factor for 2 weeks. Hematological treatment must be established, depending on the patient's factor levels and other pharmacokinetic parameters such as recovery and half-life, optimal doses and treatment time. It is preferable to use general anesthesia due to the risk of spinal bleeding. The lifespan of total knee replacement in hemophilic patients is shorter than in patients with osteoarthritis because of the increased risk of infection.

  8. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Takaharu E-mail: yamazaki@image.med.osaka-u.ac.jp; Watanabe, Tetsu; Nakajima, Yoshikazu; Sugamoto, Kazuomi; Tomita, Tetsuya; Maeda, Daisuke; Sahara, Wataru; Yoshikawa, Hideki; Tamura, Shinichi

    2005-01-01

    The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

  9. No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty

    NARCIS (Netherlands)

    van Hove, R.P.; Brohet, R.M.; van Royen, B.J.; Nolte, P.A.

    2015-01-01

    Purpose: Titanium nitride (TiN) coating of cobalt–chromium–molybdenum (CoCrMo) implants has shown to improve the biomechanical properties of the implant surface and to reduce adhesive wear in vitro. It is yet unknown whether TiN coating of total knee prosthesis (TKP) affects the postoperative

  10. Autologous blood transfusion in total knee replacement surgery.

    Science.gov (United States)

    Sarkanović, Mirka Lukić; Gvozdenović, Ljiljana; Savić, Dragan; Ilić, Miroslav P; Jovanović, Gordana

    2013-03-01

    Total knee replacement (TKR) surgery is one of the most frequent and the most extensive procedures in orthopedic surgery, accompanied with some serious complications. Perioperative blood loss is one of the most serious losses, so it is vital to recognize and treat such losses properly. Autologous blood transfusion is the only true alternative for the allogeneic blood. The aim of this study was to to examine if autologous blood transfusion reduces usage of allogenic blood in total knee replacement surgery, as well as to examine possible effect of autologous blood transfusion on postoperative complications, recovery and hospital stay of patients after total knee replacement surgery. During the controlled, prospective, randomised study we compared two groups of patients (n = 112) with total prosthesis implanted in their knee. The group I consisted of the patients who received the transfusion of other people's (allogeneic) blood (n = 57) and the group II of the patients whose blood was collected postoperatively and then given them [their own (autologous) blood] (n = 55). The transfusion trigger for both groups was hemoglobin level of 85 g/L. In the group of patients whose blood was collected perioperatively only 9 (0.9%) of the patients received transfusion of allogeneic blood, as opposed to the control group in which 98.24% of the patients received the transfusion of allogeneic blood (p blood was collected stayed in hospital for 6.18 days, while the patients of the control group stayed 7.67 days (p blood transfusion is a very effective method for reducing consumption of allogenic blood and thus, indirectly for reducing all complications related to allogenic blood transfusion. There is also a positive influence on postoperative recovery after total knee replacement surgery due to the reduction of hospital stay, and indirectly on the reduction of hospital costs.

  11. Backside wear in modern total knee designs.

    Science.gov (United States)

    Jayabalan, Prakash; Furman, Bridgette D; Cottrell, Jocelyn M; Wright, Timothy M

    2007-02-01

    Although modularity affords various options to the orthopedic surgeon, these benefits come at a price. The unintended bearing surface between the back surface of the tibial insert and the metallic tray results in micromotion leading to polyethylene wear debris. The objective of this study was to examine the backside wear of tibial inserts from three modern total knee designs with very different locking mechanisms: Insall-Burstein II (IB II), Optetrak, and Advance. A random sample of 71 inserts were obtained from our institution's retrieval collection and examined to assess the extent of wear, depth of wear, and wear damage modes. Patient records were also obtained to determine patient age, body mass index, length of implantation, and reason for revision. Modes of wear damage (abrasion, burnishing, scratching, delamination, third body debris, surface deformation, and pitting) were then scored in each zone from 0 to 3 (0 = 0%, 1 = 0-10%, 2 = 10-50%, and 3 = >50%). The depth of wear was subjectively identified as removal of manufacturing identification markings stamped onto the inferior surface of the polyethylene. Both Advance and IB II polyethylene inserts showed significantly higher scores for backside wear than the Optetrak inserts. All IB II and Advance implants showed evidence of backside wear, whereas 17% (5 out of 30) of the retrieved Optetrak implants had no observable wear. There were no significant differences when comparing the depth of wear score between designs. The locking mechanism greatly affects the propensity for wear and should be considered when choosing a knee implant system.

  12. Loss of knee-extension strength is related to knee swelling after total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten T; Bencke, Jesper

    2010-01-01

    To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA).......To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA)....

  13. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    Science.gov (United States)

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  14. The role of hinges in primary total knee replacement.

    Science.gov (United States)

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  15. Medium term results of total knee arthroplasty as a primary treatment for knee fractures

    Directory of Open Access Journals (Sweden)

    Ebied Ayman

    2018-01-01

    Conclusion: Knee arthroplasty achieves highly successful outcome when performed as a primary treatment for comminuted intra and periarticular knee fractures in elderly patients. Survival of implants and functional range of movement at midterm are excellent.

  16. Analysis of in vitro and in vivo function of total knee replacements using dynamic contact models

    Science.gov (United States)

    Zhao, Dong

    Despite the high incidence of osteoarthritis in human knee joint, its causes remain unknown. Total knee replacement (TKR) has been shown clinically to be effective in restoring the knee function. However, wear of ultra-high molecular weight polyethylene has limited the longevity of TKRs. To address these important issues, it is necessary to investigate the in vitro and in vivo function of total knee replacements using dynamic contact models. A multibody dynamic model of an AMTI knee simulator was developed. Incorporating a wear prediction model into the contact model based on elastic foundation theory enables the contact surface to take into account creep and wear during the dynamic simulation. Comparisons of the predicted damage depth, area, and volume lost with worn retrievals from a physical machine were made to validate the model. In vivo tibial force distributions during dynamic and high flexion activities were investigated using the dynamic contact model. In vivo medial and lateral contact forces experienced by a well-aligned instrumented knee implant, as well as upper and lower bounds on contact pressures for a variety of activities were studied. For all activities, the predicted medial and lateral contact forces were insensitive to the selected material model. For this patient, the load split during the mid-stance phase of gait and during stair is more equal than anticipated. The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. In vivo data collected from a subject with an instrumented knee implant were analyzed to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe out) while instrumented implant, video motion, and ground reaction data were simultaneously collected. The high correlation coefficient

  17. Management of Medial Collateral Ligament Injury During Primary Total Knee Arthroplasty: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Paul Della Torre, MD

    2014-07-01

    Full Text Available Medial collateral ligament injury during primary total knee arthroplasty is a recognised complication potentially resulting in valgus instability, suboptimal patient outcomes and a higher rate of revision or reoperation. Options for management include primary repair with or without augmentation, reconstruction or immediate conversion to prosthesis with greater constraint, in conjunction with various postoperative rehabilitation protocols. Inconsistent recommendations throughout the orthopaedic literature have made the approach to managing this complication problematic. The objective of this study was to review the available literature to date comparing intraoperative and postoperative management options for primary total knee arthroplasty complicated by recognised injury to the medial collateral ligament. This systematic literature review was prospectively registered with PROSPERO (#CRD42014008866 and performed in accordance with PRISMA guidelines including a PRISMA flow diagram. Five articles satisfied the inclusion criteria. Each was a retrospective, observational cohort or case series with small numbers reported, inconsistent methodology and incompletely reported outcomes. Four of the five studies managing medial collateral ligament injury during total knee arthroplasty (47/84 patients with direct repair with or without autograft augmentation reported good outcomes with no revision or reoperation required for symptomatic instability over a follow-up period of 16 months to almost 8 years. The fifth study with a follow-up to 10 years and a high rate of conversion to unlinked semi constrained total knee arthroplasty implant (30/37 patients reported a greater incidence of revision due to instability, in patients in whom the medial collateral ligament injury was directly repaired without added constraint. Overall balance of evidence is in favour of satisfactory outcomes without symptomatic instability following direct repair with or without

  18. Development of Total Knee Replacement Digital Templating Software

    Science.gov (United States)

    Yusof, Siti Fairuz; Sulaiman, Riza; Thian Seng, Lee; Mohd. Kassim, Abdul Yazid; Abdullah, Suhail; Yusof, Shahril; Omar, Masbah; Abdul Hamid, Hamzaini

    In this study, by taking full advantage of digital X-ray and computer technology, we have developed a semi-automated procedure to template knee implants, by making use of digital templating method. Using this approach, a software system called OrthoKneeTMhas been designed and developed. The system is to be utilities as a study in the Department of Orthopaedic and Traumatology in medical faculty, UKM (FPUKM). OrthoKneeTMtemplating process employs uses a technique similar to those used by many surgeons, using acetate templates over X-ray films. Using template technique makes it easy to template various implant from every Implant manufacturers who have with a comprehensive database of templates. The templating functionality includes, template (knee) and manufactures templates (Smith & Nephew; and Zimmer). From an image of patient x-ray OrthoKneeTMtemplates help in quickly and easily reads to the approximate template size needed. The visual templating features then allow us quickly review multiple template sizes against the X-ray and thus obtain the nearly precise view of the implant size required. The system can assist by templating on one patient image and will generate reports that can accompany patient notes. The software system was implemented in Visual basic 6.0 Pro using the object-oriented techniques to manage the graphics and objects. The approaches for image scaling will be discussed. Several of measurement in orthopedic diagnosis process have been studied and added in this software as measurement tools features using mathematic theorem and equations. The study compared the results of the semi-automated (using digital templating) method to the conventional method to demonstrate the accuracy of the system.

  19. Arthroscopic treatment of patients with moderate arthrofibrosis after total knee replacement.

    Science.gov (United States)

    Jerosch, Joerg; Aldawoudy, Akram M

    2007-01-01

    The purpose of this study was to document the effect of arthroscopic management in patients with knee stiffness after total knee replacement. We present a case series study, in which 32 patients have been treated for moderate arthrofibrosis of the knee after total knee replacement, with the same regimen. We have excluded all cases of stiffness, because of infection, mechanical mal-alignment, loosening of the implants and other obvious reasons of stiffness of the knee, rather than pure arthrofibrosis. All patients first underwent a trial of conservative treatment before going for arthroscopic management. A pain catheter for femoral nerve block was inserted just before anesthesia for post-operative pain management. Arthroscopic arthrolysis of the intra-articular pathology was performed in a standardized technique with release of all fibrous bands in the suprapatellar pouch, reestablishing the medial and lateral gutter, release of the patella, resection of the remaining meniscal tissue or an anterior cyclops, if needed. Intensive physiotherapy and continuous passive motion were to start immediately post-operatively. All the patients were available for the follow up and they were evaluated using the knee society rating system. A total of 25 of the 32 procedures resulted in an improvement of the patients knee score. All the knees operated upon had intra-articular fibrous bands, hypertrophic synovitis and peri-patellar adhesions. A total of eight patients suffered from an anterior cyclops lesion and six patients showed pseudomenicus. In 19 cases a medial and lateral relapse of the patella was performed; only 5 patients got an isolated lateral release. The mean knee flexion was 119 degrees (100-130) at the end of arthroscopy and was 97 degrees (75-115) at the last follow up. The eight patients with extension lags decreased from 27 degrees (10 degrees-35 degrees) pre-operatively to 4 degrees (0-10) at time of follow up. The average knee society ratings increased from 70

  20. Enclosed Electronic System for Force Measurements in Knee Implants

    Directory of Open Access Journals (Sweden)

    David Forchelet

    2014-08-01

    Full Text Available Total knee arthroplasty is a widely performed surgical technique. Soft tissue force balancing during the operation relies strongly on the experience of the surgeon in equilibrating tension in the collateral ligaments. Little information on the forces in the implanted prosthesis is available during surgery and post-operative treatment. This paper presents the design, fabrication and testing of an instrumented insert performing force measurements in a knee prosthesis. The insert contains a closed structure composed of printed circuit boards and incorporates a microfabricated polyimide thin-film piezoresistive strain sensor for each condylar compartment. The sensor is tested in a mechanical knee simulator that mimics in-vivo conditions. For characterization purposes, static and dynamic load patterns are applied to the instrumented insert. Results show that the sensors are able to measure forces up to 1.5 times body weight with a sensitivity fitting the requirements for the proposed use. Dynamic testing of the insert shows a good tracking of slow and fast changing forces in the knee prosthesis by the sensors.

  1. Biomaterial Hypersensitivity: Is It Real? Supportive Evidence and Approach Considerations for Metal Allergic Patients following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Mitchelson

    2015-01-01

    Full Text Available The prospect of biomaterial hypersensitivity developing in response to joint implant materials was first presented more than 30 years ago. Many studies have established probable causation between first-generation metal-on-metal hip implants and hypersensitivity reactions. In a limited patient population, implant failure may ultimately be related to metal hypersensitivity. The examination of hypersensitivity reactions in current-generation metal-on-metal knee implants is comparatively limited. The purpose of this study is to summarize all available literature regarding biomaterial hypersensitivity after total knee arthroplasty, elucidate overall trends about this topic in the current literature, and provide a foundation for clinical approach considerations when biomaterial hypersensitivity is suspected.

  2. The Columbus Knee System: 4-Year Results of a New Deep Flexion Design Compared to the NexGen Full Flex Implant

    Directory of Open Access Journals (Sweden)

    D. Goebel

    2012-01-01

    Full Text Available The Columbus knee system is designed as a standard knee implant to allow high flexion without additional bone resection. Between August, 2004 and March, 2010 we performed 109 total knee arthroplasties of the Columbus knee system in 101 consecutive patients suffering from primary arthrosis of the knee. Mean age was 72.4 years in women and 70.3 years in men. Mean followup was 47.3 months. The 4-year results of a group of patients who received the NexGen Full Flex implant operated by the same surgeon were used for comparison. Mean total knee score was Columbus: 175.6 and NexGen Flex: 183.4; =0.037. Mean operation time was 53 min for Columbus and 66 min for NexGen Flex; 0.05. Radiological assessment showed no signs of loosening for both groups. Therefore, the Columbus knee system can be recommended for flexion angles up to 140∘.

  3. Apparent Skin Discoloration about the Knee Joint: A Rare Sequela of Metallosis after Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Narlaka Jayasekera

    2015-01-01

    Full Text Available Introduction. Metallosis is a phenomenon most commonly associated with hip replacement. However it can occur in any metallic implant subject to wear. Wear creates metal debris, which is deposited in the surrounding soft tissue. This leads to many local adverse reactions including, but not limited to, implant loosening/osteolysis, pain, and effusion. In the deeper joints, for example, the hip, metal deposits are mostly only seen intraoperatively. Case Study. A 74-year-old lady represented to orthopaedic outpatient clinic. Her principle complaint was skin discolouration, associated with pain and swelling over the left knee, on the background of a previous total knee replacement with a metal backed patella resurfacing six years. A plain radiograph revealed loosening of the patellar prosthesis. A diagnosis of metallosis was made; the patient underwent debridement of the stained soft tissue and primary revision of the prosthesis. She remained symptom-free five years after revision. Discussion. Metallosis results in metallic debris which causes tissue staining, often hidden within the soft tissue envelope of the hip, but more apparent in the knee. Metallosis may cause pain, effusion, and systemic symptoms because of raised levels of serum-metal ions. Surgical intervention with revision and debridement can have good functional results.

  4. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure.

    Science.gov (United States)

    Pagenstert, Geert; Hintermann, Beat

    2011-10-13

    Simultaneous osteoarthritis (OA) of the ankle joint complicates primary total knee arthroplasty (TKA). In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA) during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week) and hospital stay (12 days) of this special patient was markedly reduced compared to the usual course of separate TJA. Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  5. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure

    Directory of Open Access Journals (Sweden)

    Hintermann Beat

    2011-10-01

    Full Text Available Abstract Background Simultaneous osteoarthritis (OA of the ankle joint complicates primary total knee arthroplasty (TKA. In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. Case presentation We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week and hospital stay (12 days of this special patient was markedly reduced compared to the usual course of separate TJA. Conclusions Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  6. [Mini-subvastus approach for total knee replacement].

    Science.gov (United States)

    Halder, Andreas; Beier, Alexander; Neumann, Wolfram

    2009-03-01

    Total knee replacement in minimally invasive technique without any trauma to the extensor apparatus and with soft-tissue-referenced bone resections. Only the subvastus approach preserves the integrity of the extensor apparatus and has therefore been modified to become a minimally invasive technique with a shorter skin incision and lateralization instead of eversion of the patella. Soft-tissue balancing is done through this direct anterior approach. Mild to moderate varus osteoarthritis of the knee up to 15 degrees of malalignment, mild and passively correctable valgus osteoarthritis of the knee up to 10 degrees of malalignment. Severe, contract varus osteoarthritis of the knee, severe and moderate, contract valgus osteoarthritis of the knee, severe obesity, exceptionally muscular patients, decreased skin perfusion. Central skin incision from the superior pole of the patella to the tibial tubercle. Exposure of the medial retinaculum and mobilization of the vastus medialis muscle subcutaneously. Incision of the medial retinaculum and blunt separation of the vastus medialis muscle from the intermuscular septum. Lateralization of the patella and flexion of the knee joint. Resection of the tibia perpendicular to the diaphysis. Adjustment of the anteroposterior (AP) resection block at the level of the anterior femoral cortex and of rotation by applying equal tension to the collateral ligaments. Balancing of soft-tissue tension in flexion gap by release, if necessary. After AP resection fixation of distal resection block in planned valgus angle. Balancing of soft-tissue tension in extension gap by release, if necessary. After distal femur resection facet resection, adaptation of posterior femoral condyles, and implantation of prosthesis. Check on stability and range of motion. Wound closure. Full weight bearing from the 1st postoperative day, CPM (continuous passive motion) with up to 90 degrees flexion with peridural anesthesia as tolerated, stair climbing starting on

  7. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement

    Science.gov (United States)

    Rasnick, Robert; Standifird, Tyler; Reinbolt, Jeffrey A.; Cates, Harold E.

    2016-01-01

    Total knee replacement (TKR) is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF) and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (pknee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups. PMID:27258086

  8. [Partial replacement of the knee joint with patient-specific instruments and implants (ConforMIS iUni, iDuo)].

    Science.gov (United States)

    Beckmann, J; Steinert, A; Zilkens, C; Zeh, A; Schnurr, C; Schmitt-Sody, M; Gebauer, M

    2016-04-01

    Knee arthroplasty is a successful standard procedure in orthopedic surgery; however, approximately 20 % of patients are dissatisfied with the clinical results as they suffer pain and can no longer achieve the presurgery level of activity. According to the literature the reasons are inexact fitting of the prosthesis or too few anatomically formed implants resulting in less physiological kinematics of the knee joint. Reducing the number of dissatisfied patients and the corresponding number of revisions is an important goal considering the increasing need for artificial joints. In this context, patient-specific knee implants are an obvious alternative to conventional implants. For the first time implants are now matched to the individual bone and not vice versa to achieve the best possible individual situation and geometry and more structures (e.g. ligaments and bone) are preserved or only those structures are replaced which were actually destroyed by arthrosis. According to the authors view, this represents an optimal and pioneering addition to conventional implants. Patient-specific implants and the instruments needed for correct alignment and fitting can be manufactured by virtual 3D reconstruction and 3D printing based on computed tomography (CT) scans. The portfolio covers medial as well as lateral unicondylar implants, medial as well as lateral bicompartmental implants (femorotibial and patellofemoral compartments) and cruciate ligament-preserving as well as cruciate ligament-substituting total knee replacements; however, it must be explicitly emphasized that the literature is sparse and no long-term data are available.

  9. An energy harvesting converter to power sensorized total human knee prosthesis

    International Nuclear Information System (INIS)

    Luciano, V; Sardini, E; Serpelloni, M; Baronio, G

    2014-01-01

    Monitoring the internal loads acting in a total knee prosthesis (TKP) is fundamental aspect to improve their design. One of the main benefits of this improvement is the longer duration of the tibial inserts. In this work, an electromagnetic energy harvesting system, which is implantable in a TKP, is presented. This is conceived for powering a future implantable system that is able to monitor the loads (and, possibly, other parameters) that could influence the working conditions of a TKP in real-time. The energy harvesting system (EHS) is composed of two series of NdFeB magnets, positioned into each condyle, and a coil that is placed in a pin of the tibial insert and connected to an implantable power management circuit. The magnetic flux variation and the induced voltage are generated by the knee's motion. A TKP prototype has been realized in order to reproduce the knee mechanics and to test the EHS performance. In the present work, the experimental results are obtained by adopting a resistive load of 2.2 kΩ, in order to simulate a real implanted autonomous system with a current consumption of 850 µA and voltage of 2 V. The tests showed that, after 7 to 30 s of walking with a gait cycle frequency of about 1.0 Hz, the EHS can generate an energy of about 70 μJ, guaranteeing a voltage between 2 and 1.4 V every 7.6 s. With this prototype we can verify that it is possible to power for 16 ms a circuit having a power consumption of 1.7 mW every 7.6 s. The proposed generator is a viable solution to power an implanted electronic system that is conceived for measuring and transmitting the TKP load parameters. (paper)

  10. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

    Science.gov (United States)

    Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian

    2008-03-01

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all criteria for optimal implant alignment, 16 cases (32%) in the conventional cohort and 31

  11. Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.

    Science.gov (United States)

    Turger, Anke; Köhler, Jens; Denkena, Berend; Correa, Tomas A; Becher, Christoph; Hurschler, Christof

    2013-08-29

    Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.

  12. Total knee arthroplasty with computer-assisted navigation: an analysis of 200 cases,

    Directory of Open Access Journals (Sweden)

    Marcus Vinicius Malheiros Luzo

    2014-04-01

    Full Text Available OBJECTIVE: to evaluate the results from surgery with computer-assisted navigation in cases of total knee arthroplasty.METHOD: a total of 196 patients who underwent total knee arthroplasty with computer-assisted navigation were evaluated. The extension and flexion spaces (gaps were evaluated during the operation and the alignment after the operation was assessed. The Knee Society Score (KSS questionnaire for assessing patient's function was applied preoperatively and postoperatively after a mean follow-up of 22 months.RESULTS: in all, 86.7% of the patients presented good alignment of the mechanical axis (less than 3◦ of varus or valgus in relation to the mechanical axis and 96.4% of the patients presented balanced flexion and extension gaps. Before the operation, 97% of the patients presented poor or insufficient KSS, but after the operation, 77.6% presented good or excellent KSS.CONCLUSION: the navigation system made it possible to achieve aligned and balanced implants, with notable functional improvement among the patients. It was found to be useful in assessing, understanding and improving knowledge in relation to performing arthroplasty procedures.

  13. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement.

    Directory of Open Access Journals (Sweden)

    Robert Rasnick

    Full Text Available Total knee replacement (TKR is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (p<0.05. No differences were observed for peak joint compressive forces between groups. Some muscle force compensatory strategies appear to be present in both the loading and push-off phases. Evidence from knee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups.

  14. Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    Science.gov (United States)

    Murr, L E; Amato, K N; Li, S J; Tian, Y X; Cheng, X Y; Gaytan, S M; Martinez, E; Shindo, P W; Medina, F; Wicker, R B

    2011-10-01

    Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 μm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. CONTEMPORARY VIEW ON COMPUTER NAVIGATION USING AT PRIMARY KNEE TOTAL REPLACEMENT (REVIEW

    Directory of Open Access Journals (Sweden)

    A. I. Petukhov

    2010-01-01

    Full Text Available The topical questions of optical computer navigation at knee total arthroplasty are widely covered. The indications, contraindication to use, using features and possible complications of this technique are listed. The analysis of literature data makes it clear that computer navigation assists in the accuracy of endoprosthesis implantation that may to decrease the rate of revision surgeries in future.

  16. Patients Unicondylar Knee Replacement vs. Total Knee Replacement

    OpenAIRE

    Hedra Eskander

    2017-01-01

    The aim of this review article is to analyse the clinical effectiveness of total knee replacement (TKR) compared to unicondylar knee replacement (UKR) on patients. In terms of survival rates, revision rates and postoperative complications. The keywords used were: knee arthroplasty. Nearly three thousand articles were found on 25 August 2016. Of those, only twenty-five were selected and reviewed because they were strictly focused on the topic of this article. Compared with those who have TKR, ...

  17. Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements.

    Science.gov (United States)

    Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R; Izant, Timothy H; Cleary, Richard J

    2014-03-01

    Biological adaptation following placement of a total knee replacements (TKRs) affects peri-implant bone mineral density (BMD) and implant fixation. We quantified the proximal tibial bone strain and implant-bone micro-motion for functioning postmortem retrieved TKRs and assessed the strain/micro-motion relationships with chronological (donor age and time in service) and patient (body weight and BMD) factors. Twenty-two tibial constructs were functionally loaded to one body weight (60% medial/40% lateral), and the bone strains and tray/bone micro-motions were measured using a digital image correlation system. Donors with more time in service had higher bone strains (p = 0.044), but there was not a significant (p = 0.333) contribution from donor age. Donors with lower peri-implant BMD (p = 0.0039) and higher body weight (p = 0.0286) had higher bone strains. Long term implants (>11 years) had proximal bone strains 900 µϵ that were almost twice as high as short term (implants 570 µϵ. Micro-motion was greater for younger donors (p = 0.0161) and longer time in service (p = 0.0008). Increased bone strain with long term in vivo service could contribute to loosening of TKRs by failure of the tibial peri-implant bone. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Parametric analysis of electromechanical and fatigue performance of total knee replacement bearing with embedded piezoelectric transducers

    Science.gov (United States)

    Safaei, Mohsen; Meneghini, R. Michael; Anton, Steven R.

    2017-09-01

    Total knee arthroplasty is a common procedure in the United States; it has been estimated that about 4 million people are currently living with primary knee replacement in this country. Despite huge improvements in material properties, implant design, and surgical techniques, some implants fail a few years after surgery. A lack of information about in vivo kinetics of the knee prevents the establishment of a correlated intra- and postoperative loading pattern in knee implants. In this study, a conceptual design of an ultra high molecular weight (UHMW) knee bearing with embedded piezoelectric transducers is proposed, which is able to measure the reaction forces from knee motion as well as harvest energy to power embedded electronics. A simplified geometry consisting of a disk of UHMW with a single embedded piezoelectric ceramic is used in this work to study the general parametric trends of an instrumented knee bearing. A combined finite element and electromechanical modeling framework is employed to investigate the fatigue behavior of the instrumented bearing and the electromechanical performance of the embedded piezoelectric. The model is validated through experimental testing and utilized for further parametric studies. Parametric studies consist of the investigation of the effects of several dimensional and piezoelectric material parameters on the durability of the bearing and electrical output of the transducers. Among all the parameters, it is shown that adding large fillet radii results in noticeable improvement in the fatigue life of the bearing. Additionally, the design is highly sensitive to the depth of piezoelectric pocket. Finally, using PZT-5H piezoceramics, higher voltage and slightly enhanced fatigue life is achieved.

  19. Knee Flexion and Daily Activities in Patients following Total Knee Replacement: A Comparison with ISO Standard 14243

    Directory of Open Access Journals (Sweden)

    Markus A. Wimmer

    2015-01-01

    Full Text Available Walking is only one of many daily activities performed by patients following total knee replacement (TKR. The purpose of this study was to examine the hypotheses (a that subject activity characteristics are correlated with knee flexion range of motion (ROM and (b that there is a significant difference between the subject’s flexion/extension excursion throughout the day and the ISO specified input for knee wear testing. In order to characterize activity, the number of walking and stair stepping cycles, the time spent with dynamic and stationary activities, the number of activity sequences, and the knee flexion/extension excursion of 32 TKR subjects were collected during daily activity. Flexion/extension profiles were compared with the ISO 14243 simulator input profile using a level crossing classification algorithm. Subjects took an average of 3102 (range: 343–5857 walking cycles including 65 (range: 0–319 stair stepping cycles. Active and passive ROMs were positively correlated with stair walking time, stair step counts, and stair walking sequences. Simulated knee motion according to ISO showed significantly fewer level crossings at the flexion angles 20–40° and beyond 50° than those measured with the monitor. This suggests that implant wear testing protocols should contain more cycles and a variety of activities requiring higher knee flexion angles with incorporated resting/transition periods to account for the many activity sequences.

  20. Effect of compression therapy on knee swelling and pain after total knee arthroplasty

    DEFF Research Database (Denmark)

    Munk, Stig; Jensen, Niels J. F.; Andersen, Ida Bøgh

    2013-01-01

    PURPOSE: Knee swelling after total knee arthroplasty may impair postoperative mobilisation and training, and as medical elastic compression stockings are well tolerated and effective to prevent oedema, haematoma and postoperative pain after venous surgery, we wanted to study whether this effect...... could be transferred to total knee arthroplasty surgery reducing postoperative swelling and pain and thereby facilitating mobilisation and improving patient-reported knee function. METHODS: In a randomised controlled study, 88 patients were randomised to use either a medical elastic compression stocking...... or no stocking from the first postoperative day and the following 4 weeks after total knee arthroplasty. Outcome measures were knee, calf and ankle swelling, knee flexion, pain and patient-reported knee function. RESULTS: Seventy per cent of the swelling had occurred before application of the stocking the day...

  1. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    International Nuclear Information System (INIS)

    Rubello, D.; Caricasulo, D.; Borsato, N.; Chierichetti, F.; Zanco, P.; Ferlin, G.

    1996-01-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic 99m TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  2. Three-phase bone scan pattern in asymptomatic uncemented total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Rubello, D. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Caricasulo, D. [Orthopaedics Dept., General Hospital of Bassano del Grappa (Italy); Borsato, N. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Chierichetti, F. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Zanco, P. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy); Ferlin, G. [Nuclear Medicine-PET Center, General Hospital of Castelfranco Veneto (Italy)

    1996-10-01

    In this study we investigated the bone scan pattern in a homogeneous group of asymptomatic patients implanted with the same type of total knee arthroplasty (TKA) and with a minimum follow-up of 2 years. Twenty-nine patients (21 females, 8 males, mean age 62 years), with a total of 30 uncemented Hofmann TKAs, were entered in the study. The time interval from surgery to scintigraphic evaluation ranged from 2 to 4 years. Bone scan was performed using the three-phase technique and images were interpreted by visual analysis using a three-point scale for the dynamic and blood pool phases and a five-point scale for the bone phase. Areas of increased periprosthetic technetium-99m methylene diphosphonate (MDP) uptake were observed until 4 years after surgery. However, comparing the TKAs implanted 2, 3 and 4 years previously, a decreasing pattern in tracer uptake intensity was noted this being more evident in the femoral and lateral tibial components. In some cases, a persistently elevated tracer uptake, not exceeding a moderate grade, was found in the medial tibial component. In conclusion, increased periprosthetic {sup 99m}TC-MDP uptake is a common finding in asymptomatic uncemented Hofmann TKAs for a prolonged period after surgery, but the uptake intensity is generally mild or moderate and shows a characteristic decreasing pattern over time. Furthermore, in contrast with other types of asymptomatic knee implants previously investigated, no case of high or very high bone uptake was recorded with this type of implant. We may speculate that scintigraphic parameters of normality, and pathology, should be determined for each type of TKA. It is likely that, with the uncemented Hofmann TKA, a high or very high tracer uptake or a progressive increase in the uptake intensity is suggestive of the presence of complications. (orig.)

  3. Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin

    2017-06-01

    Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Randomised controlled trial of extraarticular gold bead implantation for treatment of knee osteoarthritis: a pilot study

    DEFF Research Database (Denmark)

    Nejrup, Kirsten; Olivarius, Niels de Fine; Jacobsen, Judith L.

    2008-01-01

    The primary objective of this double-blind, randomised, controlled trial was to determine if implanting gold beads at five acupuncture points around the knee joint improves 1-year outcomes for patients with osteoarthritis (OA) of the knee. Participants were 43 adults aged 18-80 years with pain...... and stiffness from non-specific OA of the knee for over a year. The intervention was blinded implantation of gold beads at five acupuncture points around the affected knee through a hypodermic needle, or needle insertion alone. Primary outcome measures were knee pain, stiffness and function assessed...... acupuncture had greater relative improvements in self-assessed outcomes. The treatment was well tolerated. This 1-year pilot study indicates that extraarticular gold bead implantation is a promising treatment modality for patients with OA of the knee. The new treatment should be tested in a larger trial...

  5. Placing a price on medical device innovation: the example of total knee arthroplasty.

    Directory of Open Access Journals (Sweden)

    Lisa G Suter

    Full Text Available BACKGROUND: Total knee arthroplasty (TKA is common, effective, and cost-effective. Innovative implants promising reduced long-term failure at increased cost are under continual development. We sought to define the implant cost and performance thresholds under which innovative TKA implants are cost-effective. METHODS: We performed a cost-effectiveness analysis using a validated, published computer simulation model of knee osteoarthritis. Model inputs were derived using published literature, Medicare claims, and National Health and Nutrition Examination Survey data. We compared projected TKA implant survival, quality-adjusted life expectancy (QALE, lifetime costs, and cost-effectiveness (incremental cost-effectiveness ratios or ICERs of standard versus innovative TKA implants. We assumed innovative implants offered 5-70% decreased long-term TKA failure rates at costs 20-400% increased above standard implants. We examined the impact of patient age, comorbidity, and potential increases in short-term failure on innovative implant cost-effectiveness. RESULTS: Implants offering ≥50% decrease in long-term TKA failure at ≤50% increased cost offered ICERs <$100,000 regardless of age or baseline comorbidity. An implant offering a 20% decrease in long-term failure at 50% increased cost provided ICERs <$150,000 per QALY gained only among healthy 50-59-year-olds. Increasing short-term failure, consistent with recent device failures, reduced cost-effectiveness across all groups. Increasing the baseline likelihood of long-term TKA failure among younger, healthier and more active individuals further enhanced innovative implant cost-effectiveness among younger patients. CONCLUSIONS: Innovative implants must decrease actual TKA failure, not just radiographic wear, by 50-55% or more over standard implants to be broadly cost-effective. Comorbidity and remaining life span significantly affect innovative implant cost-effectiveness and should be considered in the

  6. In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty.

    Science.gov (United States)

    Guan, Shanyuanye; Gray, Hans A; Schache, Anthony G; Feller, Julian; de Steiger, Richard; Pandy, Marcus G

    2017-08-01

    No data are available to describe six-degree-of-freedom (6-DOF) knee-joint kinematics for one complete cycle of overground walking following total knee arthroplasty (TKA). The aims of this study were firstly, to measure 6-DOF knee-joint kinematics and condylar motion for overground walking following TKA; and secondly, to determine whether such data differed between overground and treadmill gait when participants walked at the same speed during both tasks. A unique mobile biplane X-ray imaging system enabled accurate measurement of 6-DOF TKA knee kinematics during overground walking by simultaneously tracking and imaging the joint. The largest rotations occurred for flexion-extension and internal-external rotation whereas the largest translations were associated with joint distraction and anterior-posterior drawer. Strong associations were found between flexion-extension and adduction-abduction (R 2  = 0.92), joint distraction (R 2  = 1.00), and anterior-posterior translation (R 2  = 0.77), providing evidence of kinematic coupling in the TKA knee. Although the measured kinematic profiles for overground walking were grossly similar to those for treadmill walking, several statistically significant differences were observed between the two conditions with respect to temporo-spatial parameters, 6-DOF knee-joint kinematics, and condylar contact locations and sliding. Thus, caution is advised when making recommendations regarding knee implant performance based on treadmill-measured knee-joint kinematic data. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1634-1643, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study.

    Science.gov (United States)

    Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2012-08-01

    To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.

  8. Gait analysis of patients with an off-the-shelf total knee replacement versus customized bi-compartmental knee replacement.

    Science.gov (United States)

    Wang, Henry; Foster, Jonathan; Franksen, Natasha; Estes, Jill; Rolston, Lindsey

    2018-04-01

    Newer TKR designs have been introduced to the market with the aim of overcoming common sizing problems with older TKR designs. Furthermore, since a sizable percentage of patients with OA present with disease limited to the medial/lateral knee compartment in addition to the patellofemoral joint, for whom, a customized bi-compartmental knee replacement (BKR) is available as a treatment option. To date, there is very little information regarding knee strength and mechanics during gait for patients implanted with these modern TKR and BKR designs. The purpose of the study was to evaluate knee strength and mechanics during walking for patients with either a modern off the shelf TKR or a customized BKR and compare these findings to a cohort of healthy controls. Twelve healthy controls, eight BKR, and nine TKR patients participated in the study. Maximal isometric knee strength was evaluated. 3D kinematic and kinetic analyses were conducted for level walking. The TKR knee exhibited less peak extensor torque when compared to, both the BKR and control limbs (p < 0.05). The TKR knee had less extensor moment at stance than both the BKR and control knees (p < 0.05). Both the BKR and control knees displayed larger internal rotation at stance than that of the TKR knee (p < 0.05). This study suggests that, for patients that exhibit isolated OA of the tibiofemoral joint, using a customized BKR implant is a viable treatment option and may contribute to superior mechanical advantages.

  9. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties.

    Science.gov (United States)

    Martin, Audrey J; Seagers, Kirsten A; Van Citters, Douglas W

    2017-07-01

    Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Bridging the osteoarthritis treatment gap with the KineSpring Knee Implant System: early evidence in 100 patients with 1-year minimum follow-up

    Directory of Open Access Journals (Sweden)

    London NJ

    2013-09-01

    Full Text Available Nicholas J London,1 Jon Smith,2 Larry E Miller,3,4 Jon E Block4 1Department of Orthopaedic Surgery, Harrogate District Foundation Trust, Harrogate, UK; 2The Mid Yorkshire Hospitals NHS Trust, Yorkshire, UK; 3Miller Scientific Consulting, Arden, NC, USA; 4The Jon Block Group, San Francisco, CA, USA Abstract: Almost 4 million Americans are within the knee osteoarthritis (OA treatment gap, the period from unsuccessful exhaustion of conservative treatment to major surgical intervention. New treatment alternatives for symptomatic knee OA are greatly needed. The purpose of this report was to assess outcomes of a joint-unloading implant (KineSpring® Knee Implant System in patients with symptomatic medial knee OA. A total of 100 patients enrolled in three clinical trials were treated with the KineSpring System and followed for a minimum of 1 year. All devices were successfully implanted and activated, with no operative complications. Knee pain severity improved 60% (P < 0.001 at 1 year, with 76% of patients reporting a minimum 30% improvement in pain severity. All Western Ontario and McMaster Universities Arthritis Index (WOMAC subscores significantly improved at 1 year, with a 56% improvement in pain, 57% improvement in function, and a 39% improvement in stiffness (all P < 0.001. The percentage of patients experiencing a minimum 20% improvement in WOMAC subscores was 74% for pain, 83% for function, and 67% for stiffness. During follow-up, six (6% patients required additional surgery, including four total knee arthroplasties and two high tibial osteotomies. The KineSpring System effectively bridges the treatment gap between failed conservative care and surgical joint-modifying procedures. Keywords: implant, KineSpring, knee, medial, osteoarthritis, unloading

  11. Opportunities in Total Knee Arthroplasty: Worldwide Surgeons' Perspective.

    Science.gov (United States)

    Dunbar, Michael; Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Martinez, Nick; Bhowmik-Stoker, Manoshi; Mont, Michael A

    2017-07-25

    This study surveyed a group of US and international orthopaedic surgeons to prioritize areas of improvement in primary total knee arthroplasty (TKA). Specifically, we assessed surgeon responses regarding the top five areas of TKA needing improvement; which were stratified by: a) US surgeons, b) international surgeons, c) US surgeons' implant-brand-loyalty, and d) surgeons' years of experience and case volume. Four hundred and eighteen surgeons who were board-certified, in practice for at least two years, spent 60% of their time in clinical practice, and performed a minimum of 25 lower extremity joint arthroplasties per year were surveyed. They chose the top five areas (among 17) needing improvement for TKA. Results were stratified by surgeons' location (US and international), implant-brand-loyalty, years of experience, and case volume. Functional outcomes was the top identified area for improvement (US 63% and international 71%), followed by brand loyalty (Company I 68%, other brand 59%, and multi-brand/no loyalty 66%), years of experience (early-career 64%, mid-career 63%, and late-career 75%) and case volume (low-volume 69%, mid-volume 60%, and high-volume 71%). Following this was costs for US surgeons (47%) and implant survivorship for international surgeons (57%). While costs were the next highest area for specific Company-loyal surgeons (57%), implant survivorship was the next highest area for the other two cohorts. Implant survivorship was the second most important area of improvement regardless of years of experience and for low- and mid-volume surgeons. Surgeons identified functional outcomes as the most important area needing improvement. Cost of implants was more important for American as compared to international surgeons.

  12. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study

    DEFF Research Database (Denmark)

    Holm, Bente; Husted, Henrik; Kehlet, Henrik

    2012-01-01

    Objective: To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty.Design: A prospective, single-blinded, randomized, cross-over study.Setting: A fast-track orthopaedic arthroplasty unit at a university hospital.......Participants: Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty.Interventions: The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30...... minutes of elbow icing (control treatment). The order of treatments was randomized.Main outcome measures: Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments...

  13. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    OpenAIRE

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-01-01

    Abstract Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which sim...

  14. Comparison of robot surgery modular and total knee arthroplasty kinematics.

    Science.gov (United States)

    Yildirim, Gokce; Fernandez-Madrid, Ivan; Schwarzkopf, Ran; Walker, Peter S; Karia, Raj

    2014-04-01

    The kinematics of seven knee specimens were measured from 0 to 120 degrees flexion using an up-and-down crouching machine. Motion was characterized by the positions of the centers of the lateral and medial femoral condyles in the anterior-posterior direction relative to a fixed tibia. A modular unicompartmental knee, trochlea flange, and patella resurfacing (multicompartmental knee [MCK] system) were implanted using a surgeon-interactive robot system that provided accurate surface matching. The MCK was tested, followed by standard cruciate retaining (CR) and posterior stabilized (PS) knees. The motion of the MCK was close to anatomic, especially on the medial side, in contrast to the CR and PS knees that showed abnormal motion features. Such a modular knee system, accurately inserted, has the potential for close to normal function in clinical application. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models

    NARCIS (Netherlands)

    Berahmani, Sanaz; Janssen, Dennis; Verdonschot, Nico

    2017-01-01

    It is essential to calculate micromotions at the bone-implant interface of an uncemented femoral total knee replacement (TKR) using a reliable computational model. In the current study, experimental measurements of micromotions were compared with predicted micromotions by Finite Element Analysis

  16. Gel-type autologous chondrocyte (Chondron™ implantation for treatment of articular cartilage defects of the knee

    Directory of Open Access Journals (Sweden)

    Chun Chung-Woo

    2010-05-01

    Full Text Available Abstract Background Gel-type autologous chondrocyte (Chondron™ implantations have been used for several years without using periosteum or membrane. This study involves evaluations of the clinical results of Chondron™ at many clinical centers at various time points during the postoperative patient follow-up. Methods Data from 98 patients with articular cartilage injury of the knee joint and who underwent Chondron™ implantation at ten Korean hospitals between January 2005 and November 2008, were included and were divided into two groups based on the patient follow-up period, i.e. 13~24-month follow-up and greater than 25-month follow-up. The telephone Knee Society Score obtained during telephone interviews with patients, was used as the evaluation tool. Results On the tKSS-A (telephone Knee Society Score-A, the score improved from 43.52 ± 20.20 to 89.71 ± 13.69 (P Conclusion Gel-type autologous chondrocyte implantation for chondral knee defects appears to be a safe and effective method for both decreasing pain and improving knee function.

  17. The role of surgeon volume on patient outcome in total knee arthroplasty: a systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Lau Rick L

    2012-12-01

    Full Text Available Abstract Background A number of factors have been identified as influencing total knee arthroplasty outcomes, including patient factors such as gender and medical comorbidity, technical factors such as alignment of the prosthesis, and provider factors such as hospital and surgeon procedure volumes. Recently, strategies aimed at optimizing provider factors have been proposed, including regionalization of total joint arthroplasty to higher volume centers, and adoption of volume standards. To contribute to the discussions concerning the optimization of provider factors and proposals to regionalize total knee arthroplasty practices, we undertook a systematic review to investigate the association between surgeon volume and primary total knee arthroplasty outcomes. Methods We performed a systematic review examining the association between surgeon volume and primary knee arthroplasty outcomes. To be included in the review, the study population had to include patients undergoing primary total knee arthroplasty. Studies had to report on the association between surgeon volume and primary total knee arthroplasty outcomes, including perioperative mortality and morbidity, patient-reported outcomes, or total knee arthroplasty implant survivorship. There were no restrictions placed on study design or language. Results Studies were variable in defining surgeon volume (‘low’: 5 to >70 total knee arthroplasty per year. Mortality rate, survivorship and thromboembolic events were not found to be associated with surgeon volume. We found a significant association between low surgeon volume and higher rate of infection (0.26% - 2.8% higher, procedure time (165 min versus 135 min, longer length of stay (0.4 - 2.13 days longer, transfusion rate (13% versus 4%, and worse patient reported outcomes. Conclusions Findings suggest a trend towards better outcomes for higher volume surgeons, but results must be interpreted with caution.

  18. Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement - A finite element analysis.

    Science.gov (United States)

    Moewis, Philippe; Checa, Sara; Kutzner, Ines; Hommel, Hagen; Duda, Georg N

    2018-01-01

    Mechanical and kinematical aligning techniques are the usual positioning methods during total knee arthroplasty. However, alteration of the physiological joint line and unbalanced medio-lateral load distribution are considered disadvantages in the mechanical and kinematical techniques, respectively. The aim of this study was to analyse the influence of the joint line on the strain and stress distributions in an implanted knee and their sensitivity to rotational mal-alignment. Finite element calculations were conducted to analyse the stresses in the PE-Inlay and the mechanical strains at the bone side of the tibia component-tibia bone interface during normal positioning of the components and internal and external mal-rotation of the tibial component. Two designs were included, a horizontal and a physiological implant. The loading conditions are based on internal knee joint loads during walking. A medialization of the stresses on the PE-Inlay was observed in the physiological implant in a normal position, accompanied by higher stresses in the mal-rotated positions. Within the tibia component-tibia bone interface, similar strain distributions were observed in both implant geometries in the normal position. However, a medialization of the strains was observed in the physiological implant in both mal-rotated conditions with greater bone volume affected by higher strains. Although evident changes due to mal-rotation were observed, the stresses do not suggest a local plastic deformation of the PE-Inlay. The strains values within most of the tibia component-tibia bone interface were in the physiological strain zone and no significant bone changes would be expected. The physiological cut on the articular aspect showed no detrimental effect compared to the horizontal implant.

  19. Surgical waste audit of 5 total knee arthroplasties.

    Science.gov (United States)

    Stall, Nathan M; Kagoma, Yoan M; Bondy, Jennifer N; Naudie, Douglas

    2013-04-01

    Operating rooms (ORs) are estimated to generate up to one-third of hospital waste. At the London Health Sciences Centre, prosthetics and implants represent 17% of the institution's ecological footprint. To investigate waste production associated with total knee arthroplasties (TKAs), we performed a surgical waste audit to gauge the environmental impact of this procedure and generate strategies to improve waste management. We conducted a waste audit of 5 primary TKAs performed by a single surgeon in February 2010. Waste was categorized into 6 streams: regular solid waste, recyclable plastics, biohazard waste, laundered linens, sharps and blue sterile wrap. Volume and weight of each stream was quantified. We used Canadian Joint Replacement Registry data (2008-2009) to estimate annual weight and volume totals of waste from all TKAs performed in Canada. The average surgical waste (excluding laundered linens) per TKA was 13.3 kg, of which 8.6 kg (64.5%) was normal solid waste, 2.5 kg (19.2%) was biohazard waste, 1.6 kg (12.1%) was blue sterile wrap, 0.3 kg (2.2%) was recyclables and 0.3 kg (2.2%) was sharps. Plastic wrappers, disposable surgical linens and personal protective equipment contributed considerably to total waste. We estimated that landfill waste from all 47 429 TKAs performed in Canada in 2008-2009 was 407 889 kg by weight and 15 272 m3 by volume. Total knee arthroplasties produce substantial amounts of surgical waste. Environmentally friendly surgical products and waste management strategies may allow ORs to reduce the negative impacts of waste production without compromising patient care. Level IV, case series.

  20. The use of adaptive equipment following total knee replacement

    OpenAIRE

    McNaught, Jamie; Paul, Lorna

    2015-01-01

    Introduction: This study evaluates the need for adaptive equipment following total knee replacement. There are no recent studies to guide occupational therapists in the optimum time adaptive equipment is required following total knee replacement.\\ud \\ud Method: A non-experimental, concurrent mixed methods approach was used. The study population was patients attending for total knee replacement at a large general hospital. Outcome measures were the Oxford Knee Score, the United Kingdom Functio...

  1. Recurrent hemarthrosis after total knee arthroplasty

    NARCIS (Netherlands)

    Rukavina, A.; Kerkhoffs, G.M.M.J.; Schneider, P.; Kuster, M.S.

    2010-01-01

    This report describes a case of spontaneous recurrent hemarthrosis of the knee that presented 4 weeks after total knee arthroplasty. Femoral arteriography showed a false aneurysm of a branch of the inferior lateral geniculate artery. Therapeutic embolization of the arterial branch was performed

  2. Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.

    Science.gov (United States)

    Saffo, Zaid; Ognjan, Anthony

    2016-01-01

    The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a

  3. Medium-term evaluation of total knee arthroplasty without patellar replacement

    Directory of Open Access Journals (Sweden)

    José Wanderley Vasconcelos

    2013-06-01

    Full Text Available OBJECTIVE: To mid-term evaluate patients who were submitted to total knee arthroplasty without patellar resurfacing. METHODS: It was realized a retrospective cross-sectional study of patients who were submitted to total knee arthroplasty without patellar resurfacing. In all patients clinical examination was done based on the protocol of the Knee Society Scoring System, which assessed pain, range of motion, stability, contraction, knee alignment and function, and radiological evaluation. RESULTS: A total of 36 patients were evaluated. Of these, 07 were operated only on left knee, 12 only on right knee and 17 were operated bilaterally, totaling 53 knees. Ages ranged from 26 to 84 years. Of the 53 knees evaluated, 33 (62.26% had no pain. The maximum flexion range of motion averaged 104.7°. No knee had difficulty in active extension. As to the alignment for anatomical axis twelve knees (22.64% showed deviation between 0° and 4° varus. Thirty-nine (75.49% knees showed pace without restriction and the femorotibial angle ranged between 3° varus and 13° valgus with an average of 5° valgus. The patellar index ranged from 0.2 to 1.1. CONCLUSION: Total knee arthroplasty whitout patellar resurfacing provides good results in mid-term evaluation.

  4. 3D in vivo femoro-tibial kinematics of tri-condylar total knee arthroplasty during kneeling activities.

    Science.gov (United States)

    Nakamura, Shinichiro; Sharma, Adrija; Kobayashi, Masahiko; Ito, Hiromu; Nakamura, Kenji; Zingde, Sumesh M; Nakamura, Takashi; Komistek, Richard D

    2014-01-01

    Kneeling position can serve as an important posture, providing stability and balance from a standing position to sitting on the floor or vice-versa. The purpose of the current study was to determine the kinematics during kneeling activities after subjects were implanted with a tri-condylar total knee arthroplasty. Kinematics was evaluated in 54 knees using fluoroscopy and a three-dimensional model fitting approach. The average knee flexion at before contact status, at complete contact and at maximum flexion was 98.1±9.0°, 107.2±6.7°, and 139.6±12.3°, respectively. On average, there was no gross anterior displacement from before contact status to complete contact. Only slight posterior rollback motion of both condyles from complete contact to maximum flexion was observed. Three of 39 (7.7%) knees experienced anterior movement of both condyles more than 2mm from before contact status to complete contact. Reverse rotation pattern from before contact status to complete contact and then normal rotation pattern from complete contact to maximum flexion were observed. Condylar lift-off greater than 1.0 mm was observed in 45 knees (83.3%). The presence of the ball-and-socket joint articulation provides sufficient antero-posterior stability in these designs to enable the patients to kneel safely without the incidence of any dislocation. This study suggests a safe implant design for kneeling. © 2013.

  5. Infection after total knee replacement: diagnosis and treatment

    Directory of Open Access Journals (Sweden)

    Lucio Honorio de Carvalho Junior

    2013-09-01

    Full Text Available Infection after total knee replacement (IATJ is a rare complication. It is associated with increased morbidity and mortality increasing the final costs. Gram positive coccus and Staphylococcus coagulase-negative and Staphylococcus aureus are the most common isolated germs (>50% of the cases. Conditions related to the patient, to the surgical procedure and even to the post op have been identified as risk factors to IATJ. Many complementary methods together with clinical symptoms are useful to a proper diagnosis. Treatment for IATJ must be individualized but generally is a combination of systemic antibiotic therapy and surgical treatment. Prosthesis exchange in one or two stages is the first choice procedure. Debridement with prosthesis retention is an option in acute cases with stable implants and antibiotic sensible germs.

  6. Better Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up

    Directory of Open Access Journals (Sweden)

    Ricardo Fernandez-Fernandez

    2015-01-01

    Full Text Available  Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship.    Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 knees who underwent knee replacement for osteoarthritis with a mean follow-up of 11.4 years (range: 8.8 to 12. The mean age was 70 years (range: 31 to 85. Knee replacements were stratified into two groups: 109 were younger than 70 years and 127 were older than 70 years (70 years of age is the mandatory retirement age. Results: There were no significant pre-operative differences between groups with regards to knee alignment, alpha or beta angles, knee score or function score. Fourteen implants were radiographically loose at last follow up visit. Groups were matched in terms of demographic data. We found that patients older than 70 years had significantly better mean survivorship at 12 years. (97% vs. 88%; P=0.010. Patients under 70 years presented with a higher rate of polyethylene wear which was further associated with radiolucent lines in the femur and tibia as well as the presence of osteolysis. There was also an association between migration and presence of osteolysis. Conclusions: Patients over 70 years old undergoing cemented total knee replacement for osteoarthritis showed better implant survivorship versus patients under 70 years old.

  7. Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study.

    Science.gov (United States)

    Singh, Avatar; Singh, Kanwar Kulwinder

    2017-09-01

    Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (ppain, and improved functionality.

  8. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty : A randomized controlled trial

    NARCIS (Netherlands)

    Van Hamersveld, Koen T.; Marang-Van De Mheen, Perla J.; Van Der Heide, Huub J.L.; Van Der Linden-Van Der Zwaag, Henrica M.J.; Valstar, E.R.; Nelissen, R.G.H.H.

    2018-01-01

    Background and purpose — Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component

  9. [Clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity].

    Science.gov (United States)

    Chen, Peng; Zeng, Min; Xie, Jie; Wang, Long; Su, Weiping; Hu, Yihe

    2016-09-28

    To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
 A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect.
 Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (Pclinical and function KSS scores showed that the improvement rate was 80%. 
 Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis combined with

  10. Variation in the cost of care for primary total knee arthroplasties.

    Science.gov (United States)

    Haas, Derek A; Kaplan, Robert S

    2017-03-01

    The study examined the cost variation across 29 high-volume US hospitals and their affiliated orthopaedic surgeons for delivering a primary total knee arthroplasty without major complicating conditions. The hospitals had similar patient demographics, and more than 80% of them had statistically-similar Medicare risk-adjusted readmission and complication rates. Hospital and physician personnel costs were calculated using time-driven activity-based costing. Consumable supply costs, such as the prosthetic implant, were calculated using purchase prices, and postacute care costs were measured using either internal costs or external claims as reported by each hospital. Despite having similar patient demographics and readmission and complication rates, the average cost of care for total knee arthroplasty across the hospitals varied by a factor of about 2 to 1. Even after adjusting for differences in internal labor cost rates, the hospital at the 90th percentile of cost spent about twice as much as the one at the 10th percentile of cost. The large variation in costs among sites suggests major and multiple opportunities to transfer knowledge about process and productivity improvements that lower costs while simultaneously maintaining or improving outcomes.

  11. Ertapenem Articulating Spacer for the Treatment of Polymicrobial Total Knee Arthroplasty Infection

    Directory of Open Access Journals (Sweden)

    Dragan Radoicic

    2016-01-01

    Full Text Available Introduction. Periprosthetic joint infections (PJIs are the primary cause of early failure of the total knee arthroplasty (TKA. Polymicrobial TKA infections are often associated with a higher risk of treatment failure. The aim of the study was to assess the efficacy of ertapenem loaded spacers in the treatment of polymicrobial PJI. Methods. There were 18 patients enrolled; nine patients with polymicrobial PJI treated with ertapenem loaded articulating spacers were compared to the group of 9 patients treated with vancomycin or ceftazidime loaded spacers. Results. Successful reimplantation with revision implants was possible in 66.67%. Ertapenem spacers were used in 6 cases in primary two-stage procedure and in 3 cases in secondary spacer exchange. Successful infection eradication was achieved in all cases; final reimplantation with revision knee arthroplasty implants was possible in 6 cases. Conclusion. Ertapenem can be successfully used as antimicrobial addition to the cement spacers in two-stage revision treatment of polymicrobial PJIs. However, this type of spacer may also be useful in the treatment of infections caused by monomicrobial extended spectrum beta-lactamases producing gram-negative bacilli. Further clinical studies are required to evaluate the efficacy and safety of ertapenem spacers in the treatment of polymicrobial and monomicrobial PJIs.

  12. Complications of fixed infrared emitters in computer-assisted total knee arthroplasties

    Directory of Open Access Journals (Sweden)

    Suárez-Vázquez Abelardo

    2007-07-01

    Full Text Available Abstract Background The first stage in the implant of a total knee arthroplasty with computer-assisted surgery is to fasten the emitters to the femur and the tibia. These trackers must be hard-fixed to the bone. The objectives of our study are to evaluate the technical problems and complications of these tracker-pins, the necessary time to fix them to the bone and the possible advantages of a new femoral-fixed tracker-pin. Methods Three hundred and sixty seven tracker-pins were used in one hundred and fifty one computer-assisted total knee replacements. A bicortical screw was used to fix the tracker to the tibia in all cases; in the femur, however, a bicortical tracker was used in 112 cases, while a new device (OrthoLock with percutaneous fixation pins was employed in the remaining 39. Results Technical problems related to the fixing of the trackers appeared in nine cases (2.5%. The mean surgery time to fix the tracker pin to the tibia was 3 minutes (range 2–7, and 5 minutes in the case of the femoral pin (range: 4–11, although with the new tool it was only three minutes (range 2–4 (p Conclusion The incidence of problems and complications with the fixing systems used in knee navigation is very small. The use of a new device with percutaneous pins facilitates the fixing of femoral trackers and decreases the time needed to place them.

  13. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (Pknee was corrected (Pknee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. RAPID KNEE-EXTENSIONS TO INCREASE QUADRICEPS MUSCLE ACTIVITY IN PATIENTS WITH TOTAL KNEE ARTHROPLASTY

    DEFF Research Database (Denmark)

    Husted, Rasmus Skov; Wilquin, Lousia; Jakobsen, Thomas Linding

    2017-01-01

    rapid knee-extensions were associated with greater voluntary quadriceps muscle activity during an experimental strength training session, compared to that elicited using slow knee-extensions. STUDY DESIGN: A randomized cross-over study. METHODS: Twenty-four patients (age 66.5) 4-8 weeks post total knee...... agonist muscle activity, especially if the exercise is conducted using rapid muscle contractions. PURPOSE: The purpose of this study was to examine if patients with total knee arthroplasty could perform rapid knee-extensions using a 10 RM load four to eight weeks after surgery, and the degree to which...... arthroplasty randomly performed one set of five rapid, and one set of five slow knee-extensions with the operated leg, using a load of their 10 repetition maximum, while surface electromyography recordings were obtained from the vastus medialis and lateralis of the quadriceps muscle. RESULTS: Data from 23...

  15. Rapid knee-extensions to increase quadriceps muscle activity in patients with total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Rasmus Skov; Wilquin, Lousia; Jakobsen, Thomas Linding

    2017-01-01

    rapid knee-extensions were associated with greater voluntary quadriceps muscle activity during an experimental strength training session, compared to that elicited using slow knee-extensions. STUDY DESIGN: A randomized cross-over study. METHODS: Twenty-four patients (age 66.5) 4-8 weeks post total knee...... agonist muscle activity, especially if the exercise is conducted using rapid muscle contractions. PURPOSE: The purpose of this study was to examine if patients with total knee arthroplasty could perform rapid knee-extensions using a 10 RM load four to eight weeks after surgery, and the degree to which...... arthroplasty randomly performed one set of five rapid, and one set of five slow knee-extensions with the operated leg, using a load of their 10 repetition maximum, while surface electromyography recordings were obtained from the vastus medialis and lateralis of the quadriceps muscle. RESULTS: Data from 23...

  16. Arthroplasty knee registry of Catalonia: What scientific evidence supports the implantation of our prosthesis?

    Science.gov (United States)

    Samaniego Alonso, R; Gaviria Parada, E; Pons Cabrafiga, M; Espallargues Carreras, M; Martinez Cruz, O

    2018-02-28

    In our environment, it is increasingly necessary to perform an activity based on scientific evidence and the field of prosthetic surgery should be governed by the same principles. The national arthroplasty registries allow us to obtain a large amount of data in order to evaluate this technique. The aim of our study is to analyse the scientific evidence that supports the primary total knee arthroplasties implanted in Catalonian public hospitals, based on the Arthoplasty Registry of Catalonia (RACat) MATERIAL AND METHODS: A review of the literature was carried out on knee prostheses (cruciate retaining, posterior stabilized, constricted and rotational) recorded in RACat between the period 2005-2013 in the following databases: Orthopedic Data Evaluation Panel, PubMed, TripDatabase and Google Scholar. The prostheses implanted in fewer than 10 units (1,358 prostheses corresponding to 62 models) were excluded. 41,947 prostheses (96.86%) were analysed out of 43,305 implanted, corresponding to 74 different models. In 13 models (n = 4,715) (11.24%) no clinical evidence to support their use was found. In the remaining 36 models (n = 13,609) (32.45%), level iv studies were the most predominant evidence. There was a significant number of implanted prostheses (11.24%) for which no clinical evidence was found. The number of models should be noted, 36 out of 110, with fewer than 10 units implanted. The use of arthroplasty registries has proved an extremely useful tool that allows us to analyse and draw conclusions in order to improve the efficiency of this surgical technique. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. The importance of bony impingement in restricting flexion after total knee arthroplasty: computer simulation model with clinical correlation.

    Science.gov (United States)

    Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D

    2012-10-01

    We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with 125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Severe Heterotopic Ossification following Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Alexander L. Dodds

    2014-01-01

    Full Text Available Although the incidence of minor heterotopic ossification is probably higher than what is usually expected, severe heterotopic ossification (HO is an extremely rare event following total knee replacement surgery. We present the case of a 66-year-old woman who initially had achieved an excellent range of motion following bilateral uncemented rotating platform total knee replacement, before presenting with pain and loss of range of motion at 2 months after surgery. Severe HO was diagnosed on X-rays. Treatment consisted of nonoperative measures only, including physiotherapy with hydrotherapy and anti-inflammatories. She eventually regained her range of motion when seen at 8 months after operation. This case illustrates that nonoperative treatment without the use of radiotherapy or surgery can be used to safely resolve stiffness caused by HO after total knee replacement.

  19. Ipsilateral stress fracture of the proximal fibula after total knee arthroplasty in a patient with severe valgus knee deformity on a background of Rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai

    Full Text Available Introduction: Previous studies have reported a lower extremity stress fracture after total knee arthroplasty (TKA. However, a fibular fracture after TKA is quite rare. We report a case of proximal fibula fracture after TKA in a patient with rheumatoid arthritis (RA. Presentation of case: A 45 year old woman with RA had severe knee and foot pain with an antalgic gait disturbance. There was a significant joint deformity in many of lower limb joints. Interval bilateral TKAs were performed two weeks apart. Right TKA was performed using a constraint-type prosthesis, through lateral parapatellar approach. Left TKA was performed using a posterior-stabilized (PS prosthesis through the more commonly employed, medial parapatellar approach. Seven weeks after the right TKA, the patient was found to have an atraumatic proximal fibular fracture. The fracture went on to heal conservatively. Discussion: The fracture was considered to have occurred after the TKA. The callus appeared eleven weeks after the TKA. The factors that contributed to the fracture were thought to be overload of the fragile bone secondarily to disuse osteopaenia, RA or potentially the significant valgus malalignment correction. The surgical approach, the implant or implantation or the persisting joint deformity, were thought to be contributing factors to the aetiology of the stress fracture. The resultant change in clinical outcome/course is outlined in this case report. Conclusion: A stress fracture of the proximal fibula has the potential in the aetiology of may cause other stress fractures, joint other instability, and/or malalignment of the total lower extremity. Keywords: Stress fracture, Insufficiency fracture, Total knee arthroplasty, Fibula fracture, Valgus deformity, Rheumatoid arthritis

  20. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    Science.gov (United States)

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  1. Knee and Ankle Arthroplasty in Hemophilia

    Directory of Open Access Journals (Sweden)

    Luigi Piero Solimeno

    2017-11-01

    Full Text Available Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described.

  2. OCCURRENCE OF EARLY KNEE ARTHROSIS FOLLOWING TOTAL MENISCECTOMIES IN YOUTH

    Directory of Open Access Journals (Sweden)

    Sasa Milenkovic

    2006-01-01

    Full Text Available The occurrence of early knee arthrosis following early total meniscectomy is a significant orthopedic, social and economical problem. Arthroscopic surgery shows the role and significance of the menisci for normal knee functioning. The outcome of 19 knee arthroscopies are presented; patients are of male sex, average age 39 (from 34 to 45. All patients underwent knee arthrotomy and total medial and lateral meniscectomy before the age of 25. All patients were active sportsmen. 12 arthroscopies of the right knee and 7 arthroscopies of the left one were done. In 13 patients, medial knee arthrosis following medial meniscectomy was found. One patient had lateral knee arthrosis and degeneration of the medial meniscus following lateral meniscectomy . The same patient had the total rupture of LCA. The remaining 5 patients had lateral knee arthrosis following lateral meniscectomy. One or more loose bodies of cartilaginous origin were found in 8 patients. All the operated patients had evident early signs of initial or progressive knee arthrosis confirmed or diagnosed arthroscopically. Knee arthroscopy in early arthroses following knee meniscectomies in youth can relieve the pain and slow down disease progression. A permanent solution to the problem is possible only with unicompartmental knee arthroplasty.

  3. Total Knee Arthroplasty Designed to Accommodate the Presence or Absence of the Posterior Cruciate Ligament

    Directory of Open Access Journals (Sweden)

    Melinda K. Harman

    2014-01-01

    Full Text Available Evidence for selecting the same total knee arthroplasty prosthesis whether the posterior cruciate ligament (PCL is retained or resected is rarely documented. This study reports prospective midterm clinical, radiographic, and functional outcomes of a fixed-bearing design implanted using two different surgical techniques. The PCL was completely retained in 116 knees and completely resected in 43 knees. For the entire cohort, clinical knee (96±7 and function (92±13 scores and radiographic outcomes were good to excellent for 84% of patients after 5–10 years in vivo. Range of motion averaged 124˚±9˚, with 126 knees exhibiting ≥120° flexion. Small differences in average knee flexion and function scores were noted, with the PCL-resected group exhibiting an average of 5° more flexion but an average function score that was 7 points lower compared to the PCL-retained group. Fluoroscopic analysis of 33 knees revealed stable tibiofemoral translations. This study demonstrates that a TKA articular design with progressive congruency in the lateral compartment can provide for femoral condyle rollback in maximal flexion activities and achieve good clinical and functional performance in patients with PCL-retained and PCL-resected TKA. This TKA design proved suitable for use with either surgical technique, providing surgeons with the choice of maintaining or sacrificing the PCL.

  4. Artroplastia total do joelho assistida por computador Computer-assisted knee total arthroplasty

    Directory of Open Access Journals (Sweden)

    Roberto Freire da Mota e Albuquerque

    2006-01-01

    Full Text Available Um dos avanços tecnológicos mais significativos da medicina atual é a cirurgia assistida por computador, sendo que na ortopedia uma das aplicações mais importantes dessa tecnologia é na artroplastia do joelho. A principal contribuição da cirurgia ortopédica assistida por computador (Computer Aided Orthopaedic Surgery’s - CAOS na artroplastia do joelho é o seu potencial em aprimorar a precisão da implantação das próteses e do alinhamento do membro operado contribuindo para a otimização e longevidade dos resultados. A navegação independente de imagens, baseada em referências anatômicas adquiridas durante o ato cirúrgico através de transmissores de raios infra-vermelho, tem sido a técnica preponderante na artroplastia do joelho. Utilizamos o sistema de navegação para artroplastia total do joelho "OrthoPilot" versão 2.2 para a colocação de 72 próteses de joelho "Search Evolution" da "Aesculap AG CO. KG" com ou sem estabilização posterior em uma série contínua. O objetivo foi aferir a precisão do alinhamento obtido com a navegação através de radiografias panorâmicas obtidas no período pós-operatório. Obtivemos um desvio médio do eixo mecânico nulo de 0,66º com desvio padrão de 0,7º, sendo que 98,6% dos joelhos ficaram dentro de uma margem de erro de 3º e 79,2% com erro inferior a 1º. Concluímos que o sistema é seguro e preciso, não adicionando morbidade à cirurgia convencional.One of the most significant technological advancements in current medicine is the computer-assisted surgery, which, for orthopaedics, one of the major uses of this technology is in knee arthroplasty. The main contribution provided by computer-assisted orthopaedic surgery (CAOS to knee arthroplasty is its potential to improve prosthesis implant precision and the operated limb alignment, contributing to results optimization and longevity. The image-independent navigation, based on anatomical references acquired during surgical

  5. Approach towards total knee arthroplasty in Brazil: cross-sectional study

    Directory of Open Access Journals (Sweden)

    Raul Frankllim de Carvalho Almeida

    Full Text Available CONTEXT AND OBJECTIVE: Total knee arthroplasty (TKA has evolved particularly since the 1970s, with improvements in implants and surgical instruments, and has thus become an effective intervention for treating knee arthrosis. Many studies have presented rates of satisfactory clinical and radiological results greater than 90%, from follow-ups of over ten years. Nevertheless, despite scientific evidence showing the efficacy of TKA, the approaches taken present controversies in certain respects. The objective of this study was to evaluate how the Brazilian orthopedists deal with TKA, with investigation of the main aspects of this procedure. DESIGN AND SETTING: Cross-sectional survey conducted during the 39th Brazilian Congress of Orthopedics and Traumatology, in São Paulo, Brazil, in November 2007. METHODS: We applied a questionnaire to orthopedists registered at the congress. The questionnaire was randomly distributed and participation was voluntary; 858 completed questionnaires were included in the analysis. RESULTS: Most of the Brazilian orthopedists were members of SBOT and worked in the southeastern region. They used imported cemented implants through an anterior access route centered on the patella, with replacement of the joint surface of the patella and preservation of the posterior cruciate ligament. They did not have experience with simultaneous bilateral TKA. Postoperatively, they used antibiotics and suction drains for 48 hours. There was no consensus regarding prophylaxis for venous thromboembolism or the frequency of the main complications. CONCLUSION: The majority of Brazilian orthopedists work in the southeastern region of the country and agree about the main aspects of the approaches towards TKA.

  6. Knee Pain during Strength Training Shortly following Fast-Track Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Thorborg, Kristian; Lunn, Troels Haxholdt

    2014-01-01

    BACKGROUND: Loading and contraction failure (muscular exhaustion) are strength training variables known to influence neural activation of the exercising muscle in healthy subjects, which may help reduce neural inhibition of the quadriceps muscle following total knee arthroplasty (TKA). It is unkn......BACKGROUND: Loading and contraction failure (muscular exhaustion) are strength training variables known to influence neural activation of the exercising muscle in healthy subjects, which may help reduce neural inhibition of the quadriceps muscle following total knee arthroplasty (TKA......). It is unknown how these exercise variables influence knee pain after TKA. OBJECTIVE: To investigate the effect of loading and contraction failure on knee pain during strength training, shortly following TKA. DESIGN: Cross-sectional study. SETTING: Consecutive sample of patients from the Copenhagen area, Denmark...... TKA. However, only the increase in pain during repetitions to contraction failure exceeded that defined as clinically relevant, and was very short-lived. TRIAL REGISTRATION: ClinicalTrials.gov NCT01729520....

  7. Outcomes of Total Knee Arthroplasty in Patients With Poliomyelitis.

    Science.gov (United States)

    Gan, Zhi-Wei Jonathan; Pang, Hee Nee

    2016-11-01

    We report our experience with outcomes of poliomyelitis in the Asian population. Sixteen total knee replacements in 14 patients with polio-affected knees were followed up for at least 18 months. Follow-up assessment included scoring with the American Knee Society Score (AKSS), Oxford knee score, and Short Form 36 Health Survey scores. The mean AKSS improved from 25.59 preoperatively to 82.94 at 24 months, with greater improvement in the knee score. The mean Oxford knee score improved from 40.82 preoperatively to 20.53 at 24 months. The mean AKSS pain score rose from 2.35 to 47.66 at 24 months. The Short Form 36 Health Survey physical functioning and bodily pain scores improved for all patients. Primary total knee arthroplasty of poliomyelitis-affected limbs shows good outcomes, improving quality of life, and decreasing pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    Science.gov (United States)

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. OUTCOMES REVIEW OF TOTAL KNEE REPLACEMENT WITH GENESIS II TOTAL KNEE SYSTEM: AUSTRALIAN ORTHOPAEDIC ASSOCIATION NATIONAL JOINT REPLACEMENT REGISTRY DATA

    Directory of Open Access Journals (Sweden)

    N. L. Logvinov

    2014-01-01

    Full Text Available ABSTRACT. The goal of the article was to review Genesis II Total Knee System use according to AoA NJRR report. Genesis II has been widely used in Russian Federation since 1996. The AoA NJRR report was studied in order to learn connection between number of revision procedures and surgeon’s skills or type of the System, adequate choice among cemented, cementless and hybrid fixation, number of surgeries using Genesis II Total Knee System annually, average revision rate for Genesis II and early cumulative revision rate.CONCLUSION. The systematic study of AoA NJRR allows us to make a conclusion that cemented fixation of Genesis II Total Knee System is mostly effective, and this fact is confirmed by domestic experience. 

  10. Autograft reconstructions for bone defects in primary total knee replacement in severe varus knees

    Directory of Open Access Journals (Sweden)

    Yatinder Kharbanda

    2014-01-01

    Full Text Available Background: Large posteromedial defects encountered in severe varus knees during primary total knee arthroplasty can be treated by cementoplasty, structural bone grafts or metallic wedges. The option is selected depending upon the size of the defect. We studied the outcome of autograft (structural and impaction bone grafting reconstruction of medial tibial bone defects encountered during primary total knee replacement in severe varus knees. Materials and Methods: Out of 675 primary varus knees operated, bone defects in proximal tibia were encountered in 54 knees. Posteromedial defects involving 25-40% of the tibial condyle cut surface and measuring more than 5 mm in depth were grafted using a structural graft obtained from cut distal femur or proximal tibia in 48 knees. For larger, peripheral uncontained vertical defects in six cases, measuring >25 mm in depth and involving >40% cut surface of proximal tibial condyle, impaction bone grafting with a mesh support was used. Results: Bone grafts incorporated in 54 knees in 6 months. There was no graft collapse or stress fractures, loosening or nonunion. The average followup period was 7.8 years (range 5-10 years. We observed an average postoperative increase in the Knee Society Score from 40 to 90 points. There was improvement in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC scores in terms of pain, stiffness and physical function during activities of daily living. Conclusion: Bone grafting for defects in primary total knee is justified as it is biological, available then and is cost effective besides preserving bone stock for future revisions. Structural grafts should be used in defects >5 mm deep and involving 25-40% of the cut proximal tibial condyle surface. For larger peripheral vertical defects, impaction bone grafting contained in a mesh should be done.

  11. Oxidized zirconium versus cobalt-chromium against the native patella in total knee arthroplasty: Patellofemoral outcomes.

    Science.gov (United States)

    Matassi, Fabrizio; Paoli, Tommaso; Civinini, Roberto; Carulli, Christian; Innocenti, Massimo

    2017-10-01

    Oxidized zirconium (OxZr) has demonstrated excellent mechanical properties in vitro when used against articular cartilage; less coefficient of friction and less chondral damage have been found when compared with cobalt-chromium (CoCr) implants. However, controversy exists as to whether implants with a zirconium femoral component articulate safely with a native patella in total knee arthroplasty (TKA). To answer this question, the clinical and radiographic results were analysed from a group of patients who underwent a TKA with patella retention; the OxZr versus CoCr femoral components were compared. The present study prospectively evaluated 83 knees of 74 patients from 2009 to 2010. Each patient was evaluated clinically (visual analogue scale, Knee Society score, patellar score) and radiographically (long leg standing radiograph, anterior-posterior and latero-lateral projections, axial view of the patella) pre-operatively and postoperatively with a mean follow-up of 4.47years. The patellar tilt and shift, and progression of patellofemoral osteoarthritis were calculated with the axial view. There were no patient reported adverse reactions and none of the evaluated prostheses failed. Both the clinical and radiographic evaluations showed no statistically significant between-group differences. No adverse events were observed clinically or radiologically. These results justify pursuing the use of oxidized zirconium as an alternative bearing surface for a femoral component associated with patellar retention in TKA. Published by Elsevier B.V.

  12. Does post-operative knee awareness differ between knees in bilateral simultaneous total knee arthroplasty? Predictors of high or low knee awareness

    DEFF Research Database (Denmark)

    Nielsen, Katrine Abildgaard; Thomsen, Morten Grove; Latifi, Roshan

    2016-01-01

    PURPOSE: To evaluate the difference in post-operative knee awareness between knees in patients undergoing bilateral simultaneous total knee arthroplasty (TKA) and to assess factors predicting high or low knee awareness. METHODS: This study was conducted on 99 bilateral simultaneous TKAs performed...... at our institution from 2008 to 2012. All patients received one set of questionnaires [Forgotten Joint Score (FJS) and Oxford Knee Score (OKS)] for each knee. Based on the FJS, the patients' knees were divided into two groups: "best" and "worst" knees. The median of the absolute difference in FJS and OKS...... within each patient was calculated. Multivariate linear regression was performed to identify factors affecting FJS. RESULTS: The difference between knees was 1 point (CI 0-5) for the FJS and 1 point (CI 0-2) for the OKS. The FJS for females increased (decreasing awareness) with increasing age. Males had...

  13. Using Patient Demographics and Statistical Modeling to Predict Knee Tibia Component Sizing in Total Knee Arthroplasty.

    Science.gov (United States)

    Ren, Anna N; Neher, Robert E; Bell, Tyler; Grimm, James

    2018-06-01

    Preoperative planning is important to achieve successful implantation in primary total knee arthroplasty (TKA). However, traditional TKA templating techniques are not accurate enough to predict the component size to a very close range. With the goal of developing a general predictive statistical model using patient demographic information, ordinal logistic regression was applied to build a proportional odds model to predict the tibia component size. The study retrospectively collected the data of 1992 primary Persona Knee System TKA procedures. Of them, 199 procedures were randomly selected as testing data and the rest of the data were randomly partitioned between model training data and model evaluation data with a ratio of 7:3. Different models were trained and evaluated on the training and validation data sets after data exploration. The final model had patient gender, age, weight, and height as independent variables and predicted the tibia size within 1 size difference 96% of the time on the validation data, 94% of the time on the testing data, and 92% on a prospective cadaver data set. The study results indicated the statistical model built by ordinal logistic regression can increase the accuracy of tibia sizing information for Persona Knee preoperative templating. This research shows statistical modeling may be used with radiographs to dramatically enhance the templating accuracy, efficiency, and quality. In general, this methodology can be applied to other TKA products when the data are applicable. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

    Science.gov (United States)

    Schotanus, M G M; Pilot, P; Kaptein, B L; Draijer, W F; Tilman, P B J; Vos, R; Kort, N P

    2017-09-01

    A concern that arises with any new prosthesis is whether it will achieve satisfactory long-term implant stability. The gold standard of assessing the quality of fixation in a new or relatively new implant is to undertake a randomized controlled trial using radiostereometric analysis. It was hypothesized that both mobile-bearing total knee arthroplasty and fixed-bearing total knee arthroplasty have comparable migration patterns at 2-year follow-up. This study investigated two types of cemented total knee arthroplasty, the mobile- or fixed-bearing variant from the same family with use of radiostereometric analysis. This prospective, patient-blinded, randomized, controlled trial was designed to investigate early migration of the tibia component after two years of follow-up with use of radiostereometric analysis. A total of 50 patients were randomized to receive a mobile- or fixed-bearing TKA from the same family. Patients were evaluated during 2-year follow-up, including radiostereometric analysis, physical and clinical examination and patient reported outcome measures (PROMs). At two-year follow-up, the mean (±SD) maximum total point motion (MTPM) in the fixed-bearing group was 0.82 (±1.16) versus 0.92 mm (±0.64) in the mobile-bearing group (p = n.s) with the largest migration seen during the first 6 weeks (0.45 ± 0.32 vs. 0.54 ± 0.30). The clinical outcome and PROMs significantly improved within each group, not between both groups. Measuring early micromotion is useful for predicting clinical loosening that can lead to revision. The results of this study demonstrate that early migration of the mobile-bearing is similar to that of the fixed-bearing component at two years and was mainly seen in the first weeks after implantation. Randomized, single-blind, controlled trial, Level I.

  15. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    OpenAIRE

    Reinders, Jörn; Sonntag, Robert; Kretzer, Jan Philippe

    2014-01-01

    Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anteri...

  16. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    Science.gov (United States)

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  17. Development and validation of a weight-bearing finite element model for total knee replacement.

    Science.gov (United States)

    Woiczinski, M; Steinbrück, A; Weber, P; Müller, P E; Jansson, V; Schröder, Ch

    2016-01-01

    Total knee arthroplasty (TKA) is a successful procedure for osteoarthritis. However, some patients (19%) do have pain after surgery. A finite element model was developed based on boundary conditions of a knee rig. A 3D-model of an anatomical full leg was generated from magnetic resonance image data and a total knee prosthesis was implanted without patella resurfacing. In the finite element model, a restarting procedure was programmed in order to hold the ground reaction force constant with an adapted quadriceps muscle force during a squat from 20° to 105° of flexion. Knee rig experimental data were used to validate the numerical model in the patellofemoral and femorotibial joint. Furthermore, sensitivity analyses of Young's modulus of the patella cartilage, posterior cruciate ligament (PCL) stiffness, and patella tendon origin were performed. Pearson's correlations for retropatellar contact area, pressure, patella flexion, and femorotibial ap-movement were near to 1. Lowest root mean square error for retropatellar pressure, patella flexion, and femorotibial ap-movement were found for the baseline model setup with Young's modulus of 5 MPa for patella cartilage, a downscaled PCL stiffness of 25% compared to the literature given value and an anatomical origin of the patella tendon. The results of the conducted finite element model are comparable with the experimental results. Therefore, the finite element model developed in this study can be used for further clinical investigations and will help to better understand the clinical aspects after TKA with an unresurfaced patella.

  18. Difference between right and left side in total knee and unicondylar knee replacement: An interesting observation

    Directory of Open Access Journals (Sweden)

    Vasudevan Thirumal Selvan

    2005-02-01

    Full Text Available We report an observation made about the differences between right and left side in case of total knee and unicondylar knee replacement. It was found that unicondylar knee replacement was performed more commonly on the left side (66%, as compared to only 34% on right side, where as total knee replacement was more common on the right side (64% as compared to 36% on left side. The exact clinical utility of this difference is yet to be known.

  19. Prevalence of Total Hip and Knee Replacement in the United States.

    Science.gov (United States)

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  20. The Cost of Joint Replacement: Comparing Two Approaches to Evaluating Costs of Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L

    2018-02-21

    In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize

  1. Total knee arthroplasty in ochronosis

    Directory of Open Access Journals (Sweden)

    Vaibhav G. Patel, MBBS

    2015-09-01

    Full Text Available Alkaptonuria is disorder of tyrosine metabolism due to deficiency of homogentisic oxidase characterized by excretion of homogentisic acid in urine, deposition of oxidized homogensitate pigments in connective tissues and articular cartilages (ochronosis. The result is dark pigmentation and weakening of the tissues resulting in chronic inflammation and osteoarthritis. Management of alkaptonuric ochronic osteoarthritis is usually symptomatic and replacements have comparable outcomes to osteoarthritis in patients without ochronosis. I report a case of a patient with ochronosis of knee treated with total knee replacement and report operative pearls for surgery in this rare disorder.

  2. Long-term clinical outcomes and survivorship of press-fit condylar sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kulkarni, Sourabh S; Kim, Yoon-Hong

    2014-10-01

    We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and

  3. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    Science.gov (United States)

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  4. Improvements in knee biomechanics during walking are associated with increased physical activity after total knee arthroplasty.

    Science.gov (United States)

    Arnold, John B; Mackintosh, Shylie; Olds, Timothy S; Jones, Sara; Thewlis, Dominic

    2015-12-01

    Total knee arthroplasty (TKA) in people with knee osteoarthritis increases knee-specific and general physical function, but it has not been established if there is a relationship between changes in these elements of functional ability. This study investigated changes and relationships between knee biomechanics during walking, physical activity, and use of time after TKA. Fifteen people awaiting TKA underwent 3D gait analysis before and six months after surgery. Physical activity and use of time were determined in free-living conditions from a high resolution 24-h activity recall. After surgery, participants displayed significant improvements in sagittal plane knee biomechanics and improved their physical activity profiles, standing for 105 more minutes (p=0.001) and performing 64 min more inside chores on average per day (p=0.008). Changes in sagittal plane knee range of motion (ROM) and peak knee flexion positively correlated with changes in total daily energy expenditure, time spent undertaking moderate to vigorous physical activity, inside chores and passive transport (r=0.52-0.66, p=0.005-0.047). Restoration of knee function occurs in parallel and is associated with improvements in physical activity and use of time after TKA. Increased functional knee ROM is required to support improvements in total and context specific physical activity. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  5. Ten Year Follow-Up of Gap Balanced, Rotating Platform Total Knee Arthroplasty in Patients Under 60 Years of Age.

    Science.gov (United States)

    Lee, Jason H; Barnett, Steven L; Patel, Jay J; Nassif, Nader A; Cummings, Dennis J; Gorab, Robert S

    2016-01-01

    68 patients (91 primary total knee arthroplasties) were evaluated at a mean 10-year, minimum 5 year follow up in patients younger than sixty years of age utilizing the gap balanced, rotating platform design. Follow up assessment included implant survivorship, adverse events, x-rays, Knee Society rating system and clinical evaluation. Three revisions were performed with only one for aseptic loosening at 45 months. Two manipulations were performed in the early postoperative period. Survivorship of the rotating platform, gap balanced knee was 96.7% using surgical revision for any reason and 98.9% using aseptic loosening as endpoints. The rotating platform design using the gap balancing technique in young patients had excellent survivorship at 10-year mean follow up. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. International survey of primary and revision total knee replacement

    NARCIS (Netherlands)

    Kurtz, Steven M.; Ong, Kevin L.; Lau, Edmund; Widmer, Marcel; Maravic, Milka; Gomez-Barrena, Enrique; de Pina, Maria de Fatima; Manno, Valerio; Torre, Marina; Walter, William L.; de Steiger, Richard; Geesink, Rudolph G. T.; Peltola, Mikko; Roeder, Christoph

    2011-01-01

    Total knee arthroplasty (TKA) is currently the international standard of care for treating degenerative and rheumatologic knee joint disease, as well as certain knee joint fractures. We sought to answer the following three research questions: (1) What is the international variance in primary and

  7. The cyclops lesion after bicruciate-retaining total knee replacement

    Directory of Open Access Journals (Sweden)

    Mark A. Klaassen, MD, FACS

    2017-12-01

    Full Text Available The cyclops lesion is a localized anterior arthrofibrosis most commonly seen following anterior cruciate ligament reconstruction. The lesion forms at the anterior cruciate ligament insertion creating a painful extension block between femoral intercondylar notch and tibial plateau. We present 2 cases (3 knees in which cyclops lesions appeared atypically following bicruciate-retaining total knee replacement. Two lesions occurred in a single patient following bilateral knee replacement. One lesion occurred in an active sportswoman. All 3 resolved following arthroscopic debridement. We describe the presentation of this unusual complication and suggest keys to its diagnosis, treatment, and prevention. Keywords: Cyclops lesion, Bicruciate-retaining, Total knee arthroplasty, Extension deficit

  8. The Optimal Analgesic Block for Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Bendtsen, Thomas Fichtner; Moriggl, Bernhard; Chan, Vincent W

    2016-01-01

    Peripheral nerve block for total knee arthroplasty is ideally motor sparing while providing effective postoperative analgesia. To achieve these goals, one must understand surgical dissection techniques, distribution of nociceptive generators, sensory innervation of the knee, and nerve topography...

  9. Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

    Directory of Open Access Journals (Sweden)

    Karade Vikas

    2012-10-01

    Full Text Available Abstract Background In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. Methods A comparative study of the accuracy of extramedullary and intramedullary tibial cutting guides was carried out in 92 megaprosthetic knee replacements for distal femoral tumors. For the proximal tibia cut for tibial component placement, an extramedullary guide was used in 65 patients and an intramedullary guide was used in 27 patients. Tibial component alignment angles were measured in postoperative X-rays with the help of CAD software. Results There was more varus placement in coronal plane with extramedullary cutting guide (−1.18 +/− 2.4 degrees than the intramedullary guide (−0.34 +/− 2.31 degrees but this did not reach statistical significance. The goal of 90 +/− 2 degrees alignment of tibial component was achieved in 54% of patients in the extramedullary group versus 67% in the intramedullary group. In terms of sagittal plane alignment, extramedullary guide showed less accurate results (2.09 +/− 2.4 degrees than intramedullary guide (0.50 +/− 3.80 degrees for tibial component alignment, though 78% of patients were aligned within the goal of 0–5 degrees of tibial slope angle in extramedullary group versus 63% in intramedullary group. The mean error in the measurements due to rotation of the knee during taking the X-rays was less than 0.1 degrees and distribution of the X-rays with the rotation of knee was similar in both the groups. Conclusions Overall, in megaprosthetic knee replacement intramedullary guides gave more accurate results in sagittal plane and exhibited similar variability as of extramedullary guides in coronal plane.

  10. 3D reconstruction of bony elements of the knee joint and finite element analysis of total knee prosthesis obtained from the reconstructed model.

    Science.gov (United States)

    Djoudi, Farid

    2013-01-01

    Two separate themes are presented in this paper. The first theme is to present a graphical modeling approach of human anatomical structures namely, the femur and the tibia. The second theme involves making a finite element analysis of stresses, displacements and deformations in prosthetic implants (the femoral implant and the polyethylene insert). The graphical modeling approach comes in two parts. The first is the segmentation of MRI scanned images, retrieved in DICOM format for edge detection. In the second part, 3D-CAD models are generated from the results of the segmentation stage. The finite element analysis is done by first extracting the prosthetic implants from the reconstructed 3D-CAD model, then do a finite element analysis of these implants under objectively determined conditions such as; forces, allowed displacements, the materials composing implant, and the coefficient of friction. The objective of this work is to implement an interface for exchanging data between 2D MRI images obtained from a medical diagnosis of a patient and the 3D-CAD model used in various applications, such as; the extraction of the implants, stress analysis at the knee joint and can serve as an aid to surgery, also predict the behavior of the prosthetic implants vis-a-vis the forces acting on the knee joints.

  11. Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.

    Science.gov (United States)

    de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico

    2017-11-01

    Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  12. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    OpenAIRE

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance ima...

  13. Total knee replacement and non-surgical treatment of knee osteoarthritis

    DEFF Research Database (Denmark)

    Skou, Søren T; Roos, Ewa M; Laursen, Mogens B

    2018-01-01

    OBJECTIVES: To compare 2-year outcomes of total knee replacement (TKR) followed by non-surgical treatment to that of non-surgical treatment alone and outcomes of the same non-surgical treatment to that of written advice. DESIGN: In two randomized trials, 200 (mean age 66) adults with moderate...... to severe knee osteoarthritis (OA), 100 eligible for TKR and 100 not eligible for TKR, were randomized to TKR followed by non-surgical treatment, non-surgical treatment alone, or written advice. Non-surgical treatment consisted of 12 weeks of supervised exercise, education, dietary advice, use of insoles......, and pain medication. The primary outcome was the mean score of the Knee Injury and Osteoarthritis Outcome Score (KOOS) subscales, covering pain, symptoms, activities of daily living (ADL), and quality of life (QOL). RESULTS: Patients randomized to TKR had greater improvements than patients randomized...

  14. In vitro method for assessing the biomechanics of the patellofemoral joint following total knee arthroplasty.

    Science.gov (United States)

    Coles, L G; Gheduzzi, S; Miles, A W

    2014-12-01

    The patellofemoral joint is a common site of pain and failure following total knee arthroplasty. A contributory factor may be adverse patellofemoral biomechanics. Cadaveric investigations are commonly used to assess the biomechanics of the joint, but are associated with high inter-specimen variability and often cannot be carried out at physiological levels of loading. This study aimed to evaluate the suitability of a novel knee simulator for investigating patellofemoral joint biomechanics. This simulator specifically facilitated the extended assessment of patellofemoral joint biomechanics under physiological levels of loading. The simulator allowed the knee to move in 6 degrees of freedom under quadriceps actuation and included a simulation of the action of the hamstrings. Prostheses were implanted on synthetic bones and key soft tissues were modelled with a synthetic analogue. In order to evaluate the physiological relevance and repeatability of the simulator, measurements were made of the quadriceps force and the force, contact area and pressure within the patellofemoral joint using load cells, pressure-sensitive film, and a flexible pressure sensor. The results were in agreement with those previously reported in the literature, confirming that the simulator is able to provide a realistic physiological loading situation. Under physiological loading, average standard deviations of force and area measurements were substantially lower and comparable to those reported in previous cadaveric studies, respectively. The simulator replicates the physiological environment and has been demonstrated to allow the initial investigation of factors affecting patellofemoral biomechanics following total knee arthroplasty. © IMechE 2014.

  15. The prosthetic implant of MBA Optetrak in the treatment of knee osteoarthritis: 5 years of experience.

    Science.gov (United States)

    Pedrazzini, A; Pogliacomi, F; Scaravella, E; Pompili, M; Ceccarelli, F

    2014-09-24

    In this study the authors report their experience in treating knee osteoarthritis with MBA Optetrak prosthetic implant, designed to minimize the stress of high density polyethylene. In all patients, we implanted two different Optetrak prosthesis according to the validity or not of the posterior cruciate ligament. At follow-up visit, which was performed after an average follow-up of 3.6 years, we analyzed 53 patients radiographically and clinically using the Knee Society Score (KSS). Depending on our experience, we consider mandatory to have a precise selection of the patients as well as to perform an accurate capsular and ligamentous balance during operation. Furthermore, the use of prosthesis models which are similar to the normal knee allows to obtain good and durable results.

  16. Extensor Mechanism Disruption after Total Knee Arthroplasty: A Case Series and Review of Literature.

    Science.gov (United States)

    Vaishya, Raju; Agarwal, Amit Kumar; Vijay, Vipul

    2016-02-04

    Extensor mechanism disruption following total knee arthroplasty (TKA) is a rare but devastating complication. These patients may require revision of the implants, but even then, it may not be possible to restore the normal function of the knee after the disruption. The patterns of extensor mechanism disruption can broadly be classified into three types: suprapatellar (quadriceps tendon rupture), transpatellar (patellar fracture), or infrapatellar (patellar tendon rupture). Infrapatellar tendon ruptures are the worst injuries, as they carry maximum morbidity and are challenging to manage. The disruption of the extensor mechanism may occur either intra-operatively or in the immediate postoperative period due to an injury. The treatment of extensor mechanism complications after TKA may include either nonsurgical management or surgical intervention in the form of primary repair or reconstruction with autogenous, allogeneic, or synthetic substitutes. We have provided an algorithm for the management of extensor mechanism disruption after TKA.

  17. The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology: Review Article.

    Science.gov (United States)

    Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio; Lepri, Andrea Cozzi; Sirleo, Luigi; Innocenti, Massimo

    2017-02-01

    Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. We performed a review of national joint registries trying to answer the following questions: "Which is the main factor directly related to revisions rate in TKA?" and "Are there new bearing options better than conventional ones?" A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.

  18. Customized versus Patient-Sized Cruciate-Retaining Total Knee Arthroplasty: An In Vivo Kinematics Study Using Mobile Fluoroscopy.

    Science.gov (United States)

    Zeller, Ian M; Sharma, Adrija; Kurtz, William B; Anderle, Mathew R; Komistek, Richard D

    2017-04-01

    Historically, knee arthroplasties have been designed using average patient anatomy. Recent advances in imaging and manufacturing have facilitated the development of customized prostheses designed to fit the unique shape of individual patients. The purpose of this study is to determine if improving implant design through customized total knee arthroplasty (TKA) improves kinematic function. Using state-of-the-art mobile fluoroscopy, tibiofemoral kinematics were analyzed for 24 subjects with a customized individually made (CIM), cruciate-retaining TKA, and 14 subjects having an asymmetric condylar cruciate-retaining TKA. Subjects performed a weight-bearing deep knee bend and a rise from a seated position. Each patient was evaluated for weight-bearing range of motion, femorotibial translation, femorotibial axial rotation, and condylar liftoff occurrence. Subjects having a CIM TKA experienced greater weight-bearing knee flexion compared with the traditional posterior cruciate-retaining (PCR) TKA design. During flexion, the CIM TKA subjects consistently exhibited more posterior femoral rollback than the traditional PCR TKA subjects. The CIM TKA was found to have statistically greater axial rotation compared with the traditional PCR TKA (P = .05). Of note, only the CIM TKA patients experienced femoral internal rotation at full extension, as exhibited in a normal knee. Compared with the traditional PCR TKA, the CIM TKAs demonstrated minimal occurrences of paradoxical sliding and reverse rotation during flexion and extension. The CIM TKA subjects showed minimal liftoff and hence better stability in earlyflexion to midflexion compared with the traditional PCR subjects. The CIM TKA demonstrated kinematics more similar to a normal knee. Therefore, using customized implant technology through CIM TKA designs affords benefits including more normal motion compared with a traditional PCR TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Revision of unicompartmental knee arthroplasty: implants used and causes of failure

    Directory of Open Access Journals (Sweden)

    Alan de Paula Mozella

    2014-04-01

    Full Text Available OBJECTIVE: to determine the causes of unicondylar knee arthroplasty failures, as well as identify the implants used and the need of bone grafting in patients undergoing revision UKA in Center of Knee Surgery at the Instituto Nacional de Traumatologia e Ortopedia (INTO in the period between January 1990 and January 2013.METHODS: a retrospective analysis of the medical documentation and imaging, determining the cause of failure of UKA and the time of its occurrence, as well as prosthetic components implanted during the review and the need for bone grafting.RESULTS: in this study, 27 UKA failures in 26 patients were included. Collapse of one or more components was the main cause of failure, occurring in 33% of patients. Aseptic failure was identified in 30% of cases, progression of osteoarthrosis in 15%, infection and pain 7% each, and osteolysis and polyethylene failure in 4% each. Early failure occurred in 41% of all revisions of UKA and late failure in 59%. 23 patients have undergone revision of UK.CONCLUSION: in 35% of revisions the use of bone grafting was needed in tibial area; in 3 cases we needed allograft from Tissue Bank. We did not use metal increase in any of the revision. In one patient we used implant constraint for instability.

  20. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Siddiq, M.Z.; Qayum, H.

    2006-01-01

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  1. Thigh and knee circumference, knee-extension strength, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Husted, Henrik

    2011-01-01

    OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective, descrip......OBJECTIVE: To (1) quantify changes in knee-extension strength and functional-performance at discharge after fast-track total hip arthroplasty (THA) and (2) investigate whether these changes correlate to changes in thigh and knee circumference (ie, swelling) or pain. DESIGN: A prospective......, descriptive, hypothesis-generating study. SETTING: A special unit for fast-track hip and knee arthroplasty operations at a university hospital. PARTICIPANTS: Twenty-four patients (20 women and 4 men; ages 69 ± 6.1 years) scheduled for primary unilateral THA. METHODS: All patients were evaluated before surgery......, except for hip pain. The average loss in knee-extension strength after surgery (32%, P = .01) did not correlate with increased thigh circumference (6%, P

  2. Knee awareness and functionality after simultaneous bilateral vs unilateral total knee arthroplasty

    DEFF Research Database (Denmark)

    Latifi, Roshan; Thomsen, Morten Grove; Kallemose, Thomas

    2016-01-01

    AIM: To investigate knee awareness and functional outcomes in patients treated with simultaneous bilateral vs unilateral total knee arthroplasty (TKA). METHODS: Through a database search, we identified 210 patients who had undergone unilateral TKA (UTKA) and 65 patients who had undergone......-surgical treatments were failed, thus preoperatively the patients had poor functionality. All patients were asked to complete Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) questionnaires. The patients were matched according to age, gender, year of surgery, Kellgren-Lawrence score and pre- and postoperative...... overall knee alignment. The FJS and OKS questionnaire results of the two groups were then compared. RESULTS: A mixed-effects model was used to analyze differences between SBTKA and UTKA. OKS: The mean difference in the OKS between the patients who had undergone SBTKA and those who had undergone UTKA was 1...

  3. Evaluation of interference fit and bone damage of an uncemented femoral knee implant.

    Science.gov (United States)

    Berahmani, Sanaz; Hendriks, Maartje; de Jong, Joost J A; van den Bergh, Joop P W; Maal, Thomas; Janssen, Dennis; Verdonschot, Nico

    2018-01-01

    During implantation of an uncemented femoral knee implant, press-fit interference fit provides the primary stability. It is assumed that during implantation a combination of elastic and plastic deformation and abrasion of the bone will occur, but little is known about what happens at the bone-implant interface and how much press-fit interference fit is eventually achieved. Five cadaveric femora were prepared and implantation was performed by an experienced surgeon. Micro-CT- and conventional CT-scans were obtained pre- and post-implantation for geometrical measurements and to measure bone mineral density. Additionally, the position of the implant with respect to the bone was determined by optical scanning of the reconstructions. By measuring the differences in surface geometry, assessments were made of the cutting error, the actual interference fit, the amount of bone damage, and the effective interference fit. Our analysis showed an average cutting error of 0.67mm (SD 0.17mm), which pointed mostly towards bone under-resections. We found an average actual AP interference fit of 1.48mm (SD 0.27mm), which was close to the nominal value of 1.5mm. We observed combinations of bone damage and elastic deformation in all bone specimens, which showed a trend to be related with bone density. Higher bone density tended to lead to lower bone damage and higher elastic deformation. The results of the current study indicate different factors that interact while implanting an uncemented femoral knee component. This knowledge can be used to fine-tune design criteria of femoral components to achieve adequate primary stability for all patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Knee injury and obesity in patients undergoing total knee replacement: a retrospective study in 115 patients

    DEFF Research Database (Denmark)

    Jensen, Claus Hjorth; Rofail, S

    1999-01-01

    The prevalence of obesity and previous knee injury was assessed in a retrospective study of 115 patients under-going total knee replacement due to osteoarthritis. Obesity was considered a contributing factor in the development of osteoarthritis in 37% of the patients, and 33% of the patients had...... had an injury to the knee in question. Unilateral osteoarthritis was significantly more frequent than bilateral osteoarthritis among patients with a history of previous knee injury. The association of previous injury to the knee and unilateral osteoarthritis was stronger in men than women. Aggressive...... treatment of patients with knee injuries seems warranted....

  5. Efficacy of pre-operative quadriceps strength training on knee-extensor strength before and shortly following total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Rasmus Skov; Troelsen, Anders; Thorborg, Kristian

    2018-01-01

    BACKGROUND: Patients with knee osteoarthritis (OA) report knee pain, limitation in physical activities and low quality of life. The two primary treatments for knee OA are non-surgical treatment (e.g., exercise) and surgery (total knee arthroplasty (TKA)); however, national guidelines recommend non...

  6. Secondary knee instability caused by fracture of the stabilizing insert in a dual-articular total knee

    DEFF Research Database (Denmark)

    Boesen, Morten P; Jensen, Tim Toftgaard; Husted, Henrik

    2004-01-01

    A case of a fractured polyethylene stabilizing insert causing secondary knee instability in a Dual-articular total knee arthroplasty (TKA) is presented. A 65-year-old woman who underwent surgery with a Dual-articular TKA 4 years earlier had a well-functioning prosthesis until a fall, after which......-articular knee....

  7. Migração de parafuso em artroplastia total do joelho: relato clínico Screw migration in total knee arthroplasty: case report

    Directory of Open Access Journals (Sweden)

    Fernando Fonseca

    2010-01-01

    Full Text Available As complicações das artroplastias totais do joelho devidas ao material implantado são raras, exceto o desgaste do polietileno. O relato de migração de parafusos dentro da articulação do joelho é muito raro. Os autores relatam a migração intra-articular de um parafuso de segurança do polietileno numa artroplastia total do joelho com sacrifício do ligamento cruzado posterior (ATJ tipo Performance; Biomet, Warsaw, IN que obrigou a nova cirurgia para remoção do parafuso, substituição do componente de polietileno e aplicação de novo parafuso de fixação.Complications in total knee arthroplasty directly related to the implanted material are rare, with the exception of polyethylene wear. Descriptions of screw migration into the joint cavity are very rare. The authors report an intra-articular migration of a polyethylene safety screw in a total knee arthroplasty, with sacrifice of the posterior cruciate ligament (ATJ Performance type; Biomet, Warsaw, IN requiring a new surgery to remove the screw, replace the polyethylene insert and insert a new fixation screw.

  8. Total Knee Replacement in A Resource Constrained Environment: A ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... care patronage, and the recent trends of religious/faith healings. • Beliefs ... Prevalence and Pattern of Knee Osteoarthritis in a North Eastern. Nigerian Rural ... epidemiology of total knee replacement in South Korea: national.

  9. Radiographic and scintigraphic evaluation of total knee arthroplasty

    International Nuclear Information System (INIS)

    Schneider, R.; Soudry, M.

    1986-01-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent

  10. No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial.

    Science.gov (United States)

    Amaro, Joicemar Tarouco; Arliani, Gustavo Gonçalves; Astur, Diego Costa; Debieux, Pedro; Kaleka, Camila Cohen; Cohen, Moises

    2017-06-01

    Until now, there are no definitive conclusions regarding functional differences related to middle- and long-term everyday activities and patient pain following implantation of mobile- and fixed-platform tibial prostheses. The aim of this study was to determine whether there are middle-term differences in knee function and pain in patients undergoing fixed- and mobile-bearing total knee arthroplasty (TKA). Eligible patients were randomized into two groups: the first group received TKA implantation with a fixed tibial platform (group A); the second group received TKA with a mobile tibial platform (group B). Patients were followed up (2 years), and their symptoms and limitations in daily living activities were evaluated using the Knee Outcome Survey-Activities of Daily Living Scale (ADLS), in addition to pain evaluation assessed using the pain visual analogue scale (VAS). There were no significant differences in function and symptoms in the ADLS and VAS between the study groups. The type of platform used in TKA (fixed vs. mobile) does not change the symptoms, function or pain of patients 2 years post-surgery. Although mobile TKAs may have better short-term results, at medium- and long-term follow-up they do not present important clinical differences compared with fixed-platform TKAs. This information is important so that surgeons can choose the most suitable implant for each patient. Randomized clinical trial, Level I.

  11. Surgical Stabilization of the Medial Capsulo-Ligamentous Envelope in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Brandon Green, DO

    2014-10-01

    Full Text Available This study will evaluate an alternative method in which a four prong bone staple was used to repair the medial collateral ligament following over-release or avulsion injuries in (#6 cases during a total knee arthroplasty. The use of a four prong bone staple to repair medial collateral ligament injuries status post total knee replacement will provide satisfactory results with respect to post-operative knee stability and range of motion. Our retrospective review revealed that all six patients improved with regards to range of motion following the total knee arthroplasty. We feel that repair of the medial collateral ligament with a four-prong bone staple is a viable option after an over-release or avulsion injury sustained during a total knee arthroplasty.

  12. Myofascial Pain in Patients Waitlisted for Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Richard Henry

    2012-01-01

    Full Text Available BACKGROUND: Knee pain is one of the major sources of pain and disability in developed countries, particularly in aging populations, and is the primary indication for total knee arthroplasty (TKA in patients with osteoarthritis (OA.

  13. The effect of tourniquet use on fixation quality in cemented total knee arthroplasty a prospective randomized clinical controlled RSA trial.

    Science.gov (United States)

    Molt, Mats; Harsten, Andreas; Toksvig-Larsen, Sören

    2014-03-01

    A concern that arises with any change in technique is whether it affects the long-term implant stability. The objective of this study was to evaluate the early migration, measured by radiostereometric analysis (RSA), and the functional outcome of the Triathlon™ cemented knee prosthesis, operated on with or without a tourniquet. During the last decades RSA has emerged as a way to assess prosthetic fixation and long time prognosis. The method has been used extensively in both hip and knee arthroplasty. This was a single centre prospective study including 60 patients randomized into two groups operated on either with or without tourniquet. RSA investigation was done within 2-3 days postoperatively after full weight bearing, and then at 3 months, 1 year and 2 years postoperatively. There were no differences between the groups regarding the translation along or rotation around the three coordinal axes, or in maximum total point motion (MTPM). At 2 years the mean MTPM (SD) was 0.71 mm (0.64) for the tourniquet-group and 0.53 mm (0.21) for the non-tourniquet-group. The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability whether operated on with or without tourniquet. Level I. Article focus: A safety study for total knee replacement operated on with or without perioperative tourniquet regarding the prosthetic fixation. Strengths and limitations: Strength of this study is that it is a randomized prospective trial using an objective measuring tool. The sample size of 25-30 patients is reportedly sufficient for the screening of implants using RSA (1-3). Clinical trials NCT01604382, Ethics Committee approval D-nr: 144/20085. © 2013.

  14. The role of the posterior cruciate ligament in total knee replacement

    Science.gov (United States)

    Ritter, M. A.; Davis, K. E.; Meding, J. B.; Farris, A.

    2012-01-01

    Objectives The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement. Methods A total of 3018 anatomic graduated component total knee replacements were examined; 1846 of these retained the PCL, 455 PCLs were partially recessed, and in 717 the PCL was completely excised from the back of the tibia. Results Clinical scores between PCL groups favored excision for flexion (p knees, 98.2% for recessed knees, and 96.4% for excised knees (p = 0.0934, Wilcoxon; p = 0.0202, log-rank). Conclusions Despite some trade off in clinical performance, if the PCL is detached at the time of operation, conversion to a posterior-stabilised prosthesis may not be necessarily required as long as stability in the anteroposterior and coronal planes is achieved. PMID:23610673

  15. Dislocation following total knee arthroplasty: A report of six cases

    Directory of Open Access Journals (Sweden)

    Villanueva Manuel

    2010-01-01

    Full Text Available Background: Dislocation following total knee arthroplasty (TKA is the worst form of instability. The incidence is from 0.15 to 0.5%. We report six cases of TKA dislocation and analyze the patterns of dislocation and the factors related to each of them. Materials and Methods: Six patients with dislocation of knee following TKA are reported. The causes for the dislocations were an imbalance of the flexion gap (n=4, an inadequate selection of implants (n=1, malrotation of components (n=1 leading to incompetence of the extensor mechanism, or rupture of the medial collateral ligament (MCC. The patients presented complained of pain, giving way episodes, joint effusion and difficulty in climbing stairs. Five patients suffered posterior dislocation while one anterior dislocation. An urgent closed reduction of dislocation was performed under general anaesthesia in all patients. All patients were operated for residual instability by revision arthroplasty after a period of conservative treatment. Results: One patient had deep infection and knee was arthrodesed. Two patients have a minimal residual lag for active extension, including a patient with a previous patellectomy. Result was considered excellent or good in four cases and fair in one, without residual instability. Five out of six patients in our series had a cruciate retaining (CR TKA designs: four were revised to a posterior stabilized (PS TKA and one to a rotating hinge design because of the presence of a ruptured MCL. Conclusion: Further episodes of dislocation or instability will be prevented by identifying and treating major causes of instability. The increase in the level of constraint and correction of previous technical mistakes is mandatory.

  16. The cyclops lesion after bicruciate-retaining total knee replacement

    OpenAIRE

    Klaassen, Mark A.; Aikins, Jerry L.

    2017-01-01

    The cyclops lesion is a localized anterior arthrofibrosis most commonly seen following anterior cruciate ligament reconstruction. The lesion forms at the anterior cruciate ligament insertion creating a painful extension block between femoral intercondylar notch and tibial plateau. We present 2 cases (3 knees) in which cyclops lesions appeared atypically following bicruciate-retaining total knee replacement. Two lesions occurred in a single patient following bilateral knee replacement. One les...

  17. Pain and senzitisation after total knee replacement or nonsurgical treatment in patients with knee osteoarthritis

    DEFF Research Database (Denmark)

    Arendt-Nielsen, Lars; Simonsen, Ole; Laursen, Mogens Berg

    2018-01-01

    BACKGROUND: This study is a secondary analysis of 12-month follow-ups from two parallel, randomised controlled trials (RCT) in painful knee osteoarthritis patients. RCT1: Total knee replacement (TKR) followed by non-surgical treatment compared with non-surgical treatment. RCT2: Non...

  18. Knee implant imaging at 3 Tesla using high-bandwidth radiofrequency pulses.

    Science.gov (United States)

    Bachschmidt, Theresa J; Sutter, Reto; Jakob, Peter M; Pfirrmann, Christian W A; Nittka, Mathias

    2015-06-01

    To investigate the impact of high-bandwidth radiofrequency (RF) pulses used in turbo spin echo (TSE) sequences or combined with slice encoding for metal artifact correction (SEMAC) on artifact reduction at 3 Tesla in the knee in the presence of metal. Local transmit/receive coils feature increased maximum B1 amplitude, reduced SAR exposition and thus enable the application of high-bandwidth RF pulses. Susceptibility-induced through-plane distortion scales inversely with the RF bandwidth and the view angle, hence blurring, increases for higher RF bandwidths, when SEMAC is used. These effects were assessed for a phantom containing a total knee arthroplasty. TSE and SEMAC sequences with conventional and high RF bandwidths and different contrasts were tested on eight patients with different types of implants. To realize scan times of 7 to 9 min, SEMAC was always applied with eight slice-encoding steps and distortion was rated by two radiologists. A local transmit/receive knee coil enables the use of an RF bandwidth of 4 kHz compared with 850 Hz in conventional sequences. Phantom scans confirm the relation of RF bandwidth and through-plane distortion, which can be reduced up to 79%, and demonstrate the increased blurring for high-bandwidth RF pulses. In average, artifacts in this RF mode are rated hardly visible for patients with joint arthroplasties, when eight SEMAC slice-encoding steps are applied, and for patients with titanium fixtures, when TSE is used. The application of high-bandwidth RF pulses by local transmit coils substantially reduces through-plane distortion artifacts at 3 Tesla. © 2014 Wiley Periodicals, Inc.

  19. Normalized knee-extension strength or leg-press power after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Aalund, Peter K; Larsen, Kristian; Hansen, Torben Bæk

    2013-01-01

    OBJECTIVE: (s): To investigate which of the two muscle-impairment measures for the operated leg, normalized knee extension strength or leg press power, is more closely associated to performance-based and self-reported measures of function shortly following total knee arthroplasty (TKA). DESIGN...... and dynamic leg presses to determine their body-mass normalized knee extension strength and leg press power, respectively. The 10-m fast speed walking and 30-s chair stand tests were used to determine performance-based function, while the Western Ontario McMaster University Osteoarthritis Index (WOMAC......) and Oxford Knee scores were used to determine self-reported function. RESULTS: Normalized leg press power was more closely associated to both performance-based (r=.82, P...

  20. Characteristic complications after autologous chondrocyte implantation for cartilage defects of the knee joint

    DEFF Research Database (Denmark)

    Niemeyer, Philipp; Pestka, Jan M; Kreuz, Peter C

    2008-01-01

    BACKGROUND: Although autologous chondrocyte implantation (ACI) is a well-established therapy for the treatment of isolated cartilage defects of the knee joint, little is known about typical complications and their treatment after ACI. HYPOTHESIS: Unsatisfactory outcome after ACI is associated...

  1. Opinions among Danish knee surgeons about indications to perform total knee replacement showed considerable variation

    DEFF Research Database (Denmark)

    Troelsen, Anders; Schrøder, Henrik; Husted, Henrik

    2012-01-01

    During the past decade, the incidence of primary total knee replacement (TKA) surgery in Denmark has approximately doubled. This increase could be due to weakened indications to perform TKA surgery. We aimed to investigate variation in opinions about indications to perform TKA among Danish knee...

  2. Nurse-led telephone follow-up after total knee arthroplasty

    DEFF Research Database (Denmark)

    Szöts, Kirsten; Konradsen, Hanne; Solgaard, Søren

    2015-01-01

    AIM AND OBJECTIVES: To generate information on how telephone follow-up consultations, structured by nursing status according to the VIPS-model, functioned after total knee arthroplasty. The objectives were to unfold the content of the telephone follow-ups according to the structure for nursing...... status and to explore the patients' views of the telephone follow-ups. BACKGROUND: The length of stay in hospital following total knee arthroplasty has fallen markedly, and patients now have to be responsible for their recovery from a very early stage. After discharge, patients may experience a variety...... Telephone follow-up was valued by total knee arthroplasties patients as representing a holistic approach and providing adequate information, counselling and support after discharge to home. Three categories were identified with regard to the patients' views: 'A means for reflection and provision of adequate...

  3. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Science.gov (United States)

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement

  4. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Denkena Berend

    2010-06-01

    Full Text Available Abstract Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in

  5. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    Science.gov (United States)

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  6. Total hip and knee joint replacement: perioperative clinical aspects

    Directory of Open Access Journals (Sweden)

    Luciana Pereira Almeida de Piano

    2010-09-01

    Full Text Available Objective: To understand the profile of patients undergoing hip and knee replacement during two years, and to compare the data obtained with the literature. Methods: A total of 323 medical records were reviewed to analyze the perioperative data of patients submitted to hip and knee replacement. Results: Osteoarthritis was the main indication for both procedures and male patients were heavier than females (p < 0.05. Hypertension was the prevalent disease among patients. Blood loss was more frequent in knee surgery than in the hip. Conclusions: The profile of patients undergoing total arthroplasty improved substantially over the past decade due to shorter hospital stay, lower risk of thromboembolic events and no infection as compared to previous reports.

  7. Position controlled Knee Rehabilitation Orthotic Device for Patients after Total Knee Replacement Arthroplasty

    Science.gov (United States)

    Wannaphan, Patsiri; Chanthasopeephan, Teeranoot

    2016-11-01

    Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.

  8. Periprosthetic fracture-dislocation in a loosened total knee replacement treated by knee arthrodesis

    International Nuclear Information System (INIS)

    Lozano Moreno, Francisco Jose

    2004-01-01

    We present a patient who was operated four years before performing a total knee replacement. She fell down resulting a periprosthetic femoral fracture and a prosthetic dislocation. After evaluating different treatments, we decided to do prosthetic removal and a knee arthrodesis using an intramedullar nail. The femoral fracture was fixed with wire cerclages. Knee arthrodesis is a procedure uses as a last option for the treatment of infected or loosed arthroplasties. In our case it was difficult to consider any other reconstructive procedure due to the association of fracture, dislocation and loosening. The evolution has been satisfactory with good functional result and without pain

  9. Management of chronic lateral instability due to lateral collateral ligament deficiency after total knee arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Petersilge William J

    2010-05-01

    Full Text Available Abstract Introduction Lateral instability following total knee arthroplasty (TKA is a rare condition with limited report of treatment options. The objective of this case presentation is to demonstrate the outcomes of different surgical procedures performed in a single patient with lateral collateral ligament (LCL deficiency. Case presentation We present a case of chronic lateral instability due to LCL deficiency after primary TKA in a 47-year-old Caucasian woman with an obesity problem. Multiple treatment options have been performed in order to manage this problem, including the following: ligament reconstruction; combined ligament reconstruction and constrained implant; and rotating-hinge knee prosthesis that was the most recent surgery. All ligament reconstruction procedures failed within one year. The varus-valgus constrained prosthesis provided stability for six years. Conclusions Ligament reconstruction alone cannot provide enough stability for the treatment of chronic lateral instability in patients with obesity problems and LCL deficiency. When the reconstruction fails, a salvage procedure with rotating-hinge knee is still available.

  10. Knee injury and Osteoarthritis Outcome Score (KOOS – validation and comparison to the WOMAC in total knee replacement

    Directory of Open Access Journals (Sweden)

    Roos Ewa M

    2003-05-01

    Full Text Available Abstract Background The Knee injury and Osteoarthritis Outcome Score (KOOS is an extension of the Western Ontario and McMaster Universities Osteoarthrtis Index (WOMAC, the most commonly used outcome instrument for assessment of patient-relevant treatment effects in osteoarthritis. KOOS was developed for younger and/or more active patients with knee injury and knee osteoarthritis and has in previous studies on these groups been the more responsive instrument compared to the WOMAC. Some patients eligible for total knee replacement have expectations of more demanding physical functions than required for daily living. This encouraged us to study the use of the Knee injury and Osteoarthritis Outcome Score (KOOS to assess the outcome of total knee replacement. Methods We studied the test-retest reliability, validity and responsiveness of the Swedish version LK 1.0 of the KOOS when used to prospectively evaluate the outcome of 105 patients (mean age 71.3, 66 women after total knee replacement. The follow-up rates at 6 and 12 months were 92% and 86%, respectively. Results The intraclass correlation coefficients were over 0.75 for all subscales indicating sufficient test-retest reliability. Bland-Altman plots confirmed this finding. Over 90% of the patients regarded improvement in the subscales Pain, Symptoms, Activities of Daily Living, and knee-related Quality of Life to be extremely or very important when deciding to have their knee operated on indicating good content validity. The correlations found in comparison to the SF-36 indicated the KOOS measured expected constructs. The most responsive subscale was knee-related Quality of Life. The effect sizes of the five KOOS subscales at 12 months ranged from 1.08 to 3.54 and for the WOMAC from 1.65 to 2.56. Conclusion The Knee injury and Osteoarthritis Outcome Score (KOOS is a valid, reliable, and responsive outcome measure in total joint replacement. In comparison to the WOMAC, the KOOS improved validity

  11. Coupling failure between stem and femoral component in a constrained revision total knee arthroplasty.

    LENUS (Irish Health Repository)

    Butt, Ahsan Javed

    2013-02-01

    Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use of a cemented femoral stem, screw fixation and the metaphyseal sleeve of an S-ROM modular hip system (DePuy international Ltd).

  12. Total Knee Replacement: 12 Years Retrospective Review and Experience

    Directory of Open Access Journals (Sweden)

    Ahmad Hafiz Z

    2011-03-01

    Full Text Available This retrospective study was undertaken to evaluate the outcome of primary total knee arthroplasty (TKA performed from January 1986 to December 1997 at this institution. Case review included Knee Society scores and functional knee score. The records of 94 patients (128 knees were available for analysis with the sample comprised of 76 females (80.9% and 18 males (19.1% and a mean age was 61.4 years. TKA was performed for osteoarthritis (OA in 96 knees (75% and rheumatoid arthritis (RA in 32 knees (25%. Cemented TKAs were performed in all patients. The mean knee score improved from 38.8 preoperatively to 90.9 postoperatively. The mean functional score improved from 19.1 preoperatively to 62.5 postoperatively. Both scores showed significant improvement when comparing preoperative to post operative results (p< 0.005. Arthroplasty was designated failures if the prostheses used had been removed. Survivorship at 12 years was 89.5%.

  13. Cartilage Health in Knees Treated with Metal Resurfacing Implants or Untreated Focal Cartilage Lesions: A Preclinical Study in Sheep.

    Science.gov (United States)

    Martinez-Carranza, Nicolas; Hultenby, Kjell; Lagerstedt, Anne Sofie; Schupbach, Peter; Berg, Hans E

    2017-07-01

    Background Full-depth cartilage lesions do not heal and the long-term clinical outcome is uncertain. In the symptomatic middle-aged (35-60 years) patient, treatment with metal implants has been proposed. However, the cartilage health surrounding these implants has not been thoroughly studied. Our objective was to evaluate the health of cartilage opposing and adjacent to metal resurfacing implants. Methods The medial femoral condyle was operated in 9 sheep bilaterally. A metallic resurfacing metallic implant was immediately inserted into an artificially created 7.5 mm defect while on the contralateral knee the defect was left untreated. Euthanasia was performed at 6 months. Six animals, of similar age and study duration, from a previous study were used for comparison in the evaluation of cartilage health adjacent to the implant. Cartilage damage to joint surfaces within the knee, cartilage repair of the defect, and cartilage adjacent to the implant was evaluated macroscopically and microscopically. Results Six animals available for evaluation of cartilage health within the knee showed a varying degree of cartilage damage with no statistical difference between defects treated with implants or left untreated ( P = 0.51; 95% CI -3.7 to 6.5). The cartilage adjacent to the implant (score 0-14; where 14 indicates no damage) remained healthy in these 6 animals showing promising results (averaged 10.5; range 9-11.5, SD 0.95). Cartilage defects did not heal in any case. Conclusion Treatment of a critical size focal lesion with a metal implant is a viable alternative treatment.

  14. Total Knee Replacement: a Preliminary Report Thirteen (13) Cases ...

    African Journals Online (AJOL)

    Background: Total Knee Arthroplasty (TKA) is a major technical procedure. Since its introduction it has become a successful procedure for treating various forms of pathologies in the knee associated with severe pain and disabling deformities such as severe osteoarthritis. Although various systems exist, they are broadly ...

  15. Mid-term results of total knee arthroplasty with a porous tantalum monoblock tibial component.

    Science.gov (United States)

    Hayakawa, Kazue; Date, Hideki; Tsujimura, Shunzo; Nojiri, Sho; Yamada, Harumoto; Nakagawa, Kenji

    2014-01-01

    The objectives of the present study were to assess the mid-term results of cementless total knee arthroplasty (TKA) with the porous tantalum monoblock tibial component and to examine the time course of bone changes on plain radiographs. The subjects were 32 patients, 29 patients were available for follow-up. We investigated the mid-term results of TKA after a mean follow-up period of 7 years and 8 months. We also examined changes of the bone over time on plain radiographs. The Knee Society Clinical Rating scores showed significant improvement. Bone changes around the tibial component were as follows: new bone formation and longitudinal trabecular thickening in 41.4% (Type A), only longitudinal trabecular thickening in 41.4% (Type B), and no changes in 17.2% (Type C). Type A and B changes were more frequent in patients with osteoarthritis, whereas Type C was only seen in patients with rheumatoid arthritis. Three knees had an initial gap, but this disappeared in all cases, and no new radiolucent lines were detected. Stress shielding was observed in seven knees (21.9%), but there was no implant loosening related to it. When we examined the relationship between the mechanical axis and the locations of the tips of the tibial pegs in patients with or without stress shielding, no significant differences were found. The results of mid-term follow-up have demonstrated favorable bone ingrowth, suggesting that porous tantalum is a promising material for cementless TKA. © 2013.

  16. Do we need a gender-specific total knee replacement?

    DEFF Research Database (Denmark)

    Thomsen, M G; Husted, H; Bencke, J

    2012-01-01

    The purpose of this study was to investigate whether a gender-specific high-flexion posterior-stabilised (PS) total knee replacement (TKR) would offer advantages over a high-flex PS TKR regarding range of movement (ROM), 'feel' of the knee, pain and satisfaction, as well as during activity. A total......, satisfaction and daily 'feel' of each knee. Patients underwent gait analysis pre-operatively and at one year, which yielded kinematic, kinetic and temporospatial parameters indicative of knee function during gait. At final follow-up we found no statistically significant differences in ROM (p = 0.......82). The median pain score was 0 (0 to 8) in both groups (p = 0.95). The median satisfaction score was 9 (4 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0.98). The median 'feel' score was 9 (3 to 10) in the high-flex group and 8 (0 to 10) in the gender-specific group (p = 0...

  17. Comparative analysis of quadriceps and hamstrings strength in knee osteoarthritis before and after total knee arthroplasty: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Naasson Trindade Cavanellas

    Full Text Available ABSTRACT Objective: Compare the maximal isokinetic muscle strength of knee extensor and flexor muscles between patients with knee osteoarthritis and patients submitted to total knee arthroplasty. Methods: Volunteers were divided into five groups (n = 20: Control; Ahlbäck I and II; Ahlbäck IV; six months after total knee arthroplasty; 12 months after total knee arthroplasty. An isokinetic knee strength evaluation was conducted for the quadriceps and hamstrings at 60°/s. Results: Significant differences in the peak torque of the quadriceps and hamstrings were found among the groups (p < 0.001. The Ahlbäck IV, six-month, and 12-month postoperative groups demonstrated lower values when compared to the Control and Ahlbäck I and II groups. When percentage values were compared to the Control group, mean differences ranged from 7% to 41%. Conclusion: Patients with healthy knees or early stage osteoarthritis have higher quadriceps and hamstrings strengths than those with a more advanced stage of the disease, even after knee replacement. These findings suggest that the traditional rehabilitation programs do not recover strength to levels observed in individuals without knee osteoarthritis.

  18. A longitudinal study of quality of life and functional status in total hip and total knee replacement patients.

    Science.gov (United States)

    Mandzuk, Lynda L; McMillan, Diana E; Bohm, Eric R

    2015-05-01

    Primary total hip and primary total knee surgeries are commonly performed to improve patients' quality of life and functional status. This longitudinal retrospective study (N = 851) examined self-reported quality of life and functional status over the preoperative and postoperative periods: 12 months prior to surgery, one month prior to surgery and 12 months following surgery. A linear mixed effects model was used to analyze the changes in quality of life and functional status over the sampling period. Patients in the convenience sample reported improvements in quality of life and functional status utilizing the SF-12 and Oxford Hip and Oxford Knee, although differences were noted by procedure and gender. Total hip patients tended to demonstrate greater improvement than total knee patients and males reported higher levels of physical and mental quality of life as well as functional status when compared to females. Of particular note was that mental health scores were consistently lower in both total hip and total knee replacement patients across the perioperative period and up to one year postoperative. This study identifies an opportunity for health care providers to proactively address the mental health of total hip and total knee replacement patients throughout their joint replacement trajectory. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Total knee reconstruction without posterior stabilization in rheumatoid arthritis patients

    Directory of Open Access Journals (Sweden)

    Radu Prejbeanu

    2010-12-01

    Full Text Available Objectives: to present the results with posterior cruciate ligament-retaining total knee arthroplasty in rheumatoid arthritis (RA patients. Background: Total knee replacement in RA patients has many particularities. One of them is the difficulty of obtaining a proper ligamentous balance.Methods: 24 RA patients were followed for a 5-year period after posterior cruciate ligament-retaining total knee arthroplasty. Clinical assessments analyzed general health status by using Hospital for Special Surgery Knee Evaluation Form (HSSKEF and mediolateral and anteroposterior ligament stability by using varus-valgus and posterior drawer tests. Radiological assessments evaluated axial alignment, size and position of components, radiolucent lines in anteroposterior and lateral standard views, integrity of the posterior cruciate ligament on lateral view X-ray at 45 degrees of flexion.Results: the mean HSSKEF score increased from 32 to 84 points at the end of follow-up. Preoperative mean range of motion was 60 degrees; postoperative mean range of motion was of 105 degrees, with significant statistical difference (p<0.05. The mean femoral component axial deviation was 6 degrees. The tibial component had a mean axial deviation of 1 degree of varus. There were no radioluscency lines of more than 1mm. 21 patients had excellent results. None of the knees was unstable. Conclusion: posterior cruciate ligament-retaining total knee arthroplasty can be used in RA patients without excessive valgus deformity (over 15 degrees, providing thus sufficient stabilization. The outcomes re similar to those patients who followed a posterior stabilized endoprosthesis.

  20. Intraoperative joint gaps and mediolateral balance affect postoperative knee kinematics in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Muneta, Takeshi; Sekiya, Ichiro; Banks, Scott A

    2015-12-01

    Adjusting joint gaps and establishing mediolateral (ML) soft tissue balance are considered essential interventions for better outcomes in total knee arthroplasty (TKA). However, the relationship between intraoperative laxity measurements and weightbearing knee kinematics has not been well explored. This study aimed to quantify the effect of intraoperative joint gaps and ML soft tissue balance on postoperative knee kinematics in posterior-stabilized (PS)-TKA. We investigated 44 knees in 34 patients who underwent primary PS-TKA by a single surgeon. The central joint gaps and ML tilting angles at 0°, 10°, 30°, 60°, 90°, 120° and 135° flexion were measured during surgery. At a minimum of two year follow-up, we analyzed in vivo kinematics of these knees and examined the influence of intraoperative measurements on postoperative kinematics. Gap difference of knee flexion at 135° minus 0° was correlated with the total posterior translation of lateral femoral condyle (r=0.336, p=0.042) and femoral external rotation (r=0.488, p=0.002) during squatting, anteroposterior position of lateral femoral condyle (r=-0.510, p=0.001) and maximum knee flexion (r=0.355, p=0.031) in kneeling. Similar correlations were observed between deep flexion gap differences with respect to the 90° reference and postoperative knee kinematics. Well-balanced knees showed less anterior translation of medial femoral condyle in mid- to deep flexion, consistent femoral external rotation, and the most neutral valgus/varus rotation compared with unbalanced knees. These findings indicate the importance of adequate intraoperative joint gaps in deep flexion and ML soft tissue balance throughout the range of motion. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Contact Mechanics and Failure Modes of Compliant Polymeric Bearing Materials for Knee Cartilage Replacement

    Science.gov (United States)

    Tohfafarosh, Mariya Shabbir

    Osteoarthritis (OA) is the most common cause of disability affecting millions of people worldwide. Total knee replacement is the current state-of-the-art treatment to alleviate pain and improve mobility among patients in the late stage of knee OA. The current gold standard materials for total knee arthroplasty are cobalt-chromium and ultra-high molecular weight polyethylene (UHMWPE). However, wear debris and implant loosening-related revision persists; consequently, total knee replacements are not universally recommended for all patient subgroups with OA. This work explores the potential of using compliant polymeric materials in knee cartilage replacement devices, which are closer in lubrication and mechanical properties of articular cartilage, to prevent excessive removal of underlying bone and prolong the need for a total knee replacement. Two materials investigated in this thesis are polycarbonate urethane, Bionate 80A, and a novel hydrogel, Cyborgel, both of which have shown promising wear and lubrication properties under physiological loads. Polycarbonate urethane has been previously tested for the effects of gamma sterilization and has shown no significant changes in its mechanical strength or chemical bonds. Since an important aspect of medical device development is the sterilization process, this thesis first evaluated the effect of 30-35 kGy electron beam and gamma radiation on the polymer swell ratio, and the mechanical, chemical and tribological behavior of the novel hydrogel. Three different formulations were mechanically tested, and biphasic material properties were identified using finite element analysis. Fourier transform infrared spectroscopy was used to investigate chemical changes, while the wear properties were tested for 2 million cycles in bovine serum. The results showed no significant difference (p > 0.05) in the swell ratio, mechanical and tribological properties of the electron beam and gamma sterilized hydrogel sample as compared to the

  2. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty.

    Science.gov (United States)

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-04-01

    Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods - RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results - Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49-1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75-1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation - Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design.

  3. Navigated versus conventional total knee arthroplasty: A prospective study at three years follow-up.

    Science.gov (United States)

    Martín-Hernández, C; Sanz-Sainz, M; Revenga-Giertych, C; Hernández-Vaquero, D; Fernández-Carreira, J M; Albareda-Albareda, J; Castillo-Palacios, A; Ranera-Garcia, M

    2018-03-28

    Computer-assisted surgery application in total knee arthroplasty (TKA) has shown more accurate implant alignment compared with conventional instrumentation and is associated with more homogeneous alignment results. Although longer implant survival and superior clinical outcomes should be expected from navigated TKA, currently available evidence does not support this hypothesis. The aim of this study was to compare navigated TKA with conventional TKA regarding clinical and radiological outcomes after a 3-year follow-up under the hypothesis that navigated TKA would provide better outcomes than conventional TKA. In a prospective multicentre study, 119 patients underwent navigated TKA and 80 patients received conventional instrumentation. Patients were evaluated at the baseline and at postoperative months 3, 12, 24, and 36. Analysis included the American Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short Form-12 (SF12) Health Survey, and radiographic assessment. All clinical scores improved significantly for all patients during the follow-up but were significantly better in the navigation group. The percentage of patients showing a mechanical axis between 3° of varus and 3° of valgus was significantly higher in the ATR group (93%) than in the conventional TKA group (71%) (P<.01). The use of computer-assisted surgery in TKA provides more accurate mechanical alignment and superior short-term functional outcomes compared to conventional TKA. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Revision total knee arthroplasty with the use of trabecular metal cones

    DEFF Research Database (Denmark)

    Jensen, Claus L; Petersen, Michael Mygind; Schrøder, Henrik

    2012-01-01

    "Trabecular Metal Cone" (TM Cone) (Zimmer, Inc, Warsaw, Ind) for reconstruction of bone loss in the proximal tibia during revision total knee arthroplasty is now optional. Forty patients were randomized to receive revision total knee arthroplasty with or without TM Cone (No TM Cone). The Anderson...

  5. MR imaging of autologous chondrocyte implantation of the knee

    Energy Technology Data Exchange (ETDEWEB)

    James, S.L.J.; Connell, D.A.; Saifuddin, A.; Skinner, J.A.; Briggs, T.W.R. [RNOH Stanmore, Department of Radiology, Stanmore, Middlesex (United Kingdom)

    2006-05-15

    Autologous chondrocyte implantation (ACI) is a surgical technique that is increasingly being used in the treatment of full-thickness defects of articular cartilage in the knee. It involves the arthroscopic harvesting and in vitro culture of chondrocytes that are subsequently implanted into a previously identified chondral defect. The aim is to produce a repair tissue that closely resembles hyaline articular cartilage that gradually becomes incorporated, restoring joint congruity. Over the long term, it is hoped that this will prevent the progression of full-thickness articular cartilage defects to osteoarthritis. This article reviews the indications and operative procedure performed in ACI. Magnetic resonance imaging (MRI) sequences that provide optimal visualization of articular cartilage in the post-operative period are discussed. Normal appearances of ACI on MRI are presented along with common complications that are encountered with this technique. (orig.)

  6. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    Science.gov (United States)

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and

  7. Relationship between product demand, tibial polyethylene insert shelf age, and total knee arthroplasty survival: retrospective review of total knees of one design.

    Science.gov (United States)

    Urban, Joshua A; Collier, Matthew B; Engh, C Anderson; Engh, Gerard A

    2006-04-01

    Shelf aging of gamma-irradiated-in-air polyethylene tibial components has been associated with increased articular surface wear and an elevated risk for revision. Nine hundred fifty cruciate-retaining inserts of one design were implanted between 1987 and 1996 (shelf age, 1.0 +/- 1.2 years). Less frequently used inserts (smallest/largest sizes, thicker thicknesses, supplemental articular constraint) had longer shelf ages (means ranged from 1.2 to 2.6 years). Survival analysis showed that shelf age (P product demand and can be of aid when diagnosing the painful knee.

  8. Midterm Survivorship and Complications of Total Knee Arthroplasty in Patients With Dwarfism.

    Science.gov (United States)

    Tan, Timothy L; Kheir, Michael M; Modi, Ronuk; Chen, Chi-Lung; Shao, Hongyi; Chen, Antonia F

    2017-11-01

    Dwarfism is associated with skeletal dysplasias and joint deformities that frequently result in osteoarthritis requiring treatment with total knee arthroplasty (TKA). These surgeries can be challenging because of alignment deformities, poor bone stock, and smaller components. This study aims to compare TKA implant survivorship and complications between dwarf and nondwarf patients. A retrospective case-control study was performed from 1997-2014 evaluating 115 TKAs in patients under the height threshold of 147.32 cm. This cohort was compared with 164 patients of normal height. Medical records were reviewed for demographics, surgical characteristics, and outcomes. All cases had 2-year minimum follow-up. The revision rate was 8.7% in dwarfs compared with 3.7% in controls (P = .08). The 2-, 5-, and 10-year implant survivorship in dwarfs was 96.4%, 92.5%, and 90.2%, respectively; and 96.6%, 95.6%, and 94.8% for controls, respectively (P = .24). Dwarfs underwent significantly more manipulations for arthrofibrosis (P = .002). There was greater femoral (17.4% vs 2.1%, P manipulation; the increased propensity for stiffness may be associated with oversized components, as evidenced by greater component overhang. Surgeons should be aware of this increased risk and may consider using smaller or customized implants to account for the morphological differences in this patient population. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Quality of life after total knee arthroplasty: systematic review.

    Science.gov (United States)

    da Silva, Robson Rocha; Santos, Ayrton André Melo; de Sampaio Carvalho Júnior, José; Matos, Marcos Almeida

    2014-01-01

    To review the literature on quality of life among patients who underwent total knee arthroplasty (TKA) and assess the impact of various associated factors. this was a systematic review of the literature in the Medline, Embase, Lilacs and SciELO databases, using the terms: TKA (total knee arthroplasty); TKR (total knee replacement); quality of life; and outcomes. There were no restrictions regarding study design. 31 articles addressing this topic using various quality-of-life evaluation protocols were selected. SF-36/SF-12, WOMAC and Oxford were the ones most frequently used. The studies made it possible to define that TKA is capable of making an overall improvement in patients' quality of life. Pain and function are among the most important predictors of improvement in quality of life, even when function remains inferior to that of healthy patients. The factors associated negatively were obesity, advanced age, comorbidities, persistence of pain after the procedure and a lengthy wait for surgery.

  10. Total Knee Arthroplasty for Knee Osteoarthritis: Support for a Foregone Conclusion?

    Science.gov (United States)

    Steinhaus, Michael E; Christ, Alexander B; Cross, Michael B

    2017-07-01

    Total knee arthroplasty (TKA) is generally accepted as the definitive treatment for advanced knee arthritis after patients fail nonoperative treatments; however, the safety and efficacy of TKA compared to continued nonoperative treatment has never been proven in high-quality, randomized controlled trials. Recently, a 2015 Danish study published a 12-month follow-up on a cohort of patients randomized to either a TKA or continued nonsurgical management for advanced knee osteoarthritis (OA). The authors reported significantly greater improvement in the TKA group in functional outcome scores such as the overall Knee Injury and Osteoarthritis Outcome Score (KOOS 4 score), the KOOS subscales, EQ-5D descriptive index, and timed get up-and-go and 20-m walk tests; however, patients in the TKA did suffer significantly more serious adverse events (SAE). The authors concluded that TKA combined with additional nonoperative care postoperatively is more efficacious than nonsurgical treatment alone in terms of improving pain, function, and quality of life at 12 months but is associated with more SAE. The purpose of this review is to identify the strengths and weaknesses of this trial, interpret its outcomes within the context of prior literature, and evaluate the validity of its conclusions.

  11. The trivector approach for minimally invasive total knee arthroplasty: a technical note.

    Science.gov (United States)

    Benazzo, Francesco; Rossi, Stefano Marco Paolo

    2012-09-01

    One of the main criticisms of minimally invasive approaches in total knee arthroplasty has been their poor adaptability in cases of major deformity or stiffness of the knee joint. When they are used in such cases, excessive soft-tissue tension is needed to provide appropriate joint exposure. Here, we describe the "mini trivector approach," which has become our standard approach for total knee replacement because it permits us to enlarge the indication for minimally or less invasive total knee replacement to many knees where quad sparing, a subvastus approach, or a mini quad or mini midvastus snip may not be sufficient to achieve correct exposure. It consists of a limited double snip of the VMO and the quadriceps tendon that reduces tension on the extensor mechanism and allows easier verticalization of the patella as well as good joint exposure.

  12. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experience with quality of care after a total hip or knee arthroplasty.

    NARCIS (Netherlands)

    Stubbe, J.H.; Gelsema, T.; Delnoij, D.M.J.

    2007-01-01

    Background: The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee) was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA) or total knee arthroplasty (TKA). The aim of this study is to evaluate the construct validity and internal

  13. Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis. A follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register.

    Science.gov (United States)

    Julin, Jaakko; Jämsen, Esa; Puolakka, Timo; Konttinen, Yrjö T; Moilanen, Teemu

    2010-08-01

    Total knee replacements (TKRs) are being increasingly performed in patients aged age of the patient and prosthesis survival following primary TKR using nationwide data collected from the Finnish Arthroplasty Register. From Jan 1, 1997 through Dec 31, 2003, 32,019 TKRs for primary or secondary osteoarthritis were reported to the Finnish Arthroplasty Register. The TKRs were followed until the end of 2004. During the follow-up, 909 TKRs were revised, 205 (23%) due to infection and 704 for other reasons. Crude overall implant survival improved with increasing age between the ages of 40 and 80. The 5-year survival rates were 92% and 95% in patients aged 65 years of age (p age groups 65 years remained after adjustment for these factors (p age impairs the prognosis of TKR and is associated with increased revision rates for non-infectious reasons. Diagnosis, sex, type of TKR, use of patellar component, and fixation method partly explain the differences, but the effects of physical activity, patient demands, and obesity on implant survival in younger patients warrant further research.

  14. Successful total knee arthroplasty in the presence of sporotrichal arthritis.

    NARCIS (Netherlands)

    Koeter, S.; Jackson, R.W.

    2006-01-01

    Articular sporotrichosis, a chronic granulomatous fungal infection, is a rare entity but when present may lead to significant joint destruction. Severe knee arthrosis due to sporotrichal arthritis has traditionally been treated with arthrodesis. Total knee arthroplasty in the presence of

  15. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    Science.gov (United States)

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Time-driven activity based costing of total knee replacement surgery at a London teaching hospital.

    Science.gov (United States)

    Chen, Alvin; Sabharwal, Sanjeeve; Akhtar, Kashif; Makaram, Navnit; Gupte, Chinmay M

    2015-12-01

    The aim of this study was to conduct a time-driven activity based costing (TDABC) analysis of the clinical pathway for total knee replacement (TKR) and to determine where the major cost drivers lay. The in-patient pathway was prospectively mapped utilising a TDABC model, following 20 TKRs. The mean age for these patients was 73.4 years. All patients were ASA grade I or II and their mean BMI was 30.4. The 14 varus knees had a mean deformity of 5.32° and the six valgus knee had a mean deformity of 10.83°. Timings were prospectively collected as each patient was followed through the TKR pathway. Pre-operative costs including pre-assessment and joint school were £ 163. Total staff costs for admission and the operating theatre were £ 658. Consumables cost for the operating theatre were £ 1862. The average length of stay was 5.25 days at a total cost of £ 910. Trust overheads contributed £ 1651. The overall institutional cost of a 'noncomplex' TKR in patients without substantial medical co-morbidities was estimated to be £ 5422, representing a profit of £ 1065 based on a best practice tariff of £ 6487. The major cost drivers in the TKR pathway were determined to be theatre consumables, corporate overheads, overall ward cost and operating theatre staffing costs. Appropriate discounting of implant costs, reduction in length of stay by adopting an enhanced recovery programme and control of corporate overheads through the use of elective orthopaedic treatment centres are proposed approaches for reducing the overall cost of treatment. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Identification of the critical level of implantation of an osseointegrated prosthesis for above-knee amputees.

    Science.gov (United States)

    Andrango Castro, Elder Michael; Konvickova, Svatava; Daniel, Matej; Horak, Zdenek

    2017-11-01

    The aim of our study was to identify potential critical levels of implantation of an osseointegrated prosthesis for above-knee amputees. The implant used was the OPRA system. It was inserted in the femur at four different amputation heights, characterized by their residual limb ratios (0.299, 0.44, 0.58 and 0.73). The stress and strain distribution was evaluated in the bone-implant system during walking, considering a body mass of 100 kg. Considerably high stimulus (11,489 με) in the tissue near the tip was found at the highest implantation level. All models presented small non-physiologic stress values in the tissue around the implant. The results revealed that the implantation level has a decisive effect on bone-implant performance. Mainly, the analysis indicates adverse biomechanical conditions for implantations in very short residual limbs.

  18. [Custom-designed 3D tibial augmentation for knee replacement].

    Science.gov (United States)

    Jirman, R; Vavrík, P; Horák, Z

    2009-02-01

    Reconstruction with the use of custom-made implants aims at optimal replacement of lost or damaged bone structures and restoration of their funkction. In this study the development and construction of a custom-made implant and the operative technique used for the treatment of an extensive tibial defect are described. The patient was a 65-year-old man treated for over 20 years for psoriatic arthritis and severe instability of the right knee, particularly in the frontal plane, with a worsening varus deformity. The radiogram showed an extensive destruction of the medial tibial condyle that also deeply involved the lateral condyle. The extent of defect made it impossible to use any commercial tibial augmentation. The geometry of the custom-designed implant for the medial tibial condyle was constructed on the basis of a 3D defect model and the shape of the medial tibial condyle of the collateral knee seen on CT scans. After its correct shape was verified on a plastic model, its coordinates were set in the software of a machine tool, and a titanium augmentation otherwise compatible with a standard knee replacement was produced.The use of such a custom implant to complete standard total knee arthroplasty has so far been demanding in terms of organisation and manufacture. Its production in the future could be facilitated by substituting titanium for plastic material such as poly-ether-ether-ketone (PEEK). Key words: custom-made implant, tibial augmentation, knee prosthesis.

  19. Total knee replacement influences both knee and hip joint kinematics during stair climbing

    OpenAIRE

    Saari, Tuuli; Tranberg, Roy; Zügner, Roland; Uvehammer, Johan; Kärrholm, Johan

    2004-01-01

    A gait analysis system was used to evaluate the kinematics of the hip and knee during stair ascending and descending after operation with total knee replacement. Patients with 5° varus/valgus alignment or less were selected randomly to receive either a flat or a concave tibial component with retention of the posterior cruciate ligament. Patients who had more than 5° varus/valgus alignment and/or an extension defect of 10° or more were selected randomly to receive the concave or posterior-stab...

  20. Does cruciate retention primary total knee arthroplasty affect proprioception, strength and clinical outcome?

    Science.gov (United States)

    Vandekerckhove, Pieter-Jan T K; Parys, Roel; Tampere, Thomas; Linden, Patrick; Van den Daelen, Luc; Verdonk, Peter C

    2015-06-01

    It remains unclear what the contribution of the PCL is in total knee arthroplasty (TKA). The goal of this study was to investigate the influence of the PCL in TKA in relationship to clinical outcome, strength and proprioception. Two arthroplasty designs were compared: a posterior cruciate-substituting (PS) and a posterior cruciate-retaining (CR) TKA. A retrospective analysis was performed of 27 CR and 18 PS implants with a minimum of 1 year in vivo. Both groups were compared in terms of clinical outcome (range of motion, visual analogue scale for pain, Hospital for Special Surgery Knee Scoring system, Lysholm score and Knee Injury and Osteoarthritis Outcome Score), strength (Biodex System 3 Dynamometer(®)) and proprioception (balance and postural control using the Balance Master system(®)). Each design was also compared to the non-operated contralateral side in terms of strength and proprioception. There were no significant differences between both designs in terms of clinical outcome and strength. In terms of proprioception, only the rhythmic weight test at slow and moderate speed shifting from left to right was significant in favour of the CR design. None of the unilateral stance tests showed any significant difference between both designs. There was no difference in terms of strength and proprioception between the operated side and the non-operated side. Retaining the PCL in TKA does not result in an improved performance in terms of clinical outcome and proprioception and does not show any difference in muscle strength. III.

  1. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    Science.gov (United States)

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  2. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  3. Preoperative methylprednisolone does not reduce loss of knee-extension strength after total knee arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Viktoria; Bandholm, Thomas Q; Zilmer, Camilla K

    2017-01-01

    tests, rescue analgesic requirements, and plasma C-reactive protein (CRP) changes. Results - 61 patients completed the follow-up. The loss in quadriceps muscle strength was similar between groups; group MP 1.04 (0.22-1.91) Nm/kg (-89%) vs. group C 1.02 (0.22-1.57) Nm/kg (-88%). Also between......-265) mg/L (p loss of knee-extension strength or other functional outcomes at discharge after fast-track TKA despite a reduced systemic inflammatory response.......Background and purpose - Patients undergoing total knee arthroplasty (TKA) face challenges related to postoperative reduction in knee-extension strength. We evaluated whether inhibition of the inflammatory response by a single preoperative dose of methylprednisolone (MP) reduces the pronounced loss...

  4. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  5. MR appearance of autologous chondrocyte implantation in the knee: correlation with the knee features and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tomoki [Department of Radiology and Institute of Orthopaedics, Oswestry, Shropshire (United Kingdom); Kumamoto University, Department of Orthopaedic and Neuro-Musculoskeletal Surgery, Kumamoto (Japan); Tins, Bernhard; McCall, Iain W.; Ashton, Karen [Department of Radiology and Institute of Orthopaedics, Oswestry, Shropshire (United Kingdom); Robert Jones and Agnes Hunt Orthopaedic Hospital NHS Trust, Department of Diagnostic Imaging, Oswestry, Shropshire (United Kingdom); Richardson, James B. [Department of Radiology and Institute of Orthopaedics, Oswestry, Shropshire (United Kingdom); RJAH Orthopaedic Hospital, Institute of Orthopaedics, Oswestry, Shropshire (United Kingdom); Takagi, Katsumasa [Department of Radiology and Institute of Orthopaedics, Oswestry, Shropshire (United Kingdom); Kumamoto Aging Research Institute, Kumamoto (Japan)

    2006-01-01

    To relate the magnetic resonance imaging (MRI) appearance of autologous chondrocyte implantation (ACI) in the knee in the 1st postoperative year with other knee features on MRI and with clinical outcome. Forty-nine examinations were performed in 49 patients at 1 year after ACI in the knee. Forty-one preoperative magnetic resonance (MR) examinations were also available. The grafts were assessed for smoothness, thickness in comparison with that of adjacent cartilage, signal intensity, integration to underlying bone and adjacent cartilage, and congruity of subchondral bone. Presence of overgrowth and bone marrow appearance beneath the graft were also assessed. Presence of osteophyte formation, further cartilage defects, appearance of the cruciate ligaments and the menisci were also recorded. An overall graft score was constructed, using the graft appearances. This was correlated with the knee features and the Lysholm score, a clinical self-assessment score. The data were analysed by a Kruskal-Wallis H test followed by a Mann-Whitney U test with Bonferroni correction as post-hoc test. Of 49 grafts, 32 (65%) demonstrated complete defect filling 1 year postoperatively. General overgrowth was seen in eight grafts (16%), and partial overgrowth in 13 grafts (26%). Bone marrow change underneath the graft was seen; oedema was seen in 23 grafts (47%), cysts in six grafts (12%) and sclerosis in two grafts (4%). Mean graft score was 8.7 (of maximal 12) (95% CI 8.0-9.5). Knees without osteophyte formation or additional other cartilage defects (other than the graft site) had a significantly higher graft score than knees with multiple osteophytes (P=0.0057) or multiple further cartilage defects (P=0.014). At 1 year follow-up improvement in the clinical scores was not significantly different for any subgroup. (orig.)

  6. Knee Kinematic Improvement After Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method

    Directory of Open Access Journals (Sweden)

    Hassan Sarailoo

    2013-10-01

    Full Text Available Objectives: The aim of this study was to extract suitable spatiotemporal and kinematic parameters to determine how Total Knee Replacement (TKR alters patients’ knee kinematics during gait, using a rapid and simplified quantitative two-dimensional gait analysis procedure. Methods: Two-dimensional kinematic gait pattern of 10 participants were collected before and after the TKR surgery, using a 60 Hz camcorder in sagittal plane. Then, the kinematic parameters were extracted using the gait data. A student t-test was used to compare the group-average of spatiotemporal and peak kinematic characteristics in the sagittal plane. The knee condition was also evaluated using the Oxford Knee Score (OKS Questionnaire to ensure thateach subject was placed in the right group. Results: The results showed a significant improvement in knee flexion during stance and swing phases after TKR surgery. The walking speed was increased as a result of stride length and cadence improvement, but this increment was not statistically significant. Both post-TKR and control groups showed an increment in spatiotemporal and peak kinematic characteristics between comfortable and fast walking speeds. Discussion: The objective kinematic parameters extracted from 2D gait data were able to show significant improvements of the knee joint after TKR surgery. The patients with TKR surgery were also able to improve their knee kinematics during fast walking speed equal to the control group. These results provide a good insight into the capabilities of the presented method to evaluate knee functionality before and after TKR surgery and to define a more effective rehabilitation program.

  7. Total knee replacement with tibial tubercle osteotomy in rheumatoid patients with stiff knee.

    Science.gov (United States)

    Eid, Ahmed Salem; Nassar, Wael Ahmed Mohamed; Fayyad, Tamer Abdelmeguid Mohamed

    2016-11-01

    Total knee arthroplasty (TKA) is a well-proven modality that can provide pain relief and restore mobility for rheumatoid arthritis (RA) patients with advanced joint destruction. Patellar ligament avulsion, especially in presence of poor bone quality and knee stiffness, is one of the special considerations that must be addressed in this unique population of patients. This study aimed to determine the functional results in a series of rheumatoid patients with stiff knee and end-stage joint destruction who underwent tibial tubercle osteotomy during TKA. Twenty-three knees in 20 patients (16 women; four men) at a mean age of 54 years with end-stage arthritis and knee stiffness due to RA were operated upon for TKA using tibial tubercle osteotomy as a step during the operation. Patients were reviewed clinically and radiographically with a minimum follow-up of two years. Complications were noted. Hospital for Special Surgery (HSS) score was recorded pre-operatively and at six and 12 months postoperatively. Union occurred at the osteotomy site in 21 of 23 cases. One case had deep venous thrombosis (DVT). There was no infection or periprosthetic fracture, and at last follow-up, no patient required revision. HSS score improved from 46 (15-60) pre-operatively to 85 (71-96) post-operatively. Tibial tubercle osteotomy during TKA in patients with RA and stiff knee is technically demanding yet proved to be effective in improving post-operative range of movement and minimising the complication of patellar ligament avulsion.

  8. Cross-linked polyethylene does not reduce wear in total knee arthroplasty.

    Science.gov (United States)

    Lasurt-Bachs, S; Torner, P; Maculé, F; Prats, E; Menéndez-García, F; Ríos-Guillermo, J; Torrents, A

    To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ 2 =0.19; P=.66) or rounded (χ 2 =1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender.

    Science.gov (United States)

    Nassif, Jeffrey M; Pietrzak, William S

    2015-01-01

    While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN) in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6-5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1) and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2) were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  10. Biomechanical analysis of posterior cruciate ligament retaining high-flexion total knee arthroplasty

    NARCIS (Netherlands)

    Zelle, J.; van der Zanden, A.C.; De Waal Malefijt, M.; Verdonschot, Nicolaas Jacobus Joseph

    2009-01-01

    Background High-flexion knee replacements have been developed to accommodate a large range of flexion (>120°) after total knee arthroplasty. Both posterior cruciate ligament retaining and sacrificing high-flexion knee designs have been marketed. The main objective of this study was to evaluate the

  11. Do patients care about higher flexion in total knee arthroplasty?

    DEFF Research Database (Denmark)

    Thomsen, Morten G; Husted, Henrik; Otte, Kristian Stahl

    2013-01-01

    BACKGROUND: Little information exists to support that patients care about flexion beyond what is needed to perform activities of daily living (ADL) after Total knee arthroplasty (TKA). The purpose of this study was to investigate if the achievement of a higher degree of knee flexion after TKA would...

  12. Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics : a musculoskeletal simulation study

    NARCIS (Netherlands)

    Marra, Marco Antonio; Strzelczak, Marta; Heesterbeek, Petra J.C.; van de Groes, Sebastiaan A.W.; Janssen, Dennis W.; Koopman, Bart F.J.M.; Wymenga, Ate B.; Verdonschot, Nico J.J.

    2017-01-01

    Purpose: In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior

  13. Outcome of revision total knee arthroplasty with the use of trabecular metal cone for reconstruction of severe bone loss at the proximal tibia

    DEFF Research Database (Denmark)

    Jensen, Claus L; Olsen, Nikolaj Winther; Schrøder, Henrik M

    2014-01-01

    technology (TMT) cones for the reconstruction of tibial bone loss at the time of rTKA. METHODS: Thirty-six patients had rTKA with the use of a TMT Cone. Bone loss was classified according to the AORI classification and 25% of the patients suffered from T3 AORI defects and 75% of the patients from T2 AORI...... defects. Implants used were from the NexGen series. At follow-up, radiographs were evaluated according to the Knee Society Roentgenographic Scoring System. Knee and function score was calculated using the Knee Society Clinical Rating System. Average follow-up time was 47 months (range 3-84 months......BACKGROUND: The relative effectiveness of different methods for reconstructing large bone loss at the proximal tibia in revision total knee arthroplasty (rTKA) has not been established. The aim of this study was to evaluate the clinical and radiological outcome after the use of trabecular metal...

  14. Cemented total knee replacement in 24 dogs: surgical technique, clinical results, and complications.

    Science.gov (United States)

    Allen, Matthew J; Leone, Kendall A; Lamonte, Kimberly; Townsend, Katy L; Mann, Kenneth A

    2009-07-01

    To characterize the performance of cemented total knee replacement (TKR) in dogs. Preclinical research study. Skeletally mature, male Hounds (25-30 kg; n=24) with no preexisting joint pathology. Dogs had unilateral cemented TKR and were evaluated at 6, 12, 26, or 52 weeks (6 dogs/time point) by radiography, bone density analysis, visual gait assessment, and direct measurement of thigh circumference and stifle joint range of motion as indicators of functional recovery. At study end, the stability of the cemented tibial component was determined by destructive mechanical testing. Joint stability was excellent in 16 dogs (67%) and good in 8 dogs. None of the tibial components had evidence of migration or periprosthetic osteolysis whereas 1 femoral component was loose at 52 weeks. There was an early and significant decrease in tibial bone density, likely because of disuse of the operated limb. Dogs returned to full activity by 12 weeks. The tibial cement-bone interface maintained its strength over 52 weeks. Cement provides stable fixation of the tibial component in canine TKR. Cemented TKR yields adequate clinical function and stifle joint excursion in the dog. Clinical studies are needed to determine the long-term fate of cemented TKR implants, to assess the influence of implant design on implant fixation and wear, and to obtain objective functional data.

  15. [Use of Patient Specific Instruments at Total Knee Arthroplasty. One-Year Results of a Prospective Randomised Study].

    Science.gov (United States)

    Musil, D; Stehlík, J; Abrman, K; Held, M; Sadovský, P

    2016-01-01

    -operative planning and more accurate implant sizing and alignment. An experienced surgeon can achieve the same good results with conventional planning under standard conditions but the use of PSIs is clearly more beneficial in patients with extra-articular deformities and in patients in whom femoral intramedullary guides cannot be employed. To produce a custom-made pin guide requires a CT scan of the whole leg and is also associated with additional paperwork. The PSIs simplify the total knee process from start to finish and surgeons have complete flexibility to make fine-tuning adjustments during the procedure. CONCLUSIONS Zimmer Patient Specific Instruments allow for exact alignment of both the femoral and the tibial component in a TKA process. Under standard circumstances, clinical and radiographic outcomes are comparable with those of conventional planning. However, the use of PSIs is clearly more beneficial in patients with extra-articular deformities and in patients in whom femoral intramedullary guides cannot be employed. total knee arthroplasty, TKA, Patient Specific Instruments, PSIs.

  16. Effects of total knee arthroplasty on ankle alignment in patients with varus gonarthrosis: Do we sacrifice ankle to the knee?

    Science.gov (United States)

    Gursu, Sarper; Sofu, Hakan; Verdonk, Peter; Sahin, Vedat

    2016-08-01

    Total knee arthroplasty is one of the most commonly preferred surgical methods in the treatment of patients with varus gonarthrosis. In this study, we aimed to evaluate the radiological changes observed in the ankles after total knee arthroplasty. Between May 2012 and June 2013, 80 knees of 78 patients with varus deformity over 10° underwent total knee arthroplasty. For each patient, full-leg standing radiographs were obtained pre- and post-operatively. Mechanical and anatomical axes (HKA and AA), lateral distal femoral angle, medial proximal tibial angle, lateral distal tibial angle (LDTA), ankle joint line orientation angle (AJOA), tibial plafond talus angle (PTA) and talar shift were measured for each patient both pre- and post-operatively. Pre-operatively, the mean HKA was 16.6° and the mean AA was 10.41°, both in favour of varus alignment. Post-operatively, the mean HKA decreased to 3.6° and the mean AA to -2.1. The mean LDTA was 87.3°. Before the operation, the mean AJOA was -7.6°, opening to the medial aspect of the ankle, and it was 0.04° after the operation and opening to the lateral aspect (p < 0.05). Our study reveals the changes occurring in the ankle after acute correction of long-standing varus deformity of the knee using total knee arthroplasty. In cases undergoing knee arthroplasty, effect of the acute change in the alignment of the knee on the ankle should be taken into consideration and the amount of correction should be calculated carefully in order not to damage the alignment of the ankle. IV.

  17. The value of FDG-PET in patients with painful total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Stumpe, Katrin D.M.; Schulthess, Gustav K. von; Strobel, Klaus [University Hospital, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Romero, Jose [Orthopaedic University Hospital Balgrist, Orthopaedic Surgery, Zurich (Switzerland); Center for Joint Diseases at Hirslanden Clinic, EndoClinic Zurich, Zurich (Switzerland); Ziegler, Oliver [Orthopaedic University Hospital Balgrist, Orthopaedic Surgery, Zurich (Switzerland); Ortho Zentrum Rosenheim, Rosenheim (Germany); Kamel, Ehab M. [University Hospital, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Centre Hospitalier Universitaire Vaudois (CHUV), Division of Nuclear Medicine, Lausanne (Switzerland); Hodler, Juerg [Orthopaedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland)

    2006-10-15

    The purpose of this study was to evaluate{sup 18}F-fluorodeoxyglucose (FDG) uptake in patients with painful total knee arthroplasty and to relate FDG uptake to the location of soft tissue pain. Twenty-eight patients with painful total knee arthroplasty had a clinical examination, standard radiographs, CT measurement of rotation of the femoral component and FDG-PET (18 PET/CT, 10 PET). The diagnosis of infection was based on microbiological examinations of surgical specimens (n=12) or clinical follow-up for at least 6 months (n=16),{sup 99m}Tc-labelled monoclonal antibody scintigraphy and joint aspiration. Twenty-seven of 28 patients presented with diffuse synovial FDG uptake. Additional focal extrasynovial FDG uptake was observed in 19 knees. Twenty-four of the 28 patients had a diagnosis of internal femoral malrotation. The remaining four patients showed no rotation (0 ) and 3 , 4 and 7 of external rotation, respectively. Three patients presented with the additional diagnosis of an infected total knee replacement. Pain was described as diffuse (n=10) or focal (n=18). In two knees a relationship between pain location and FDG uptake was observed. Of ten patients with a severe internal femoral component rotation (>6 ), seven had focal uptake, four in the femoral periosteum and three in the tibial periosteum. The difference between knees with severe malrotation and the remaining knees was not significant (p=1.000, Fisher's Exact Test). Diffuse synovial and focal extrasynovial FDG-PET uptake is commonly found in patients with malrotation of the femoral component and is not related to pain location. The information provided by FDG-PET does not contribute to the diagnosis and management of individual patients with persistent pain after total knee replacement. (orig.)

  18. The value of FDG-PET in patients with painful total knee arthroplasty

    International Nuclear Information System (INIS)

    Stumpe, Katrin D.M.; Schulthess, Gustav K. von; Strobel, Klaus; Romero, Jose; Ziegler, Oliver; Kamel, Ehab M.; Hodler, Juerg

    2006-01-01

    The purpose of this study was to evaluate 18 F-fluorodeoxyglucose (FDG) uptake in patients with painful total knee arthroplasty and to relate FDG uptake to the location of soft tissue pain. Twenty-eight patients with painful total knee arthroplasty had a clinical examination, standard radiographs, CT measurement of rotation of the femoral component and FDG-PET (18 PET/CT, 10 PET). The diagnosis of infection was based on microbiological examinations of surgical specimens (n=12) or clinical follow-up for at least 6 months (n=16), 99m Tc-labelled monoclonal antibody scintigraphy and joint aspiration. Twenty-seven of 28 patients presented with diffuse synovial FDG uptake. Additional focal extrasynovial FDG uptake was observed in 19 knees. Twenty-four of the 28 patients had a diagnosis of internal femoral malrotation. The remaining four patients showed no rotation (0 ) and 3 , 4 and 7 of external rotation, respectively. Three patients presented with the additional diagnosis of an infected total knee replacement. Pain was described as diffuse (n=10) or focal (n=18). In two knees a relationship between pain location and FDG uptake was observed. Of ten patients with a severe internal femoral component rotation (>6 ), seven had focal uptake, four in the femoral periosteum and three in the tibial periosteum. The difference between knees with severe malrotation and the remaining knees was not significant (p=1.000, Fisher's Exact Test). Diffuse synovial and focal extrasynovial FDG-PET uptake is commonly found in patients with malrotation of the femoral component and is not related to pain location. The information provided by FDG-PET does not contribute to the diagnosis and management of individual patients with persistent pain after total knee replacement. (orig.)

  19. Preserving the PCL during the tibial cut in total knee arthroplasty.

    Science.gov (United States)

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  20. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender

    Directory of Open Access Journals (Sweden)

    Jeffrey M. Nassif

    2015-01-01

    Full Text Available While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6–5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1 and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2 were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  1. BIOMECHANICAL INDICES OF STANDING AND GAIT IN PATIENTS AFTER TOTAL KNEE REPLACEMENT USING COMPUTER NAVIGATION

    Directory of Open Access Journals (Sweden)

    Y. A. Bezgodkov

    2011-01-01

    Full Text Available Several biomechanical parameters of standing and walking in 50 patients with osteoarthrosis after total knee arthroplasty were evaluated. The patients were randomly divided in two equal groups: in the first group the surgery was performed with computer navigation system and in the second - with traditional instruments. After TKA with computer navigation centers of common body pressure and legs pressure during standing phase improved significantly better than in traditional group. Walking parameters like step length, ground contact time and rhythm coefficient improved in both groups of patients but without significant difference. Thereby more precise orientation of implant that achieved during computer assisted TKA leads to better functional performance at 6 and 12 month after surgery.

  2. Displays mounted on cutting blocks reduce the learning curve in navigated total knee arthroplasty.

    Science.gov (United States)

    Schnurr, Christoph; Eysel, Peer; König, Dietmar Pierre

    2011-01-01

    The use of computer navigation in total knee arthroplasty (TKA) improves the implant alignment but increases the operation time. Studies have shown that the operation time is further prolonged due to the surgeon's learning curve, and longer operation times have been associated with higher morbidity risks. It has been our hypothesis that an improvement in the human-machine interface might reduce the time required during the learning curve. Accordingly, we asked whether the use of navigation devices with a display fixed on the surgical instruments would reduce the operation time in navigated TKAs performed by navigation beginners. Thirty medical students were randomized and used two navigation devices in rotation: these were the Kolibri® device with an external display and the Dash® device with a display that was fixed on the cutting blocks. The time for adjustment of the tibial and femoral cutting blocks on knee models while using these devices was measured. A significant time reduction was demonstration when the Dash® device was used: The time reduction was 21% for the tibial block (p = 0.007), 40% for the femoral block (p learning curve may be diminished.

  3. Soft-tissue tension total knee arthroplasty.

    Science.gov (United States)

    Asano, Hiroshi; Hoshino, Akiho; Wilton, Tim J

    2004-08-01

    It is far from clear how best to define the proper strength of soft-tissue tensioning in total knee arthroplasty (TKA). We attached a torque driver to the Monogram balancer/tensor device and measured soft-tissue tension in full extension and 90 degrees flexion during TKA. In our surgical procedure, when we felt proper soft-tissue tension was being applied, the mean distraction force was noted to be 126N in extension and 121N in flexion. There was no significant correlation between soft-tissue tension and the postoperative flexion angle finally achieved. To the best of our knowledge, this is the first study to assess the actual distraction forces in relation to soft-tissue tension in TKA. Further study may reveal the most appropriate forces to achieve proper soft-tissue tension in the wide variety of circumstances presenting at knee arthroplasty.

  4. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  5. A Systematic Review of Clinical Functional Outcomes After Medial Stabilized Versus Non-Medial Stabilized Total Knee Joint Replacement

    Directory of Open Access Journals (Sweden)

    Tony Young

    2018-04-01

    Full Text Available Background Medial stabilized total knee joint replacement (TKJR construct is designed to closely replicate the kinematics of the knee. Little is known regarding comparison of clinical functional outcomes of patients utilising validated patient reported outcome measures (PROM after medial stabilized TKJR and other construct designs.PurposeTo perform a systematic review of the available literature related to the assessment of clinical functional outcomes following a TKJR employing a medial stabilized construct design.MethodsThe review was performed with a Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA algorithm. The literature search was performed using variouscombinations of keywords. The statistical analysis was completed using Review Manager (RevMan, Version 5.3.ResultsIn the nineteen unique studies identified, there were 2,448 medial stabilized TKJRs implanted in 2,195 participants, there were 1,777 TKJRs with non-medial stabilized design constructs implanted in 1,734 subjects. The final mean Knee Society Score (KSS value in the medial stabilized group was 89.92 compared to 90.76 in the non-medial stabilized group, with the final KSS mean value difference between the two groups was statistically significant and favored the non-medial stabilized group (SMD 0.21; 95% CI: 0.01 to 0.41; p = 004. The mean difference in the final WOMAC values between the two groups was also statistically significant and favored the medial stabilized group (SMD: −0.27; 95% CI: −0.47 to −0.07; p = 0.009. Moderate to high values (I2 of heterogeneity were observed during the statistical comparison of these functional outcomes.ConclusionBased on the small number of studies with appropriate statistical analysis, we are unable to reach a clear conclusion in the clinical performance of medial stabilized knee replacement construct.Level of EvidenceLevel II

  6. The patient's experience of temporary paralysis from spinal anaesthesia, a part of total knee replacement

    DEFF Research Database (Denmark)

    Bager, Louise; Konradsen, Hanne; Dreyer, Pia Sander

    2015-01-01

    AIMS AND OBJECTIVES: The aim of this study was to describe the meaning of being temporary paralysed from spinal anaesthesia when undergoing total knee replacement. BACKGROUND: Total knee arthroplasty is a common procedure, and regional anaesthesia is used as a method for anaesthetising the patient...... of the experience of spinal anaesthesia, as a part of having a total knee replacement. METHODS: Twelve patients were interviewed in March 2014 after undergoing an elective total knee arthroplasty under spinal anaesthesia. The interviews were analysed with a Ricoeur-inspired interpretation method. RESULTS: Three...... TO CLINICAL PRACTICE: The results of this study contribute to insights and deeper knowledge that can enhance staff's ability to provide care for patients undergoing total knee arthroplasty in spinal anaesthesia. The results provide perspectives that argue for care in accordance to individual needs....

  7. The Warwick patellofemoral arthroplasty trial: a randomised clinical trial of total knee arthroplasty versus patellofemoral arthroplasty in patients with severe arthritis of the patellofemoral joint

    Directory of Open Access Journals (Sweden)

    Odumenya Michelle

    2011-11-01

    Full Text Available Abstract Background Severe arthritis of the knee is a disabling condition, with over 50,000 knee replacements performed each year in the UK. Isolated patellofemoral joint arthritis occurs in over 10% of these patients with the treatment options being patellofemoral arthroplasty or total knee arthroplasty. Whilst many surgeons believe total knee arthroplasty is the 'gold standard' treatment for severe knee arthritis, patellofemoral arthroplasty has certain potential advantages. Primarily, because this operation allows the patient to keep the majority of their own knee joint; preserving bone-stock and the patients' own ligaments. Patellofemoral arthroplasty has also been recognised as a less 'invasive' operation than primary total knee arthroplasty, facilitating a more rapid recovery. There are currently no published results of randomised clinical trials comparing the two arthroplasty techniques. The primary objective of the current study is to assess whether there is a difference in functional knee scores and quality of life outcome assessments at one year post-operation between patellofemoral arthroplasty and total knee arthroplasty. The secondary objective is to assess the complication rates for both procedures. Methods/design Patients who are deemed suitable, by an Orthopaedic Consultant, for patellofemoral arthroplasty and medically fit for surgery are eligible to take part in this trial. The consenting patients will be randomised in a 1:1 allocation to a total knee or patellofemoral arthroplasty. The randomisation sequence will be computer generated and administered by a central independent randomisation service. Following consent, all participants will have their knee function, quality of life and physical activity level assessed through questionnaires. The assigned surgery will then be performed using the preferred technique and implant of the operating surgeon. The first post-operative assessments will take place at six weeks, followed by

  8. Multi-ligament instability after early dislocation of a primary total knee replacement - case report.

    Science.gov (United States)

    Sisak, Krisztian; Lloyd, John; Fiddian, Nick

    2011-01-01

    Peripheral nerve blocks have found increased popularity in providing prolonged post-operative analgesia following total knee replacement surgery. They generally provide effective analgesia with fewer complications than epidurals. This report describes an acute low-energy knee dislocation after a well balanced, fixed bearing, cruciate-retaining primary total knee replacement performed under a spinal anaesthetic with combined complimentary femoral and sciatic nerve blocks. The dislocation was not accompanied by neurovascular compromise. Due to the subsequent instability and injury to both collaterals, the posterior cruciate ligament and posterolateral corner structures, the knee was treated with a rotating-hinge revision total knee replacement. The dislocation occurred whilst the peripheral nerve blocks (PNB) were still working. We review our incidence of PNB related complications and conclude that PNB remain a safe and effective analgesia for total knee replacements. However, we advocate that ward staff and patients should be sufficiently educated to ensure that unaided post-operative mobilisation is prevented until such a time that patients have regained complete voluntary muscle control. Copyright © 2009 Elsevier B.V. All rights reserved.

  9. Can total knee arthroplasty (TKA) achieve its goal in knee flexion floor activity of Thai Buddhist monks?

    Science.gov (United States)

    Sresuriyasawad, Viriya

    2012-10-01

    To study knee's angulation required for Thai Buddhist monks whose activity based on floor sitting basis. And to identify an inter-observer reliability of knee flexion measurement based on radiologic reading. Descriptive analysis study comprised of measuring bilateral knee flexing angulation in 4 postures of floor activities; kneeling, monk's position in both right and left manner and sit cross-legged position, in 35 Thai Buddhist monks at Priest Hospital using plain radiograph image. The radiograph imaging for each patient was performed by one radiologist and two orthopedics. The measurement result was also analyzed for inter-observer reliability. Mean knee flexion angle in kneel, left monk's position, right monk's position and sit cross-legged postures were 163.21, 146.49, 148.89 and 138.38 degree, respectively. No statistical difference between knee flexion measurements among 3 investigators. Daily floor activity of Thai Buddhist monks need more flexion capacity than that can achieve by total knee arthroplasty instrument using nowadays.

  10. A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique.

    Science.gov (United States)

    Øhrn, Frank-David; Van Leeuwen, Justin; Tsukanaka, Masako; Röhrl, Stephan M

    2018-05-09

    Background and purpose - There is some concern regarding the revision rate of the Vanguard CR TKA in 1 registry, and the literature is ambiguous about the efficacy of patient-specific positioning guides (PSPGs). The objective of this study was to investigate the stability of the cemented Vanguard CR Total Knee using 2 different surgical techniques. Our hypothesis was that there is no difference in migration when implanting the Vanguard CR with either PSPGs or conventional technique. We hereby present a randomized controlled trial of 2-year follow-up with radiostereometric analysis (RSA). Patients and methods - 40 TKAs were performed between 2011 and 2013 with either PSPGs or the conventional technique and 22 of these were investigated with RSA. Results - The PSPG (8 knees) and the conventional (14 knees) groups had a mean maximum total point motion (MTPM) (95% CI) of 0.83 (0.48-1.18) vs. 0.70 (0.43-0.97) mm, 1.03 (0.60-1.43) vs. 0.86 (0.53-1.19), and 1.46 (1.07-1.85) vs. 0.80 (0.52-1.43) at 3, 12, and 24 months respectively (p = 0.1). 5 implants had either an MTPM >1.6 mm at 12 months and/or a migration of more than 0.2 mm between 1- and 2-year follow-ups. 2 of these also had a peripheral subsidence of more than 0.6 mm at 2 years. Interpretation - 5 implants (3 in the PSPG group) were found to be at risk of later aseptic loosening. The PSPG group continuously migrated between 12 and 24 months. The conventional group had an initial high migration between postoperative and 3 months, but seemed more stable after 1 year. Although the difference was not statistically significant, we think the migration in the PSPG group is of some concern.

  11. Template-Directed Instrumentation Reduces Cost and Improves Efficiency for Total Knee Arthroplasty: An Economic Decision Analysis and Pilot Study.

    Science.gov (United States)

    McLawhorn, Alexander S; Carroll, Kaitlin M; Blevins, Jason L; DeNegre, Scott T; Mayman, David J; Jerabek, Seth A

    2015-10-01

    Template-directed instrumentation (TDI) for total knee arthroplasty (TKA) may streamline operating room (OR) workflow and reduce costs by preselecting implants and minimizing instrument tray burden. A decision model simulated the economics of TDI. Sensitivity analyses determined thresholds for model variables to ensure TDI success. A clinical pilot was reviewed. The accuracy of preoperative templates was validated, and 20 consecutive primary TKAs were performed using TDI. The model determined that preoperative component size estimation should be accurate to ±1 implant size for 50% of TKAs to implement TDI. The pilot showed that preoperative template accuracy exceeded 97%. There were statistically significant improvements in OR turnover time and in-room time for TDI compared to an historical cohort of TKAs. TDI reduces costs and improves OR efficiency. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Total replace in the knee with deformity in the valgus

    International Nuclear Information System (INIS)

    Lara Cortassio, Gilberto; Pineros Ramirez, Daniel Francisco

    2006-01-01

    The total knee arthroplasty with valgus deformity is a technically demanding surgery. The bone deformities and the soft tissues make difficult to balance the soft tissues, the mechanic axis restoration and the prostheses placement. We present the results of a retrospective study, observational, descriptive type series of cases of 40 patients (42 prostheses), operated on with valgus deformity of more than 10 grades, using the I. White side technique to balance the soft tissue, with and average following up of 4.5 years. Based on the knee society scale (KSS) we found satisfactory results in more than 92% of the cases (39 prostheses). The complications were: total lost of the knee extension in 2 patients and i femoropatellar misalignment. We recommend practicing a sequential liberation of the lateral soft tissue to obtain a good clinical result and prostheses longevity

  13. The role of pain for early rehabilitation in fast track total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten Tange; Myhrmann, Lis

    2010-01-01

    To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA).......To investigate the relationship between early functional mobility and pain intensity in a fast track program after total knee arthroplasty (TKA)....

  14. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

    Science.gov (United States)

    Howell, Stephen M; Hodapp, Esther E; Vernace, Joseph V; Hull, Maury L; Meade, Thomas D

    2013-10-01

    Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.

  15. Correction of tibial malunion in a patient with ipsilateral total knee and ankle prostheses using external ring fixation and the ilizarov method

    Directory of Open Access Journals (Sweden)

    Alexander M Smith

    2017-01-01

    Full Text Available Total ankle replacement (TAR aims at reestablishing a functional and painless ankle joint while maintaining motion and preventing adjacent joint arthritis. TAR can be complicated by comorbidities such as ipsilateral knee arthritis and deformity with subsequent arthroplasty and/or other lower extremity malalignment issues. We present a case of a 67-year-old female with severe right ankle pain and a history of ipsilateral subtalar and calcaneocuboid fusion, bilateral total knee arthroplasty, and a malunion of a conservatively treated ipsilateral segmental tibial fracture. Following TAR, there was recurrent lateral hindfoot pain due to subtle malalignment from the tibial malunion which resulted in persistent hindfoot valgus. This caused symptomatic subfibular impingement in addition to limb length discrepancy. To address that, a circular external fixator was applied to realign the ankle and lengthen the tibia, eliminating pain and avoiding complications with either implant.

  16. Knee joint biomechanics and neuromuscular control during gait before and after total knee arthroplasty are sex-specific.

    Science.gov (United States)

    Astephen Wilson, Janie L; Dunbar, Michael J; Hubley-Kozey, Cheryl L

    2015-01-01

    The future of total knee arthroplasty (TKA) surgery will involve planning that incorporates more patient-specific characteristics. Despite known biological, morphological, and functional differences between men and women, there has been little investigation into knee joint biomechanical and neuromuscular differences between men and women with osteoarthritis, and none that have examined sex-specific biomechanical and neuromuscular responses to TKA surgery. The objective of this study was to examine sex-associated differences in knee kinematics, kinetics and neuromuscular patterns during gait before and after TKA. Fifty-two patients with end-stage knee OA (28 women, 24 men) underwent gait and neuromuscular analysis within the week prior to and one year after surgery. A number of sex-specific differences were identified which suggest a different manifestation of end-stage knee OA between the sexes. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Contact Kinematics Correlates to Tibial Component Migration Following Single Radius Posterior Stabilized Knee Replacement.

    Science.gov (United States)

    Teeter, Matthew G; Perry, Kevin I; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-03-01

    Contact kinematics between total knee arthroplasty components is thought to affect implant migration; however, the interaction between kinematics and tibial component migration has not been thoroughly examined in a modern implant system. A total of 24 knees from 23 patients undergoing total knee arthroplasty with a single radius, posterior stabilized implant were examined. Patients underwent radiostereometric analysis at 2 and 6 weeks, 3 and 6 months, and 1 and 2 years to measure migration of the tibial component in all planes. At 1 year, patients also had standing radiostereometric analysis examinations acquired in 0°, 20°, 40°, and 60° of flexion, and the location of contact and magnitude of any condylar liftoff was measured for each flexion angle. Regression analysis was performed between kinematic variables and migration at 1 year. The average magnitude of maximum total point motion across all patients was 0.671 ± 0.270 mm at 1 year and 0.608 ± 0.359 mm at 2 years (P = .327). Four implants demonstrated continuous migration of >0.2 mm between the first and second year of implantation. There were correlations between the location of contact and tibial component anterior-posterior tilt, varus-valgus tilt, and anterior-posterior translation. The patients with continuous migration demonstrated atypical kinematics and condylar liftoff in some instances. Kinematics can influence tibial component migration, likely through alterations of force transmission. Abnormal kinematics may play a role in long-term implant loosening. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A randomised, controlled trial of circumpatellar electrocautery in total knee replacement without patellar resurfacing.

    Science.gov (United States)

    van Jonbergen, H P W; Scholtes, V A B; van Kampen, A; Poolman, R W

    2011-08-01

    The efficacy of circumpatellar electrocautery in reducing the incidence of post-operative anterior knee pain is unknown. We conducted a single-centre, outcome-assessor and patient-blinded, parallel-group, randomised, controlled trial to compare circumpatellar electrocautery with no electrocautery in total knee replacement in the absence of patellar resurfacing. Patients requiring knee replacement for primary osteoarthritis were randomly assigned circumpatellar electrocautery (intervention group) or no electrocautery (control group). The primary outcome measure was the incidence of anterior knee pain. A secondary measure was the standardised clinical and patient-reported outcomes determined by the American Knee Society scores and the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index. A total of 131 knees received circumpatellar electrocautery and 131 had no electrocautery. The overall incidence of anterior knee pain at follow-up at one year was 26% (20% to 31%), with 19% (12% to 26%) in the intervention group and 32% (24% to 40%) in the control group (p = 0.02). The relative risk reduction from electrocautery was 40% (9% to 61%) and the number needed to treat was 7.7 (4.3 to 41.4). The intervention group had a better mean total WOMAC score at follow-up at one year compared with the control group (16.3 (0 to 77.7) versus 21.6 (0 to 76.7), p = 0.04). The mean post-operative American Knee Society knee scores and function scores were similar in the intervention and control groups (knee score: 92.4 (55 to 100) versus 90.4 (51 to 100), respectively (p = 0.14); function score: 86.5 (15 to 100) versus 84.5 (30 to 100), respectively (p = 0.49)). Our study suggests that in the absence of patellar resurfacing electrocautery around the margin of the patella improves the outcome of total knee replacement.

  19. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  20. No positive effect of autologous platelet gel after total knee arthroplasty

    NARCIS (Netherlands)

    Peerbooms, Joost C.; de Wolf, Gideon S.; Colaris, Joost W.; Bruijn, Daniël J.; Verhaar, Jan A. N.

    2009-01-01

    Activated platelets release a cocktail of growth factors, some of which are thought to stimulate repair. We investigated whether the use of autologous platelet gel (PG) in total knee arthroplasty (TKA) would improve wound healing and knee function, and reduce blood loss and the use of analgesics.

  1. Quality assessment before and after knee replacement

    Directory of Open Access Journals (Sweden)

    Paweł Węgorowski

    2017-07-01

    On the basis of the research, it was concluded that the main cause of the implantation of the prosthesis was a knee injury (54%. The disease affected the deterioration of physical fitness prior to implantation of knee arthroplasty in 28% of respondents; 34% said they were very good. The quality of life after implantation of knee arthroplasty significantly improved in 57% of respondents. Self-service after surgery has improved considerably in 23% of respondents.

  2. Radiologic findings in cases involving complications arising from total knee arthroplasty

    International Nuclear Information System (INIS)

    Nam, Deok Ho; Ryu, Kyung Nam; Bae, Dae Kyung

    1999-01-01

    Total knee arthroplasty(TKA) has been used for the treatment of knee joint pain, deformity, and instability caused by osteoarthritis, rheumatoid arthritis, or tuberculous arthritis, and by virtue of good results and rapid development, the procedure has been increasingly employed. With the development of total knee prosthesis, complications have also increased, however, and due to complications occurring up to six years after surgery, fusion occurs in about 2% of all replaced knees. The most common complication of TKA is loosening, followed by infection. Others are thrombosis, subluxation, dislocation and fracture, and complications may be divided into four groups: biologic, technical, specific to type of components, and associated with certain diagnosis. Where these complications occur, a patient must undergo a second procedure, but the success rate is lower than for the initial procedure. Exact etiological evaluation important clinically and radiologically. We illustrate the etiologies and radiologic characteristics of TKA complications according to classification

  3. Radiologic findings in cases involving complications arising from total knee arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Deok Ho; Ryu, Kyung Nam; Bae, Dae Kyung [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1999-09-01

    Total knee arthroplasty(TKA) has been used for the treatment of knee joint pain, deformity, and instability caused by osteoarthritis, rheumatoid arthritis, or tuberculous arthritis, and by virtue of good results and rapid development, the procedure has been increasingly employed. With the development of total knee prosthesis, complications have also increased, however, and due to complications occurring up to six years after surgery, fusion occurs in about 2% of all replaced knees. The most common complication of TKA is loosening, followed by infection. Others are thrombosis, subluxation, dislocation and fracture, and complications may be divided into four groups: biologic, technical, specific to type of components, and associated with certain diagnosis. Where these complications occur, a patient must undergo a second procedure, but the success rate is lower than for the initial procedure. Exact etiological evaluation important clinically and radiologically. We illustrate the etiologies and radiologic characteristics of TKA complications according to classification.

  4. Midterm Outcomes of High-flexion Total Knee Arthroplasty on Japanese Lifestyle

    OpenAIRE

    Ohno, Hiroshi; Murata, Minoru; Ozu, Satoshi; Matsuoka, Nariyasu; Kawamura, Hiroshi; Iida, Hirokazu

    2018-01-01

    Objectives: To evaluate the clinical outcomes after total knee arthroplasty (TKA) using the Genesis II posterior stabilized prosthesis with a high-flex insert during the mid-term follow-up and to assess its effect on the Japanese lifestyle. Materials and Methods: Fifty-three consecutive patients (8 men and 45 women) underwent primary TKA. The mean follow-up duration was 76 months (5-9 years). We evaluated the Japanese Orthopedic Association osteoarthritis knee rating score (JOA knee score), r...

  5. Combined osteoplasty of metaepiphysial defects in total knee arthroplasty with osteoplastic biomaterial

    Directory of Open Access Journals (Sweden)

    Gavrilov М.А.

    2012-12-01

    Full Text Available The research goal is to study the results of osteoplastic biomaterials application to reach the improvement of primary and long-term secondary stability of fixation. Materials and methods: 62 patients with bone defect of metaepiphy-sis of type 2 according to AORI have been included into the research. Total knee arthroplasty with osteoplasty of the defect has been carried out in all the patients. In the basic group (n=32 combined osteoplasty has been used, and in comparison group (n=30 cement osteoplasty has been applied. In cases with total arthroplasty in the basic group modifying standard resections, structural autograft of laminar form has been received simultaneously. After preparing the floor of the defect its plasty has been carried out: in the basic group the defect has been filled with osteoconductive biomaterial, and in the comparison group — with polymethylmethacrylate to restore the anatomical configuration of condyles. Besides, before cement fixation of the prosthesis in the basic group the received autograft has been put on the restored implant plateau. Results: Assessing the results during the period from 2 to 4 years objective criteria have included the data of X-ray imaging, biomechanical research and WOMAC test. In the postoperative period significant differences have not been revealed. In the follow-up period in the group with application of the combined osteoplasty joint remodulation of autograft and osteoplastic biomaterial with regenerative restoration of bone tissue of the implant plateau has been observed. Conclusion: The described technique may reduce the relative risk of revision arthroplasty.

  6. Late rupture of the posterior cruciate ligament after total knee replacement.

    OpenAIRE

    Montgomery, R. L.; Goodman, S. B.; Csongradi, J.

    1993-01-01

    To our knowledge there have been no reports of late rupture of the posterior cruciate ligament (PCL) as a cause of instability in PCL-retaining total knee prostheses. In our experience of 150 total knee replacements using PCL-retaining prosthesis, three cases (2.0%) of late rupture of the posterior cruciate ligament have occurred, each leading to chronic instability, disabling pain, and revision arthroplasty. In each case rupture of the posterior cruciate ligament was confirmed at the time of...

  7. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender

    OpenAIRE

    Nassif, Jeffrey M.; Pietrzak, William S.

    2015-01-01

    While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based dif...

  8. Total knee arthroplasty using patient-specific blocks after prior femoral fracture without hardware removal

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2018-01-01

    Full Text Available Background: The options to perform total knee arthroplasty (TKA with retained hardware in femur are mainly – removal of hardware, use of extramedullary guide, or computer-assisted surgery. Patient-specific blocks (PSBs have been introduced with many potential advantages, but their use in retained hardware has not been adequately explored. The purpose of the present study was to outline and assess the usefulness of the PSBs in performing TKA in patients with retained femoral hardware. Materials and Materials and Methods: Nine patients with retained femoral hardware underwent TKA using PSBs. All the surgeries were performed by the same surgeon using same implants. Nine cases (7 males and 2 females out of total of 120 primary TKA had retained hardware. The average age of the patients was 60.55 years. The retained hardware were 6 patients with nails, 2 with plates and one patient had screws. Out of the nine cases, only one patient needed removal of a screw which was hindering placement of pin for the PSB. Results: All the patients had significant improvement in their Knee Society Score (KSS which improved from 47.0 to postoperative KSS of 86.77 (P < 0.00. The mechanical axis was significantly improved (P < 0.03 after surgery. No patient required blood transfusion and the average tourniquet time was 41 min. Conclusion: TKA using PSBs is useful and can be used in patients with retained hardware with good functional and radiological outcome.

  9. Lower Limbs Function and Pain Relationships after Unilateral Total Knee Arthroplasty

    Science.gov (United States)

    Tali, Maie; Maaroos, Jaak

    2010-01-01

    The aim of the study was to evaluate gait characteristics, lower limbs joint function, and pain relationships associated with knee osteoarthritis of female patients before and 3 months after total knee arthroplasty at an outpatient clinic rehabilitation department. Gait parameters were registered, the active range of lower extremity joints was…

  10. The Time Course of Knee Swelling Post Total Knee Arthroplasty and Its Associations with Quadriceps Strength and Gait Speed.

    Science.gov (United States)

    Pua, Yong-Hao

    2015-07-01

    This study examines the time course of knee swelling post total knee arthroplasty (TKA) and its associations with quadriceps strength and gait speed. Eighty-five patients with unilateral TKA participated. Preoperatively and on post-operative days (PODs) 1, 4, 14, and 90, knee swelling was measured using bioimpedance spectrometry. Preoperatively and on PODs 14 and 90, quadriceps strength was measured using isokinetic dynamometry while fast gait speed was measured using the timed 10-meter walk. On POD1, knee swelling increased ~35% from preoperative levels after which, knee swelling reduced but remained at ~11% above preoperative levels on POD90. In longitudinal, multivariable analyses, knee swelling was associated with quadriceps weakness (P<0.01) and slower gait speed (P=0.03). Interventions to reduce post-TKA knee swelling may be indicated to improve quadriceps strength and gait speed. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: An experimental cadaver study.

    Science.gov (United States)

    Scheele, Christian; Pietschmann, Matthias F; Schröder, Christian; Grupp, Thomas; Holderied, Melanie; Jansson, Volmar; Müller, Peter E

    2017-03-01

    Unicompartmental total knee arthroplasty (UKA) is a well-established treatment option for unicondylar osteoarthritis, and generally leads to better functional results than tricompartimental total knee arthroplasty (TKA). However, revision rates of UKAs are reported as being higher; a major reason for this is aseptic loosening of the tibial component due to implant-cement-bone interface fatigue. The objective of this study was to determine the effects of trabecular bone preparation, prior to implantation of tibial UKAs, on morphological and biomechanical outcomes in a cadaver study. Cemented UKAs were performed in 18 human cadaver knees after the bone bed was cleaned using pulsed lavage (Group A), conventional brush (Group B) or no cleaning at all (Group C, control). Morphologic cement penetration and primary stability were measured. The area proportion under the tibial component without visible cement penetration was significantly higher in Group C (21.9%, SD 11.9) than in both Group A (7.1%, SD 5.8), and Group B (6.5%, SD 4.2) (P=0.007). The overall cement penetration depth did not differ between groups. However, in the posterior part, cement penetration depth was significantly higher in Group B (1.9mm, SD 0.3) than in both Group A (1.3mm, SD 0.3) and Group C (1.4mm, SD 0.3) (P=0.015). The mode of preparation did not show a substantial effect on primary stability tested under dynamic compression-shear test conditions (P=0.910). Bone preparation significantly enhances cement interdigitation. The application of a brush shows similar results compared with the application of pulsed lavage. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. The constraints on day-case total knee arthroplasty

    DEFF Research Database (Denmark)

    Thienpont, E; Lavand'homme, P; Kehlet, H

    2015-01-01

    Total knee arthroplasty (TKA) is a major orthopaedic intervention. The length of a patient's stay has been progressively reduced with the introduction of enhanced recovery protocols: day-case surgery has become the ultimate challenge. This narrative review shows the potential limitations of day...

  13. Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score: A multivariable regression analysis.

    Science.gov (United States)

    Huijbregts, Henricus J T A M; Khan, Riaz J K; Fick, Daniel P; Jarrett, Olivia M; Haebich, Samantha

    2016-06-01

    Approximately 18% of the patients are dissatisfied with the result of total knee replacement. However, the relation between dissatisfaction and prosthetic alignment has not been investigated before. We retrospectively analysed prospectively gathered data of all patients who had a primary TKR, preoperative and one-year postoperative Oxford Knee Scores (OKS) and postoperative computed tomography (CT). The CT protocol measures hip-knee-ankle (HKA) angle, and coronal, sagittal and axial component alignment. Satisfaction was defined using a five-item Likert scale. We dichotomised dissatisfaction by combining '(very) dissatisfied' and 'neutral/not sure'. Associations with dissatisfaction and change in OKS were calculated using multivariable logistic and linear regression models. 230 TKRs were implanted in 105 men and 106 women. At one year, 12% were (very) dissatisfied and 10% neutral. Coronal alignment of the femoral component was 0.5 degrees more accurate in patients who were satisfied at one year. The other alignment measurements were not different between satisfied and dissatisfied patients. All radiographic measurements had a P-value>0.10 on univariate analyses. At one year, dissatisfaction was associated with the three-months OKS. Change in OKS was associated with three-months OKS, preoperative physical SF-12, preoperative pain and cruciate retaining design. Neither mechanical axis, nor component alignment, is associated with dissatisfaction at one year following TKR. Patients get the best outcome when pain reduction and function improvement are optimal during the first three months and when the indication to embark on surgery is based on physical limitations rather than on a high pain score. 2. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    Science.gov (United States)

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Preoperative diagnostic for periprosthetic joint infection prior to total knee revision arthroplasty

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2014-08-01

    Full Text Available Periprosthetic joint infection (PJI after total knee arthroplasty remains a challenging problem. The aim of this study was to evaluate the accuracy of diagnostic knee aspiration and serum inflammatory markers in diagnostic of a PJI after total knee arthroplasty. Within 2011 and 2012, 46 patients received a one- or two-stage revision arthroplasty of the knee joint. These patients received a total number of 77 operations. A preoperative aspiration was performed in each case. We analyzed the microbiological and histological examinations of the samples from the aspiration and from the revision operation and additionally estimated serum inflammatory markers. The diagnostic aspiration had a specificity of 0.87, a sensitivity of 0.39, a positive predictive value of 0.67 and a negative predictive value of 0.68. For C-reactive protein the specificity was 0.61 and the sensitivity was 0.48, the serum white blood cell count had a specificity of 0.98 and a sensitivity of 0.23. Our data queries whether diagnostic joint aspiration or serum inflammatory markers are sufficient to verify or exclude a PJI.

  16. Fast-track surgery for bilateral total knee replacement

    DEFF Research Database (Denmark)

    Husted, H; Troelsen, A; Otte, K S

    2011-01-01

    Bilateral simultaneous total knee replacement (TKR) has been considered by some to be associated with increased morbidity and mortality. Our study analysed the outcome of 150 consecutive, but selected, bilateral simultaneous TKRs and compared them with that of 271 unilateral TKRs in a standardised...

  17. Changing trends in total knee replacement

    OpenAIRE

    Goudie, Ewan; Robinson, Cal; Walmsley, Phil; Brenkel, Ivan

    2017-01-01

    Introduction:  This study evaluates a possible change in the demographics and surgical practice observed in a large cohort of patients undergoing total knee replacement (TKR). Patients and methods:  We performed a retrospective analysis of a prospectively collected data on two groups of consecutive patients undergoing primary TKR. Group one consisted of patients who underwent surgery between 1994 and 1998. Group two consisted of patients who had surgery between 2009 and 2012. Results:  The me...

  18. Midflexion instability in primary total knee replacement: a review

    Directory of Open Access Journals (Sweden)

    Ramappa Manjunath

    2015-01-01

    Full Text Available Introduction: Midflexion instability in primary total knee replacement (TKR is an evolving concept. Successful treatment of instability requires an understanding of the different types of instability. Methods: A literature review was performed to identify information pertinent to midflexion instability in primary total knee replacement, utilising PRISMA guidelines. Databases searched included Embase, Medline, All of the Cochrane Library, PubMed and cross references. Results: Three factors, i.e., elevated joint line, multiradii femoral component and medial collateral ligament (MCL laxity, were identified to influence midflexion instability. Literature suggested mediolateral instability at 30–60° of flexion as diagnostic of midflexion instability. Literature search also revealed paucity in clinical studies analysing midflexion instability. Most of the evidence was obtained from cadaveric studies for elevated joint line and MCL laxity. Clinical studies on multiradii femoral component were limited by their small study size and early followup period. Conclusion: Elevated joint line, multiradii femoral component and MCL laxity have been suggested to cause midflexion laxity in primary TKR. Due to limitations in available evidence, this review was unable to raise the strength of overall evidence. Future well-designed clinical studies are essential to make definitive conclusions. This review serves as a baseline for future researchers and creates awareness for routine assessment of midflexion instability in primary total knee replacement.

  19. Intra- and inter-rater reliability of the Knee Society Knee Score when used by two physiotherapists in patients post total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    S. Gopal

    2010-01-01

    Full Text Available Background and Purpose: It has yet to be shown whether routine physiotherapy plays a role in the rehabilitation of patients post totalknee arthroplasty (Rajan et al 2004. Physiotherapists should be using validoutcome measures to provide evidence of the benefit of their intervention. The aim of this study was to establish the intra and inter-rater reliability of the Knee Society Knee Score, a scoring system developed by Insall et al(1989. The Knee Society Knee Score can be used to assess the integrity of theknee joint of patients undergoing total knee arthroplasty. Since the scoreinvolves clinical testing, the intra-rater reliability of the clinician should be established prior to using the scores as datain clinical research. W here multiple clinicians are involved, inter-rater reliability should also be established.Design: This was a correlation study.Subjects: A  sample of thirty patients post total knee arthroplasty attending the arthroplasty clinic at Johannesburg Hospital between six weeks and twelve months postoperatively.M ethod: Recruited patients were evaluated twice with a time interval of one hour between each assessment. Statistical A nalysis: The intra- and inter-rater reliability were estimated using Intraclass Correlation Coefficient (ICC. R esults: The intra-rater reliability showed excellent reliability (h= 0.95 for Examiner A  and good reliability (h= 0.71for Examiner B. The inter-rater reliability showed moderate reliability (h= 0.67 during test one and h= 0.66 during test two.Conclusion: The KSKS has good intra-rater reliability when tested within a period of one hour. The KSKS demonstrated moderate agreement for inter rater reliability.

  20. Evaluation of gait performance of knee osteoarthritis patients after total knee arthroplasty with different assistive devices

    OpenAIRE

    Tereso,Ana; Martins,Maria Manuel; Santos,Cristina Peixoto

    2015-01-01

    IntroductionNowadays Knee Osteoarthritis (KOA) affects a large percentage of the elderly, and one solution is to perform a Total Knee Arthroplasty (TKA). In this paper, one intends to study the gait and posture of these patients after the TKA, while walking with three assistive devices (ADs) (crutches, standard walker (SW) and rollator with forearm supports (RFS)).MethodsEleven patients were evaluated in 2 phases: 5 days and 15 days after surgery. This evaluation was conducted with two inerti...

  1. Posterior tibial slope impacts intraoperatively measured mid-flexion anteroposterior kinematics during cruciate-retaining total knee arthroplasty.

    Science.gov (United States)

    Dai, Yifei; Cross, Michael B; Angibaud, Laurent D; Hamad, Cyril; Jung, Amaury; Jenny, Jean-Yves

    2018-02-23

    Posterior tibial slope (PTS) for cruciate-retaining (CR) total knee arthroplasty (TKA) is usually pre-determined by the surgeon. Limited information is available comparing different choices of PTS on the kinematics of the CR TKA, independent of the balancing of the extension gap. This study hypothesized that with the same balanced extension gap, the choice of PTS significantly impacts the intraoperatively measured kinematics of CR TKA. Navigated CR TKAs were performed on seven fresh-frozen cadavers with healthy knees and intact posterior cruciate ligament (PCL). A custom designed tibial baseplate was implanted to allow in situ modification of the PTS, which altered the flexion gap but maintained the extension gap. Knee kinematics were measured by performing passive range of motion (ROM) tests from full extension to 120° of flexion on the intact knee and CR TKAs with four different PTSs (1°, 4°, 7°, and 10°). The measured kinematics were compared across test conditions to assess the impact of PTS. With a consistent extension gap, the change of PTS had significant impact on the anteroposterior (AP) kinematics of the CR TKA knees in mid-flexion range (45°-90°), but not so much for the high-flexion range (90°-120°). No considerable impacts were found on internal/external (I/E) rotation and hip-knee-ankle (HKA) angle. However, the findings on the individual basis suggested the impact of PTS on I/E rotation and HKA angle may be patient-specific. The data suggested that the choice of PTS had the greatest impact on the mid-flexion AP translation among the intraoperatively measured kinematics. This impact may be considered while making surgical decisions in the context of AP kinematics. When using a tibial component designed with "center" pivoting PTS, a surgeon may be able to fine tune the PTS to achieve proper mid-flexion AP stability.

  2. Factors affecting wound ooze in total knee replacement

    Science.gov (United States)

    Butt, U; Ahmad, R; Aspros, D; Bannister, GC

    2010-01-01

    INTRODUCTION Wound ooze is common following total knee arthroplasty (TKA) and persistent wound infection is a risk factor for infection, and increased length and cost of hospitalisation. PATIENTS AND METHODS We undertook a prospective study to assess the effect of tourniquet time, peri-articular local anaesthesia and surgical approach on wound oozing after TKA. RESULTS The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Peri-articular local anaesthesia (0.25% Bupivacaine with 1:1,000,000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 min (range, 38–125 min). We found a significant association between cessation of oozing and peri-articular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). CONCLUSIONS Peri-articular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty. PMID:20836920

  3. Kinematic and kinetic analysis of the knee joint before and after a PCL retaining total knee replacement during gait and single step ascent.

    Science.gov (United States)

    Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos

    2011-01-01

    The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.

  4. Unilateral vs one stage bilateral total knee replacement in rheumatoid and osteoarthritis - A comparative study

    Directory of Open Access Journals (Sweden)

    Kiran E

    2005-01-01

    Full Text Available Background : A controversy exists regarding simultaneous or staged bilateral total knee replacement. Methods: Fifty patients undergoing simultaneous bilateral and 50 undergoing unilateral total knee arthroplasty were evaluated prospectively to compare the clinical, radiological results and complication rates. Eighty-four patients belonged to ASA category II or III preoperatively. The study included a high proportion of rheumatoid patients and osteoarthritis patients with severe deformities. Results: Bilateral group had greater blood loss and required more blood transfusion, but there was no difference in requirement of postoperative intensive care and the complication rates. Rheumatoid knees had lower pre and postoperative knee score and functional score as compared to osteoarthritic knees. Morbidity and mortality of one stage bilateral knee replacement was no greater than unilateral operation. Conclusion: Simultaneous bilateral knee replacement in younger patients with advanced rheumatoid arthritis is safe and effective

  5. Tibiofemoral contact stress and stress distribution evaluation of total knee arthroplasties.

    Science.gov (United States)

    Szivek, J A; Cutignola, L; Volz, R G

    1995-08-01

    The Fuji film (Itochu, Los Angeles, CA) area analysis technique demonstrates that a more accurate assessment of tibiofemoral contact stresses is possible when the film is used at 37 degrees C and at the upper end of its sensitivity range (in this case, a 2,000-N load). An AMK with a regular and Hylamer-M insert (DePuy, Warsaw, IN), an MG II (Zimmer, Warsaw, IN), an Omnifit (Osteonics, Allendale, NJ), an Ortholoc III (Dow Corning Wright, Midland, MI), a PCA II (Howmedica, Rutherford, NJ), and a PFC (Johnson & Johnson Orthopaedics, Raynham, MA) had average contact stresses that varied only 12% at 60 degrees flexion. At 0 degrees, 15 degrees and 60 degrees flexion, stresses ranged from 13 to 25 MPa. Contact area distribution ratios, which were smaller at 37 degrees C than at 24 degrees C, provide a quantitative means of grouping implants according to the shape of the tibiofemoral contact area. The Omnifit, MG II, PCA II, and PFC had small ratios (symmetric areas). The AMK and Ortholoc III had large ratios (asymmetric contact areas). If the impression is reflective of wear, it would be expected to be focal in knees with small ratios and contact areas, and uniform in knees with large ratios and contact areas, whereas large ratios and small areas would imply a linear wear pattern. Calibrated electrical resistance contact stress measurements indicated that the Fuji film measurements underestimated the magnitude of contact stresses. They also provided a means of quantifying the rate of area increase during initial loading of the knees, with the highest area increase noted for the knee with the roughest insert (Ortholoc III) and the lowest area increase for the knee with the smoothest insert (PCA II).

  6. Rivaroxaban versus enoxaparin for thromboprophylaxis after total knee arthroplasty (RECORD4): a randomised trial

    DEFF Research Database (Denmark)

    Turpie, Alexander G G; Lassen, Michael R; Davidson, Bruce L

    2009-01-01

    BACKGROUND: Prophylaxis for venous thromboembolism is recommended for at least 10 days after total knee arthroplasty; oral regimens could enable shorter hospital stays. We aimed to test the efficacy and safety of oral rivaroxaban for the prevention of venous thromboembolism after total knee arthr...

  7. Preoperative predictors of returning to work following primary total knee arthroplasty.

    Science.gov (United States)

    Styron, Joseph F; Barsoum, Wael K; Smyth, Kathleen A; Singer, Mendel E

    2011-01-05

    There is little in the literature to guide clinicians in advising patients regarding their return to work following a primary total knee arthroplasty. In this study, we aimed to identify which factors are important in estimating a patient's time to return to work following primary total knee arthroplasty, how long patients can anticipate being off from work, and the types of jobs to which patients are able to return following primary total knee arthroplasty. A prospective cohort study was performed in which patients scheduled for a primary total knee arthroplasty completed a validated questionnaire preoperatively and at four to six weeks, three months, and six months postoperatively. The questionnaire assessed the patient's occupational physical demands, ability to perform job responsibilities, physical status, and motivation to return to work as well as factors that may impact his or her recovery and other workplace characteristics. Two survival analysis models were constructed to evaluate the time to return to work either at least part-time or full-time. Acceleration factors were calculated to indicate the relative percentage of time until the patient returned to work. The median time to return to work was 8.9 weeks. Patients who reported a sense of urgency about returning to work were found to return in half the time taken by other employees (acceleration factor = 0.468; p mental health scores (acceleration factor = 0.891), higher physical function scores (acceleration factor = 0.809), higher Functional Comorbidity Index scores (acceleration factor = 0.914), and a handicap accessible workplace (acceleration factor = 0.736). A slower return to work was associated with having less pain preoperatively (acceleration factor = 1.132), having a more physically demanding job (acceleration factor = 1.116), and receiving Workers' Compensation (acceleration factor = 4.360). Although the physical demands of a patient's job have a moderate influence on the patient's ability

  8. No exacerbation of knee joint pain and effusion following preoperative progressive resistance training in patients scheduled for total knee arthroplasty

    DEFF Research Database (Denmark)

    Skoffer, Birgit; Dalgas, Ulrik; Maribo, Thomas

    2017-01-01

    BACKGROUND: Preoperative progressive resistance training (PRT) is controversial in patients scheduled for total knee arthroplasty (TKA), because of the concern that it may exacerbate knee joint pain and effusion. OBJECTIVE: To examine if preoperative PRT initiated 5 weeks prior to TKA would 1......) exacerbate pain and knee effusion, 2) allow a progressively increased training load throughout the training period that would subsequently increase muscle strength. DESIGN: Secondary analyses from a randomized controlled trial. SETTING: University Hospital and a Regional Hospital. PATIENTS: Thirty patients...... OUTCOME MEASURES: Before and after each training session, knee joint pain rated on an 11-point scale, effusion assessed by measuring the knee joint circumference, and training load were recorded. The first and last training session were initiated by 1RM testing of unilateral leg press, knee extension...

  9. Prevention of venous thromboembolic disease after total hip and knee arthroplasty.

    Science.gov (United States)

    Lieberman, Jay R; Hsu, Wellington K

    2005-09-01

    Patients undergoing total hip and knee arthroplasty are at increased risk for the development of venous thromboembolic disease, and there is general agreement that these patients require prophylaxis. The selection of a prophylactic agent involves a balance between efficacy and safety and often needs to be individualized for specific patients and institutions. Despite extensive research, the ideal agent for prophylaxis against deep venous thrombosis has not been identified. The results of randomized trials indicate that low-molecular-weight heparin, warfarin, and fondaparinux are the most effective prophylactic agents after total hip arthroplasty and that low-molecular-weight heparin, warfarin, fondaparinux, and pneumatic compression boots are the most effective agents after total knee arthroplasty. The duration of prophylaxis against deep venous thrombosis after total hip and knee arthroplasty remains controversial. Prophylaxis should be continued beyond hospital discharge. In the future, the determination of the duration of prophylaxis will be based on the risk stratification of individual patients. The practice of discharging patients from the hospital without prophylaxis, even when the decision is based on negative results of procedures that screen for the presence of deep venous thrombosis, is not cost-effective.

  10. Biomechanical Considerations in the Design of High-Flexion Total Knee Replacements

    Directory of Open Access Journals (Sweden)

    Cheng-Kung Cheng

    2014-01-01

    Full Text Available Typically, joint arthroplasty is performed to relieve pain and improve functionality in a diseased or damaged joint. Total knee arthroplasty (TKA involves replacing the entire knee joint, both femoral and tibial surfaces, with anatomically shaped artificial components in the hope of regaining normal joint function and permitting a full range of knee flexion. In spite of the design of the prosthesis itself, the degree of flexion attainable following TKA depends on a variety of factors, such as the joint’s preoperative condition/flexion, muscle strength, and surgical technique. High-flexion knee prostheses have been developed to accommodate movements that require greater flexion than typically achievable with conventional TKA; such high flexion is especially prevalent in Asian cultures. Recently, computational techniques have been widely used for evaluating the functionality of knee prostheses and for improving biomechanical performance. To offer a better understanding of the development and evaluation techniques currently available, this paper aims to review some of the latest trends in the simulation of high-flexion knee prostheses.

  11. [Surgical technique and clinical results of total knee arthroplasty in treating endstage gonarthrosis combined with valgus knee deformity].

    Science.gov (United States)

    Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei

    2012-05-01

    To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6

  12. Selective peripheral nerve resection for treatment of persistent pain around the knee joint after total knee arthroplasty.

    Science.gov (United States)

    Zhong, Guangjun; Liang, Zhu; Kan, Jiang; Muheremu, Aikeremujiang

    2018-01-01

    Objective This study was performed to determine the efficacy of selective peripheral nerve resection for treatment of persistent neuropathic pain after total knee arthroplasty (TKA). Methods Patients who underwent TKA in our department from January 2013 to July 2016 and experienced persistent pain around the knee joint after TKA were retrospectively included in the current study. Sixty patients were divided into experimental and control groups according the treatment they received. The treatment effect was evaluated by the Hospital for Special Surgery (HSS) knee score and visual analog scale (VAS) pain score preoperatively and at 1, 2, 3, 6, and 12 months postoperatively. Results The HSS knee scores were higher in both groups after than before the treatment, and HSS knee scores were significantly higher in the experimental group than in the control group. The VAS pain scores were lower in both groups after than before the treatment, and VAS pain scores were significantly lower in the experimental group than in the control group. Conclusions Selective peripheral nerve resection is an effective treatment method for persistent neuropathic pain after TKA.

  13. Alpine Skiing With total knee ArthroPlasty (ASWAP)

    DEFF Research Database (Denmark)

    Kristensen, M.; Pötzelsberger, B.; Scheiber, P.

    2015-01-01

    We investigated the effect of alpine skiing for 12 weeks on skeletal muscle characteristics and biomarkers of glucose homeostasis and cardiovascular risk factors. Twenty-three patients with a total knee arthroplasty (TKA) were studied 2.9 ± 0.9 years (mean ± SD) after the operation. Fourteen...

  14. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing

    2013-12-01

    To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.

  15. Influences of continuous femoral nerve block on knee function and quality of life in patients following total knee arthroplasty.

    Science.gov (United States)

    Wang, Fen; Zhou, Yingjie; Sun, Jiajun; Yang, Chunxi

    2015-01-01

    Continuous femoral nerve block (CFNB), guided by ultrasound combined nerve stimulations, offers advantages for both sides and provides effective postoperative analgesia after total knee arthroplasty (TKA). The objective of this study was to evaluate the medium-term impact of continuous femoral nerve block on knee function and quality of life in patients following TKA. This was a follow-up study. Total 168 adult patients scheduled for elective TKA were randomly allocated to receive postoperative continuous femoral nerve block guided by ultrasound combined nerve stimulator (group CFNB, n = 82) or patient-controlled epidural analgesia (group PCEA, n = 86). Quality of life, knee function, patient satisfaction, pain medication and associated adverse effects were compared at 1, 3, 6, and 12 months postoperatively. Quality of life was assessed using the Medical Outcomes Study Short Form-36 Health Survey (MOS SF-36), and clinical results were assessed using the Hospital for Special Surgery (HSS) Knee Scoring System. Patient satisfaction scores were divided into four categories. A total of 162 patients completed the 12-month follow-up. The CFNB group patients had significantly improved SF-36 scores and physical function at 1 month postoperatively (P quality of life in patients at one month postoperatively. Continuous femoral nerve block is a good choice for postoperative analgesia after TKA.

  16. Subchondral chitosan/blood implant-guided bone plate resorption and woven bone repair is coupled to hyaline cartilage regeneration from microdrill holes in aged rabbit knees.

    Science.gov (United States)

    Guzmán-Morales, J; Lafantaisie-Favreau, C-H; Chen, G; Hoemann, C D

    2014-02-01

    Little is known of how to routinely elicit hyaline cartilage repair tissue in middle-aged patients. We tested the hypothesis that in skeletally aged rabbit knees, microdrill holes can be stimulated to remodel the bone plate and induce a more integrated, voluminous and hyaline cartilage repair tissue when treated by subchondral chitosan/blood implants. New Zealand White rabbits (13 or 32 months old, N = 7) received two 1.5 mm diameter, 2 mm depth drill holes in each knee, either left to bleed as surgical controls or press-fit with a 10 kDa (distal hole: 10K) or 40 kDa (proximal hole: 40K) chitosan/blood implant with fluorescent chitosan tracer. Post-operative knee effusion was documented. Repair tissues at day 0 (N = 1) and day 70 post-surgery (N = 6) were analyzed by micro-computed tomography, and by histological scoring and histomorphometry (SafO, Col-2, and Col-1) at day 70. All chitosan implants were completely cleared after 70 days, without increasing transient post-operative knee effusion compared to controls. Proximal control holes had worse osteochondral repair than distal holes. Both implant formulations induced bone remodeling and improved lateral integration of the bone plate at the hole edge. The 40K implant inhibited further bone repair inside 50% of the proximal holes, while the 10K implant specifically induced a "wound bloom" reaction, characterized by decreased bone plate density in a limited zone beyond the initial hole edge, and increased woven bone (WB) plate repair inside the initial hole (P = 0.016), which was accompanied by a more voluminous and hyaline cartilage repair (P holes with a biodegradable subchondral implant that elicits bone plate resorption followed by anabolic WB repair within a 70-day repair period. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  17. Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Kobayashi Hideo

    2012-10-01

    Full Text Available Abstract Background The mobile bearing knee system was introduced to lessen contact stress on the articular bearing surface and reduce polyethylene wear. The purpose of the current study was to investigate the mid-term results of patients undergoing total knee arthroplasties (TKAs using Scorpio Plus Mobile Bearing Knee System (Stryker, Mahwah, NJ, and compare the outcomes between patients with osteoarthritis and osteonecrosis (OA·ON group and patients with rheumatoid arthritis (RA group. Methods Eight males and 58 females were followed up for a period of 4.4- 7.6 years from June 1, 2003 to December 31, 2005. There were 53 knees with osteoarthritis, 17 knees with rheumatoid arthritis, and 6 knees with osteonecrosis. Clinical and radiographic follow- up was done using The Japanese Orthopedic Association knee rating score (JOA score and Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Results With regard to the JOA score, there was significant improvement in both groups. The postoperative range of motion was between 0.8°and 116.8° in OA·ON group, and between 0.0° and 113.7° in RA group. There were no significant differences with the radiographic evaluation between two groups. Spontaneous dislocation of a polyethylene insert occurred in one patient, and deep infection was occurred in one patient. Conclusion There was significant improvement with regard to the clinical and radiographic results of patients undergoing TKAs using the model. The risk of polyethylene insert dislocation related to the mobile bearing TKA is a cause for concern.

  18. Total Artificial Heart Implantation Blood Pressure Management as Resolving Treatment for Massive Hemolysis following Total Artificial Heart Implantation.

    Science.gov (United States)

    Ghodsizad, Ali; Koerner, Michael M; El-Banayosy, A; Zeriouh, Mohamed; Ruhparwar, Arjang; Loebe, Matthias

    2016-10-21

    The SynCardia Total Artificial Heart (TAH) has been used for patients with biventricular failure, who cannot be managed with implantation of a left ventricular (LV) assist device. Following TAH implantation, our patient developed severe hemolysis, which could only be managed successfully by aggressive blood pressure control [Ohashi 2003; Nakata 1998].

  19. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    Science.gov (United States)

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (Pnew implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  20. Atraumatic patellar prosthesis dislocation with patellar tendon injury following a total knee arthroplasty: a case report

    Directory of Open Access Journals (Sweden)

    Singh Alka

    2010-01-01

    Full Text Available Abstract Introduction Total knee arthroplasty is a well-established procedure with gratifying results. There is no consensus in the literature whether to routinely resurface the patella while performing total knee arthroplasty or not. Although an extremely rare occurrence in clinical practice, patellar prosthesis dislocation is a possible complication resulting from total knee arthroplasty. Case presentation We report a rare case of atraumatic spontaneous dislocation of patellar prosthesis in a 63-year-old Caucasian man of British origin with patellar tendon injury. The patient was treated successfully through a revision of the patellar component and tendon repair. In two years follow-up the patient is asymptomatic with no sign of loosening of his patellar prosthesis. Conclusions A thorough understanding of knee biomechanics is imperative in performing total knee arthroplasty in order to achieve a better functional outcome and to prevent early prosthetic failure.

  1. Compartment syndrome after total knee arthroplasty: regarding a clinical case

    Directory of Open Access Journals (Sweden)

    Ana Alexandra da Costa Pinheiro

    2015-08-01

    Full Text Available ABSTRACT Although compartment syndrome is a rare complication of total knee arthroplasty, it is one of the most devastating complications. It is defined as a situation of increased pressure within a closed osteofascial space that impairs the circulation and the functioning of the tissues inside this space, thereby leading to ischemia and tissue dysfunction. Here, a clinical case of a patient who was followed up in orthopedic outpatient consultations due to right gonarthrosis is presented. The patient had a history of arthroscopic meniscectomy and presented knee flexion of 10° before the operation, which consisted of total arthroplasty of the right knee. The operation seemed to be free from intercurrences, but the patient evolved with compartment syndrome of the ipsilateral leg after the operation. Since compartment syndrome is a true surgical emergency, early recognition and treatment of this condition through fasciotomy is crucial in order to avoid amputation, limb dysfunction, kidney failure and death. However, it may be difficult to make the diagnosis and cases may not be recognized if the cause of compartment syndrome is unusual or if the patient is under epidural analgesia and/or peripheral nerve block, which thus camouflages the main warning sign, i.e. disproportional pain. In addition, edema of the limb that underwent the intervention is common after total knee arthroplasty operations. This study presents a review of the literature and signals that the possible rarity of cases is probably due to failure to recognize this condition in a timely manner and to placing these patients in other diagnostic groups that are less likely, such as neuropraxia caused by using a tourniquet or peripheral nerve injury.

  2. Does patellofemoral congruence following total knee arthroplasty correlate with pain or function? Intraoperative arthroscopic assessment of 30 cases.

    Science.gov (United States)

    Senioris, Antoine; Saffarini, Mo; Rahali, Said; Malekpour, Louis; Dujardin, Franck; Courage, Olivier

    2016-08-01

    Anterior knee pain (AKP) is observed in total knee arthroplasty (TKA) both with and without patellar resurfacing, and neither patellar denervation nor secondary resurfacing are effective for treating the symptoms. The exact causes for pain remain unclear, though abnormal patellofemoral forces due to patellar malalignment or inadequate implant design can play an important role. The purpose of this study was to arthroscopically evaluate patellofemoral congruence after wound closure following TKA without patellar resurfacing and correlate it to patellar morphology and postoperative pain and function. The authors prospectively studied 30 patients that received uncemented mobile-bearing TKA. Patellofemoral congruence was assessed arthroscopically after wound closure by estimating the contact area between the native patella and the prosthetic trochlea (> two-thirds, > one-third, congruence was correlated with patellar morphology (Pcongruence and patient characteristics. While patellar morphology and patellofemoral congruence are strongly related, they are not associated with clinical outcomes or patient demographics. Considering that numerous incongruent patellofemoral joints were pain-free, and conversely, many perfectly congruent patellofemoral joints had anterior pain, the authors suppose that pain is probably caused by mechanisms other than patellofemoral pressures.

  3. Physical health problems experienced in the early postoperative recovery period following total knee replacement

    DEFF Research Database (Denmark)

    Szötz, Kirsten; Pedersen, Preben Ulrich; Hørdam, Britta

    2015-01-01

    of exercising in the early recovery period after discharge from hospital following total knee replacement. METHOD: A cross-sectional survey was conducted using a questionnaire. A total of 86 patients were included following first-time elective total knee replacement. Descriptive statistics were used. RESULTS......: The majority of the patients experienced leg oedema (90.7%). Secondary to this were pain (81.4%), sleeping disorders (47.7%) problems with appetite (38.4%) and bowel function (34.9%) were the most frequently identified physical health problems. In total, 69.8% of the patients indicated that they did...... not exercise or only partly exercise as recommended, but without associated experience of pain. CONCLUSION: Patients experienced a wide range of physical health problems following total knee replacement and deviation from recommended self-training was identified. These findings are valuable for health...

  4. Low manipulation prevalence following fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik; Jørgensen, Christoffer C.; Gromov, Kirill

    2015-01-01

    BACKGROUND AND PURPOSE: Postoperative joint stiffness following total knee arthroplasty (TKA) may compromise the outcome and necessitate manipulation. Previous studies have not been in a fast-track setting with optimized pain treatment, early mobilization, and short length of stay (LOS), which ma...

  5. Surface neuromuscular electrical stimulation for quadriceps strengthening pre and post total knee replacement.

    LENUS (Irish Health Repository)

    Monaghan, Brenda

    2010-01-01

    Total knee replacement has been demonstrated to be one of the most successful procedures in the treatment of osteoarthritis. However quadriceps weakness and reductions in function are commonly reported following surgery. Recently Neuromuscular Electrical Stimulation (NMES) has been used as an adjunct to traditional strengthening programmes. This review considers the effectiveness of NMES as a means of increasing quadriceps strength in patients before and after total knee replacement.

  6. Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury

    Science.gov (United States)

    Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan

    2009-01-01

    Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618

  7. Patient specific instrumentation in total knee arthroplasty: a state of the art

    Science.gov (United States)

    Mattei, Lorenzo; Pellegrino, Pietro; Bistolfi, Alessandro; Castoldi, Filippo

    2016-01-01

    Patient specific instrumentation (PSI) is a modern technique in total knee arthroplasty (TKA) aiming to facilitate the implant of the prosthesis. The customized cutting blocks of the PSI are generated from pre-operative three-dimensional model, using computed tomography (CT) or magnetic resonance imaging (MRI). A correct surgical plan is mandatory for a good surgical implant. The PSI guide takes into account any slight deformities or osteophytes and applies preoperative planning for bone resection, using the pre-determined implant size, position, and rotation. The apparent benefits of this technology are that neutral postoperative alignment is more reproducible, surgical time is decreased, and the entire procedure results more efficient and cost-effective. The use of PSI is indicated when advanced osteoarthritis, severe pain, and limited function/walking ability are present, such as in a standard instrumentation TKA. In addition to that, PSI finds its indication when intra-medullary guides cannot be used. For example, when there is a post-traumatic femoral deformity. Large debates have taken place about this topic during the last years and, at the moment, there is no consensus in literature regarding the accuracy and reliability of PSI as many studies have shown controversial and inconsistent results. Literature does not suggest PSI techniques as a gold standard in TKA, and therefore it cannot be recommended as a standard technique in standard, not complicated primary TKA. Moreover, literature does not underline any improvement in components alignment, surgical time, blood loss or functional outcomes. Nevertheless, many patients who underwent TKA suffered a previous trauma. In case of deformities, like femoral or tibial fractures healed with a malalignment, preoperative planning may result difficult, and some intra-operative technical difficulties can occur, such as the use of intra-medullar rod. In these selected cases, PSIs may be very useful to avoid errors in

  8. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  9. Criteria used when deciding on eligibility for total knee arthroplasty

    DEFF Research Database (Denmark)

    Skou, Søren Thorgaard; Ross, Ewa M.; Laursen, Mogens Berg

    2016-01-01

    BACKGROUND: Clinical decision-making in total knee arthroplasty (TKA) is a complex process needing further clarification. The aim of this study was to compare TKA eligibility criteria considered most important by orthopedic surgeons (OSs) to characteristics of patients with knee osteoarthritis (OA....... CONCLUSION: Radiographic severity and functional limitations were confirmed as drivers for TKA eligibility, while pain was not. Not responding to non-surgical treatment was not included in the decision-making, suggesting low uptake of clinical guidelines in clinical practice. This study highlights...

  10. Iodine-impregnated incision drape and bacterial recolonization in simulated total knee arthroplasty

    DEFF Research Database (Denmark)

    Milandt, Nikolaj; Nymark, Tine; Jørn Kolmos, Hans

    2016-01-01

    bacteria in the surgical field of an arthroplasty, and surgery in general, may increase the infection risk. We investigated whether IIID use increases bacterial recolonization compared to no drape use under conditions of simulated total knee arthroplasty (TKA). Methods - 20 patients scheduled for TKA were...... recruited. Each patient had 1 knee randomized for draping with IIID, while the contralateral knee was left bare. The patients thus served as their own control. The operating room conditions and perioperative procedures of a TKA were simulated. Cylinder samples were collected from the skin of each knee prior...... to disinfection, and again on 2 occasions after skin preparation-75 min apart. Quantities of bacteria were estimated using a spread plate technique under aerobic conditions. Results - We found similar quantities of bacteria on the intervention and control knees immediately after skin disinfection and after 75 min...

  11. Matrix-induced autologous chondrocyte implantation for the treatment of chondral defects of the knees in Chinese patients

    Directory of Open Access Journals (Sweden)

    Zhang ZW

    2014-12-01

    Full Text Available Zhongwen Zhang,1 Xin Zhong,2 Huiru Ji,1 Zibin Tang,1 Jianpeng Bai,1 Minmin Yao,1 Jianlei Hou,1 Minghao Zheng,3 David J Wood,3 Jiazhi Sun,4 Shu-Feng Zhou,4,5 Aibing Liu6 1Department of Orthopedics, General Hospital of Chinese People’s Armed Police Forces (CAPF, Beijing; 2Department of MRI Center, General Hospital of CAPF, Beijing, People’s Republic of China; 3Center for Orthopedic Research, School of Surgery and Pathology, University of Western Australia, Perth, Western Australia, Australia; 4Department of Pharmaceutical Sciences, College of Pharmacy, University of South Florida, Tampa, FL, USA; 5Guizhou Provincial Key Laboratory for Regenerative Medicine, Stem Cell and Tissue Engineering Research Center and Sino–US Joint Laboratory for Medical Sciences, Guiyang Medical University, Guiyang, Guizhou; 6Medical Research Center, General Hospital of Chinese People’s Armed Police Forces (CAPF, Beijing, People’s Republic of China Abstract: Articular cartilage injury is the most common type of damage seen in clinical orthopedic practice. The matrix-induced autologous chondrocyte implant (MACI was developed to repair articular cartilage with an advance on the autologous chondrocyte implant procedure. This study aimed to evaluate whether MACI is a safe and efficacious cartilage repair treatment for patients with knee cartilage lesions. The primary outcomes were the Knee Injury and Osteoarthritis Outcome Score (KOOS domains and magnetic resonance imaging (MRI results, compared between baseline and postoperative months 3, 6, 12, and 24. A total of 15 patients (20 knees, with an average age of 33.9 years, had a mean defect size of 4.01 cm2. By 6-month follow-up, KOOS results demonstrated significant improvements in symptoms and knee-related quality of life. MRI showed significant improvements in four individual graft scoring parameters at 24 months postoperatively. At 24 months, 90% of MACI grafts had filled completely and 10% had good

  12. Do modern total knee replacements offer better value for money? A health economic analysis.

    Science.gov (United States)

    Hamilton, David F; Clement, Nicholas D; Burnett, Richard; Patton, James T; Moran, Mathew; Howie, Colin R; Simpson, A H R W; Gaston, Paul

    2013-11-01

    Cost effectiveness is an increasingly important factor in today's healthcare environment, and selection of arthroplasty implant is not exempt from such concerns. Quality adjusted life years (QALYs) are the typical tool for this type of evaluation. Using this methodology, joint arthroplasty has been shown to be cost effective; however, studies directly comparing differing prostheses are lacking. Data was gathered in a single-centre prospective double-blind randomised controlled trial comparing the outcome of modern and traditional knee implants, using the Short Form 6 dimensional (SF-6D) score and quality adjusted life year (QALY) methodology. There was significant improvement in the SF-6D score for both groups at one year (p traditional design at one year (0.141 versus 0.143, p = 0.94). This difference resulted in the modern implant costing £298 less per QALY at one year. This study demonstrates that modern implant technology does not influence the cost-effectiveness of TKA using the SF-6D and QALY methodology. This type of analysis however assesses health status, and is not sensitive to joint specific function. Evolutionary design changes in implant technology are thus unlikely to influence QALY analysis following joint replacement, which has important implications for implant procurement.

  13. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait

    NARCIS (Netherlands)

    Ruiter, L. de; Janssen, D.W.; Briscoe, A.; Verdonschot, N.J.

    2017-01-01

    BACKGROUND: Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE

  14. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  15. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  16. [Comparison of in vivo characteristics of polyethylene wear particles produced by a metal and a ceramic femoral component in total knee replacement].

    Science.gov (United States)

    Veigl, D; Vavřík, P; Pokorný, D; Slouf, M; Pavlova, E; Landor, I

    2011-01-01

    The aim of the study was to evaluate in vivo and compare, in terms of the quality and number of ultra high-molecular polyethylene (UHMWPE) wear particles, total knee replacements of identical construction differing only in the material used for femoral component production, i.e., CoCrMo alloy or ZrO2 ceramics. Samples of peri-prosthetic granuloma tissue were collected in two patients with total knee replacement suffering from implant migration, who were matched in relevant characteristics. The primary knee replacement in Patient 1 with a CoCrMo femoral component was done 7.2 years and in Patient 2 with a ZrO2 implant 6.8 years before this assessment. The polyethylene wear-induced granuloma was analysed by the MORF method enabling us to assess the shape and size of wear debris and the IRc method for assessment of particle concentration. In the granuloma tissue samples of Patient 1, on the average, particles were 0.30 mm in size and their relative volume was 0.19. In the Patient 2 tissue samples, the average size of particles was 0.33 mm and their relative volume was 0.26. There was no significant difference in either particle morphology or their concentration in the granuloma tissue between the two patients. One of the options of how to reduce the production of polyethylene wear particles is to improve the tribological properties of contacting surfaces in total knee replacement by substituting a cobalt-chrome femoral component with a zirconia ceramic femoral component. The previous in vitro testing carried out with a mechanical simulator under conditions approaching real weight-bearing in the human body did show a nearly three-fold decrease in the number of UHMWPE wear particles in zirconia components. The evaluation of granuloma tissue induced by the activity of a real prosthetic joint for nearly seven years, however, did not reveal any great difference in either quality or quantity of polyethylene debris between the two replacements. The difference of surface

  17. Percutaneous implantation of peripheral blood mononuclear cells mobilized with granulocyte colony stimulating factor in osteoarthritis of the knee. First case reported in Cuba

    International Nuclear Information System (INIS)

    Baganet Cobas, Aymara Maria; Hernandez Ramirez, Porfirio; Fernandez Delgado, Norma

    2010-01-01

    The degenerative joint disease, also known as osteoarthrosis affects to 10% of elderlies aged 60. It is mainly characterized by pain in the involved joint, crepitation, morning stiff and a progressive limitation of movement of that joint leading to a partial or total wear of articular cartilage. The treatment of the knee osteoarthrosis is a great challenge. The recent advances in use of regenerative medicine suggest that adult stem cells could represent a promisor alternative in the treatment of this entity. In a female patient aged 61 presenting with knee osteoarthrosis authors placed a percutaneous implant of autologous mononuclear cells mobilized to peripheral blood by granulocyte colony-stimulating factor achieving a fast clinical and radiological improvement. This result suggests that the procedure used is a feasible, simple, safe and less expensive method for treatment of articular degenerative lesions

  18. Functional assessment of patients after total knee replacement

    Directory of Open Access Journals (Sweden)

    Matla Joanna

    2017-06-01

    Full Text Available Introduction: In the society of the 21st century, osteoarthritis is considered one of the primary causes of the occurrence of pain and disability. Arthroplasty is the treatment of choice for advanced degenerative changes. The aim of the study was to carry out a functional assessment of patients at early stages of rehabilitation after total knee replacement.

  19. AQUILA: assessment of quality in lower limb arthroplasty. An expert Delphi consensus for total knee and total hip arthroplasty.

    Science.gov (United States)

    Pijls, Bart G; Dekkers, Olaf M; Middeldorp, Saskia; Valstar, Edward R; van der Heide, Huub J L; Van der Linden-Van der Zwaag, Henrica M J; Nelissen, Rob G H H

    2011-07-22

    In the light of both the importance and large numbers of case series and cohort studies (observational studies) in orthopaedic literature, it is remarkable that there is currently no validated measurement tool to appraise their quality. A Delphi approach was used to develop a checklist for reporting quality, methodological quality and generalizability of case series and cohorts in total hip and total knee arthroplasty with a focus on aseptic loosening. A web-based Delphi was conducted consisting of two internal rounds and three external rounds in order to achieve expert consensus on items considered relevant for reporting quality, methodological quality and generalizability. The internal rounds were used to construct a master list. The first external round was completed by 44 experts, 35 of them completed the second external round and 33 of them completed the third external round. Consensus was reached on an 8-item reporting quality checklist, a 6-item methodological checklist and a 22-item generalizability checklist. Checklist for reporting quality, methodological quality and generalizability for case series and cohorts in total hip and total knee arthroplasty were successfully created through this Delphi. These checklists should improve the accuracy, completeness and quality of case series and cohorts regarding total hip and total knee arthroplasty.

  20. A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait

    NARCIS (Netherlands)

    de Ruiter, Lennert; Janssen, Dennis W.; Briscoe, Adam; Verdonschot, Nico

    2017-01-01

    Background Conventional total knee replacement designs show high success rates but in the long term, the stiff metal components may affect bone quality of the distal femur. In this study we introduce an all-polymer total knee replacement device containing a PEEK femoral component on an UHMWPE tibial

  1. Knee Pain during Strength Training Shortly following Fast-Track Total Knee Arthroplasty: A Cross-Sectional Study

    Science.gov (United States)

    Bandholm, Thomas; Thorborg, Kristian; Lunn, Troels Haxholdt; Kehlet, Henrik; Jakobsen, Thomas Linding

    2014-01-01

    Background Loading and contraction failure (muscular exhaustion) are strength training variables known to influence neural activation of the exercising muscle in healthy subjects, which may help reduce neural inhibition of the quadriceps muscle following total knee arthroplasty (TKA). It is unknown how these exercise variables influence knee pain after TKA. Objective To investigate the effect of loading and contraction failure on knee pain during strength training, shortly following TKA. Design Cross-sectional study. Setting Consecutive sample of patients from the Copenhagen area, Denmark, receiving a TKA, between November 2012 and April 2013. Participants Seventeen patients, no more than 3 weeks after their TKA. Main outcome measures: In a randomized order, the patients performed 1 set of 4 standardized knee extensions, using relative loads of 8, 14, and 20 repetition maximum (RM), and ended with 1 single set to contraction failure (14 RM load). The individual loadings (kilograms) were determined during a familiarization session >72 hours prior. The patients rated their knee pain during each repetition, using a numerical rating scale (0–10). Results Two patients were lost to follow up. Knee pain increased with increasing load (20 RM: 3.1±2.0 points, 14 RM: 3.5±1.8 points, 8 RM: 4.3±2.5 points, P = 0.006), and repetitions to contraction failure (10% failure: 3.2±1.9 points, 100% failure: 5.4±1.6 points, Pknee pain 60 seconds after the final repetition (2.7±2.4 points) was not different from that recorded before strength training (2.7±1.8 points, P = 0.88). Conclusion Both loading and repetitions performed to contraction failure during knee- extension strength-training, increased post-operative knee pain during strength training implemented shortly following TKA. However, only the increase in pain during repetitions to contraction failure exceeded that defined as clinically relevant, and was very short-lived. Trial Registration Clinical

  2. Total knee replacement for tricompartmental arthritis in a patient with a below-knee amputation after a previous closing wedge high tibial osteotomy

    Directory of Open Access Journals (Sweden)

    Mark A. Fleming, MBBCH, FC orth(SA, MMED

    2016-06-01

    Full Text Available This is a report of a 64-year-old man who had undergone a high tibial osteotomy (HTO 17 years ago of his right knee for medial compartment osteoarthritis; 5 days later, he received a below-knee amputation owing to a missed popliteal artery injury at the time of the HTO. We elected to perform a total knee replacement (TKR for progressive arthritis of the ipsilateral knee 17 years after the transtibial amputation. Although there is a plethora of literature regarding TKR in the contralateral knee of amputees, there is a paucity of data of TKR in the ipsilateral knee. Using medical search engines including Google Scholar and PubMed, we were only able to identify 4 case reports of TKR in the ipsilateral knee of below-knee amputees. This is the first description in the English literature that has the following rare pathology list: tricompartmental arthritis with a previous closing wedge HTO with a resultant truncated valgus tibia and short transtibial amputation.

  3. Clinical outcomes after cell-seeded autologous chondrocyte implantation of the knee: when can success or failure be predicted?

    Science.gov (United States)

    Pestka, Jan M; Bode, Gerrit; Salzmann, Gian; Steinwachs, Mathias; Schmal, Hagen; Südkamp, Norbert P; Niemeyer, Philipp

    2014-01-01

    Autologous chondrocyte implantation (ACI) has been associated with satisfying results. Still, it remains unclear when success or failure after ACI can be estimated. To evaluate the clinical outcomes of cell-seeded collagen matrix-supported ACI (ACI-Cs) for the treatment of cartilage defects of the knee at 36 months and to determine a time point after ACI-Cs at which success or failure can be estimated. Cohort study; Level of evidence, 3. A total of 80 patients with isolated full-thickness cartilage defects of the knee joint treated with ACI-Cs were prospectively assessed before surgery as well as postoperatively by use of the International Knee Documentation Committee (IKDC) score and Lysholm knee score. Preoperative IKDC and Lysholm scores increased from 49.6 and 59.5, respectively, to 79.1 and 83.5, respectively, at 36 months. Only half the patients (46.6%) with poor IKDC scores (ie, <70) at 6 months postoperatively showed continued poor or fair scores at 36 months' follow-up. The probability of poor scores at 36 months after surgery further increased to 0.61 and 0.81, respectively, when scores were persistent at 12 and 24 months. All 3 patients (100%) with good IKDC scores (ie, 81-90) at 6 months after surgery showed constant or even improved scores at 36 months' follow-up. Ninety-one percent of patients with good and excellent scores at 12 months and 83% of patients with good and excellent scores at 24 months (a total of 23 and 37 patients, respectively) were able to maintain these scores at 36 months' follow-up. Similar results were obtained for the Lysholm score. With regard to the improvements in functional outcomes after ACI-Cs at 36 months after surgery, the technique described here appears to lead to satisfying and stable clinical results. This study helps the treating physician to predict the likeliness of further clinical improvements or constant unsatisfactory results after ACI. In patients with good/excellent scores shortly after surgery

  4. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    Science.gov (United States)

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    Science.gov (United States)

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero

  6. The use of postoperative suction drainage in total knee arthroplasty: a systematic review.

    LENUS (Irish Health Repository)

    Quinn, Mark

    2014-07-16

    The purpose of this systematic review and meta-analysis of randomised controlled trials is to assess the effectiveness of no drainage when compared to drainage in total knee arthroplasty, in terms of recovery of knee flexion, reduction in swelling, length of hospital stay and haemoglobin levels following TKA.

  7. Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

    Science.gov (United States)

    Pawaskar, Aditya; Salunke, Abhijeet Ashok; Kekatpure, Aashay; Chen, Yongsheng; Nambi, G I; Tan, Junhao; Sonawane, Dhiraj; Pathak, Subodhkumar

    2017-09-01

    To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty. A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis. The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively. This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. Level I.

  8. No difference in anterior knee pain between a fixed and a mobile posterior stabilized total knee arthroplasty after 7.9 years

    NARCIS (Netherlands)

    Breugem, Stefan J. M.; van Ooij, Bas; Haverkamp, Daniël; Sierevelt, Inger N.; van Dijk, C. Niek

    2014-01-01

    The presence of anterior knee pain remains one of the major complaints following total knee arthroplasty (TKA). Since the introduction of the mobile TKA, many studies have been performed and only a few show a slight advantage for the mobile. In our short-term follow-up study, we found less anterior

  9. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    Science.gov (United States)

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift

  10. Relevance of infiltration analgesia in pain relief after total knee arthroplasty

    Science.gov (United States)

    Znojek-Tymborowska, Justyna; Kęska, Rafał; Paradowski, Przemysław T.; Witoński, Dariusz

    2013-01-01

    OBJECTIVE: The aim of the study was to assess the effect of different types of anesthesia on pain intensity in early postoperative period. PATIENTS AND METHODS: A total of 87 patients (77 women, 10 men) scheduled for total knee arthroplasty (TKA) were assigned to receive either subarachnoid anesthesia alone or in combination with local soft tissue anesthesia, local soft tissue anesthesia and femoral nerve block and pre-emptive infiltration together with local soft tissue anesthesia. We assessed the pain intensity, opioid consumption, knee joint mobility, and complications of surgery. RESULTS: Subjects with pre-emptive infiltration and local soft tissue anesthesia had lower pain intensity on the first postoperative day compared to those with soft tissue anesthesia and femoral nerve block (P=0.012, effect size 0.68). Subjects who received pre-emptive infiltration and local soft-tissue anesthesia had the greatest range of motion in the operated knee at discharge (mean 90 grades [SD 7], P=0.01 compared to those who received subarachnoid anesthesia alone, and P=0.001 compared to those with subarachnoid together with soft tissue anesthesia). CONCLUSION: Despite the differences in postoperative pain and knee mobility, the results obtained throughout the postoperative period do not enable us to favour neither local nor regional infiltration anesthesia in TKA. Level of Evidence II, Prospective Comparative Study. PMID:24453679

  11. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  12. Total knee arthroplasty in patients with dialysis: Early complications and mortality

    Directory of Open Access Journals (Sweden)

    Jen-Hung Chen

    2014-04-01

    Full Text Available Background: Total hip arthroplasty (THA in patients on long-term hemodialysis may result in a high prevalence of complications which related to nature of the disease, and associated cardiovascular conditions. However, the result of total knee artrhopalsty (TKA in those patients is not clear. The purpose of this study was to retrospectively evaluate the early mortality and complications of TKA performed in patients with dialysis. Methods: We retrospectively evaluated 15 dialysis patients (18 knees who underwent TKA using antibiotic-loaded cement fixation. Fourteen patients had maintained hemodialysis and one patient had continuous ambulatory peritoneal dialysis. The function of the knee was evaluated before operation and postoperatively using Knee Society evaluating system. Postoperative complications and mortality were recorded for all patients. The average follow up period was 25 months (6 to 59 months. Results: There were no mortalities including short-term (≤90 days or long-term (>90 days follow up. The mean knee and function scores improved from preoperative 36 points (27~46 and 19.4 points (10~35 to 79 points (68~87 and 81 points (70~95 respectively at the latest follow up. One (6.7% patient had early postoperative pneumonia (≤90 days. The late (>90 days complica-tion rate was 20% including 1 sepsis with toe gangrene, 1 recurrent stroke and 1 acute myocardiac infarction. There was no deep prosthetic joint infection or loosening of the components. Conclusion: TKA with antibiotic-loaded cement resulted in a substantial low short-term mortality and deep infections in 15 patients with dialysis. However, a longer term follow up is necessary.

  13. An in vitro analysis of medial structures and a medial soft tissue reconstruction in a constrained condylar total knee arthroplasty.

    Science.gov (United States)

    Athwal, Kiron K; El Daou, Hadi; Inderhaug, Eivind; Manning, William; Davies, Andrew J; Deehan, David J; Amis, Andrew A

    2017-08-01

    The aim of this study was to quantify the medial soft tissue contributions to stability following constrained condylar (CC) total knee arthroplasty (TKA) and determine whether a medial reconstruction could restore stability to a soft tissue-deficient, CC-TKA knee. Eight cadaveric knees were mounted in a robotic system and tested at 0°, 30°, 60°, and 90° of flexion with ±50 N anterior-posterior force, ±8 Nm varus-valgus, and ±5 Nm internal-external torque. The deep and superficial medial collateral ligaments (dMCL, sMCL) and posteromedial capsule (PMC) were transected and their relative contributions to stabilising the applied loads were quantified. After complete medial soft tissue transection, a reconstruction using a semitendinosus tendon graft was performed, and the effect on kinematic behaviour under equivocal conditions was measured. In the CC-TKA knee, the sMCL was the major medial restraint in anterior drawer, internal-external, and valgus rotation. No significant differences were found between the rotational laxities of the reconstructed knee to the pre-deficient state for the arc of motion examined. The relative contribution of the reconstruction was higher in valgus rotation at 60° than the sMCL; otherwise, the contribution of the reconstruction was similar to that of the sMCL. There is contention whether a CC-TKA can function with medial deficiency or more constraint is required. This work has shown that a CC-TKA may not provide enough stability with an absent sMCL. However, in such cases, combining the CC-TKA with a medial soft tissue reconstruction may be considered as an alternative to a hinged implant.

  14. Highly Cross-Linked Polyethylene in Total Hip and Knee Replacement: Spatial Distribution of Molecular Orientation and Shape Recovery Behavior

    Directory of Open Access Journals (Sweden)

    Yasuhito Takahashi

    2014-01-01

    Full Text Available The present study investigated effects of processing procedures on morphology of highly cross-linked and re-melted UHMWPE (XLPE in total hip and knee arthroplasty (THA, TKA. The shape recovery behavior was also monitored via uniaxial compression test at room temperature after non-destructive characterizations of the in-depth microstructure by confocal/polarized Raman spectroscopy. The goal of this study was to relate the manufacturing-induced morphology to the in vivo micromechanical performance, and ultimately to explore an optimal structure in each alternative joint bearing. It was clearly confirmed that the investigated XLPE hip and knee implants, which were produced from different orthopaedic grade resins (GUR 1050 and GUR 1020, consisted of two structural regions in the as-received states: the near-surface transitional anisotropic layer (≈100 μm thickness and the bulk isotropic structural region. These XLPEs exhibited a different crystalline anisotropy and molecular texture within the near-surface layers. In addition, the knee insert showed a slightly higher efficiency of shape recovery against the applied strain over the hip liner owing to a markedly higher percentage of the bulk amorphous phase with intermolecular cross-linking. The quantitative data presented in this study might contribute to construct manufacturing strategies for further rationalized structures as alternative bearings in THA and TKA.

  15. Gender Disparities in Osteoarthritis-Related Health Care Utilization Before Total Knee Arthroplasty.

    Science.gov (United States)

    Bawa, Harpreet S; Weick, Jack W; Dirschl, Douglas R

    2016-10-01

    Women older than 50 years have higher prevalence of knee osteoarthritis (OA) and experience greater functional disability than men. No studies have examined large populations to identify knee OA-related health care utilization differences. The purpose of this investigation was to evaluate gender differences in the utilization of OA-related health care resources in the 12 months preceding total knee arthroplasty (TKA). Truven Health MarketScan Commercial Claims and Encounters and Medicare Supplemental and Coordination of Benefit databases were reviewed from 2005 to 2012. Subjects were included if they underwent TKA, had associated diagnosis of lower leg OA, and were continuously in the database for 12 months preceding TKA. Patient-specific OA-related health care utilization was identified. Multivariate logistic regression analysis controlling for age, region, and Charlson Comorbidity Index was performed to isolate the influence of gender. A total of 244,059 patients with a mean age of 64.8 years consisting of 61.2% women were included. Multivariate logistic regression adjusted odds ratios showed that when compared to men, women were 30%, 20%, 31%, 18%, 19%, 29%, and 39%, more likely to receive a narcotic analgesic, nonnarcotic analgesics, corticosteroid injection, hyaluronic acid injection, knee magnetic resonance imaging, a physical therapy evaluation, and occupational therapy evaluation in the 12 months preceding TKA, respectively. Women have a significantly higher utilization of knee OA-related health care in the 12 months preceding TKA. Although the precise cause for this discrepancy in care cannot be determined from this study, it highlights a potential bias in management of advanced knee OA and directions for further investigation. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Patella position is not a determinant for anterior knee pain 10 years after balanced gap total knee arthroplasty.

    Science.gov (United States)

    van Houten, Albert H; Heesterbeek, Petra J C; Wymenga, Ate B

    2016-08-01

    Incidence of anterior knee pain after total knee arthroplasty (TKA) is reported to be between 4 and 49 %. The incidence of AKP at long-term follow-up and possible determinants after cruciate cruciate-retaining TKA were investigated. A 10-year follow-up of a cohort of 55 patients (63 TKAs), who received the balanSys™ cruciate-retaining total knee system (Mathys Ltd, Bettlach, Switzerland) between 1999 and 2002, was performed. Patients had undergone the balanced gap technique, with either a fixed bearing or an AP-glide bearing. Standardised diagnostic questions regarding AKP were collected and categorised into two groups: those with and without AKP. The lateral patellar tilt, patellar displacement measurement and modified Insall-Salvati ratio were used for patella position evaluation on skyline radiographs. The Knee Society Score (KSS), the Knee Osteoarthritis Outcome Score (KOOS) and Numerical Rating Scales (NRS) for pain and satisfaction were obtained at follow-up. Sixteen patients in the study population experienced AKP. Incidence of AKP (fixed bearing 13/44; AP-glide bearing baring 3/17) was not dependent on type of insert (n.s.). There were no statistical differences in patella position and tibiofemoral contact point between the AKP group and the no AKP group (n.s.). KSS, KOOS, NRS-pain and NRS-satisfaction were significantly lower for the patients with AKP (all p years after balanced gap TKA. Postoperative patella positioning was not found to be a determinant for anterior knee pain after TKA. However, patellar displacement does not seem completely favourable. Moreover, type of bearing was not found a determinant for AKP at long-term follow-up. Lower quality prospective cohort study (<80 % follow-up, patients enrolled at different time points in disease), Level II.

  17. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  18. Investigating the primary stability of the transversal support tibial plateau concept to retain both cruciate ligaments during total knee arthroplasty.

    Science.gov (United States)

    Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor

    2012-09-27

    The important roles of the anterior cruciate ligament regarding knee stability, physiologic kinematics, and proprioception are unquestioned. Thus, various efforts have been made to retain the ACL during total knee arthroplasty (TKA). Neither of the existing solutions to this problem, i.e. bicruciate retaining prostheses and implantation of two unicondylar prostheses, has been successful because of concept-specific problems as well as general difficulties with implant fixation. The new transversal support tibial plateau concept is a prosthesis of two individual joint surfaces reinforced beneath the articular line by joint surface supports and buttressed by a single transversal support. This configuration, which enables retention of both cruciate ligaments, should provide good bone fixation and ensure long-term alignment of the individual joint surfaces. In the current study, four prototypes based on this novel concept were developed and the resulting primary stability was analyzed using adapted load testing. The test set-up, with the model-loading of specially prepared Sawbones® and a sinusoidal oscillating load transmission with 25 000 cycles over 10 increasing load levels, achieved subsidence, which enabled comparison of the four different model variants regarding primary stability in view of bone anchoring. The model variant (TSmobile) that allowed transverse glide of the joint surface supports along the transversal support revealed the largest subsidence. A rigid attachment of the joint surface supports of the transversal support tibial plateau thus appears to offer increased primary stability regarding bone anchoring.

  19. Joint unloading implant modifies subchondral bone trabecular structure in medial knee osteoarthritis: 2-year outcomes of a pilot study using fractal signature analysis

    Directory of Open Access Journals (Sweden)

    Miller LE

    2015-01-01

    Full Text Available Larry E Miller,1,2 Miki Sode,3 Thomas Fuerst,3 Jon E Block2 1Miller Scientific Consulting, Inc., Asheville, NC, USA; 2The Jon Block Group, San Francisco, CA, USA; 3Bioclinica, Newark, CA, USA Background: Knee osteoarthritis (OA is largely attributable to chronic excessive and aberrant joint loading. The purpose of this pilot study was to quantify radiographic changes in subchondral bone after treatment with a minimally invasive joint unloading implant (KineSpring® Knee Implant System.Methods: Nine patients with unilateral medial knee OA resistant to nonsurgical therapy were treated with the KineSpring System and followed for 2 years. Main outcomes included Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC pain, function, and stiffness subscores and independent core laboratory determinations of joint space width and fractal signature of the tibial cortex.Results: WOMAC scores, on average, improved by 92% for pain, 91% for function, and 79% for stiffness over the 2-year follow-up period. Joint space width in the medial compartment of the treated knee significantly increased from 0.9 mm at baseline to 3.1 mm at 2 years; joint space width in the medial compartment of the untreated knee was unchanged. Fractal signatures of the vertically oriented trabeculae in the medial compartment decreased by 2.8% in the treated knee and increased by 2.1% in the untreated knee over 2 years. No statistically significant fractal signature changes were observed in the horizontally oriented trabeculae in the medial compartment or in the horizontal or vertical trabeculae of the lateral compartment in the treated knee.Conclusion: Preliminary evidence suggests that the KineSpring System may modify knee OA disease progression by increasing joint space width and improving subchondral bone trabecular integrity, thereby reducing pain and improving joint function. Keywords: disease modification, KineSpring, joint space, pain, trabecular

  20. Total knee arthroplasty in a pseudoachondroplastic dwarfism patient with bilateral patellar dislocation.

    Science.gov (United States)

    Oh, Kwang-Jun; Yoon, Jung-Ro; Yang, Jae-Hyuk

    2013-01-01

    Late presentation of congenital patellar dislocation with advanced osteoarthritis is rare. This article presents a case of a 59-year-old man with underlying pseudoachondroplastic dwarfism. Advanced osteoarthritis due to bilateral neglected congenital patellar dislocation was treated with total knee arthroplasty without patella relocation surgery. Two years later, the patient had an improvement in Knee Society scores, painless function, and stability. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Application of bone scintigrams in total knee replacement (Okayama MK-II type)

    Energy Technology Data Exchange (ETDEWEB)

    Umeda, T.; Inoue, S.; Matsui, N.; Moriya, H. (Chiba Univ. (Japan). School of Medicine)

    1982-02-01

    Eighteen patients with 21 total knee replacements (OKAYAMA MK-II type) were examined by radionuclide imaging in order to assess the prosthetic complaints such as loosening, infection, fracture and lasting pain. The following results and conclusions were obtained. 1) Bone imaging can reveal the condition of the attachment of bone and prosthesis. 2) Diffuse uptake gradually diminished until 18 months after surgery. 3) In front view on bone imaging, tibial uptake corresponded highly with the part of the weight area. 4) In cases of high uptake of posterior femoral component in lateral view, the range of knee flexion was mostly restricted. 5) Long-period persistent local uptake suggested loosening of the prosthesis or fracture of the tibial plateau. 6) Patello-femoral uptake showed no relation to the patellofemoral complaints. Radionuclide bone imaging is considered to represent one of the most valuable diagnostic procedures for assessing the clinical results after total knee replacement.

  2. Application of bone scintigrams in total knee replacement (Okayama MK-II type)

    International Nuclear Information System (INIS)

    Umeda, Tohru; Inoue, Shunichi; Matsui, Nobuo; Moriya, Hideshige

    1982-01-01

    Eighteen patients with 21 total knee replacements (OKAYAMA MK-II type) were examined by radionuclide imaging in order to assess the prosthetic complaints such as loosening, infection, fracture and lasting pain. The following results and conclusions were obtained. 1) Bone imaging can reveal the condition of the attachment of bone and prosthesis. 2) Diffuse uptake gradually diminished until 18 months after surgery. 3) In front view on bone imaging, tibial uptake corresponded highly with the part of the weight area. 4) In cases of high uptake of posterior femoral component in lateral view, the range of knee flexion was mostly restricted. 5) Long-period persistent local uptake suggested loosening of the prosthesis or fracture of the tibial plateau. 6) Patello-femoral uptake showed no relation to the patellofemoral complaints. Radionuclide bone imaging is considered to represent one of the most valuable diagnostic procedures for assessing the clinical results after total knee replacement. (author)

  3. Knee strength retention and analgesia with continuous perineural fentanyl infusion after total knee replacement: randomized controlled trial.

    Science.gov (United States)

    Mangar, Devanand; Karlnoski, Rachel A; Sprenker, Collin J; Downes, Katheryne L; Taffe, Narrene; Wainwright, Robert; Gustke, Kenneth; Bernasek, Thomas L; Camporesi, Enrico

    2014-04-01

    Despite providing adequate pain relief, a femoral nerve block can induce postoperative muscle weakness after total knee arthoplasty (TKA). Fentanyl has been shown to have peripheral effects but has not been used as a perineural infusate alone after TKA. Sixty patients scheduled for TKA were randomized to one of three blinded groups: a continuous 24 h infusion of either fentanyl 3 μg/ml, ropivacaine 0.1%, or 0.9% normal saline through a femoral nerve sheath catheter at 10 ml/h. The main outcome was maximum voluntary isometric contraction (MVIC) in the quadriceps femoris (knee extension), measured by a handheld dynamometer (Nm/kg). Other variables assessed were preoperative and postoperative visual analog scale (VAS) scores, hamstrings MVIC (knee flexion), active range of motion of the operative knee, distance ambulated, incidence of knee buckling, supplemental morphine usage, postoperative side effects, and serum fentanyl levels. Quadriceps MVIC values were significantly greater in the fentanyl group compared to the group that received ropivacaine (median values, 0.08 vs. 0.03 Nm/kg; p = 0.028). The incidence of postoperative knee buckling upon ambulation was higher in the ropivacaine group compared to the fentanyl group, although not statistically significant (40% vs. 15 %, respectively; p = 0.077). VAS scores while ambulating were not significantly different between the fentanyl group and the ropivacaine group (p = 0.270). Postoperative morphine consumption, nausea and vomiting, and resting VAS scores were similar among the three groups. A continuous perineural infusion of fentanyl produced greater strength retention than ropivacaine post-TKA.

  4. Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Awengen, R.; Hirschmann, M.T. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Rasch, H. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Institute of Radiology and Nuclear Medicine, Bruderholz (Switzerland); Amsler, F. [Amsler Consulting, Basel (Switzerland)

    2016-04-15

    The primary purpose of this retrospective study was to evaluate the differences of bone tracer uptake (BTU) in symptomatic and asymptomatic knees after bilateral total knee arthroplasty (TKA) and identify typical BTU patterns with regards to TKA component position and alignment. A consecutive number of 37 patients after bilateral TKA were retrospectively included. The knees were grouped into symptomatic (group A) and asymptomatic (group B) knees. All patients underwent 99m-Tc-HDP-SPECT/CT. Coronal, rotational, and sagittal TKA component position was analysed in 3D reconstructed CT. BTU was anatomically localised and quantified using a validated standardized localization scheme. Maximum BTU values for each area were recorded and normalized values calculated. Signed log-rank test, chi-square test, paired t-tests, and Pearson correlations were used (p <0.05). Symptomatic TKAs were significantly more flexed and had a tendency to be more internally rotated when compared to asymptomatic ones (p < 0.05). In all regions, the mean BTU in asymptomatic knees was lower than in symptomatic knees. In both groups the highest mean BTU was found around the tibial stem (symptomatic 7.30; asymptomatic 6.30, p = 0.061) and at the tip of the tibial stem (symptomatic 5.49; asymptomatic 4.74, p = 0.062). Superior patellar regions showed higher BTU than inferior regions. The highest patellar BTU was found in the superior medial patella (symptomatic 4.99; asymptomatic 3.98, p = 0.048). The lowest BTU was found in the posterior femoral regions (flatsp, flatip, fmedsp, fmedip) (Table 3). Tibial and patellar areas showed twice as high mean BTUs than femoral areas (Fig. 3). A significant correlation of TKA component position and BTU was demonstrated. Distribution and intensity of BTU in SPECT/CT depends on TKA component position and alignment. In addition, typical BTU patterns in symptomatic and asymptomatic knees were identified. A profound knowledge of BTU pattern, TKA component position

  5. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis - A Cox model analysis.

    Science.gov (United States)

    Delbarre, Angélique; Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee replacement and show that patients treated with hyaluronic acid have similar direct medical costs for ambulatory care compared to patients treated with corticosteroids only.

  6. Total knee replacement in a resource constrained environment: A ...

    African Journals Online (AJOL)

    Introduction: Total knee replacement surgery is relatively new in Nigeria and available in few centres only. It has been evolving at a slow pace because of the lack of facilities, structures and adequate surgical expertise alongside patient ignorance and poverty. Objective: The aim of this article is to review the cases done in a ...

  7. Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Mikkel Rathsach; Winther, Nikolaj; Lind, Thomas

    2016-01-01

    Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial...

  8. The manufacture of generic replicas of implants for arthroplasty of the hip and knee: is it regulated and will it save money?

    Science.gov (United States)

    Atrey, A; Heylen, S; Gosling, O; Porteous, M J L; Haddad, F S

    2016-07-01

    Joint replacement of the hip and knee remain very satisfactory operations. They are, however, expensive. The actual manufacturing of the implant represents only 30% of the final cost, while sales and marketing represent 40%. Recently, the patents on many well established and successful implants have expired. Companies have started producing and distributing implants that purport to replicate existing implants with good long-term results. The aims of this paper are to assess the legality, the monitoring and cost saving implications of such generic implants. We also assess how this might affect the traditional orthopaedic implant companies. Cite this article: Bone Joint J 2016;98-B:892-900. ©2016 The British Editorial Society of Bone & Joint Surgery.

  9. Postoperative pain treatment after total knee arthroplasty

    DEFF Research Database (Denmark)

    Karlsen, Anders Peder Højer; Wetterslev, Mik; Hansen, Signe Elisa

    2017-01-01

    INTRODUCTION: The aim of this systematic review was to document efficacy, safety and quality of evidence of analgesic interventions after total knee arthroplasty (TKA). METHODS: This PRISMA-compliant and PROSPERO-registered review includes all-language randomized controlled trials of medication......), to 19 mm (CI: 8, 31; single FNB), and at 24 hours from 3 mm (CI: -2, 8; gabapentinoids), to 16 mm (CI: 8, 23; continuous FNB). GRADE-rated quality of evidence was generally low. CONCLUSION: A low quality of evidence, small sample sizes and heterogeneity of trial designs prohibit designation...

  10. Contemporary pain management in total knee arthroplasty.

    Science.gov (United States)

    Khanasuk, Yutthana; Ngarmukos, Srihatach

    2012-10-01

    Pain management has become a very important part of postoperative care for total knee arthroplasty patients. Contemporary pain control has evolved from high-dose opioid in the past to state-of-the-art multimodal regimens. These include multiple non-opioid medication such as NSAIDs, COX-2 inhibitors, and gabapentinoid, and novel anesthetic techniques such as preemptive analgesia and ultrasound-guided peripheral nerve blocks. Another method which is gaining popularity is intraarticular injection of anesthetic cocktail during surgery. Pre-op education can also help patients cope with their pain better.

  11. Early morbidity after simultaneous and staged bilateral total knee arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer Calov; Husted, Henrik

    2015-01-01

    PURPOSE: The aim of this nationwide study was to investigate the early morbidity after bilateral simultaneous and staged total knee arthroplasty (TKA) in order to clarify potential benefits of a well-established fast-track regime. METHODS: The Danish National Patient Registry was searched for all...

  12. Patient-controlled oral analgesia for postoperative pain management following total knee replacement.

    Science.gov (United States)

    Kastanias, Patti; Gowans, Sue; Tumber, Paul S; Snaith, Kianda; Robinson, Sandra

    2010-01-01

    To investigate whether patient-controlled oral analgesia (PCOA) used by individuals receiving a total knee replacement could reduce pain, increase patient satisfaction, reduce opioid use and/or reduce opioid side effects when compared with traditional nurse (RN)-administered oral analgesia. Patients who underwent an elective total knee replacement at a quaternary care centre (Toronto Western Hospital, Toronto, Ontario) were randomly assigned to either PCOA or RN-administered short-acting oral opioids on postoperative day 2. Subjects in the RN group called the RN to receive their prescribed short-acting opioid. Subjects in the PCOA group kept a single dose of their prescribed oral opioid at their bedside and took this dose when they felt they needed it, to a maximum of one dose every 2 h. Study outcomes, collected on postoperative day 2, included pain (measured by the Brief Pain Inventory - Short Form), patient satisfaction (measured by the Pain Outcome Questionnaire Satisfaction subscale - component II), opioid use (oral morphine equivalents), opioid side effects (nausea, pruritus and/or constipation) and knee measures (maximum passive knee flexion and pain at maximum passive knee flexion, performed on the operative knee). Study outcomes were analyzed twice. First, for a subset of 73 subjects who remained in their randomly assigned group (PCOA group, n=36; RN group, n=37), randomized analyses were performed. Second, for the larger sample of 88 subjects who were categorized by their actual method of receiving oral opioids (PCOA group, n=41; RN group, n=47), as-treated analyses were performed. There were no differences in study outcomes between the PCOA and RN groups in either analysis. PCOA was not superior to RN administration on study outcomes. However, PCOA did not increase opioid use or pain. PCOA remains an important element in the patient-centred care facility.

  13. Selective Denervation for Persistent Knee Pain After Total Knee Arthroplasty: A Report of 50 Cases.

    Science.gov (United States)

    Shi, Shao-Min; Meister, David W; Graner, Kelly C; Ninomiya, James T

    2017-03-01

    Despite the general success of total knee arthroplasty (TKA), up to 20% of patients report dissatisfaction following surgery. One potential cause of this dissatisfaction is residual pain secondary to neuroma formation in the sensory nerve branches that innervate the knee. We found, after performing a retrospective review, that up to 9.7% of patients following primary TKA and up to 21% of revision cases exhibited persistent knee pain attributable to neuroma formation. Despite the high incidence of this pathology, little is known about the effective diagnosis or treatment of neuroma formation following TKA. Between 2011 and 2014, 50 patients with persistent symptomatic neuroma pain following TKA underwent selective denervation. These patients had demonstrated the appropriate selection criteria and had failed conservative management. Patients were evaluated by the visual analog scale pain score and the Knee Society Score to determine the outcome of the described treatment. Thirty-two patients (64%) rated their outcome as excellent, 10 (20%) as good, 3 (6%) as fair, and 2 (4%) reported no change. The mean visual analog scale pain score was improved from 9.4 ± 0.8 to 1.1 ± 1.6 following surgery (P ≤ .001). The mean Knee Society Scores increased from 45.5 ± 14.3 to 94.1 ± 8.6 points (P ≤ .0001). Three patients (6%) required the second neurectomy due to recurrent pain and received excellent pain relief postoperatively. There were 2 complications of superficial skin peri-incisional hyperemia related to dressings. Average follow-up duration was 24 months (range, 16-38 months). Our study suggests that selective denervation provides an effective and long-lasting option for the management of this pathology. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Patient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data

    Directory of Open Access Journals (Sweden)

    Andrzej Kotela

    2015-01-01

    Full Text Available Total knee arthroplasty (TKA is a frequently performed procedure in orthopaedic surgery. Recently, patient-specific instrumentation was introduced to facilitate correct positioning of implants. The aim of this study was to compare the early clinical results of TKA performed with patient-specific CT-based instrumentation and conventional technique. A prospective, randomized controlled trial on 112 patients was performed between January 2011 and December 2011. A group of 112 patients who met the inclusion and exclusion criteria were enrolled in this study and randomly assigned to an experimental or control group. The experimental group comprised 52 patients who received the Signature CT-based implant positioning system, and the control group consisted of 60 patients with conventional instrumentation. Clinical outcomes were evaluated with the KSS scale, WOMAC scale, and VAS scales to assess knee pain severity and patient satisfaction with the surgery. Specified in-hospital data were recorded. Patients were followed up for 12 months. At one year after surgery, there were no statistically significant differences between groups with respect to clinical outcomes and in-hospital data, including operative time, blood loss, hospital length of stay, intraoperative observations, and postoperative complications. Further high-quality investigations of various patient-specific systems and longer follow-up may be helpful in assessing their utility for TKA.

  15. Comparison of clinical outcomes between total knee arthroplasty and unicompartmental knee arthroplasty for osteoarthritis of the knee: a retrospective analysis of preoperative and postoperative results.

    Science.gov (United States)

    Horikawa, Akira; Miyakoshi, Naohisa; Shimada, Yoichi; Kodama, Hiroyuki

    2015-10-28

    Excellent results have recently been reported for both total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA), but there have been few reports about which has a better long-term outcome. The preoperative and postoperative results of TKA and UKA for osteoarthritis of the knee were thus compared. The results of 48 patients who underwent TKA and 25 patients who underwent UKA were evaluated based on clinical scores and survivorship in the middle long-term period. Preoperative, latest postoperative, and changes in the femoro-tibial angle (FTA), range of motion (ROM), Japanese Orthopedic Association score (JOA score), and Japanese Knee Osteoarthritis Measure (JKOM) were compared. The patients' mean age was 73 years. The mean follow-up period was 9 years (TKA: mean, 10.5 years; range, 7-12 years; UKA: mean, 9 years; range, 6-11 years). Preoperative FTA and ROM were significantly higher in the UKA group than in the TKA group. Total changes in all scores were similar among the two groups, as were changes in scores for all JOA and JKOM domains. The cumulative revision rate was higher for UKA than for TKA (7 versus 4%). Kaplan-Meier survivorship at 10 years was 84% for UKA and 92% for TKA. This clinical study found no significant differences between TKA and UKA, except in long-term survivorship.

  16. Posterior Slope of the Tibia Plateau in Malaysian Patients Undergoing Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    R Yoga

    2009-05-01

    Full Text Available The posterior slope of the tibial plateau is an important feature to preserve during knee replacement. The correct slope aids in the amount of flexion and determines if the knee will be loose on flexion. This is a study on the posterior tibial plateau slope based on preoperative and postoperative radiographs of 100 consecutive patients who had total knee replacements. The average posterior slope of the tibia plateau was 10.1 degrees. There is a tendency for patients with higher pre-operative posterior tibial plateau slope to have higher post-operative posterior tibial plate slope.

  17. Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices.

    Directory of Open Access Journals (Sweden)

    Anna R Gagliardi

    Full Text Available Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants.A review of primary studies included in health technology assessments (HTA on total (TKA and unicompartmental knee arthroplasty (UKA was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics.A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias. Most evaluated TKA (198, 74.5%. The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8% or offered no declaration of funding or conflict of interest (44.9%; based on uncontrolled single cohorts (58.5%, enrolled fewer than 100 patients (66.4%, and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%. Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants.Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened.

  18. An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty.

    Science.gov (United States)

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi

    2013-05-01

    Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Analgesic effect of continuous femoral nerve block combined with infiltration anesthesia after total knee replacement

    OpenAIRE

    Jian-Guo Tan

    2016-01-01

    Objective: To study the analgesic effect of continuous femoral nerve block combined with infiltration anesthesia after total knee replacement. Methods: Patients who received unilateral total knee replacement in our hospital from May 2012 to August 2015 were included for study and randomly divided into experimental group who received continuous femoral nerve block combined with infiltration anesthesia and control group who received continuous femoral nerve block, and then the co...

  20. [Clinical factors and findings in knee arthroscopy of patients with knee arthrosis candidates for conversion to total replacement].

    Science.gov (United States)

    Figueroa, D; Calvo, R; Villalón, I; Tuca, M J; Vaisman, A; Valdés, M

    2013-01-01

    To identify those clinical characteristic and arthroscopic findings in patients with knee arthrosis that are associated with worsening of the disease and subsequent total knee arthroplasty (TKA). A retrospective, descriptive study was conducted on 78 consecutive patients (88 knees) who underwent knee arthroscopy for arthrosis. The study included 44 women and 34 men, with a mean age of 58.9 years (range: 37-78 years). After a mean follow-up of 50.4 months (range: 12-96 months), those patients who progressed towards TKA were identified. A logistic regression model was applied to recognise the factors associated with deterioration of the arthrosis, with consequent progression towards a TKA. Twenty-four out of the 88 knees progressed towards a TKA (27.3%) within a mean time of 13.5 months after arthroscopy (range: 13-29 months). The clinical characteristics that showed a significant association with poor progression of the arthrosis were: female gender (0.02) and Ahlbäck 2 (P=.04). Arthroscopic finding that proved significant correlation with worsening of the arthrosis towards TKA were: meniscal tears of the posterior horn (P=.02), meniscectomies above 60% (P=.03), and 2nd degree chondral lesions in loading areas of the medial femoral condyle (P=.02). The variables associated with a greater chance of progressing towards a TKA after a knee arthroscopy due to arthrosis in this study were, female gender, grade 2 radiographic arthrosis, posterior horn meniscal lesions, meniscectomies over 60%, and chondral lesions in loading area of the medial femoral condyle. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  1. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis – A Cox model analysis

    Science.gov (United States)

    Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    Due to the growing worldwide prevalence of knee osteoarthritis, the optimal management of this issue is critical for reducing its burden. Objectives This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Materials and methods Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. Results A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. Conclusion This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee

  2. Augmented Reality for Assistance of Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Castillo Daniel

    2016-01-01

    Full Text Available The aim of this work was the development of a surgical assistance system based on augmented reality to support joint replacement procedures and implantation of prosthetic knee. Images of the scene were captured in order to detect the visual markers located on the lateral surface of the patient’s leg for overlapping the 3D models of the prosthesis and the joint, as well as the tool used by the medical specialist. With the marker identification, it was possible to compute its position and orientation for locating the virtual models, obtaining a monitoring system for giving accurate information about the procedure. Also it can be used as training platform for surgeons, without having volunteers or patients for performing real surgeries; instead they can train in a virtual environment. The results have shown an efficient system in terms of cost-benefit relation, taking into account the materials used for developing the system; nevertheless, the accuracy of the algorithm decreases according to the distance between the markers.

  3. Incidence of Early Post Operative Infection after Primary Total Knee ...

    African Journals Online (AJOL)

    Incidence of Early Post Operative Infection after. Primary Total Knee Arthroplasty at an East African. Centre. Kigera JWM1, Kimpiatu P2. 1. School of Medicine, University of Nairobi. 2. PCEA Kikuyu Hospital. Correspondence to: Dr James Kigera, P.O Box 30197 – 00100 Nairobi. Email: jameskigera@yahoo.co.uk. Abstract.

  4. A Facile Technique to Make Articulating Spacers for Infected Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Yu-Ping Su

    2009-03-01

    Conclusion: Treating infected total knee arthroplasty with these self-made articulating spacers eradicates infection effectively, improves the life quality before reimplantation and provides good final results without significant complications.

  5. [Total knee and hip prosthesis: variables associated with costs].

    Science.gov (United States)

    Herrera-Espiñeira, Carmen; Escobar, Antonio; Navarro-Espigares, José Luis; Castillo, Juan de Dios Lunadel; García-Pérez, Lidia; Godoy-Montijano, Amparo

    2013-01-01

    The elevated prevalence of osteoarthritis in Western countries, the high costs of hip and knee arthroplasty, and the wide variations in the clinical practice have generated considerable interest in comparing the associated costs before and after surgery. To determine the influence of a number of variables on the costs of total knee and hip arthroplasty surgery during the hospital stay and during the one-year post-discharge. A prospective multi-center study was performed in 15 hospitals from three Spanish regions. Relationships between the independent variables and the costs of hospital stay and postdischarge follow-up were analyzed by using multilevel models in which the "hospital" variable was used to group cases. Independent variables were: age, sex, body mass index, preoperative quality of life (SF-12, EQ-5 and Womac questionnaires), surgery (hip/knee), Charlson Index, general and local complications, number of beds and economic-institutional dependency of the hospital, the autonomous region to which it belongs, and the presence of a caregiver. The cost of hospital stay, excluding the cost of the prosthesis, was 4,734 Euros, and the post-discharge cost was 554 Euros. With regard to hospital stay costs, the variance among hospitals explained 44-46% of the total variance among the patients. With regard to the post-discharge costs, the variability among hospitals explained 7-9% of the variance among the patients. There is considerable potential for reducing the hospital stay costs of these patients, given that more than 44% of the observed variability was not determined by the clinical conditions of the patients but rather by the behavior of the hospitals.

  6. Correlations between commonly used clinical outcome scales and patient satisfaction after total knee arthroplasty.

    Science.gov (United States)

    Kwon, Sae Kwang; Kang, Yeon Gwi; Kim, Sung Ju; Chang, Chong Bum; Seong, Sang Cheol; Kim, Tae Kyun

    2010-10-01

    Patient satisfaction is becoming increasingly important as a crucial outcome measure for total knee arthroplasty. We aimed to determine how well commonly used clinical outcome scales correlate with patient satisfaction after total knee arthroplasty. In particular, we sought to determine whether patient satisfaction correlates better with absolute postoperative scores or preoperative to 12-month postoperative changes. Patient satisfaction was evaluated using 4 grades (enthusiastic, satisfied, noncommittal, and disappointed) for 438 replaced knees that were followed for longer than 1 year. Outcomes scales used the American Knee Society, Western Ontario McMaster University Osteoarthritis Index scales, and Short Form-36 scores. Correlation analyses were performed to investigate the relation between patient satisfaction and the 2 different aspects of the outcome scales: postoperative scores evaluated at latest follow-ups and preoperative to postoperative changes. The Western Ontario McMaster University Osteoarthritis Index scales function score was most strongly correlated with satisfaction (correlation coefficient=0.45). Absolute postoperative scores were better correlated with satisfaction than the preoperative to postoperative changes for all scales. Level IV (retrospective case series). Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Patient outcomes using Wii-enhanced rehabilitation after total knee replacement - the TKR-POWER study.

    Science.gov (United States)

    Negus, J J; Cawthorne, D P; Chen, J S; Scholes, C J; Parker, D A; March, L M

    2015-01-01

    Home-based rehabilitation following total knee replacement surgery can be as effective as clinic-based or in-patient rehabilitation. The use of the Nintendo Wii has been postulated as a novel rehabilitation tool that adds an additional focus on balance and proprioception into the recovery protocol. The aim of the proposed clinical trial is to investigate the effectiveness of this novel rehabilitation tool, used at home for three months after total knee replacement surgery and to assess any lasting improvements in functional outcome at one year. This will be a randomised controlled trial of 128 patients undergoing primary total knee replacement. The participants will be recruited preoperatively from three surgeons at a single centre. There will be no change to the usual care provided until 6 weeks after the operation. Then participants will be randomised to either the Wii-Fit group or usual rehabilitative care group. Outcomes will be assessed preoperatively, a 6-week post surgery baseline and then at 18 weeks, 6 months and 1 year. The primary outcome is the change in self-reported WOMAC total score from week 6 to 18 weeks. Secondary outcomes include objective measures of strength, function and satisfaction scores. The results of this clinical trial will be directly relevant for implementation into clinical practice. If beneficial, this affordable technology could be used by many patients to rehabilitate at home. Not only could it optimize the outcomes from their total knee replacement surgery but decrease the need for clinic-based or outpatient therapy for the majority. (ACTRN12611000291987). Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Knee joint loading in knee osteoarthritis: influence of abdominal and thigh fat.

    Science.gov (United States)

    Messier, Stephen P; Beavers, Daniel P; Loeser, Richard F; Carr, J Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J; Hunter, David J; Devita, Paul

    2014-09-01

    Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee joint loads in older overweight and obese adults with knee osteoarthritis (OA). Fat depots were quantified using computed tomography, and total lean and fat mass were determined with dual energy x-ray absorptiometry in 176 adults (age, 66.3 yr; body mass index, 33.5 kg·m) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Higher total body mass was significantly associated (P ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (P knee extensor moments (P = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (P = 0.0001), shear (P knee extension moment (P = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (P = 0.002). A regression model that included total thigh and total abdominal fat found that both were significantly associated with knee compressive and shear forces (P ≤ 0.04). Thigh fat was associated with knee abduction (P = 0.03) and knee extension moment (P = 0.02). Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA.

  9. Effects of preoperative walking ability and patient's surgical education on quality of life and functional outcomes after total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Sunil K. Dash

    Full Text Available ABSTRACT OBJECTIVE: Prospectively analyze the effect of preoperative walking status and the patient's surgical education on functional outcomes and the three dimensions of quality of life (QoL (pain, physical function, and mental health after elective total knee arthroplasty (TKA. METHODS: A comparative analysis on the QoL and functional outcomes in patients who underwent total knee arthroplasty between January 2014 and June 2015. To compare effects of the patient's walking status and knowledge of the surgical procedure on QoL and functional outcomes following TKA by means of SF-36 questionnaire, CES D10, VAS, KSS, KSFS, WOMAC, as well as Friedmann and Wyman scores, 10MWT, and 30-second timed chair test, assessed before the operation and one, three, and six months after the operation. RESULTS: There were 168 knees in 154 patients: 46.75% men and 53.24% women. 52.38% of knees had grade-III OA and 40.47% of knees had grade-IV OA. Preoperatively, SF-36 PCS was 33.2 and MCS was 35.4. Mean KSS and KSFS in females was 37.3 (16.2 and 31.5 (13.8; in males it was 49.2 (18.4 and 42.5 (15.7, respectively. Mean WOMAC scores were 64.2 in females and 56.5 in males. Mean VAS and CES D10 scores were 8.8 and 8.2 in females, and 6.9 and 6.4 in males, respectively. Post operatively at the first, third, and sixth month, significant improvements in QoL and mean SF-36, CES D10, VAS, KSS, KSFS, WOMAC, and Friedmann and Wyman scores were observed, as well as in the 10MWT and 30 s timed chair test scores. Patients with better preoperative functional activity and satisfactory understanding of TKA presented a better functional performance and achieved a good quality life (p< 0.01. DISCUSSION: Surgeons educate TKA candidates regarding the surgical procedure, the nature of implants, and how the procedure would affect their lifestyle and what their expectations from TKA should be. These crucial considerations should boost their confidence, enhancing their involvement and

  10. Radiographic pseudochondrocalcinosis in early failure of a cemented total knee replacement

    NARCIS (Netherlands)

    Kloen, P.; Burke, D. W.; Chew, F. S.; Mildrum, R.

    1998-01-01

    We observed a case of early-onset osteolysis in a cemented total knee arthroplasty. Preoperative radiographs suggested numerous radiopaque particles covering the polyethylene insert. Findings at the time of revision confirmed the presence of small radiopaque polymethylmethacrylate particles on the

  11. Circuit training enhances function in patients undergoing total knee arthroplasty: a retrospective cohort study.

    Science.gov (United States)

    Hsu, Wei-Hsiu; Hsu, Wei-Bin; Shen, Wun-Jer; Lin, Zin-Rong; Chang, Shr-Hsin; Hsu, Robert Wen-Wei

    2017-10-19

    The number of patients receiving total knee arthroplasty (TKA) has been rising every year due to the aging population and the obesity epidemic. Post-operative rehabilitation is important for the outcome of TKA. A series of 34 patients who underwent primary unilateral TKA was retrospectively collected and divided into either exercise group (n = 16) and control group (n = 18). The exercise group underwent a 24-week course of circuit training beginning 3 months after total knee arthroplasty (TKA). The effect of circuit training on TKA patients in terms of motion analysis, muscle strength testing, Knee injury and Osteoarthritis Outcomes Score (KOOS) questionnaire and patient-reported outcome measurement Short-Form Health Survey (SF-36) at the pre-operation, pre-exercise, mid-exercise, and post-exercise. Motion analysis revealed the stride length, step velocity, and excursion of active knee range of motion significantly improved in the exercise group when compared to those in the control group. KOOS questionnaire showed a greater improvement in pain, ADL, and total scores in the exercise group. The SF-36 questionnaire revealed a significant improvement in general health, bodily pain, social function, and physical components score in the exercise group. The post-operative circuit training intervention can facilitate recovery of knee function and decrease the degree of pain in the TKA and might be considered a useful adjunct rehabilitative modality. The ultimate influence of circuit training on TKA needs further a prospective randomized clinical trial study and long-term investigation. NCT02928562.

  12. Early Experience with a Modern Generation Knee System: Average 2 Years’ Follow-up

    Directory of Open Access Journals (Sweden)

    Thomas Paszicsnyek

    2015-12-01

    Full Text Available Arthritis in the knee is a leading cause of pain and disability with total knee arthroplasty (TKA often the treatment of choice after failure of more conservative treatments. TKA has been demonstrated to be one of the most successful procedures performed.  However, despite the good long-term survivorship rates, patient satisfaction is still an issue post TKA with over 20% of patients exhibiting patient dissatisfaction most commonly due to anterior knee pain (over 18-28% patients and mediolateral or varus-valgus instability.  Recent studies have demonstrated that collateral ligament strains are altered post TKA which may lead to laxity and/or tightness of the ligaments resulting in patient discomfort, pain, stiffness and/or instability post TKA.  As a result, it may be beneficial to ensure ligamentous strains after TKA are similar or close to the native situation.  The purpose of this study was to evaluate the clinical and radiographic results of the Unity Knee™ Total Knee System (Corin Ltd, Cirencester, UK, a modern generation, single-radius total knee replacement (TKR and its accompanying instrumentation which is designed to help maintain proper ligament balance and restore the medial jointline.  A total of 89 knees (89 patients were implanted with the device in a single surgeon series.  All patients were assessed using the American Knee Society Score (AKSS, the Oxford Knee Score (OKS, and radiographs.  There was 1 revision due to infection and Kaplan-Meier survivorship was 98.9% at 2 years.  The mean AKSS knee score for the total cohort was 87.1 ± 7.98 and the mean Oxford Knee score was 45.89 + 3.69. Radiographic review found no signs of radiographic failure in any of the knees. This study demonstrates good survivorship, clinical, and radiographic results at 2 years for this TKR.

  13. Patellar resurfacing versus nonresurfacing in total knee arthroplasty for osteoarthritis: experience at a tertiary care institution in Pakistan

    Directory of Open Access Journals (Sweden)

    Lakdawala RH

    2012-02-01

    Full Text Available Akil Fazal1, Riaz H Lakdawala21Clinical Fellow, NYU Hospital for Joint Disease, New York, US; 2Associate Professor and Chief, Section of Orthopedics, Department of Surgery, The Aga Khan University Hospital, Karachi, PakistanObjective: To determine the effect of patellar resurfacing in patients offered total knee arthroplasty for osteoarthritis.Design: Randomized control study.Place and duration of study: The Aga Khan University Hospital, Karachi, Pakistan from January 3, 2005 to January 9, 2010.Patients and methods: Patients undergoing primary total knee arthroplasty for osteoarthritis were assigned to either the patellar resurfacing or nonresurfacing arm using systematic sampling. This consisted of patients undergoing unilateral and bilateral knee arthroplasty. Preoperatively, Knee Society Knee and Function Scores were calculated. After a minimum of 3 years postoperatively Knee Society Knee and Function Scores as well as the Clinical Anterior Knee Pain Rating were calculated and analysis done to check for differences.Results: Seventy-five patients were recruited in each arm; 135 patients had bilateral and 15 had unilateral knee arthroplasty. The mean preoperative knee score was 40.4 for the resurfacing group and 40.60 for the nonresurfacing group (P = 0.45. This improved postoperatively to 93.67 and 94.23 respectively, with no difference between the two groups (P = 0.67. The mean preoperative function score was 45.50 for resurfaced patellae and 45.83 for nonresurfaced. This improved to 89.67 and 90.50, respectively, again with no difference (P = 0.51. Postoperative Clinical Anterior Knee Pain Rating was a mean of 0.1 for resurfaced and 0.13 for nonresurfaced patellas, with no difference on analysis (P = 0.06. However, patients who had bilateral knee arthroplasty had a slightly higher Clinical Anterior Knee Pain Rating than those who had single knee surgery (P = 0.046 irrespective of whether the patellar was resurfaced or not.Conclusion: In

  14. Value of radiographic examination of the knee joint for the orthopedic surgeon

    International Nuclear Information System (INIS)

    Pietsch, M.; Hofmann, S.

    2006-01-01

    Extended radiographic examinations offer excellent options for diagnosis and strategy for treatment of the knee joint. The whole-leg radiograph is indispensable in measuring alignment for osteotomy or total knee arthroplasty (TKA). Fluoroscopically assisted varus-valgus stress radiographs provide the possibility for verifying mechanical function of the implanted knee prosthesis. Ultrasound examinations have been widely replaced by magnetic resonance imaging (MRI). MRI is the golden standard to examine intra-articular structures of the knee (meniscus, ligaments, cartilage) and surrounding soft tissue. For evaluating femoral and tibial torsion and determining axial rotation of TKA, computed tomography (CT) is best qualified. Imaging of the patellofemoral joint (patella instability) is difficult; CT scans in combination with true lateral radiographs seem to be helpful. (orig.) [de

  15. Iodine-impregnated incision drape and bacterial recolonization in simulated total knee arthroplasty.

    Science.gov (United States)

    Milandt, Nikolaj; Nymark, Tine; Jørn Kolmos, Hans; Emmeluth, Claus; Overgaard, Søren

    2016-08-01

    Background and purpose - Iodine-impregnated incision drapes (IIIDs) are used to prevent surgical site infection (SSI). However, there is some evidence to suggest a potential increase in SSI risk as a result of IIID use, possibly from promotion of skin recolonization. A greater number of viable bacteria in the surgical field of an arthroplasty, and surgery in general, may increase the infection risk. We investigated whether IIID use increases bacterial recolonization compared to no drape use under conditions of simulated total knee arthroplasty (TKA). Methods - 20 patients scheduled for TKA were recruited. Each patient had 1 knee randomized for draping with IIID, while the contralateral knee was left bare. The patients thus served as their own control. The operating room conditions and perioperative procedures of a TKA were simulated. Cylinder samples were collected from the skin of each knee prior to disinfection, and again on 2 occasions after skin preparation-75 min apart. Quantities of bacteria were estimated using a spread plate technique under aerobic conditions. Results - We found similar quantities of bacteria on the intervention and control knees immediately after skin disinfection and after 75 min of simulated surgery. These quantities had not increased at the end of surgery when compared to baseline, so no recolonization was detected on the draped knees or on the bare knees. Interpretation - The use of IIIDs did not increase bacterial recolonization in simulated TKA. This study does not support the hypothesis that IIIDs promote bacterial recolonization and postoperative infection risk.

  16. Early patient-reported outcomes versus objective function after total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Luna, I E; Kehlet, H; Peterson, B

    2017-01-01

    AIMS: The purpose of this study was to assess early physical function after total hip or knee arthroplasty (THA/TKA), and the correlation between patient-reported outcome measures, physical performance and actual physical activity (measured by actigraphy). PATIENTS AND METHODS: A total of 80...... patients aged 55 to 80 years undergoing THA or TKA for osteoarthritis were included in this prospective cohort study. The main outcome measure was change in patient reported hip or knee injury and osteoarthritis outcome score (HOOS/KOOS) from pre-operatively until post-operative day 13 (THA) or 20 (TKA...

  17. Effects of adductor-canal-blockade on pain and ambulation after total knee arthroplasty

    DEFF Research Database (Denmark)

    Jenstrup, M T; Jæger, P; Lund, J

    2012-01-01

    Total knee arthroplasty (TKA) is associated with intense post-operative pain. Besides providing optimal analgesia, reduction in side effects and enhanced mobilization are important in this elderly population. The adductor-canal-blockade is theoretically an almost pure sensory blockade. We hypothe...... hypothesized that the adductor-canal-blockade may reduce morphine consumption (primary endpoint), improve pain relief, enhance early ambulation ability, and reduce side effects (secondary endpoints) after TKA compared with placebo.......Total knee arthroplasty (TKA) is associated with intense post-operative pain. Besides providing optimal analgesia, reduction in side effects and enhanced mobilization are important in this elderly population. The adductor-canal-blockade is theoretically an almost pure sensory blockade. We...

  18. Impact of preoperative antithrombotic therapy on blood management after implantation of primary total knee arthroplasty.

    Science.gov (United States)

    Leitner, Lukas; Musser, Ewald; Kastner, Norbert; Friesenbichler, Jörg; Hirzberger, Daniela; Radl, Roman; Leithner, Andreas; Sadoghi, Patrick

    2016-08-04

    Red blood cell concentrates (RCC) substitution after total knee arthroplasty (TKA) is correlated with multifold of complications and an independent predictor for higher postoperative mortality. TKA is mainly performed in elderly patients with pre-existing polymorbidity, often requiring permanent preoperative antithrombotic therapy (PAT). The aim of this retrospective analysis was to investigate the impact of demand for PAT on inpatient blood management in patients undergoing TKA. In this study 200 patients were retrospectively evaluated after TKA for differences between PAT and non-PAT regarding demographic parameters, preoperative ASA score > 2, duration of operation, pre-, and intraoperative hemoglobin level, and postoperative parameters including amount of wound drainage, RCC requirement, and inpatient time. In a multivariate logistic regression analysis the independent influences of PAT, demographic parameters, ASA score > 2, and duration of the operation on RCC demand following TKA were analyzed. Patients with PAT were significantly older, more often had an ASA > 2 at surgery, needed a higher number of RCCs units and more frequently and had lower perioperative hemoglobin levels. Multivariate logistic regression revealed PAT was an independent predictor for RCC requirement. PAT patients are more likely to require RCC following TKA and should be accurately monitored with respect to postoperative blood loss.

  19. Autologous chondrocyte implantation: Is it likely to become a saviour of large-sized and full-thickness cartilage defect in young adult knee?

    Science.gov (United States)

    Zhang, Chi; Cai, You-Zhi; Lin, Xiang-Jin

    2016-05-01

    A literature review of the first-, second- and third-generation autologous chondrocyte implantation (ACI) technique for the treatment of large-sized (>4 cm(2)) and full-thickness knee cartilage defects in young adults was conducted, examining the current literature on features, clinical scores, complications, magnetic resonance image (MRI) and histological outcomes, rehabilitation and cost-effectiveness. A literature review was carried out in the main medical databases to evaluate the several studies concerning ACI treatment of large-sized and full-thickness knee cartilage defects in young adults. ACI technique has been shown to relieve symptoms and improve functional assessment in large-sized (>4 cm(2)) and full-thickness knee articular cartilage defect of young adults in short- and medium-term follow-up. Besides, low level of evidence demonstrated its efficiency and durability at long-term follow-up after implantation. Furthermore, MRI and histological evaluations provided the evidence that graft can return back to the previous nearly normal cartilage via ACI techniques. Clinical outcomes tend to be similar in different ACI techniques, but with simplified procedure, low complication rate and better graft quality in the third-generation ACI technique. ACI based on the experience of cell-based therapy, with the high potential to regenerate hyaline-like tissue, represents clinical development in treatment of large-sized and full-thickness knee cartilage defects. IV.

  20. Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients

    Science.gov (United States)

    Komnik, Igor; David, Sina; Weiss, Stefan; Potthast, Wolfgang

    2016-01-01

    After knee arthroplasty (KA) surgery, patients experience abnormal kinematics and kinetics during numerous activities of daily living. Biomechanical investigations have focused primarily on level walking, whereas walking on sloped surfaces, which is stated to affect knee kinematics and kinetics considerably, has been neglected to this day. This study aimed to analyze over-ground walking on level and sloped surfaces with a special focus on transverse and frontal plane knee kinematics and kinetics in patients with KA. A three-dimensional (3D) motion analysis was performed by means of optoelectronic stereophogrammetry 1.8 ± 0.4 years following total knee arthroplasty (TKA) and unicompartmental arthroplasty surgery (UKA). AnyBody™ Modeling System was used to conduct inverse dynamics. The TKA group negotiated the decline walking task with reduced peak knee internal rotation angles compared with a healthy control group (CG). First-peak knee adduction moments were diminished by 27% (TKA group) and 22% (UKA group) compared with the CG during decline walking. No significant differences were detected between the TKA and UKA groups, regardless of the locomotion task. Decline walking exposed apparently more abnormal knee frontal and transverse plane adjustments in KA patients than level walking compared with the CG. Hence, walking on sloped surfaces should be included in further motion analysis studies investigating KA patients in order to detect potential deficits that might be not obvious during level walking. PMID:28002437

  1. Psychopharmacologic treatment and blood transfusion in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Gylvin, Silas Hinsch; Jørgensen, Christoffer Calov; Fink-Jensen, Anders

    2017-01-01

    BACKGROUND: Selective serotonin reuptake inhibitors (SSRIs) and other psychotropics are receiving increasing attention due to reports on inhibition of thrombocyte function and an increased bleeding risk in surgical settings. Studies in total hip and total knee arthroplasty (THA and TKA...

  2. KNEE-JOINT LOADING IN KNEE OSTEOARTHRITIS: INFLUENCE OF ABDOMINAL AND THIGH FAT

    Science.gov (United States)

    Messier, Stephen P.; Beavers, Daniel P.; Loeser, Richard F.; Carr, J. Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J.; Hunter, David J.; DeVita, Paul

    2014-01-01

    Purpose Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee-joint loads in older overweight and obese adults with knee osteoarthritis (OA). Methods Fat depots were quantified using computed tomography and total lean and fat mass determined with dual energy x-ray absorptiometry in 176 adults (age = 66.3 yr., BMI = 33.5 kg·m−2) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Results Higher total body mass was significantly associated (p ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (p knee extensor moments (p = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (p = 0.0001), shear (p knee extension moment (p = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (p = 0.002). A regression model that included total thigh and total abdominal fat found both were significantly associated with knee compressive and shear forces (p ≤ 0.04). Thigh fat was associated with the knee abduction (p = 0.03) and knee extension moment (p = 0.02). Conclusions Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA. PMID:25133996

  3. Metal hypersensitivity after knee arthroplasty: fact or fiction?

    Science.gov (United States)

    Innocenti, Massimo; Vieri, Berti; Melani, Tommaso; Paoli, Tommaso; Carulli, Christian

    2017-06-07

    Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. Hypersensitivity to metals has not to be nowadays considered a "fiction", but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the

  4. A multimodality regimen for deep venous thrombosis prophylaxis in total knee arthroplasty.

    Science.gov (United States)

    Reitman, Richard D; Emerson, Roger H; Higgins, Linda L; Tarbox, Tiffera R

    2003-02-01

    Data indicate that deep venous thrombosis (DVT) occurs at the time of knee arthroplasty. Nevertheless, literature concerning DVT prophylaxis has only recently addressed this contention. This prospective study evaluated the efficacy of a perioperative prophylactic regimen. Between January 1996 and June 2001, 1,308 knees (964 surgeries) underwent total knee arthroplasty. Patients were treated routinely with intraoperative heparin (1000 units intravenous push before inflation of the tourniquet and 500 units at deflation), hypotensive epidural anesthesia (MAP 70-90), external pneumatic compression boots, and aspirin (325 mg, PO, BID for 6 weeks). Duplex venous ultrasonography was performed before discharge. DVT was detected in 4% of cases (1% proximal and 3% distal). Bleeding complications occurred in 1%, and perioperative medical complications occurred in 12%. Copyright 2003, Elsevier Science (USA). All rights reserved.

  5. Patient pain and blood management in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, Bregje J.W.

    2014-01-01

    What is already known on this topic: Local infiltration analgesia in combination with a multimodal pain approach helps for adequate postoperative pain control. Blood saving alternatives should be implemented in the process of primary total hip and knee arthroplasties. The endpoint in patient

  6. Predicted osteotomy planes are accurate when using patient-specific instrumentation for total knee arthroplasty in cadavers: a descriptive analysis.

    Science.gov (United States)

    Kievit, A J; Dobbe, J G G; Streekstra, G J; Blankevoort, L; Schafroth, M U

    2018-06-01

    Malalignment of implants is a major source of failure during total knee arthroplasty. To achieve more accurate 3D planning and execution of the osteotomy cuts during surgery, the Signature (Biomet, Warsaw) patient-specific instrumentation (PSI) was used to produce pin guides for the positioning of the osteotomy blocks by means of computer-aided manufacture based on CT scan images. The research question of this study is: what is the transfer accuracy of osteotomy planes predicted by the Signature PSI system for preoperative 3D planning and intraoperative block-guided pin placement to perform total knee arthroplasty procedures? The transfer accuracy achieved by using the Signature PSI system was evaluated by comparing the osteotomy planes predicted preoperatively with the osteotomy planes seen intraoperatively in human cadaveric legs. Outcomes were measured in terms of translational and rotational errors (varus, valgus, flexion, extension and axial rotation) for both tibia and femur osteotomies. Average translational errors between the osteotomy planes predicted using the Signature system and the actual osteotomy planes achieved was 0.8 mm (± 0.5 mm) for the tibia and 0.7 mm (± 4.0 mm) for the femur. Average rotational errors in relation to predicted and achieved osteotomy planes were 0.1° (± 1.2°) of varus and 0.4° (± 1.7°) of anterior slope (extension) for the tibia, and 2.8° (± 2.0°) of varus and 0.9° (± 2.7°) of flexion and 1.4° (± 2.2°) of external rotation for the femur. The similarity between osteotomy planes predicted using the Signature system and osteotomy planes actually achieved was excellent for the tibia although some discrepancies were seen for the femur. The use of 3D system techniques in TKA surgery can provide accurate intraoperative guidance, especially for patients with deformed bone, tailored to individual patients and ensure better placement of the implant.

  7. Excellent Survival and Good Outcomes at 15 Years Using the Press-Fit Condylar Sigma Total Knee Arthroplasty.

    Science.gov (United States)

    Oliver, William M; Arthur, Calum H C; Wood, Alexander M; Clayton, Robert A E; Brenkel, Ivan J; Walmsley, Philip

    2018-03-27

    We report 15-year survival, clinical, and radiographic follow-up data for the Press-Fit Condylar Sigma total knee arthroplasty. Between October 1998 and October 1999, 235 consecutive TKAs were performed in 203 patients. Patients were reviewed at a specialist nurse-led clinic before surgery and at 5, 8-10, and 15 years postoperatively. Clinical outcomes, including Knee Society Score, were recorded prospectively at each clinic visit, and radiographs were obtained. Of our initial cohort, 99 patients (118 knees) were alive at 15 years, and 31 patients (34 knees) were lost to follow-up. Thirteen knees (5.5%) were revised; 5 (2.1%) for infection, 7 (3%) for instability, and 1 (0.4%) for aseptic loosening. Cumulative survival with the end point of revision for any reason was 92.3% at 15 years and with revision for aseptic failure as the end point was 94.4%. The mean Knee Society Score knee score was 77.4 (33-99) at 15 years, compared with 31.7 (2-62) preoperatively. Of 71 surviving knees for which X-rays were available, 12 (16.9%) had radiolucent lines and 1 (1.4%) demonstrated clear radiographic evidence of loosening. The Press-Fit Condylar Sigma total knee arthroplasty represents a durable, effective option for patients undergoing knee arthroplasty, with excellent survival and good clinical and radiographic outcomes at 15 years. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Women with knee osteoarthritis have more pain and poorer function than men, but similar physical activity prior to total knee replacement

    Directory of Open Access Journals (Sweden)

    Tonelli Shalome M

    2011-11-01

    Full Text Available Abstract Background Osteoarthritis of the knee is a major clinical problem affecting a greater proportion of women than men. Women generally report higher pain intensity at rest and greater perceived functional deficits than men. Women also perform worse than men on function measures such as the 6-minute walk and timed up and go tests. Differences in pain sensitivity, pain during function, psychosocial variables, and physical activity levels are unclear. Further the ability of various biopsychosocial variables to explain physical activity, function and pain is unknown. Methods This study examined differences in pain, pain sensitivity, function, psychosocial variables, and physical activity between women and men with knee osteoarthritis (N = 208 immediately prior to total knee arthroplasty. We assessed: (1 pain using self-report measures and a numerical rating scale at rest and during functional tasks, (2 pain sensitivity using quantitative sensory measures, (3 function with self-report measures and specific function tasks (timed walk, maximal active flexion and extension, (4 psychosocial measures (depression, anxiety, catastrophizing, and social support, and (5 physical activity using accelerometry. The ability of these mixed variables to explain physical activity, function and pain was assessed using regression analysis. Results Our findings showed significant differences on pain intensity, pain sensitivity, and function tasks, but not on psychosocial measures or physical activity. Women had significantly worse pain and more impaired function than men. Their levels of depression, anxiety, pain catastrophizing, social support, and physical activity, however, did not differ significantly. Factors explaining differences in (1 pain during movement (during gait speed test were pain at rest, knee extension, state anxiety, and pressure pain threshold; (2 function (gait speed test were sex, age, knee extension, knee flexion opioid medications, pain

  9. Late group-based rehabilitation has no advantages compared with supervised home-exercises after total knee arthroplasty

    DEFF Research Database (Denmark)

    Madsen, Majbritt; Larsen, Kristian; Madsen, Inger Kirkegård

    2013-01-01

    This study aimed to test whether group-based rehabilitation focusing on strength training, education and self-management is more effective than individual, supervised home-training after fast-track total knee arthroplasty (TKA).......This study aimed to test whether group-based rehabilitation focusing on strength training, education and self-management is more effective than individual, supervised home-training after fast-track total knee arthroplasty (TKA)....

  10. Functional angiography of arteries near the knee joint: Consequences for stent implantation. Funktionsangiographie der kniegelenknahen Arterien: Konsequenzen fuer die Stentimplantation

    Energy Technology Data Exchange (ETDEWEB)

    Zocholl, G; Zapf, S; Schild, H; Thelen, M [Mainz Univ. (Germany, F.R.). Inst. fuer Klinische Strahlenkunde

    1990-12-01

    Angiographic studies of the arteries adjoining the knee in 25 patients show extensive kinking and stenoses of the popliteal artery and less frequently of the distal femoral artery during flexion of the knee joint. This is due to the loss of elasticity with increasing age forcing the vessel into a tortuous course during shortening of the pathway of the popliteal artery with knee flexion. Independent of the principle of the different stents available they probably will not increase the contractility of the stented vessel in the longitudinal axis. It is to expect that after implantation of stents into the original artery kinking will occur predominantly in the original segments of the vessel and at the transitions to the stented segments leading to intimal damage by shear forces thus propagating local progress of atherosclerosis. (orig.).

  11. Custom total knee replacement in a dog with femoral condylar bone loss.

    Science.gov (United States)

    Liska, William D; Marcellin-Little, Denis J; Eskelinen, Esa V; Sidebotham, Christopher G; Harrysson, Ola L A; Hielm-Björkman, Anna K

    2007-06-01

    To report surgical planning, technique, and outcome of custom total knee replacement (TKR) performed to manage a medial femoral condylar nonunion in a dog. Clinical case report. A 3-year-old, 20 kg Karelian Bear Hound. Computed tomographic scan of the left pelvic limb was used to build a stereolithography model of the distal portion of the femur. The model was used to create a custom augment to replace the missing medial femoral condyle and a custom stem for intramedullary condylar cemented fixation. The augment and stem were adapted to femoral and tibial components already available. The model was used to rehearse the surgery and then the custom prosthesis was implanted. Weight bearing returned 8 hours after surgery and improved thereafter. Joint alignment was normal and prosthetic joint motion was 60-165 degrees postoperatively. The dog resumed moose hunting 3 months after surgery. Peak vertical force and impulse of the operated limb measured 17 months after surgery were 65% and 47% of the normal, contralateral limb. Based on short-term follow-up, cemented canine TKR was successfully achieved for management of a severely abnormal stifle joint. With further refinement and development of commercially available prostheses, TKR should be possible for canine patients.

  12. Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern.

    Science.gov (United States)

    Thomas, Peter; von der Helm, Christine; Schopf, Christoph; Mazoochian, Farhad; Frommelt, Lars; Gollwitzer, Hans; Schneider, Josef; Flaig, Michael; Krenn, Veit; Thomas, Benjamin; Summer, Burkhard

    2015-01-01

    We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR): patch test (PT), lymphocyte transformation test (LTT), histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils), and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFNγ, TNFα, IL1-β, IL-2, IL-6, IL-8, IL-10, IL17, and TGFβ). We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions; 9 with only LTT reactivity). Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane) tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFNγ expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies.

  13. Patients with Intolerance Reactions to Total Knee Replacement: Combined Assessment of Allergy Diagnostics, Periprosthetic Histology, and Peri-implant Cytokine Expression Pattern

    Directory of Open Access Journals (Sweden)

    Peter Thomas

    2015-01-01

    Full Text Available We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR: patch test (PT, lymphocyte transformation test (LTT, histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils, and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFNγ, TNFα, IL1-β, IL-2, IL-6, IL-8, IL-10, IL17, and TGFβ. We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions; 9 with only LTT reactivity. Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFNγ expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies.

  14. A Computer Navigation System Analysis of the Accuracy of the Extramedullary (Tibial Alignment Technique in Total Knee Arthroplasty (TKA

    Directory of Open Access Journals (Sweden)

    EK Chee

    2010-07-01

    Full Text Available In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.

  15. Sciatic nerve block causing heel ulcer after total knee replacement in 36 patients.

    Science.gov (United States)

    Todkar, Manoj

    2005-12-01

    Femoral and sciatic nerve blocks are often used for postoperative analgesia following total knee replacement surgery. In this report, we focus on cases of heel ulcers which occurred following the implementation of peripheral nerve block in concert with knee replacement surgery. In some instances, heel ulcers have resulted in delayed rehabilitation and prolonged hospital stays in this group of patients, which makes this phenomenon a potential burden on the healthcare system. Pressure points in the foot should be protected after the implementation of nerve blocks to prevent pressure sores. An awareness of this unusual complication related to knee replacement surgery is necessary to prevent its occurrence and avoid delays in patient rehabilitation and recovery.

  16. A 5 year prospective study of patient-relevant outcomes after total knee replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A-K; Toksvig-Larsen, S; Roos, E M

    2008-01-01

    men, mean age 71 (51-86) assigned for TKR at the Department of Orthopaedics at Lund University Hospital were included in the study. The self-administered questionnaires Knee injury and Osteoarthritis Outcome Score (KOOS) and SF-36 were mailed preoperatively and 6 months, 12 months and at 5 years......OBJECTIVE: To prospectively describe self-reported outcomes up to 5 years after total knee replacement (TKR) in Osteoarthritis (OA) and to study which patient-relevant factors may predict outcomes for pain and physical function (PF). METHODS: 102 consecutive patients with knee OA, 63 women and 39...... postoperatively. RESULTS: Response rate at 5 years was 86%. At 6 months significant improvement was seen in all KOOS and SF-36 scores (P

  17. The Effect of Patellar Denervation by Circumpatellar Electrocautery on Anterior Knee Pain Following Total Knee Replacement – An Experimental Study

    Directory of Open Access Journals (Sweden)

    Balaji Zacharia

    2017-07-01

    Full Text Available ABSTRACT OBJECTIVES Anterior knee pain is a common problem in patients who have undergone TKR which causes dissatisfaction among them. There are Various methods for prevention of anterior knee pain following TKR .The  objective of this study is to determine the  effect of circumpatellar electrocautery on anterior knee pain following TKR and to compare the results with that of those patients who have undergone TKR without circumpatellar denervation. METHODS This is a cohort study conducted in Dept. of Orthopedics, Govt. Medical College, Kozhikode,kerala, 2014. Total sample size was 90.out of which 2 patients died during the study period. We lost follow up of 7 patients.  Among the remaining 81 patients 42 had undergone TKR with circumpatellar denervation using electocautery and 39 without circumpatellar denervation. They were kept under follow up. Patients were followed up postoperatively at 1 month, 3 months, 6 months and at one year. At all postoperative visits, a clinical score was determined using the Knee Society score and the clinical anterior knee pain rating system described by Waters and Bentley RESULTS There is no statistically significant difference in AKP score between both groups.There is a statistically significant difference in the knee society score at 1st month(p value <.001.  But there is no difference on further follow up visits . CONCLUSION There is no statistically significant difference between final outcome of patients who underwent patella denervation using circumpatellar electrocauterisation and those without denervation  with respect to anterior knee pain among patients who have undergone TKR.

  18. Simple geometry tribological study of osteochondral graft implantation in the knee.

    Science.gov (United States)

    Bowland, Philippa; Ingham, Eileen; Fisher, John; Jennings, Louise M

    2018-03-01

    Robust preclinical test methods involving tribological simulations are required to investigate and understand the tribological function of osteochondral repair interventions in natural knee tissues. The aim of this study was to investigate the effects of osteochondral allograft implantation on the local tribology (friction, surface damage, wear and deformation) of the tissues in the natural knee joint using a simple geometry, reciprocating pin-on-plate friction simulator. In addition, the study aimed to assess the ability of osteochondral grafts to restore a low surface damage, deformation and wear articulation when compared to the native state. A method was developed to characterise and quantify surface damage wear and deformation of the opposing cartilage-bone pin surface using a non-contacting optical profiler (Alicona Infinite Focus). Porcine 12 mm diameter cartilage-bone pins were reciprocated against bovine cartilage-bone plates that had 6 mm diameter osteochondral allografts, cartilage defects or stainless steel pins (positive controls) inserted centrally. Increased levels of surface damage with changes in geometry were not associated with significant increases in the coefficient of dynamic friction. Significant damage to the opposing cartilage surface was observed in the positive control groups. Cartilage damage, deformation and wear (as measured by change in geometry) in the xenograft (2.4 mm 3 ) and cartilage defect (0.99 mm 3 ) groups were low and not significantly different (p > 0.05) compared to the negative control in either group. The study demonstrated the potential of osteochondral grafts to restore the congruent articular surface and biphasic tribology of the natural joint. An optical method has been developed to characterise cartilage wear, damage and deformation that can be applied to the tribological assessment of osteochondral grafts in a whole natural knee joint simulation model.

  19. Evaluation of the effects of a physiotherapy program on quality of life in females after unilateral total knee arthroplasty: a prospective study.

    Science.gov (United States)

    Hudáková, Zuzana; Zięba, Halina Romualda; Lizis, Paweł; Dvořáková, Vlasta; Cetlová, Lada; Friediger, Teresa; Kobza, Wojciech

    2016-05-01

    [Purpose] Osteoarthritis is a chronic and degenerative joint disease and is considered to be one of the most common musculoskeletal disorders. This study evaluated the differences in the quality of life of females treated with supervised physiotherapy and a standardized home program after unilateral total knee arthroplasty. [Subjects and Methods] From January 2012 to May 2015, a total of 40 females were examined at the Central Military Hospital in Ruzomberk, Slovakia. Quality of life was assessed with the Short Form-36. Quality of life and intensity of pain after normal daily activity, according to the visual analog scale, were assessed before total knee arthroplasty, immediately after physiotherapy, 3 months after total knee arthroplasty, and 6 months after total knee arthroplasty. [Results] We found statistically significant improvement of the quality of life results and a decreased intensity of pain at each time point compared with before total knee arthroplasty. [Conclusions] The results of this study provide further evidence indicating that patients who undergo total knee arthroplasty for primary osteoarthritis of the knee can achieve a significant improvement in the quality of life by using supervised physiotherapy compared with a standardized home program.

  20. Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study.

    Science.gov (United States)

    Leuridan, Steven; Goossens, Quentin; Vander Sloten, Tom; De Landsheer, Koen; Delport, Hendrik; Pastrav, Leonard; Denis, Kathleen; Desmet, Wim; Vander Sloten, Jos

    2017-11-01

    The preoperative diagnosis of loosening of cemented tibial knee implants is challenging. This feasibility study explored the basic potential of a vibration-based method as an alternative diagnostic technique to assess the fixation state of a cemented tibia implant and establish the method's sensitivity limits. A combined in vitro and in silico approach was pursued. Several loosening cases were simulated. The largest changes in the vibrational behavior were obtained in the frequency range above 1500 Hz. The vibrational behavior was described with two features; the frequency response function and the power spectral density band power. Using both features, all experimentally simulated loosening cases could clearly be distinguished from the fully cemented cases. By complementing the experimental work with an in silico study, it was shown that loosening of approximately 14% of the implant surface on the lateral and medial side was detectable with a vibration-based method. Proximal lateral and medial locations on the tibia or locations toward the edge of the implant surface measured in the longitudinal direction were the most sensitive measurement and excitation locations to assess implant fixation. These results contribute to the development of vibration-based methods as an alternative follow-up method to detect loosened tibia implants. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Oral Tranexamic Acid Reduces Transfusions in Total Knee Arthroplasty.

    Science.gov (United States)

    Perreault, Roger E; Fournier, Christine A; Mattingly, David A; Junghans, Richard P; Talmo, Carl T

    2017-10-01

    Tranexamic acid (TXA) reduces intraoperative blood loss and transfusions in patients undergoing total knee arthroplasty. Although numerous studies demonstrate the efficacy of intravenous and topical TXA in these patients, few demonstrate the effectiveness and appropriate dosing recommendations of oral formulations. A retrospective cohort study was performed to evaluate differences in transfusion requirements in patients undergoing primary unilateral total knee arthroplasty with either no TXA (n = 866), a single-dose of oral TXA (n = 157), or both preoperative and postoperative oral TXA (n = 1049). Secondary outcomes included postoperative hemoglobin drop, total units transfused, length of stay, drain output, and cell salvage volume. Transfusion rates decreased from 15.4% in the no-oral tranexamic acid (OTA) group to 9.6% in the single-dose OTA group (P < .001) and 7% in the 2-dose group (P < .001), with no difference in transfusion rates between the single- and 2-dose groups (P = .390). In addition, postoperative hemoglobin drop was reduced from 4.2 g/dL in the no-OTA group to 3.5 g/dL in the single-dose group (P < .01) and to 3.4 g/dL in the 2-dose group (P < .01), without a difference between the single- and 2-dose groups (P = .233). OTA reduces transfusions, with greater ease of administration and improved cost-effectiveness relative to other forms of delivery. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. What Is the Impact of Smoking on Revision Total Knee Arthroplasty?

    Science.gov (United States)

    Bedard, Nicholas A; Dowdle, S Blake; Wilkinson, Brandon G; Duchman, Kyle R; Gao, Yubo; Callaghan, John J

    2018-07-01

    There is a paucity of literature evaluating the impact of smoking on revision arthroplasty procedures. The purpose of this study was to identify the effect of smoking on complications after revision total knee arthroplasty (rTKA). We queried the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database to identify patients who underwent rTKA between 2006 and 2014. Patients were divided into current smokers and nonsmokers according to the NSQIP definitions. Each cohort was compared in terms of demographic data, preoperative comorbidities, and operative time. Infection end points were created from composite surgical site infection variables defined by the NSQIP database. Multivariate logistic regression analysis was utilized to adjust for confounding variables and calculate adjusted odds ratios (ORs) and associated 95% confidence intervals (95% CIs). In total, 8776 patients underwent rTKA. Of these patients, 11.6% were current smokers. Univariate analyses demonstrated that smokers had a higher rate of any wound complication (3.8% vs 1.8%, P < .0001), deep infection (2.5% vs 1.0%, P < .0001), pneumonia (1.3% vs 0.4%, P < .0001), and reoperation (5.0% vs 3.1%, P = .001) compared to nonsmokers undergoing revision total knee arthroplasty. Multivariate analysis identified current smokers as being at a significantly increased risk of any wound complication (OR 2.1; 95% CI 1.4-3.1) and deep infection (OR 2.1, 95% CI 1.2-3.6) after rTKA. This study demonstrates that smoking significantly increases the risk of infection, wound complications, and reoperation after rTKA. The results are even more magnified for revision procedures compared to published effects of smoking on primary total knee arthroplasty complications. Further research is needed regarding the impact of smoking cessation on mitigation of these observed risks. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Antibiotic-impregnated articulating cement spacer for infected total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Parag Garg

    2011-01-01

    Full Text Available Background : Standard treatment of chronic infected total knee arthroplasty (TKA is a two-stage revision, the first step being placement of an antibiotic-impregnated cement spacer. Here we describe the results of a new technique (modification of the Goldstien′s technique for intraoperative manufacture of a customized articulating spacer at minimal cost and with relatively good conformity and longevity. Materials and Methods : Thirty-six infected knees underwent this procedure from June 2002 to May 2007. The technique consists of using the freshened femur and tibia interface as molds wrapped in a tin foil for manufacturing the two components of the spacer with antibiotic-impregnated methyl methycrylate cement. We used the spacer and the femoral component of the trial set of a TKA system to mold them to perfect articulation. We also reinforced the spacer with a K-wire scaffold to prevent fracture of the cement mantle in the last 21 cases. Results : All 36 knees showed excellent results in terms of infection control, mobility, and stability. There was significant improvement in the WOMAC and Knee Society Scores (20 and 39 points respectively. There were two fractures of the spacers in the initial 15 cases that did not have K-wire scaffolding but none in the last 21 that had reinforcement. Conclusion : This technique provides a more conforming spacer, with good range of motion and stability. The reinforcement helps in preventing the fracture of the cement mantle and is cost effective.

  4. Decreasing medical complications for total knee arthroplasty: Effect of Critical Pathways on Outcomes

    Directory of Open Access Journals (Sweden)

    Solomon Daniel H

    2010-07-01

    Full Text Available Abstract Background Studies on critical pathway use have demonstrated decreased length of stay and cost without compromise in quality of care. However, pathway effectiveness is difficult to determine given methodological flaws, such as small or single center cohorts. We studied the effect of critical pathways on total knee replacement outcomes in a large population-based study. Methods We identified hospitals in four US states that performed total knee replacements. We sent a questionnaire to surgical administrators in these hospitals including items about critical pathway use and hospital characteristics potentially related to outcomes. Patient data were obtained from Medicare claims, including demographics, comorbidities, 90-day postoperative complications and length of hospital stay. The principal outcome measure was the risk of having one or more postoperative complications. Results Two hundred ninety five hospitals (73% responded to the questionnaire, with 201 reporting the use of critical pathways. 9,157 Medicare beneficiaries underwent TKR in these hospitals with a mean age of 74 years (± 5.8. After adjusting for both patient and hospital related variables, patients in hospitals with pathways were 32% less likely to have a postoperative complication compared to patients in hospitals without pathways (OR 0.68, 95% CI 0.50-0.92. Patients managed on a critical pathway had an average length of stay 0.5 days (95% CI 0.3-0.6 shorter than patients not managed on a pathway. Conclusion Medicare patients undergoing total knee replacement surgery in hospitals that used critical pathways had fewer postoperative complications than patients in hospitals without pathways, even after adjusting for patient and hospital related factors. This study has helped to establish that critical pathway use is associated with lower rates of postoperative mortality and complications following total knee replacement after adjusting for measured variables.

  5. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  6. Effect of pre-operative neuromuscular training on functional outcome after total knee replacement

    DEFF Research Database (Denmark)

    Huber, Erika O; de Bie, Rob A; Roos, Ewa M.

    2013-01-01

    Total Knee Replacement (TKR) is the standard treatment for patients with severe knee osteoarthritis (OA). Significant improvement in pain and function are seen after TKR and approximately 80% of patients are very satisfied with the outcome. Functional status prior to TKR is a major predictor...... of outcome after the intervention. Thus, improving functional status prior to surgery through exercise may improve after surgery outcome. However, results from several previous trials testing the concept have been inconclusive after surgery....

  7. Recovery after total intravenous general anaesthesia or spinal anaesthesia for total knee arthroplasty

    DEFF Research Database (Denmark)

    Harsten, A; Kehlet, H; Toksvig-Larsen, S

    2013-01-01

    BACKGROUND: /st>This study was undertaken to compare the effects of general anaesthesia (GA) and spinal anaesthesia (SA) on the need for postoperative hospitalization and early postoperative comfort in patients undergoing fast-track total knee arthroplasty (TKA). METHODS: /st>One hundred and twenty....... Secondary outcome parameters included actual time of discharge, postoperative pain, intraoperative blood loss, length of stay in the Post Anaesthesia Care Unit, dizziness, postoperative nausea and vomiting, need for urinary catheterization and subject satisfaction. RESULTS: /st>GA resulted in shorter LOS...

  8. Systematic Analysis of Painful Total Knee Prosthesis, a Diagnostic Algorithm

    Directory of Open Access Journals (Sweden)

    Oliver Djahani

    2013-12-01

    Full Text Available   Remaining pain after total knee arthroplasty (TKA is a common observation in about 20% of postoperative patients; where in about 60% of these knees require early revision surgery within five years. Obvious causes of this pain could be identified simply with clinical examinations and standard radiographs. However, unexplained painful TKA still remains a challenge for the surgeon. The management should include a multidisciplinary approach to the patient`s pain as well as addressing the underlying etiology. There are a number of extrinsic (tendinopathy, hip, ankle, spine, CRPS and so on and intrinsic (infection, instability, malalignment, wear and so on causes of painful knee replacement. On average, diagnosis takes more than 12 months and patients become very dissatisfied and some of them even acquire psychological problems. Hence, a systematic diagnostic algorithm might be helpful. This review article aims to act as a guide to the evaluation of patients with painful TKA described in 10 different steps. Furthermore, the preliminary results of a series of 100 consecutive cases will be discussed. Revision surgery was performed only in those cases with clear failure mechanism.

  9. Lactobacillus as a rare cause of an infected total knee replacement: a case report

    Science.gov (United States)

    2009-01-01

    Introduction We report a rare case of an infected revision total knee replacement as a result of a Lactobacillus species infection. Lactobacillus infections have been associated with prolonged broad-spectrum antibiotic use. This can have implications in revision surgery, especially when patients have been on previous long-term suppressive antibiotic therapy. Case presentation An 81-year-old British man with a previous history of complex revision knee arthroplasty for infection presented with a hot, swollen knee joint. He had previously been on long-term suppressive antibiotic therapy. Aspiration of the knee joint yielded a culture of Lactobacillus species. Conclusion In patients undergoing revision joint arthroplasty, especially for previous infection, the presence of common and uncommon bacterial species must be excluded and eradicated before further surgical intervention. PMID:19830207

  10. Safety and Feasibility of a KineSpring Knee System for the Treatment of Osteoarthritis: A Case Series

    Directory of Open Access Journals (Sweden)

    David A. Hayes

    2015-01-01

    Full Text Available The treatment gap between conservative management and total knee arthroplasty may leave patients with moderate cases of knee osteoarthritis (OA without an ideal treatment option. The KineSpring® Knee Implant System may be a viable treatment option to fill the treatment gap for patients with knee OA who are not willing or inappropriate candidates for total knee arthroplasty, yet do not demonstrate relief with conservative treatments. This current paper reports a series of patients who received the KineSpring System and were followed for five years. Twelve patients were included in the case series. All 12 patients were diagnosed with symptomatic OA of the medial compartment of the knee. Pain and functional problems associated with OA improved with treatment using the KineSpring System. Furthermore, these improvements were seen over the course of five years. The findings of this study show the KineSpring System as a promising intervention for early-onset OA and warrant further investigation regarding its effectiveness.

  11. No Exacerbation of Knee Joint Pain and Effusion Following Preoperative Progressive Resistance Training in Patients Scheduled for Total Knee Arthroplasty: Secondary Analyses From a Randomized Controlled Trial.

    Science.gov (United States)

    Skoffer, Birgit; Dalgas, Ulrik; Maribo, Thomas; Søballe, Kjeld; Mechlenburg, Inger

    2017-11-09

    Preoperative progressive resistance training (PRT) is controversial in patients scheduled for total knee arthroplasty (TKA), because of the concern that it may exacerbate knee joint pain and effusion. To examine whether preoperative PRT initiated 5 weeks prior to TKA would exacerbate pain and knee effusion, and would allow a progressively increased training load throughout the training period that would subsequently increase muscle strength. Secondary analyses from a randomized controlled trial. University Hospital and a Regional Hospital. A total of 30 patients who were scheduled for TKA due to osteoarthritis and assigned as the intervention group. Patients underwent unilateral PRT (3 sessions per week). Exercise loading was 12 repetitions maximum (RM) with progression toward 8 RM. The training program consisted of 6 exercises performed unilaterally. Before and after each training session, knee joint pain was rated on an 11-point scale, effusion was assessed by measuring the knee joint circumference, and training load was recorded. The first and last training sessions were initiated by 1 RM testing of unilateral leg press, unilateral knee extension, and unilateral knee flexion. The median pain change score from before to after each training session was 0 at all training sessions. The average increase in knee joint effusion across the 12 training sessions was a mean 0.16 cm ± 0.23 cm. No consistent increase in knee joint effusion after training sessions during the training period was found (P = .21). Training load generally increased, and maximal muscle strength improved as follows: unilateral leg press: 18% ± 30% (P = .03); unilateral knee extension: 81% ± 156% (P knee flexion: 53% ± 57% (P knee joint pain and effusion, despite a substantial progression in loading and increased muscle strength. Concerns for side effects such as pain and effusion after PRT seem unfounded. To be determined. Copyright © 2017. Published by Elsevier Inc.

  12. Predictors of revision, prosthetic joint infection and mortality following total hip or total knee arthroplasty in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Cordtz, Rene Lindholm; Zobbe, Kristian; Højgaard, Pil

    2018-01-01

    OBJECTIVES: To investigate predictors of 10-year risk of revision and 1-year risk of prosthetic joint infection (PJI) and death following total hip/total knee arthroplasty (THA/TKA) in (1) patients with rheumatoid arthritis (RA) compared with patients with osteoarthritis (OA); and (2) patients...

  13. Effect of medial–lateral malpositioning of the femoral component in total knee arthroplasty on anterior knee pain at greater than 8 years of follow-up

    NARCIS (Netherlands)

    van de Groes, S.A.W.; Koëter, S.; De Waal Malefijt, M.C.; Verdonschot, Nicolaas Jacobus Joseph

    2014-01-01

    Background The trochlea is often medialized after total knee arthroplasty (TKA) resulting in abnormal patellar tracking, which may lead to anterior knee pain. However, due to the difference in shape of the natural trochlea and the patellar groove of the femoral component, a medialization of the

  14. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up

    Directory of Open Access Journals (Sweden)

    Yamanaka Hajime

    2012-02-01

    Full Text Available Abstract Background Total knee arthroplasty (TKA is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA. Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE, is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  15. Negative emotions affect postoperative scores for evaluating functional knee recovery and quality of life after total knee replacement

    Directory of Open Access Journals (Sweden)

    A. Qi

    2016-01-01

    Full Text Available This study aimed to determine whether psychological factors affect health-related quality of life (HRQL and recovery of knee function in total knee replacement (TKR patients. A total of 119 TKR patients (male: 38; female: 81 completed the Beck Anxiety Inventory (BAI, Beck Depression Inventory (BDI, State Trait Anxiety Inventory (STAI, Eysenck Personality Questionnaire-revised (EPQR-S, Knee Society Score (KSS, and HRQL (SF-36. At 1 and 6 months after surgery, anxiety, depression, and KSS scores in TKR patients were significantly better compared with those preoperatively (P<0.05. SF-36 scores at the sixth month after surgery were significantly improved compared with preoperative scores (P<0.001. Preoperative Physical Component Summary Scale (PCS and Mental Component Summary Scale (MCS scores were negatively associated with extraversion (E score (B=-0.986 and -0.967, respectively, both P<0.05. Postoperative PCS and State Anxiety Inventory (SAI scores were negatively associated with neuroticism (N score; B=-0.137 and -0.991, respectively, both P<0.05. Postoperative MCS, SAI, Trait Anxiety Inventory (TAI, and BAI scores were also negatively associated with the N score (B=-0.367, -0.107, -0.281, and -0.851, respectively, all P<0.05. The KSS function score at the sixth month after surgery was negatively associated with TAI and N scores (B=-0.315 and -0.532, respectively, both P<0.05, but positively associated with the E score (B=0.215, P<0.05. The postoperative KSS joint score was positively associated with postoperative PCS (B=0.356, P<0.05. In conclusion, for TKR patients, the scores used for evaluating recovery of knee function and HRQL after 6 months are inversely associated with the presence of negative emotions.

  16. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  17. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    OpenAIRE

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization ...

  18. Reliability of the 6-min walk test after total knee arthroplasty

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Kehlet, Henrik; Bandholm, Thomas

    2013-01-01

    PURPOSE: The 6-min walk test is a simple clinical outcome measure, which has been used frequently to assess functional performance in many different patient groups, including patients with total knee arthroplasty (TKA). The 6-min walk test measures the maximal distance a subject is able to walk i...

  19. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    OpenAIRE

    Hirschmann, Michael T; Konala, Praveen; Iranpour, Farhad; Kerner, Anna; Rasch, Helmut; Friederich, Niklaus F

    2011-01-01

    Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA). Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization sch...

  20. Does the grading of chondromalacia patellae influence anterior knee pain following total knee arthroplasty without patellar resurfacing?

    Science.gov (United States)

    Zha, Guo-Chun; Feng, Shuo; Chen, Xiang-Yang; Guo, Kai-Jin

    2018-03-01

    The influence of chondromalacia patellae (CMP) on post-operative anterior knee pain (AKP) following total knee arthroplasty (TKA) remains controversial, and few studies have focused on the relationship between them. The purpose of this study was to determine whether different CMP grades affect the incidence of AKP after TKA without patellar resurfacing. We performed a retrospective analysis of prospectively collected data on 290 TKAs with the use of the low contact stress mobile-bearing prosthesis, without patellar resurfacing in 290 patients from February 2009 to January 2013. Patients were assessed by the Outerbridge classification for CMP, visual analog scale for AKP, the Knee Society clinical scoring system of knee score (KS), function score (FS), the patellar score (PS) for clinical function, and patients' satisfaction. The intra-operative grading of CMP: grade I in 30 patients, grade II in 68 patients, grade III in 97 patients, and grade IV in 95 patients. The incidence of AKP at 36-month follow-up was 10.3% (30/290). No statistical difference was detected among the different CMP grades in terms of the incidence of AKP (p = 0.995), patients' satisfaction (p = 0.832), KS (p = 0.228), FS (p = 0.713), and PS (p = 0.119) at 36-month follow-up. The findings may suggest no relevant influence of CMP grading on the incidence of AKP after TKA without patellar resurfacing.

  1. Individualised distal femoral cut improves femoral component placement and limb alignment during total knee replacement in knees with moderate and severe varus deformity.

    Science.gov (United States)

    Palanisami, Dhanasekararaja; Iyyampillai, Geethan; Shanmugam, Sivaraj; Natesan, Rajkumar; S, Rajasekaran

    2016-10-01

    Our aim was to determine the variation in valgus correction angle and the influence of individualised distal femoral cut on femoral component placement and limb alignment during total knee replacement (TKR) in knees with varus deformity. The study was done prospectively in two stages. In the first stage, the valgus correction angle (VCA) was calculated in long-limb radiographs of 227 patients and correlated with pre-operative parameters of femoral bowing, neck-shaft angle and hip-knee-ankle angle. In the second part comprising of 240 knees with varus deformity, 140 (group 1) had the distal femoral cut individualised according to the calculated VCA, while the remaining 100 knees (group 1) were operated with a fixed distal femoral cut of 5°. The outcome of surgery was studied by grouping the knees as varus 15°. Of the 227 limbs analysed in stage I, 70 knees (31 %) had a VCA angle outside 5-7°. Coronal bowing (p shaft angle (p alignment when VCA was individualised in the groups of knees with varus 10-15° (p 0.002) and varus >15° (p 0.002). Valgus correction angle is highly variable and is influenced by femoral bowing, neck-shaft angle and pre-operative deformity. Individualisation of VCA is preferable in patients with moderate and severe varus deformity. Level 2.

  2. Relationship between Improvements in Physical Measures and Patient Satisfaction in Rehabilitation after Total Knee Arthroplasty

    Science.gov (United States)

    Nazzal, Mahmoud I.; Bashaireh, Khaldoon H.; Alomari, Mahmoud A.; Nazzal, Mohammad S.; Maayah, Mikhled F.; Mesmar, Mohammad

    2012-01-01

    The aim of this study was to examine patient satisfaction with rehabilitation after total knee arthroplasty (TKA). Fifty-six patients, aged 45-77 years, were enrolled in a post-TKA comprehensive therapy program focusing on knee strengthening and functional activities. The program lasted 3 months and was conducted for 1 h, twice a day, 5 days per…

  3. Patellofemoral arthritis treated with resurfacing implant: Clinical outcome and complications at a minimum two-year follow-up.

    Science.gov (United States)

    Zicaro, Juan Pablo; Yacuzzi, Carlos; Astoul Bonorino, Juan; Carbo, Lisandro; Costa-Paz, Matias

    2017-12-01

    This study evaluated the clinical and radiographic outcomes of a series of patients treated with an anatomic inlay resurfacing implant, with a minimum two-year follow-up. Fifteen patients underwent patellofemoral-resurfacing procedures using a HemiCAP Wave Patellofemoral Inlay Resurfacing implant from 2010 to 2013. Clinical outcomes included: Visual Analog Scale (VAS), Lysholm score, Knee Society Score (KSS), and evaluation of Kujala, and Hospital for Special Surgery Patellofemoral score (HSS-PF). The postoperative complications were analyzed. Nineteen knees were evaluated; the average follow-up was 35.2months. Fourteen were women, with an average age of 54years. The pre-operative/postoperative clinical results presented a significant improvement: VAS 8/2.5, Lysholm 31.9/85.8, KSS 39.8/82.5, Kujala 32.1/79.3 and Hospital for Special Surgery Patellofemoral score (HSS-PF) 15.9/90.6. A total of 87% of patients were either satisfied or very satisfied with the overall outcome. There were no radiographic signs of loosening. Seven postoperative complications were recorded: two presented ongoing knee pain, one postoperative stiffness, one patellar bounce due to maltracking, two ilio-tibial band syndrome, and one tibial anterior tuberosity osteotomy nonunion. Two patients underwent a total knee arthroplasty conversion and were considered a failure. None of these complications were implant related. Patellofemoral inlay resurfacing for isolated patellofemoral arthritis was an effective and safe procedure with high levels of patient satisfaction. No mechanical implant failure was seen at a minimum two-year follow-up. This implant design appeared to be an alternative to the traditional patellofemoral prostheses. Concomitant osteochondral lesions, patellofemoral dysplasia or patellar maltracking might be poor prognostic factors for this type of implant. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model.

    Directory of Open Access Journals (Sweden)

    A C T Vrancken

    Full Text Available Since the treatment options for symptomatic total meniscectomy patients are still limited, an anatomically shaped, polycarbonate urethane (PCU, total meniscus replacement was developed. This study evaluates the in vivo performance of the implant in a goat model, with a specific focus on the implant location in the joint, geometrical integrity of the implant and the effect of the implant on synovial membrane and articular cartilage histopathological condition.The right medial meniscus of seven Saanen goats was replaced by the implant. Sham surgery (transection of the MCL, arthrotomy and MCL suturing was performed in six animals. The contralateral knee joints of both groups served as control groups. After three months follow-up the following aspects of implant performance were evaluated: implant position, implant deformation and the histopathological condition of the synovium and cartilage.Implant geometry was well maintained during the three month implantation period. No signs of PCU wear were found and the implant did not induce an inflammatory response in the knee joint. In all animals, implant fixation was compromised due to suture breakage, wear or elongation, likely causing the increase in extrusion observed in the implant group. Both the femoral cartilage and tibial cartilage in direct contact with the implant showed increased damage compared to the sham and sham-control groups.This study demonstrates that the novel, anatomically shaped PCU total meniscal replacement is biocompatible and resistant to three months of physiological loading. Failure of the fixation sutures may have increased implant mobility, which probably induced implant extrusion and potentially stimulated cartilage degeneration. Evidently, redesigning the fixation method is necessary. Future animal studies should evaluate the improved fixation method and compare implant performance to current treatment standards, such as allografts.

  5. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-02

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  6. Does circumpatellar electrocautery improve the outcome after total knee replacement?: a prospective, randomised, blinded controlled trial.

    Science.gov (United States)

    Baliga, S; McNair, C J; Barnett, K J; MacLeod, J; Humphry, R W; Finlayson, D

    2012-09-01

    The incidence of anterior knee pain following total knee replacement (TKR) is reported to be as high as 49%. The source of the pain is poorly understood but the soft tissues around the patella have been implicated. In theory circumferential electrocautery denervates the patella thereby reducing efferent pain signals. However, there is mixed evidence that this practice translates into improved outcomes. We aimed to investigate the clinical effect of intra-operative circumpatellar electrocautery in patients undergoing TKR using the LCS mobile bearing or Kinemax fixed bearing TKR. A total of 200 patients were randomised to receive either circumpatellar electrocautery (diathermy) or not (control). Patients were assessed by visual analogue scale (VAS) for anterior knee pain and Oxford knee score (OKS) pre-operatively and three months, six months and one year post-operatively. Patients and assessors were blinded. There were 91 patients in the diathermy group and 94 in the control. The mean VAS improvement at one year was 3.9 in both groups (control; -10 to 6, diathermy; -9 to 8, p electrocautery on either VAS anterior knee pain or OKS for patients undergoing LCS and Kinemax TKR.

  7. Is the posterior cruciate ligament destabilized after the tibial cut in a cruciate retaining total knee replacement? An anatomical study.

    Science.gov (United States)

    Liabaud, Barthelemy; Patrick, David A; Geller, Jeffrey A

    2013-12-01

    Cruciate retaining total knee replacement has been shown to effectively improve pain and quality of life. Successful outcomes depend on many factors, including the maintenance of a competent posterior cruciate ligament. This study sought to anatomically analyze the percentage of PCL injured during a full transverse, tibial cut, thus altering normal function. One hundred and thirty five consecutive knee MRIs taken from 2006 to 2011 were selected from a single surgeon's database for this study. Only subjects with non-arthritic knees were considered for this study; the lack of degenerative joint disease (DJD) was confirmed via a radiological report. The optimal view of the PCL's tibial attachment was observed using the sagittal view of the knee, with a T1 signal. One hundred and twenty two usable images were viewed electronically, and measurements were made using the standardized transverse cut implant guidelines. The percentage of PCL remaining following the cut was categorized into five different groups: 0% (no PCL undermined), 1-49%, 50-74%, 75-99% and 100% (PCL undermined entirely). Overall only 9.0% (n=11) would have not endured any damage to the PCL with a transverse tibial saw cut, while 79.6% (n=98) would have had 50% or more of the PCL undermined. Of the 98 patients with more than 50% resected, 52.1% (n=51 patients) presented complete destabilization of the PCL. The percentage of PCL destabilized was not significant across age groups (p=0.280), gender (p=0.586), or operative side (p=0.460). Independent of age, gender, and operative side, a majority of PCLs are more than 50% destabilized following the standard transverse tibial cut. II. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. The comparison of clinical features and quality of life after total knee replacement.

    Science.gov (United States)

    Lee, Jiyeon; Kim, Jung-Hee; Jung, Eun-Jung; Lee, Byoung-Hee

    2017-06-01

    [Purpose] The purpose of this study is to provide fundamental information for efficient management of patients after a total knee replacement (TKR) through the evaluation of changes of range of motion, pain, functional level, and quality of life. [Subjects and Methods] For a total of 63 knee osteoarthritis patients, VAS, KSKS, KSFS, HSS, WOMAC scores and quality of life were evaluated for functional levels at pre-operation, post-operation, six months after operation, and 12 months after operation. [Results] After the TKR operations, participants showed significant improvement in KSKS, KSFS, WOMAC, and SF-36 scores when compared to pre-operation. [Conclusion] After a TKR operation, ROM, and pain management, along with a therapeutic program for improvement of function, should be conducted 6 months after the operation.

  9. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    Science.gov (United States)

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  10. Patellar denervation with electrocautery in total knee arthroplasty without patellar resurfacing: a meta-analysis.

    Science.gov (United States)

    Cheng, Tao; Zhu, Chen; Guo, Yongyuan; Shi, Sifeng; Chen, Desheng; Zhang, Xianlong

    2014-11-01

    The impact of patellar denervation with electrocautery in total knee arthroplasty (TKA) on post-operative outcomes has been under debate. This study aims to conduct a meta-analysis and systematic review to compare the benefits and risks of circumpatellar electrocautery with those of non-electrocautery in primary TKAs. Comparative and randomized clinical studies were identified by conducting an electronic search of articles dated up to September 2012 in PubMed, EMBASE, Scopus, and the Cochrane databases. Six studies that focus on a total of 849 knees were analysed. A random-effects model was conducted using the inverse-variance method for continuous variables and the Mantel-Haenszel method for dichotomous variables. There was no significant difference in the incidence of anterior knee pain between the electrocautery and non-electrocautery groups. In term of patellar score and Knee Society Score, circumpatellar electrocautery improved clinical outcomes compared with non-electrocautery in TKAs. The statistical differences were in favour of the electrocautery group but have minimal clinical significance. In addition, the overall complications indicate no statistical significance between the two groups. This study shows no strong evidence either for or against electrocautery compared with non-electrocautery in TKAs. Therapeutic study (systematic review and meta-analysis), Level III.

  11. Resource use and costs associated with opioid-induced constipation following total hip or total knee replacement surgery

    Directory of Open Access Journals (Sweden)

    Wittbrodt ET

    2018-05-01

    Full Text Available Eric T Wittbrodt,1 Tong J Gan,2 Catherine Datto,1 Charles McLeskey,1 Meenal Sinha3 1US Medical Affairs, AstraZeneca, Wilmington, DE, USA; 2Department of Anesthesiology, Stony Brook Medicine, Stony Brook, NY, USA; 3Premier Applied Sciences, Premier, Inc., Charlotte, NC, USA Purpose: Constipation is a well-known complication of surgery that can be exacerbated by opioid analgesics. This study evaluated resource utilization and costs associated with opioid-induced constipation (OIC. Patients and methods: This retrospective, observational, and propensity-matched cohort study utilized the Premier Healthcare Database. The study included adults ≥18 years of age undergoing total hip or total knee replacement as inpatients who received an opioid analgesic and were discharged between January 1, 2012, and June 30, 2015. Diagnosis codes identified patients with OIC who were then matched 1:1 to patients without OIC. Generalized linear and logistic regression models were used to compare inpatient resource utilization, total hospital costs, inpatient mortality, and 30-day all-cause readmissions and emergency department visits. Results: Of 788,448 eligible patients, 40,891 (5.2% had OIC. Covariates were well balanced between matched patients with and without OIC (n=40,890 each. In adjusted analyses, patients with OIC had longer hospital lengths of stay (3.6 versus 3.3 days; p<0.001, higher total hospital costs (US$17,479 versus US$16,265; p<0.001, greater risk of intensive care unit admission (odds ratio [OR]=1.12, 95% CI: 1.01–1.24, and increased likelihood of 30-day hospital readmissions (OR=1.16, 95% CI: 1.11–1.22 and emergency department visits (OR=1.38, 95% CI: 1.07–1.79 than patients without OIC. No statistically significant difference was found with inpatient mortality (OR=0.89, 95% CI: 0.59–1.35. Conclusion: OIC was associated with greater resource utilization and hospital costs for patients undergoing primarily elective total hip or total knee

  12. OPTIMAL IMPROVEMENT IN FUNCTION AFTER TOTAL HIP AND KNEE REPLACEMENT: HOW DEEP DO YOU KNOW YOUR PATIENT’S MIND?

    Science.gov (United States)

    De Caro, M F; Vicenti, G; Abate, A; Picca, G; Leoncini, V; Lomuscio, M; Casalino, A; Solarino, G; Moretti, B

    2015-01-01

    Osteoarthritis (OA) of the hip and knee causes pain and loss of joint mobility, leading to limitations in physical function. When conservative treatment fails total hip and knee replacement is a cost-effective surgical option. Patients have high expectations regarding functional outcome after these procedures. If such expectations are not met, they may still be dissatisfied with the outcome of a technically successful procedure. Recently, numerous studies reported that psychological factors can influence the outcome of total knee replacement (tkr) and total hip artrhoplasty with total hip replacement (thr). We conducted a prospective study on a consecutive sample of 280 patients affected by hip or knee OA who underwent total joint replacement. At patients’ admission, Harris Hip Score (HHS) and Knee Society Score (KSS) were used to assess pain and function. Furthermore, SF-36, Mini-Mental Status Examination (MMSE), Symptom Checklist-90-R (SCL-90-R), Coping Orientation to Problems Experienced (BRIEF-COPE) and the Amsterdam Preoperative Anxiety and Information Scale (APAIS) were administered. Patients had clinical and radio graphical follow up at 1, 3 and 6 months post-operatively. The HHS and KSS values before surgery showed a linear correlation with both SCL-90-R and MMSE. None of the investigated variables influenced post-operative HHS and KSS scores; however, the improvement of functional scores resulted conditioned by SCL-90-R values, VAS score, schooling and MMSE. Psychological factors and mental status in primary total hip and knee replacement can affect outcome and patient satisfaction. Strategies focused on identification and facing of these conditions must be considered to improve outcome of total replacement.

  13. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    Science.gov (United States)

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  14. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    Science.gov (United States)

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  15. Management of knee rheumatoid arthritis and tibia nonunion with one-stage total knee arthroplasty and intramedullary nailing: A report of two cases

    Directory of Open Access Journals (Sweden)

    Fahri Erdogan

    2018-01-01

    Full Text Available Total knee arthroplasty (TKA is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA. The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture.

  16. C-reactive protein, erythrocyte sedimentation rate and orthopedic implant infection.

    Directory of Open Access Journals (Sweden)

    Kerryl E Piper

    Full Text Available BACKGROUND: C-reactive protein (CRP and erythrocyte sedimentation rate (ESR have been shown to be useful for diagnosis of prosthetic hip and knee infection. Little information is available on CRP and ESR in patients undergoing revision or resection of shoulder arthroplasties or spine implants. METHODS/RESULTS: We analyzed preoperative CRP and ESR in 636 subjects who underwent knee (n=297, hip (n=221 or shoulder (n=64 arthroplasty, or spine implant (n=54 removal. A standardized definition of orthopedic implant-associated infection was applied. Receiver operating curve analysis was used to determine ideal cutoff values for differentiating infected from non-infected cases. ESR was significantly different in subjects with aseptic failure infection of knee (median 11 and 53.5 mm/h, respectively, p=<0.0001 and hip (median 11 and 30 mm/h, respectively, p=<0.0001 arthroplasties and spine implants (median 10 and 48.5 mm/h, respectively, p=0.0033, but not shoulder arthroplasties (median 10 and 9 mm/h, respectively, p=0.9883. Optimized ESR cutoffs for knee, hip and shoulder arthroplasties and spine implants were 19, 13, 26, and 45 mm/h, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 89 and 74% for knee, 82 and 60% for hip, and 32 and 93% for shoulder arthroplasties, and 57 and 90% for spine implants. CRP was significantly different in subjects with aseptic failure and infection of knee (median 4 and 51 mg/l, respectively, p<0.0001, hip (median 3 and 18 mg/l, respectively, p<0.0001, and shoulder (median 3 and 10 mg/l, respectively, p=0.01 arthroplasties, and spine implants (median 3 and 20 mg/l, respectively, p=0.0011. Optimized CRP cutoffs for knee, hip, and shoulder arthroplasties, and spine implants were 14.5, 10.3, 7, and 4.6 mg/l, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 79 and 88% for knee, 74 and 79% for hip, and 63 and 73% for shoulder arthroplasties, and 79 and

  17. Oxford Partial Knee Replacement as a Gateway to Outpatient Arthroplasty “Lessons Learned along the Journey”

    Directory of Open Access Journals (Sweden)

    Michael E Berend

    2016-09-01

    Full Text Available The Oxford Partial Knee Replacement was approved for implantation in the US in 2004 after the surgeon completed an educational training requirement.  Since then my knee practiced has expanded to over 50% partial knee.  This experience coupled with refinement of surgical techniques, anesthesia protocols, and patient selection has facilitated the transformation to same day discharge for partial knee cases and has quickly transitioned to total hip, total knee, and selected revision surgeries.  Patient selection has also expanded for outpatient joints and is now based on medical screening criteria and insurance access.  Over a two-year period we have performed over 1,000 outpatient arthroplasty procedures with no readmissions for pain control.   Overall readmission rate for all reasons was 2%.  Patient satisfaction scores were 98% Great-Good for 2014-15.  The combination of a partial knee replacement practice and an outpatient joint program brings the best VALUE to the patients, surgeons, and the arthroplasty system and represents the future of arthroplasty care.

  18. Ochronosis of the knee with secondary osteoarthritis requiring total knee replacement in a patient with cryptogenic organising pneumonia.

    Science.gov (United States)

    Jasper, Jorrit; Metsaars, Wieneke; Jansen, Joris

    2016-05-20

    Ochronosis is a rare autosomal recessive metabolic disease caused by homogentisic acid oxidase enzyme deficiency. High homogentisic acid levels will eventually result in black deposits in skin, sclerae, connective tissues and urine (alkaptonuria). It can lead to early degeneration of connective tissues and cartilage. Ochronosis can damage normal cartilage, leading to secondary osteoarthritis. The diagnosis is often delayed because of its low prevalence and non-specific early symptoms. In our patient, the secondary osteoarthritis due to ochronosis deposits in the cartilage was treated by total knee arthroplasty, with good clinical outcome. This article reports the first case of ochronosis with secondary osteoarthritis of the knee in a patient previously diagnosed with cryptogenic organising pneumonia (COP). 2016 BMJ Publishing Group Ltd.

  19. Use of antibiotic-loaded cement in total knee arthroplasty.

    OpenAIRE

    Hinarejos Gómez, Pedro Angel; Guirro Castellnou, Pau; Puig Verdié, Luís; Torres Claramunt, Raúl; Leal Blanquet, Joan; Sánchez Soler, JF.; Monllau García, Juan Carlos

    2015-01-01

    Bone cement has the capacity to release antibiotic molecules if any antibiotic is included in it, and these elution properties are improved as cement porosity is increased. In vitro studies have shown high local antibiotic concentration for many hours or few days after its use. Antibiotic loaded bone cement (ALBC) is helpful when treating an infection in total knee arthroplasty (TKA) revision surgery. The purpose of this paper was to review the evidence for the routine use of ALBC in TKA in t...

  20. Variation in age and physical status prior to total knee and hip replacement surgery

    DEFF Research Database (Denmark)

    Ackerman, Ilana N; Dieppe, Paul A; March, Lyn M

    2009-01-01

    OBJECTIVE: To investigate whether variation exists in the preoperative age, pain, stiffness, and physical function of people undergoing total knee replacement (TKR) and total hip replacement (THR) at several centers in Australia and Europe. METHODS: Individual Western Ontario and McMaster Univers...

  1. Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants.

    Science.gov (United States)

    Nuño, N; Groppetti, R; Senin, N

    2006-11-01

    Design of cemented hip and knee implants, oriented to improve the longevity of artificial joints, is largely based on numerical models. The static coefficient of friction between the implant and the bone cement is necessary to characterize the interface conditions in these models and must be accurately provided. The measurement of this coefficient using a repeatable and reproducible methodology for materials used in total hip arthroplasty is missing from the literature. A micro-topographic surface analysis characterized the surfaces of the specimens used in the experiments. The coefficient of friction between stainless steel and bone cement in dry and wet conditions using bovine serum was determined using a prototype computerized sliding friction tester. The effects of surface roughness (polished versus matt) and of contact pressure on the coefficient of friction have also been investigated. The serum influences little the coefficient of friction for the matt steel surface, where the mechanical interactions due to higher roughness are still the most relevant factor. However, for polished steel surfaces, the restraining effect of proteins plays a very relevant role in increasing the coefficient of friction. When the coefficient of friction is used in finite element analysis, it is used for the debonded stem-cement situation. It can thus be assumed that serum will propagate between the stem and the cement mantle. The authors believe that the use of a static coefficient of friction of 0.3-0.4, measured in the present study, is appropriate in finite element models.

  2. Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    James M. Economides

    2017-03-01

    Full Text Available BackgroundIn cases of total knee arthroplasty (TKA threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA.MethodsA systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis.ResultsA total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05 and limb salvage (89.8% vs. 100%, P=0.14 were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78, the rates of persistent infection (16.4% vs. 0%, P=0.14 and recurrent infection (9.1% vs. 4%, P=0.94 tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported.ConclusionsRates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

  3. Custom rotating hinge total knee arthroplasty in patients with poliomyelitis affected limbs.

    Science.gov (United States)

    Rahman, Jeeshan; Hanna, Sammy A; Kayani, Babar; Miles, Jonathan; Pollock, Robin C; Skinner, John A; Briggs, Timothy W; Carrington, Richard W

    2015-05-01

    Total knee arthroplasty (TKA) in limbs affected by poliomyelitis is a technically challenging procedure. These patients often demonstrate acquired articular and metaphyseal angular deformities, bone loss, narrowness of the intramedullary canals, impaired quadriceps strength, flexion contractures and ligamentous laxity producing painful hyperextension. Thus, using condylar knee designs in these patients will likely result in early failure because of instability and abnormal load distribution. The aim of this study was to assess the outcomes associated with use of the customised (SMILES) rotating-hinge knee system at our institution for TKA in poliomyelitis-affected limbs. We retrospectively reviewed the outcome of 14 TKAs using the (SMILES) prosthesis in 13 patients with limbs affected by poliomyelitis. All patients had painful unstable knees with hyperextension. There were ten females and three males with a mean age of 66 years (range 51-84) at time of surgery. Patients were followed up clinically, radiologically and functionally with the Oxford knee score (OKS). Mean follow-up was 72 months (16-156). There were no immediate or early complications. One patient fell and sustained a peri-prosthetic fracture at seven months requiring revision to a longer stem. Radiological evaluation showed satisfactory alignment with no signs of loosening in all cases. Mean OKS improved from 11.6 (4-18) to 31.5 (18-40) postoperatively (p poliomyelitis. The device compensates well for ligamentous insufficiency as well as for any associated bony deformity.

  4. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experiences with quality of care after a total hip or knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Delnoij Diana MJ

    2007-04-01

    Full Text Available Abstract Background The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA or total knee arthroplasty (TKA. The aim of this study is to evaluate the construct validity and internal consistency reliability of this new instrument and to assess its ability to measure differences in quality of care between hospitals. Methods Survey data of 1,675 subjects who underwent a THA or TKA were used to evaluate the psychometric properties. Exploratory factor analyses were performed and item-total correlations and inter-factor correlations were calculated to assess the construct validity of the instrument. Reliability analyses included tests of internal consistency (Cronbach's alpha coefficients. Finally, multilevel analyses were performed to assess the ability of the instrument to discriminate between hospitals in quality of care. Results Exploratory factor analyses indicated that the survey consisted of 21 items measuring five aspects of care (i.e. communication with nurses, communication with doctors, communication with general practitioner, communication about new medication, and pain control. Cronbach's alpha coefficients ranged from 0.76 to 0.90 indicating good internal consistency. The survey's ability to discriminate between hospitals was partly supported by multilevel analysis. Two scales (i.e. communication with nurses and communication with doctors were able to measure differences between hospitals with respect to patients' experiences with quality of care. Logistic multilevel analyses indicated that hospitals explained part of the variation between patients in receiving information. Conclusion These findings suggest that the CQI Hip Knee is reliable and valid for use in Dutch health care. Health care providers or health plans can use this survey to measure patients' experiences with hospital care and to identify variations in care

  5. Trichosporon Asahii Infection after Total Knee Arthroplasty: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Qiang Zuo

    2015-01-01

    Full Text Available Reports of fungal infection after total knee arthroplasty are extremely rare. In most reports, the infecting organism is a Candida species. The present report describes a case involving a 73-year-old immunocompetent woman who underwent total knee arthroplasty and presented one month later with signs of prosthetic infection. She underwent joint debridement and the fluid was sent for culture and sensitivity testing. The culture showed growth of Trichosporon asahii. The patient was administered intravenous and intra-articular injections of amphotericin B, followed by antifungal treatment with voriconazole for one year. At 26 months of follow-up, there was no evidence of infection and the patient was ambulating with a walker. To the authors’ knowledge, the present case is the first report of T asahii infection following knee replacement. Early detection, prompt institution of the appropriate antibiotics and regular follow-up are recommended.

  6. Patient-Controlled Oral Analgesia for Postoperative Pain Management Following Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Patti Kastanias

    2010-01-01

    Full Text Available PURPOSE: To investigate whether patient-controlled oral analgesia (PCOA used by individuals receiving a total knee replacement could reduce pain, increase patient satisfaction, reduce opioid use and/or reduce opioid side effects when compared with traditional nurse (RN-administered oral analgesia.

  7. Racial and Ethnic Differences in Total Knee Arthroplasty in the Veterans Affairs Health Care System, 2001-2013.

    Science.gov (United States)

    Hausmann, Leslie R M; Brandt, Cynthia A; Carroll, Constance M; Fenton, Brenda T; Ibrahim, Said A; Becker, William C; Burgess, Diana J; Wandner, Laura D; Bair, Matthew J; Goulet, Joseph L

    2017-08-01

    To examine black-white and Hispanic-white differences in total knee arthroplasty from 2001 to 2013 in a large cohort of patients diagnosed with osteoarthritis (OA) in the Veterans Affairs (VA) health care system. Data were from the VA Musculoskeletal Disorders cohort, which includes data from electronic health records of more than 5.4 million veterans with musculoskeletal disorders diagnoses. We included white (non-Hispanic), black (non-Hispanic), and Hispanic (any race) veterans, age ≥50 years, with an OA diagnosis from 2001-2011 (n = 539,841). Veterans were followed from their first OA diagnosis until September 30, 2013. As a proxy for increased clinical severity, analyses were also conducted for a subsample restricted to those who saw an orthopedic or rheumatology specialist (n = 148,844). We used Cox proportional hazards regression to examine racial and ethnic differences in total knee arthroplasty by year of OA diagnosis, adjusting for age, sex, body mass index, physical and mental diagnoses, and pain intensity scores. We identified 12,087 total knee arthroplasty procedures in a sample of 473,170 white, 50,172 black, and 16,499 Hispanic veterans. In adjusted models examining black-white and Hispanic-white differences by year of OA diagnosis, total knee arthroplasty rates were lower for black than for white veterans diagnosed in all but 2 years. There were no Hispanic-white differences regardless of when diagnosis occurred. These patterns held in the specialty clinic subsample. Black-white differences in total knee arthroplasty appear to be persistent in the VA, even after controlling for potential clinical confounders. © 2016, American College of Rheumatology.

  8. Ica-expression and gentamicin susceptibility of Staphylococcus epidermidis biofilm on orthopedic implant biomaterials

    NARCIS (Netherlands)

    Nuryastuti, Titik; Krom, Bastiaan P.; Aman, Abu T.; Busscher, Henk J.; van der Mei, Henny C.

    Ica-expression by Staphylococcus epidermidis and slime production depends on environmental conditions such as implant material and presence of antibiotics. Here, we evaluate biofilm formation and ica-expression of S. epidermidis strains on biomaterials involved in total hip-and knee arthroplasty

  9. Total Artificial Heart Implantation After Undifferentiated High-Grade Sarcoma Excision.

    Science.gov (United States)

    Kremer, Jamila; Farag, Mina; Arif, Rawa; Brcic, Andreas; Sabashnikov, Anton; Schmack, Bastian; Popov, Aron-Frederik; Karck, Matthias; Dohmen, Pascal M; Ruhparwar, Arjang; Weymann, Alexander

    2016-11-02

    BACKGROUND Total artificial heart (TAH) implantation in patients with aggressive tumor infiltration of the heart can be challenging. CASE REPORT We report on a patient with a rare primary undifferentiated high-grade spindle cell sarcoma of the mitral valve and in the left atrium, first diagnosed in 2014. The referring center did a first resection in 2014. In the course of 17 months, computer tomography (CT) scan again showed massive invasion of the mitral valve and left atrium. Partial resection and mitral valve replacement was not an option. We did a subtotal heart excision with total artificial heart implantation. In this report we discuss complications, risk factors, and perioperative management of this patient. CONCLUSIONS Patients with aggressive tumors of the heart can be considered for TAH implantation.

  10. Perioperative plasmatic presepsin levels in patients undergoing total hip or knee replacement: a preliminary study.

    Science.gov (United States)

    Vicenti, G; Pesce, V; Bizzoca, D; Nappi, V; Palmiotto, F; Carrozzo, M; Moretti, B

    2017-01-01

    Presepsin (sCD14-ST) is an emerging biomarker in the diagnosis of sepsis. In the field of orthopaedics, it could be useful in the diagnosis and management of periprosthetic joint infections (PJI). The aim of this study is to define the normal perioperative plasmatic levels of presepsin in patients undergoing primary cementless total hip replacement (THR) or primary cemented total knee replacement (TKR). For this purpose, 50 patients (19 male, 31 female, mean age= 64.04±8.88) were recruited. The patients were divided into two groups: Group A patients underwent cementless THR, whereas Group B patients underwent cemented TKR. On recruitment, anthropometric data, smocking status, osteoarthritis stage according to Kellgren and Lawrence, Harris Hip Score (HHS) for Group A patients and Knee Society Score (KSS) for Group B patients, drugs assumption and comorbidities were recorded. All the patients underwent serial blood tests, including complete blood count, presepsin (PS), C-reactive protein (CRP) and procalcitonin (PCT) 24 hours before arthroplasty (T0) and at 24 (T1), 48 (T2), 72 (T3) and 96 (T4) hours postoperatively. Body temperature (θ) was recorded every six hours in the time lapse T0-T4. Presepsin plasmatic concentration was comparable at baseline in both groups. After surgery, however, a significant increase of presepsin was observed in Group A, whereas in Group B no significant changes of presepsin were recorded. A comparable trend of this biomarker was found in the two groups, i.e. presepsin increased from T0 to T3, when it reached its maximum value, and its decrease started at T4. Finally, presepsin resulted more accurate than CRP in the evaluation of perioperative inflammatory response in patients undergoing THR or TKR. These data will be helpful in defining a reference interval for presepsin in patients with prosthetic joint implants, and a cut-off of this biomarker for the diagnosis of PJI.

  11. Multifaceted Comparison of Two Cryotherapy Devices Used After Total Knee Arthroplasty: Cryotherapy Device Comparison.

    Science.gov (United States)

    Schinsky, Mark F; McCune, Christine; Bonomi, Judith

    2016-01-01

    Some form of cryotherapy used after total knee arthroplasty is commonplace. However, various factors determine the specific device deployed. This study aimed to answer the following questions: : A group of 100 patients undergoing primary total knee arthroplasty by a single surgeon were enrolled in an institutional review board-approved, prospective study and randomized to receive either a circulating cold water or ice/gel pack cryotherapy device postoperatively. Demographic, pain, swelling, blood loss, range of motion, compliance, satisfaction, and adverse event outcomes were recorded until 6 weeks after surgery. Hospital staff satisfaction and economic variables were examined. The ice/gel pack cryotherapy wrap was noninferior to the cold water cryotherapy device for any patient outcome measured. Average pain level at 6 weeks postoperative was significantly less in the ice/gel pack cryotherapy wrap group. Hospital staff satisfaction was higher with the ice/gel pack cryotherapy wrap.Substantial economic savings can be realized at our institution by switching to the lower cost cryotherapy device. In this study, the lower cost ice/gel pack cryotherapy wrap was noninferior to the circulating ice water cryotherapy device with respect to objective patient outcomes and subjective patient satisfaction after total knee arthroplasty. Hospital staff satisfaction and economic considerations also favor the ice/gel pack compression cryotherapy wraps.

  12. The efficacy of 12 weeks non-surgical treatment for patients not eligible for total knee replacement

    DEFF Research Database (Denmark)

    Skou, Søren Thorgaard; Rasmussen, Sten; Laursen, Mogens Berg

    2015-01-01

    OBJECTIVE: To compare the efficacy of a 12-week non-surgical treatment program with usual care in patients with knee osteoarthritis (OA) not eligible for total knee replacement (TKR). METHOD: This two-arm parallel group assessor-blinded randomized controlled trial (RCT) included 100 adults from...... secondary care with knee OA, confirmed by radiography (Kellgren-Lawrence grade ≥1), but not eligible for a TKR. The 12-week non-surgical treatment program consisted of individualized progressed neuromuscular exercise, patient education, insoles, dietary advice and prescription of pain medication...... if indicated, while usual care comprised two leaflets with information and advice on knee OA and recommended treatments. The primary outcome was the change from baseline to 12 months in the Knee injury and Osteoarthritis Outcome Score (KOOS)4 defined as the average score for the KOOS subscales of pain...

  13. Safety of blood reinfusion after local infiltration analgesia with ropivacaine in total knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, Bregje J.W.; Touw, Daan; Van Der Woude, Pieter; Van Der Flier, Rudolf E.; Veld, Bastiaan A.

    2014-01-01

    Objective: The authors hypothesized that it is safe to combine local infiltration analgesia (LIA) in total knee arthroplasty (TKA) with a retransfusion drain since ropivacaine concentrations would not exceed the arterial toxicity threshold concentrations of 4.3 mg/L for total and 0.56 mg/L for

  14. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the tra...

  15. Effect of early release of tourniquet in total knee arthroplasty

    International Nuclear Information System (INIS)

    Abbas, K.; Raza, H.; Umer, M.; Hafiz, K.

    2013-01-01

    To evaluate whether tourniquet release intraoperatively is better than postoperative release in reducing overall blood loss, duration of surgery, duration of tourniquet, length of hospital stay, wound related complications and transfusion requirement. Study Design: Comparative study. Place and Duration of Study: Department of Surgery, The Aga Khan University Hospital, Karachi, from January 2004 to June 2007. Methodology: One hundred and thirty patient files were reviewed retrospectively. Patients were divided into two groups. Group-A consisted of 65 patients with early deflation of tourniquet and group-B comprised of 65 patients with the release of tourniquet after applying compressive dressing. Total blood loss (determined by Gross method) and other study variables were noted as per objective and computed. Results: There were 22 males and 108 females with comparable BMI. All had undergone posterior stabilized cemented total knee replacement. Calculated blood loss was 1.208 L and 1.108 L in group-A and B respectively (p = 0.27). Significant increase in duration of surgery was noted in group-A patients. Four patients in group-B showed complication related to wound with 3 being minor and 1 requiring additional operation room visit. Mean length of hospital stay was 9 days. Transfusion frequency was higher in group-B despite comparable postoperative haemoglobin values. Conclusion: Intraoperative tourniquet release does not reduce overall blood loss with no effect in conserving blood after total knee replacement, however, this group had relatively shorter hospital stay. (author)

  16. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.

    Science.gov (United States)

    Watanabe, Toshifumi; Koga, Hideyuki; Horie, Masafumi; Katagiri, Hiroki; Sekiya, Ichiro; Muneta, Takeshi

    2017-12-01

    The post-cam mechanism in posterior stabilized (PS) prostheses plays an important role in total knee arthroplasty (TKA). The purpose of this study is to clarify the difference of the contact stress on the tibial post between a rounded post-cam design and a squared design during deep knee flexion and at hyperextension using the three-dimensional (3D) finite element models. We created 2 types of 3D, finite element models of PS prostheses (types A and B), whose surfaces were identical except for the post-cam geometries: type A has a rounded post-cam design, while type B has a squared design. Both types have a similar curved-shape intercondylar notch of the femoral component. Stress distributions, peak contact stresses, and contact areas on the tibial posts at 90°, 120°, and 150° flexion with/without 10° tibial internal rotation and at 10° hyperextension were compared between the 2 models. Type B demonstrated more concentrated stress distribution compared to type A. The peak contact stresses were similar in both groups during neutral flexion; however, the stresses were much higher in type B during flexion with 10° rotation and at hyperextension. The higher peak contact stresses corresponded to the smaller contact areas in the tibial post. A rounded post-cam design demonstrated less stress concentration during flexion with rotation and at hyperextension compared with a squared design. The results would be useful for development of implant designs and prediction of the contact stress on the tibial post in PS total knee arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Home-Based versus Hospital-Based Rehabilitation Program after Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Remedios López-Liria

    2015-01-01

    Full Text Available Objectives. To compare home-based rehabilitation with the standard hospital rehabilitation in terms of improving knee joint mobility and recovery of muscle strength and function in patients after a total knee replacement. Materials and Methods. A non-randomised controlled trial was conducted. Seventy-eight patients with a prosthetic knee were included in the study and allocated to either a home-based or hospital-based rehabilitation programme. Treatment included various exercises to restore strength and joint mobility and to improve patients’ functional capacity. The primary outcome of the trial was the treatment effectiveness measured by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC. Results. The groups did not significantly differ in the leg side (right/left or clinical characteristics (P>0.05. After the intervention, both groups showed significant improvements (P<0.001 from the baseline values in the level of pain (visual analogue scale, the range of flexion-extension motion and muscle strength, disability (Barthel and WOMAC indices, balance, and walking. Conclusions. This study reveals that the rehabilitation treatments offered either at home or in hospital settings are equally effective.

  18. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics.

    Science.gov (United States)

    Leichtle, Ulf G; Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I; Wülker, Nikolaus; Lorenz, Andrea

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt ( p patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA.

  19. Hybrid micro/nano-topography of a TiO2 nanotube-coated commercial zirconia femoral knee implant promotes bone cell adhesion in vitro.

    Science.gov (United States)

    Frandsen, Christine J; Noh, Kunbae; Brammer, Karla S; Johnston, Gary; Jin, Sungho

    2013-07-01

    Various approaches have been studied to engineer the implant surface to enhance bone in-growth properties, particularly using micro- and nano-topography. In this study, the behavior of osteoblast (bone) cells was analyzed in response to a titanium oxide (TiO2) nanotube-coated commercial zirconia femoral knee implant consisting of a combined surface structure of a micro-roughened surface with the nanotube coating. The osteoblast cells demonstrated high degrees of adhesion and integration into the surface of the nanotube-coated implant material, indicating preferential cell behavior on this surface when compared to the bare implant. The results of this brief study provide sufficient evidence to encourage future studies. The development of such hierarchical micro- and nano-topographical features, as demonstrated in this work, can provide insightful designs for advanced bone-inducing material coatings on ceramic orthopedic implant surfaces. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Interventions for the prediction and management of chronic postsurgical pain after total knee replacement: systematic review of randomised controlled trials.

    Science.gov (United States)

    Beswick, Andrew D; Wylde, Vikki; Gooberman-Hill, Rachael

    2015-05-12

    Total knee replacement can be a successful operation for pain relief. However, 10-34% of patients experience chronic postsurgical pain. Our aim was to synthesise evidence on the effectiveness of applying predictive models to guide preventive treatment, and for interventions in the management of chronic pain after total knee replacement. We conducted a systematic review of randomised controlled trials using appropriate search strategies in the Cochrane Library, MEDLINE and EMBASE from inception to October 2014. No language restrictions were applied. Adult patients receiving total knee replacement. Predictive models to guide treatment for prevention of chronic pain. Interventions for management of chronic pain. Reporting of specific outcomes was not an eligibility criterion but we sought outcomes relating to pain severity. No studies evaluated the effectiveness of predictive models in guiding treatment and improving outcomes after total knee replacement. One study evaluated an intervention for the management of chronic pain. The trial evaluated the use of a botulinum toxin A injection with antinociceptive and anticholinergic activity in 49 patients with chronic postsurgical pain after knee replacement. A single injection provided meaningful pain relief for about 40 days and the authors acknowledged the need for a large trial with repeated injections. No trials of multidisciplinary interventions or individualised treatments were identified. Our systematic review highlights a lack of evidence about the effectiveness of prediction and management strategies for chronic postsurgical pain after total knee replacement. As a large number of people are affected by chronic pain after total knee replacement, development of an evidence base about care for these patients should be a research priority. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Total knee replacement plus physical and medical therapy or treatment with physical and medical therapy alone

    DEFF Research Database (Denmark)

    Skou, Søren Thorgaard; Roos, Ewa M.; Laursen, Mogens Berg

    2012-01-01

    ABSTRACT: BACKGROUND: There is a lack of high quality evidence concerning the efficacy of total knee arthroplasty (TKA). According to international evidence-based guidelines, treatment of knee osteoarthritis (KOA) should include patient education, exercise and weight loss. Insoles....../or NSAIDs. Patients will be randomised to either receiving or not receiving a TKA in addition to the optimised non-surgical treatment. The primary outcome will be the change from baseline to 12 months on the Knee Injury and Osteoarthritis Outcome Score (KOOS)4 defined as the average score for the subscale...

  2. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-11-01

    PEEK-OPTIMA ™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA ™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA ™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm 3 /million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm 3 /million cycles and 2.44 ± 0.78 mm 3 /million cycle against cobalt chrome and PEEK-OPTIMA ™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm 3 /million cycles and 4.44 ± 2.35 mm 3 /million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA ™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA ™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of

  3. PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study

    Science.gov (United States)

    Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M

    2016-01-01

    PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These

  4. The influence of tourniquet use and operative time on the incidence of deep vein thrombosis in total knee arthroplasty.

    Science.gov (United States)

    Hernandez, Arnaldo José; Almeida, Adriano Marques de; Fávaro, Edmar; Sguizzato, Guilherme Turola

    2012-09-01

    To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: 120 minutes. Three categories were defined for operative time: 150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.

  5. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    Science.gov (United States)

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  6. Numerical analysis of variations in posterior cruciate ligament properties and balancing techniques on total knee arthroplasty loading.

    NARCIS (Netherlands)

    Zelle, J.; Heesterbeek, P.J.; De Waal Malefijt, M.; Verdonschot, Nicolaas Jacobus Joseph

    2010-01-01

    Total knee arthroplasty (TKA) is a widely used and successful orthopaedic procedure. During TKA, the posterior cruciate ligament (PCL) can either be retained or substituted by a post-cam mechanism. One of the main functions of the PCL is to facilitate femoral rollback during knee flexion. For

  7. Patient satisfaction after total knee arthroplasty: an Asian perspective.

    Science.gov (United States)

    Thambiah, Matthew Dhanaraj; Nathan, Sahaya; Seow, Branden Z X; Liang, Shen; Lingaraj, Krishna

    2015-05-01

    Total knee arthroplasty (TKA) is an effective method for alleviating pain and restoring knee function in patients with severe osteoarthritis. However, despite the improvements in surgical technique and postoperative care, it has been reported that up to 19% of patients are dissatisfied after their operations. The aim of this study was to evaluate patient satisfaction levels after TKA in an Asian cohort, as well as assess the correlation between patient satisfaction levels and the results of traditional physician-based scoring systems. The medical data of 103 Asian patients who underwent 110 TKAs between December 2008 and June 2009 were obtained from our hospital's Joint Replacement Registry. The minimum follow-up period was one year and patient expectations were assessed before TKA. Patient satisfaction was assessed postoperatively using a 5-point Likert scale. Reasons for patient dissatisfaction were recorded. Standardised instruments (e.g. the Knee Society Score, the Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC] and the generic Short Form-36 health survey) were used to assess the patient's functional status and the severity of symptoms pre- and postoperatively. Among the 110 TKAs performed, 92.8% resulted in patient satisfaction. Patient satisfaction correlated with postoperative WOMAC function scores (p = 0.028), postoperative WOMAC final scores (p = 0.040) and expectations being met (p = 0.033). Although there was a high level of patient satisfaction following TKA in our cohort of Asian patients, a significant minority was dissatisfied. Patient satisfaction is an important outcome measure and should be assessed in addition to traditional outcome scores.

  8. Effect of adductor-canal-blockade on established, severe post-operative pain after total knee arthroplasty

    DEFF Research Database (Denmark)

    Jaeger, P; Grevstad, Ulrik; Henningsen, Maja

    2012-01-01

    In this proof-of-concept study, we investigated the effect of the predominantly sensory adductor-canal-blockade on established pain in the early post-operative period after total knee arthroplasty (TKA). We hypothesised that the adductor-canal-blockade would reduce pain during flexion of the knee...... (primary end point) and at rest, as well as reducing morphine consumption and morphine-related side effects (secondary outcomes) compared with placebo....

  9. The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic.

    Science.gov (United States)

    Losina, Elena; Thornhill, Thomas S; Rome, Benjamin N; Wright, John; Katz, Jeffrey N

    2012-02-01

    Total knee replacement utilization in the United States more than doubled from 1999 to 2008. Although the reasons for this increase have not been examined rigorously, some have attributed the increase to population growth and the obesity epidemic. Our goal was to investigate whether the rapid increase in total knee replacement use over the past decade can be sufficiently attributed to changes in these two factors. We used data from the Nationwide Inpatient Sample to estimate changes in total knee replacement utilization rates from 1999 to 2008, stratified by age (eighteen to forty-four years, forty-five to sixty-four years, and sixty-five years or older). We obtained data on obesity prevalence and U.S. population growth from federal sources. We compared the rate of change in total knee replacement utilization with the rates of population growth and change in obesity prevalence from 1999 to 2008. In 2008, 615,050 total knee replacements were performed in the United States adult population, 134% more than in 1999. During the same time period, the overall population size increased by 11%. While the population of forty-five to sixty-four-year-olds grew by 29%, the number of total knee replacements in this age group more than tripled. The number of obese and non-obese individuals in the United States increased by 23% and 4%, respectively. Assuming unchanged indications for total knee replacement among obese and non-obese individuals with knee osteoarthritis over the last decade, these changes fail to account for the 134% growth in total knee replacement use. Population growth and obesity cannot fully explain the rapid expansion of total knee replacements in the last decade, suggesting that other factors must also be involved. The disproportionate increase in total knee replacements among younger patients may be a result of a growing number of knee injuries and expanding indications for the procedure.

  10. Knee Joint Distraction Compared to Total Knee Arthroplasty for Treatment of End Stage Osteoarthritis: Simulating Long-Term Outcomes and Cost-Effectiveness.

    Science.gov (United States)

    van der Woude, J A D; Nair, S C; Custers, R J H; van Laar, J M; Kuchuck, N O; Lafeber, F P J G; Welsing, P M J

    2016-01-01

    In end-stage knee osteoarthritis the treatment of choice is total knee arthroplasty (TKA). An alternative treatment is knee joint distraction (KJD), suggested to postpone TKA. Several studies reported significant and prolonged clinical improvement of KJD. To make an appropriate decision regarding the position of this treatment, a cost-effectiveness and cost-utility analysis from healthcare perspective for different age and gender categories was performed. A treatment strategy starting with TKA and a strategy starting with KJD for patients of different age and gender was simulated. To extrapolate outcomes to long-term health and economic outcomes a Markov (Health state) model was used. The number of surgeries, QALYs, and treatment costs per strategy were calculated. Costs-effectiveness is expressed using the cost-effectiveness plane and cost-effectiveness acceptability curves. Starting with KJD the number of knee replacing procedures could be reduced, most clearly in the younger age categories; especially revision surgery. This resulted in the KJD strategy being dominant (more effective with cost-savings) in about 80% of simulations (with only inferiority in about 1%) in these age categories when compared to TKA. At a willingness to pay of 20.000 Euro per QALY gained, the probability of starting with KJD to be cost-effective compared to starting with a TKA was already found to be over 75% for all age categories and over 90-95% for the younger age categories. A treatment strategy starting with knee joint distraction for knee osteoarthritis has a large potential for being a cost-effective intervention, especially for the relatively young patient.

  11. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Directory of Open Access Journals (Sweden)

    Rasch Helmut

    2011-02-01

    Full Text Available Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA. Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10 and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p Results SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83% knees. Progression of patellofemoral OA (n = 11, loosening of the tibial (n = 3 and loosening of the femoral component (n = 2 were identified as the leading causes of pain after TKA. Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049 and in the femur (p = 0.051. Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p Conclusions SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.

  12. Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty (TKA) by Bade et al

    DEFF Research Database (Denmark)

    Mechlenburg, Inger; Skoffer, Birgit; Dalgas, Ulrik

    2017-01-01

    Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially no diffe......Recently, a paper entitled "Early High-Intensity Versus Low-Intensity Rehabilitation After Total Knee Arthroplasty: A Randomized Controlled Trial" was published in Arthritis Care Res by Bade et al. (1). We have read the paper with great interest and noted that the study shows essentially...

  13. Influence of Total Knee Arthroplasty on Gait Mechanics of the Replaced and Non-Replaced Limb During Stair Negotiation.

    Science.gov (United States)

    Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning

    2016-01-01

    This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Safety of retransfusing shed blood after local infiltration analgesia in total knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, B.J.; Pool, L.; Van Der Flier, R.; Stienstra, R.; in 't Veld, B.A.

    2012-01-01

    We investigated the safety of LIA (local infiltration analgesia) combined with retransfusion of drained blood. Total knee arthroplasty patients received two peri-articular injections during surgery followed by continuous infusion, both with ropivacaine (567 mg). Ropivacaine plasma concentrations

  15. FAST TRACK SURGERY IN TOTAL KNEE ARTHROPLASTY - A REVIEW.

    Directory of Open Access Journals (Sweden)

    Pencho Kosev

    2015-08-01

    Full Text Available The number of orthopedic surgeons who are convinced in the need for significant changes in planned total knee arthroplasty (TKA is increasing slowly and steadily. A new approach to pain control has been developed over the past 10-15 years, and the introduction of techniques to reduce perioperative stress, and the use of minimally invasive surgical techniques can help limit postoperative complications and shorten recovery time. This type of optimization is regarded as Fast-track Care program, where improved healing process is particularly useful to comorbid patients.

  16. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.

    Science.gov (United States)

    Patil, Shantanu; D'Lima, Darryl D; Fait, James M; Colwell, Clifford W

    2007-02-01

    The outcomes of knee arthroplasty have been shown to be affected by component alignment. Intramedullary and extramedullary alignment instrumentation are fairly effective for achieving the desired mean tibial component coronal alignment. However, there are outliers representing >3 degrees of varus or valgus alignment with respect to the anatomic tibial shaft axis. We measured the efficacy of a custom tibial planing device for reducing the outliers in tibial alignment. We designed a tibial planing tool in an effort to improve tibial alignment. In one cohort (100 knees), we used traditional intramedullary alignment instrumentation to make the tibial bone cut. In a second cohort (120 knees), we used intramedullary alignment instrumentation to make the cut and also used a custom tool to check the cut and to correct an inexact cut. Tibial tray alignment relative to the long axis of the tibial shaft was measured in the coronal and sagittal planes on postoperative radiographs. The target coronal alignment was 90 degrees with respect to the tibial shaft axis (with alignment). A total of 100 anteroposterior radiographs and sixty-five lateral radiographs were analyzed for the group that was treated with traditional instrumentation alone, and a total of 120 anteroposterior radiographs and fifty-five lateral radiographs were analyzed for the group that was treated with use of the custom tibial planing device. The mean coronal alignment of the tibial component was 89.5 degrees +/- 2.1 degrees in the group that was treated with traditional instrumentation alone and 89.6 degrees +/- 1.4 degrees in the group that was treated with use of the custom planing device. Although the mean coronal alignment was not significantly different, the number of outliers was substantially reduced when the custom planing device was used. All 120 components that had been aligned with use of the custom planing device were within 3 degrees of the target coronal alignment, compared with only eighty

  17. Effect of high-dose preoperative methylprednisolone on pain and recovery after total knee arthroplasty: a randomized, placebo-controlled trial

    DEFF Research Database (Denmark)

    Lunn, Troels; Kristensen, Billy Bjarne; Andersen, Lasse

    2011-01-01

    Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied.......Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied....

  18. Can computer assistance improve the clinical and functional scores in total knee arthroplasty?

    Science.gov (United States)

    Hernández-Vaquero, Daniel; Suarez-Vazquez, Abelardo; Iglesias-Fernandez, Susana

    2011-12-01

    Surgical navigation in TKA facilitates better alignment; however, it is unclear whether improved alignment alters clinical evolution and midterm and long-term complication rates. We determined the alignment differences between patients with standard, manual, jig-based TKAs and patients with navigation-based TKAs, and whether any differences would modify function, implant survival, and/or complications. We retrospectively reviewed 97 patients (100 TKAs) undergoing TKAs for minimal preoperative deformities. Fifty TKAs were performed with an image-free surgical navigation system and the other 50 with a standard technique. We compared femoral angle (FA), tibial angle (TA), and femorotibial angle (FTA) and determined whether any differences altered clinical or functional scores, as measured by the Knee Society Score (KSS), or complications. Seventy-three patients (75 TKAs) had a minimum followup of 8 years (mean, 8.3 years; range, 8-9.1 years). All patients included in the surgical navigation group had a FTA between 177° and 182º. We found no differences in the KSS or implant survival between the two groups and no differences in complication rates, although more complications occurred in the standard technique group (seven compared with two in the surgical navigation group). In the midterm, we found no difference in functional and clinical scores or implant survival between TKAs performed with and without the assistance of a navigation system. Level II, therapeutic study. See the Guidelines online for a complete description of levels of evidence.

  19. Adductor canal block versus femoral nerve block for analgesia after total knee arthroplasty

    DEFF Research Database (Denmark)

    Jaeger, Pia; Zaric, Dusanka; Fomsgaard, Jonna Storm

    2013-01-01

    Femoral nerve block (FNB), a commonly used postoperative pain treatment after total knee arthroplasty (TKA), reduces quadriceps muscle strength essential for mobilization. In contrast, adductor canal block (ACB) is predominately a sensory nerve block. We hypothesized that ACB preserves quadriceps...

  20. Clinical, nociceptive and psychological profiling to predict acute pain after total knee arthroplasty

    DEFF Research Database (Denmark)

    Luna, I E; Kehlet, H; Petersen, M A

    2017-01-01

    BACKGROUND: Pre-operative identification of high-pain responders for acute pain after total knee arthroplasty (TKA) could lead to targeted analgesic trials and individualized analgesic strategies to improve recovery and potentially reduce the risk of persistent post-surgical pain. The aim...

  1. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  2. Partial knee replacement

    Science.gov (United States)

    ... good range of motion in your knee. The ligaments in your knee are stable. However, most people with knee arthritis have a surgery called a total knee arthroplasty (TKA). Knee replacement is most often done in people age 60 ...

  3. In vitro wear assessments of fixed and mobile UHMWPE total knee replacement

    International Nuclear Information System (INIS)

    Affatato, Saverio; Bracco, Pierangiola; Sudanese, Alessandra

    2013-01-01

    Highlights: ► In this study we examined the wear behaviour of total knee UHMWPE menisci. ► We used two different knee designs: mobile and fixed menisci. ► We used a knee simulator and FTIR analyses to evaluate the wear behaviour. ► Our conclusions are that the two designs had a different wear behaviour. - Abstract: This work discusses the wear behaviour of two different ultra-high-molecular-weight-polyethylene tibial component designs. Mobile and fixed bearings were tested on a knee wear simulator for 5 million cycles using bovine calf serum as lubricant. We correlated the wear results with the chemical characterisation of the investigated materials: Fourier Transformed Infra Red Spectroscopy analyses, Differential Scanning Calorimetry and cross-link density measurements were used to assess the chemical features of this polyethylene. Mobile and fixed polyethylene inserts showed a different wear behaviour: the mobile designs components showed lower weight losses than the fixed components (109 ± 6 mg and 163 ± 80 mg, respectively). Significant statistical differences were observed in wear rate (P = 0.035, Kolmogorov–Smirnov Test for two samples). From a molecular point of view, typical radiation-induced oxidation profiles were observed in all the tested polyethylene samples, but the overall degradation was more significant in the fixed bearing inserts and this is likely to play a role on the wear performances

  4. Preoperative physiotherapy and short-term functional outcomes of primary total knee arthroplasty.

    Science.gov (United States)

    Mat Eil Ismail, Mohd Shukry; Sharifudin, Mohd Ariff; Shokri, Amran Ahmed; Ab Rahman, Shaifuzain

    2016-03-01

    Physiotherapy is an important part of rehabilitation following arthroplasty, but the impact of preoperative physiotherapy on functional outcomes is still being studied. This randomised controlled trial evaluated the effect of preoperative physiotherapy on the short-term functional outcomes of primary total knee arthroplasty (TKA). 50 patients with primary knee osteoarthritis who underwent unilateral primary TKA were randomised into two groups: the physiotherapy group (n = 24), whose patients performed physical exercises for six weeks immediately prior to surgery, and the nonphysiotherapy group (n = 26). All patients went through a similar physiotherapy regime in the postoperative rehabilitation period. Functional outcome assessment using the algofunctional Knee Injury and Osteoarthritis Outcome Score (KOOS) scale and range of motion (ROM) evaluation was performed preoperatively, and postoperatively at six weeks and three months. Both groups showed a significant difference in all algofunctional KOOS subscales (p 0.05). Significant differences were observed in the time-versus-treatment analysis between groups for the symptoms (p = 0.003) and activities of daily living (p = 0.025) subscales. No significant difference in ROM was found when comparing preoperative measurements and those at three months following surgery, as well as in time-versus-treatment analysis (p = 0.928). Six-week preoperative physiotherapy showed no significant impact on short-term functional outcomes (KOOS subscales) and ROM of the knee following primary TKA. Copyright: © Singapore Medical Association.

  5. FUNCTIONAL IMPROVEMENT UP TO SIX MONTHS AFTER TOTAL KNEE ARTHROPLASTY: MEASURED BY KNEE RANGE OF MOTION AND SELF-REPORTED QUESTIONNAIRE

    Directory of Open Access Journals (Sweden)

    Mirjana Kocić

    2015-12-01

    Full Text Available The primary aim of this study was to assess knee range of motion (ROM as well as patients’ reported pain, stiffness and function up to six months after total knee arthroplasty (TKA. The secondary aim was to analyze the extent to which knee ROM correlates with patient-rated outcome. A prospective study included 60 patients with primary TKA for osteorthritis, admitted at Physical Medicine and Rehabilitation Clinic from April 2009 to October 2014. The patients were evaluated at 4 time points: at admission and at discharge, as well as at follow-up at 3 and at 6 months after surgery. The outcome parameters included: active knee ROM, as well as pain, stiffness and function according to self reported Western Ontario and McMaster Universities Osteoarthritis (WOMAC questionnaire. Statistically highly significant improvement in flexion and extension was observed from admission to all other assessment time points (p<0.001. Also, statistically significant improvement of all three WOMAC subscales (pain, stiffness and function was found between all assessments points (p<0.001. According to values of Spearman correlation coefficient, there was significant negative correlation of flexion with all WOMAC subscales at all assessment points, whereas correlation of extension with any assessed outcome parameter was without significance. It can be concluded that in TKA patients all outcome measures improved significantly from admission to 6 months follow-up. Knee flexion ROM negatively and moderately to strongly correlated with pain, stiffness and function, whereas correlation of extension with any assessed outcome measure was without significance.

  6. Total artificial heart implantation in a young Marfan syndrome patient.

    Science.gov (United States)

    Rao, Prashant; Keenan, Jack B; Rajab, Taufiek K; Kim, Samuel; Smith, Richard; Amabile, Orazio; Khalpey, Zain

    2018-03-01

    Cardiovascular complications represent the leading cause of morbidity and mortality in patients with Marfan syndrome. Here, we describe a unique case where a total artificial heart was implanted in a young Marfan syndrome woman. A 22-year-old postpartum African American female with Marfan syndrome developed multiple severe valve dysfunction and biventricular failure that was refractory to medical management. She previously had a Bentall procedure for Type A aortic dissection and repair of a Type B dissection. We implanted a total artificial heart with a good outcome. Total artificial heart is a durable option for severe biventricular failure and multiple valvular dysfunction as a bridge to transplant in a young patient with Marfan syndrome.

  7. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  8. Flowtron foot-pumps for prevention of venous thromboembolism in total hip and knee replacement.

    Science.gov (United States)

    Pitto, Rocco P; Koh, Chuan K

    2015-03-01

    Mechanical prophylaxis with foot-pumps provides an interesting alternative to chemical agents in the prevention of venous thomboembolism following major orthopaedic surgery procedures. The aim of this prospective study was to assess efficacy and safety of the Flowtron(®) foot-pumps system following total hip and knee replacement. The foot pumps were used as main tool for prevention of thromboembolic events, in most cases in association with a variety of chemicals. The primary endpoint of the study was to assess the incidence of deep vein thrombosis and pulmonary embolism after total hip and knee replacement. The secondary endpoints included postoperative bleeding, swelling, bruising and wound ooze. 424 consecutive patients were included in the study. Symptomatic deep vein thrombosis was detected in 7 patients (1.6%). All symptomatic deep vein thromboses were detected after discharge before the six week follow-up clinic. Five non-fatal pulmonary embolisms occurred (1.2%). Only one patient presented a major wound bleeding (0.2%). The mean difference of swelling of thigh pre-versus postoperatively was only 22.8 mm. In conclusion, thromboembolism prophylaxis after total hip and knee replacement using Flowtron(®) foot-pumps as main prevention tool of an individualised protocol appears effective and safe. This is the first clinical report related to this popular brand of foot pumps.

  9. Post-Discharge Care Duration, Charges, and Outcomes Among Medicare Patients After Primary Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Ponnusamy, Karthikeyan E; Naseer, Zan; El Dafrawy, Mostafa H; Okafor, Louis; Alexander, Clayton; Sterling, Robert S; Khanuja, Harpal S; Skolasky, Richard L

    2017-06-07

    In April 2016, the U.S. Centers for Medicare & Medicaid Services initiated mandatory 90-day bundled payments for total hip and knee arthroplasty for much of the country. Our goal was to determine duration of care, 90-day charges, and readmission rates by discharge disposition and U.S. region after hip or knee arthroplasty. Using the 2008 Medicare Provider Analysis and Review database 100% sample, we identified patients who had undergone elective primary total hip or knee arthroplasty. We collected data on patient age, sex, comorbidities, U.S. Census region, discharge disposition, duration of care, 90-day charges, and readmission. Multivariate regression was used to assess factors associated with readmission (logistic) and charges (linear). Significance was set at p total hip arthroplasties were discharged to home (18%), home health care (34%), extended-care facilities (35%), and inpatient rehabilitation (13%); patients undergoing 329,233 total knee arthroplasties were discharged to home (21%), home health care (38%), extended-care facilities (31%), and inpatient rehabilitation (10%). Patients in the Northeast were more likely to be discharged to extended-care facilities or inpatient rehabilitation than patients in other regions. Patients in the West had the highest 90-day charges. Approximately 70% of patients were discharged home from extended-care facilities, whereas after inpatient rehabilitation, >50% of patients received home health care. Among those discharged to home, 90-day readmission rates were highest in the South (9.6%) for patients undergoing total hip arthroplasty and in the Midwest (8.7%) and the South (8.5%) for patients undergoing total knee arthroplasty. Having ≥4 comorbidities, followed by discharge to inpatient rehabilitation or an extended-care facility, had the strongest associations with readmission, whereas the region of the West and the discharge disposition to inpatient rehabilitation had the strongest association with higher charges

  10. Toward the Turkish National Registry System: A Prevalence Study of Total Knee Arthroplasty in Turkey.

    Science.gov (United States)

    Ceyhan, Erman; Gursoy, Safa; Akkaya, Mustafa; Ugurlu, Mahmut; Koksal, Ismet; Bozkurt, Murat

    2016-09-01

    The aim of this pilot study was to analyze the data obtained from a retrospective examination of the records of the existing reimbursement system and through the identification of gaps in the data to create a foundation for a reliable, descriptive national registry system for our country. The Social Security Institution Medical Messenger (MEDULA) records were scanned for the years 2010-2014, and the numbers of total knee arthroplasty applied for a diagnosis of gonarthrosis and the numbers of revision knee arthroplasty were recorded for the country in general. The patients were classified according to age, gender, and bilateral or unilateral surgery. The institution where the surgery was applied, the geographic region and the province were also recorded. A total of 283,400 primary and 9900 revision knee arthroplasty operations were applied in Turkey between 2010 and 2014. Numbers were recorded for each year, and there was found to be an increase between years. For primary knee arthroplasty, the female:male ratio was 67 of 33, and surgery was applied most often between the ages of 60-69 years. Both types of surgery were determined to have been applied most often in second-stage state hospitals. Geographically, both types of surgery were applied most in the Marmara region, with the highest frequency of primary knee arthroplasty in Istanbul and the highest frequency of revision surgery in Ankara. The data obtained from this study will contribute to the creation of the basis for a National Registry System and thereby define more scientific treatment approaches. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Results of infected total knee arthroplasty treated with arthroscopic debridement and continuous antibiotic irrigation system

    Directory of Open Access Journals (Sweden)

    Che-Wei Liu

    2013-01-01

    Conclusion: Arthroscopic debridement combined with continuous antibiotic irrigation and suction is an effective treatment for patients with acute presentation of late infected total knee arthroplasty.

  12. Knee Arthrodesis After Failure of Knee Arthroplasty

    DEFF Research Database (Denmark)

    Gottfriedsen, Tinne B; Morville Schrøder, Henrik; Odgaard, Anders

    2016-01-01

    BACKGROUND: Arthrodesis is considered a salvage procedure after failure of a knee arthroplasty. Data on the use of this procedure are limited. The purpose of this study was to identify the incidence, causes, surgical techniques, and outcomes of arthrodesis after failed knee arthroplasty...... in a nationwide population. METHODS: Data were extracted from the Danish Civil Registration System, the Danish National Patient Register, and the Danish Knee Arthroplasty Register. A total of 92,785 primary knee arthroplasties performed in Denmark from 1997 to 2013 were identified by linking the data using....... Differences in cumulative incidence were compared with the Gray test. RESULTS: A total of 164 of the 165 arthrodeses were performed for causes related to failed knee arthroplasty. The 15-year cumulative incidence of arthrodesis was 0.26% (95% confidence interval, 0.21% to 0.31%). The 5-year cumulative...

  13. Joint awareness after total knee arthroplasty is affected by pain and quadriceps strength.

    Science.gov (United States)

    Hiyama, Y; Wada, O; Nakakita, S; Mizuno, K

    2016-06-01

    There is a growing interest in the use of patient-reported outcomes to provide a more patient-centered view on treatment. Forgetting the artificial joint can be regarded as the goal in joint arthroplasty. The goals of the study were to describe changes in joint awareness in the artificial joint after total knee arthroplasty (TKA), and to determine which factors among pain, knee range of motion (ROM), quadriceps strength, and functional ability affect joint awareness after TKA. Patients undergoing TKA demonstrate changes in joint awareness and joint awareness is associated with pain, knee ROM, quadriceps strength, and functional ability. This prospective cohort study comprised 63 individuals undergoing TKA, evaluated at 1, 6, and 12 months postoperatively. Outcomes included joint awareness assessed using the Forgotten Joint Score (FJS), pain score, knee ROM, quadriceps strength, and functional ability. Fifty-eight individuals completed all postoperative assessments. All measures except for knee extension ROM improved from 1 to 6 months. However, there were no differences in any measures from 6 to 12 months. FJS was affected most greatly by pain at 1 month and by quadriceps strength at 6 and 12 months. Patients following TKA demonstrate improvements in joint awareness and function within 6 months after surgery, but reach a plateau from 6 to 12 months. Quadriceps strength could contribute to this plateau of joint awareness. Prospective cohort study, IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. [Research progress of larger flexion gap than extension gap in total knee arthroplasty].

    Science.gov (United States)

    Zhang, Weisong; Hao, Dingjun

    2017-05-01

    To summarize the progress of larger flexion gap than extension gap in total knee arthro-plasty (TKA). The domestic and foreign related literature about larger flexion gap than extension gap in TKA, and its impact factors, biomechanical and kinematic features, and clinical results were summarized. During TKA, to adjust the relations of flexion gap and extension gap is one of the key factors of successful operation. The biomechanical, kinematic, and clinical researches show that properly larger flexion gap than extension gap can improve both the postoperative knee range of motion and the satisfaction of patients, but does not affect the stability of the knee joint. However, there are also contrary findings. So adjustment of flexion gap and extension gap during TKA is still in dispute. Larger flexion gap than extension gap in TKA is a new joint space theory, and long-term clinical efficacy, operation skills, and related complications still need further study.

  15. No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

    Science.gov (United States)

    Minoda, Yukihide; Hata, Kanako; Iwaki, Hiroyoshi; Ikebuchi, Mitsuhiko; Hashimoto, Yusuke; Inori, Fumiaki; Nakamura, Hiroaki

    2014-03-01

    Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 μm in the case of oxidized zirconium and 0.6 ± 0.1 μm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. Therapeutic study, Level III.

  16. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...

  17. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  18. Evaluation of the relationship between anteroposterior translation of a posterior cruciate ligament-retaining total knee replacement and functional outcome.

    Science.gov (United States)

    Seah, R B; Pang, H N; Lo, N N; Chong, H C; Chin, P L; Chia, S L; Yeo, S J

    2012-10-01

    The success of total knee replacement (TKR) depends on optimal soft-tissue balancing, among many other factors. The objective of this study is to correlate post-operative anteroposterior (AP) translation of a posterior cruciate ligament-retaining TKR with clinical outcome at two years. In total 100 patients were divided into three groups based on their AP translation as measured by the KT-1000 arthrometer. Group 1 patients had AP translation  10 mm. Outcome assessment included range of movement of the knee, the presence of flexion contractures, hyperextension, knee mechanical axes and functional outcome using the Knee Society score, Oxford knee score and the Short-Form 36 questionnaire. At two years, patients in Group 2 reported significantly better Oxford knee scores than the other groups (p = 0.045). A positive correlation between range of movement and AP translation was noted, with patients in group 3 having the greatest range of movement (mean flexion: 117.9° (106° to 130°)) (p 10° (p = 0.01). In this study, the best outcome for cruciate-ligament retaining TKR was achieved in patients with an AP translation of 5 mm to 10 mm.

  19. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Directory of Open Access Journals (Sweden)

    van Jonbergen Hans-Peter W

    2012-06-01

    Full Text Available Abstract Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding.

  20. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    Science.gov (United States)

    2012-01-01

    Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding. PMID:22704638