WorldWideScience

Sample records for total insertion loss

  1. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  2. Low insertion loss SOI microring resonator integrated with nano-taper couplers

    DEFF Research Database (Denmark)

    Pu, Minhao; Frandsen, Lars Hagedorn; Ou, Haiyan

    2009-01-01

    We demonstrate a microring resonator working at TM mode integrated with nano-taper couplers with 3.6dB total insertion loss. The measured insertion loss of the nano-taper coupler was only 1.3dB for TM mode....

  3. Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Mikkel Rathsach; Winther, Nikolaj; Lind, Thomas

    2016-01-01

    Background and purpose - Backside wear of the polyethylene insert in total knee arthroplasty (TKA) can produce clinically significant levels of polyethylene debris, which can lead to loosening of the tibial component. Loosening due to polyethylene debris could theoretically be reduced in tibial...

  4. Global Drought Total Economic Loss Risk Deciles

    Data.gov (United States)

    National Aeronautics and Space Administration — Global Drought Total Economic Loss Risk Deciles is a 2.5 minute grid of global drought total economic loss risks. A process of spatially allocating Gross Domestic...

  5. Global Landslide Total Economic Loss Risk Deciles

    Data.gov (United States)

    National Aeronautics and Space Administration — Global Landslide Total Economic Loss Risk Deciles is a 2.5 minute grid of global landslide total economic loss risks. A process of spatially allocating Gross...

  6. Combined heart-kidney transplantation after total artificial heart insertion.

    Science.gov (United States)

    Ruzza, A; Czer, L S C; Ihnken, K A; Sasevich, M; Trento, A; Ramzy, D; Esmailian, F; Moriguchi, J; Kobashigawa, J; Arabia, F

    2015-01-01

    We present the first single-center report of 2 consecutive cases of combined heart and kidney transplantation after insertion of a total artificial heart (TAH). Both patients had advanced heart failure and developed dialysis-dependent renal failure after implantation of the TAH. The 2 patients underwent successful heart and kidney transplantation, with restoration of normal heart and kidney function. On the basis of this limited experience, we consider TAH a safe and feasible option for bridging carefully selected patients with heart and kidney failure to combined heart and kidney transplantation. Recent FDA approval of the Freedom driver may allow outpatient management at substantial cost savings. The TAH, by virtue of its capability of providing pulsatile flow at 6 to 10 L/min, may be the mechanical circulatory support device most likely to recover patients with marginal renal function and advanced heart failure. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Yohei Tanikake

    2016-12-01

    Full Text Available A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.

  8. Oxidised zirconium versus cobalt alloy bearing surfaces in total knee arthroplasty: 3D laser scanning of retrieved polyethylene inserts.

    Science.gov (United States)

    Anderson, F L; Koch, C N; Elpers, M E; Wright, T M; Haas, S B; Heyse, T J

    2017-06-01

    We sought to establish whether an oxidised zirconium (OxZr) femoral component causes less loss of polyethylene volume than a cobalt alloy (CoCr) femoral component in total knee arthroplasty. A total of 20 retrieved tibial inserts that had articulated with OxZr components were matched with 20 inserts from CoCr articulations for patient age, body mass index, length of implantation, and revision diagnosis. Changes in dimensions of the articular surfaces were compared with those of pristine inserts using laser scanning. The differences in volume between the retrieved and pristine surfaces of the two groups were calculated and compared. The loss of polyethylene volume was 122 mm 3 (standard deviation (sd) 87) in the OxZr group and 170 mm 3 (sd 96) in the CoCr group (p = 0.033). The volume loss in the OxZr group was also lower in the medial (72 mm 3 (sd 67) versus 92 mm 3 (sd 60); p = 0.096) and lateral (49 mm 3 (sd 36) versus 79 mm 3 (sd 61); p = 0.096) compartments separately, but these differences were not significant. Our results corroborate earlier findings from in vitro testing and visual retrieval analysis which suggest that polyethylene volume loss is lower with OxZr femoral components. Since both OxZr and CoCr are hard surfaces that would be expected to create comparable amounts of polyethylene creep, the differences in volume loss may reflect differences in the in vivo wear of these inserts. Cite this article: Bone Joint J 2017;99-B:793-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  9. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty

    OpenAIRE

    Tanikake, Yohei; Hayashi, Koji; Ogawa, Munehiro; Inagaki, Yusuke; Kawate, Kenji; Tomita, Tetsuya; Tanaka, Yasuhito

    2016-01-01

    A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed...

  10. Single phase and two-phase flow pressure losses through restrictions, expansions and inserts

    International Nuclear Information System (INIS)

    Glenat, P.; Solignac, P.

    1984-11-01

    We give a selection of methods to predict pressure losses through retrictions, expansions and inserts. In single phase flow, we give the classical method based on the one-dimensional momentum and mass balances. In two-phase flow, we propose the method given by Harshe et al. and an empirical approach suggested by Chisholm. We notice the distinction between long and short inserts depends upon wether or not the vena contracta lies within insert. Finally, we propose three correlations to calculate void fraction through the singularities which have been considered [fr

  11. Study of low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices.

    Science.gov (United States)

    Jiang, Hua; Lu, Wenke; Zhang, Guoan

    2013-07-01

    In this paper, we propose a low insertion loss and miniaturization wavelet transform and inverse transform processor using surface acoustic wave (SAW) devices. The new SAW wavelet transform devices (WTDs) use the structure with two electrode-widths-controlled (EWC) single phase unidirectional transducers (SPUDT-SPUDT). This structure consists of the input withdrawal weighting interdigital transducer (IDT) and the output overlap weighting IDT. Three experimental devices for different scales 2(-1), 2(-2), and 2(-3) are designed and measured. The minimum insertion loss of the three devices reaches 5.49dB, 4.81dB, and 5.38dB respectively which are lower than the early results. Both the electrode width and the number of electrode pairs are reduced, thus making the three devices much smaller than the early devices. Therefore, the method described in this paper is suitable for implementing an arbitrary multi-scale low insertion loss and miniaturization wavelet transform and inverse transform processor using SAW devices. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Original Article Blood Loss and Influencing Factors in Primary Total ...

    African Journals Online (AJOL)

    KIGZ

    aid the surgeon in the African region estimate the expected blood loss after total hip replacement. We conducted a study to quantify the blood loss following total hip arthroplasty and to determine the factors .... Hemoglobin European Overview (OSTHEO) study: blood management in elective knee and hip arthroplasty in ...

  13. A phylogenetic approach to total evaporative water loss in mammals.

    Science.gov (United States)

    Van Sant, Matthew J; Oufiero, Christopher E; Muñoz-Garcia, Agustí; Hammond, Kimberly A; Williams, Joseph B

    2012-01-01

    Maintaining appropriate water balance is a constant challenge for terrestrial mammals, and this problem can be exacerbated in desiccating environments. It has been proposed that natural selection has provided desert-dwelling mammals physiological mechanisms to reduce rates of total evaporative water loss. In this study, we evaluated the relationship between total evaporative water loss and body mass in mammals by using a recent phylogenetic hypothesis. We compared total evaporative water loss in 80 species of arid-zone mammals to that in 56 species that inhabit mesic regions, ranging in size from 4 g to 3,500 kg, to test the hypothesis that mammals from arid environments have lower rates of total evaporative water loss than mammals from mesic environments once phylogeny is taken into account. We found that arid species had lower rates of total evaporative water loss than mesic species when using a dichotomous variable to describe habitat (arid or mesic). We also found that total evaporative water loss was negatively correlated with the average maximum and minimum environmental temperature as well as the maximum vapor pressure deficit of the environment. Annual precipitation and the variable Q (a measure of habitat aridity) were positively correlated with total evaporative water loss. These results support the hypothesis that desert-dwelling mammals have lower rates of total evaporative water loss than mesic species after controlling for body mass and evolutionary relatedness regardless of whether categorical or continuous variables are used to describe habitat.

  14. Human local and total heat losses in different temperature.

    Science.gov (United States)

    Wang, Lijuan; Yin, Hui; Di, Yuhui; Liu, Yanfeng; Liu, Jiaping

    2016-04-01

    This study investigates the effects of operative temperature on the local and total heat losses, and the relationship between the heat loss and thermal sensation. 10 local parts of head, neck, chest, abdomen, upper arm, forearm, hand, thigh, leg and foot are selected. In all these parts, convection, radiation, evaporation, respiration, conduction and diffusion heat losses are analyzed when operative temperature is 23, 28, 33 and 37 °C. The local heat losses show that the radiation and convection heat losses are mainly affected by the area of local body, and the heat loss of the thigh is the most in the ten parts. The evaporation heat loss is mainly affected by the distribution of sweat gland, and the heat loss of the chest is the most. The total heat loss of the local body shows that in low temperature, the thigh, leg and chest have much heat loss, while in high temperature, the chest, abdomen, thigh and head have great heat loss, which are useful for clothing design. The heat losses of the whole body show that as the operative temperature increases, the radiation and convection heat losses decrease, the heat losses of conduction, respiration, and diffusion are almost constant, and the evaporation heat loss increases. By comparison, the heat loss ratios of the radiation, convection and sweat evaporation, are in agreement with the previous researches. At last, the formula about the heat loss ratio of convection and radiation is derived. It's useful for thermal comfort evaluation and HVAC (heating, ventilation and air conditioning) design. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Correlation between extension-block K-wire insertion angle and postoperative extension loss in mallet finger fracture.

    Science.gov (United States)

    Lee, S K; Kim, Y H; Moon, K H; Choy, W S

    2018-02-01

    Extension-block pinning represents a simple and reliable surgical technique. Although this procedure is commonly performed successfully, some patients develop postoperative extension loss. To date, the relationship between extension-block Kirschner wire (K-wire) insertion angle and postoperative extension loss in mallet finger fracture remains unclear. We aimed to clarify this relationship and further evaluate how various operative and non-operative factors affect postoperative extension loss after extension-block pinning for mallet finger fracture. A retrospective study was conducted to investigate a relationship between extension block K-wire insertion angle and postoperative extension loss. The inclusion criteria were: (1) a dorsal intra-articular fracture fragment involving 30% of the base of the distal phalanx with or without volar subluxation of the distal phalanx; and (2) block K-wire insertion angle and fixation angle of the distal interphalangeal (DIP) joint were assessed using lateral radiograph at immediate postoperative time. Postoperative extension loss was assessed by using lateral radiograph at latest follow-up. Extension-block K-wire insertion angle was defined as the acute angle between extension block K-wire and longitudinal axis of middle phalangeal head. DIP joint fixation angle was defined as the acute angle between the distal phalanx and middle phalanx longitudinal axes. Seventy-five patients were included. The correlation analysis revealed that extension-block K-wire insertion angle had a negative correlation with postoperative extension loss, whereas fracture size and time to operation had a positive correlation (correlation coefficient for extension block K-wire angle: -0.66, facture size: +0.67, time to operation: +0.60). When stratifying patients in terms of negative and positive fixation angle of the DIP joint, the independent t-test showed that mean postoperative extension loss is -3.67° and +4.54° (DIP joint fixation angles of block

  16. Loss of locality in gravitational correlators with a large number of insertions

    Science.gov (United States)

    Ghosh, Sudip; Raju, Suvrat

    2017-09-01

    We review lessons from the AdS/CFT correspondence that indicate that the emergence of locality in quantum gravity is contingent upon considering observables with a small number of insertions. Correlation functions, where the number of insertions scales with a power of the central charge of the CFT, are sensitive to nonlocal effects in the bulk theory, which arise from a combination of the effects of the bulk Gauss law and a breakdown of perturbation theory. To examine whether a similar effect occurs in flat space, we consider the scattering of massless particles in the bosonic string and the superstring in the limit, where the number of external particles, n, becomes very large. We use estimates of the volume of the Weil-Petersson moduli space of punctured Riemann surfaces to argue that string amplitudes grow factorially in this limit. We verify this factorial behavior through an extensive numerical analysis of string amplitudes at large n. Our numerical calculations rely on the observation that, in the large n limit, the string scattering amplitude localizes on the Gross-Mende saddle points, even though individual particle energies are small. This factorial growth implies the breakdown of string perturbation theory for n ˜(M/plE ) d -2 in d dimensions, where E is the typical individual particle energy. We explore the implications of this breakdown for the black hole information paradox. We show that the loss of locality suggested by this breakdown is precisely sufficient to resolve the cloning and strong subadditivity paradoxes.

  17. Traumatic Dislodgement of Tibial Polyethylene Insert after a High-Flex Posterior-Stabilized Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Juan Felix Astoul Bonorino

    2015-01-01

    Full Text Available Many pathologic entities can produce a painful total knee replacement (TKR that may lead to potential prosthetic failure. Polyethylene insert dissociation from the tibial baseplate has been described most frequently after mobile-bearing and cruciate-retaining TKRs. However, only 3 tibial insert dislocations in primary fixed-bearing High-Flex posterior-stabilized TKRs have been reported. We present a new case of tibial insert dislocation in a High-Flex model that shares similarities and differences with the cases reported, facilitating the analysis of the potential causes, which still remain undefined.

  18. Core dynamics analysis for reactivity insertion and loss of coolant flow tests using the HTTR

    International Nuclear Information System (INIS)

    Takamatsu, Kuniyoshi; Nakagawa, Shigeaki; Takeda, Tetsuaki

    2007-01-01

    The High Temperature engineering Test Reactor (HTTR) is a graphite-moderated and a gas-cooled reactor with a thermal power of 30 MW and a reactor outlet coolant temperature of 950degC (SAITO, 1994). Safety demonstration tests using the HTTR are in progress to verify its inherent safety features and improve the safety technology and design methodology for High-Temperature Gas-cooled Reactors (HTGRs) (TACHIBANA 2002) (NAKAGAWA 2004). The reactivity insertion test is one of the safety demonstration tests for the HTTR. This test simulates the rapid increase in the reactor power by withdrawing the control rod without operating the reactor power control system. In addition, the loss of coolant flow tests has been conducted to simulate the rapid decrease in the reactor power by tripping one, two or all out of three gas circulators. The experimental results have revealed the inherent safety features of HTGRs, such as the negative reactivity feedback effect. The numerical analysis code, which was named ACCORD (TAKAMATSU 2006), was developed to analyze the reactor dynamics including the flow behavior in the HTTR core. We used a conventional method, namely, a one-dimensional flow channel model and reactor kinetics model with a single temperature coefficient, taking into account the temperature changes in the core. However, a slight difference between the analytical and experimental results was observed. Therefore, we have modified this code to use a model with four parallel channels and twenty temperature coefficients in the core. Furthermore, we added another analytical model of the core for calculating the heat conduction between the fuel channels and the core in the case of the loss of coolant flow tests. This paper describes the validation results for the newly developed code using the experimental results of the reactivity insertion test as well as the loss of coolant flow tests by tripping one or two out of three gas circulators. Finally, the pre-analytical result of

  19. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    Science.gov (United States)

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  20. Total Blood Loss After Transfemoral Amputations Is Twice the Intraoperative Loss

    DEFF Research Database (Denmark)

    Wied, Christian; Tengberg, Peter T; Kristensen, Morten T

    2017-01-01

    INTRODUCTION: Underestimation of the actual blood loss in patients undergoing nontraumatic transfemoral amputation (TFA) can impact negatively on outcome in these often frail patients, with very limited physiological reserves. The primary aim of this study is to estimate the total blood loss (TBL...

  1. Secondary knee instability caused by fracture of the stabilizing insert in a dual-articular total knee

    DEFF Research Database (Denmark)

    Boesen, Morten P; Jensen, Tim Toftgaard; Husted, Henrik

    2004-01-01

    A case of a fractured polyethylene stabilizing insert causing secondary knee instability in a Dual-articular total knee arthroplasty (TKA) is presented. A 65-year-old woman who underwent surgery with a Dual-articular TKA 4 years earlier had a well-functioning prosthesis until a fall, after which......-articular knee....

  2. Protein Losses and Urea Nitrogen Underestimate Total Nitrogen Losses in Peritoneal Dialysis and Hemodialysis Patients.

    Science.gov (United States)

    Salame, Clara; Eaton, Simon; Grimble, George; Davenport, Andrew

    2018-04-28

    Muscle wasting is associated with increased mortality and is commonly reported in dialysis patients. Hemodialysis (HD) and peritoneal dialysis (PD) treatments lead to protein losses in effluent dialysate. We wished to determine whether changes in current dialysis practice had increased therapy-associated nitrogen losses. Cross-sectional cohort study. Measurement of total protein, urea and total nitrogen in effluent dialysate from 24-hour collections from PD patients, and during haemodiafiltration (HDF) and haemodialysis (HD) sessions. One hundred eight adult dialysis patients. Peritoneal dialysis, high-flux haemodialysis and haemodiafiltration. Total nitrogen and protein losses. Dialysate protein losses were measured in 68 PD and 40 HD patients. Sessional losses of urea (13.9 [9.2-21.1] vs. 4.8 [2.8-7.8] g); protein (8.6 [7.2-11.1] vs. 6.7 [3.9-11.1] g); and nitrogen (11.5 [8.7-17.7] vs. 4.9 [2.6-9.5] g) were all greater for HD than PD, P losses were lower with HD 25.9 (21.5-33.4) versus 46.6 (27-77.6) g/week, but nitrogen losses were similar. We found no difference between high-flux HD and HDF: urea (13.5 [8.8-20.6] vs. 15.3 [10.5-25.5] g); protein (8.8 [7.3-12.2] vs. 7.6 [5.8-9.0] g); and total nitrogen (11.6 [8.3-17.3] vs. 10.8 [8.9-22.5] g). Urea nitrogen (UN) only accounted for 45.1 (38.3-51.0)% PD and 63.0 (55.3-62.4)% HD of total nitrogen losses. Although sessional losses of protein and UN were greater with HD, weekly losses were similar between modalities. We found no differences between HD and HDF. However, total nitrogen losses were much greater than the combination of protein and UN, suggesting greater nutritional losses with dialysis than previously reported. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  3. Decline of Low-Frequency Hearing in People With Ski-Slope Hearing Loss; Implications for Electrode Array Insertion.

    Science.gov (United States)

    Schuurbiers, Jasper; Dingemanse, Gertjan; Metselaar, Mick

    2017-12-01

    The decline of low-frequency hearing in people with ski-slope hearing loss varies and might depend on etiology. People with ski-sloping hearing loss might benefit from cochlear implantation with preservation of residual hearing. To reduce the risk of losing low-frequency hearing after implantation, the electrode-array can be inserted partially up to the desired frequency. That, however, obstructs electrical stimulation of lower frequencies. To decide between complete or partial insertion, knowledge regarding the natural decline of low-frequency hearing is helpful. Patients with at least two ski-slope audiograms over time were selected. We calculated progression at lower frequencies for 320 patients. Etiologies for hearing loss were retrieved from medical records. Progression of hearing loss was analyzed separately for patients with uni- and bilateral hearing losses. Relative progression of hearing loss was obtained by comparing progression to a reference group. Average progression of PTA was 1.73 dB/yr and was not significantly different in the bilateral and unilateral group. Etiologies that did not show significantly more progression compared with the reference group could be identified as single or short-lasting pathologic events, whereas long-lasting conditions had significant more progression of PTA. Patients with a ski-slope hearing loss that was caused by a single or short-lasting event have low progression rate and are viable for partial insertion to minimize the risk of damaging residual low-frequency hearing. In the absence of such an event, complete insertion should be considered because faster than normal deterioration of low-frequency hearing over time will probably limit the advantage of preservation of residual hearing.

  4. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    Science.gov (United States)

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Normal Incidence of Sound Transmission Loss of a Double-Leaf Partition Inserted with a Microperforated Panel

    Directory of Open Access Journals (Sweden)

    A. Putra

    2013-01-01

    Full Text Available A double-leaf partition in engineering structures has been widely applied for its advantages, that is, in terms of its mechanical strength as well as its lightweight property. In noise control, the double-leaf also serves as an effective noise barrier. Unfortunately at low frequency, the sound transmission loss reduces significantly due to the coupling between the panels and the air between them. This paper studies the effect of a microperforated panel (MPP inserted inside a double-leaf partition on the sound transmission loss performance of the system. The MPP insertion is proposed to provide a hygienic double-leaf noise insulator replacing the classical abrasive porous materials between the panels. It is found that the transmission loss improves at the troublesome mass-air-mass resonant frequency if the MPP is located closer to the solid panel. The mathematical model is derived for normal incidence of acoustic loading.

  6. Normal Incidence of Sound Transmission Loss of a Double-Leaf Partition Inserted with a Microperforated Panel

    OpenAIRE

    Putra, A.; Ismail, A. Y.; Ramlan, R.; Ayob, Md. R.; Py, M. S.

    2013-01-01

    A double-leaf partition in engineering structures has been widely applied for its advantages, that is, in terms of its mechanical strength as well as its lightweight property. In noise control, the double-leaf also serves as an effective noise barrier. Unfortunately at low frequency, the sound transmission loss reduces significantly due to the coupling between the panels and the air between them. This paper studies the effect of a microperforated panel (MPP) inserted inside a double-leaf part...

  7. Satisfactory Short-Term Results of Navigation-Assisted Gap-Balancing Total Knee Arthroplasty Using Ultracongruent Insert.

    Science.gov (United States)

    Yoon, Jung-Ro; Yang, Jae-Hyuk

    2018-03-01

    The use of highly conforming ultracongruent (UC) polyethylene insert is bone-preserving and became a relatively common alternative to the conventional posterior stabilized total knee arthroplasty (TKA) design. The purpose of this study was to analyze the short-term clinical and radiologic results of UC insert TKA using the navigation-assisted gap-balancing technique. Two hundred thirty-three knees were operated with a mean follow-up period of 8.1 years (minimum of 5 years). Radiologic and clinical outcomes were assessed before operation and at latest follow-up using the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index score. For statistical analysis, paired sample t-test and analysis of variance were used. Significance was considered as P satisfactory short-term outcome. Strict gap-balancing technique using the offset-type-force-controlled-spreader-system aided in the satisfactory results. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Epsilon Aminocaproic Acid to Reduce Blood Loss and Transfusion After Total Hip and Total Knee Arthroplasty.

    Science.gov (United States)

    Hobbs, Juliann C; Welsby, Ian J; Green, Cynthia L; Dhakal, Ishwori B; Wellman, Samuel S

    2018-01-01

    Total hip and knee arthroplasty (THA and TKA) are associated with significant blood loss and some patients require postoperative blood transfusion. While tranexamic acid has been studied extensively among this population, we tested the hypothesis that epsilon aminocaproic acid (EACA) can reduce blood loss and transfusion after joint arthroplasty. In April 2014, our Veterans Affairs Medical Center introduced a protocol to administer EACA during THA and TKA. No antifibrinolytics were used previously. We retrospectively compared blood loss and incidence of transfusion among patients who underwent primary arthroplasty in the year before standardized administration of EACA with patients having the same procedures the following year. Blood loss was measured as delta hemoglobin (preoperative hemoglobin - hemoglobin on postoperative day 1). All patients undergoing primary THA or TKA were included. Patients having revision surgery were excluded. We identified 185 primary arthroplasty patients from the year before and 184 from the year after introducing the EACA protocol. There were no changes in surgical technique or attending surgeons during this period. Delta hemoglobin was significantly lower in the EACA group (2.7 ± 0.8 mg/dL) compared to the control group (3.4 ± 1.1 mg/dL) (P blood transfusion was also significantly lower in the EACA group (2.7%) compared to the control group (25.4%) (P transfusion following introduction of the EACA protocol in patients undergoing primary arthroplasty. EACA offers a lower cost alternative to TXA for reducing blood loss and transfusion in this population. Published by Elsevier Inc.

  9. 'Shrink' losses in commercially sized corn silage piles: Quantifying total losses and where they occur.

    Science.gov (United States)

    Robinson, P H; Swanepoel, N; Heguy, J M; Price, T; Meyer, D M

    2016-01-15

    Silage 'shrink' (i.e., loss of fresh chopped crop between ensiling and feedout) represents a nutrient loss which can degrade air quality as volatile carbon compounds, degrade surface waterways due to seepage, or degrade aquifers due to seepage. Virtually no research has documented shrink in large silage piles. The term 'shrink' is often ill defined, but can be expressed as losses of wet weight (WW), oven dry matter (oDM), and oDM corrected for volatiles lost in the drying oven (vcoDM). Corn silage piles (4 wedge, 2 rollover/wedge, 1 bunker) from 950 to 12,204 tonnes as built, on concrete (4), soil (2) and a combination (1) in California's San Joaquin Valley, using a bacterial inoculant, covered within 24 h with an oxygen barrier inner film and black/white outer plastic, fed out using large front end loaders through an electronic feed tracking system, and from the 2013 crop year, were used. Shrink as WW, oDM and vcoDM were 90±17, 68±18 and 28±21 g/kg, suggesting that much WW shrink is water and much oDM shrink is volatiles lost during analytical oven drying. Most shrink occurred in the silage mass with losses from exposed silage faces, as well as between exposed face silage removal and the total mixed ration mixer, being low. Silage bulk density, exposed silage face management and face use rate did not have obvious impacts on any shrink measure, but age of the silage pile during silage feedout impacted shrink losses ('older' silage piles being higher), but most strongly for WW shrink. Real shrink losses (i.e., vcoDM) of large well managed corn silage piles are low, the exposed silage face is a small portion of losses, and many proposed shrink mitigations appeared ineffective, possibly because shrink was low overall and they are largely directed at the exposed silage face. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. SOUND TRANSMISSION LOSS OF A DOUBLE-LEAF PARTITION WITH MICRO-PERFORATED PLATE INSERTION UNDER DIFFUSE FIELD INCIDENCE

    Directory of Open Access Journals (Sweden)

    A. Putra

    2013-06-01

    Full Text Available In noise control applications, a double-leaf partition has been applied widely as a lightweight structure for noise insulation, such as in car doors, train bodies, and aircraft fuselages. Unfortunately, the insulation performance deteriorates significantly at mass-air-mass resonance due to coupling between the panels and the air in the gap. This paper investigates the effect of a micro-perforated panel (MPP, inserted in the conventional double-panel partition, on sound transmission loss at troublesome resonant frequencies. It is found that the transmission loss improves at this resonance if the MPP is located at a distance of less than half that of the air gap. A mathematical model is derived for the diffuse field incidence of acoustic loading.

  11. Directly UV written silica-on-silicon planar waveguides with low insertion loss

    DEFF Research Database (Denmark)

    Zauner, Dan; Svalgaard, Mikael; Kristensen, Martin

    1998-01-01

    in waveguide geometry, and excellent control of the refractive index step. Direct UV writing of waveguides became a realistic alternative to other fabrication methods when propagation losses below 0.2 dB/cm were reported in single-mode waveguides. However, the coupling loss to optical fibers remained high......, typically 1.8 dB/facet, which is significantly more than that obtained with other techniques. In this paper we present results in which the coupling loss to optical fibers has been lowered substantially. In addition, the glass photosensitivity has been increased, thus permitting shorter fabrication times......The photosensitive properties of germanosilica may be utilized to directly induce waveguide patterns into thin-film structures using ultraviolet (UV) light. The advantages of fabricating planar waveguides with UV light include the absence of photolithography and reactive ion etching, flexibility...

  12. The independent loss model with ordered insertions for the evolution of CRISPR spacers.

    Science.gov (United States)

    Baumdicker, F; Huebner, A M I; Pfaffelhuber, P

    2018-02-01

    Today, the CRISPR (clustered regularly interspaced short palindromic repeats) region within bacterial and archaeal genomes is known to encode an adaptive immune system. We rely on previous results on the evolution of the CRISPR arrays, which led to the ordered independent loss model, introduced by Kupczok and Bollback (2013). When focusing on the spacers (between the repeats), new elements enter a CRISPR array at rate θ at the leader end of the array, while all spacers present are lost at rate ρ along the phylogeny relating the sample. Within this model, we compute the distribution of distances of spacers which are present in all arrays in a sample of size n. We use these results to estimate the loss rate ρ from spacer array data for n=2 and n=3. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Ethamsylate and blood loss in total hip replacement.

    Science.gov (United States)

    Keith, I

    1979-01-01

    Nineteen consecutive patients undergoing total hip replacement under epidural anaesthesia were randomly divided into two groups. The treatment group received 1000 mg of ethamsylate intravenously before induction of anaesthesia. Blood lost during surgery was measured by a colorimetric technique. Closed suction drains were used and all blood lost after operation collected for measurement. Ethamsylate did not decrease the average volumes of blood lost during or after the operation. Neither did it reduce the requirements for blood transfusion. Although there were no side-effects attributable to ethamyslate, there seems to be no indication for its use in total hip replacement under epidural anaesthesia.

  14. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  15. The Effect of Temperature Dependence of AC Losses in a Bi-2223/Ag Insert of an 8-T Superconducting Magnet

    DEFF Research Database (Denmark)

    Wang, Lei; Wang, Qiuliang; Wang, Hui

    2016-01-01

    A conduction-cooled split-gap superconducting magnet system with a center field of 8 T has been designed and fabricated in the Institute of Electrical Engineering, Chinese Academy of Sciences. The system consists of two Bi-2223/Ag coils and six NbTi coils. Due to a large aspect ratio of the high-...... in the second case. Hence, it is a good way to reduce the ac losses by changing the charging sequences of the Bi-2223/Ag and NbTi cols. Afterward, the calculated results are compared with the experimental data, and they show a good agreement.......A conduction-cooled split-gap superconducting magnet system with a center field of 8 T has been designed and fabricated in the Institute of Electrical Engineering, Chinese Academy of Sciences. The system consists of two Bi-2223/Ag coils and six NbTi coils. Due to a large aspect ratio of the high......-temperature superconducting tape, there will be large ac losses when the magnet is ramped up and down. An accurate estimation of the total ac losses in the high-temperature superconducting coils is essential for the cryogenic system design. In the Bi-2223/Ag coils, the total ac losses mainly originate from two parts: One...

  16. Relationship between product demand, tibial polyethylene insert shelf age, and total knee arthroplasty survival: retrospective review of total knees of one design.

    Science.gov (United States)

    Urban, Joshua A; Collier, Matthew B; Engh, C Anderson; Engh, Gerard A

    2006-04-01

    Shelf aging of gamma-irradiated-in-air polyethylene tibial components has been associated with increased articular surface wear and an elevated risk for revision. Nine hundred fifty cruciate-retaining inserts of one design were implanted between 1987 and 1996 (shelf age, 1.0 +/- 1.2 years). Less frequently used inserts (smallest/largest sizes, thicker thicknesses, supplemental articular constraint) had longer shelf ages (means ranged from 1.2 to 2.6 years). Survival analysis showed that shelf age (P product demand and can be of aid when diagnosing the painful knee.

  17. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    Science.gov (United States)

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  18. ‘Shrink’ losses in commercially sized corn silage piles: Quantifying total losses and where they occur

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P.H.; Swanepoel, N.; Heguy, J.M.; Price, T.; Meyer, D.M., E-mail: phrobinson@ucdavis.edu [Department of Animal Science, UCCE Stanislaus, San Joaquin & Merced Counties, University of California, Davis, CA 95616 (United States)

    2016-01-15

    Silage ‘shrink’ (i.e., loss of fresh chopped crop between ensiling and feedout) represents a nutrient loss which can degrade air quality as volatile carbon compounds, degrade surface waterways due to seepage, or degrade aquifers due to seepage. Virtually no research has documented shrink in large silage piles. The term ‘shrink’ is often ill defined, but can be expressed as losses of wet weight (WW), oven dry matter (oDM), and oDM corrected for volatiles lost in the drying oven (vcoDM). Corn silage piles (4 wedge, 2 rollover/wedge, 1 bunker) from 950 to 12,204 tonnes as built, on concrete (4), soil (2) and a combination (1) in California's San Joaquin Valley, using a bacterial inoculant, covered within 24 h with an oxygen barrier inner film and black/white outer plastic, fed out using large front end loaders through an electronic feed tracking system, and from the 2013 crop year, were used. Shrink as WW, oDM and vcoDM were 90 ± 17, 68 ± 18 and 28 ± 21 g/kg, suggesting that much WW shrink is water and much oDM shrink is volatiles lost during analytical oven drying. Most shrink occurred in the silage mass with losses from exposed silage faces, as well as between exposed face silage removal and the total mixed ration mixer, being low. Silage bulk density, exposed silage face management and face use rate did not have obvious impacts on any shrink measure, but age of the silage pile during silage feedout impacted shrink losses (‘older’ silage piles being higher), but most strongly for WW shrink. Real shrink losses (i.e., vcoDM) of large well managed corn silage piles are low, the exposed silage face is a small portion of losses, and many proposed shrink mitigations appeared ineffective, possibly because shrink was low overall and they are largely directed at the exposed silage face. - Highlights: • Corn silage piles were used to measure ‘shrink’ from construction to feedout • Shrink was wet weight, dry weight (oDM) and oDM volatiles corrected

  19. An Evaluation of Intra‑ and Post‑operative Blood Loss in Total Hip ...

    African Journals Online (AJOL)

    2017-05-18

    May 18, 2017 ... Results: The mean intra‑ and post‑operative blood losses were 1222.7 ... To evaluate blood loss after total hip replacement. 2. To evaluate the .... 12.3. 4.2. 0.1. Median. 400.0. 150.0. 20.0. 3.0. Mode. 400.0. 100.0. 0.0. 3.0. SD.

  20. Eddy current and total power loss separation in the iron-phosphate-polyepoxy soft magnetic composites

    International Nuclear Information System (INIS)

    Taghvaei, A.H.; Shokrollahi, H.; Janghorban, K.; Abiri, H.

    2009-01-01

    This work investigates the magnetic properties of iron-phosphate-polyepoxy soft magnetic composite materials. FTIR spectra, EDX analysis, distribution maps, X-ray diffraction pattern and density measurements show that the particles surface layer contains a thin layer of nanocrystalline/amorphous phosphate with high coverage of powders surface. In this paper, a formula for calculating the eddy current loss and total loss components by loss separation method is presented and finally the different parts of power losses are calculated. The results show that, the contribution of eddy current in the bulk material for single coating layer (k b = 0.18) is higher in comparison with double coating layer (k b = 0.09). Moreover, iron-phosphate-polyepoxy composites (P = 0.000004f 2 ) have lower power loss in comparison with iron-phosphate composites (P = 0.00002f 2 ).

  1. Animal board invited review: Dairy cow lameness expenditures, losses and total cost.

    Science.gov (United States)

    Dolecheck, K; Bewley, J

    2018-03-20

    Lameness is one of the most costly dairy cow diseases, yet adoption of lameness prevention strategies remains low. Low lameness prevention adoption might be attributable to a lack of understanding regarding total lameness costs. In this review, we evaluated the contribution of different expenditures and losses to total lameness costs. Evaluated expenditures included labor for treatment, therapeutic supplies, lameness detection and lameness control and prevention. Evaluated losses included non-saleable milk, reduced milk production, reduced reproductive performance, increased animal death, increased animal culling, disease interrelationships, lameness recurrence and reduced animal welfare. The previous literature on total lameness cost estimates was also summarized. The reviewed studies indicated that previous estimates of total lameness costs are variable and inconsistent in the expenditures and losses they include. Many of the identified expenditure and loss categories require further research to accurately include in total lameness cost estimates. Future research should focus on identifying costs associated with specific lameness conditions, differing lameness severity levels, and differing stages of lactation at onset of lameness to provide better total lameness cost estimates that can be useful for decision making at both the herd and individual cow level.

  2. Reduced Membrane Insertion of CLC-K by V33L Barttin Results in Loss of Hearing, but Leaves Kidney Function Intact

    Directory of Open Access Journals (Sweden)

    Hua Tan

    2017-05-01

    Full Text Available In the mammalian ear, transduction of sound stimuli is initiated by K+ entry through mechano-sensitive channels into inner hair cells. K+ entry is driven by a positive endocochlear potential that is maintained by the marginal cell layer of the stria vascularis. This process requires basolateral K+ import by NKCC1 Na+−2Cl−−K+ co-transporters as well as Cl− efflux through ClC-Ka/barttin or ClC-Kb/barttin channels. Multiple mutations in the gene encoding the obligatory CLC-K subunit barttin, BSND, have been identified in patients with Bartter syndrome type IV. These mutations reduce the endocochlear potential and cause deafness. As CLC-K/barttin channels are also expressed in the kidney, patients with Bartter syndrome IV typically also suffer from salt-wasting hyperuria and electrolyte imbalances. However, there was a single report on a BSND mutation that resulted only in deafness, but not kidney disease. We herein studied the functional consequences of another recently discovered BSND mutation that predicts exchange of valine at position 33 by leucine. We combined whole-cell patch clamp, confocal microscopy and protein biochemistry to analyze how V33L affects distinct functions of barttin. We found that V33L reduced membrane insertion of CLC-K/barttin complexes without altering unitary CLC-K channel function. Our findings support the hypothesis of a common pathophysiology for the selective loss of hearing due to an attenuation of the total chloride conductance in the stria vascularis while providing enough residual function to maintain normal kidney function.

  3. The Effect of Malrotation of Tibial Component of Total Knee Arthroplasty on Tibial Insert during High Flexion Using a Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Kei Osano

    2014-01-01

    Full Text Available One of the most common errors of total knee arthroplasty procedure is a malrotation of tibial component. The stress on tibial insert is closely related to polyethylene failure. The objective of this study is to analyze the effect of malrotation of tibial component for the stress on tibial insert during high flexion using a finite element analysis. We used Stryker NRG PS for analysis. Three different initial conditions of tibial component including normal, 15° internal malrotation, and 15° external malrotation were analyzed. The tibial insert made from ultra-high-molecular-weight polyethylene was assumed to be elastic-plastic while femoral and tibial metal components were assumed to be rigid. Four nonlinear springs attached to tibial component represented soft tissues around the knee. Vertical load was applied to femoral component which rotated from 0° to 135° while horizontal load along the anterior posterior axis was applied to tibial component during flexion. Maximum equivalent stresses on the surface were analyzed. Internal malrotation caused the highest stress which arose up to 160% of normal position. External malrotation also caused higher stress. Implanting prosthesis in correct position is important for reducing the risk of abnormal wear and failure.

  4. Decisions with Uncertain Consequences-A Total Ordering on Loss-Distributions.

    Science.gov (United States)

    Rass, Stefan; König, Sandra; Schauer, Stefan

    2016-01-01

    Decisions are often based on imprecise, uncertain or vague information. Likewise, the consequences of an action are often equally unpredictable, thus putting the decision maker into a twofold jeopardy. Assuming that the effects of an action can be modeled by a random variable, then the decision problem boils down to comparing different effects (random variables) by comparing their distribution functions. Although the full space of probability distributions cannot be ordered, a properly restricted subset of distributions can be totally ordered in a practically meaningful way. We call these loss-distributions, since they provide a substitute for the concept of loss-functions in decision theory. This article introduces the theory behind the necessary restrictions and the hereby constructible total ordering on random loss variables, which enables decisions under uncertainty of consequences. Using data obtained from simulations, we demonstrate the practical applicability of our approach.

  5. Decisions with Uncertain Consequences-A Total Ordering on Loss-Distributions.

    Directory of Open Access Journals (Sweden)

    Stefan Rass

    Full Text Available Decisions are often based on imprecise, uncertain or vague information. Likewise, the consequences of an action are often equally unpredictable, thus putting the decision maker into a twofold jeopardy. Assuming that the effects of an action can be modeled by a random variable, then the decision problem boils down to comparing different effects (random variables by comparing their distribution functions. Although the full space of probability distributions cannot be ordered, a properly restricted subset of distributions can be totally ordered in a practically meaningful way. We call these loss-distributions, since they provide a substitute for the concept of loss-functions in decision theory. This article introduces the theory behind the necessary restrictions and the hereby constructible total ordering on random loss variables, which enables decisions under uncertainty of consequences. Using data obtained from simulations, we demonstrate the practical applicability of our approach.

  6. Combined Intra-Articular and Intravenous Tranexamic Acid Reduces Blood Loss in Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Nielsen, Christian Skovgaard; Jans, Øivind; Ørsnes, Thue

    2016-01-01

    BACKGROUND: In total knee arthroplasty, both intravenous (IV) and intra-articular (IA) administration of tranexamic acid (TXA) have been shown to reduce blood loss in several randomized controlled trials, although routine use of systemic TXA is considerably more common. However, to our knowledge...

  7. Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee

    2017-08-01

    Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.

  8. Reconciliation of Halogen-Induced Ozone Loss with the Total-Column Ozone Record

    Science.gov (United States)

    Shepherd, T. G.; Plummer, D. A.; Scinocca, J. F.; Hegglin, M. I.; Fioletov, V. E.; Reader, M. C.; Remsberg, E.; von Clarmann, T.; Wang, H. J.

    2014-01-01

    The observed depletion of the ozone layer from the 1980s onwards is attributed to halogen source gases emitted by human activities. However, the precision of this attribution is complicated by year-to-year variations in meteorology, that is, dynamical variability, and by changes in tropospheric ozone concentrations. As such, key aspects of the total-column ozone record, which combines changes in both tropospheric and stratospheric ozone, remain unexplained, such as the apparent absence of a decline in total-column ozone levels before 1980, and of any long-term decline in total-column ozone levels in the tropics. Here we use a chemistry-climate model to estimate changes in halogen-induced ozone loss between 1960 and 2010; the model is constrained by observed meteorology to remove the eects of dynamical variability, and driven by emissions of tropospheric ozone precursors to separate out changes in tropospheric ozone. We show that halogen-induced ozone loss closely followed stratospheric halogen loading over the studied period. Pronounced enhancements in ozone loss were apparent in both hemispheres following the volcanic eruptions of El Chichon and, in particular, Mount Pinatubo, which significantly enhanced stratospheric aerosol loads. We further show that approximately 40% of the long-term non-volcanic ozone loss occurred before 1980, and that long-term ozone loss also occurred in the tropical stratosphere. Finally, we show that halogeninduced ozone loss has declined by over 10% since stratospheric halogen loading peaked in the late 1990s, indicating that the recovery of the ozone layer is well underway.

  9. Improvement of insertion loss and quality factor of flexural plate-wave-based alpha-fetoprotein biosensor using groove-type reflective grating structures

    Science.gov (United States)

    Lin, Chang-Yu; Huang, I.-Yu; Lan, Je-Wei

    2013-01-01

    Conventional flexural plate-wave (FPW) transducers have limited applications in biomedical sensing due to their disadvantages such as high insertion loss and low quality factor. To overcome these shortcomings, we propose a FPW transducer on a low phase velocity insulator membrane (5-μm-thick SiO2) with a novel groove-type reflective grating structure design. Additionally, a cystamine self-assembly monolayer and a glutaraldehyde cross-linking layer are implemented on the backside of the FPW device to immobilize alpha-fetoprotein (AFP) antibody. A FPW-based AFP biosensor with low detection limit (5 ng/mL) can be achieved and used to measure the extreme low concentration of AFP antigen in human serum for early detection of hepatocellular carcinoma. The proposed FPW-based AFP biosensor also demonstrates a very high quality factor (206), low insertion loss (-40.854 dB), low operating frequency (6.388 MHz), and high sensing linearity (90.7%).

  10. Preoperative methylprednisolone does not reduce loss of knee-extension strength after total knee arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Viktoria; Bandholm, Thomas Q; Zilmer, Camilla K

    2017-01-01

    tests, rescue analgesic requirements, and plasma C-reactive protein (CRP) changes. Results - 61 patients completed the follow-up. The loss in quadriceps muscle strength was similar between groups; group MP 1.04 (0.22-1.91) Nm/kg (-89%) vs. group C 1.02 (0.22-1.57) Nm/kg (-88%). Also between......-265) mg/L (p loss of knee-extension strength or other functional outcomes at discharge after fast-track TKA despite a reduced systemic inflammatory response.......Background and purpose - Patients undergoing total knee arthroplasty (TKA) face challenges related to postoperative reduction in knee-extension strength. We evaluated whether inhibition of the inflammatory response by a single preoperative dose of methylprednisolone (MP) reduces the pronounced loss...

  11. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  12. Tolerance to bovine clinical mastitis: Total, direct, and indirect milk losses.

    Science.gov (United States)

    Detilleux, J

    2018-04-01

    The objectives of this paper were to estimate direct and indirect milk losses associated with mastitis. Indirect losses, linked to indirect tolerance, are mediated by the increase in milk somatic cell count (SCC) in response to bacterial infection. Direct losses, linked to weak direct tolerance, are not mediated by the increase in SCC. So far, studies have evaluated milk loss associated with clinical mastitis without considering both components, which may lead to biased estimates of their sum; that is, the total loss in milk. A total of 43,903 test-day records on milk and SCC from 3,716 cows and 5,858 lactations were analyzed with mediation mixed models and health trajectories to estimate the amount of direct, indirect, and total milk losses after adjustment for known and potentially unmeasured (sensitivity analyses) confounding factors. Estimates were formalized under the counterfactual causal theory of causation. In this study, milk losses were mostly mediated by an increase in SCC. They were highest in the first month of lactation, when SCC were highest. Milk losses were estimated at 0.5, 0.8, and 1.1 kg/d in first, second, and third and greater parity, respectively. Two phases described how changes in milk were associated with changes in SCC: on average, one occurred before and one after the day preceding the clinical diagnosis. In both phases, changes in milk were estimated at 1 mg/d per 10 3 cells/mL. After adjusting for known confounders, cow effect accounted for 20.7 and 64.2% of the variation in milk in the first and second phases, respectively. This suggests that deviations from the resilient path were highest during the second phase of inflammation and that selection for cows more tolerant to mastitis is feasible. As discussed herein, epigenetic regulation of macrophage polarization may contribute to the variation in milk observed in the second phase. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position.

    Science.gov (United States)

    Brodt, Steffen; Nowack, Dimitri; Jacob, Benjamin; Krakow, Linda; Windisch, Christoph; Matziolis, Georg

    2017-09-01

    Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup. Strong traction caused by retractors leads to iatrogenic pelvic lift and can thus be partly responsible for cup malpositioning. The objective of this study was to investigate such factors that influence pelvic lift. The dynamic movement of the pelvis was measured during implantation of THA in 67 patients. This was done by measuring the acceleration using the SensorLog app on a smartphone. At its maximum, the pelvis was lifted by an average of 6.7°. When impacting the press-fit cup, the surgical side was raised by 4.4° compared with the time of skin incision. This lift at the time of cup implantation correlates significantly with the body mass index and the patient's abdominal and pelvic circumference. Every surgeon performing THA must be aware of the pelvic lift during an operation. Especially in patients with a high body mass index, a large abdominal circumference, or a large pelvic circumference, there is an increased risk of malpositioning of the acetabular cup. When impacting the cup, we recommend releasing the traction of the retractor, so that the pelvis can tilt back into its natural position, and thus, the anticipated cup positioning can be implemented as exactly as possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Quantifying Blood Loss and Transfusion Risk After Primary vs Conversion Total Hip Arthroplasty.

    Science.gov (United States)

    Newman, Jared M; Webb, Matthew R; Klika, Alison K; Murray, Trevor G; Barsoum, Wael K; Higuera, Carlos A

    2017-06-01

    Primary total hip arthroplasty (THA) and conversion THA may result in substantial blood loss, sometimes necessitating transfusion. Despite the complexities of the latter, both are grouped in the same category for quality assessment and reimbursement. This study's purpose was to compare both blood loss and transfusion risk in primary and conversion THA and identify their associated predictors. A total of 1616 patients who underwent primary and conversion THA at a single hospital from 2009-2013 were reviewed (primary THA = 1575; conversion THA = 41). Demographics, comorbidities, and perioperative data were collected from electronic records. Blood loss was calculated using a validated method. Transfusion triggers were based on standardized criteria. Separate multivariable regression models for blood loss and transfusion were performed. Conversion THA patients were younger (P = .002), had lower age-adjusted Charlson scores (P = .006), longer surgeries (P quantified in the present study and showed consistent results between the 2 metrics. The differences between these procedures should be addressed during quality assurance because conversion THA is associated with higher resource utilization, which is important in the allocation of resources and tiered reimbursement strategies. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Total glucosides of paeony prevents juxta-articular bone loss in experimental arthritis

    OpenAIRE

    Wei, Chen Chao; You, Fan Tian; Mei, Li Yu; Jian, Sun; Qiang, Chen Yong

    2013-01-01

    Background Total glucosides of paeony (TGP) is a biologically active compound extracted from Paeony root. TGP has been used in rheumatoid arthritis therapy for many years. However, the mechanism by which TGP prevents bone loss has been less explored. Methods TGP was orally administered for 3?months to New Zealand rabbits with antigen-induced arthritis (AIA). Digital x-ray knee images and bone mineral density (BMD) measurements of the subchondral knee bone were performed before sacrifice. Chon...

  16. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties.

    Science.gov (United States)

    Martin, Audrey J; Seagers, Kirsten A; Van Citters, Douglas W

    2017-07-01

    Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Metastatic spread from squamous cell carcinoma of the hypopharynx to the totally implantable venous access port insertion site: Case report and review of literature.

    Science.gov (United States)

    Mangla, Ankit; Agarwal, Nikki; Mullane, Michael Russell

    2017-12-01

    The totally implantable venous access port plays a crucial role in delivering chemotherapy in the outpatient setting. Here, we report the first case of a patient with hypopharyngeal tumor who developed chest wall metastasis over the totally implantable venous access port inserted in the internal jugular vein. Our patient, a 58-year-old man with a hypopharyngeal tumor presented with a lump over the totally implantable venous access port site. The port was removed and the lump was biopsied. The CT studies showed that the tumor had spread along the catheter from the hypopharynx to the chest wall. The pathology from the biopsy showed squamous cell carcinoma (SCC). The patient had poor performance status and opted for hospice care. We present a novel case of metastasis over the totally implantable venous access port implanted in a patient with a hypopharyngeal tumor. We also reviewed relevant literature comparing the data from percutaneous endoscopic gastrostomy (PEG) tube site metastasis with our patient and other similar case reports. © 2017 Wiley Periodicals, Inc.

  18. Tranexamic acid for control of blood loss in bilateral total knee replacement in a single stage

    Directory of Open Access Journals (Sweden)

    Mandeep S Dhillon

    2011-01-01

    Full Text Available Background: Tranexamic acid (TEA reduces blood loss and red cell transfusions in patients undergoing unilateral total knee arthroplasty (TKA. However, there is not much literature regarding the use of TEA in patients undergoing bilateral TKA in a single stage and the protocols for administration of TEA in such patients are ill-defined. Materials and Methods: We carried out a case control study evaluating the effect of TEA on postoperative hemoglobin (Hb, total drain output, and number of blood units transfused in 52 patients undergoing bilateral TKA in a single stage, and compared it with 56 matched controls who did not receive TEA. Two doses of TEA were administered in doses of 10 mg / kg each (slow intravenous (IV infusion, with the first dose given just before tourniquet release of the first knee and the second dose three hours after the first one. Results: A statistically significant reduction in the total drain output and requirement of allogenic blood transfusion in cases who received TEA, as compared to the controls was observed. The postoperative Hb and Hb at the time of discharge were found to be lower in the control group, and this result was found to be statistically significant. Conclusion: TEA administered in patients undergoing single stage bilateral TKA helped reduce total blood loss and decreased allogenic blood transfusion requirements. This might be particularly relevant, where facilities such as autologous reinfusion might not be available.

  19. How Acute Total Sleep Loss Affects the Attending Brain: A Meta-Analysis of Neuroimaging Studies

    Science.gov (United States)

    Ma, Ning; Dinges, David F.; Basner, Mathias; Rao, Hengyi

    2015-01-01

    Study Objectives: Attention is a cognitive domain that can be severely affected by sleep deprivation. Previous neuroimaging studies have used different attention paradigms and reported both increased and reduced brain activation after sleep deprivation. However, due to large variability in sleep deprivation protocols, task paradigms, experimental designs, characteristics of subject populations, and imaging techniques, there is no consensus regarding the effects of sleep loss on the attending brain. The aim of this meta-analysis was to identify brain activations that are commonly altered by acute total sleep deprivation across different attention tasks. Design: Coordinate-based meta-analysis of neuroimaging studies of performance on attention tasks during experimental sleep deprivation. Methods: The current version of the activation likelihood estimation (ALE) approach was used for meta-analysis. The authors searched published articles and identified 11 sleep deprivation neuroimaging studies using different attention tasks with a total of 185 participants, equaling 81 foci for ALE analysis. Results: The meta-analysis revealed significantly reduced brain activation in multiple regions following sleep deprivation compared to rested wakefulness, including bilateral intraparietal sulcus, bilateral insula, right prefrontal cortex, medial frontal cortex, and right parahippocampal gyrus. Increased activation was found only in bilateral thalamus after sleep deprivation compared to rested wakefulness. Conclusion: Acute total sleep deprivation decreases brain activation in the fronto-parietal attention network (prefrontal cortex and intraparietal sulcus) and in the salience network (insula and medial frontal cortex). Increased thalamic activation after sleep deprivation may reflect a complex interaction between the de-arousing effects of sleep loss and the arousing effects of task performance on thalamic activity. Citation: Ma N, Dinges DF, Basner M, Rao H. How acute total

  20. Blood Loss and Transfusion After Topical Tranexamic Acid Administration in Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Wang, Hao; Shen, Bin; Zeng, Yi

    2015-11-01

    There has been much debate and controversy about the safety and efficacy of the topical use of tranexamic acid in primary total knee arthroplasty (TKA). The purpose of this study was to perform a meta-analysis to evaluate whether there is less blood loss and lower rates of transfusion after topical tranexamic acid administration in primary TKA. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized, controlled trials and prospective cohort studies evaluating the effectiveness of topical tranexamic acid during primary TKA were included. The focus of the analysis was on the outcomes of blood loss results, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 387 studies identified, 16 comprising 1421 patients (1481 knees) were eligible for data extraction and meta-analysis. This study indicated that when compared with the control group, topical application of tranexamic acid significantly reduced total drain output (mean difference, -227.20; 95% confidence interval, -347.11 to -107.30; Ptranexamic acid in primary TKA. Furthermore, the currently available evidence does not support an increased risk of deep venous thrombosis or pulmonary embolism due to tranexamic acid administration. Topical tranexamic acid was effective for reducing postoperative blood loss and transfusion requirements without increasing the prevalence of thromboembolic complications. Copyright 2015, SLACK Incorporated.

  1. Dynamical observation of lithium insertion/extraction reaction during charge-discharge processes in Li-ion batteries by in situ spatially resolved electron energy-loss spectroscopy.

    Science.gov (United States)

    Shimoyamada, Atsushi; Yamamoto, Kazuo; Yoshida, Ryuji; Kato, Takehisa; Iriyama, Yasutoshi; Hirayama, Tsukasa

    2015-12-01

    All-solid-state Li-ion batteries (LIBs) with solid electrolytes are expected to be the next generation devices to overcome serious issues facing conventional LIBs with liquid electrolytes. However, the large Li-ion transfer resistance at the electrode/solid-electrolyte interfaces causes low power density and prevents practical use. In-situ-formed negative electrodes prepared by decomposing the solid electrolyte Li(1+x+3z)Alx(Ti,Ge)(2-x)Si(3z)P(3-z)O12 (LASGTP) with an excess Li-ion insertion reaction are effective electrodes providing low Li-ion transfer resistance at the interfaces. Prior to our work, however, it had still been unclear how the negative electrodes were formed in the parent solid electrolytes. Here, we succeeded in dynamically visualizing the formation by in situ spatially resolved electron energy-loss spectroscopy in a transmission electron microscope mode (SR-TEM-EELS). The Li-ions were gradually inserted into the solid electrolyte region around 400 nm from the negative current-collector/solid-electrolyte interface in the charge process. Some of the ions were then extracted in the discharge process, and the rest were diffused such that the distribution was almost flat, resulting in the negative electrodes. The redox reaction of Ti(4+)/Ti(3+) in the solid electrolyte was also observed in situ during the Li insertion/extraction processes. The in situ SR-TEM-EELS revealed the mechanism of the electrochemical reaction in solid-state batteries. © The Author 2015. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Loss of P53 Function in Colon Cancer Cells Results in Increased Phosphocholine and Total Choline

    Directory of Open Access Journals (Sweden)

    Noriko Mori

    2004-10-01

    Full Text Available Mutations in the p53 gene are the most frequently observed genetic lesions in human cancers. Human cancers that contain a p53 mutation are more aggressive, more apt to metastasize, and more often fatal. p53 controls numerous downstream targets that can influence various outcomes such as apoptosis, growth arrest, and DNA repair. Based on previous observations using 1H magnetic resonance spectroscopy (MRS, we have identified choline phospholipid metabolite intensities typical of increased malignancy. Here we have used 1H MRS to characterize the choline phospholipid metabolite levels of p53+/+ and p53−/– cells, and demonstrated that loss of p53 function results in increased phosphocholine and total choline. These data suggest that the increased malignancy of cancer cells resulting from loss of p53 may be mediated, in part, through the choline phospholipid pathway.

  3. Hyperbolic-cosine waveguide tapers and oversize rectangular waveguide for reduced broadband insertion loss in W-band electron paramagnetic resonance spectroscopy. II. Broadband characterization

    Energy Technology Data Exchange (ETDEWEB)

    Sidabras, Jason W.; Anderson, James R.; Mainali, Laxman; Hyde, James S. [Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Strangeway, Robert A. [Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Department of Electrical Engineering and Computer Science, Milwaukee School of Engineering, Milwaukee, Wisconsin 53201 (United States); Mett, Richard R. [Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin 53226 (United States); Department of Chemistry and Physics, Milwaukee School of Engineering, Milwaukee, Wisconsin 53201 (United States)

    2016-03-15

    Experimental results have been reported on an oversize rectangular waveguide assembly operating nominally at 94 GHz. It was formed using commercially available WR28 waveguide as well as a pair of specially designed tapers with a hyperbolic-cosine shape from WR28 to WR10 waveguide [R. R. Mett et al., Rev. Sci. Instrum. 82, 074704 (2011)]. The oversize section reduces broadband insertion loss for an Electron Paramagnetic Resonance (EPR) probe placed in a 3.36 T magnet. Hyperbolic-cosine tapers minimize reflection of the main mode and the excitation of unwanted propagating waveguide modes. Oversize waveguide is distinguished from corrugated waveguide, overmoded waveguide, or quasi-optic techniques by minimal coupling to higher-order modes. Only the TE{sub 10} mode of the parent WR10 waveguide is propagated. In the present work, a new oversize assembly with a gradual 90° twist was implemented. Microwave power measurements show that the twisted oversize waveguide assembly reduces the power loss in the observe and pump arms of a W-band bridge by an average of 2.35 dB and 2.41 dB, respectively, over a measured 1.25 GHz bandwidth relative to a straight length of WR10 waveguide. Network analyzer measurements confirm a decrease in insertion loss of 2.37 dB over a 4 GHz bandwidth and show minimal amplitude distortion of approximately 0.15 dB. Continuous wave EPR experiments confirm these results. The measured phase variations of the twisted oversize waveguide assembly, relative to an ideal distortionless transmission line, are reduced by a factor of two compared to a straight length of WR10 waveguide. Oversize waveguide with proper transitions is demonstrated as an effective way to increase incident power and the return signal for broadband EPR experiments. Detailed performance characteristics, including continuous wave experiment using 1 μM 2,2,6,6-tetramethylpiperidine-1-oxyl in aqueous solution, provided here serve as a benchmark for other broadband low-loss probes in

  4. Hyperbolic-cosine waveguide tapers and oversize rectangular waveguide for reduced broadband insertion loss in W-band electron paramagnetic resonance spectroscopy. II. Broadband characterization

    International Nuclear Information System (INIS)

    Sidabras, Jason W.; Anderson, James R.; Mainali, Laxman; Hyde, James S.; Strangeway, Robert A.; Mett, Richard R.

    2016-01-01

    Experimental results have been reported on an oversize rectangular waveguide assembly operating nominally at 94 GHz. It was formed using commercially available WR28 waveguide as well as a pair of specially designed tapers with a hyperbolic-cosine shape from WR28 to WR10 waveguide [R. R. Mett et al., Rev. Sci. Instrum. 82, 074704 (2011)]. The oversize section reduces broadband insertion loss for an Electron Paramagnetic Resonance (EPR) probe placed in a 3.36 T magnet. Hyperbolic-cosine tapers minimize reflection of the main mode and the excitation of unwanted propagating waveguide modes. Oversize waveguide is distinguished from corrugated waveguide, overmoded waveguide, or quasi-optic techniques by minimal coupling to higher-order modes. Only the TE 10 mode of the parent WR10 waveguide is propagated. In the present work, a new oversize assembly with a gradual 90° twist was implemented. Microwave power measurements show that the twisted oversize waveguide assembly reduces the power loss in the observe and pump arms of a W-band bridge by an average of 2.35 dB and 2.41 dB, respectively, over a measured 1.25 GHz bandwidth relative to a straight length of WR10 waveguide. Network analyzer measurements confirm a decrease in insertion loss of 2.37 dB over a 4 GHz bandwidth and show minimal amplitude distortion of approximately 0.15 dB. Continuous wave EPR experiments confirm these results. The measured phase variations of the twisted oversize waveguide assembly, relative to an ideal distortionless transmission line, are reduced by a factor of two compared to a straight length of WR10 waveguide. Oversize waveguide with proper transitions is demonstrated as an effective way to increase incident power and the return signal for broadband EPR experiments. Detailed performance characteristics, including continuous wave experiment using 1 μM 2,2,6,6-tetramethylpiperidine-1-oxyl in aqueous solution, provided here serve as a benchmark for other broadband low-loss probes in

  5. Effects of total flavonoids from Drynariae Rhizoma prevent bone loss in vivo and in vitro

    Directory of Open Access Journals (Sweden)

    Shuang-hong Song

    2016-12-01

    Full Text Available Estrogen deficiency is one of the major causes of osteoporosis in postmenopausal women. Drynariae Rhizoma is a widely used traditional Chinese medicine for the treatment of bone diseases. In this study, we investigated the therapeutic effects of the total Drynariae Rhizoma flavonoids (DRTF on estrogen deficiency-induced bone loss using an ovariectomized rat model and osteoblast-like MC3T3-E1 cells. Our results indicated that DRTF produced osteo-protective effects on the ovariectomized rats in terms of bone loss reduction, including decreased levels of bone turnover markers, enhanced biomechanical femur strength and trabecular bone microarchitecture deterioration prevention. In vitro experiments revealed that the actions of DRTF on regulating osteoblastic activities were mediated by the estrogen receptor (ER dependent pathway. Our data also demonstrated that DRTF inhibited osteoclastogenesis via up-regulating osteoprotegrin (OPG, as well as down-regulating receptor activator of NF–κB ligand (RANKL expression. In conclusion, this study indicated that DRTF treatment effectively suppressed bone mass loss in an ovariectomized rat model, and in vitro evidence suggested that the effects were exerted through actions on both osteoblasts and osteoclasts. Keywords: Osteoporosis, Osteoblast, Osteoclast, Ovariectomy, Drynariae Rhizoma

  6. ATWS analysis for total loss of feedwater sequence in UCN 3 and 4

    International Nuclear Information System (INIS)

    Park, S. H.; Song, Y. M.; Kim, D. H.; Kim, S. D.; Park, S. Y.

    1999-01-01

    ATWS is a trip-failed severe accident initiated from the transients like a turbine trip, a control bank withdrawal, and a loss of feedwater which are expected to occur comparatively often (one or two occurrences / year). In this study, an ATWS sequence in Ulchin 3 and 4 is analyzed and the effects of the important systems are studied for accident management purpose using a MIDAS/PK computer code. The MIDAS/PK code has been developed via coupling a point kinetics module with the MELCOR code. The code calculates a primary peak pressure of about 24MPa at 240 seconds for the ATWS initiated by a TLOF (Total Loss of Feedwater) transient. Along with the basic ATWS analysis, several sensitivity runs are performed. From these, the turbines and the safety depressurization system (SDS) are judged to be important. The turbine trip resulting in a loss of offsite power and a RCP trip, degrades primary heat transfer to the secondary sides, and in turn, increases primary coolant temperature which reduces the reactor power due to the negative moderator temperature coefficient. Manual operation of SDS has an effect to lower the primary peak pressure considerably via supplementary depressurization in addition to the PORVs

  7. Stop of loss of cognitive performance during rehabilitation after total hip arthroplasty-prospective controlled study.

    Science.gov (United States)

    Brem, Matthias H; Lehrl, Siegfried; Rein, Anna K; Massute, Sylvia; Schulz-Drost, Stefan; Gelse, Kolja; Schlechtweg, Phillip M; Hennig, Friedrich F; Olk, Alexander; Jacob, Harald J; Gusinde, Johannes

    2010-01-01

    Prolonged hospitalization is known to be associated with a loss of cognitive performance. Does playing video games (VGs) developed to improve cognitive properties delay this loss or even lead to an increase in cognitive performance? We performed a 10-day longitudinal study of patients who received total hip arthroplasty. We compared 16 patients (6 male) aged 66 ± 9 years (mean ± standard deviation) who played Dr. Kawashima's Brain Training: How Old Is Your Brain? (Nintendo; Redmond, Washington) on a Nintendo DS handheld console with 16 control patients (6 male) aged 69 ± 14 years. We measured cognitive performance 1 day preoperation, as well as on days 2 and 9 postoperation. With the daily exercise of a specific VG by the play group, the patients' fluid intelligence (median intelligence quotient 99-106), working memory capacity, and rate of information processing significantly improved over the course of 7 postoperative days. The cognitive performance of the control group did not increase. However, the memory spans of both groups did not systematically change. Exercise with VGs can prevent the loss of cognitive performance during prolonged hospitalization.

  8. Use of tranexamic acid in primary total knee replacement: effects on perioperative blood loss.

    Science.gov (United States)

    Volquind, Daniel; Zardo, Remi Antônio; Winkler, Bruno Costamilan; Londero, Bruno Bertagnolli; Zanelatto, Natália; Leichtweis, Gisele Perondi

    2016-01-01

    The use of tranexamic acid in primary total knee replacement surgeries has been the subject of constant study. The strategies to reduce bleeding are aimed at reducing the need for blood transfusion due to the risks involved. In this study we evaluated the use of tranexamic acid in reducing bleeding, need for blood transfusion, and prevalence of postoperative deep vein thrombosis in primary total knee replacement. 62 patients undergoing primary total knee replacement were enrolled in the study, from June 2012 to May 2013, and randomized to receive a single dose of 2.5g of intravenous tranexamic acid (Group TA) or saline (Group GP), 5min before opening the pneumatic tourniquet, respectively. Hemoglobin, hematocrit, and blood loss were recorded 24h after surgery. Deep vein thrombosis was investigated during patient's hospitalization and 15 and 30 days after surgery in review visits. There was no demographic difference between groups. Group TA had 13.89% decreased hematocrit (p=0.925) compared to placebo. Group TA had a decrease of 12.28% (p=0.898) in hemoglobin compared to Group GP. Group TA had a mean decrease of 187.35mL in blood loss (25.32%) compared to group GP (p=0.027). The number of blood transfusions was higher in Group GP (p=0.078). Thromboembolic events were not seen in this study. Tranexamic acid reduced postoperative bleeding without promoting thromboembolic events. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  9. How acute total sleep loss affects the attending brain: a meta-analysis of neuroimaging studies.

    Science.gov (United States)

    Ma, Ning; Dinges, David F; Basner, Mathias; Rao, Hengyi

    2015-02-01

    Attention is a cognitive domain that can be severely affected by sleep deprivation. Previous neuroimaging studies have used different attention paradigms and reported both increased and reduced brain activation after sleep deprivation. However, due to large variability in sleep deprivation protocols, task paradigms, experimental designs, characteristics of subject populations, and imaging techniques, there is no consensus regarding the effects of sleep loss on the attending brain. The aim of this meta-analysis was to identify brain activations that are commonly altered by acute total sleep deprivation across different attention tasks. Coordinate-based meta-analysis of neuroimaging studies of performance on attention tasks during experimental sleep deprivation. The current version of the activation likelihood estimation (ALE) approach was used for meta-analysis. The authors searched published articles and identified 11 sleep deprivation neuroimaging studies using different attention tasks with a total of 185 participants, equaling 81 foci for ALE analysis. The meta-analysis revealed significantly reduced brain activation in multiple regions following sleep deprivation compared to rested wakefulness, including bilateral intraparietal sulcus, bilateral insula, right prefrontal cortex, medial frontal cortex, and right parahippocampal gyrus. Increased activation was found only in bilateral thalamus after sleep deprivation compared to rested wakefulness. Acute total sleep deprivation decreases brain activation in the fronto-parietal attention network (prefrontal cortex and intraparietal sulcus) and in the salience network (insula and medial frontal cortex). Increased thalamic activation after sleep deprivation may reflect a complex interaction between the de-arousing effects of sleep loss and the arousing effects of task performance on thalamic activity. © 2015 Associated Professional Sleep Societies, LLC.

  10. Simulation of total loss of feed water in ATLAS test facility using SPACE code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minhee; Kim, Seyun [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of). Central Research Inst.

    2017-08-15

    A total loss of feedwater (TLOFW) with additional failures in ATLAS test facility was analyzed using SPACE code, which is an advanced thermal-hydraulic system analysis code developed by the Korea nuclear industry. Partial failure of the safety injection pumps (SIPs) and the pilot-operated safety relief valves (POSRVs) of pressurizer were selected as additional failures. In order to assess the capability of SPACE code, partial failure was modeled, and compared with results of OECD-ATLAS A3.1 results. Reasonably good agreement with major thermal-hydraulic parameters was obtained by analyzing the transient behavior. From the results, this indicated that SPACE code has capabilities to design extension conditions, and feed and bleed operation using POSRVs and SIPs were effective for RCS cooling capability during TLOFW.

  11. Tourniquets do not increase the total blood loss or re-amputation risk in transtibial amputations

    DEFF Research Database (Denmark)

    Wied, Christian; Tengberg, Peter T; Holm, Gitte

    2017-01-01

    AIM: To investigate the total blood loss (TBL) and the safety with respect to the re-amputation rate after transtibial amputation (TTA) conducted with and without a tourniquet. METHODS: The study was a single-centre retrospective cohort study of patients with a primary TTA admitted between January...... 2013 and April 2015. All patients with a primary TTA were assessed for inclusion if the amputation was performed because of arteriosclerosis or diabetic complications. All patients underwent a standardized TTA procedure that was performed approximately 10 cm below the knee joint and performed...... portion, which equals 55 g/L of haemoglobin. The TBL during the first four postoperative days was calculated based on the haemoglobin level and the estimated blood volume. The re-amputation rate was evaluated within 30 d. RESULTS: Seventy-four out of 86 consecutive patients who underwent TTA within...

  12. Evaluation of total loss of feedwater accident/recovery phase and investigation of the associated EOP

    International Nuclear Information System (INIS)

    Bang, Young Seok; Seul, Kwang Won; Kim, Hho Jung

    1993-01-01

    To evaluate the sequence of event and the thermohydraulic behavior during total loss of feedwater accident and recovery procedure, a RELAP5/MOD3 calculation is performed and compared with the LOFT L9-1/L3-3 experiment. Also, the predictability of the code for the major thermohydraulic phenomena following the accident is assessed. As a result, it is found that a pressure control using the spray until the time the water level reaches the top of the pressurizer, an overpressure protection by pressurizer PORV, a recovery of the secondary heat removal capability by refilling steam generator, and an effective cooldown by the continued natural circulation can be perfomed without core uncovery. It is also found that the plantspecific evaluation is necessary to confirm the effectiveness of the current symptom-oriented emergency operating procedure, especially in an overpressure protection performance and steam generator recovery performance. (Author)

  13. Comparative study of topical vs. intravenous tranexamic acid regarding blood loss in total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Ari Zekcer

    Full Text Available ABSTRACT Objective: To compare topical vs. intravenous tranexamic acid (TA in total knee arthroplasty regarding blood loss and transfusion., Methods: Ninety patients were randomized to receive TA intravenously (20 mg/kg in 100 mL of saline; group IV, topically (1.5 g in 50 mL of saline, sprayed over the operated site, before release of the tourniquet; topical group, or intravenous saline (100 mL with anesthesia; control group. The volume of drained blood in 48, h, the amount of transfused blood, and the serum levels of hemoglobin and hematocrit before and after surgery were evaluated., Results: The groups were similar for gender, age, weight, laterality, and preoperative hemoglobin and hematocrit levels (p> 0.2. The hemoglobin level dropped in all groups when comparing the preoperative and the 48-h evaluations: the control group decreased 3.8 mg/dL on average, while the IV, group had a decrease of 3.0, and the topical group, of 3.2 (p= 0.019. The difference between the control and IV, groups was confirmed by Bonferroni test (p= 0.020. The difference between the control group and the topical group was not significant (p= 0.130, although there was less reduction in hemoglobin in the topical group; the comparison between the IV, group and the topical group was also not significant (p= 1.000. Conclusion: Using topic and IV, tranexamic acid decreased blood loss and the need for transfusion in total knee arthroplasty. Topical application showed results similar to IV use regarding the need for blood transfusion, but without the possible side effects of IV, administration.

  14. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  15. Continuing versus discontinuing antiplatelet drugs, vasodilators, and/or cerebral ameliorators on perioperative total blood loss in total knee arthroplasty without pneumatic tourniquet

    Directory of Open Access Journals (Sweden)

    Sachiyuki Tsukada, MD

    2018-03-01

    Full Text Available Background: Although studies have supported the utility of perioperative continuation of antiplatelet drugs, vasodilators, and cerebral ameliorators in most procedures, no study compared total volume of blood loss after total knee arthroplasty (TKA in patients continuing and discontinuing these drugs. Methods: We retrospectively reviewed 266 consecutive patients undergoing TKA, and included 67 patients (25.2% taking antiplatelet drugs, vasodilators, or cerebral ameliorators in this study. All TKAs were performed without a pneumatic tourniquet. The primary outcome was perioperative total blood loss calculated from blood volume and change in hemoglobin. As subgroup analysis, we compared perioperative total blood loss in patients taking antiplatelet drugs. Results: There was no significant difference between the continuing group (n = 38 and discontinuing group (n = 29 in terms of the perioperative total blood loss (1025 ± 364 vs 1151 ± 327 mL, respectively; mean difference 126 mL; 95% confidence interval −45 to 298 mL; P = .15. No major bleeding or thrombotic events occurred in either group until postoperative 3-month follow-up. In patients taking antiplatelet drugs (n = 51, no significant difference was observed in the total blood loss between the continuing group (n = 30 and discontinuing group (n = 21 (1056 ± 287 vs 1151 ± 305 mL, respectively; mean difference 95 mL; 95% confidence interval −75 to 264 mL; P = .27. Conclusions: No significant differences in terms of perioperative total blood loss were observed between patients continuing and discontinuing study drugs. Continuing these drugs may be preferable in the perioperative period of TKA. Keywords: Knee, Primary arthroplasty, Bleeding events, Thrombotic events, Noncardiac surgery

  16. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    Science.gov (United States)

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  17. Measurement of impulse peak insertion loss from two acoustic test fixtures and four hearing protector conditions with an acoustic shock tube

    Science.gov (United States)

    Murphy, William J.; Fackler, Cameron J.; Berger, Elliott H.; Shaw, Peter B.; Stergar, Mike

    2015-01-01

    Impulse peak insertion loss (IPIL) was studied with two acoustic test fixtures and four hearing protector conditions at the E-A-RCAL Laboratory. IPIL is the difference between the maximum estimated pressure for the open-ear condition and the maximum pressure measured when a hearing protector is placed on an acoustic test fixture (ATF). Two models of an ATF manufactured by the French-German Research Institute of Saint-Louis (ISL) were evaluated with high-level acoustic impulses created by an acoustic shock tube at levels of 134 decibels (dB), 150 dB, and 168 dB. The fixtures were identical except that the E-A-RCAL ISL fixture had ear canals that were 3 mm longer than the National Institute for Occupational Safety and Health (NIOSH) ISL fixture. Four hearing protection conditions were tested: Combat Arms earplug with the valve open, ETYPlugs® earplug, TacticalPro headset, and a dual-protector ETYPlugs earplug with TacticalPro earmuff. The IPILs measured for the E-A-RCAL fixture were 1.4 dB greater than the National Institute for Occupational Safety and Health (NIOSH) ISL ATF. For the E-A-RCAL ISL ATF, the left ear IPIL was 2.0 dB greater than the right ear IPIL. For the NIOSH ATF, the right ear IPIL was 0.3 dB greater than the left ear IPIL. PMID:26356380

  18. Beyond deficit or compensation: new insights on postural control after long-term total visual loss.

    Science.gov (United States)

    Russo, Maitê M; Lemos, Thiago; Imbiriba, Luís A; Ribeiro, Nathalia L; Vargas, Claudia D

    2017-02-01

    Loss of vision is well known to affect postural control in blind subjects. This effect has classically been framed in terms of deficit or compensation depending on whether body sway increases or decreases in comparison with that of sighted subjects with the eyes open. However, studies have shown that postural responses can be modulated by the context and that changes in postural sway may not necessarily mean a worsened or improved postural control. The goal of our study was to test whether balance is affected by the context in blind subjects. Additional to the quantification of center of pressure (COP) displacement, measurements of body motion (COG) and the correspondent net neuromuscular response (COP-COG) were evaluated in anterior-posterior and medial-lateral directions. Thirty-eight completely blind and thirty-two sighted subjects participated of this study. The volunteers were asked to stand barefoot on a force platform for 60 s in two different conditions: feet apart and feet together. Sighted participants performed the tests with both the eyes open and eyes closed. Results showed that the COP-COG displacements in the blind group were greater than those of the sighted group with eyes open in almost all conditions tested, but not in eyes closed condition. However, the COP and COG results confirmed that the postural responses were context dependent. Together these results suggest that total visual loss does not just lead to a balance deficit or compensation, but to a specific postural signature that might imply in enhancing COP, COG and/or COP-COG in specific postural conditions.

  19. Total glucosides of paeony prevents juxta-articular bone loss in experimental arthritis.

    Science.gov (United States)

    Wei, Chen Chao; You, Fan Tian; Mei, Li Yu; Jian, Sun; Qiang, Chen Yong

    2013-07-21

    Total glucosides of paeony (TGP) is a biologically active compound extracted from Paeony root. TGP has been used in rheumatoid arthritis therapy for many years. However, the mechanism by which TGP prevents bone loss has been less explored. TGP was orally administered for 3 months to New Zealand rabbits with antigen-induced arthritis (AIA). Digital x-ray knee images and bone mineral density (BMD) measurements of the subchondral knee bone were performed before sacrifice. Chondrocytes were observed using transmission electron microscopy (TEM). Histological analysis and mRNA expression of receptor activator of nuclear factor-B ligand (RANKL) and osteoprotegerin (OPG) were evaluated in joint tissues. The BMD value in TGP rabbits was significantly higher compared with that seen in the AIA model rabbits. In addition, the subchondral bone plate was almost completely preserved by TGP treatment, while there was a decrease in bone plate integrity in AIA rabbits. There was less damage to the chondrocytes of the TGP treated group. Immunohistochemical examination of the TGP group showed that a higher percentage of TGP treated chondrocytes expressed OPG as compared to the chondrocytes isolated from AIA treated animals. In contrast, RANKL expression was significantly decreased in the TGP treated group compared to the AIA group. In support of the immunohistochemistry data, the expression of RANKL mRNA was decreased and OPG mRNA expression was enhanced in the TGP group when compared to that of the AIA model group. These results reveal that TGP suppresses juxta-articular osteoporosis and prevents subchondral bone loss. The decreased RANKL and increased OPG expression seen in TGP treated animals could explain how administration of TGP maintains higher BMD.

  20. Total serum bilirubin levels and sensorineural hearing loss in the US adolescents: NHANES 2007-2010.

    Science.gov (United States)

    Zhou, Guoli; Fu, Wenjiang

    2018-02-01

    We aimed to investigate whether current levels of total serum bilirubin are associated with different subtypes of sensorineural hearing loss (SNHL) in adolescents. A set of cross-sectional data from the National Health and Nutrition Examination Survey (NHANES) (2007-2010) was used. A subset of 1404 adolescents was sampled for measurements of total serum bilirubin, tympanometry, and average pure tone threshold at low-frequencies (LPTA: 500, 1000, 2000 Hz) or high-frequencies (HPTA: 3000, 4000, 6000, and 8000 Hz). SNHL was defined as the hearing loss that had type A tympanograms with a peak admittance of 0.3 ml or greater. Associations between serum bilirubin (square-root transformed) and different subtypes of SNHL were evaluated using binary or multinomial logistic regression models with 4-year sampling weights. The bootstrap method was used for estimation of variance and 10-fold cross-validation for assessment of overfitting issue. Total serum bilirubin levels were found to be associated with any high-frequency (HPTA>15 dB in at least one ear, adjusted odds-ratio (OR a )(bootstrap 95% confidence interval) = 3.29(1.31-8.19), p = 0.011), but not with any low-frequency (LPTA>15 dB in at least one ear), SNHL in the US adolescents. Furthermore, high-frequency SNHL with HPTA>15 dB in both ears (bilateral) or HPTA≥25 dB in at least one ear, compared to that with HPTA>15 dB in one ear only (unilateral) or HPTA = 15-25 dB in at least one ear, had a stronger association with total serum bilirubin levels (OR a  = 5.37(1.27-22.65), p = 0.022 for bilateral; OR a  = 2.64(0.84-8.25), p = 0.094 for unilateral; OR a  = 5.00(0.95-26.58), p = 0.058 for HPTA≥25 dB in at least one ear; as well as OR a  = 3.06(1.15-8.25), p = 0.025 for HPTA = 15-25 dB in at least one ear). No severe overfitting problems were found. Our findings suggest that current levels of total serum bilirubin may be informative in predicting and/or targeting high-frequency SNHL

  1. Protocol of an expertise based randomized trial comparing surgical Venae Sectio versus radiological Puncture of Vena Subclavia for insertion of Totally Implantable Access Port in oncological patients

    Directory of Open Access Journals (Sweden)

    Radeleff Boris

    2008-10-01

    Full Text Available Abstract Background Totally Implantable Access Ports (TIAP are being extensively used world-wide and can be expected to gain further importance with the introduction of new neoadjuvant and adjuvant treatments in oncology. Two different techniques for the implantation can be selected: A direct puncture of a central vein and the utilization of a Seldinger device or the surgical Venae sectio. It is still unclear which technique has the optimal benefit/risk ratio for the patient. Design A single-center, expertise based randomized, controlled superiority trial to compare two different TIAP implantation techniques. 100 patients will be included and randomized pre-operatively. All patients aged 18 years or older scheduled for primary elective implantation of a TIAP under local anesthesia who signed the informed consent will be included. The primary endpoint is the primary success rate of the randomized technique. Control Intervention: Venae Sectio will be employed to insert a TIAP by a surgeon; Experimental intervention: Punction of V. Subclavia will be used to place a TIAP by a radiologist. Duration of study: Approximately 10 months, follow up time: 90 days. Organisation/Responsibility The PORTAS 2 – Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The Center of Clinical Trials at the Department of Surgery, University Hospital Heidelberg is responsible for design and conduct of the trial including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI, University of Heidelberg. Trial Registration The trial is registered at ClinicalTrials.gov (NCT00600444.

  2. STEAM GENERATOR TUBE INTEGRITY ANALYSIS OF A TOTAL LOSS OF ALL HEAT SINKS ACCIDENT FOR WOLSONG NPP UNIT 1

    Directory of Open Access Journals (Sweden)

    HEOK-SOON LIM

    2014-02-01

    Full Text Available A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS and the steam generator (SG secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  3. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo [Korea Htydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of); Kim, Seoungrae [Nuclear Engineering Service and Solution, Daejeon (Korea, Republic of)

    2014-02-15

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident.

  4. Steam Generator Tube Integrity Analysis of A Total Loss of all Heat Sinks Accident for Wolsong NPP Unit 1

    International Nuclear Information System (INIS)

    Lim, Heoksoon; Song, Taeyoung; Chi, Moongoo; Kim, Seoungrae

    2014-01-01

    A total loss of all heat sinks is considered a severe accident with a low probability of occurrence. Following a total loss of all heat sinks, the degasser/condenser relief valves (DCRV) become the sole means available for the depressurization of the primary heat transport system. If a nuclear power plant has a total loss of heat sinks accident, high-temperature steam and differential pressure between the primary heat transport system (PHTS) and the steam generator (SG) secondary side can cause a SG tube creep rupture. To protect the PHTS during a total loss of all heat sinks accident, a sufficient depressurization capability of the degasser/condenser relief valve and the SG tube integrity is very important. Therefore, an accurate estimation of the discharge through these valves is necessary to assess the impact of the PHTS overprotection and the SG tube integrity of the primary circuit. This paper describes the analysis of DCRV discharge capacity and the SG tube integrity under a total loss of all heat sink using the CATHENA code. It was found that the DCRV's discharge capacity is enough to protect the overpressure in the PHTS, and the SG tube integrity is maintained in a total loss of all heat accident

  5. Total loss of CNA1 steam generators feed water simulated with RELAP5/MOD3

    International Nuclear Information System (INIS)

    Marino, Edgardo J.L.

    2000-01-01

    The results of the calculations are presented carried out by utilizing the code RELAP5/MOD3, upon the basis of the postulated initial event of total loss of feed water to the two steam generators in the nuclear power plant Atucha 1, CNA1. The evolution of the installation systems during the transient was analyzed in different conditions of availability: condenser, relief valve and safety valves in the secondary system, safety valves in the primary system and system of long-term subsequent cooling. Located in the primary and secondary systems of the installation they turn out to be prominent in this event. Upon this basis the sequences of possible evolution were calculated and those that would conduct the system toward the setting called 'damage to the core' were determined. Also those in which would arrive to a state of 'safe shutdown' were determined. These results were utilized in the verification of the tree of events utilized in the Final Report of the Probabilistic Safety Analysis for the sequence of event T9, made from calculations carried out with the code DINETZ. From this compare some differences were determined and are presented in the modified version of tree of events. (author)

  6. Analysis of Total Loss of Feedwater for APR1400 using SPACE

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Min; Park, Seok Jeong; Park, Chan Eok; Choi, Jong Ho; Lee, Gyu Cheon [KEPCO Engineering and Construction, Deajeon (Korea, Republic of)

    2016-10-15

    The Total Loss of FeedWater (TLOFW) event is an accident that main feedwater and auxiliary feedwater of secondary side are not supplied to steam generators. APR1400 uses the Safety Depressurization and Vent System (SDVS) for the F and B operation and SDVS is designed to perform the rapid depressurization function of Reactor Coolant System (RCS) through the remote manual operation when TLOFW is occurred. If RCS pressure falls below a Safety Injection Pump (SIP) working pressure, it can be possible to start the F and B operation which injects SIP flow to RCS and releases the RCS vapor and two-phase flow through Pilot Operated Safety Relief Valves (POSRVs) by opening the POSRVs, and then it can be possible to remove the decay heat. The design requirement of SDVS is that the core water level should be maintained at higher than 2 feet from the top of active core during the F and B operation. The TLOFW analysis was carried out to evaluate the capability of decay heat removal for APR1400 using newly developed SPACE code. The analysis results show that the F and B operation with 2 POSRVs and 2 SIPs and the F and B operation with 4 POSRVs and 4 SIPs meet the SDVS design requirement for the fuel cladding temperature. The comparison with RELAP5 shows good agreement and it validates the applicability of SPACE code for this type of accident analysis.

  7. Thermal-hydraulic analysis of total loss of steam generator feed water in WWER-440

    International Nuclear Information System (INIS)

    Sabotinov, L.; Cadet-Mercier, S.

    2001-01-01

    The analysis is carried out for a WWER-440/V270 with upgraded primary safety valves (replacement of the existing PRZ safety valves with Pilot Operated Relief Valves (PORV) of the type SEBIM (France)) The current analysis is focused on the scenario 'Total Loss of SGs Feed Water' with application of the operator action of primary system 'Feed and Bleed' in order to check the effectiveness of the installed pressurizer SEBIM valves and to verify that the operator can cool down the reactor system and cope with this accident. The calculations have been performed at the Institute of Protection and Nuclear Safety (IPSN) in Fontenay-aux-Roses with the computer code CATHARE 2 Version 1.3L1. CATHARE is a French best estimate thermal-hydraulic program for accident analysis in the light water nuclear reactors, developed with the participation of the IPSN (Institut de Protection et Surete Nucleaire), CEA (Commissariat a l'Energie Atomique), Framatome and EdF (Electricite de France). (author)

  8. A mathematical model of weight loss under total starvation: evidence against the thrifty-gene hypothesis

    Directory of Open Access Journals (Sweden)

    John R. Speakman

    2013-01-01

    The thrifty-gene hypothesis (TGH posits that the modern genetic predisposition to obesity stems from a historical past where famine selected for genes that promote efficient fat deposition. It has been previously argued that such a scenario is unfeasible because under such strong selection any gene favouring fat deposition would rapidly move to fixation. Hence, we should all be predisposed to obesity: which we are not. The genetic architecture of obesity that has been revealed by genome-wide association studies (GWAS, however, calls into question such an argument. Obesity is caused by mutations in many hundreds (maybe thousands of genes, each with a very minor, independent and additive impact. Selection on such genes would probably be very weak because the individual advantages they would confer would be very small. Hence, the genetic architecture of the epidemic may indeed be compatible with, and hence support, the TGH. To evaluate whether this is correct, it is necessary to know the likely effects of the identified GWAS alleles on survival during starvation. This would allow definition of their advantage in famine conditions, and hence the likely selection pressure for such alleles to have spread over the time course of human evolution. We constructed a mathematical model of weight loss under total starvation using the established principles of energy balance. Using the model, we found that fatter individuals would indeed survive longer and, at a given body weight, females would survive longer than males, when totally starved. An allele causing deposition of an extra 80 g of fat would result in an extension of life under total starvation by about 1.1–1.6% in an individual with 10 kg of fat and by 0.25–0.27% in an individual carrying 32 kg of fat. A mutation causing a per allele effect of 0.25% would become completely fixed in a population with an effective size of 5 million individuals in 6000 selection events. Because there have probably been about 24

  9. Comparision of blood loss between computer assisted and conventional total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Paras Kumar Mohanlal

    2013-01-01

    Conclusion: These results suggest that there is no significant difference in blood loss in CAS TKA and conventional TKA. This study also highlights the heterogeneity of methods used in studies related to CAS TKA. We believe that there is a need for a large multicenter prospective randomized controlled trial to be performed before a consensus can be reached on the influence of CAS techniques on blood loss during primary TKA.

  10. Random Insertion of mCherry Into VP3 Domain of Adeno-associated Virus Yields Fluorescent Capsids With no Loss of Infectivity

    Directory of Open Access Journals (Sweden)

    Justin Judd

    2012-01-01

    Full Text Available Adeno-associated virus (AAV-derived vectors are promising gene delivery systems, and a number of design strategies have been pursued to improve their performance. For example, genetic insertion of proteins into the capsid may be used to achieve vector retargeting, reduced immunogenicity, or to track vector transport. Unfortunately, rational approaches to genetic insertion have experienced limited success due to the unpredictable context-dependent nature of protein folding and the complexity of the capsid's macroassembly. We report the construction and use of a frame-enriched DNase-based random insertion library based on AAV2 cap, called pAAV2_RaPID (Random Peptide Insertion by DNase. The fluorescent mCherry protein was inserted randomly throughout the AAV2 capsid and the library was selected for fluorescent and infectious variants. A capsid site was identified in VP3 that can tolerate the large protein insertion. In contrast to previous efforts to incorporate fluorescent proteins into the AAV2 capsid, the isolated mCherry mutant maintains native infectivity while displaying robust fluorescence. Collectively, these results demonstrate that the pAAV2_RaPID platform library can be used to create fully infectious AAV vectors carrying large functional protein domains on the capsid.

  11. [Total dream loss secondary to left temporo-occipital brain injury].

    Science.gov (United States)

    Poza, J J; Martí Massó, J F

    2006-04-01

    Recently the case of a woman who reported cessation of dreaming after a bilateral PCA stroke but without REM sleep loss has been reported, suggesting that deep bilateral occipital lobe damage including the right inferior lingual gyrus may represent the "minimal lesion extension" necessary for dream loss. We report the case of a 24-year-old man who ceased dreaming after a unilateral left temporo- occipital hematoma. The polysomnographic characteristics in rapid eyes movements (REM) sleep were otherwise normal. Our patient demonstrates that a unilateral left temporo-occipital injury could be sufficient for losing dreams.

  12. Is intraarticular administration of tranexamic acid better than its intravenous administration in reducing blood loss after total knee arthroplasty?

    Directory of Open Access Journals (Sweden)

    Ameet Pispati

    2013-01-01

    Full Text Available Context: It has been well-established now that intravenous (IV tranexamic acid (TXA is a potent agent to control postoperative blood loss following total knee arthroplasty (TKA. Recently, intraarticular administration of this agent has also shown good efficacy for the same. Aims: Comparison of postoperative blood loss between IV and topical administration of TXA in TKAs. Materials and Design: Eighty-six TKAs on knees were included in this study. Randomization was done so that 40 TKA received 1 g of IV TXA, while 46 had intraarticular administration of 1 g TXA. Subjets and Methods: We compared the postoperative blood loss by calculating the difference in pre- and postop hemoglobin and need for blood transfusion. Functional assessment was done on basis of Western Ontario McMaster Osteo-Arthritis Index (WOMAC scores and complications like postoperative infection, oozing from the wound site and thromboembolic manifestations. Results: Blood loss was significantly less in the intraarticular administration group as compared to the IV injection group. Total blood loss, blood transfusion group, and drain output was also less but the difference was not significant. The functional assessment (WOMAC scores were equivocal and so were the complications including thromboembolic manifestations (two cases each of deep vein thrombosis (DVT and no cases of pulmonary embolism (PE. Conclusion: Intraarticular administration of TXA to prevent postoperative blood loss in TKA is a safe and effective alternative/adjunct to its IV administration.

  13. Reverse total shoulder glenoid baseplate stability with superior glenoid bone loss.

    Science.gov (United States)

    Martin, Elise J; Duquin, Thomas R; Ehrensberger, Mark T

    2017-10-01

    Superior wear of the glenoid bone is common in patients with rotator cuff arthropathy. This can become a treatment challenge for patients who require shoulder arthroplasty. In reverse shoulder arthroplasty (RSA), glenoid bone loss may affect the stability of baseplate fixation. The primary purpose of this biomechanical laboratory study was to assess the initial fixation stability of RSA glenosphere baseplates in the presence of variable amounts of superior glenoid bone loss. High-density solid rigid polyurethane foam (30 pounds/cubic foot) was machined to model the glenoid with variable superior defects that provided different levels of support (100%, 90%, 75%, and 50%) for the glenosphere baseplate. The samples were cyclically loaded (0-750 N at 1 Hz for 5000 cycles) at a 60° glenohumeral angle. The micromotion and migration of the baseplate were calculated from displacement data captured during the loading tests with an array of 3 linear variable differential transformers mounted around the baseplate. Micromotion was significantly greater in samples with 50% defects compared with those with smaller defects. Migration was significantly greater after testing for all defect sizes. Initial fixation of RSA glenosphere baseplates was significantly reduced in models with 50% bone loss on the superior edge compared with models with less bone loss in this high-density bone foam model. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. Application of the integrated analysis of safety (ISA) to sequences of Total loss of feed water in a PWR Reactor

    International Nuclear Information System (INIS)

    Moreno Chamorro, P.; Gallego Diaz, C.

    2011-01-01

    The main objective of this work is to show the current status of the implementation of integrated analysis of safety (ISA) methodology and its SCAIS associated tool (system of simulation codes for ISA) to the sequence analysis of total loss of feedwater in a PWR reactor model Westinghouse of three loops with large, dry containment.

  15. Can a mathematical model predict an individual's trait-like response to both total and partial sleep loss?

    Science.gov (United States)

    Ramakrishnan, Sridhar; Lu, Wei; Laxminarayan, Srinivas; Wesensten, Nancy J; Rupp, Tracy L; Balkin, Thomas J; Reifman, Jaques

    2015-06-01

    Humans display a trait-like response to sleep loss. However, it is not known whether this trait-like response can be captured by a mathematical model from only one sleep-loss condition to facilitate neurobehavioural performance prediction of the same individual during a different sleep-loss condition. In this paper, we investigated the extent to which the recently developed unified mathematical model of performance (UMP) captured such trait-like features for different sleep-loss conditions. We used the UMP to develop two sets of individual-specific models for 15 healthy adults who underwent two different sleep-loss challenges (order counterbalanced; separated by 2-4 weeks): (i) 64 h of total sleep deprivation (TSD) and (ii) chronic sleep restriction (CSR) of 7 days of 3 h nightly time in bed. We then quantified the extent to which models developed using psychomotor vigilance task data under TSD predicted performance data under CSR, and vice versa. The results showed that the models customized to an individual under one sleep-loss condition accurately predicted performance of the same individual under the other condition, yielding, on average, up to 50% improvement over non-individualized, group-average model predictions. This finding supports the notion that the UMP captures an individual's trait-like response to different sleep-loss conditions. © 2014 European Sleep Research Society.

  16. Loss of knee-extension strength is related to knee swelling after total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten T; Bencke, Jesper

    2010-01-01

    To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA).......To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA)....

  17. Total loss of the covering of a metallic stent during esophageal leak treatment

    Directory of Open Access Journals (Sweden)

    J.J. Villarreal-Galvan

    2013-01-01

    Full Text Available A 41-year-old man underwent a Heller myotomy due to achalasia. An unexpected puncture in the esophageal wall was identified during the procedure. A partially covered 15 cm stent (PSEMS (UltraFlex was placed at the mucosal defect. It was removed 26 days later and the endoscopic image showed esophageal tissue embedded in the covered portion of the stent. PSEMS covering loss is a rare complication that can have serious consequences.

  18. Individualized performance prediction during total sleep deprivation: accounting for trait vulnerability to sleep loss.

    Science.gov (United States)

    Ramakrishnan, Sridhar; Laxminarayan, Srinivas; Thorsley, David; Wesensten, Nancy J; Balkin, Thomas J; Reifman, Jaques

    2012-01-01

    Individual differences in vulnerability to sleep loss can be considerable, and thus, recent efforts have focused on developing individualized models for predicting the effects of sleep loss on performance. Individualized models constructed using a Bayesian formulation, which combines an individual's available performance data with a priori performance predictions from a group-average model, typically need at least 40 h of individual data before showing significant improvement over the group-average model predictions. Here, we improve upon the basic Bayesian formulation for developing individualized models by observing that individuals may be classified into three sleep-loss phenotypes: resilient, average, and vulnerable. For each phenotype, we developed a phenotype-specific group-average model and used these models to identify each individual's phenotype. We then used the phenotype-specific models within the Bayesian formulation to make individualized predictions. Results on psychomotor vigilance test data from 48 individuals indicated that, on average, ∼85% of individual phenotypes were accurately identified within 30 h of wakefulness. The percentage improvement of the proposed approach in 10-h-ahead predictions was 16% for resilient subjects and 6% for vulnerable subjects. The trade-off for these improvements was a slight decrease in prediction accuracy for average subjects.

  19. Which Route of Tranexamic Acid Administration is More Effective to Reduce Blood Loss Following Total Knee Arthroplasty?

    Science.gov (United States)

    Keyhani, Sohrab; Esmailiejah, Ali Akbar; Abbasian, Mohammad Reza; Safdari, Farshad

    2016-01-01

    The most appropriate route of tranexamic acid administration is controversial. In the current study, we compared the efficacy of intravenous (IV) and topical intra-articular tranexamic acid in reducing blood loss and transfusion rate in patients who underwent primary total knee arthroplasty. One hundred twenty 120 patients were scheduled to undergo primary total knee arthroplasty. Patients were randomly allocated to three equal groups: IV tranexamic acid (500 mg), topical tranexamic acid (3 g in 100 mL normal saline) and the control. In the topical group, half of the volume was used to irrigate the joint and the other half was injected intra-articularly. The volume of blood loss, hemoglobin (Hb) level at 24 hours postoperative, and rate of transfusion was compared between groups. The blood loss and Hb level were significantly greater and lower in the control group, respectively (P=0.031). Also, the rate of transfusion was significantly greater in the control group (P=0.013). However, IV and topical groups did not differ significantly in terms of measured variables. No patient experienced a thromboembolic event in our study. Tranexamic acid is a useful antifibrinolytic drug to reduce postoperative blood loss, Hb drop, and rate of blood transfusion in patients undergoing total knee arthroplasty. The route of tranexamic acid administration did not affect the efficacy and safety.

  20. [Intra-Articular Application of Tranexamic Acid Significantly Reduces Blood Loss and Transfusion Requirement in Primary Total Knee Arthroplasty].

    Science.gov (United States)

    Lošťák, J; Gallo, J; Špička, J; Langová, K

    2016-01-01

    PURPOSE OF THE STUDY The aim of this prospective study was to investigate the effect of topical application of tranexamic acid (TXA, Exacyl) on the amount of post-operative blood loss, and blood transfusion requirement in patients undergoing primary total knee arthroplasty (TKA). Attention was paid to early complications potentially associated with TXA administration, such as haematoma, wound exudate, or knee swelling. In addition, the economic benefit of TXA treatment was also taken into account. MATERIAL AND METHODS The study included 238 patients (85 men and 153 women) who underwent primary total knee arthroplasty (TKA) at our department between January 2013 and November 2015. A group of 119 patients (41 men and 78 women) received intraarticular TXA injections according to the treatment protocol (TXA group). A control group matched in basic characteristics to the TXA group also consisted of 119 patients. The average age in the TXA group was 69.8 years, and the most frequent indication for TKA surgery was primary knee osteoarthritis (81.5%). In each patient, post-operative volume of blood lost from drains and total blood loss including hidden blood loss were recorded, as well as post-operative haemoglobin and haematocrit levels. On discharge of each patient from hospital, the size and site of a haematoma; wound exudate, if present after post-operative day 4; joint swelling; range of motion and early revision surgery, if performed, were evaluated. Requirements of analgesic drugs after surgery were also recorded. RESULTS In the TXA group, blood losses from drains were significantly lower than in the control group (456.7 ± 270.8 vs 640.5 ±448.2; p = 0.004). The median value for blood losses from drains was lower by 22% and the average value for total blood loss, including hidden losses, was also lower than in the control group (762.4 ± 345.2 ml vs 995.5 ± 457.3 ml). The difference in the total amount of blood loss between the two groups was significant (p = 0

  1. A new topical hemostatic agent TT-173 reduces blood loss in a sheep model of total knee arthroplasty.

    Science.gov (United States)

    Centeno, Alberto; Rojas, Santiago; Arias, Belén; Miquel, Ignasi; Sánchez, Pilar; Ureta, Claudia; Rincón, Esther; López, Ramón; Murat, Jesús

    2017-12-01

    Total knee arthroplasty is associated with blood loss during the intervention and may require allogenic blood transfusion. Treatments such as tranexamic acid and fibrin sealants improved the bleeding control in several clinical trials, but the hemorrhage associated with the intervention is still significant. Thus far, very few studies have evaluated hemostatic treatments in animal models of total knee arthroplasty. This work describes a sheep model of bleeding associated with total knee arthroplasty and investigates a new class of hemostatic treatment based on recombinant tissue factor. Sheep were treated with the anticoagulant heparin, and the joint was accessed by a paramedial incision. Ligaments and menisci were eliminated and femoral condyles and tibia plateau were sectioned exposing the trabecular bone. An intra-articular drain was used to recover and quantify the blood loss during the 90-min period after treatment. The efficacy of one milligram and three milligrams of TT-173 was evaluated and compared with tranexamic acid. The occurrence of analytical alterations and systemic absorption was also investigated. Treatment with TT-173 reduced the blood loss in comparison with control or tranexamic acid. No significant differences were observed between the two doses evaluated. Moreover, a dose of six milligrams of TT-173 did not induce any clinical or analytical alteration, and significant systemic absorption was not observed. Data obtained strongly suggest that TT-173 could be useful in reducing the blood loss associated with total knee arthroplasty and without safety concerns derived from the systemic absorption of the product. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. THREE-PHASE ENERGY SUPPLY SYSTEMS SIMULATION FOR THE TOTAL POWER LOSSES COMPONENTS ASSESSMENT

    Directory of Open Access Journals (Sweden)

    D.V. Tugay

    2016-09-01

    Full Text Available Purpose. The goal is to optimize a structure of Matlab-model of the three-phase energy supply system with power active filter. The mathematical model that describes the energy supply system modes of operation which contains additional losses is proposed. Methodology. We have applied concepts of the electrical circuits theory, mathematical modeling elements based on linear algebra and vector calculus, mathematical simulation in Matlab package. Results. We have developed two models of three-phase energy supply system. The first one is based on a vector representation, and the second one on the matrix representation of energy processes. Using these models we have solved the problem of maintaining unchanged the average useful power for 279 cases of energy supply system modes of operation. Originality. We have developed methods of mathematical analysis of a three-phase energy supply systems with polyharmonic voltages and currents in the symmetric and asymmetric modes. Practical value. We have created Matlab-model of a three-phase energy supply system with automated calculation of a correction factor. It allows reducing more than one order the time for energy processes elucidation in multiphase systems.

  3. Custom total knee replacement in a dog with femoral condylar bone loss.

    Science.gov (United States)

    Liska, William D; Marcellin-Little, Denis J; Eskelinen, Esa V; Sidebotham, Christopher G; Harrysson, Ola L A; Hielm-Björkman, Anna K

    2007-06-01

    To report surgical planning, technique, and outcome of custom total knee replacement (TKR) performed to manage a medial femoral condylar nonunion in a dog. Clinical case report. A 3-year-old, 20 kg Karelian Bear Hound. Computed tomographic scan of the left pelvic limb was used to build a stereolithography model of the distal portion of the femur. The model was used to create a custom augment to replace the missing medial femoral condyle and a custom stem for intramedullary condylar cemented fixation. The augment and stem were adapted to femoral and tibial components already available. The model was used to rehearse the surgery and then the custom prosthesis was implanted. Weight bearing returned 8 hours after surgery and improved thereafter. Joint alignment was normal and prosthetic joint motion was 60-165 degrees postoperatively. The dog resumed moose hunting 3 months after surgery. Peak vertical force and impulse of the operated limb measured 17 months after surgery were 65% and 47% of the normal, contralateral limb. Based on short-term follow-up, cemented canine TKR was successfully achieved for management of a severely abnormal stifle joint. With further refinement and development of commercially available prostheses, TKR should be possible for canine patients.

  4. Comparison of topical and intravenous administration of tranexamic acid for blood loss control during total joint replacement: Review of literature

    Directory of Open Access Journals (Sweden)

    Georgi P. Georgiev

    2018-04-01

    Full Text Available Purpose: Many randomised controlled trials and meta-analysis studies have presented the efficacy of tranexamic acid (TXA without an increase of complications. However, questions still remain about the type of administration, optimal dose and secondary outcomes of TXA in total hip arthroplasty and total knee arthroplasty. The aim of this review is to summarise the existing information in literature concerning the pharmacological characteristics of TXA, forms, doses, types of application and contraindications for its use. Methods: A literature review containing 63 articles from the PubMed data starting from the first description of tranexamic acid until now was made in trying to present the existing information in a simple and effective way. Results: TXA leads to statistically significant reduction of peri and postoperative bleeding and in that way decreases blood transfusion rates and the infection risk. Topical and intravenous (IV use of TXA revealed similar results, with no increase of deep venous thrombosis. Therefore, topical TXA could be a reasonable alternative in patients with contraindications for IV application of TXA. Conclusions: Blood loss control with TXA, a synthetic analogue of the amino acid lysine, may be an excellent and safe alternative to allogeneic blood transfusion after total hip arthroplasty and total knee arthroplasty. Further studies are needed to establish the efficacy of combined IV and topical administration of TXA with regard to diminishing blood loss and reducing hospital stay. The Translational Potential of this Article: This review briefly presents the pharmacological characteristics of TXA, forms, doses, types of application and contraindications for its use with regard to diminishing blood loss and reducing hospital stay for better therapeutic strategies in orthopaedics. Keywords: Arthroplasty, Review, Tranexamic acid

  5. Process Improvement Project Using Tranexamic Acid Is Cost-Effective in Reducing Blood Loss and Transfusions After Total Hip and Total Knee Arthroplasty.

    Science.gov (United States)

    Demos, Harry A; Lin, Zilan X; Barfield, William R; Wilson, Sylvia H; Robertson, Dawn C; Pellegrini, Vincent D

    2017-08-01

    Tranexamic acid (TXA) has been associated with decreased blood loss and transfusion after total hip arthroplasty (THA) and total knee arthroplasty (TKA). The purpose of this study was to examine both transfusion utilization and the economic impact of a Process Improvement Project implementing TXA for THA and TKA. After standardization of TXA administration in THA and TKA patients, retrospective data were compared from 12 consecutive months before (group A, n = 336 procedures) and after (group B, n = 436 procedures) project initiation. TXA administration increased with project implementation (group A = 3.57%, group B = 86.01%) and was associated with reductions in perioperative hemoglobin decrement (20.2%), patients transfused (45%), and number of units transfused per patient (61.9%). Cost savings were notable per patient ($128) and annually program wide ($55,884) with the primary THA subgroup contributing the most to the savings. No increase in adverse effects was observed. Standardized administration of TXA is an effective and economically favorable blood-reduction strategy for patients undergoing elective THA or TKA. Although reduction in transfusions with TXA may be greater after TKA, the economic and clinical impact of transfusion reduction is more substantial in THA patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Possibilities and consequences of the Total Cumulative Exergy Loss method in improving the sustainability of power generation

    International Nuclear Information System (INIS)

    Stougie, Lydia; Kooi, Hedzer J. van der

    2016-01-01

    Highlights: • The TCExL method can be applied to all kinds of technological systems. • All exergy losses during the lifetime of a technological system are considered. • The results of the TCExL method are independent of time and weighting factors. • Applying the TCExL method can improve the sustainability of power generation. • The system with the lowest TCExL score is not always economically favourable. - Abstract: It is difficult to decide which power generation system is the most sustainable when environmental, economic and social sustainability aspects are taken into account. Problems with conventional environmental sustainability assessment methods are that no consensus exists about the applied models and weighting factors and that exergy losses are not considered. Economic sustainability assessment methods do not lead to results that are independent of time because they are influenced by market developments, while social sustainability assessment methods suffer from the availability and qualitative or semi-quantitative nature of data. Existing exergy analysis methods do not take into account all exergy losses and/or are extended with factors or equations that are not commonly accepted. The new Total Cumulative Exergy Loss (TCExL) method is based on fundamental thermodynamic equations and takes into account all exergy losses caused by a technological system during its life cycle, i.e. internal exergy losses, exergy losses caused by emission abatement and exergy losses related to land use. The development of the TCExL method is presented as well as the application of this method and environmental, economic and social sustainability assessment methods to two case studies: power generation in combination with LNG evaporation and Fossil versus renewable energy sources for power generation. According to the results of the assessments, large differences exist between the environmental sustainability assessment and TCExL methods in the sense that different

  7. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-01-01

    To support the development of a Probabilistic Safety Assessment (PSA) model usable in Riskinformed Applications (RIA) for Korea Standard Nuclear power Plants (KSNP), we have performed a thermal hydraulic analysis of Aggressive Secondary Cooldown (ASC) in a 2-inch Small Break Loss Of Coolant Accident (SBLOCA) with a total loss of High Pressure Safety Injection (HPSI). The present study focuses on the estimation of the success criteria of ASC, and the enhanced understanding of the detailed thermal hydraulic behavior and phenomena. The results have shown that the Reactor Coolant System (RCS) pressure can be reduced to the Low Pressure Safety Injection (LPSI) operation conditions without core damage. It was also shown that more relaxed success criteria compared to those in the previous PSA models of KSNP could be used in the new PSA model. However, it was found that the results could be affected by various parameters related with ASC operation, i.e., reference temperature for the calculation of the cooldown rate and its control method

  8. Thermal hydraulic analysis of aggressive secondary cooldown in small break loss of coolant accident with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, S. J.; Im, H. K.; Yang, J. U.

    2003-01-01

    Recently, Probabilistic Safety Assessment (PSA) has being applied to various fields as a basic technique of Risk-Informed Applications (RIA). To use RIA, the present study focuses on the detailed thermal hydraulic analyses for major accident sequences and success criteria to support a development of PSA model for Korea Standard Nuclear Power plant (KSNP). The primary purpose of the present study is to evaluate the success criteria of Aggressive Secondary Cooldown (ASC) in Small Break Loss Of Coolant Accident (SBLOCA) with total loss of High Pressure Safety Injection (HPSI) and to enhance the understanding of related thermal hydraulic behavior and phenomena. The accident scenario was 2 inch coldleg break LOCA without HPSI, with 1/2 Low Pressure Safety Injection (LPSI), and performing ASC limited by 55.6 .deg. C /hr (100 .deg. F/hr) cooldown rate at 15 minute after reactor trip, which successively reaches the LPSI condition for about 1.5hr after starting ASC operation with the Peak Cladding Temperature (PCT) of the hottest rod below the core damage criteria 1204.4 .deg. C (2200 .deg. F). In the present study, more relaxed success criteria than the previous PSA for KSNP could be generated under an assumption that operator should maintain the adequate ASC operation. However, it is necessary to evaluate uncertainties arisen from the related parameters of the ASC operation

  9. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    OpenAIRE

    Mohammadreza Moshari; Bahman Malek; Mohammadreza Minator-Sajjadi; Maryam Vosoghian; Mastaneh Dahi; Mahshid Ghasemi; Razieh Shekari

    2018-01-01

    AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion), were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B) of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (...

  10. Total projectile electron loss cross sections of U^{28+} ions in collisions with gaseous targets ranging from hydrogen to krypton

    Directory of Open Access Journals (Sweden)

    G. Weber

    2015-03-01

    Full Text Available Beam lifetimes of stored U^{28+} ions with kinetic energies of 30 and 50  MeV/u, respectively, were measured in the experimental storage ring of the GSI accelerator facility. By using the internal gas target station of the experimental storage ring, it was possible to obtain total projectile electron loss cross sections for collisions with several gaseous targets ranging from hydrogen to krypton from the beam lifetime data. The resulting experimental cross sections are compared to predictions by two theoretical approaches, namely the CTMC method and a combination of the DEPOSIT code and the RICODE program.

  11. Evaluation of feed and bleed cooling mode in case of total loss of feedwater on 900 MWe PWR

    International Nuclear Information System (INIS)

    Champ, M.; Cornille, Y.

    1989-07-01

    The physical studies carried out with the CATHARE code to assess the feed and bleed procedure developed in order to cope with the total loss of feed water on a 900 MWe PWR are presented. These studies allowed the definition of the maximum delays of intervention which would prevent the core from uncovering. Different cases of equipment availability are considered. The data generated will be used in the 900 MWe Probabilistic Safety Assessment which is under way at the Institut de Protection et de Surete Nucleaire

  12. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mohammadreza Moshari

    2018-01-01

    Full Text Available AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion, were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (mean age, 64± 6.1 years received 500 mg tranexamic acid 10 minutes before loosening of tourniquet and group B (mean age, 63.5 ± 7.7 years received 500 mg tranexamic acid through IV infusion during 6 hours from the time of tourniquet loosening (total dose of TA, 1 g in both groups. Intraoperative blood loss,postoperative drainage (in 6 and 12 hours, blood transfusion (in 48 hours, and decrease in hematocrit and hemoglobin (6 and 12 hours later, were compared between the two groups.Results: The patients in group B had lower intra- and postoperative blood loss in 6 and 12 hours and also had lower decrease in hemoglobin, and their packed cell transfusion rate was significantly lower compared to the group A.Conclusion: The findings of this study indicated that infusion administration of tranexamic acid in primary total knee arthroplasty, was more effective in the reduction of perioperative blood loss as well as need for blood transfusion in 48 hours.

  13. Lysophosphatidic Acid Acyltransferase from Coconut Endosperm Mediates the Insertion of Laurate at the sn-2 Position of Triacylglycerols in Lauric Rapeseed Oil and Can Increase Total Laurate Levels

    Science.gov (United States)

    Knutzon, Deborah S.; Hayes, Thomas R.; Wyrick, Annette; Xiong, Hui; Maelor Davies, H.; Voelker, Toni A.

    1999-01-01

    Expression of a California bay laurel (Umbellularia californica) 12:0-acyl-carrier protein thioesterase, bay thioesterase (BTE), in developing seeds of oilseed rape (Brassica napus) led to the production of oils containing up to 50% laurate. In these BTE oils, laurate is found almost exclusively at the sn-1 and sn-3 positions of the triacylglycerols (T.A. Voelker, T.R. Hayes, A.C. Cranmer, H.M. Davies [1996] Plant J 9: 229–241). Coexpression of a coconut (Cocos nucifera) 12:0-coenzyme A-preferring lysophosphatitic acid acyltransferase (D.S. Knutzon, K.D. Lardizabal, J.S. Nelsen, J.L. Bleibaum, H.M. Davies, J.G. Metz [1995] Plant Physiol 109: 999–1006) in BTE oilseed rape seeds facilitates efficient laurate deposition at the sn-2 position, resulting in the acccumulation of trilaurin. The introduction of the coconut protein into BTE oilseed rape lines with laurate above 50 mol % further increases total laurate levels. PMID:10398708

  14. On-chip grating coupler array on the SOI platform for fan-in/fan-out of multi-core fibers with low insertion loss and crosstalk

    DEFF Research Database (Denmark)

    Ding, Yunhong; Ye, Feihong; Peucheret, Christophe

    2014-01-01

    We design and fabricate a compact multi-core fiber fan-in/fan-out using a fully-etched grating coupler array on the SOI platform. Lowest coupling loss of 6.8 dB with 3 dB bandwidth of 48 nm and crosstalk lower than ×32 dB are demonstrated.......We design and fabricate a compact multi-core fiber fan-in/fan-out using a fully-etched grating coupler array on the SOI platform. Lowest coupling loss of 6.8 dB with 3 dB bandwidth of 48 nm and crosstalk lower than ×32 dB are demonstrated....

  15. Tranexamic acid administration to older patients undergoing primary total hip arthroplasty conserves hemoglobin and reduces blood loss.

    Science.gov (United States)

    El Beheiry, Hossam; Lubberdink, Ashley; Clements, Nigel; Dihllon, Kiran; Sharma, Vicky

    2018-06-01

    Tranexamic acid effects in older people are difficult to predict. This study investigated the following research questions: 1) Is tranexamic acid effective in older patients undergoing primary total hip arthroplasty (THA)? and 2) Is there a difference in the effect of tranexamic acid between younger and older patients? This was a 2-phase retrospective matched-pair study of patients who underwent THA in 2007-2013. All procedures were performed by surgeons with at least 10 years' experience as senior consultant. In the first phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients who did not receive tranexamic acid for age, sex, American Society of Anesthesiologists (ASA) classification and body mass index. In the second phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients less than 65 years of age who received tranexamic acid for sex, ASA classification and body mass index. The primary outcome measures were percent maximum decrease in hemoglobin level and estimated blood loss after surgery. In the first phase, patients who received tranexamic acid conserved postoperative hemoglobin by a mean of 10.26 g/L (standard deviation [SD] 9.89 g/L) compared to the control group ( p Tranexamic acid reduced the postoperative decrease in hemoglobin level and blood loss in older patients. Moreover, the significant hemoglobin-sparing effect of tranexamic acid in older patients was similar to that observed in younger patients.

  16. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-03-01

    Recently, Probabilistic Safety Assessment (PSA) has being applied to various fields as a basic technique of Risk-Informed Applications (RIA). The present study focuses on detailed thermal hydraulic analyses for major accident sequences and success criteria to support a development of PSA model using RIA for Korea Standard Nuclear Power plant (KSNP). The primary purpose of the present study in this year is to evaluate the success cri-teria of Aggressive Secondary Cooldown (ASC) in a Small Size Loss Of Coolant Accident (SBLOCA) without HPSI and to enhance the understanding of related thermal hydraulic behavior and phenomena. An effort was made to evaluate the system success criteria and a mission time for the recovery action by an operator to prevent the core damage for that accident scenario. The accident scenario for KSNP was a 2 inch coldleg break LOCA with a total loss of High Pressure Safety Injection (HPSI) and 1/2 Low Pressure Safety Injection (LPSI) available and perform-ing ASC limited by 55.6 .deg. C/hr (100 .deg. F/hr) cooldown rate at 15 minute after reactor trip. It successively reached the LPSI condition for about 1.5hr after starting the ASC operation with the Peak Cladding Temperature (PCT) of the hottest rod below the core damage criteria of 1204.4 .deg. C (2200 .deg. F). Sensitivity studies were performed for (1) cool-ant average temperature parameters, (2) ASC operation control method, (3) operation start time, (4) 1 inch break size. The present analysis identified thermal hydraulic phenomena and parameters affecting on the behavior, which consist of coolant break flow and inventory, parameters governing secondary heat removal, ASC operation control method, and its reference temperature parameters. In the present study, more relaxed success criteria than the previous PSA for KSNP could be generated under an assumption that an operator should maintain the ade-quate ASC operation. However, it is necessary to evaluate the uncertainties arisen from the

  17. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  18. A randomized trial of the effect of low dose epinephrine infusion in addition to tranexamic acid on blood loss during total hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, Ø.; Grevstad, U.; Mandoe, H.

    2016-01-01

    procedure. Intraoperative tranexamic acid (TXA) was administered to all subjects. The primary outcome was intraoperative blood loss directly measured by drains and weighing swabs. Secondary outcome was total blood loss at 24 h postoperatively calculated using the Gross formula. Results: Of 106 subjects...

  19. Benefits of bariatric surgery before elective total joint arthroplasty: is there a role for weight loss optimization?

    Science.gov (United States)

    Nearing, Emanuel E; Santos, Tyler M; Topolski, Mark S; Borgert, Andrew J; Kallies, Kara J; Kothari, Shanu N

    2017-03-01

    The association between obesity and osteoarthritis is well established, as is the increased risk of postoperative complications after total knee arthroplasty (TKA) and total hip arthroplasty (THA) among patients with obesity. To evaluate the outcomes after TKA/THA based on whether the surgery was performed before or after bariatric surgery. Integrated, multispecialty, community teaching hospital. The medical records of all patients who underwent bariatric surgery from 2001 to 2014 were reviewed. Statistical analysis included χ 2 test and t tests. A P valuebariatric procedure, 66 underwent TKA/THA after their bariatric procedure. TKAs/THAs were performed at a mean of 4.9±3.2 years before and 4.3±3.3 years after bariatric surgery. Body mass index for those undergoing TKA/THA after bariatric surgery was lower than those with TKA/THA before bariatric surgery (37.6±7.4 versus 43.7±5.7 kg/m 2 ; Pbariatric surgery: 81.7±33.9 min versus 117±38.1 min; Pbariatric surgery. Patients who underwent TKA/THA after bariatric surgery had lower body mass index before and 1 year after TKA/THA. Postoperative complication rates were similar. Benefits of bariatric surgery and subsequent weight loss should be considered among patients with obesity requiring TKA/THA. Optimal timing of TKA/THA and bariatric surgery has yet to be established. Copyright © 2017 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  20. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  1. Performance evaluation of a biomass boiler on the basis of heat loss method and total heat values of steam

    International Nuclear Information System (INIS)

    Munir, A.; Alvi, J.Z.; Ashfaq, S.; Ghafoor, A.

    2014-01-01

    Pakistan being an agricultural country has large resources of biomass in the form of crop residues like wood, wheat straw, rice husk, cotton sticks and bagasse. Power generation using biomass offers an excellent opportunity to overcome current scenario of energy crises. Of the all biomass resources, bagasse is one of the potential energy sources which can be successfully utilized for power generation. During the last decade, bagasse fired boilers attained major importance due to increasing prices of primary energy (e.g. fossil fuels). Performance of a bagasse fired boiler was evaluated at Shakarganj Sugar Mill, Bhone-Jhang having steam generation capacity of 80 tons h/sup -1/at 25 bar working pressure. The unit was forced circulation and bi-drum type water tube boiler which was equipped with all accessories like air heater, economizer and super-heater. Flue gas analyzer and thermocouples were used to record percent composition and temperature of flue gases respectively. Physical analysis of bagasse showed gross calorific value of bagasse as 2326 kCal kg/sup -1/. Ultimate analysis of bagasse was performed and the actual air supplied to the boiler was calculated to be 4.05 kg per kg of bagasse under the available resources of the plant. Performance evaluation of the boiler was carried out and a complete heat balance sheet was prepared to investigate the different sources of heat losses. The efficiency of the boiler was evaluated on the basis of heat losses through boiler and was found to be 56.08%. It was also determined that 2 kg of steam produced from 1 kg of bagasse under existing condition of the boiler. The performance evaluation of the boiler was also done on the basis of total heat values of steam and found to be 55.98%. The results obtained from both the methods were found almost similar. Effects of excess air, stack and ambient temperature on the efficiency of boiler have also been evaluated and presented in the manuscript. (author)

  2. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  3. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  4. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  5. The longitudinal trajectory of post-surgical % total weight loss among middle-aged women who had undergone bariatric surgery

    Directory of Open Access Journals (Sweden)

    Dong-Chul Seo

    2017-03-01

    Full Text Available Middle-aged women are at a higher risk of being obese. We examined the trajectory of post-surgical % total weight loss (%TWL among middle-aged female bariatric patients. We fitted sequential generalized estimating equations models to analyze a sample of women who received bariatric surgery in 1995–2012, aged 40–65 years at the time of surgery (N = 158,292 whose pre-operative body mass index (BMI was ≥30 kg/m2 in the Bariatric Outcomes Longitudinal Database. The %TWL computed by 100% × (pre-surgery BMI − post-surgery BMI / pre-surgery BMI showed different trajectories depending on type of surgery. For gastric banding, %TWL increased rapidly right after bariatric surgery and started to decrease around 1 year after surgery. For Roux-en-Y gastric bypass (RYGB and sleeve gastrectomy, %TWL overall did not show remarkable changes from around 1 year after surgery. The highest increase in %TWL was observed in patients whose pre-operative BMI was 40 or higher and those who had undergone RYGB (ps < 0.001. Whereas the trajectories of %TWL among patients with sleeve gastrectomy and gastric banding did not differ much between different pre-operative BMI groups, the trajectories for RYGB were notably different between different pre-operative BMI groups (ps < 0.001. Middle-aged female bariatric patients are likely to achieve the highest %TWL if they receive RYGB and if their pre-operative BMI is 40 or higher. Further research is warranted to corroborate the present study's finding on the long-term effect of different types of bariatric surgery on %TWL among middle-aged women.

  6. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  7. Evaluation of seasonality on total water intake, water loss and water balance in the general population in Greece.

    Science.gov (United States)

    Malisova, O; Bountziouka, V; Panagiotakos, D Β; Zampelas, A; Kapsokefalou, M

    2013-07-01

    Water balance is achieved when water intake from solid and fluid foods and drinking water meets water losses, mainly in sweat, urine and faeces. Seasonality, particularly in Mediterranean countries that have a hot summer, may affect water loss and consequently water balance. Water balance has not been estimated before on a population level and the effect of seasonality has not been evaluated. The present study aimed to compare water balance, intake and loss in summer and winter in a sample of the general population in Greece. The Water Balance Questionnaire (WBQ) was used to evaluate water balance, estimating water intake and loss in summer (n = 480) and in winter (n = 412) on a stratified sample of the general population in Athens, Greece. In winter, mean (SD) water balance was -63 (1478) mL/day(-1) , mean (SD)water intake was 2892 (987) mL/day(-1) and mean (quartile range) water loss was 2637 (1810-3922) mL/day(-1) . In summer, mean (SD) water balance was -58 (2150) mL/day(-1) , mean (SD) water intake was 3875 (1373) mL/day(-1) and mean (quartile range) water loss was 3635 (2365-5258) mL/day(-1) . Water balance did not differ between summer and winter (P = 0.96); however, the data distribution was different; in summer, approximately 8% more participants were falling in the low and high water balance categories. Differences in water intake from different sources were identified (P balance in summer and winter was not different. However, water intake and loss were approximately 40% higher in summer than in winter. More people were falling in the low and high water balance categories in summer when comparing the distribution on water balance in winter. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  8. Application of the integrated analysis of safety (IAS) to sequences of Total loss of feed water in a PWR Reactor; Aplicacion del Analisis Integrado de Seguridad (ISA) a Secuencias de Perdidas Total de Agua de Alimentacion en un Reactor PWR

    Energy Technology Data Exchange (ETDEWEB)

    Moreno Chamorro, P.; Gallego Diaz, C.

    2011-07-01

    The main objective of this work is to show the current status of the implementation of integrated analysis of safety (IAS) methodology and its SCAIS associated tool (system of simulation codes for IAS) to the sequence analysis of total loss of feedwater in a PWR reactor model Westinghouse of three loops with large, dry containment.

  9. The role of seasonal migration in the near-total loss of caribou on south-central Canadian Arctic Islands

    Directory of Open Access Journals (Sweden)

    Frank L. Miller

    2007-04-01

    estimated 5097 1+ yr-old caribou in 1980 to fewer than 100 1+ yr-old caribou in 1995 (Gunn & Decker, 1984; Miller, 1997; Gunn & Dragon, 1998; Gunn et al., 2006. This loss of caribou on those islands amounts to a near-total loss of a genetically distinctive group of Arctic-island caribou (e.g., Zittlau, 2004. In contrast, the estimated number of caribou in the geographic population on Boothia Peninsula appeared to increase by 1.4-fold from 4831 to 6658 1+ yr-old caribou between 1985 and 1995, although annual harvesting pressure was heavy. It was biologically impossible for the Boothia Peninsula geographic population at its 1985 estimated size to have persisted until 1995, let alone to have increased, under the estimated average annual harvest regime of 1100 1+ yr-old caribou • yr-1. There is no evidence that the Boothia Peninsula population was underestimated in 1985. It would have required a population in 1985 at least twice as great as the calculated estimate to sustain the estimated annual harvest between 1985 and 1995. An underestimate of such magnitude is too great to be probable. In our examination of the survey results, we could find no reason to question that the calculated population estimates were not reasonable approximations. The fixed-wing aerial surveys in 1980 (Gunn & Decker, 1984, 1985 (Gunn & Ashevak, 1990, and 1995 (Gunn & Dragon, 1998 were highly comparable, well designed and executed, using standard procedures for a fixed-width, strip-transect, systematic aerial survey of caribou. One of the two observers was the same experienced survey biologist in all 3 years, the second observer in 1980 was an experienced survey biologist and in 1985 and 1995 was an experienced Inuit hunter familiar with the area, and the pilot was the same on all surveys and had flown many systematic surveys of caribou on the Canadian Arctic Archipelago and mainland Canada. Helicopter searches of known caribou ranges on Prince of Wales, Russell, and Somerset islands that were

  10. Tranexamic acid reduces blood loss and blood transfusions in primary total hip arthroplasty: a prospective randomized double-blind study in 40 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Blønd, Lars; Sonne-Holm, Stig

    2003-01-01

    INTRODUCTION: We performed a prospective, randomized, double-blind study on 40 patients scheduled for primary total hip arthroplasty due to arthrosis or osteonecrosis to determine the effect of tranexamic acid on per- and postoperative blood losses and on the number of blood transfusions needed...... blood losses at removal of the drain 24 hours after the operation and the number of blood transfusions. RESULTS: Patients receiving tranexamic acid had a mean peroperative blood loss of 480 mL versus 622 mL in patients receiving placebo (p = 0.3), a postoperative blood loss of 334 mL versus 609 mL (p...... = 0.001), a total blood loss of 814 mL versus 1231 mL (p = 0.001) and a total need for 4 blood transfusions versus 25 (p = 0.04). No patient in either group had symptoms of deep venous thrombosis, pulmonary embolism or prolonged wound drainage. INTERPRETATION: Transemic acid is effective in reducing...

  11. Analysis of total productive maintenance (TPM) implementation using overall equipment effectiveness (OEE) and six big losses: A case study

    Science.gov (United States)

    Martomo, Zenithia Intan; Laksono, Pringgo Widyo

    2018-02-01

    In improving the productivity of the machine, the management of the decision or maintenance policy must be appropriate. In Spinning II unit at PT Apac Inti Corpora, there are 124 ring frame machines that often have breakdown and cause a high downtime so that the production target is not achieved, so this research was conducted on the ring frame machine. This study aims to measure the value of equipment effectiveness, find the root cause of the problem and provide suggestions for improvement. This research begins with measuring the achievement of overall equipment effectiveness (OEE) value, then identifying the six big losses that occur. The results show that the average value of OEE in the ring frame machine is 79.96%, the effectiveness value is quite low because the standard of OEE value for world class company ideally is 85%. The biggest factor that influences the low value of OEE is performance rate with percentage factor six big losses at reduced speed losses of 17.303% of all time loss. Proposed improvement actions are the application of autonomous maintenance, providing training for operators and maintenance technicians and supervising operators in the workplace.

  12. Tranexamic acid reduces blood loss and blood transfusions in primary total hip arthroplasty: a prospective randomized double-blind study in 40 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Blønd, Lars; Sonne-Holm, Stig

    2003-01-01

    INTRODUCTION: We performed a prospective, randomized, double-blind study on 40 patients scheduled for primary total hip arthroplasty due to arthrosis or osteonecrosis to determine the effect of tranexamic acid on per- and postoperative blood losses and on the number of blood transfusions needed....... PATIENTS AND METHODS: 40 patients were randomized to tranexamic acid (10 mg/kg given as a bolus intravenous injection, followed by a continuous infusion of 1 mg/kg/hour for 10 hours) or placebo (20 mL saline given intravenously) 15 minutes before the incision. We recorded the peroperative and postoperative...... blood losses at removal of the drain 24 hours after the operation and the number of blood transfusions. RESULTS: Patients receiving tranexamic acid had a mean peroperative blood loss of 480 mL versus 622 mL in patients receiving placebo (p = 0.3), a postoperative blood loss of 334 mL versus 609 mL (p...

  13. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  14. A phylogenetic analysis of basal metabolism, total evaporative water loss, and life-history among foxes from desert and mesic regions

    NARCIS (Netherlands)

    Williams, JB; Munoz-Garcia, A; Ostrowski, S; Tieleman, BI

    We measured basal metabolic rate (BMR) and total evaporative water loss (TEWL) of species of foxes that exist on the Arabian Peninsula, Blanford's fox (Vulpes cana) and two subspecies of Red fox (Vulpes vulpes). Combining these data with that on other canids from the literature, we searched for

  15. Repeatability and individual correlates of basal metabolic rate and total evaporative water loss in birds : A case study in European stonechats

    NARCIS (Netherlands)

    Versteegh, Maaike A.; Heim, Barbara; Dingemanse, Niels J.; Tieleman, B. Irene

    Basal metabolic rate (BMR) and total evaporative water loss (TEWL) are thought to have evolved in conjunction with life history traits and are often assumed to be characteristic features of an animal. Physiological traits can show large intraindividual variation at short and long timescales, yet

  16. Tranexamic acid reduces intraoperative occult blood loss and tourniquet time in obese knee osteoarthritis patients undergoing total knee arthroplasty: a prospective cohort study.

    Science.gov (United States)

    Meng, Yutong; Li, Zhirui; Gong, Ke; An, Xiao; Dong, Jiyuan; Tang, Peifu

    2018-01-01

    Obesity can result in increased blood loss, which is correlated with poor prognosis in total knee arthroplasty (TKA). Clinical application of tranexamic acid is effective in reducing blood loss in TKA. However, most previous studies focused on the effect of tranexamic acid in the whole population, neglecting patients with specific health conditions, such as obesity. We hypothesized that tranexamic acid would reduce blood loss to a greater extent in obese patients than in those of normal weight. A total of 304 patients with knee osteoarthritis treated with TKA from October 2013 to March 2015 were separated into tranexamic, non-tranexamic, obese, and non-obese groups. The demographic characteristics, surgical indices, and hematological indices were all recorded. We first investigated the ability of intravenous tranexamic acid to reduce intraoperative blood loss in knee osteoarthritis patients undergoing unilateral TKA. Second, we performed subgroup analysis to compare the effects of tranexamic acid between obese and non-obese patients separately. Of the 304 patients, 146 (52.0%) received tranexamic acid and 130 (42.8%) were obese. In the analysis of the whole group, both the actual and occult blood loss volume were lower in the tranexamic acid group (both P tranexamic acid group ( P tranexamic acid was shown to reduce theoretical and actual blood loss in both the obese and non-obese groups ( P Tranexamic acid reduced occult blood loss and tourniquet time in the obese group ( P 0.05). Tranexamic acid can reduce occult blood loss and tourniquet time in obese patients to a greater extent than in patients of normal weight. Therefore, obese knee osteoarthritis patients undergoing TKA can benefit more from tranexamic acid.

  17. Synergistic effects of intravenous and intra-articular tranexamic acid on reducing hemoglobin loss in revision total knee arthroplasty: a prospective, randomized, controlled study.

    Science.gov (United States)

    Yuan, Xiangwei; Wang, Jiaxing; Wang, Qiaojie; Zhang, Xianlong

    2018-04-01

    Tranexamic acid decreases blood loss in primary total knee arthroplasty, and no related prospective randomized clinical trials have been conducted to evaluate the effectiveness and safety of tranexamic acid in revision total knee arthroplasty. Thus, we conducted this work to evaluate the synergistic effects of intravenous plus intra-articular tranexamic acid on reducing hemoglobin loss compared with intra-articular tranexamic acid alone in revision total knee arthroplasty. This prospective, controlled study randomized 96 patients undergoing revision total knee arthroplasty into two groups: an intravenous plus intra-articular tranexamic acid group (48 patients who received 20 mg/kg intravenous tranexamic acid and 3.0 g intra-articular tranexamic acid); and an intra-articular tranexamic acid alone group (48 patients who received the same intravenous volume of normal saline and 3.0 g intra-articular tranexamic acid). The primary outcome was hemoglobin loss. Secondary outcomes included the volume of drain output, the percentage of patients who received transfusions, the number of units transfused, and thromboembolic events. The baseline data, preoperative hemoglobin, and tourniquet time were similar in both groups. There was significantly less hemoglobin loss in the intravenous plus intra-articular tranexamic acid group compared with the intra-articular tranexamic acid alone group (2.7 ± 0.6 g/dL and 3.7 ± 0.7 g/dL; p tranexamic acid alone group, the intravenous plus intra-articular tranexamic acid group also had significantly less drain output, fewer patients who received transfusions, and fewer units transfused (all p tranexamic acid alone, combined intravenous plus intra-articular tranexamic acid significantly reduced hemoglobin loss and the need for transfusion without an apparent increase in thromboembolic events in patients who underwent revision total knee arthroplasty. © 2018 AABB.

  18. Total 'shrink' losses, and where they occur, in commercially sized silage piles constructed from immature and mature cereal crops.

    Science.gov (United States)

    Robinson, P H; Swanepoel, N; Heguy, J M; Price, P; Meyer, D M

    2016-07-15

    Silage 'shrink' (i.e., fresh chop crop lost between ensiling and feedout) represents losses of potential animal nutrients which degrade air quality as volatile carbon compounds. Regulatory efforts have, in some cases, resulted in semi-mandatory mitigations (i.e., dairy farmers select a minimum number of mitigations from a list) to reduce silage shrink, mitigations often based on limited data of questionable relevance to large commercial silage piles where silage shrink may or may not be a problem of a magnitude equal to that assumed. Silage 'shrink' is generally ill defined, but can be expressed as losses of wet weight (WW), oven dry matter (oDM), and oDM corrected for volatiles lost during oven drying (vcoDM). As no research has documented shrink in large cereal silage piles, 6 piles ranging from 1456 to 6297tonnes (as built) were used. Three used cereal cut at an immature stage and three at a mature stage. Physiologically immature silages had generally higher (Plosses (vcoDM) of large well managed cereal silage piles were relatively low, and a lower potential contributor to aerosol emissions of volatile carbon compounds than has often been assumed. Losses from the silage mass and the exposed silage face were approximately equal contributors to vcoDM shrink. Mitigations to reduce these relatively low emission levels of volatile organic compounds from cereal silage piles should focus on the ensiled mass and the exposed silage face. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. [Loss of total 5-methylcytosine from the genome during cell culture aging coincides with the Hayflick limit].

    Science.gov (United States)

    Mazin, A L

    1993-01-01

    Analyzing the data about the age-related 5-methylcytosine (5mC) loss from DNA of cell cultures, the following conclusions have been made: 1. The rate of 5mC loss from DNA does not depend on the cell donor age; it remains constant during the logarithmic phase of cell growth, and may vary significantly in different cell lines. 2. The rate is inversely proportional to their Hayflick limit and to the species lifespan of cell donors. 3. In immortal cell lines the 5mC content in DNA is stable or increases with aging. 4. Hayflick limit estimations coincide with or are lower than the number of cell population doublings that corresponds to all 5mC loss from cell genome. A simple and fast method has been proposed for Hayflick limit prognostication by analysis of the rate of DNA hypomethylation. It may be used for early diagnosis of precrisis and immortal cell lines. Evidence has been obtained that age-dependent 5mC loss from DNA is the result of accumulating 5mC-->T+C substitutions that occur during DNA methylation in every cell division. The loss of all genomic 5mC residues during the lifespan may correspond to accumulation of about 3 x 10(6) 5mC-->T transitions or, on average, one mutation per gene. This may be one of the main reasons of the "catastrophe of errors" and cessation of cell proliferation. It is calculated that the rate of 5mC-->T transitions in normal cells may be 2.3 x 10(-5) per site in each cell doubling in human, 6 x 10(-5) in hamster, and 4.6 x 10(-4) in mouse. DNA methylation as a generator of mutations may be a "counter" of cell divisions and thus be one of the molecular mechanisms of the Hayflick phenomenon. The conclusion is made that the DNA methylation system may be considered as a genetically programmed mechanism for accumulating mutations during cell aging.

  20. Total adiponectin and adiponectin multimeric complexes in relation to weight loss-induced improvements in insulin sensitivity in obese women

    DEFF Research Database (Denmark)

    Polak, J.; Kovacova, Z.; Holst, C.

    2008-01-01

    , and LMW). The HMW form was suggested to be closely associated with insulin sensitivity. This study investigated whether diet-induced changes in insulin sensitivity were associated with changes in adiponectin multimeric complexes. SUBJECTS: Twenty obese women with highest and twenty obese women with lowest...... diet induced changes in insulin sensitivity (responders and non-responders respectively), matched for weight loss (body mass index (BMI)=34.5 (s.d. 2.9) resp. 36.5 kg/m(2) (s.d. 4.0) for responders and non-responders), were selected from 292 women who underwent a 10-week low-caloric diet (LCD; 600 kcal...

  1. Relative contributions of wind and water erosion to total soil loss and its effect on soil properties in sloping croplands of the Chinese Loess Plateau.

    Science.gov (United States)

    Tuo, Dengfeng; Xu, Mingxiang; Gao, Guangyao

    2018-08-15

    Wind and water erosion are two dominant types of erosion that lead to soil and nutrient losses. Wind and water erosion may occur simultaneously to varying extents in semi-arid regions. The contributions of wind and water erosion to total erosion and their effects on soil quality, however, remains elusive. We used cesium-137 ( 137 Cs) inventories to estimate the total soil erosion and used the Revised Universal Soil Loss Equation (RUSLE) to quantify water erosion in sloping croplands. Wind erosion was estimated from the subtraction of the two. We also used 137 Cs inventories to calculate total soil erosion and validate the relationships of the soil quality and erosion at different slope aspects and positions. The results showed that wind erosion (1460tkm -2 a -1 ) on northwest-facing slope was responsible for approximately 39.7% of the total soil loss, and water erosion (2216tkm -2 a -1 ) accounted for approximately 60.3%. The erosion rates were 58.8% higher on northwest- than on southeast-facing slopes. Northwest-facing slopes had lower soil organic carbon, total nitrogen, clay, and silt contents than southeast-facing slopes, and thus, the 137 Cs inventories were lower, and the total soil erosions were higher on the northwest-facing slopes. The variations in soil physicochemical properties were related to total soil erosion. The lowest 137 Cs inventories and nutrient contents were recorded at the upper positions on the northwest-facing slopes due to the successive occurrence of more severe wind and water erosion at the same site. The results indicated that wind and water could accelerate the spatial variability of erosion rate and soil properties and cause serious decreases in the nutrient contents in sloping fields. Our research could help researchers develop soil strategies to reduce soil erosion according to the dominant erosion type when it occurs in a hilly agricultural area. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  3. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  4. Outcome of revision total knee arthroplasty with the use of trabecular metal cone for reconstruction of severe bone loss at the proximal tibia

    DEFF Research Database (Denmark)

    Jensen, Claus L; Olsen, Nikolaj Winther; Schrøder, Henrik M

    2014-01-01

    technology (TMT) cones for the reconstruction of tibial bone loss at the time of rTKA. METHODS: Thirty-six patients had rTKA with the use of a TMT Cone. Bone loss was classified according to the AORI classification and 25% of the patients suffered from T3 AORI defects and 75% of the patients from T2 AORI...... defects. Implants used were from the NexGen series. At follow-up, radiographs were evaluated according to the Knee Society Roentgenographic Scoring System. Knee and function score was calculated using the Knee Society Clinical Rating System. Average follow-up time was 47 months (range 3-84 months......BACKGROUND: The relative effectiveness of different methods for reconstructing large bone loss at the proximal tibia in revision total knee arthroplasty (rTKA) has not been established. The aim of this study was to evaluate the clinical and radiological outcome after the use of trabecular metal...

  5. Analysis of cell flow and cell loss following X-irradiation using sequential investigation of the total number of cells in the various parts of the cell cycle

    International Nuclear Information System (INIS)

    Skog, S.; Tribukait, B.

    1985-01-01

    The cell flow and cell loss of an in vivo growing Ehrlich ascites tumour were calculated by sequential estimation of changes in total number of cells in the cell cycle compartments. Normal growth was compared with the grossly disturbed cell flow evident after a 5 Gy X-irradiation. The doubling time of normal, exponentially growing cells was 24 hr. The generation time was 21 hr and the potential doubling time was 21 hr. Thus, the growth fraction was 1.0 and the cell loss rate about 0.5%/hr. Following irradiation, a transiently increased relative outflow rate from all cell cycle compartments was found at about 3 and 40 hr, and from S phase at 24 hr after irradiation. Increase in cell loss as well as non-viable cells was observed at 24 hr after irradiation at the time of release of the irradiation-induced G 2 blockage. The experiments show the applicability and limitations of cell flow and cell loss calculations by sequential analysis of the total number of cells in the various parts of the cell cycle. (author)

  6. The efficiency and safety of fibrin sealant for reducing blood loss in primary total hip arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Zhiyuan; Xiao, Lin; Guo, Hao; Zhao, Guanghui; Ma, Jianbing

    2017-01-01

    Total hip arthroplasty (THA) is associated with substantial blood loss. The objective of present systematic review and meta-analysis is to provide evidence from randomized controlled trials (RCTs) on the efficiency and safety of administration of fibrin sealant (FS) for reducing blood loss in patients undergoing primary THA. Potential relevant studies were identified from electronic databases including Medline, PubMed, Embase, ScienceDirect, web of science and Cochrane Library. Gray academic studies were also identified from the reference list of included studies. There was no language restriction. Pooling of data was carried out by using RevMan 5.1. Six randomized controlled trials (RCTs) met the inclusion criteria. Current meta-analysis indicated that there were significant differences in terms of total blood loss (MD = -153.77, 95% CI: -287.21 to -20.34, P = 0.02), postoperative hemoglobin level (MD = -0.25, 95% CI: -0.46 to -0.05, P = 0.02) and transfusion rate (RD = -0.12, 95% CI: -0.22 to -0.03, P = 0.01) between groups. No significant differences were found regarding the incidence of deep venous thrombosis (DVT) (RD = 0.00, 95% CI: -0.01to 0.01, P = 0.51) or other side effects. Administration of fibrin sealant in total hip arthroplasty may reduce total blood loss, postoperative hemoglobin decline and transfusion requirements. Moreover, no adverse effect was related to FS. Due to the limited quality of the evidence currently available, higher quality RCTs are required. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Predicting Factors for Allogeneic Blood Transfusion and Excessive Postoperative Blood Loss after Single Low-Dosage Intra-Articular Tranexamic Acid Application in Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Paphon Sa-ngasoongsong

    2017-01-01

    Full Text Available Background. Recently, intra-articular tranexamic acid (IA-TXA application has become a popular method for perioperative blood loss (PBL reduction in total knee replacement (TKR. Nevertheless, through our knowledge, no previous studies had shown the correlation perioperative factors and the risk of excessive PBL or need of blood transfusion (BT after IA-TXA. Materials and Methods. A retrospective study was conducted in patients underwent 299 primary TKRs, using IA-TXA, during 2-year period (2013-2014. Patient’s characteristic and perioperative data were reviewed and collected. PBL was measured as total hemoglobin loss (THL, estimated total blood loss (ETBL, and drainage volume per kg (DV/kg. Excessive PBL was defined as PBL that exceeded 90th percentile. Results. From multivariate analysis, low preoperative hemoglobin (Hb level and body mass index (BMI were the significant predictors of postoperative BT (p<0.0001 and 0.003, resp.. Excessive THL significant associated with preoperative Hb (p<0.0001. Excessive ETBL significantly associated with preoperative Hb, height, preoperative range-of-motion, and creatinine clearance (p<0.05 all. Low BMI and large prosthesis size were the significant predictors of excessive DV/kg (p=0.0001 and 0.002, resp.. Conclusions. Low preoperative Hb and BMI were the significant risks of postoperative transfusion after TKR with IA-TXA. Moreover, multiple perioperative factors could result in higher PBL.

  8. Use of Tranexamic acid is a cost effective method in preventing blood loss during and after total knee replacement

    Directory of Open Access Journals (Sweden)

    Umer Chaudhry Muhammad

    2011-05-01

    Full Text Available Abstract Background & Purpose Allogenic blood transfusion in elective orthopaedic surgery is best avoided owing to its associated risks. Total knee replacement often requires blood transfusion, more so when bilateral surgery is performed. Many strategies are currently being employed to reduce the amount of peri-operative allogenic transfusions. Anti-fibrinolytic compounds such as aminocaproic acid and tranexamic acid have been used systemically in perioperative settings with promising results. This study aimed to evaluate the effectiveness of tranexamic acid in reducing allogenic blood transfusion in total knee replacement surgery. Methodology This was a retrospective cohort study conducted on patients undergoing total knee replacement during the time period November 2005 to November 2008. Study population was 99 patients, of which 70 underwent unilateral and 29 bilateral knee replacement. Forty-seven patients with 62 (49.5% knees (group-I had received tranexamic acid (by surgeon preference while the remaining fifty-two patients with 66 (51.5% knees (group-II had did not received any tranexamic acid either pre- or post-operatively. Results The mean drop in the post-operative haemoglobin concentration in Group-II for unilateral and bilateral cases was 1.79 gm/dl and 2.21 gm/dl, with a mean post-operative drainage of 1828 ml (unilateral and 2695 ml (bilateral. In comparison, the mean drop in the post-op haemoglobin in Group-I was 1.49 gm/dl (unilateral and 1.94 gm/dl (bilateral, with a mean drainage of 826 ml (unilateral and 1288 ml (bilateral (p-value Interpretation Tranexamic acid is effective in reducing post-operative drainage and requirement of blood transfusion after knee replacement.

  9. Avaliação da perda sanguínea na artroplastia total do joelho com e sem soltura do torniquete Blood loss in total knee arthroplasty with and without tourniquet release

    Directory of Open Access Journals (Sweden)

    José Wanderley Vasconcelos

    2011-01-01

    Full Text Available OBJETIVO: Avaliar a perda sanguínea em pacientes submetidos à artroplastia total cimentada do joelho com e sem soltura trans-operatória do torniquete pneumático para a hemostasia. MÉTODOS: Foram estudados 72 pacientes submetidos à artroplastia total, num total de 80 joelhos, divididos em dois grupos: Grupo 1 onde se manteve o torniquete pneumático até a sutura e curativo da ferida operatória, e Grupo 2 onde foi realizada a soltura do torniquete pneumático após a cimentação da prótese, com realização de hemostasia direta, antes da sutura e curativo. Os pacientes foram avaliados quanto ao sangramento pelo dreno de sucção e à contagem de hemoglobina e hematócrito, considerando os intervalos de duas, 24 e 48 horas de pós-operatório. RESULTADOS: Não houve diferença significante entre os dois grupos quanto ao sangramento pós-operatório e decréscimo dos parâmetros hematimétricos. Somente um paciente do Grupo 2 necessitou transfusão de concentrado de hemáceas no pós-operatório. CONCLUSÃO: O sangramento pós-operatório na ATJ mostrou-se igual com e sem a soltura do torniquete pneumático para a realização da hemostasia.OBJECTIVE: To evaluate blood loss in patients submitted to cemented total knee arthroplasty with and without perioperative tourniquet release for hemostasis. METHODS: Seventy-two patients (eighty knees were submitted to total knee arthroplasty, allocated into two groups: in Group 1, in which the pneumatic tourniquet was maintained until suture and dressing of the operated wound, and Group 2, in which the pneumatic tourniquet was released intraoperatively after cementing the prosthesis, with direct hemostasis, before the suture and dressing. The patients were evaluated for blood loss by the suction drain, and hemoglobin and hematocrit counts, at intervals of 2, 24 and 48 hours in the postoperative period tube. RESULTS: There was no significant difference between the groups in terms of postoperative blood

  10. Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?

    Science.gov (United States)

    Cyndari, Karen I; Goodheart, Jacklyn R; Miller, Mark A; Oest, Megan E; Damron, Timothy A; Mann, Kenneth A

    2017-07-01

    Loss of mechanical interlock between cement and bone with in vivo service has been recently quantified for functioning, nonrevised, cemented total knee arthroplasties (TKAs). The cause of interlocking trabecular resorption is not known. The goal of this study is to quantify the distribution of PE debris at the cement-bone interface and determine if polyethylene (PE) debris is locally associated with loss of interlock. Fresh, nonrevised, postmortem-retrieved TKAs (n = 8) were obtained en bloc. Laboratory-prepared constructs (n = 2) served as negative controls. The intact cement-bone interface of each proximal tibia was embedded in Spurr's resin, sectioned, and imaged under polarized light to identify birefringent PE particles. PE wear particle number density was quantified at the cement-bone interface and distal to the interface, and then compared with local loss of cement-bone interlock. The average PE particle number density for postmortem-retrieved TKAs ranged from 8.6 (1.3) to 24.9 (3.1) particles/mm 2 (standard error) but was weakly correlated with years in service. The average particle number density was twice as high as distal (>5mm) to the interface compared to at the interface. The local loss of interlock at the interface was not related to the presence, absence, or particle density of PE. PE debris can migrate extensively along the cement-bone interface of well-fixed tibial components. However, the amount of local bone loss at the cement-bone interface was not correlated with the amount of PE debris at the interface, suggesting that the observed loss of trabecular interlock in these well-fixed TKAs may be due to alternative factors. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Fitness-related differences in the rate of whole-body total heat loss in exercising young healthy women are heat-load dependent.

    Science.gov (United States)

    Lamarche, Dallon T; Notley, Sean R; Poirier, Martin P; Kenny, Glen P

    2018-03-01

    What is the central question of this study? Aerobic fitness modulates heat loss, albeit the heat load at which fitness-related differences occur in young healthy women remains unclear. What is the main finding and its importance? We demonstrate using direct calorimetry that fitness modulates heat loss in a heat-load dependent manner, with differences occurring between young women of low and high fitness and matched physical characteristics when the metabolic heat load is at least 400 W in hot, dry conditions. Although fitness has been known for some time to modulate heat loss, our findings define the metabolic heat load at which fitness-related differences occur. Aerobic fitness has recently been shown to alter heat loss capacity in a heat-load dependent manner in young men. However, given that sex-related differences in heat loss capacity exist, it is unclear whether this response is consistent in women. We therefore assessed whole-body total heat loss in young (21 ± 3 years old) healthy women matched for physical characteristics, but with low (low-fit; 35.8 ± 4.5 ml O 2  kg -1  min -1 ) or high aerobic fitness (high-fit; 53.1 ± 5.1 ml O 2  kg -1  min -1 ; both n = 8; indexed by peak oxygen consumption), during three 30 min bouts of cycling performed at increasing rates of metabolic heat production of 250 (Ex1), 325 (Ex2) and 400 W (Ex3), each separated by a 15 min recovery, in hot, dry conditions (40°C, 11% relative humidity). Whole-body total heat loss (evaporative ± dry heat exchange) and metabolic heat production were measured using direct and indirect calorimetry, respectively. Body heat content was measured as the temporal summation of heat production and loss. Total heat loss did not differ during Ex1 (low-fit, 215 ± 16 W; high-fit, 231 ± 20 W; P > 0.05) and Ex2 (low-fit, 278 ± 15 W; high-fit, 301 ± 20 W; P > 0.05), but was lower in the low-fit (316 ± 21 W) compared with the high-fit women (359 ± 32

  12. Total body calcium by neutron activation analysis in normals and osteoporotic populations: a discriminator of significant bone mass loss

    International Nuclear Information System (INIS)

    Ott, S.M.; Murano, R.; Lewellen, T.K.; Nelp, W.B.; Chesnut, C.M.

    1983-01-01

    Measurements of total body calcium by neutron activation (TBC) in 94 normal individuals and 86 osteoporotic patients are reported. The ability of TBC to discriminate normal from osteoporotic females was evaluated with decision analysis. Bone mineral content (BMC) by single-photon absorptiometry was also measured. TBC was higher in males (range 826 to 1363 gm vs 537 to 1054 in females) and correlated with height in all normals. In females over age 55 there was a negative correlation with age. Thus, for normals an algorithm was derived to allow comparison between measured TBC and that predicted by sex, age, and height (TBCp). In the 28 normal females over age 55, the TBC was 764 +/- 115 gm vs. 616 +/- 90 in the osteoporotics. In 63 of the osteoporotic females an estimated height, from tibial length, was used to predict TBC. In normals the TBC/TBCp ratio was 1.00 +/- 0.12, whereas in osteoporotic females it was 0.80 +/- 0.12. A receiver operating characteristic curve showed better discrimination of osteoporosis with TBC/TBCp than with wrist BMC. By using Bayes' theorem, with a 25% prevalence of osteoporosis (estimate for postmenopausal women), the posttest probability of disease was 90% when the TBC/TBCp ratio was less than 0.84. The authors conclude that a low TBC/TBCp ratio is very helpful in determining osteoporosis

  13. Dorsolateral prefrontal cortex N-acetylaspartate/total creatine (NAA/tCr) loss in male recreational cannabis users.

    Science.gov (United States)

    Hermann, Derik; Sartorius, Alexander; Welzel, Helga; Walter, Sigrid; Skopp, Gisela; Ende, Gabriele; Mann, Karl

    2007-06-01

    Cannabinoids present neurotoxic and neuroprotective properties in in vitro studies, inconsistent alterations in human neuroimaging studies, neuropsychological deficits, and an increased risk for psychotic episodes. Proton magnetic resonance spectroscopy ((1)H-MRS), neuropsychological testing, and hair analysis for cannabinoids was performed in 13 male nontreatment-seeking recreational cannabis users and 13 male control subjects. A significantly diminished N-acetylaspartate/total creatine (NAA/tCr) ratio in the dorsolateral prefrontal cortex (DLPFC) was observed in cannabis users (p = .0003). The NAA/tCr in the putamen/globus pallidum region correlated significantly with cannabidiol (R(2) = .66, p = .004). Results of the Wisconsin Card Sorting test, Trail making Test, and D2 test for attention were influenced by cannabinoids. Chronic recreational cannabis use is associated with an indication of diminished neuronal and axonal integrity in the DLPFC in this study. As chronic cannabis use is a risk factor for psychosis, these results are interesting because diminished NAA/tCr ratios in the DLPFC and neuropsychological deficits were also reported in schizophrenia. The strong positive correlation of NAA/tCr and cannabidiol in the putamen/globus pallidum is in line with neuroprotective properties of cannabidiol, which were also observed in in vitro model studies of Parkinson's disease.

  14. Tranexamic acid reduces blood loss and need of blood transfusion in total knee arthroplasty: A prospective, randomized, double-blind study in Indian population

    Directory of Open Access Journals (Sweden)

    Abhishek Shinde

    2015-01-01

    Full Text Available Introduction: For quite a few years, tranexamic acid (TEA has been used during total knee arthroplasty (TKA to reduce blood loss. However, no consensus exits regarding its timing and doses. Materials and Methods: We conducted a prospective, randomized double-blinded study of 56 patients in the Indian population undergoing TKA from 2011 to 2012. A dose of 10 mg/kg body weight of TEA (three doses was given in one group and normal saline was administered in the other. Results: The mean blood loss in the TEA unilateral group was 295 mL ± 218 mL and in the placebo group was 482 mL ± 186 mL (P < 0.005. In the bilateral TEA group, the mean blood loss was 596 mL ± 235 mL and in the placebo group was 1349 mL ± 41 mL (P < 0.005. Conclusion: The number of patients requiring blood transfusion reduced substantially. There was no increase in the risk of deep vein thrombosis (DVT and pulmonary embolism. TEA reduces intraoperative and postoperative blood loss and thus reduces the need of allogenic blood transfusion.

  15. No Effect of a Bipolar Sealer on Total Blood Loss or Blood Transfusion in Nonseptic Revision Knee Arthroplasty-A Prospective Study With Matched Retrospective Controls.

    Science.gov (United States)

    Nielsen, Christian Skovgaard; Gromov, Kirill; Jans, Øivind; Troelsen, Anders; Husted, Henrik

    2017-01-01

    Postoperative anemia is frequent after revision of total knee arthroplasty (TKA) with reported transfusion rates up to 83%. Despite increased efforts of reducing blood loss and enhancing fast recovery within the fast-track setup, a considerable transfusion rate is still evident. The aim of this study was therefore to evaluate the effect of a bipolar sealer on blood loss and transfusion in revision TKA. In this single-center prospective cohort study with retrospective controls, 51 patients were enrolled in a fast-track setup for revision TKA without the use of a tourniquet. Twenty-five prospectively enrolled patients received treatment with both a bipolar sealer and electrocautery, whereas 26 patients had received treatment with a conventional electrocautery only in the retrospective group. No significant differences were found neither for calculated blood loss, with 1397 (standard deviation, ± 452) mL in the bipolar sealer group vs 1452 (SD, ± 530) mL in the control group (P = .66), nor for blood transfusion rates of 53% and 46% (P = .89), respectively. Four controls were readmitted within 90 days follow-up. The use of a bipolar sealer in a TKA revision setting without the use of a tourniquet did not reduce blood loss or blood transfusion rates. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  17. No Effect of a Bipolar Sealer on Total Blood Loss or Blood Transfusion in Nonseptic Revision Knee Arthroplasty-A Prospective Study With Matched Retrospective Controls

    DEFF Research Database (Denmark)

    Nielsen, Christian Skovgaard; Gromov, Kirill; Jans, Øivind

    2017-01-01

    deviation, ± 452) mL in the bipolar sealer group vs 1452 (SD, ± 530) mL in the control group (P = .66), nor for blood transfusion rates of 53% and 46% (P = .89), respectively. Four controls were readmitted within 90 days follow-up. CONCLUSION: The use of a bipolar sealer in a TKA revision setting without......BACKGROUND: Postoperative anemia is frequent after revision of total knee arthroplasty (TKA) with reported transfusion rates up to 83%. Despite increased efforts of reducing blood loss and enhancing fast recovery within the fast-track setup, a considerable transfusion rate is still evident. The aim......-five prospectively enrolled patients received treatment with both a bipolar sealer and electrocautery, whereas 26 patients had received treatment with a conventional electrocautery only in the retrospective group. RESULTS: No significant differences were found neither for calculated blood loss, with 1397 (standard...

  18. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  19. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  20. Topical fibrin sealant versus intravenous tranexamic acid for reducing blood loss following total knee arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2016-08-01

    Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  2. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  3. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  4. The impact of pre-operative weight loss on incidence of surgical site infection and readmission rates after total joint arthroplasty.

    Science.gov (United States)

    Inacio, Maria C S; Kritz-Silverstein, Donna; Raman, Rema; Macera, Caroline A; Nichols, Jeanne F; Shaffer, Richard A; Fithian, Donald C

    2014-03-01

    This study characterized a cohort of obese total hip arthroplasty (THA) and total knee arthroplasty (TKA) patients (1/1/2008-12/31/2010) and evaluated whether a clinically significant amount of pre-operative weight loss (5% decrease in body weight) is associated with a decreased risk of surgical site infections (SSI) and readmissions post-surgery. 10,718 TKAs and 4066 THAs were identified. During the one year pre-TKA 7.6% of patients gained weight, 12.4% lost weight, and 79.9% remained the same. In the one year pre-THA, 6.3% of patients gained weight, 18.0% lost weight, and 75.7% remained the same. In TKAs and THAs, after adjusting for covariates, the risk of SSI and readmission was not significantly different in the patients who gained or lost weight pre-operatively compared to those who remained the same. © 2013.

  5. Effect of ensiling process of total mixed ration on fermentation profile, nutrient loss and in situ ruminal degradation characteristics of diet.

    Science.gov (United States)

    Miyaji, Makoto; Matsuyama, Hiroki; Nonaka, Kazuhisa

    2017-01-01

    This experiment aimed to determine the changes in chemical composition, fermentation profile, in situ disappearance characteristics, and nutrient losses of ensiled total mixed ration (TMR) containing steam-flaked corn or brown rice (BR) during storage. TMRs for dairy cows, containing either steam-flaked corn or BR at 31.9% with 15.2% rye silage, 40.5% alfalfa silage, 5.0% beet pulp and 7.0% soybean meal, were prepared (dry matter (DM) basis). Each TMR was placed in a plastic drum silo, stored at 23°C in an air-conditioned room and sampled 0, 7, 14, 30, 90 and 210 days after preparation. In both grain sources, the fermentation products increased, while DM and starch storage losses increased and starch content greatly decreased during storage. The rapidly degradable fraction and effective ruminal degradability of DM, crude protein and starch increased during storage. These changes of dietary characteristics were large during 30 days of storage, but small after 90 days of storage. Replacing corn with BR led to increased fermentation products, starch loss and effective ruminal degradability of the ensiled TMR. These results indicate that the ensiling process of TMR changes the dietary characteristics and replacing corn with BR in TMR had a large impact on these dietary characteristics. © 2016 Japanese Society of Animal Science.

  6. Genome-wide retroviral insertional tagging of genes involved in cancer in Cdkn2a-deficient mice

    DEFF Research Database (Denmark)

    Lund, Anders H; Turner, Geoffrey; Trubetskoy, Alla

    2002-01-01

    We have used large-scale insertional mutagenesis to identify functional landmarks relevant to cancer in the recently completed mouse genome sequence. We infected Cdkn2a(-/-) mice with Moloney murine leukemia virus (MoMuLV) to screen for loci that can participate in tumorigenesis in collaboration...... retroviral integration sites and mapped them against the mouse genome sequence databases from Celera and Ensembl. In addition to 17 insertions targeting gene loci known to be cancer-related, we identified a total of 37 new common insertion sites (CISs), of which 8 encode components of signaling pathways...... that are involved in cancer. The effectiveness of large-scale insertional mutagenesis in a sensitized genetic background is demonstrated by the preference for activation of MAP kinase signaling, collaborating with Cdkn2a loss in generating the lymphoid and myeloid tumors. Collectively, our results show that large...

  7. Tranexamic Acid Safely Reduced Blood Loss in Hemi- and Total Hip Arthroplasty for Acute Femoral Neck Fracture: A Randomized Clinical Trial.

    Science.gov (United States)

    Watts, Chad D; Houdek, Matthew T; Sems, S Andrew; Cross, William W; Pagnano, Mark W

    2017-07-01

    We aimed to determine whether (1) tranexamic acid (TXA) reduces the incidence of transfusion (2) TXA reduces the calculated blood loss, and (3) there are any observable differences in 30- and 90-day complications with TXA administration during arthroplasty for femoral neck fracture (FNF). Prospective, double-blinded, randomized controlled trial. Level 1 Academic Trauma Center. One hundred thirty-eight patients who presented with a low-energy, isolated, FNF (AO 31B) treated with either hemi- or total hip arthroplasty within 72 hours of injury were randomized to either the TXA group (69 patients) or placebo group (69 patients). In the TXA group, patients received 2 doses of 15 mg/kg intravenous TXA dissolved in 100 mL of saline, each administered over 10 minutes; 1 dose just before incision, and the second at wound closure. In the placebo group, 100 mL of saline solution was administered in a similar fashion. Perioperative care was otherwise standardized including conservative transfusion criteria. Our primary outcome was to determine the proportion of patients who underwent blood transfusion during hospitalization. Secondary outcomes were calculated blood loss, number of units transfused during hospitalization, and incidence of adverse events at 30 and 90 days including thromboembolic event, wound complications, reoperation, hospital readmission, and all-cause mortality. TXA reduced mean incidence of transfusion by 305 mL (P = 0.0005). There was a trend toward decreased transfusion rate in the TXA group (17% vs. 26%, P = 0.22). TXA was safe with no differences in adverse events at 30 and 90 days. This randomized clinical trial found that TXA administration safely reduced blood loss with a tendency for decreased transfusion rate and total blood product consumption for patients undergoing hip arthroplasty for acute FNF. More studies are needed to further ascertain the role of TXA in the management of patients with FNF. Therapeutic Level I. See Instructions for Authors

  8. Disparities in total knee replacement: Population losses in quality-adjusted life years due to differential offer, acceptance, and complication rates for Black Americans.

    Science.gov (United States)

    Kerman, Hannah M; Smith, Savannah R; Smith, Karen C; Collins, Jamie E; Suter, Lisa G; Katz, Jeffrey N; Losina, Elena

    2018-01-24

    Total knee replacement (TKR) is an effective treatment for end-stage knee osteoarthritis (OA). American racial minorities undergo fewer TKRs than Whites. We estimated quality-adjusted life years (QALYs) lost for Black knee OA patients due to differences in TKR offer, acceptance, and complication rates. We used the Osteoarthritis Policy Model, a computer simulation of knee OA, to predict QALY outcomes for Black and White knee OA patients with and without TKR. We estimated per-person QALYs gained from TKR as the difference between QALYs with current TKR use and QALYs when no TKR was performed. We estimated average, per-person QALY losses in Blacks as the difference between QALYs gained with White rates of TKR and QALYs gained with Black rates of TKR. We calculated population-level QALY losses by multiplying per-person QALY losses by the number of persons with advanced knee OA. Finally, we estimated QALYs lost specifically due to lower TKR offer and acceptance and higher complications among Black knee OA patients. Black men and women gain 64,100 QALYs from current TKR use. With white offer and complications rates, they would gain an additional 72,000 QALYs. Because these additional gains are unrealized, we call this a loss of 72,000 QALYs. Black Americans lose 67,500 QALYs because of lower offer, 15,800 QALYs because of lower acceptance, and 2,600 QALYs because of higher complications. Black Americans lose 72,000 QALYs due to disparities in TKR offer and complication rates. Programs to decrease disparities in TKR use are urgently needed. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. COST ANALYSIS OF PERIPHERALLY INSERTED CENTRAL CATHETER IN PEDIATRIC PATIENTS.

    Science.gov (United States)

    Dong, Zhaoxin; Connolly, Bairbre L; Ungar, Wendy J; Coyte, Peter C

    2018-01-01

    A peripherally inserted central catheter (PICC) is a useful option in providing secure venous access, which enables patients to be discharged earlier with the provision of home care. The objective was to identify the costs associated with having a PICC from a societal perspective, and to identify factors that are associated with total PICC costs. Data were obtained from a retrospective cohort of 469 hospitalized pediatric patients with PICCs inserted. Both direct and indirect costs were estimated from a societal perspective. Insertion costs, complication costs, nurse and physician assessment costs, inpatient ward costs, catheter removal costs, home care costs, travel costs, and the cost associated with productivity losses incurred by parents were included in this study. Based on catheter dwell time, the median total cost associated with a PICC per patient per day (including inpatient hospital costs) was $3,133.5 ($2,210.7-$9,627.0) in 2017 Canadian dollars ($1.00USD = $1.25CAD in 2017). The adjusted mean cost per patient per day was $2,648.2 ($2,402.4-$2,920.4). Excluding inpatient ward costs, the median total and adjusted costs per patient per day were $198.8 ($91.8-$2,475.8) and $362.7($341.0-$386.0), respectively. Younger age, occurrence of complications, more catheter dwell days, wards with more intensive care, and the absence of home care were significant factors associated with higher total PICC costs. This study has demonstrated the costs associated with PICCs. This information may be helpful for healthcare providers to understand PICC related cost in children and resource implications.

  10. Fermented dairy products consumption is associated with attenuated cortical bone loss independently of total calcium, protein, and energy intakes in healthy postmenopausal women.

    Science.gov (United States)

    Biver, E; Durosier-Izart, C; Merminod, F; Chevalley, T; van Rietbergen, B; Ferrari, S L; Rizzoli, R

    2018-05-03

    A longitudinal analysis of bone microstructure in postmenopausal women of the Geneva Retirees Cohort indicates that age-related cortical bone loss is attenuated at non-bearing bone sites in fermented dairy products consumers, not in milk or ripened cheese consumers, independently of total energy, calcium, or protein intakes. Fermented dairy products (FDP), including yogurts, provide calcium, phosphorus, and proteins together with prebiotics and probiotics, all being potentially beneficial for bone. In this prospective cohort study, we investigated whether FDP, milk, or ripened cheese consumptions influence age-related changes of bone mineral density (BMD) and microstructure. Dietary intakes were assessed at baseline and after 3.0 ± 0.5 years with a food frequency questionnaire in 482 postmenopausal women enrolled in the Geneva Retirees Cohort. Cortical (Ct) and trabecular (Tb) volumetric (v) BMD and microstructure at the distal radius and tibia were assessed by high-resolution peripheral quantitative computerized tomography, in addition to areal (a) BMD and body composition by dual-energy X-ray absorptiometry, at the same time points. At baseline, FDP consumers had lower abdominal fat mass and larger bone size at the radius and tibia. Parathyroid hormone and β-carboxyterminal cross-linked telopeptide of type I collagen levels were inversely correlated with FDP consumption. In the longitudinal analysis, FDP consumption (mean of the two assessments) was associated with attenuated loss of radius total vBMD and of Ct vBMD, area, and thickness. There was no difference in aBMD and at the tibia. These associations were independent of total energy, calcium, or protein intakes. For other dairy products categories, only milk consumption was associated with lower decrease of aBMD and of failure load at the radius. In this prospective cohort of healthy postmenopausal women, age-related Ct bone loss was attenuated at non-bearing bone sites in FDP consumers, not in milk

  11. Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

    Science.gov (United States)

    Gazibegovic, Dzemal; Bero, Eva M

    2017-02-01

    The HiFocus Mid-Scala electrode is intended to improve hearing for individuals with severe-to-profound hearing loss by providing extended electrical coverage of the cochlea while minimizing trauma related to insertion. The electrode is appropriate for use with a wide range of surgical techniques, including either a cochleostomy or round window insertion, and the use of either a free-hand or tool-assisted approach. The objective of this survey was to evaluate how the HiFocus Mid-Scala electrode and insertion tools was used across a population of cochlear implant recipients of differing ages, audiologic profiles, and anatomical characteristics. The intent was to understand the type and frequency of surgical techniques applicable with the electrode, and to provide guidelines for clinical practice. Two questionnaires were completed by surgeons at implant centres located in the United States, Europe, and Asia. Before any surgeries were conducted, surgeons completed a questionnaire that assessed their overall cochlear implant surgical practice and preferences. Following each HiFocus Mid-Scala electrode insertion, surgeons completed a questionnaire that summarized their experience during that surgical procedure. Questionnaires were completed by 32 surgeons from 16 centres for a total of 143 surgeries (112 adults, 31 children). Most surgeons (62 %) preferred to insert the electrode via the round window or an extended round window compared with a cochleostomy (16 %), whereas the remaining 22 % indicated that they made an insertion choice based on presenting anatomy. Sixty-nine percent preferred a free-hand approach over using insertion tools. In 32 procedures, surgeons elected to deviate from an intended round window insertion to either an extended round window or cochleostomy approach.

  12. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  13. Wear Performance of Sequentially Cross-Linked Polyethylene Inserts against Ion-Treated CoCr, TiNbN-Coated CoCr and Al2O3 Ceramic Femoral Heads for Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    Christian Fabry

    2015-02-01

    Full Text Available The aim of the present study was to evaluate the biotribology of current surface modifications on femoral heads in terms of wettability, polyethylene wear and ion-release behavior. Three 36 mm diameter ion-treated CoCr heads and three 36 mm diameter TiNbN-coated CoCr heads were articulated against sequentially cross-linked polyethylene inserts (X3 in a hip joint simulator, according to ISO 14242. Within the scope of the study, the cobalt ion release in the lubricant, as well as contact angles at the bearing surfaces, were investigated and compared to 36 mm alumina ceramic femoral heads over a period of 5 million cycles. The mean volumetric wear rates were 2.15 ± 0.18 mm3·million cycles−1 in articulation against the ion-treated CoCr head, 2.66 ± 0.40 mm3·million cycles−1 for the coupling with the TiNbN-coated heads and 2.17 ± 0.40 mm3·million cycles−1 for the ceramic heads. The TiNbN-coated femoral heads showed a better wettability and a lower ion level in comparison to the ion-treated CoCr heads. Consequently, the low volumes of wear debris, which is comparable to ceramics, and the low concentration of metal ions in the lubrication justifies the use of coated femoral heads.

  14. Global distribution of GPS losses of phase lock and total electron content slips during the 2005 May 15 and the 2003 November 20 magnetic storms

    Science.gov (United States)

    Yasyukevich, Yuriy; Astafeva, Elvira; Givetev, Ilya; Maksikov, Aleksey

    2015-12-01

    Using data of worldwide network of GPS receivers we investigated losses of GPS phase lock (LoL) during two strong magnetic storms. At fundamental L1 frequency, LoL density is found to increase up to 0.25 % and at L2 frequency the increase is up to 3 %. This is several times as much compared with the background level. During the 2003 November 20 magnetic storm, the number of total electron content (TEC) slips exceeded the background level ~50 times. During superstorms, the most number of GPS LoL is observed at low and high latitudes. At the same time, the area of numerous TEC slips correspond to auroral oval boundaries.

  15. Fuel assembly insertion system

    International Nuclear Information System (INIS)

    Barkhurst, D.J.

    1987-01-01

    This patent describes a nuclear reactor facility having fuel bundles: a system for the insertion of a fuel bundle into a position where vertically arranged fuel bundles surround and are adjacent the system comprising, in combination, separate and individual centering devices secured to and disposed on top of each fuel bundle adjacent the position. Each such centering device has a generally box-like cap configuration on the upper end of each fuel bundle and includes: a top wall; first and second side walls, each secured along and upper edge to the top wall; a rear plate attached along opposite vertical edges to the first and second side walls; a front inclined wall joined along an upper edge to the top to the wall and attached along opposite vertical edges first and second side walls; pad means secured to the lower edge of the first and second side walls, the front inclined wall and the rear plate for mounting each centering device on top of an associated fuel bundle; pin means carried by at least two of the pad means engageable with an associated aperature for locating and laterally fixing each centering device on top of its respective fuel bundle. Each front inclined wall of each of the centering devices is orientated on top of its respective fuel bundle to slope upwardly and away from the position where upon downward insertion of a fuel bundle any contact between the lower end of the fuel bundle inserted with a front inclined wall of a centering device will laterally deflect the fuel bundle. Each centering device further includes a central socket means secured to the top wall, and an elongated handling pole pivotally attached to the socket

  16. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  17. Energy loss, range and fluence distributions, total reaction and projectile fragment production cross sections for proton-nucleus and nucleus-nucleus interactions

    International Nuclear Information System (INIS)

    Sihver, L.; Kanai, T.

    1992-07-01

    We have developed a computer code for calculations of energy loss (dE/dx) and range distributions for heavy ions in any media. The results from our calculations are in very good agreement with previous calculations. We have developed semiempirical total reaction cross section formulae for proton-nucleus (with Z p ≤26) and nucleus-nucleus (with Z p and Z t ≤26) reactions. These formulae apply for incident energies above 15 MeV and 100 MeV/nucleon respectively. From the total reaction cross sections, we can calculate the mean free paths and the fluence distributions of protons and heavy ions in any media. We have compared all the calculated reaction cross sections and the mean free paths with experimental data, and the agreement is good. We have also constructed a procedure for calculating projectile fragment production cross sections, by scaling semiempirical proton-nucleus partial cross section systematics. The scaling is performed using a scaling parameter deduced from our reaction cross sections formulae, and additional enhancements factors. All products with atomic number ranging from that of the projectile (Z p ) down to Z=2 can be calculated. The agreement between the calculated cross sections and the experimental data is better than earlier published results. (author)

  18. Angiotensin Converting Enzyme Insertion/Deletion Gene ...

    African Journals Online (AJOL)

    Angiotensin Converting Enzyme Insertion/Deletion Gene Polymorphism: An Observational Study among Diabetic Hypertensive Subjects in Malaysia. ... Methods: The pharmacological effect of ACE inhibition on mean arterial pressure (MAP) and glomerular filtration rate (GFR) were observed among a total of 62 subjects for ...

  19. Effect of zoledronic acid on reducing femoral bone mineral density loss following total hip arthroplasty: A meta-analysis from randomized controlled trails.

    Science.gov (United States)

    Gao, Jian; Gao, Chong; Li, Hui; Wang, Guo-Sheng; Xu, Chang; Ran, Jian

    2017-11-01

    This meta-analysis aimed to assess the efficiency of intravenous administration of zoledronic acid on reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty (THA). A systematic search was performed in Medline (1966-2017.07.31), PubMed (1966-2017.07.31), Embase (1980-2017.07.31), ScienceDirect (1985-2017.07.31) and the Cochrane Library (1966-2017.07.31). Fixed/random effect model was used according to the heterogeneity tested by I 2 statistic. Sensitivity analysis was conducted and publication bias was assessed. Meta-analysis was performed using Stata 11.0 software. Four studies including 185 patients met the inclusion criteria. The present meta-analysis indicated that there were significant differences between groups in terms of periprosthetic bone mineral density in Gruen zone 1 (SMD = 0.752, 95% CI: 0.454 to 1.051, P = 0.000), 2 (SMD = 0.524, 95% CI: 0.230 to 0.819, P = 0.000), 4 (SMD = 0.400, 95% CI: 0.107 to 0.693, P = 0.008), 6 (SMD = 0.893, 95% CI: 0.588 to 1.198, P = 0.000) and 7 (SMD = 0.988, 95% CI: 0.677 to 1.300, P = 0.000). Intravenous administration of zoledronic acid could significantly reduce periprosthetic bone mineral density loss (Gruen zone 1, 2, 4, 6 and 7) after THA. In addition, no severe adverse events were identified. High-quality RCTs with large sample size were still required. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. Test manufacture of the canister insert 135

    International Nuclear Information System (INIS)

    Raiko, H.

    2005-10-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Foundries Jyvaeskylae Oy, in June 2004 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the second trial manufacture of this type of insert in Finland and, in total, the third test manufacture of insert by Metso Foundries Jyvaeskylae Oy. The result fulfilled all the requirements but the material mechanical properties of the cast material. The measured ultimate strength and elongation at rupture were lower than specified in the upper part of the cast. The reason for this was revealed in the metallurgical investigation of the cast material. The cast contained slag (dross). Avoiding the dross formation will be the most demanding challenge of the forthcoming development of the cast procedure. (orig.)

  1. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  2. Role of rs1501299 variant in the adiponectin gene on total adiponectin levels, insulin resistance and weight loss after a Mediterranean hypocaloric diet.

    Science.gov (United States)

    de Luis, Daniel Antonio; Izaola, Olatz; Primo, David; Aller, Rocio

    2017-11-14

    Several adiponectin gene (ADIPOQ) single nucleotide polymorphisms (SNPS) have been related with adiponectin levels and risk for obesity. Our aim was to analyze the effects of rs1501299 ADIPOQ gene polymorphism on total adiponectin levels, insulin resistance and weight loss after a Mediterranean hypocaloric diet in obese subjects. A Caucasian population of 82 obese patients was analyzed, before and after 3 months on a Mediterranean hypocaloric diet. Before and after 3 months on a hypocaloric diet, an anthropometric evaluation, an assessment of nutritional intake and a biochemical analysis were performed. After dietary treatment and in wild type group, weight, BMI, fat mass, leptin levels, systolic blood pressure and waist circumference decreases were similar to the mutant type group. In wild type group, the decrease in total cholesterol was -28.1±15.3 mg/dl (mutant group: -12.6±16.7 mg/dl:p=0.009), LDL- cholesterol was -31.8±20.5 mg/dl (-12.2±11.5 mg/dl:p=0.006), fasting glucose plasma -4.8±2.5 mg/dL (-0.5±0.1 mg/dL:p=0.02), insulin -3.6±1.5 mUI/L (+0.6±1.1 mUI/L:p=0.02) and HOMA-IR -1.2±0.9 (-0.1±1.1:p=0.03). The present study suggests that T allele of ADIPO (rs1501299) could be a predictor of a lack of response of HOMA-IR, insulin, fasting glucose and LDL cholesterol secondary to a Mediterranean hypocaloric diet in obese subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  4. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  5. Micropole undulators: Novel insertion devices for synchrotron sources

    International Nuclear Information System (INIS)

    Toor, A.; Csonka, P.; Tatchyn, R.

    1989-01-01

    Micropole undulators (wigglers) are undulators (wigglers) with submillimeter periods and are referred to, generically, as micropole insertion devices. Compared to ordinary insertion devices, whose period λ u is typically ≥l cm, micropole devices have periods smaller by a factor f≤10. Therefore, the first-harmonic radiation emitted by a micropole undulator will have its photon energy E γ increased by f and its spectral purity Δλ/λ by f, provided the total length of the undulator l u stays unchanged, and magnetic field errors, as well as the electron-beam emittance, are sufficiently small. Furthermore, to generate photons of the same E γ as from the conventional device, the electron-beam energy E e can be reduced by f 1/2 , resulting in significantly lower construction and operating costs. Radiative energy losses can be correspondingly diminished for the associated storage rings. In this paper we report on results recently obtained by us in the practical implementation and design of micropole undulators at the Stanford Synchrotron Radiation Laboratory (SSRL) and the Lawrence Livermore National Laboratory (LLNL). Based on our work, micropole undulators with f≤10 4 appear feasible at the present time

  6. A comparative simulation of feed and bleed operation during the total loss of feedwater event by RELAP5/MOD3 and CEFLASH-4AS/REM computer codes

    International Nuclear Information System (INIS)

    Kwon, Y.M.; Ro, T.S.; Song, J.H.

    1995-01-01

    The Ulchin 3 and 4 nuclear power plants, which are two-loop 2,825 MW(thermal) pressurized water reactors designed by the Korea Atomic Energy Research Institute, adopted a safety depressurization system (SDS) to mitigate the beyond-design-basis event of a total loss of feedwater (TLOFW). A comparative simulation by the CEFLASH-4AS/REM and RELAP5/MOD3 computer codes for the TLOFW event without operator recovery and the TLOFW event with feed and bleed (F and B) operation is performed for Ulchin 3 and 4. In the analyses, the SDS bleed paths are modeled by orifices located on the top of the pressurizer, where the analytical area of the bleed path is based on the Ulchin 3 and 4 SDS design flow capacity. An additional case, where the SDS piping and valves are modeled explicitly, is considered for the RELAP5 analysis. The predictions by the CEFLASH-4AS/REM of the transient two-phase system behavior show good qualitative and quantitative agreement with those by the RELAP5 simulation. The RELAP5 case with explicit piping results in less repressurization and lower reactor coolant system pressure than that of the case without explicit SDS modeling. However, the two cases of RELAP5 analyses result in essentially the same transient scenarios for TLOFW with F and B operation. The results of the simulation demonstrate the validity of the Ulchin 3 and 4 design approach, which employs CEFLASH-4AS/REM computer code and SDS bleed paths modeled by orifices located on the top of the pressurizer. The results also indicate that the decay heat removal and core inventory makeup function can be successfully accomplished by F and B operation by using the SDS for Ulchin 3 and 4

  7. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  8. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  9. Neutron absorber inserts for 55-gal drums

    International Nuclear Information System (INIS)

    Wilson, R.E.; Kim, Y.S.; Toffer, H.

    2000-01-01

    Transport and temporary storage of more than 200 g of fissile material in 55-gal drums at the Rocky Flats Environmental Technology Site (RFETS) have received significant attention during the cleanup mission. This paper discusses successful applications and results of extensive computer studies. Interim storage and movement of fissile material in excess of standard drum limits (200 g) in a safe configuration have been accomplished using special drum inserts. Such inserts have constrained the contents of a drum to two 4-ell bottles. The content of the bottles was limited to 600 g Pu or U in solution or a total of 1200 g for the entire drum. The inserts were a simple design constructed of stainless steel, forming a vertical cylindrical pipe into which two bottles, one on top of the other, could be centered in the drum. The remaining drum volume was configured to preclude any additional bottle placement external to the vertical cylinder. Such inserts in drums were successfully used in moving high-concentration solution from one building to another for chemical processing. Concern about the knowledge of fissile material concentration in bottles prompted another study for drum inserts. The past practice had been to load up to fourteen 4-ell bottles into 55-gal drums, provided the fissile material concentration was < 6 g fissile/ell, and the total drum contents of 200 g fissile was not exceeded. Only one determination of the solution concentration was needed. An extensive safety analysis concluded that a single measurement of bottle content could not ensure compliance with double-contingency-criterion requirements. A second determination of the bottle contents was required before bottles could be placed in a 55-gal drum. Al alternative to a dual-measurement protocol, which is for bolstering administrative control, was to develop an engineered safety feature that would eliminate expensive tests and administrative decisions. A drum insert design was evaluated that would

  10. A phylogenetic analysis of basal metabolism, total evaporative water loss, and life-history among foxes from desert and mesic regions.

    Science.gov (United States)

    Williams, J B; Muñoz-Garcia, A; Ostrowski, S; Tieleman, B I

    2004-01-01

    We measured basal metabolic rate (BMR) and total evaporative water loss (TEWL) of species of foxes that exist on the Arabian Peninsula, Blanford's fox (Vulpes cana) and two subspecies of Red fox (Vulpes vulpes). Combining these data with that on other canids from the literature, we searched for specialization of physiological traits among desert foxes using both conventional least squares regression and regressions based on phylogenetic independent contrasts. Further, we explored the consequences of reduced body size of foxes on life history parameters such as litter size and neonate mass. For Blanford's foxes, Red foxes from the central desert of Arabia, and Red foxes from the more mesic Asir mountains, body mass averaged 1,285 +/- 52 g, 1,967 +/- 289 g, and 3,060 +/- 482 g, respectively, whereas mean BMR, during summer, was 304.5 +/- 32.3 kJ/day, 418.0 +/- 32.4 kJ/day, and 724.1 +/- 120.2 kJ/day (+/- SD). An analysis of covariance with body mass as a covariate showed no statistical differences in BMR among foxes. Analysis of covariance indicated that Red fox from the Asir mountains had a higher TEWL than Red foxes from central Arabia or than Blanford's foxes also from the mountains. Comparisons of all species of desert and mesic foxes showed no significant differences in BMR, nor did desert foxes have a significantly lower BMR than other carnivores. TEWL of desert foxes was lower than other more mesic carnivores; deviations in TEWL ranged from -17.7% for the Fennec fox (Fennecus zerda) to -57.4% for the Kit fox (Vulpes velox). Although desert foxes have a BMR comparable to other more mesic species, it appears that desert foxes do have a smaller body mass, lowering overall energy requirements. We attribute this reduction in body size to the "resource limitation hypothesis" whereby natural selection favors smaller individuals in a resource-limited environment, especially during periods of severe food shortage. However, until common garden experiments are performed

  11. Fiscal 1998 research report on the total electric power loss reduction project for Myanmer; 1998 nendo Myanmer koku denryoku soshitsu sogo teigen project chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    As a part of Japanese clean development mechanism, study was made on reduction of greenhouse effect gas emission from thermal power plants by reduction of power transmission and distribution losses of power systems in Myanmer. Study was made on technical power transmission and distribution losses for the national grid transmission system, 33kV sub- transmission system of Thaketa substation in Yangong city, and 6.6kV and 400V distribution systems of Latha and Lanmadaw townships in the downtown area of Yangong. Countermeasures for power loss reduction were considered on the basis of the study result. The loss reduction project plan includes a construction cost of 5,134,000US$, loss reduction of 7,726kW, and loss reduction of 33,213,000kWh. The project feasibility and profitability were evaluated by comparison between a financial internal rate of return (FIRR) and an opportunity cost assuming that a discount rate is the opportunity cost. As a result, FIRR was 17.36% and the discount rate was 8.89% in Myanmer. (NEDO)

  12. Central Solenoid Insert Technical Specification

    Energy Technology Data Exchange (ETDEWEB)

    Martovetsky, Nicolai N [ORNL; Smirnov, Alexandre [ORNL

    2011-09-01

    The US ITER Project Office (USIPO) is responsible for the ITER central solenoid (CS) contribution to the ITER project. The Central Solenoid Insert (CSI) project will allow ITER validation the appropriate lengths of the conductors to be used in the full-scale CS coils under relevant conditions. The ITER Program plans to build and test a CSI to verify the performance of the CS conductor. The CSI is a one-layer solenoid with an inner diameter of 1.48 m and a height of 4.45 m between electric terminal ends. The coil weight with the terminals is approximately 820 kg without insulation. The major goal of the CSI is to measure the temperature margin of the CS under the ITER direct current (DC) operating conditions, including determining sensitivity to load cycles. Performance of the joints, ramp rate sensitivity, and stability against thermal or electromagnetic disturbances, electrical insulation, losses, and instrumentation are addressed separately and therefore are not major goals in this project. However, losses and joint performance will be tested during the CSI testing campaign. The USIPO will build the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at the Japan Atomic Energy Agency (JAEA), Naka, Japan. The industrial vendors (the Suppliers) will report to the USIPO (the Company). All approvals to proceed will be issued by the Company, which in some cases, as specified in this document, will also require the approval of the ITER Organization. Responsibilities and obligations will be covered by respective contracts between the USIPO, called Company interchangeably, and the industrial Prime Contractors, called Suppliers. Different stages of work may be performed by more than one Prime Contractor, as described in this specification. Technical requirements of the contract between the Company and the Prime Contractor will be covered by the Fabrication Specifications developed by the Prime Contractor based on this document and approved by

  13. Assessment of the ripple effects and spatial heterogeneity of total losses in the capital of China after a great catastrophic shock

    Directory of Open Access Journals (Sweden)

    Z. Zhang

    2017-03-01

    introduce the sectors' losses caused by the 2008 Wenchuan earthquake (2008 WCE in Beijing, utilizing the Adaptive Regional Input–Output (ARIO model and the Inter-regional ripple effect (IRRE model. The purpose is to assess the ripple effects of indirect economic loss and spatial heterogeneity of both direct and indirect economic loss at the scale of the smallest administrative divisions of China (streets, villages, and towns. The results indicate that the district of Beijing with the most severe indirect economic loss is the Chaoyang District; the finance and insurance industry (15, see Table 1 of Chaowai Street suffers the most in the Chaoyang District, which is 1.46 times that of its direct economic loss. During 2008–2014, the average annual GDP (gross domestic product growth rate of Beijing was decreased 3.63 % by the catastrophe. Compared with the 8 % of GDP growth rate target, the decreasing GDP growth rate is a significant and noticeable economic impact, and it can be efficiently mitigated by increasing rescue effort and by supporting the industries which are located in the seriously damaged regions.

  14. Wear debris. An environmental issue in total joint replacement.

    Science.gov (United States)

    Manley, M T; Serekian, P

    1994-01-01

    There is a growing concern that osteolytic lesions, often adjacent to otherwise stable implants, are a recent phenomenon caused by some recent change in polyethylene, metal, or other aspect of the total hip construction. This study investigates the possibility that bearings and modular connections used in modern hip replacements are an unappreciated source of particulate debris. Measurements taken from contemporary femoral bearings show a significant mismatch in both surface finish and sphericity of mating metal and polyethylene components, with sphericity of inserts being much worse then sphericity of femoral heads. The tolerances for sphericity of polyethylene inserts were further changed by the placement of an insert into its metal shell. Hip simulator tests of assembled inserts and shells showed greater polyethylene weight loss for metal-backed shells than for inserts alone. Bending and torsional tests of metal/metal modular connections showed that dynamic loads can release large numbers of debris particles from taper junctions. Because osteolytic lesions clearly are associated with overload of tissue by debris particles, the design, manufacture, and tolerances of modular connections in total hip replacement all seem to require reevaluation.

  15. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  16. Body composition during weight loss in obese patients estimated by dual energy X-ray absorptiometry and by total body potassium

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Andersen, T

    1996-01-01

    for FFM were strong (r = 0.92 and 0.93). Bland and Altman plots showed limits of agreement of +/-9 kg before and after weight loss; DXA underestimated FFM in women and overestimated FFM in men. DXA accounted for 80% of the lost body weight. The composition of the lost body mass did not differ from...... that estimated by TBK (7.6% FFM and 92.4% FM by TBK; 11% FFM and 89% FM by DXA). CONCLUSION: DXA estimates accurately the body composition and the composition of weight loss in groups of obese subjects. However, the scan table may be too small for patients weighing more than 95 kg....

  17. Quenching Mo optical losses in CIGS solar cells by a point contacted dual-layer dielectric spacer: a 3-D optical study

    NARCIS (Netherlands)

    Rezaei, N.; Isabella, O.; Vroon, Z.; Zeman, M.

    2018-01-01

    A 3-D optical modelling was calibrated to calculate the light absorption and the total reflection of fabricated CIGS solar cells. Absorption losses at molybdenum (Mo) / CIGS interface were explained in terms of plasmonic waves. To quench these losses, we assumed the insertion of a lossless

  18. Quenching Mo optical losses in CIGS solar cells by a point contacted dual-layer dielectric spacer : A 3-D optical study

    NARCIS (Netherlands)

    Rezaei, N.; Isabella, O.; Vroon, Zeger; Zeman, M.

    2018-01-01

    A 3-D optical modelling was calibrated to calculate the light absorption and the total reflection of fabricated CIGS solar cells. Absorption losses at molybdenum (Mo) / CIGS interface were explained in terms of plasmonic waves. To quench these losses, we assumed the insertion of a lossless

  19. Updated of the events tree of total loss of power at the site, SBO, taking into account the results of stress tests and methodological updates, convolution, and hydraulic power recovery from model RCPs

    International Nuclear Information System (INIS)

    Lopez Lorenzo, M. A.; Perez Martin, F.

    2013-01-01

    In this paper, is described a tree of events to an accident loss total power at the site (SBO) considering, first the results of stress tests arising from the Fukushima accident and moreover, various methodological updates related to this initiating event.

  20. Nutritional management after total laryngectomy

    African Journals Online (AJOL)

    28 September 2010 with a known diagnosis of cancer of the larynx. The patient, who underwent a total laryngectomy on 13 October, had a tracheostomy inserted .... status, leading to improved quality of life and better response to treatment.4.

  1. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    ). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R......) was also insignificant. Three BIA equations from the literature, which were not specific for the degree of obesity in the present study group, predicted changes in FFM (from 0.5 + 3.6 to 2.4 +/- 4.4kg, p > 0.05) that were comparable with those estimated by the reference methods. Eight equations from...

  2. The Presenilin-1 ΔE9 Mutation Results in Reduced γ-Secretase Activity, but Not Total Loss of PS1 Function, in Isogenic Human Stem Cells

    Directory of Open Access Journals (Sweden)

    Grace Woodruff

    2013-11-01

    Full Text Available Presenilin 1 (PS1 is the catalytic core of γ-secretase, which cleaves type 1 transmembrane proteins, including the amyloid precursor protein (APP. PS1 also has γ-secretase-independent functions, and dominant PS1 missense mutations are the most common cause of familial Alzheimer’s disease (FAD. Whether PS1 FAD mutations are gain- or loss-of-function remains controversial, primarily because most studies have relied on overexpression in mouse and/or nonneuronal systems. We used isogenic euploid human induced pluripotent stem cell lines to generate and study an allelic series of PS1 mutations, including heterozygous null mutations and homozygous and heterozygous FAD PS1 mutations. Rigorous analysis of this allelic series in differentiated, purified neurons allowed us to resolve this controversy and to conclude that FAD PS1 mutations, expressed at normal levels in the appropriate cell type, impair γ-secretase activity but do not disrupt γ-secretase-independent functions of PS1. Thus, FAD PS1 mutations do not act as simple loss of PS1 function but instead dominantly gain an activity toxic to some, but not all, PS1 functions.

  3. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    An ISABELLE workshop of the summer 1976 series, which was held at Brookhaven August 16--20, focused on the design and utilization of the experimental insertions. The goals of the workshop are outlined, and a few general remarks about the results are presented

  4. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  5. DRYING TEMPERATURE EFFECT OF GRANULE CONTAINING OIL COMBINATION OF LEMONGRASS-KAFFIR LIME LEAVES ON TOTAL LOSS OF OIL AND LARVICIDE ACTIVITIES

    Directory of Open Access Journals (Sweden)

    Sri Mulyani

    2016-04-01

    Full Text Available Granules of lemongrass and kaffir lime oil are reported to have larvicidal activity against the mosquito Aedes aegypti, with LC50 of 38.30ppm and 39.58ppm, while LC90 of 51.57ppm and 79.43ppm respectively. During the manufacture of granules, loss of oil are reported by 64.20% to 65.91% for lemongrass and kaffir lime oil. This research aims to make granules combination from lemongrass and kaffir lime oils by varying the temperature of the drying granules and testing its larvicidal activity against Ae. aegypti. Oil combination is selected by using analysis simplex lattice design, and the combination chosen is made of granules, in drying room temperature for 24h, a temperature of 50°C for 2h 30min and a temperature of 70°C for 1h. Larvicidal activity testing against larvae of Ae. aegypti is done by using the third instar larvae 20 for each granule solution made in 5 series of concentration, and left exposed for 24h. The number of deaths of larvae is calculated and analyzed by modified probit analysis Finney to determine LC50 and LC90. The results showed the combination lemongrass-kaffir lime oil is selected ratio of 9:1, and drying the granules with a temperature of 70°C for 1h produces the greatest larvicidal activity with 63.17ppm LC50 and LC90 of 85.04ppm.

  6. Fragmentation of Rapid Eye Movement and Nonrapid Eye Movement Sleep without Total Sleep Loss Impairs Hippocampus-Dependent Fear Memory Consolidation.

    Science.gov (United States)

    Lee, Michael L; Katsuyama, Ângela M; Duge, Leanne S; Sriram, Chaitra; Krushelnytskyy, Mykhaylo; Kim, Jeansok J; de la Iglesia, Horacio O

    2016-11-01

    Sleep is important for consolidation of hippocampus-dependent memories. It is hypothesized that the temporal sequence of nonrapid eye movement (NREM) sleep and rapid eye movement (REM) sleep is critical for the weakening of nonadaptive memories and the subsequent transfer of memories temporarily stored in the hippocampus to more permanent memories in the neocortex. A great body of evidence supporting this hypothesis relies on behavioral, pharmacological, neural, and/or genetic manipulations that induce sleep deprivation or stage-specific sleep deprivation. We exploit an experimental model of circadian desynchrony in which intact animals are not deprived of any sleep stage but show fragmentation of REM and NREM sleep within nonfragmented sleep bouts. We test the hypothesis that the shortening of NREM and REM sleep durations post-training will impair memory consolidation irrespective of total sleep duration. When circadian-desynchronized animals are trained in a hippocampus-dependent contextual fear-conditioning task they show normal short-term memory but impaired long-term memory consolidation. This impairment in memory consolidation is positively associated with the post-training fragmentation of REM and NREM sleep but is not significantly associated with the fragmentation of total sleep or the total amount of delta activity. We also show that the sleep stage fragmentation resulting from circadian desynchrony has no effect on hippocampus-dependent spatial memory and no effect on hippocampus-independent cued fear-conditioning memory. Our findings in an intact animal model, in which sleep deprivation is not a confounding factor, support the hypothesis that the stereotypic sequence and duration of sleep stages play a specific role in long-term hippocampus-dependent fear memory consolidation. © 2016 Associated Professional Sleep Societies, LLC.

  7. Does a thrombin-based topical haemostatic agent reduce blood loss and transfusion requirements after total knee revision surgery? A randomized, controlled trial.

    Science.gov (United States)

    Romanò, Carlo L; Monti, Lorenzo; Logoluso, Nicola; Romanò, Delia; Drago, Lorenzo

    2015-11-01

    The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. II.

  8. The first LHC insertion quadrupole

    CERN Multimedia

    2004-01-01

    An important milestone was reached in December 2003 at the CERN Magnet Assembly Facility. The team from the Accelerator Technology - Magnet and Electrical Systems group, AT-MEL, completed the first special superconducting quadrupole for the LHC insertions which house the experiments and major collider systems. The magnet is 8 metres long and contains two matching quadrupole magnets and an orbit corrector, a dipole magnet, used to correct errors in quadrupole alignment. All were tested in liquid helium and reached the ultimate performance criteria required for the LHC. After insertion in the cryostat, the superconducting magnet will be installed as the Q9 quadrupole in sector 7-8, the first sector of the LHC to be put in place in 2004. Members of the quadrupole team, from the AT-MEL group, gathered around the Q9 quadrupole at its inauguration on 12 December 2003 in building 181.

  9. Insertion device calculations with mathematica

    Energy Technology Data Exchange (ETDEWEB)

    Carr, R. [Stanford Synchrotron Radiation Lab., CA (United States); Lidia, S. [Univ. of California, Davis, CA (United States)

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectory solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.

  10. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  11. Vacuum guidelines for ISA insertions

    International Nuclear Information System (INIS)

    Edwards, D. Jr.

    1976-01-01

    Vacuum requirements place design restrictions on the ISA insertions. The vacuum tube diameter, given a distance L between pumps, is determined by the desorption of molecules from the wall under the impact of ions created by the beam, whereas the thickness of the tube must be sufficient to prevent collapse. In addition, the entire vacuum chamber must be able to be baked out at approximately 200 0 C

  12. Inserts for nuclear fuel elements

    International Nuclear Information System (INIS)

    Cragg, P.J.

    1982-01-01

    An insert for a nuclear fuel pin which comprises a strip. The strip carries notches, which enable a coding arrangement to be carried on the strip. The notches may be of differing sizes and the coding on the strip includes identification and identification checking data. Each notch on the strip may give rise to a signal pulse which is counted by a detector to avoid errors. (author)

  13. ATLAS insertable B-layer

    Czech Academy of Sciences Publication Activity Database

    Marčišovský, Michal

    2011-01-01

    Roč. 633, č. 1 (2011), "S224"-"S225" ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA MŠk LA08015; GA MŠk LA08032 Institutional research plan: CEZ:AV0Z10100502 Keywords : ATLAS * pixel detector * insertable B-layer Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.207, year: 2011

  14. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb$_{3}$Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb$_{3}$Sn m...

  15. A New Scientific use of Total Eclipses of the Moon: Studies of the Generation and Loss of Atmospheres of Primitives Bodies

    Science.gov (United States)

    Mendillo, Michael

    1999-01-01

    This grant supported observational campaigns to record the size and brightness of the lunar atmosphere as seen in sodium gas (Na) emissions during the totality phase of lunar eclipses. Three eclipse events were attempted, two from the Mc Donald Observatory in Fort Davis Texas, and one from the site of Italy's Galileo National Telescope (GNT) in La Palma, in the Canary Islands. In all three cases, clear skies prevailed and excellent datasets were obtained. Following the observational component of the grant, a period of detailed processing and analysis began. Eclipse events were chosen for study because when the moon is in full phase it has been within the terrestrial magnetosphere for a few days, thereby shielded from solar wind impact upon its surface. Since sputtering of Na from the lunar regolith by solar wind particles had been proposed as a source of the Moon's atmosphere, this was a test of the mechanism. If the lunar Na appeared to be diminished in comparison to abundances seen at other phases (e.g., at quarter phase when the moon is directly in the solar wind), the solar wind sputtering would indeed be a major source of lunar Na. These experiments could not be conducted during any full moon night because scattering of bright moonlight is so strong that low-light-level imaging of the lunar atmosphere could not be achieved. Hence, the use of eclipses. The final result of these experiments was, for once, clear and unambiguous. The robust size and Na brightness levels measured during all of the eclipses showed that solar wind sputtering could not be a major source of the lunar atmosphere. A major paper on this conclusion was published in ICARUS, and an oral presentation of partial results given at the The Three Galileos conference in Padova (Italy) in January 1997 and at the DPS meeting in Cambridge, MA, in July 1997.

  16. Clinical outcome of narrow diameter implants inserted into allografts

    Directory of Open Access Journals (Sweden)

    Maurizio Franco

    2009-08-01

    Full Text Available OBJECTIVE: Narrow diameter implants (NDI (i.e. diameter <3.75 mm are a potential solution for specific clinical situations, such as reduced interradicular bone, thin alveolar crest and replacement of teeth with small cervical diameter. NDI have been available in clinical practice since the 1990s, but only few studies have analyzed their clinical outcome and no study have investigated NDI inserted in fresh-frozen bone (FFB grafts. Thus, a retrospective study on a series of NDI placed in homologue FFB was designed to evaluate their clinical outcome. MATERIAL AND METHODS: In the period between December 2003 and December 2006, 36 patients (22 females and 14 males, mean age 53 years with FFB grafts were selected and 94 different NDI were inserted. The mean follow-up was 25 months. To evaluate the effect of several host-, surgery-, and implant-related factors, marginal bone loss (MBL was considered an indicator of success rate (SCR. The Kaplan Meier algorithm and Cox regression were used. RESULTS: Only 5 out of 94 implants were lost (i.e. survival rate - SVR 95.7% and no differences were detected among the studied variables. On the contrary, the Cox regression showed that the graft site (i.e. maxilla reduced MBL. CONCLUSIONS: NDI inserted in FFB have a high SVR and SCR similar to those reported in previous studies on regular and NDI inserted in non-grafted jaws. Homologue FFB is a valuable material in the insertion of NDI.

  17. Field errors in hybrid insertion devices

    International Nuclear Information System (INIS)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed

  18. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  19. Regional insertion: an emergent approach

    International Nuclear Information System (INIS)

    Serra, M.T.F.; Nascimento Teixeira, P. do

    1989-01-01

    The Brazilian Electrical Sector incorporates new variables that expressing the extensive spectrum of environmental impacts in the take of decisions, referring to the viability of realizing a electrical undertaking, attends the several restrictions that are important by the sector and by the society in the environment area and promotes the adequate generation of liquid benefits, consequential of the electrical undertaking. Due to these factors, the Electrical Sector is improving the concept of regional insertion, with the sectorial expansion in long-dated and the created demand in the environmental and social area, focalizing the solution for these questions. (C.G.C.). 1 fig, 2 tabs

  20. Recent advances in insertion devices

    International Nuclear Information System (INIS)

    Gluskin, E.; Moog, E.R.

    1995-01-01

    Demand for more and better insertion devices (IDs) at new third-generation synchrotron radiation facilities has led to significant advances in ID technology at different laboratories around the world. In this overview of this progress, focus is on those results that apply to IDs in general rather than one specific ID or laboratory. The advances fall into two general categories: those that reduce the net effect that the ID has on the particle beam, and those that enhance the quality of the emitted light spectrum. The need for these advances, factors that are most important inaachieving them, and the current state of the art are discussed

  1. Summary of experimental insertions workshop

    International Nuclear Information System (INIS)

    Sandweiss, J.; Month, M.

    1976-01-01

    The last ISABELLE workshop of the summer 1976 series, which was held at Brookhaven, August 16-20, focused on the design and utilization of the experimental insertions. The goals of the workshop, which were somewhat more general than might be suggested by the title, are: (1) review the ISABELLE proposal from the point of view of experimental use; (2) contribute useful information on the ''open questions'' in the ISABELLE design; (3) develop data for experimental equipment and operating cost estimates; and (4) project a first approximation to ISABELLE operating modes

  2. Regulatory perspective on incomplete control rod insertions

    International Nuclear Information System (INIS)

    Chatterton, M.

    1997-01-01

    The incomplete control rod insertions experienced at South Texas Unit 1 and Wolf Creek are of safety concern to the NRC staff because they represent potential precursors to loss of shutdown margin. Even before it was determined if these events were caused by the control rods or by the fuel there was an apparent correlation of the problem with high burnup fuel. It was determined that there was also a correlation between high burnup and high drag forces as well as with rod drop time histories and lack of rod recoil. The NRC staff initial actions were aimed at getting a perspective on the magnitude of the problem as far as the number of plants and the amount of fuel that could be involved, as well as the safety significance in terms of shutdown margin. As tests have been performed and data has been analyzed the focus has shifted more toward understanding the problem and the ways to eliminate it. At this time the staff's understanding of the phenomena is that it was a combination of factors including burnup, power history and temperature. The problem appears to be very sensitive to these factors, the interaction of which is not clearly understood. The model developed by Westinghouse provides a possible explanation but there is not sufficient data to establish confidence levels and sensitivity studies involving the key parameters have not been done. While several fixes to the problem have been discussed, no definitive fixes have been proposed. Without complete understanding of the phenomena, or fixes that clearly eliminate the problem the safety concern remains. The safety significance depends on the amount of shutdown margin lost due to incomplete insertion of the control rods. Were the control rods to stick high in the core, the reactor could not be shutdown by the control rods and other means such as emergency boration would be required

  3. Insertion and crossing region design

    International Nuclear Information System (INIS)

    Wienands, U.; Beloshitsky, P.

    2001-01-01

    This article is the summary of the 5-afternoon tutorial on insertions for circular machines. Roughly half the course (Part 1) was spent discussing interaction regions, We start by recapitulating basic beam optics including building blocks. This provides the tools to analyze the basic structure of interaction regions and explore the parameter space. This simple example is then successively refined and made more realistic. Examples of realized interaction regions for both hadron and electron machines are shown and their salient features and differences explained. A brief discussion of solenoid-decoupling brings Part 1 to a close. In Part 2 we discussed various utility sections. Dispersion suppressors are presented in detail discussing the principles as well as the practical implementation of flexible suppressors using LEP as an example. Injection schemes, both single-turn and multi-turn stacking, are presented in depth. The matching of wiggler and undulator insertions and a discussion of the impact of these devices on beam parameters closes out Part 2

  4. Remifentanil dose for laryngeal mask airway insertion with a single standard dose of propofol during emergency airway management in elderly patients.

    Science.gov (United States)

    Ryu, Junghee; Oh, Ah Young; Baek, Ji-Seok; Kim, Jin-Hee; Park, Sang-Heon; Noh, Jae-Mun

    2014-04-01

    This study determined the dose of remifentanil to use during insertion of a Classic™ laryngeal mask airway (LMA, The Laryngeal Mask Co., Nicosia, Cyprus) in elderly patients during emergency airway management when combined with a single dose of propofol. Patients aged 65-80 years were enrolled. Anesthesia was induced with propofol 1 mg/kg, and then a blinded dose of remifentanil was infused over 30 s after confirming the patient's loss of consciousness. The dose of remifentanil was determined using Dixon's up-and-down method, starting at 0.5 µg/kg (a step size of 0.1 µg/kg). Insertion of the LMA was attempted 60 s after loss of consciousness. In total, 23 patients were recruited and the mean age ± standard deviation was 72 ± 3 years. The effective dose for successful LMA insertion in 50% of the patients (ED50) was 0.20 ± 0.05 µg/kg. No patient needed more than 0.3 µg/kg. Remifentanil 0.20 ± 0.05 µg/kg with propofol 1 mg/kg resulted in excellent LMA insertion in 50% of elderly patients without significant hemodynamic changes during emergency airway management.

  5. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  6. Acute effect of weight loss on levels of total bilirubin in obese, cardiovascular high-risk patients: an analysis from the lead-in period of the Sibutramine Cardiovascular Outcome trial

    DEFF Research Database (Denmark)

    Andersson, Charlotte; Weeke, Peter; Fosbøl, Emil Loldrup

    2009-01-01

    Low levels of bilirubin are associated with an increased risk of cardiovascular adverse events. Weight reduction is known to reduce several cardiovascular risk factors, but effects on bilirubin levels have not been reported. We studied the response of weight loss therapy with sibutramine and life......Low levels of bilirubin are associated with an increased risk of cardiovascular adverse events. Weight reduction is known to reduce several cardiovascular risk factors, but effects on bilirubin levels have not been reported. We studied the response of weight loss therapy with sibutramine...... and lifestyle change on levels of total bilirubin in an overweight or obese, cardiovascular high-risk population. Data from the first 4 weeks of the lead-in period of the Sibutramine Cardiovascular Outcome study were analyzed. A total of 10 198 patients provided body weight measurements before and after 4 weeks...... of sibutramine treatment (10 mg daily), of whom 1059 (10.4%) gained weight, 1467 (13.7%) lost greater than 0% to 1%, 2492 (23.2%) lost greater than 1% to 2%, 2280 (21.2%) lost greater than 2% to 3%, 1498 (13.9%) lost greater than 3% to 4%, and 1402 (13.1%) lost greater than 4% of their initial weight...

  7. The optimal protocol to reduce blood loss and blood transfusion after unilateral total knee replacement: Low-dose IA-TXA plus 30-min drain clamping versus drainage clamping for the first 3 h without IA-TXA.

    Science.gov (United States)

    Park, Joo Hyun; Choi, Sung Wook; Shin, Eun Ho; Park, Myung Hoon; Kim, Myung Ku

    2017-01-01

    Although intraarticular tranexamic acid (IA-TXA) administration or drainage clamping are popular methods used to reduce blood loss after total knee replacement (TKR), the protocol remains controversial. We aimed (1) to establish new protocols through investigating whether two methods, that is, low-dose (500 mg) IA-TXA plus 30-min drain clamping and drainage clamping for the first 3 h without IA-TXA, can reduce blood loss and blood transfusion after unilateral TKR and (2) to make recommendations related to clinical application. This study, conducted from September 2014 to June 2016 related to enrolled 95 patients with primary osteoarthritis who were to have a unilateral cemented TKR, was nonrandomized and retrospective. In group A, the drain was released following tourniquet deflation. In group B, 500-mg TXA was injected into the knee joint via a drain tube after fascia closure and the drain was clamped for the first 30 min to prevent leakage. In group C, the drain was clamped for the first 3-h postoperation. Demographic characteristics and clinical data were collected, including the levels of hematocrit (Hct), the total blood loss (TBL), drained blood volume (BV), the amount of blood transfused, and any complications that developed. We found a significantly lower postoperative TBL, drained BV, decreasing Hct level, and less transfused BV in the IA-TXA injection group (group B) and the 3-h drainage clamping group (group C) compared to the conventional negative drainage group (group A; p optimal than drainage clamping in patients with high bleeding tendency or lateral retinacular release during TKR, who would be concerned about postoperative wound complication.

  8. Collimator Layouts for HL-LHC in the Experimental Insertions

    CERN Document Server

    Bruce, R; Esposito, Luigi Salvatore; Jowett, John; Lechner, Anton; Quaranta, Elena; Redaelli, Stefano; Schaumann, Michaela; Skordis, Eleftherios; Eleanor Steele, G; Garcia Morales, H; Kwee-Hinzmann, Regina

    2015-01-01

    This paper presents the layout of collimators for HL-LHC in the experimental insertions. On the incoming beam, we propose to install additional tertiary collimators to protect potential new aperture bottlenecks in cells 4 and 5, which in addition reduce the experimental background. For the outgoing beam, the layout of the present LHC with three physics debris absorbers gives sufficient protection for highluminosity proton operation. However, collisional processes for heavy ions cause localized beam losses with the potential to quench magnets. To alleviate these losses, an installation of dispersion suppressor collimators is proposed.

  9. Swirl flow analysis in a helical wire inserted tube using CFD code

    International Nuclear Information System (INIS)

    Park, Yusun; Chang, Soon Heung

    2010-01-01

    An analysis on the two-phase flow in a helical wire inserted tube using commercial CFD code, CFX11.0, was performed in bubbly flow and annular flow regions. The analysis method was validated with the experimental results of Takeshima. Bubbly and annular flows in a 10 mm inner diameter tube with varying pitch lengths and inserted wire diameters were simulated using the same analysis methods after validation. The geometry range of p/D was 1-4 and e/D was 0.08-0.12. The results show that the inserted wire with a larger diameter increased swirl flow generation. An increasing swirl flow was seen as the pitch length increased. Regarding pressure loss, smaller pitch lengths and inserted wires with larger diameters resulted in larger pressure loss. The average liquid film thickness increased as the pitch length and the diameter of the inserted wire increased in the annular flow region. Both in the bubbly flow and annular flow regions, the effect of pitch length on swirl flow generation and pressure loss was more significant than that of the inserted wire diameters. Pitch length is a more dominant factor than inserted wire diameter for the design of the swirl flow generator in small diameter tubes.

  10. Estimating Rates of Fault Insertion and Test Effectiveness in Software Systems

    Science.gov (United States)

    Nikora, A.; Munson, J.

    1998-01-01

    In developing a software system, we would like to estimate the total number of faults inserted into a software system, the residual fault content of that system at any given time, and the efficacy of the testing activity in executing the code containing the newly inserted faults.

  11. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  12. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  13. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  14. Insertion material for controlling reactivity

    International Nuclear Information System (INIS)

    Baba, Iwao.

    1994-01-01

    Moderators and a group of suspended materials having substantially the same density as the moderator are sealed in a hollow rod vertically inserted to a fuel assembly. Specifically, the group of suspended materials is adapted to have a density changing stepwise from density of the moderator at the exit temperature of the reactor core to that at the inlet temperature of the reactor core. Reactivity is selectively controlled for a portion of high power and a portion of high reactivity by utilizing the density of the moderator and the distribution of the density. That is, if the power distribution is flat, the density of the moderators changes at a constant rate over the vertical direction of the reactor core and the suspended materials stay at a portion of the same density, to form a uniform distribution. Further, upon reactor shutdown, since the liquid temperature of the moderators is lowered and the density is increased, all of beads are collected at the upper portion to remove water at the upper portion of the reactor core of low burnup degree thereby selectively controlling the reactivity at a portion of high power and a portion of high reactivity. (N.H.)

  15. Factors related to persisting perforations after ventilation tube insertion.

    Science.gov (United States)

    O'Connell Ferster, Ashley P; Tanner, April Michelle; Karikari, Kodjo; Roberts, Christopher; Wiltz, Derek; Carr, Michele M

    2016-02-01

    Over a million ventilation tubes are placed annually in the United States, making this one of the most commonly performed procedures in the field of medicine. Certain factors increase the risk of persistent tympanic membrane perforation following the extrusion of short term ventilation tubes. Persistent perforations may fail to heal on their own, necessitating surgical closure to avoid conductive hearing loss. It is important to detect factors that may predict children who are at increased risk for persistent perforations. This study was a retrospective chart review that involved 757 patients between 2003 and 2008. The patients studied were within the age of 2 months-17 years, and all had short term tubes placed. The chart data also included demographic information, comorbidities, and information related to tube insertion and follow-up care. Chi-square, t-test, and multivariate logistic regression were conducted to compare variables between patients with perforations and those without. Data from 757 patients was analyzed, showing that perforation rate is associated with rhinorrhea, operative tube removal, aural polyps, and otorrhea (OR 1.72, 8.16, 4.69, and 1.72 respectively). The absence of otorrhea decreased the likelihood of TM perforations and no significant differences were found in gender, total number of sets of tubes, type of tube, use of nasal steroids, adenoidectomy, or nasal congestion. Our findings suggest that children with rhinorrhea, otorrhea, aural polyps, or prolonged intubation requiring operative tube removal should be identified clinically as children at risk of persisting perforation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. Hearing loss

    Science.gov (United States)

    Decreased hearing; Deafness; Loss of hearing; Conductive hearing loss; Sensorineural hearing loss; Presbycusis ... Symptoms of hearing loss may include: Certain sounds seeming too loud Difficulty following conversations when two or more people are talking ...

  17. Bedside prediction of right subclavian venous catheter insertion length

    Directory of Open Access Journals (Sweden)

    Yoon Ji Choi

    2014-12-01

    Full Text Available Background and objective: The present study aimed to evaluate whether right subclavian vein (SCV catheter insertion depth can be predicted reliably by the distances from the SCV insertion site to the ipsilateral clavicular notch directly (denoted as I-IC, via the top of the SCV arch, or via the clavicle (denoted as I-T-IC and I-C-IC, respectively. Method: In total, 70 SCV catheterizations were studied. The I-IC, I-T-IC, and I-C-IC distances in each case were measured after ultrasound-guided SCV catheter insertion. The actual length of the catheter between the insertion site and the ipsilateral clavicular notch, denoted as L, was calculated by using chest X-ray. Results: L differed from the I-T-IC, I-C-IC, and I-IC distances by 0.14±0.53, 2.19±1.17, and -0.45 ±0.68 cm, respectively. The mean I-T-IC distance was the most similar to the mean L (intraclass correlation coefficient = 0.89. The mean I-IC was significantly shorter than L, while the mean I-C-IC was significantly longer. Linear regression analysis provided the following formula: Predicted SCV catheter insertion length (cm = -0.037 + 0.036 × Height (cm + 0.903 × I-T-IC (cm (adjusted r2 =0.64. Conclusion: The I-T-IC distance may be a reliable bedside predictor of the optimal insertion length for a right SCV cannulation.

  18. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  19. Clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy insertion.

    Science.gov (United States)

    Stewart, Jessica K; Smith, Tony P; Kim, Charles Y

    To determine the clinical implications of acute pelvicaliceal hematoma formation during percutaneous catheter nephrostomy (PCN) insertion. Collecting system hematoma burden was retrospectively assessed for 694 PCN insertions in 502 patients. Pelvicaliceal hematoma formation occurred in 146 kidneys (21%) in 136 patients. Clinically significant blood loss occurred in 3 patients with hematomas within one week compared to 4 patients without hematomas (p=0.39). Twenty-four patients with hematomas underwent catheter exchange within one week, compared to 55 patients without hematomas (p=0.49). Pelvicaliceal hematoma formation after PCN insertion is not uncommon and is associated with very rare clinical sequelae. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre

    OpenAIRE

    Roopal, Dr.; Bisht, Vandana

    2018-01-01

    Background: A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre.Methods: This prospective study was conducted among 100 women at tertiary care centre, Haldwani, Nainital. Patients were divided in to two groups. Group A (n=50)-post placental insertion within 10 minutes of delivery of placenta. Group B (n=50)-Interval insertion after 6 weeks of delivery. Both groups were compared in terms of pain abdomen, bleeding, missing thread, expulsion,...

  1. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  2. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  3. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  4. Laparoscopic insertion of the Moss feeding tube.

    Science.gov (United States)

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  5. Pregnancy Loss

    Science.gov (United States)

    ... To receive Pregnancy email updates Enter email Submit Pregnancy loss Pregnancy loss is a harsh reality faced ... have successful pregnancies. Expand all | Collapse all Why pregnancy loss happens As many as 10 to 15 ...

  6. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  7. Rescuing Alu: recovery of new inserts shows LINE-1 preserves Alu activity through A-tail expansion.

    Directory of Open Access Journals (Sweden)

    Bradley J Wagstaff

    Full Text Available Alu elements are trans-mobilized by the autonomous non-LTR retroelement, LINE-1 (L1. Alu-induced insertion mutagenesis contributes to about 0.1% human genetic disease and is responsible for the majority of the documented instances of human retroelement insertion-induced disease. Here we introduce a SINE recovery method that provides a complementary approach for comprehensive analysis of the impact and biological mechanisms of Alu retrotransposition. Using this approach, we recovered 226 de novo tagged Alu inserts in HeLa cells. Our analysis reveals that in human cells marked Alu inserts driven by either exogenously supplied full length L1 or ORF2 protein are indistinguishable. Four percent of de novo Alu inserts were associated with genomic deletions and rearrangements and lacked the hallmarks of retrotransposition. In contrast to L1 inserts, 5' truncations of Alu inserts are rare, as most of the recovered inserts (96.5% are full length. De novo Alus show a random pattern of insertion across chromosomes, but further characterization revealed an Alu insertion bias exists favoring insertion near other SINEs, highly conserved elements, with almost 60% landing within genes. De novo Alu inserts show no evidence of RNA editing. Priming for reverse transcription rarely occurred within the first 20 bp (most 5' of the A-tail. The A-tails of recovered inserts show significant expansion, with many at least doubling in length. Sequence manipulation of the construct led to the demonstration that the A-tail expansion likely occurs during insertion due to slippage by the L1 ORF2 protein. We postulate that the A-tail expansion directly impacts Alu evolution by reintroducing new active source elements to counteract the natural loss of active Alus and minimizing Alu extinction.

  8. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  9. Utility Bill Insert for Wastewater Services

    Science.gov (United States)

    Intended for use by wastewater and water supply utilities, one side of the utility bill insert has information for customers that discharge to sanitary sewer systems; the other side is for customers with septic systems.

  10. HB+ inserted into the CMS Solenoid

    CERN Multimedia

    Tejinder S. Virdee, CERN

    2006-01-01

    The first half of the barrel hadron calorimeter (HB+) has been inserted into the superconducting solenoid of CMS, in preparation for the magnet test and cosmic challenge. The operation went smoothly, lasting a couple of days.

  11. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  12. Updated of the events tree of total loss of power at the site, SBO, taking into account the results of stress tests and methodological updates, convolution, and hydraulic power recovery from model RCPs; Actualizacion del arbol de sucesos de perdida total de suministro electro en el emplazamiento, SBO, teniendo en cuenta los resultados de los estres tests y actualizaciones metodologicas, convolucion, recuperacion desde centrales hidraulicas y modelo de sellos de las RCPs

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Lorenzo, M. A.; Perez Martin, F.

    2013-07-01

    In this paper, is described a tree of events to an accident loss total power at the site (SBO) considering, first the results of stress tests arising from the Fukushima accident and moreover, various methodological updates related to this initiating event.

  13. Chronic insertional Achilles tendinopathy: surgical outcomes

    OpenAIRE

    Oshri, Yael; Palmanovich, Ezequiel; Brin, Yaron Shagra; Karpf, Ronen; Massarwe, Sabri; Kish, Benny; Nyska, Meir

    2012-01-01

    Background and objective: insertional Achilles tendinopathy is a common condition among athletes and joggers. One fifth of the injuries involves the insertion of the tendon. The etiology is either due to mechanical overuse related to sports activity, or a systemic inflammatory disease. The clinical appearance includes pain and movement restriction. The primary treatment is conservative. The surgery referred to in this study (Calcaneal Osteotomy) is performed by decompression of the posterior ...

  14. Z-2 Threaded Insert Design and Testing

    Science.gov (United States)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  15. Pre-transplant soluble CD30 in combination with total DSA but not pre-transplant C1q-DSA predicts antibody-mediated graft loss in presensitized high-risk kidney transplant recipients.

    Science.gov (United States)

    Schaefer, S M; Süsal, C; Opelz, G; Döhler, B; Becker, L E; Klein, K; Sickmüller, S; Waldherr, R; Macher-Goeppinger, S; Schemmer, P; Beimler, J; Zeier, M; Morath, C

    2016-02-01

    Presensitized kidney transplant recipients are at high-risk for early antibody-mediated rejection. We studied the impact of pre- and post-transplant donor-specific human leukocyte antigen (HLA) antibodies (DSA) and T-cell-activation on the occurrence of antibody-mediated rejection episodes (AMR) and graft loss (AMR-GL) in a unique cohort of 80 desensitized high-risk kidney transplant recipients. Patients with pre-transplant DSA demonstrated more AMR episodes than patients without DSA, but did not show a significantly increased rate of AMR-GL. The rates of AMR and AMR-GL were not significantly increased in patients with complement split product (C1q)-binding pre-transplant DSA. Pre-transplant C1q-DSA became undetectable post-transplant in 11 of 13 (85%) patients; 2 (18%) of these 11 patients showed AMR but no AMR-GL. In contrast, the post-transplant presence of C1q-DSA was associated with significantly higher rates of AMR (86 vs 33 vs 0%; P transplant DSA without C1q-binding or the absence of DSA. Patients with both pre-transplant DSA and evidence of pre-transplant T-cell-activation as indicated by soluble CD30-positivity showed a significantly increased risk for AMR-GL [HR = 11.1, 95% confidence interval (CI) = 1.68-73.4; log-rank P = 0.013]. In these high-risk patients, AMR-GL was associated with total DSA in combination with T-cell-activation pre-transplant, and de novo or persistent C1q-binding DSA post-transplant. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  17. TF insert experiment log book. 2nd Experiment of CS model coil

    International Nuclear Information System (INIS)

    Sugimoto, Makoto; Isono, Takaaki; Matsui, Kunihiro

    2001-12-01

    The cool down of CS model coil and TF insert was started on August 20, 2001. It took almost one month and immediately started coil charge since September 17, 2001. The charge test of TF insert and CS model coil was completed on October 19, 2001. In this campaign, total shot numbers were 88 and the size of the data file in the DAS (Data Acquisition System) was about 4 GB. This report is a database that consists of the log list and the log sheets of every shot. This is an experiment logbook for 2nd experiment of CS model coil and TF insert for charge test. (author)

  18. Evaluation of blood loss after early or late release of ischemia in patients undergoing total knee replacement Avaliação da perda sanguínea após a liberação precoce ou tardia da isquemia em pacientes submetidos à artroplastia total do joelho

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    2013-04-01

    Full Text Available OBJECTIVE: compare blood loss in 40 patients underwent to unilateral total knee replacement with the release of ischemia before and after skin closure and compressive dressing. METHODS: in a prospective randomized study, in 40 patients underwent to total knee replacement, dividing then into two groups: group A in which the ischemia was released before skin closure, allowing bleeding control and group B where the ischemia was released after skin suture and pressure dressing. We compared the results of laboratory tests of serum hemoglobin before surgery and 48 hours postoperatively, the blood volume contained in vacuum suction drain and the transfusions that was necessary. RESULTS: As a result, the post operative serum hemoglobin levels had a mean decrease of 3.57 g/dL in group A and 4.24 g/dL in group B with an average of 0.67g/dL difference between them, statistically insignificant.The observed mean drainage, in the vacuum drain, were 705 mL in group A and 700 mL in group B. The 5ml difference between medians was considered statistically insignificant. The number of patients who received transfusions was four patients in both groups and all received two units of red blood cells. CONCLUSION: the post operative serum hemoglobin levels, as well as the need of blood transfusion, in the patient underwent to total knee replacement, where the ischemia was released before wound closure, has no statistical effect in comparison with patients where the sutures and bandages were done after the ischemia release. Level of Evidence IB - Individual randomized controlled trial with narrow confidence interval. OBJETIVO: Avaliar comparativamente a perda sanguínea em pacientes submetidos à artroplastia total do joelho, com liberação da isquemia antes e após suturas e curativo compressivo. MÉTODOS: Fez-se um estudo prospectivo randomizado em 40 pacientes submetidos à artroplastia total do joelho divididos em dois grupos. No primeiro grupo a isquemia foi

  19. Risk factors for development of complication following peripherally inserted central

    Directory of Open Access Journals (Sweden)

    Hakan Aydın

    2014-03-01

    Full Text Available Objectives: Peripherally inserted central venous catheters (PICCs are inserted into central veins through the upper extremity veins. In this retrospective study, we aimed to evaluate PICC procedures, related complications, their causes and factors influencing the success of the procedure during anaesthesia Methods: ‘Central Venous Catheterization Forms’ filled out for 850 patients in whom a PICC was inserted by residents during general anaesthesia between November 2009 and March 2013 in the operating room of Uludag University Medical Faculty Hospital were retrospectively analysed. Results: A total of 1174 procedures were evaluated. The most preferred vein for the first attempt was the right basilic vein (32.7%. Difficulty (more than two attempts with the PICC procedure was correlated with the patient’s age (p30 kg/m² (p<0.05, resident with less than 4 years of training (p=0.001, number of PICC attempts ≥2 (p<0.001, more than one resident involved in the catheterization procedure (p<0.001 and previous failed PICC procedures (p<0.001. Conclusion: We conclude that catheterization should be performed under the surveillance of a staff keeping in mind the risks of complications. In the case of failure following 2 attempts, the procedure should be handed over to a more experienced staff member. J Clin Exp Invest 2014; 5 (1: 29-35

  20. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    Science.gov (United States)

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (preadability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  1. RERTR-12 Insertion 1 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Lillo, M.A.; Chang, G.S.; Woolstenhulme, N.E.; Roth, G.A.; Wachs, D.M.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications. RERTR-12 insertion 1 includes the capsules irradiated during the first two irradiation cycles. These capsules include Z, X1, X2 and X3 capsules. The following report summarizes the life of the RERTR-12 insertion 1 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  2. RERTR-12 Insertion 2 Irradiation Summary Report

    International Nuclear Information System (INIS)

    Perez, D.M.; Chang, G.S.; Wachs, D.M.; Roth, G.A.; Woolstenhulme, N.E.

    2012-01-01

    The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.

  3. Installation of the LHC experimental insertions

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the low-beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  4. INSTALLATION OF THE LHC EXPERIMENTAL INSERTIONS

    CERN Document Server

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the Low-Beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  5. Compact insert design for cryogenic pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco; Petitpas, Guillaume; Switzer, Vernon A.

    2017-06-14

    A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.

  6. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  7. Energy losses in switches

    International Nuclear Information System (INIS)

    Martin, T.H.; Seamen, J.F.; Jobe, D.O.

    1993-01-01

    The authors experiments show energy losses between 2 and 10 times that of the resistive time predictions. The experiments used hydrogen, helium, air, nitrogen, SF 6 polyethylene, and water for the switching dielectric. Previously underestimated switch losses have caused over predicting the accelerator outputs. Accurate estimation of these losses is now necessary for new high-efficiency pulsed power devices where the switching losses constitute the major portion of the total energy loss. They found that the switch energy losses scale as (V peak I peak ) 1.1846 . When using this scaling, the energy losses in any of the tested dielectrics are almost the same. This relationship is valid for several orders of magnitude and suggested a theoretical basis for these results. Currents up to .65 MA, with voltages to 3 MV were applied to various gaps during these experiments. The authors data and the developed theory indicates that the switch power loss continues for a much longer time than the resistive time, with peak power loss generally occurring at peak current in a ranging discharge instead of the early current time. All of the experiments were circuit code modeled after developing a new switch loss version based on the theory. The circuit code predicts switch energy loss and peak currents as a function of time. During analysis of the data they noticed slight constant offsets between the theory and data that depended on the dielectric. They modified the plasma conductivity for each tested dielectric to lessen this offset

  8. Computer loss experience and predictions

    Science.gov (United States)

    Parker, Donn B.

    1996-03-01

    The types of losses organizations must anticipate have become more difficult to predict because of the eclectic nature of computers and the data communications and the decrease in news media reporting of computer-related losses as they become commonplace. Total business crime is conjectured to be decreasing in frequency and increasing in loss per case as a result of increasing computer use. Computer crimes are probably increasing, however, as their share of the decreasing business crime rate grows. Ultimately all business crime will involve computers in some way, and we could see a decline of both together. The important information security measures in high-loss business crime generally concern controls over authorized people engaged in unauthorized activities. Such controls include authentication of users, analysis of detailed audit records, unannounced audits, segregation of development and production systems and duties, shielding the viewing of screens, and security awareness and motivation controls in high-value transaction areas. Computer crimes that involve highly publicized intriguing computer misuse methods, such as privacy violations, radio frequency emanations eavesdropping, and computer viruses, have been reported in waves that periodically have saturated the news media during the past 20 years. We must be able to anticipate such highly publicized crimes and reduce the impact and embarrassment they cause. On the basis of our most recent experience, I propose nine new types of computer crime to be aware of: computer larceny (theft and burglary of small computers), automated hacking (use of computer programs to intrude), electronic data interchange fraud (business transaction fraud), Trojan bomb extortion and sabotage (code security inserted into others' systems that can be triggered to cause damage), LANarchy (unknown equipment in use), desktop forgery (computerized forgery and counterfeiting of documents), information anarchy (indiscriminate use of

  9. [Long-term follow-up after tympanostomy tube insertion in children with serous otitis media].

    Science.gov (United States)

    Fekete-Szabó, Gabriella; Kiss, Fekete; Rovó, László

    2015-11-15

    The authors report about the efficacy of inserted tympanostomy tube in children with serous otitis media. The aim of the authors was to assess the status of eardrum, the function of Eustachian tube and hearing level 10 years after the use of tympanostomy tube. Patients filled out a questionnaire and microscopic examination of tympanic membrane, tympanometry, Eustachian tube function examination, and audiometry tests were performed. In the period of 2003-2004, ventilation tube insertion was performed in 711 patients in the ENT Department of Pediatric Health Center of University of Szeged. In 349 patients adenotomy and tympanostomy tube insertion, in 18 cases tonsillectomy and grommet insertion and in 344 patients only typmanostomy tube insertion were performed. Due to objective difficulties (address change, no phone number) 453 patients were asked for control test and 312 persons accepted the invitation. Normal hearing level was found in 84.6% of patients and normal tympanometry result occurred in 82%. Tympanic ventilation disorder, perforation of tympanic membrane, sensorineural hearing loss and sensorineural hearing loss due to noise exposure were diagnosed. Application of tympanostomy tube is effective in the treatment of serous otitis media resulting from ventilation disorder. The authors draw attention to the importance of tympanometry examination to prevent the adhesive processes and cholesteatoma in chronic ventilation disorder of the middle ear.

  10. Da abordagem do TQM (Total Quality Management Ao GQM (Global Quality Management: a inserção e utilização da metodologia do projeto axiomático no desenvolvimento de modelos de gestão sistêmica da qualidade From the TQM (Total Quality Management approach to GQM (Global Quality Management: the insertion and utilization of the axiomatic design methodology in the development of a quality systemic management model

    Directory of Open Access Journals (Sweden)

    Felipe Araújo Calarge

    2001-08-01

    Full Text Available A palavra qualidade tem sido nos últimos anos sinônimo de sucesso ou fracasso em muitas empresas, sendo que esta situação resulta de como estas empresas compreendem os conceitos de qualidade. O desenvolvimento destes conceitos tem feito com que a qualidade deixe de ser simplesmente um meio de controle de produtos e processos, a fim de se desenvolver uma abordagem sistêmica de gestão da qualidade para toda a organização. O objetivo deste artigo é apresentar uma proposta de um modelo de gestão sistêmica da qualidade orientado pelas necessidades e atributos do cliente de uma empresa. No desenvolvimento deste trabalho é utilizado a abordagem do Projeto Axiomático, estabelecida em função de axiomas, corolários e teoremas, com o objetivo de implementar "boas práticas de projeto" na construção do modelo de gestão sistêmica da qualidade.In the past The the word quality has been in the past years synonymous of success or loss failure in many firms, and this situation is a results in of how these firms understanding the quality concepts. The development of these are responsible for a kind of quality that has simply last its original means concerning quality concepts has made that the quality abandons the simple way of products and processes control, in order to develop a systemic approach of quality management in the whole organization. The objective of this paper is to present a proposal of a quality systemic management model oriented by taking into account the firm's customer wants and attributes characteristics . In For the development of this work it is utilized the Axiomatic Design approach is used, which is established in function of axioms, corollaries and theorems, with the objective of to improve "good practices of design" in the construction of the quality systemic management model.

  11. Direct random insertion mutagenesis of Helicobacter pylori.

    NARCIS (Netherlands)

    Jonge, de R.; Bakker, D.; Vliet, van AH; Kuipers, E.J.; Vandenbroucke-Grauls, C.M.J.E.; Kusters, J.G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  12. Direct random insertion mutagenesis of Helicobacter pylori

    NARCIS (Netherlands)

    de Jonge, Ramon; Bakker, Dennis; van Vliet, Arnoud H. M.; Kuipers, Ernst J.; Vandenbroucke-Grauls, Christina M. J. E.; Kusters, Johannes G.

    2003-01-01

    Random insertion mutagenesis is a widely used technique for the identification of bacterial virulence genes. Most strategies for random mutagenesis involve cloning in Escherichia coli for passage of plasmids or for phenotypic selection. This can result in biased selection due to restriction or

  13. Aspects of insertion in random trees

    NARCIS (Netherlands)

    Bagchi, Arunabha; Reingold, E.M.

    1982-01-01

    A method formulated by Yao and used by Brown has yielded bounds on the fraction of nodes with specified properties in trees bult by a sequence of random internal nodes in a random tree built by binary search and insertion, and show that in such a tree about bounds better than those now known. We

  14. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research December 2015; 14 (12): ... Available online at http://www.tjpr.org ... patients/consumers about PPI. ... the perception of outpatients of Karachi about ... Do you store the medication at the temperature specified in the package insert ... drugs available in local market of Pakistan was.

  15. Preparation of the ITER Poloidal Field Conductor Insert (PFCI) test

    International Nuclear Information System (INIS)

    Zanino, R.; Egorov, S.; Kim, K.; Martovetsky, N.; Nunoya, Y.; Okuno, K.; Salpietro, E.; Sborchia, C.; Takahashi, Y.; Weng, P.; Bangasco, M.; Savoldi Richard, L.; Polak, M.; Formisano, A.; Zapretilina, E.; Shikov, A.; Vedernikov, G.; Ciazynski, D.; Zani, L.; Muzzi, L.; Ricci, M.; Deela Corte, A.; Sugimoto, M.; Hamada, K.; Portone, A.; Hurd, F.; Mitchell, N.; Nijhuis, A.; Ilyin, Y.

    2004-01-01

    The Poloidal Field Conductor Insert (PFCI) of the International Thermonuclear Experimental Reactor (ITER) has been designed in Europe and is being manufactured at Tesla Engineering, UK, in the frame of a Task Agreement with the ITER International Team. Completion of the PFCI is expected at the beginning of 2005. Then, the coil shall be shipped to JAERI Naka, Japan, and inserted into the bore of the ITER Central Solenoid Model Coil, where it should be tested in 2005 to 2006. The PFCI consists of a NbTi dual-channel conductor, almost identical to the ITER PF1 and PF6 design, about 45 m long, with a 50 mm thick square stainless steel jacket, wound in a single-layer solenoid. It should carry up to 50 kA in a field of about 6 T, and it will be cooled by supercritical He at around 4.5 K and 0.6 MPa. An intermediate joint, representative of the ITER PF joints and located at relatively high field, will be an important new item in the test configuration with respect to the previous ITER Insert Coils. The PFCI will be fully instrumented with inductive and resistive heaters, as well as with voltage taps, Hall probes, pick-up coils, temperature sensors, pressure taps, strain and displacement sensors. The test program shall be aimed at DC and pulsed performance assessment of conductor and intermediate joint, AC loss measurement, stability and quench propagation, thermalhydraulic characterization. Here we give an overview of the preparatory work towards the test, including a review of the coil manufacturing and of the available instrumentation, a discussion of the most likely test program items, and a presentation of the supporting modeling and characterization work performed so far. (authors)

  16. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  17. Insertional engineering of chromosomes with Sleeping Beauty transposition: an overview.

    Science.gov (United States)

    Grabundzija, Ivana; Izsvák, Zsuzsanna; Ivics, Zoltán

    2011-01-01

    Novel genetic tools and mutagenesis strategies based on the Sleeping Beauty (SB) transposable element are currently under development with a vision to link primary DNA sequence information to gene functions in vertebrate models. By virtue of its inherent capacity to insert into DNA, the SB transposon can be developed into powerful tools for chromosomal manipulations. Mutagenesis screens based on SB have numerous advantages including high throughput and easy identification of mutated alleles. Forward genetic approaches based on insertional mutagenesis by engineered SB transposons have the advantage of providing insight into genetic networks and pathways based on phenotype. Indeed, the SB transposon has become a highly instrumental tool to induce tumors in experimental animals in a tissue-specific -manner with the aim of uncovering the genetic basis of diverse cancers. Here, we describe a battery of mutagenic cassettes that can be applied in conjunction with SB transposon vectors to mutagenize genes, and highlight versatile experimental strategies for the generation of engineered chromosomes for loss-of-function as well as gain-of-function mutagenesis for functional gene annotation in vertebrate models.

  18. Experiencing Loss

    DEFF Research Database (Denmark)

    Kristiansen, Maria; Younis, Tarek; Hassani, Amani

    2015-01-01

    In this article, we explore how Islam, minority status and refugee experiencesintersect in shaping meaning-making processes following bereavement. We do this througha phenomenological analysis of a biographical account of personal loss told by Aisha, a Muslim Palestinian refugee living in Denmark......, who narrates her experience of losing herhusband to lung cancer. By drawing on a religious framework, Aisha creates meaning fromher loss, which enables her to incorporate this loss into her life history and sustain agency.Her narrative invites wider audiences to witness her tale of overcoming loss...

  19. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  20. The role of hinges in primary total knee replacement.

    Science.gov (United States)

    Gehrke, T; Kendoff, D; Haasper, C

    2014-11-01

    The use of hinged implants in primary total knee replacement (TKR) should be restricted to selected indications and mainly for elderly patients. Potential indications for a rotating hinge or pure hinge implant in primary TKR include: collateral ligament insufficiency, severe varus or valgus deformity (>20°) with necessary relevant soft-tissue release, relevant bone loss including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis, or hyperlaxity. Although data reported in the literature are inconsistent, clinical results depend on implant design, proper technical use, and adequate indications. We present our experience with a specific implant type that we have used for over 30 years and which has given our elderly patients good mid-term results. Because revision of implants with long cemented stems can be very challenging, an effort should be made in the future to use shorter stems in modular versions of hinged implants. ©2014 The British Editorial Society of Bone & Joint Surgery.

  1. Memory loss

    Science.gov (United States)

    ... barbiturates or ( hypnotics ) ECT (electroconvulsive therapy) (most often short-term memory loss) Epilepsy that is not well controlled Illness that ... appointment. Medical history questions may include: Type of memory loss, such as short-term or long-term Time pattern, such as how ...

  2. Symplectic models for general insertion devices

    International Nuclear Information System (INIS)

    Wu, Y.; Forest, E.; Robin, D. S.; Nishimura, H.; Wolski, A.; Litvinenko, V. N.

    2001-01-01

    A variety of insertion devices (IDs), wigglers and undulators, linearly or elliptically polarized,are widely used as high brightness radiation sources at the modern light source rings. Long and high-field wigglers have also been proposed as the main source of radiation damping at next generation damping rings. As a result, it becomes increasingly important to understand the impact of IDs on the charged particle dynamics in the storage ring. In this paper, we report our recent development of a general explicit symplectic model for IDs with the paraxial ray approximation. High-order explicit symplectic integrators are developed to study real-world insertion devices with a number of wiggler harmonics and arbitrary polarizations

  3. Agitation within Mk-42 insert caused by air sparge

    International Nuclear Information System (INIS)

    Ramsey, C.J.

    1991-01-01

    Dissolution of Rocky Flats Pu alloys and Pu metal using a ''nested insert'' configuration (One Well Insert (S-3352) inside the Mk-42 Insert) will require a Nuclear Safety Study, a major assumption of which will be that the annular dissolver is well-mixed. The ''well-mixed'' assumption was theoretically and experimentally supported for alloy dissolution using the Three Well Insert, but the present situation differs significantly. In the former case, the insert was directly exposed to the agitation induced by air sparging; in the case under consideration, the One Well Insert would be shielded by the Mk-42 Insert. In an effort to determine if the ''nested insert'' approach should be pursued, the past studies and technical literature have been surveyed and an attempt made to predict the extent of mixing and bulk circulation for a ''nested insert'' configuration in the presence of air sparging

  4. Avaliação da perda de mercúrio total em peixe antes e após os processos de fritura e cocção Determination of mercury losses in fish after cooking

    Directory of Open Access Journals (Sweden)

    Aricelso Maia LIMAVERDE FILHO

    1999-01-01

    Full Text Available A perda de mercúrio contido em músculo de peixes (Piraíba, Brachyplatystoma ssp; Traíra, Hoplias malabaricus submetidos a dois distintos processos de cozimento foi investigada. Os resultados mostraram perdas variando entre 0 e 30% (base seca, indicando que a maior parte do mercúrio foi retida. Assim, tais processos não protegem as populações, que deles se utilizam, contra a exposição por ingestão ao mercúrio originariamente contido na amostra "in natura".Mercury losses from flesh fish after two cooking process were investigated. Results showed losses ranging from 0 to 30% (dry weight basis. Such result indicates that fish consuming populations are not protected from mercury exposition by the studied cooking processes.

  5. Losses in variable fields

    International Nuclear Information System (INIS)

    Bronca, G.; Fevrier, A.; Genevey, P.; Perot, J.

    1974-01-01

    After a recall of the theory of losses in type 11 superconductors and review of recent work on this topic, the characteristics of what should be an ideal conductor for a pulsed magnet are given. The requirements of pulsed magnets for high energy physics are reviewed and total losses for a 1000 GeV synchrotron estimated. Finally, recent results of prototypes are reported along with the projects of superconducting synchrotron accelerators through the world. (author)

  6. Live insertion method used for main renewal

    International Nuclear Information System (INIS)

    Solkowitz, M.

    1992-01-01

    Baltimore Gas and Electric's pilot project using the live insertion method to replace a cast iron main provided excellent results. Its use on Eastern Avenue, a major state highway, was cost effective, provided gas service to customers during the work, required relatively short construction time and resulted in only minor traffic disruptions. Gas service transfers to the new main were done at customer convenience and resulted in outages of only a few hours per customer. This paper reports that the project involved inserting a 6-in. plastic line inside an existing 10-in. cast iron main. Miller Pipeline Corp., Indianapolis, supplier of the Insertec left-angle R right-angle live insertion method was contracted for the job. Miller technicians assisted BG and E forces by providing a load analysis of the main, a pushing machine and related supplies, foaming equipment and pipe cutting tools. Company forces were responsible for all preparatory work, including opening all excavations, installing bypasses, and fusing and testing the plastic pipe. Service transfers and renewals were also completed by company employees

  7. App-assisted external ventricular drain insertion.

    Science.gov (United States)

    Eftekhar, Behzad

    2016-09-01

    The freehand technique for insertion of an external ventricular drain (EVD) is based on fixed anatomical landmarks and does not take individual variations into consideration. A patient-tailored approach based on augmented-reality techniques using devices such as smartphones can address this shortcoming. The Sina neurosurgical assist (Sina) is an Android mobile device application (app) that was designed and developed to be used as a simple intraoperative neurosurgical planning aid. It overlaps the patient's images from previously performed CT or MRI studies on the image seen through the device camera. The device is held by an assistant who aligns the images and provides information about the relative position of the target and EVD to the surgeon who is performing EVD insertion. This app can be used to provide guidance and continuous monitoring during EVD placement. The author describes the technique of Sina-assisted EVD insertion into the frontal horn of the lateral ventricle and reports on its clinical application in 5 cases as well as the results of ex vivo studies of ease of use and precision. The technique has potential for further development and use with other augmented-reality devices.

  8. Comparison of trapezius squeeze test and jaw thrust as clinical indicators for laryngeal mask airway insertion in spontaneously breathing children

    Science.gov (United States)

    Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya

    2017-01-01

    Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275

  9. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  10. Laparoscopic total pancreatectomy

    Science.gov (United States)

    Wang, Xin; Li, Yongbin; Cai, Yunqiang; Liu, Xubao; Peng, Bing

    2017-01-01

    Abstract Rationale: Laparoscopic total pancreatectomy is a complicated surgical procedure and rarely been reported. This study was conducted to investigate the safety and feasibility of laparoscopic total pancreatectomy. Patients and Methods: Three patients underwent laparoscopic total pancreatectomy between May 2014 and August 2015. We reviewed their general demographic data, perioperative details, and short-term outcomes. General morbidity was assessed using Clavien–Dindo classification and delayed gastric emptying (DGE) was evaluated by International Study Group of Pancreatic Surgery (ISGPS) definition. Diagnosis and Outcomes: The indications for laparoscopic total pancreatectomy were intraductal papillary mucinous neoplasm (IPMN) (n = 2) and pancreatic neuroendocrine tumor (PNET) (n = 1). All patients underwent laparoscopic pylorus and spleen-preserving total pancreatectomy, the mean operative time was 490 minutes (range 450–540 minutes), the mean estimated blood loss was 266 mL (range 100–400 minutes); 2 patients suffered from postoperative complication. All the patients recovered uneventfully with conservative treatment and discharged with a mean hospital stay 18 days (range 8–24 days). The short-term (from 108 to 600 days) follow up demonstrated 3 patients had normal and consistent glycated hemoglobin (HbA1c) level with acceptable quality of life. Lessons: Laparoscopic total pancreatectomy is feasible and safe in selected patients and pylorus and spleen preserving technique should be considered. Further prospective randomized studies are needed to obtain a comprehensive understanding the role of laparoscopic technique in total pancreatectomy. PMID:28099344

  11. Systematic review: Radiological and histological evidence of cochlear implant insertion trauma in adult patients.

    Science.gov (United States)

    Hoskison, Emma; Mitchell, Scott; Coulson, Chris

    2017-07-01

    Cochlear implantation (CI) has developed from its origins in the 1980s. Initially, CI was for profound bilateral hearing impairment. However, candidacy for CI have become more widespread in recent years with unilateral implantation and an emphasis on hearing preservation. Evidence supports full electrode insertion in an atraumatic fashion into the scala tympani (ST) provides optimal hearing outcomes. The main aim of this systematic review was to elucidate the degree of trauma associated with CI insertion. A systematic literature search was undertaken using PubMed Medline. A grading system described by Eshraghi was used to classify cochlear trauma. Both radiological and histological studies were included. Twenty one papers were identified which were relevant to our search. In total, 653 implants were inserted and 115 (17.6%) showed evidence of trauma. The cochleas with trauma had basilar membrane elevation in 5.2%, ruptured in 5.2%, the electrode passed from the ST to the SV in 84.4% and there was grade 4 trauma in 5.2%. The studies used a variety of histological and radiological methods to assess for evidence of trauma in both cadaveric temporal bones and live recipients. Minimizing cochlear trauma during implant insertion is important to preserve residual hearing and optimize audiological performance. An overall 17.6% trauma rate suggests that CI insertion could be improved with more accurate and consistent electrode insertion such as in the form of robotic guidance. The correlation of cochlea trauma with post-operative hearing has yet to be determined.

  12. Effect of Needle Aspiration of Pneumothorax on Subsequent Chest Drain Insertion in Newborns

    DEFF Research Database (Denmark)

    Murphy, Madeleine C; Heiring, Christian; Doglioni, Nicoletta

    2018-01-01

    Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating pneumotho......Importance: Treatment options for a symptomatic pneumothorax in newborns include needle aspiration (NA) and chest drain (CD) insertion. There is little consensus as to the preferred treatment, reflecting a lack of evidence from clinical trials. Objective: To investigate whether treating...... was 5 tertiary European neonatal intensive care units. Infants receiving respiratory support (endotracheal ventilation, continuous positive airway pressure, or supplemental oxygen >40%) who had a pneumothorax on CR that clinicians deemed needed treatment were eligible for inclusion. Interventions...... was inserted if clinicians deemed that the response was inadequate. For CD insertion, a drain was inserted between the ribs and was left in situ. Main Outcomes and Measures: The primary outcome was whether a CD was inserted on the side of the pneumothorax within 6 hours of diagnosis. Results: A total of 76...

  13. Weight Loss

    Science.gov (United States)

    ... Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home Food MyFoodAdvisor ... Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food Choices In My Community Home ...

  14. Validation of a Low Cost, Disposable, and Ultrasound-guided Suprapubic Catheter Insertion Trainer.

    Science.gov (United States)

    Nonde, James; Adam, Ahmed; Laher, Abdullah Ebrahim

    2018-02-27

    To validate the newly designed ultrasound-guided suprapubic catheter insertion trainer (US-SCIT) model against the real life experience by enrolling participants with prior confidence in the technique of US-guided suprapubic catheter (SPC) insertion. The US-SCIT was self-constructed from common disposables and equipment found in the emergency department. A validation questionnaire was completed by all participants after SPC insertion on the US-SCIT model. Fifty participants enrolled in the study. Each participant had reported confidence in the SPC insertion technique, prior to participation in this study. There were 13 "super-users" (>65 previous successful real life SPC insertions) in the study. The total material cost per US-SCIT unit was 1.71 USD. The US-SCIT's value in understanding the principals of US-guided SPC insertion had a mean score of 8.86 (standard deviation [SD] 1.03), whereas its value in simulating contextual anatomy had a mean score of 8.26 (SD 1.48). The mean score of the model's ability to provide realistic sensory feedback was 8.12 (SD 1.78), whereas that of realism of initial urine outflow was 9.06 (SD 1.20). Simulation with the model compared well with real life SPC insertion, with a mean score of 8.30 (SD1.48). The US-SCIT model performed well in various spheres developed to assess its ability to simulate real life SPC insertion. We are confident that this low-cost, validated, US compatible SPC trainer, constructed from common material present in the ED, will be a valuable learning asset to trainees across the globe. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. A novel intergenic ETnII-β insertion mutation causes multiple malformations in polypodia mice.

    Directory of Open Access Journals (Sweden)

    Jessica A Lehoczky

    Full Text Available Mouse early transposon insertions are responsible for ~10% of spontaneous mutant phenotypes. We previously reported the phenotypes and genetic mapping of Polypodia, (Ppd, a spontaneous, X-linked dominant mutation with profound effects on body plan morphogenesis. Our new data shows that mutant mice are not born in expected Mendelian ratios secondary to loss after E9.5. In addition, we refined the Ppd genetic interval and discovered a novel ETnII-β early transposon insertion between the genes for Dusp9 and Pnck. The ETn inserted 1.6 kb downstream and antisense to Dusp9 and does not disrupt polyadenylation or splicing of either gene. Knock-in mice engineered to carry the ETn display Ppd characteristic ectopic caudal limb phenotypes, showing that the ETn insertion is the Ppd molecular lesion. Early transposons are actively expressed in the early blastocyst. To explore the consequences of the ETn on the genomic landscape at an early stage of development, we compared interval gene expression between wild-type and mutant ES cells. Mutant ES cell expression analysis revealed marked upregulation of Dusp9 mRNA and protein expression. Evaluation of the 5' LTR CpG methylation state in adult mice revealed no correlation with the occurrence or severity of Ppd phenotypes at birth. Thus, the broad range of phenotypes observed in this mutant is secondary to a novel intergenic ETn insertion whose effects include dysregulation of nearby interval gene expression at early stages of development.

  16. Genomic rearrangements by LINE-1 insertion-mediated deletion in the human and chimpanzee lineages.

    Science.gov (United States)

    Han, Kyudong; Sen, Shurjo K; Wang, Jianxin; Callinan, Pauline A; Lee, Jungnam; Cordaux, Richard; Liang, Ping; Batzer, Mark A

    2005-01-01

    Long INterspersed Elements (LINE-1s or L1s) are abundant non-LTR retrotransposons in mammalian genomes that are capable of insertional mutagenesis. They have been associated with target site deletions upon insertion in cell culture studies of retrotransposition. Here, we report 50 deletion events in the human and chimpanzee genomes directly linked to the insertion of L1 elements, resulting in the loss of approximately 18 kb of sequence from the human genome and approximately 15 kb from the chimpanzee genome. Our data suggest that during the primate radiation, L1 insertions may have deleted up to 7.5 Mb of target genomic sequences. While the results of our in vivo analysis differ from those of previous cell culture assays of L1 insertion-mediated deletions in terms of the size and rate of sequence deletion, evolutionary factors can reconcile the differences. We report a pattern of genomic deletion sizes similar to those created during the retrotransposition of Alu elements. Our study provides support for the existence of different mechanisms for small and large L1-mediated deletions, and we present a model for the correlation of L1 element size and the corresponding deletion size. In addition, we show that internal rearrangements can modify L1 structure during retrotransposition events associated with large deletions.

  17. Deep round window insertion versus standard approach in cochlear implant surgery.

    Science.gov (United States)

    Nordfalk, Karl Fredrik; Rasmussen, Kjell; Bunne, Marie; Jablonski, Greg Eigner

    2016-01-01

    The aim of this study was to compare the outcomes of vestibular tests and the residual hearing of patients who have undergone full insertion cochlear implant surgery using the round window approach with a hearing preservation protocol (RW-HP) or the standard cochleostomy approach (SCA) without hearing preservation. A prospective study of 34 adults who underwent unilateral cochlear implantation was carried out. One group was operated using the RW-HP (n = 17) approach with Med-El +Flex(SOFT) electrode array with full insertion, while the control group underwent a more conventional SCA surgery (n = 17) with shorter perimodiolar electrodes. Assessments of residual hearing, cervical vestibular-evoked myogenic potentials (cVEMP), videonystagmography, subjective visual vertical/horizontal (SVH/SVV) were performed before and after surgery. There was a significantly (p < 0.05) greater number of subjects who exhibited complete or partial hearing preservation in the deep insertion RW-HP group (9/17) compared to the SCA group (2/15). A higher degree of vestibular loss but a lower degree of vertigo symptoms could be seen in the RW-HP group, but the differences were not statistically significant. It is possible to preserve residual hearing to a certain extent also with deep insertion. Full insertion with hearing preservation was less harmful to residual hearing particularly at 125 Hz (p < 0.05), than was the standard cochleostomy approach.

  18. Probabilistic analysis of canister inserts for spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Dillstroem, Peter [Det Norske Veritas, Stockholm (Sweden)

    2005-10-01

    In this study, probabilistic analysis of canister inserts for spent nuclear fuel has been performed. The main conclusions are: 1. For the baseline case, the probability of failure is insignificant ({approx} 2x10{sup -9}). This is the case even though several conservative assumptions have been made both in underlying deterministic analysis and in the probabilistic analysis. 2. The initiation event dominates (over the local collapse event) when the external pressure is below the baseline case (p = 44 MPa). The local collapse event dominates when the external pressure is above the baseline case. 3. The local collapse event is strongly dependent of the assumed external pressure. 4. The analysis of collapse only considers the first local collapse event, total collapse of the insert will occur at a much higher pressure. 5. The resulting probabilities are more dependent on the assumption regarding the eccentricity of the cassette than the assumption regarding outer corner radius of the profiles for steel section cassette. The results indicate that the maximum allowed eccentricity should not be larger than 5 mm. 6. The probability of initiation of crack growth is calculated using a defect distribution where one assumes the existence of one crack-like defect. A simple scaling argument can be applied to consider the number of defects through the thickness.

  19. Probabilistic analysis of canister inserts for spent nuclear fuel

    International Nuclear Information System (INIS)

    Dillstroem, Peter

    2005-10-01

    In this study, probabilistic analysis of canister inserts for spent nuclear fuel has been performed. The main conclusions are: 1. For the baseline case, the probability of failure is insignificant (∼ 2x10 -9 ). This is the case even though several conservative assumptions have been made both in underlying deterministic analysis and in the probabilistic analysis. 2. The initiation event dominates (over the local collapse event) when the external pressure is below the baseline case (p = 44 MPa). The local collapse event dominates when the external pressure is above the baseline case. 3. The local collapse event is strongly dependent of the assumed external pressure. 4. The analysis of collapse only considers the first local collapse event, total collapse of the insert will occur at a much higher pressure. 5. The resulting probabilities are more dependent on the assumption regarding the eccentricity of the cassette than the assumption regarding outer corner radius of the profiles for steel section cassette. The results indicate that the maximum allowed eccentricity should not be larger than 5 mm. 6. The probability of initiation of crack growth is calculated using a defect distribution where one assumes the existence of one crack-like defect. A simple scaling argument can be applied to consider the number of defects through the thickness

  20. Per-operative vibration analysis: a valuable tool for defining correct stem insertion: preliminary report.

    Science.gov (United States)

    Mulier, Michiel; Pastrav, Cesar; Van der Perre, Georges

    2008-01-01

    Defining the stem insertion end point during total hip replacement still relies on the surgeon's feeling. When a custom-made stem prosthesis with an optimal fit into the femoral canal is used, the risk of per-operative fractures is even greater than with standard prostheses. Vibration analysis is used in other clinical settings and has been tested as a means to detect optimal stem insertion in the laboratory. The first per-operative use of vibration analysis during non-cemented custom-made stem insertion in 30 patients is reported here. Thirty patients eligible for total hip replacement with uncemented stem prosthesis were included. The neck of the stem was connected with a shaker that emitted white noise as excitation signal and an impedance head that measured the frequency response. The response signal was sent to a computer that analyzed the frequency response function after each insertion phase. A technician present in the operating theatre but outside the laminated airflow provided feed-back to the surgeon. The correlation index between the frequency response function measured during the last two insertion hammering sessions was >0.99 in 86.7% of the cases. In four cases the surgeon stopped the insertion procedure because of a perceived risk of fracture. Two special cases illustrating the potential benefit of per-operative vibration analysis are described. The results of intra-operative vibration analysis indicate that this technique may be a useful tool assisting the orthopaedic surgeon in defining the insertion endpoint of the stem. The development of a more user-friendly device is therefore warranted.

  1. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  2. Atomistic Galois insertions for flow sensitive integrity

    DEFF Research Database (Denmark)

    Nielson, Flemming; Nielson, Hanne Riis

    2017-01-01

    Several program verification techniques assist in showing that software adheres to the required security policies. Such policies may be sensitive to the flow of execution and the verification may be supported by combinations of type systems and Hoare logics. However, this requires user assistance...... and to obtain full automation we shall explore the over-approximating nature of static analysis. We demonstrate that the use of atomistic Galois insertions constitutes a stable framework in which to obtain sound and fully automatic enforcement of flow sensitive integrity. The framework is illustrated...

  3. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  4. Effect of embedded dexamethasone in cochlear implant array on insertion forces in an artificial model of scala tympani.

    Science.gov (United States)

    Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier

    2015-02-01

    Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.

  5. Hidden loss

    DEFF Research Database (Denmark)

    Kieffer-Kristensen, Rikke; Johansen, Karen Lise Gaardsvig

    2013-01-01

    to participate. RESULTS: All children were affected by their parents' ABI and the altered family situation. The children's expressions led the authors to identify six themes, including fear of losing the parent, distress and estrangement, chores and responsibilities, hidden loss, coping and support. The main......PRIMARY OBJECTIVE: The purpose of this study was to listen to and learn from children showing high levels of post-traumatic stress symptoms after parental acquired brain injury (ABI), in order to achieve an in-depth understanding of the difficulties the children face in their everyday lives...... finding indicates that the children experienced numerous losses, many of which were often suppressed or neglected by the children to protect the ill parents. CONCLUSIONS: The findings indicated that the children seemed to make a special effort to hide their feelings of loss and grief in order to protect...

  6. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  7. Targeted gene insertion for molecular medicine.

    Science.gov (United States)

    Voigt, Katrin; Izsvák, Zsuzsanna; Ivics, Zoltán

    2008-11-01

    Genomic insertion of a functional gene together with suitable transcriptional regulatory elements is often required for long-term therapeutical benefit in gene therapy for several genetic diseases. A variety of integrating vectors for gene delivery exist. Some of them exhibit random genomic integration, whereas others have integration preferences based on attributes of the targeted site, such as primary DNA sequence and physical structure of the DNA, or through tethering to certain DNA sequences by host-encoded cellular factors. Uncontrolled genomic insertion bears the risk of the transgene being silenced due to chromosomal position effects, and can lead to genotoxic effects due to mutagenesis of cellular genes. None of the vector systems currently used in either preclinical experiments or clinical trials displays sufficient preferences for target DNA sequences that would ensure appropriate and reliable expression of the transgene and simultaneously prevent hazardous side effects. We review in this paper the advantages and disadvantages of both viral and non-viral gene delivery technologies, discuss mechanisms of target site selection of integrating genetic elements (viruses and transposons), and suggest distinct molecular strategies for targeted gene delivery.

  8. Cigarette Mouth Insertion Depths Among Chinese Smokers

    Directory of Open Access Journals (Sweden)

    Hu Q

    2014-12-01

    Full Text Available Vent blocking - where filter ventilation holes are intentionally or unintentionally, partly or completely covered by smokers’ lips during smoking - is an aspect of smoking behavior which can alter mainstream smoke yields. This study was designed to determine if, and to what extent ventilation holes were blocked by smokers’ lips in two cohorts of Chinese smokers. In this study, two groups of samples were collected. One group (1742 butts was collected randomly from public places in six chosen cities. Another (1037 butts was obtained by collecting the butts from identified smokers in Kunming. In this paper, the mouth insertion depth among Chinese smokers was studied for the first time by a staining method employing ninhydrin in ethanol. The results indicate that Chinese smokers exhibit a mouth insertion depth ranging from 1 to 17 mm with an average value of 7.5 AA± 2 mm. In this study, 95% of the ventilated filters examined showed that the vent zone was neither completely nor partially covered by smokers’ lips.

  9. Safety analysis for reactivity insertion on ADS

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcia S.; Velasquez, Carlos E.; Pereira, Claubia; Veloso, Maria Auxiliadora F.; Costa, Antonella L. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Barros, Graiciany de P. [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    In this work, an accelerator driven system (ADS) has been studied to fuel regeneration, partitioning and transmutation using fuel removed from LWR-spent fuel. This spent fuel was reprocessed by GANEX and then spiked with thorium. Monteburns 2.0 (MCNP5/ORIGEN 2.1) code was used to simulate burnup and neutronic parameters of the systems. However, these systems might be interrupted for some technical problems during few days or long periods to perform maintenance of accelerator systems without shutdown the fission system. Therefore, in this work, the aim was to investigate the nuclear fuel evolution in three different cases with reactivity insertions and variations in the functionality of the ADS. The evaluation has been performed for a burnup of 3 years, which are the most dangerous years in case of reactivity insertions. Therefore, in the first case the ADS during its burnup the external source (spallation source) is cutting off from the system several times during the first year of burnup. In the second case, it is simulated the reactor at different power from 0 (shutdown) to 1.5 times the 515MWt. The results shows the safety limits of the ADS for different situation. (author)

  10. Normal Conducting Separation Dipoles for the LHC Beam Cleaning Insertions

    CERN Document Server

    Bidon, S; Hans, O; Kalbreier, Willi; Kiselev, O; Petrov, V; Protopopov, I V; Pupkov, Yu A; Ramberger, S; de Rijk, G; Ruvinsky, E; Sukhanov, A

    2004-01-01

    In the Large Hadron Collider (LHC), two straight sections, IR3 and IR7, will be dedicated to beam cleaning. These cleaning insertions will be equipped with normal conducting magnets. MBW magnets are dipole magnets used to increase the separation of the two beams. They have a core length of 3.4 m and a gap height of 52 mm and will operate at a magnetic field ranging from 0.09 T to 1.53 T. Limitations on the dimensions and total weight of the magnet resulted in a special design with a common yoke for the two beams. The orbits of the two beams will be separated horizontally by a distance between 194 mm and 224 mm in the gap of the magnet. The magnet was designed in collaboration between CERN and BINP. The report presents the main design issues and results of the pre-series acceptance tests including mechanical, electrical and magnetic field measurements.

  11. Factors influencing initial cup stability in total hip arthroplasty.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  13. Nb3Al insert experiment log book. 3rd experiment of CS model coil

    International Nuclear Information System (INIS)

    Sugimoto, Makoto; Koizumi, Norikiyo; Isono, Takaaki

    2002-10-01

    The cool down of CS model coil and Nb 3 Al insert was started on March 4, 2002. It took almost one month and immediately started coil charge since April 3, 2002. The charge test of Nb 3 Al insert and CS model coil was completed on May 2, 2002. All of the experiments including the warm up was also completed on May 30, 2002. In this campaign, total shot numbers were 102 and the size of the data file in the DAS (Data Acquisition System) was about 5.2 GB. This report is a database that consists of the log list and the log sheets of every shot. (author)

  14. Method Of Wire Insertion For Electric Machine Stators

    Science.gov (United States)

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  15. Total 2003 Results

    International Nuclear Information System (INIS)

    2003-01-01

    This document presents the 2003 results of Total Group: consolidated account, special items, number of shares, market environment, 4. quarter 2003 results, full year 2003 results, upstream (key figures, proved reserves), downstream key figures, chemicals key figures, parent company accounts and proposed dividends, 2004 sensitivities, summary and outlook, operating information by segment for the 4. quarter and full year 2003: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refinery throughput by region, refined product sales by region, chemicals), impact of allocating contribution of Cepsa to net operating income by business segment: equity in income (loss) and affiliates and other items, Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  16. Hand-actuated spring clip insertion tool

    International Nuclear Information System (INIS)

    Cuba, G.W.

    1993-01-01

    A hand-actuated insertion tool includes a handle assembly, an elongated hollow tubular outer support tube, an elongated inner pull rod, and a coupling arrangement. The handle assembly has a first handle member and a second handle member pivoted to a member for movement between unactuated and actuated positions. The tube is attached in a fixed relation to a handle member. The rod is mounted within the tube for sliding movement relative thereto between home and retracted positions. The coupling arrangement pivotally connects the rod to the second handle member such that the rod will undergo sliding movement from the home position to the retracted positions relative to the tube as the second handle member is moved from the unactuated position to the actuated position adjacent to the first handle member. (author)

  17. MORPH INSERTION AND ALLOMORPHY IN OPTIMALITY THEORY

    Directory of Open Access Journals (Sweden)

    Eulalia Bonet

    2004-12-01

    Full Text Available The goal of this paper is to compare two different hypotheses about the insertion of morphs and allomorphy in Optimality Theory. One of them, the Morphs through Constraifits Hypothesis (MCH claims that the phonological realization of morphemes (morphs is introduced through language-particular constraints. The other hypothesis, the Morphs in the Input Hypothesis (MIH claims that the inputs to GEN contain al1 the relevant phonological information. It is shown that the MIH is clearly superior to the MCH in accounting for voicing neutralization in languages like Catalan. The two hypotheses seem to fare even in dealing with other phenomena, such as phonologically-conditioned allomorphy or OCP-triggered epenthesis vs. haplology in English possessives and plurals. Finally, although the MCH seems to be a simpler hypothesis for lexical exceptions, it is shown that, when certain aspects are taken into account, it runs into problems.

  18. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  19. Cassini-Huygens Nears Saturn Orbit Insertion

    Science.gov (United States)

    Showstack, Randy

    2004-06-01

    After nearly 7 years and a 3.5-billion-km, circuitous journey from Earth, the $3-billion Cassini-Huygens mission to Saturn and Titan-an international effort by NASA, the European Space Agency, and the Italian Space Agency-now is just days away from its critical Saturn orbit insertion. Scheduled for 30 June, this will begin the 4-years part of the mission to study the Saturnian system. At a 3 June briefing at NASA headquarters in Washington, D.C., Robert Mitchell, the Cassini program manager with the Jet Propulsion Laboratory in Pasadena, California, said that scientists involved with the program are feeling excited, relieved, and also a bit anxious as the Cassini-Huygens spacecraft draws near to the ringed planet and its system.

  20. Insertion Device Upgrade Plans at the NSLS

    CERN Document Server

    Tanabe, Toshiya; Harder, David; Lehecka, Michael; Rakowsky, George; Skaritka, John

    2005-01-01

    This paper describes plans to upgrade insertion devices at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, U.S.A. The aging wiggler (W80) at X25 is being replaced by a 1 m long in-vacuum mini-gap undulator (MGU-18) optimized for a dedicated macromolecular crystallography program. A new, 1/3 m long, in-vacuum undulator (MGU-13.5), will be installed between a pair of RF cavities at X9, and will serve a new beamline dedicated for small angle x-ray scattering (SAXS). Both MGU’s will have provision for cryocooling the NdFeB hybrid arrays to 150K to raise the field and K-value and to obtain better spectral coverage. Design issues of the devices and other considerations, especially magnetic measurement methods in low temperature will be discussed.

  1. Quench Performance of the LHC Insertion Magnets

    CERN Document Server

    Lasheras, N C; Siemko, A; Ostojic, R; Kirby, G

    2009-01-01

    After final installation in the LHC tunnel, the MQM and MQY quadrupole magnets of the LHC insertions are now being commissioned to their nominal currents. These two types of magnets operate at 1.9 K and 4.5 K and with nominal currents ranging from 3600 A to 5390 A. From the very first acceptance tests of the bare magnets coming from the manufacturers, they have been powered using different cycles, in different configurations, at different temperatures and in different tests facilities. In this paper we present the global results of these powering tests. We aim at separating common from individual features of these groups of magnets. Temperature dependence of the training, temperature margin, and ultimate current can be extracted from these tests. As these magnets are used to match the optics and the dispersion in the machine, the projected ultimate current at which they can be operated is critical in view of operation of LHC.

  2. A novel method for improving chest tube insertion skills among medical interns

    Science.gov (United States)

    Tatli, Ozgur; Turkmen, Suha; Imamoglu, Melih; Karaca, Yunus; Cicek, Mustafa; Yadigaroglu, Metin; Bayrak, Selen T.; Asik, Olgun; Topbas, Murat; Turedi, Suleyman

    2017-01-01

    Objectives: To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42). Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand. PMID:28917064

  3. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    Science.gov (United States)

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. A new robotic needle insertion method to minimise attendant prostate motion

    International Nuclear Information System (INIS)

    Lagerburg, Vera; Moerland, Marinus A.; Vulpen, Marco van; Lagendijk, Jan J.W.

    2006-01-01

    Background and purpose: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. Material and methods: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. Results: The mean prostate motion was 5.6 mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p < 0.001). Conclusion: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system

  5. Quantification of Tissue Trauma following Insulin Pen Needle Insertions in Skin

    DEFF Research Database (Denmark)

    Jensen, Casper Bo; Larsen, Rasmus; Vestergaard, Jacob Schack

    Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop a computa......Objective: Within the field of pen needle development, most research on needle design revolves around mechanical tensile testing and patient statements. Only little has been published on the actual biological skin response to needle insertions. The objective of this study was to develop...... a computational method to quantify tissue trauma based on skin bleeding and immune response. Method: Two common sized pen needles of 28G (0.36mm) and 32G (0.23mm) were inserted into skin of sedated LYD pigs prior to termination. Four pigs were included and a total of 32 randomized needle insertions were conducted...... diameter. Conclusion: A computational and quantitative method has been developed to assess tissue trauma following insulin pen needle insertions. Application of the method is tested by conduction of a needle diameter study. The obtained quantitative measures of tissue trauma correlate positively to needle...

  6. Metal stents insertion in the treatment of the patients with benign oesophageal strictures

    International Nuclear Information System (INIS)

    Valek, V.; Benda, K.; Hrobar, P.; Mrazova, J.; Prasek, J.; Vomela, J.; Muenzova, H.; Hep, A.; Stefl, M.

    1996-01-01

    Between October 1993 and June 1995 the authors inserted in the Department of Radiology in University Hospital Bohunice in 16 of their patients with benign stenosis of the oesophagus an expandable metals stent. the aetiology of the stenosis was long-term reflux oesophagitis (6x), postoperative benign stenosis in anastomosis (3x), corrosive structure (2x), epidermolysis bulosa oesophagi (2x) and post-radiation structure (1x). In two patients the aetiology of the stenosis was unknown. All the patients suffered at the the of the stent insertion from marked dysphagia (stage 3 and/or 4). The indication for oesophageal stent implantation was always carefully considered by an interdisciplinary indication committee. Before the stent insertion all the stenoses have been repeatedly unsuccessfully dilated with balloon dilatation catheter. In total, 25 stents were used. In seven patients were inserted more as one stent. The intervention itself was preceded by a double contrast X-ray examination of oesophagus, oesophagoscopy with biopsy to verify the stricture aetiology, computed tomography and endosonography. No complications associated with the intervention have been encountered and stent insertions have always been well tolerated. (authors). 1 tab., 3 figs., 9 refs

  7. Human-specific HERV-K insertion causes genomic variations in the human genome.

    Directory of Open Access Journals (Sweden)

    Wonseok Shin

    Full Text Available Human endogenous retroviruses (HERV sequences account for about 8% of the human genome. Through comparative genomics and literature mining, we identified a total of 29 human-specific HERV-K insertions. We characterized them focusing on their structure and flanking sequence. The results showed that four of the human-specific HERV-K insertions deleted human genomic sequences via non-classical insertion mechanisms. Interestingly, two of the human-specific HERV-K insertion loci contained two HERV-K internals and three LTR elements, a pattern which could be explained by LTR-LTR ectopic recombination or template switching. In addition, we conducted a polymorphic test and observed that twelve out of the 29 elements are polymorphic in the human population. In conclusion, human-specific HERV-K elements have inserted into human genome since the divergence of human and chimpanzee, causing human genomic changes. Thus, we believe that human-specific HERV-K activity has contributed to the genomic divergence between humans and chimpanzees, as well as within the human population.

  8. Greece reports prototype intervention with first peripherally inserted central catheter: case report and literature review.

    Science.gov (United States)

    Konstantinou, Evangelos A; Stafylarakis, Emmanuil; Kapritsou, Maria; Mitsos, Aristotelis P; Fotis, Theofanis G; Kiekkas, Panagiotis; Mariolis-Sapsakos, Theodoros; Argyras, Eriphyli; Nomikou, Irini Th; Dimitrakopoulos, Antonios

    2012-09-01

    Placement of peripherally inserted central catheters (PICCs), definitely offers a clear advantage over any other method regarding central venous catheterization. Its ultrasonographic orientation enhances significantly its accuracy, safety and efficacy, making this method extremely comfortable for the patient who can continue his or her therapy even in an outpatient basis. We present the first reported case of a PICCS insertion in Greece, which has been performed by a university-degree nurse. The aim of this review of literature was to present the evolution in nursing practice in Greece. A PICC was inserted in a 77-year-old male patient suffering from a recent chemical pneumonia with a history of Alzheimer's disease. A description of all the technical details of this insertion is reported, focusing on the pros and cons of the method and a thorough review of the history and advances in central venous catheterization throughout the years is also presented. PICCs provide long-term intravenous access and facilitate the delivery of extended antibiotic therapy, chemotherapy and total parenteral nutrition. We strongly believe that PICCs are the safest and most effective method of peripherally inserted central venous catheterization. Larger series are necessary to prove the above hypothesis, and they are under construction by our team. Copyright © 2012 Society for Vascular Nursing, Inc. Published by Mosby, Inc. All rights reserved.

  9. Backside wear in modern total knee designs.

    Science.gov (United States)

    Jayabalan, Prakash; Furman, Bridgette D; Cottrell, Jocelyn M; Wright, Timothy M

    2007-02-01

    Although modularity affords various options to the orthopedic surgeon, these benefits come at a price. The unintended bearing surface between the back surface of the tibial insert and the metallic tray results in micromotion leading to polyethylene wear debris. The objective of this study was to examine the backside wear of tibial inserts from three modern total knee designs with very different locking mechanisms: Insall-Burstein II (IB II), Optetrak, and Advance. A random sample of 71 inserts were obtained from our institution's retrieval collection and examined to assess the extent of wear, depth of wear, and wear damage modes. Patient records were also obtained to determine patient age, body mass index, length of implantation, and reason for revision. Modes of wear damage (abrasion, burnishing, scratching, delamination, third body debris, surface deformation, and pitting) were then scored in each zone from 0 to 3 (0 = 0%, 1 = 0-10%, 2 = 10-50%, and 3 = >50%). The depth of wear was subjectively identified as removal of manufacturing identification markings stamped onto the inferior surface of the polyethylene. Both Advance and IB II polyethylene inserts showed significantly higher scores for backside wear than the Optetrak inserts. All IB II and Advance implants showed evidence of backside wear, whereas 17% (5 out of 30) of the retrieved Optetrak implants had no observable wear. There were no significant differences when comparing the depth of wear score between designs. The locking mechanism greatly affects the propensity for wear and should be considered when choosing a knee implant system.

  10. OVERVIEW OF THE RHIC INSERTION REGION, SEXTUPOLE, AND SNAKE POWER SUPPLY SYSTEMS

    International Nuclear Information System (INIS)

    BRUNO, D.; ENG, W.; GANETIS, G.; LAMBIASE, R.F.; SANDBERG, J.

    2001-01-01

    The Relativistic Heavy Ion Collider (RHIC) was commissioned in 1999 and 2000. RHIC requires power supplies to supply currents to highly inductive superconducting magnets. The RHIC Insertion Region (IR) contains many shunt power supplies to trim the current of different magnet elements in a large superconducting magnet circuit. There are a total of 237 Insertion Region power supplies in both RHIC rings. RHIC also requires sextupole power supplies. One sextupole power supply is connected across 12 sextupole magnets. There are a total of 24 sextupole power supplies in both rings. Snake magnets are also a part of the RHIC ring, and these snake magnets also require power supplies. There shall be a total of 24 snake power supplies in both rings. Power supply technology, connections, control systems and interfacing with the Quench Protection System will be presented

  11. Files synchronization from a large number of insertions and deletions

    Science.gov (United States)

    Ellappan, Vijayan; Kumari, Savera

    2017-11-01

    Synchronization between different versions of files is becoming a major issue that most of the applications are facing. To make the applications more efficient a economical algorithm is developed from the previously used algorithm of “File Loading Algorithm”. I am extending this algorithm in three ways: First, dealing with non-binary files, Second backup is generated for uploaded files and lastly each files are synchronized with insertions and deletions. User can reconstruct file from the former file with minimizing the error and also provides interactive communication by eliminating the frequency without any disturbance. The drawback of previous system is overcome by using synchronization, in which multiple copies of each file/record is created and stored in backup database and is efficiently restored in case of any unwanted deletion or loss of data. That is, to introduce a protocol that user B may use to reconstruct file X from file Y with suitably low probability of error. Synchronization algorithms find numerous areas of use, including data storage, file sharing, source code control systems, and cloud applications. For example, cloud storage services such as Drop box synchronize between local copies and cloud backups each time users make changes to local versions. Similarly, synchronization tools are necessary in mobile devices. Specialized synchronization algorithms are used for video and sound editing. Synchronization tools are also capable of performing data duplication.

  12. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  13. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  14. A nurse led peripherally inserted central catheter line insertion service is effective with radiological support

    International Nuclear Information System (INIS)

    Barber, Jonathan M.; Booth, Doris M.; King, Julia A.; Chakraverty, Sam

    2002-01-01

    AIM: Peripherally inserted central catheters (PICC) are increasingly used as a route of chemotherapy administration. Our aims were to assess a collaborative approach to PICC placement, with radiological support for a nurse led line insertion service in a minority of cases, and to determine whether PICC provided a safe and reliable method of chemotherapy administration. MATERIALS AND METHODS: Prospective data on 100 consecutive patients undergoing PICC placement for chemotherapy were collected. Lines were inserted by ward based nurses or under ultrasound guidance by radiologists. End points were successful completion of treatment or patient death. RESULTS: One hundred and forty-four lines were placed for 118 courses of chemotherapy. 107 (74%) were placed by nurses and 37 (26%) by radiologists. Ninety-five percent of patients completed therapy with either one or two lines. Seventy percent of lines were removed on achieving the primary end points. In two additional patients PICC could not be placed radiologically. Twelve patients were unable to complete treatment with PICC alone, nine of these required an alternative administration route. The catheter related sepsis rate was 4.9%. CONCLUSION: The majority of PICC can be successfully placed by trained nurses, reserving image guidance only for more difficult cases. PICC have an acceptable complication profile, and decrease the need for tunnelled central lines. Barber, J.M. et al. (2002)

  15. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  16. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  17. Technical note: Computer-manufactured inserts for prosthetic sockets.

    Science.gov (United States)

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  19. Insertional Polymorphisms of Endogenous Feline Leukemia Viruses

    Science.gov (United States)

    Roca, Alfred L.; Nash, William G.; Menninger, Joan C.; Murphy, William J.; O'Brien, Stephen J.

    2005-01-01

    The number, chromosomal distribution, and insertional polymorphisms of endogenous feline leukemia viruses (enFeLVs) were determined in four domestic cats (Burmese, Egyptian Mau, Persian, and nonbreed) using fluorescent in situ hybridization and radiation hybrid mapping. Twenty-nine distinct enFeLV loci were detected across 12 of the 18 autosomes. Each cat carried enFeLV at only 9 to 16 of the loci, and many loci were heterozygous for presence of the provirus. Thus, an average of 19 autosomal copies of enFeLV were present per cat diploid genome. Only five of the autosomal enFeLV sites were present in all four cats, and at only one autosomal locus, B4q15, was enFeLV present in both homologues of all four cats. A single enFeLV occurred in the X chromosome of the Burmese cat, while three to five enFeLV proviruses occurred in each Y chromosome. The X chromosome and nine autosomal enFeLV loci were telomeric, suggesting that ectopic recombination between nonhomologous subtelomeres may contribute to enFeLV distribution. Since endogenous FeLVs may affect the infectiousness or pathogenicity of exogenous FeLVs, genomic variation in enFeLVs represents a candidate for genetic influences on FeLV leukemogenesis in cats. PMID:15767400

  20. Speech Rehabilitation For 10 Alaryngeal Patients Using Tracheoesophageal Puncture And Prosthesis Insertion In Amir Alam And Imam Khomeini Hospitals 2002-2003

    Directory of Open Access Journals (Sweden)

    M.T. Khorsi Ashtiani

    2006-05-01

    Full Text Available Background and Aim: Total laryngectomy following laryngeal cancer has many sequelae , that loss of voice is the most important of them. Tracheoesophageal puncture (TEP and prosthesis insertion has evolved into the most widely used and accepted technique for vocal rehabilitation. Materials and Methods: 10 patients that underwent TEP in Amir Alam and Imam Khomeini hospitals from Feb. 2002 through Nov. 2003; were included in this study. Prosthesis insertion in 4 patients is primary and in 6 patients is secondary; and all patients are men. Results: The age of patients was between 50 to 70. 90% of patients had history of cigarette smoking and 10% of them had history of drinking alcohol. Salivary leakage was seen in 30% of patients that was improved with conservative management. Fluency of speech in 30% of patients and intelligibility of speech & voice quality in 40% of patients is good. Conclusion: We could conclude that TEP has less complication & better speech results of other vocal rehabilitation methods. Carefully selection of patients & size of prosthesis has important role in results of TEP.

  1. Total process surveillance: (TOPS)

    International Nuclear Information System (INIS)

    Millar, J.H.P.

    1992-01-01

    A Total Process Surveillance system is under development which can provide, in real-time, additional process information from a limited number of raw measurement signals. This is achieved by using a robust model based observer to generate estimates of the process' internal states. The observer utilises the analytical reduncancy among a diverse range of transducers and can thus accommodate off-normal conditions which lead to transducer loss or damage. The modular hierarchical structure of the system enables the maximum amount of information to be assimilated from the available instrument signals no matter how diverse. This structure also constitutes a data reduction path thus reducing operator cognitive overload from a large number of varying, and possibly contradictory, raw plant signals. (orig.)

  2. Total ankle joint replacement.

    Science.gov (United States)

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  4. An audit of the complications of intercostal chest drain insertion in a high volume trauma service in South Africa.

    Science.gov (United States)

    Kong, V Y; Oosthuizen, G V; Sartorius, B; Keene, C; Clarke, D L

    2014-11-01

    Intercostal chest drain (ICD) insertion is a commonly performed procedure in trauma and may be associated with significant morbidity. This was a retrospective review of ICD complications in a major trauma service in South Africa over a four-year period from January 2010 to December 2013. A total of 1,050 ICDs were inserted in 1,006 patients, of which 91% were male. The median patient age was 24 years (interquartile range [IQR]: 20-29 years). There were 962 patients with unilateral ICDs and 44 with bilateral ICDs. Seventy-five per cent (758/1,006) sustained penetrating trauma and the remaining 25% (248/1006) sustained blunt trauma. Indications for ICD insertion were: haemopneumothorax (n=338), haemothorax (n=314), simple pneumothorax (n=265), tension pneumothorax (n=79) and open pneumothorax (n=54). Overall, 203 ICDs (19%) were associated with complications: 18% (36/203) were kinked, 18% (36/203) were inserted subcutaneously, 13% (27/203) were too shallow and in 7% (14/203) there was inadequate fixation resulting in dislodgement. Four patients (2%) sustained visceral injuries and two sustained vascular injuries. Forty-one per cent (83/203) were inserted outside the 'triangle of safety' but without visceral or vascular injuries. One patient had the ICD inserted on the wrong side. Junior doctors inserted 798 ICDs (76%) while senior doctors inserted 252 (24%). Junior doctors had a significantly higher complication rate (24%) compared with senior doctors (5%) (p Conclusions ICD insertion is associated with a high rate of complications. These complications are significantly higher when junior doctors perform the procedure. A multifaceted quality improvement programme is needed to improve the situation.

  5. Amino Acid Insertion Frequencies Arising from Photoproducts Generated Using Aliphatic Diazirines

    Science.gov (United States)

    Ziemianowicz, Daniel S.; Bomgarden, Ryan; Etienne, Chris; Schriemer, David C.

    2017-10-01

    Mapping proteins with chemical reagents and mass spectrometry can generate a measure of accessible surface area, which in turn can be used to support the modeling and refinement of protein structures. Photolytically generated carbenes are a promising class of reagent for this purpose. Substituent effects appear to influence surface mapping properties, allowing for a useful measure of design control. However, to use carbene labeling data in a quantitative manner for modeling activities, we require a better understanding of their inherent amino acid reactivity, so that incorporation data can be normalized. The current study presents an analysis of the amino acid insertion frequency of aliphatic carbenes generated by the photolysis of three different diazirines: 3,3'-azibutyl-1-ammonium, 3,3'-azibutan-1-ol, and 4,4'-azipentan-1-oate. Leveraging an improved photolysis system for single-shot labeling of sub-microliter frozen samples, we used EThCD to localize insertion products in a large population of labeled peptides. Counting statistics were drawn from data-dependent LC-MS2 experiments and used to estimate the frequencies of insertion as a function of amino acid. We observed labeling of all 20 amino acids over a remarkably narrow range of insertion frequencies. However, the nature of the substituent could influence relative insertion frequencies, within a general preference for larger polar amino acids. We confirm a large (6-fold) increase in labeling yield when carbenes were photogenerated in the solid phase (77 K) relative to the liquid phase (293 K), and we suggest that carbene labeling should always be conducted in the frozen state to avoid information loss in surface mapping experiments. [Figure not available: see fulltext.

  6. Ultrasonic Guided Insertion of Central Venous Catheter in Infants ...

    African Journals Online (AJOL)

    Background/Purpose: ultrasound is licensed for application of regional blocks and insertion of vascular access. We aimed to compare ultrasonic guided (USG) and anatomical landmark technique (ALT) for insertion of central venous catheter (CVC) as regard success rate and rate of complications in infants and children.

  7. Enhanced citrate production through gene insertion in Aspergillus niger

    DEFF Research Database (Denmark)

    Jongh, Wian de; Nielsen, Jens

    2007-01-01

    The effect of inserting genes involved in the reductive branch of the tricarboxylic acid (TCA) cycle on citrate production by Aspergillus niger was evaluated. Several different genes were inserted individually and in combination, i.e. malate dehydrogenase (mdh2) from Saccharomyces cerevisiae, two...

  8. Load beam unit replaceable inserts for dry coal extrusion pumps

    Science.gov (United States)

    Saunders, Timothy; Brady, John D.

    2012-11-13

    A track assembly for a particulate material extrusion pump according to an exemplary aspect of the present disclosure includes a link assembly with a roller bearing. An insert mounted to a load beam located such that the roller bearing contacts the insert.

  9. Forward and reverse genetics: The LORE1 retrotransposon insertion mutants

    DEFF Research Database (Denmark)

    Fukai, Eigo; Malolepszy, Anna; Sandal, Niels Nørgaard

    2014-01-01

    The endogenous Lotus retrotransposon 1 (LORE1) transposes in the germ line of Lotus japonicus plants that carry an active element. This feature of LORE1 has been exploited for generation of a large non-transgenic insertion mutant population, where insertions have been annotated using next-generat...

  10. Additive Manufacturing for Highly Efficient Window Inserts CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [ORNL; Chesser, Phillip C. [ORNL; Love, Lonnie J. [ORNL

    2018-04-01

    ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were explored as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.

  11. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  12. FY 2000 Development of technologies for optimization control of reducing power loss during the service period. Report on the research and development results of the 'building total cooperation control by micro-internet technologies'; 2000 nendo kadoji denki sonshitsu sakugen saiteki seigyo gijutsu kaihatsu seika hokokusho. Micro internet gijutsu ni yoru biru total kyocho seigyo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research and development project is implemented for development of the energy-saving optimization/control system which continuously monitors/controls all of the energy-consuming appliances in a building for their optimization, and the FY 2000 results are reported. The program for the sensing technologies involves a human tracking system aided by fish-eye images and human region sensing technologies based on the neuro technologies, and introduces an animated image simulation system aided by a personal computer. The researches on the building total cooperation control involve establishment of the system designs for controlling heat sources, based on the thermal loads predicted by the information network system. The researches on the micro-internet technologies involve development of the prototype unit which collects information from indoor environment sensors (e.g., for room temperature, luminous intensity and CO2 concentration), and interface devices which collect information from the sub-systems, e.g., air conditioners and heat sources. These systems are completed. The demonstration and assessment program involves designs of the instrumentation systems and network environments. The designs are completed, and various sensors and monitors are installed. (NEDO)

  13. FY 2000 Development of technologies for optimization control of reducing power loss during the service period. Report on the research and development results of the 'building total cooperation control by micro-internet technologies'; 2000 nendo kadoji denki sonshitsu sakugen saiteki seigyo gijutsu kaihatsu seika hokokusho. Micro internet gijutsu ni yoru biru total kyocho seigyo

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The research and development project is implemented for development of the energy-saving optimization/control system which continuously monitors/controls all of the energy-consuming appliances in a building for their optimization, and the FY 2000 results are reported. The program for the sensing technologies involves a human tracking system aided by fish-eye images and human region sensing technologies based on the neuro technologies, and introduces an animated image simulation system aided by a personal computer. The researches on the building total cooperation control involve establishment of the system designs for controlling heat sources, based on the thermal loads predicted by the information network system. The researches on the micro-internet technologies involve development of the prototype unit which collects information from indoor environment sensors (e.g., for room temperature, luminous intensity and CO2 concentration), and interface devices which collect information from the sub-systems, e.g., air conditioners and heat sources. These systems are completed. The demonstration and assessment program involves designs of the instrumentation systems and network environments. The designs are completed, and various sensors and monitors are installed. (NEDO)

  14. Low voltage aluminium anodes. Optimization of the insert-anode bond

    Energy Technology Data Exchange (ETDEWEB)

    Le Guyader, Herve; Debout, Valerie; Grolleau, Anne-Marie [DCN Cherbourg, Departement 2EI, Place Bruat, BP 440, 50104 Cherbourg-Octeville (France); Pautasso, Jean-Pierre [DGA/CTA 16 bis, avenue Prieur de la Cote D' Or, 94 114 Arcueil Cedex (France)

    2004-07-01

    Zinc or Al/Zn/In sacrificial anodes are widely used to protect submerged marine structures from corrosion. Their Open Circuit Potential range from - 1 V vs. Ag/AgCl for Zn anodes to -1.1 V vs. Ag/AgCl for Al/Zn/In. These potentials are sufficiently electronegative as to reduce the threshold for stress corrosion cracking and/or hydrogen embrittlement, KISCC, especially in the presence of high strength alloys. In the 90's, an extensive research programme was initiated by DGA/DCN to implement a new low voltage material. Laboratory and full scale marine tests performed on industrial castings, as previously reported, led to the development of a new patented Al- 0.1%Ga alloy having a working potential of - 0.80 to - 0.83 V vs. Ag/AgCl. This alloy was also evaluated at full scale at the Naval Research Laboratory anode qualification site in Key West, Fl, and gave satisfactory results. Around 500 cylindrical AlGa anodes were then installed on a submerged marine structure replacing the classical zinc anode. A first inspection, carried out after a few months of service, showed that some of the anodes had not operated as expected, which led to further investigations. The examinations performed indicated that the problem was due to a bad metallurgical compatibility between the insert and the sacrificial materials inducing a poor bond between the anode and the plain rod insert. Progressive loss of contact between the anode and the structure to be protected was then induced by penetration of sea water and corrosion at the anode-insert interface. This phenomenon was aggravated by seawater pressure. Additional studies were therefore launched with two aims: (1) find temporary remedies for the anodes already installed on the structure; (2) correct the anode original design and/or manufacturing process to achieve the maximum performance on new anodes lots. This paper describes the various solutions investigated to improve the insert-anode bond: design of the anode, rugosity and

  15. Primary break with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Cordelle, F.; Champ, M.; Pochard, R.

    1988-10-01

    The probabilitic safety assessment of a 900 MW plant has displayed the potential importance, with regard to the risk, of intermediate primary breaks with failure of the high pressure safety injection system. The probability of such sequence is about 10 -6 /plant X year. Therefore, it is necessary to establish: - if this sequence can lead to core melt down, - if clad ruptures can occur. This event must be taken into account to determine the repair time of contaminated systems. For these studies, a three inch equivalent diameter break is considerd, as this is the most sensitive in its category with regard to these phenomena. In addition to the above objectives, the purpose of these studies is to evaluate the sensitivity of the results to the following parameters: - the time limit at which the operator starts cooling down the plant via the steam generators. Two calculations have been made with the RELAP code (1 and 2) and two with the CATHARE code (3 and 4) - the pump trip time. Four calculations have been made with the CATHARE code (5, 6, 7 and 8). In the case of failure of only one high pressure safety injection file, 6 calculations have been made with the CATHARE code, concerning the influence of pump trip time (9, 10, 11, 12, 13 and 14)

  16. A Sudden Total Loss of Vision After Routine Cataract Surgery ...

    African Journals Online (AJOL)

    We share our experience of a 50-year-old controlled hypertensive woman who had routine cataract surgery in her left eye. She was given retrobulbar Xylocaine with adrenalin and postoperative gentamycin. She subsequently became blind in the operated eye after developing macular infarction by the first day post ...

  17. 24 CFR 266.648 - Items included in total loss.

    Science.gov (United States)

    2010-04-01

    ... AUTHORITIES HOUSING FINANCE AGENCY RISK-SHARING PROGRAM FOR INSURED AFFORDABLE MULTIFAMILY PROJECT LOANS... payments that the HFA made from its own funds and not from project income for: (1) Taxes, special... from project income for: (1) Preservation, operation and maintenance of the property; (2) Repairs...

  18. 24 CFR 266.650 - Items deducted from total loss.

    Science.gov (United States)

    2010-04-01

    ... not limited to returned premiums from canceled insurance policies, interest on investments of reserve...) Any net income from the mortgaged property/project that the HFA received after the date of default. (e...

  19. Total perinatally related losses at Tygerberg Hospital – a ...

    African Journals Online (AJOL)

    Objective. To determine the leading causes of perinatal deaths and to evaluate any changes, with the inclusion of placental histology. Method. At perinatal mortality meetings, primary and final causes of death were assigned for the period 1 July 2006 - 30 June 2007. All singleton babies born to women residing in the ...

  20. Losses in Ferroelectric Materials

    Science.gov (United States)

    Liu, Gang; Zhang, Shujun; Jiang, Wenhua; Cao, Wenwu

    2015-01-01

    loss mechanisms are discussed in terms of compositions, crystal structures, temperature, domain configurations, domain sizes and grain boundaries. The intrinsic and extrinsic contributions to the total energy dissipation are quantified. In domain engineered ferroelectric single crystals and ceramics, polarization rotations, domain wall motions and mechanical wave scatterings at grain boundaries are believed to control the mechanical quality factors of piezoelectric resonators. We show that a thorough understanding on the kinetic processes is critical in analyzing energy loss behavior and other time-dependent properties in ferroelectric materials. At the end of the review, existing challenges in the study and control of losses in ferroelectric materials are analyzed, and future perspective in resolving these issues is discussed. PMID:25814784

  1. Losses in Ferroelectric Materials.

    Science.gov (United States)

    Liu, Gang; Zhang, Shujun; Jiang, Wenhua; Cao, Wenwu

    2015-03-01

    loss mechanisms are discussed in terms of compositions, crystal structures, temperature, domain configurations, domain sizes and grain boundaries. The intrinsic and extrinsic contributions to the total energy dissipation are quantified. In domain engineered ferroelectric single crystals and ceramics, polarization rotations, domain wall motions and mechanical wave scatterings at grain boundaries are believed to control the mechanical quality factors of piezoelectric resonators. We show that a thorough understanding on the kinetic processes is critical in analyzing energy loss behavior and other time-dependent properties in ferroelectric materials. At the end of the review, existing challenges in the study and control of losses in ferroelectric materials are analyzed, and future perspective in resolving these issues is discussed.

  2. New developments on the generation of arbitrary polarized radiation from insertion devices

    International Nuclear Information System (INIS)

    Elleaume, P.

    1991-01-01

    The complete description of the polarization of a beam of radiation is described in terms of the total energy and three polarization rates. The polarization characteristics from conventional undulators and wigglers is recalled. A presentation is made of some new insertion devices that were proposed and/or built to generate circular polarization and more generally to improve the control of polarization. They are the asymmetric and elliptical wigglers and the helical and crossed undulators

  3. Survival rates and bone loss after immediate loading of implants in fresh extraction sockets (single gaps). A clinical prospective study with 4 year follow-up

    Science.gov (United States)

    Wojtovicz, Eduardo; España-Lopez, Antonio; Jimenez-Guerra, Alvaro; Monsalve-Guil, Loreto; Ortiz-Garcia, Ivan; Serrera-Figallo, Maria-Angeles

    2018-01-01

    Background The aim of this prospective study was to report the outcome of treatment with implants inserted after tooth extraction and immediately loaded. Material and Methods Fifty-six patients with single tooth loss were treated with 116 IPX Galimplant® implants with internal connections and a sandblasted, acid-etched surface. All implants were placed after tooth extraction using a flapless approach without bone regeneration, and they were then immediately loaded with cemented acrylic prostheses. After a period of three months, definitive cemented ceramic prostheses were placed. Patients were examined throughout a total of 4 years of follow-up. Marginal bone loss and survival rates were evaluated using digital periapical radiographs, taking into account clinical variables such as age, gender, smoking, history of periodontitis, etiology of extraction, placement site, diameter, and implant length. The Mann-Whitney U and Kruskal-Wallis non-parametric tests were used to compare differences between subgroups created based on the different clinical variables identified. Results Clinical results indicate an implant survival and success rate of 97.4%. Three implants were lost. Of the 116 immediate acrylic single crowns initially placed, 113 were replaced with definitive ceramic crowns after 3 months. A total of 77.8% of implants were inserted in the maxilla, while 22.2% were inserted in the mandible. No further complications were reported after the follow-up period (4 years). The mean marginal bone loss was 0.67 mm ± 0.40 mm. No differences were found among the subgroups of study patients. Conclusions This study indicates that dental implants that are inserted after tooth extraction and immediately loaded may constitute a successful and predictable alternative implant treatment. Key words:Dental implants, post-extraction implants, fresh sockets, immediate loading, immediate prostheses, implant dentistry. PMID:29476669

  4. Validation of an improved abnormality insertion method for medical image perception investigations

    Science.gov (United States)

    Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.

    2009-02-01

    The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.

  5. The Effect of Suture Anchor Insertion Angle on Calcaneus Pullout Strength: Challenging the Deadman's Angle.

    Science.gov (United States)

    Weiss, William M; Saucedo, Ramon P; Robinson, John D; Lo, Chung-Chieh Jason; Morris, Randal P; Panchbhavi, Vinod K

    2017-10-01

    Refractory cases of Achilles tendinopathy amenable to surgery may include reattachment of the tendon using suture anchors. However, there is paucity of information describing the optimal insertion angle to maximize the tendon footprint and anchor stability in the calcaneus. The purpose of this investigation is to compare the fixation strength of suture anchors inserted at 90° and 45° (the Deadman's angle) relative to the primary compressive trabeculae of the calcaneus. A total of 12 matched pairs of adult cadaveric calcanei were excised and potted to approximate their alignment in vivo. Each pair was implanted with 5.5-mm bioabsorbable suture anchors placed either perpendicular (90°) or oblique (45°) to the primary compressive trabeculae. A tensile load was applied until failure of anchor fixation. Differences in failure load and stiffness between anchor fixation angles were determined by paired t-tests. No significant differences were detected between perpendicular and oblique suture anchor insertion relative to primary compressive trabeculae in terms of load to failure or stiffness. This investigation suggests that the fixation strength of suture anchors inserted perpendicular to the primary compression trabeculae and at the Deadman's angle are possibly comparable. Biomechanical comparison study.

  6. Risk Factors Related to Peripherally Inserted Central Venous Catheter Nonselective Removal in Neonates

    Directory of Open Access Journals (Sweden)

    Xiaohe Yu

    2018-01-01

    Full Text Available We aimed to investigate the incidence and risk factors associated with nonselective removal of peripherally inserted central venous catheter (PICC in neonates. In this prospective cohort study, neonates who underwent PICC placement at neonatal intensive care units (NICUs in China from October 2012 to November 2015 were included. The patient demographics, catheter characteristics, catheter duration, PICC insertion site, indication for PICC insertion, infuscate composition, PICC tip location, and catheter complications were recorded in a computerized database. Risk factors for nonselective removal were analyzed. A total of 497 PICCs were placed in 496 neonates. Nonselective removal occurred in 9.3% of PICCs during 10,540 catheter-days (4.6 nonselective removals per 1,000 catheter-days. These included occlusion (3%, infection (1.4%, leakage (2.0%, phlebitis (0.6%, displacement (1%, pleural effusion(0.6%, and breaks (0.6%. Noncentral tip position was independently associated with an increased risk of nonselective removal (odds ratio 2.621; 95% confidence interval, 1.258-5.461 after adjusting for gestational age, sex, birth weight, and PICC dwell time. No significant differences in the rate of complications occurred between silastic and polyurethane PICC or different insertion sites. Noncentral PICC tip position was the only independent risk factor for nonselective removal of PICC.

  7. [Sacroiliac joint injury treated with oblique insertion at anatomical points: a randomized controlled trial].

    Science.gov (United States)

    Kuang, Jiayi; Li, Yuxuan; He, Yufeng; Gan, Lin; Wang, Aiming; Chen, Yanhua; Li, Xiaoting; Guo, Lin; Tang, Rongjun

    2016-04-01

    To compare the effects of oblique insertion at anatomical points and conventional acupuncture for sacroiliac joint injury. Eighty patients were randomly divided into an observation group and a control group, 40 cases in each one. In the observation group, oblique insertion therapy at anatomical points was used, and the 9 points of equal division (anatomical points) marked by palpating the anatomical symbol were treated as the insertion acupoints. In the control group, conventional acupuncture was applied, and perpendicular insertion was adopted at Huantiao (GB 30), Zhibian (BL 54) and Weizhong (BL 40), etc. In the two groups, the! treatment was given once a day and 5 times per week. Ten treatments were made into one course and two courses were required. The clinical effects, the changes of visual analogue scale (VAS) and Oswestry dysfunctional index. (ODI) before and after treatment were observed in the two groups. The total effective rate of the observation group was 90.0% (36/40), which was better than 72.5% (29/40) of the control group (P sacroiliac joint injury is superior to that of conventional acupuncture, which can effectively relieve pain and improve the disfunction.

  8. Normal Conducting Separation Dipoles For The Lhc Beam Cleaning Insertions

    CERN Document Server

    Petrov, V; de Rijk, G; Gerard, D; Hans, O; Kalbreier, Willi; Kiselev, O; Protopopov, I V; Pupkov, Yu; Ramberger, S; Ruvinsky, E; Sukhanov, A

    2004-01-01

    In the Large Hadron Collider (LHC), two straight sections, IR3 and IR7, will be dedicated to beam cleaning [1]. These cleaning insertions will be equipped with normal conducting magnets. MBW magnets are dipole magnets used to increase the separation of the two beams. They have a core length of 3.4 m and a gap height of 52 mm and will operate at a magnetic field ranging from 0.09 T to 1.53 T. Limitations on the dimensions and total weight of the magnet resulted in a special design with a common yoke for the two beams. The orbits of the two beams will be separated horizontally by a distance between 194 mm and 224 mm in the gap of the magnet. The magnet was designed in collaboration between CERN and BINP. The report presents the main design issues and results of the pre-series acceptance tests including mechanical, electrical and magnetic field measurements. Index terms - LHC, normal conducting magnet, twin aperture design, separation dipole

  9. Overview of the ATLAS Insertable B-Layer (IBL) Project

    CERN Document Server

    Pohl, D-L; The ATLAS collaboration

    2013-01-01

    The upgrades for the ATLAS Pixel Detector will be staged in preparation for high luminosity LHC. The first upgrade for the Pixel Detector will be the construction of a new pixel layer which is currently under construction and will be installed during the first shutdown of the LHC machine, in 2013-14. The new detector, called the Insertable B-layer (IBL), will be installed between the existing Pixel Detector and a new, smaller radius beam-pipe at a radius of 3.3 cm. The IBL required the development of several new technologies to cope with increased radiation and pixel occupancy and also to improve the physics performance through reduction of the pixel size and a more stringent material budget. Two different silicon sensor technologies, planar n-in-n and 3D, will be used, connected with the new generation 130nm IBM CMOS FE-I4 readout chip via solder bump-bonds. 32 FEs with sensors are glued to a light weight carbon-carbon structure which incorporates a titanium cooling tube for a CO2 cooling system. In total th...

  10. Independents' group posts loss

    International Nuclear Information System (INIS)

    Sanders, V.; Price, R.B.

    1992-01-01

    Low oil gas prices and special charges caused the group of 50 U.S. independent producers Oil and Gas Journal tracks to post a combined loss in first half 1992. The group logged a net loss of $53 million in the first half compared with net earnings of $354 million in first half 1991, when higher oil prices during the Persian Gulf crisis buoyed earnings in spite of crude oil and natural gas production declines. The combined loss in the first half follows a 45% drop in the group's earnings in 1991 and compares with the OGJ group of integrated oil companies whose first half 1992 income fell 47% from the prior year. Special charges, generally related to asset writedowns, accounted for most of the almost $560 million in losses posted by about the third of the group. Nerco Oil and Gas Inc., Vancouver, Wash., alone accounted for almost half that total with charges related to an asset writedown of $238 million in the first quarter. Despite the poor first half performance, the outlook is bright for sharply improved group earnings in the second half, assuming reasonably healthy oil and gas prices and increased production resulting from acquisitions and in response to those prices

  11. Hysteroscopic Essure Inserts for Permanent Contraception: Extended Follow-Up Results of a Phase III Multicenter International Study.

    Science.gov (United States)

    Chudnoff, Scott G; Nichols, John E; Levie, Mark

    2015-01-01

    To describe safety, tolerability, and effectiveness results through 5 years of follow-up of a Phase III trial with Essure inserts. Multicenter, nonrandomized, single-arm international study (Canadian Task Force classification II-3). Thirteen clinical study centers in the United States, Europe, and Australia. A total of 518 previously fertile women seeking permanent contraception. The objective of the hysteroscopic sterilization procedure was bilateral Essure insert placement (ESS205 model) and tubal occlusion. Women with satisfactory device location and tube occlusion (based on modified hysterosalpingography [HSG]) were instructed to discontinue alternative contraception and to rely on Essure inserts for permanent contraception. The primary endpoint for the Phase III study was the rate of pregnancies occurring during the first year of relying (i.e., HSG-confirmed occlusion) on the Essure inserts for permanent contraception (i.e., 12 months after HSG). For the full 5 years of follow-up (5 years total of relying on the Essure inserts for contraception), the endpoints of interest were safety, prevention of pregnancy, and satisfaction. No pregnancies were reported among women relying on the Essure inserts who completed the full 5 years of follow-up. As of December 5, 2007, 449 women with successful bilateral placement relying on the Essure inserts contributed a total 24 942 woman-months of follow-up for assessing effectiveness. Overall, the Essure inserts were generally well tolerated, with participant comfort rated as "good" to "excellent" by 99% of women (382 of 385) after 5 years of use. Similarly, overall satisfaction was rated as "somewhat" to "very satisfied" by 98% of women (376 of 384) after 5 years of use. The majority of adverse events reported during the 5 years of follow-up were rated as either "mild" or "moderate" in severity. Three severe events (abdominal pain with very heavy periods and irregular menstrual bleeding) were reported in 2 subjects during

  12. Racetrack resonator as a loss measurement platform for photonic components.

    Science.gov (United States)

    Jones, Adam M; DeRose, Christopher T; Lentine, Anthony L; Starbuck, Andrew; Pomerene, Andrew T S; Norwood, Robert A

    2015-11-02

    This work represents the first complete analysis of the use of a racetrack resonator to measure the insertion loss of efficient, compact photonic components. Beginning with an in-depth analysis of potential error sources and a discussion of the calibration procedure, the technique is used to estimate the insertion loss of waveguide width tapers of varying geometry with a resulting 95% confidence interval of 0.007 dB. The work concludes with a performance comparison of the analyzed tapers with results presented for four taper profiles and three taper lengths.

  13. Ultra Low Loss Optical Fiber Cable Assemblies. Volume 2.

    Science.gov (United States)

    1983-06-07

    AND CABLE ASSEMBLY TEST PLAN I Part 1: CABLE TEST PLAN for U. S. ARMY CORADCOM Fort Monmouth, New Jersey 9~Contract # DA -A B07-78-C-29ZZ * Prepared by...VICES$ 1TEST OArg sMATED UTZx ccwITE I INSERTION LOSS £P40,,T PdA. "AT1 NO. ’we Uva ITS R.H. REQUECZ=ENT: The insertion loss of a mated =ai.r of...16(m separation between the rear of the con- nectar and the first turn on the mandrel. After which the plug and receptacle were mated, the mounting

  14. Comparison of Laparoscopic versus Open Surgery after Insertion of Self-Expandable Metallic Stents in Acute Malignant Colorectal Obstruction: A Case-Matched Study

    Directory of Open Access Journals (Sweden)

    Chotirot Angkurawaranon

    2017-03-01

    Full Text Available Background: Self-expanding metallic stents (SEMS have been acknowledged in management of acute colorectal obstruction. The surgical approach after SEMS insertion varies from open approach to laparoscopic-assisted approach. The primary objective of this study was to compare the outcomes of laparoscopic approach and open approach after SEMS insertion. Methods: From January 2007 to December 2010, cross-sectional medical records reviewed a total of 76 patients who underwent colorectal stenting with SEMS. Patients and tumor characteristics, complications, morbidity and mortality were obtained. Results: Forty-three patients underwent SEMS placement as a bridge to surgery. Laparoscopic-assisted surgery (LS was performed in 24 patients (55.8%, and open surgery (OS was performed in 19 patients (44.2%. All clinicopathological parameters were matched. The technical success of SEMS was found in 42 patients (97.7%, and the clinical stent success was 100%. LS had a higher chance of primary anastomosis than OS (p=0.012; Odd ratio 2.717; 95%CI: 1.79-4.012. LS had a lower permanent ostomy rate (p=0.031; Odd ratio 0.385; 95%CI: 0.259-0.572 and lower estimated blood loss (p=0.024; Odd ratio 0.23; 95%CI: 0.006-0.086. The post-operative complications, mortality rate, recurrence rate, disease free status, and overall survival rates between the two groups were non-significant. Conclusion: Colonic stent is an effective treatment of acute malignant colonic obstruction. The authors suggest the advantage of laparoscopic approach resection after colonic stenting results in a higher primary anastomosis rate, and lower blood loss than open surgery.

  15. Dental implants inserted in fresh extraction sockets versus healed sites: a systematic review and meta-analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-01-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection and marginal bone loss for the insertion of dental implants in fresh extraction sockets compared to the insertion in healed sites, against the alternative hypothesis of a difference. Main search terms used in combination: dental implant, oral implant, resh extraction socket, immediate placement, immediate insertion, immediate implant. An electronic search was undertaken in July/2014, in PubMed, Web of Science, Cochrane Oral Health Group Trials Register plus hand-searching. Eligibility criteria included clinical human studies, either randomized or not. The search strategy resulted in 73 publications, with 8,241 implants inserted in sockets (330 failures, 4.00%), and 19,410 in healed sites (599 failures, 3.09%). It is suggested that the insertion of implants in fresh extraction sockets affects the failure rates (RR 1.58, 95% CI 1.27-1.95, P<0.0001). The difference was not statistically significant when studies evaluating implants inserted in maxillae or in mandibles were pooled, or when the studies using implants to rehabilitate patients with full-arch prostheses were pooled; however, it was significant for the studies that rehabilitated patients with implant-supported single crowns and for the controlled studies. There was no apparent significant effect on the occurrence of postoperative infection or on the magnitude of marginal bone loss. The results should be interpreted with caution due to the potential for biases and to the presence of uncontrolled confounding factors in the included studies, most of them not randomized. The question whether immediate implants are more at risk for failure than implants placed in mature bone has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine techniques and eliminate unnecessary procedures. This would form a basis

  16. Weight loss and weight loss maintenance efficacy of a novel weight loss program: The retrospective RNPC® cohort

    DEFF Research Database (Denmark)

    Thorning, Tanja Kongerslev; Fabre, Odile; Legrand, Rémy

    2018-01-01

    or obese patients treated in 54 RNPC® weight loss clinics in France. Results: A total of 10,809 (89%) patients completed the initial weight loss phase and 2996 (25%) completed the full program. Median weight loss percentage was 10.7% (Interquartile range [IQR]: 5.8; 16.5) after a median of 105 days (IQR...

  17. Living with vision loss

    Science.gov (United States)

    Diabetes - vision loss; Retinopathy - vision loss; Low vision; Blindness - vision loss ... of visual aids. Some options include: Magnifiers High power reading glasses Devices that make it easier to ...

  18. Automatic needle insertion diminishes pain during growth hormone injection

    DEFF Research Database (Denmark)

    Main, K M; Jørgensen, J T; Hertel, N T

    1995-01-01

    prototype pens for GH administration, providing either manual or automatic sc needle insertion, using a combined visual analogue/facial scale and a five-item scale in 18 children. With the automatic pen there was a significantly lower maximum pain score compared with the manual pen (median 28.5 versus 52.......0 mm) as well as a lower mean pain score (mean 13.7 versus 23.5 mm). The five-item scale revealed that automatic needle insertion was significantly less painful than manual insertion and 13 patients chose to continue treatment with the automatic pen. In conclusion, pain during GH injection can...

  19. Lithium insertion mechanism in SnS2

    International Nuclear Information System (INIS)

    Lefebvre-Devos, I.; Olivier-Fourcade, J.; Jumas, J.C.; Lavela, P.

    2000-01-01

    We study lithium insertion in SnS 2 by means of 119 Sn Moessbauer spectroscopy, x-ray absorption spectroscopy at Sn L I,III , and S K edges, and theoretical electronic structures (calculated in the density-functional theory framework). An insertion mechanism is derived according to the Li amount. It shows the influence of the SnS 2 -layered structure on the Sn reduction, particularly the possibility of an intermediate oxidation state between Sn IV and Sn II , which is not observed during Li insertion in three-dimensional sulfides

  20. Effect of insertion torque on titanium implant osseointegration: an animal experimental study.

    Science.gov (United States)

    Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen

    2015-02-01

    To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P torque led to an increased BA/TA after 4 week of healing (P torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Doppler color flow analysis of the uterine arteries before and after intrauterine device insertion: a prospective study.

    Science.gov (United States)

    de Souza, Marco Aurélio Martins; Geber, Selmo

    2006-02-01

    An intrauterine device (IUD) is one of the most frequently used methods of birth control around the world. Although a relationship between its use and menstrual disorders has been well documented, only a few studies have tried to show whether there are any vascular modifications. The aim of our study was to evaluate the influence of an IUD on uterine artery blood flow using Doppler assessment. A total of 100 patients selected for IUD use were prospectively evaluated with Doppler analysis before and 30 days after insertion. The resistive index (RI) and pulsatility index (PI) were used to evaluate uterine artery vascular resistance. Patients were allocated in 2 groups according to whether they were (group 2) or were not (group 1) lactating. The PI and RI of the patients in groups 1 and 2 before and after IUD insertion were not statistically significantly different (P = .298 and .23). When we compared uterine artery blood flow indices before and after IUD insertion for groups 1 and 2 separately, we observed in group 1 that the mean +/- SD PI values were 2.45 +/- 0.62 and 2.55 +/- 0.55 (P = .38) and the RI values were 0.87 +/- 0.08 and 0.87 +/- 0.06 (P = .88) before and after IUD insertion, respectively. In group 2, the PI values were 2.31 +/- 0.55 and 2.37 +/- 0.69 (P = .68) and the RI values were 0.85 +/- 0.07 and 0.86 +/- 0.07 (P = .44) before and after IUD insertion. Finally, we used the mean blood flow indices of the uterine arteries of all patients to compare the effect of IUD insertion. Results were also not statistically significant when we compared PI and RI before and after IUD insertion. The presence of an IUD does not interfere with the vascular resistance of the uterine arteries that can be shown by Doppler flow assessments 1 month after insertion.

  2. Factors affecting colonoscope insertion time in patients with or without a colostomy after left-sided colorectal resection.

    Science.gov (United States)

    Jang, Hui Won; Kim, Yoon Nam; Nam, Chung Mo; Lee, Hyun Jung; Park, Soo Jung; Hong, Sung Pil; Kim, Tae Il; Kim, Won Ho; Cheon, Jae Hee

    2012-12-01

    We examined whether the insertion time for colonoscopies performed after left-sided resection was different in patients with a colostomy from that in patients without a colostomy and identified factors that could impact colonoscopy performance. We included consecutive patients who underwent colonoscopy between July 2005 and March 2011 after left-sided colorectal resection for colorectal cancer. We classified surgical methods according to the presence or absence of a colostomy and evaluated colonoscope insertion time retrospectively. Furthermore, we analyzed factors that might affect insertion time. A total of 1,041 patients underwent colonoscopy after left-sided colorectal resection during the study period. The colonoscopy completion rate was 98.6 %, and the mean insertion time was 6.1 ± 4.6 min (median 4.7 min, range 0.3-35.8 min). A shorter resection length of colon, the presence of a colostomy, and a lower endoscopist case volume were found to be independent factors associated with prolonged insertion time in patients with left-sided colorectal resection. Among experienced colonoscopists, no colonoscopy-associated or clinical factors were found to affect insertion time. However, a shorter resection length of colon, the presence of a colostomy, and poor bowel preparation were associated with prolonged insertion time among inexperienced endoscopists. We identified three factors that affect colonoscope insertion time after left-sided colorectal resection, including the presence of a colostomy. Inexperienced endoscopists were much more affected by the presence of a colostomy after left-sided colorectal resection. These findings have implications for the practice and teaching of colonoscopy after left-sided colorectal resection.

  3. Use of a mid-scala and a lateral wall electrode in children: insertion depth and hearing preservation.

    Science.gov (United States)

    Benghalem, Abdelhamid; Gazibegovic, Dzemal; Saadi, Fatima; Tazi-Chaoui, Zakia

    2017-01-01

    Atraumatic insertion of the HiFocus TM Mid-Scala (HFMS) electrode via the round window was successfully achieved in seven children. Residual hearing 6 months post-operatively was preserved to within 10 dB HL of the pre-operative audiogram at 500 Hz for six children, indicating minimal initial insertion trauma to the cochlea. The objectives were to document the clinical experience and evaluate differences between HFMS and HiFocus TM 1j (HF1j) by means of insertion depth and hearing preservation results. Nineteen children were prospectively recruited and consecutively implanted with the HF1j electrode (n = 12) or the HFMS electrode (n = 7) via the round window. Average median angular insertion depths and the amount of residual hearing preserved at 6 months post-operatively were compared between the two electrode groups. The median angular insertion depth for the HF1j was 439° and for the HFMS 435°. Preservation of residual hearing at 500 Hz was assessed in seven HFMS subjects and 11 HF1j subjects. Based on the Skarzynski formula, three out of seven subjects (42%) in the HFMS group had their residual hearing completely preserved at 500 Hz. In the control group, no subjects had complete hearing preservation and five subjects had a complete loss of residual hearing.

  4. Proposal for the award of a contract for the supply of superconducting cables for the LHC low-current insertion (mqm) and wide-aperture insertion (mqy) quadrupoles

    CERN Document Server

    1999-01-01

    This document concerns the award of a contract for the supply of the superconducting cables for the LHC low-current insertion (MQM) and wide-aperture insertion (MQY) quadrupoles. A call for tenders (IT-2631/LHC/LHC) was sent to four firms in four Member States, three firms in Japan and two firms in the USA on 3 June 1999. By the closing date, CERN had received seven tenders. The Finance Committee is invited to agree to the negotiation of a contract with the firm VACUUMSCHMELZE (DE) for the supply of all superconducting cables for the LHC MQM and MQY quadrupoles for a total net price of 3 240 257 euros, subject to revision after 31 December 2000, with an option to procure additional cables representing 10% of the initial quantity for a total net price of 324 026 euros, bringing the total to an amount of 3 564 283 euros, subject to revision after 31 December 2000. At the exchange rate given in the tender, these amounts correspond to 5 192 720 Swiss francs, 519 272 Swiss francs and 5 711 992 Swiss francs respect...

  5. A Novel Insertion Variant of CRYGD Is Associated with Congenital Nuclear Cataract in a Chinese Family.

    Science.gov (United States)

    Zhuang, Xiaotong; Wang, Lianqing; Song, Zixun; Xiao, Wei

    2015-01-01

    To investigate a novel insertion variant of CRYGD identified in a Chinese family with nuclear congenital cataract. A Chinese family with congenital nuclear cataract was recruited for the mutational screening of candidate genes by direct sequencing. Recombinant N-terminal Myc tagged wildtype or mutant CRYGD was expressed in HEK293T cells. The expression pattern, protein solubility and subcellular distribution were analyzed by western blotting and immunofluorescence. A novel insertion variant, c.451_452insGACT, in CRYGD was identified in the patients. It causes a frameshift and a premature termination of the polypeptide to become Y151*. A significantly reduced solubility was observed for this mutant. Unlike wildtype CRYGD, which existed mainly in the cytoplasm, Y151* was mis-located in the nucleus. We have identified a novel mutation, c.451_452insGACT, in CRYGD, which is associated with nuclear cataract. This is the first insertion mutation of CRYGD found to cause autosomal dominant congenital cataract. The mutant protein, with loss of solubility and localization to the nucleus, is hypothesized to be the major cause of cataract in these patients.

  6. Laparoscopic versus open peritoneal dialysis catheter insertion, the LOCI-trial: a study protocol

    Directory of Open Access Journals (Sweden)

    Hagen Sander M

    2011-12-01

    Full Text Available Abstract Background Peritoneal dialysis (PD is an effective treatment for end-stage renal disease. It allows patients more freedom to perform daily activities compared to haemodialysis. Key to successful PD is the presence of a well-functioning dialysis catheter. Several complications, such as in- and outflow obstruction, peritonitis, exit-site infections, leakage and migration, can lead to catheter removal and loss of peritoneal access. Currently, different surgical techniques are in practice for PD-catheter placement. The type of insertion technique used may greatly influence the occurrence of complications. In the literature, up to 35% catheter failure has been described when using the open technique and only 13% for the laparoscopic technique. However, a well-designed randomized controlled trial is lacking. Methods/Design The LOCI-trial is a multi-center randomized controlled, single-blind trial (pilot. The study compares the laparoscopic with the open technique for PD catheter insertion. The primary objective is to determine the optimum placement technique in order to minimize the incidence of catheter malfunction at 6 weeks postoperatively. Secondary objectives are to determine the best approach to optimize catheter function and to study the quality of life at 6 months postoperatively comparing the two operative techniques. Discussion This study will generate evidence on any benefits of laparoscopic versus open PD catheter insertion. Trial registration Dutch Trial Register NTR2878

  7. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  8. Fluoroscopy-guided insertion of nasojejunal tubes in children - setting local diagnostic reference levels

    International Nuclear Information System (INIS)

    Vitta, Lavanya; Raghavan, Ashok; Sprigg, Alan; Morrell, Rachel

    2009-01-01

    Little is known about the radiation burden from fluoroscopy-guided insertions of nasojejunal tubes (NJTs) in children. There are no recommended or published standards of diagnostic reference levels (DRLs) available. To establish reference dose area product (DAP) levels for the fluoroscopy-guided insertion of nasojejunal tubes as a basis for setting DRLs for children. In addition, we wanted to assess our local practice and determine the success and complication rates associated with this procedure. Children who had NJT insertion procedures were identified retrospectively from the fluoroscopy database. The age of the child at the time of the procedure, DAP, screening time, outcome of the procedure, and any complications were recorded for each procedure. As the radiation dose depends on the size of the child, the children were assigned to three different age groups. The sample size, mean, median and third-quartile DAPs were calculated for each group. The third-quartile values were used to establish the DRLs. Of 186 procedures performed, 172 were successful on the first attempt. These were performed in a total of 43 children with 60% having multiple insertions over time. The third-quartile DAPs were as follows for each age group: 0-12 months, 2.6 cGy cm 2 ; 1-7 years, 2.45 cGy cm 2 ; >8 years, 14.6 cGy cm 2 . High DAP readings were obtained in the 0-12 months (n = 4) and >8 years (n = 2) age groups. No immediate complications were recorded. Fluoroscopy-guided insertion of NJTs is a highly successful procedure in a selected population of children and is associated with a low complication rate. The radiation dose per procedure is relatively low. (orig.)

  9. Image-guided chemoport insertion by interventional radiologists: A single-center experience on periprocedural complications

    International Nuclear Information System (INIS)

    Yaacob, Yazmin; Nguyen, Dang V; Mohamed, Zahiah; Ralib, A Razali A; Zakaria, Rozman; Muda, Sobri

    2013-01-01

    To report our early experience in image-guided chemoport insertions by interventional radiologists. This was a cross-sectional study conducted in a tertiary center with 161 chemoport insertions done from June 2008 to June 2010. The chemoports were inserted either at the angiography suite or at the mobile operation theater unit. Ninety percent of the chemoports had right internal jugular vein (IJV) as the entry site. Other entry sites included the left IJV, subclavian veins and the inferior vena cava. Immediate and early complications were recorded. All insertions were performed under image guidance with the aid of ultrasound and fluoroscopy. The technical success rate was 99.4%. In terms of immediate complications, there were only two cases of arterial puncture that resolved with local compression. No pneumothorax or air embolism was documented. Twenty-six early complications were recorded. The most common early complication was catheter blockage (12/161; 7.4%), followed by catheter-related infection (9/161; 5.6%). Other complications were catheter malposition, venous thrombosis and catheter dislodgement or leak. A total of 11 (6.8%) chemoports had to be removed within 30 days; most of them were due to infections that failed to respond to systemic antibiotic therapy. In terms of place of procedure, there were no significant differences in complication rates between the angiography suite and the mobile operation theater unit. Image-guided chemoport insertion by interventional radiologist gives low periprocedural complication rates. Using right IJV as the entry site, the image guidance gives good success rate with least complication

  10. Hair Loss (Alopecia)

    Science.gov (United States)

    ... care Kids’ zone Video library Find a dermatologist Hair loss Overview Hereditary hair loss: Millions of men ... of hair loss can often be successfully treated. Hair loss: Overview Also called alopecia (al-o-PEE- ...

  11. Net-bottom Cage Inserts for Water Bird Casualties

    Directory of Open Access Journals (Sweden)

    Jackie Belle

    2017-10-01

    Full Text Available My Bright Idea is a net-bottomed cage insert, which is used to support pelagic avian casualties. The idea was designed and modified by the International Bird Rescue in California (Bird Rescue.

  12. Wireless cardiac action potential transmission with ultrasonically inserted silicon microprobes

    International Nuclear Information System (INIS)

    Shen, C J; Ramkumar, A; Lal, A; Gilmour, R F Jr

    2011-01-01

    This paper reports on the integration of ultrasonically inserted horn-shaped cardiac probes with wireless transmission of 3D cardiac action potential measurement for applications in ex vivo preparations such as monitoring the onset of ventricular fibrillation. Ultrasonically inserted silicon horn probes permit reduced penetration force during insertion, allowing silicon, a brittle material, to penetrate cardiac tissue. The probes also allow recording from multiple sites that are lithographically defined. An application-specific integrated circuit has been designed with a 40 dB amplifying stage and a frequency modulating oscillator at 95 MHz to wirelessly transmit the recorded action potentials. This ultrasonically inserted microprobe wireless system demonstrates the initial results in wireless monitoring of 3D action potential propagation, and the extraction of parameters of interest including the action potential duration and diastolic interval

  13. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  14. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan; Zhang, Wenxing; Wan, Wenhui; Cui, Yi; Wang, Enge

    2010-01-01

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a

  15. Fireplace insert and its parameters depend on the used glazing

    Science.gov (United States)

    Papučík, Štefan; Čaja, Alexander

    2016-06-01

    The contribution deals with the analysis of the impact of using double glass to change the performance and emission parameters of the fireplace insert. Conventional fireplace inserts are equipped with heat-resistant glass, which is resistant to high temperatures. For this type of inserts are required to be radiant constituent maximized. Prevailing part of heat is into the interior gets just by radiation through the glazed part. The hot water fireplace inserts is the requirement that the radiant constituent to the environment to a minimum. Therefore, instead of a single glass using double glazing which is intended to reduce this part of heat transfer. The temperature in the furnace is increased, and transmitted most of the heat into the water.

  16. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao; Falivene, Laura; Boffa, Giusi; Sá nchez, Sheila Ortega; Caporaso, Lucia; Grassi, Alfonso; Mecking, Stefan

    2016-01-01

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively

  17. Zero insertion force socket for photoactivation patient treatment system

    International Nuclear Information System (INIS)

    Troutner, V.H.

    1988-01-01

    Automatic operating zero insertion force socket for use in a photoactivatable reagent treatment system wherein photoactivatable agents, in contact with patient blood cells, are irradiated extracorporeally and then returned to the patient

  18. Icing losses on wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, T.; Fotsing, I.; Pearson, S. [Garrad Hassan Canada Inc., Ottawa, ON (Canada)

    2010-07-01

    This PowerPoint presentation discussed some of the energy losses that can occur as a result of icing on wind turbines. Airfoil deterioration can occur in the presence of rime and glaze ice. Anemometers are also impacted by ice, and shut-downs can occur as a result of icing events. Availability deficits that occur during the winter months can lead to annual energy losses of 0.5 percent. The impact of icing events on total wind power energy production in Quebec is estimated at between 1.3 percent to 2.7 percent. Ice loss estimates are considered during the pre-construction phases of wind power projects. However, ice loss prediction methods are often inaccurate. Studies have demonstrated that preconstruction masts show a reasonable correlation with wind turbine icing, and that icing losses are site-specific. tabs., figs.

  19. Timing of Etonogestrel Implant Insertion After Dilation and Evacuation: A Randomized Controlled Trial.

    Science.gov (United States)

    Cowett, Allison A; Ali, Rose; Cooper, Mary A; Evans, Mark; Conzuelo, Gabriel; Cremer, Miriam

    2018-05-01

    To compare the 6-month use rate of the etonogestrel implant placed immediately after dilation and evacuation (D&E) with placement 2-4 weeks postprocedure. This is a randomized controlled trial of women seeking abortion between 14 0/7 and 23 5/7 weeks of gestation and desiring the etonogestrel contraceptive implant at an urban family planning clinic. Participants were randomized to device insertion immediately after the D&E compared with delayed insertion in 2-4 weeks. The primary outcome was implant use rate at 6 months after insertion and was determined by follow-up phone interviews. Secondary outcomes included repeat pregnancy rates and method satisfaction. The sample size of 120 participants was calculated based on a power of 0.80 to demonstrate a 20% difference in implant use rates between groups assuming 40% of women overall are not using the device 6 months after the procedure. Between November 2015 and October 2016, 148 participants were enrolled. Seventy-three participants (49.3%) were randomized to and underwent immediate implant insertion after D&E. The remaining 75 (50.6%) were randomized to delayed insertion. There were no significant differences in sociodemographic characteristics between the groups. Placement rate was 100% in the immediate group compared with 42.7% in the delayed group (P<.01). At 6 months, 40 of 43 (93%) women from the immediate group who completed follow-up continued use of the implant, whereas 19 of 30 (63.3%) women from the delayed group who completed follow-up were using the device (P=.002). Follow-up rates were low at 58.9% in the immediate group compared with 40.0% in the delayed group. Women were more likely to be using the etonogestrel implant at 6 months after D&E if they underwent immediate compared with delayed insertion. The very high loss to follow-up rate makes it difficult to draw conclusions about acceptability of the device and pregnancy rates. ClinicalTrials.gov, 02037919.

  20. Influence of Gradual Elongation to the Patella Tendon Insertion in Rabbits

    Directory of Open Access Journals (Sweden)

    Hirotaka Mutsuzaki

    2014-08-01

    Full Text Available The purpose of this study was to examine the histological changes at the patella tendon (PT insertion site under gradual elongation in rabbits. Gradual elongation of the PT was performed using external fixation for 4 weeks, with a lengthening speed of 0.5 mm/day (elongation group; n = 24. Rabbits in the sham group underwent the same surgical procedure without gradual elongation (sham group; n = 24. Eight animals were sacrificed 1, 2 and 4 weeks after surgery in each group, respectively. Average thicknesses of stained glycosaminoglycan (GAGs areas by Safranin-O staining in the total cartilage layer and the uncalcified fibrocartilage layer in the elongation group were significantly higher than that in the sham group at 4 weeks (p < 0.05 and that in the intact PT group (n = 6, p < 0.05. In the elongation group, the peak in the average thicknesses of the stained GAGs areas in the total cartilage layer and the uncalcified fibrocartilage layer were observed at 4 weeks. Gradual elongation of PT insertion significantly affected the increase in the average thicknesses of the stained GAGs areas in the cartilage layer especially in the uncalcified fibrocartilage layer at 4 weeks in rabbits. Clinically, insertions of tendon and ligament can extend during gradual elongation using external fixation more than 4 weeks after the operation.

  1. Blind bedside insertion of small bowel feeding tubes.

    LENUS (Irish Health Repository)

    Duggan, SN

    2009-12-01

    The use of Naso-Jejunal (NJ) feeding is limited by difficulty in feeding tube placement. Patients have traditionally required transfer to Endoscopy or Radiology for insertion of small bowel feeding tubes, with clear resource implications. We hypothesised that the adoption of a simple bedside procedure would be effective and reduce cost. Clinical nutrition and nurse specialist personnel were trained in the 10\\/10\\/10 method of blind bedside NJ insertion.

  2. Hardening device, by inserts, of electronic component against radiation

    International Nuclear Information System (INIS)

    Val, C.

    1987-01-01

    The hardening device includes at least two materials, one with high atomic number with respect to the other. One of these materials is set as inserts in a layer of the other material. The hardening device is then made by stacking of such layers, the insert density varying from one layer to the other, making thus vary the atomic number resulting from the hardening device along its thickness, following a predefined law [fr

  3. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  4. Some aspects of stray losses in large power transformers

    International Nuclear Information System (INIS)

    Valkovic, Zvonimir

    2002-01-01

    The paper presents some results of the investigation of stray losses in power transformers that are caused by high-current loops. The investigation was focused on: a) additional losses in tank cover around high-current bushings and the way of their reduction, b) extra leakage flux and additional losses due to high current delta-connections. The insertion of nonmagnetic gaps between the phase bushings reduces the extra cover losses more than three times. A nonmagnetic plate around the high-current bushings reduces these extra losses practically to zero. The extra losses due to the high-current delta-connections could be significant for the transformer loss level. These extra losses could be controlled (reduced) by the design layout of the delta-connections. (Author)

  5. Characterization of the relationship between APOBEC3B deletion and ACE Alu insertion.

    Directory of Open Access Journals (Sweden)

    Kang Wang

    Full Text Available The insertion/deletion (I/D polymorphism of the angiotensin converting enzyme (ACE, commonly associated with many diseases, is believed to have affected human adaptation to environmental changes during the out-of-Africa expansion. APOBEC3B (A3B, a member of the cytidine deaminase family APOBEC3s, also exhibits a variable gene insertion/deletion polymorphism across world populations. Using data available from published reports, we examined the global geographic distribution of ACE and A3B genotypes. In tracking the modern human dispersal routes of these two genes, we found that the variation trends of the two I/D polymorphisms were directly correlated. We observed that the frequencies of ACE insertion and A3B deletion rose in parallel along the expansion route. To investigate the presence of a correlation between the two polymorphisms and the effect of their interaction on human health, we analyzed 1199 unrelated Chinese adults to determine their genotypes and other important clinical characteristics. We discovered a significant difference between the ACE genotype/allele distribution in the A3B DD and A3B II/ID groups (P = 0.045 and 0.015, respectively, indicating that the ACE Alu I allele frequency in the former group was higher than in the latter group. No specific clinical phenotype could be associated with the interaction between the ACE and A3B I/D polymorphisms. A3B has been identified as a powerful inhibitor of Alu retrotransposition, and primate A3 genes have undergone strong positive selection (and expansion for restricting the mobility of endogenous retrotransposons during evolution. Based on these findings, we suggest that the ACE Alu insertion was enabled (facilitated by the A3B deletion and that functional loss of A3B provided an opportunity for enhanced human adaptability and survival in response to the environmental and climate challenges arising during the migration from Africa.

  6. Ahmed glaucoma valve implantation with tube insertion through the ciliary sulcus in pseudophakic/aphakic eyes.

    Science.gov (United States)

    Eslami, Yadolla; Mohammadi, Massood; Fakhraie, Ghasem; Zarei, Reza; Moghimi, Sasan

    2014-02-01

    To report the efficacy and safety of Ahmed glaucoma valve (AGV) insertion into the ciliary sulcus in pseudophakic/aphakic patients. A chart review was done on patients with uncontrolled glaucoma, who underwent AGV implantation with tube inserted into the ciliary sulcus. Baseline intraocular pressure (IOP) and number of medications were compared with that of postoperative follow-up visits. Surgical success was defined as last IOP glaucoma control, and without loss of light perception. Postoperative complications were recorded. Twenty-three eyes of 23 patients were recruited with the mean follow-up of 9 months (range, 3 to 24 mo). The mean (SD) age of patients was 49.9 (16.9) years (range, 22 to 80 years). The mean (SD) IOP (mm Hg) was reduced from 37.9 (12.4) before surgery to 16.2 (3.6) at the last follow-up visit (P<0.001). The mean (SD) number of medications was reduced from 3.3 (0.9) preoperatively to 1 (1.1) at the last follow-up (P<0.001). Success rate was 18/23 (78.6%). Complications included endophthalmitis in 1 eye, tube exposure in 1 diabetic patient, and vitreous tube occlusion in 1 eye. No case of corneal decompensation or graft failure was seen during follow-up. Ciliary sulcus placement of the tube of AGV effectively reduces IOP and medication use in short term. It has the potential to lower corneal complications of anterior chamber tube insertion and avoids the need for pars plana vitrectomy and tube insertion in patients at higher risk of corneal decompensation.

  7. Report on converging insert moulding with µ-IM

    DEFF Research Database (Denmark)

    Islam, Aminul

    moulding with µ-IM  Task 5.2.1 and COTECH demonstrator: guide line for 5PRC production based on the concept of Task 5.2.1 Information and results provided by this deliverable will be directly used for one of the COTECH demonstrators production which will call for convergent insert moulding with µ......Task 5.2.1 deals with the technical feasibility of converging the state-of-the-art µ IM process with insert moulding to offer a wide range of multi-material µ components. The main objective of this deliverable is to summarize state-of-the-art information and to make the guideline needed...... for the convergence. In particular the following aspects are summed up in the deliverable:  Need for converging insert moulding with µ-IM  Objectives and expected outcome from task 5.2.1  State-of-the-art micro insert moulding and different scenario of micro insert moulding  Challenges ahead of converging insert...

  8. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  9. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  10. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  11. A selective C-H insertion/olefination protocol for the synthesis of α-methylene-γ-butyrolactone natural products.

    Science.gov (United States)

    Lloyd, Matthew G; D'Acunto, Mariantonietta; Taylor, Richard J K; Unsworth, William P

    2016-02-07

    A regio- and stereoselective one-pot C-H insertion/olefination protocol has been developed for the late stage installation of α-methylene-γ-butyrolactones into conformationally restricted cyclohexanol-derivatives. The method has been successfully applied in the total synthesis of eudesmanolide natural product frameworks, including α-cyclocostunolide.

  12. Probabilistic analysis and material characterisation of canister insert for spent nuclear fuel. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Claes-Goeran [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Andersson, Mats; Erixon, Bo [AaF Industriteknik, Stockholm (Sweden); Bjoerkegren, Lars-Erik [Swedish Foundry Association, Stockholm (Sweden); Dillstroem, Peter [DNV Technology, Stockholm (Sweden); Minnebo, Philip

    2005-11-15

    The KBS-3 canister for geological disposal of spent nuclear fuel in Sweden consists of a ductile cast iron insert and a copper shielding. The canister should inhibit release of radionuclides for at least 100,000 years. The copper protects the canister from corrosion whereas the ductile cast iron insert provides the mechanical strength. In the repository the hydrostatic pressure from the groundwater and the swelling pressure from the surrounding bentonite, which in total results in a maximum pressure of 14 MPa, will load the canisters in compression. During the extreme time scales, ice ages are expected with a maximum ice thickness of 3,000 m resulting in an additional pressure of 30 MPa. The maximum design pressure for the KBS-3 canisters has therefore been set to be 44 MPa. A relatively large number of canisters have been manufactured as part of SKB's development programme. To verify the strength of the canisters at this stage of development SKB initiated a project in cooperation with the European commissions Joint Research Centre (JRC), Institute of Energy in Petten in the Netherlands, together with a number of other partners. Three inserts manufactured by different Swedish foundries were used in the project. A large statistical test programme was developed to determine statistical distributions of various material parameters and defect distributions. These data together with the results from stress and strain finite element analysis were subsequently used in probabilistic analysis to determine the probability for plastic collapse caused by high pressure or fracture by crack growth in regions with tensile stresses. The main conclusions from the probabilistic analysis are: 1. At the design pressure of 44 MPa, the probability of failure is insignificant ({approx}2x10{sup -9}). This is the case even though several conservative assumptions have been made. 2. The stresses in the insert caused by the outer pressure are mainly compressive. The regions with tensile

  13. The Effect of a Glass Ceramic Insert in Sandwich Technique on Microleakage in Class II Composite Resin Restorations

    Directory of Open Access Journals (Sweden)

    Hila Hajizadeh

    2015-06-01

    Full Text Available Introduction: The aim of the present study was to evaluate the effect of glass ceramic insert in the sandwich technique to reduce microleakage in class II composite resin restorations. Methods: Sixty sound human upper second premolars were selected and randomly divided into six groups (n=10. Class II box-only cavities were prepared in distal aspects of each tooth with gingival margin located approximately 0.5 mm below the CEJ. Group A (Control was restored incrementally with Tetric Ceram and a total-etch bonding technique. Group B and C were restored with sandwich technique using a compomer (Compoglass F or flowable composite resin (Tetric Flow as the lining material at gingival floor, respectively. Group D, E and F were represented in the same way as group A, B and C and a glass ceramic insert was added to the composite bulk. The specimens were thermo-mechanically cycled, and then immersed in 0.5 % basic fuschin for 24 hours. Dye penetration was detected using a sectioning technique. Results: No significant difference was found between total-etch bonding and sandwich techniques. The placement of an insert caused an increase in   microleakage in all groups significantly (P < 0.05. Group D (no liner/ with glass insert showed the highest amount of microleakage and Group A (no liner/ without glass insert resulted in the lowest amount of total microleakage. Conclusion: Placement of glass ceramic insert could not decrease gingival leakage. According to the limitation of this study a composite resin restorations with incremental technique is recommended

  14. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-27

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  15. Unilateral versus bilateral stent insertion for malignant hilar biliary obstruction.

    Science.gov (United States)

    Chang, Gang; Xia, Feng-Fei; Li, Hong-Fu; Niu, Su; Xu, Yuan-Shun

    2017-11-01

    To determine the clinical efficiency and long-term outcomes between unilateral and bilateral stent insertion in patients with malignant hilar biliary obstruction. From August 2012 to February 2016, 63 consecutive patients with malignant hilar biliary obstruction were treated with unilateral or bilateral stent insertion at our center. The bilateral stents were inserted using the side-by-side technique. The clinical efficiency and long-term outcomes were compared between the two groups. Unilateral and bilateral stent insertions were successfully performed in 31 of 33 and 27 of 30 patients, respectively (P = 0.912). No procedure-related complication occurred. Clinical success was achieved in 29 of 31 patients in the unilateral stent group and in 26 of 27 patients in the bilateral stent group (P = 0.637). During the follow-up, re-obstruction of stent occurred in five patients in the unilateral stent group and in three patients in the bilateral stent group (P = 0.58). The significant differences were not observed in the stent patency time (368 vs. 387 days, P = 0.685) and survival (200 vs. 198 days, P = 0.751) between two groups. Based on the univariate and multivariate analyses, the independent risk factors for decreasing the survival time included higher Eastern Cooperative Oncology Group performance status (P = 0.018), higher alanine aminotransferase level (P = 0.009), and absence of anticancer treatment after stent insertion (P = 0.002). Compared to bilateral stent insertion for malignant hilar biliary obstruction, unilateral stent insertion can provide comparable clinical efficiency and long-term outcomes.

  16. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  17. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  18. AC loss performance of cable-in-conduit conductor. Influence of cable mechanical property on coupling loss reduction

    International Nuclear Information System (INIS)

    Matsui, Kunihiro; Koizumi, Norikiyo; Isono, Takaaki; Hamada, Kazuya; Nunoya, Yoshihiko

    2003-01-01

    The ITER Central Solenoid (CS) model coil, CS Insert and Nb 3 Al Insert were developed and tested from 2000 to 2002. The AC loss performances of these coils were investigated in various experiments. In addition, the AC losses of the CS and Nb 3 Al Insert conductors were measured using short CS and Nb 3 Al Insert conductors before the coil tests. The coupling time constants of these conductors were estimated to be 30 and 120 ms, respectively. On the other hand, the test results of the CS and Nb 3 Al Inserts show that the coupling currents induced in these conductors had multiple decay time constants. In fact, the existence of the coupling currents with long decay time constants, the order of which was in the thousands of seconds, was directly observed with hall sensors and voltage taps. Moreover, the AC loss test results show that electromagnetic force decreases coupling losses with exponential decay constants. This is because the weak sinter among the strands, which originated during heat treatment, was broken due to the electromagnetic force, and then the contact resistance among strands increased. It was found that this exponential decay constant was the function of a gap (i.e., a mechanical property of the cable) created between the cable and conduit due to electromagnetic force. The gap can be estimated by pressure drop, measured under the electromagnetic force. The pressure drop can easily be measured at an initial trial charge, and then it is possible to estimate the exponential decay constant before normal coil operation. Accordingly, it is possible to predict promptly how many times the trial operations are necessary to decrease the coupling losses to the designed value by measuring the coupling losses and the pressure drop during the initial coil operation trial. (author)

  19. Immediate versus delayed insertion of an etonogestrel releasing implant at medical abortion-a randomized controlled equivalence trial.

    Science.gov (United States)

    Hognert, Helena; Kopp Kallner, Helena; Cameron, Sharon; Nyrelli, Christina; Jawad, Izabella; Heller, Rebecca; Aronsson, Annette; Lindh, Ingela; Benson, Lina; Gemzell-Danielsson, Kristina

    2016-11-01

    Does a progestin releasing subdermal contraceptive implant affect the efficacy of medical abortion if inserted at the same visit as the progesterone receptor modulator, mifepristone, at medical abortion? A etonogestrel releasing subdermal implant inserted on the day of mifepristone did not impair the efficacy of the medical abortion compared with routine insertion at 2-4 weeks after the abortion. The etonogestrel releasing subdermal implant is one of the most effective long acting reversible contraceptive methods. The effect of timing of placement on the efficacy of mifepristone and impact on prevention of subsequent unintended pregnancy is not known. This multicentre, randomized controlled, equivalence trial with recruitment between 13 October 2013 and 17 October 2015 included a total of 551 women with pregnancies below 64 days gestation opting for the etonogestrel releasing subdermal implant as postabortion contraception. Women were randomized to either insertion at 1 hour after mifepristone intake (immediate) or at follow-up 2-4 weeks later (delayed insertion). An equivalence design was used due to advantages for women such as fewer visits to the clinic with immediate insertion. The primary outcome was the percentage of women with complete abortion not requiring surgical intervention within 1 month. Secondary outcomes included insertion rates, pregnancy and repeat abortion rates during 6 months follow-up. Analysis was per protocol and by intention to treat. Women aged 18 years and older who had requested medical termination of a pregnancy up to 63 days of gestation and opted for an etonogestrel releasing contraceptive implant were recruited in outpatient family planning clinics in six hospitals in Sweden and Scotland. Efficacy of medical abortion was 259/275 (94.2%) in the immediate insertion group and 239/249 (96%) in the routine insertion group with a risk difference of 1.8% (95% CI -0.4 to 4.1%), which was within the ±5% margin of equivalence. The insertion

  20. In vitro wear assessments of fixed and mobile UHMWPE total knee replacement

    International Nuclear Information System (INIS)

    Affatato, Saverio; Bracco, Pierangiola; Sudanese, Alessandra

    2013-01-01

    Highlights: ► In this study we examined the wear behaviour of total knee UHMWPE menisci. ► We used two different knee designs: mobile and fixed menisci. ► We used a knee simulator and FTIR analyses to evaluate the wear behaviour. ► Our conclusions are that the two designs had a different wear behaviour. - Abstract: This work discusses the wear behaviour of two different ultra-high-molecular-weight-polyethylene tibial component designs. Mobile and fixed bearings were tested on a knee wear simulator for 5 million cycles using bovine calf serum as lubricant. We correlated the wear results with the chemical characterisation of the investigated materials: Fourier Transformed Infra Red Spectroscopy analyses, Differential Scanning Calorimetry and cross-link density measurements were used to assess the chemical features of this polyethylene. Mobile and fixed polyethylene inserts showed a different wear behaviour: the mobile designs components showed lower weight losses than the fixed components (109 ± 6 mg and 163 ± 80 mg, respectively). Significant statistical differences were observed in wear rate (P = 0.035, Kolmogorov–Smirnov Test for two samples). From a molecular point of view, typical radiation-induced oxidation profiles were observed in all the tested polyethylene samples, but the overall degradation was more significant in the fixed bearing inserts and this is likely to play a role on the wear performances

  1. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  2. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  3. Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy

    International Nuclear Information System (INIS)

    Verma, S.P.; Sonwalkar, N.

    1993-01-01

    The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22 o C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm -1 (amide I), 1200-1300 cm -1 (amide III) and 550-1030 cm -1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm -1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and III bands. Quantitative estimation using the curve fitting method shows that ban 3 contains 44% total helix, 48% beta strand and 8% undefined plus turns (error + or - 4%). The secondary structure changes to 35% total helix, 42% total beta-strand and 23% turned and undefined upon irradiating band 3 containing liposomes. (Author)

  4. A novel method for improving chest tube insertion skills among medical interns. Using biomaterial-covered mannequin

    Directory of Open Access Journals (Sweden)

    Ozgur Tatli

    2017-10-01

    Full Text Available Objectives: To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42. Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand.

  5. A novel method for improving chest tube insertion skills among medical interns. Using biomaterial-covered mannequin.

    Science.gov (United States)

    Tatli, Ozgur; Turkmen, Suha; Imamoglu, Melih; Karaca, Yunus; Cicek, Mustafa; Yadigaroglu, Metin; Bayrak, Selen T; Asik, Olgun; Topbas, Murat; Turedi, Suleyman

    2017-10-01

    To develop a low-cost biomaterial-covered chest tube simulation model and assess its possible usefulness for developing the chest tube insertion skills among medical interns. Methods: This mannequin-based interventional study was performed in a University hospital setting. We included 63 physicians performing emergency medicine internship at the Faculty of Medicine, Karadeniz Technical University, Trabzon, Turkey, between January 2015 and March 2015. A dummy was prepared for training simulation using a display mannequin. Medical interns received instruction concerning pneumothorax and the chest tube procedure. A total of 63 medical interns participating in this interventional study were asked to insert a chest tube in a biomaterial-covered mannequin. A senior trainee scored their performance using a check list and the mean of the total scores was calculated (21 items; total score, 42). Results: The mean procedural score was 40.9 ± 1.3 of a possible 42. The maximum score of 42 was achieved by 39.7% of the medical interns, while another 33.3% achieved a score of 41. Of the participants, 85% succeeded in inserting the tube via an appropriate technique, achieving a score of 40 or more. Conclusion: Our results indicated that this model could be useful for effective training of medical interns for chest tube insertion, which is an important skill in emergency medicine. This biomaterial-covered model is inexpensive and its use can potentially be widened to improve training methods without significant financial demand.

  6. Analysis of generic insertions made of two symmetric triplets

    CERN Document Server

    D'Amico, T E

    1998-01-01

    This paper reports on the study undertaken to explore the capabilities of a symmetric triplet to achieve the optics constraints required by the inner triplet of an insertion and more generally of a co mplete insertion made of two symmetric triplets to match a double focus to a FODO lattice. It is based on analytical treatment formulating a number of constraints equal to the parameters available. Th is thorough and systematic analysis made it possible to establish for an inner triplet as well as for a complete insertion the existence of solutions and to explicitly find out all the solutions, with out resorting to unguided numerical searches. As a by-product, a lattice transformer, made of a single triplet, that matches two different FODO cells has been singled out and studied in details. The r esults should be profitable in a number of cases. Here, the method is applied to an insertion of the type of an experimental LHC insertion in order to investigate its domain of validity and tunability .

  7. Sorting genomes by reciprocal translocations, insertions, and deletions.

    Science.gov (United States)

    Qi, Xingqin; Li, Guojun; Li, Shuguang; Xu, Ying

    2010-01-01

    The problem of sorting by reciprocal translocations (abbreviated as SBT) arises from the field of comparative genomics, which is to find a shortest sequence of reciprocal translocations that transforms one genome Pi into another genome Gamma, with the restriction that Pi and Gamma contain the same genes. SBT has been proved to be polynomial-time solvable, and several polynomial algorithms have been developed. In this paper, we show how to extend Bergeron's SBT algorithm to include insertions and deletions, allowing to compare genomes containing different genes. In particular, if the gene set of Pi is a subset (or superset, respectively) of the gene set of Gamma, we present an approximation algorithm for transforming Pi into Gamma by reciprocal translocations and deletions (insertions, respectively), providing a sorting sequence with length at most OPT + 2, where OPT is the minimum number of translocations and deletions (insertions, respectively) needed to transform Pi into Gamma; if Pi and Gamma have different genes but not containing each other, we give a heuristic to transform Pi into Gamma by a shortest sequence of reciprocal translocations, insertions, and deletions, with bounds for the length of the sorting sequence it outputs. At a conceptual level, there is some similarity between our algorithm and the algorithm developed by El Mabrouk which is used to sort two chromosomes with different gene contents by reversals, insertions, and deletions.

  8. Insertion compounds of transition-metal and uranium oxides

    International Nuclear Information System (INIS)

    Chippindale, A.M.; Dickens, P.G.; Powell, A.V.

    1991-01-01

    Several transition-metal and actinide oxides, in which the metal occurs in a high oxidation state, have open covalent structures and are capable of incorporating alkali and other electropositive metals under mild conditions to form insertion compounds A x MO n . These are solids which have several features in common: Over a range of compositions, A x MO n exists as one or more stable or metastable phases in which the structure of the parent oxide MO n is largely retained and the insertion element A is accommodated interstitially. Insertion is accompanied by a redox process A=A i . + e - M in which M is reduced and the electronic properties of the parent oxide change to those typical of a mixed-valence compound. The insertion process xA + MO n = A x MO n can be reversed, at least to some extent, by chemical or electrochemical reaction, with retention of structure (topotactic reaction). This review concentrates on methods of synthesis, characterisation, crystal structure and thermochemistry of these insertion compounds. It updates and extends previous work. (author)

  9. Seamless lesion insertion in digital mammography: methodology and reader study

    Science.gov (United States)

    Pezeshk, Aria; Petrick, Nicholas; Sahiner, Berkman

    2016-03-01

    Collection of large repositories of clinical images containing verified cancer locations is costly and time consuming due to difficulties associated with both the accumulation of data and establishment of the ground truth. This problem poses a significant challenge to the development of machine learning algorithms that require large amounts of data to properly train and avoid overfitting. In this paper we expand the methods in our previous publications by making several modifications that significantly increase the speed of our insertion algorithms, thereby allowing them to be used for inserting lesions that are much larger in size. These algorithms have been incorporated into an image composition tool that we have made publicly available. This tool allows users to modify or supplement existing datasets by seamlessly inserting a real breast mass or micro-calcification cluster extracted from a source digital mammogram into a different location on another mammogram. We demonstrate examples of the performance of this tool on clinical cases taken from the University of South Florida Digital Database for Screening Mammography (DDSM). Finally, we report the results of a reader study evaluating the realism of inserted lesions compared to clinical lesions. Analysis of the radiologist scores in the study using receiver operating characteristic (ROC) methodology indicates that inserted lesions cannot be reliably distinguished from clinical lesions.

  10. Guide tube insert assembly for use in a nuclear reactor

    International Nuclear Information System (INIS)

    Hopkins, R.J.; Land, J.T.

    1992-01-01

    This patent describes an internals assembly for a nuclear reactor of the type including an upper support plate and an upper core plate, each having apertures for conducting control rod assemblies into an out of fuel assemblies with the apertures of the upper support plate being aligned with the apertures of the upper core plate, a guide tube insert assembly comprising: an elongated tubular body extending between at least one of the aligned apertures formed in the upper support plate and the upper core plate; guide plates within the elongated tubular body, each of the guide plates having a planar surface extending substantially perpendicular to an axial direction of the tubular body; at least one interconnecting means for interconnecting the guide plates into a guide tube insert assembly such that the guide plates are simultaneously mountable within and removable from the elongated body, and the periphery of each of the guide plates is spaced apart from the inner walls of the elongated tubular body at every point when the insert assembly is mounted within the tubular body, and a stabilizing means for securing the lowermost guide plate of the guide tube insert assembly within the elongated tubular body to prevent rotational and lateral movement between the guide tube insert assembly and the tubular body

  11. Initial tension loss in cerclage cables.

    Science.gov (United States)

    Ménard, Jérémie; Émard, Maxime; Canet, Fanny; Brailovski, Vladimir; Petit, Yvan; Laflamme, George Y

    2013-10-01

    Cerclage cables, frequently used in the management of fractures and osteotomies, are associated with a high failure rate and significant loosening during surgery. This study compared the capacity to maintain tension of different types of orthopaedic cable systems. Multifilament Cobalt-Chrome (CoCr) cables with four different crimp/clamp devices (DePuy, Stryker, Zimmer and Smith&Nephew) and one non-metallic Nylon (Ny) cable from Kinamed were instrumented with a load cell to measure tension during insertion. Significant tension loss was observed with crimping for all cables (Ptensioner led to an additional unexpected tension loss (CoCr-DePuy: 18%, CoCr-Stryker: 29%, CoCr-Smith&Nephew: 33%, Ny: 46%, and CoCr-Zimmer: 52%). The simple CoCr (DePuy) cable system outperformed the more sophisticated locking devices due to its significantly better ability to prevent tension loss. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Mastery learning improves students skills in inserting intravenous access: a pre-post-study.

    Science.gov (United States)

    Friederichs, Hendrik; Brouwer, Britta; Marschall, Bernhard; Weissenstein, Anne

    2016-01-01

    Inserting peripheral venous catheters (PVCs) has been identified as a core competency for medical students. Because the performance - even of hygienic standards - of both students and novice physicians is frequently inadequate, medical faculties must focus on competence-based learning objectives and deliberate practice, features that are combined in mastery learning. Our aim was to determine the competency of students in inserting PVCs before and after an educational intervention. This study comprised a skills assessment with pre- and post-tests of a group of third-year students who received a simulation-based intervention. A newly established curriculum involved one hour of practice at inserting PVCs on simulators. Students were required to pass a test (total 21 points, pass mark 20 points) developed on the concept of mastery learning. An unannounced follow-up test was performed one week (8 days) after the intervention. The simulation center of the medical faculty in Muenster. Third-year students who received the intervention. One hundred and nine complete data sets were obtained from 133 students (82.5%). Most students (97.2%) passed the test after the intervention (mean score increase from 15.56 to 20.50, Pstudents' performance after one week (8 days): only 74.5% of participants passed this retest (mean score reduction from 20.50 to 20.06, Plearning is an effective form of teaching practical skills to medical students, allowing a thorough preparation for the challenges of daily clinical practice.

  13. Complications of Percutaneous Nephrostomy, Percutaneous Insertion of Ureteral Endoprosthesis, and Replacement Procedures

    International Nuclear Information System (INIS)

    Kaskarelis, Ioannis S.; Papadaki, Marina G.; Malliaraki, Niki E.; Robotis, Epaminondas D.; Malagari, Katerina S.; Piperopoulos, Ploutarchos N.

    2001-01-01

    Purpose: The aim of the present study was to record and identify the frequency of complications following percutaneous nephrostomy, replacement of nephrostomy drains and percutaneous insertion of ureteral endoprostheses.Methods: During a 10-year period 341 patients were referred to our department with indications for percutaneous nephrostomy and/or percutaneous insertion of a ureteral endoprosthesis, and a total of 1036 interventional procedures were performed (nephrostomy, catheter change, stenting).Results: There were three major complications (0.29%): two patients died during the first 30 days after the procedure, due to aggravation of their condition caused by the procedure, and one patient had retroperitoneal bleeding requiring surgery. There were 76 complications of intermediate severity (7.33%): catheter or stent displacement (n = 37, 3.57%) catheter occlusion (n = 18, 1.73%), hematuria (n = 12, 1.16%), and urinary tract infection (n = 9, 0.87%). The 55 minor complications (5.3%) comprised inflammation of the skin at the site of insertion of the percutaneous catheter.Conclusion: The small number of complications observed during acts of interventional uroradiology prove transcutaneous manipulations to be safe medical procedures

  14. Mass loss from S stars

    International Nuclear Information System (INIS)

    Jura, M.

    1988-01-01

    The mass-loss process in S stars is studied using 65 S stars from the listing of Wing and Yorka (1977). The role of pulsations in the mass-loss process is examined. It is detected that stars with larger mass-loss rates have a greater amplitude of pulsations. The dust-to-gas ratio for the S stars is estimated as 0.002 and the average mass-loss rate is about 6 x 10 to the -8th solar masses/yr. Some of the properties of the S stars, such as scale height, surface density, and lifetime, are measured. It is determined that scale height is 200 pc; the total duration of the S star phase is greater than or equal to 30,000 yr; and the stars inject 3 x 10 to the -6th solar masses/sq kpc yr into the interstellar medium. 46 references

  15. The strategic use of inserts in the Brazilian presidential elections

    Directory of Open Access Journals (Sweden)

    Felipe Borba

    2012-01-01

    Full Text Available The aim of this article is to analyze the communication strategies of presidential candidates during the elections held in 2006 and 2010. The focus is on the strategic component of electoral inserts and the methodology consists of investigating how candidates choose to distribute these inserts in the programming of television networks. The results indicate that the candidates pursue different strategies influenced basically by three variables: electoral legislation, their standing in polls and the difference of resources available. In parallel, the article debates the role of the regulation of electoral advertising and how this set of rules influences the level of information of campaigns, the occurrence of attacks, and party strategies. Overall, 2,993 electoral inserts were examined.

  16. Variation in the insertion of the palmaris longus tendon

    Science.gov (United States)

    Sunil, Vinutha; Rajanna, Shubha; Gitanjali; Kadaba, Jayanthi

    2015-01-01

    The palmaris longus is harvested as a tendon graft in various surgical procedures. We herein report the variations in the insertion of the palmaris longus tendon. During a routine dissection, a rare variation in the insertion of the palmaris longus tendon was observed. In the left forearm, the palmaris longus tendon bifurcated, while in the right forearm, the palmaris longus tendon trifurcated, giving rise to an accessory muscle, which passed superficial to the ulnar artery and ulnar nerve. The accessory muscle was supplied by a deep branch of the ulnar nerve, and the ulnar artery was observed to be tortuous. During reconstructive surgeries, surgeons should bear in mind the accessory muscle. Also, since the palmaris longus muscle provides a very useful graft in tendon surgery, every surgeon should be aware of the variations in the insertion of the palmaris longus tendon. PMID:25640108

  17. Indentation and needle insertion properties of the human eye.

    Science.gov (United States)

    Matthews, A; Hutnik, C; Hill, K; Newson, T; Chan, T; Campbell, G

    2014-07-01

    Characterization of the biomechanical properties of the human eye has a number of potential utilities. One novel purpose is to provide the basis for development of suitable tissue-mimicking material. The purpose of this study was to determine the indentation and needle insertion characteristics on human eye globes and tissue strips. An indenter assessed the elastic response of human eye globes and tissue strips under increasing compressive loads. Needle insertion determined the force (N) needed to penetrate various areas of the eye wall. The results demonstrated that globes underwent slightly greater indentation at the midline than at the central cornea, and corneal strips indented twofold more than scleral strips, although neither difference was significant (P=0.400 and P=0.100, respectively). Significant differences were observed among various areas of needle insertion (Phuman eye construct with potential utility as a model for use in ophthalmology research and surgical teaching.

  18. Insertion of liquid crystal molecules into hydrocarbon monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Piotr, E-mail: ppopov@kent.edu; Mann, Elizabeth K. [Department of Physics, Kent State University, Kent, Ohio 44242 (United States); Lacks, Daniel J. [Department of Chemical Engineering, Case Western Reserve University, Cleveland, Ohio 44106 (United States); Jákli, Antal [Liquid Crystal Institute, Kent State University, Kent, Ohio 44242-0001 (United States)

    2014-08-07

    Atomistic molecular dynamics simulations were carried out to investigate the molecular mechanisms of vertical surface alignment of liquid crystals. We study the insertion of nCB (4-Cyano-4{sup ′}-n-biphenyl) molecules with n = 0,…,6 into a bent-core liquid crystal monolayer that was recently found to provide good vertical alignment for liquid crystals. The results suggest a complex-free energy landscape for the liquid crystal within the layer. The preferred insertion direction of the nCB molecules (core or tail first) varies with n, which can be explained by entropic considerations. The role of the dipole moments was found to be negligible. As vertical alignment is the leading form of present day liquid crystal displays (LCD), these results will help guide improvement of the LCD technology, as well as lend insight into the more general problem of insertion of biological and other molecules into lipid and surfactant layers.

  19. Master-slave robotic system for needle indentation and insertion.

    Science.gov (United States)

    Shin, Jaehyun; Zhong, Yongmin; Gu, Chengfan

    2017-12-01

    Bilateral control of a master-slave robotic system is a challenging issue in robotic-assisted minimally invasive surgery. It requires the knowledge on contact interaction between a surgical (slave) robot and soft tissues. This paper presents a master-slave robotic system for needle indentation and insertion. This master-slave robotic system is able to characterize the contact interaction between the robotic needle and soft tissues. A bilateral controller is implemented using a linear motor for robotic needle indentation and insertion. A new nonlinear state observer is developed to online monitor the contact interaction with soft tissues. Experimental results demonstrate the efficacy of the proposed master-slave robotic system for robotic needle indentation and needle insertion.

  20. Understanding Grief and Loss

    Science.gov (United States)

    ... the process of adapting to life after a loss. It is influenced by each person’s society, culture, and religion. Bereavement is the state of having experienced a loss. Common grief reactions Reactions to loss are called ...

  1. Fixation of the Achilles tendon insertion using suture button technology.

    Science.gov (United States)

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  2. Mammographic and Ultrasonographic Findings of the Chemoport Insertion Site

    International Nuclear Information System (INIS)

    Kim, Seun Jung; Kang, Bong Joo; Cha, Eun Suk; Park, Hye Jung; Kim, Sung Hun; Choi, Jae Jeong; Lee, Ji Hye

    2010-01-01

    To describe mammographic and ultrasonographic findings of previous chemoport insertion sites. We included patients who had abnormal findings at chemoport insertion sites on mammography and ultrasonography from 224 patients who underwent chemoport insertion and breast imaging at our institution between January, 2005, and December, 2007. Abnormal findings were identified in 16 mammographies and 14 ultrasonographies in 10 patients. The mean age was 50.9 years and the age range was from 44 to 67 years. Abnormal findings on mammography and ultrasonography were retrospectively analyzed according to ACR/BI-RADS. All cases were followed up with imaging studies for 2 years to confirm changes after chemoport insertion. Of the abnormal findings identified on mammography, focal asymmetry (7/16) was the most common. Other abnormal findings included mass (6/16), skin retraction (2/16), residual chemoport tip (1/16), and trabecular thickening (1/16). Of the abnormal findings seen on ultrasonography, skin thickening (12/14) was the most common. Other abnormal findings included mass (5/14), diffuse increased echogenicity of subcutaneous tissue (1/14), and a localized skin nodule (1/14). Abnormal findings on mammography and ultrasonography were located in the upper outer quadrant in 5 patients, upper inner quadrant in 3 patients, and mid upper portion in 1 patient. In 1 patient, the abnormal finding was only identified in the mediolateral oblique view of her mammography. Radiologists should be aware of potential abnormal findings on mammography and ultrasonography following chemoport insertion. In particular, ultrasonography is a very useful modality for detecting skin complications after chemoport insertion

  3. Characterisation of protein stability in rod-insert vaginal rings.

    Science.gov (United States)

    Pattani, Aditya; Lowry, Deborah; Curran, Rhonda M; McGrath, Stephanie; Kett, Vicky L; Andrews, Gavin P; Malcolm, R Karl

    2012-07-01

    A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4 °C, but not when stored at 40 °C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40 °C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40 °C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general. Copyright

  4. Oral dextrose for analgesia in neonates during nasogastric tube insertion: a randomised controlled trial.

    Science.gov (United States)

    Ravishankar, Arjun; Thawani, Rajat; Dewan, Pooja; Das, Saurabhi; Kashyap, Archana; Batra, Prerna; Faridi, Moonis Mohammed Akbar

    2014-02-01

    This study aims to determine if oral dextrose solution can mitigate the pain response to nasogastric tube (NGT) insertion in neonates. The study was a double-blinded, placebo-controlled, randomised controlled trial. One hundred and fifty consecutive neonates were randomised into three groups to receive 25% dextrose (D25), or 10% dextrose (D10) or placebo (distilled water). An NGT was inserted after giving 2 mL of one of the solutions orally. Pain response was assessed using the Premature Infant Pain Profile (PIPP), and the duration of cry was noted within 60 s of the intervention. Total PIPP score, duration of cry, change in heart rate and oxygen saturation (SpO2 ) were compared among the three groups. Neonates who received D25 had significantly lesser pain response to NGT insertion in terms of lower PIPP score (P < 0.05) and duration of cry (P = 0.001) compared to D10. There was a significantly smaller increase in heart rate and decrease in SpO2 (P < 0.05). In comparison with placebo, D10 significantly decreased duration of cry (P < 0.05) but not PIPP score. Oral D25 was effective in reducing the pain response during NGT insertion in neonates when compared with oral D10 and placebo. Oral D10 was not found to have a potent analgesic effect for the same. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  5. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    International Nuclear Information System (INIS)

    Power, Sarah; Kavanagh, Liam N.; Shields, Mary C.; Given, Mark F.; Keeling, Aoife N.; McGrath, Frank P.; Lee, Michael J.

    2013-01-01

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period. Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.

  6. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.; Given, Mark F.; Keeling, Aoife N.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2013-04-15

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period. Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.

  7. SU-D-213AB-06: Surface Texture and Insertion Speed Effect on Needle Friction.

    Science.gov (United States)

    Abdullah, A; Golecki, C; Barnett, A; Moore, J

    2012-06-01

    High frictional forces between the needle surface and tissue cause tissue deflection which hinders accurate needle placement for procedures such as brachytherapy and needle biopsy. Accurate needle placement isimportant to maximize procedure efficacy. This work investigates how needle surface roughness and insertion speed affect the frictional forcebetween a needle and tissue. A friction experiment was conducted to measure the force of friction between bovine liver and three 11 gauge needles having Ra surface roughness of 3.43, 1.33, and 0.2 μm. Each of the three needles were mounted on a linear slide and were advanced and retracted through bovine liver at speeds of 50, 100, 150, and 200 mm/s for a total of 12 trials. In each trial the needle was advanced and retracted in 10 cycles producing a steady state insertion force and a steady state retraction force for each cycle. A force sensor connecting the needle to the linear slide recorded the resistance force of the needle sliding through the liver. The liver was mounted in a box with a pneumatic cylinder which compressed the liver sample by 11.65 kPa. The roughest needle (Ra = 3.43 μm) on average produced 68, 73, 74, and 73% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200mm/s, respectively. The second roughest needle (Ra = 1.33 μm) on average produced 25, 45, 60 and 64% lower friction force than the smoothest needle (Ra = 0.2 μm) for the speeds of 50, 100, 150, and 200 mm/s, respectively. Rougher needle surface texture and higher insertion speed reduced frictional forces between the tissue and the needle. Future studies will examine how frictional forces can be modeled and predicted given surface texture and insertion speed. © 2012 American Association of Physicists in Medicine.

  8. The effects of an inserted linear carbon chain on the vibration of a carbon nanotube

    International Nuclear Information System (INIS)

    Hu, Z L; Guo, X M; Ru, C Q

    2007-01-01

    An elastic string-elastic shell model is developed to study the coupled vibration of a carbon nanowire made of a linear carbon chain (C-chain) inserted inside a carbon nanotube (CNT). It is shown that the vibration of the inserted C-chain is coupled with vibration of the CNT only for vibration modes with circumferential wavenumber n = 1. In other cases, such as axisymmetric modes (n = 0) or higher-order vibration modes with n≥2, total resultant van der Waals (vdW) force acting on the C-chain due to the innermost tube always vanishes, and therefore vibration of the CNT does not cause vibration of the inserted C-chain, although the existence of the C-chain does have an effect on the vibration of the CNT through the chain-CNT vdW forces acting on the innermost tube. The present model predicts that non-coaxial vibration between the C-chain and the innermost tube does not occur due to negligible bending rigidity of the C-chain. In addition, it is found that the C-chain has most significant effect on the lowest frequency associated with the radial vibration mode for circumferential wavenumber 2 (n = 2). In particular, the effect of the C-chain on the axisymmetric radial breathing frequencies (n = 0) predicted by the present model is found to be in reasonable agreement with known experimental and modeling results available in the literature. The present work offers systematic modeling results on the effects of an inserted C-chain on the vibration of CNTs

  9. Tension Pneumothorax and Subcutaneous Emphysema Complicating Insertion of Nasogastric Tube

    Directory of Open Access Journals (Sweden)

    Narjis AL Saif

    2015-01-01

    Full Text Available Nasogastric tube has a key role in the management of substantial number of hospitalized patients particularly the critically ill. In spite of the apparent simple insertion technique, nasogastric tube placement has its serious perhaps fatal complications which need to be carefully assessed. Pulmonary misplacement and associated complications are commonplace during nasogastric tube procedure. We present a case of tension pneumothorax and massive surgical emphysema in critically ill ventilated patient due to inadvertent nasogastric tube insertion and also discussed the risk factors, complication list, and arrays of techniques for safer tube placement.

  10. Can femoral dialysis catheter insertion cause a life threatening complication?

    Directory of Open Access Journals (Sweden)

    Nurkay Katrancıoğlu

    2014-09-01

    Full Text Available Venous catheter (VC insertion may be necessary for the patients with renal failure facing vascular access problem. Femoral VCs are commonly used for their lower complication rates especially in emergency clinics. The incidence of bleeding associated with VC is reported 0.5-1.6%, however, life threatening hemorrhage and complications requiring surgical intervention are very rare. In this manuscript, we aimed to present a case with hemolytic uremic syndrome complicated with retroperitoneal hematoma after femoral VC insertion. J Clin Exp Invest 2014; 5 (3: 472-474

  11. Direct Synthesis of Telechelic Polyethylene by Selective Insertion Polymerization

    KAUST Repository

    Jian, Zhongbao

    2016-10-14

    A single-step route to telechelic polyethylene (PE) is enabled by selective insertion polymerization. PdII-catalyzed copolymerization of ethylene and 2-vinylfuran (VF) generates α,ω-di-furan telechelic polyethylene. Orthogonally reactive exclusively in-chain anhydride groups are formed by terpolymerization with carbic anhydride. Combined experimental and theoretical DFT studies reveal the key for this direct approach to telechelics to be a match of the comonomers’ different electronics and bulk. Identified essential features of the comonomer are that it is an electron-rich olefin that forms an insertion product stabilized by an additional interaction, namely a π–η3 interaction for the case of VF.

  12. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  13. Degradation rate of acetylcholine receptors inserted into denervated vertebrate neuromuscular junctions

    International Nuclear Information System (INIS)

    Shyng, S.L.; Salpeter, M.M.

    1989-01-01

    Many studies exist on the effect of denervation on the degradation of acetylcholine receptors (AChRs) at the vertebrate neuromuscular junction (nmj). These studies have described the behavior of either the total population of junctional receptors at different times after denervation, or of the receptors present at the time of denervation. No experimental studies yet exist on the degradation rate of the receptors newly inserted into denervated junctions. In the previous studies, the original receptors of mouse sternomastoid muscles were found to retain the slow degradation (t 1/2) of approximately 8-10 d of innervated junctional receptors for up to 10 d after denervation before accelerating to a t 1/2 of approximately 3 d. The total junctional receptors, on the other hand, showed a progressive increase in degradation rate from a t 1/2 of 8-10 d to a t 1/2 of 1 d. To reconcile these earlier observations, the present study examines the degradation of new receptors inserted into the nmj after denervation. To avoid possible contamination of the data with postdenervation extrajunctional receptors, we used transmission electron microscope autoradiography to study only receptors located at the postjunctional fold of the nmj. We established that the new receptors inserted into denervated junctions have a t 1/2 of approximately 1 d, considerably faster than that of the original receptors and equivalent to that of postdenervation extrajunctional receptors. Both original and new receptors are interspersed at the top of the junctional folds. Thus, until all the original receptors are degraded, the postjunctional membrane contains two populations of AChRs that maintain a total steady-state site density but degrade at different rates

  14. Economic Loan Loss Provision and Expected Loss

    Directory of Open Access Journals (Sweden)

    Stefan Hlawatsch

    2010-10-01

    Full Text Available The intention of a loan loss provision is the anticipation of the loan's expected losses by adjusting the book value of the loan. Furthermore, this loan loss provision has to be compared to the expected loss according to Basel II and, in the case of a difference, liable equity has to be adjusted. This however assumes that the loan loss provision and the expected loss are based on a similar economic rationale, which is only valid conditionally in current loan loss provisioning methods according to IFRS. Therefore, differences between loan loss provisions and expected losses should only result from different approaches regarding the parameter estimation within each model and not due to different assumptions regarding the outcome of the model. The provisioning and accounting model developed in this paper overcomes the before-mentioned shortcomings and is consistent with an economic rationale of expected losses. Additionally, this model is based on a close-to-market valuation of the loan that is in favor of the basic idea of IFRS. Suggestions for changes in current accounting and capital requirement rules are provided.

  15. Radiation induced effects in the \\\\ATLAS Insertable B-Layer readout chip

    CERN Document Server

    The ATLAS collaboration

    2017-01-01

    The ATLAS Insertable B-Layer is the innermost pixel barrel layer of the ATLAS detector installed in 2014. During the first year of $pp$ collisions at $\\sqrt{s} = 13~{\\rm TeV}$ in 2015, an unusual increase was observed in the low voltage currents of the readout chips. This increase was found to be due to radiation damage to the chips. The dependence of the current on the total ionising dose and temperature has been studied using X-ray and proton beam sources, and will be presented in this note together with its possible parametrisation and operation guidelines for the detector.

  16. Characterization of large-insert DNA libraries from soil for environmental genomic studies of Archaea

    DEFF Research Database (Denmark)

    Treusch, Alexander H; Kletzin, Arnulf; Raddatz, Guenter

    2004-01-01

    Complex genomic libraries are increasingly being used to retrieve complete genes, operons or large genomic fragments directly from environmental samples, without the need to cultivate the respective microorganisms. We report on the construction of three large-insert fosmid libraries in total...... (approximately 1% each) have been captured in our libraries. The diversity of putative protein-encoding genes, as reflected by their distribution into different COG clusters, was comparable to that encoded in complete genomes of cultivated microorganisms. A huge variety of genomic fragments has been captured...

  17. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  18. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  19. Complications related to conventional self-expandable metal stent insertion and internal irradiation stent insertion in patients with advanced esophageal carcinoma: an analysis of 32 cases

    International Nuclear Information System (INIS)

    Xu Xingwen; Di Haiting; Zhu Jun; Shi Jian

    2011-01-01

    Objective: To compare the occurrence of complications between conventional self-expandable metal stent and internal irradiation stent insertion in treating patients with advanced esophageal carcinomas. Methods: A total of 32 patients with advanced esophageal carcinoma were randomly divided into irradiation stent group (n=15) and conventional stent group (n=17). Internal irradiation stent loaded with 125 I seeds was employed in patients of irradiation stent group, while conventional self-expandable metal stent was used in patients of conventional stent group. After the treatment, clinical follow-up was regularly conducted. Postoperative complications such as fever, severe chest pain, cough, esophageal perforation, pneumonia, hemorrhage, stent migration and restenosis, etc. were observed. Results: No significant difference in the occurrence of fever, severe chest pain, esophageal perforation and hemorrhage existed between the two groups (P>0.05). The difference in the occurrence of long-term complications such as stent migration or restenosis between the two groups was out statistically significant (P>0.05). However, the restenosis in irradiation stent group occurred obviously much later than that in conventional stent group. Conclusion: For the treatment of advanced esophageal carcinomas, the insertion of internal irradiation esophageal stent is safe. It dose not increase the incidence of postoperative complications. Therefore, it is worth popularizing this technique in clinical practice. (authors)

  20. Simulation study of a depth-encoding positron emission tomography detector inserting horizontal-striped glass between crystal layers

    Science.gov (United States)

    Kim, Kyu Bom; Choi, Yong; Kang, Jihoon

    2017-10-01

    This study introduces a depth-encoding positron emission tomography (PET) detector inserting a horizontal-striped glass between the pixilated scintillation crystal layers. This design allows light spreading so that scintillation photons can travel only through the X direction and allows alteration in the light distribution so that it can generate a unique pattern diagram of the two-dimensional (2-D) flood histogram that identifies depth position as well as X-Y position of γ-ray interaction. A Monte Carlo simulation was conducted for the assessment of the depth of interaction (DOI)-PET detector. The traced light distribution for each event was converted into the 2-D flood histogram. Light loss caused by inserting the horizontal-striped glass between the crystal layers was estimated. Applicable weighting factors were examined for each DOI-PET detector. No considerable degradation of light loss was observed. The flood histogram, without overlapping of each crystal position, can be generated for the DOI detector based on each crystal block by inserting the horizontal-striped glass with a thickness of >1 mm and the modified resistive charge division networks with applicable weighting factors. This study demonstrated that the proposed DOI-PET detector can extract the three-dimensional γ-ray interaction position without considerable performance degradations of the PET detector from the 2-D flood histogram.

  1. Experience with UIDC insertion outside of menses in Kenya ...

    African Journals Online (AJOL)

    %) or insertion outside of menses (6.9%), than the within menses (4.3%) groups. However, the differences were not statistically significant. Adjusted odds ratios for IUCD outside of menses and oligomenorrhoea/amenorrhea groups were 1.65 ...

  2. Prototype ISR Superconducting Quadrupole for the low beta insertion.

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The four coils are provisionally kept together by aluminium clamps while epoxy-glass bands are wrapped around them to form a number of spacer rings.Stainless steel spacers were then inserted between these rings and the yoke quadrants. The persons are Michel Bouvier(left) and Pierre Pugin. See also7702690X.

  3. Insertional mutagenesis using Tnt1 retrotransposon in potato

    Science.gov (United States)

    Potato is the third most important food crop in the world. However, genetics and genomics research of potato has lagged behind many major crop species due to its autotetraploidy and a highly heterogeneous genome. Insertional mutagenesis using T-DNA or transposable elements, which is available in sev...

  4. Otological Findings Ten Years after Myringotomy with Tympanostomy Tube Insertion

    Directory of Open Access Journals (Sweden)

    Ali Goljanian Tabrizi

    2011-01-01

    Full Text Available Introduction: To study the long-term complications of tympanostomy tube insertion in young children 10 years after surgery.   Materials and Methods: In September 2011, the medical records of all patients who had undergone myringotomy with tympanostomy tube insertion between February 2000 and March 2001 at the two general hospitals of Isfahan University of Medical Sciences were studied. Of the 98 patients who fulfilled the inclusion criteria, 82 patients agreed to participate and were enrolled in the study. The complications of the operation were evaluated in these patients.   Results: Of the 164 ears that were operated on, myringosclerosis was found in 17.1%, atrophy of the tympanic membrane in 1.2%, permanent perforation of the tympanic membrane in 0.6% and tympanic membrane atelectasis in 0.6%. None of the patients developed cholesteatoma as a complication of tympanostomy tube insertion.   Conclusion:  Considering the low risk of serious complications after 10 years, tympanostomy tube insertion is a safe and effective treatment option in the treatment of otitis media with effusion.

  5. High aspect ratio catalytic reactor and catalyst inserts therefor

    Science.gov (United States)

    Lin, Jiefeng; Kelly, Sean M.

    2018-04-10

    The present invention relates to high efficient tubular catalytic steam reforming reactor configured from about 0.2 inch to about 2 inch inside diameter high temperature metal alloy tube or pipe and loaded with a plurality of rolled catalyst inserts comprising metallic monoliths. The catalyst insert substrate is formed from a single metal foil without a central supporting structure in the form of a spiral monolith. The single metal foil is treated to have 3-dimensional surface features that provide mechanical support and establish open gas channels between each of the rolled layers. This unique geometry accelerates gas mixing and heat transfer and provides a high catalytic active surface area. The small diameter, high aspect ratio tubular catalytic steam reforming reactors loaded with rolled catalyst inserts can be arranged in a multi-pass non-vertical parallel configuration thermally coupled with a heat source to carry out steam reforming of hydrocarbon-containing feeds. The rolled catalyst inserts are self-supported on the reactor wall and enable efficient heat transfer from the reactor wall to the reactor interior, and lower pressure drop than known particulate catalysts. The heat source can be oxygen transport membrane reactors.

  6. Effects of Rotational Motion in Robotic Needle Insertion

    Science.gov (United States)

    Ramezanpour, H.; Yousefi, H.; Rezaei, M.; Rostami, M.

    2015-01-01

    Background Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations. Objective In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploited as a tissue sample under standard compression test with Zwick/Roell device employing 1-D axial load-cell. Methods Effects of rotational motion were studied by running needle insertion experiments in 5, 50 and 200 mm/min in two types of with or without rotational velocity of 50, 150 and 300 rpm. On further steps with deeper penetrations, friction force of the insertion procedure in needle shaft was acquired by a definite thickness of the tissue. Results Designed mechanism of fixture for providing different frequencies of rotational motion is available in this work. Results for comparison of different force graphs were also provided. Conclusion Derived force-displacement graphs showed a significant difference between two procedures; however, tissue bleeding and disorganized micro-structure would be among unavoidable results. PMID:26688800

  7. Angiotensin-converting enzyme insertion/deletion gene ...

    Indian Academy of Sciences (India)

    Angiotensin-converting enzyme insertion/deletion gene polymorphism in cystic fibrosis patients. Sabrine Oueslati Sondess Hadj Fredj Hajer Siala Amina Bibi Hajer Aloulou Lamia Boughamoura Khadija Boussetta Sihem Barsaoui Taieb Messaoud. Research Note Volume 95 Issue 1 March 2016 pp 193-196 ...

  8. The insertion/deletion polymorphism of angiotensin-converting ...

    African Journals Online (AJOL)

    The association between type 2 diabetes mellitus (T2DM) and essential hypertension (EH) is not well understood. Both conditions result from an interaction of multiple genetic (ethnic) and environmental (geographical) factors. One possible genetic determinant is the angiotensin-converting enzyme (ACE) insertion/deletion ...

  9. Root cause of incomplete control rod insertions at Westinghouse reactors

    International Nuclear Information System (INIS)

    Ray, S.

    1997-01-01

    Within the past year, incomplete RCCA insertions have been observed on high burnup fuel assemblies at two Westinghouse PWRs. Initial tests at the Wolf Creek site indicated that the direct cause of the incomplete insertions observed at Wolf Creek was excessive fuel assembly thimble tube distortion. Westinghouse committed to the NRC to perform a root cause analysis by the end of August, 1996. The root cause analysis process used by Westinghouse included testing at ten sites to obtain drag, growth and other characteristics of high burnup fuel assemblies. It also included testing at the Westinghouse hot cell of two of the Wolf Creek incomplete insertion assemblies. A mechanical model was developed to calculate the response of fuel assemblies when subjected to compressive loads. Detailed manufacturing reviews were conducted to determine if this was a manufacturing related issue. In addition, a review of available worldwide experience was performed. Based on the above, it was concluded that the thimble tube distortion observed on the Wolf Creek incomplete insertion assemblies was caused by unusual fuel assembly growth over and above what would typically be expected as a result of irradiation exposure. It was determined that the unusual growth component is a combination of growth due to oxide accumulation and accelerated growth, and would only be expected in high temperature plants on fuel assemblies that see long residence times and high power duties

  10. Case report: Awake insertion of the intubating laryngeal mask ...

    African Journals Online (AJOL)

    Case report: Awake insertion of the intubating laryngeal mask airway using dexmedetomidine sedation. P Dhar, TR Tedore. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.1080/22201173.2003.10872999.

  11. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    ) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical...

  12. Folding and insertion thermodynamics of the transmembrane WALP peptide

    NARCIS (Netherlands)

    Bereau, T.; Bennett, W.F.D.; Pfaendtner, J.; Deserno, M.; Karttunen, M.E.J.

    2015-01-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)$_n$(L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural

  13. Folding and insertion thermodynamics of the transmembrane WALP peptide

    NARCIS (Netherlands)

    Bereau, T.; Bennett, W.F.D. Drew; Pfaendtner, J.; Deserno, M.; Karttunen, M.

    2015-01-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA)n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural

  14. Folding and insertion thermodynamics of the transmembrane WALP peptide

    Energy Technology Data Exchange (ETDEWEB)

    Bereau, Tristan, E-mail: bereau@mpip-mainz.mpg.de [Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz (Germany); Bennett, W. F. Drew [Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1 (Canada); Pfaendtner, Jim [Department of Chemical Engineering, University of Washington, Seattle, Washington 98195 (United States); Deserno, Markus [Department of Physics, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 (United States); Karttunen, Mikko [Department of Mathematics and Computer Science & Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, MetaForum, 5600 MB Eindhoven (Netherlands)

    2015-12-28

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA){sub n} (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence.

  15. Folding and insertion thermodynamics of the transmembrane WALP peptide

    International Nuclear Information System (INIS)

    Bereau, Tristan; Bennett, W. F. Drew; Pfaendtner, Jim; Deserno, Markus; Karttunen, Mikko

    2015-01-01

    The anchor of most integral membrane proteins consists of one or several helices spanning the lipid bilayer. The WALP peptide, GWW(LA) n (L)WWA, is a common model helix to study the fundamentals of protein insertion and folding, as well as helix-helix association in the membrane. Its structural properties have been illuminated in a large number of experimental and simulation studies. In this combined coarse-grained and atomistic simulation study, we probe the thermodynamics of a single WALP peptide, focusing on both the insertion across the water-membrane interface, as well as folding in both water and a membrane. The potential of mean force characterizing the peptide’s insertion into the membrane shows qualitatively similar behavior across peptides and three force fields. However, the Martini force field exhibits a pronounced secondary minimum for an adsorbed interfacial state, which may even become the global minimum—in contrast to both atomistic simulations and the alternative PLUM force field. Even though the two coarse-grained models reproduce the free energy of insertion of individual amino acids side chains, they both underestimate its corresponding value for the full peptide (as compared with atomistic simulations), hinting at cooperative physics beyond the residue level. Folding of WALP in the two environments indicates the helix as the most stable structure, though with different relative stabilities and chain-length dependence

  16. Observations on rotating needle insertions using a brachytherapy robot

    International Nuclear Information System (INIS)

    Meltsner, M A; Ferrier, N J; Thomadsen, B R

    2007-01-01

    A robot designed for prostate brachytherapy implantations has the potential to greatly improve treatment success. Much of the research in robotic surgery focuses on measuring accuracy. However, there exist many factors that must be optimized before an analysis of needle placement accuracy can be determined. Some of these parameters include choice of the needle type, insertion velocity, usefulness of the rotating needle and rotation speed. These parameters may affect the force at which the needle interacts with the tissue. A reduction in force has been shown to decrease the compression of the prostate and potentially increase the accuracy of seed position. Rotating the needle as it is inserted may reduce frictional forces while increasing accuracy. However, needle rotations are considered to increase tissue damage due to the drilling nature of the insertion. We explore many of the factors involved in optimizing a brachytherapy robot, and the potential effects each parameter may have on the procedure. We also investigate the interaction of rotating needles in gel and suggest the rotate-cannula-only method of conical needle insertion to minimize any tissue damage while still maintaining the benefits of reduced force and increased accuracy

  17. Effects of lithium insertion on thermal conductivity of silicon nanowires

    International Nuclear Information System (INIS)

    Xu, Wen; Zhang, Gang; Li, Baowen

    2015-01-01

    Recently, silicon nanowires (SiNWs) have been applied as high-performance Li battery anodes, since they can overcome the pulverization and mechanical fracture during lithiation. Although thermal stability is one of the most important parameters that determine safety of Li batteries, thermal conductivity of SiNWs with Li insertion remains unclear. In this letter, using molecular dynamics simulations, we study room temperature thermal conductivity of SiNWs with Li insertion. It is found that compared with the pristine SiNW, there is as much as 60% reduction in thermal conductivity with 10% concentration of inserted Li atoms, while under the same impurity concentration the reduction in thermal conductivity of the mass-disordered SiNW is only 30%. With lattice dynamics calculations and normal mode decomposition, it is revealed that the phonon lifetimes in SiNWs decrease greatly due to strong scattering of phonons by vibrational modes of Li atoms, especially for those high frequency phonons. The observed strong phonon scattering phenomenon in Li-inserted SiNWs is similar to the phonon rattling effect. Our study serves as an exploration of thermal properties of SiNWs as Li battery anodes or weakly coupled with impurity atoms

  18. Insertion of lithium in Nb2O5

    International Nuclear Information System (INIS)

    Alves, M.C.M.; Bulhoes, L.O.S.; Castro, S.C.

    1990-01-01

    The electrode process during the reduction and oxidation of Nb sub(2) O sub(5) by cyclic voltametry was characterized. The surface analysis by X-ray photo electronic spectroscopy allowed characterize the surface processes, that happening during the insertion reaction. (author)

  19. Extra-anatomical complications of antegrade double-J insertion

    Directory of Open Access Journals (Sweden)

    A R Rao

    2011-01-01

    Full Text Available Introduction: Insertion of a double-J (JJ stent is a common procedure often carried out in the retrograde route by the urologists and the antegrade route by the radiologists. Reported complications include stent migration, encrustation, and fracture. Extra-anatomic placement of an antegrade JJ stent is a rare but infrequently recognized complication. Materials and Methods: We performed a retrospective audit of 165 antegrade JJ stent insertions performed over three consecutive years by a single interventional radiologist. All renal units were hydronephrotic at the time of nephrostomy. All procedures were performed under local anaesthetic with antibiotic prophylaxis. Results: Antegrade stent insertion was carried out simultaneously at the time of nephrostomy in 55 of the 165 cases (33%. The remainder were inserted at a mean of 2 weeks following decompression. In five (3% patients, who had delayed antegrade stenting following nephrostomy, the procedure was complicated by silent ureteric perforation and an extra-anatomic placement of the stent. These complications had delayed manifestations, which included two retroperitoneal abscesses, a pelvic urinoma, a case each of ureterorectal fistula, and ureterovaginal fistula. Risk factors for ureteric perforation include previous pelvic malignancy, pelvic surgery, pelvic radiation, and a history of ureteric manipulation. Conclusion: Antegrade ureteric JJ stenting is a procedure not without complications. Extra-anatomic placement of the antegrade stent is a hitherto the infrequently reported complication but needs a high index of suspicion to be diagnosed. Risk factors for ureteric perforation at the time of stent insertion have to be considered to prevent this potential complication.

  20. Customizable engineered blood vessels using 3D printed inserts.

    Science.gov (United States)

    Pinnock, Cameron B; Meier, Elizabeth M; Joshi, Neeraj N; Wu, Bin; Lam, Mai T

    2016-04-15

    Current techniques for tissue engineering blood vessels are not customizable for vascular size variation and vessel wall thickness. These critical parameters vary widely between the different arteries in the human body, and the ability to engineer vessels of varying sizes could increase capabilities for disease modeling and treatment options. We present an innovative method for producing customizable, tissue engineered, self-organizing vascular constructs by replicating a major structural component of blood vessels - the smooth muscle layer, or tunica media. We utilize a unique system combining 3D printed plate inserts to control construct size and shape, and cell sheets supported by a temporary fibrin hydrogel to encourage cellular self-organization into a tubular form resembling a natural artery. To form the vascular construct, 3D printed inserts are adhered to tissue culture plates, fibrin hydrogel is deposited around the inserts, and human aortic smooth muscle cells are then seeded atop the fibrin hydrogel. The gel, aided by the innate contractile properties of the smooth muscle cells, aggregates towards the center post insert, creating a tissue ring of smooth muscle cells. These rings are then stacked into the final tubular construct. Our methodology is robust, easily repeatable and allows for customization of cellular composition, vessel wall thickness, and length of the vessel construct merely by varying the size of the 3D printed inserts. This platform has potential for facilitating more accurate modeling of vascular pathology, serving as a drug discovery tool, or for vessel repair in disease treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Mismatch analysis of humeral nailing. Antegrade versus retrograde insertion

    International Nuclear Information System (INIS)

    Mahaisavariya, B.; Jiamwatthanachai, P.; Aroonjarattham, P.; Aroonjarattham, K.; Wongcumchang, M.; Sitthiseripratip, K.

    2011-01-01

    Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. The results showed: the diameter of the medullary canal averaged 7.9-13.8 mm; the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. (author)

  2. Increase in transmission loss of single panels by addition of mass inclusions to a poro-elastic layer: Experimental investigation

    Science.gov (United States)

    Kidner, M. R. F.; Fuller, C. R.; Gardner, B.

    2006-06-01

    The insertion loss of standard acoustic blankets can be significantly improved at low frequencies by the addition of randomly placed mass inclusions to the poro-elastic layers. The improvement is much greater than that due to the mass effect alone. The mass inclusions act as resonant systems and so increase the structure impedance. This paper reports the results of experimental investigations into this phenomenon. Increases in insertion loss of 15 dB in the 100 Hz third octave band are reported.

  3. Total parenteral nutrition - infants

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007239.htm Total parenteral nutrition - infants To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  4. Total parenteral nutrition

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000177.htm Total parenteral nutrition To use the sharing features on this page, please enable JavaScript. Total parenteral nutrition (TPN) is a method of feeding that bypasses ...

  5. Technique of total thyroidectomy

    International Nuclear Information System (INIS)

    Rao, R.S.

    1999-01-01

    It is essential to define the various surgical procedures that are carried out for carcinoma of the thyroid gland. They are thyroid gland, subtotal lobectomy, total thyroidectomy and near total thyroidectomy

  6. Total iron binding capacity

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003489.htm Total iron binding capacity To use the sharing features on this page, please enable JavaScript. Total iron binding capacity (TIBC) is a blood test to ...

  7. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    Science.gov (United States)

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Hair loss in women.

    Science.gov (United States)

    Harfmann, Katya L; Bechtel, Mark A

    2015-03-01

    Hair loss is a common cause of morbidity for many women. As a key member of the woman's health care team, the obstetrician/gynecologist may be the first person to evaluate the complaint of hair loss. Common types of nonscarring hair loss, including female pattern hair loss and telogen effluvium, may be diagnosed and managed by the obstetrician/gynecologist. A systematic approach to diagnosis and management of these common forms of hair loss is presented.

  9. Molecular evaluation of a novel missense mutation & an insertional truncating mutation in SUMF1 gene

    Directory of Open Access Journals (Sweden)

    Udhaya H Kotecha

    2014-01-01

    Full Text Available Background & objectives: Multiple suphphatase deficiency (MSD is an autosomal recessive disorder affecting the post translational activation of all enzymes of the sulphatase family. To date, approximately 30 different mutations have been identified in the causative gene, sulfatase modifying factor 1 (SUMF1. We describe here the mutation analysis of a case of MSD. Methods: The proband was a four year old boy with developmental delay followed by neuroregression. He had coarse facies, appendicular hypertonia, truncal ataxia and ichthyosis limited to both lower limbs. Radiographs showed dysostosis multiplex. Clinical suspicion of MSD was confirmed by enzyme analysis of four enzymes of the sulphatase group. Results: The patient was compound heterozygote for a c.451A>G (p.K151E substitution in exon 3 and a single base insertion mutation (c.690_691 InsT in exon 5 in the SUMF1 gene. The bioinformatic analysis of the missense mutation revealed no apparent effect on the overall structure. However, the mutated 151-amino acid residue was found to be adjacent to the substrate binding and the active site residues, thereby affecting the substrate binding and/or catalytic activity, resulting in almost complete loss of enzyme function. Conclusions: The two mutations identified in the present case were novel. This is perhaps the first report of an insertion mutation in SUMF1 causing premature truncation of the protein.

  10. Hidden blood loss after surgery for hip fracture

    DEFF Research Database (Denmark)

    Foss, N B; Kehlet, H

    2006-01-01

    Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number...

  11. Total well dominated trees

    DEFF Research Database (Denmark)

    Finbow, Arthur; Frendrup, Allan; Vestergaard, Preben D.

    cardinality then G is a total well dominated graph. In this paper we study composition and decomposition of total well dominated trees. By a reversible process we prove that any total well dominated tree can both be reduced to and constructed from a family of three small trees....

  12. Insertion sequence typing of Mycobacterium tuberculosis: characterization of a widespread subtype with a single copy of IS6110.

    Science.gov (United States)

    Fomukong, N G; Tang, T H; al-Maamary, S; Ibrahim, W A; Ramayah, S; Yates, M; Zainuddin, Z F; Dale, J W

    1994-12-01

    DNA fingerprinting with the insertion sequence IS6110 (also known as IS986) has become established as a major tool for investigating the spread of tuberculosis. Most strains of Mycobacterium tuberculosis have multiple copies of IS6110, but a small minority carry a single copy only. We have examined selected strains from Malaysia, Tanzania and Oman, in comparison with M. bovis isolates and BCG strains carrying one or two copies of IS6110. The insertion sequence appears to be present in the same position in all these strains, which suggests that in these organisms the element is defective in transposition and that the loss of transposability may have occurred at an early stage in the evolution of the M. tuberculosis complex.

  13. SUPRAPATELLAR VERSUS INFRAPATELLAR TIBIAL NAIL INSERTION- A PROSPECTIVE, RANDOMISED CONTROL PILOT STUDY

    Directory of Open Access Journals (Sweden)

    Sreekumar K

    2017-06-01

    Full Text Available BACKGROUND The standard for treating tibial shaft fractures are by intramedullary nails currently. After the procedure, one of the most frequent complication is knee pain, after consolidation even more chronically. Chronic knee pain can affect more than 50% of the cases, which was said by most authors. Alternative routes of inserting the nail is used, which includes by means of lateral patellar paratendon, medial patellar paratendon or transtendon to avoid the symptom. The aim of the study is to study the clinical and functional outcomes of suprapatellar versus infrapatellar tibial nail insertion. MATERIALS AND METHODS This is a prospective study, which was done from January 2014 to February 2015 and 50 patients who were skeletally mature were selected and randomised into IP and SP nail insertion groups. They were also given informed consent and only after they agreed, they were taken into the study. The technique of nail insertion was revealed to both the surgeon and the patient at that time. Exclusion Criteria- Pregnant women, patients with intra-articular involvement, periprosthetic fractures, nonunions, ipsilateral injuries, previous knee injuries, history of gout, rheumatoid, osteoarthritis, spinal injury and incarceration. SP insertion was performed percutaneously with the help of a special cannula system. RESULTS A total of 50 patients were selected in this study. 31 SP and 19 IP. 10 SP and 2 IP did not show up for follow up examinations, so only 38 patients were present for 12 months. At last, there were 21 SP and 17 IP patients. The time from when the index procedure was done to follow up was 14.6 months, i.e. it ranged from 12-28 months. 12 were males and 9 were females with suprapatellar, 9 were males and 8 were females in infrapatellar. Average age of suprapatellar was 42 and that of infrapatellar was 44. Open fractures were 5 and closed fractures were 33. VAS score was 0.78 in suprapatellar and 1.87 in infrapatellar. Data analysis

  14. Lesion insertion in the projection domain: Methods and initial results

    International Nuclear Information System (INIS)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-01-01

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  15. Lesion insertion in the projection domain: Methods and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  16. Lesion insertion in the projection domain: Methods and initial results.

    Science.gov (United States)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-12-01

    To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically acquired for the ACR

  17. Electrochemical insertion in solid media of alkali cations in carbonated host structures (polyacetylene, fullerene and graphite)

    International Nuclear Information System (INIS)

    Lemont, Sylvain

    1994-01-01

    This research thesis reports the investigation of electrochemical insertion of alkali cations in different host carbon containing structures (polyacetylene, fullerene, graphite). After a recall of the main characteristics of the three considered compounds, the author reports a bibliographical survey, describes the different compounds which can be used as solid electrolytes and explains the choice of the studied compounds with respect to their phase diagrams, ionic conductivity, electrochemical stability range. He describes the experimental methods, discusses the results obtained by intercalation of alkali cations (Li + , Na + , K + ) in polyacetylene. He discusses the electrochemical and structural results obtained on intercalation compounds of lithium and sodium ions in fullerene. The structures of several phases have been obtained by electron diffraction. Preliminary studies of electron energy loss spectrometry (EELS) are reported. The last part compares the results obtained on two types of graphite: pellets and spherules [fr

  18. Determination of generator losses and efficiency

    Directory of Open Access Journals (Sweden)

    Klasnić Ilija

    2015-01-01

    Full Text Available The paper presents the results of deriving by calculation the local and total losses of the generator as well as efficiency determination of the revitalised hydro-generator unit A4 in HPP 'Djerdap 1'. In order to determine the generator losses and generator efficiency, measurements are performed during the acceptance tests of revitalised aggregate A4 in HPP 'Djerdap 1'.

  19. Complications of Peripherally Inserted Central Venous Catheters: A Retrospective Cohort Study.

    Directory of Open Access Journals (Sweden)

    Paula Parás-Bravo

    Full Text Available The use of venous catheters is a widespread practice, especially in oncological and oncohematological units. The objective of this study was to evaluate the complications associated with peripherally inserted central catheters (PICCs in a cohort of patients.In this retrospective cohort study, we included all patient carrying PICCs (n = 603 inserted at our institute between October 2010 and December 2013. The main variables collected were medical diagnosis, catheter care, location, duration of catheterization, reasons for catheter removal, complications, and nursing care. Complications were classified as infection, thrombosis, phlebitis, migration, edema, and/or ecchymosis.All patients were treated according to the same "nursing care" protocol. The incidence rate of complications was two cases per 1000 days of catheter duration. The most relevant complications were infection and thrombosis, both with an incidence of 0.17 cases per 1000 days of the total catheterization period. The total average duration of catheterization was 170 days [SD 6.06]. Additionally to "end of treatment" (48.42% and "exitus", (22.53% the most frequent cause of removal was migration (displacement towards the exterior of the catheter (5.80%.PICCs are safe devices that allow the administration of long-term treatment and preserve the integrity of the venous system of the patient. Proper care of the catheter is very important to improve the quality life of patients with oncologic and hematologic conditions. Therefore, correct training of professionals and patients as well as following the latest scientific recommendations are particularly relevant.

  20. Cost and morbidity analysis of chest port insertion in adults: Outpatient clinic versus operating room placement.

    Science.gov (United States)

    Feo, Claudio F; Ginesu, Giorgio C; Bellini, Alessandro; Cherchi, Giuseppe; Scanu, Antonio M; Cossu, Maria Laura; Fancellu, Alessandro; Porcu, Alberto

    2017-09-01

    Totally implantable venous access devices (TIVADs) represent a convenient way for the administration of medications or nutrients. Traditionally, chest ports have been positioned by surgeons in the operating room, however there has been a transition over the years to port insertion by interventional radiologists in the radiology suite. The optimal method for chest port placement is still under debate. Data on all adult patients undergoing isolated chest port placement at our institution in a 12-year period were retrospectively reviewed. The aim of this cohort study was to compare cost and morbidity for chest port insertion in two different settings: outpatient clinic and operating room. Between 2003 and 2015 a total of 527 chest ports were placed in adult patients. Of them, 262 procedures were performed in the operating room and 265 procedures were undertaken in the outpatient clinic. Patient characteristics were similar and there was no significant difference in early (port was 1270 Euros in the operating room versus 620 Euros in the outpatient clinic. Our results suggest that chest ports can be safely placed in most patients under local anesthesia in the office setting without fluoroscopy or ultrasound guidance. Future randomized controlled studies may evaluate if surgeons or interventional radiologists should routinely perform these procedures in a dedicated office setting and reserve more sophisticated facilities only for patients at high risk of technical failure.