WorldWideScience

Sample records for total house cooling

  1. Housing maintenance of primary cooling pump I of Kartini reactor

    International Nuclear Information System (INIS)

    Agung Nugroho; Wahyu Imam W

    2013-01-01

    Housing maintenance of Primary Cooling Pump have been done with purpose to enhance capability of fluid block and stopping leakage. The procedures of modification are follow: Replace mechanical seal type Nock 560 – 1 ½'' by mechanical seal type Nock 560 - 38, modification gland plate/housing with to lathe the diameter of gland plate/housing from diameter of 54 mm to 60 mm, in size setting-up mechanical seal, alignment and then function test. The result of the modification are: mechanical seal has been installed, housing has been modified, and the leakage of primary cooling water has been repaired and operated properly. Conclusion of the maintenance are the primary cooling water pump is working well, because the primary cooling water is not leakage any more. (author)

  2. Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Olesen, Bjarne W.

    Present work addresses the heating, cooling and ventilation concerns of the Technical University of Denmark’s house, Fold, for Solar Decathlon Europe 2012. Various innovative approaches are investigated, namely, utilization of ground, photo-voltaic/thermal (PV/T) panels and phase change materials...... (PCM). The ground heat exchanger acts as the heat sink and heat source for cooling and heating seasons, respectively. Free cooling enables the same cooling effect to be delivered with 8% of the energy consumption of a representative chiller. The heating and cooling needs of the house are addressed...... by the embedded pipes which are coupled with the ground. Ventilation is mainly used to control the humidity and to remove sensory and chemical pollution. PV/T panels enable the house to be a “plus” energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively...

  3. Retrofitting the Southeast. The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W. [Steven Winter Associates, Inc., Norwalk, CT (United States); Shapiro, C. [Steven Winter Associates, Inc., Norwalk, CT (United States); Vijayakumar, G. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-02-01

    The Consortium for Advanced Residential Buildings research team has provided the technical engineering and building science support for a highly visible demonstration home that was unveiled at the National Association of Home Builders' International Builders Show on Feb. 9, 2012, in Orlando, FL. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This report describes the deep energy retrofit of the Cool Energy House (CEH), which began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  4. Retrofitting the Southeast: The Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

    2013-02-01

    The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

  5. Sustainable Heating, Cooling and Ventilation of a Plus-Energy House via Photovoltaic/Thermal Panels

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Skrupskelis, Martynas; Sevela, Pavel

    2014-01-01

    Present work addresses the HVAC and energy concerns of the Technical University of Denmark's house, Fold, for the competition Solar Decathlon Europe 2012. Various innovative solutions are investigated; photovoltaic/thermal (PV/T) panels, utilization of ground as a heat source/sink and phase change...... two separate systems. PV/T panels enable the house to perform as a plus-energy house. PV/T also yields to a solar fraction of 63% and 31% for Madrid and Copenhagen, respectively. The ground heat exchanger acts as the heat sink/source of the house. Free cooling enables the same cooling effect...

  6. Annual experimental results on heat and cool storage modes for natural energy autonomous house, HARBEMAN house; Shizen energy jiritsu house (HARBEMAN house) no chikunetsu chikurei mode no jissoku kekka

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T; Fujino, T; Suzuki, M [Tohoku University, Sendai (Japan)

    1997-11-25

    Outlined herein is performance of the solar system, followed for a year, installed in a solar house (HARBEMAN HOUSE) built in 1996 in City of Sendai. The house is equipped, on the roof, with a 30.42m{sup 2} wide solar collector on the south and sky radiator on the north. They are connected to a heat-insulated tank (31m{sup 3}) installed underground, storing hot or cool water which carries energy for heating/air-conditioning and hot water. The solar system operates in a long-term hot or cool water storage mode. In the hot water storage mode, the solar collector is connected to the underground main tank, where pumped-up water heated by solar heat is stored to be supplied as hot water. Heat collected is low during the December-February period, and recovered in March. In the cool water storage mode, the radiator is connected to the underground main tank, where pumped-up water is cooled by radiation and stored to be supplied to a fan coil unit in each room for air-conditioning. The recorded lowest temperature of water in the tank is 5.1degC. No air-conditioning load is observed, on account of the unseasonal weather. 3 refs., 10 figs., 2 tabs.

  7. IEA HPP Annex 32 - Economical heating and cooling systems for low-energy houses. State-of-the-art report Norway

    International Nuclear Information System (INIS)

    Stene, Joern

    2007-04-01

    Norway is a member of Annex 32, 'Economical heating and cooling systems for low-energy houses' (2006-2008), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 9 participating countries are Switzerland (Operating Agent), Austria, Canada, Germany, Japan, the Netherlands, Norway, Sweden and the USA. The Norwegian participation is financed by Enova SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. Task 1 of the project is a state-of the art analysis of the low-energy building market and heat pump technologies applied in this type of buildings. Heating demands for low-energy houses and passive houses in Norwegian climate are characterized as follows: The ratio of the annual heating demand for hot water heating and the total annual heating demand of the houses typically range from 40 to 85 percent, and the heating season for space heating and heating of ventilation air range from about 5-7 and 4-6 months per year for semi-detached houses and flats, respectively (Oslo climate). In comparison, the heating season for semi-detached houses and flats constructed in accordance with the Norwegian building codes of 1997 is 8 and 9 months, respectively. Development companies for residential properties, co-operative building societies as well as housing manufactures are now showing great interest in low-energy houses and passive houses. According to The Norwegian State Housing Bank, almost 10.000 residences with low-energy or passive house standard are now being planned, constructed or have been completed. The projects include single-family houses, semi-detached houses, row houses, block of flats and apartment buildings. The main focus in these projects has been on the architectural design, building construction and efficient ventilation systems, and less on the heating (and cooling) systems. The heat pump market in this market segment is regarded to be promising due to

  8. Water supply rates for recirculating evaporative cooling systems in poultry housing

    Science.gov (United States)

    Evaporative cooling (EC) is an important tool to reduce heat stress in animal housing systems. Expansion of ventilation capacity in tunnel ventilated poultry facilities has resulted in increased water demand for EC systems. As water resources become more limited and costly, proper planning and des...

  9. Comparisons of housing, bedding, and cooling options for dairy calves.

    Science.gov (United States)

    Hill, T M; Bateman, H G; Aldrich, J M; Schlotterbeck, R L

    2011-04-01

    Housing, bedding, and summer cooling were management options evaluated. Holstein calves (42±2 kg of body weight) initially 2 to 5 d of age were managed in southwest Ohio in poly hutches or wire mesh pens in a curtain-sided nursery with no supplemental heat. Calves were fed milk replacer (27% crude protein, 17% fat fed at 0.657 kg of dry matter per calf daily), starter (20% crude protein dry matter, textured, fed free-choice), and water (free-choice). Measurements were for 56 d. In trial 1, 28 calves per treatment were bedded with straw and housed in either hutches or nursery pens. This trial was conducted from September to March; the average temperature was 8°C and ranged from -17 to 31°C. In trial 2a, 16 calves per treatment were managed in nursery pens bedded with straw, in nursery pens bedded with sand, or in hutches bedded with sand. This trial was conducted from May to September; the average temperature was 21°C and ranged from 7 to 33°C. In trial 2b, 26 calves per treatment were housed in nursery pens and bedded with straw. This trial was conducted from May to September; the average temperature was 22°C and ranged from 8 to 34°C. One treatment was cooled with fans between 0800 and 1700 h and the other was not. Data were analyzed as repeated measures in a completely randomized block design by trial, with calf as the experimental unit. In trial 3, air in the nursery and calf hutches used above was sampled 35 d apart for calves aged 5 and 40 d. Air in individual hutches on 2 commercial farms was sampled for 5- and 40-d-old calves for 2 hutch types. Air in the multi-calf hutches was sampled for calves of 75 and 110 d of age. Bacterial concentrations of air samples were analyzed (log10) as odds ratios by Proc Logistic in SAS software (SAS Institute Inc., Cary, NC); differences were declared at Pbedding were greater and scouring was less than that in calves bedded with sand in the nursery or hutches. The relative humidity was greater in the hutches than in

  10. Performance analysis on natural energy autonomous house, HARBEMAN house; Shizen energy jiritsu house (HARBEMAN house) no simulation ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujino, T; Saito, T [Tohoku University, Sendai (Japan)

    1997-11-25

    Outlined herein are a procedure developed to simulate performance of an energy-autonomous (independent) solar house referred to as HARBEMAN HOUSE (HH) built in 1996 in City of Sendai, comparison between the simulated and observed results, and characteristics of the solar house. The house is equipped with a solar collector and sky radiator, both installed on the roof, the former facing south to collect solar energy and generate hot water whereas the latter facing north to radiate heat and generate cool water. Both are connected to an underground heat-insulated tank having a capacity of 31m{sup 3}, which stores hot or cool water to keep their conditions for extended periods. The solar system operates in heat- or cool-storage mode. In the heat-storage mode, quantity of heat stored increases, although at a slow rate, as tank capacity increases. In the cool-storage mode, on the other hand, quantity of cool stored increases in proportion to tank capacity. This is because solar energy is collected throughout the year whereas cooling by radiation is concentrated in early spring. Loss rate of heat stored increases as tank capacity increases, and the opposite trend is observed with cool stored. 12 refs., 7 figs., 2 tabs.

  11. Numerical simulation of a cooling tower coupled with heat pump system associated with single house using TRNSYS

    International Nuclear Information System (INIS)

    Chargui, R.; Sammouda, H.; Farhat, A.

    2013-01-01

    Highlights: • We simulate a cooling tower coupled with heat pump system and a single zone using TRNSYS. • We examine the temperature of water inside the cooling tower and inside the single zone. • We study the temporal evolution of the all parameters for 4500 h operation in winter in Tunisia. - Abstract: The industrial cooling towers in Tunisia meet difficulties due to the poor coordination between the utility and process sectors. In this study, we will consider especially the vapor recovery of the wastewater from the industrial activity in south Tunisia. By using the heat pump for high capacity, the problem for vapor from wastewater may be resolved. The coupling for the cooling tower and the heat pump system is investigated by TRNSYS software. The system of cooling tower is also associated with a single zone which is related to heat exchangers. An optimization model for the operation of a cooling water system was developed that accounts for a cooling tower, and a network of pipelines and heat exchangers for heating a single house. This work is based on numerical studies; the cooling tower performance, the single house, the heat pump and the heat exchanger that are simulated using TRNSYS model. The circulation of cooling water system is assured by a counter flow. The evaluations of the cooling tower geometry and performances are based on an adaptive version of Merkel’s method witch integrated in TRNSYS. The results of optimization using TRNSYS are validated by several theoretical and experimental studies

  12. Experimental and numerical CHT-investigations of cooling structures formed by lost cores in cast housings for optimal heat transfer

    Science.gov (United States)

    Kohlstädt, S.; Vynnycky, M.; Gebauer-Teichmann, A.

    2018-05-01

    This paper investigates the cooling performance of six different lost core designs for automotive cast houses with regard to their cooling efficiency. For this purpose, the conjugate heat transfer (CHT) solver, chtMultiregion, of the freely available CFD-toolbox OpenFOAM in its implementation of version 2.3.1 is used. The turbulence contribution to the Navier-Stokes equations is accounted for by using the RANS Menter SST k - ω model. The results are validated for one of the geometries by comparing with experimental data. Of the six investigated cooling structures, the one that forces the fluid flow to change its direction the most produces the lowest temperatures on the surface of the cast housing. This good cooling performance comes at the price of the highest pressure loss in the cooling fluid and hence increased pump power. It is also found that the relationship between performance and pressure drop is by no means generally linear. Slight changes in the design can lead to a structure which cools almost as well, but at much decreased pressure loss. Regarding the absolute values, the simulations showed that the designed cooling structures are suitable for handling the cooling requirements in the particular applications and that the maximum temperature stays below the critical limits of the electronic components.

  13. Innova House - Ottawa`s advanced house

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-01-31

    A pilot program was developed to provide the housing industry with a means to field test innovative technologies, products and building systems, and to evaluate their overall performance. Under Canada`s Advanced House Program, ten demonstration houses were designed, built and monitored. Ottawa`s Innova House, was one of the ten houses built for this program. The innovative energy saving features of the house included (1) air distribution with small diameter ducts and an electronically commutated motor, a 2.6 kW grid-connected photovoltaic system, (3) an energy recovery ventilator (ERV) with free-cooling mode, (4) a 94 per cent efficient integrated gas heating and hot water system, (5) airtight drywall construction, (6) CFC-free exterior insulation, (7) a natural-gas-engine heat pump for air conditioning, (8) a prototype sealed combustion gas range and clothes dryer, and (9) a manifold plumbing system to conserve water. It was designed to consume one half of the energy consumed in an R-2000 home and one third of the energy of a conventional house. Several of the mechanical elements did not perform at expected levels, (lower than expected efficiencies from the heating and cooling systems and a malfunctioning ERV), nevertheless, overall performance of the house was still very close to the targets. The construction and operation of the house was described. tabs., figs.

  14. Housing and energy in Denmark

    DEFF Research Database (Denmark)

    Marsh, Rob; Grupe Larsen, Vibeke; Kragh, Mikkel

    2010-01-01

      This paper examines the historical background, current context and future challenges for housing energy consumption in Denmark. There has been a radical transformation in housing energy consumption over the last 30 years, with an absolute reduction in heat consumption and a rapid growth...... in electricity consumption, reflecting wider technological and social transformations in the movement from an industrial to a knowledge based society. In new housing it is shown that electricity consumption now dominates the total primary energy consumption, and that as a consequence traditional heat saving...... paradigms are relatively less effective, and can result in overheating and rising electricity consumption. At the same time, climate change concerns show that rising temperatures will in the future result in a falling heat demand and increasing cooling demand in housing. With this background, a theoretical...

  15. Performance optimization of evacuated tube collector for solar cooling of a house in hot climate

    Science.gov (United States)

    Ghoneim, Adel A.

    2018-02-01

    Evacuating the space connecting cover and absorber significantly improves evacuated tube collector (ETC) performance. So, ETCs are progressively utilised all over the world. The main goal of current study is to explore ETC thermal efficiency in hot and severe climate like Kuwait weather conditions. A collector test facility was installed to record ETC thermal performance for one-year period. An extensively developed model for ETCs is presented, employing complete optical and thermal assessment. This study analyses separately optics and heat transfer in the evacuated tubes, allowing the analysis to be extended to different configurations. The predictions obtained are in agreement with experimental. The optimum collector parameters (collector tube length and diameter, mass flow rate and collector tilt angle) are determined. The present results indicate that the optimum tube length is 1.5 m, as at this length a significant improvement is achieved in efficiency for different tube diameters studied. Finally, the heat generated from ETCs is used for solar cooling of a house. Results of the simulation of cooling system indicate that an ETC of area 54 m2, tilt angle of 25° and storage tank volume of 2.1 m3 provides 80% of air-conditioning demand in a house located in Kuwait.

  16. Thermal indoor environment and energy consumption in a plus-energy house: cooling season measurements

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    indoor environment. For the energy consumption of the HVAC system, air-to-brine heat pump, mixing station and controller of the radiant floor, and the air handling unit were considered. The measurements were analyzed based on the achieved indoor environment category (according to EN 15251...... the floor cooling system) and increasing the ventilation rate provided a better thermal indoor environment but with increased energy consumption. The thermal indoor environment and energy performance of the house can be improved with decreased glazing area, increased thermal mass, installation of solar...

  17. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for new detached houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    R and D was made on solar systems for new detached houses, and design and construction of the experimental house were carried out. In system analysis, assessment of solar cooling/heating systems, improvement of a simulation model based on measured data, and improvement of cooling/heating systems by simulation were conducted. In development of equipment and materials for the experimental house, R and D was made on component materials, connection method and installation method on houses for vacuum glass tube type solar collectors, and a solar collector was fabricated. R and D was also made on combination of absorbent and coolant, drop type coolant generator and performance experiment for absorption refrigerators, and a refrigerator was fabricated. The experimental house is 2-stored RC wall construction of 79.94m{sup 2} in building area, and 133.26m{sup 2} in total floor area. From the viewpoint of energy saving, outside insulation, double window, and insulating rain shutter door were adopted. The newly developed vacuum glass tube type solar collector is applicable to existing houses because of its higher flexibility. (NEDO)

  18. Impact of Urban Heat Island under the Hanoi Master Plan 2030 on Cooling Loads in Residential Buildings

    Directory of Open Access Journals (Sweden)

    Tran Hoang Hai Nam

    2015-01-01

    Full Text Available This study aims to evaluate the influence of urban heat island (UHI under the Hanoi Master Plan 2030 on the energy consumption for space cooling in residential buildings. The weather conditions under the current and future status (master plan condition simulated in the previous study (Trihamdani et al., 2014 were used and cooling loads in all the residential buildings in Hanoi over the hottest month were estimated under the simulated current and future conditions by using the building simulation program, TRNSYS (v17. Three most typical housing types in the city were selected for the simulation. The cooling loads of respective housing types were obtained in each of the districts in Hanoi. The results show that the total cooling loads over June 2010 is approximately 683 Terajoule (TJ under the current status, but it is predicted to increase to 903 TJ under the master plan condition. The increment is largely due to the increase in number of households (203 TJ or 92%, but partially due to the increase in urban temperature, i.e. UHI effect (17 TJ or 8%. The increments in new built-up areas were found to be larger than those in existing built-up areas. The cooling load in apartment is approximately half of that in detached house, which is approximately half of that in row house. Moreover, it was seen that although sensible cooling loads increased with the increase in outdoor temperature, the latent cooling loads decreased due to the decrease in absolute humidity and the increase in air temperature.

  19. Fiscal 1976 Sunshine Project result report (Drawings). R and D on solar cooling/heating and hot water supply system (R and D on the system for apartment houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho zumenshu. Shugo jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    Working design was made on an apartment house for R and D on solar cooling/heating and hot water supply system, and its drawings were prepared. The design was made on the experimental medium-rise square pyramid apartment house (3- storied, 28 dwelling units, RC structure, 1,566.63m{sup 2} in building area, 2,309.05m{sup 2} in total floor area). The house was equipped with normal high-voltage receiving panel, indoor cubicle of 300kVA, common antenna TV, telephone piping, door chime, direct water supply system with individual meters, LPG gas piping with individual meters, central hot water supply system with individual meters, and central cooling/heating system with individual fan coil units. The exterior of the house was finished with asphalt-waterproofing normal concrete-finished roofs of 1/50 in gradient, epoxy system resin-coated exposed concrete exterior walls, Al sash slide pair-glass window and alumite-finished Al door openings, and foamed polystyrene insulation plates (60mm, 50mm and 50mm thick for roofs, floors and walls, respectively). (NEDO)

  20. Impact of urban heat island on cooling and environment: A demonstration project

    International Nuclear Information System (INIS)

    1993-04-01

    Landscaping has been shown in simulation and field studies to reduce building cooling loads by affecting microclimatic factors such as solar radiation, wind speed and air temperature. A demonstration project was undertaken to determine the magnitude of landscape induced changes in microclimate on building cooling loads and water use on four typical residences in Phoenix, Arizona. The energy use and microclimate of three unlandscaped (bare soil, rock mulch) and one landscaped (turf) home were monitored during summer 1990. In the fall, turf was placed around one of the unlandscaped houses, and shade trees planted on the west and south sides of another. Measurements continued during the summer of 1991. Total house air conditioning and selected appliance electrical data were collected, as well as inside and outside air temperatures. Detailed microclimate measurements were obtained for one to two week periods during both summers. Maximum reductions of hourly outside air temperatures of 1 to 1.5 degrees C, and of daily average air temperatures of up to 1 degrees C, resulted from the addition of turf landscaping. Addition of small trees to the south and west sides of another treatment did not have a noticeable effect on air temperature. Cooling load reductions of 10% to 17% were observed between years when well-watered turf landscaping was added to a house previously surrounded by bare soil. Addition of small trees to another bare landscape did not produce a detectable change in cooling load. The results of the study are used as input to a standard building energy use simulation model to predict landscape effects on cooling load and water usage for three typical houses, and to develop guidelines for use of energy efficient residential landscapes in Phoenix, Arizona

  1. Performance analysis on natural energy autonomous house (HARBEMAN house); Shizen energy jiritsu house (HARBEMAN house) ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Fujino, T; Saito, T [Tohoku University, Sendai (Japan)

    1996-10-27

    To reduce fossil fuel consumption and CO2 emission, this article introduces an actually constructed natural energy autonomous house. It has a solar collector on the south roof for hot water supply and a sky radiator on the north roof for cooling water supply. The sky radiator uses radiation cooling phenomena into the space by electromagnetic wave through the window of atmosphere. This house also has an insulated tank with a capacity of 31 m{sup 3} in its underground. In the long-term heat storage mode, the heat is collected through the solar radiation during the period from summer to spring and is stored in the underground water tank, to use it for heating and hot water supply in winter. The heat can be recovered from the garbage waste incinerator. A gas fired auxiliary boiler is used for the shortage. In the long-term heat regeneration mode, the heat is regenerated through the sky radiator during the period from spring to summer and is stored in the underground water tank, to use it for cooling in summer. For the shortage, the water is cooled using a heat pump operated by the midnight power. The insulating performance is improved by using the pair glass in windows and the glass wool in the walls. Rain water is collected in a tank with a capacity of 2 m{sup 3}, to use it for toilet water. Annual energy and water saving is equivalent to 600,000 yen. 10 refs., 10 figs., 2 tabs.

  2. Gas cooled traction drive inverter

    Science.gov (United States)

    Chinthavali, Madhu Sudhan

    2013-10-08

    The present invention provides a modular circuit card configuration for distributing heat among a plurality of circuit cards. Each circuit card includes a housing adapted to dissipate heat in response to gas flow over the housing. In one aspect, a gas-cooled inverter includes a plurality of inverter circuit cards, and a plurality of circuit card housings, each of which encloses one of the plurality of inverter cards.

  3. Effect of TOC [total organic carbon] on a PWR secondary cooling water system

    International Nuclear Information System (INIS)

    Gau, J.Y.; Oung, J.C.; Wang, T.Y.

    1989-01-01

    Increasing the amount of total organic carbon (TOC) during the wet layup of the steam generator was a problem in PWR nuclear power plant in Taiwan. The results of surveys of TOC in PWR secondary cooling water systems had shown that the impurity of hydrazine and the bacteria were the main reasons that increase TOC. These do not have a corrosion effect on Inconel 600 and carbon steel when the secondary cooling water containing the TOC is below 200 ppb. But the anaerobic bacteria from the steam generator in wet layup will increase corrosion rate of carbon steel and crevice corrosion of Inconel 600. (author)

  4. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cooling e...

  5. Leco. Thermo-active Ceilings & Free Cooling. Using free cooling in combination with thermo-active ceilings for integrated heating and cooling

    OpenAIRE

    Murphy, Mark Allen

    2010-01-01

    - The largest potential for decreasing green house gas emissions, and therewith mitigating the effects of global climate change, comes from improving energy efficiency. Through the integration of heating and cooling systems into building elements, such as the thermo-active ceiling, improvements in energy efficiency can be achieved. Utilizing thermal mass to buffer temperature variations and to level out peak loads reduces the instantaneous power demands and enables traditional cool...

  6. Classification of low energy houses in Danish Building Regulations

    DEFF Research Database (Denmark)

    Rose, Jørgen; Svendsen, Svend

    2005-01-01

    The new Danish Building Regulations (Building Regulations, 2005) introduces the total energy consumption, i.e. energy use for heating, ventilation, cooling and domestic hot water, for buildings as a measure for the energy efficiency of new buildings, i.e. moving away from the former U-value demands....... In addition to the minimum requirements for new buildings, the new Building Regulations also specify requirements for characterizing a building as either low energy building class 1 or low energy building class 2. This paper describes a type-house that is presently being built in Denmark. The type......-house easily meets the requirements for being categorized as a low energy building class 1, and the paper investigates how much U-values can be increased if the type-house were to fulfil the requirements for a low energy building class 2 or a building that just fulfils the minimum demands....

  7. The effects of landscaping on the residential cooling energy

    Science.gov (United States)

    Misni, A.

    2018-02-01

    This paper examines the effectiveness of landscaping on the air-conditioning energy saving of houses in a tropical environment. This case study involved looking at the construction and landscaping of three single-family houses in three sections of Shah Alam, Selangor, Malaysia. The houses ranged in age from 5 to 30 years old, which provided different examples of construction and maturity levels of the surrounding landscaping. Landscaping affects the thermal performance as well as on the air-conditioning energy of houses, in how it provides shade, channels wind, and evapotranspiration. While the construction of the three houses was similar, they were different in size and design, including their landscape design. These houses were chosen because they are representative of single-family tropical houses and landscaping styles in Malaysia since 30 years ago. Three houses were chosen; the 30-year-old house, the 10-year-old house, and the 5-year-old house. In a tropical country, landscaping is used to reduce the effects of the hot and humid climate. The houses spent 15-45% of the electricity cost on cooling. These results were influenced by human factors and the surrounding landscaping. Every type of vegetation, such as trees, grass, shrubs, groundcover, and turf, contributes to reducing air temperatures near the house and providing evaporative cooling.

  8. 9 CFR 3.79 - Mobile or traveling housing facilities.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Mobile or traveling housing facilities... Transportation of Nonhuman Primates 2 Facilities and Operating Standards § 3.79 Mobile or traveling housing facilities. (a) Heating, cooling, and temperature. Mobile or traveling housing facilities must be...

  9. 24 CFR 3280.714 - Appliances, cooling.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Appliances, cooling. 3280.714... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... accordance with ANSI Z21.40.1-1996, Gas Fired, Heat Activated, Air Conditioning and Heat Pump Appliances, and...

  10. Thermal hydraulic performance of naturally aspirated control rod housing assemblies

    International Nuclear Information System (INIS)

    Geiger, G.T.; Randolph, H.W.; Paik, I.K.; Foti, D.J.

    1992-01-01

    Savannah River Site reactors are comprised of heat generating fuel/target assemblies, control rods which regulate reactor power, and heavy water which acts as the coolant and as a moderator. The fuel/target assemblies are cooled by the downflow of heavy water while the control rods are cooled via upflow. Five control rods are grouped with two safety rods in seven-channel assemblies called septifoils. Under normal operating conditions, the reactor power level, radial shape flux and axial power flux are regulated by the positioning of the control rods. The control rods are solid rods of a lithium-aluminum alloy with an thin aluminum outer sheath. Lithium is a good absorber of neutrons and, thus control rod temperatures rise with reactor power. At conditions of sufficiently high reactor power and degraded coolant flow, the control rods could heat sufficiently to cause a metallurigical failure of the sheath leading to molten material coming in contact with water and the possibility of a steam explosion. An accident has been postulated as part of the analysis involving the safety upgrade of Savannah River Site reactors in which the housing is not seated on the pin. Coolant from the upflow pin would not be directed into the housing but, into the moderator space surrounding the housing. Only naturally aspirated cooling due to buoyancy effects would be available to cool the control rods and the coolant mass flow rate would drop significantly from its nominal value. In this study, the mechanisms and limits of cooling heated rods housed in an unseated septifoil are addressed. Experiments were conducted on a shortened, prototypic housing with electrically heated rods to gain an understanding of the phenomena governing the cooling in such a case and develop data which can be used to evaluate predictive models. These experiments are described, their results discussed, and the predictions of current models is presented

  11. Simulated Measurements of Cooling in Muon Ionization Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mohayai, Tanaz [IIT, Chicago; Rogers, Chris [Rutherford; Snopok, Pavel [Fermilab

    2016-06-01

    Cooled muon beams set the basis for the exploration of physics of flavour at a Neutrino Factory and for multi-TeV collisions at a Muon Collider. The international Muon Ionization Cooling Experiment (MICE) measures beam emittance before and after an ionization cooling cell and aims to demonstrate emittance reduction in muon beams. In the current MICE Step IV configuration, the MICE muon beam passes through low-Z absorber material for reducing its transverse emittance through ionization energy loss. Two scintillating fiber tracking detectors, housed in spectrometer solenoid modules upstream and downstream of the absorber are used for reconstructing position and momentum of individual muons for calculating transverse emittance reduction. However, due to existence of non-linear effects in beam optics, transverse emittance growth can be observed. Therefore, it is crucial to develop algorithms that are insensitive to this apparent emittance growth. We describe a different figure of merit for measuring muon cooling which is the direct measurement of the phase space density.

  12. Occupants’ Utilization of Natural Ventilation: A Study of Selected Terrace House Designs in Hot-humid Climate

    Directory of Open Access Journals (Sweden)

    Ibiyeye AI

    2015-05-01

    Full Text Available With increased time spent indoors and demand for enhanced comfort levels, energy consumption in homes is rising mostly for cooling, particularly in hot-humid regions. Natural ventilation is seen as an alternative to mechanical cooling as it is totally independent on energy and has been reported to be of high potential. However, little information is available on the utilization of natural ventilation in individual living spaces in different house designs. Therefore, this paper aims to investigate occupants’ utilization of natural ventilation in living spaces under different terrace house designs in hot-humid climate and also the relationship between the openings and occupants’ satisfaction with natural ventilation. Five (5 different terrace house types in Putrajaya, Malaysia with different opening design characteristics were selected for the study. A total of 298 households from these house types were surveyed and results show that occupants mostly open their windows during the daytime to capture breeze from outside despite the fact that they owned air-conditioners. In terms of occupants’ level of satisfaction with indoor ventilation when utilizing natural ventilation, majority rated neither satisfied nor unsatisfied. Further regression analysis reveals that this level of satisfaction is significantly related to opening sizes that are in accordance with the law, duration of opening windows and AC ownership. Findings from this study will shed more light on behavioural pattern of occupants of residential buildings towards natural ventilation provisions and highlight the importance of conforming to the law governing them.

  13. France uses the sun to cool its wine: the Banyuls winery solar cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2003-12-01

    The engineering consultancy Tecsol was asked to design a cooling system for a winery that would limit the variations in temperature during the year. Tecsol proposed a solar system. The total investment cost amounted to nearly two million French Francs (300,000 euros), almost double the cost of a conventional air-conditioning system. However, because the solar system reduced the conventional energy needs of the warehouse by about 40%, the French Agency for Environment and Energy Management (ADEME) provided a 37% subsidy for its rational use of energy. The 'Solarclim' solar installation has three functions: it produces hot water via 693 vacuum tube collectors with a useful surface of 130 m{sup 2}. The collectors are fixed to the roof of the wine cellar, which has an angle of 15 deg. Heat from the collectors is transferred to a 1000-litre hot water storage tank; it produces chilled water using a lithium bromide absorption plant with a nominal cooling capacity of 52 kW. This is housed in the technical premises on the lowest level and is used in conjunction with a 180 kW open-circuit cooling tower on the north facade; and the third function combines air-conditioning and, when necessary, space heating. The installation has been operating for 12 years with no particular problems. The equipment is environmentally friendly. The solar heat source avoids CO{sub 2} emissions, the absorption machine does not use CFCs or HCFCs, and the system is totally silent. (UK)

  14. A Poetry Coffee House: Creating a Cool Community of Writers

    Science.gov (United States)

    Ferguson, Kristen

    2017-01-01

    This article explores the sharing of writing through a coffee house--style poetry reading. Although this article focuses on a workshop and share activity used in a preservice teacher language arts and literacy course, it contains tips and ideas for implementing poetry coffee houses with elementary and secondary school students and preservice and…

  15. Study on indoor pollution by microbes grown in a solar house in Tokyo; Tokyo no solar house ni okeru kabi no jittai chosa

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, T; Aihara, M; Nakanishi, R; Ito, H [Ochanomizu University, Tokyo (Japan)

    1997-11-25

    Indoor pollution by microbes grown in a solar house is studied. It is a reinforced concrete building, having a total floor area of 260m{sup 2}, equipped with a flat type solar collector on the roof and a lighting window on the north, the former having an area of 16m{sup 2} and slanted at 60deg and the latter slanted at 60deg. It is also provided with a semi-underground room, to utilize heat capacity of soil for coolness in summer and warmness in winter. It provides a residential space throughout the year, with no artificial heating or air-conditioning system, naturally ventilated with air taken into the underground room and released out of a triangular shape on the roof. The building is also passively conditioned, being totally insulated with expanded polystyrene. Energy saving is the most important consideration for the solar house, slightly forcing the residents to exercise patience. For this reason, the solar house often smells musty, and pollution with microbes is quantitatively investigated. Microbes evolve more in the underground room than in the space above groun, because of higher humidity in the former. Accelerated ventilation or slight artificial air-conditioning will solve the trouble. 1 refs., 7 figs.

  16. Possible schemes for solar-powered air-conditioning in 2-storey terrace houses

    International Nuclear Information System (INIS)

    Chu, C.M.; Bono, A.; Prabhakar, A.

    2006-01-01

    Space cooling is required all year round in the tropics, and probably accounts for a considerable proportion of the cost of electricity. Solar radiation can be channeled into cooling by photovoltaic powered systems and through the relatively new adsorption cycle technology. Two-storey terrace housing appear to have the greatest potential of introducing solar-powered cooling to residential homes. There are two schemes to cool a two-storey terrace housing: 1) By spraying water down the roof a tank, circulated by a pump powered by PV panels on the roof or 2) By replacing the roof with solar hot water collectors and use adsorption cooling chillers to produce air-conditioning for the entire block of terrace houses. In scheme number 1, a preliminary, rough technical evaluation showed that it is possible to pump water to the roof to flow down as a thin film and cool the roof by evaporation to about 40 degree C from about 70 degree C if without water evaporation at the highest insolation rate of the day. Scheme number 2, which uses adsorption chilling technology, requires communal sharing of the air-conditioning facility. The effect of collecting solar heat using the roof is two fold: to absorb solar energy for producing hot water and reducing excess heat input to the house. Preliminary costing demonstrates that solar-powered air-conditioning is within reach of commercialisation, bearing in mind that bulk purchases will dramatically lower the price of a product

  17. The Paradox of Climate Change Mitigation and Adaptation in Danish Housing

    DEFF Research Database (Denmark)

    Marsh, Rob

    2012-01-01

    that reducing space heating with high levels of thermal insulation and passive solar energy results in overheating and a growing demand for cooling. Climate change is expected to reduce space heating and increase cooling de-mand in housing. An analysis of new build housing using passive solar energy......Climate change means that buildings must greatly reduce their energy consumption. It is however paradoxical that climate mitigation in Denmark has created negative energy and indoor climate problems in housing that may be made worse by climate change. A literature review has been carried out...... of housing schemes where climate mitigation was sought through reduced space heating demand, and it is shown that extensive problems with overheating exist. A theoretical study of regulative and design strategies for climate mitigation in new build housing has therefore been carried out, and it is shown...

  18. Approaches to Sustainable housing in Denmark and the international inspiration

    DEFF Research Database (Denmark)

    Knudstrup, Mary-Ann; Hansen, Hanne Tine Ring; Brunsgaard, Camilla

    years. This brings forward an increasing challenge to plan, design and build more sustainable buildings in order to be able to contribute to or reduce the use of energy for heating and cooling in new housing projects and thereby bring down the emission of CO2 when using less fossil fuel. This is crucial...... since carbon dioxide is one of the so called greenhouse gasses playing a major role in the overheating of the globe. Thus there is focus on reducing the CO2-level on a national and global level. This paper will look upon changes in interest and the different types of approaches to sustainable design...... of buildings and show examples of houses that can minimise the use of energy for heating and cooling in shape of detached houses, sky scrapers and some student's projects with high raised houses....

  19. Control Strategies for Ventilative Cooling of Overheated Houses

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Duer, Karsten

    2016-01-01

    -family house from the 1970s. The case study is renovated deeply and high- efficient (nZEB) creating two different scenarios. Mechanical ventilation system and manual control of the openings for both renovation scenarios cannot sufficiently eliminate the overheating risk indoors. The discharge coefficient...

  20. Sustainable Plus-energy Houses

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    This study is an outcome of Elforsk, project number 344-060, Bæredygtige Energi-Plus huse (Sustainable plus-energy houses). The focus of this report is to document the approach and the results of different analyses concerning a plus-energy, single family house. The house was designed...... for an international student competition, Solar Decathlon Europe 2012 and after the competition it was used as a full-scale experimental facility for one year. During this period, different heating and cooling strategies were tested and the performance of the house regarding the thermal indoor environment and energy...... was monitored. This report is structured as follows. Chapter 1 presents the project and briefly explains the different phases of the project. The details of the house’s construction and its HVAC system are explained in Chapter 2, along with the energy efficiency measures and innovations. Chapter 3 introduces...

  1. Passive cooling application in the north of Morocco

    International Nuclear Information System (INIS)

    Ahachad, M.; Draoui, A.; Belarbi, R.; Allard, F.

    2006-01-01

    According to the inter-professional union of the poultry farm sector in Morocco, the heat stress, during the last summer, has led to ones of heavy losses estimated of about ten million Euros at producers. In this paper the measures which could be used to reduce the fatal effect of heat stress phenomenon are presented. This is achieved by modeling and simulation of a typical poultry house in the north of Morocco. A case study was realized to show the influence of each parameter on the behaviour of the building. The most influential parameters are: ventilation shape, orientation, number of the occupants...etc. The evaporative cooling systems models were linked to thermal building software, TRNSYS, and the assessment of poultry house equipped with passive cooling systems will be presented. The simulations show that the heat stress phenomenon could be avoided. The experimental study of the poultry house equipped with a passive cooling system shows a decrease of temperature of the internal air from 5 to 9 degree centigrade, and an amelioration of quality of production, which is translated by an important decrease of mortality number and an increase of poultry weight.(Author)

  2. Sonoma House. Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Hoeschele, M. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles that promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  3. Sonoma House: Monitoring of the First U.S. Passive House Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

    2012-12-01

    The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

  4. Horizontal temperature distribution in a plus-energy house: cooling season measurements

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    The present study is concerned with the air and operative temperatures at different locations in a detached, one-story, single family, plus-energy house. The house was located in Denmark and it has been used as a full-scale experimental facility with heated dummies to simulate occupants living...

  5. Comprehensive energy and economic analyses on a zero energy house versus a conventional house

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, L. [School of Architecture, Tianjin University, Tianjin, 300072 (China); Hurt, R.; Correa, D.; Boehm, R. [Center for Energy Research, University of Nevada, Las Vegas, NV 89154 (United States)

    2009-09-15

    A zero energy house (ZEH) was built side by side with a baseline house in suburban Las Vegas. Actual energy performance measurements were carried out on the incorporated energy saving features and solar applications. The data show that a radiant barrier and a water-cooled air conditioner are major contributors to the energy savings, while an insulated floor slab and thermal mass walls are not effective for energy-conservation during cooling periods. Photovoltaic roof tiles produce enough green power to cover the use in the ZEH, and the solar water heater can reach a peak efficiency of 80%. The energy saving contribution of each incorporated component was obtained using Energy10 and eQUEST3.6 models, and then these codes were used for economic application evaluation. The two analysis codes yield similar results that compare well with the actual building performance data. Four items are clearly economically valuable for these applications: high performance windows, compact fluorescent lights, highly-insulated roofs and air conditioners with water-cooled condensers. PV tiles show a good financial return when rebates are considered. The Integrated Collector Storage (ICS) unit has a high efficiency but with a little higher thermal price. Thermal mass walls are too costly to have wide market appeal. (author)

  6. Pink-Beam, Highly-Accurate Compact Water Cooled Slits

    International Nuclear Information System (INIS)

    Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard; Waterman, Dave; Caletka, Dave; Steadman, Paul; Dhesi, Sarnjeet

    2007-01-01

    Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Element Analysis of the system are presented

  7. Energy efficient residential house wall system

    International Nuclear Information System (INIS)

    Aldawi, Fayez; Date, Abhijit; Alam, Firoz; Khan, Iftekhar; Alghamdi, Mohammed

    2013-01-01

    The energy consumption and greenhouse gas emission by the residential housing sector are considered to be one of the largest in economically developed countries. The larger energy consumption and greenhouse gas emission not only put additional pressure on finite fossil fuel resources but also cause global warming and climate change. Additionally, the residential housing sector will be consuming more energy as the house demand and average house floor area are progressively increasing. With currently used residential house wall systems, it is hard to reduce energy consumption for ongoing house space heating and cooling. A smart house wall envelope with optimal thermal masses and insulation materials is vital for reducing our increasing energy consumption. The major aim of this study is to investigate thermal performance and energy saving potential of a new house wall system for variable climate conditions. The thermal performance modelling was carried out using commercially developed software AccuRate ® . The findings indicate that a notable energy savings can be accomplished if a smart house wall system is used. -- Highlights: • Smart house wall system. • Thermal performance modelling and star energy rating. • Energy savings and greenhouse gas reduction

  8. Smart Houses

    Science.gov (United States)

    1987-01-01

    GWS takes plans for a new home and subjects them to intensive computerized analysis that does 10,000 calculations relative to expected heat loss and heat gain, then provides specifications designed specifically for each structure as to heating, cooling, ventilation and insulation. As construction progresses, GWS inspects the work of the electrical, plumbing and insulation contractors and installs its own Smart House Radiant Barrier. On completion of the home, GWS technicians use a machine that creates a vacuum in the house and enables computer calculation of the air exchanged, a measure of energy efficiency. Key factor is the radiant barrier, borrowed from the Apollo program. This is an adaptation of a highly effective aluminized heat shield as a radiation barrier holding in or keeping out heat, cold air and water vapor.

  9. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for apartment houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Shugo jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-03-01

    This report describes the fiscal 1976 research result on solar cooling/heating and hot water supply system for apartment houses. In the system research, comparative study was made on facility costs and operation costs per heat load between previous and solar cooling/heating and hot water supply systems for apartment houses. In the working design for apartment houses, various calculation necessary for start of work, and preparation of detail drawings and specifications were made. In development of solar collector, the test loop and collector were prepared using full-scale collector elements for medium-scale performance tests. In development of heat accumulator, inorganic hydrate was selected as heat storage material using latent heat for the confirmation test of basic physical properties. In development of solar cooling/heating equipment, the confirmation test of Rankine engine's performance, controllability and durability was made under real load. In addition, the refrigerator of nearly 20 tons of refrigeration driven by Rankine engine was fabricated, (NEDO)

  10. Energy Performance of Water-based and Air-based Cooling Systems in Plus-energy Housing

    DEFF Research Database (Denmark)

    Andersen, Mads E.; Schøtt, Jacob; Kazanci, Ongun Berk

    2016-01-01

    -space, and air-to-water heat pump vs. ground heat exchanger as cooling source) on the system energy performance were investigated while achieving the same thermal indoor conditions. The results show that the water-based floor cooling system performed better than the air-based cooling system in terms of energy...... energy use reductions. The coupling of radiant floor with the ground enables to obtain “free” cooling, although the brine pump power should be kept to a minimum to fully take advantage of this solution. By implementing a ground heat exchanger instead of the heat pump and use the crawl-space air as intake...... air an improvement of 37% was achieved. The cooling demand should be minimized in the design phase as a priority and then the resulting cooling load should be addressed with the most energy efficient cooling strategy. The floor cooling coupled with a ground heat exchanger was shown to be an effective...

  11. Satisfaction with housing and housing support for people with psychiatric disabilities.

    Science.gov (United States)

    Brolin, Rosita; Rask, Mikael; Syrén, Susanne; Baigi, Amir; Brunt, David Arthur

    2015-01-01

    The aim of this study was to investigate the degree of satisfaction with housing and housing support for people with psychiatric disabilities in Sweden. A total of 370 residents, in supported housing and in ordinary housing with housing support, completed a new questionnaire and reported a high degree of overall satisfaction, but many of them wanted to move somewhere else. Differences were found between the two different types of housing concerning satisfaction with housing support, social life and available choices. Security and privacy, as well as other's influence on the choice of residential area and dwelling proved to be important predictors for satisfaction.

  12. Improving indoor conditions of a Thai-style mushroom house by means of an evaporative cooler and continuous ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Thepa, S.; Kirtikara, K.; Hirunlabh, J.; Khedari, J. [King Mongkut' s Univ. of Technology, School of Energy and Materials, Bangkok (Thailand)

    1999-07-01

    The paper discusses the effect of an evaporative cooling process and continuous ventilation for improving the indoor conditions of a conventional Thai-style mushroom house. A numerical model describing the behaviour of the Thai-style mushroom house model was developed. It was validated by comparing its output with that of the experiment of a small model of a mushroom house. It was found that the combination of evaporative cooling and continuous ventilation reduced the temperature and increased the relative humidity of air inside a mushroom house that is suitable for growing Lentinus. (Author)

  13. Approaches to the Design of Sustainable Housing with Low CO2 Emission in Denmark

    DEFF Research Database (Denmark)

    Knudstrup, M.-A.; Ring Hansen, H.T.; Brunsgaard, C.

    2009-01-01

    places around the world in recent years. This has resulted in an increasing challenge in terms of the planning, design and building of more sustainable buildings in order to reduce the use of energy for heating and cooling in new housing projects by bringing down the emission of CO2 by reducing...... at the architectural and legislative changes in Denmark in relation to the increased political interest in the consequences of climate change. The article also discusses a survey of different types of approaches to the sustainable design of buildings and shows examples of new Danish housing projects that can minimise...... the use of energy for heating and cooling in the shape of detached houses, as well as a master thesis on high-rise houses....

  14. Endothermic technology for domestic houses

    International Nuclear Information System (INIS)

    Virk, G.S.

    2005-01-01

    The paper introduces the endothermic energy systems being developed for buildings. These use the concept of solar assisted heat pumps where thermal energy is harvested using large integrated solar collectors connected to energy stores. The low grade energy is upgraded using heat pumps to provide thermal energy effectively to a wide variety of applications for space heating and cooling and hot water. The domestic housing sector is focused upon here and a current EC funded project aimed at assessing the potential of the endothermic technology for providing the thermal energy for space heating and cooling and hot water is presented. (author)

  15. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [Steven Winter Associates, Inc., Norwalk, CT (United States); Puttagunta, S. [Steven Winter Associates, Inc., Norwalk, CT (United States)

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems,this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  16. Systems Evaluation at the Cool Energy House

    Energy Technology Data Exchange (ETDEWEB)

    J. Williamson and S. Puttagunta

    2013-09-01

    Steven Winter Associates, Inc. (SWA) monitored several advanced mechanical systems within a 2012 deep energy retrofitted home in the small Orlando suburb of Windermere, FL. This report provides performance results of one of the home's heat pump water heaters (HPWH) and the whole-house dehumidifier (WHD) over a six month period. In addition to assessing the energy performance of these systems, this study sought to quantify potential comfort improvements over traditional systems. This information is applicable to researchers, designers, plumbers, and HVAC contractors. Though builders and homeowners can find useful information within this report, the corresponding case studies are a likely better reference for this audience.

  17. Radon in houses

    International Nuclear Information System (INIS)

    Toohey, R.E.; Essling, M.A.; Markun, F.

    1985-01-01

    The purpose of this study is to determine the concentrations of 222 Rn and its short-lived daughter products in the air of single-family houses in the midwestern US. During the past year, more than 200 houses were added to the study, resulting in a total of more than 400 houses. So far, results are available for 270 of these houses, equally divided between the Chicago area and Bloomsburg, Pennsylvania. 6 refs

  18. Inverter power module with distributed support for direct substrate cooling

    Science.gov (United States)

    Miller, David Harold [San Pedro, CA; Korich, Mark D [Chino Hills, CA; Ward, Terence G [Redondo Beach, CA; Mann, Brooks S [Redondo Beach, CA

    2012-08-21

    Systems and/or methods are provided for an inverter power module with distributed support for direct substrate cooling. An inverter module comprises a power electronic substrate. A first support frame is adapted to house the power electronic substrate and has a first region adapted to allow direct cooling of the power electronic substrate. A gasket is interposed between the power electronic substrate and the first support frame. The gasket is configured to provide a seal between the first region and the power electronic substrate. A second support frame is adapted to house the power electronic substrate and joined to the first support frame to form the seal.

  19. Cooled spool piston compressor

    Science.gov (United States)

    Morris, Brian G. (Inventor)

    1993-01-01

    A hydraulically powered gas compressor receives low pressure gas and outputs a high pressure gas. The housing of the compressor defines a cylinder with a center chamber having a cross-sectional area less than the cross-sectional area of a left end chamber and a right end chamber, and a spool-type piston assembly is movable within the cylinder and includes a left end closure, a right end closure, and a center body that are in sealing engagement with the respective cylinder walls as the piston reciprocates. First and second annual compression chambers are provided between the piston enclosures and center housing portion of the compressor, thereby minimizing the spacing between the core gas and a cooled surface of the compressor. Restricted flow passageways are provided in the piston closure members and a path is provided in the central body of the piston assembly, such that hydraulic fluid flows through the piston assembly to cool the piston assembly during its operation. The compressor of the present invention may be easily adapted for a particular application, and is capable of generating high gas pressures while maintaining both the compressed gas and the compressor components within acceptable temperature limits.

  20. Life Cycle Inventory & Assessment Report: Cooling of Manure, Applied to Fattening Pigs Slurry, Denmark

    DEFF Research Database (Denmark)

    Wesnæs, Marianne; Hamelin, Lorie; Wenzel, Henrik

    of heat for e.g. heating the housing units for the pigs. The environmental consequences of the technology are not straightforward: What are the environmental advantages and disadvantages of applying manure cooling in the housing units for fattening pigs? The environmental impacts has been evaluated along......The Manure Cooling Technology reduces ammonia emissions in the housing units, which leads to a higher N content in the manure (which might increase nitrate leaching). The technology is based on a heat pump, which requires electricity; however, it also produces heat that can replace other sources...... as part of Work Package 5 on Assessing Sustainability of Manure Technology Chains in the project Baltic Manure....

  1. Turbine airfoil with laterally extending snubber having internal cooling system

    Science.gov (United States)

    Scribner, Carmen Andrew; Messmann, Stephen John; Marsh, Jan H.

    2016-09-06

    A turbine airfoil usable in a turbine engine and having at least one snubber with a snubber cooling system positioned therein and in communication with an airfoil cooling system is disclosed. The snubber may extend from the outer housing of the airfoil toward an adjacent turbine airfoil positioned within a row of airfoils. The snubber cooling system may include an inner cooling channel separated from an outer cooling channel by an inner wall. The inner wall may include a plurality of impingement cooling orifices that direct impingement fluid against an outer wall defining the outer cooling channel. In one embodiment, the cooling fluids may be exhausted from the snubber, and in another embodiment, the cooling fluids may be returned to the airfoil cooling system. Flow guides may be positioned in the outer cooling channel, which may reduce cross-flow by the impingement orifices, thereby increasing effectiveness.

  2. Thermal, Economic and Environmental Analysis of a Low-Cost House in Alice, South Africa

    Directory of Open Access Journals (Sweden)

    Overen Ochuko Kelvin

    2017-03-01

    Full Text Available Indoor and outdoor temperature variation results in heat transfer between the inner and outer space of a house, subsequently drifting the indoor temperature out of the thermal comfort zone. This leads to occupants spending a significant amount of their income on space heating and cooling to achieve thermal comfort. The aim of this study is to analyze the thermal, economic and environmental impact of a low-cost house. A low-cost house located in Golf Course, Alice was used as a case study. The outdoor and indoor weather conditions of the house were monitored for periods covering summer and winter seasons. To maintain indoor thermal comfort, 3412.57 kWh of heating and 3214.75 kWh cooling energy were required in winter and summer seasons, respectively. At a rate of 1 ZAR equal to 13.34 USD and 29.39 c/kWh, the energy consumption results in $1003.02 worth of heating energy in winter and $944.88 of cooling energy in summer. In both seasons, to supply the equivalent amount of thermal energy used in the house from a coal-fired power plant, 9.65 ton of CO2, 81.71 kg of SO2 and 39.50 kg of NO2 gases will be emitted into the atmosphere. Promoting and enforcing energy efficient design in low-cost housing will not only bring about energy savings, but will also provide a year-round indoor thermal comfort.

  3. Windows in Low Energy Houses. Size Matters

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Mari-Louise

    2004-06-01

    A generally accepted way of building passive houses has been to have small windows facing north and a large glass facade to the south. This is to minimize losses on the north side while gaining as much solar heat as possible on the south. In spring 2001, twenty terraced houses were built outside Goeteborg partly in this way. The indoor temperature is kept at a comfortable level by passive methods, using solar gains and internal gains from household appliances and occupants. Heat losses are very low, since the building envelope is well insulated and since modern coated triple-glazed windows have been installed. The purpose of this work is to investigate how decreasing the window size facing south and increasing the window size facing north in low energy houses will influence the energy consumption and maximum power needed to keep the indoor temperature between 23 and 26 deg C. Different climates and orientations have been investigated and so have the influence of occupancy and window type. A dynamic building simulation tool, DEROB, has been used and the simulations indicate an extremely low energy demand for the houses. The results show that the size of the energy efficient windows does not have a major influence on the heating demand in winter, but is of relevant signification looking at the cooling need in summer. This indicates that instead of the traditional technique of building passive houses it is possible to enlarge the window area facing north and get better lighting conditions. To decrease the energy need for cooling, there is an optimal window size facing south that is smaller than the original size of the investigated buildings.

  4. Ideal energy self-sufficient bioclimatic house

    Energy Technology Data Exchange (ETDEWEB)

    Talamo, C.

    1990-04-01

    This paper points out some of the interesting architectural features of a conceptual house being designed to be self-sufficient relative to the use of conventional energy sources. Brief notes are given on the following special design characteristics: the house's orientation and form - essentially a V - shaped two storey design with an orientation such as to maximize the surface area exposed to winter insolation; its special low emissivity glazing equipped with nightfall insulating screens; the adoption of maximized insulation, in which case cost benefits were assessed based on amortization over the entire life span of the house; hybrid space heating and ventilation systems involving the integration of pumps and ventilators for air circulation, and the use of a varied mix of active and passive solar heating and cooling systems.

  5. X-ray diffraction device comprising cooling medium connections provided on the x-ray tube

    NARCIS (Netherlands)

    1996-01-01

    An X-ray diffraction device comprises a water-cooled X-ray tube which exhibits a line focus as well as, after rotation through 90 DEG , a point focus. Contrary to customary X-ray tubes, the cooling water is not supplied via the housing (12) in which the X-ray tube is mounted, but the cooling water

  6. Guidebook for introduction of snow/ice cool energy; Seppyo reinetsu energy donyu guide book

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-03-01

    For the purpose of contributing to the promotion of introduction of snow/ice cool energy in cold snowing areas, investigational study was made such as analysis of samples of introduction of snow/ice cool energy and effects. In the survey, for three kinds of the snow/ice cool energy system, that is, snow air-conditioning/refrigerating system, ice shelter system and artificial frozen soil system (heat pipe), each of the samples of introduction was outlined, and the effect of introduction by system was analyzed. As to the evaluation of economical efficiency, constructed were 12 kinds of the snow/ice cool energy spread type model system by the demand facilities including distribution facilities of perishable foods and shopping centers, hospitals and multiple dwelling houses, commercial/residential facilities such as office buildings, and industrial facilities such as food factories. These was comparatively studied with the electric air-conditioning system. As a result, it was made clear that the total cost was approximately a half times as high as that of the electric air-conditioning system, but the system had great incentive effect, supported by subsidies for the initial investment. (NEDO)

  7. Analysis and Comparison of Overheating Indices in Energy Renovated Houses

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Duer, Karsten

    2015-01-01

    The scientific literature offers a number of methods for assessing the likelihood of overheating in buildings. The paper calculates eight well-documented indices for four representative family houses, from moderate and temperate climates, under different renovation processes (66 variants), with t......The scientific literature offers a number of methods for assessing the likelihood of overheating in buildings. The paper calculates eight well-documented indices for four representative family houses, from moderate and temperate climates, under different renovation processes (66 variants......), with the use of multi-zone energy software. In two out of four cases, the calculation included passive cooling measures for optimization purposes (shading, ventilative cooling). The analysis shows strong correlations between different methods-indices originating from the same comfort model theory independently...

  8. Solar cooling - Economical assessment and CO{sub 2} balance; Solar Cooling. Oekonomische Bewertung und CO{sub 2} Bilanzierung

    Energy Technology Data Exchange (ETDEWEB)

    Gantenbein, P.; Machein, T.; Frank, E.

    2010-07-01

    This short, illustrated final report discusses how thermally-driven sorption chiller systems can help meet future cooling needs in houses and workplaces. Increasing global temperatures are commented on and their influence on space heating and cooling is discussed. The modelling of a single-family home, an office building and an industrial building is described. Three cooling systems are taken into consideration: a single-stage LiBr-H{sub 2}O absorber machine using solar energy from vacuum-pipe collectors, a compressor refrigeration system with a heating function powered by photovoltaics and a compressor system run on mains electricity. The simulations were carried out for locations in three different climate zones, in Lugano, Switzerland, Athens, Greece and Dubai, United Arab Emirates. The results are commented on.

  9. Comparison of DOE-2 with measurements in the Pala Test houses

    Energy Technology Data Exchange (ETDEWEB)

    Meldem, R.; Winkelmann, F.

    1995-07-01

    The predictions of the DOE-2 program for building energy analysis have been compared with measurements in the Pala test houses near San Diego. This work is part of the California Institute for Energy Efficiency {open_quotes}Alternatives to Compressor Cooling in California Transition Zones{close_quotes} project in which DOE-2 is being used for parametric analysis of cooling strategies that reduce peak electrical power in hot, dry climates. To establish the validity of DOE-2 for this kind of analysis the program was compared with room air temperature measurements in a {open_quotes}low-mass{close_quotes} house with conventional insulated study wall construction and a {open_quotes}high-mass{close_quotes} house with insulated concrete walls. To test different aspects of the DOE-2 calculation, four different unconditioned thermal configurations of these houses were considered: unshaded windows, shaded windows, white exterior surfaces, and forced night ventilation. In all cases DOE-2 agreed well with the air temperature measurements, with a mean deviation between simulation and measurement ranging from 0.2 to 1.0 K depending on configuration and type of house. Using a development version of DOE-2 comparisons with inside surface temperature measurements were also made. These comparisons also showed good agreement.

  10. Housing Wealth and Consumption: A Micro Panel Study

    DEFF Research Database (Denmark)

    Browning, Martin; Gørtz, Mette; Leth-Petersen, Søren

    2013-01-01

    find little evidence of a housing wealth effect on consumption: unexpected innovations to house prices are uncorrelated with changes in total expenditure at the household level. A reform in 1992 allowed – for the first time - house owners to use their housing equity as collateral for consumption loans....... We find that young house owners likely to be affected by credit constraints react to house price changes after 1993. Our findings suggest that house prices impact total expenditure through improved collateral rather than directly through wealth....

  11. Cooling your home naturally

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    This fact sheet describes some alternatives to air conditioning which are common sense suggestions and low-cost retrofit options to cool a house. It first describes how to reflect heat away from roofs, walls, and windows. Blocking heat by using insulation or shading are described. The publication then discusses removing built-up heat, reducing heat-generating sources, and saving energy by selecting energy efficient retrofit appliances. A resource list is provided for further information.

  12. Stacking with stochastic cooling

    Energy Technology Data Exchange (ETDEWEB)

    Caspers, Fritz E-mail: Fritz.Caspers@cern.ch; Moehl, Dieter

    2004-10-11

    Accumulation of large stacks of antiprotons or ions with the aid of stochastic cooling is more delicate than cooling a constant intensity beam. Basically the difficulty stems from the fact that the optimized gain and the cooling rate are inversely proportional to the number of particles 'seen' by the cooling system. Therefore, to maintain fast stacking, the newly injected batch has to be strongly 'protected' from the Schottky noise of the stack. Vice versa the stack has to be efficiently 'shielded' against the high gain cooling system for the injected beam. In the antiproton accumulators with stacking ratios up to 10{sup 5} the problem is solved by radial separation of the injection and the stack orbits in a region of large dispersion. An array of several tapered cooling systems with a matched gain profile provides a continuous particle flux towards the high-density stack core. Shielding of the different systems from each other is obtained both through the spatial separation and via the revolution frequencies (filters). In the 'old AA', where the antiproton collection and stacking was done in one single ring, the injected beam was further shielded during cooling by means of a movable shutter. The complexity of these systems is very high. For more modest stacking ratios, one might use azimuthal rather than radial separation of stack and injected beam. Schematically half of the circumference would be used to accept and cool new beam and the remainder to house the stack. Fast gating is then required between the high gain cooling of the injected beam and the low gain stack cooling. RF-gymnastics are used to merge the pre-cooled batch with the stack, to re-create free space for the next injection, and to capture the new batch. This scheme is less demanding for the storage ring lattice, but at the expense of some reduction in stacking rate. The talk reviews the 'radial' separation schemes and also gives some

  13. Experimental StudyHigh Altitude Forced Convective Cooling of Electromechanical Actuation Systems

    Science.gov (United States)

    2016-01-01

    34 Massachusetts Institute of Technology , 1989. [3] FedBizOps.Gov, " Integrated Vehicle Energy Technology (INVENT) Development Program for the 6th...AFRL-RQ-WP-TR-2016-0043 EXPERIMENTAL STUDY—HIGH ALTITUDE FORCED CONVECTIVE COOLING OF ELECTROMECHANICAL ACTUATION SYSTEMS Evan M. Racine...TITLE AND SUBTITLE EXPERIMENTAL STUDY—HIGH ALTITUDE FORCED CONVECTIVE COOLING OF ELECTROMECHANICAL ACTUATION SYSTEMS 5a. CONTRACT NUMBER In-house

  14. Prevention of strong stench for stocked radioisotope sewerage using total water treatment agent for small-sized cooling towers

    International Nuclear Information System (INIS)

    Aoki, Katsumi; Nishimaki, Toshiyuki; Furuse, Yuko; Shinozuka, Akiko

    1996-01-01

    In general, the sewerage at radioisotope laboratories has very strong stench. We treated the sewerage with a total water treatment agent (Tachileslegi, Nippon Nouyaku Co., Ltd. ) that is widely used for prevention of slime, scale, corrosion in cooling towers. As the result, the stench was decreased to about two thirds to that of control estimated by odor-test. (author)

  15. How Well Are We Housed? 3. Blacks.

    Science.gov (United States)

    Limmer, Ruth

    Blacks are housed poorly compared to the total American population. Black housing suffers frequently from deficiencies in every category except heating and electricity. It is estimated that 37% of blacks, but only 20% of the total population, need to spend more than a quarter of their cash incomes to live in unflawed, uncrowded housing. The…

  16. Beyond nearly zero-energy buildings: Experimental investigation of the thermal indoor environment and energy performance of a single-family house designed for plus-energy targets

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2016-01-01

    A detached, one-story, single-family house in Denmark was operated with different heating and cooling strategies for 1 year. The strategies compared during the heating season were floor heating without ventilation, floor heating supplemented by warm air heating (ventilation system), and floor...... but it was not possible to reach the intended operative temperature when the outside temperatures were very low. During the cooling season, the cooling demand was high and overheating was a problem. Although the house was designed as a plus-energy house, it did not perform as one under the Danish climate conditions...

  17. Examing the prospective of implementing passive house standards in providing sustainable schools

    Science.gov (United States)

    Suhaili, Wan Farhani; Shahrill, Masitah

    2018-04-01

    This study examines the potential of implementing the passive house standards to reduce energy consumption on school buildings in Brunei. Furthermore, it investigates whether sustainable school buildings make business sense to the government. To do this, conventional and Passive House primary school buildings are compared in terms of their performances using the Passive House Planning Package as well as the Ecotect environmental analysis tool. The findings indicated that by replacing lower U-values building fabrics brought a significantly reduction in the cooling demand of 54%. Whereas, Ecotect models have demonstrated that the heating and cooling loads have tremendously reduced to 75% by reorienting the location of the building to south elevation and by replacing the building fabrics with a lower U-values. These findings were then evaluated with a cost benefit analysis that proved to save cost energy annually from air-conditioning usage from a typical primary school with eight years of pay back period.

  18. Methods and apparatus for cooling electronics

    Science.gov (United States)

    Hall, Shawn Anthony; Kopcsay, Gerard Vincent

    2014-12-02

    Methods and apparatus are provided for choosing an energy-efficient coolant temperature for electronics by considering the temperature dependence of the electronics' power dissipation. This dependence is explicitly considered in selecting the coolant temperature T.sub.0 that is sent to the equipment. To minimize power consumption P.sub.Total for the entire system, where P.sub.Total=P.sub.0+P.sub.Cool is the sum of the electronic equipment's power consumption P.sub.0 plus the cooling equipment's power consumption P.sub.Cool, P.sub.Total is obtained experimentally, by measuring P.sub.0 and P.sub.Cool, as a function of three parameters: coolant temperature T.sub.0; weather-related temperature T.sub.3 that affects the performance of free-cooling equipment; and computational state C of the electronic equipment, which affects the temperature dependence of its power consumption. This experiment provides, for each possible combination of T.sub.3 and C, the value T.sub.0* of T.sub.0 that minimizes P.sub.Total. During operation, for any combination of T.sub.3 and C that occurs, the corresponding optimal coolant temperature T.sub.0* is selected, and the cooling equipment is commanded to produce it.

  19. Modelling of phase change materials in the Toronto SUI net zero energy house using TRNSYS

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, O.; Fung, A.; Zhang, D. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering

    2008-08-15

    In the context of building applications, phase change materials (PCM), can be defined as any heat storage material that can absorb a large amount of thermal energy while undergoing a change in phase, such as from a solid to a liquid phase. The incorporation of PCM into the building envelope can enhance occupant comfort through the reduction of indoor temperature fluctuations. It has also been shown to cause a decrease in the overall energy consumption associated with the heating and cooling of buildings. This paper extended the analysis of the impact of using PCM, which has traditionally focused on homes of ordinary construction, to incorporate low to zero energy homes using a model of the Toronto net zero energy house developed in TRNSYS. The paper provided a description of the TRNSYS model/methodology, with reference to the wall layer used in the net zero energy house, and model of the layout of the net zero energy house in TRYNSYS. The TRYNSYS/type 204 PCM component was also presented along with the simulation results in terms of the temperature profile of the third floor of the net zero energy house on a typical winter day with varying PCM concentrations; the temperature profile of the third floor of the net zero energy house on a typical summer day with varying PCM concentrations; yearly heating/cooling load requirements of the net zero energy house for a variety of thermal mass used; temperature profile of the third floor of the net zero energy house on a typical summer day when PCM and concrete slab was used; yearly temperature profile of the third floor of the net zero energy house, illustrating the impact of using PCM; and the yearly heating/cooling load of the net zero energy house as the concentration of PCM was varied. It was concluded that the use of building integrated PCM can reduce temperature fluctuations considerably in the summer but only slightly in the winter. 16 refs., 1 tab., 8 figs.

  20. Energy saving house utilizing photovoltaic system. 3; Taiyoko hatsuden wo donyushita sho energy jutaku. 3

    Energy Technology Data Exchange (ETDEWEB)

    Itsumi, J. [Kumamoto Institute of Technology, Kumamoto (Japan)

    1997-11-25

    Various measurements are conducted in an energy-efficient house equipped with a photovoltaic power generation system and actually lived in by people, and matching between the household load and photovoltaic power generation, and the consumption of power, are examined. As the result investigation of power consumption in the house, it is found that 13.31kWh is consumed in the daytime in winter, and 14.15kWh in summer. Thirty-two 153W modules are used, and they produce 12.74kWh in four hours on a fine summer day, which amount nearly satisfies the demand of the household. As for the records during a year beginning in May, 1996, it is found that an annual amount of 4326kWh was generated, with 68% being surplus and 32% consumed for the household. Details of the household consumption were that 49.2% was consumed for house heating and cooling and 34.1% for cooking, the two in total occupying more than 80% of the whole household consumption. Energy-saving behavior is evaluated by comparing the energy-efficient house with some ordinary residential houses in Kumamoto City, and it is found that there is a yearly difference of 104,310 yen in electricity bill or 47% in energy saving effect. 5 refs., 4 figs., 4 tabs.

  1. Thermal design of a modern, two floor, zero energy house in a desert compound

    KAUST Repository

    Serag-Eldin, M. A.

    2010-12-01

    The paper presents a thermal analysis and design of a fully equipped, air-conditioned, zero energy house located in a desert compound at 24.5° latitude. Unlike previous designs the home is two floors high, which makes the balancing of energy supply and demand even more challenging. The roof of the house carries an array of retractable Photovoltaic modules and cover. During day light hours the modules convert the incident sun energy into useful electrical power, while shielding the roof from direct sun-radiation. At night time, the roof cover and modules are retracted to expose the roof to the cool night-sky, thus enhancing cooling. The paper employs time-dependent modeling of Solar input and heat transfer to predict the roof, wall and window temperature distributions and cooling loads, as well as energy generated by the modules. With the aid of battery storage, the modules provide the entire energy needs of the house. The paper displays the results of energy balances for three key days of the year which demonstrate that the proposed two floor design is indeed capable of operating without external energy. © 2010 IEEE.

  2. Analysis of Cool Roof Coatings for Residential Demand Side Management in Tropical Australia

    Directory of Open Access Journals (Sweden)

    Wendy Miller

    2015-06-01

    Full Text Available Cool roof coatings have a beneficial impact on reducing the heat load of a range of building types, resulting in reduced cooling energy loads. This study seeks to understand the extent to which cool roof coatings could be used as a residential demand side management (DSM strategy for retrofitting existing housing in a constrained network area in tropical Australia where peak electrical demand is heavily influenced by residential cooling loads. In particular this study seeks to determine whether simulation software used for building regulation purposes can provide networks with the ‘impact certainty’ required by their DSM principles. The building simulation method is supported by a field experiment. Both numerical and experimental data confirm reductions in total consumption (kWh and energy demand (kW. The nature of the regulated simulation software, combined with the diverse nature of residential buildings and their patterns of occupancy, however, mean that simulated results cannot be extrapolated to quantify benefits to a broader distribution network. The study suggests that building data gained from regulatory simulations could be a useful guide for potential impacts of widespread application of cool roof coatings in this region. The practical realization of these positive impacts, however, would require changes to the current business model for the evaluation of DSM strategies. The study provides seven key recommendations that encourage distribution networks to think beyond their infrastructure boundaries, recognising that the broader energy system also includes buildings, appliances and people.

  3. Use of waste heat from a dairy for heating of a community house

    Energy Technology Data Exchange (ETDEWEB)

    Rehn, C

    1976-01-01

    In a dairy, a lot of cooling capacity is needed. This article describes how this waste heat can be used for heating a community house including a sport establishment and producing hot water for that house. Four different technical solutions are discussed; (1) floor heat, (2) heat transfer connected to the ventilation, (3) regenerative heat exchanger, and (4) use of heat pumps.

  4. Improvement of performance of the HARBEMAN house; Habiman hausu no seino kaizen ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T. [Tohoku Univ., Sendai (Japan). Dept. of Aeronautics and Space Eng.; Fujino, T. [Mitsubishi Heavy Industires Ltd., Tokyo (Japan)

    1998-12-05

    A natural energy autonomous house (HARBEMAN house) was built in 1996 in Sendai. This house combinedly utilizes solar thermal, photovoltaic, sky radiation cooling, rainwater energies and so on. In order to utilize a lot kind of natural energies more efficiently, we will improve thermal performance of the solar collector, the sky radiator, and so on. The effect of thermal insulation, tank size, and window glazing on thermal performance will also be examined. This article reports on the improved performance of the HARBEMAN house. (author)

  5. Computer Simulation Performed for Columbia Project Cooling System

    Science.gov (United States)

    Ahmad, Jasim

    2005-01-01

    This demo shows a high-fidelity simulation of the air flow in the main computer room housing the Columbia (10,024 intel titanium processors) system. The simulation asseses the performance of the cooling system and identified deficiencies, and recommended modifications to eliminate them. It used two in house software packages on NAS supercomputers: Chimera Grid tools to generate a geometric model of the computer room, OVERFLOW-2 code for fluid and thermal simulation. This state-of-the-art technology can be easily extended to provide a general capability for air flow analyses on any modern computer room. Columbia_CFD_black.tiff

  6. Development of an innovative heat supply concept for a new housing area

    OpenAIRE

    Schmidt, Dietrich; Schurig, Marlen; Kallert, Anna; Orozaliev, Janybek; Best, Isabelle; Vajen, Klaus; Reul, Oliver; Bennewitz, Jochen; Gerhold, Petra

    2016-01-01

    The energy demand of buildings for heating and cooling is responsible for more than one third of the world's final energy consumption. Therefore the identification of innovative heat supply concepts based on renewable energies is required. The utilization of renewable energies in combination with efficient supply technologies increases the "sustainability" of new housing areas. For the new housing area "Zum Feldlager", located in Kassel (Germany), various supply concepts are investigated. Mai...

  7. Investigation of Indonesian Traditional Houses through CFD Simulation

    Science.gov (United States)

    Suhendri; Koerniawan, M. D.

    2017-03-01

    Modern buildings in Indonesia rely mostly on artificial lighting, heating, cooling and ventilation. It means more energy is used to drive mechanical appliances, and presumably not sustainable. Meanwhile modern buildings consume much energy, traditional architectures are known as the source of knowledge for sustainable, energy efficient and climate responsive design. Noticeably, one of the differences between modern and traditional buildings in Indonesia is shown in their strategy to provide thermal comfort to the user. Traditional buildings use natural ventilation, but modern buildings use mechanical air conditioning. By focusing on wind-driven ventilation, the study aims to investigate natural ventilation strategy of Indonesian traditional house, and their potential improvement to be used in modern Indonesian buildings. Three traditional houses are studied in this research, representing west, central, and east Indonesia. The houses are Lampung traditional house, Javanese traditional house, and Toraja traditional house. CFD simulation is conducted to simulate wind-driven ventilation behaviour and the temperature of the buildings. Concisely, the wind-natural ventilation of case study houses is potential to provide thermal comfort inside the houses. However, the strategy still can be optimized by adding some other passive design strategies: sun-shading; vegetation; or buildings arrangement in the traditional dwelling. Consideration about the roof’s shape and windows position to the roof is important as well to create a uniform air distribution.

  8. Environment-oriented private house of Mr.K in Kyushu. Self-sufficing concept of the entire house demands for heating and cooling by natural energy, including the sewage disposal; Kyushu ni tatsu kankyo kyoseigata jutaku (K tei). Danbo/ryobo/seikatsu haisui no subete wo teinai deno shizen energy wo mochiite jusoku/shorisuru konseputo

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, O. [Kumamoto Univ. (Japan). Faculty of Engineering

    1996-09-30

    A case study for a natural energy system serving for a private house is reported with the outline of the system and the measurement results of the temperature and heat environments both in summer and winter. A 2-story house with an area of 141m{sup 2} and a total floor area of 186m{sup 2} is introduced including the site where it stands. Then, it is described on a floor heating system by circulating warm water through pipings embedded in the structural bodies, made of reinforced concrete from a solar heat collector consisted of 20 galvanized steel pipes of 100mm in diameter and 7m in length, a wall and ceiling cooling system with well water that gushes out at a rate of about 2 tons/min, and also the use of 20 amorphous solar cell panels as the source of electric power generation of about 17W capacity for these 2 systems, a house sewage disposal after the first stage treatment into the soil of kicken garden and so forth. Upon these system installed, 50 measurement items such as temperatures of outdoor and each room, humidity, quantity of sunshine and so on were measured for 1 year, and the instrumentation data were collected. From various analytical results, it was revealed that the highest temperature of warm water pipings in winter was 32{degree}C, while the lowest temperature of 17{degree}C was recorded in the morning and the surface temperature in the structural bodies of a room located at the south-east corner remained stable in summer more or less at 27{degree}C and so forth. 13 figs., 1 tab.

  9. Mass Balance Applied to Brazilian Conventional Broiler Houses during One Production Cycle

    Directory of Open Access Journals (Sweden)

    A Migliavacca

    Full Text Available ABSTRACT Brazil plays an important role in global poultry production as it is the world's largest chicken exporter and the third largest broiler producer. Despite the development achieved by the Brazilian broiler industry as a result of the integrated production system, many obstacles still need to be overcome, in particular, housing environment. In this regard, detailed knowledge of the inputs, outputs, and primary waste generated by broiler production cycles is essential to establish a baseline for energy balance research studies and to develop environmental solutions. This article proposes a mass balance of conventional broiler houses of southern Brazil sheds in order to predict their outputs, but that may also be applicable to other regions with similar climate. Control volumes considered the heating, cooling, and rearing processes. All generated products and wastes were estimated considering litter production and the total production per cycle. Despite the variety of the microclimates, the results were very close to those reported in experiments, indicating that this model is adequate for this kind of estimation.

  10. Analysis of Turbine Blade Relative Cooling Flow Factor Used in the Subroutine Coolit Based on Film Cooling Correlations

    Science.gov (United States)

    Schneider, Steven J.

    2015-01-01

    Heat transfer correlations of data on flat plates are used to explore the parameters in the Coolit program used for calculating the quantity of cooling air for controlling turbine blade temperature. Correlations for both convection and film cooling are explored for their relevance to predicting blade temperature as a function of a total cooling flow which is split between external film and internal convection flows. Similar trends to those in Coolit are predicted as a function of the percent of the total cooling flow that is in the film. The exceptions are that no film or 100 percent convection is predicted to not be able to control blade temperature, while leaving less than 25 percent of the cooling flow in the convection path results in nearing a limit on convection cooling as predicted by a thermal effectiveness parameter not presently used in Coolit.

  11. Introduction of a Greenhouse as an Alternative Housing System to a Conventional House and Its Impact on Broiler Performance and Blood and Carcass Variables

    Directory of Open Access Journals (Sweden)

    Khajali F

    2013-01-01

    Full Text Available A study was conducted to compare the growth performance as well as blood and carcass variables of two broiler strains reared in a conventional broiler house and a modified greenhouse equipped with cooling pads and tunnel ventilation system. Eight hundred day-old chickens of two commercial strains (Ross  308 and Lohmann were selected and placed in  8 floor pens (4 pens of  50 broilers for each strain in each housing system. The pens were located randomly throughout the modified greenhouse or the conventional broiler house (two-way ANOVA design. The broilers were provided a standard starter and grower diets  ad libitum. The environmental conditions (i.e.  temperature, relative humidity, lighting program and ventilation rate were kept  similar between the two houses. The results showed that the birds in the greenhouse consumed significantly (P

  12. IDEAhaus: A Modular Approach to Climate Resilient UK Housing

    Directory of Open Access Journals (Sweden)

    Greg Keeffe

    2014-09-01

    Full Text Available This paper describes the result of a project to develop climate adaptation design strategies funded by the UK’s Technology Strategy Board. The aim of the project was to look at the threats and opportunities presented by industrialized and house-building techniques in the light of predicted future increases in flooding and overheating due to anthropogenic climate change. The paper shows that the thermal performance of houses built to the current UK Building Regulations is not adequate to cope with changing weather patterns, and in light of this, develops a detailed design for a new house: one that is industrially produced and climatically resilient, but affordable. This detailed concept IDEAhaus of a modular house is not only flood-proof to a water depth of 750 mm, but also is designed to utilize passive cooling, which dramatically reduces the amount of overheating, both now and in the future.

  13. A Proposal for Desert House Design in Egypt Using Passive Ground Cooling Techniques

    Directory of Open Access Journals (Sweden)

    Mohamed Medhat Dorra

    2018-06-01

    Full Text Available An area less than 5.5% of Egyptian territory is where most of Egypt‘s population lives in. A narrow strip of land forms the Nile Valley and Delta sector.The National Project for Desert Hinterlands is one of the urban projects targeting rehabilitation of the poor in alternative villages in the near desert to stop urban sprawl over agricultural land and decrease the congestion in the old habitats. Low cost energy efficient houses are the aim of the architect in similar projects taking in consideration the high electricity consumption of Egypt’s residential sector. Based on a literature review, this paper presents a proposal for designing desert dwellings   that accommodates the hot dry climate by incorporating passive elements and using stabilized earth blocks as a local building material. Furthermore, simulation is used to test alternative proposals. The results show that an underground constructed house with a sunken courtyard incorporating an Earth to Air Heat Exchanger System (EAHE can reduce between 42-72% of energy consumption used to achieve thermal comfort compared to contemporary desert housing projects.

  14. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    Science.gov (United States)

    Shrestha, Suman K.

    referenced to the rotor surface speed for radial injection cooling. The mass flow rates for the radial injection were 0.032, 0.0432, 0.054 and 0.068 Kg/min, which result in average injection speed of 150, 200, 250 and 300% of rotor surface speed. Several thermocouples were attached at various circumferential directions of the bearing sleeve, two plenums, bearing holder and ball bearing housings to collect the temperature data of the bearing at 30krpm under 10lb of load. Both axial cooling and radial injection are effective cooling mechanism and effectiveness of both cooling methods is directly proportional to the total mass flow rates. However, axial cooling is slightly more efficient in controlling the average temperature of the bearing sleeve, but results in higher thermal gradient of the shaft along the axial direction and also higher thermal gradient of the bearing sleeve along the circumferential direction compared to the radial injection cooling. The smaller thermal gradient of the radial injection cooling is due to the direct cooling effect of the shaft by impinging jets. While the axial cooling has an effect on only the bearing, the radial injection has a cooling effect on both the bearing sleeve and shaft. It is considered the radial injection cooling needs to be further optimized in terms of number of injection holes and their locations.

  15. Technology Roadmaps: Solar Heating and Cooling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-09-06

    The solar heating and cooling (SHC) roadmap outlines a pathway for solar energy to supply almost one sixth (18 EJ) of the world's total energy use for both heating and cooling by 2050. This would save some 800 megatonnes of carbon dioxide (CO2) emissions per year; more than the total CO2 emissions in Germany in 2009. While solar heating and cooling today makes a modest contribution to world energy demand, the roadmap envisages that if concerted action is taken by governments and industry, solar energy could annually produce more than 16% of total final energy use for low temperature heat and nearly 17% for cooling. Given that global energy demand for heat represents almost half of the world's final energy use -- more than the combined global demand for electricity and transport -- solar heat can make a significant contribution in both tackling climate change and strengthening energy security.

  16. Technology Roadmaps: Solar Heating and Cooling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    The solar heating and cooling (SHC) roadmap outlines a pathway for solar energy to supply almost one sixth (18 EJ) of the world’s total energy use for both heating and cooling by 2050. This would save some 800 megatonnes of carbon dioxide (CO2) emissions per year; more than the total CO2 emissions in Germany in 2009. While solar heating and cooling today makes a modest contribution to world energy demand, the roadmap envisages that if concerted action is taken by governments and industry, solar energy could annually produce more than 16% of total final energy use for low temperature heat and nearly 17% for cooling. Given that global energy demand for heat represents almost half of the world’s final energy use – more than the combined global demand for electricity and transport – solar heat can make a significant contribution in both tackling climate change and strengthening energy security.

  17. Bioclimatic building in Hungary: results of the Pecs house

    Energy Technology Data Exchange (ETDEWEB)

    Fueloep, L.; Szasz, J. (Pollack Mihaly Coll. of Technology, Pecs (HU))

    1990-09-01

    The house was designed on a split-level to fit into a slope, with close attention paid to the reduction of heat losses, the increasing of passive gains and the maintenance of bioclimatic comfort. The building's rounded contours reduce turbulence and edge effects. A totally glazed south side incorporates two thermosyphon mass walls as well as a two-storey high sunspace. This unheated intermediate space acts as a buffer between indoors and outdoors and maximises solar gain, which can however be controlled by internal shading. A fan assisted central gravel packed tower and a rock bed floor provide heat storage. There are two 18 m{sup 2} areas of thermosyphon walls, where glass on polycarbonate is used to cover 0.45 m of dark stone mass. In 1989 the glazed wall was retrofitted to incorporate honeycomb transparent insulation, which still allows radiation gain but minimizes heat loss. Transparent insulation is also used in a skylight which is important for lighting the hallway but which would otherwise contribute to heat loss. Natural and forced ventilation as well as a cool air-pond contributes to cooling. Auxiliary floor heating is supplied by gas. In one room underfloor PCM batteries charged by discount night electricity are used for heating. A fireplace is also provided. (author).

  18. Performance analysis of solar air cooled double effect LiBr/H2O absorption cooling system in subtropical city

    International Nuclear Information System (INIS)

    Li, Zeyu; Ye, Xiangyang; Liu, Jinping

    2014-01-01

    Highlights: • The meteorological data during the working period of air conditioning was measured. • The suitable working range of collector temperature of system was gotten. • The characteristic of hourly and monthly total efficiency of system were obtained. • The yearly performance of system was calculated. - Abstract: Due to the absence of cooling tower and independent on water, the air cooled solar double effect LiBr/H 2 O absorption cooling system is more convenient to be used in commercial building and household use. The performance with collector temperature is an important field for such system. The paper mainly deals with the performance with collector temperature for the solar air cooled double effect LiBr/H 2 O absorption cooling system in subtropical city. The parameters of system are: aperture area of collector array is 27 m 2 , tilted angle of collector with respect to the horizontal plane is 20 toward to south evaporator temperature is 5 °C and the cooling capacity is 20 kW. The simulation is based on the meteorological data of monthly typical day which was summarized from a year round measured data. A corresponding parametric model was developed. The hourly and average performance with the collector temperature for monthly typical day was obtained and discussed. It was found that the suitable working range of inlet temperature of collector is 110–130 °C to improve performance and lower the risk of crystallization. The difference of hourly total efficiency in 9:00–16:00 is less, and the monthly total efficiency from May to October is approximate. The yearly performance of system including total efficiency, cooling capacity per area of collector and solar fraction was given. Furthermore, the effect of effectiveness of heat exchanger and pressure drop on total efficiency and solar fraction was studied and compared. The paper can serve as a preliminary investigation of solar air cooled double effect LiBr/H 2 O absorption cooling system in

  19. House of Generations

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2017-01-01

    only the benefits of living close to the family. The Aarhus Municipality project "House of Generations" is a vision for creating a framework for relationships across all generations, for meaningful encounters and for rewarding neighbourliness. Three of Aarhus Municipality's magistrate departments...... participate in the project: Health and Care, Children and Youth, and Social Conditions and Employment. A public housing association that provides student dorms also participates in the project. The physical framework will be a building with a total area of approx. 25,000 m², located at Pier 4, at Aarhus......' harbour areas. The building will be a multi-generational house comprising a mixture of flexible public housing units for students, the elderly and residents who require care (elderly disabled people and people with acquired brain injuries). The building will be connected with common areas located in close...

  20. Automated roof window control system to address overheating on renovated houses

    DEFF Research Database (Denmark)

    Psomas, Theofanis Ch.; Heiselberg, Per Kvols; Lyme, Thøger

    2017-01-01

    Highlights •Manually controlled passive cooling system do not assure high quality environment. •Automated window system reduces overheating risk in houses of temperate climates. •Window system offers similar indoor air quality with mechanical ventilation system. •User behavior on window system...

  1. Experimental study on solar desiccant cooling system. 2nd Report; Taiyonetsu kudo desiccant cooling system no jikkenteki kento. 2

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, H; Funato, H [Fukuoka Institute of Technology, Fukuoka (Japan); Kuma, T [Seibu Giken Co. Ltd., Fukuoka (Japan)

    1996-10-27

    Study has been made about a desiccant cleaning system using solar heated water for regenerating the dehumidifier. A dehumidifier and evaporation coolers are combined to attain a synergistic effect in dehumidifying and cooling the air in the house. The simultaneous control of humidity and temperature, however, is quite difficult. Under the circumstances, an evaporation cooler was removed from the outdoor air intake side, to leave a humidifier alone for the control of humidity only. In addition, the length of the dehumidifier was reduced into half for saving fan driving power and for downscaling the model. With only one evaporation cooler in operation that is installed at the exhaust side, the cooling effect is diminished by half. For dealing with the situation, ultrasonic atomization is performed at the exhaust side evaporation cooler for the improvement of the air cooling effect for the next sensible heat exchanger (intake side). The return air is heated by the solar heater water (approximately 60{degree}C hot), regenerates the dehumidifier, and then exhausted. The atomization process elevates the cooling effect, and the resultant cooling effect was as high as that expected from a 2-cooler setup. The dehumidification effect, however, lowers a little. Exclusion of the atomization process will enhance the dehumidification effect, but will reduce the cooling effect as well. 3 refs., 8 figs., 3 tabs.

  2. Numerical analysis for temperature profile of the closed house using computational fluid dynamics

    Science.gov (United States)

    Setiadi, Rizki; Munadi, Tauviqirrahman, Mohammad

    2018-03-01

    This study aims to analyze the air temperature distribution in the closed house system for broiler using ABAQUS CFD Model. The obtained data is used for placing the temperature sensor before making the control system for the closed house. The dimesion of the experimental house was 30 m × 12 m × 2 m (length × width × height) which could be occupied by 7.500 broiler. The wall was made from expose mercy brick and curtain, ventilation system used 7 exhaust fan with diameter 1 m and 2 cooling unit, the roof was made from wood, and system used 45 of 7 watt lamp. The results of the analysis show that temperature distribution occurs on temperature 21-33.5°C and still relatively comfortable for broiler at the age of 1-21days. The air temperature distribution near the cooling unit is lower and increases to near the exhaust fan. In addition, the air temperature in the area near the roof is more high than others.

  3. Mini-Membrane Evaporator for Contingency Spacesuit Cooling

    Science.gov (United States)

    Makinen, Janice V.; Bue, Grant C.; Campbell, Colin; Petty, Brian; Craft, Jesse; Lynch, William; Wilkes, Robert; Vogel, Matthew

    2015-01-01

    The next-generation Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is integrating a number of new technologies to improve reliability and functionality. One of these improvements is the development of the Auxiliary Cooling Loop (ACL) for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feedwater assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the full-sized AEMU PLSS cooling device, the Spacesuit Water Membrane Evaporator (SWME), but Mini-ME occupies only approximately 25% of the volume of SWME, thereby providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology, which relies upon a Secondary Oxygen Vessel; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a reduction in SOV size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The first iteration of Mini-ME was developed and tested in-house. Mini-ME is currently packaged in AEMU PLSS 2.0, where it is being tested in environments and situations that are representative of potential future Extravehicular Activities (EVA's). The second iteration of Mini-ME, known as Mini-ME2, is currently being developed to offer more heat rejection capability. The development of this contingency evaporative cooling system will contribute to a more robust and comprehensive AEMU PLSS.

  4. Development of cooling and cleaning systems for enhanced gas ...

    African Journals Online (AJOL)

    In order to address these tar related problems a cleaning and cooling system has been developed in house that facilitates tar removal to acceptable levels tolerated by the internal combustion (IC) engine and meets emission standards as well. The main objective of the present work is to reduce tar level and develop control ...

  5. Optimal Integration of Cascade Thermoelectric Cooler into Electronic Housing: Experimental Approach

    Science.gov (United States)

    Semeniuk, V.; Protsenko, D.

    2018-06-01

    The problem of the optimal integration of thermoelectrically cooled optoelectronic components into an electronic housing is studied with the emphasis on practical implementation. The lines of 2-stage and 3-stage thermoelectric coolers (TECs) compatible with TO8 housing have been developed, and their parameters are measured in a wide range of heat sink temperatures. The TECs are optimized to receive a temperature difference of 100-110 K under a heat load from 70 mW to 100 mW with minimal power consumption. To fit into a standard housing interior, all the TECs have the same overall dimensions, regardless of the number of stages. Details of the TEC configurations and their performance characteristics are presented and discussed.

  6. Total Energy. Sustainable cooling and heating in supermarkets; Total Energy. Duurzame koeling en verwarming supermarkten

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-03-15

    In 8 articles attention is paid to different aspects of cooling and heating in supermarkets: new coolants in the food retail sector, the climate plan of the Dutch Food Retail Association (CBL), he Round Table discussion with between CBL and supermarket chains about research results, approach and targets, the use of CO2 refrigeration in supermarkets, leakage of coolants from refrigerators and freezers in Dutch supermarkets, the energy efficient and environment-friendly refrigerator and freezer equipment of the distribution centre of supermarket chain C1000 in Raalte, Netherlands, changes for cooling techniques in the EIA energy list (Energy investment deduction scheme) and finally education options for the refrigeration industry in the Netherlands. [Dutch] In 8 artikelen wordt aandacht geschonken aan verschillende aspecten m.b.t. koeling en verwarming in supermarkten: nieuwe koelmiddelen in de 'food retail sector, het klimaatplan van de brancheorganisatie Centraal Bureau Levensmiddelenhandel (CBL), het Rondetafel overleg met de CBL en supermarktketens over onderzoeksresultaten, aanpak en doelen, de toepassing van CO2 koeling in supermarkten, lekkage van koelmiddelen uit koel- en vriesinstallaties in Nederlandse supermarkten, de energiezuinige en milieuvriendelijke koel-vriesinstallatie van het distributiecentrum van de supermarktketen C1000 in Raalte, wijzigingen voor koeltechniek in de EIA energielijst (Energie Investeringsaftrek subsidieregeling), en tenslotte opleidingsmogelijkheden voor de koeltechnische sector in Nederland.

  7. Actual proof study of energy autonomous house; Energy jiritsu house no jissho jikken. 1

    Energy Technology Data Exchange (ETDEWEB)

    Masuzawa, O; Masuzawa, C

    1997-11-25

    A discussion was given on an `energy autonomous house` which utilizes more effectively photovoltaic power generation, solar heat and light in designing a wooden house to be built by using the conventional construction method. According to the plan, photovoltaic power generation modules and heat collectors are installed superimposed on a roof facing south. Heat-collected air is sent below the floor and the heat is stored in the concrete in winter, utilized as the floor heating type room heater. The hot air is used for hot water supply in other seasons. The building is of two stories with a total area of 118 m {sup 2}, and the photovoltaic generation capacity is 3.48 kW. The photovoltaic generation amount was calculated from insolation forecasted by the AMEDAS system, and energy balance of this house was estimated. The result therefrom may be summarized as follows: total energy supplied reached 11.6 Gcal, signifying that about 10.8% of the energy irradiated onto the building is utilized; ratio of the photovoltaic and solar heat utilization is 27% versus 73%; and energy consumption in this house was estimated and calculated from actual results, airtightness and adiabatic performance of old houses, whereas the energy autonomous rate has reached 92.8%. 5 refs., 2 figs., 8 tabs.

  8. Exergy analysis of a combined power and cooling cycle

    International Nuclear Information System (INIS)

    Fontalvo, Armando; Pinzon, Horacio; Duarte, Jorge; Bula, Antonio; Quiroga, Arturo Gonzalez; Padilla, Ricardo Vasquez

    2013-01-01

    This paper presents a comprehensive exergy analysis of a combined power and cooling cycle which combines a Rankine and absorption refrigeration cycle by using ammonia–water mixture as working fluid. A thermodynamic model was developed in Matlab ® to find out the effect of pressure ratio, ammonia mass fraction at the absorber and turbine efficiency on the total exergy destruction of the cycle. The contribution of each cycle component on the total exergy destruction was also determined. The results showed that total exergy destruction decreases when pressure ratio increases, and reaches a maximum at x ≈ 0.5, when ammonia mass fraction is varied at absorber. Also, it was found that the absorber, the boiler and the turbine had the major contribution to the total exergy destruction of the cycle, and the increase of the turbine efficiency reduces the total exergy destruction. The effect of rectification cooling source (external and internal) on the cycle output was investigated, and the results showed that internal rectification cooling reduces the total exergy destruction of the cycle. Finally, the effect of the presence or absence of the superheater after the rectification process was determined and it was obtained that the superheated condition reduces the exergy destruction of the cycle at high turbine efficiency values. Highlights: • A parametric exergy analysis of a combined power and cooling cycle is performed. • Two scenarios for rectifier cooling (internal and external) were studied. • Internal cooling source is more exergetic efficient than external cooling source. • The absorber and boiler have the largest total exergy destruction. • Our results show that the superheater reduces the exergy destruction of the cycle

  9. The impact of weather variation on energy consumption in residential houses

    International Nuclear Information System (INIS)

    Fikru, Mahelet G.; Gautier, Luis

    2015-01-01

    Highlights: • There is evidence for significant intraday variation of energy use. • The sensitivity of energy use to weather variation falls via efficiency features. • The sensitivity of energy use to weather depends on the specific time of day/night. • High frequency data helps to accurately model the energy use-weather relationship. - Abstract: This paper studies the impact of weather variation on energy use by using 5-minutes interval weather–energy data obtained from two residential houses: house 1 is a conventional house with advanced efficiency features and house 2 is a net-zero solar house with relatively more advanced efficiency features. Our result suggests that energy consumption in house 2 is not as sensitive to changes in weather variables as the conventional house. On average, we find that a one unit increase in heating and cooling degree minutes increases energy use by about 9% and 5% respectively for house 1 and 5% and 4% respectively for house 2. In addition, our findings suggest that non-temperature variables such as solar radiation and humidity affect energy use where the sensitivity rates for house 2 are consistently lower than that of house 1. Furthermore our result suggests that the sensitivity of energy use to weather depends on the season and specific time of the day/night

  10. Some Environmental and Economic Aspects of Energy Saving Measures in Houses. An estimation model for total energy consumption and emissions to air from the Norwegian dwelling stock, and a life cycle assessment method for energy saving measures in houses

    Energy Technology Data Exchange (ETDEWEB)

    Myhre, L

    1995-12-01

    Motivated by the need to reduce the total energy consumption and the environmental load from society, this doctoral thesis discusses energy conservation measures on existing houses. Alternative additional thermal insulation measures are assessed using an interdisciplinary life cycle approach. The first task is to develop an interdisciplinary assessment method for building improvement measures, taking account of energy consumption, resource consumption, emissions to air of environmentally harmful gases, and economic costs during the entire life cycle of the building. The second task is to develop an estimation model for the total energy consumption and emissions to air of environmentally harmful gases from the dwelling stock of Norway. Finally, the third task is to assess the total energy saving potential and the total environmental benefits of energy saving measures in houses on a national level, including only life cycle analyses of additional thermal insulation measures on single houses. Chap 2 describes the dwelling stock in Norway. Chaps 3 and 4 present an estimation model for total energy consumption and emissions to air from the dwelling stock, and calculations using the model. Chaps 5 and 6 propose and use a calculation method for the assessment of additional thermal insulation measures, using a ``cradle-to-grave`` approach. Since hydroelectric power is the main energy source in this sector in Norway, estimated payback periods for emissions to air are long. But hydroelectric power saved in this sector may be used to obtain reduction in fossil fuel use in other sectors as discussed in Chap 7. Some of the topics discussed are further elaborated on in appendices. 107 refs., 39 figs, 88 tabs.

  11. Performance of passive solar and energy conserving houses in California

    Science.gov (United States)

    Mahajan, S.; Newcomb, C.; Shea, M.; Mort, D.

    1983-11-01

    This report provides a technical description of the methodology and the results of a two year effort to collect field data on the performance of passive solar and energy conserving houses in California. Sixty-three passive solar houses were visited and several hours were spent with the homeowner obtaining building details, management procedures, architectural plans, photographs, and at least a year of billing data. With this information thermal performance parameters were calculated for each of the houses. Eleven of the above sixty-three Class C sites (nine passive solar and two energy conserving houses) were instrumented and monitored using the SERI Class B methodology as a guideline. Continuous data were collected for one year using up to 18 different sensors to measure temperatures, electric power, insolation, and the status of fans, gas burners, and moveable insulation. In addition careful one time measurements were made to determine the loss coefficient, infiltration rate, and furnace efficiency. Analysis of this data giving comfort conditions maintained and energy uses for a complete heating and cooling season for each of the houses is presented.

  12. Indoor Thermal Environment of Temporary Mobile Energy Shelter Houses (MeSHs in South Korea

    Directory of Open Access Journals (Sweden)

    Jeong-Gook Kim

    2015-10-01

    Full Text Available Temporary housing must be developed to support the long-term residence needs of disaster victims. The present study assesses a temporary housing unit, the so-called Mobile Energy Shelter House (MeSH, incorporating the “Korean Dwelling Insulation Standard” in order to reduce energy usage for cooling and heating. To assess energy performance, the characteristics of the indoor thermal environment were measured during the winter and summer seasons. In summer, at maximum insolation, the outdoor temperature was 37.6 °C and the indoor temperature of the MeSH ranged from 18 to 24 °C when the cooling system was not used. Conversely, during winter, the average outdoor temperature was −11.3 °C and the indoor temperature ranged from 16.09 to 20.63 °C when a temperature-controlled floor-heating was installed. Furthermore, the Predicted Mean Vote (PMV was adopted to determine whether the ISO 7730 comfort criterion (i.e., PMV range from −0.5 to +0.5 was achieved. Based on the calculations presented here, PMV in summer ranged from −1.21 to +1.07 and that in winter ranged from −0.08 to −0.85, suggesting that the thermal environment is not always comfortable for occupants in either summer or winter. Nevertheless, the ISO comfort criterion can be achieved through varying air velocity in summer and changing clothing characteristics in winter. A comparison between yearly energy demand of existing characteristic temporary housing (Shelter House and the MeSH modules used in this study was performed. The simulation results show a 60% difference in energy demand between MeSH and existing temporary housing shelter houses.

  13. Design, construction, and testing of a residential solar heating and cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Ward, D.S.; Loef, G.O.G.

    1976-06-01

    The NSF/CSU Solar House I solar heating and cooling system became operational on 1 July 1974. During the first months of operation the emphasis was placed on adjustment, ''tuning,'' and fault correction in the solar collection and the solar/fuel/cooling subsystems. Following this initial check out period, analysis and testing of the system utilizing a full year of data were accomplished. This report discusses the results of this analysis of the full year of operation. (WDM)

  14. Classification of Inheritance Shop Houses in George Town, Penang - UNESCO World Heritage Site

    Directory of Open Access Journals (Sweden)

    Rozliani Mansor

    2012-09-01

    Full Text Available Shop house is an urban terrace house attribute of Asian towns from the 18 th century which usually integrates a shop or business premise on the ground floor whilst the family dwells on the upper level, providing both ease and safety. The shop house might also be used entirely as dwelling quarters. Shop houses are constructed in rows and each row is arranged in blocks enclosed within a grid of main roads, back lanes and side roads. A shop house is usually two or three storeys high and is long and narrow, sharing a party wall with neighbours on either side. The Penang shop house is a ideal paradigm of a green building, using materials that are locally obtainable such as lime, clay stone and timber and suited to local geology and weather conditions. Shop houses also possessing architectural characteristics such as air vents and air-well that assist with natural ventilation and cooling. This paper will discuss categories and styles of the shop houses in historic city of George Town which can be divided into nine major groups.

  15. Summary of detailed energy audit and building simulation on archetype sustainable house, Woodbridge ON

    Energy Technology Data Exchange (ETDEWEB)

    Fung, A. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering; Dembo, A.; Zhou, J. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Architectural Science

    2009-07-01

    This paper described energy and audit and building simulations conducted on an archetype sustainable house located in Woodbridge, Ontario. The house formed part of a project to construct low energy, sustainable house designs for mass production. The 2 houses formed a duplex. House A was designed using current best design practices, while house B was equipped with advanced and innovative technologies not commonly used in residential constructions. Natural Resources Canada's (NRCan) HOT2000 residential building simulation program was used to evaluate the performance of both houses in the duplex. The simulation program demonstrated that house B performed more efficiently than house A. However, neither houses met their designed values. Significantly larger space heating and cooling loads were identified. The program showed that additional weather-stripping around doors, and caulking around windows will help to reduce the amount of draft in the houses. Assessments are also needed to measure heat losses from the common wall in the basement. It was concluded that the energy performance of the house can be optimized by using the appropriate sealing techniques throughout the building envelope. 2 refs., 1 tab.

  16. Small mammal use of native warm-season and non-native cool-season grass forage fields

    Science.gov (United States)

    Ryan L Klimstra,; Christopher E Moorman,; Converse, Sarah J.; Royle, J. Andrew; Craig A Harper,

    2015-01-01

    Recent emphasis has been put on establishing native warm-season grasses for forage production because it is thought native warm-season grasses provide higher quality wildlife habitat than do non-native cool-season grasses. However, it is not clear whether native warm-season grass fields provide better resources for small mammals than currently are available in non-native cool-season grass forage production fields. We developed a hierarchical spatially explicit capture-recapture model to compare abundance of hispid cotton rats (Sigmodon hispidus), white-footed mice (Peromyscus leucopus), and house mice (Mus musculus) among 4 hayed non-native cool-season grass fields, 4 hayed native warm-season grass fields, and 4 native warm-season grass-forb ("wildlife") fields managed for wildlife during 2 summer trapping periods in 2009 and 2010 of the western piedmont of North Carolina, USA. Cotton rat abundance estimates were greater in wildlife fields than in native warm-season grass and non-native cool-season grass fields and greater in native warm-season grass fields than in non-native cool-season grass fields. Abundances of white-footed mouse and house mouse populations were lower in wildlife fields than in native warm-season grass and non-native cool-season grass fields, but the abundances were not different between the native warm-season grass and non-native cool-season grass fields. Lack of cover following haying in non-native cool-season grass and native warm-season grass fields likely was the key factor limiting small mammal abundance, especially cotton rats, in forage fields. Retention of vegetation structure in managed forage production systems, either by alternately resting cool-season and warm-season grass forage fields or by leaving unharvested field borders, should provide refugia for small mammals during haying events.

  17. Effects of housing system on the costs of commercial egg production.

    Science.gov (United States)

    Matthews, W A; Sumner, D A

    2015-03-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. © The Author 2015. Published by Oxford University Press on behalf of Poultry Science Association.

  18. Two neural network based strategies for the detection of a total instantaneous blockage of a sodium-cooled fast reactor

    International Nuclear Information System (INIS)

    Martinez-Martinez, Sinuhe; Messai, Nadhir; Jeannot, Jean-Philippe; Nuzillard, Danielle

    2015-01-01

    The total instantaneous blockage (TIB) of an assembly in the core of a sodium-cooled fast reactor (SFR) is investigated. Such incident could appear as an abnormal rise in temperature on the assemblies neighbouring the blockage. Its detection relies on a dataset of temperature measurements of the assemblies making up the core of the French Phenix Nuclear Reactor. The data are provided by the French Commission of Atomic and Alternatives Energies (CEA). Here, two strategies are proposed depending on whether the sensor measurement of the suspected assembly is reliable or not. The proposed methodology implements a time-lagged feed-forward neural (TLFFN) Network in order to predict the one-step-ahead temperature of a given assembly. The incident is declared if the difference between the predicted process and the actual one exceeds a threshold. In these simulated conditions, the method is efficient to detect small gradients as expected in reality. - Highlights: • We study the total instantaneous blockage (TIB) of a sodium-cooled fast reactor. • The TIB symptom is simulated as an abrupt rise on temperature (0.1–1 °C/s). • The goal is to improve the early detection of the incident. • Two strategies laying on neural networks are proposed. • TIB is detected in 3 s for 1 °C/s and 18–21 s for 0.1 °C/s

  19. Fiscal 1976 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for existing detached houses); 1976 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Kison kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-05-27

    This report describes the fiscal 1976 research result on solar cooling/heating and hot water supply systems for existing detached houses. In system analysis, various evaluation items of the primary experimental house to be constructed and the titled thermal system were determined, and its measurement/control online program was developed. In the R and D on equipment and materials, the performance of the vacuum collector prepared in last fiscal year was tested, and based on its result and study on optimum structure, the new prototype vacuum collector was fabricated. In the study on heat transfer and heat storage system equipment, the medium-scale latent heat type heat storage tank (1 x 10{sup 4}kcal in thermal capacity, 8 x 10{sup 3}kcal/h in thermal output) using ammonium alum was prepared. For a preventive mechanism against supercooling, reconsideration of structure of a crystal nucleus formation plate was necessary. In the study on refrigerator driven by Rankine cycle engine, the prototype compressor more than 3,000kcal/h in refrigeration capacity was fabricated. Construction of the experimental house and trial operation of the cooling/heating system were promoted. (NEDO)

  20. Neutron streaming analysis of an aqueous self-cooled blanket applied to MARS

    International Nuclear Information System (INIS)

    Varsamis, G.L.; Embrechts, M.J.; Steiner, D.

    1987-01-01

    A novel fusion reactor blanket concept, the Aqueous Self Cooled Blanket concept (ASCB), has recently been proposed. One of the first applications of this concept was to a MARS-like tandem mirror reactor. The design employs spiraling tubes of zircaloy-4 housed in a structural casing made of a vanadium alloy (V-15Cr-5Tl). One potential problem area for this design is the possibility for neutron streaming between the zircaloy tubes. This work examines this potential streaming path using the MCNP Monte Carlo code. The results of the total and the uncollided flux indicate a noticeable streaming effect on the uncollided flux only. An analysis of the energy deposition behind the blanket indicates that this effect is small, and therefore design modifications due to this streaming effect are not anticipated

  1. Performance characteristic of hybrid cooling system based on cooling pad and evaporator

    Science.gov (United States)

    Yoon, J. I.; Son, C. H.; Choi, K. H.; Kim, Y. B.; Sung, Y. H.; Roh, S. J.; Kim, Y. M.; Seol, S. H.

    2018-01-01

    In South Korea, most of domestic animals such as pigs and chickens might die due to thermal diseases if they are exposed to the high temperature consistently. In order to save them from the heat wave, numerous efforts have been carried out: installing a shade net, adjusting time of feeding, spraying mist and setting up a circulation fan. However, these methods have not shown significant improvements. Thus, this study proposes a hybrid cooling system combining evaporative cooler and air-conditioner in order to resolve the conventional problems caused by the high temperature in the livestock industry. The problem of cooling systems using evaporative cooling pads is that they are not effective for eliminating huge heat load due to their limited capacity. And, temperature of the supplied air cannot be low enough compared to conventional air-conditioning systems. On the other hand, conventional air-conditioning systems require relatively expensive installation cost, and high operating cost compared to evaporative cooling system. The hybrid cooling system makes up for the lack of cooling capacity of the evaporative cooler by employing the conventional air-conditioner. Additionally, temperature of supplied air can be lowered enough. In the hybrid cooling system, induced air by a fan is cooled by the evaporation of water in the cooling pad, and it is cooled again by an evaporator in the air-conditioner. Therefore, the more economical operation is possible due to additionally obtained cooling capacity from the cooling pads. Major results of experimental analysis of hybrid cooling system are as follows. The compressor power consumption of the hybrid cooling system is about 23% lower, and its COP is 17% higher than that of the conventional air-conditioners. Regarding the condition of changing ambient temperature, the total power consumption decreased by about 5% as the ambient temperature changed from 28.7°C to 31.7°C. Cooling capacity and COP also presented about 3% and 1

  2. Rotary engine cooling system

    Science.gov (United States)

    Jones, Charles (Inventor); Gigon, Richard M. (Inventor); Blum, Edward J. (Inventor)

    1985-01-01

    A rotary engine has a substantially trochoidal-shaped housing cavity in which a rotor planetates. A cooling system for the engine directs coolant along a single series path consisting of series connected groups of passages. Coolant enters near the intake port, passes downwardly and axially through the cooler regions of the engine, then passes upwardly and axially through the hotter regions. By first flowing through the coolest regions, coolant pressure is reduced, thus reducing the saturation temperature of the coolant and thereby enhancing the nucleate boiling heat transfer mechanism which predominates in the high heat flux region of the engine during high power level operation.

  3. Design and performance prediction of an adsorption heat pump with multi-cooling tubes

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.C.; Zhang, J.P. [College of Electromechanical Engineering, Qingdao University, Qingdao 266071 (China)

    2009-05-15

    Widespread application of adsorption heat pumps has been delayed not only by poor heat and mass transfer performance but also by low operating reliability because high vacuum must be maintained in the adsorption cooling system, especially in a water system. An adsorption cooling tube is a tube in which an adsorber, a condenser and an evaporator are all completely housed to construct a small scale adsorption cooling unit. In this work, an adsorption cooling tube and an adsorption heat pump with multi-cooling tubes are designed. A theoretical model is built to simulate the performance of the designed chiller. According to the results, the coefficient of performance and specific cooling power reach about 0.5 and 85 W/kg adsorbent, respectively, at the hot water temperature of 85 C. These results indicate that the designed heat pump in this work would provide a better choice if the operating reliability became crucial for an adsorption heat pump. (author)

  4. Design and performance prediction of an adsorption heat pump with multi-cooling tubes

    International Nuclear Information System (INIS)

    Wang, D.C.; Zhang, J.P.

    2009-01-01

    Widespread application of adsorption heat pumps has been delayed not only by poor heat and mass transfer performance but also by low operating reliability because high vacuum must be maintained in the adsorption cooling system, especially in a water system. An adsorption cooling tube is a tube in which an adsorber, a condenser and an evaporator are all completely housed to construct a small scale adsorption cooling unit. In this work, an adsorption cooling tube and an adsorption heat pump with multi-cooling tubes are designed. A theoretical model is built to simulate the performance of the designed chiller. According to the results, the coefficient of performance and specific cooling power reach about 0.5 and 85 W/kg adsorbent, respectively, at the hot water temperature of 85 deg. C. These results indicate that the designed heat pump in this work would provide a better choice if the operating reliability became crucial for an adsorption heat pump.

  5. Passive annual heat storage principles in earth sheltered housing, a supplementary energy saving system in residential housing

    Energy Technology Data Exchange (ETDEWEB)

    Anselm, Akubue Jideofor [Green Architecture Department, School of Architecture and Urban Planning, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2008-07-01

    This paper looks through the many benefits of earth not only as a building element in its natural form but as a building mass, energy pack and spatial enclosure which characterized by location, unique physical terrain and climatic factors can be utilized in developing housing units that will provide the needed benefits of comfort alongside the seasons. Firstly the study identifies existing sunken earth houses in the North-west of China together with identifying the characters that formed the ideas behind the choice of going below the ground. Secondly, the study examines the pattern of heat exchange, heat gains and losses as to identify the principles that makes building in earth significant as an energy conservation system. The objective of this, is to relate the ideas of sunken earth home design with such principles as the passive annual heat storage systems (PAHS) in producing houses that will serve as units used to collect free solar heat all summer and cools passively while heating the earth around it and also keeping warm in winter by retrieving heat from the soil while utilizing the free solar heat stored throughout the summer as a year-round natural thermal resource. (author)

  6. Effects of housing system on the costs of commercial egg production1

    Science.gov (United States)

    Matthews, W. A.; Sumner, D. A.

    2014-01-01

    This article reports the first publicly available egg production costs compared across 3 hen-housing systems. We collected detailed data from 2 flock cycles from a commercial egg farm operating a conventional barn, an aviary, and an enriched colony system at the same location. The farm employed the same operational and accounting procedures for each housing system. Results provide clear evidence that egg production costs are much higher for the aviary system than the other 2 housing systems. Feed costs per dozen eggs are somewhat higher for the aviary and lower for the enriched house compared with the conventional house. Labor costs are much lower for the conventional house than the other 2, and pullet costs are much higher for the aviary. Energy and miscellaneous costs are a minimal part of total operating costs and do not differ by housing system. Total capital investments per hen-capacity are much higher for the aviary and the enriched house. Capital costs per dozen eggs depend on assumptions about appropriate interest and depreciation rates. Using the same 10% rate for each housing system shows capital costs per dozen for the aviary and the enriched housing system are much higher than capital costs per dozen for the conventional house. The aviary has average operating costs (feed, labor, pullet, energy, and miscellaneous costs that recur for each flock and vary with egg production) about 23% higher and average total costs about 36% higher compared with the conventional house. The enriched housing system has average operating costs only about 4% higher compared with the conventional house, but average total costs are 13% higher than for the conventional house. PMID:25480736

  7. Javanese House’s Roof (Joglo) with the Opening as a Cooling Energy Provider

    Science.gov (United States)

    Pranoto S, M.

    2018-01-01

    Natural ventilation and air movement could be considered under the heading structural controls as it does not rely on any form of energy supply or mechanical installation but due to its importance for human comfort, it deserves a separate section. Air infiltration can destroy the performance of ventilation systems. Good ventilation design combined with optimum air tightness is needed to ensure energy efficient ventilation. Ultimately, ventilation needs depend on occupancy pattern and building use. A full cost and energy analysis is therefore needed to select an optimum ventilation strategy.The contains of paper is about the element of Javanese house (the roof) as the element of natural ventilation and a cooling energy provider. In this research, The Computational Fluid Dynamics Program, is used to draw and analysis. That tool can be track the pattern and the direction of movement of air also the air velocity in the object of ventilation of the roof Javanese house based. Finally, the ventilation of the roof of this Javanese house can add the velocity of air at indoor, average 0.4 m/s and give the effect of cooling, average 0.7°C.

  8. Effects of total integrated solar radiation on radial fruit cracking in tomato [Lycopersicon esculentum] cultivation under rain shelter in cool uplands

    International Nuclear Information System (INIS)

    Suzuki, T.; Yanase, S.; Enya, T.; Shimazu, T.; Tanaka, I.

    2007-01-01

    This study investigated the cause of radial fruit cracking in tomato cultivation under rain shelter in the cool uplands in Gifu Prefecture. The effect of total integrated radiation using two types of training methods was determined over a three-year period. The percentage of refused radial fruit cracking associated with increased total integrated solar radiation from the young fruit stage to the mature green stage. Fruit cracking occurred in the training method which foliage and fruits received a large amount of light-interception. Also, as for fruits that undergo vigorous enlargement, the frequency of the radial fruit cracking increased

  9. Geothermal Heat Pump System for New Student Housing Project at the University at Albany Main Campus

    Energy Technology Data Exchange (ETDEWEB)

    Lnu, Indumathi [Univ. of Albany, NY (United States)

    2015-08-27

    University at Albany successfully designed, constructed and is operating a new student housing building that utilizes ground source heat pump (GSHP) for heating and cooling the entire 191,500SF building. The installed system consists of a well field with 150 bores, 450 feet deep and (189) terminal heat pump units for a total capacity of 358 Tons cooling and 4,300 MBtu/h heating. The building opened in Fall 2012. The annual energy use and cost intensity of the building, after the changes made during the first 2 years’ of operation is 57kBtu/SF/Year and $1.30/SF/Year respectively. This is approximately 50% lower than the other residential quads on campus, despite the fact that the quads are not air-conditioned. The total project cost from design through 3-years of operations is approximately $6 Million, out of which $5.7 Million is for construction of the GSHP system including the well field. The University received a $2.78 Million grant from the Department of Energy. The estimated utility cost savings, compared to a baseline building with conventional HVAC system, is approximately $185,000. The estimated simple payback, after grant incentives, is 15 years. Additionally, the project has created 8.5FTE equivalent jobs.

  10. Biofouling control of industrial seawater cooling towers

    KAUST Repository

    Albloushi, Mohammed

    2017-11-01

    The use of seawater in cooling towers for industrial applications has much merit in the Gulf Cooperation Council countries due to the scarcity and availability of fresh water. Seawater make-up in cooling towers is deemed the most feasible because of its unlimited supply in coastal areas. Such latent-heat removal with seawater in cooling towers is several folds more efficient than sensible heat extraction via heat exchangers. Operational challenges such as scaling, corrosion, and biofouling are a major challenge in conventional cooling towers, where the latter is also a major issue in seawater cooling towers. Biofouling can significantly hamper the efficiency of cooling towers. The most popular methods used in cooling treatment to control biofouling are disinfection by chlorination. However, the disadvantages of chlorination are formation of harmful disinfection byproducts in the presence of high organic loading and safety concerns in the storage of chlorine gas. In this study, the research focuses on biofouling control in seawater cooling towers by investigating two different approaches. The first strategy addresses the use of alternative oxidants (i.e. ozone micro-bubbles and chlorine dioxide) in treatment of cooling towers. The second strategy investigates removing nutrients in seawater using granular activated carbon filter column and ultrafiltration to prevent the growth of microorganisms. Laboratory bench-scale tests in terms of temperature, cycle of concentration, dosage, etc. indicated that, at lower oxidant dosages (total residual oxidant (TRO) equivalent = 0.1 mg/l Cl2), chlorine dioxide had a better disinfection effect than chlorine and ozone. The performance of oxidizing biocides at pilot scale, operating at assorted conditions, showed that for the disinfectants tested, ozone could remove 95 % bioactivity of total number of bacteria and algae followed by chlorine dioxide at 85%, while conventional chlorine dosing only gave 60% reduction in bioactivities

  11. Liquid metal cooling of synchrotron optics

    International Nuclear Information System (INIS)

    Smither, R.K.

    1993-01-01

    The installation of insertion devices at existing synchrotron facilities around the world has stimulated the development of new ways to cool the optical elements in the associated x-ray beamlines. Argonne has been a leader in the development of liquid metal cooling for high heat load x-ray optics for the next generation of synchrotron facilities. The high thermal conductivity, high volume specific heat, low kinematic viscosity, and large working temperature range make liquid metals a very efficient heat transfer fluid. A wide range of liquid metals were considered in the initial phase of this work. The most promising liquid metal cooling fluid identified to date is liquid gallium, which appears to have all the desired properties and the fewest number of undesired features of the liquid metals examined. Besides the special features of liquid metals that make them good heat transfer fluids, the very low vapor pressure over a large working temperature range make liquid gallium an ideal cooling fluid for use in a high vacuum environment. A leak of the liquid gallium into the high vacuum and even into very high vacuum areas will not result in any detectable vapor pressure and may even improve the vacuum environment as the liquid gallium combines with any water vapor or oxygen present in the system. The practical use of a liquid metal for cooling silicon crystals and other high heat load applications depends on having a convenient and efficient delivery system. The requirements for a typical cooling system for a silicon crystal used in a monochromator are pumping speeds of 2 to 5 gpm (120 cc per sec to 600 cc per sec) at pressures up to 100 psi. No liquid metal pump with these capabilities was available commercially when this project was started, so it was necessary to develop a suitable pump in house

  12. Passive cooling of control rod drive mechanisms

    International Nuclear Information System (INIS)

    Hankinson, M.F.; Schwirian, R.E.

    1992-01-01

    A method and apparatus are provided for passively cooling the control rod drive mechanisms (CRDMs) in the reactor vessel of a nuclear power plant. Passive cooling is achieved by dispersing a plurality of chimneys within the CRDM array in positions where a control rod is not required. The chimneys induce convective air currents which cause ambient air from within the containment to flow over the CRDM coils. The air heated by the coils is guided into inlets in the chimneys by baffles. The chimney is insulated and extends through the seismic support platform and missile shield disposed above the closure head. A collar of adjustable height mates with plate elements formed at the distal end of the CRDM pressure housings by an interlocking arrangement so that the seismic support platform provides lateral restraint for the chimneys. (Author)

  13. Affordable house designs to improve health in rural Africa : a field study from northeastern Tanzania.

    OpenAIRE

    Von Seidlein, L.; Ikonomedis, K.; Mshamu, S.; Nkya, T.E.; Mukaka, M.; Pell, C.; Lindsay, S.W.; Deen, J.; Kisinza, W.N.; Knudsen, J.B.

    2017-01-01

    Background The population of sub-Saharan Africa is currently estimated to be 1245 million and is expected to quadruple by the end of the century, necessitating the building of millions of homes. Malaria remains a substantial problem in this region and efforts to minimise transmission should be considered in future house planning. We studied how building elements, which have been successfully employed in southeast Asia to prevent mosquitos from entering and cooling the house, could be inte...

  14. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  15. Control of cooling processes with forced-air aimed at efficiency energetic and the cooling time of horticultural products

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Joao Carlos Teles Ribeiro da; Mederos, Barbara Janet Teruel [Universidade Estadual de Campinas (FEAGRI/UNICAMP), SP (Brazil). Fac. de Engenharia Agricola

    2008-07-01

    The application of cooling technologies for the conservation of horticultural products is one of the stages the Cold Chain. In Brazil particularly, as a country with tropical climate with average high temperature almost all year, the application of these technologies is very important because the shelf-life of fresh horticultural products, with quality that the market demands, is directly related to temperature. In particular, the systems of forced air cooling operate according to the flow of air predetermined in the project according to the quantity of product to cool. When actual conditions differ from considerations of the project, as to the quantity of product, a situation very common in agricultural properties and packing houses, the fan will continue providing the nominal flow rate, causing alteration of the cost-benefit relation of process. This project aims at the development of a micro-processing equipment (output current of 4 to 20 mA) to control the rotational speed of the motor of the fan systems, air forced through an inverter of frequency. The objective is development of a Man-Machine Interface, based on an algorithm, which, through the introduction of mass product data and the automatic acquisition of data from temperature of the product and the camera, is calculated the cooling time. The rotation of the engine fan will be amended automatically, to maintain air flow with a proper cost-benefit, in connection with the reduction of cooling time, energy consumption, for the increasing the shelf life of products. (author)

  16. Analysis of Natural Ventilation in a Passive House Located in Cold Conditions

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2013-01-01

    in Vejle during cooling season, in the months of June, July and August. The dwelling belongs to a Danish project of passive houses denominated Komfort Husene, where its occupants claim there is no thermal comfort in summer time. The results show that the use of natural ventilation helps to reduce......This article shows the potential of using natural ventilation as a passive method of cooling buildings that are located in cold climate countries using Denmark as a case study. The energy saving potential of natural ventilation is found by performing thermal simulations of a household located...

  17. Device and method of cooling control rod drives

    International Nuclear Information System (INIS)

    Togashi, Hidetoshi; Mase, Noriaki; Matsumura, Yuichi.

    1985-01-01

    Purpose: To prevent the generation of local temperature rise depending on the reactor core position of the control rod drives and control the temperature to an averaged state in BWR type reactors. Method: Control rod drives having a large charging length of the housing in the pressure vessel involve such a factor that the temperature of the control rod drives is increased by the synergistic effect due to the radiation heat from the reactor core and to the unevenness of the cooling water flow rate, which renders an appropriate temperature control difficult for the reactor core position. A cooling water flow rate controlling device having a restriction mechanism is disposed on the cooling water feed path for each of the hydraulic control units of the control rod drives, so that flow rate to the control rod drives is increased at the center of the reactor core and decreased at the periphery thereof. As a result, average temperature state can be set, temperature increase due to cloggings can be prevented and the thermal effect can be eliminated to thereby improve the reliability. (Moriyama, K.)

  18. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for new detached houses); 1994 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu. Shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-30

    This report describes the fiscal 1974 result on the solar cooling/heating and hot water supply system. The report includes the system analysis result (collection of existing technical data, analysis of weather conditions, profitability assessment, concept design of the primary experimental house), and the research result on equipment and materials (view and evaluation of existing technologies, selective transparent and absorption materials, the primary prototype solar heat collector model, refrigerator). As the study result, the spheroidal experimental house was adopted. The solar heat utilization system is a central air-conditioning equipment composed of heating by hot water obtained from the solar heat collector, and cooling by absorption refrigerator. Heat collection efficiencies were measured for (1) stainless steel substrate collector, (2) copper substrate collector, and (3) glass pipe collector prepared as prototype collectors. (2) was higher in heat collection efficiency than (1). The efficiency of (3) hardly increased by rise in heat collection temperature due to vacuum structure and selective absorption membrane. Further measurement of such characteristics is necessary at higher temperatures. (NEDO)

  19. Does stimulant use impair housing outcomes in low-demand supportive housing for chronically homeless adults?

    Science.gov (United States)

    Edens, Ellen L; Tsai, Jack; Rosenheck, Robert A

    2014-01-01

    Recent research suggests low-demand housing (i.e., not contingent upon abstinence) is effective in helping people exit homelessness, even among recent active substance users. Whether active users of illicit drugs and stimulants have worse housing outcomes than primary alcohol users, however, is unknown. A total of 149 participants in a multisite supportive housing program who reported high levels of active substance use at program entry were classified as either (1) predominantly "Alcohol Use" (>10 of 30 days alcohol, but not >10 days of drug use) or (2) "Illicit Drug Use" (>10 of 30 days any single illicit drug use with or without alcohol use). Sub-analysis of the "Illicit Drug Use" group compared participants reporting high levels of "Stimulant Use" (>10 days cocaine, crack, or methamphetamine use) to those with high levels of "Non-stimulant Use" (>10 days marijuana or other non-stimulant drug use). Group differences in housing outcomes were examined with mixed model multivariate regression. During 24-month follow-up, days housed increased dramatically for both the "Alcohol Use" and the "Illicit Drug Use" groups without significant differences. Sub-analysis of illicit drug users showed stimulant use was associated with fewer days housed (p = .01) and more days homeless (p = .02) over time. Among illicit drug users, stimulant users have somewhat less successful housing outcomes than other active drug and alcohol users, though both groups maintained substantial housing improvements in low-demand housing. © American Academy of Addiction Psychiatry.

  20. IEA SHC Task 37: advanced housing renovation - Final report; IEA SHC Task 37: advanced housing renovation - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hastings, R.

    2010-01-15

    This final report for the Swiss Federal Office of Energy (SFOE) reports on work done within the framework of the International Energy Agency's Solar Heating and Cooling program. The project addressed the energy consumption of residential buildings and their renovation. The report discusses the goals set for the project and reports on five projects that were initiated. These include the refurbishment of apartment buildings to meet the 'Passive House' standard, air-tightness, potential for the use of solar energy, solar facades and the renovation of historic listed buildings. Conclusions resulting from these projects are presented and discussed.

  1. Heat Transfer and Cooling Techniques at Low Temperature

    CERN Document Server

    Baudouy, B

    2014-07-17

    The first part of this chapter gives an introduction to heat transfer and cooling techniques at low temperature. We review the fundamental laws of heat transfer (conduction, convection and radiation) and give useful data specific to cryogenic conditions (thermal contact resistance, total emissivity of materials and heat transfer correlation in forced or boiling flow for example) used in the design of cooling systems. In the second part, we review the main cooling techniques at low temperature, with or without cryogen, from the simplest ones (bath cooling) to the ones involving the use of cryocoolers without forgetting the cooling flow techniques.

  2. Heat Transfer and Cooling Techniques at Low Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Baudouy, B [Saclay (France)

    2014-07-01

    The first part of this chapter gives an introduction to heat transfer and cooling techniques at low temperature. We review the fundamental laws of heat transfer (conduction, convection and radiation) and give useful data specific to cryogenic conditions (thermal contact resistance, total emissivity of materials and heat transfer correlation in forced or boiling flow for example) used in the design of cooling systems. In the second part, we review the main cooling techniques at low temperature, with or without cryogen, from the simplest ones (bath cooling) to the ones involving the use of cryocoolers without forgetting the cooling flow techniques.

  3. Venus Mobile Explorer with RPS for Active Cooling: A Feasibility Study

    Science.gov (United States)

    Leifer, Stephanie D.; Green, Jacklyn R.; Balint, Tibor S.; Manvi, Ram

    2009-01-01

    We present our findings from a study to evaluate the feasibility of a radioisotope power system (RPS) combined with active cooling to enable a long-duration Venus surface mission. On-board power with active cooling technology featured prominently in both the National Research Council's Decadal Survey and in the 2006 NASA Solar System Exploration Roadmap as mission-enabling for the exploration of Venus. Power and cooling system options were reviewed and the most promising concepts modeled to develop an assessment tool for Venus mission planners considering a variety of future potential missions to Venus, including a Venus Mobile Explorer (either a balloon or rover concept), a long-lived Venus static lander, or a Venus Geophysical Network. The concepts modeled were based on the integration of General Purpose Heat Source (GPHS) modules with different types of Stirling cycle heat engines for power and cooling. Unlike prior investigations which reported on single point design concepts, this assessment tool allows the user to generate either a point design or parametric curves of approximate power and cooling system mass, power level, and number of GPHS modules needed for a "black box" payload housed in a spherical pressure vessel.

  4. Passive-solar directional-radiating cooling system

    Science.gov (United States)

    Hull, J.R.; Schertz, W.W.

    1985-06-27

    A radiative cooling system for use with an ice-making system having a radiating surface aimed at the sky for radiating energy at one or more wavelength bands for which the atmosphere is transparent and a cover thermally isolated from the radiating surface and transparent at least to the selected wavelength or wavelengths, the thermal isolation reducing the formation of condensation on the radiating surface and/or cover and permitting the radiation to continue when the radiating surface is below the dewpoint of the atmosphere, and a housing supporting the radiating surface, cover and heat transfer means to an ice storage reservoir.

  5. Investigation of the impact of using thermal mass with the net zero energy town house in Toronto using TRNSYS

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqui, O.; Fung, A.; Tse, H.; Zhang, D. [Ryerson Polytechnic Univ., Toronto, ON (Canada). Dept. of Mechanical and Industrial Engineering

    2008-07-01

    Since buildings in Canada account for 30 per cent of the country's total energy consumption, it has become necessary to find ways to reduce the overall energy use in buildings. Heating and cooling loads in buildings can be effectively reduced by using the thermal mass incorporated into the building envelope, particularly in climates where a large daily temperature fluctuations exist. Thermal mass is defined as any building material that has a high heat storage capacity that can be integrated into the structural fabric of the building to use the passive solar energy for heating or cooling purposes. Concrete slabs, bricks and ceramic blocks are some of the commonly used materials. This study analyzed the impact of using thermal mass with a highly insulated building envelope such as that used in Low Energy or Net Zero housing. In particular, TRNSYS was used to simulate a Net Zero Energy Town House located in Toronto, in which a ground source heat pump was integrated with an infloor radiant heating system. The simulation revealed that for colder climates such as in Canada, thermal mass can replace some of the insulation while still providing excellent results in terms of the reductions in daily indoor temperature fluctuations. The impact of thermal mass during the winter was more significant when compared with summer, possibly because of the unique construction and orientation of the Net Zero Energy House. The optimum thickness of the concrete slab was determined to be 6 inches for the winter season and 4 inches for summer. The optimum location for the thermal mass was found to be right next to the gypsum wallboard that forms the interior part of the wall. 12 refs., 1 tab., 11 figs.

  6. Carbon dioxide production in animal houses

    DEFF Research Database (Denmark)

    Pedersen, Søren; Blanes-Vidal, Victoria; Joergensen, H.

    2008-01-01

    cellars are emptied regularly in a four weeks interval. Due to a high and variable carbon dioxide production in deep straw litter houses and houses with indoor storage of manure longer than four weeks, we do not recommend to calculate the ventilation flow based on the carbon dioxide concentration......This article deals with carbon dioxide production from farm animals; more specifically, it addresses the possibilities of using the measured carbon dioxide concentration in animal houses as basis for estimation of ventilation flow (as the ventilation flow is a key parameter of aerial emissions from...... animal houses). The investigations include measurements in respiration chambers and in animal houses, mainly for growing pigs and broilers. Over the last decade a fixed carbon dioxide production of 185 litres per hour per heat production unit, hpu (i.e. 1000 W of the total animal heat production at 20o...

  7. Phase Change Material (PCM Application in a Modernized Korean Traditional House (Hanok

    Directory of Open Access Journals (Sweden)

    Jaewook Lee

    2018-03-01

    Full Text Available Social and policy interest in the modernization and revitalization of the Korean traditional house (Hanok has increased recently in Korea but its low thermal performance is one of its weaknesses. A feasibility study was conducted to evaluate the suitability of a Phase Change Material (PCM in a modernized Hanok. The research method involved a test of the heating and cooling load reduction and Predicted Mean Vote (PMV analysis for human comfort using an Esp-r simulation adopting multi variable PCM types as the building wall composite. The influence of PCMs on reducing the building energy load was assessed as a criterion for upgrading materials and infiltration to the passive house regulation. Compared to the base case, the heating and cooling load reduction ratio were as follows: Case 1 (old-Hanok, 10%; Case 2 (Korean Building Act, 21%; and Case 3 (passive house regulation, 53%. The optimal phase change temperatures of the PCMs were Case 1 (24–26 °C, Case 2 (23–25 °C and Case 3 (24–26 °C. PMV analysis showed that the use of a PCM can narrow the comfort range and centralize the optimal point. Therefore, the following contents can be presented as the design and material guidelines. First, the optimal PCM temperature can vary according to the combination of materials and local climate. In addition, the infiltration and insulation should be verified and a certain portion of them should be secured. Finally, the addition of insulation to a passive house level should be considered actively using a PCM as a supplement for net zero energy building (nZEB.

  8. Biofouling control of industrial seawater cooling towers

    KAUST Repository

    Al-Bloushi, Mohammed

    2017-01-01

    In this study, the research focuses on biofouling control in seawater cooling towers by investigating two different approaches. The first strategy addresses the use of alternative oxidants (i.e. ozone micro-bubbles and chlorine dioxide) in treatment of cooling towers. The second strategy investigates removing nutrients in seawater using granular activated carbon filter column and ultrafiltration to prevent the growth of microorganisms. Laboratory bench-scale tests in terms of temperature, cycle of concentration, dosage, etc. indicated that, at lower oxidant dosages (total residual oxidant (TRO) equivalent = 0.1 mg/l Cl2), chlorine dioxide had a better disinfection effect than chlorine and ozone. The performance of oxidizing biocides at pilot scale, operating at assorted conditions, showed that for the disinfectants tested, ozone could remove 95 % bioactivity of total number of bacteria and algae followed by chlorine dioxide at 85%, while conventional chlorine dosing only gave 60% reduction in bioactivities. Test results of GAC bio-filter showed that around 70 % removal of total organic carbon in the seawater feed was achieved and was effective in keeping the microbial growth to a minimum. The measured results from this study enable designers of seawater cooling towers to manage the biofouling problems when such cooling towers are extrapolated to a pilot scale.

  9. Stand-alone photovoltaic (PV) integrated with earth to air heat exchanger (EAHE) for space heating/cooling of adobe house in New Delhi (India)

    International Nuclear Information System (INIS)

    Chel, Arvind; Tiwari, G.N.

    2010-01-01

    This paper deals with an experimental outdoor annual performance evaluation of 2.32 kW P photovoltaic (PV) power system located at solar energy park in New Delhi composite climatic conditions. This PV system operates the daily electrical load nearly 10 kW h/day which comprises of various applications such as electric air blower of an earth to air heat exchanger (EAHE) used for heating/cooling of adobe house, ceiling fan, fluorescent tube-light, computer, submersible water pump, etc. The outdoor efficiencies, power generated and lost in PV system components were determined using hourly experimental measured data for 1 year on typical clear day in each month. These realistic data are useful for design engineers for outdoor assessment of PV system components. The energy conservation, mitigation of CO 2 emission and carbon credit potential of the existing PV integrated EAHE system is presented in this paper. Also, the energy payback time (EPBT) and unit cost of electricity were determined for both stand-alone PV (SAPV) and building roof integrated PV (BIPV) systems.

  10. Innovation Incubator: LiquidCool Solutions Technical Evaluation. Laboratory Study and Demonstration Results of a Directed-Flow, Liquid Submerged Server for High-Efficiency Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, Eric J [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-12-12

    LiquidCool Solutions (LCS) has developed liquid submerged server (LSS) technology that changes the way computer electronics are cooled. The technology provides an option to cool electronics by the direct contact flow of dielectric fluid (coolant) into a sealed enclosure housing all the electronics of a single server. The intimate dielectric fluid contact with electronics improves the effectiveness of heat removal from the electronics.

  11. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Fenaughty, Karen [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States); Lubliner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States)

    2018-01-15

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies amongst regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  12. Field and Laboratory Testing of Approaches to Smart Whole-House Mechanical Ventilation Control

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Florida Solar Energy Center, Cocoa, FL (United States); Fenaughty, Karen [Florida Solar Energy Center, Cocoa, FL (United States); Parker, Danny [Florida Solar Energy Center, Cocoa, FL (United States); Lubiner, Michael [Washington State Univ., Pullman, WA (United States); Howard, Luke [Washington State Univ., Pullman, WA (United States)

    2018-01-29

    Whole-house mechanical ventilation is a critical component to a comprehensive strategy for good indoor air quality (IAQ). However, due to lack of integration with standard heating and cooling systems, and perceptions from a portion of the homebuilding industry about risks related to increased energy use, increased cost, and decreased comfort, voluntary and code-required adoption varies among regions. Smart ventilation controls (SVC) balance energy consumption, comfort, and IAQ by optimizing mechanical ventilation operation to reduce the heating and/or cooling loads, improve management of indoor moisture, and maintain IAQ equivalence according to ASHRAE 62.2.

  13. Five-minute grid of total marine bird biomass densities surveyed off central California - selected cool water temperature periods, 1980-2001 (CDAS data set AL3_MASS.shp)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — AL3_MASS is a polygon shapefile representing 5 minute x 5 minute latitude x longitude cells that house the overall total biomass densities (kg/sq km) of up to 76...

  14. Shanghai housing reform. Program a burden on foreign investors.

    Science.gov (United States)

    Burke, F

    1991-09-23

    This document contains a summary of the Housing Reform Program created in Shanghai, China, in 1991, which requires monthly contributions of all employers and employees in Shanghai to a "Collective Reserve Fund." The program also applies to foreign investment enterprises and must be followed by all enterprises, regardless of any previous housing benefits that an enterprise may be providing its employees. Employers must deduct 5% from each employee's salary (with a minimum) monthly and must match that amount. The total is paid into an account in the employer's name with the People's Construction Bank of China. The total amount collected and matched for an employee is considered the property of the employee, but the account is administered by the employer as a collective trust account. Each employee's balance may be withdrawn upon retirement, leaving the area, or purchasing a home and leaving state-owned housing. Foreign investment enterprises contribute a reduced amount in recognition of the fact that they pay salaries that are higher than those of state enterprises. The Housing Reform Program also requires employers to contribute to doubled rent subsidies for public housing, requires workers to purchase housing construction bonds in order to be eligible for newly allocated public housing, calles for housing to be sold at favorable prices, and creates a system whereby mortgages can be obtained from the Collective Reserve Fund.

  15. Fiscal 1974 Sunshine Project result report. R and D on solar cooling/heating and hot water supply system (R and D on the system for existing detached houses); 1974 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Kison kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-05-28

    This report describes the fiscal 1974 research result on solar cooling/heating and hot water supply systems for existing detached houses. The program for calculating heat collection rates was prepared by integrating peripheral conditions and every calculation step of heat collection rate, mean value, accumulated value and changes caused by disturbance. The cooling/heating load calculation program was also prepared for unsteady dynamic thermal analysis of houses. Another program was prepared for hot water supply load because of a large difference in life pattern. The profitability and energy conservation of 644 systems different in heat source, heat discharge, heat collection, heat storage, auxiliary heat source and equipment were evaluated by heat balance calculation program. Survey and study were also made on various heat engines such as heat pump, absorption refrigerator and Rankine cycle engine. Based on the survey result on existing technology for plane collectors, the optimum design method of collectors were established through various characteristic tests. Some kinds of suitable fusion latent heat type heat media were selected, and their operation stabilities were studied. (NEDO)

  16. Analysis of the thermal behaviour of a low cost, single-family, more sustainable house in Porto Alegre, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Grigoletti, Giane [Departamento de Arquitetura e Urbanismo, UFSM, Santa Maria, RS (Brazil); Nucleo Orientado para a Inovacao da Edificacao, UFRGS, Porto Alegre (Brazil); Sattler, Miguel A.; Morello, Alessandro [Nucleo Orientado para a Inovacao da Edificacao, UFRGS, Porto Alegre (Brazil)

    2008-07-01

    Efforts have been made in Brazil to improve the thermal performance of low-cost buildings. Since 1997 studies on low-cost housing have been developed by Nucleo Orientado para a Inovacao da Edificacao, the construction sector of the Engineering College of the Rio Grande do Sul University, Brazil. In 2000 a prototype of a low-cost house was built on the university campus. This prototype has undergone several evaluations in an attempt to assess its thermal and environmental performance, like: energy consumption, rainwater harvesting, use of sustainably managed wood for window frames and doors, besides a detailed accounting of overall costs. The thermal performance of the house was monitored, by recording outdoor and indoor air temperatures and relative humidity, over the period of whole year. A brief appraisal of such results, as well as the annual heating and cooling degree-hours are presented. Daily swings in outdoor are a common climatic event in Porto Alegre and the building response to daily temperature swings, greater than 10 K, and hot and cold spells are presented. The results show that the thermal performance of the prototype is fairly satisfactory, considering the limitations of a low-cost house, when artificial heating and cooling is not affordable. (author)

  17. Passive cooling containment study

    International Nuclear Information System (INIS)

    Shin, J.J.; Iotti, R.C.; Wright, R.F.

    1993-01-01

    Pressure and temperature transients of nuclear reactor containment following postulated loss of coolant accident with a coincident station blackout due to total loss of all alternating current power are studied analytically and experimentally for the full scale NPR (New Production Reactor). All the reactor and containment cooling under this condition would rely on the passive cooling system which removes reactor decay heat and provides emergency core and containment cooling. Containment passive cooling for this study takes place in the annulus between containment steel shell and concrete shield building by natural convection air flow and thermal radiation. Various heat transfer coefficients inside annular air space were investigated by running the modified CONTEMPT code CONTEMPT-NPR. In order to verify proper heat transfer coefficient, temperature, heat flux, and velocity profiles were measured inside annular air space of the test facility which is a 24 foot (7.3m) high, steam heated inner cylinder of three foot (.91m) diameter and five and half foot (1.7m) diameter outer cylinder. Comparison of CONTEMPT-NPR and WGOTHIC was done for reduced scale NPR

  18. Film cooling adiabatic effectiveness measurements of pressure side trailing edge cooling configurations

    Directory of Open Access Journals (Sweden)

    R. Becchi

    2015-12-01

    Full Text Available Nowadays total inlet temperature of gas turbine is far above the permissible metal temperature; as a consequence, advanced cooling techniques must be applied to protect from thermal stresses, oxidation and corrosion the components located in the high pressure stages, such as the blade trailing edge. A suitable design of the cooling system for the trailing edge has to cope with geometric constraints and aerodynamic demands; state-of-the-art of cooling concepts often use film cooling on blade pressure side: the air taken from last compressor stages is ejected through discrete holes or slots to provide a cold layer between hot mainstream and the blade surface. With the goal of ensuring a satisfactory lifetime of blades, the design of efficient trailing edge film cooling schemes and, moreover, the possibility to check carefully their behavior, are hence necessary to guarantee an appropriate metal temperature distribution. For this purpose an experimental survey was carried out to investigate the film covering performance of different pressure side trailing edge cooling systems for turbine blades. The experimental test section consists of a scaled-up trailing edge model installed in an open loop suction type test rig. Measurements of adiabatic effectiveness distributions were carried out on three trailing edge cooling system configurations. The baseline geometry is composed by inclined slots separated by elongated pedestals; the second geometry shares the same cutback configuration, with an additional row of circular film cooling holes located upstream; the third model is equipped with three rows of in-line film cooling holes. Experiments have been performed at nearly ambient conditions imposing several blowing ratio values and using carbon dioxide as coolant in order to reproduce a density ratio close to the engine conditions (DR=1.52. To extend the validity of the survey a comparison between adiabatic effectiveness measurements and a prediction by

  19. Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids

    Science.gov (United States)

    Marsh, Jan H.; Messmann, Stephen John; Scribner, Carmen Andrew

    2017-10-25

    A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be used to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.

  20. Water spray cooling technique applied on a photovoltaic panel: The performance response

    International Nuclear Information System (INIS)

    Nižetić, S.; Čoko, D.; Yadav, A.; Grubišić-Čabo, F.

    2016-01-01

    Highlights: • An experimental study was conducted on a monocrystalline photovoltaic panel (PV). • A water spray cooling technique was implemented to determine PV panel response. • The experimental results showed favorable cooling effect on the panel performance. • A feasibility aspect of the water spray cooling technique was also proven. - Abstract: This paper presents an alternative cooling technique for photovoltaic (PV) panels that includes a water spray application over panel surfaces. An alternative cooling technique in the sense that both sides of the PV panel were cooled simultaneously, to investigate the total water spray cooling effect on the PV panel performance in circumstances of peak solar irradiation levels. A specific experimental setup was elaborated in detail and the developed cooling system for the PV panel was tested in a geographical location with a typical Mediterranean climate. The experimental result shows that it is possible to achieve a maximal total increase of 16.3% (effective 7.7%) in electric power output and a total increase of 14.1% (effective 5.9%) in PV panel electrical efficiency by using the proposed cooling technique in circumstances of peak solar irradiation. Furthermore, it was also possible to decrease panel temperature from an average 54 °C (non-cooled PV panel) to 24 °C in the case of simultaneous front and backside PV panel cooling. Economic feasibility was also determined for of the proposed water spray cooling technique, where the main advantage of the analyzed cooling technique is regarding the PV panel’s surface and its self-cleaning effect, which additionally acts as a booster to the average delivered electricity.

  1. Living in some of the first Danish Passive Houses

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla

    2012-01-01

    The pilot project, named Comfort Houses, aims to show the industry that it is possible to construct traditional Danish houses as passive houses and promote them as comfortable houses. For this to be a success in the future, it is necessary to fulfil the occupants’ wants and needs. This study aims...... to communicate how the occupants of the Comfort Houses experience living in a passive house and illustrate how their behaviour affect the performance of the house. This is done through qualitative interviews with the occupants compared with quantitative measurements of the performance of the Comfort Houses....... A total of 3 residential units have been examined and the results show that the occupants’ everyday lives have changed – some as a result of the architectural and structural solutions, others as a result of the technology integrated in the houses. The study determines the importance of considering...

  2. Cryogenics for the MuCool Test Area (MTA)

    International Nuclear Information System (INIS)

    Darve, Christine; Norris, Barry; Pei, Liujin

    2006-01-01

    MuCool Test Area (MTA) is a complex of buildings at Fermi National Accelerator Laboratory, which are dedicated to operate components of a cooling cell to be used for Muon Collider and Neutrino Factory R and D. The long-term goal of this facility is to test ionization cooling principles by operating a 25-liter liquid hydrogen (LH2) absorber embedded in a 5 Tesla superconducting solenoid magnet. The MTA solenoid magnet will be used with RF cavities exposed to a high intensity beam. Cryogens used at the MTA include LHe, LN2 and LH2. The latter dictates stringent system design for hazardous locations. The cryogenic plant is a modified Tevatron refrigerator based on the Claude cycle. The implementation of an in-house refrigerator system and two 300 kilowatt screw compressors is under development. The helium refrigeration capacity is 500 W at 14 K. In addition the MTA solenoid magnet will be batch-filled with LHe every 2 days using the same cryo-plant. This paper reviews cryogenic systems used to support the Muon Collider and Neutrino Factory R and D programs and emphasizes the feasibility of handling cryogenic equipment at MTA in a safe manner

  3. 75 FR 4100 - Affirmative Fair Housing, Marketing (AFHM) Plan-Multifamily Housing, Affirmative Fair Housing...

    Science.gov (United States)

    2010-01-26

    ... DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT [Docket No. FR-5376-N-01] Affirmative Fair Housing, Marketing (AFHM) Plan-Multifamily Housing, Affirmative Fair Housing Marketing (AFHM) Plan-Single Family Housing and Affirmative Fair Housing Marketing (AFHM) Plan- Cooperatives/Condominiums AGENCY: Office of...

  4. Thermoelectric air-cooling module for electronic devices

    International Nuclear Information System (INIS)

    Chang, Yu-Wei; Chang, Chih-Chung; Ke, Ming-Tsun; Chen, Sih-Li

    2009-01-01

    This article investigates the thermoelectric air-cooling module for electronic devices. The effects of heat load of heater and input current to thermoelectric cooler are experimentally determined. A theoretical model of thermal analogy network is developed to predict the thermal performance of the thermoelectric air-cooling module. The result shows that the prediction by the model agrees with the experimental data. At a specific heat load, the thermoelectric air-cooling module reaches the best cooling performance at an optimum input current. In this study, the optimum input currents are from 6 A to 7 A at the heat loads from 20 W to 100 W. The result also demonstrates that the thermoelectric air-cooling module performs better performance at a lower heat load. The lowest total temperature difference-heat load ratio is experimentally estimated as -0.54 W K -1 at the low heat load of 20 W, while it is 0.664 W K -1 at the high heat load of 100 W. In some conditions, the thermoelectric air-cooling module performs worse than the air-cooling heat sink only. This article shows the effective operating range in which the cooling performance of the thermoelectric air-cooling module excels that of the air-cooling heat sink only.

  5. The Leger house: an affordable super insulated home

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2000-03-01

    Building and energy efficient house in a cost-effective manner is not an easy task. The house described in this article is a 1200 sq.ft house, built on the principle of the Arkansas house, a sophisticated example of advanced wood frame construction, meets both these requirements, i.e. it is both energy efficient and good value for the money. It is built on a cast-in place concrete foundation with advanced framing construction techniques, staggered studs spaced on 24 inch centres, on separate plates forming an eight inch thick wall. The exterior sheathing is Dow Styrofoam, over which vinyl siding is installed. Thermal bridging, which is the weak point in conventional framing, received special attention. The outer walls are placed in such a way that they do not touch the floor joist and the plywood subfloor. Windows are wood framed, double glazed, a combination of casement and double hung, with storm windows, and sliding units. The clear span roof truss design gives the freedom of an open interior allowing a continuous unbroken ceiling vapour diffusion retarder. Drywall and oak flooring was installed without interference from partitions which were installed after the ceiling and the floor were in place. All lighting fixtures are on the partitions, so there is no need for penetration of the top plates in the partitions. Similarly, there is no wiring or plumbing in the exterior walls. Insulated steel doors, with magnetic weather stripping open to two airlocks. Domestic hot water and space heating is provided by a tank-less 43,800 Btu/hr Paloma natural gas heater. The water is kept at 160 degrees F and supplied to 46 feet of baseboard. A small conventional air-conditioning unit is installed but was only used for or a total of 12 hours since 1979, since during most of the hot summer days the rooms remain satisfactorily cool at about 80 degrees F, provided doors and windows are kept shut. A heat recovery ventilator has been installed subsequently, but is not considered

  6. Liquid metal cooled nuclear reactor constructions

    International Nuclear Information System (INIS)

    Aspden, G.J.; Allbeson, K.F.

    1984-01-01

    In a liquid metal cooled nuclear reactor with a nuclear fuel assembly in a coolant-containing primary vessel housed within a concrete containment vault, there is thermal insulation to protect the concrete, the insulation being disposed between vessel and concrete and being hung from metal structure secured to and projecting from the concrete, the insulation consisting of a plurality of adjoining units each unit incorporating a pack of thermal insulating material and defining a contained void co-extensive with said pack and situated between pack and concrete, the void of each unit being connected to the voids of adjoining units so as to form continuous ducting for a fluid coolant. (author)

  7. Shading Performance on Terraced House Facades in Putrajaya, Malaysia

    Directory of Open Access Journals (Sweden)

    Hassan Ahmad Sanusi

    2015-01-01

    Full Text Available This study evaluates shading performance on house facades of selected three terraced houses in Putrajaya, Malaysia as the case studies. Terraced house type is selected for the case study because it is the most popular house type built in this country to house an increase of the urban population. Its total number built in urban area increases from 27% of the total dwellings in 1980 to 40% in 1990, and to slightly more than 60 per cent in 2000. The Case Study A, B, and C are atypical style of terraced house facade designs built in Putrajaya. These postmodern designs exhibit a range of complex geometric elements blending of colonial and traditional elements with colorful styles on the house facade. In this study, the time at which the sun path perpendicular to the house facade will be used to gain the results of shading performances when the house facades have their maximum exposure to the direct sunlight. The house facade was divided into two main parts which are opaque and glazing surface elements. The amount of shading area on the opaque and glazing surface was simulated using the SunTool program. In conclusion, the Case Study C had the highest average percentage of the shading area, which is 64.43%, followed by the Case Study A 60.41% and Case Study B 56.29%. These results showed that the facade designs had excellent horizontal shading elements with roof overhangs for high angle sunlight but they had weak vertical shading elements due to a lack of considerations of louvered elements to block low angle sunlight.

  8. Quantitative Study of Green Area for Climate Sensitive Terraced Housing Area Design in Malaysia

    International Nuclear Information System (INIS)

    Yeo, O T S; Saito, K; Said, I

    2014-01-01

    Neighbourhood plays a significant role in peoples' daily lives. Nowadays, terraced housing is common in Malaysia, and green areas in the neighborhood are not used to their maximum. The aim of the research is to quantify the types of green area that are most efficient for cooling the environment for thermal comfort and mitigation of Urban Heat Island. Spatial and environmental inputs are manipulated for the simulation using Geographic Information System (GIS) integrated with computational microclimate simulation. The outcome of this research is a climate sensitive housing environment model framework on the green area to solve the problem of Urban Heat Island

  9. Building America Industrialized Housing Partnership (BAIHP)

    Energy Technology Data Exchange (ETDEWEB)

    McIlvaine, Janet; Chandra, Subrato; Barkaszi, Stephen; Beal, David; Chasar, David; Colon, Carlos; Fonorow, Ken; Gordon, Andrew; Hoak, David; Hutchinson, Stephanie; Lubliner, Mike; Martin, Eric; McCluney, Ross; McGinley, Mark; McSorley, Mike; Moyer, Neil; Mullens, Mike; Parker, Danny; Sherwin, John; Vieira, Rob; Wichers, Susan

    2006-06-30

    This final report summarizes the work conducted by the Building America Industrialized Housing Partnership (www.baihp.org) for the period 9/1/99-6/30/06. BAIHP is led by the Florida Solar Energy Center of the University of Central Florida and focuses on factory built housing. In partnership with over 50 factory and site builders, work was performed in two main areas--research and technical assistance. In the research area--through site visits in over 75 problem homes, we discovered the prime causes of moisture problems in some manufactured homes and our industry partners adopted our solutions to nearly eliminate this vexing problem. Through testing conducted in over two dozen housing factories of six factory builders we documented the value of leak free duct design and construction which was embraced by our industry partners and implemented in all the thousands of homes they built. Through laboratory test facilities and measurements in real homes we documented the merits of 'cool roof' technologies and developed an innovative night sky radiative cooling concept currently being tested. We patented an energy efficient condenser fan design, documented energy efficient home retrofit strategies after hurricane damage, developed improved specifications for federal procurement for future temporary housing, compared the Building America benchmark to HERS Index and IECC 2006, developed a toolkit for improving the accuracy and speed of benchmark calculations, monitored the field performance of over a dozen prototype homes and initiated research on the effectiveness of occupancy feedback in reducing household energy use. In the technical assistance area we provided systems engineering analysis, conducted training, testing and commissioning that have resulted in over 128,000 factory built and over 5,000 site built homes which are saving their owners over $17,000,000 annually in energy bills. These include homes built by Palm Harbor Homes, Fleetwood, Southern Energy

  10. Percutaneous radiofrequency ablation of osteoid osteoma using cool-tip electrodes without the cooling system

    International Nuclear Information System (INIS)

    Miyazaki, Masaya; Miyazaki, Akiko; Nakajima, Takahito; Koyama, Yoshinori; Shinozaki, Tetsuya; Endo, Keigo; Aoki, Jun

    2011-01-01

    The aim of this study was to evaluate the efficacy of percutaneous radiofrequency ablation (RFA) for osteoid osteoma (OO) using cool-tip electrodes without the cooling system. A total of 17 patients (13 males, 4 females; mean age 19.1 years; range 7-49 years) with OO (tibia, n=7; femur, n=5; acetabulum, n=2; radius, n=1; talus, n=1; lumbar spine, n=1) underwent RFA. Using a cool-tip electrode without the cooling system, the lesion was heated to 90degC for 4 or 5 min. Procedures were considered technically successful if the electrode was placed into the nidus and the target temperature was reached and maintained for at least 4 min. Clinical success of the treatment was defined as complete or partial pain relief after RFA. All procedures were considered technically successful, although two patients encountered complications (pes equinus contracture, skin burn). Altogether, 16 of the 17 patients (94.1%) achieved complete or partial pain relief after primary RFA. Two patients had pain recurrence, with one of them treated successfully with a second RFA. The overall clinical success rate was 88.2%. Histological findings confirmed the presence of OO in 13 patients (76.5%). Percutaneous RFA of OO using cool-tip electrodes without the cooling system is a safe, effective procedure. (author)

  11. Energy plus standard in buildings constructed by housing associations?

    International Nuclear Information System (INIS)

    Stutterecker, Werner; Blümel, Ernst

    2012-01-01

    In order to achieve national, European and international energy goals, energy efficiency strategies in the building sector have to be implemented. The passive house standard and low energy standards are already successfully established in single dwelling houses. These high performance standards are starting to penetrate into the sector of housing associations. A case study about an apartment building constructed by a housing association is presented here. It describes the monitoring concept and the results of the 1st year of monitoring. Depending on the definition of the zero energy building standard (extent of loads included in the balancing), the building could be classified as an energy plus building or as a building, which uses more energy, than is supplied by on-site generation. If the building's total energy use (including user specific loads) is defined as load, only 34.5% of these loads were provided by the net energy output of the PV system. If only the heating energy demand is defined as load, the PV system even yielded a surplus of 45.6% of the energy load. -- Highlights: ► Energy monitoring of an apartment building constructed by a housing association. ► Planned as a Passive House with a semi-central ventilation system with decentralized heat pump technology. ► Total end energy demand of the building was 43 kWh/(m² a). ► Total net energy generation by the PV system was 15 kWh/(m² a). ► Apartment no. 1: 52% of the energy demand were used for heating and ventilation.

  12. Autonomous houses. Autonomous house

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, S. (Tokai University, Tokyo (Japan). Faculty of Engineering)

    1991-09-30

    Self-sufficiency type houses are outlined. On condition that people gain a certain amount of income in relation with the society, they self-suffice under the given environment, allowing themselves to accept a minimum of industrial products with small environmental load. Ordinary supply from outside of fossil energy and materials which depend on it is minimized. Types are classified into three: energy, energy materials and perfect self-sufficiency. A study project for environment symbiotic houses is progressing which is planned by the Ministry of Construction and Institute of Building Energy Conservation and is invested by a private company. Its target is making a house for halving an environmental load by CO{sub 2}, for the purpose of creating the environment symbiotic house which is nice to and in harmony with the global environment and human beings. As a part of the studies on energy-saving and resource conservation on houses, introduced is a plan of an autonomous house at Izu-Atagawa. The passive method and high thermal-insulation are used for air conditioning, and hot spring water for hot water supply. Electric power is generated by hydroelectric power generation using mountain streams and by solar cells. Staple food is purchased, while subsidiary food is sufficed. 17 refs., 4 figs., 1 tab.

  13. Building a 40% Energy Saving House in the Mixed-Humid Climate

    Energy Technology Data Exchange (ETDEWEB)

    Christian, Jeffrey E [ORNL; Bonar, Jacob [ORNL

    2011-10-01

    This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar

  14. Snowball Vs. House-to-House Technique for Measuring Annual Incidence of Kala-azar in the Higher Endemic Blocks of Bihar, India: A Comparison.

    Science.gov (United States)

    Siddiqui, Niyamat A; Rabidas, Vidya N; Sinha, Sanjay K; Verma, Rakesh B; Pandey, Krishna; Singh, Vijay P; Ranjan, Alok; Topno, Roshan K; Lal, Chandra S; Kumar, Vijay; Sahoo, Ganesh C; Sridhar, Srikantaih; Pandey, Arvind; Das, Pradeep

    2016-09-01

    Visceral Leishmaniasis, commonly known as kala-azar, is widely prevalent in Bihar. The National Kala-azar Control Program has applied house-to-house survey approach several times for estimating Kala-azar incidence in the past. However, this approach includes huge logistics and operational cost, as occurrence of kala-azar is clustered in nature. The present study aims to compare efficiency, cost and feasibility of snowball sampling approach to house-to-house survey approach in capturing kala-azar cases in two endemic districts of Bihar, India. A community based cross-sectional study was conducted in two highly endemic Primary Health Centre (PHC) areas, each from two endemic districts of Bihar, India. Snowball technique (used to locate potential subjects with help of key informants where subjects are hard to locate) and house-to-house survey technique were applied to detect all the new cases of Kala-azar during a defined reference period of one year i.e. June, 2010 to May, 2011. The study covered a total of 105,035 households with 537,153 populations. Out of total 561 cases and 17 deaths probably due to kala-azar, identified by the study, snowball sampling approach captured only 221 cases and 13 deaths, whereas 489 cases and 17 deaths were detected by house-to-house survey approach. Higher value of McNemar's χ² statistics (64; phouse-to-house survey approach than snowball sampling and relative difference (>1) indicates that most of the kala-azar cases missed by snowball sampling were captured by house-to-house approach with 13% of omission. Snowball sampling was not found sensitive enough as it captured only about 50% of VL cases. However, it captured about 77% of the deaths probably due to kala-azar and was found more cost-effective than house-to-house approach. Standardization of snowball approach with improved procedure, training and logistics may enhance the sensitivity of snowball sampling and its application in national Kala-azar elimination programme as cost

  15. Pre-Design of Transitional Rural Housing for Syria with Recycled Rubble from Destroyed Buildings

    Science.gov (United States)

    Morishita, Naomi; Haj Ismail, Salah; Cetin, Rukiye

    2017-10-01

    The scale of destruction caused by seven years of on-going war in Syria has caused mass migration of the Syrian people within and outside of Syria. The situation calls for a means to provide the internally displaced persons (IDPs) within Syria with humane post-war affordable housing that can be quickly and easily built with few resources. Fossil fuel resources are not only scarce because of the war, but are also being used as a valuable commodity to finance the war economy, and thus, housing should minimize consumption of energy for heating and cooling because of the fossil fuel scarcity while providing high thermal comfort to the inhabitants. The housing parameters for the proposed solution are to integrate as much of the local building materials in the Aleppo region as possible using existing regional building traditions. Imported products such as building materials, machinery, equipment, as well as foreign labour and knowhow are to be kept to a minimum while incorporating recycled rubble from destroyed buildings. A comparative study of current disaster relief housing illustrates the appropriateness of each design solution in relation to the above-proposed housing parameters. A detailed analysis of the physical properties of an existing case study building in Dabiq, a town 40 km northeast of Aleppo, outlines the strengths and weaknesses of the building tradition to determine which aspects of the construction may be improved for better thermal comfort and resistance against earthquakes. The simulation results from WUFI Plus show the building behaviour of the case study house. This paper offers a concept for transitional single-family housing for IDPs based upon the adobe tradition in the rural areas of Aleppo. Reducing the heating and cooling loads can also drastically reduce fossil fuel requirements during the construction and operation phases of the single-family homes while maintaining a high level of indoor thermal comfort. Traditional construction techniques

  16. Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing

    DEFF Research Database (Denmark)

    Helle, Tina

    and adapted according to accessibility norms and guidelines for housing design in Sweden, Denmark, Iceland and Finland. This iterative process involved occupational therapists, architects, building engineers and professional translators, resulting in the Nordic Housing Enabler. For reliability testing...... serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from the original Swedish version......, the sample strategy and data collection procedures were the same in all countries. In total, twenty voluntary occupational therapists collected data from 106 cases by means of the Nordic Housing Enabler. Inter-rater reliability was calculated by means of percentage agreement and kappa statistics. Overall...

  17. Thermal Storage Systems Assessment for Energy Sustainability in Housing Units

    Directory of Open Access Journals (Sweden)

    Tania I. Lagunes Vega

    2016-04-01

    Full Text Available In order to achieve greater enhancements in energy sustainability for housing, the function and efficiency of two different passive cooling systems were studied: encapsulated water in recycled bottles of Polyethylene terephthalate (PET and polystyrene plates, in comparison with standard concrete slab systems, which are customarily used in housing. Experiments were placed over a tile surface, in which temperature changes were monitored for a period of 20 days from 08:00 to 20:00. The efficiency of passive thermal storage systems was endorsed through statistical analysis using the “SPSS” software. This resulted in a 17% energy saving, thus promoting energy sustainability in housing units, which reduces the use of electrical appliances required to stabilize conditions to achieve optimum thermal comfort for the human body inside a house, therefore, reducing electrical power consumption, CO2 emissions to the atmosphere and generating savings. Due to the complexity of a system with temperature changes, a fractal analysis was performed for each experimental system, using the “Benoit” software (V.1.3 with self-compatible tools of rescaled range (R/S and a wavelets method, showing that the thermal fluctuations on the tiles with the thermal storage system adapt to the rescaled range analysis and the regular tiles adapt to the wavelets method.

  18. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, A.; Stecher, D.

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, Pennsylvania. Four air-based heating, ventilation, and air conditioning distribution systems--a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms--were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  19. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States); Stecher, Dave [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  20. Integrated cooling system for the Mirror Fusion Test Facility

    International Nuclear Information System (INIS)

    Johnson, B.; Chang, Y.

    1979-01-01

    The MFTF components that require water cooling include the neutral beam dumps, ion dumps, plasma dumps, baffle plates, magnet liners, gas boxes, streaming guns, and the neutral beam injectors. A total heat load of nearly 500 MW for 0.5 s dissipates over 4-min intervals. A steady-flow, closed-loop system is utilized. The design of the cooling system assumes that all components require cooling simultaneously. The cooling system contains process instrumentation for loop control. Alarms and safety interlocks are incorporated for the safe operation of the system

  1. Simulation of solar lithium bromide-water absorption cooling system with parabolic trough collector

    International Nuclear Information System (INIS)

    Mazloumi, M.; Naghashzadegan, M.; Javaherdeh, K.

    2008-01-01

    Ahwaz is one of the sweltering cities in Iran where an enormous amount of energy is being consumed to cool residential places in a year. The aim of this research is to simulate a solar single effect lithium bromide-water absorption cooling system in Ahwaz. The solar energy is absorbed by a horizontal N-S parabolic trough collector and stored in an insulated thermal storage tank. The system has been designed to supply the cooling load of a typical house where the cooling load peak is about 17.5 kW (5 tons of refrigeration), which occurs in July. A thermodynamic model has been used to simulate the absorption cycle. The working fluid is water, which is pumped directly to the collector. The results showed that the collector mass flow rate has a negligible effect on the minimum required collector area, but it has a significant effect on the optimum capacity of the storage tank. The minimum required collector area was about 57.6 m 2 , which could supply the cooling loads for the sunshine hours of the design day for July. The operation of the system has also been considered after sunset by saving solar energy

  2. Core test reactor shield cooling system analysis

    International Nuclear Information System (INIS)

    Larson, E.M.; Elliott, R.D.

    1971-01-01

    System requirements for cooling the shield within the vacuum vessel for the core test reactor are analyzed. The total heat to be removed by the coolant system is less than 22,700 Btu/hr, with an additional 4600 Btu/hr to be removed by the 2-inch thick steel plate below the shield. The maximum temperature of the concrete in the shield can be kept below 200 0 F if the shield plug walls are kept below 160 0 F. The walls of the two ''donut'' shaped shield segments, which are cooled by the water from the shield and vessel cooling system, should operate below 95 0 F. The walls of the center plug, which are cooled with nitrogen, should operate below 100 0 F. (U.S.)

  3. On the thermal inertia and time constant of single-family houses

    Energy Technology Data Exchange (ETDEWEB)

    Hedbrant, J.

    2001-08-01

    Since the 1970s, electricity has become a common heating source in Swedish single-family houses. About one million small houses can use electricity for heating, about 600.000 have electricity as the only heating source, A liberalised European electricity market would most likely raise the Swedish electricity prices during daytime on weekdays and lower it at other times. In the long run, electrical heating of houses would be replaced by fuels, but in the shorter perspective, other strategies may be considered. This report evaluates the use of electricity for heating a dwelling, or part of it, at night when both the demand and the price are low. The stored heat is utilised in the daytime some hours later, when the electricity price is high. Essential for heat storage is the thermal time constant. The report gives a simple theoretical framework for the calculation of the time constant for a single-family house with furniture. Furthermore the comfort time constant, that is, the time for a house to cool down from a maximum to a minimum acceptable temperature, is derived. Two theoretical model houses are calculated, and the results are compared to data from empirical studies in three inhabited test houses. The results show that it was possible to store about 8 kWh/K in a house from the seventies and about 5 kWh/K in a house from the eighties. The time constants were 34 h and 53 h, respectively. During winter conditions with 0 deg C outdoor, the 'comfort' time constants with maximum and minimum indoor temperatures of 23 and 20 deg C were 6 h and 10 h. The results indicate that the maximum load-shifting potential of an average single family house is about 1 kw during 16 daytime hours shifted into 2 kw during 8 night hours. Upscaled to the one million Swedish single-family houses that can use electricity as a heating source, the maximum potential is 1000 MW daytime time-shifted into 2000 MW at night.

  4. Housing markets and housing policies in India

    OpenAIRE

    Tiwari, Piyush; Rao, Jyoti

    2016-01-01

    Issues of housing in India are synonymous with ignorance of housing in active government involvement at the policy and program formulation levels. They are also due to the problems that unplanned urbanization, income disparity, poverty, illiteracy, and unemployment brought. These issues extenuated the housing problem, causing a housing shortage of 51 million in 2011. Though India has a long history of establishing policies, programs, and institutions to cater to housing, without allocating ad...

  5. Asset management strategies and sustainability in Dutch social housing

    NARCIS (Netherlands)

    Nieboer, N.E.T.

    2004-01-01

    With 35% of the total housing stock in the Netherlands (Ministry of VROM, 2004), the social rented sector plays an important role in Dutch housing, and its management can be of great importance to the success or failure of sustainability programs. Although sustainable building has been high on the

  6. Recognising the potential for renewable energy heating and cooling

    International Nuclear Information System (INIS)

    Seyboth, Kristin; Beurskens, Luuk; Langniss, Ole; Sims, Ralph E.H.

    2008-01-01

    Heating and cooling in the industrial, commercial, and domestic sectors constitute around 40-50% of total global final energy demand. A wide range of renewable energy heating and cooling (REHC) technologies exists but they are presently only used to meet around 2-3% of total world demand (excluding from traditional biomass). Several of these technologies are mature, their markets are growing, and their costs relative to conventional heating and cooling systems continue to decline. However, in most countries, policies developed to encourage the wider deployment of renewable electricity generation, transport biofuels and energy efficiency have over-shadowed policies aimed at REHC technology deployment. This paper, based on the findings of the International Energy Agency publication Renewables for Heating and Cooling-Untapped Potential, outlines the present and future markets and compares the costs of providing heating and cooling services from solar, geothermal and biomass resources. It analyses current policies and experiences and makes recommendations to support enhanced market deployment of REHC technologies to provide greater energy supply security and climate change mitigation. If policies as successfully implemented by the leading countries were to be replicated elsewhere (possibly after modification to better suit local conditions), there would be good potential to significantly increase the share of renewable energy in providing heating and cooling services

  7. Modelization of cooling system components

    Energy Technology Data Exchange (ETDEWEB)

    Copete, Monica; Ortega, Silvia; Vaquero, Jose Carlos; Cervantes, Eva [Westinghouse Electric (Spain)

    2010-07-01

    results in relatively low water withdrawal. Typical heat sink options for closed-cycle systems are wet cooling system (mechanical or natural draft cooling towers, and cooling ponds). When water availability is low, a dry cooling system may be utilized. Dry cooling can be either direct or indirect and in each case uses convective heat transfer to provide cooling, eliminating evaporation losses. An innovative indirect dry cooling system is the Heller{sup R} System. The Heller{sup R} System air moving equipment can be either a natural draft or a mechanical draft. The Heller{sup R} System design concepts and equipment provides the maximum possible availability and minimum maintenance. Also, it is totally environmental-friend as saves water equivalent to the consumption of a town of 50,000 inhabitants for each 100 MWe facilitating the licensing of power projects. (authors)

  8. Performance characteristics of counter flow wet cooling towers

    International Nuclear Information System (INIS)

    Khan, Jameel-Ur-Rehman; Yaqub, M.; Zubair, Syed M.

    2003-01-01

    Cooling towers are one of the biggest heat and mass transfer devices that are in widespread use. In this paper, we use a detailed model of counter flow wet cooling towers in investigating the performance characteristics. The validity of the model is checked by experimental data reported in the literature. The thermal performance of the cooling towers is clearly explained in terms of varying air and water temperatures, as well as the driving potential for convection and evaporation heat transfer, along the height of the tower. The relative contribution of each mode of heat transfer rate to the total heat transfer rate in the cooling tower is established. It is demonstrated with an example problem that the predominant mode of heat transfer is evaporation. For example, evaporation contributes about 62.5% of the total rate of heat transfer at the bottom of the tower and almost 90% at the top of the tower. The variation of air and water temperatures along the height of the tower (process line) is explained on psychometric charts

  9. An application of the gas-fired chilling and heating units to domestic houses

    Energy Technology Data Exchange (ETDEWEB)

    Choi, J.H.; Yang, Y.M.; Chae, J.M.; Bang, H.S.; Kwon, O.B.; Yoo, S.I.; Kim, T.H. [R and D Center, Korea Gas Co. (Korea); Lee, T.W.; Kim, T.H.; Kim, B.H.; Hwang, I.J.; Kim, J.Y.; Kim, C.D.; Park, S.J. [Korea Institute of Construction Technology (Korea)

    1999-10-01

    Following researches and considerations were performed in this study for an efficient application of gas-fired chilling and heating units to the residential buildings. (1) Status of domestic cooling and heating for residential building. (2) Various introduction schemes of outdoor unit. (3) Design exclusive area for the gas appliance and installation of it. (4) Ventilation of exhaust gas and heat. (5) Prepare the installation specifications or standards for gas-fired chilling and heating units. (6) Design technique of plumbing for cooling and heating. (7) Evaluation of unit's capacity considering the thermal load of domestic buildings. (8) Cooling and heating system with the unit. (9) Fundamental test for evaluation of applicability. (10) Actual design and construction of experimental house for an application and a demonstration of the developed gas units. (11) Field test for cooling and heating. (12) Evaluation of economic efficiency. (13) Establish a business potential. (14) Establishment of legal and systematic support, energy rate. (15) Troubleshooting in the course of development and application of the new gas appliance. 41 refs., 214 figs., 52 tabs.

  10. A comprehensive assessment of the life cycle energy demand of passive houses

    International Nuclear Information System (INIS)

    Stephan, André; Crawford, Robert H.; Myttenaere, Kristel de

    2013-01-01

    Highlights: • The life cycle energy demand of a passive house (PH) is measured over 100 years. • Embodied, operational and user transport energy demand are considered. • Embodied energy represents the highest energy consumption in all variations. • A PH might not save energy compared to a standard house. • A poorly insulated city apartment can use less energy than a best case suburban PH. - Abstract: Certifications such as the Passive House aim to reduce the final space heating energy demand of residential buildings. The latter are responsible for a significant share of final energy consumption in Europe of which nearly 70% is associated with space conditioning, notably heating. The improvement of the energy efficiency of residential buildings, in terms of space heating, can therefore reduce their total energy demand. However, most certifications totally overlook other energy requirements associated with residential buildings. Studies on passive houses do not take into consideration the embodied energy required to manufacture the building materials, especially the large amount of insulation required to achieve high operational efficiencies. At an urban scale, most passive houses are single family detached houses located in low density suburbs with a high car usage, resulting in considerable transport related energy demand. This paper analyses the total life cycle energy demand of a typical Belgian passive house, comprising embodied, operational and transport energy. It relies on a comprehensive technique developed by Stephan et al. [1] and conducts a parametric analysis as well as a comparison to alternative building types. Results show that current building energy efficiency certifications might not ensure a lower energy demand and can, paradoxically result in an increased energy consumption because of their limited scope. More comprehensive system boundaries should be used to make sure that net energy savings do occur. The embodied energy of passive

  11. 24 CFR 982.608 - Congregate housing: Voucher housing assistance payment.

    Science.gov (United States)

    2010-04-01

    ... Housing Types Congregate Housing § 982.608 Congregate housing: Voucher housing assistance payment. (a... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Congregate housing: Voucher housing assistance payment. 982.608 Section 982.608 Housing and Urban Development Regulations Relating to Housing and...

  12. Instrumentation at the Decade 80 solar house in Tucson, Arizona

    Science.gov (United States)

    1978-01-01

    Modifications, problems and solutions for the instrumentation system that occurred during the period from May through September, 1978, are described. The solar house was built to show the use of copper in home building and to demonstrate the use of solar energy to provide space heating and cooling and domestic hot water. The auxiliary energy sources are electrical resistance heating for the domestic hot water and a gas-fired boiler for space heating and operation of the adsorption air conditioning units.

  13. Proceedings: Cooling tower and advanced cooling systems conference

    International Nuclear Information System (INIS)

    1995-02-01

    This Cooling Tower and Advanced Cooling Systems Conference was held August 30 through September 1, 1994, in St. Petersburg, Florida. The conference was sponsored by the Electric Power Research Institute (EPRI) and hosted by Florida Power Corporation to bring together utility representatives, manufacturers, researchers, and consultants. Nineteen technical papers were presented in four sessions. These sessions were devoted to the following topics: cooling tower upgrades and retrofits, cooling tower performance, cooling tower fouling, and dry and hybrid systems. On the final day, panel discussions addressed current issues in cooling tower operation and maintenance as well as research and technology needs for power plant cooling. More than 100 people attended the conference. This report contains the technical papers presented at the conference. Of the 19 papers, five concern cooling tower upgrades and retrofits, five to cooling tower performance, four discuss cooling tower fouling, and five describe dry and hybrid cooling systems. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  14. Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

    Science.gov (United States)

    Lagen, Nicholas T.; Seiner, John M.

    1990-01-01

    The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

  15. Evaluation of water cooled supersonic temperature and pressure probes for application to 1366 K flows

    Science.gov (United States)

    Lagen, Nicholas; Seiner, John M.

    1990-01-01

    Water cooled supersonic probes are developed to investigate total pressure, static pressure, and total temperature in high-temperature jet plumes and thereby determine the mean flow properties. Two probe concepts, designed for operation at up to 1366 K in a Mach 2 flow, are tested on a water cooled nozzle. The two probe designs - the unsymmetric four-tube cooling configuration and the symmetric annular cooling design - take measurements at 755, 1089, and 1366 K of the three parameters. The cooled total and static pressure readings are found to agree with previous test results with uncooled configurations. The total-temperature probe, however, is affected by the introduction of water coolant, and effect which is explained by the increased heat transfer across the thermocouple-bead surface. Further investigation of the effect of coolant on the temperature probe is proposed to mitigate the effect and calculate more accurate temperatures in jet plumes.

  16. Building a sustainable future: Bioclimatic house

    Science.gov (United States)

    Gomez Mallen, Esther; Rivera Fusalba, Oriol

    2010-05-01

    demonstrated that the air can circulate between the house and the greenhouse through the windows. The heated air in the greenhouse rose through the windows into the main house. It was cooled off as it delivered heat and returned again to the greenhouse. It happened naturally due to the materials and the configuration of the house. A solar collector gathered heat from the Sun in order to heat water until 40° C, what was enough for showering, laundry, and washing dishes. Solar cells and homemade wind power unit delivered electricity to light up a small light bulb. With these experiments and building kit we explored and used natural, renewable forms of energy. These are forms of energy that we can use without damaging our natural environment and ourselves. Perhaps this kit will give students the incentive to build something on a larger scale after they have learned from the smaller scale model devices.

  17. Housing and Health: The relationship between housing conditions ...

    African Journals Online (AJOL)

    okanlawon

    2011-10-22

    Oct 22, 2011 ... Housing and Health: The relationship between housing ... The authors in chapter one, deal extensively with historical context of housing and health chronologically ... Housing and Health: Time Again for Public Health Action.

  18. Microclimate design methods for energy-saving houses on various site conditions in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Kyeong

    2008-07-09

    A small area can have several different microclimates depending on how much sunlight, shade or wind are exposed on the area. Microclimate can be influenced by inclined terrain, surfaces, and 3-dimensionally geometry such as combinations of architectural elements and annex buildings. This study investigates microclimate modification for energy-saving using design elements of Korean traditional and passive house. Microclimate analysis method in this study enables to predict temporal and spatial variances in the building geometry. A combination of passive solar heating, cold wind blocking, indoor air circulation, natural ventilation cooling and shading etc, seasonally help to form a comfort condition with less energy consumption. The passive heating and cooling controls with microclimate modification are efficient to accomplish the energy efficiency in the building. This work includes the microclimate modifications of the high-performance designs, microclimate energy-saving methods, Passive House design methods, and common physical bases in energy simulation methods. For hot and humid summer in Korea, ventilation is beneficial for convective or evaporative cooling. The air flow through a building geometry is generated by differences in air temperature and pressure. The layout of surrounding buildings acts as barriers and diverts the flow into narrower. The resulted patterns of airflow are affected more by building geometry and orientation than by air speed. A novel simulation method combining multi-zone and CFD energy simulations is used to analyze energy-saving aspects in passive and microclimate design elements. EnergyPlus is a multi-zone energy simulation tool that uses a parameterization to simplify the energy-saving problem for each zone. However, the model is not appropriate to handle variations in the building geometry since it estimates only the average value for each volume. On the contrary, CFD method with subdivided grid units is more suitable to estimate

  19. Controlled rate cooling of fungi using a stirling cycle freezer.

    Science.gov (United States)

    Ryan, Matthew J; Kasulyte-Creasey, Daiva; Kermode, Anthony; San, Shwe Phue; Buddie, Alan G

    2014-01-01

    The use of a Stirling cycle freezer for cryopreservation is considered to have significant advantages over traditional methodologies including N2 free operation, application of low cooling rates, reduction of sample contamination risks and control of ice nucleation. The study assesses the suitability of an 'N2-free' Stirling Cycle controlled rate freezer for fungi cryopreservation. In total, 77 fungi representing a broad taxonomic coverage were cooled using the N2 free cooler following a cooling rate of -1 degrees C min(-1). Of these, 15 strains were also cryopreserved using a traditional 'N2 gas chamber' controlled rate cooler and a comparison of culture morphology and genomic stability against non-cryopreserved starter cultures was undertaken. In total of 75 fungi survived cryopreservation, only a recalcitrant Basidiomycete and filamentous Chromist failed to survive. No changes were detected in genomic profile after preservation, suggesting that genomic function is not adversely compromised as a result of using 'N2 free' cooling. The results demonstrate the potential of 'N2-free' cooling for the routine cryopreservation of fungi in Biological Resource Centres.

  20. Development of a novel rotary desiccant cooling cycle with isothermal dehumidification and regenerative evaporative cooling using thermodynamic analysis method

    International Nuclear Information System (INIS)

    La, D.; Li, Y.; Dai, Y.J.; Ge, T.S.; Wang, R.Z.

    2012-01-01

    A novel rotary desiccant cooling cycle is proposed and studied using thermodynamic analysis method. The proposed cycle integrates the technologies of isothermal dehumidification and regenerative evaporative cooling, which are beneficial for irreversibility reduction. Thermodynamic investigation on the basic rotary desiccant cooling cycle shows that the exergy efficiency of the basic cycle is only 8.6%. The processes of desiccant dehumidification and evaporative cooling, which are essentially the basis for rotary desiccant cooling, affect the exergy performance of the cycle greatly and account for about one third of the total exergy destruction. The proposed cycle has potential to improve rotary desiccant cooling technology. It is advantageous in terms of both heat source utilization rate and space cooling capacity. The exergy efficiency of the new cycle is enhanced significantly to 29.1%, which is about three times that of the ventilation cycle, and 60% higher than that of the two-stage rotary desiccant cooling cycle. Furthermore, the regeneration temperature is reduced from 80 °C to about 60 °C. The corresponding specific exergy of the supply air is increased by nearly 30% when compared with the conventional cycles. -- Highlights: ► A novel rotary desiccant cooling cycle is developed using thermodynamic analysis method. ► Isothermal dehumidification and regenerative evaporative cooling have been integrated. ► The cycle is advantageous in terms of both heat source utilization rate and space cooling capacity. ► Cascaded energy utilization is beneficial for cycle performance improvement. ► Upper limits, which will be helpful to practical design and optimization, are obtained.

  1. City of Ljubljana: Its housing, population and housing conditions

    Directory of Open Access Journals (Sweden)

    Maša Filipovič

    2007-01-01

    Full Text Available The article gives an overview of key aspect of housing in Municipality of Ljubljana. The characteristics of households, of housing and their relation influence the housing situation in the city. Characteristic of housing refer mainly to quality of the dwellings, affordability and correspondence to the wishes of the inhabitants. The second important dimensions are households and their characteristics. In Europe and Slovenia increase in number of household can be observed, which in turn are becoming smaller. The housing policy has a role in establishing a balance between households and housing, i.e. ensuring that housing corresponds to the needs of individual households and to their number. For achieving this, knowledge and appropriate data are of vital importance. In the article we present the results of the Housing survey 2005. We observe housing conditions in a comparative perspective (Ljubljana in comparison to Maribor, Slovenia and selected European cities and according to three dimensions: housing fund, households and housing conditions.

  2. Department of Defense In-House RDT&E Activities

    Science.gov (United States)

    1973-10-30

    C14AINCIS0 CLINICAL AKM) LAII S1(3(31 S 01I INrccT ION IN IIUPN P41 lENT S. STUDIY OF ACUIJI RENAL I Al IllRf ANI) Al NAI 11IMYMIILIIGY. Sitlly orI...hose eserchanddevelopment, plus sc hnsa travl, ublcatons n oter ype ofservices In support of In-house funcion an M.PA. xclded romtheIn-house total

  3. Energy house - dream house

    Energy Technology Data Exchange (ETDEWEB)

    1981-07-01

    An energy house a prefabricated house with an extensive minimization of heat losses, is air-conditioned by means of a combined heating system consisting of hot water cycle and recirculating heating. The energy system is trivalent: wind power, solar energy with heat pumps and normal oil heating.

  4. Microbial analysis of meatballs cooled with vacuum and conventional cooling.

    Science.gov (United States)

    Ozturk, Hande Mutlu; Ozturk, Harun Kemal; Koçar, Gunnur

    2017-08-01

    Vacuum cooling is a rapid evaporative cooling technique and can be used for pre-cooling of leafy vegetables, mushroom, bakery, fishery, sauces, cooked food, meat and particulate foods. The aim of this study was to apply the vacuum cooling and the conventional cooling techniques for the cooling of the meatball and to show the vacuum pressure effect on the cooling time, the temperature decrease and microbial growth rate. The results of the vacuum cooling and the conventional cooling (cooling in the refrigerator) were compared with each other for different temperatures. The study shows that the conventional cooling was much slower than the vacuum cooling. Moreover, the microbial growth rate of the vacuum cooling was extremely low compared with the conventional cooling. Thus, the lowest microbial growth occurred at 0.7 kPa and the highest microbial growth was observed at 1.5 kPa for the vacuum cooling. The mass loss ratio for the conventional cooling and vacuum cooling was about 5 and 9% respectively.

  5. Loneliness in senior housing communities.

    Science.gov (United States)

    Taylor, Harry Owen; Wang, Yi; Morrow-Howell, Nancy

    2018-05-23

    There are many studies on loneliness among community-dwelling older adults; however, there is limited research examining the extent and correlates of loneliness among older adults who reside in senior housing communities. This study examines the extent and correlates of loneliness in three public senior housing communities in the St. Louis area. Data for this project was collected with survey questionnaires with a total sample size of 148 respondents. Loneliness was measured using the Hughes 3-item loneliness scale. Additionally, the questionnaire contained measures on socio-demographics, health/mental health, social engagement, and social support. Missing data for the hierarchical multivariate regression models were imputed using multiple imputation methods. Results showed approximately 30.8% of the sample was not lonely, 42.7% was moderately lonely, and 26.6% was severely lonely. In the multivariate analyses, loneliness was primarily associated with depressive symptoms. Contrary to popular opinion, our study found the prevalence of loneliness was high in senior housing communities. Nevertheless, senior housing communities could be ideal locations for reducing loneliness among older adults. Interventions should focus on concomitantly addressing both an individual's loneliness and mental health.

  6. Demonstration and Validation of Corrosion-Mitigation Technologies for Mechanical Room Utility Piping and Cooling-Tower Pumps

    Science.gov (United States)

    2015-05-01

    34advanced material for cooling pump shafts" Stainless steel (316 or 416 ) Floway Pump Company, Fresno, CA 316 or 416 stainless steel shafts to replace...pump 5 incorporating 316 stainless steel housing. .................................... 19 Figure 13. New pump 5 being installed...43 Figure 28. Pump 5 (316 Stainless Steel ), 12 months exposure. .......................................... 43

  7. Exergetic analysis and thermoeconomic study for a container-housed engine

    Energy Technology Data Exchange (ETDEWEB)

    Sala, J.M.; Eguia, J.; Flores, I. [Escuela Superior de Ingenieros Industriales de Bilbao, Universidad del Pais Vasco, Alameda de Urquijo, s/n 48013 Bilbao, Bizkaia (Spain); Lopez-Gonzalez, L.M.; Ruiz de Adana, M. [Escuela Tecnica Superior de Ingenieria Industrial, Universidad de La Rioja, C/Luis de Ulloa, 20. E-26004 Logrono, La Rioja (Spain); Miguez, J.L. [Universidad de Vigo, Escuela Tecnica Superior de Ingenieros Industriales, C/Lagoas-Marcosende, s/n 36200 Vigo, Pontevedra (Spain)

    2006-11-15

    This paper presents the engineering design and theoretical exergetic analyses for a container-housed reciprocating engine. The exergy analysis conducted was based on the first and second laws of thermodynamics for power generation systems. Using thermographic inspection, the heat dissipated by each one of the 28 elements under consideration in the engine container was assessed, together with the mass flow rate of air supplied to the cab and the air temperature at the inlet and outlet. This information is essential for the proper design of the ventilation system needed to disseminate the heat generated inside the container-housed unit. The energy balance and corresponding exergy balance were drawn up using the values thus obtained and the information available on the engine. The engine efficiency rates were evaluated on both an energy and exergy basis, taking into account that heat from the cooling circuit and exhaust fumes are used for CHP. Finally, thermoeconomics was applied to calculate the costs of the electricity and useful heat energy produced by the engine. The result of this study should be to optimize the design of container-housed CHP systems, showing where exergy losses occur and identifying areas of improvement. (author)

  8. Renewable energy for passive house heating. Part 1. Building description

    Energy Technology Data Exchange (ETDEWEB)

    Badescu, V. [Polytechnic Univ., Bucharest (Romania). Faculty of Mechanical Engineering; Sicre, B. [Technical Univ., Chemnitz (Germany). Computational Physics

    2003-12-01

    A passive house is a cost-efficient building that can manage throughout the heating period, due to its specific construction design, with more than 10 times less heat energy than the same building designed to standards presently applicable across Europe. Its extended thermal insulation and enhanced air-tightness removes the need for temperatures higher than 50 {sup o}C. This makes renewable energy sources particularly suitable for heating, cooling and domestic hot water production. Modeling of renewable energy usage for space heating requires as a preliminary stage the detailed description of the building structure, of the HVAC equipment and of the internal heat sources. This paper shows the main data used to model the thermal behavior of a passive house. Details about Pirmasens Passive House (Rhineland Palatinate, Germany) are given, as for example, the internal heat sources, including electric appliances, heat and humidity released by human bodies, thermal internal facilities as hot and cold water pipes. All these are quantified by using statistically derived data. A detailed time schedule for a standard German family with two adults and two children was prepared. It takes into account the national celebrations, vacation and weekends among others. (Author)

  9. Exergetic analysis and thermoeconomic study for a container-housed engine

    International Nuclear Information System (INIS)

    Sala, J.M.; Lopez-Gonzalez, L.M.; Ruiz de Adana, M.; Miguez, J.L.; Eguia, J.; Flores, I.

    2006-01-01

    This paper presents the engineering design and theoretical exergetic analyses for a container-housed reciprocating engine. The exergy analysis conducted was based on the first and second laws of thermodynamics for power generation systems. Using thermographic inspection, the heat dissipated by each one of the 28 elements under consideration in the engine container was assessed, together with the mass flow rate of air supplied to the cab and the air temperature at the inlet and outlet. This information is essential for the proper design of the ventilation system needed to disseminate the heat generated inside the container-housed unit. The energy balance and corresponding exergy balance were drawn up using the values thus obtained and the information available on the engine. The engine efficiency rates were evaluated on both an energy and exergy basis, taking into account that heat from the cooling circuit and exhaust fumes are used for CHP. Finally, thermoeconomics was applied to calculate the costs of the electricity and useful heat energy produced by the engine. The result of this study should be to optimize the design of container-housed CHP systems, showing where exergy losses occur and identifying areas of improvement

  10. Gas erosion of impeller housing in the operation of a high-temperature, high-pressure helium circulator

    International Nuclear Information System (INIS)

    Sanders, J.P.; Heestand, R.L.; Young, H.C.

    1988-01-01

    Three gas-bearing circulators are installed in series in a high-pressure, high-temperature loop to provide helium flow up to 0.47 m 3 /s at a total head of 78 kJ/kg. The design pressure is 10.7 MPa, and temperatures of 1000 deg. C can be obtained in the test section. The inlet temperature to the circulators is limited to 450 deg. C. The 200-kW motor for each circulator is enclosed in the pressure boundary, and the motor is cooled by circulating the gas within the cavity over a water-cooled coil. The full operating speed is 23,500 rpm. A full-flow filter, absolute for particulate above 10 μm, is installed upstream of the circulator to protect the gas bearing surfaces. The minimum clearances between these surfaces during operation are in the range of 15 to 30 μm. During a routine examination of the circulator, deep V-shaped grooves were found in the stationary surface of this cavity. At the same time, a very fine, dark particulate was observed in crevices of the housing. At first it was assumed that the grooves were formed by particulate erosion; however, examination of the grooves and discussions with persons experienced with large circulator operation changed this opinion. Erosion caused by particulate is characteristically rounded on the bottom and has a greater width to depth aspect than the V-shaped grooves, which were observed. Analysis of the particulate indicated that it was essentially the material of the housing that had undergone reactions with impurities in the circulating gas. It was subsequently concluded that the impeller housing had not been heat treated in a sufficiently oxidizing atmosphere after machining to form an adherent oxide coating. This suboxide coating was eroded by the shear forces in the gas. The exposed layer of metal was then further oxidized by the impurities in the gas, and these layers of oxide were successively eroded to produce the grooves. This erosion problem was eliminated by machining a ring of the same material, heat

  11. Cooling techniques

    International Nuclear Information System (INIS)

    Moeller, S.P.

    1994-01-01

    After an introduction to the general concepts of cooling of charged particle beams, some specific cooling methods are discussed, namely stochastic, electron and laser cooling. The treatment concentrates on the physical ideas of the cooling methods and only very crude derivations of cooling times are given. At the end three other proposed cooling schemes are briefly discussed. (orig.)

  12. Cost viability of 3D printed house in UK

    Science.gov (United States)

    Tobi, A. L. Mohd; Omar, S. A.; Yehia, Z.; Al-Ojaili, S.; Hashim, A.; Orhan, O.

    2018-03-01

    UK has been facing housing crisis due to the rising price of the property on sale. This paper will look into the viability of 3D printing technology as an alternative way for house construction on UK. The analysis will be carried out based on the data until the year of 2014 due to limited resources availability. Details cost breakdown on average size house construction cost in UK were analysed and relate to the cost viability of 3D printing technology in reducing the house price in UK. It is found that the 3D printing generates saving of up to around 35% out of total house price in UK. This cost saving comes from the 3D printed construction of walls and foundations for material and labour cost.

  13. Thermal evaluation for exposed stone house with quantitative and qualitative approach in mountainous area, Wonosobo, Indonesia

    Science.gov (United States)

    Hermawan, Hermawan; Prianto, Eddy

    2017-12-01

    A building can be considered as having a good thermal performance if it can make the occupant comfortable. Thermal comfort can be seen from the occupant's respond toward the architectural elements and the environment, such as lighting, the room crowding, air temperature, humidity, oxygen level, and occupant's behaviours. The objective of this research is to analyse the thermal performance of four different orientation houses in mountainous area. The research was conducted on the four expose stone houses with four different orientations in the slope of Sindoro Mountain which has relative cool temperature, about 26°C. The measurement of the elements above was done quantitatively and qualitatively for 24 hours. The results are as follows. First, the most comfortable house is west-orientation house. Second, based on the quantitative and qualitative observation, there is no significant difference (±5 %). Third, the occupant's behaviours (caring and genen) also become factors influencing occupant's comfort.

  14. Research on seasonal indoor thermal environment and residents' control behavior of cooling and heating systems in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Chihye; Chun, Chungyoon [Department of Housing and Interior Design, College of Human Ecology, Graduate School, Yonsei University, Seoul (Korea)

    2009-11-15

    Indoor thermal environments and residents' control behavior of cooling and heating systems were investigated in Seoul, Korea and compared with the results of previous studies. Twenty-four houses in summer, six houses in autumn and 36 houses in winter were used in this study. The measurement of temperature, humidity and air conditioner usage behavior was carried out. The clo-value, thermal comfort, sensation and basic data of the houses were also investigated. The indoor thermal environment in the summer had a high temperature and a high humidity ratio compare to standard comfort zone. Most of the indoor thermal environments at the time of starting the air conditioner in the summer were out of the comfort zone. Some of the data recorded while the air conditioner was stopped were in the comfort zone, but in many cases the temperature was relatively higher than comfort zone. Most indoor climate distributions in the winter were in the comfort zone and the indoor climate in autumn coincided well with the criteria of the comfort zone. Compared with results of previous studies in these 25 years, indoor ambient average temperature in winter has increased and the comfort temperature has increased in the heating period and decreased in the cooling period. This result indicates that the development of an HVAC system has created an expectation of comfort for residents and has shifted their thermal comfort zone warmer in winter and cooler in summer. (author)

  15. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Conlin, Francis [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Podorson, David [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States); Alaigh, Kunal [Advanced Residential Integrated Energy Solutions (ARIES) Collaborative, New York, NY (United States)

    2014-06-01

    More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation 10 ten housing units. Total source energy consumption savings was estimated at 6%-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

  16. A powerful way of cooling computer chip using liquid metal with low melting point as the cooling fluid

    Energy Technology Data Exchange (ETDEWEB)

    Li Teng; Lv Yong-Gang [Chinese Academy of Sciences, Beijing (China). Cryogenic Lab.; Chinese Academy of Sciences, Beijing (China). Graduate School; Liu Jing; Zhou Yi-Xin [Chinese Academy of Sciences, Beijing (China). Cryogenic Lab.

    2006-12-15

    With the improvement of computational speed, thermal management becomes a serious concern in computer system. CPU chips are squeezing into tighter and tighter spaces with no more room for heat to escape. Total power-dissipation levels now reside about 110 W, and peak power densities are reaching 400-500 W/mm{sup 2} and are still steadily climbing. As a result, higher performance and greater reliability are extremely tough to attain. But since the standard conduction and forced-air convection techniques no longer be able to provide adequate cooling for sophisticated electronic systems, new solutions are being looked into liquid cooling, thermoelectric cooling, heat pipes, and vapor chambers. In this paper, we investigated a novel method to significantly lower the chip temperature using liquid metal with low melting point as the cooling fluid. The liquid gallium was particularly adopted to test the feasibility of this cooling approach, due to its low melting point at 29.7 C, high thermal conductivity and heat capacity. A series of experiments with different flow rates and heat dissipation rates were performed. The cooling capacity and reliability of the liquid metal were compared with that of the water-cooling and very attractive results were obtained. Finally, a general criterion was introduced to evaluate the cooling performance difference between the liquid metal cooling and the water-cooling. The results indicate that the temperature of the computer chip can be significantly reduced with the increasing flow rate of liquid gallium, which suggests that an even higher power dissipation density can be achieved with a large flow of liquid gallium and large area of heat dissipation. The concept discussed in this paper is expected to provide a powerful cooling strategy for the notebook PC, desktop PC and large computer. It can also be extended to more wide area involved with thermal management on high heat generation rate. (orig.)

  17. A local-community-level, physically-based model of end-use energy consumption by Australian housing stock

    International Nuclear Information System (INIS)

    Ren Zhengen; Paevere, Phillip; McNamara, Cheryl

    2012-01-01

    We developed a physics based bottom-up model to estimate annual housing stock energy consumption at a local community level (Census Collection District—CCD) with an hourly resolution. Total energy consumption, including space heating and cooling, water heating, lighting and other household appliances, was simulated by considering building construction and materials, equipment and appliances, local climates and occupancy patterns. The model was used to analyse energy use by private dwellings in more than five thousand CCDs in the state of New South Wales (NSW), Australia. The predicted results focus on electricity consumption (natural gas and other fuel sources were excluded as the data are not available) and track the actual electricity consumption at CCD level with an error of 9.2% when summed to state level. For NSW and Victoria 2006, the predicted state electricity consumption is close to the published model (within 6%) and statistical data (within 10%). A key feature of the model is that it can be used to predict hourly electricity consumption and peak demand at fine geographic scales, which is important for grid planning and designing local energy efficiency or demand response strategies. - Highlights: ► We developed a physics-based model to estimate housing stock energy consumption. ► House type and vintage, family type and occupancy time were considered. ► The model results are close to actual energy consumption at local community level. ► Its’ results agree well with the published model and statistical data at state level. ► It shows the model could provide from hourly to annual residential energy consumption.

  18. Cryogen spray cooling during laser tissue welding.

    Science.gov (United States)

    Fried, N M; Walsh, J T

    2000-03-01

    Cryogen cooling during laser tissue welding was explored as a means of reducing lateral thermal damage near the tissue surface and shortening operative time. Two centimetre long full-thickness incisions were made on the epilated backs of guinea pigs, in vivo. India ink was applied to the incision edges then clamps were used to appose the edges. A 4 mm diameter beam of 16 W, continuous-wave, 1.06 microm, Nd:YAG laser radiation was scanned over the incisions, producing approximately 100 ms pulses. There was a delay of 2 s between scans. The total irradiation time was varied from 1-2 min. Cryogen was delivered to the weld site through a solenoid valve in spurt durations of 20, 60 and 100 ms. The time between spurts was either 2 or 4 s, corresponding to one spurt every one or two laser scans. Histology and tensile strength measurements were used to evaluate laser welds. Total irradiation times were reduced from 10 min without surface cooling to under 1 min with surface cooling. The thermal denaturation profile showed less denaturation in the papillary dermis than in the mid-dermis. Welds created using optimized irradiation and cooling parameters had significantly higher tensile strengths (1.7 +/- 0.4 kg cm(-2)) than measured in the control studies without cryogen cooling (1.0 +/- 0.2 kg cm(-2)) (p laser welding results in increased weld strengths while reducing thermal damage and operative times. Long-term studies will be necessary to determine weld strengths and the amount of scarring during wound healing.

  19. Design of cooling towers by the effectiveness-NTU method

    International Nuclear Information System (INIS)

    Jaber, H.; Webb, R.L.

    1989-01-01

    This paper develops the effectiveness-NTU, number of transfer units, design method for cooling towers. The definitions for effectiveness and NTU are totally consistent with the fundamental definitions used in heat exchanger design. Sample calculations are presented for counter and crossflow cooling towers. Using the proper definitions, a person competent in heat transfer design can easily use the same basic method to design a cooling tower of counter, cross, or parallel flow configuration. The problems associated with the curvature of the saturated air enthalpy line are also treated. A one-increment design ignores the effect of this curvature. Increased precision can be obtained by dividing the cooling range into two or more increments. The standard effectiveness-NYU method is then used for each of the increments. Calculations are presented to define the error associated with different numbers of increments. This defines the number of increments required to attain a desired degree of precision. The authors also summarize the LMED method introduced by Berman, and show that this is totally consistent with the effectiveness-NTU method. Hence, using proper and consistent terms, heat exchanger designers are shown how to use either the standard Log-Mean Enthalpy Method (LMED) or effectiveness-NTU design methods to design cooling towers

  20. Investigations on passive containment cooling

    International Nuclear Information System (INIS)

    Knebel, J.U.; Cheng, X.; Neitzel, H.J.; Erbacher, F.J.; Hofmann, F.

    1997-01-01

    The composite containment design for advanced LWRs that has been examined under the PASCO project is a promising design concept for purely passive decay heat removal after a severe accident. The passive cooling processes applied are natural convection and radiative heat transfer. Heat transfer through the latter process removes at an emission coefficient of 0.9 about 50% of the total heat removed via the steel containment, and thus is an essential factor. The heat transferring surfaces must have a high emission coefficient. The sump cooling concept examined under the SUCO project achieves a steady, natural convection-driven flow from the heat source to the heat sink. (orig./CB) [de

  1. 75 FR 63194 - Notice of Proposed Information Collection Comment Request Housing Trust Fund

    Science.gov (United States)

    2010-10-14

    ... Housing Finance Regulatory Reform Act of 2008, as amended, established the Housing Trust Fund (HTF... of total new business for Freddie Mac and Fannie Mae to be allocated as a dedicated source of annual funding for the HTF, unless allocations are suspended by the Director of the Federal Housing Finance...

  2. Upgrade energy building standards and develop rating system for existing low-income housing

    International Nuclear Information System (INIS)

    Muller, D.; Norville, C.

    1993-07-01

    The city of Memphis Division of Housing and Community Development (HCD) receives grant funding each year from the U.S. Department of Housing and Urban Development (HUD) to provide local housing assistance to low-income residents. Through the years, HCD has found that many of the program recipients have had difficulty in managing their households, particularly in meeting monthly financial obligations. One of the major operating costs to low-income households is the utility bill. Furthermore, HCD's experience has revealed that many low-income residents are simply unaware of ways to reduce their utility bill. Most of the HCD funds are distributed to low-income persons as grants or no/low interest loans for the construction or rehabilitation of single-family dwellings. With these funds, HCD builds 80 to 100 new houses and renovates about 500 homes each year. Houses constructed or renovated by HCD must meet HUD's minimum energy efficiency standards. While these minimum standards are more than adequate to meet local building codes, they are not as aggressive as the energy efficiency standards being promoted by the national utility organizations and the home building industry. Memphis Light, Gas and Water (MLGW), a city-owned utility, has developed an award-winning program named Comfort Plus which promotes energy efficiency open-quote in new residential construction. Under Comfort Plus, MLGW models house plans on computer for a fee and recommends cost-effective alterations which improve the energy efficiency of the house. If the builder agrees to include these recommendations, MLGW will certify the house and guarantee a maximum annual heating/cooling bill for two years. While the Comfort Plus program has received recognition in the new construction market, it does not address the existing housing stock

  3. Upgrade energy building standards and develop rating system for existing low-income housing

    Energy Technology Data Exchange (ETDEWEB)

    Muller, D.; Norville, C. [Memphis and Shelby County Div. of Planning and Development, TN (United States)

    1993-07-01

    The city of Memphis Division of Housing and Community Development (HCD) receives grant funding each year from the U.S. Department of Housing and Urban Development (HUD) to provide local housing assistance to low-income residents. Through the years, HCD has found that many of the program recipients have had difficulty in managing their households, particularly in meeting monthly financial obligations. One of the major operating costs to low-income households is the utility bill. Furthermore, HCD`s experience has revealed that many low-income residents are simply unaware of ways to reduce their utility bill. Most of the HCD funds are distributed to low-income persons as grants or no/low interest loans for the construction or rehabilitation of single-family dwellings. With these funds, HCD builds 80 to 100 new houses and renovates about 500 homes each year. Houses constructed or renovated by HCD must meet HUD`s minimum energy efficiency standards. While these minimum standards are more than adequate to meet local building codes, they are not as aggressive as the energy efficiency standards being promoted by the national utility organizations and the home building industry. Memphis Light, Gas and Water (MLGW), a city-owned utility, has developed an award-winning program named Comfort Plus which promotes energy efficiency{open_quote} in new residential construction. Under Comfort Plus, MLGW models house plans on computer for a fee and recommends cost-effective alterations which improve the energy efficiency of the house. If the builder agrees to include these recommendations, MLGW will certify the house and guarantee a maximum annual heating/cooling bill for two years. While the Comfort Plus program has received recognition in the new construction market, it does not address the existing housing stock.

  4. Influence of Shading on Cooling Energy Demand

    Science.gov (United States)

    Rabczak, Sławomir; Bukowska, Maria; Proszak-Miąsik, Danuta; Nowak, Krzysztof

    2017-10-01

    The article presents an analysis of the building cooling load taking into account the variability of the factors affecting the size of the heat gains. In order to minimize the demand for cooling, the effect of shading elements installed on the outside on the windows and its effect on size of the cooling capacity of air conditioning system for the building has been estimated. Multivariate building cooling load calculations to determine the size of the reduction in cooling demand has derived. Determination of heat gain from the sun is laborious, but gives a result which reflects the influence of the surface transparent partitions, devices used as sunscreen and its location on the building envelope in relation to the world, as well as to the internal heat gains has great attention in obtained calculation. In this study, included in the balance sheet of solar heat gains are defined in three different shading of windows. Calculating the total demand cooling is made for variants assuming 0% shading baffles transparent, 50% shading baffles transparent external shutters at an angle of 45 °, 100% shading baffles transparent hours 12 from the N and E and from 12 from the S and W of the outer slat blinds. The calculation of the average hourly cooling load was taken into account the option assuming the hypothetical possibility of default by up to 10% of the time assumed the cooling season temperatures in the rooms. To reduce the consumption of electricity energy in the cooling system of the smallest variant identified the need for the power supply for the operation of the cooling system. Also assessed the financial benefits of the temporary default of comfort.

  5. Use of radiometer to reform and repair an old living house to passive solar one

    Science.gov (United States)

    Okamoto, Yoshizo; Inagaki, Terumi; Suzuki, Takakazu; Kurokawa, Takashi

    1994-03-01

    Japanese living houses mainly consist of wooden elements in high-temperature and moist conditions. To modify the hot and humid environment, a conventional old house was partially rebuilt and repaired. Especially in the winter season, a diagnostic thermographic test was used to find deteriorated and leaking parts of interior and exterior walls. Macroscopic deteriorated parts were checked again in detail. The deteriorated element was then removed. During the reconstruction process, a new solar heat and air conditioning system using a silica-gel adsorber and underground water was installed to cool and warm up the living room. Thermography tests of this remodeled house show that room temperature is always constant and mild to human beings, especially in the winter. Temperature and heat flow distribution of flowing air in the living room was measured using thermal net and wire methods. Leaking thermal streak flow of the gap was locally visualized by the IR radiometer and a highly sensitive video camera. It was verified that IR thermography is a useful measuring instrument to check thermal defects of a house.

  6. Simulation and optimisation of a ground source heat pump with different ground heat exchanger configurations for a single-family residential house

    DEFF Research Database (Denmark)

    Pavlov, Georgi Krasimiroy; Olesen, Bjarne W.

    2012-01-01

    In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low-temperature h....... For the studied geographical location, passive cooling by bypassing the heat pump and using only the ground heat exchanger can provide acceptable room temperatures.......In the future there will be an increased demand for energy efficient cooling of residential buildings. Therefore it is essential to develop cooling concepts that are passive and/or using very little primary energy. A possible solution is a ground source heat pump combined with a low......-temperature heating and high-temperature cooling system. The present work evaluates the performance in relation to thermal comfort and energy consumption of a GSHP with different GHE concepts. The different configurations are analyzed being part of the energy supply system of a low-energy residential house...

  7. Fire behaviour of cooling tower packing; Brandverhalten von Kuehlturmeinbauten

    Energy Technology Data Exchange (ETDEWEB)

    Mattausch, Tim [DMT GmbH und Co. KG, Dortmund (Germany). Fachstelle fuer Brandschutz

    2013-10-01

    The rapid burning down of the cooling tower of the shutdown power plant in Schwandorf revealed the potential of a total loss of a cooling tower in case of fire. VGB ordered a research project in order to obtain more knowledge about the fire risk of cooling tower packing currently applied. Depending on kind and age of the plastics used, the results of these tests manifest a big variation of the fire behaviour. For the applications of plastics, it is essential to determine and to adhere to organisational fire protection measures. (orig.)

  8. 7 CFR 1944.664 - Housing preservation and replacement housing assistance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Housing preservation and replacement housing...) RURAL HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE (CONTINUED) PROGRAM REGULATIONS (CONTINUED) HOUSING Housing...

  9. Modular liquid-cooled helmet liner for thermal comfort

    Science.gov (United States)

    Williams, B. A.; Shitzer, A.

    1974-01-01

    A modular liquid-cooled helmet liner made of eight form-fitting neoprene patches was constructed. The liner was integrated into the sweatband of an Army SPH-4 helicopter aircrew helmet. This assembly was tested on four subjects seated in a hot (47 C), humid (40%) environment. Results indicate a marked reduction in the rate of increase of physiological body functions. Rectal temperature, weight loss, heart rate, and strain indices are all reduced to approximately 50% of uncooled levels. The cooling liner removed from 10% to 30% of total metabolic heat produced. This study also demonstrated the technical feasilibity of using a cooling liner in conjunction with a standard hard helmet. Potential applications of the cooling liner in thermally stressful environments are numerous, notably for helicopter and other aircrews.

  10. The Microbiologic Quality of the Air in Broiler Houses

    Directory of Open Access Journals (Sweden)

    Silvana Popescu

    2010-10-01

    Full Text Available The aim of this paper was to assess the microbiologic quality of air in broiler houses. The number of bacteria (mesophile, staphylococci, streptococci and gram-negatives and fungi was determined in 6 broiler houses with chicken of different ages (1-6 weeks old through specific methods. The results were statistically processed by using the SPSS software, version 17. The number of bacteria and fungi varied in the 6 broiler houses, ranging from 2.25 x 105 to 2.17 x 106 for the total number of mesophilic bacteria, between 3.5 x 104 – 1.27 x 106 for staphylococci, 7.4 x 104 – 5.01 x 105 for streptococci, 3.5 x 103 – 1.53 x 104 for gram-negatives and from 1.67 x 104 to 8.13 x 104 for fungi, respectively. The number of bacteria and fungi were significantly lower for the younger chicken (p < 0.05. The proportions of groups with hygienic significance within the total mesophilic bacteria number were: 15.7% - 68.6% staphylococci, 6.7% - 45.6% streptococci and 0.2% - 4.5% gram-negatives. The comparative appraisal of the microbiologic quality in the broiler houses showed better air quality in the youngest chicken’s house (one week of age. The obtained results indicate the necessity for increased ventilation and for air disinfection during the chicken’s fattening period.

  11. Processes influencing cooling of reactor effluents

    International Nuclear Information System (INIS)

    Magoulas, V.E.; Murphy, C.E. Jr.

    1982-01-01

    Discharge of heated reactor cooling water from SRP reactors to the Savannah River is through sections of stream channels into the Savannah River Swamp and from the swamp into the river. Significant cooling of the reactor effluents takes place in both the streams and swamp. The majority of the cooling is through processes taking place at the surface of the water. The major means of heat dissipation are convective transfer of heat to the air, latent heat transfer through evaporation and radiative transfer of infrared radiation. A model was developed which incorporates the effects of these processes on stream and swamp cooling of reactor effluents. The model was used to simulate the effect of modifications in the stream environment on the temperature of water flowing into the river. Environmental effects simulated were the effect of changing radiant heat load, the effect of changes in tree canopy density in the swamp, the effect of total removal of trees from the swamp, and the effect of diverting the heated water from L reactor from Steel Creek to Pen Branch. 6 references, 7 figures

  12. Comparing Social Stories™ to Cool versus Not Cool

    Science.gov (United States)

    Leaf, Justin B.; Mitchell, Erin; Townley-Cochran, Donna; McEachin, John; Taubman, Mitchell; Leaf, Ronald

    2016-01-01

    In this study we compared the cool versus not cool procedure to Social Stories™ for teaching various social behaviors to one individual diagnosed with autism spectrum disorder. The researchers randomly assigned three social skills to the cool versus not cool procedure and three social skills to the Social Stories™ procedure. Naturalistic probes…

  13. Understanding Housing Delays and Relocations Within the Housing First Model.

    Science.gov (United States)

    Zerger, Suzanne; Pridham, Katherine Francombe; Jeyaratnam, Jeyagobi; Hwang, Stephen W; O'Campo, Patricia; Kohli, Jaipreet; Stergiopoulos, Vicky

    2016-01-01

    This study explores factors contributing to delays and relocations during the implementation of the Housing First model in Toronto, Ontario. While interruptions in housing tenure are expected en route to recovery and housing stability, consumer and service provider views on finding and keeping housing remain largely unknown. In-person interviews and focus groups were conducted with 48 study participants, including 23 case managers or housing workers and 25 consumers. The following three factors contributed to housing delays and transfers: (1) the effectiveness of communication and collaboration among consumers and service providers, (2) consumer-driven preferences and ambivalence, and (3) provider prioritization of consumer choice over immediate housing access. Two strategies--targeted communications and consumer engagement in housing searches--supported the housing process. Several factors affect the timing and stability of housing. Communication between and among providers and consumers, and a shared understanding of consumer choice, can further support choice and recovery.

  14. Film cooling for a closed loop cooled airfoil

    Science.gov (United States)

    Burdgick, Steven Sebastian; Yu, Yufeng Phillip; Itzel, Gary Michael

    2003-01-01

    Turbine stator vane segments have radially inner and outer walls with vanes extending therebetween. The inner and outer walls are compartmentalized and have impingement plates. Steam flowing into the outer wall plenum passes through the impingement plate for impingement cooling of the outer wall upper surface. The spent impingement steam flows into cavities of the vane having inserts for impingement cooling the walls of the vane. The steam passes into the inner wall and through the impingement plate for impingement cooling of the inner wall surface and for return through return cavities having inserts for impingement cooling of the vane surfaces. At least one film cooling hole is defined through a wall of at least one of the cavities for flow communication between an interior of the cavity and an exterior of the vane. The film cooling hole(s) are defined adjacent a potential low LCF life region, so that cooling medium that bleeds out through the film cooling hole(s) reduces a thermal gradient in a vicinity thereof, thereby the increase the LCF life of that region.

  15. Housing management and maintenance practise of Dutch housing associations

    NARCIS (Netherlands)

    Straub, A.

    This paper summarises the state-of-the-art in housing management and maintenance practise of Dutch housing associations based on a survey conducted among almost all housing associations. We address the question what the current developments are in housing management and maintenance practice in the

  16. Development of the interactive model between Component Cooling Water System and Containment Cooling System using GOTHIC

    International Nuclear Information System (INIS)

    Byun, Choong Sup; Song, Dong Soo; Jun, Hwang Yong

    2006-01-01

    In a design point of view, component cooling water (CCW) system is not full-interactively designed with its heat loads. Heat loads are calculated from the CCW design flow and temperature condition which is determined with conservatism. Then the CCW heat exchanger is sized by using total maximized heat loads from above calculation. This approach does not give the optimized performance results and the exact trends of CCW system and the loads during transient. Therefore a combined model for performance analysis of containment and the component cooling water(CCW) system is developed by using GOTHIC software code. The model is verified by using the design parameters of component cooling water heat exchanger and the heat loads during the recirculation mode of loss of coolant accident scenario. This model may be used for calculating the realistic containment response and CCW performance, and increasing the ultimate heat sink temperature limits

  17. 24 CFR 92.252 - Qualification as affordable housing: Rental housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Qualification as affordable housing: Rental housing. 92.252 Section 92.252 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development HOME INVESTMENT PARTNERSHIPS PROGRAM Project Requirements § 92.252...

  18. 24 CFR 8.28 - Housing certificate and housing voucher programs.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Housing certificate and housing voucher programs. 8.28 Section 8.28 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development NONDISCRIMINATION BASED ON HANDICAP IN FEDERALLY ASSISTED PROGRAMS AND...

  19. Total Productive Maintenance at Paccar INC

    OpenAIRE

    Ştefan Farkas

    2010-01-01

    This paper reports the application of total productive maintenance method at Paccar Inc. truck’s plant in Victoria, Australia. The total productive maintenance method and total productive maintenance house are presented. The global equipment effectiveness is computed and exemplified. The production structure and organising maintenance are presented. Resultas of the variation of global equipment effectiveness and autonomous maintenance in a two weeks period of time are reported.

  20. French activities on gas cooled reactors

    International Nuclear Information System (INIS)

    Bastien, D.

    1996-01-01

    The gas cooled reactor programme in France originally consisted of eight Natural Uranium Graphite Gas Cooled Reactors (UNGG). These eight units, which are now permanently shutdown, represented a combined net electrical power of 2,375 MW and a total operational history of 163 years. Studies related to these reactors concern monitoring and dismantling of decommissioned facilities, including the development of methods for dismantling. France has been monitoring the development of HTRs throughout the world since 1979, when it halted its own HTR R and D programme. France actively participates in three CRPs set up by the IAEA. (author). 1 tab

  1. Utes for space heating and cooling in North Africa

    International Nuclear Information System (INIS)

    Nordell, B.; Grein, M. a.

    2006-01-01

    The North Africa climate is dry and warm with annual mean temperature from 15 degree centigrade to 25 degree centigrade, with a temperature difference of 20 degree centigrade between the coldest and warmest month. Heating is needed during the short winter and there is a large cooling demand during the long summer. Since the undisturbed ground temperature is equal to the annual mean air temperature, the ground is warmer than the air during the winter and colder than air during summer. This is what is required for the direct use of the ground for heating and cooling. In such systems, ground coupled heating and cooling systems, and also in storage systems, Underground Thermal Energy Storage (UTES), some kind of underground duct (PIPE) system is used to inject or extract heat from the ground. Thermal energy is then stored and recovered by heating and cooling of the ground, while the ducts are the heat exchangers with the system. The duct system could be placed horizontally or vertically (e.g. in boreholes) in the ground. In many cases heat pumps or cooling machines are included in the systems but in favourable cases, such as in the North African climate, the ground can be used directly for heating and cooling. then, only a circulation pump is used to pump water through the underground duct system with high efficiencies. Such systems can also be used for thermal energy storage, during shorter periods (diurnal) or even between the seasons. In September 2005 Sebha University and Luleu University of Technology started a Libyan Swedish collaboration to develop and implement these systems for the North African climate. Sweden has considerable experience in ground coupled systems, theoretically and practically, and there are presently more than 300.000 systems in operation in Sweden, mainly for heating. Most of these are small-scale heating systems for singe-family houses but during the last decade several hundred large-scale systems have been built for heating and cooling of

  2. A simpler, safer, higher performance cooling system arrangement for water cooled divertors

    International Nuclear Information System (INIS)

    Carelli, M.D.; Kothmann, R.E.; Green, L.; Zhan, N.J.; Stefani, F.; Roidt, R.M.

    1994-01-01

    A cooling system arrangement is presented which is specifically designed for high heat flux water cooled divertors. The motivation behind the proposed open-quotes unichannelclose quotes configuration is to provide maximum safety; this design eliminates flow instabilities liable to occur in parallel channel designs, it eliminates total blockage, it promotes cross flow to counteract the effects of partial blockage and/or local hot spots, and it is much more tolerant to the effects of debonding between the beryllium armor and the copper substrate. Added degrees of freedom allow optimization of the design, including the possibility of operating at very high heat transfer coefficients associated with nucleate boiling, while at the same time providing ample margin against departure from nucleate boiling. Projected pressure drop, pumping power, and maximum operating temperatures are lower than for conventional parallel channel designs

  3. Assessment of end-use electricity consumption and peak demand by Townsville's housing stock

    International Nuclear Information System (INIS)

    Ren, Zhengen; Paevere, Phillip; Grozev, George; Egan, Stephen; Anticev, Julia

    2013-01-01

    We have developed a comprehensive model to estimate annual end-use electricity consumption and peak demand of housing stock, considering occupants' use of air conditioning systems and major appliances. The model was applied to analyse private dwellings in Townsville, Australia's largest tropical city. For the financial year (FY) 2010–11 the predicted results agreed with the actual electricity consumption with an error less than 10% for cooling thermostat settings at the standard setting temperature of 26.5 °C and at 1.0 °C higher than the standard setting. The greatest difference in monthly electricity consumption in the summer season between the model and the actual data decreased from 21% to 2% when the thermostat setting was changed from 26.5 °C to 27.5 °C. Our findings also showed that installation of solar panels in Townville houses could reduce electricity demand from the grid and would have a minor impact on the yearly peak demand. A key new feature of the model is that it can be used to predict probability distribution of energy demand considering (a) that appliances may be used randomly and (b) the way people use thermostats. The peak demand for the FY estimated from the probability distribution tracked the actual peak demand at 97% confidence level. - Highlights: • We developed a model to estimate housing stock energy consumption and peak demand. • Appliances used randomly and thermostat settings for space cooling were considered. • On-site installation of solar panels was also considered. • Its' results agree well with the actual electricity consumption and peak demand. • It shows the model could provide the probability distribution of electricity demand

  4. Drivers for retrofit: a sociocultural approach to houses and inhabitants

    DEFF Research Database (Denmark)

    Tjørring, Lise; Gausset, Quentin

    2018-01-01

    , retrofits were investigated from the perspective of the everyday life of homeowners. Three social dimensions that played an important role when the people in the study discussed house renovation were identified and discussed: houses as part of homeowners’ life cycles and personal events; houses......Private households constitute approximately 30% of the total energy consumption in Denmark. The greatest potential for reducing energy consumption in private households is through retrofits of existing houses. One of the most common ways to promote retrofits is the act of sending an energy advisor...... as frameworks for social relations; and houses as markers of social values and status. These results indicate a need to develop new strategies to promote retrofits more effectively, which focus less on the techno-economic aspects and more on the social dimensions....

  5. Divertor cooling device

    International Nuclear Information System (INIS)

    Nakayama, Tadakazu; Hayashi, Katsumi; Handa, Hiroyuki

    1993-01-01

    Cooling water for a divertor cooling system cools the divertor, thereafter, passes through pipelines connecting the exit pipelines of the divertor cooling system and the inlet pipelines of a blanket cooling system and is introduced to the blanket cooling system in a vacuum vessel. It undergoes emission of neutrons, and cooling water in the divertor cooling system containing a great amount of N-16 which is generated by radioactivation of O-16 is introduced to the blanket cooling system in the vacuum vessel by way of pipelines, and after cooling, passes through exit pipelines of the blanket cooling system and is introduced to the outside of the vacuum vessel. Radiation of N-16 in the cooling water is decayed sufficiently with passage of time during cooling of the blanket, thereby enabling to decrease the amount of shielding materials such as facilities and pipelines, and ensure spaces. (N.H.)

  6. Projecting housing starts and softwood lumber consumption in the United States

    Science.gov (United States)

    Jeffrey P. Prestemon; David N. Wear; Karen L. Abt; Robert C. Abt

    2018-01-01

    New residential construction is a primary user of wood products in the United States; therefore, wood products projections require understanding the determinants of housing starts. We model quarterly US total, single-family, and multifamily housing starts with several model specifications, using data from 1979 to 2008, and evaluate their...

  7. Simulation and performance enhancement of the air cooling system in a DC/AC power converter station

    Energy Technology Data Exchange (ETDEWEB)

    Lozowy, R.; El-Shaboury, A.; Soliman, H.; Ormiston, S. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Mechanical and Manufacturing Engineering

    2010-07-01

    This study analyzed the flow structure and heat transfer in a large 3-dimensional domain with turbulence, mixed convection, an impinging jet, and flow over heated blocks. The objective was to better understand turbulent mixed-convection cooling of heat-generating bodies in 3-dimensional enclosures, which is important to industry. The cooling of 2 thyristor valve halls was simulated. Each valve hall housed 3 towers that contained electronics used in DC/AC power conversion. The simulation results included the magnitudes of the net air flows for all the inter-block gaps and the maximum temperature in each gap. A parametric study was also performed to investigate the effects of the air inlet location, size and aspect ratio. The effects of the air injection angle on cooling effectiveness was also examined. The study showed that for fixed inlet mass flow rate, significant improvement in the cooling effectiveness can be obtained by changing the injection angle of the inlet air jet, the location of the inlet grill, or the size of the inlet grill. It was concluded that these study results may be relevant to other applications, such as the design of power transformers, the design of cooling systems for spent nuclear fuel and computer server cooling racks. 13 refs., 12 figs.

  8. Cool colored coating and phase change materials as complementary cooling strategies for building cooling load reduction in tropics

    International Nuclear Information System (INIS)

    Lei, Jiawei; Kumarasamy, Karthikeyan; Zingre, Kishor T.; Yang, Jinglei; Wan, Man Pun; Yang, En-Hua

    2017-01-01

    Highlights: • Cool colored coating and PCM are two complementary passive cooling strategies. • A PCM cool colored coating system is developed. • The coating reduces cooling energy by 8.5% and is effective yearly in tropical Singapore. - Abstract: Cool colored coating and phase change materials (PCM) are two passive cooling strategies often used separately in many studies and applications. This paper investigated the integration of cool colored coating and PCM for building cooling through experimental and numerical studies. Results showed that cool colored coating and PCM are two complementary passive cooling strategies that could be used concurrently in tropical climate where cool colored coating in the form of paint serves as the “first protection” to reflect solar radiation and a thin layer of PCM forms the “second protection” to absorb the conductive heat that cannot be handled by cool paint. Unlike other climate zones where PCM is only seasonally effective and cool paint is only beneficial during summer, the application of the proposed PCM cool colored coating in building envelope could be effective throughout the entire year with a monthly cooling energy saving ranging from 5 to 12% due to the uniform climatic condition all year round in tropical Singapore.

  9. Legionella species colonization in cooling towers: risk factors and assessment of control measures.

    Science.gov (United States)

    Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2010-02-01

    Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and

  10. Thermoelectric self-cooling for power electronics: Increasing the cooling power

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Astrain, David; Aranguren, Patricia

    2016-01-01

    Thermoelectric self-cooling was firstly conceived to increase, without electricity consumption, the cooling power of passive cooling systems. This paper studies the combination of heat pipe exchangers and thermoelectric self-cooling, and demonstrates its applicability to the cooling of power electronics. Experimental tests indicate that source-to-ambient thermal resistance reduces by around 30% when thermoelectric self-cooling system is installed, compared to that of the heat pipe exchanger under natural convection. Neither additional electric power nor cooling fluids are required. This thermal resistance reaches 0.346 K/W for a heat flux of 24.1 kW/m"2, being one order of magnitude lower than that obtained in previous designs. In addition, the system adapts to the cooling demand, reducing this thermal resistance for increasing heat. Simulation tests have indicated that simple system modifications allow relevant improvements in the cooling power. Replacement of a thermoelectric module with a thermal bridge leads to 33.54 kW/m"2 of top cooling power. Likewise, thermoelectric modules with shorter legs and higher number of pairs lead to a top cooling power of 44.17 kW/m"2. These results demonstrate the applicability of thermoelectric self-cooling to power electronics. - Highlights: • Cooling power of passive systems increased. • No electric power consumption. • Applicable for the cooling of power electronics. • Up to 44.17 kW/m"2 of cooling power, one order of magnitude higher. • Source-to-ambient thermal resistance reduces by 30%.

  11. Thermo-economic Optimization of Solar Assisted Heating and Cooling (SAHC System

    Directory of Open Access Journals (Sweden)

    A. Ghafoor

    2014-12-01

    Full Text Available The energy demand for cooling is continuously increasing due to growing thermal loads, changing architectural modes of building, and especially due to occupants indoor comfort requirements resulting higher electricity demand notably during peak load hours. This increasing electricity demand is resulting higher primary energy consumption and emission of green house gases (GHG due to electricity generation from fossil fuels. An exciting alternative to reduce the peak electricity consumption is the possible utilization of solar heat to run thermally driven cooling machines instead of vapor compression machines utilizing high amount of electricity. In order to widen the use of solar collectors, they should also be used to contribute for sanitary hot water production and space heating. Pakistan lying on solar belt has a huge potential to utilize solar thermal heat for heating and cooling requirement because cooling is dominant throughout the year and the enormous amount of radiation availability provides an opportunity to use it for solar thermal driven cooling systems. The sensitivity analysis of solar assisted heating and cooling system has been carried out under climatic conditions of Faisalabad (Pakistan and its economic feasibility has been calculated using maximization of NPV. Both storage size and collector area has been optimized using different economic boundary conditions. Results show that optimum area of collector lies between 0.26m2 to 0.36m2 of collector area per m2 of conditioned area for ieff values of 4.5% to 0.5%. The optimum area of collector increases by decreasing effective interest rate resulting higher solar fraction. The NPV was found to be negative for all ieff values which shows that some incentives/subsidies are needed to be provided to make the system cost beneficial. Results also show that solar fraction space heating varies between 87 and 100% during heating season and solar fraction cooling between 55 and 100% during

  12. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-12-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof-mounted photovoltaic modules. The modules are fixed on special cradles which fold at night to expose the roof to the night sky, thereby enhancing night-time cooling, which is substantial in the desert environment. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. Application to a typical Middle-Eastern desert site reveals that indeed such a design is feasible with present-day technology; and should be even more attractive with future advances in technology. © 2011 Copyright Taylor and Francis Group, LLC.

  13. Carmes Polytechnique, Housing in the Heart of Paris Energy renovation of a social housing estate in Paris

    Directory of Open Access Journals (Sweden)

    Christian Horn

    2017-12-01

    Full Text Available The architecture offices Atelier de la Seine and Rethink have been commissioned with the engineers Pouget Consultants by the social landlord Paris Habitat for the extensive renovation of a social housing estate in the historic centre of Paris. The estate has been built in 1930 and integrates a part of the former college of the Lombard build in the 17th century. It belongs to the social housing typology 'Habitations à Bon Marché (HBM' constructed between1894 and 1949. This typology is generally characterized by its integration in its urban context and an apparent brick facade. The renovation project includes a focus on the reduction of the energy consumption. An important subject, as of the total number of 4.6 millions of social housing in France more than 50 % have been build before 1975 (before the first thermal regulation and many are still considered energy-intensive.

  14. Cyclotron resonance cooling by strong laser field

    International Nuclear Information System (INIS)

    Tagcuhi, Toshihiro; Mima, Kunioka

    1995-01-01

    Reduction of energy spread of electron beam is very important to increase a total output radiation power in free electron lasers. Although several cooling systems of particle beams such as a stochastic cooling are successfully operated in the accelerator physics, these cooling mechanisms are very slow and they are only applicable to high energy charged particle beams of ring accelerators. We propose here a new concept of laser cooling system by means of cyclotron resonance. Electrons being in cyclotron motion under a strong magnetic field can resonate with circular polarized electromagnetic field, and the resonance take place selectively depending on the velocity of the electrons. If cyclotron frequency of electrons is equal to the frequency of the electromagnetic field, they absorb the electromagnetic field energy strongly, but the other electrons remain unchanged. The absorbed energy will be converted to transverse kinetic energy, and the energy will be dumped into the radiation energy through bremastrahlung. To build a cooling system, we must use two laser beams, where one of them is counter-propagating and the other is co-propagating with electron beam. When the frequency of the counter-propagating laser is tuned with the cyclotron frequency of fast electrons and the co-propagating laser is tuned with the cyclotron frequency of slow electrons, the energy of two groups will approach and the cooling will be achieved. We solve relativistic motions of electrons with relativistic radiation dumping force, and estimate the cooling rate of this mechanism. We will report optimum parameters for the electron beam cooling system for free electron lasers

  15. 24 CFR 982.617 - Shared housing: Rent and voucher housing assistance payment.

    Science.gov (United States)

    2010-04-01

    ... Special Housing Types Shared Housing § 982.617 Shared housing: Rent and voucher housing assistance payment... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Shared housing: Rent and voucher housing assistance payment. 982.617 Section 982.617 Housing and Urban Development Regulations Relating to...

  16. Assisted Housing - Public Housing Authorities - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — Public Housing was established to provide decent and safe rental housing for eligible low-income families, the elderly, and persons with disabilities. Public housing...

  17. Use of cooling tower blow down in ethanol fermentation.

    Science.gov (United States)

    Rajagopalan, N; Singh, V; Panno, B; Wilcoxon, M

    2010-01-01

    Reducing water consumption in bioethanol production conserves an increasingly scarce natural resource, lowers production costs, and minimizes effluent management issues. The suitability of cooling tower blow down water for reuse in fermentation was investigated as a means to lower water consumption. Extensive chemical characterization of the blow down water revealed low concentrations of toxic elements and total dissolved solids. Fermentation carried out with cooling tower blow down water resulted in similar levels of ethanol and residual glucose as a control study using deionized water. The study noted good tolerance by yeast to the specific scale and corrosion inhibitors found in the cooling tower blow down water. This research indicates that, under appropriate conditions, reuse of blow down water from cooling towers in fermentation is feasible.

  18. The relationship between house size and life cycle energy demand: Implications for energy efficiency regulations for buildings

    International Nuclear Information System (INIS)

    Stephan, André; Crawford, Robert H.

    2016-01-01

    House size has significantly increased over the recent decades in many countries. Larger houses often have a higher life cycle energy demand due to their increased use of materials and larger area to heat, cool and light. Yet, most energy efficiency regulations for buildings fail to adequately include requirements for addressing the energy demand associated with house size. This study quantifies the effect of house size on life cycle energy demand in order to inform future regulations. It uses a parametric model of a typical detached house in Melbourne, Australia and varies its floor area from 100 to 392 m"2 for four different household sizes. Both initial and recurrent embodied energy requirements are quantified using input-output-based hybrid analysis and operational energy is calculated in primary energy terms over 50 years. Results show that the life cycle energy demand increases at a slower rate compared to house size. Expressing energy efficiency per m"2 therefore favours large houses while these require more energy. Also, embodied energy represents 26–50% across all variations. Building energy efficiency regulations should incorporate embodied energy, correct energy intensity thresholds for house size and use multiple functional units to measure efficiency. These measures may help achieve greater net energy reductions. - Highlights: • The life cycle energy demand (LCE) is calculated for 90 house sizes and 4 household sizes. • The LCE is sublinearly correlated with house size. • Larger houses appear to be more energy efficient per m"2 while they use more energy overall. • Embodied energy (EE) represents up to 52% of the LCE over 50 years. • Building energy efficiency regulations need to consider house size and EE.

  19. Housing choice and control, housing quality, and control over professional support as contributors to the subjective quality of life and community adaptation of people with severe mental illness.

    Science.gov (United States)

    Nelson, Geoffrey; Sylvestre, John; Aubry, Tim; George, Lindsey; Trainor, John

    2007-03-01

    This research examined two premises of supported housing: (a) that consumer choice/control over housing and support and the quality of housing are important contributors to the subjective quality of life and adaptation to community living of people with mental illness, and (b) that apartments provide mental health consumers with more choice/control over housing and support than group living arrangements. To test these two hypotheses, we collected data from participants with mental illness housed through a government initiative in Ontario, Canada. A total of 130 participants completed a baseline interview, and 91 of those participants also completed a follow-up interview 9-months later. Support was found for both hypotheses. The results were discussed in terms of the paradigm of supported housing, previous research, and implications for housing policy and program development in the community mental health sector.

  20. The Impact of Housing in Paediatrics Burns Cases: A Review of ...

    African Journals Online (AJOL)

    Objective: To determine the impact of housing on paediatric Burns Cases in Lagos Design: Prospective Study Subject: 40 children aged 10 days to 10 years admitted for Management after sustaining burns. Main Outcome Measurements: Housing plays a significant role in paediatric Burns Cases. Results: 70% of a total of ...

  1. Housing culture

    DEFF Research Database (Denmark)

    Roesdahl, Else; Scholkmann, Barbara

    2007-01-01

    On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies.......On houses and their furniture and fittings, and on the study of this - with a comparison of rural, urban, monastic and aristocratic housing, and a special section on heating technologies....

  2. Determination of radon in the air of housings of the Aguascalientes municipality

    International Nuclear Information System (INIS)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E.; Sanchez H, L.

    2006-01-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m 3 suggested by the EPA. (Author)

  3. Total Productive Maintenance at Paccar INC

    Directory of Open Access Journals (Sweden)

    Ştefan Farkas

    2010-06-01

    Full Text Available This paper reports the application of total productive maintenance method at Paccar Inc. truck’s plant in Victoria, Australia. The total productive maintenance method and total productive maintenance house are presented. The global equipment effectiveness is computed and exemplified. The production structure and organising maintenance are presented. Resultas of the variation of global equipment effectiveness and autonomous maintenance in a two weeks period of time are reported.

  4. Reports on 1979 result of Sunshine Project. R and D on solar cooling/heating and hot-water supply system (R and D on system for newly built private housing); 1979 nendo taiyo reidanbo oyobi kyuto system no kenkyu kaihatsu seika hokokusho. Shinchiku kojin jutakuyo system no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1980-03-01

    This report is for the results of fiscal 1979 on a solar cooling/heating and hot-water supply system for newly-built private housing. The research reports for fiscal 1974 to 1978 are as reported so far; for example, the research on energy-saving construction including thermal insulation method was used in an experimental housing completed in fiscal 1976. The solar heat collecting device was built in the experimental housing by increasing the scale of and utilizing the heat collecting device of a vacuum glass tube type on which research was done before fiscal 1975. The absorption refrigerating machine incorporated in the housing was of a forced circulation type which was high in temperature stability using the result of the research carried out until then. In fiscal 1979, as in fiscal 1978, one year residential experiment was conducted in which a family of a couple and two children lived in a house under an improved system as a result of a system variation and the like, and made an evaluation on the performance. Simultaneously, a control management system was developed in which a micro-computer was introduced for the purpose of improving the system performance, with the operation carried out under the micro-computer control. In addition, a fundamental experiment was also completed concerning a long-term heat accumulation by underground heat reserve. (NEDO)

  5. Estimation of European Union residential sector space cooling potential

    International Nuclear Information System (INIS)

    Jakubcionis, Mindaugas; Carlsson, Johan

    2017-01-01

    Data on European residential space cooling demands are scarce and often of poor quality. This can be concluded from a review of the Comprehensive Assessments on the energy efficiency potential in the heating and cooling sector performed by European Union Member States under Art. 14 of the Energy Efficiency Directive. This article estimates the potential space cooling demands in the residential sector of the EU and the resulting impact on electricity generation and supply systems using the United States as a proxy. A georeferenced approach was used to establish the potential residential space cooling demand in NUTS-3 regions of EU. The total potential space cooling demand of the EU was estimated to be 292 TW h for the residential sector in an average year. The additional electrical capacity needed was estimated to 79 GW. With proper energy system development strategies, e.g. matching capacity of solar PV with cooling demand, or introduction of district cooling, the stresses on electricity system from increasing cooling demand can be mitigated. The estimated potential of space cooling demand, identified in this paper for all EU Members States, could be used while preparing the next iteration of EU MS Comprehensive Assessments or other energy related studies. - Highlights: • An estimation of EU space cooling demand potential in residential sector is presented. • An estimate of space cooling demand potential is based on using USA data as a proxy. • Significant cooling demand increase can be expected. • Cooling demand increase would lead to increased stress in energy supply systems. • Proper policies and strategies might measurably decrease the impact on energy systems.

  6. 24 CFR 982.606 - Congregate housing: Who may reside in congregate housing.

    Science.gov (United States)

    2010-04-01

    ... Special Housing Types Congregate Housing § 982.606 Congregate housing: Who may reside in congregate housing. (a) An elderly person or a person with disabilities may reside in a congregate housing unit. (b... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Congregate housing: Who may reside...

  7. On the suitability of Peltier cooled Si-PIN detectors in transmission experiments

    International Nuclear Information System (INIS)

    Murty, V.R.K.; Devan, K.R.S.

    2001-01-01

    The performance of a Peltier cooled Si-PIN detector is compared with that for a Freolectric cooled Si(Li) detector, references being made to transmission experiments that evaluate total cross sections at low photon energies. The results of these measurements are discussed. (author)

  8. Cash-Cow into the Purse of Malaysian Property Investors: Students Housing Investment

    Directory of Open Access Journals (Sweden)

    Zubairu Abubakar Ghani

    2017-08-01

    Full Text Available Growing demand for higher education (HE and increasing students enrolment in higher education institutions (HEI has been a global issue especially in the last three decades and housing the growing student population has become a dilemma for all concern HEIs stakeholders. Globally increasing demand for HE and enrolment has long been not corresponding with student housing supply. Most HEIs provide housing accommodation for a small proportion of their total students’ population while the majority depend on private rental sector for their alternative housing. In most of the HEIs neighbouring community residential houses were rented out to students. These houses are not sufficient to accommodate the teaming student population because the market is dominated by traditional small-scale private developers. However, with the continuing expansion and demand for HE, increasing enrolment and increasing students housing demand, the study highlighted and suggested for private investors to pull up and dig into student housing investment. This will ameliorate and fill the shortfall created by inadequacy of HEIs housing provision. Student housing investment is a resilient market, lucrative venture and guaranteed cash cow.

  9. Mass Housing and Changings in Housing Demand, Case of Diyarbakir, Turkey

    OpenAIRE

    M. Oguz Sinemillioglu; Can Tuncay Akın; Havva Özyılmaz

    2005-01-01

    The aim of this study is to analyze changings in housing demand, especially in term of house size in Diyarbakır case, in Turkey. Though Housing in Turkey is in a free market system, there is a Mass Housing Administration (TOKÃ ) has been doing mass houses for, relatively, middle class income people. Diyarbakır, one of the cities that TOKÃ has done two thousand houses, has taken too much migration, so that the demand in housing form and structure has different alterations. This process should ...

  10. CDBG Housing Activity

    Data.gov (United States)

    Department of Housing and Urban Development — CDBG activity related to housing, including multifamily rehab, housing services, code enforcement, operation and repair of foreclosed property and public housing...

  11. Assessment of housing design decisions in informal housing ...

    African Journals Online (AJOL)

    The rapid urbanisation of cities in developing countries has witnessed a growth in the volume of housing construction in the urban areas. The demand for housing and the inability of government to meet this demand has encouraged the growth of informal housing. The concept of healthy buildings is of great importance, ...

  12. Study on climate control of dwellings using underground air tunnel in the cold region. Part 1. Cooling performance of the underground air tunnel connected to a small-scaled test house; Kanreichi ni okeru chika air tunnel ni yoru junetsukankyo kaizen ni kansuru kenkyu. 1. Shokibo shiken kaoku ni okeru kaki no ryobo seino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Miki, Y; Sanji, H; Ito, J; Komoda, T; Mitsuoka, K; Mogami, S [Kitami Institute of Technology, Hokkaido (Japan)

    1997-11-25

    Underground air tunnel is provided for cooling an experimentally built small house and the cooling performance is examined at Kitami Institute of Technology, Hokkaido. The house is provided with 120mm-thick layers of insulating material under the floor and inside the side walls and partitioning walls. The windows are equipped with blinds, with reed screens positioned outside to cover the windows. The air tunnel is a hard vinyl chloride tube, 200mm in internal diameter. It is buried 4.5m deep in the ground, and extends as long as 27m. A filter-provided 72W blower installed at the tunnel outlet is driven to force air through. As for the natural soil temperature in summer, it is found variable between 7.2 and 8.5degC. As the result of the experiment, it is found that thanks to the underground tunnel the room temperature is kept below 27degC even when the maximum temperature in the daytime is 30degC or higher provided the air flow is appropriately regulated. In this experiment, the maximum rate of instantaneously removed heat is approximately 2.5 times higher than the values in other previously reported experiments. The daily coefficient of performance is 6.5-11.1, again higher than the previously reported values. Different from application in warm regions, the effect of rise in the surrounding soil temperature on the cooling performance is not so conspicuous. 3 refs., 12 figs., 1 tab.

  13. Assessing the Cooling Benefits of Tree Shade by an Outdoor Urban Physical Scale Model at Tempe, AZ

    Directory of Open Access Journals (Sweden)

    Qunshan Zhao

    2018-01-01

    Full Text Available Urban green infrastructure, especially shade trees, offers benefits to the urban residential environment by mitigating direct incoming solar radiation on building facades, particularly in hot settings. Understanding the impact of different tree locations and arrangements around residential properties has the potential to maximize cooling and can ultimately guide urban planners, designers, and homeowners on how to create the most sustainable urban environment. This research measures the cooling effect of tree shade on building facades through an outdoor urban physical scale model. The physical scale model is a simulated neighborhood consisting of an array of concrete cubes to represent houses with identical artificial trees. We tested and compared 10 different tree densities, locations, and arrangement scenarios in the physical scale model. The experimental results show that a single tree located at the southeast of the building can provide up to 2.3 °C hourly cooling benefits to east facade of the building. A two-tree cluster arrangement provides more cooling benefits (up to 6.6 °C hourly cooling benefits to the central facade when trees are located near the south and southeast sides of the building. The research results confirm the cooling benefits of tree shade and the importance of wisely designing tree locations and arrangements in the built environment.

  14. Optimized design of an ex-vessel cooling thermosyphon for decay heat removal in SFR

    International Nuclear Information System (INIS)

    Choi, Jae Young; Jeong, Yong Hoon; Song, Sub Lee; Chang, Soon Heung

    2017-01-01

    Passive decay heat removal and sodium fire are two major key issues of nuclear safety in sodium-cooled fast reactor (SFR). Several decay heat removal systems (DHR) were suggested for SFR around the world so far. Those DHRS mainly classified into two concepts: Direct reactor cooling system and ex-vessel cooling system. Direct reactor cooling method represented by PDHRS from PGSFR has disadvantages on its additional in-vessel structure and potential sodium fire risk due to the sodium-filled heat exchanger exposed to air. Contrastively, ex-vessel cooling method represented by RVACS from PRISM has low decay heat removal performance, which cannot be applicable to large scale reactors, generally over 1000 MWth. No passive DHRSs which can solve both side of disadvantages has been suggested yet. The goal of this study was to propose ex-vessel cooling system using two-phase closed thermosyphon to compensate the disadvantages of the past DHRSs. Reference reactor was Innovative SFR (iSFR), a pool-type SFR designed by KAIST and featured by extended core lifetime and increased thermal efficiency. Proposed ex-vessel cooling system consisted of 4 trains of thermosyphons and designed to remove 1% of thermal power with 10% of margin. The scopes of this study were design of proposed passive DHRS, validation of system analysis and optimization of system design. Mercury was selected as working fluid to design ex-vessel thermosyphon in consideration of system geometry, operating temperature and required heat flux. SUS 316 with chrome coated liner was selected as case material to resist against high corrosivity of mercury. Thermosyphon evaporator was covered on the surface of reactor vessel as the geometry of hollow shell filled with mercury. Condenser was consisted of finned tube bundles and was located in isolated water pool, the ultimate heat sink. Operation limits and thermal resistance was estimated to guarantee whether the design was adequate. System analysis was conducted by in-house

  15. Situation-Based Housing

    DEFF Research Database (Denmark)

    Duelund Mortensen, Peder

    2011-01-01

    Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen......Presentation of urban housing research on flexible housing types in the Copenhagen Region: Theoretical background, methodology, analyse of spatial organization, interviews and results. Cases: Pærehaven in Ølby, Køge and M-house in Ørestad, Copenhagen...

  16. 24 CFR 8.25 - Public housing and multi-family Indian housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Public housing and multi-family Indian housing. 8.25 Section 8.25 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development NONDISCRIMINATION BASED ON HANDICAP IN FEDERALLY ASSISTED PROGRAMS AND...

  17. Air conditioning total system for a coffee house. Groundwater as a supplier for heat and coldness; Klimatechnisches Gesamtsystem fuer ein Cafe. Grundwasser als Waerme- und Kaelte-Lieferant

    Energy Technology Data Exchange (ETDEWEB)

    Platzer, Gerald [Daikin Airconditioning Germany GmbH, Stutensee (Germany)

    2010-07-01

    The new building of a coffee-house of the land baker's shop Ihle on the outskirts of Augsburg (Federal Republic of Germany) was not only a new way of the baker's shop in the catering trade, but also in the conception of the building and its technical equipment. The linkage of heating, climate, ventilation and commercial refrigeration systems to a highly efficient total system succeeded in outstanding way.

  18. Roof top extensions for multifamily houses in Slovakia

    Science.gov (United States)

    Szekeres, K.

    2010-12-01

    In the countries of the European Union with the exception of Malta, approximately 100.1 million multifamily dwelling units are situated. These dwellings count for an average of 47.5% of the total housing stock in European Union countries. At present in Slovakia and also other countries of Central and Eastern Europe, there are vast housing areas which were built after World War II. Slovakia's multifamily housing stock was privatized during the 1990s. Considering that the economy of Slovakia is not capable of replacing the existing housing fund, which is located in the multifamily houses that were built after World War II, it is necessary to place an increased emphasis on the renovation of this housing fund. The expenditures for the refurbishment of multifamily housing stock in recent decades, when compared with the demand, have been at a very low level. The main problems involving the current multifamily housing stock in Slovakia are: the need for modernization, the low level of energy efficiency, and the insufficient level of building maintenance. One of the options for creating sufficient sources for the renovation of apartment buildings is to utilize the roofs of apartment buildings as construction areas for building additional floors (over - roofing). The means acquired from the sale of the new floors after deducting the costs can be used for renovation. It is a matter of a one-time possibility, which is limited by many factors that depend on the localization and constructive technical solutions for apartment buildings. This article is an outcome of the SuReFit "Sustainable Roof Extension Retrofit for High-Rise Social Housing in Europe" international research project.

  19. Effects of evaporative cooling on reproductive performance and milk production of dairy cows in hot wet conditions

    Science.gov (United States)

    Khongdee, S.; Chaiyabutr, N.; Hinch, G.; Markvichitr, K.; Vajrabukka, C.

    2006-05-01

    Fourteen animals of second and third lactation of Thai Friesian crossbred cows (87.5% Friesian × 12.5% Bos indicus) located at Sakol Nakhon Research and Breeding Centre, Department of Livestock Development, Ministry of Agriculture and Cooperatives, were divided randomly into two groups of seven each to evaluate the effects of evaporative cooling on reproductive and physiological traits under hot, humid conditions. Results indicated that installation of evaporating cooling in the open shed gave a further improvement in ameliorating heat stress in dairy cows in hot-wet environments by utilising the low humidity conditions that naturally occur during the day. The cows housed in an evaporatively cooled environment had both a rectal temperature and respiration rate (39.09°C, 61.39 breaths/min, respectively) significantly lower than that of the non-cooled cows (41.21°C; 86.87 breaths/min). The former group also had higher milk yield and more efficient reproductive performance (pregnancy rate and reduced days open) than the latter group. It is suggested that the non-evaporatively cooled cows did not gain benefit from the naturally lower heat stress during night time.

  20. Sustained housing-type social buffering following social housing in male rats.

    Science.gov (United States)

    Kiyokawa, Yasushi; Ishida, Aya; Takeuchi, Yukari; Mori, Yuji

    2016-05-01

    In social animals, recovery from the adverse effects of distressing stimuli is promoted by subsequent cohousing with a conspecific animal(s). This phenomenon has been termed housing-type social buffering. We previously found that social housing induced housing-type social buffering in fear-conditioned male rats. This buffering took the form of attenuated conditioned hyperthermia in response to an auditory conditioned stimulus (CS). Here, we assessed whether this social buffering is sustained even if the subject is housed alone after a period of social housing. When fear-conditioned subjects were housed alone during a 48-h period between conditioning and re-exposure to the auditory CS, they exhibited conditioned hyperthermia in response to the CS. However, conditioned hyperthermia was not observed when the 12-h period of social housing began 24 and 36h after conditioning during the 48-h period. This was not the case when the 12-h period of social housing began 0 and 12h after the conditioning. These results suggest that housing-type social buffering is sustained for 12h after the 12-h period of social housing. We next considered whether increasing the duration of social housing would extend the period of social buffering. We observed social buffering of conditioned hyperthermia 24 and 48, but not 96h after a 24-h period of social housing. These results suggest that social buffering was extended when the duration of social housing was increased. Taken together, our findings indicate that housing-type social buffering is sustained after a period of social housing. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Active house concept versus passive House

    NARCIS (Netherlands)

    Zeiler, W.; Boxem, G.; Vehler, R.; Verhoeven, M.; Fremouw, M.

    2009-01-01

    The passive house concept is the present trend in energy efficient sustainable dwellings. Within the passive house concept every effort is made to minimize the energy use. Substantial savings can be achieved by passive energy systems, especially natural ventilation, summer shading and winter solar

  2. Thermal performance of 2350 kW totally enclosed air to air cooled motor

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.C.; Kuo, S.C.; Chen, S.L. [National Taiwan Univ., Taipei, Taiwan (China). Dept. of Mechanical Engineering; Cheng, T.F. [TATUNG CO., Sanhsia, Taiwan (China)

    2009-07-01

    This study investigated numerically and experimentally the thermal performance of a 2350 kW enclosed air-to-air cooled motor. The experiment was divided into 2 sections. The centrifugal fans were tested using a standard test apparatus. Flow rates, output power, and pressure drop between the inlet and outlet were obtained. The motor was then tested to measure the flow rate of the external flow, and inlet and outlet temperatures of the external and internal flow in the heat exchanger. Motor performance was then simulated using a computational fluid dynamics (CFD) tool. Heat transfer within the motor was divided into external and internal flows. External flow was driven by the rotation of the centrifugal fan mounted to the frame on the motor shaft and passing through the tubes of a staggered heat exchanger mounted on the top of the frame. Internal flow was circulated through the heat exchanger by 2 axial fans located on either side of the rotor and cooled by the external flow. Axial and centrifugal fan simulations were in good agreement with results obtained during the experiments. The study demonstrated that the calculated velocity distributions of external flow fluids through the heat exchanger tubes are non-uniform. Air outlet temperatures for internal and external flows were estimated within 2 per cent. However, stator and rotor simulations were 3 per cent lower than experimental measured values. 7 refs., 1 tab., 15 figs.

  3. Assessment of total efficiency in adiabatic engines

    Science.gov (United States)

    Mitianiec, W.

    2016-09-01

    The paper presents influence of ceramic coating in all surfaces of the combustion chamber of SI four-stroke engine on working parameters mainly on heat balance and total efficiency. Three cases of engine were considered: standard without ceramic coating, fully adiabatic combustion chamber and engine with different thickness of ceramic coating. Consideration of adiabatic or semi-adiabatic engine was connected with mathematical modelling of heat transfer from the cylinder gas to the cooling medium. This model takes into account changeable convection coefficient based on the experimental formulas of Woschni, heat conductivity of multi-layer walls and also small effect of radiation in SI engines. The simulation model was elaborated with full heat transfer to the cooling medium and unsteady gas flow in the engine intake and exhaust systems. The computer program taking into account 0D model of engine processes in the cylinder and 1D model of gas flow was elaborated for determination of many basic engine thermodynamic parameters for Suzuki DR-Z400S 400 cc SI engine. The paper presents calculation results of influence of the ceramic coating thickness on indicated pressure, specific fuel consumption, cooling and exhaust heat losses. Next it were presented comparisons of effective power, heat losses in the cooling and exhaust systems, total efficiency in function of engine rotational speed and also comparison of temperature inside the cylinder for standard, semi-adiabatic and full adiabatic engine. On the basis of the achieved results it was found higher total efficiency of adiabatic engines at 2500 rpm from 27% for standard engine to 37% for full adiabatic engine.

  4. Solar heating and cooling system installed at Leavenworth, Kansas

    Science.gov (United States)

    1980-01-01

    A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

  5. Genotype by housing interaction for conformation and workability traits in Danish Holsteins

    DEFF Research Database (Denmark)

    Lassen, J.; Mark, Thomas

    2008-01-01

    A total of 30,190 first-parity Danish Holstein cows housed in free stalls or tie stalls were analyzed to quantify to what degree genotype by housing interaction existed for 21 conformation and 2 workability traits. Each trait measured in different housing systems was treated as 2 separate traits...... in a bivariate animal model. Genetic correlations between the 2 traits as well as differences in genetic and residual variance were used as measurements of whether or not genotype by housing interaction occurred. Genetic correlations were in general close to unity (>0.9), except for body width (0.87 +/- 0...

  6. A very cool cooling system

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The NA62 Gigatracker is a jewel of technology: its sensor, which delivers the time of the crossing particles with a precision of less than 200 picoseconds (better than similar LHC detectors), has a cooling system that might become the precursor to a completely new detector technique.   The 115 metre long vacuum tank of the NA62 experiment. The NA62 Gigatracker (GTK) is composed of a set of three innovative silicon pixel detectors, whose job is to measure the arrival time and the position of the incoming beam particles. Installed in the heart of the NA62 detector, the silicon sensors are cooled down (to about -20 degrees Celsius) by a microfluidic silicon device. “The cooling system is needed to remove the heat produced by the readout chips the silicon sensor is bonded to,” explains Alessandro Mapelli, microsystems engineer working in the Physics department. “For the NA62 Gigatracker we have designed a cooling plate on top of which both the silicon sensor and the...

  7. Energy consumption of building related energy functions in houses and utility buildings

    International Nuclear Information System (INIS)

    Van Arkel, W.G.; Jeeninga, H.; Menkveld, M.; Ruijg, G.J.

    1999-11-01

    This study investigates the development of the use of electricity and natural gas in houses and buildings until 2010. For the domestic sector it is studied how much energy is used now and will be used in future for heating, for production of hot water, for lighting, for ventilation and for cooling. For different sorts of buildings (shops, hospitals, schools, offices, restaurants) it has been determined how much gas will be used for heating, for hot water production and by humidifiers. It has also been calculated how much electricity will be used for lighting, ventilation, cooling and humidifying. The influence of higher and lower energy prices on the amount of use has been studied. Experts have been asked to give their opinions on trends in the use of buildings and the role of new technologies. The influence of these ideas on the use of energy has been calculated. 44 refs

  8. Experimental Study on Solar Cooling Tube Using Thermal/Vacuum Emptying Method

    Directory of Open Access Journals (Sweden)

    Huizhong Zhao

    2012-01-01

    Full Text Available A solar cooling tube using thermal/vacuum emptying method was experimentally studied in this paper. The coefficient of performance (COP of the solar cooling tube was mostly affected by the vacuum degree of the system. In past research, the thermal vacuum method, using an electric oven and iodine-tungsten lamp to heat up the adsorbent bed and H2O vapor to expel the air from the solar cooling tube, was used to manufacture solar cooling tubes. This paper presents a novel thermal vacuum combined with vacuum pump method allowing an increased vacuum state for producing solar cooling tubes. The following conclusions are reached: the adsorbent bed temperature of solar cooling tube could reaches up to 233°C, and this temperature is sufficient to meet desorption demand; the refrigerator power of a single solar cooling tube varies from 1 W to 12 W; the total supply refrigerating capacity is about 287 kJ; and the COP of this solar cooling tube is about 0.215.

  9. Ammonia emission from aviary housing systems for laying hens : inventory, characteristics and solutions

    NARCIS (Netherlands)

    Groot Koerkamp, P.W.G.

    1998-01-01

    The development and practical application of welfare friendly aviary housing systems for laying hens, that generally emit more ammonia per hen than battery cage housing systems, would conflict with the Dutch policy to substantially reduce the total emission of ammonia from animal

  10. Air and water qualities around small ruminant houses in Central Java - Indonesia

    NARCIS (Netherlands)

    Budisatria, I.G.S.; Udo, H.M.J.; Zijpp, van der A.J.; Murti, T.W.; Baliarti, E.

    2007-01-01

    There is a general concern that livestock can have a profound effect on the environment, also in smallholder production systems. This paper presented the impact of small ruminants on the quality of air and water in and around small ruminant houses. In total, 27 small ruminant houses from the three

  11. Membrane distillation of industrial cooling tower blowdown water

    Directory of Open Access Journals (Sweden)

    N.E. Koeman-Stein

    2016-06-01

    Full Text Available The potential of membrane distillation for desalination of cooling tower blowdown water (CTBD is investigated. Technical feasibility is tested on laboratory and pilot scale using real cooling tower blowdown water from Dow Benelux in Terneuzen (Netherlands. Two types of membranes, polytetrafluorethylene and polyethylene showed good performance regarding distillate quality and fouling behavior. Concentrating CTBD by a factor 4.5 while maintaining a flux of around 2 l/m2*h was possible with a water recovery of 78% available for reuse. Higher concentration factors lead to severe decrease in flux which was caused by scaling. Membrane distillation could use the thermal energy that would otherwise be discharged of in a cooling tower and function as a heat exchanger. This reduces the need for cooling capacity and could lead to a total reduction of 37% water intake for make-up water, as well as reduced energy and chemicals demands and greenhouse gas emissions.

  12. NPR and ANSI Containment Study Using Passive Cooling Techniques

    International Nuclear Information System (INIS)

    Shin, J. J.; Iotti, R. C.; Wright, R. F.

    1993-01-01

    Passive containment cooling study of NPR (New Production Reactor) and ANSI (Advanced Neutron Source) following postulated loss of coolant accident with a coincident station blackout due to total loss of all alternating current power are studied analytically and experimentally. All the reactor and containment cooling under this condition would rely on the passive cooling system which removes reactor decay heat and provides emergency core and containment cooling. Containment passive emergency core and containment cooling. Containment passive cooling for this study takes place in the annulus between containment steel shell and concrete shield building by natural convection air flow and concrete shield building by natural convection air flow and thermal radiation. Various heat transfer coefficients inside annular air space were investigated by running the modified Contempt code Contempt-Npr. In order to verify proper heat transfer coefficient, temperature, heat flux and velocity profiles were measured inside annular air space of the test facility which is a 24 foot (7.3m) high, steam heated inner cylinder of three foot (.91m) diameter and five and halt foot (1.7m) diameter outer cylinder. Comparison of Contempt-Npr and WGOTHIC was done for reduced scale Npr. It is concluded that Npr and ANSI containments can be passively cooled with air alone without extended cooling surfaces or passive water spray

  13. Housing system and laying hen strain impacts on egg microbiology.

    Science.gov (United States)

    Jones, D R; Anderson, K E

    2013-08-01

    Alternative hen housing is becoming more commonplace in the egg market. However, a complete understanding of the implications for alternative housing systems on egg safety has not been achieved. The current study examines the impact of housing Hy-Line Brown, Hy-Line Silver Brown, and Barred Plymouth Rock hens in conventional cage, cage-free, and free range egg production systems on shell microbiology. Eggs were collected at 4 sampling periods. Egg shell emulsion pools were formed and enumerated for total aerobic organisms, Enterobacteriaceae, and yeast and mold counts. Hy-Line Brown and Hy-Line Silver Brown hens produced eggs with significantly (P Eggs from conventional cages had significantly different (P eggs with significantly different (P eggs having the lowest level of contamination for the hen strains. There were no differences within each strain among housing systems for yeast and mold contamination. The study shows that hen strain has an effect on egg microbial levels for various housing systems, and egg safety should be considered when making hen strain selections for each housing system.

  14. Development of a Measure of Housing and Housing Services.

    Science.gov (United States)

    Clark, Colleen; Young, M Scott; Teague, Gregory; Rynearson-Moody, Sarah

    2016-01-01

    The Housing Program Measure (HPM) was designed to document critical elements of a range of housing program types and associated services. Qualitative methods, including literature review and open-ended interviews, were used to determine pertinent HPM domains and to develop the pool of items. The measure was pre-tested, and reliability and validity analyses were applied to revise and strengthen the measure. The resulting measure furthers homelessness research by providing a tool that can be used to define housing and housing services interventions across diverse projects and disciplines, to facilitate program management by matching housing resources to the needs of homeless individuals, and to support model development by measuring progress to goals.

  15. 12 CFR 932.2 - Total capital requirement.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Total capital requirement. 932.2 Section 932.2 Banks and Banking FEDERAL HOUSING FINANCE BOARD FEDERAL HOME LOAN BANK RISK MANAGEMENT AND CAPITAL STANDARDS FEDERAL HOME LOAN BANK CAPITAL REQUIREMENTS § 932.2 Total capital requirement. (a) Each Bank shall...

  16. Reducing Urban Heat Island Effect with Thermal Comfort Housing and Honeycomb Townships

    DEFF Research Database (Denmark)

    Davis, Mohd. Peter; Reimann, Gregers Peter; Ghazali, Mazlin

    2005-01-01

    Putra Malaysia can achieve almost passive thermal comfort without air-conditioning, even on the hottest days of the year. ‘Honeycomb townships’, a recent architectural invention by one of the authors, is a new method of subdividing land which saves greatly on roads, thereby permitting larger gardens...... consequences of urbanisation and can be corrected in Malaysia and avoided by other developing countries with a sensible application of the technologies outlined in this paper which prevent the thermal mass of houses and roads from absorbing solar radiation. ‘Cool House’ technology, developed at Universiti...

  17. Irradiation control of pathogenic bacteria and their growth during storage time in cooled chicken

    International Nuclear Information System (INIS)

    Ha Yiming; Wang Feng; Fan Bei; Liu Shuliang; Ju Hua

    2009-01-01

    The growth of pathogenic bacteria during storage time and their D 10 values by irradiation in cooled chicken were evaluated. The total numbers of colony, E.coli 10003, Campylobacter jejuni33560 and CY04 of the D 10 values were 1.434 kGy, 0.408 kGy, 0.175 kGy, 0.2 kGy respectively in cooled chicken. The results show that total bacteria count in vacuum packaged cooled chicken sample is 5.66 lg(CFU/g) and 4.90 lg (CFU/g) after 3 kGy and 5 kGy irradiation. And in storage at 0∼4 degree C the storage shelf-life of irradiated vacuum packaged cooled chicken could extend to 21 d and 28 d. It can be deduced that pathogenic bacteria can be controlled effectively by irradiation. (authors)

  18. Magnetocaloric Effect and Thermoelectric Cooling - A Synergistic Cooling Technology

    Science.gov (United States)

    2018-01-16

    Thermoelectric Cooling - A Synergistic Cooling Technology Sb. GRANT NUMBER N00173-14-1-G016 Sc. PROGRAM ELEMENT NUMBER 82-2020-17 6. AUTHOR(S) 5d...Magnetocaloric Effect and Thermoelectric Cooling - A Synergistic Cooling Technology NRL Grant N00173-14-l-G016 CODE 8200: Spacecraft Engineering Department...82-11-0 1: Space and Space Systems Technology General Engineering & Research, L.L.C. Technical & Administrative point of contact: Dr. Robin

  19. WORKSHOP: Beam cooling

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Cooling - the control of unruly particles to provide well-behaved beams - has become a major new tool in accelerator physics. The main approaches of electron cooling pioneered by Gersh Budker at Novosibirsk and stochastic cooling by Simon van der Meer at CERN, are now complemented by additional ideas, such as laser cooling of ions and ionization cooling of muons

  20. Experimental Analysis of Variable Capacity Heat Pump Systems equipped with a liquid-cooled frequency inverter

    OpenAIRE

    Ebraheem, Thair

    2013-01-01

    Using an inverter-driven compressor in variable capacity heat pump systems has a main drawback, which is the extra loss in the inverter. The present experimental study aims to recover the inverter losses by using brine-cooled and water-cooled inverters, thereby improving the total efficiency of the heat pump system. In order to achieve this goal, a test rig with the air-cooled, water-cooled and brine-cooled inverters is designed and built, and a comparative analysis of the recovered heat, inv...

  1. Hybrid Geothermal Heat Pumps for Cooling Telecommunications Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Koenraad J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Zurmuhl, David P. [Cornell University; Lukawski, Maciej Z. [Cornell University; Aguirre, Gloria A. [Cornell University; Schnaars, George P. [Cornell University; Anderson, C. Lindsay [Cornell University; Tester, Jefferson W. [Cornell University

    2018-02-14

    The technical and economic performance of geothermal heat pump (GHP) systems supplying year-round cooling to representative small data centers with cooling loads less than 500 kWth were analyzed and compared to air-source heat pumps (ASHPs). A numerical model was developed in TRNSYS software to simulate the operation of air-source and geothermal heat pumps with and without supplementary air cooled heat exchangers - dry coolers (DCs). The model was validated using data measured at an experimental geothermal system installed in Ithaca, NY, USA. The coefficient of performance (COP) and cooling capacity of the GHPs were calculated over a 20-year lifetime and compared to the performance of ASHPs. The total cost of ownership (TCO) of each of the cooling systems was calculated to assess its economic performance. Both the length of the geothermal borehole heat exchangers (BHEs) and the dry cooler temperature set point were optimized to minimize the TCO of the geothermal systems. Lastly, a preliminary analysis of the performance of geothermal heat pumps for cooling dominated systems was performed for other locations including Dallas, TX, Sacramento, CA, and Minneapolis, MN.

  2. Cool? Young people investigate living in cold housing and fuel poverty. A mixed methods action research study

    Directory of Open Access Journals (Sweden)

    Kimberley C. O'Sullivan

    2017-12-01

    Conclusion: The integrated results confirm that cold housing and risk of fuel poverty are important problems for young people in New Zealand. Results contribute to the evidence-base for policy targeting of schemes such as the Government-sponsored retrofitting of insulation to households with dependent children.

  3. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Conlin, F. [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Podorson, D. [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Alaigh, K. [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Davis, T. [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2016-02-18

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

  4. Public Housing: A Tailored Approach to Energy Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J.; Conlin, F.; Podorson, D.; Alaigh, K.

    2014-06-01

    Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.

  5. Sydney Opera House Rise

    DEFF Research Database (Denmark)

    2013-01-01

    Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House".......Sydney Opera House Exhibition (2013) A CITA research and exhibition project, for Sydney Opera House exhibition "Danish Design at the House"....

  6. 120 Years of U.S. Residential Housing Stock and Floor Space

    Energy Technology Data Exchange (ETDEWEB)

    Pinto de Moura, Maria C.; Smith, Steven J.; Belzer, David B.

    2015-08-11

    Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions. Floor space is a major driver of building energy demand. This paper develops a historical time series of total residential floor space for 1891-2010 and examines the role of socio-economic drivers GDP, population and household size on floor space. Using primarily data from the U.S. Census Bureau, we develop new construction and vintage-disaggregated housing stock for three building types, and address various data inconsistency issues. An examination of the long-term relationship of GDP and total residential floor space shows a remarkably constant trend over the period. While population increases five times over the period, a 50% decrease in household size contributes towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. Total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years.

  7. Economic analysis of passive houses and low-energy houses compared with standard houses

    International Nuclear Information System (INIS)

    Audenaert, A.; Cleyn, S.H. de; Vankerckhove, B.

    2008-01-01

    As the energy demand used for space heating accounts for 78% of EU15 household delivered energy consumption, significant reductions in energy demand can be achieved by promoting low-energy buildings. Our study investigates three building types: the standard house, the low-energy house and the passive house. As more far-reaching measures concerning energy savings usually lead to higher investments, the aim of our study is to perform an economic analysis in order to determine the economic viability of the three building types

  8. Assisted Housing - Public Housing Developments - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The general location of an entire Public Housing Development. A distinct address is chosen to represent the general location of an entire Public Housing Development,...

  9. Life cycle carbon emissions inventory of brick masonry and light steel framing houses in Brasilia: proposal of design guidelines for low-carbon social housing

    Directory of Open Access Journals (Sweden)

    Lucas Rosse Caldas

    Full Text Available Abstract This study evaluated the CO2eq emissions during the life cycle of two social housing projects in the city of Brasilia. A house of ceramic brick masonry was compared to a light steel framing one. The life cycle carbon emissions assessment (LCCO2A with a cradle-to-grave approach was used. The relation between the thermal performance of the wall systems and CO2eq emissions in the operational phase of the houses were evaluated using the DesignBuilder software. In addition, six scenarios composed of three CO2eq emission factors from the Brazilian electrical grid and two schedules of occupation of houses (full and part time were evaluated. The brick masonry house presented less CO2eq emissions than the light steel framing one. For both houses, the operational phase was the most significant regarding the total CO2eq emissions (50% to 70%, followed by the construction (20% to 30%, maintenance (11% to 20% and end-of-life (lower than 1% phases. The results also showed the importance of considering different CO2eq emission factors for the Brazilian context in the operational phase. Finally, based on the results obtained, design guidelines for low carbon social housing were proposed.

  10. The impact of housing policies and housing markets on ethnic spatial segregation

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Andersson, Roger; Wessel, Terje

    2015-01-01

    This paper examines how ethnic segregation is connected to an ethnic division of the housing market and a spatial separation of different housing tenures in four Nordic cities. Explanations for the differences across the cities are found by comparing housing markets and housing policies....... The housing markets are in all four cities ethnically segmented with high concentrations of immigrants in some forms of tenures (especially social/public housing) and low concentrations in others. We further discuss the reasons for the observed pattern. The paper shows that the spatial distribution...... housing, while co-operative housing is crucial in the fourth. It is also shown that a policy of neighbourhood tenure mix in one of the cities has resulted in a relatively low degree of segregation in spite of high concentrations of immigrants in social/public housing....

  11. Numerical modelling of series-parallel cooling systems in power plant

    Directory of Open Access Journals (Sweden)

    Regucki Paweł

    2017-01-01

    Full Text Available The paper presents a mathematical model allowing one to study series-parallel hydraulic systems like, e.g., the cooling system of a power boiler's auxiliary devices or a closed cooling system including condensers and cooling towers. The analytical approach is based on a set of non-linear algebraic equations solved using numerical techniques. As a result of the iterative process, a set of volumetric flow rates of water through all the branches of the investigated hydraulic system is obtained. The calculations indicate the influence of changes in the pipeline's geometrical parameters on the total cooling water flow rate in the analysed installation. Such an approach makes it possible to analyse different variants of the modernization of the studied systems, as well as allowing for the indication of its critical elements. Basing on these results, an investor can choose the optimal variant of the reconstruction of the installation from the economic point of view. As examples of such a calculation, two hydraulic installations are described. One is a boiler auxiliary cooling installation including two screw ash coolers. The other is a closed cooling system consisting of cooling towers and condensers.

  12. Model-based energy monitoring and diagnosis of telecommunication cooling systems

    International Nuclear Information System (INIS)

    Sorrentino, Marco; Acconcia, Matteo; Panagrosso, Davide; Trifirò, Alena

    2016-01-01

    A methodology is proposed for on-line monitoring of cooling load supplied by Telecommunication (TLC) cooling systems. Sensible cooling load is estimated via a proportional integral controller-based input estimator, whereas a lumped parameters model was developed aiming at estimating air handling units (AHUs) latent heat load removal. The joint deployment of above estimators enables accurate prediction of total cooling load, as well as of related AHUs and free-coolers energy performance. The procedure was then proven effective when extended to cooling systems having a centralized chiller, through model-based estimation of a key performance metric, such as the energy efficiency ratio. The results and experimental validation presented throughout the paper confirm the suitability of the proposed procedure as a reliable and effective energy monitoring and diagnostic tool for TLC applications. Moreover, the proposed modeling approach, beyond its direct contribution towards smart use and conservation of energy, can be fruitfully deployed as a virtual sensor of removed heat load into a variety of residential and industrial applications. - Highlights: • Accurate cooling load prediction in telecommunication rooms. • Development of an input-estimator for sensible cooling load simulation. • Model-based estimation of latent cooling load. • Model-based prediction of centralized chiller energy performance in central offices. • Diagnosis-oriented application of proposed cooling load estimator.

  13. Optimization design of solar enhanced natural draft dry cooling tower

    International Nuclear Information System (INIS)

    Zou, Zheng; Guan, Zhiqiang; Gurgenci, Hal

    2013-01-01

    Highlights: • We proposed a cost model for solar enhanced natural draft dry cooling tower. • We proposed an optimization scheme for this new cooling system. • We optimally designed one for a 50 MW EGS geothermal plant as a demonstration. • Results proved its economic advantages for EGS geothermal application. - Abstract: This paper proposed an optimization scheme for solar enhanced natural draft dry cooling tower design, in which a detailed cost model was proposed including capital, labour, maintenance and operation costs of each component. Based on the developed cost model, the optimal design option can be identified in terms of the relatively lower annual cost and the relatively higher total extra income over the Solar Enhanced Natural Draft Dry Cooling Tower (SENDDCT) lifetime. As a case study, a SENDDCT was optimally designed to meet the cooling demand for a 50 MW geothermal power plant with Engineered Geothermal System (EGS) technology. The results showed that the optimized SENDDCT not only has better cooling performance during the daytime but also is a cost effective option for EGS geothermal power plants

  14. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  15. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  16. Cooling towers

    International Nuclear Information System (INIS)

    Boernke, F.

    1975-01-01

    The need for the use of cooling systems in power plant engineering is dealt with from the point of view of a non-polluting form of energy production. The various cooling system concepts up to the modern natural-draught cooling towers are illustrated by examples. (TK/AK) [de

  17. Modernization in the Manitoba north: The housing initiative

    International Nuclear Information System (INIS)

    Robson, R.

    1993-01-01

    Responding to the perceived community needs of the native population, the Canadian federal and provincial governments have implemented a series of programs intended to address the issues of community well-being, a central feature of which was the modernization of native communities. In Manitoba, the best examples of this modernization initiative are associated with the hydroelectric power projects in northern Manitoba. The modernization program following Manitoba Hydro's Churchill-Nelson River Hydro-Electric Project is described, focusing on the housing component of the process in the communities of Chemawawin, South Indian Lake, Cross Lake, Nelson House, Norway House, Split Lake, and York Landing. In these communities, the modernization process can be considered as a hydro-induced program of redevelopment. In each case, the community was forced to accept the consequences of Manitoba Hydro's development plan. From the flooding of traplines to the relocation of total settlements, the hydro operation has drastically altered the traditional way of life in the selected communities. Although the hydro developments have had a limited short-term positive impact (i.e. provision of employment or training), the impact has been generally negative. The case can be made that the housing component of the program has never clearly recognized the unique quality of native culture nor specific community needs. New housing, often the first priority in all seven communities studied, was too often neglected in favor of housing services. When new housing was made available, site development was geared to demands of modern servicing as opposed to the actual needs of local residents. 34 refs., 1 fig., 11 tabs

  18. Understanding of Danish passive houses based on pilot project Comfort Houses

    Energy Technology Data Exchange (ETDEWEB)

    Brunsgaard, C.

    2010-12-15

    The aim of the research is to investigate the notion of passive houses in Denmark. When this PhD thesis was initiated, the Danish building industry has just started to become interested in the passive house concept, but the knowledge was very limited. To be able to speed up the process of constructing Danish passive houses or other low energy concepts Saint-Gobain Isover Scandinavia took the initiative to the pilot project of the Comfort Houses, ten single-family houses constructed as passive houses, and wanted to share the knowledge with the building industry and other interested. This PhD thesis was a part of the strategy. If the concept of passive houses should be successfully promoted and achieve a significant sale in Denmark, it is believed that it is necessary to do a holistic approach. Besides energy savings and new structural solutions more qualitative aspects like architecture, everyday life and the future ways of living needs to be integrated in the future understanding of passive houses. This Ph.D. thesis therefore studies the following research question: What can the experience from the Comfort Houses enlighten about the future production and use of Danish passive houses? This understanding is achieved through studies of different study fields to be able to create a more holistic understanding of the concept both covering qualitative and quantitative analysis. The main focus will be on the study fields Design Process, Architecture and Everyday Life and the Indoor environment, which will answer the following sub-research questions: 1) How has the consortiums behind the Comfort Houses approached the design process according to teamwork, method and tools? And what barriers and possibilities lie within the approaches? 2) How do the occupants of the Comfort Houses experience the passive house architecture and the technical service systems? And has their everyday life changed by moving into a passive house? If so, how? 3) To what extent do the Comfort Houses

  19. Organohalogens in chlorinated cooling waters discharged from nuclear power stations

    International Nuclear Information System (INIS)

    Bean, R.M.; Mann, D.C.; Neitzel, D.A.

    1983-01-01

    For the power plant discharges studied to date, measured concentrations of trihalomethanes are lower than might be expected, particularly in cooling tower water, which can lose THMs to the atmosphere. In the cooling towers, where chlorine was added in higher concentrations and for longer residence times, halogenated phenols can contribute significantly to the total organic halogen content of the discharge. The way in which cooling towers are operated may also influence the production of halogenated phenols because they concentrate the incoming water by a factor of 4 or 5. In addition, the phenols, which act as a substrate for the halogenating agent, are also probably concentrated by the cooling tower operation and may be prevented from being biodegraded by addition of the same biocide that produces the halogenated phenols. 8 references, 4 tables

  20. Re-design, re-use and recycle of temporary houses

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Hakan [Department of Construction, Faculty of Technical Education, University of Abant Izzet Baysal, Duzce 81100 (Turkey)

    2007-01-15

    Disasters are recurring to global problems, which results in homelessness. The affected region had economical, environmental and social problems as well. In relief and reconstruction phases, the need for integrated management appeared in order to use the national sources actively and productively. Especially housing implementations had an important role for future development of the affected region. For accelerating the reconstruction of the region and forming a sustainable community, which maintains itself socially, environmentally and economically over time; energy usage for construction should be kept to a minimum. Past research in Turkey shows that the cost of temporary houses (to be used as the short term shelter) had a ratio of 10-15% of the total expenses of whole construction activity. For saving money and protecting the environment and conserving scarce resources, the affected region must consider the option of temporary houses to meet their short and long-term need during the reconstruction process. After the end of usage, temporary houses should be able to be re-used for the same or new function. This study is a test of re-design and re-use of a temporary housing site; by using recycled materials, minimum energy and voluntary participation so that this site can finally become a permanent housing site. (author)

  1. Vessel supporting structure for liquid metal cooled nuclear reactors

    International Nuclear Information System (INIS)

    Mahe, Armel; Jullien, Georges

    1974-01-01

    The supporting structure described is for a liquid metal cooled nuclear reactor, the vessel being of the type suspended to the end slab of the reactor. It includes a ring connected at one of its two ends to a single shell and at the other end to two shells. One of these three shells connected to the lower end of the ring forms the upper part of the vessel to be supported. The two other shells are embedded in two sperate parts of the slab. The ring and shell assembly is housed in an annular space provided in the end slab and separating it into two parts, namely a central part and a peripheral part [fr

  2. Cooled solar PV panels for output energy efficiency optimisation

    International Nuclear Information System (INIS)

    Peng, Zhijun; Herfatmanesh, Mohammad R.; Liu, Yiming

    2017-01-01

    Highlights: • Effects of cooling on solar PV performance have been experimentally investigated. • As a solar panel is cooled down, the electric output can have significant increase. • A cooled solar PV system has been proposed for resident application. • Life cycle assessment suggests the cost payback time of cooled PV can be reduced. - Abstract: As working temperature plays a critical role in influencing solar PV’s electrical output and efficacy, it is necessary to examine possible way for maintaining the appropriate temperature for solar panels. This research is aiming to investigate practical effects of solar PV surface temperature on output performance, in particular efficiency. Experimental works were carried out under different radiation condition for exploring the variation of the output voltage, current, output power and efficiency. After that, the cooling test was conducted to find how much efficiency improvement can be achieved with the cooling condition. As test results show the efficiency of solar PV can have an increasing rate of 47% with the cooled condition, a cooling system is proposed for possible system setup of residential solar PV application. The system performance and life cycle assessment suggest that the annual PV electric output efficiencies can increase up to 35%, and the annual total system energy efficiency including electric output and hot water energy output can increase up to 107%. The cost payback time can be reduced to 12.1 years, compared to 15 years of the baseline of a similar system without cooling sub-system.

  3. Family Open House

    Science.gov (United States)

    Search Family Open House Join us for an afternoon of science fun. The Fermilab Family Open House is a party for children of all ages to learn about the world of physics. The Open House is supported by Open House? Check out our YouTube video to learn more! Explore physics concepts with hands-on

  4. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  5. Sustainable renovation concepts for single-family houses

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Tommerup, Henrik M.; Svendsen, Svend

    , the financial possibilities of the homeowner etc. Calculation of packages of energy efficient renovation solutions targeted the three segments of houses show that primary energy use and heating bill can be reduced with up to about 75% or a factor 4 corresponding to the level of a new house or better. It seems...... that the passive house level can not quite be reached with standard solutions. They require that more ambitious measures are applied. The total investment needed to reduce the heating bill by a factor 4 including replacement of e.g. roof and windows is up to EUR 100,000. It is generally difficult to obtain...... be seen as a possibility to make it easy for the homeowner to comply with possible future requirements to realize far-reaching energy savings in connection with extensive renovations, provided that the building sector offers the solutions. Homeowners need someone to take care of all relevant steps...

  6. Mink's adaptation to group housing in practice

    DEFF Research Database (Denmark)

    Hansen, Steffen W; Møller, Steen Henrik

    2012-01-01

    In this project, we test the hypothesis whether mink populations with a higher social tolerance have been developed in practice and thus are better adapted to housing in stacked cages. The hypothesis has been tested by comparing the level of bite damages and bit marks in mink kept in pairs...... and in mink kept in social groups. In total, the project included 1,191 brown mink housed on four farms in up to five different types of social groups. The result showed that mink in groups had significantly more bite marks than mink kept in pairs, and that mink with bite wounds had significantly more bite...... marks than mink that did not haev bite wounds. Thus, based upon bite mark results, we cannot confirm the hypothesis that mink populations adapted to group housing have been developed. The number of mink that had died or had been removede during the test period, or that had bite wounds at the time...

  7. Housing First or no housing? Housing and homelessness at the end of alcohol and drug treatment.

    Science.gov (United States)

    Dyb, Evelyn

    2016-10-01

    The rate of alcohol and drug dependency is high among homeless persons in Norway as well as in other Western societies. National homeless surveys also show a certain correlation between discharge from institutions and homelessness. However, the rate of homelessness versus the rate with fixed abode at the end of specialised alcohol and drug treatment has not been examined using quantitative methods. A cross-sectional survey was conducted in alcohol and drug treatment units in the national health services and private clinics. The survey investigates the housing outcome at the end of treatment compared to the situation at the start of treatment using an individual questionnaire for patients ending treatment in a specific time window. Housing outcome is measured by the odds ratio of having a fixed abode at the end of treatment in relation to main intoxicating substance, type of treatment (in- and outpatient), completing versus cutting short the treatment, housing situation at the start of treatment, socioeconomic capital, mental health problems, individual plan, medical assisted treatment, and a set of background variables. The housing versus homeless situation hardly changes during the treatment period. In both a bivariate analysis and a simple multivariate model, principal intoxicating substance is the strongest predictor of having a fixed abode both before and after treatment. However, a more sophisticated analysis indicates that socioeconomic resources and social capital play along with the preferred intoxicating substance as predictors of having permanent housing. After more than a decade of a housing-led national homeless policy, and wide embracement of Housing First approaches in the European Union, homeless persons entering specialised alcohol and drug treatment are likely to return to the streets and hostels at the end of treatment. Access to housing after treatment is very limited for those lacking resources to solve their housing problem without assistance

  8. Verification of the Performance of a Vertical Ground Heat Exchanger Applied to a Test House in Melbourne, Australia

    Directory of Open Access Journals (Sweden)

    Koon Beng Ooi

    2017-10-01

    Full Text Available The ground heat exchanger is traditionally used as a heat source or sink for the heat pump that raises the temperature of water to about 50 °C to heat houses. However, in winter, the heating thermostat (temperature at which heating begins in the Australian Nationwide House Energy Rating Scheme (NatHERS is only 20 °C during daytime and 15 °C at night. In South-East Melbourne, the temperature at the bottom of a 50-meter-deep borehole has been recorded with an Emerson™ recorder at 17 °C. Melbourne has an annual average temperature of 15 °C, so the ground temperature increases by 2 °C per 50-m depth. A linear projection gives 23 °C at 200-m of depth, and as the average undisturbed temperature of the ground for a 400-m-deep vertical ground heat exchanger (VGHE. This study, by simulation and experimentation, aims to verify that the circulation of water in the VGHE’s U-tube to low-temperature radiators (LTRs could heat a house to thermal comfort. A literature review is included in the introduction. A simulation, using a model of a 60-m2 experimental house, shows that the daytime circulation of water in this VGHE/LTR-on-opposite-walls system during the 8-month cold half of the year, heats the indoors to NatHERS settings. Simulation for the cold half shows that this VGHE-LTR system could cool the indoors. Instead, a fan creating a cooling sensation of up to 4 °C is used so that the VGHE is available for the regeneration of heat extracted from the ground during the cold portion. Simulations for this hot portion show that a 3.4-m2 flat plate solar collector can collect more than twice the heat extracted from the ground in the cold portion. Thus, it can thus replenish the ground heat extracted for houses double the size of this 60-m2 experimental house. Therefore, ground heat is sustainable for family-size homes. Since no heat pump is used, the cost of VGHE-LTR systems could be comparable to systems using the ground source heat pump. Water

  9. Restaurant food cooling practices.

    Science.gov (United States)

    Brown, Laura Green; Ripley, Danny; Blade, Henry; Reimann, Dave; Everstine, Karen; Nicholas, Dave; Egan, Jessica; Koktavy, Nicole; Quilliam, Daniela N

    2012-12-01

    Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention's Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study.

  10. Restaurant Food Cooling Practices†

    Science.gov (United States)

    BROWN, LAURA GREEN; RIPLEY, DANNY; BLADE, HENRY; REIMANN, DAVE; EVERSTINE, KAREN; NICHOLAS, DAVE; EGAN, JESSICA; KOKTAVY, NICOLE; QUILLIAM, DANIELA N.

    2017-01-01

    Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention’s Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study. PMID:23212014

  11. Cooling tower calculations

    International Nuclear Information System (INIS)

    Simonkova, J.

    1988-01-01

    The problems are summed up of the dynamic calculation of cooling towers with forced and natural air draft. The quantities and relations are given characterizing the simultaneous exchange of momentum, heat and mass in evaporative water cooling by atmospheric air in the packings of cooling towers. The method of solution is clarified in the calculation of evaporation criteria and thermal characteristics of countercurrent and cross current cooling systems. The procedure is demonstrated of the calculation of cooling towers, and correction curves and the effect assessed of the operating mode at constant air number or constant outlet air volume flow on their course in ventilator cooling towers. In cooling towers with the natural air draft the flow unevenness is assessed of water and air relative to its effect on the resulting cooling efficiency of the towers. The calculation is demonstrated of thermal and resistance response curves and cooling curves of hydraulically unevenly loaded towers owing to the water flow rate parameter graded radially by 20% along the cross-section of the packing. Flow rate unevenness of air due to wind impact on the outlet air flow from the tower significantly affects the temperatures of cooled water in natural air draft cooling towers of a design with lower demands on aerodynamics, as early as at wind velocity of 2 m.s -1 as was demonstrated on a concrete example. (author). 11 figs., 10 refs

  12. House Price, House Quality and Economic Growth

    NARCIS (Netherlands)

    De Vries, P.; Boelhouwer, P.J.

    2010-01-01

    The literature on housing markets suggest that periods of economic growth are characterised by a demand for better housing quality and increasing prices. The basic principles of the theory are that the short-run price fluctuations occur due to market imperfection, while over the long term, causality

  13. Livable Housing Design: The voluntary provision of inclusive housing in Australia

    Directory of Open Access Journals (Sweden)

    Margaret Louise Ward

    2014-06-01

    Full Text Available This paper reports on a study of the voluntary provision of inclusive housing. The impetus for the study is the Livable Housing Design initiative, an agreement among Australian housing industry and community leaders in 2010 to a national guideline and voluntary strategy with a target to provide minimum access features in all new housing by 2020. Situated in and around Brisbane, Australia, the study problematises the assumption that the housing industry will respond voluntarily; an assumption which this study concludes is unfounded. The Livable Housing Design initiative asks individual agents to consider the needs of people beyond the initial contract, to proceed with objective reasoning and to do the right thing voluntarily. Instead, the study found that interviewees focused on their immediate contractual obligations, were reluctant to change established practices and saw little reason to do more than was legally required of them. This paper argues that the highly-competitive and risk-averse nature of the industry works against a voluntary approach for inclusive housing and, if the 2020 target of the Livable Housing Design.

  14. Liquid nitrogen-cooled diamond-wire concrete cutting. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    Liquid nitrogen-cooled diamond-wire concrete cutting can be used to cut through thick concrete walls, floors, and structures without using water to cool the cutting wire. The diamond wire is cooled with liquid nitrogen in a 0.9-m (3-ft) long by 7.6-cm (3-in.) diameter pipe housing. The nitrogen evaporates, so no contaminated liquid waste is generated. Other than the use of liquid nitrogen, the system is a conventional diamond-wire saw assembly with remote hydraulic controls. Setup of the hydraulic-powered drive wheel and the diamond wire for cutting requires a relatively short period of time using people with minimal training. Concrete dust generated during the cutting is considerable and requires control. The production rate of this improved technology is 0.78 m 2 /hr (8.4 ft 2 /hr). The production rates of traditional (baseline) water-cooled diamond-wire cutting and circular saw cutting technologies are 1.11 m 2 /hr (12 ft 2 /hr), and 0.45 m 2 /hr (4.8 ft 2 /hr), respectively. The liquid nitrogen-cooled system costs 189% more than conventional diamond-wire cutting if contaminated liquid wastes collection, treatment, and disposal are not accounted for with the baseline. The new technology was 310% more costly than a conventional diamond circular saw, under the conditions of this demonstration (no wastewater control). For cutting a 0.9-m x 3.7-m (3-ft x 12-ft) wall, the improved technology costs $17,000, while baseline diamond-wire cutting would cost $9,000 and baseline circular-saw cutting would cost $5,500. The improved system may cost less than the baseline technologies or may be comparable in cost if wastewater control is included

  15. Liquid nitrogen-cooled diamond-wire concrete cutting. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    Liquid nitrogen-cooled diamond-wire concrete cutting can be used to cut through thick concrete walls, floors, and structures without using water to cool the cutting wire. The diamond wire is cooled with liquid nitrogen in a 0.9-m (3-ft) long by 7.6-cm (3-in.) diameter pipe housing. The nitrogen evaporates, so no contaminated liquid waste is generated. Other than the use of liquid nitrogen, the system is a conventional diamond-wire saw assembly with remote hydraulic controls. Setup of the hydraulic-powered drive wheel and the diamond wire for cutting requires a relatively short period of time using people with minimal training. Concrete dust generated during the cutting is considerable and requires control. The production rate of this improved technology is 0.78 m{sup 2}/hr (8.4 ft{sup 2}/hr). The production rates of traditional (baseline) water-cooled diamond-wire cutting and circular saw cutting technologies are 1.11 m{sup 2}/hr (12 ft{sup 2}/hr), and 0.45 m{sup 2}/hr (4.8 ft{sup 2}/hr), respectively. The liquid nitrogen-cooled system costs 189% more than conventional diamond-wire cutting if contaminated liquid wastes collection, treatment, and disposal are not accounted for with the baseline. The new technology was 310% more costly than a conventional diamond circular saw, under the conditions of this demonstration (no wastewater control). For cutting a 0.9-m x 3.7-m (3-ft x 12-ft) wall, the improved technology costs $17,000, while baseline diamond-wire cutting would cost $9,000 and baseline circular-saw cutting would cost $5,500. The improved system may cost less than the baseline technologies or may be comparable in cost if wastewater control is included.

  16. Tech House

    Science.gov (United States)

    1978-01-01

    The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, loatedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

  17. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Magnusson Turner, Lena; Søholt, Susanne

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  18. The Special Importance of Housing Policy for the Housing Situation of Ethnic Minorities

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Turner, Lena Magnusson; Søholt, Susanne

    2013-01-01

    The purpose of this article is to uncover, whether housing policy has a special importance for immigrants, compared with the whole population, by comparing housing policies and immigrants’ housing outcomes in four Nordic countries: Denmark, Finland, Norway and Sweden. There are substantial...... population varies much. These differences can only to some extent be explained by income inequalities on the housing markets in the countries, inequalities that affect immigrants. Other important explanations of why immigrants perform worse on the housing market is the shortage of rental housing (Norway......’ housing options are strict needs test for social/public housing (Finland)....

  19. Dew Point Evaporative Comfort Cooling

    Science.gov (United States)

    2012-11-01

    Multiple DASs were installed at Fort Carson, and the data from all the sensors were stored and partially processed on Campbell Scientific Data Loggers. The...evaporative cooling technologies would be expected to easily overcome utility- scale water withdrawal rates. As an example, an evaluation of an...Ambient pressure Outdoor Setra 276 1% of full scale Pyranometer Horizontal Campbell Scientific CS300 5% of daily total The OAT measurement has an

  20. A small scale remote cooling system for a superconducting cyclotron magnet

    Science.gov (United States)

    Haug, F.; Berkowitz Zamorra, D.; Michels, M.; Gomez Bosch, R.; Schmid, J.; Striebel, A.; Krueger, A.; Diez, M.; Jakob, M.; Keh, M.; Herberger, W.; Oesterle, D.

    2017-02-01

    Through a technology transfer program CERN is involved in the R&D of a compact superconducting cyclotron for future clinical radioisotope production, a project led by the Spanish research institute CIEMAT. For the remote cooling of the LTc superconducting magnet operating at 4.5 K, CERN has designed a small scale refrigeration system, the Cryogenic Supply System (CSS). This refrigeration system consists of a commercial two-stage 1.5 W @ 4.2 K GM cryocooler and a separate forced flow circuit. The forced flow circuit extracts the cooling power of the first and the second stage cold tips, respectively. Both units are installed in a common vacuum vessel and, at the final configuration, a low loss transfer line will provide the link to the magnet cryostat for the cooling of the thermal shield with helium at 40 K and the two superconducting coils with two-phase helium at 4.5 K. Currently the CSS is in the testing phase at CERN in stand-alone mode without the magnet and the transfer line. We have added a “validation unit” housed in the vacuum vessel of the CSS representing the thermo-hydraulic part of the cyclotron magnet. It is equipped with electrical heaters which allow the simulation of the thermal loads of the magnet cryostat. A cooling power of 1.4 W at 4.5 K and 25 W at the thermal shield temperature level has been measured. The data produced confirm the design principle of the CSS which could be validated.

  1. Exploring the Housing Needs of Older People in Standard and Sheltered Social Housing.

    Science.gov (United States)

    Fox, Siobhan; Kenny, Lorna; Day, Mary Rose; O'Connell, Cathal; Finnerty, Joe; Timmons, Suzanne

    2017-01-01

    Objective: Our home can have a major impact on our physical and mental health; this is particularly true for older people who may spend more time at home. Older people in social (i.e., public) housing are particularly vulnerable. Housing options for older people in social housing include standard design dwellings or specially designed "sheltered housing." The most suitable housing model should be identified, with older people consulted in this process. Method: Survey of older people (aged ≥60) living in standard or sheltered social housing. Data were analyzed using descriptive and inferential statistics in SPSS Version 22. Results: Overall, 380 surveys were returned (response rate = 47.2%). All older people had similar housing needs. Those in sheltered housing were more satisfied with the physical home design and reported more positive outcomes. Older people in standard housing were less likely to have necessary adaptations to facilitate aging-in-place. Discussion: Older people in standard housing reported more disability/illnesses, are worried about the future, and felt less safe at home. However, few wanted to move, and very few viewed sheltered housing as an alternative, suggesting limited knowledge about their housing options. Future social housing designs should be flexible, that is, adaptable to the needs of the tenants over time.

  2. Farmers' exposure to dusts and gases in modern Finnish cubicle cow houses

    Directory of Open Access Journals (Sweden)

    K. LOUHELAINEN

    2008-12-01

    Full Text Available The occurrence of airborne dust, gases, microbes, endotoxin and bovine epithelial antigens (BEA, BDA20 was studied in 26 modern, mainly cubicle, cow houses. Air samples of total dust, total spores, endotoxin and bovine epithelial allergens were collected on membrane filters with portable or piston pumps and analyzed with appropriate methods. Concentrations of gases (ammonia, carbon dioxide, hydrogen sulfide were measured with diffusion tubes. Airborne viable spores were collected with a cascade impactor on five selective culture media for the identification of xerophilic, mesophilic and thermotolerant fungi and thermophilic actinomycetes. The geometric mean concentrations of total dust, BEA and BDA20 were 0.2-1.9 mg/m 3 , 5.2- 9.7 mg/m 3 and 50-260 ng/m 3 , respectively. The mean concentrations of ammonia and carbon dioxide were between 2.8-15 ppm and 2200-3200 ppm, respectively. The geometric mean of endotoxins was 19 ng/m 3 and the concentrations of fungi were at the 10 1 -10 3 cfu/m 3 level. In general, the variation in concentrations of total dust, viable fungi and endotoxin was large. The concentrations of total dust and fungi were lower than in earlier studies. Thus new cubicle houses provide a better working environment with regard to airborne hazards than the traditional cow houses.;

  3. Cooling Tower Overhaul of Secondary Cooling System in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Chul; Lee, Young Sub; Jung, Hoan Sung; Lim, In Chul [KAERI, Daejeon (Korea, Republic of)

    2007-07-01

    HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 .deg. C in summer and the reactor is operated with the full power.

  4. Cooling Performance of ALIP according to the Air or Sodium Cooling Type

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Huee-Youl; Yoon, Jung; Lee, Tae-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    ALIP pumps the liquid sodium by Lorentz force produced by the interaction of induced current in the liquid metal and their associated magnetic field. Even though the efficiency of the ALIP is very low compared to conventional mechanical pumps, it is very useful due to the absence of moving parts, low noise and vibration level, simplicity of flow rate regulation and maintenance, and high temperature operation capability. Problems in utilization of ALIP concern a countermeasure for elevation of internal temperature of the coil due to joule heating and how to increase magnetic flux density of Na channel gap. The conventional ALIP usually used cooling methods by circulating the air or water. On the other hand, GE-Toshiba developed a double stator pump adopting the sodium-immersed self-cooled type, and it recovered the heat loss in sodium. Therefore, the station load factor of the plant could be reduced. In this study, the cooling performance with cooling types of ALIP is analyzed. We developed thermal analysis models to evaluate the cooling performance of air or sodium cooling type of ALIP. The cooling performance is analyzed for operating parameters and evaluated with cooling type. 1-D and 3-D thermal analysis model for IHTS ALIP was developed, and the cooling performance was analyzed for air or sodium cooling type. The cooling performance for air cooling type was better than sodium cooling type at higher air velocity than 0.2 m/s. Also, the air temperature of below 270 .deg. demonstrated the better cooling performance as compared to sodium.

  5. Persistence of vancomycin-resistant enterococci (VRE) in broiler houses after the avoparcin ban

    DEFF Research Database (Denmark)

    Heuer, Ole Eske; Pedersen, Karl; Jensen, Lars Bogø

    2002-01-01

    The glycopeptide growth promoter avoparcin was banned from animal production in the EU in 1997 due to concern for the spread of vancomycin-resistant enterococci (VRE) from food animals to humans. In recent Norwegian and Danish studies, extensive occurrence of VRE on broiler farms and in broiler......, and disinfection of the houses between rotations, and two consecutive broiler flocks from each house were sampled by taking cloacal swabs from the broilers at the time of slaughter. A total of 69 vancomycin-resistant Enterococcus faecium isolates obtained from broiler flocks and broiler houses were subjected......-isolates from different broiler houses and from flocks reared in different houses appeared to be genetically unrelated. These findings indicated that VRE was transmitted between consecutive broiler flocks by clones of resistant. bacteria surviving in the broiler houses despite cleaning and disinfection between...

  6. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    International Nuclear Information System (INIS)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2005-01-01

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a non-cool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential (NR) building with a low-sloped roof yields average annual cooling energy savings of approximately 3.2 kW h/m 2 (300 kW h/1000 ft 2 ), average annual natural gas deficits of 5.6 MJ/m 2 (4.9 therm/1000 ft 2 ), average annual source energy savings of 30 MJ/m 2 (2.6 MBTU/1000 ft 2 ), and average peak power demand savings of 2.1 W/m 2 (0.19 kW/1000 ft 2 ). The 15-year net present value (NPV) of energy savings averages $4.90/m 2 ($450/1000 ft 2 ) with time-dependent valuation (TDV), and $4.00/m 2 ($370/1000 ft 2 ) without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV+equipment savings) rises to $5.90/m 2 ($550/1000 ft 2 ) with TDV, and to $5.00/m 2 ($470/1000 ft 2 ) without TDV. Total savings range from 1.90 to 8.30 $/m 2 (0.18-0.77 $/ft 2 ) with TDV, and from 1.70 to 7.10 $/m 2 (0.16-0.66 $/ft 2 ) without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00-2.20 $/m 2 (0.00-0.20 $/ft 2 ). Cool roofs with premiums up to $2.20/m 2 ($0.20/ft 2 ) are expected to be cost effective in climate zones 2-16; those with premiums not exceeding $1.90/m 2 ($0.18/ft 2 ) are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California

  7. Film cooling air pocket in a closed loop cooled airfoil

    Science.gov (United States)

    Yu, Yufeng Phillip; Itzel, Gary Michael; Osgood, Sarah Jane; Bagepalli, Radhakrishna; Webbon, Waylon Willard; Burdgick, Steven Sebastian

    2002-01-01

    Turbine stator vane segments have radially inner and outer walls with vanes extending between them. The inner and outer walls are compartmentalized and have impingement plates. Steam flowing into the outer wall plenum passes through the impingement plate for impingement cooling of the outer wall upper surface. The spent impingement steam flows into cavities of the vane having inserts for impingement cooling the walls of the vane. The steam passes into the inner wall and through the impingement plate for impingement cooling of the inner wall surface and for return through return cavities having inserts for impingement cooling of the vane surfaces. To provide for air film cooing of select portions of the airfoil outer surface, at least one air pocket is defined on a wall of at least one of the cavities. Each air pocket is substantially closed with respect to the cooling medium in the cavity and cooling air pumped to the air pocket flows through outlet apertures in the wall of the airfoil to cool the same.

  8. Maximum Exergetic Efficiency Operation of a Solar Powered H2O-LiBr Absorption Cooling System

    Directory of Open Access Journals (Sweden)

    Camelia Stanciu

    2017-12-01

    Full Text Available A solar driven cooling system consisting of a single effect H2O-LiBr absorbtion cooling module (ACS, a parabolic trough collector (PTC, and a storage tank (ST module is analyzed during one full day operation. The pressurized water is used to transfer heat from PTC to ST and to feed the ACS desorber. The system is constrained to operate at the maximum ACS exergetic efficiency, under a time dependent cooling load computed on 15 July for a one storey house located near Bucharest, Romania. To set up the solar assembly, two commercial PTCs were selected, namely PT1-IST and PTC 1800 Solitem, and a single unit ST was initially considered. The mathematical model, relying on the energy balance equations, was coded under Engineering Equation Solver (EES environment. The solar data were obtained from the Meteonorm database. The numerical simulations proved that the system cannot cover the imposed cooling load all day long, due to the large variation of water temperature inside the ST. By splitting the ST into two units, the results revealed that the PT1-IST collector only drives the ACS between 9 am and 4:30 pm, while the PTC 1800 one covers the entire cooling period (9 am–6 pm for optimum ST capacities of 90 kg/90 kg and 90 kg/140 kg, respectively.

  9. Traditional Values and their Adaptation in Social Housing Design: Towards a New Typology and Establishment of ‘Air House’ Standard in Malaysia

    Directory of Open Access Journals (Sweden)

    Mohd Firrdhaus Mohd Sahabuddin

    2015-07-01

    Full Text Available Large migration from rural areas to urban areas like Kuala Lumpur has led to some implications for economic, social and cultural development. This high population has placed enormous demand on the existing housing stocks, especially for low-income groups.  However, some issues arise, one of which is overheated indoor air temperature. This problem contributes to the high-energy usage that forces huge sums of money to be spent on cooling the house by using mechanical equipment. Therefore, this study focuses on thermal comfort in social housing, and incorporates traditional values into its design to achieve a certain measurement of natural ventilation in a house. From the study, the carbon emission and energy consumption for an air-conditioned house is 67%, 66% higher than a naturally ventilated house. Therefore, this research has come up with a new typology design, which has a large exposed wall area and full-length openings on the opposite walls to increase cross ventilation. At the end of this research, the measurement of thermal comfort for a naturally ventilated building called ‘Air House’ has been identified.

  10. Mapping the dark matter in the NGC 5044 group with ROSAT: Evidence for a nearly homogeneous cooling flow with a cooling wake

    Science.gov (United States)

    David, Laurence P.; Jones, Christine; Forman, William; Daines, Stuart

    1994-01-01

    The NGC 5044 group of galaxies was observed by the ROSAT Position Sensitive Proportional Counter (PSPC) for 30 ks during its reduced pointed phase (1991 July). Due to the relatively cool gas temperature in the group (kT = 0.98 +/- 0.02 keV) and the excellent photon statistics (65,000 net counts), we are able to determine precisely a number of fundamental properties of the group within 250 kpc of the central galaxy. In particular, we present model-independent measurements of the total gravitating mass, the temperature and abundance profiles of the gas, and the mass accretion rate. Between 60 and 250 kpc, the gas is nearly isothermal with T varies as r(exp (-0.13 +/- 0.03)). The total gravitating mass of the group can be unambiguously determined from the observed density and temperature profiles of the gas using the equation of hydrostatic equilibrium. Within 250 kpc, the gravitating mass is 1.6 x 10(exp 13) solar mass, yielding a mass-to-light ratio of 130 solar mass/solar luminosity. The baryons (gas and stars) comprise 12% of the total mass within this radius. At small radii, the temperature clearly increases outward and attains a maximum value at 60 kpc. The positive temperature gradient in the center of the group confirms the existence of a cooling flow. The cooling flow region extends well beyond the temperature maximum with a cooling radius between 100 and 150 kpc. There are two distinct regions in the cooling flow separated by the temperature maximum. In the outer region, the gas is nearly isothermal with a unifor m Fe abundance of approximately 80% solar, the flow is nearly homogeneous with dot-M= 20 to 25 solar mass/year, the X-ray contours are spherically symmetric, and rho(sub gas) varies as r(exp -1.6). In the inner region, the temperature profile has a positive gradient, the mass accretion rate decreases rapidly inward, the gas density profile is steeper, and the X-ray image shows some substrucutre. NGC 5044 is offset from the centroid of the outer X

  11. Economizer Based Data Center Liquid Cooling with Advanced Metal Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Chainer

    2012-11-30

    A new chiller-less data center liquid cooling system utilizing the outside air environment has been shown to achieve up to 90% reduction in cooling energy compared to traditional chiller based data center cooling systems. The system removes heat from Volume servers inside a Sealed Rack and transports the heat using a liquid loop to an Outdoor Heat Exchanger which rejects the heat to the outdoor ambient environment. The servers in the rack are cooled using a hybrid cooling system by removing the majority of the heat generated by the processors and memory by direct thermal conduction using coldplates and the heat generated by the remaining components using forced air convection to an air- to- liquid heat exchanger inside the Sealed Rack. The anticipated benefits of such energy-centric configurations are significant energy savings at the data center level. When compared to a traditional 10 MW data center, which typically uses 25% of its total data center energy consumption for cooling this technology could potentially enable a cost savings of up to $800,000-$2,200,000/year (assuming electricity costs of 4 to 11 cents per kilowatt-hour) through the reduction in electrical energy usage.

  12. Essays on Housing Markets

    DEFF Research Database (Denmark)

    Bäckman, Claes

    In Denmark and in many countries around the world, housing markets are of considerable importance for households and policy-makers alike. As the boom and bust in the US and Danish housing market so aptly demonstrated, disruptions in the housing market potentially have wide-ranging consequences...... for individual households and for the aggregate economy. Housing is important because we all have to live somewhere, but also because it serves as a considerable source of both wealth and debt. As such, housing market policy can not only create vast benefits for many, but can also have substantial negative...... impacts for all, and should therefore be a topic of major interest for economists and policy makers alike. This Ph.D. thesis, entitled “Essays on Housing Markets”, analyzes the Danish housing market during the 2000s, with a focus on how policy changes affected house prices and how changes in house prices...

  13. The bishops and housing.

    Science.gov (United States)

    Shellabarger, Thomas

    2005-01-01

    According to Catholic social teaching, housing is not a commodity but a human right. To ensure that all people--especially low-income elderly and other vulnerable populations--have access to affordable housing, the church has established a variety of programs, services, and advocacy efforts. Much of this work is based on key concepts: preserving existing housing stock, creating new programs to provide more options for the underserved, empowering residents and communities to deal with housing issues, establishing partnerships to make organizations' efforts more successful, making housing affordable, and ending discrimination in housing. Although church ministries, community groups, the private sector, and other players must work together to find solutions to the housing crisis, federal leadership is essential. Especially with the housing affordability gap growing and the U.S. population aging, the federal government must provide the resources, leadership, and direction for effective housing solutions.

  14. The milk quality and feasebility analysis of loose housing dairy cows - a case study

    Directory of Open Access Journals (Sweden)

    Marjan Janžekovič

    2006-03-01

    Full Text Available The aim of the study was technological and economical analysis of free range cow breeding. The case study analyzed two different systems of holstein-friesian dairy cows breeding. The model total costs enterprise budget was developed for evaluation of economic feasibility of loose housing dairy cows in comparison with tied cow breeding system. Computer supported calculation enabled estimation of the most important economical parameters (net return, total cost, and coefficient of economics. Results obtained show that (at observed input parameters loose housing system is economically feasible, if there is a minimum of 41 dairy cows with an average milk production of 8610 kg per cow. It was also established that cows need approximately 6 months to fully adapt to the loose housing system.

  15. Effects of evaporative cooling on the regulation of body water and milk production in crossbred Holstein cattle in a tropical environment

    Science.gov (United States)

    Chaiyabutr, N.; Chanpongsang, S.; Suadsong, S.

    2008-09-01

    The aim of this study was to determine how evaporative cooling modifies body function with respect to water metabolism and other variables relevant to milk synthesis in crossbred cattle. The study was conducted on two groups of 0.875HF:0.125RS crossbred Holstein cattle (87.5%) housed in an open-sided barn with a tiled roof (non-cooled animals) and in a close-sided barn under an evaporative cooling system (cooled animals). The maximum ambient temperature and relative humidity for the non-cooled group were 33°C and 61%, with the corresponding values for the evaporatively cooled barn being 28°C and 84%, respectively. The temperature humidity index (THI) of under non-cooled conditions was higher ( P glucose and triglyceride of cooled animals were not significantly different compared with values for non-cooled animals. No differences were seen in plasma hormonal levels for triiodotyronine (T3) and insulin-like growth factor-1 (IGF-1), but plasma cortisol and thyroxine (T4) levels tended to be lower in non-cooled animals. This study suggests that low cooling temperature accompanied by high humidity influences a galactopoietic effect, in part through increases in ECF, blood volume and plasma volume in association with an increase in DMI, which partitions the distribution of nutrients to the mammary gland for milk synthesis. Cooled animals were unable to maintain high milk yield as lactation advances even though a high level of body fluids was maintained during long-term cooled exposure. The decline in milk yield, coinciding with a decrease in net energy for lactation as lactation advances, could be attributed to a local change within the mammary gland.

  16. ECOHEATCOOL Work Package 5. Possibilities with more district cooling in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Dalin, Paer; Rubenhag, Anders [Capital Cooling Europe AB, Stockholm (SE)] (and others)

    2006-07-01

    The main idea of district cooling is to use local sources that otherwise would be wasted or not used, in order to offer for the local market a competitive and high-efficient alternative to the traditional cooling solutions. The centralisation of cooling production is a prerequisite to reach a high efficiency insofar as it makes possible to use 'free cooling' or waste heat sources. A district cooling system can reach an efficiency rate typically 5 or even 10 times higher than traditional local electricity-driven equipments. The benefits of District cooling are addressing the society, property owners and utilities. For society: environment protection: reduction of CO{sub 2} emission and environmental hazardous refrigerants, enhanced aesthetics and an improved local environment by reducing the noise; security of supply: avoid investments in summer electricity peak capacities, enhance the reliability of the electricity supply competitiveness: development of a new energy service which should compete freely with the conventional alternatives. For property owners/customers: more economical way of cooling; corporate social responsibility (CSR) policy; Improved value for the cooled building. For utilities: competitive product that gives long term stable business; An innovative energy service to attract new and existing customers; Fits perfectly into Corporate Social Responsibility. Is a 25 % market share of District Cooling, of the total cooling market in Europe 32-165 TWh/year a possibility for 2020? There are some arguments in favour of such development but also barriers to be overcome: Strong driving force from property owners; Potential for cooling sources is larger than 500TWh: Natural cooling (free cooling including the possibility for seasonal storage): over 260TWh; Residual cooling (especially from LNG): over 30TWh; Industrial cooling (CHP, waste incineration, industrial residual); over 260 TWh. Legitimate - naturally integrated in the local energy policy

  17. The value of retrofitting carbon-saving measures into fuel poor social housing

    International Nuclear Information System (INIS)

    Jenkins, D.P.

    2010-01-01

    With current fuel poverty and carbon-saving policies continuing to miss their targets in the UK, the synergy between the two problems is investigated to highlight an approach that could be mutually beneficial. Focussing on the 550,000 fuel poor socially housed dwellings in the UK, costs of between Pounds 3.9 and Pounds 17.5 bn are estimated as the required capital investment for achieving deep-cut carbon savings (defined as at least 50%) across this section of the housing stock, with a potential total annual carbon saving of 1.7 MtCO 2 . It is assumed that such costs would be largely (or totally) state-funded, though additional private investment could clearly increase the possible carbon savings across this section of the stock. The use of these socially housed fuel poor dwellings as low-carbon exemplars is discussed, and benefits for the private housing sector are postulated. The study also focuses on the problem of installing non-cost effective measures, i.e. technologies that would not currently be encouraged by existing subsidy schemes, but which might be necessary for achieving large carbon-saving targets.

  18. Coherent electron cooling

    Energy Technology Data Exchange (ETDEWEB)

    Litvinenko,V.

    2009-05-04

    Cooling intense high-energy hadron beams remains a major challenge in modern accelerator physics. Synchrotron radiation is still too feeble, while the efficiency of two other cooling methods, stochastic and electron, falls rapidly either at high bunch intensities (i.e. stochastic of protons) or at high energies (e-cooling). In this talk a specific scheme of a unique cooling technique, Coherent Electron Cooling, will be discussed. The idea of coherent electron cooling using electron beam instabilities was suggested by Derbenev in the early 1980s, but the scheme presented in this talk, with cooling times under an hour for 7 TeV protons in the LHC, would be possible only with present-day accelerator technology. This talk will discuss the principles and the main limitations of the Coherent Electron Cooling process. The talk will describe the main system components, based on a high-gain free electron laser driven by an energy recovery linac, and will present some numerical examples for ions and protons in RHIC and the LHC and for electron-hadron options for these colliders. BNL plans a demonstration of the idea in the near future.

  19. Overview of direct air free cooling and thermal energy storage potential energy savings in data centres

    International Nuclear Information System (INIS)

    Oró, Eduard; Depoorter, Victor; Pflugradt, Noah; Salom, Jaume

    2015-01-01

    In the last years the total energy demand of data centres has experienced a dramatic increase which is expected to continue. This is why data centres industry and researchers are working on implementing energy efficiency measures and integrating renewable energy to overcome energy dependence and to reduce operational costs and CO 2 emissions. The cooling system of these unique infrastructures can account for 40% of the total energy consumption. To reduce the energy consumption, free cooling strategies are used more and more, but so far there has been little research about the potential of thermal energy storage (TES) solutions to match energy demand and energy availability. Hence, this work intends to provide an overview of the potential of the integration of direct air free cooling strategy and TES systems into data centres located at different European locations. For each location, the benefit of using direct air free cooling is evaluated energetically and economically for a data centre of 1250 kW. The use of direct air free cooling is shown to be feasible. This does not apply the TES systems by itself. But when using TES in combination with an off-peak electricity tariff the operational cooling cost can be drastically reduced. - Highlights: • The total annual hours for direct air free cooling in data centres are calculated. • The potential of TES integration in data centres is evaluated. • The implementation of TES to store the ambient air cold is not recommended. • TES is feasible if combined with redundant chillers and off-peak electricity price. • The cooling electricity cost is being reduced up to 51%, depending on the location

  20. Man-portable personal cooling garment based on vacuum desiccant cooling

    International Nuclear Information System (INIS)

    Yang Yifan; Stapleton, Jill; Diagne, Barbara Thiané; Kenny, Glen P.; Lan, Christopher Q.

    2012-01-01

    A man-portable personal cooling garment based on the concept of vacuum desiccant cooling (VDC) was developed. It was demonstrated with cooling pads that a cooling capacity of 373.1 W/m 2 could be achieved in an ambient environment of 37 °C. Tests with human subjects wearing prototype cooling garments consisting of 12 VDC pads with an overall weight of 3.4 kg covering 0.4 m 2 body surface indicate that the garment could maintain a core temperature substantially lower than the control when the workload was walking on a treadmill of 2% inclination at 3 mph. The exercise was carried out in an environment of 40 °C and 50% relative humidity (RH) for 60 min. Tests also showed that the VDC garment could effectively reduce the metabolic heat accumulation in body with subject wearing heavily insulated nuclear, biological and chemical (NBC) suit working in the heat and allow the participant to work safely for 60 min, almost doubling the safe working time of the same participant when he wore NBC suit only. - Highlights: ► Heat stress mitigation is important for workers health, safety, and performance. ► Vacuum desiccant cooling (VDC) a novel concept for personal cooling. ► VDC garment man-portable and more efficient than commercial ice/pad vest. ► VDC garment suitable for personal cooling with NBC suit.

  1. Influence of Indoor Environment and Occupant Behaviour on Energy Consumption in Passive House Apartments

    DEFF Research Database (Denmark)

    Skød Søvsø, Asger; Peuhkuri, Ruut; Andersen, Rune Korsholm

    2015-01-01

    In 2012 Køge Boligselskab built 9 building blocks totalling 126 passive house apartments. Their monitored space heating demand (SHD) has been a lot higher than the passive house requirements. The aim of this study was to identify why, and how it relates to indoor environment and occupant behaviour...

  2. Laser cooling of solids

    CERN Document Server

    Petrushkin, S V

    2009-01-01

    Laser cooling is an important emerging technology in such areas as the cooling of semiconductors. The book examines and suggests solutions for a range of problems in the development of miniature solid-state laser refrigerators, self-cooling solid-state lasers and optical echo-processors. It begins by looking at the basic theory of laser cooling before considering such topics as self-cooling of active elements of solid-state lasers, laser cooling of solid-state information media of optical echo-processors, and problems of cooling solid-state quantum processors. Laser Cooling of Solids is an important contribution to the development of compact laser-powered cryogenic refrigerators, both for the academic community and those in the microelectronics and other industries. Provides a timely review of this promising field of research and discusses the fundamentals and theory of laser cooling Particular attention is given to the physics of cooling processes and the mathematical description of these processes Reviews p...

  3. Simulation Study of Discharging PCM Ceiling Panels through Night - time Radiative Cooling

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Grossule, F.

    2016-01-01

    demand. In the present simulation study, the coupling of nighttime radiative cooling with PCM for cooling an office room was investigated. For cooling water through nighttime radiative cooling two types of solar panels were utilized, an unglazed solar collector and photovoltaic/thermal (PV/T) panels...... provided by the PV/T panels was 43 W/m2 for Copenhagen, while for Milan and Athens it was 36 W/m2 and 34 W/m2, respectively. The cooling power of the unglazed solar collector was negligible. Finally, the total electricity produced in Copenhagen for the simulated period was 371 kWh, while for Milan...... and increase use of renewable energy sources. The aim is that by 2020 all new buildings should be nearly zero-energy buildings. A solution that could contribute to this is the combination of photovoltaic panels for the production of electricity and phase change material (PCM) for the reduction of peak cooling...

  4. 120 Years of U.S. Residential Housing Stock and Floor Space.

    Directory of Open Access Journals (Sweden)

    Maria Cecilia P Moura

    Full Text Available Residential buildings are a key driver of energy consumption and also impact transportation and land-use. Energy consumption in the residential sector accounts for one-fifth of total U.S. energy consumption and energy-related CO2 emissions, with floor space a major driver of building energy demands. In this work a consistent, vintage-disaggregated, annual long-term series of U.S. housing stock and residential floor space for 1891-2010 is presented. An attempt was made to minimize the effects of the incompleteness and inconsistencies present in the national housing survey data. Over the 1891-2010 period, floor space increased almost tenfold, from approximately 24,700 to 235,150 million square feet, corresponding to a doubling of floor space per capita from approximately 400 to 800 square feet. While population increased five times over the period, a 50% decrease in household size contributed towards a tenfold increase in the number of housing units and floor space, while average floor space per unit remains surprisingly constant, as a result of housing retirement dynamics. In the last 30 years, however, these trends appear to be changing, as household size shows signs of leveling off, or even increasing again, while average floor space per unit has been increasing. GDP and total floor space show a remarkably constant growth trend over the period and total residential sector primary energy consumption and floor space show a similar growth trend over the last 60 years, decoupling only within the last decade.

  5. To cool, but not too cool: that is the question--immersion cooling for hyperthermia.

    Science.gov (United States)

    Taylor, Nigel A S; Caldwell, Joanne N; Van den Heuvel, Anne M J; Patterson, Mark J

    2008-11-01

    Patient cooling time can impact upon the prognosis of heat illness. Although ice-cold-water immersion will rapidly extract heat, access to ice or cold water may be limited in hot climates. Indeed, some have concerns regarding the sudden cold-water immersion of hyperthermic individuals, whereas others believe that cutaneous vasoconstriction may reduce convective heat transfer from the core. It was hypothesized that warmer immersion temperatures, which induce less powerful vasoconstriction, may still facilitate rapid cooling in hyperthermic individuals. Eight males participated in three trials and were heated to an esophageal temperature of 39.5 degrees C by exercising in the heat (36 degrees C, 50% relative humidity) while wearing a water-perfusion garment (40 degrees C). Subjects were cooled using each of the following methods: air (20-22 degrees C), cold-water immersion (14 degrees C), and temperate-water immersion (26 degrees C). The time to reach an esophageal temperature of 37.5 degrees C averaged 22.81 min (air), 2.16 min (cold), and 2.91 min (temperate). Whereas each of the between-trial comparisons was statistically significant (P < 0.05), cooling in temperate water took only marginally longer than that in cold water, and one cannot imagine that the 45-s cooling time difference would have any meaningful physiological or clinical implications. It is assumed that this rapid heat loss was due to a less powerful peripheral vasoconstrictor response, with central heat being more rapidly transported to the skin surface for dissipation. Although the core-to-water thermal gradient was much smaller with temperate-water cooling, greater skin and deeper tissue blood flows would support a superior convective heat delivery. Thus, a sustained physiological mechanism (blood flow) appears to have countered a less powerful thermal gradient, resulting in clinically insignificant differences in heat extraction between the cold and temperate cooling trials.

  6. On-farm comparisons of different cleaning protocols in broiler houses.

    Science.gov (United States)

    Luyckx, K Y; Van Weyenberg, S; Dewulf, J; Herman, L; Zoons, J; Vervaet, E; Heyndrickx, M; De Reu, K

    2015-08-01

    The present study evaluated the effectiveness of 4 cleaning protocols designed to reduce the bacteriological infection pressure on broiler farms and prevent food-borne zoonoses. Additionally, difficult to clean locations and possible sources of infection were identified. Cleaning and disinfection rounds were evaluated in 12 broiler houses on 5 farms through microbiological analyses and adenosine triphosphate hygiene monitoring. Samples were taken at 3 different times: before cleaning, after cleaning, and after disinfection. At each sampling time, swabs were taken from various locations for enumeration of the total aerobic flora and Enterococcus species pluralis ( SPP:). In addition, before cleaning and after disinfection, testing for Escherichia coli and Salmonella was carried out. Finally, adenosine triphosphate swabs and agar contact plates for total aerobic flora counts were taken after cleaning and disinfection, respectively. Total aerobic flora and Enterococcus spp. counts on the swab samples showed that cleaning protocols which were preceded by an overnight soaking with water caused a higher bacterial reduction compared to protocols without a preceding soaking step. Moreover, soaking of broiler houses leads to less water consumption and reduced working time during high pressure cleaning. No differences were found between protocols using cold or warm water during cleaning. Drinking cups, drain holes, and floor cracks were identified as critical locations for cleaning and disinfection in broiler houses. © 2015 Poultry Science Association Inc.

  7. Housing preferences of young adults in Indonesia: housing attributes and consequences

    Science.gov (United States)

    Farasa, N.; Kusuma, H. E.

    2018-03-01

    Nowadays, the housing demand of young adults in Indonesia is important issues for the sustainable development of the market. Facing differences of life phases, such as marriage, leaving home after graduation, and new job positioning, young adults become the main segment facing constant housing choice decisions in the housing market. In their particular phase of life, young adults have distinct preferences for housing attributes which bring a great influence on their lives in the future. Data was gathered from a survey questionnaire that was answered by 180 young adults in Indonesia, ranging from age 22-33 years. The findings suggest that the green area and view, location, simplicity, home design, and accessibility are the significant parts as housing attributes for young adults’ housing preferences in Indonesia. The effect of these attributes has many consequences such as security, personalization, mood/ambiance, maintenance, interaction, image, flexibility, environmental, economy, durability, convenience, comfort, and circulation. The biggest group of young adults who prefer comfort as their wanted consequences tend to have high preferences on housing attributes of the green area and view, and simplicity.

  8. Compensation of equipment housing elements of reactor units with heavy liquid metal coolant vessel temperature deformations

    International Nuclear Information System (INIS)

    Lebedevich, V.; Ahmetshin, M.; Mendes, D.; Kaveshnikov, S.; Vinogradov, A.

    2015-01-01

    In Russia a lot of different versions of fast reactors (FRs) are investigated and one of these is FR cooled by liquid lead and liquid lead-bismuth alloy. In this poster we are interested by FR with concrete vessel; its components are placed in cavities inside the vessel, and connected by a channel system. During the installation the equipment components are placed in several equipment housings. Between these housings there are cavities with coolant. The alignment of the housings should be provided. It can be broken by irregular concrete vessel heating during FR starting or other transition regimes. Our goal is to suggest a list of designing steps to compensate temperature deformations of equipment housing elements. A simplified model of equipment housing was suggested. It consists of two cylinders - tunnels in the concrete vessel, separated by a cavity filled by coolant and inert gas. The bottom part was considered as heated to 420 C. degrees while in the top part temperature decreased to 45 C. degrees (on the concrete surface). According to this data, results show that temperature gradient leads to a concrete layer dislocation of about 12.5 mm, which can lead to damage and breaking alignment. We propose the following solution to compensate for temperature deformation: -) to chisel out part of the upper top of the insulating concrete; -) to install an adequate misalignment of equipment housing elements preliminary; and -) to use a torsion system like a piston-type device for providing additional strength in order to compensate deformation and vibrations

  9. Spray cooling

    International Nuclear Information System (INIS)

    Rollin, Philippe.

    1975-01-01

    Spray cooling - using water spraying in air - is surveyed as a possible system for make-up (peak clipping in open circuit) or major cooling (in closed circuit) of the cooling water of the condensers in thermal power plants. Indications are given on the experiments made in France and the systems recently developed in USA, questions relating to performance, cost and environmental effects of spray devices are then dealt with [fr

  10. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2002-12-15

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a noncool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower the ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential building with a low-sloped roof yields average annual cooling energy savings of approximately 300 kWh/1000 ft2 [3.2 kWh/m2], average annual natural gas deficits of 4.9 therm/1000 ft2 [5.6 MJ/m2], average source energy savings of 2.6 MBTU/1000 ft2 [30 MJ/m2], and average peak power demand savings of 0. 19 kW/1000 ft2 [2.1 W/m2]. The 15-year net present value (NPV) of energy savings averages $450/1000 ft2 [$4.90/m2] with time dependent valuation (TDV), and $370/1000 ft2 [$4.00/m2] without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV + equipment savings) rises to $550/1000 ft2 [$5.90/m2] with TDV, and to $470/1000 ft2 [$5.00/m2] without TDV. Total savings range from 0.18 to 0.77 $/ft2 [1.90 to 8.30 $/m2] with TDV, and from 0.16 to 0.66 $/ft2 [1.70 to 7.10 $/m2] without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00 to 0.20 $/ft2 [0.00 to 2.20 $/m2]. Cool roofs with premiums up to $0.20/ft2 [$2.20/m2] are expected to be cost effective in climate zones 2 through 16; those with premiums not exceeding $0.18/ft2 [$1.90/m2] are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California building energy efficiency code (Title

  11. Effectiveness of multi-stage scrubbers in reducing emissions of air pollutants from pig houses

    OpenAIRE

    Zhao, Y.; Aarnink, A.J.A.; Jong, de, M.C.M.; Ogink, N.W.M.; Groot Koerkamp, P.W.G.

    2011-01-01

    Emissions of air pollutants from livestock houses may raise environmental problems and pose hazards to public health. They can be reduced by scrubbers installed at the air outlets of livestock houses. In this study, three multi-stage scrubbers were evaluated in terms of their effectiveness in reducing emissions of airborne dust, total bacteria, ammonia, and CO2 from pig houses in winter. The three multi-stage scrubbers were one double-stage scrubber (acid stage+ bio-filter), one double-stage ...

  12. Housing of Hobson's Choice

    DEFF Research Database (Denmark)

    Vestergaard, Hedvig

    2010-01-01

    This paper looks at policies implemented to improve troubled housing estates during more than two decades. Based on evaluations of implemented programmes and case studies the paper provides a basis for discussing a number of questions: • Why do we have troubled housing estates? • What...... is the definition of troubled housing estates? • Who lives on troubled housing estates? • Who owns and manages the troubled housing estates? • What have been the reasons behind improvement programmes for troubled housing estates? • What kind of improvement programmes have been implemented and with what kind...... of results? • Have improvement programmes changed the position of the estates on the local housing markets? • What are the changes in policies and results? • What are the perspectives for policy initiatives in the field of troubled housing estates?...

  13. Simulation of solar-powered absorption cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Atmaca, I.; Yigit, A. [Uludag Univ., Bursa (Turkey). Dept. of Mechanical Engineering

    2003-07-01

    With developing technology and the rapid increase in world population, the demand for energy is ever increasing. Conventional energy will not be enough to meet the continuously increasing need for energy in the future. In this case, renewable energy sources will become important. Solar energy is a very important energy source because of its advantages. Instead of a compressor system, which uses electricity, an absorption cooling system, using renewable energy and kinds of waste heat energy, may be used for cooling. In this study, a solar-powered, single stage, absorption cooling system, using a water-lithium bromide solution, is simulated. A modular computer program has been developed for the absorption system to simulate various cycle configurations and solar energy parameters for Antalya, Turkey. So, the effects of hot water inlet temperatures on the coefficient of performance (COP) and the surface area of the absorption cooling components are studied. In addition, reference temperatures which are the minimum allowable hot water inlet temperatures are determined and their effect on the fraction of the total load met by non-purchased energy (FNP) and the coefficient of performance are researched. Also, the effects of the collector type and storage tank mass are investigated in detail. (author)

  14. Impact of higher energy efficiency standards on housing affordability in Alberta

    International Nuclear Information System (INIS)

    2010-07-01

    As a result of changes to provincial and national building and energy costs, the impact of increasing energy efficiency standards on housing affordability has been questioned. Determining housing affordability is a complicated process. This report presented the results of a costing analysis completed for upgrades of EnerGuide 80 levels of energy efficiency in homes in Calgary and Edmonton, Alberta. The elements of residential construction were identified. In order to better understand the cost impact of energy efficiency upgrades on a home, pricing data was obtained. Costing elements that were examined included housing price indexes; construction material price indexes; unionized trade wages; and land value. Specifically, the report presented the new housing price index analysis using material and labour costs. An analysis of energy efficiency improvement was then presented in terms of lifecycle costs (capital costs and life cycle costing results). It was concluded that although the price of labour and materials is increasing, the value of land is the primary driver for rising house prices. The price of housing is strongly correlated to the price of land and not the price of labour or materials. In addition, moving to EnerGuide 80 levels of energy efficiency for housing in Alberta made homes more affordable for homebuyers by lowering their total monthly housing costs. 4 tabs., 3 figs., 3 appendices.

  15. Obstetric Antecedents to Body Cooling Treatment of the Newborn Infant

    Science.gov (United States)

    Nelson, David B.; Lucke, Ashley M.; McIntire, Donald D.; Sánchez, Pablo J.; Leveno, Kenneth J.; Chalak, Lina F.

    2014-01-01

    Objective Obstetric antecedents were analyzed in births where the infant received whole-body cooling for neonatal encephalopathy. Methods This retrospective cohort study included all live-born singleton infants delivered at or beyond 36 weeks gestation from October 2005 through December 2011. Infants who had received whole-body cooling identified by review of a prospective neonatal registry were compared to a control group comprising the remaining obstetric population delivered at greater than 36 weeks but not cooled. Univariable analysis was followed by a staged, stepwise selection of variables with the intent to rank significant risk factors for cooling. Results A total of 86,371 women delivered during the study period and 98 infants received whole-body cooling (1.1/1,000 livebirths). Of these 98 infants, 80 (88%) newborns had moderate encephalopathy and 10 (12%) had severe encephalopathy prior to cooling. Maternal age less than or equal to 15 years, low parity, maternal body habitus (BMI ≥ 40 kg/m2), diabetes, preeclampsia, induction, epidural analgesia, chorioamnionitis, length of labor, and mode of delivery were associated with significantly increased risk of infant cooling during univariable analysis. Catastrophic events to include umbilical cord prolapse (OR 14; 95%CI, 3–72), placental abruption (OR 17; 95%CI, 7–44), uterine rupture (OR 130; 95%CI, 11–1477) were the strongest factors associated with infant cooling after staged-stepwise logistic analysis. Conclusion A variety of intrapartum characteristics were associated with infant cooling for neonatal encephalopathy with the most powerful antecedents being umbilical cord prolapse, placental abruption, and uterine rupture. PMID:24530976

  16. Practical results of heat conservation in a housing estate scale-actions implemented by the Pradnik-Bialy-Zachod housing cooperative in Cracow

    Energy Technology Data Exchange (ETDEWEB)

    Piotrowski, L. [Pradnik-Bialy-Zachod Housing Cooperative, Cracow (Poland)

    1995-12-31

    There are 11,600,000 apartments occupied in Poland. More than 7,700,000 of these apartments are located in towns. Energy consumption for heating, ventilation and district hot water in residential housing reaches 40% of the national power balance. A portion of district heat distribution and relatively low energy efficiency is characteristic for Polish residential housing. Seventy five percent of apartments in towns are provided with central heating installations and 55% of the entire heat demand in Polish buildings is covered by district heating systems. The total installed heat power of these systems reaches 46,000 MW. The situation with regard to conservation in Polish residential housing is directly related to the legacy of central planning of the national economy and to the current phase of its re-organization to the market-oriented system. The standard value of the overall heat-transfer coefficient for external walls in Poland until 1980 was 1.16 W/m{sup 2}K; at present it is reduced to 0.55 W/m{sup 2}K. There are numerous reasons for the low energy efficiency in residential housing. These reasons are discussed.

  17. Keeping cool, staying virtuous: Social media and the composite habitus of young Muslim women in Copenhagen

    OpenAIRE

    Karen Waltorp

    2015-01-01

    This article builds on long-term anthropological fieldwork among young Muslim women in a social housing area in Copenhagen. It explores how morality, modesty, and gender- and generational relations become reconfigured in the ways in which young women use the Smartphone and social media to navigate their everyday lives. I focus on love and marriage, the imperatives of appearing cool among peers, and keeping the family’s honour intact through the display of virtuous behaviour. Building on Bourd...

  18. Digestibility and behavior of dogs housed in kennels or metabolic cages

    Directory of Open Access Journals (Sweden)

    Tabyta Tamara Sabchuk

    2012-01-01

    Full Text Available The objective of the present study was to compare the apparent digestibility coefficients of a commercial dog food, fecal consistency and behavior of dogs housed in kennels and metabolic cages. Six adult Beagle dogs were distributed in cross-over experimental design, with six replicates per treatment. Dogs were housed in two environments: metabolic cages and in masonry kennels with solarium. Dogs were fed for a five-day adaptation period, and the five following days were used for total feces collection. Dogs behavior was recorded during a 48-h period, with 10-min intervals. Apparent digestibility coefficients were not different between treatments. However, dogs housed in metabolic cages produced lower weight and more consistent feces as compared with dogs housed in kennels. Dogs spent most of the time sleeping in both housing systems; however, dogs housed in the metabolic cages slept more than those in kennels. Stress-related behaviors (barking, whimpering, stereotypies, etc were observed for no longer than 15 minutes per day, and were not different between dogs in kennels or in cages. There is no difference in food digestibility evaluated in dogs housed in metabolic cages or kennels; however, dogs kept in metabolic cages eliminate drier feces and spend more time inactive than those kept in kennels.

  19. Emergency reactor cooling device

    International Nuclear Information System (INIS)

    Arakawa, Ken.

    1993-01-01

    An emergency nuclear reactor cooling device comprises a water reservoir, emergency core cooling water pipelines having one end connected to a water feeding sparger, fire extinguishing facility pipelines, cooling water pressurizing pumps, a diesel driving machine for driving the pumps and a battery. In a water reservoir, cooling water is stored by an amount required for cooling the reactor upon emergency and for fire extinguishing, and fire extinguishing facility pipelines connecting the water reservoir and the fire extinguishing facility are in communication with the emergency core cooling water pipelines connected to the water feeding sparger by system connection pipelines. Pumps are operated by a diesel power generator to introduce cooling water from the reservoir to the emergency core cooling water pipelines. Then, even in a case where AC electric power source is entirely lost and the emergency core cooling system can not be used, the diesel driving machine is operated using an exclusive battery, thereby enabling to inject cooling water from the water reservoir to a reactor pressure vessel and a reactor container by the diesel drive pump. (N.H.)

  20. Organohalogen products from chlorination of cooling water at nuclear power stations

    International Nuclear Information System (INIS)

    Bean, R.M.

    1983-10-01

    Eight nuclear power units at seven locations in the US were studied to determine the effects of chlorine, added as a biocide, on the composition of cooling water discharge. Water, sediment and biota samples from the sites were analyzed for total organic halogen and for a variety of organohalogen compounds. Haloforms were discharged from all plants studied, at concentrations of a few μg/L (parts-per-billion). Evidence was obtained that power plants with cooling towers discharge a significant portion of the haloforms formed during chlorination to the atmosphere. A complex mixture of halogenated phenols was found in the cooling water discharges of the power units. Cooling towers can act to concentrate halogenated phenols to levels approaching those of the haloforms. Examination of samples by capillary gas chromatography/mass spectrometry did not result in identification of any significant concentrations of lipophilic base-neutral compounds that could be shown to be formed by the chlorination process. Total concentrations of lipophilic (Bioabsorbable) and volatile organohalogen material discharged ranged from about 2 to 4 μg/L. Analysis of sediment samples for organohalogen material suggests that certain chlorination products may accumulate in sediments, although no tissue bioaccumulation could be demonstrated from analysis of a limited number of samples. 58 references, 25 figures, 31 tables

  1. Thermodynamic analysis of cooling systems for nuclear power stations condenser

    International Nuclear Information System (INIS)

    Beck, A.

    1985-06-01

    This work is an attempt to concentrate on the thermodynamic theory, the engineering solution and the quantities of water needed for the operation of a wet as well as a wet/dry cooling towers coupled to a nuclear turbine condenser,. About two hundred variables are needed for the design of a condenser - cooling tower system. In order to make the solution fast and handy, a computer model was developed. The amount of water evaporation from cooling towers is a function of the climate conditions prevailing around the site. To achieve an authentic analysis, the meteorological data of the northern Negev was used. The total amount of water necessary to add to the system in a year time of operation is large and is a function of both the blow-down rate and the evaporation. First estimations show that the use of a combined system, wet/dry cooling tower, is beneficial in the northern Negev area. Such a system can reduce significantly the amount of wasted fresh water. Lack of international experience is the major problem in the acceptability of wet/dry cooling towers. The technology of a wet cooling tower using sea water is also discussed where no technical or engineering limitations were found. This work is an attempt to give some handy tools for making the choice of cooling systems for nuclear power plants easier

  2. Nordic Housing Enabler

    DEFF Research Database (Denmark)

    Helle, Tina; Brandt, Åse

    Development and reliability testing of the Nordic Housing Enabler – an instrument for accessibility assessment of the physical housing. Tina Helle & Åse Brandt University of Lund, Health Sciences, Faculty of Medicine (SE) and University College Northern Jutland, Occupational Therapy department (DK......). Danish Centre for Assistive Technology. Abstract. For decades, accessibility to the physical housing environment for people with functional limitations has been of interest politically, professionally and for the users. Guidelines and norms on accessible housing design have gradually been developed......, however, the built environment shows serious deficits when it comes to accessibility. This study addresses development of a content valid cross-Nordic version of the Housing Enabler and investigation of inter-rater reliability, when used in occupational therapy practice. The instrument was translated from...

  3. 20 CFR 654.407 - Housing.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Housing. 654.407 Section 654.407 Employees... EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.407 Housing. (a) Housing... occupants against the elements. (b) Housing shall have flooring constructed of rigid materials, smooth...

  4. Analysis and performance assessment of a multigenerational system powered by Organic Rankine Cycle for a net zero energy house

    International Nuclear Information System (INIS)

    Hassoun, Anwar; Dincer, Ibrahim

    2015-01-01

    This paper develops a new Organic Rankine Cycle (ORC) based multigenerational system to meet the demands of a net zero energy building and assesses such a system for an application to a net zero energy house in Lebanon. Solar energy is the prime source for the integrated system to achieve multigeneration to supply electricity, fresh and hot water, seasonal heating and cooling. The study starts by optimizing the power system with and without grid connection. Then, a comprehensive thermodynamic analysis through energy and exergy, and a parametric study to assess the sensitivity and improvements of the overall system are conducted. Furthermore, exergoeconomic analysis and a follow-up optimization study for optimizing the total system cost to the overall system efficiency using genetic algorithm to obtain the optimal design or a set of optimal designs (Pareto Front), are carried out. The present results show that the optimum solar energy system for a total connected load to the house of 90 kWh/day using a combination of ORC, batteries, convertor has a total net present cost of US $52,505.00 (based on the prices in 2013) with a renewable energy fraction of 1. Moreover, the optimization for the same connected load with ORC, batteries and converter configuration with grid connection results in a total net present cost of $50,868.00 (2013) with a renewable energy fraction of 0.992 with 169 kg/yr of CO 2 emissions. In addition, exergoeconomic analysis of the overall system yields a cost of $117,700.00 (2013), and the multi-objective optimization provides the overall exergetic efficiency by 14% at a total system cost increase of $10,500.00 (2013). - Highlights: • To develop a new Organic Rankine Cycle (ORC) based multigenerational system to meet the demands of a net zero energy building. • To perform a comprehensive thermodynamic analysis through energy and exergy approaches. • To apply an exergoeconomic model for exergy-based cost accounting. • To undertake

  5. Solar Living House Final Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Bradley [Univ. of Florida, Gainesville, FL (United States)

    2017-03-09

    or computing device. These systems allow for more precise calibrations of temperature/humidity/lighting to correspond with user needs and preferences, minimizing energy losses with economical night- or day-time setbacks. Solar Dehumidification System: The most significant technological innovation in the Solar Living House is the solar thermal dehumidification system. This system generates hot water through two rooftop-mounted evacuated tube solar thermal collectors. The hot water is used to continually dry a regenerative solid desiccant material, typically white silica gel. The solid desiccant is used to adsorb moisture and humidity from the air without additional mechanical cooling. This strategy allows humidity to be modulated independently of air temperature, providing greater thermal comfort and reducing the opportunity for the growth of mold spores within the house while also reducing the overall energy consumption of the HVAC system. Economic Feasibility: The team set aggressive goals for affordability, targeting a construction cost of $138,710. An independent professional cost estimator determined the overall project costs, as designed, would be $333,799, or $336.15 per square foot of finished floor area. This is more than 2.4 times the target construction cost. By comparison, the average construction cost for a home in the United States in 2015 was $289,415, or $103.29 per square foot of finished floor area. Following work on the Solar Living House, team leaders incorporated many of its objectives into a net-zero energy home on a site in Gainesville, Florida. This site-built home avoided many of the constraints and complications of modular construction necessitated by the Solar Decathlon, allowing it to be built for a much more modest budget. This two-bedroom two bath 1,800 square foot home was constructed for $135.39 per square foot, including active photovoltaic solar systems, careful attention to continuous air barriers, increased insulation levels, and

  6. Effect of water treatment on the comparative costs of evaporative and dry cooled power plants

    International Nuclear Information System (INIS)

    Gold, H.; Goldstein, D.J.; Yung, D.

    1976-07-01

    The report presents the results of a study on the relative cost of energy from a nominal 1000 Mwe nuclear steam electric generating plant using either dry or evaporative cooling at four sites in the United States: Rochester, New York; Sheridan, Wyoming; Gallup, New Mexico and Dallas, Texas. Previous studies have shown that because of lower efficiencies the total annual evaluated costs for dry cooling systems exceeds the total annual evaluated costs of evaporative cooling systems, not including the cost of water. The cost of water comprises the cost of supplying the makeup water, the cost of treatment of the makeup and/or the circulating water in the tower, and the cost of treatment and disposal of the blowdown in an environmentally acceptable manner. The purpose of the study is to show the effect of water costs on the comparative costs of dry and evaporative cooled towers

  7. The role of outsourcing in the project house - mining house relationship

    OpenAIRE

    2008-01-01

    M.Phil. The relationship between the Mining House / Owner and Project House can be spectacularly successful for both partners (and has resulted in the emergence of a few successful new project houses and plant operation companies all over the world), but can also be disastrous for both parties, if managed incorrectly. The main requirement for a successful relationship between a Mining- and Project House is that there must be something in it for both parties. This is not only measured in cu...

  8. Cooling rate effects on structure of amorphous graphene

    International Nuclear Information System (INIS)

    Van Hoang, Vo

    2015-01-01

    Simple monatomic amorphous 2D models with Honeycomb structure are obtained from 2D simple monatomic liquids with Honeycomb interaction potential (Rechtsman et al., Phys. Rev. Lett. 95, 228301 (2005)) via molecular dynamics (MD) simulations. Models are observed by cooling from the melt at various cooling rates. Temperature dependence of thermodynamic and structural properties including total energy, mean ring size, mean coordination number is studied in order to show evolution of structure and thermodynamics upon cooling from the melt. Structural properties of the amorphous Honeycomb structures are studied via radial distribution function (RDF), coordination number and ring distributions together with 2D visualization of the atomic configurations. Amorphous Honeycomb structures contain a large amount of structural defects including new ones which have not been previously reported yet. Cooling rate dependence of structural properties of the obtained amorphous Honeycomb structures is analyzed. Although amorphous graphene has been proposed theoretically and/or recently obtained by the experiments, our understanding of structural properties of the system is still poor. Therefore, our simulations highlight the situation and give deeper understanding of structure and thermodynamics of the glassy state of this novel 2D material

  9. Cooled-Spool Piston Compressor

    Science.gov (United States)

    Morris, Brian G.

    1994-01-01

    Proposed cooled-spool piston compressor driven by hydraulic power and features internal cooling of piston by flowing hydraulic fluid to limit temperature of compressed gas. Provides sufficient cooling for higher compression ratios or reactive gases. Unlike conventional piston compressors, all parts of compressed gas lie at all times within relatively short distance of cooled surface so that gas cooled more effectively.

  10. Cooling towers

    International Nuclear Information System (INIS)

    Korik, L.; Burger, R.

    1992-01-01

    What is the effect of 0.6C (1F) temperature rise across turbines, compressors, or evaporators? Enthalpy charts indicate for every 0.6C (1F) hotter water off the cooling tower will require an additional 2 1/2% more energy cost. Therefore, running 2.2C (4F) warmer due to substandard cooling towers could result in a 10% penalty for overcoming high heads and temperatures. If it costs $1,250,000.00 a year to operate the system, $125,000.00 is the energy penalty for hotter water. This paper investigates extra fuel costs involved in maintaining design electric production with cooling water 0.6C (1F) to 3C (5.5F) hotter than design. If design KWH cannot be maintained, paper will calculate dollar loss of saleable electricity. The presentation will conclude with examining the main causes of deficient cold water production. State-of-the-art upgrading and methodology available to retrofit existing cooling towers to optimize lower cooling water temperatures will be discussed

  11. Water cooling coil

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, S; Ito, Y; Kazawa, Y

    1975-02-05

    Object: To provide a water cooling coil in a toroidal nuclear fusion device, in which coil is formed into a small-size in section so as not to increase dimensions, weight or the like of machineries including the coil. Structure: A conductor arranged as an outermost layer of a multiple-wind water cooling coil comprises a hollow conductor, which is directly cooled by fluid, and as a consequence, a solid conductor disposed interiorly thereof is cooled indirectly.

  12. Effect of closed loop cooling water transit time on containment cooling

    International Nuclear Information System (INIS)

    Smith, R.P.; Vossahlik, J.E.; Goodwin, E.F.

    1996-01-01

    Long term containment cooling analyses in nuclear plant systems are usually conducted assuming a quasi steady-state process, that is, a steady state evaluation of the cooling system is completed for each calculational step. In reality, fluid transport in the system, and heat addition to system components may affect the heat removal rate of the system. Transient effects occurring during system startup may affect the maximum temperatures experienced in the system. It is important to ensure that such transient effects do not affect operation of the system (e.g., cause a high temperature trip). To evaluate the effect of fluid transit delays, a closed loop cooling water system model has been developed that incorporates the fluid transport times when determining the closed loop cooling system performance. This paper describes the closed loop cooling system model as implemented in the CONTEMPT-LT/028 code. The evaluation of the transient temperature response of the closed loop cooling system using the model is described. The paper also describes the effect of fluid transit time on the overall containment cooling performance

  13. TECHNIQUES FOR RECONSTRUCTION OF THE PRESERVED HOUSING STOCK

    Directory of Open Access Journals (Sweden)

    Kustikova Yuliya Olegovna

    2017-10-01

    Full Text Available Nowadays in Russian cities a significant part of the housing stock in areas of existing buildings has a high level of physical and moral deterioration, indicators of infrastructure elements do not meet the current and future requirements. Reconstruction of residential buildings is one of the important directions in solving the housing problem. This will allow us to not only extend the life cycle but also significantly improve the quality of housing, eliminate a communal settlement, provide the houses with modern engineering equipment, improve architectural expressiveness of buildings and increase their energy efficiency. For buildings of different construction periods an individual approach is required in the development of methods and technologies of reconstruction. At the same time, the process should take place not in a separate building but in a group of buildings, neighborhood or district. This makes it possible to undertake a comprehensive assessment of the urban development situation and make the most rational decisions to meet modern conditions, and provide logical connection between various architectural trends. At the same time, there are possibilities for compaction and decompaction of buildings, the rational use of inter-district, underground space and communication systems. Moscow region is a large region, which occupies an area of 46 thousand square kilometers. The region includes more than 38 municipalities (municipal districts, urban and rural settlements. The region’s population is more than 7 million people. Moscow oblast has a central location in the Russian Federation and a close relationship with the capital. This relationship with Moscow is manifested through common social, scientific, industrial, transport links, environmental protection problems, labor resources. In 2016 the total area of the housing stock in Moscow region was about 220 million sq. m. The total area of dilapidated and emergency housing stock is just

  14. Potential implementation of light steel housing system for affordable housing project in Malaysia

    Science.gov (United States)

    Saikah, M.; Kasim, N.; Zainal, R.; Sarpin, N.; Rahim, M. H. I. A.

    2017-11-01

    An unparalleled number between housing demand and housing supply in Malaysia has increased the housing prices, which gives consequences to the homeownership issue. One way to reduce the housing price is by faster increase the number of affordable housing, but the construction sector faces difficulties in delivering as expected number by using conventional and current industrialised building system (IBS) due to the issue related high project cost, time and labour. Therefore, light steel housing (LSH) system as one of another type of IBS method can be utilised in housing construction project. This method can replace the conventional method that was currently used in the construction of affordable housing project. The objectives of this study are to identify the potential of LSH and influencing factors of system implementation. This is an initial stage to review the previous study related to LSH implementation in developed and developing countries. The previous study will be analysed regarding advantages and disadvantages of LSH and factors that influence the implementation of the system. Based on the literature review it is expected to define the potential and influencing factors of the LSH system. The findings are meaningful in framing and enhance construction housing method of an affordable housing project in Malaysia.

  15. Assisted Housing - Housing Choice Vouchers by Tract - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The U.S. Department of Housing and Urban Development’s (HUD) Housing Choice Voucher Program (HCVP) is the federal government's major program for assisting very...

  16. Theoretical analysis of the performance of different cooling strategies with the concept of cool exergy

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    The whole chains of exergy flows for different cooling systems were compared. The effects of cooling demand (internal vs. external solar shading), space cooling method (floor cooling vs. air cooling with ventilation system), and the availability of a nearby natural heat sink (intake air for the v......The whole chains of exergy flows for different cooling systems were compared. The effects of cooling demand (internal vs. external solar shading), space cooling method (floor cooling vs. air cooling with ventilation system), and the availability of a nearby natural heat sink (intake air...... for the ventilation system being outdoor air vs. air from the crawl-space, and air-to-water heat pump vs. ground heat exchanger as cooling source) on system exergy performance were investigated. It is crucial to minimize the cooling demand because it is possible to use a wide range of heat sinks (ground, lake, sea......-water, etc.) and indoor terminal units, only with a minimized demand. The water-based floor cooling system performed better than the air-based cooling system; when an air-to-water heat pump was used as the cooling source, the required exergy input was 28% smaller for the floor cooling system. The auxiliary...

  17. The cooling of particle beams

    International Nuclear Information System (INIS)

    Sessler, A.M.

    1994-10-01

    A review is given of the various methods which can be employed for cooling particle beams. These methods include radiation damping, stimulated radiation damping, ionization cooling, stochastic cooling, electron cooling, laser cooling, and laser cooling with beam coupling. Laser Cooling has provided beams of the lowest temperatures, namely 1 mK, but only for ions and only for the longitudinal temperature. Recent theoretical work has suggested how laser cooling, with the coupling of beam motion, can be used to reduce the ion beam temperature in all three directions. The majority of this paper is devoted to describing laser cooling and laser cooling with beam coupling

  18. Narrow-line laser cooling by adiabatic transfer

    Science.gov (United States)

    Norcia, Matthew A.; Cline, Julia R. K.; Bartolotta, John P.; Holland, Murray J.; Thompson, James K.

    2018-02-01

    We propose and demonstrate a novel laser cooling mechanism applicable to particles with narrow-linewidth optical transitions. By sweeping the frequency of counter-propagating laser beams in a sawtooth manner, we cause adiabatic transfer back and forth between the ground state and a long-lived optically excited state. The time-ordering of these adiabatic transfers is determined by Doppler shifts, which ensures that the associated photon recoils are in the opposite direction to the particle’s motion. This ultimately leads to a robust cooling mechanism capable of exerting large forces via a weak transition and with reduced reliance on spontaneous emission. We present a simple intuitive model for the resulting frictional force, and directly demonstrate its efficacy for increasing the total phase-space density of an atomic ensemble. We rely on both simulation and experimental studies using the 7.5 kHz linewidth 1S0 to 3P1 transition in 88Sr. The reduced reliance on spontaneous emission may allow this adiabatic sweep method to be a useful tool for cooling particles that lack closed cycling transitions, such as molecules.

  19. Corrosion characteristics of an aqueous self-cooled fusion blanket

    International Nuclear Information System (INIS)

    Bogaerts, W.F.; Embrechts, M.J.; Steiner, D.; Deutsch, L.; Jackson, D.

    1986-01-01

    A novel aqueous self-cooled blanket concept (ASCB) has recently been proposed. This blanket concept, as applied to a MARS-like tandem mirror reactor, consists of disks of spiraling tubes of Zircaloy-4 housed in a structural container of vanadium alloy (V-15 Ti-5 Cr). The Zircaloy tubes are cooled by a mixture of light and heavy water with 9 g of LiOH per 100 cm 3 of water dissolved in the coolant. A major issue for the feasibility of the integrated blanket coil concept is the chemical compatibility of the coolant and Zircaloy. Initial corrosion tests have been undertaken in order to resolve this question. Results clearly show that successful alloy heats can be prepared, for which corrosion problems will probably not be the limiting factor of the ASCB design concept. As is quite well known from fission engineering studies, small variations in the alloy compositions or in the metallurgical structure may, however, be able to cause significant alterations in the oxidation or corrosion rates. Further tests will be necessary to resolve the remaining uncertainties and to determine the behavior of successful alloy heats in the presence of trace impurities in order to address the sensitivity to localized corrosion phenomena such as pitting, stress corrosion cracking, and intergranular attack

  20. On the influence of the alternation of two different cooling systems on dairy cow daily activities

    Directory of Open Access Journals (Sweden)

    Simona M.C. Porto

    2017-02-01

    Full Text Available Among the causes that influence cow welfare, heat stress induced by microclimatic conditions is one of the most relevant and many studies have investigated the efficacy of different cooling systems on animal health status. Nevertheless, the direct influence of the cooling systems on possible modifications of dairy cow behaviour has been addressed in a few studies and the related results were affected by the presence of a paddock, which gave a refuge from hot temperature. Since an alteration of the daily time budget spent by dairy cows in their usual activities can be associated with changes in their health status, this study investigated the effects of the alternation of two different cooling systems on lying, standing, and feeding behaviour of a group of dairy cows bred in a free-stall dairy house where animals had no access to a paddock. The barn was equipped with a fogging system associated with forced ventilation installed in the resting area and a sprinkler system associated with forced ventilation installed in the feeding area. The two systems were activated alternately. The results demonstrated that the management of the two cooling systems affected the analysed behaviours. Though the activation of the cooling system installed in the resting area encouraged the decubitus of animals in the stalls, the activation of that one of the feeding alley could not be able to influence the standing behaviour and had only a moderate positive influence on the feeding activity.

  1. A study of the passive cooling potential in simulated building in Latvian climate conditions

    Science.gov (United States)

    Prozuments, A.; Vanags, I.; Borodinecs, A.; Millers, R.; Tumanova, K.

    2017-10-01

    In this paper authors point out that overheating in buildings during summer season is a major problem in moderate and cold climates, not only in warm climate zones. Mostly caused by solar heat gains, especially in buildings with large glazed areas overheating is a common problem in recently constructed low-energy buildings. At the same time, comfort demands are increasing. While heating loads can be decreased by improving the insulation of the building envelope, cooling loads are also affecting total energy demand. Passive cooling solutions allow reduction of heat gains, and thus reducing the cooling loads. There is a significant night cooling potential with low temperatures at night during summer in moderate and cold climates. Night cooling is based on cooling of buildings thermal mass during the night and heat accumulation during the day. This approach allows to provide thermal comfort, reducing cooling loads during the day. Authors investigate thermal comfort requirements and causes for discomfort. Passive cooling methods are described. The simulation modeling is carried out to analyze impact of constructions and building orientation on energy consumption for cooling using the IDA-ICE software. Main criteria for simulation analysis are energy consumption for cooling and thermal comfort.

  2. Spatial Analysis on Future Housing Markets: Economic Development and Housing Implications

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2014-01-01

    Full Text Available A coupled projection method combining formal modelling and other statistical techniques was developed to delineate the relationship between economic and social drivers for net new housing allocations. Using the example of employment growth in Tyne and Wear, UK, until 2016, the empirical analysis yields housing projections at the macro- and microspatial levels (e.g., region to subregion to elected ward levels. The results have important implications for the strategic planning of locations for housing and employment, demonstrating both intuitively and quantitatively how local economic developments affect housing demand.

  3. Emergency cooling system for a liquid metal cooled reactor

    International Nuclear Information System (INIS)

    Murata, Ryoichi; Fujiwara, Toshikatsu.

    1980-01-01

    Purpose: To suitably cool liquid metal as coolant in emergency in a liquid metal cooled reactor by providing a detector for the pressure loss of the liquid metal passing through a cooling device in a loop in which the liquid metal is flowed and communicating the detector with a coolant flow regulator. Constitution: A nuclear reactor is stopped in nuclear reaction by control element or the like in emergency. If decay heat is continuously generated for a while and secondary coolant is insufficiently cooled with water or steam flowed through a steam and water loop, a cooler is started. That is, low temperature air is supplied by a blower through an inlet damper to the cooler to cool the secondary coolant flowed into the cooler through a bypass pipe so as to finally safely stop an entire plant. Since the liquid metal is altered in its physical properties by the temperature at this time, it is detected to regulate the opening of the valve of the damper according to the detected value. (Sekiya, K.)

  4. Social Housing Provision in Copenhagen

    DEFF Research Database (Denmark)

    Tsenkova, Sasha; Vestergaard, Hedvig

    -profit housing providers, and a wide range of fiscal and regulatory instruments enhancing the competitive performance of the social housing sector. The research analyses recent housing policy measures and their impact on new social housing provision in Copenhagen. The emphasis is on the mix of housing policy......The paper provides an overview of trends and processes of change affecting new social housing provision in Denmark with a focus on Copenhagen. The local responses are reviewed within the context of changes to the unitary national housing system that functions with a robust range of private and non...... instruments implemented in three major policy domains-fiscal, financial and regulatory-to promote the production of new social housing. The system of new social housing provision is examined as a dynamic process of interaction between public and private institutions defining housing policy outcomes...

  5. Obstetric antecedents to body-cooling treatment of the newborn infant.

    Science.gov (United States)

    Nelson, David B; Lucke, Ashley M; McIntire, Donald D; Sánchez, Pablo J; Leveno, Kenneth J; Chalak, Lina F

    2014-08-01

    Obstetric antecedents were analyzed in births in which the infant received whole-body cooling for neonatal encephalopathy. This retrospective cohort study included all live-born singleton infants delivered at or beyond 36 weeks' gestation from October 2005 through December 2011. Infants who had received whole-body cooling identified by review of a prospective neonatal registry were compared with a control group comprising the remaining obstetric population delivered at greater than 36 weeks but not cooled. Univariable analysis was followed up by a staged, stepwise selection of variables with the intent to rank significant risk factors for cooling. A total of 86,371 women delivered during the study period and 98 infants received whole-body cooling (1.1 per 1000 live births). Of these 98 infants, 80 newborns (88%) had moderate encephalopathy and 10 (12%) had severe encephalopathy prior to cooling. Maternal age of 15 years or younger, low parity, maternal body habitus (body mass index of ≥40 kg/m(2)), diabetes, preeclampsia, induction, epidural analgesia, chorioamnionitis, length of labor, and mode of delivery were associated with significantly increased risk of infant cooling during a univariable analysis. Catastrophic events to include umbilical cord prolapse (odds ratio [OR], 14; 95% confidence interval [CI], 3-72), placental abruption (OR, 17; 95% CI, 7-44), uterine rupture (OR, 130; 95% CI, 11-1477) were the strongest factors associated with infant cooling after staged-stepwise logistic analysis. A variety of intrapartum characteristics were associated with infant cooling for neonatal encephalopathy, with the most powerful antecedents being umbilical cord prolapse, placental abruption, and uterine rupture. Copyright © 2014 Mosby, Inc. All rights reserved.

  6. Hybrid radiator cooling system

    Science.gov (United States)

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  7. Meltdown reactor core cooling facility

    International Nuclear Information System (INIS)

    Matsuoka, Tsuyoshi.

    1992-01-01

    The meltdown reactor core cooling facility comprises a meltdown reactor core cooling tank, a cooling water storage tank situates at a position higher than the meltdown reactor core cooling tank, an upper pipeline connecting the upper portions of the both of the tanks and a lower pipeline connecting the lower portions of them. Upon occurrence of reactor core meltdown, a high temperature meltdown reactor core is dropped on the cooling tank to partially melt the tank and form a hole, from which cooling water is flown out. Since the water source of the cooling water is the cooling water storage tank, a great amount of cooling water is further dropped and supplied and the reactor core is submerged and cooled by natural convection for a long period of time. Further, when the lump of the meltdown reactor core is small and the perforated hole of the meltdown reactor cooling tank is small, cooling water is boiled by the high temperature lump intruding into the meltdown reactor core cooling tank and blown out from the upper pipeline to the cooling water storage tank to supply cooling water from the lower pipeline to the meltdown reactor core cooling tank. Since it is constituted only with simple static facilities, the facility can be simplified to attain improvement of reliability. (N.H.)

  8. Impacts of the Weatherization Assistance Program in Fuel-Oil Heated Houses

    Energy Technology Data Exchange (ETDEWEB)

    Levins, W.P.

    1994-01-01

    In 1990, the U.S. Department of Energy (DOE) initiated a national evaluation of its low-income Weatherization Assistance Program. This report, which is one of five parts of that evaluation, evaluates the energy savings and cost-effectiveness of the Program as it had been applied to single-family houses heated primarily by fuel-oil. The study was based upon a representative sample (41 local weatherization agencies, 222 weatherized and 115 control houses) from the nine northeastern states during 1991 and 1992 program years. Dwelling-specific and agency-level data on measures installed, costs, and service delivery procedures were collected from the sampled agencies. Space-heating fuel-oil consumption, indoor temperature, and outdoor temperature were monitored at each house. Dwelling characteristics, air-leakage measurements, space-heating system steady-state efficiency measurements, safety inspections, and occupant questionnaires were also collected or performed at each monitored house. We estimate that the Program weatherized a total of 23,400 single-family fuel-oil heated houses in the nine northeastern states during program years 1991 and 1992. Annual fuel-oil savings were calculated using regression techniques to normalize the savings to standard weather conditions. For the northeast region, annual net fuel-oil savings averaged 160 gallons per house, or 17.7% of pre-weatherization consumption. Although indoor temperatures changed in individual houses following weatherization, there was no average change and no significant difference as compared to the control houses; thus, there was no overall indoor temperature takeback effect influencing fuel-oil savings. The weatherization work was performed cost effectively in these houses from the Program perspective, which included both installation costs and overhead and management costs but did not include non-energy benefits (such as employment and environmental). Total average costs were $1819 per house ($1192 for

  9. Energy Performance of a Light Wood-Timber Structured House in the Severely Cold Region of China

    Directory of Open Access Journals (Sweden)

    Meng Zhen

    2018-05-01

    Full Text Available The purpose of the study was to determine the energy performance of a timber structured house built in Harbin, a severely cold region of China. The research team conducted a field test on the house that lasted three months (15 January–15 April 2008. The test included the winter heating energy consumption, average indoor temperature and relative humidity, building heat storage capacity, heat transfer coefficient of the wall, total air volume of air-conditioning system, etc. The test results showed that the total heating was calculated to be 73,240.59 MJ in winter. Thermal imaging tests were carried out on the house and found no obvious thermal defects such as thermal bridges. In conclusion, the timber structured house has a good level of building energy conservation and would provide a good exemplary for green building design and construction in similar severely cold regions in the world.

  10. Development of a total reflection X-ray fluorescence spectrometer for ...

    Indian Academy of Sciences (India)

    Unknown

    design and use of a peltier cooled solid state detector for energy dispersive detection. Alignment and ... X-ray beam at a glancing angle less than the critical angle at which total ... materials is < 1 so that external total reflection takes place at an ...

  11. Use of artificial intelligence to analyze clinical database reduces workload on surgical house staff.

    Science.gov (United States)

    Grossi, E A; Steinberg, B M; LeBoutillier, M; Coppa, G F; Roses, D F

    1994-08-01

    The current quantity and diversity of hospital clinical, laboratory, and pharmacy records have resulted in a glut of information, which can be overwhelming to house staff. This study was performed to measure the impact of artificial intelligence analysis of such data on the junior surgical house staff's workload, time for direct patient care, and quality of life. A personal computer was interfaced with the hospital computerized patient data system. Artificial intelligence algorithms were applied to retrieve and condense laboratory values, microbiology reports, and medication orders. Unusual laboratory tests were reported without artificial intelligence filtering. A survey of 23 junior house staff showed a requirement for a total of 30.75 man-hours per day, an average of 184.5 minutes per service twice a day for five surgical services each with an average of 40.7 patients, to manually produce a report in contrast to a total of 3.4 man-hours, an average of 20.5 minutes on the same basis (88.9% reduction, p medical practice has created an explosion of information, which is a burden for surgical house staff. Artificial intelligence preprocessing of the hospital database information focuses attention, eliminates superfluous data, and significantly reduces surgical house staff clerical work, allowing more time for education, research, and patient care.

  12. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  13. A development and integration analysis of commercial and in-house control subsystems

    International Nuclear Information System (INIS)

    Moore, D.M.; Dalesio, L.R.

    1998-01-01

    The acquisition and integration of commercial automation and control subsystems in physics research is becoming more common. It is presumed these systems present lower risk and less cost. This paper studies four subsystems used in the Accelerator Production of Tritium (APT) Low Energy Demonstration Accelerator (LEDA) at the Los Alamos National Laboratory (LANL). The radio frequency quadrupole (RFQ) resonance-control cooling subsystem (RCCS), the high-power RF subsystem and the RFQ vacuum subsystem were outsourced; the low-level RF (LLRF) subsystem was developed in-house. Based on the authors experience a careful evaluation of the costs and risks in acquisition, implementation, integration, and maintenance associated with these approaches is given

  14. Energy efficient hotspot-targeted embedded liquid cooling of electronics

    International Nuclear Information System (INIS)

    Sharma, Chander Shekhar; Tiwari, Manish K.; Zimmermann, Severin; Brunschwiler, Thomas; Schlottig, Gerd; Michel, Bruno; Poulikakos, Dimos

    2015-01-01

    Highlights: • We present a novel concept for hotspot-targeted, energy efficient ELC for electronic chips. • Microchannel throttling zones distribute flow optimally without any external control. • Design is optimized for highly non-uniform multicore chip heat flux maps. • Optimized design minimizes chip temperature non-uniformity. • This is achieved with pumping power consumption less than 1% of total chip power. - Abstract: Large data centers today already account for nearly 1.31% of total electricity consumption with cooling responsible for roughly 33% of that energy consumption. This energy intensive cooling problem is exacerbated by the presence of hotspots in multicore microprocessors due to excess coolant flow requirement for thermal management. Here we present a novel liquid-cooling concept, for targeted, energy efficient cooling of hotspots through passively optimized microchannel structures etched into the backside of a chip (embedded liquid cooling or ELC architecture). We adopt an experimentally validated and computationally efficient modeling approach to predict the performance of our hotspot-targeted ELC design. The design is optimized for exemplar non-uniform chip power maps using Response Surface Methodology (RSM). For industrially acceptable limits of approximately 0.4 bar (40 kPa) on pressure drop and one percent of total chip power on pumping power, the optimized designs are computationally evaluated against a base, standard ELC design with uniform channel widths and uniform flow distribution. For an average steady-state heat flux of 150 W/cm 2 in core areas (hotspots) and 20 W/cm 2 over remaining chip area (background), the optimized design reduces the maximum chip temperature non-uniformity by 61% to 3.7 °C. For a higher average, steady-state hotspot heat flux of 300 W/cm 2 , the maximum temperature non-uniformity is reduced by 54% to 8.7 °C. It is shown that the base design requires a prohibitively high level of pumping power (about

  15. Do housing regimes matter? : Assessing the concept of housing regimes through configurations of housing outcomes

    NARCIS (Netherlands)

    Dewilde, C.L.

    2017-01-01

    Based on a conceptualisation of de-commodification as the right to decent and affordable housing, we assessed to what extent this right is realised for low-to-moderate-income owners and renters across Western European housing regimes in 1995 and 2012. If differences in the social production of

  16. Cooled Water Production System,

    Science.gov (United States)

    The invention refers to the field of air conditioning and regards an apparatus for obtaining cooled water . The purpose of the invention is to develop...such a system for obtaining cooled water which would permit the maximum use of the cooling effect of the water -cooling tower.

  17. The study on the evaporation cooling efficiency and effectiveness of cooling tower of film type

    International Nuclear Information System (INIS)

    Li Yingjian; You Xinkui; Qiu Qi; Li Jiezhi

    2011-01-01

    Based on heat and mass transport mechanism of film type cooling, which was combined with an on-site test on counter flow film type cooling tower, a mathematical model on the evaporation and cooling efficiency and effectiveness has been developed. Under typical climatic conditions, air conditioning load and the operating condition, the mass and heat balances have been calculated for the air and the cooling water including the volume of evaporative cooling water. Changing rule has been measured and calculated between coefficient of performance (COP) and chiller load. The influences of air and cooling water parameters on the evaporative cooling efficiency were analyzed in cooling tower restrained by latent heat evaporative cooling, and detailed derivation and computation revealed that both the evaporative cooling efficiency and effectiveness of cooling tower are the same characteristics parameters of the thermal performance of a cooling tower under identical assumptions.

  18. 38 CFR 18.445 - Housing.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Housing. 18.445 Section....445 Housing. (a) Housing provided by a recipient. A recipient that provides housing to its nonhandicapped students shall provide comparable, convenient, and accessible housing to qualified handicapped...

  19. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state-of-the-art of ventil......This report, by venticool, summarises the outcome of the work of the initial working phase of IEA ECB Annex 62 Ventilative Cooling and is based on the findings in the participating countries. It presents a summary of the first official Annex 62 report that describes the state......-of-the-art of ventilative cooling potentials and limitations, its consideration in current energy performance regulations, available building components and control strategies and analysis methods and tools. In addition, the report provides twenty six examples of operational buildings using ventilative cooling ranging from...

  20. Cooling tower make-up water processing for nuclear power plants: a comparison

    Energy Technology Data Exchange (ETDEWEB)

    Andres, O; Flunkert, F; Hampel, G; Schiffers, A [Rheinisch-Westfaelisches Elektrizitaetswerk A.G., Essen (Germany, F.R.)

    1977-01-01

    In water-cooled nuclear power plants, 1 to 2% of the total investment costs go to cooling tower make-up water processing. The crude water taken from rivers or stationary waters for cooling must be sufficiently purified regarding its content of solids, carbonate hardness and corrosive components so as to guarantee an operation free of disturbances. At the same time, the processing methods must be selected for operational-economic reasons in such a manner that waste water and waste problems are kept small regarding environmental protection. The various parameters described have a decisive influence on the processing methods of the crude water, individual processes (filtration, sedimentation, decarbonization) are described, circuit possibilities for cooling water systems are compared and the various processes are analyzed and compared with regard to profitableness and environmental compatability.

  1. Tarp-Assisted Cooling as a Method of Whole-Body Cooling in Hyperthermic Individuals.

    Science.gov (United States)

    Hosokawa, Yuri; Adams, William M; Belval, Luke N; Vandermark, Lesley W; Casa, Douglas J

    2017-03-01

    We investigated the efficacy of tarp-assisted cooling as a body cooling modality. Participants exercised on a motorized treadmill in hot conditions (ambient temperature 39.5°C [103.1°F], SD 3.1°C [5.58°F]; relative humidity 38.1% [SD 6.7%]) until they reached exercise-induced hyperthermia. After exercise, participants were cooled with either partial immersion using a tarp-assisted cooling method (water temperature 9.20°C [48.56°F], SD 2.81°C [5.06°F]) or passive cooling in a climatic chamber. There were no differences in exercise duration (mean difference=0.10 minutes; 95% CI -5.98 to 6.17 minutes or end exercise rectal temperature (mean difference=0.10°C [0.18°F]; 95% CI -0.05°C to 0.25°C [-0.09°F to 0.45°F] between tarp-assisted cooling (48.47 minutes [SD 8.27 minutes]; rectal temperature 39.73°C [103.51°F], SD 0.27°C [0.49°F]) and passive cooling (48.37 minutes [SD 7.10 minutes]; 39.63°C [103.33°F], SD 0.40°C [0.72°F]). Cooling time to rectal temperature 38.25°C (100.85°F) was significantly faster in tarp-assisted cooling (10.30 minutes [SD 1.33 minutes]) than passive cooling (42.78 [SD 5.87 minutes]). Cooling rates for tarp-assisted cooling and passive cooling were 0.17°C/min (0.31°F/min), SD 0.07°C/min (0.13°F/min) and 0.04°C/min (0.07°F/min), SD 0.01°C/min (0.02°F/min), respectively (mean difference=0.13°C [0.23°F]; 95% CI 0.09°C to 0.17°C [0.16°F to 0.31°F]. No sex differences were observed in tarp-assisted cooling rates (men 0.17°C/min [0.31°F/min], SD 0.07°C/min [0.13°F/min]; women 0.16°C/min [0.29°F/min], SD 0.07°C/min [0.13°F/min]; mean difference=0.02°C/min [0.04°F/min]; 95% CI -0.06°C/min to 0.10°C/min [-0.11°F/min to 0.18°F/min]). Women (0.04°C/min [0.07°F/min], SD 0.01°C/min [0.02°F/min]) had greater cooling rates than men (0.03°C/min [0.05°F/min], SD 0.01°C/min [0.02°F/min]) in passive cooling, with negligible clinical effect (mean difference=0.01°C/min [0.02°F/min]; 95% CI 0.001

  2. Elimination behavior of shelter dogs housed in double compartment kennels.

    Directory of Open Access Journals (Sweden)

    Denae Wagner

    Full Text Available For animals in confinement housing the housing structure has tremendous potential to impact well being. Dogs in animal shelters are often housed in one of two types of confinement housing - single kennels and rooms or double compartment kennels and rooms most often separated by a guillotine door. This study examines the effect of housing on the location of elimination behavior in dogs housed in double compartment kennels were the majority of the dogs were walked daily. One side of the kennel contained the food, water and bed and the other side was empty and available except during cleaning time. Location of urination and defecation was observed daily for 579 dogs housed in indoor double compartment kennels for a total of 4440 days of observation. There were 1856 days (41.9% when no elimination was noted in the kennel. Feces, urine or both were observed in the kennel on 2584 days (58.1%. When elimination occurred in the kennel the probability of fecal elimination on the opposite side of the bed/food/water was 72.5% (95% CI 69.05% to 75.69%. The probability of urination on the opposite side of the bed/food/water was 77.4% (95% CI 74.33% to 80.07%. This study demonstrates the strong preference of dogs to eliminate away from the area where they eat, drink and sleep. Double compartment housing not only allows this - it allows staff the ability to provide safe, efficient, humane daily care and confers the added benefits of reducing risks for disease transmission for the individual dog as well as the population.

  3. Labour Mobility and Housing: The Impact of Housing Tenure and Housing Affordability on Labour Migration in the Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Lux, Martin; Sunega, Petr

    2012-01-01

    Roč. 49, č. 3 (2012), s. 489-504 ISSN 0042-0980 R&D Projects: GA ČR GA403/09/1915 Institutional research plan: CEZ:AV0Z70280505 Keywords : housing * housing policy * housing tenure Subject RIV: AO - Sociology, Demography Impact factor: 1.493, year: 2012 http://usj.sagepub.com/content/early/2011/05/20/0042098011405693

  4. Heat Driven Cooling in District Energy Systems; Vaermedriven Kyla

    Energy Technology Data Exchange (ETDEWEB)

    Rydstrand, Magnus; Martin, Viktoria; Westermark, Mats [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2004-07-01

    This report is reviewing different heat driven technologies for the production of cooling. It is shown that the supply of cooling gives the highest fuel utilization if heat from CHP production is used for the production of cooling instead of maximizing the electricity output in a condensing plant. High fuel utilization is reached since the direct production of cooling from heat is a thermodynamic shortcut as compared to the production of electricity as an intermediate product before cooling is produced. At direct production of cooling from heat it is possible to obtain 70 percent of the obtainable cooling of an ideal process. If electricity is produced from heat, 70 percent electricity could be obtained as compared to an ideal process. If this electricity would be used for the production of cooling 70 percent of the obtainable cooling in an ideal process would the result. The total production of cooling from heat with electricity as an intermediate product would therefore give 50 percent cooling as compared to an ideal process. Hence, heat driven cooling will give more cooling for a given fuel input. In the review of the different heat driven cooling options it was found that there are many alternatives suitable for different applications. Absorption cooling is suitable for water distributed cooling if the latent cooling load is low. Desiccant cooling is believed to have a large market in climates (applications) with high latent cooling loads. In the energy efficiency evaluation it is found that the highest fuel utilization is given for a central production of electricity using either district heating or district cooling as the energy carrier to supply cooling. In fact the potential of district heating as the energy carrier is thought to be the largest in large cities with humid climates. Further it is found that the chiller heat sink can contribute significantly to the cost in many applications, especially if water and/or electricity consumption are issues with

  5. Process fluid cooling system

    International Nuclear Information System (INIS)

    Farquhar, N.G.; Schwab, J.A.

    1977-01-01

    A system of heat exchangers is disclosed for cooling process fluids. The system is particularly applicable to cooling steam generator blowdown fluid in a nuclear plant prior to chemical purification of the fluid in which it minimizes the potential of boiling of the plant cooling water which cools the blowdown fluid

  6. Revisiting the Cooling Flow Problem in Galaxies, Groups, and Clusters of Galaxies

    Science.gov (United States)

    McDonald, M.; Gaspari, M.; McNamara, B. R.; Tremblay, G. R.

    2018-05-01

    We present a study of 107 galaxies, groups, and clusters spanning ∼3 orders of magnitude in mass, ∼5 orders of magnitude in central galaxy star formation rate (SFR), ∼4 orders of magnitude in the classical cooling rate ({\\dot{M}}cool}\\equiv {M}gas}(rsample, we measure the ICM cooling rate, {\\dot{M}}cool}, using archival Chandra X-ray data and acquire the SFR and systematic uncertainty in the SFR by combining over 330 estimates from dozens of literature sources. With these data, we estimate the efficiency with which the ICM cools and forms stars, finding {ε }cool}\\equiv {SFR}/{\\dot{M}}cool}=1.4 % +/- 0.4% for systems with {\\dot{M}}cool}> 30 M ⊙ yr‑1. For these systems, we measure a slope in the SFR–{\\dot{M}}cool} relation greater than unity, suggesting that the systems with the strongest cool cores are also cooling more efficiently. We propose that this may be related to, on average, higher black hole accretion rates in the strongest cool cores, which could influence the total amount (saturating near the Eddington rate) and dominant mode (mechanical versus radiative) of feedback. For systems with {\\dot{M}}cool}< 30 M ⊙ yr‑1, we find that the SFR and {\\dot{M}}cool} are uncorrelated and show that this is consistent with star formation being fueled at a low (but dominant) level by recycled ISM gas in these systems. We find an intrinsic log-normal scatter in SFR at a fixed {\\dot{M}}cool} of 0.52 ± 0.06 dex (1σ rms), suggesting that cooling is tightly self-regulated over very long timescales but can vary dramatically on short timescales. There is weak evidence that this scatter may be related to the feedback mechanism, with the scatter being minimized (∼0.4 dex) for systems for which the mechanical feedback power is within a factor of two of the cooling luminosity.

  7. 34 CFR 104.45 - Housing.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false Housing. 104.45 Section 104.45 Education Regulations of... Postsecondary Education § 104.45 Housing. (a) Housing provided by the recipient. A recipient that provides housing to its nonhandicapped students shall provide comparable, convenient, and accessible housing to...

  8. 45 CFR 605.45 - Housing.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 3 2010-10-01 2010-10-01 false Housing. 605.45 Section 605.45 Public Welfare... § 605.45 Housing. (a) Housing provided by the recipient. A recipient that provides housing to its nonhandicapped students shall provide comparable, convenient, and accessible housing to handicapped students at...

  9. Exergoeconomic optimization of coaxial tube evaporators for cooling of high pressure gaseous hydrogen during vehicle fuelling

    International Nuclear Information System (INIS)

    Jensen, Jonas K.; Rothuizen, Erasmus D.; Markussen, Wiebke B.

    2014-01-01

    Highlights: • Three concepts of cooling hydrogen were identified. • A numerical heat transfer model of a coaxial-tube evaporator was built. • The cost of exergy destruction and capital investment cost was evaluated for a range of feasible solution. • The exergoeconomic optimum design for all three concepts was identified. • Cooling with a two-stage evaporator reduces total cost 45% compared to a one-stage evaporator. - Abstract: Gaseous hydrogen as an automotive fuel is reaching the point of commercial introduction. Development of hydrogen fuelling stations considering an acceptable fuelling time by cooling the hydrogen to −40 °C has started. This paper presents a design study of coaxial tube ammonia evaporators for three different concepts of hydrogen cooling, one one-stage and two two-stage processes. An exergoeconomic optimization is imposed to all three concepts to minimize the total cost. A numerical heat transfer model is developed in Engineer Equation Solver, using heat transfer and pressure drop correlations from the open literature. With this model the optimal choice of tube sizes and circuit numbers are found for all three concepts. The results show that cooling with a two-stage evaporator after the pressure reduction valve yields the lowest total cost, 45% lower than the highest, which is with a one-stage evaporator. The main contribution to the total cost was the cost associated with exergy destruction, the capital investment cost contributed with 5–14%. The main contribution to the exergy destruction was found to be thermally driven. The pressure driven exergy destruction accounted for 3–9%

  10. Situation based housing

    DEFF Research Database (Denmark)

    Duelund Mortensen, Peder; Welling, Helen; Wiell Nordberg, Lene

    2007-01-01

    of the average family's lifestyle. These dwellings were ground-breaking when they were built, but today are clearly a product of their time. The reaction to functionalism and the postwar mass production gave rise to flexible dwelling with countless possibilities for room division. The housing of this period has...... characteristics which in the long run have proven to be unfortunate both in terms in terms of durability and architectural quality. Today there is a focus on the development of more open and functionally non-determined housing. A number of new housing schemes in and around Copenhagen reveal a variety...... of approaches to these goals. This working paper reviews not only a selection of new housing types, but also dwellings from the past, which each contain an aspect of changeability. Our study is based on information from users in the selected housing schemes, gathered from questionnaires, information about...

  11. Boosted Fast Flux Loop Alternative Cooling Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Glen R. Longhurst; Donna Post Guillen; James R. Parry; Douglas L. Porter; Bruce W. Wallace

    2007-08-01

    The Gas Test Loop (GTL) Project was instituted to develop the means for conducting fast neutron irradiation tests in a domestic radiation facility. It made use of booster fuel to achieve the high neutron flux, a hafnium thermal neutron absorber to attain the high fast-to-thermal flux ratio, a mixed gas temperature control system for maintaining experiment temperatures, and a compressed gas cooling system to remove heat from the experiment capsules and the hafnium thermal neutron absorber. This GTL system was determined to provide a fast (E > 0.1 MeV) flux greater than 1.0E+15 n/cm2-s with a fast-to-thermal flux ratio in the vicinity of 40. However, the estimated system acquisition cost from earlier studies was deemed to be high. That cost was strongly influenced by the compressed gas cooling system for experiment heat removal. Designers were challenged to find a less expensive way to achieve the required cooling. This report documents the results of the investigation leading to an alternatively cooled configuration, referred to now as the Boosted Fast Flux Loop (BFFL). This configuration relies on a composite material comprised of hafnium aluminide (Al3Hf) in an aluminum matrix to transfer heat from the experiment to pressurized water cooling channels while at the same time providing absorption of thermal neutrons. Investigations into the performance this configuration might achieve showed that it should perform at least as well as its gas-cooled predecessor. Physics calculations indicated that the fast neutron flux averaged over the central 40 cm (16 inches) relative to ATR core mid-plane in irradiation spaces would be about 1.04E+15 n/cm2-s. The fast-to-thermal flux ratio would be in excess of 40. Further, the particular configuration of cooling channels was relatively unimportant compared with the total amount of water in the apparatus in determining performance. Thermal analyses conducted on a candidate configuration showed the design of the water coolant and

  12. How healthy and sustainable is the Dutch housing mix? Measuring and comparing the theoretical housing market balance of Dutch regional housing markets

    Directory of Open Access Journals (Sweden)

    Leonie B. Janssen-Jansen

    2015-01-01

    Full Text Available Housing and its distribution over groups of households dominates debates on urban socio-spatial justice. Amsterdam even received the label ‘Just City’ as the large stock of social housing in the core of the city is said to increase societal equity. Within the Netherlands, however, the Greater Amsterdam housing market is perceived to be the most dysfunctional. As the discussion is fed by highly political and ideological perspectives, it is difficult to assess at face value how balanced the housing mix of a housing market is and to what extent it meets the community’s needs. Consequently, it is difficult to inform politicians about strategies that contribute to a healthy and sustainable housing mix and address the lack of affordable housing which is high on urban policy agendas worldwide. In an attempt to go beyond ideological and political discussions, the aim of this interdisciplinary paper is to develop a metric to measure and compare the theoretical balance of housing markets across regions and across groups of households based on income. The metric will be applied to the case of the Netherlands. The findings of the theoretical model show that large-scale provisions for low-income households may not always result in an improved housing market balance.

  13. Economical Efficiency of Combined Cooling Heating and Power Systems Based on an Enthalpy Method

    Directory of Open Access Journals (Sweden)

    Yan Xu

    2017-11-01

    Full Text Available As the living standards of Chinese people have been improving, the energy demand for cooling and heating, mainly in the form of electricity, has also expanded. Since an integrated cooling, heating and power supply system (CCHP will serve this demand better, the government is now attaching more importance to the application of CCHP energy systems. Based on the characteristics of the combined cooling heating and power supply system, and the method of levelized cost of energy, two calculation methods for the evaluation of the economical efficiency of the system are employed when the energy production in the system is dealt with from the perspective of exergy. According to the first method, fuel costs account for about 75% of the total cost. In the second method, the profits from heating and cooling are converted to fuel costs, resulting in a significant reduction of fuel costs, accounting for 60% of the total cost. Then the heating and cooling parameters of gas turbine exhaust, heat recovery boiler, lithium-bromide heat-cooler and commercial tariff of provincial capitals were set as benchmark based on geographic differences among provinces, and the economical efficiency of combined cooling heating and power systems in each province were evaluated. The results shows that the combined cooling heating and power system is economical in the developed areas of central and eastern China, especially in Hubei and Zhejiang provinces, while in other regions it is not. The sensitivity analysis was also made on related influencing factors of fuel cost, demand intensity in heating and cooling energy, and bank loans ratio. The analysis shows that the levelized cost of energy of combined cooling heating and power systems is very sensitive to exergy consumption and fuel costs. When the consumption of heating and cooling energy increases, the unit cost decreases by 0.1 yuan/kWh, and when the on-grid power ratio decreases by 20%, the cost may increase by 0.1 yuan

  14. Immigrants and the City: The Relevance of Immigration on Housing Price Gradient

    Directory of Open Access Journals (Sweden)

    Valentina Antoniucci

    2017-10-01

    Full Text Available Foreign citizens are a more and more significant part of the population of Italian cities and society (8% of the country’s total population, and they contribute to changes in the cultural, social, and economic structure of the country. Our aim was to assess the incidence of the immigrant population on urban house price polarization, as measured using an original indicator: the center-periphery housing price gradient. While there is ample literature on the relationship between average prices and immigrant populations, less research has been conducted on immigration and the housing price gradient on a national scale. This price gradient may indicate whether immigration contributes to changing the residential market, also possibly revealing segregation phenomena. We ran multivariate regressions in several steps on an original dataset of housing prices and socio-economic factors concerning 112 Italian provincial capitals to elucidate whether immigration is correlated with the housing market divide. Our main findings confirmed that larger immigrant populations coincide with steeper housing price gradients on a national scale. Our tests also demonstrated that the relevance of this phenomenon varies for different urban forms, confirming related to housing price dynamics between the cities of northern and southern Italy the relevance of urban density in elucidating.

  15. 75 FR 5706 - Federal Housing Administration: Insurance for Manufactured Housing: Reopening of Public Comment...

    Science.gov (United States)

    2010-02-04

    ... 2502-AI45 Federal Housing Administration: Insurance for Manufactured Housing: Reopening of Public.... ACTION: Proposed rule; reopening of public comment period. SUMMARY: On September 15, 2008, HUD published a proposed rule entitled ``Federal Housing Administration: Insurance for Manufactured Housing.'' The...

  16. Environmental effects of cooling system alternatives at inland and coastal sites

    International Nuclear Information System (INIS)

    Miner, R.M.; Warrick, J.W.

    1975-01-01

    The environmental effects of alternative cooling systems for power plants in California were analyzed. At inland sites evaporative cooling systems must be used, with fresh water or waste water used as makeup. Because fresh water is scarce, most new plants would need to use agricultural or municipal waste waters. For agricultural waste water systems, disposing of the blowdown and dispersion of drift containing total dissolved solids are two significant problems requiring resolution. At coastal sites, once-through cooling systems or recirculating systems could be used. Once--through cooling causes fewer effects on the marine environment than do recirculating systems on the air and marine environment when oceans water makeup is used. In general, for a recirculating system, dispersing high-salinity blowdown in marine waters and the effects of salt water drift on the terrestrial ecology outweigh the effects of once-through warm water on marine life. (U.S.)

  17. 24 CFR 3.405 - Housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Housing. 3.405 Section 3.405 Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development... Discrimination on the Basis of Sex in Education Programs or Activities Prohibited § 3.405 Housing. (a) Generally...

  18. The architects house

    DEFF Research Database (Denmark)

    Welling, Helen

    2007-01-01

    The architects house is an article on Edward Heiberg's own house built in 1924. Edward Heiberg was a strong advocate of functionalism, and of the notion that hitherto individualistic and emotional architecture should be replaced by an objective function-based architecture with dwellings...... for everyone. In 1924 he designed a house for himself and his family: one of the first examples of functionalism in Denmark....

  19. TARP Monthly Housing Scorecard

    Data.gov (United States)

    Department of the Treasury — Treasury and the U.S. Department of Housing and Urban Development (HUD) jointly produce a Monthly Housing Scorecard on the health of the nation’s housing market. The...

  20. Effects of cooling portions of the head on human thermoregulatory response.

    Science.gov (United States)

    Katsuura, T; Tomioka, K; Harada, H; Iwanaga, K; Kikuchi, Y

    1996-03-01

    Seven healthy young male students participated in this study. Each subject sat on a chair in an anteroom at 25 degrees C for 30 min and then entered a climatic chamber, controlled at 40 degrees C and R.H. 50%, and sat on a chair for 90 min. Cooling of frontal portion including the region around the eyes (FC), occipital portion (OC), and temporal portion (TC) began after 50 min of entering. An experiment without head cooling (NC) was also made for the control measurement. Thermal comfort and thermal sensation were improved by head cooling, but response was the same regardless of portion cooled. Although rectal temperature, mean skin temperature and heart rate showed no significant effect due to head cooling, forearm skin blood flow (FBF), sweat rate (SR), and body weight loss (delta Wt) had a tendency to be depressed. FBF in FC and TC decreased during head cooling, but that in OC and NC did not change significantly, while SR in FC was depressed. delta Wt showed total sweating to decrease by FC and TC, and FC to have greater inhibitory effect on sweating than OC. Thermal strain was evaluated by the modified Craig Index (I(s)). I(s) in FC decreased significantly more than in NC. Cooling of other portions of the head had no significant effect on I(s). Cooling of the frontal portion of the head may thus be concluded to have the most effect on thermoregulatory response in a hot environment.

  1. Assisted Housing - Public Housing Buildings - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The approximate physical location of each individual Public Housing Building. If the building has more than one entrance or street address, the address of the...

  2. Steady state thermal-hydraulic analyses of the MITICA cooling circuits

    Energy Technology Data Exchange (ETDEWEB)

    Zaupa, M., E-mail: matteo.zaupa@igi.cnr.it [Università degli Studi di Padova, Via 8 Febbraio 2, Padova 35122 (Italy); Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy); Sartori, E.; Dalla Palma, M.; Fellin, F.; Marcuzzi, D.; Pavei, M.; Rizzolo, A. [Consorzio RFX, Corso Stati Uniti 4, Padova 35127 (Italy)

    2016-02-15

    Megavolt ITER Injector Concept Advancement is the full scale prototype of the heating and current drive neutral beam injectors for ITER, to be built at Consorzio RFX (Padova). The engineering design of its components is challenging: the total heat loads they will be subjected to (expected between 2 and 19 MW), the high heat fluxes (up to 20 MW/m{sup 2}), and the beam pulse duration up to 1 h, set demanding requirements for reliable active cooling circuits. In support of the design, the thermo-hydraulic behavior of each cooling circuit under steady state condition has been investigated by using one-dimensional models. The final results, obtained considering a number of optimizations for the cooling circuits, show that all the requirements in terms of flow rate, temperature, and pressure drop are properly fulfilled.

  3. Emergency cooling system for a gas-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Cook, R.K.; Burylo, P.S.

    1975-01-01

    The site of the gas-cooled reactor with direct-circuit gas turbine is preferably the sea coast. An emergency cooling system with safety valve and emergency feed-water addition is designed which affects at least a part of the reactor core coolant after leaving the core. The emergency cooling system includes a water emergency cooling circuit with heat exchanger for the core coolant. The safety valve releases water or steam from the emergency coolant circuit when a certain temperature is exceeded; this is, however, replaced by the emergency feed-water. If the gas turbine exhibits a high and low pressure turbine stage, which are flowed through by coolant one behind another, a part of the coolant can be removed in front of each part turbine by two valves and be added to the haet exchanger. (RW/LH) [de

  4. Inadequate housing in Ghana

    Directory of Open Access Journals (Sweden)

    Franklin Obeng-Odoom

    2011-01-01

    Full Text Available Two themes are evident in housing research in Ghana. One involves the study of how to increase the number of dwellings to correct the overall housing deficit, and the other focuses on how to improve housing for slum dwellers. Between these two extremes, there is relatively little research on why the existing buildings are poorly maintained. This paper is based on a review of existing studies on inadequate housing. It synthesises the evidence on the possible reasons for this neglect, makes a case for better maintenance and analyses possible ways of reversing the problem of inadequate housing.

  5. Skin cooling maintains cerebral blood flow velocity and orthostatic tolerance during tilting in heated humans

    Science.gov (United States)

    Wilson, Thad E.; Cui, Jian; Zhang, Rong; Witkowski, Sarah; Crandall, Craig G.

    2002-01-01

    Orthostatic tolerance is reduced in the heat-stressed human. The purpose of this project was to identify whether skin-surface cooling improves orthostatic tolerance. Nine subjects were exposed to 10 min of 60 degrees head-up tilting in each of four conditions: normothermia (NT-tilt), heat stress (HT-tilt), normothermia plus skin-surface cooling 1 min before and throughout tilting (NT-tilt(cool)), and heat stress plus skin-surface cooling 1 min before and throughout tilting (HT-tilt(cool)). Heating and cooling were accomplished by perfusing 46 and 15 degrees C water, respectively, though a tube-lined suit worn by each subject. During HT-tilt, four of nine subjects developed presyncopal symptoms resulting in the termination of the tilt test. In contrast, no subject experienced presyncopal symptoms during NT-tilt, NT-tilt(cool), or HT-tilt(cool). During the HT-tilt procedure, mean arterial blood pressure (MAP) and cerebral blood flow velocity (CBFV) decreased. However, during HT-tilt(cool), MAP, total peripheral resistance, and CBFV were significantly greater relative to HT-tilt (all P heat-stressed humans.

  6. Student Housing a Resilient Housing Rental Market: Case of Federal Polytechnic Neighbourhood Bauchi, Nigeria

    Directory of Open Access Journals (Sweden)

    Zubairu Abubakar Ghani

    2018-03-01

    Full Text Available In the last three decades globally higher institutions (HIs have been experiencing an unprecedented upsurge in student population and student enrolment in His generally outstrip the HIs student housing. In many countries of the world like Nigeria, HIs are obviously incapacitated in accommodating the growing student population which compelled numerous students to overflow into their HIs’ neighbourhood seeking for alternative housing accommodation in the private housing rental market. Indeed the scenario of HIs student's housing shortfalls and increasing students housing demand evolved the interest of many people in a student housing rental market. This is because it has been uncovered that business in student housing rental is lucrative and guaranteeing business that ensured profit for a long term. This paper, therefore, explores the nature and landscape of student housing rental in Nigeria where the business is immature then drawn the conclusion.

  7. The Use of UAV in Housing Renovation Identification: A Case Study at Taman Manis 2

    Science.gov (United States)

    Mustaffa, A. A.; Hasmori, M. F.; Sarif, A. S.; Ahmad, N. F.; Zainun, N. Y.

    2018-04-01

    Housing industry in Malaysia is growing rapidly due to the increase in population and the arising of economic level of Malaysian people. Most residential houses are built according to the standard residential design that may lead to house renovation by the buyers after purchasing the house. A method of using Unmanned Aerial Vehicle (UAV) monitoring was used to obtain information of the renovated houses directly on-site at Taman Manis 2, Parit Raja, Batu Pahat. Through comparison of image captured by the UAV with the original house plans, we found out that a total of 160 units out of 336 units of houses undergo a renovation process. Surprisingly, 41 units have been renovated illegally which has 40% to 96% of renovation rate. The acquired data were analyzed and can be concluded that the method of using UAVs to obtain information is highly recommended. The study is expected to help Municipal Council to detect improper & illegal renovation by the residents in a residential area.

  8. 24 CFR 882.403 - ACC, housing assistance payments contract, and lease.

    Science.gov (United States)

    2010-04-01

    ... DIRECT LOAN PROGRAM, SECTION 202 SUPPORTIVE HOUSING FOR THE ELDERLY PROGRAM AND SECTION 811 SUPPORTIVE... contracted for is the total of the Moderate Rehabilitation Fair Market Rents for all the units. The fee for...

  9. Effect of passive cooling strategies on overheating in low energy residential buildings for Danish climate

    DEFF Research Database (Denmark)

    Simone, Angela; Avantaggiato, Marta; de Carli, Michele

    2014-01-01

    creating not negligible thermal discomfort. In the present work the effect of passive strategies, such as solar shading and natural night-time ventilation, are evaluated through computer simulations. The analyses are performed for 1½-storey single-family house in Copenhagen’s climate. The main result......Climate changes have progressively produced an increase of outdoors temperature resulting in tangible warmer summers even in cold climate regions. An increased interest for passive cooling strategies is rising in order to overcome the newly low energy buildings’ overheating issue. The growing level...

  10. Assisted Housing - Multifamily Properties - Assisted

    Data.gov (United States)

    Department of Housing and Urban Development — HUD's Multifamily Housing property portfolio consist primarily of rental housing properties with five or more dwelling units such as apartments or town houses, but...

  11. Comparison of CO2 Fixation in Wood Used for Residence HOuses in Japan and Korea

    OpenAIRE

    Choi, Soo Im; Sakai, Masahiro; Jeong, In Soo; Oh, Seung Won; Kang, Hag Mo

    2003-01-01

    In this study, we have estimated the amount of carbon (C) fixation in wooden materials used for residence house units in Japan and Korea. This type of C fixation might be helpful to prevent the global warming. In year 2000, the amount of C fixation in the wooden materials was approximately 7.3% (150 million C ton) of total forest C accumulation in Japan, whereas in Korea, it was 2.0% (4.3million C ton) of the total forest C accumulation. The reason is that structural types of the house units ...

  12. Optimal control and performance test of solar-assisted cooling system

    KAUST Repository

    Huang, B.J.

    2010-10-01

    The solar-assisted cooling system (SACH) was developed in the present study. The ejector cooling system (ECS) is driven by solar heat and connected in parallel with an inverter-type air conditioner (A/C). The cooling load can be supplied by the ECS when solar energy is available and the input power of the A/C can be reduced. In variable weather, the ECS will probably operate at off-design condition of ejector and the cooling capability of the ECS can be lost completely. In order to make the ejector operate at critical or non-critical double-choking condition to obtain a better performance, an electronic expansion valve was installed in the suction line of the ejector to regulate the opening of the expansion valve to control the evaporator temperature. This will make the SACH always produce cooling effect even at lower solar radiation periods while the ejector performs at off-design conditions. The energy saving of A/C is experimentally shown 50-70% due to the cooling performance of ECS. The long-term performance test results show that the daily energy saving is around 30-70% as compared to the energy consumption of A/C alone (without solar-driven ECS). The total energy saving of A/C is 52% over the entire test period. © 2010 Elsevier Ltd. All rights reserved.

  13. 24 CFR 1715.27 - Fair housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fair housing. 1715.27 Section 1715.27 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR HOUSING-FEDERAL HOUSING COMMISSIONER, DEPARTMENT OF HOUSING AND URBAN...

  14. Friendly vertical housing: case of walk-up flat housing development in Yogyakarta

    Science.gov (United States)

    Fosterharoldas Swasto, Deva

    2018-03-01

    In Yogyakarta Province, the local government have developed walk-up flats housing for more than ten years since the mid of the 2000s. Yogyakarta City and Sleman Regency was pioneering the construction with some blocks of flats in several locations. However, after this period, there is limited evaluation about the effectiveness of the occupancy. One of the issues is related to the sustainable housing development. Concerning this situation, it is proposed to examine how the development of walk-up flats housing in Yogyakarta City and Sleman Regency can be evaluated based on specific housing indicator, as a part of sustainable housing development concept. This paper would like to explore the phenomenon on how ‘friendly’ the flats is. The researcher will qualitatively asses variables from the walk-up flat cases in Yogyakarta City and Sleman Regency. The results suggested that the physical quality of the vertical housing situation could be enhanced to meet residents’ satisfaction.

  15. Storage of HLW in engineered structures: air-cooled and water-cooled concepts

    International Nuclear Information System (INIS)

    Ahner, S.; Dekais, J.J.; Puttke, B.; Staner, P.

    1981-01-01

    A comparative study on an air-cooled and a water-cooled intermediate storage of vitrified, highly radioactive waste (HLW) in overground installations has been performed by Nukem and Belgonucleaire respectively. In the air-cooled storage concept the decay heat from the storage area will be removed using natural convection. In the water-cooled storage concept the decay heat is carried off by a primary and secondary forced-cooling system with redundant and diverse devices. The safety study carried out by Nukem used a fault tree method. It shows that the reliability of the designed water-cooled system is very high and comparable to the inherent, safe, air-cooled system. The impact for both concepts on the environment is determined by the release route, but even during accident conditions the release is far below permissible limits. The economic analysis carried out by Belgonucleaire shows that the construction costs for both systems do not differ very much, but the operation and maintenance costs for the water-cooled facility are higher than for the air cooled facility. The result of the safety and economic analysis and the discussions with the members of the working group have shown some possible significant modifications for both systems, which are included in this report. The whole study has been carried out using certain national criteria which, in certain Member States at least, would lead to a higher standard of safety than can be justified on any social, political or economic grounds

  16. Housing and Social Environments of African (Loxodonta africana and Asian (Elephas maximus Elephants in North American Zoos.

    Directory of Open Access Journals (Sweden)

    Cheryl L Meehan

    Full Text Available We evaluated 255 African (Loxodonta africana and Asian (Elephas maximus elephants living in 68 North American zoos over one year to quantify housing and social variables. All parameters were quantified for the both the day and the night and comparisons were made across these time periods as well as by species and sex. To assess housing, we evaluated not only total exhibit size, but also individual animals' experiences based on the time they spent in the unique environments into which the exhibits were subdivided. Variables developed to assess housing included measurements of area as a function of time (Total Space Experience, environment type (Indoor, Outdoor, In/Out Choice and time spent on hard and soft flooring. Over the year, Total Space Experience values ranged from 1,273 square feet to 169,692 square feet, with Day values significantly greater than Night values (p<0.001. Elephants spent an average of 55.1% of their time outdoors, 28.9% indoors, and 16% in areas with a choice between being in or out. Time spent on hard flooring substrate ranged from 0% to 66.7%, with Night values significantly greater than Day (p<0.001. Social factors included number of animals functionally housed together (Social Experience and social group characteristics such as time spent with juveniles and in mixed-sex groups. Overall Social Experience scores ranged from 1 to 11.2 and were significantly greater during the Day than at Night (p<0.001. There were few significant social or housing differences between African (N = 138 and Asian (N = 117 species or between males (N = 54 and females (N = 201. The most notable exception was Total Space Experience, with African and male elephants having larger Total Space Experience than Asian and female elephants, respectively (P-value<0.05. The housing and social variables evaluated herein have been used in a series of subsequent epidemiological analyses relating to various elephant welfare outcomes.

  17. Electrically-cooled HPGe detector for advanced x-ray spectroscopy and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marian, V.; Clauss, J.; Pirard, B.; Quirin, P.; Flamanc, J.; Lampert, M.O. [CANBERRA France, Parc des Tanneries, 1, chemin de la roseraie, 67380 Lingolsheim (France)

    2015-07-01

    High Purity Germanium (HPGe) detectors are used for high-resolution x- and gamma-ray spectroscopy. For their operation, the necessary cryogenic cooling is performed with liquid nitrogen or with electromechanical coolers. Although mature and industrialized solutions, most of HPGe detectors integrating electrical coolers present a limited spectroscopic performance due to the generated mechanical vibration and electromagnetic interference. This paper describes a novel HPGe detector, specifically designed to address the challenges of ultimate x-ray spectroscopy and imaging applications. Due to the stringent demands associated with nano-scale imaging in synchrotron applications, a custom-designed cryostat was built around a Canberra CP5-Plus electrical cooler featuring extremely low vibration levels and high cooling power. The heat generated by the cryo-cooler itself, as well as the electronics, is evacuated via an original liquid cooling circuit. This architecture can also be used to address high ambient temperature, which does not allow conventional cryo-coolers to work properly. The multichannel detector head can consist of a segmented monolithic HPGe sensor, or several closely packed sensors. Each sensor channel is read out by state-of-the-art pulse-reset preamplifiers in order to achieve excellent energy resolution for count rates in excess of 1 Mcps. The sensitive electronics are located in EMI-proof housings to avoid any interference from other devices on a beam-line. The front-end of the detector is built using selected high-purity materials and alloys to avoid any fluorescence effects. We present a detailed description of the detector design and we report on its performance. A discussion is also given on the use of electrically cooled HPGe detectors for applications requiring ultimate energy resolution, such as synchrotron, medicine or nuclear industry. (authors)

  18. American Housing Survey (AHS)

    Data.gov (United States)

    Department of Housing and Urban Development — The AHS is the largest, regular national housing sample survey in the United States. The U.S. Census Bureau conducts the AHS to obtain up-to-date housing statistics...

  19. Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2011-10-01

    This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVAC companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational

  20. Social factors affect motor and anxiety behaviors in the animal model of attention-deficit hyperactivity disorders: A housing-style factor.

    Science.gov (United States)

    Tsai, Meng-Li; Kozłowska, Anna; Li, Yu-Sheng; Shen, Wen-Ling; Huang, Andrew Chih Wei

    2017-08-01

    The present study examines whether housing style (e.g., single housing, same-strain-grouped housing, and different-strain-grouped housing) and rat strain (e.g., spontaneous hypertension rats [SHR] and Wistar-Kyoto rats [WKY]) mediate motor function and anxiety behavior in the open field task. From week 4 through week 10 following birth, the rats were measured 30min for locomotor activity and anxiety once per week in the open field task. The SHR rats exhibited hyperactivity in total distance traveled and movement time to form the animal model of ADHD. The SHR rats spent more time inside the square and crossed the inside-outside line more often than the WKY rats, indicating the SHR rats exhibited less anxiety behavior. The different-strain-grouped housing style (but neither the same-strain-grouped housing style nor the single housing style) decreased total distance traveled and facilitated anxiety behavior. The motor function was negatively correlated with anxiety behavior for SHR rats but not for WKY rats. Housing styles had a negative correlation between motor function and anxiety behavior. The present findings provide some insights regarding how social factors (such as housing style) affect motor function and anxiety behavior related to ADHD in a clinical setting. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  1. United States housing, 2012

    Science.gov (United States)

    Delton Alderman

    2013-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.

  2. "House Arrest" or "Developmental Arrest"? A Study of Youth Under House Arrest.

    Science.gov (United States)

    Chamiel, Elad; Walsh, Sophie D

    2018-06-01

    Studies have examined the potential benefits and risks of alternative forms of detention, such as house arrest, for adults but, despite its growing use, little research has examined the implications of house arrest for juveniles. The current research examined the experience of 14 adolescents under house arrest. Six main themes were identified in the narratives of the participants: the experience of detention, daily schedule and utilization of time, emotions and self-reflection, relationships with peers, relation to parents and supervisor(s), and contact with professionals. Findings emphasized the potential developmental dangers of house arrest at the critical stage of adolescence. Yet, analysis also showed that the period of house arrest has the potential to be a period of positive changes, and can be used for successful rehabilitation.

  3. Immigrants and the City: The Relevance of Immigration on Housing Price Gradient

    OpenAIRE

    Valentina Antoniucci; Giuliano Marella

    2017-01-01

    Foreign citizens are a more and more significant part of the population of Italian cities and society (8% of the country’s total population), and they contribute to changes in the cultural, social, and economic structure of the country. Our aim was to assess the incidence of the immigrant population on urban house price polarization, as measured using an original indicator: the center-periphery housing price gradient. While there is ample literature on the relationship between average prices ...

  4. Cooling water distribution system

    Science.gov (United States)

    Orr, Richard

    1994-01-01

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  5. Preliminary study of the relationship between surface and bulk water temperatures at the Dresden cooling pond

    International Nuclear Information System (INIS)

    Wesely, M.L.; Hicks, B.B.; Hess, G.D.

    1975-01-01

    Successful application of bulk aerodynamic formulae to determine the vertical sensible and latent heat fluxes above a cooling lake requires accurate estimates of water surface temperature. Because of the heat loss at the surface and partial insulation by the poorly-mixed outer skin of water in contact with the air-water interface, the surface temperature is usually 0.1 to 2.0 C less than the temperature at a depth greater than 1 cm. For engineering applications requiring estimates of the total heat dissipation capacity of a particular cooling lake, the bulk temperature of the entire mixed layer of subsurface water is more important than the surface temperature. Therefore, in order to simulate the thermal performance of a cooling pond, both the surface temperature and the bulk temperature should be estimated. In the case of cooling ponds, the total heat transfer through the uppermost layer is extremely large and the water beneath the surface is strongly mixed by circulation currents within the pond. The purpose of this report is to describe the magnitude of the temperature difference across the surface skin at the Dresden nuclear power plant cooling pond and to relate this difference to variables used in modeling the thermal performance of cooling ponds

  6. Assisted Housing - Low Income Housing Tax Credit Properties - National Geospatial Data Asset (NGDA)

    Data.gov (United States)

    Department of Housing and Urban Development — The Low-Income Housing Tax Credit (LIHTC) is the primary Federal program for creating affordable housing in the United States. The LIHTC database, created by HUD and...

  7. A Painted House In Ankara: Dedebayrak House

    Directory of Open Access Journals (Sweden)

    Muzaffer Karaaslan

    2016-06-01

    Full Text Available The conservative family lifestyle in the Ottoman State affected the ways that houses were planned and decorated. Different decorative programs emerged with major differences in each period. New techniques and styles began to be seen in the 18th century thanks to the influence of the West. This article will focus on the decoration of Dedebayrak House in Ankara. Decoration in the architecture found within the boundaries of Ankara consist mostly of geometrical or floral decorations and various inscriptions. The Dedebayrak House not only has these kind of decorations, but also it has these decorations in its architectural descriptions, so it makes this house the only one to have survived in Ankara. Moreover, this building is especially important as the décor included work belonging to Nakkaş Mustafa. However, these decorative features do not remain today. The situation in Turkey is such that architecture is not conserved, which leads to many historically important buildings vanishing. Neither local authorities, nor the owner of these buildings look after these buildings properly, leading their specific historical features to be lost. This situation both damages the urban fabric and harms the historical heritage of the city. Therefore, decorative features in the building will be analysed both on their own and compared to other buildings in Ankara in order to create an overall picture.

  8. Reducing water consumption of an industrial plant cooling unit using hybrid cooling tower

    International Nuclear Information System (INIS)

    Rezaei, Ebrahim; Shafiei, Sirous; Abdollahnezhad, Aydin

    2010-01-01

    Water consumption is an important problem in dry zones and poor water supply areas. For these areas use of a combination of wet and dry cooling towers (hybrid cooling) has been suggested in order to reduce water consumption. In this work, wet and dry sections of a hybrid cooling tower for the estimation of water loss was modeled. A computer code was also written to simulate such hybrid cooling tower. To test the result of this simulation, a pilot hybrid tower containing a wet tower and 12 compact air cooled heat exchangers was designed and constructed. Pilot data were compared with simulation data and a correction factor was added to the simulation. Ensuring that the simulation represents the actual data, it was applied to a real industrial case and the effect of using a dry tower on water loss reduction of this plant cooling unit was investigated. Finally feasibility study was carried out to choose the best operating conditions for the hybrid cooling tower configuration proposed for this cooling unit.

  9. Is Housing a Health Insult?

    Science.gov (United States)

    Baker, Emma; Beer, Andrew; Lester, Laurence; Pevalin, David; Whitehead, Christine; Bentley, Rebecca

    2017-05-26

    In seeking to understand the relationship between housing and health, research attention is often focussed on separate components of people's whole housing 'bundles'. We propose in this paper that such conceptual and methodological abstraction of elements of the housing and health relationship limits our ability to understand the scale of the accumulated effect of housing on health and thereby contributes to the under-recognition of adequate housing as a social policy tool and powerful health intervention. In this paper, we propose and describe an index to capture the means by which housing bundles influence health. We conceptualise the index as reflecting accumulated housing 'insults to health'-an Index of Housing Insults (IHI). We apply the index to a sample of 1000 low-income households in Australia. The analysis shows a graded association between housing insults and health on all outcome measures. Further, after controlling for possible confounders, the IHI is shown to provide additional predictive power to the explanation of levels of mental health, general health and clinical depression beyond more traditional proxy measures. Overall, this paper reinforces the need to look not just at separate housing components but to embrace a broader understanding of the relationship between housing and health.

  10. Adventure of Architecture Example of Housing and Housing Areas

    Directory of Open Access Journals (Sweden)

    Ali Asasoğlu

    2013-08-01

    Full Text Available Housing and the concept of space associated with this requirement are among the initial attitudes towards the human reign over the nature. The dawn of the structured environment found life with this approach within the nature. Both, housing and the housing design process overlap with the historical development of modern man, and is covered within the concept of architecture today. The contribution made by culture within this period is yet another undeniable fact. While the interaction between architecture and culture are moving forward thereby leaving traces in every era throughout the history, the culture of housing and housing design exhibits a parallel attitude which is a subsidiary, yet a highly title with a close human relationship. Culture and architecture are two closely interacting aspects which are drawing the borders of each other from time to time, hinting at quality and quantity, and evaluating such. Quite naturally, the structure which is in a deep relationship with mankind is in an exchange with all physical, social and economic qualities of the human. These qualities are fundamental determinants of the concept of culture as a human trait. The process of architecture which is usually defined as a sequence of eras that involve social movements, impulses and trends, sometimes kept moving ahead in the pursuit of individual leadership and styles. The concerns regarding the solution of space problems, setting up /designing venues and arranging the environment in line with the requirements brought up increasingly complex issues and stacks of solutions which follow such problems. It is this dynamic structure which forms the basis of the architectural problem to date. Starting with the housing and residential concepts, this study brings a critical view on the application samples and methods of the relationship between architecture and culture in terms of our country in particular while putting emphasis on the architectural venture of the

  11. Possibilities of free cooling in prefabricated residential buildings; Moeglichkeiten der freien Kuehlung fuer Wohngebaeude in Fertigbauweise

    Energy Technology Data Exchange (ETDEWEB)

    Truemper, H.; Hain, K.; Wirth, S. [Dortmund Univ. (Germany). Lehrstuhl Technische Gebaeudeausruestung

    1999-07-01

    Due to their efficient heat insulation, modern low-energy houses can develop disagreeably high room temperatures in the summer. Use of room cooling devices for cooling residential buildings in central Europe is not feasible for ecological as well as economic reasons. This paper presents the buried heat exchanger and the cellar wall exchanger as alternatives to the cooling of incoming air in ventilated low-energy residential buildings. Both are in principle cold storages with coiled pipes taking in air from outside. The buried heat exchanger is charged with cold during the heating period (seasonal storage), whereas the cellar wall exchanger accumulates and gives off cold daily. (orig.) [German] In modernen Niedrigenergiehaeusern koennen sich aufgrund einer verbesserten Waermedaemmung waehrend des Sommers Raumtemperaturen einstellen, die nicht als behaglich empfunden werden. Raumkuehlgeraete scheiden aus oekologischen und oekonomischen Gruenden fuer eine Kuehlung von Wohngebaeuden in Mitteleuropa aus. Als Alternativen zur Kuehlung der Zuluft bei Niedrigenergiehaeusern mit Wohnungslueftung werden der Erdwaermeaustauscher und der Kellerwandaustauscher vorgestellt. Hierbei handelt es sich um Kaeltespeicher, in welchen Rohrschlangen verlegt sind, ueber welche die Aussenluft angesaugt wird. Der Erdwaermeaustauscher wird als Kaeltespeicher waehrend der Heizperiode aufgeladen (saisonaler Speicher), wohingegen der Kellerwandaustauscher taeglich be- und entladen wird. (orig.)

  12. Occurrence of Infected Free-Living Amoebae in Cooling Towers of Southern Brazil.

    Science.gov (United States)

    Soares, Scheila S; Souza, Thamires K; Berté, Francisco K; Cantarelli, Vlademir V; Rott, Marilise B

    2017-12-01

    This study determined the occurrence of potentially pathogenic free-living amoebae (FLA) and bacteria associated with amoebae in air-conditioning cooling towers in southern Brazil. Water samples were collected from 36 cooling systems from air-conditioning in the state of Rio Grande do Sul, Brazil. The organisms were identified using polymerase chain reaction (PCR) and sequencing automated. The results showed that these aquatic environments, with variable temperature, are potential "hot spots" for emerging human pathogens like free-living amoebae and bacteria associated. In total, 92% of the cooling-tower samples analyzed were positive for FLA, and Acanthamoeba was the dominant genus by culture and PCR. Amoebal isolates revealed intracellular bacteria in 39.3% of them and all were confirmed as members of the genus Pseudomonas. The results obtained show the important role of cooling towers as a source of amoebae-associated pathogens.

  13. Developmental adjustments of house sparrow (Passer domesticus) nestlings to diet composition.

    Science.gov (United States)

    Brzek, Paweł; Kohl, Kevin; Caviedes-Vidal, Enrique; Karasov, William H

    2009-05-01

    House sparrow nestlings are fed primarily on insects during the first 3 days of their life, and seeds become gradually more important afterwards. We tested whether developmental changes in size and functional capacity of the digestive tract in young house sparrows are genetically hard-wired and independent of diet, or can be modified by food type. Under laboratory conditions, we hand-fed young house sparrows with either a starch-free insect-like diet, based mainly on protein and fat, or a starch-containing diet with a mix of substrates similar to that offered to older nestlings in natural nests when they are gradually weaned from an insect to a seed diet. Patterns of overall development in body size and thermoregulatory ability, and in alimentary organ size increase, were relatively similar in house sparrow nestlings developing on both diets. However, total intestinal maltase activity, important in carbohydrate breakdown, was at least twice as high in house sparrow nestlings fed the starch-containing diet (PFuture studies must test whether the diet-dependent increase in maltase activity during development is irreversible or reversible, reflecting, respectively, a developmental plasticity or a phenotypic flexibility.

  14. Cooling device for reactor container

    International Nuclear Information System (INIS)

    Arai, Kenji.

    1996-01-01

    Upon assembling a static container cooling system to an emergency reactor core cooling system using dynamic pumps in a power plant, the present invention provides a cooling device of lowered center of gravity and having a good cooling effect by lowering the position of a cooling water pool of the static container cooling system. Namely, the emergency reactor core cooling system injects water to the inside of a pressure vessel using emergency cooling water stored in a suppression pool as at least one water source upon loss of reactor coolant accident. In addition, a cooling water pool incorporating a heat exchanger is disposed at the circumference of the suppression pool at the outside of the container. A dry well and the heat exchanger are connected by way of steam supply pipes, and the heat exchanger is connected with the suppression pool by way of a gas exhaustion pipe and a condensate returning pipeline. With such a constitution, the position of the heat exchanger is made higher than an ordinary water level of the suppression pool. As a result, the emergency cooling water of the suppression pool water is injected to the pressure vessel by the operation of the reactor cooling pumps upon loss of coolant accident to cool the reactor core. (I.S.)

  15. The final cool down

    CERN Multimedia

    Thursday 29th May, the cool-down of the final sector (sector 4-5) of LHC has begun, one week after the start of the cool-down of sector 1-2. It will take five weeks for the sectors to be cooled from room temperature to 5 K and a further two weeks to complete the cool down to 1.9 K and the commissioning of cryogenic instrumentation, as well as to fine tune the cryogenic plants and the cooling loops of cryostats.Nearly a year and half has passed since sector 7-8 was cooled for the first time in January 2007. For Laurent Tavian, AT/CRG Group Leader, reaching the final phase of the cool down is an important milestone, confirming the basic design of the cryogenic system and the ability to operate complete sectors. “All the sectors have to operate at the same time otherwise we cannot inject the beam into the machine. The stability and reliability of the cryogenic system and its utilities are now very important. That will be the new challenge for the coming months,” he explains. The status of the cool down of ...

  16. Thermal Predictions of the Cooling of Waste Glass Canisters

    Energy Technology Data Exchange (ETDEWEB)

    Donna Post Guillen

    2014-11-01

    Radioactive liquid waste from five decades of weapons production is slated for vitrification at the Hanford site. The waste will be mixed with glass forming additives and heated to a high temperature, then poured into canisters within a pour cave where the glass will cool and solidify into a stable waste form for disposal. Computer simulations were performed to predict the heat rejected from the canisters and the temperatures within the glass during cooling. Four different waste glass compositions with different thermophysical properties were evaluated. Canister centerline temperatures and the total amount of heat transfer from the canisters to the surrounding air are reported.

  17. Alternative geometry for cylindrical natural draft cooling tower with higher cooling efficiency under crosswind condition

    International Nuclear Information System (INIS)

    Goodarzi, M.; Ramezanpour, R.

    2014-01-01

    Highlights: • Alternative cross sections for natural draft cooling tower were proposed. • Numerical solution was applied to study thermal and hydraulic performances. • Thermal and hydraulic performances were assessed by comparative parameters. • Cooling tower with elliptical cross section had better thermal performance under crosswind. • It could successfully used at the regions with invariant wind direction. - Abstract: Cooling efficiency of a natural draft dry cooling tower may significantly decrease under crosswind condition. Therefore, many researchers attempted to improve the cooling efficiency under this condition by using structural or mechanical facilities. In this article, alternative shell geometry with elliptical cross section is proposed for this type of cooling tower instead of usual shell geometry with circular cross section. Thermal performance and cooling efficiency of the two types of cooling towers are numerically investigated. Numerical simulations show that cooling tower with elliptical cross section improves the cooling efficiency compared to the usual type with circular cross section under high-speed wind moving normal to the longitudinal diameter of the elliptical cooling tower

  18. Semioptimal practicable algorithmic cooling

    International Nuclear Information System (INIS)

    Elias, Yuval; Mor, Tal; Weinstein, Yossi

    2011-01-01

    Algorithmic cooling (AC) of spins applies entropy manipulation algorithms in open spin systems in order to cool spins far beyond Shannon's entropy bound. Algorithmic cooling of nuclear spins was demonstrated experimentally and may contribute to nuclear magnetic resonance spectroscopy. Several cooling algorithms were suggested in recent years, including practicable algorithmic cooling (PAC) and exhaustive AC. Practicable algorithms have simple implementations, yet their level of cooling is far from optimal; exhaustive algorithms, on the other hand, cool much better, and some even reach (asymptotically) an optimal level of cooling, but they are not practicable. We introduce here semioptimal practicable AC (SOPAC), wherein a few cycles (typically two to six) are performed at each recursive level. Two classes of SOPAC algorithms are proposed and analyzed. Both attain cooling levels significantly better than PAC and are much more efficient than the exhaustive algorithms. These algorithms are shown to bridge the gap between PAC and exhaustive AC. In addition, we calculated the number of spins required by SOPAC in order to purify qubits for quantum computation. As few as 12 and 7 spins are required (in an ideal scenario) to yield a mildly pure spin (60% polarized) from initial polarizations of 1% and 10%, respectively. In the latter case, about five more spins are sufficient to produce a highly pure spin (99.99% polarized), which could be relevant for fault-tolerant quantum computing.

  19. Life cycle assessment of energy and CO2 emissions for residential buildings in Jakarta, Indonesia

    Science.gov (United States)

    Surahman, U.; Kubota, T.; Wijaya, A.

    2016-04-01

    In order to develop low energy and low carbon residential buildings, it is important to understand their detailed energy profiles. This study provides the results of life cycle assessment of energy and CO2 emissions for residential buildings in Jakarta, Indonesia. A survey was conducted in the city in 2012 to obtain both material inventory and household energy consumption data within the selected residential buildings (n=300), which are classified into three categories, namely simple, medium and luxurious houses. The results showed that the average embodied energy of simple, medium and luxurious houses was 58.5, 201.0, and 559.5 GJ, respectively. It was found that total embodied energy of each house can be explained by its total floor area alone with high accuracy in respective house categories. Meanwhile, it was seen that operational energy usage patterns varied largely among house categories as well as households especially in the simple and medium houses. The energy consumption for cooling was found to be the most significant factor of the increase in operational energy from simple to luxurious houses. Further, in the life cycle energy, the operational energy accounted for much larger proportions of about 86-92% than embodied energy regardless of the house categories. The life cycle CO2 emissions for medium and luxurious houses were larger than that of simple houses by 2 and 6 times on average. In the simple houses, cooking was the largest contributor to the CO2 emissions (25%), while the emissions caused by cooling increased largely with the house category and became the largest contributors in the medium (26%) and luxurious houses (41%).

  20. In-Migration and Housing Choice in Ho Chi Minh City: Toward Sustainable Housing Development in Vietnam

    Directory of Open Access Journals (Sweden)

    Ducksu Seo

    2017-09-01

    Full Text Available Since the initiation of Vietnam’s Doi Moi policy in 1986, the rate of urbanization has rapidly increased with a great influx of immigrants from rural areas. With such migration becoming a large acceleration factor for urban growth, the shortage of housing has become a critical problem in the cities. The Vietnamese government encouraged self-built housing and public–private partnerships to produce different types of housing stock. There are few available academic studies about housing choice in Vietnam to help understand movement dynamics and to foster sustainable housing development. The purpose of this study is to analyze housing choice and moving determinants in Ho Chi Minh City, and thereby establish recommendations for sustainable housing development in Vietnam. For an empirical study, a citizen questionnaire survey was conducted in HCMC and an in-depth analysis was carried out. The results indicate that the row house type for single-family housing is strongly preferred, but a preference for apartments is also observed for future planning. The factors influencing housing choice and movement are family income, housing ownership, housing typology, and commuting environment. These phenomena suggest that the government should prudently consider affordable housing development in many districts. The results of this study will help to establish policies for sustainable housing development in Ho Chi Minh City, Vietnam.

  1. Housing Programs for Homeless Individuals With Mental Illness: Effects on Housing and Mental Health Outcomes.

    Science.gov (United States)

    Benston, Elizabeth A

    2015-08-01

    This systematic review analyzed the best available research in the United States on permanent supportive housing programs for homeless individuals with mental illness and the effect of these programs on housing status and mental health. It updates older and broader reviews that included weaker studies or those that did not analyze permanent housing as an input and housing and mental health as primary outcomes. The literature search (1980-2013) yielded 14 studies (randomized controlled trials and quasi-experimental studies). The studies found that a majority of participants placed in experimental housing programs with case management support remained in housing for at least one year or experienced more days housed than homeless relative to a comparison group. Although this finding is in line with previous literature reviews on permanent supportive housing, this analysis found limitations in each of the 14 reviewed studies, such as attrition, selection and response bias, imprecise definitions and implementation of housing programs, and a lack of appropriate controls. Only three of the reviewed studies reported using a housing fidelity assessment tool to test whether the housing intervention was faithful to theoretical standards, and conceptions and implementation of housing varied widely across studies, threatening internal and external validity. Pitfalls in the best available studies on permanent supportive housing programs in the United States limit the ability of research to inform the policy goal of ending chronic homelessness and demonstrate a need for further experimental research upon which to make funding and policy decisions, especially in light of prioritized federal funds.

  2. Scottish Passive House: Insights into Environmental Conditions in Monitored Passive Houses

    Directory of Open Access Journals (Sweden)

    Janice Foster

    2016-04-01

    Full Text Available Climate change and sustainability legislation in recent years has led to significant changes in construction approaches in the UK housing sector. This has resulted in the adoption of new building typologies, including the German Passivhaus (Passive House standard. This standard aims to improve occupant comfort and energy efficiency, potentially changing the ways in which homes operate and how occupants interact with them. With increasing construction of low energy dwellings, there is an emerging gap in knowledge in relation to occupant health and wellbeing, thermal comfort, and indoor air quality (IAQ. Using data collected from a two year Building Performance Evaluation (BPE study funded by Innovate UK, the environmental data (temperature, relative humidity and carbon dioxide concentrations from five Certified Passive House homes in Scotland was compared. The results demonstrate problems with overheating with peak temperatures exceeding 30 °C. Imbalanced mechanical ventilation with heat recovery (MVHR systems were identified in 80% of the dwellings and inadequate IAQ was found due to poor ventilation. Only one of the Passive Houses studied exhibited thermal conditions and IAQ which were, on the whole within Passive House parameters. This paper outlines the insights and the main issues of Scottish Passive House in the broader context of sustainability.

  3. Clay Houses

    Science.gov (United States)

    Pedro, Cathy

    2011-01-01

    In this article, the author describes a project designed for fourth-graders that involves making clay relief sculptures of houses. Knowing the clay houses will become a family heirloom makes this lesson even more worth the time. It takes three classes to plan and form the clay, and another two to underglaze and glaze the final products.

  4. Sustainable Housing Design

    DEFF Research Database (Denmark)

    Lauring, Gert Michael

    2016-01-01

    Sustainable Housing Design. Integrating technical and housing quality aspects of sustainable architecture in civil engineering education. Summary An integrated design approach to sustainable architecture is outlined that combines concerns for zero energy building, good indoor climate and adequate...... phases. The outcome shows that integrated design further solutions where sustainable urban forms of settlement can be highly energy efficient while also attractive from a user perspective. Key words: Sustainable architecture, integrated design, zero-energy-housing, dense urban living. 1. Introduction...... When designing sustainable housing, energy optimization and satisfactory indoor climates are central issues that need to be incorporated from early design phases if to reach a coherent design. It might also be argued that the energy consumption of contemporary buildings only plays a rela-tively minor...

  5. Analysis of the Air Cooling for 350 keV/20 mA Electron Beam Machine Rooms

    International Nuclear Information System (INIS)

    Sutadi; Suprapto; Suyamto; Sukaryono

    2003-01-01

    It has been analyzed the cooling capacity for 350 keV/20 mA electron beam machine rooms at P3TM. The analysis of cooling load based on the building construction and the device for supported the electron beam machines operation, were obtained head dissipation and provided the cooling load. From the result it can be determined that for cooling the electron beam machine rooms with 945 m cubic of volume and supporter device in the room, in order to reach the air condition about 20 o C of temperatures and 50 % of relative humidity for the electron beam machine rooms, it was needed the air conditioning system with total cooling capacity about 213.000 BTU/Hours. (author)

  6. Energy and Exergy Analysis for Improving the Energy Performance of Air-Cooled Liquid Chillers by Different Condensing-Coil Configurations

    Directory of Open Access Journals (Sweden)

    Tzong-Shing Lee

    2012-03-01

    Full Text Available This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in air-cooled chillers and the energy conversion efficiency of each component, in order to determine how the angle configuration of condenser coils influences chiller performance. This study found that the overall performance of an air-cooled chiller could be improved by approximately 3.4%, and the total irreversibility could be reduced by approximately 2.7%. With each 1% increase in average wind speed over the condenser coils, the overall performance of an air‑cooled chiller was found to be enhanced by approximately 0.43%, and its total irreversibility was reduced by approximately 0.35%. The results of this study can be effectively applied to air-cooled condenser units, and can provide an important basis of reference for developing and enhancing the energy efficiency of air-cooled chillers.

  7. Design for micro-combined cooling, heating and power systems stirling engines and renewable power systems

    CERN Document Server

    2015-01-01

    ‘Design for Micro-Combined Cooling, Heating & Power Systems’ provides a manual for the technical and structural design of systems for supplying decentralised energy in residential buildings. It presents the micro-combined cooling, heating & power systems Stirling engines & renewable energy sources (mCCHP-SE-RES) systems in an accessible manner both for the public at large, and for professionals who conceive, design or commercialise such systems or their components.  The high performance levels of these systems are demonstrated within the final chapter by the results of an experiment in which a house is equipped with a mCCHP-SE-RES system. The reader is also familiarized with the conceptual, technical and legal aspects of modern domestic energy systems; the components that constitute these systems; and advanced algorithms for achieving the structural and technical design of such systems. In residential buildings, satisfying demands of durable development has gradually evolved from necessity to...

  8. Implementation of gas district cooling and cogeneration systems in Malaysia; Mise en oeuvre de systemes de gas district cooling et de cogeneration en Malaisie

    Energy Technology Data Exchange (ETDEWEB)

    Haron, S. [Gas District Cooling, M, Sdn Bhd (Malaysia)

    2000-07-01

    With its energy demand in the early 1990's growing at a high rate due to the country's strong economic growth, Malaysia studied various options to improve the efficiency of its energy use. Since its natural gas reserves are almost four times that of its crude oil reserves, efforts were therefore centered on seeking ways to boost the use of natural gas to mitigate the growing domestic energy need. PETRONAS, the national oil company, subsequently studied and chose the District Cooling System using natural gas as the primary source of fuel. The Kuala Lumpur City Center development, which houses the PETRONAS Twin Towers, was subsequently chosen as the first project to use the Gas District Cooling (GDC) System. To acquire the technology and implement this project, PETRONAS created a new subsidiary, Gas District Cooling (Malaysia) Sendirian Berhad (GDC(M)). In the process of improving the plant's efficiency, GDC(M) discovered that the GDC system's efficiency and project economics would be significantly enhanced if its is coupled to a Cogeneration system. Having proven the success of the GDC/Cogeneration system, GDC(M) embarked on a campaign to aggressively promote and seek new opportunities to implement the system, both in Malaysia-and abroad. Apart from enhancing efficiency of energy use, and providing better project economics, the GDC/Cogeneration system also is environment friendly. Today, the GDC/Cogeneration systems is the system of choice for several important developments in Malaysia, which also includes the country's prestigious projects such as the Kuala Lumpur International Airport and the New Federal Government Administrative Center in Putrajaya. (author)

  9. Smart Solar Housing Renovation

    NARCIS (Netherlands)

    Ham, M.; Bruijn, de D.M.P.; Vos, S.J.H.; Weijers, K.A.M.; Straver, M.C.W.; Scartezzini, J.L.

    2009-01-01

    After World War II, the demand for houses in the Netherlands was enormous. Large housing construction programs were established in the fifties, sixties and seventies. Nowadays, these houses are facing some societal, economic and technological problems. On the other hand, many of the occupants are

  10. 24 CFR 982.352 - Eligible housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Eligible housing. 982.352 Section 982.352 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR PUBLIC AND INDIAN HOUSING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT...

  11. 24 CFR 1007.20 - Eligible housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Eligible housing. 1007.20 Section 1007.20 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR PUBLIC AND INDIAN HOUSING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT...

  12. 24 CFR 982.619 - Cooperative housing.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Cooperative housing. 982.619 Section 982.619 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR PUBLIC AND INDIAN HOUSING, DEPARTMENT OF HOUSING AND URBAN...

  13. Aero-Thermo-Structural Design Optimization of Internally Cooled Turbine Blades

    Science.gov (United States)

    Dulikravich, G. S.; Martin, T. J.; Dennis, B. H.; Lee, E.; Han, Z.-X.

    1999-01-01

    A set of robust and computationally affordable inverse shape design and automatic constrained optimization tools have been developed for the improved performance of internally cooled gas turbine blades. The design methods are applicable to the aerodynamics, heat transfer, and thermoelasticity aspects of the turbine blade. Maximum use of the existing proven disciplinary analysis codes is possible with this design approach. Preliminary computational results demonstrate possibilities to design blades with minimized total pressure loss and maximized aerodynamic loading. At the same time, these blades are capable of sustaining significantly higher inlet hot gas temperatures while requiring remarkably lower coolant mass flow rates. These results suggest that it is possible to design internally cooled turbine blades that will cost less to manufacture, will have longer life span, and will perform as good, if not better than, film cooled turbine blades.

  14. Computer optimization of dry and wet/dry cooling tower systems for large fossil and nuclear power plants

    International Nuclear Information System (INIS)

    Choi, M.; Glicksman, L.R.

    1979-02-01

    This study determined the cost of dry cooling compared to the conventional cooling methods. Also, the savings by using wet/dry instead of all-dry cooling were determined. A total optimization was performed for power plants with dry cooling tower systems using metal-finned-tube heat exchangers and surface condensers. The optimization minimizes the power production cost. The program optimizes the design of the heat exchanger and its air and water flow rates. In the base case study, the method of replacing lost capacity assumes the use of gas turbines. As a result of using dry cooling towers in an 800 MWe fossil plant, the incremental costs with the use of high back pressure turbine and conventional turbine over all-wet cooling are 11 and 15%, respectively. For a 1200 MWe nuclear plant, these are 22 and 25%, respectively. Since the method of making up lost capacity depends on the situation of a utility, considerable effort has been placed on testing the effects of using different methods of replacing lost capacity at high ambient temperatures by purchased energy. The results indicate that the optimization is very sensitive to the method of making up lost capacity. It is, therefore, important to do an accurate representation of all possible methods of making up capacity loss when optimizating power plants with dry cooling towers. A solution for the problem of losing generation capability by a power plant due to the use of a dry cooling tower is to supplement the dry tower during the hours of peak ambient temperatures by a wet tower. A separate wet/dry cooling tower system with series tower arrangement was considered in this study, and proved to be an economic choice over all-dry cooling where some water is available but supplies are insufficient for a totally evaporative cooling tower

  15. Environmental Health Disparities in Housing

    Science.gov (United States)

    2011-01-01

    The physical infrastructure and housing make human interaction possible and provide shelter. How well that infrastructure performs and which groups it serves have important implications for social equity and health. Populations in inadequate housing are more likely to have environmental diseases and injuries. Substantial disparities in housing have remained largely unchanged. Approximately 2.6 million (7.5%) non-Hispanic Blacks and 5.9 million Whites (2.8%) live in substandard housing. Segregation, lack of housing mobility, and homelessness are all associated with adverse health outcomes. Yet the experience with childhood lead poisoning in the United States has shown that housing-related disparities can be reduced. Effective interventions should be implemented to reduce environmental health disparities related to housing. PMID:21551378

  16. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  17. 24 CFR 983.52 - Housing type.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Housing type. 983.52 Section 983.52 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued) OFFICE OF ASSISTANT SECRETARY FOR PUBLIC AND INDIAN HOUSING, DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT PROJECT-BASED...

  18. Cooling of gas turbines IX : cooling effects from use of ceramic coatings on water-cooled turbine blades

    Science.gov (United States)

    Brown, W Byron; Livingood, John N B

    1948-01-01

    The hottest part of a turbine blade is likely to be the trailing portion. When the blades are cooled and when water is used as the coolant, the cooling passages are placed as close as possible to the trailing edge in order to cool this portion. In some cases, however, the trailing portion of the blade is so narrow, for aerodynamic reasons, that water passages cannot be located very near the trailing edge. Because ceramic coatings offer the possibility of protection for the trailing part of such narrow blades, a theoretical study has been made of the cooling effect of a ceramic coating on: (1) the blade-metal temperature when the gas temperature is unchanged, and (2) the gas temperature when the metal temperature is unchanged. Comparison is also made between the changes in the blade or gas temperatures produced by ceramic coatings and the changes produced by moving the cooling passages nearer the trailing edge. This comparison was made to provide a standard for evaluating the gains obtainable with ceramic coatings as compared to those obtainable by constructing the turbine blade in such a manner that water passages could be located very near the trailing edge.

  19. Dutch house price fundamentals

    NARCIS (Netherlands)

    Haffner, M.E.A.; de Vries, P.

    2009-01-01

    This paper discusses house price developments in the Netherlands, specifically focussing on the question whether current house prices in the Dutch owner-occupied market are likely to decrease. We analyse three aspects of the question based on a literature review: (1) whether there is a house price

  20. Impacts of the Weatherization Assistance Program in fuel-oil heated houses

    Energy Technology Data Exchange (ETDEWEB)

    Levins, W.P.; Ternes, M.P.

    1994-10-01

    In 1990, the US Department of Energy (DOE) initiated a national evaluation of its lowincome Weatherization Assistance Program. This report, which is one of five parts of that evaluation, evaluates the energy savings and cost-effectiveness of the Program as it had been applied to single-family houses heated primarily by fuel-oil. The study was based upon a representative sample (41 local weatherization agencies, 222 weatherized and 115 control houses) from the nine northeastern states during 1991 and 1992 program years. Dwelling-specific and agency-level data on measures installed, costs, and service delivery procedures were collected from the sampled agencies. Space-heating fuel-oil consumption, indoor temperature, and outdoor temperature were monitored at each house. Dwelling characteristics, air-leakage measurements, space-heating system steady-state efficiency measurements, safety inspections, and occupant questionnaires were also collected or performed at each monitored house. We estimate that the Program weatherized a total of 23,400 single-family fuel-oil heated houses in the nine northeastern states during program years 1991 and 1992. Annual fuel-oil savings were calculated using regression techniques to normalize the savings to standard weather conditions. For the northeast region, annual net fuel-oil savings averaged 160 gallons per house, or 17.7% of pre-weatherization consumption. Although indoor temperatures changed in individual houses following weatherization, there was no average change and no significant difference as compared to the control houses; thus, there was no overall indoor temperature takeback effect influencing fuel-oil savings. The weatherization work was performed cost effectively in these houses from the Program perspective, which included both installation costs and overhead and management costs but did not include non-energy benefits (such as employment and environmental).