WorldWideScience

Sample records for total hip bone

  1. Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs

    DEFF Research Database (Denmark)

    Christiansen, Janus D.; Laursen, Mogens B; Ejaz, Ashir

    2018-01-01

    INTRODUCTION: The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric). METHODS......: In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline......% (95% confidence interval [CI], 4-16; p = 0.003) and 8% (95% CI, 1-15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23-69) to 93 (55...

  2. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, Nicolaas Jacobus Joseph; van Susante, J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  3. Distribution of polyethylene wear debris and bone particles in granuloma tissue around total hip joint replacements

    Czech Academy of Sciences Publication Activity Database

    Zolotarevova, E.; Lapčíková, Monika; Šlouf, Miroslav; Entlicher, G.; Pokorný, D.; Veselý, F.; Sosna, A.

    2008-01-01

    Roč. 18, č. 2 (2008), s. 173-174 ISSN 1120-7000. [Domestic Meeting of the European Hip Society /8./. 11.06.2008-13.06.2008, Madrid] R&D Projects: GA MŠk 2B06096 Institutional research plan: CEZ:AV0Z40500505 Keywords : wear debris * bone particles * total hip joint replacement Subject RIV: CD - Macromolecular Chemistry www. hip -int.com

  4. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  5. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    Science.gov (United States)

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no

  6. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    Science.gov (United States)

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  7. Fate of bulk auto grafts in uncemented total hip arthroplasty: Evaluation by bone scintigraphy

    International Nuclear Information System (INIS)

    Simsek, A.; Cila, E.; Sener, E.; Senkoylu, A.; Sipahioglu, S.; Atasever, T.; Akdemir, Ozgur

    2006-01-01

    Objective was to review short term results of uncemented cup implantation and the fate of bulk femoral head autografts in patients with acetabular bone deficiency due to dysplasia of the hip. We used bone scintigraphy to assess the viability of the grafts. We treated 19 hip joints of 17 patients with osteoarthritis due to developmental dysplasia of the hip with uncemented total hip arthroplasty between 1997-2003 in the Department of Orthopedics and Traumatology, Gazi University, Ankara, Turkey. The average age was 49.1 (31-72 years), and the average follow up period was 36 months. We used femoral head autografts to reconstruct superolateral segmental deficiencies of the acetabuli. We evaluated the patients clinically and radiologically to assess acetabular loosening, and we used three-phase bone scintigraphy to evaluate the viability of the autograft.There was no acetabular component revision throughout the follow up period. There was no radiological evidence of graft resorption or graft displacement in any of the patients. In bone scintigraphy, we observed hyperemia in the blood pool phase, and the osteoblastic activity of the bone graft was at the level of the neighboring iliac bone. The application of a non-cemented acetabular component with femoral autograft in superolateral acetabulum deficiency increases the stability of the implant and increases the bone stock. It is not easy to evaluate the viability of the graft by the use of radiological methods. Bone scintigraphy gives sufficient information about the viability of the graft as a non-invasive method. (author)

  8. TOTAL HIP ARTHROPLASTY IN CHILDREN WHO HAVE UNDERGONE ARTHROPLASTY WITH DEMINERALIZED BONE-CARTILAGE ALLOCUPS

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  9. Total hip arthroplasty in children who have undergone arthroplasty with demineralized bone-cartilage allocups

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    Full Text Available Introduction. Treating children with degenerative dystrophic diseases of the hip joint has become one of the most acute problems in contemporary orthopedics. Until recently, we performed arthroplasty by demineralized bone-cartilage allocups (DBCA in the Clinic of the Hip Joint Pathology of the Turner Scientific and Research Institute for Children’s Orthopedics for patients showing clinical and radiological signs of irreversible destruction of the hip joint; we carried out this procedure to preserve the function of the lower limb. However, over the last 8 years, we have changed our protocol for children older than 12 years of age and have replaced DBCA with total hip replacement. In a number of cases, total hip replacement was performed after a previous intervention involving arthroplasty with DBCA. Objective. To determine the technical peculiarities of total hip replacement after a previous intervention involving arthroplasty with DBCA. Material and methods. We analyzed the results of treatment involving various types of hip pathology in 13 children (100% aged between 15 and 16 years [8 girls (61.5% and 5 boys (38.5%]. The medical histories of all 13 children (100% showed repeated operations on the hip joint, ultimately resulting in arthroplasty with DBCA. All 13 children (100% underwent a total hip replacement. Upon hip replacement, all 13 patients (100% showed a pronounced thinning and hardening of the edges and the bottom of the acetabulum, which created some difficulties in the process of acetabular component implantation. The transformation of DBCA was not evident in any of the 13 cases (100%. Results. During the observation period of 3–5 years following total hip arthroplasty, all 13 cases (100% showed recovery in the range of motion and absence of pain. An important criterion for evaluating the quality of care was the complete social and domestic adaptation of all 13 children (100% during the period from 6 to 9 months following total

  10. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  11. CT-based quantification of bone stock in large head metal-on-metal unilateral total hip replacements

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Slouwerhof, Inge; van Lingen, Christiaan; Pakvis, Dean F. M.; van Dalen, Jorn A.; Edens, Mireille A.; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    To explore ipsilateral and contralateral acetabular roof bone stock density in unilateral large head MoM THA whether there is a significant lower acetabular bone stock in the hip with a metal-on-metal (MoM) total hip replacement compared to the contralateral side. Second part of this study is to

  12. Use of postoperative irradiation for the prevention of heterotopic bone formation after total hip replacement

    International Nuclear Information System (INIS)

    Sylvester, J.E.; Greenberg, P.; Selch, M.T.; Thomas, B.J.; Amstutz, H.

    1988-01-01

    Formation of heterotopic bone (HTB) following total hip replacement may partially or completely ankylose the joint space, causing pain and/or limiting the range of motion. Patients at high risk for formation of HTB postoperatively include those with previous HTB formation, heterotopic osteoarthritis, and active rheumatoid spondylitis. Patients in these high risk groups have a 63-69% incidence of post-operative HTB formation, usually seen radiographically by 2 months post-operation. From 1980-1986 twenty-nine hips in 28 consecutively treated patients were irradiated post-operatively at the UCLA Center for the Health Sciences. The indication for irradiation was documented HTB formation previously in 26 of the 27 hips presented below. From 1980-1982 patients received 20 Gray (Gy) in 2 Gy fractions; from 1982-1986 the dose was reduced to 10 Gy in 2 Gy fractions. Twenty-seven hips in 26 patients completed therapy and were available for evaluation, with a minimum of 2 month follow-up, and a median follow-up of 12 months. Three of 27 hips developed significant HTB (Brooker grade III or IV) post-operatively, whereas 5 of 27 hips developed minor, nonsymptomatic HTB (Brooker grade I). When irradiation was begun by postoperative day 4, 0 of 17 hips formed significant HTB. If irradiation began after post-operative day 4, 3 of 10 hips formed significant HTB (Brooker grade III or IV). These 3 hips received doses of 10 Gy in one hip and 20 Gy in the other 2 hips. There were no differences in the incidence or severity of side effects in the 10 Gy vs. the 20 Gy treatment groups. Eighteen hips received 10 Gy, 8 hips 20 Gy and, 1 hip 12 Gy. In conclusion, 10 Gy in 5 fractions appears as effective as 20 Gy in 10 fractions at preventing post-operative formation of HTB. For optimal results, treatment should begin as early as possible prior to post-operative day 4

  13. Instrumental and laboratory assessment of stressful remodelling processes in bone tissue at total hip replacement

    Directory of Open Access Journals (Sweden)

    E.V. Karjakina

    2010-06-01

    Full Text Available Research objective is to estimate stressful remodelling features of bone tissue according to the densitometry data and to the level of biochemical markers of bone resorption and formation in total hip replacement (THR. Bone tissue mineral density (BTMD, condition of calcium-phosphoric metabolism and biochemical markers of bone formation (osteocalcin and bone isoenzyme of alkaline phosphatase and resorption (С-terminal bodypeptide of the I type collagen have been determined in 52 patients with coxarthrosis of ll-lll stages with marked joint dysfunction before and after THR. The control group included 24 donors. The data were considered to be reliable when the probability index was р<0,05. The reliable (р<0,05 change of BTMD was determined only in 3-6 months after the operation, whereas the change of biochemical markers of remodeling had already been done after 1,5-3 months, allowing to define the group of patients with obvious negative bone balance: strong predominance of resorption processes without compensation of the subsequent adequate osteogenesis, that subsequently could lead to significant bone tissue deficiency in the area adjacent to the endoprosthesis. Changes of indices of calcium-phosphoric metabolism were not certain during the investigation term. ln conclusion it is to state that biochemical markers of remodeling in comparison with BTMD allow to estimate objectively features of adaptive bone tissue remodeling after THR in earlier periods and to define group of patients with sharp intensification of metabolism and obvious negative bone balance

  14. The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty.

    Science.gov (United States)

    Oonishi, Hiroyuki; Akiyama, Haruhiko; Takemoto, Mitsuru; Kawai, Toshiyuki; Yamamoto, Koji; Yamamuro, Takao; Oonishi, Hironobu; Nakamura, Takashi

    2011-10-01

    The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone cements retrieved from patients undergoing revision THA. CMW1 cements were retrieved from 14 patients who underwent acetabular revision because of aseptic loosening. The time in vivo before revision was 7-30 years. The bending properties of the retrieved bone cement were assessed using the three-point bending method. The molecular weight and chemical structure were analyzed by gel permeation chromatography and Fourier-transform infrared spectroscopy. The porosity of the bone cements was evaluated by 3-D microcomputer tomography. The bending strength decreased with increasing time in vivo and depended on the density of the bone cement, which we assume to be determined by the porosity. There was no correlation between molecular weight and time in vivo. The infrared spectra were similar in the retrieved cements and in the control CMW1 cements. Our results indicate that polymer chain scission and significant hydrolysis do not occur in CMW1 cement after implantation in vivo, even in the long term. CMW1 cement was stable through long-term implantation and functional loading.

  15. Gait analysis, bone and muscle density assessment for patients undergoing total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benedikt Magnússon

    2012-12-01

    Full Text Available Total hip arthroplasty (THA is performed with or without the use of bone cement. Facing the lack of reliable clinical guidelines on decision making whether a patient should receive THA with or without bone cement, a joint clinical and engineering approach is proposed here with the objective to assess patient recovery developing monitoring techniques based on gait analysis, measurements of bone mineral density and structural and functional changes of quadriceps muscles. A clinical trial was conducted with 36 volunteer patients that were undergoing THA surgery for the first time: 18 receiving cemented implant and 18 receiving non-cemented implant. The patients are scanned with Computer Tomographic (CT modality prior-, immediately- and 12 months post-surgery. The CT data are further processed to segment muscles and bones for calculating bone mineral density (BMD. Quadriceps muscle density Hounsfield (HU based value is calculated from the segmented file on healthy and operated leg before and after THA surgery. Furthermore clinical assessment is performed using gait analysis technologies such as a sensing carpet, wireless electrodes and video. Patients undergo these measurements prior-, 6 weeks post - and 52 weeks post-surgery. The preliminary results indicate computational tools and methods that are able to quantitatively analyze patient’s condition pre and post-surgery: The spatial parameters such as step length and stride length increase 6 weeks post op in the patient group receiving cemented implant while the angle in the toe in/out parameter decrease in both patient groups.

  16. EXPERIMENTAL RESEARCH OF REGENERATIVE FEATURES IN BONE TISSUES AROUND IMPLANTS AFTER ONE-STAGE BILATERAL TOTAL HIP REPLACEMENT

    Directory of Open Access Journals (Sweden)

    V. M. Mashkov

    2012-01-01

    Full Text Available Objective: to research the specific features of regenerative processes of bone tissue around implants after one-stage bilateral total hip replacement in experiment. Material and methods: 27 total hip replacement operations have been performed in 18 rabbits of breed "chinchilla" to which bipolar femoral endoprosthesis made of titanic alloy PT-38, one type-size, with friction pair metal-on-metal and neck-shaft angle 165 degrees have been implanted: total unilateral hip replacement operations have been performed in 9 animals (control group, one-stage bilateral total hip replacement operations have been performed in 9 animals (experimental group. During research they have been on radiological and clinical checking-up. After the experiment the animals had histological tests of the tissues around endoprosthesis components. Results and conclusions: After one-stage bilateral total hip replacement in early terms of research more expressed changes of bone tissue in the form of its thinning and decompaction were found around implants. One-stage bilateral total hip replacement did not essentially influence on the speed of osteogenesis around endoprothesis components in comparison with unilateral total hip replacement, so in late terms of observation in both groups the fixing of endoprothesis components did not differ.

  17. Bone Metabolism after Total Hip Revision Surgery with Impacted Grafting: Evaluation using H215O and [18F]fluoride PET; A Pilot Study

    NARCIS (Netherlands)

    Temmerman, Olivier; Raijmakers, Pieter; Heyligers, Ide; Comans, Emile; Lubberink, Mark; Teule, Gerrit; Lammertsma, Adriaan

    2008-01-01

    Purpose: To evaluate bone blood flow and bone formation in patients after total hip revision surgery with impacted bone grafting using H2 15O and [18F]fluoride positron emission tomography (PET). Procedures: To asses bone blood flow and bone metabolism in bone allograft after impaction grafting,

  18. A prospective randomised study of periprosthetic femoral bone remodeling using four different bearings in hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Zerahn, Bo; Borgwardt, Lotte; Ribel-Madsen, Søren

    2011-01-01

    in all Gruen zones with the largest declines in group D. BMD changes in Gruen zones 1, 2, 3, 6, and 7 correlated with height, and body weight. Advanced age was associated with an increase in bone loss in Gruen zones 1, 2, 3, 6, and 7. A large stem size was associated with a decline in BMD in Gruen zones......Abstract: We performed a study to assess whether different bearing materials have an impact on femoral bone remodeling within the first four years after a hybrid total hip arthroplasty. 205 of 300 patients were available for 4 years follow-up after being randomly allocated to four prosthetic...... 1, 6, and 7.Bone remodeling after total hip arthroplasty may depend on the composition of bearing materials, but age, height, weight, and stem size are also related to changes in BMD....

  19. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review.

    Science.gov (United States)

    Yan, Shuang G; Weber, Patrick; Steinbrück, Arnd; Hua, Xingyi; Jansson, Volkmar; Schmidutz, Florian

    2017-11-27

    Short-stem hip arthroplasty (SHA) was designed to preserve bone stock and provide an improved load transfer. To gain more evidence regarding the load transfer, this review analysed the periprosthetic bone remodelling of SHA in comparison to standard hip arthroplasty (THA). PubMed and ScienceDirect were screened to extract dual-energy X-ray absorptiometry (DXA) studies evaluating the periprosthetic bone remodelling of SHA and two proven THA designs. From the studies included, the postoperative change in periprosthetic bone mineral density (BMD) after one year and the trend over two years was determined. Fifteen studies with four SHAs (CFP, Metha, Nanos, Fitmore) and two THAs (CLS and Bicontact) designs were included. All SHA and THA stems revealed an initial decrease at the calcar and major trochanter (Gruen 1 and 7) with the Metha, Nanos and Fitmore showing a smaller and more balanced remodelling compared to THA. The pattern after one year and the trend over two years argue for a methaphyseal anchorage of the Metha and Nanos, whereas the Fitmore and CFP seem to anchor metha-diaphyseal. Clearly different pattern of bone remodelling were observed between all four SHAs. Periprosthetic bone remodelling is also present in SHA, with the main bone reduction observed proximally. However, certain SHA stems show a more balanced remodelling compared to THA, arguing for a favourable load transfer. Also, the femoral length where bone remodelling occurs is clearly shorter in SHA. As distinctively different pattern between the SHA designs were observed, they should not be judged as a single implant group.

  20. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

    Science.gov (United States)

    Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan

    2015-10-01

    Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.

  1. Adaptive bone remodeling and biomechanical design considerations : for noncemented total hip arthroplasty

    NARCIS (Netherlands)

    Huiskes, H.W.J.; Weinans, H.; Dalstra, M.

    1989-01-01

    Clinical problems with noncemented total hip arthroplasty (THA) stems, directly or indirectly related to load transfer, include mid-thigh pain due to relative (micro) motions or excessive endosteal interface stresses, subsidence and loosening due to inadequate primary stability and fit, and proximal

  2. Numerical analysis of the biomechanical complications accompanying the total hip replacement with NANOS-Prosthetic: bone remodelling and prosthesis migration

    Directory of Open Access Journals (Sweden)

    Almohallami A.

    2015-09-01

    Full Text Available Aseptic loosening of the prosthesis is still a problem in artificial joint implants. The ýloosening can be caused by the resorption of the bone surrounding ýthe prosthesis according to stress shielding. A numerical model was developed and validated by means of DEXA-studies in order to ýanalyse the bone remodelling process in the periprosthetic bone. A total loss of about 3.7% of the bone density in the periprosthetic Femur with NANOS is computed. The bone remodelling calculation was validated by means of a DEXA-study with a 3-years-follow-up. The model was further developed in order to be able to calculate and consider the migration of the implants. This method was applied on the ýNANOS-implant with a computed total migration of about 0.43 mm. These calculations showed good results in comparison with a 2-year-follow-up clinical study, whereby a RSA-method was used to determine the stem migration in the bone. In order to ýstudy the mutual influence between the implant migration and the hip contact forces ý, a software is developed by our scientific group to couple a multi body simulation (MBS of human lower limps with the FEA of the periprosthetic Femur.

  3. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  4. Frequency of Osteoporosis and Osteopenia According To Bone Mineral Density of Proximal Femur Subregions in Normal and Osteopenic Postmenopausal Women With Respect to Total Hip Bone

    Directory of Open Access Journals (Sweden)

    Murat Ersöz

    2002-09-01

    Full Text Available In this study 29 normal (mean age: 65.6 ± 5.1 years and 33 osteopenic (mean age: 67.6 ± 4.9 years postmenopausal women according to total bone mineral density (BMD of the hip were evaluated for BMD values of subregions of proximal femur. The percentages for osteoporosis and osteopenia with respect to subregions were 13.8% and 58.6% for femoral neck and 20.7% and 41.4% for Ward’s triangle in normal group. In trochanteric and intertrochanteric measurements there were no T scores below –2.5 but 17.2% of the subjects were osteopenic with regard to trochanteric and 6.9% were osteopenic due to intertrochanteric BMD values. The percentages for osteoporosis and osteopenia with respect to subregion measurements were 57.6% and 42.4% for femoral neck, 60.6% and 36.4% for Ward’s triangle, 3% and 78.8% for trochanteric, 9.1% and 87.9% for intertrochanteric regions in osteopenic group according to total hip values. Knowing that hip fracture risk is increasing 2-3 fold for 1 standart deviation decrease from the young adult mean value for all subregions and knowing the relation between cervical hip fractures and BMD values of Ward’s triangle and femoral neck and the relation between intertrochanteric fractures and trochanteric BMD values, it is recommended to evaluate the BMD values of subregions of the hip besides the total hip values in daily practice.

  5. Total hip replacement with a superolateral bone graft for osteoarthritis secondary to dysplasia: a long-term follow-up

    NARCIS (Netherlands)

    de Jong, P. T.; Haverkamp, D.; van der Vis, H. M.; Marti, R. K.

    2006-01-01

    We evaluated the long-term results of 116 total hip replacements with a superolateral shelfplasty in 102 patients with osteoarthritis secondary to developmental dysplasia of the hip. After a mean follow-up of 19.5 years (11.5 to 26.0), 14 acetabular components (12%) had been revised. The cumulative

  6. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  7. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  8. A novel technique for impaction bone grafting in acetabular reconstruction of revision total hip arthroplasty using an ex vivo compaction device

    International Nuclear Information System (INIS)

    Akiyama, Haruhiko; Takemoto, Mitsuru; Morishima, Takkan

    2011-01-01

    Impaction bone grafting allows restoration of the acetabular bone stock in revision hip arthroplasty. The success of this technique depends largely on achieving adequate initial stability of the component. To obtain well-compacted, well-graded allograft aggregates, we developed an ex vivo compaction device to apply it in revision total hip arthroplasty on the acetabular side, and characterized mechanical properties and putative osteoconductivity of allograft aggregates. Morselized allograft bone chips were compacted ex vivo using the creep technique and subsequent impaction technique to form the bone aggregates. Impaction allograft reconstruction of the acetabulum using an ex vivo compaction device was performed on eight hips. The mechanical properties and three-dimensional micro-CT-based structural characteristics of the bone aggregates were investigated. In clinical practice, this technique offered good reproducibility in reconstructing the cavity and the segmental defects of the acetabulum, with no migration and no loosening of the component. In vitro analysis showed that the aggregates generated from 25 g fresh-frozen bone chips gained compression stiffness of 13.5-15.4 MPa under uniaxial consolidation strain. The recoil of the aggregates after compaction was 2.6-3.9%. The compression stiffness and the recoil did not differ significantly from those measured using a variety of proportions of large- and small-sized bone chips. Micro-CT-based structural analysis revealed average pore sizes of 268-299 μm and average throat diameter of pores in the bone aggregates of more than 100 μm. These sizes are desirable for osteoconduction, although large interconnected pores of more than 500 μm were detectable in association with the proportion of large-sized bone chips. Cement penetration into the aggregates was related to the proportion of large-sized bone chips. This study introduces the value of an ex vivo compaction device in bone graft compaction in clinical

  9. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Science.gov (United States)

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  10. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Directory of Open Access Journals (Sweden)

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  11. Patterns of bone tracer uptake on SPECT-CT in symptomatic and asymptomatic patients with primary total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, Thierry; Hirschmann, Michael T. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); University of Basel, Basel (Switzerland); Schiapparelli, Filippo-Franco; Rotigliano, Niccolo [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Rasch, Helmut [Kantonsspital Baselland, Institute of Radiology and Nuclear Medicine, Bruderholz (Switzerland); Amsler, Felix [Amsler Consulting, Basel (Switzerland)

    2018-02-15

    The primary purpose of this study was to compare bone tracer uptake (BTU) on SPECT/CT in symptomatic and asymptomatic total hip arthroplasty (THA) and identify a possible relationship between BTU patterns and patient's symptoms. The secondary purpose was to investigate if the fixation methods (cemented versus uncemented) lead to different BTU patterns. A total of 58 THAs, 31 symptomatic (group S) and 27 asymptomatic (group AS), were prospectively collected and retrospectively analyzed. All symptomatic patients underwent standardized detailed history, clinical examination, radiographs and 99mTc-HDP SPECT/CT. BTU in SPECT/CT was quantified in three dimensions and anatomically localized in a scheme of quadrants and levels using a customized previously validated software. T tests were used on both quadrants and levels inside and between groups. A Pearson correlation was performed for BTU within the quadrants. An area under receiver operating characteristic curves was drawn in order to find a BTU value that could differentiate the two groups. Within the groups, patients with cemented and uncemented stems were compared for influences on BTU intensity. The causes of pain were identified in 61% of the patients. The most common problem was aseptic loosening (n = 12). In group AS, levels 1, 2 and 5 had similar BTUs. BTUs in these levels were significantly higher than in level 3, 4 and 6. In group S, no significant differences were seen in terms of BTU in level 1-5. However, BTU here was significantly higher than at level 6 (p < 0.001). In both groups, level 1, the superior, had a significantly higher BTU than level 2 (group AS p < 0.01, group S p < 0.05). Comparing the BTU of the two groups among levels, significant differences were found for level 4, level 5 and the entire stem areas (p < 0.05). The ROC curve calculated on the whole stem allowed identification of a BTU ratio of 3.1 that separated the 92.6% patients of group AS with BTU < 3.1 from the 54.8% of patients

  12. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  13. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty....... Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  14. Radiological evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Tehranzadeh, J.; Schneider, R.; Freiberger, R.H.

    1981-01-01

    Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99 mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated

  15. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  16. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  17. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up.

    Science.gov (United States)

    Flivik, G; Kristiansson, I; Ryd, L

    2015-01-01

    We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement-bone interface in order to maximise acetabular component stability and longevity. ©2015 The British Editorial Society of Bone & Joint Surgery.

  18. Instability after total hip arthroplasty

    Science.gov (United States)

    Werner, Brian C; Brown, Thomas E

    2012-01-01

    Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Non-operative management is often successful if the components are well-fixed and correctly positioned in the absence of neurocognitive disorders. If conservative management fails, surgical options include revision of malpositioned components; exchange of modular components such as the femoral head and acetabular liner; bipolar arthroplasty; tripolar arthroplasty; use of a larger femoral head; use of a constrained liner; soft tissue reinforcement and advancement of the greater trochanter. PMID:22919568

  19. The utility of the Philips SRI-100 real time portal imaging device in a case of postoperative irradiation for prevention of heterotopic bone formation following total hip replacement

    International Nuclear Information System (INIS)

    Kiffer, J.D.; Quong, G.; Lawlor, M.; Schumer, W.; Aitken, L.; Wallace, A.

    1994-01-01

    The new Radiation Oncology Department at the Heidelberg Repatriation Hospital in Melbourne, Australia commenced operation in June 1992. As part of quality control the Philips SL-15 linear accelerator was fitted with the Philips SRI-100 Real Time Portal Imaging Device (RTPID), the first such apparatus in Australia. One of its major advantages over older systems is its ability to provide a permanent hard copy of the image of the field treated. The computer image can be immediately manipulated and enhanced on the screen (with respect to such qualities as brightness and contrast) prior to the printing of the hard copy. This is a significant improvement over the more cumbersome older port films that required developing time, without any pre-assessment of the image quality. The utility of the Philips SRI-100 RTPID is demonstrated in the case of a patient irradiated soon after total hip replacement, as prophylaxis against heterotopic bone formation (HBF). The rapidity and quality of image production is a major advantage in these patients where post operative pain may result in positional change between film exposure and image production. Extremely accurate shielding block position is essential to shield the prosthesis(and allow bone ingrowth for fixation) whilst avoiding inadvertent shielding of the areas at risk for HBF. A review of the literature on this topic is provided. 14 refs., 4 figs

  20. Primary extra-cranial meningioma following total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, T.J.; Beggs, I. [Royal Infirmary, Department of Radiology, Edinburgh (United Kingdom); Patton, J.T.; Porter, D. [Royal Infirmary, Department of Orthopaedics, Edinburgh (United Kingdom); Salter, D.M.; Al-Nafussi, A. [Royal Infirmary, Department of Pathology, Edinburgh (United Kingdom)

    2009-01-15

    A 61-year-old man presented with pain at the left hip and decreased mobility 10 years after total hip replacement. Imaging demonstrated a large destructive expansile mass adjacent to the prosthesis. Histological analysis confirmed the presence of an extra-cranial meningioma. Primary tumours after total hip replacement are rare and include soft tissue sarcomas, bone sarcomas and lymphomas. To our knowledge, no previous cases of primary extracranial meningioma have been identified. The imaging features, histology, pathogenesis and differential diagnosis are discussed. (orig.)

  1. Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee

    2017-08-01

    Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.

  2. Effect of zoledronic acid on reducing femoral bone mineral density loss following total hip arthroplasty: A meta-analysis from randomized controlled trails.

    Science.gov (United States)

    Gao, Jian; Gao, Chong; Li, Hui; Wang, Guo-Sheng; Xu, Chang; Ran, Jian

    2017-11-01

    This meta-analysis aimed to assess the efficiency of intravenous administration of zoledronic acid on reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty (THA). A systematic search was performed in Medline (1966-2017.07.31), PubMed (1966-2017.07.31), Embase (1980-2017.07.31), ScienceDirect (1985-2017.07.31) and the Cochrane Library (1966-2017.07.31). Fixed/random effect model was used according to the heterogeneity tested by I 2 statistic. Sensitivity analysis was conducted and publication bias was assessed. Meta-analysis was performed using Stata 11.0 software. Four studies including 185 patients met the inclusion criteria. The present meta-analysis indicated that there were significant differences between groups in terms of periprosthetic bone mineral density in Gruen zone 1 (SMD = 0.752, 95% CI: 0.454 to 1.051, P = 0.000), 2 (SMD = 0.524, 95% CI: 0.230 to 0.819, P = 0.000), 4 (SMD = 0.400, 95% CI: 0.107 to 0.693, P = 0.008), 6 (SMD = 0.893, 95% CI: 0.588 to 1.198, P = 0.000) and 7 (SMD = 0.988, 95% CI: 0.677 to 1.300, P = 0.000). Intravenous administration of zoledronic acid could significantly reduce periprosthetic bone mineral density loss (Gruen zone 1, 2, 4, 6 and 7) after THA. In addition, no severe adverse events were identified. High-quality RCTs with large sample size were still required. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  3. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  4. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  5. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    Science.gov (United States)

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle cup-host bone fixation, especially when the cup-CE angle is small, such as cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  6. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

    Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position....

  7. Total hip arthroplasty for giant cell tumour.

    Directory of Open Access Journals (Sweden)

    Kulkarni S

    1996-07-01

    Full Text Available A 32 month follow up of an uncommon case of a Giant Cell Tumour affecting the proximal end of femur is presented. Following a wide excision, the hip was reconstructed using Charnley type of low friction total hip arthroplasty. At a 32 month review, there was no recurrence and the function was good.

  8. Total hip reconstruction in acetabular dysplasia : a finite element study

    NARCIS (Netherlands)

    Schüller, H.M.; Dalstra, M.; Huiskes, H.W.J.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  9. Primary total hip replacement versus hip resurfacing - hospital considerations.

    Science.gov (United States)

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  10. Prevention of heterotopic bone formation with early post operative irradiation in high risk patients undergoing total hip arthroplasty: comparison of 10.00 Gy vs 20.00 Gy schedules

    International Nuclear Information System (INIS)

    Anthony, P.; Keys, H.; Evarts, C.M.; Rubin, P.; Lush, C.

    1987-01-01

    Prior studies have demonstrated the effectiveness of postoperative radiation therapy (RT) to the hip area following total hip replacement (THR) surgery in preventing the development of heterotopic bone formation in patients considered to be at high risk for development of this complication. Previously, patients received 20.00 Gy in 10 fractions (fx) over 2 weeks, beginning as soon postop as medically feasible (usually post-op day 2). In an effort to reduce hospital stay and risk of secondary malignancy, a prospective treatment program was initiated April 1982 using a reduced dose of 10.00 Gy in 5 fx over 5-7 days. As of February 1984, 46 consecutive hips determined to be at high risk were treated with this reduced dose. Prior studies have demonstrated that heterotopic bone is always radiographically evident by 8 weeks. Of the 46 hips, 41 had been evaluated with the minimum required 8 week follow-up X ray. Twenty-five of these hips, 61%, had a mean long term follow-up of 12 months. It historical control group, consisting of 54 consecutive high risk post-THR's, was shown to have a 68.5% incidence of heterotopic bone. The 20.00 Gy group, when RT was started by post-op day 5, demonstrated a 3.2% incidence, compared to 4.9% in the 10.00 Gy group. Complication rates were also comparable in the two RT groups, 19.4% and 7.3% respectively; 10.00 Gy is apparently as effective as 20.00 Gy in preventing heterotopic bone formation in high risk post-THR patients

  11. Immunological Responses to Total Hip Arthroplasty.

    Science.gov (United States)

    Man, Kenny; Jiang, Lin-Hua; Foster, Richard; Yang, Xuebin B

    2017-08-01

    The use of total hip arthroplasties (THA) has been continuously rising to meet the demands of the increasingly ageing population. To date, this procedure has been highly successful in relieving pain and restoring the functionality of patients' joints, and has significantly improved their quality of life. However, these implants are expected to eventually fail after 15-25 years in situ due to slow progressive inflammatory responses at the bone-implant interface. Such inflammatory responses are primarily mediated by immune cells such as macrophages, triggered by implant wear particles. As a result, aseptic loosening is the main cause for revision surgery over the mid and long-term and is responsible for more than 70% of hip revisions. In some patients with a metal-on-metal (MoM) implant, metallic implant wear particles can give rise to metal sensitivity. Therefore, engineering biomaterials, which are immunologically inert or support the healing process, require an in-depth understanding of the host inflammatory and wound-healing response to implanted materials. This review discusses the immunological response initiated by biomaterials extensively used in THA, ultra-high-molecular-weight polyethylene (UHMWPE), cobalt chromium (CoCr), and alumina ceramics. The biological responses of these biomaterials in bulk and particulate forms are also discussed. In conclusion, the immunological responses to bulk and particulate biomaterials vary greatly depending on the implant material types, the size of particulate and its volume, and where the response to bulk forms of differing biomaterials are relatively acute and similar, while wear particles can initiate a variety of responses such as osteolysis, metal sensitivity, and so on.

  12. Is cortical bone hip? What determines cortical bone properties?

    Science.gov (United States)

    Epstein, Sol

    2007-07-01

    Increased bone turnover may produce a disturbance in bone structure which may result in fracture. In cortical bone, both reduction in turnover and increase in hip bone mineral density (BMD) may be necessary to decrease hip fracture risk and may require relatively greater proportionate changes than for trabecular bone. It should also be noted that increased porosity produces disproportionate reduction in bone strength, and studies have shown that increased cortical porosity and decreased cortical thickness are associated with hip fracture. Continued studies for determining the causes of bone strength and deterioration show distinct promise. Osteocyte viability has been observed to be an indicator of bone strength, with viability as the result of maintaining physiological levels of loading and osteocyte apoptosis as the result of a decrease in loading. Osteocyte apoptosis and decrease are major factors in the bone loss and fracture associated with aging. Both the osteocyte and periosteal cell layer are assuming greater importance in the process of maintaining skeletal integrity as our knowledge of these cells expand, as well being a target for pharmacological agents to reduce fracture especially in cortical bone. The bisphosphonate alendronate has been seen to have a positive effect on cortical bone by allowing customary periosteal growth, while reducing the rate of endocortical bone remodeling and slowing bone loss from the endocortical surface. Risedronate treatment effects were attributed to decrease in bone resorption and thus a decrease in fracture risk. Ibandronate has been seen to increase BMD as the spine and femur as well as a reduced incidence of new vertebral fractures and non vertebral on subset post hoc analysis. And treatment with the anabolic agent PTH(1-34) documented modeling and remodelling of quiescent and active bone surfaces. Receptor activator of nuclear factor kappa B ligand (RANKL) plays a key role in bone destruction, and the human monoclonal

  13. The tribology of metal-on-metal total hip replacements.

    Science.gov (United States)

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  14. Radiological evaluation of failed total hip replacement

    International Nuclear Information System (INIS)

    Raspa, V.; Aldrovandi, S.; Pompei, G.

    1988-01-01

    The retrospective study of 50 operated cases of cemented total hip replacement and a review of the literature enabled the authors to define the radiological features of the above-mentioned condition. These features include one or more of the following signs: calcar reabsorption, lacunar erosions, modified relatioships between the prosthesis components, sepsis and loosening, periarticular calcifications dislocation and fracture of prosthesis components. Careful evaluation of these radiological features is extremely important for both an early diagnosis of failed total hip replacement and the choice of an adequate surgical treatment

  15. TOTAL HIP ARTHROPLASTY IN OSTEOPETROSIS – REPORT OF A CASE

    Directory of Open Access Journals (Sweden)

    Zmago Krajnc

    2004-04-01

    Full Text Available Background. Authors introduced a case of a 27-year men with osteopetrosis with hip arthrosis. He has an autosomal – dominant form of disease and he needed total hip arthroplasty. There are seven cases described in literature with developed hip arthrosis by osteopetrosis.Methods. TEP implantation represents the greates surgical challenge in this patients, especially creation of intramedullary canal in femur and implantation of the femoral stem because of the very dense and brittle bones. This article describes the operative technique used in the case involved. It proved to be a very good solution.Results. The patient was released from the hospital ten days after implantation of total hip endoprosthesis. Three months after the operation the patient started to walk without aid of canes, he had non pain, and his range of motion was almost normal.Conclusions. Severe coxarthrosis is a rare complication of osteopetrosis. Great care must be taken with implantation of total hip endoprosthesis, especially with preparation of medular canal. It was recommended hand drilling under x-rays to exercise maximal control because reaming can cause false root of stem and greater probability of fracture.

  16. TOTAL HIP REPLACEMENTS AT KIKUYU HOSPITAL, KENYA

    African Journals Online (AJOL)

    equipments, few trained personnel and the high cost of implants. It is mainly in the ..... function more affected than the sensory a day after. There was a foot drop. .... 60: Issue 2, 217-. 220. 13. NIH Consensus Development Panel on Total Hip.

  17. Usefulness of postoperative hip irradiation in the prevention of heterotopic bone formation in a high risk group of patients

    International Nuclear Information System (INIS)

    MacLennan, I.; Keys, H.M.; Evarts, C.M.; Rubin, P.

    1984-01-01

    Heterotopic ossification is a complication of total hip arthroplasty in 14 to 30% of patients. Significant functional impairment will occur in up to 28% of patients with ectopic bone. The high risk group includes those with preexisting heterotopic bone in either hip, those suffering from hypertrophic osteoarthritis or ankylosing spondylitis and patients who have had multiple procedures on the hip. Fifty-eight patients (67 hips) were irradiated after surgical removal of ectopic bone (53 hips) or received radiation prophylaxis of heterotopic ossification (14 hips). Ninety-five percent of patients had either no bone visible or insignificant amounts of ectopic bone visible on postoperative hip X-rays. Only 5% of patients showed significant persistence of ectopic bone. Postoperative hip function was dramatically improved compared to preoperative function in all patients treated. The importance of early commencement of irradiation is emphasized

  18. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  19. Sonographic findings after total hip arthroplasty: normal and complications

    International Nuclear Information System (INIS)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun

    2002-01-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred

  20. Sonographic findings after total hip arthroplasty: normal and complications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    2002-04-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred.

  1. Exercise therapy may postpone total hip replacement surgery in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Svege, Ida; Nordsletten, Lars; Fernandes, Linda

    2015-01-01

    Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown.......Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown....

  2. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  3. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  4. Total hip arthroplasty in patients with neuromuscular imbalance.

    Science.gov (United States)

    Konan, S; Duncan, C P

    2018-01-01

    Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation. In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival. Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication. Cite this article: Bone Joint J 2018;100-B(1 Supple A):17-21. ©2018 The British Editorial Society of Bone & Joint Surgery.

  5. Factors influencing initial cup stability in total hip arthroplasty.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Weight-bearing radiography in total hip replacement

    International Nuclear Information System (INIS)

    Turula, K.B.; Haajanen, J.; Friberg, O.; Lindholm, T.S.; Tallroth, K.

    1985-01-01

    Serial anteroposterior (AP) radiographs of the weight-bearing pelvis and hips were taken of 29 patients with total hip replacement (THR). For constant positioning the patient stands with straight knees on a board with a block between the heels. A U-shaped mercury level strapped to the patient provides a horizontal reference line on the radiograph. On the average, individual variation of pelvic tilt in serial films was 1 0 and pelvic rotation 3.5 0 confirming satisfactory reproducibility. The horizontal reference enables estimation of pre- and postoperative leg length inequality (LLI) and of the angle of the acetabular cup (AA). Reproducibility allows assessment of the exact position of the femoral component and quantitative evaluation of radiolucency and bone resorption around the prosthetic implant in the follow-up of THR. (orig.)

  7. Hybrid SPECT/CT for the assessment of a painful hip after uncemented total hip arthroplasty

    International Nuclear Information System (INIS)

    Dobrindt, Oliver; Amthauer, Holger; Krueger, Alexander; Ruf, Juri; Wissel, Heiko; Grosser, Oliver S; Seidensticker, Max; Lohmann, Christoph H

    2015-01-01

    The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses

  8. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  9. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  10. Renal function after elective total hip replacement

    DEFF Research Database (Denmark)

    Perregaard, Helene; Damholt, Mette B; Solgaard, Søren

    2016-01-01

    Background and purpose - Acute kidney injury (AKI) is associated with increased short-term and long-term mortality in intensive care populations and in several surgical specialties, but there are very few data concerning orthopedic populations. We have studied the incidence of AKI and the prevale......Background and purpose - Acute kidney injury (AKI) is associated with increased short-term and long-term mortality in intensive care populations and in several surgical specialties, but there are very few data concerning orthopedic populations. We have studied the incidence of AKI...... and the prevalence of chronic kidney disease (CKD) in an elective population of orthopedic patients undergoing primary total hip replacement, hypothesizing that chronic kidney disease predisposes to AKI. Patients and methods - This was a single-center, population-based, retrospective, registry-based cohort study...... involving all primary elective total hip replacements performed from January 2003 through December 2012. Patient demographics and creatinine values were registered. We evaluated the presence of CKD and AKI according to the international guidelines for kidney disease (KDIGO Acute Kidney Injury Workgroup 2013...

  11. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  12. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  13. [Total hip endoprosthesis following resection arthroplasty].

    Science.gov (United States)

    Engelbrecht, E; Siegel, A; Kappus, M

    1995-08-01

    From 1976 to December 1994, a total of 347 patients underwent implantation of a hip prosthesis at the ENDO-Klinik for treatment of an unsatisfactory condition following resection arthroplasty. From 1976 to 1987, 143 patients were treated and in 1989 the results obtained in these patients were analysed: 99 of them were available for a follow-up examination in 1989, and 64 for a further examination in 1995. In 130 cases infection had been the reason for joint resection. At the time of the prosthesis operation (1-20 years later) intraoperative biopsy revealed that infection was still present in 41 cases (31.5%). Only 15 of these infections had been detected preoperatively by joint aspiration. This shows that the value of resection arthroplasty as a method of treating periprosthetic infection is limited and lends support to the one-stage exchange operation, which is the method we prefer in cases of infected hip prostheses. The operative technique and preparation for implantation of the prosthesis are described, as are septic and aseptic complications and the measures that can be taken to treat them. In spite of the patients' generally poor initial condition and with due consideration for the further revision operations, the medium-term results finally obtained are poor in only 9%.

  14. The efficiency of risedronate in reducing bone resorption after total hip arthroplasty: a meta-analysis of randomized control trials at a minimum of 6 months' follow-up.

    Science.gov (United States)

    Yang, Liqing

    2018-04-17

    Recently risedronate is suggested to be effective for the prevention and treatment of for osteoporosis in total hip arthroplasty. This meta-analysis aimes to evaluate the efficacy of risedronate in reducing femoral periprosthetic bone mineral density loss in patients undergoing primary total hip arthroplasty. A systematic search was performed in Medline (1966-31 October 2017), PubMed (1966-31 October 2017), Embase (1980-31 October 2017), ScienceDirect (1985-31 October 2017) and the Cochrane Library. Only randomized controlled trial (RCT) were included. Fixed/random effect model was used according to the heterogeneity tested by I2 statistic. Meta-analysis was performed using Stata 11.0 software. The outcome measures included periprosthetic bone mineral density, length of stay and adverse effects. Four RCTs including 198 patients met the inclusion criteria. The present meta-analysis showed that there were significant differences between treatment groups in terms of periprosthetic bone mineral density in Gruen zones 1 (standard mean difference (SMD) = 0.758, 95% CI 0.469 to 1.047, P = 0.000), 2 (SMD = 0.814, 95% CI 0.523 to 1.106, P = 0.000), 3 (SMD = 0.340, 95% CI 0.059 to 0.622, P = 0.018), 6 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000), and 7 (SMD = 2.400, 95% CI 2.029 to 2.771, P = 0.000). Oral risedronate could significantly reduce periprosthetic bone resorption around an uncemented femoral stem (Gruen zones 1, 2, 3, 6, and 7) up to 6 months after THA. In addition, no severe adverse events were identified. Future trials of risedronate treatment after THA should focus on clinically relevant end points such as the risks of fracture and revision arthroplasty.

  15. Tribology of total hip arthroplasty prostheses

    Science.gov (United States)

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928

  16. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  17. Postoperative pain treatment after total hip arthroplasty

    DEFF Research Database (Denmark)

    Højer Karlsen, Anders Peder; Geisler, Anja; Petersen, Pernille Lykke

    2015-01-01

    Treatment of postoperative pain should rely on results from randomized controlled trials and meta-analyses of high scientific quality. The efficacy of a particular intervention may depend on the type of surgical procedure, which supports the reporting of "procedure-specific" interventions. The aim...... of this systematic review was to document the procedure-specific evidence for analgesic interventions after total hip arthroplasty (THA). This PRISMA-compliant and PROSPERO-registered review includes randomized placebo-controlled trials (RCTs) of medication-based analgesic interventions after THA. Endpoints were......, and lumbar plexus block reduced nausea and pruritus. The GRADE-rated quality of evidence ranged from low to very low throughout the analyses. This review demonstrated, that some analgesic interventions may have the capacity to reduce mean opioid requirements and/or mean pain intensity compared with controls...

  18. Total hip replacement for Mseleni Joint Disease undertaken in a ...

    African Journals Online (AJOL)

    found that hip surgery in this setting is of great benefit to Mseleni Joint Disease ... Conclusions: Hip surgery in this setting is of great benefit to the Mseleni Joint Disease patients but further attention .... The total hip score was divided into pain.

  19. Total hip arthroplasty at the rothman institute.

    Science.gov (United States)

    Austin, Matthew S; Higuera, Carlos A; Rothman, Richard H

    2012-07-01

    Total hip arthroplasty (THA) is one of the most successful surgical interventions devised in modern times. Attempts to change the current THA procedure with unproven innovations bring the risk of increased failure rates while trying to improve the benefit of the surgery. This manuscript examines the evolution of THA at the Rothman Institute illustrating the key elements that lead the success of this procedure at this institution. These key elements include femoral stem design, use of highly crossed-linked polyethylene and use of pain and rehabilitation protocols. We attempted to describe the long-term results regarding safety, effectiveness, and durability of specific THA implant designs used at this institution drawing on reported evidence in the literature. The authors performed a review of peer-reviewed articles related to the Rothman Institute's experience with THA. Total hip arthroplasty is an efficient, safe, and durable procedure. It is a highly successful operation to restore function and improve pain. The survivorship of THA procedures at the Rothman Institute is higher than 99% at 10 years based on mechanical failure. The use of collarless, tapered wedge femoral stem, highly crossed-linked polyethylene, and improved pain rehabilitation protocols have contributed to this success. There is a well-documented long-term survivorship after THA. Future innovation in THA should address new challenges with younger and more demanding patients, rather than change current methods that have a proven good survivorship. This innovation depends mainly upon improvements in the bearing surfaces and advances in pain control and rehabilitation.

  20. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    Science.gov (United States)

    2006-01-01

    Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a

  1. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kjærsgaard-Andersen, Per; Kehlet, Henrik

    2014-01-01

    STUDY DESIGN: Retrospective review of prospectively collected data. OBJECTIVE: To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors. METHODS: Prospective data on preoperative patient.......31-3.40)] but not hospital stay of hip...

  2. Process optimized minimally invasive total hip replacement

    Directory of Open Access Journals (Sweden)

    Philipp Gebel

    2012-02-01

    Full Text Available The purpose of this study was to analyse a new concept of using the the minimally invasive direct anterior approach (DAA in total hip replacement (THR in combination with the leg positioner (Rotex- Table and a modified retractor system (Condor. We evaluated retrospectively the first 100 primary THR operated with the new concept between 2009 and 2010, regarding operation data, radiological and clinical outcome (HOOS. All surgeries were perfomed in a standardized operation technique including navigation. The average age of the patients was 68 years (37 to 92 years, with a mean BMI of 26.5 (17 to 43. The mean time of surgery was 80 min. (55 to 130 min. The blood loss showed an average of 511.5 mL (200 to 1000 mL. No intra-operative complications occurred. The postoperative complication rate was 6%. The HOOS increased from 43 points pre-operatively to 90 (max 100 points 3 months after surgery. The radiological analysis showed an average cup inclination of 43° and a leg length discrepancy in a range of +/- 5 mm in 99%. The presented technique led to excellent clinic results, showed low complication rates and allowed correct implant positions although manpower was saved.

  3. Physical activity of elderly patients after total hip arthroplasty.

    Science.gov (United States)

    Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna

    2007-01-01

    Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.

  4. TOTAL HIP REPLACEMENT IN LEGG-CALVÉ-PERTHES DISEASE

    DEFF Research Database (Denmark)

    Froberg, Lonnie; Christensen, Finn; Pedersen, Niels Wisbech

    2009-01-01

    INTRODUCTION Poor long-time results in patients with Legg-Calvé-Perthes disease (LCP) are most often due to degenerative hip disease. The purpose of this study was to investigate if patients with LCP have an increased rate of total hip replacement (THR) compared to sex- and age-matched persons....... MATERIAL AND METHODS 167 LCP patients presented to our institution from 1941 to 1962. All patients were treated conservatively by a Thomas splint. Retrospectively medical records and radiographs were retrieved. Data from the Danish Hip Replacement Register and the Registries of the National Board of Health...... to follow-up and 3) patients with previous surgery to pelvis or lower limbs. 135 patients (156 hips) were enrolled in this study and 32 patients (35 hips) were excluded. RESULTS 20 hips out of 156 hips in patients with LCP have had a THR. Mean age at operation for the women was 50 years and 44 years...

  5. Metallic Modular Taper Junctions in Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Timothy McTighe

    2015-08-01

    Full Text Available The emergence of modularity in total hip arthroplasty (THA in the 1980s and 1990s was based on the fact that the benefit of these design features outweighed the risk. The use of metallic modular junctions presents a unique set of advantages and problems for use in THA. The advantages include improvement in fit and fill of the implant to bone, restoration of joint mechanics, reduced complications in revision surgery and reduction of costly inventory. However, the risks or concerns are a little harder to identify and deal with. Certainly corrosion, and fatigue failure are the two most prevalent concerns but now the specifics of fretting wear and corrosive wear increasing particulate debris and the potential biological response is having an impact on the design and potential longevity of the reconstructed hip. Material and designs are facing a shorter life expectancy than what was previously thought, mostly due to an increasing level of physical activity by the patient. Because there are no accurate laboratory test whereby the service life and performance of these implants can be predicted, early controlled clinical evaluations are necessary. Early publication of testing and clinical impressions should be encouraged in an attempt to reduce exposure to potential at risk patients, implants and material. The reduction and possible elimination of risks will require a balancing of all the variables requiring a multidisciplinary endeavor. This paper is designed to review the risk factors, and benefits of modular junctions in total hip arthroplasty (THA. Also some basic engineering principals that can reduce risk factors and improve functionality of modular junctions.

  6. Total hip replacements at Kikuyu Hospital, Kenya | Kingori | East ...

    African Journals Online (AJOL)

    Background: Total joint arthroplasty is a highly effective procedure that is frequently performed in elderly patients. This is not so in the third world and is not frequently performed. Total hip replacement (THR) relieves the pain and functional disability experienced by patients with moderate to severe arthritis of the hip, ...

  7. Late total hip arthroplasty dislocation due to yoga

    Directory of Open Access Journals (Sweden)

    Murillo Adrados, MD

    2018-06-01

    Full Text Available Yoga has become a popular form of exercise, recreation, and meditation for adults in the United States. As the popularity of both yoga and the incidence of hip replacements have both coincidentally increased over the last 2 decades, we imagine that the number of total hip replacement patients partaking in the practice of yoga has also increased. There are no clear guidelines available for yoga practice following hip replacement. To date, there have been no published reports of prosthetic hip dislocations during yoga. We present 2 cases of late total hip dislocations during yoga and provide a review of the available orthopaedic literature and our recommendations on patient restrictions and education with respect to practicing yoga after a hip replacement.

  8. Prevalence of Total Hip and Knee Replacement in the United States.

    Science.gov (United States)

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  9. Digital versus analogue preoperative planning of total hip arthroplasties - A randomized clinical trial of 210 total hip arthroplasties

    NARCIS (Netherlands)

    The, Bertram; Verdonschot, Nico; van Horn, Jim R.; van Ooijen, Peter M. A.; Diercks, Ron L.

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized

  10. Contralateral Total Hip Arthroplasty After Hindquarter Amputation

    Directory of Open Access Journals (Sweden)

    Scott M. M. Sommerville

    2006-01-01

    Full Text Available We describe the management and outcome of a 62-year old lady who developed severe osteoarthritis of the hip, nine years after a hindquarter amputation for radiation-induced sarcoma of the contralateral pelvis. The difficulties of stabilising the pelvis intraoperatively and the problems of postoperative rehabilitation are outlined. The operation successfully relieved her pain and restored limited mobility.

  11. Total hip replacement surgery in Ethiopia | Gokcen | East and ...

    African Journals Online (AJOL)

    Background: Total hip replacement (THR) surgery has evolved over years to the point that it has been considered as "the operation of the century". For developed countries, arthroplasty is well established for the management of various joint disorders and has completely revolutionised the treatment of the arthritic hip.

  12. Activity and Quality of Life after Total Hip Arthroplasty.

    Science.gov (United States)

    Świtoń, Anna; Wodka-Natkaniec, Ewa; Niedźwiedzki, Łukasz; Gaździk, Tadeusz; Niedźwiedzki, Tadeusz

    2017-10-31

    Coxarthrosis is a chronic musculoskeletal condition that causes severe pain and considerable limi-tation of the patient's motor performance. Total hip arthroplasty is one of the most common and effective methods used in the treatment of advanced degenerative changes. The aim of the present study was to evaluate the activity and quality of life of patients after unilateral total hip arthroplasty. The study was conducted in a group of 189 patients who had undergone unilateral total hip arthroplasty. Goniometry was used to determine the range of motion of both hip joints. Patients' physical ability and pain severity were assessed based on the Harris Hip Score (HHS) questionnaire. The examination of the range of motion in the lower extremities revealed statistically significant diffe-rences in flexion (p<0.01), abduction (p=<0.01), adduction (p<0.01) and external rotation (p<0.01) between the operated and the healthy extremity. The greatest limitation of motion was demonstrated for external rotation (<14°). Approximately 14% of the patients were not able to perform this motion in their healthy hip joint, while 17.5% of them could not do so in the affected hip joint. Analysis of HHS results (mean = 79 pts) revealed that more than 50% of the patients described their functional ability and quality of life as good and excellent. It was demonstrated that 54% of patients did not suffer from pain, whereas minor or mild pain was noted in 35%. 1. A subjective clinical assessment of patients after total hip arthroplasty showed that their quality of life had improved. 2. It is necessary to perform physiotherapy after total hip arthroplasty, on both the operated and healthy side. 3. Exacerbation of pain and impaired activity in patients after total hip arthroplasty were associated with the female sex to a considerable extent.

  13. The stability of the femoral component of a minimal invasive total hip replacement system.

    NARCIS (Netherlands)

    Willems, M.M.M.; Kooloos, J.G.M.; Gibbons, P.; Minderhoud, N.; Weernink, T.; Verdonschot, N.J.J.

    2006-01-01

    In this study, the initial stability of the femoral component of a minimal invasive total hip replacement was biomechanically evaluated during simulated normal walking and chair rising. A 20 mm diameter canal was created in the femoral necks of five fresh frozen human cadaver bones and the femoral

  14. Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    Vasileios Sakellariou

    2014-09-01

    Full Text Available Developmental dysplasia of the hip (DDH or congenital hip dysplasia (CDH is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DDH, 32.5 years for low dislocation, 31.2 years for high dislocation with a false acetabulum, and 46.4 years for high dislocation without a false acetabulum. Thorough understanding of the bony and soft tissue deformities induced by dysplasia is crucial for the success of total hip arthroplasty. It is important to evaluate the existing acetabular deformity three-dimensionally, and customize the correction in accordance with the quantity and location of ace tabular deficiencies. Acetabular reconstruction in patients with DDH is hallenging. Interpretation of published data is difficult and should be done with caution because most series include patients with different types of hip disease. In general, the complication rate associated with THA is higher in patients with hip dysplasia than it is in patients with osteoarthritis. Overall, clinical and functional outcomes following THA in patients hip dysplasia (DDH differ from those treated for primary hip osteoarthritis, possibly due to the lower age and level of activity. Although function scores decline with age, the scores for pain and range of motion presented with a statistically significant improvement in the long-term.

  15. Analgesia after total hip replacement: epidural versus psoas ...

    African Journals Online (AJOL)

    tive analgesia following total hip replacement surgery. The research design was a ... matoma, intra-abdominal injury and pain due to spasm of the lumbar paravertebral ..... 2. Brown DL. Spinal, epidural, and caudal anesthesia In: Miller RD, ed.

  16. Unipedal standing exercise and hip bone mineral density in postmenopausal women: a randomized controlled trial.

    Science.gov (United States)

    Sakai, Akinori; Oshige, Toshihisa; Zenke, Yukichi; Yamanaka, Yoshiaki; Nagaishi, Hitoshi; Nakamura, Toshitaka

    2010-01-01

    The aim of this study was to test the effect of unipedal standing exercise on bone mineral density (BMD) of the hip in postmenopausal women. Japanese postmenopausal women (n = 94) were assigned at random to an exercise or control group (no exercise). The 6-month exercise program consisted of standing on a single foot for 1 min per leg 3 times per day. BMD of the hip was measured by dual-energy X-ray absorptiometry. There was no significant difference in age and baseline hip BMD between the exercise group (n = 49) and control group (n = 45). Exercise did not improve hip BMD compared with the control group. Stepwise regression analysis identified old age as a significant determinant (p = 0.034) of increased hip total BMD at 6 months after exercise. In 31 participants aged >/=70 years, the exercise group (n = 20) showed significant increase in the values of hip BMD at the areas of total (p = 0.008), intertrochanteric (p = 0.023), and Ward's triangle (p = 0.032). The same parameters were decreased in the control group (n = 11). The percent changes in hip BMD of the exercise group were not significantly different from those of the control group either in the participants with low baseline hip total BMD ( or =80% of the young adult mean). In conclusion, unipedal standing exercise for 6 months did not improve hip BMD in Japanese postmenopausal women. Effect of exercise on hip total BMD was age dependent. In participants aged > or =70 years, the exercise significantly increased hip total BMD.

  17. Nurses' responsibilities in postoperative pain management following total hip arthroplasty

    OpenAIRE

    Dumolard, Pierre; Gök, Mustafa; Le, Ngoc

    2017-01-01

    Total hip arthroplasty is the replacement of a hip joint that has been severely damaged. The operation is recommended if other treatments have not responded adequately. As the nurses are the professionals who spend the most time with patients after the surgery, they play an important role in the patient’s pain management. The aim of the thesis is to define the nurse’s responsibilities in the care of total hip arthroplasty. The purpose of the thesis is to analyze existing research, which may s...

  18. Radiological examinations of complications after total hip replacement Pt. 1

    International Nuclear Information System (INIS)

    Luzsa, Gyoergy; Reti, Peter; Lakatos, Jozsef

    1985-01-01

    The radiological findings of complications after total hip replacement are summarized by analizing the data of control examinations of the operated patients at the National Institute for Rheumatology and Physiotherapy. In this first part the types of total hip replacements and the radiological methods (native x-ray, fistulography, arthrography, needle biopsy and scintigraphy using sup(99m)Tc isotope) are surveyed, and the radiological findings of the septic surgical complications are described. (author)

  19. Managing infection in the revision total hip replacement patient.

    Science.gov (United States)

    Halley, D K

    1993-01-01

    Deep infection is one of the most devastating complications in total hip replacement. This dreaded complication is presented in considerable detail with special emphasis on prevention, diagnosis, and various methods of surgical and antibiotic treatment. Basic fundamentals of antibiotic therapy are reviewed. In addition, guidelines are given for the indications of surgical intervention, the type and staging of operative procedures, with detailed techniques of the various operative procedures used to treat the infected total hip implant patient.

  20. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty. Precision biased by region of interest and rotation of the hip

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Varmarken, Jens-Erik; Ovesen, Ole

    2009-01-01

      Introduction:  Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type of ROI...... the hip was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without...

  1. BIOMECHANICAL JUSTIFICATION OF THE THREADED ELEMENT’S FORM OF THE TOTAL HIP ENDOPROSTHESIS’ ACETABULAR COMPONENT

    Directory of Open Access Journals (Sweden)

    PANCHENKO S. P.

    2017-03-01

    Full Text Available Abstract. Formulation of the problem. Total hip replacement (THR remains to be responsible for the markable clinical achievements of contemporal orthopaedic surgery [1; 2; 4]. It should be noted, that numerous efforts to create an “ideal” uncemented hip endoprosthesis’ construction were failed, but led into wide diversity of implants. Such a diversity allowes to individualize implant type selection and to improve implant’s survival and total THR’s clinical outcomes [1; 4]. Outcomes mentioned above determine successful application of total hip replacement as a treatment method. Consequently, development of new and improvement of existing hip endoprosthesis’ constructions seems to be of current interest for contemporal orthopaedic surgery. Purpose. To determine optimal parametres of threaded element’s geometry of total hip endoprosthesis’ threaded acetabular component. Conclusion. There were revealed that threaded element model with right-angled triangle transverse section shape seems to be the most effective considering hardness, while the triangle is leaned on the bone massive with its cathetus. At the same time, results of calculations represent pelvic bone stress-strain state during THR quantitavely and stipulate further research.

  2. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie

    2012-01-01

    Background The results of primary total hip arthroplasties (THAs) after pediatric hip diseases such as developmental dysplasia of the hip (DDH), slipped capital femoral epiphysis (SCFE), or Perthes' disease have been reported to be inferior to the results after primary osteoarthritis of the hip (OA.......9%) were operated due to pediatric hip diseases (3.1% for Denmark, 8.8% for Norway, and 1.9% for Sweden) and 288,435 THAs (77.8%) were operated due to OA. Unadjusted 10-year Kaplan-Meier survival of THAs after pediatric hip diseases (94.7% survival) was inferior to that after OA (96.6% survival......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...

  3. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Lee, Y K; Ha, Y C; Yoo, J-I; Jo, W L; Kim, K-C; Koo, K H

    2017-06-01

    We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival. Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  4. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    Science.gov (United States)

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (Pcup coverage (Pearson r=0.761, Pcup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  5. Comparison of femoral neck fracture healing and affected limb pain after anterolateral-approach minimally invasive total hip replacement and hemiarthroplasty

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Cao

    2017-04-01

    Full Text Available Objective: To study the differences in femoral neck fracture healing and affected limb pain after anterolateral-approach minimally invasive total hip replacement and hemiarthroplasty. Methods: A total of 92 patients with femoral neck fracture who received hip replacement in our hospital between May 2013 and December 2015 were selected and randomly divided into total hip and half hip group, total hip group received anterolateral-approach minimally invasive total hip replacement, half hip group received anterolateral-approach minimally invasive hemiarthroplasty, and 1 month after operation, serum was collected to detect the levels of bone metabolism markers, osteocyte cytokines, SP and CGRP. Results: 1 month after operation, serum PINP, PICP, BMP, TGF-β, FGF, IGF-I and IGF-II levels of total hip group were significantly higher than those of half hip group while TRAP5b and CatK levels were significantly lower than those of half hip group; the day after operation, serum pain media SP and CGRP levels were not significantly different between the two groups of patients; 36 h after operation, serum SP and CGRP levels of total hip group were significantly lower than those of half hip group. Conclusion: The bone metabolism after anterolateral-approach minimally invasive total hip replacement is better than that after hemiarthroplasty, and the degree of pain is less than that after hemiarthroplasty.

  6. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

    Science.gov (United States)

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-02-01

    Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41-78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ -1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2-10) years. Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were "at risk" (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the 10 cases were "at risk" in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3-48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually.

  7. MULTIMODAL ANALGESIA AFTER TOTAL HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    I. G. Mukutsa

    2012-01-01

    Full Text Available Purpose - to assess the effect of multimodal analgesia in the early rehabilitation of patients after hip replacement. Materials and methods. A prospective single-centre randomized research, which included 32 patients. Patients of the 1st group received paracetamol, ketorolac and tramadol, the 2nd group of patients - ketorolac intravenously and the 3rd group of patients - etoricoxib and gabapentin. Patients of the 2nd and the 3rd groups underwent epidural analgesia with ropivacaine. Multimodal analgesia was carried out for 48 hours after the surgery. Assessment of pain intensity was performed by the VAS (visual analogue scale, a neuropathic pain component - on the DN4 questionnaire . Time was recorded during the first and second verticalization of patients, using the distance walkers and by fixing the distance covered with in 2 minutes. Results. The intensity of pain for more than 50 mm on VAS at movement at least once every 48 hours after the surgery was occurred among 9% of the 1st group, 22% of patients from the 2nd group and 8% of patients of the 3rd group. Number of patients with neuropathic pain component decreased from 25% to 3% (p ≤ 0.05. The first verticalization was performed 10 ± 8 hours after the surgery, the second - 21 ± 8 hours later. Two-minute walk distance was 5 ± 3 and 8 ± 4 m, respectively. It is noted more frequent adverse events in patients of the 1st group was noted compared to patients of the 2nd and the 3rd groups during first (91%, 33% and 25%, p ≤ 0.05 and the second verticalization (70%, 25% and 17%, p ≤ 0.05. Multimodal analgesia allows to proceed with the successful activation of patients after hip replacement with in the first day after the surgery. The 3rd group patients are noted with a tendency for the optimal combination of efficient and safe of analgetic therapy.

  8. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement

    OpenAIRE

    ?yp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; W?ostowska, Ewa; Stanis?awska, Iwona; Szypu?a, Jan; Tomaszewski, Wies?aw

    2016-01-01

    Background Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. Material/Methods A total of 192 patients (the mean age 61.03?10.89) suffering from hip osteoarthritis (OA) were evaluated before an...

  9. Hip malformation is a very common finding in young patients scheduled for total hip arthroplasty

    DEFF Research Database (Denmark)

    Karimi, Dennis; Kallemose, Thomas; Troelsen, Anders

    2018-01-01

    and prevalences of hip malformations were; CAM-deformity 50.9 and 25.5%, coxa profunda 33 and 27.4%, acetabular retroversion 33 and 29.2%, and acetabular dysplasia 10.4 and 3.8%. All patients showed minimum of one malformation. Prevalences of Tönnis grade 0-1 were 22.6% and 2-3 were 77.4%. CONCLUSION: All......INTRODUCTION: In Denmark, 20% of all registered total hip arthroplasties (THA) from 1995 to 2014 has been patients younger than 60 years with primary idiopathic osteoarthritis (OA). It is speculated that hip malformations may be a major contributor to early OA development. It has been shown...... that hip malformation may compromise implant position and, therefore, identifying and knowing the incidence of malformations is important. Our aim was to assess the prevalence and type of hip malformations in a cohort of younger patients undergoing THA. MATERIALS AND METHODS: In this prospective two center...

  10. Effect of HIP/ribosomal protein L29 deficiency on mineral properties of murine bones and teeth.

    Science.gov (United States)

    Sloofman, Laura G; Verdelis, Kostas; Spevak, Lyudmila; Zayzafoon, Majd; Yamauchi, Mistuo; Opdenaker, Lynn M; Farach-Carson, Mary C; Boskey, Adele L; Kirn-Safran, Catherine B

    2010-07-01

    Mice lacking HIP/RPL29, a component of the ribosomal machinery, display increased bone fragility. To understand the effect of sub-efficient protein synthetic rates on mineralized tissue quality, we performed dynamic and static histomorphometry and examined the mineral properties of both bones and teeth in HIP/RPL29 knock-out mice using Fourier transform infrared imaging (FTIRI). While loss of HIP/RPL29 consistently reduced total bone size, decreased mineral apposition rates were not significant, indicating that short stature is not primarily due to impaired osteoblast function. Interestingly, our microspectroscopic studies showed that a significant decrease in collagen crosslinking during maturation of HIP/RPL29-null bone precedes an overall enhancement in the relative extent of mineralization of both trabecular and cortical adult bones. This report provides strong genetic evidence that ribosomal insufficiency induces subtle organic matrix deficiencies which elevates calcification. Consistent with the HIP/RPL29-null bone phenotype, HIP/RPL29-deficient teeth also showed reduced geometric properties accompanied with relative increased mineral densities of both dentin and enamel. Increased mineralization associated with enhanced tissue fragility related to imperfection in organic phase microstructure evokes defects seen in matrix protein-related bone and tooth diseases. Thus, HIP/RPL29 mice constitute a new genetic model for studying the contribution of global protein synthesis in the establishment of organic and inorganic phases in mineral tissues. 2010 Elsevier Inc. All rights reserved.

  11. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty

    OpenAIRE

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-01-01

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of th...

  12. Primary cemented total hip arthroplasty: 10 years follow-up

    Directory of Open Access Journals (Sweden)

    Nath Rajendra

    2010-01-01

    Full Text Available Background: Primary cemented total hip arthroplasty is a procedure for non-traumatic and traumatic affections of the hip. Long term follow-up is required to assess the longevity of the implant and establish the procedure. Indo-Asian literature on long term result of total hip arthroplasty is sparse. We present a 10-year follow-up of our patients of primary cemented total hip arthroplasty. Materials and Methods: We operated 31 hips in 30 patients with primary cemented total hip arthroplasty. We followed the cases for a minimum period of 10 years with a mean follow-up period of 12.7 years. The mean age of the patients was 60.7 years (range 37-82 yrs male to female ratio was 2:1. The clinical diagnoses included - avascular necrosis of femoral head (n=15, sero positive rheumatoid arthritis (n=5, seronegative spondylo-arthropathy (n=4, neglected femoral neck fractures (n=3, healed tubercular arthritis (n=2 and post traumatic osteoarthritis of hip (n=2. The prostheses used were cemented Charnley′s total hip (n=12 and cemented modular prosthesis (n=19. The results were assessed according to Harris hip score and radiographs taken at yearly intervals. Results: The mean follow-up is 12.7 yrs (range 11-16 yrs Results in all operated patients showed marked improvement in Harris hip score from preoperative mean 29.2 to 79.9 at 10 years or more followup. However, the non-inflammatory group showed more sustained long term improvement as compared to the inflammatory group, as revealed by the Harris hip score. Mean blood loss was 450ml (±3.7 ml, mean transfusion rate was 1.2 units (±.3. The complications were hypotension (n=7, shortening> 1.5 cm (n=9, superficial infection (n=2 and malposition of prosthesis (n=1. Conclusion: The needs of Indian Asian patients, vary from what is discussed in literature. The pain tolerance is greater than western population and financial constraints are high. Thus revision surgery among Indian-Asian patients is less compared

  13. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    Directory of Open Access Journals (Sweden)

    Masanori Fujii

    2017-01-01

    Full Text Available Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months. The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE angle and the bone coverage index (BCI from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3% and the minimum cup-CE angle was −9.2° (BCI: 48.8%. Thin radiolucent lines were observed in 5 hips (2.3%, which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50% was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%.

  14. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement.

    Science.gov (United States)

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-07-25

    BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (pwater exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR.

  15. The history of biomechanics in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Jan Van Houcke

    2017-01-01

    Full Text Available Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro, in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA. The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  16. Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty

    NARCIS (Netherlands)

    Weel, Hanneke; Lindeboom, Robert; Kuipers, Sander E.; Vervest, Ton M. J. S.

    2017-01-01

    Harris Hip Score (HHS) is a surgeon administered measurement for assessing hip function before and after total hip arthroplasties (THA). Patient reported outcome measurements (PROMs) such as the Oxford Hip Score (OHS) are increasingly used. HHS was compaired to the OHS assessing whether the HHS can

  17. Particulate metallic debris in cemented total hip arthroplasty.

    Science.gov (United States)

    Salvati, E A; Betts, F; Doty, S B

    1993-08-01

    Several studies conducted by the authors in the last six years demonstrate that the generation of metallic debris is more severe with titanium alloy than with cobalt-chrome alloy femoral components in cemented total hip arthroplasty (THA). The debris is generated from the articulating surface, particularly if entrapped acrylic debris produces three-body wear, and from the stem surface when the component loosens and abrades against fragmented cement. In selected cases in which the titanium metallic debris is copious, premature failure and severe progressive bone loss occurs. Electron microscopy demonstrates that the particles of metallic debris can be extremely small (a few hundredths of 1 micron). They are phagocytized by the macrophages and transported to the phagolysosomes. In this highly corrosive environment, the very high surface area of the particles may release toxic concentrations of the constituents of the alloy intracellularly, probably leading to progressive cell degeneration and death, with subsequent release of intracellular enzymes and ingested metallic debris. This cycle most likely repeats itself, leading to tissue necrosis. The results presented do not support the use of titanium alloy femoral components for cemented THA, particularly for the articulating surface.

  18. Hip Hip Hurrah! Hip size inversely related to heart disease and total mortality

    DEFF Research Database (Denmark)

    Heitmann, B L; Lissner, L

    2011-01-01

    During the past decade a series of published reports have examined the value of studying the relation between hip circumferences and cardiovascular end points. Specifically, in a series of recent studies the independent effects of hip circumference have been studied after adjustment for general o...... for women than men, but is evident in both genders. In this 'viewpoint', we wish to draw attention to the emerging body of evidence and to encourage researchers to continue collecting measures of lower body size in their surveys....... obesity and/or waist circumference. These studies have been remarkable in terms of their consistency, and in the unexpected finding of an adverse effect of small hip size, after statistically correcting for differences in general and abdominal size. The hazard related to a small hip size may be stronger...

  19. Predictors of excellent early outcome after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Smith George H

    2012-03-01

    Full Text Available Abstract Background Not all patients gain the same degree of improvement from total hip replacement and the reasons for this are not clear. Many investigators have assessed predictors of general outcome after hip surgery. This study is unique in its quest for the predictors of the best possible early outcome. Methods We prospectively collected data on 1318 total hip replacements. Prior to surgery patient characteristics, demographics and co-morbidities were documented. Hip function and general health was assessed using the Harris Hip score (HHS and the Short-Form 36 respectively. The HHS was repeated at three years. We took a maximal HHS of 100 to represent an excellent outcome (102 patients. Multiple logistic regression analysis was used to identify independent predictors of excellent outcome. Results The two strongest predictive factors in achieving an excellent result were young age and a high pre-operative HHS (p = 0.001. Conclusions It was the young and those less disabled from their arthritis that excelled at three years. When making a decision about the timing of hip arthroplasty surgery it is important to take into account the age and pre-operative function of the patient. Whether these patients continue to excel however will be the basis of future research.

  20. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Directory of Open Access Journals (Sweden)

    Haviv Barak

    2010-07-01

    Full Text Available Abstract Objective To assess the incidence of total hip arthroplasty (THA in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years. The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16% of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.

  1. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Science.gov (United States)

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  2. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs.

    Science.gov (United States)

    Levadnyi, Ievgen; Awrejcewicz, Jan; Gubaua, José Eduardo; Pereira, Jucélio Tomás

    2017-12-01

    The change in mechanical properties of femoral cortical bone tissue surrounding the stem of the hip endoprosthesis is one of the causes of implant instability. We present an analysis used to determine the best conditions for long-term functioning of the bone-implant system, which will lead to improvement of treatment results. In the present paper, a finite element method coupled with a bone remodelling model is used to evaluate how different three-dimensional prosthesis models influence distribution of the density of bone tissue. The remodelling process begins after the density field is obtained from a computed tomography scan. Then, an isotropic Stanford model is employed to solve the bone remodelling process and verify bone tissue adaptation in relation to different prosthesis models. The study results show that the long-stem models tend not to transmit loads to proximal regions of bone, which causes the stress-shielding effect. Short stems or application in the calcar region provide a favourable environment for transfer of loads to the proximal region, which allows for maintenance of bone density and, in some cases, for a positive variation, which causes absence of the aseptic loosening of an implant. In the case of hip resurfacing, bone mineral density changes slightly and is closest to an intact femur. Installation of an implant modifies density distribution and stress field in the bone. Thus, bone tissue is stimulated in a different way than before total hip replacement, which evidences Wolff's law, according to which bone tissue adapts itself to the loads imposed on it. The results suggest that potential stress shielding in the proximal femur and cortical hypertrophy in the distal femur may, in part, be reduced through the use of shorter stems, instead of long ones, provided stem fixation is adequate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Failure rate of cemented and uncemented total hip replacements

    DEFF Research Database (Denmark)

    Makela, K. T.; Matilainen, M.; Pulkkinen, P.

    2014-01-01

    ). Participants 347 899 total hip replacements performed during 1995-2011. Main outcome measures Probability of implant survival (Kaplan-Meier analysis) along with implant survival with revision for any reason as endpoint (Cox multiple regression) adjusted for age, sex, and diagnosis in age groups 55-64, 65......Objective To assess the failure rate of cemented, uncemented, hybrid, and reverse hybrid total hip replacements in patients aged 55 years or older. Design Register study. Setting Nordic Arthroplasty Register Association database (combined data from Sweden, Norway, Denmark, and Finland......-74, and 75 years or older. Results The proportion of total hip replacements using uncemented implants increased rapidly towards the end of the study period. The 10 year survival of cemented implants in patients aged 65 to 74 and 75 or older (93.8%, 95% confidence interval 93.6% to 94.0% and 95.9%, 95...

  4. Ethamsylate and blood loss in total hip replacement.

    Science.gov (United States)

    Keith, I

    1979-01-01

    Nineteen consecutive patients undergoing total hip replacement under epidural anaesthesia were randomly divided into two groups. The treatment group received 1000 mg of ethamsylate intravenously before induction of anaesthesia. Blood lost during surgery was measured by a colorimetric technique. Closed suction drains were used and all blood lost after operation collected for measurement. Ethamsylate did not decrease the average volumes of blood lost during or after the operation. Neither did it reduce the requirements for blood transfusion. Although there were no side-effects attributable to ethamyslate, there seems to be no indication for its use in total hip replacement under epidural anaesthesia.

  5. Sequential radionuclide bone imaging in avascular pediatric hip conditions

    International Nuclear Information System (INIS)

    Minikel, J.; Sty, J.; Simons, G.

    1983-01-01

    Radionuclide bone imaging was performed on six patients with various hip conditions. Initial bone images revealed diminished uptake of isotope /sup 99m/Tc-MDP in the capital femoral epiphysis. Following therapeutic intervention, repeat bone scans revealed normal uptake of /sup 99m/Tc-MDP in the capital femoral epiphysis. Subsequent radiographs revealed that avascular necrosis had not occurred. There are two types of avascularity: the potentially reversible, and the irreversible. Attempts should be made toward early recognition of the potentially reversible avascular insult. With early recognition, surgical reconstruction prior to osteophyte death may result in revascularization. If this can be accomplished, avascular necrosis can be avoided

  6. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel

    2015-01-01

    INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk and heritab......INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk...... and heritability of primary osteoarthritis of the hip leading to a total hip arthroplasty, and if this heritability increased with increasing age. METHODS: In a nationwide population-based follow-up study 118,788 twins from the Danish Twin Register and 90,007 individuals from the Danish Hip Arthroplasty Register...... not have had a total hip arthroplasty at the time of follow-up. RESULTS: There were 94,063 twins eligible for analyses, comprising 835 cases of 36 concordant and 763 discordant twin pairs. The probability increased particularly from 50 years of age. After sex and age adjustment a significant additive...

  7. Total hip and knee joint replacement: perioperative clinical aspects

    Directory of Open Access Journals (Sweden)

    Luciana Pereira Almeida de Piano

    2010-09-01

    Full Text Available Objective: To understand the profile of patients undergoing hip and knee replacement during two years, and to compare the data obtained with the literature. Methods: A total of 323 medical records were reviewed to analyze the perioperative data of patients submitted to hip and knee replacement. Results: Osteoarthritis was the main indication for both procedures and male patients were heavier than females (p < 0.05. Hypertension was the prevalent disease among patients. Blood loss was more frequent in knee surgery than in the hip. Conclusions: The profile of patients undergoing total arthroplasty improved substantially over the past decade due to shorter hospital stay, lower risk of thromboembolic events and no infection as compared to previous reports.

  8. Development and Validation of Perioperative Risk-Adjustment Models for Hip Fracture Repair, Total Hip Arthroplasty, and Total Knee Arthroplasty.

    Science.gov (United States)

    Schilling, Peter L; Bozic, Kevin J

    2016-01-06

    Comparing outcomes across providers requires risk-adjustment models that account for differences in case mix. The burden of data collection from the clinical record can make risk-adjusted outcomes difficult to measure. The purpose of this study was to develop risk-adjustment models for hip fracture repair (HFR), total hip arthroplasty (THA), and total knee arthroplasty (TKA) that weigh adequacy of risk adjustment against data-collection burden. We used data from the American College of Surgeons National Surgical Quality Improvement Program to create derivation cohorts for HFR (n = 7000), THA (n = 17,336), and TKA (n = 28,661). We developed logistic regression models for each procedure using age, sex, American Society of Anesthesiologists (ASA) physical status classification, comorbidities, laboratory values, and vital signs-based comorbidities as covariates, and validated the models with use of data from 2012. The derivation models' C-statistics for mortality were 80%, 81%, 75%, and 92% and for adverse events were 68%, 68%, 60%, and 70% for HFR, THA, TKA, and combined procedure cohorts. Age, sex, and ASA classification accounted for a large share of the explained variation in mortality (50%, 58%, 70%, and 67%) and adverse events (43%, 45%, 46%, and 68%). For THA and TKA, these three variables were nearly as predictive as models utilizing all covariates. HFR model discrimination improved with the addition of comorbidities and laboratory values; among the important covariates were functional status, low albumin, high creatinine, disseminated cancer, dyspnea, and body mass index. Model performance was similar in validation cohorts. Risk-adjustment models using data from health records demonstrated good discrimination and calibration for HFR, THA, and TKA. It is possible to provide adequate risk adjustment using only the most predictive variables commonly available within the clinical record. This finding helps to inform the trade-off between model performance and data

  9. Cemented total hip replacement cable debris and acetabular construct durability.

    Science.gov (United States)

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  10. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Science.gov (United States)

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  11. Influence of bone mineral density and hip geometry on the different types of hip fracture.

    Science.gov (United States)

    Li, Yizhong; Lin, Jinkuang; Cai, Siqing; Yan, Lisheng; Pan, Yuancheng; Yao, Xuedong; Zhuang, Huafeng; Wang, Peiwen; Zeng, Yanjun

    2016-01-01

    The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD) were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  12. Influence of bone mineral density and hip geometry on the different types of hip fracture

    Directory of Open Access Journals (Sweden)

    Yizhong Li

    2016-01-01

    Full Text Available The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  13. Support for total hip replacement surgery: Structures modeling, Gait Data Analysis and Report system

    Directory of Open Access Journals (Sweden)

    Gianluca Mario Izzo

    2012-03-01

    Full Text Available For the treatment of advanced damages of hip joints, Total Hip Arthroplasty is well proven. Due to the different mechanical properties of the prosthesis material and the bone tissue, a partial unloading of the periprosthetic bone occurs. The bone cement causes reduction in bone density as a result of removal of normal stress from the bone, leading to weakening of the bone in that area and the fracture risk increases. Bone loss is identified as one of the main reasons for loosening of the stem. Otherwise, thanks to the press-fit of the non-cemented stem achieved by surgery, the bone layers immediately adjacent to the stem are preloaded, thus encouraged growing, and the bone getting stronger. The non-cemented stem would be the better choice for every patient, but the question remains if the femur can handle the press- fitting surgery. This studies aim to develop a monitoring techniques based on Gait analysis and bone density changes to assess patient recovery after Total Hip Arthroplasty. Furthermore, to validate computational processes based on 3D modeling and Finite Element Methods for optimizing decision making in the operation process and selecting the suited surgical procedure. A vision could be minimizing risk of periprosthetic fracture during and after surgery. Patients: The sample presents 11 patients receiving cemented implant and 13 for the uncemented. Patients are grouped by type of implant. Three checkpoints were considered: before, after operation and one year later. CT scans, gaitrite and kinepro measurements have been realized. Main outcome measures: Fracture risk probability is higher in bone with low bone mineral density; therefore bones are more fragile in elderly people. BMD is indeed one parameter considered among all the observations. Periprosthetic fracture of the femur is a rare but complex complication of THA, and requires demanding surgery. As such, they result in considerable morbidity and dysfunction. Thus, tests of

  14. Postoperative radiation therapy after hip replacement in high-risk patients for development of heterotopic bone formation

    International Nuclear Information System (INIS)

    Hashem, R.; Rene, N.; Souhami, L.; Tanzer, M.; Evans, M.

    2011-01-01

    Purpose. - To report the results of postoperative radiation therapy in preventing the development of heterotopic bone formation after hip replacement surgery in high-risk patients. Patients and methods. - Between 1991 and 2007, 44 patients were preventively treated with postoperative RT after total hip replacement. In total, 47 hips were treated. All patients were considered at high risk for developing heterotopic bone formation. Most patients (63.5%) were treated because of a history of severe osteoarthritis or ankylosing spondylitis. All patients were treated with shaped parallel-opposed fields with a single fraction of 7 Gy using 6 or 18 MV photons. Most patients (94%) received radiation therapy within 72 hours postoperative and in only three patients radiation therapy was delivered after 72 hours post-surgery (5-8 days). Results. - Minimum follow-up was 1 year. There were 18 females and 26 males. Median age was 63 years (range: 18-80). Treatments were well tolerated and no acute toxicity was seen post-radiation therapy. Only one of the 47 hips (2%) developed heterotopic bone formation. This patient received postoperative radiation therapy to both hips but only developed heterotopic bone formation in one of them. None of the three patients treated beyond 72 hours failed. To date no late toxicity has been observed. Conclusion. - The use of postoperative radiation therapy was an effective and safe treatment in the prevention of heterotopic bone formation in a high-risk group of patients undergoing total hip replacement. (authors)

  15. Chronic pain following total hip arthroplasty: a nationwide questionnaire study

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Brandsborg, Birgitte; Lucht, Ulf

    2006-01-01

    BACKGROUND: Chronic post-operative pain is a well-recognized problem after various types of surgery, but little is known about chronic pain after orthopedic surgery. Severe pre-operative pain is the primary indication for total hip arthroplasty (THA). Therefore, we examined the prevalence...... was 93.6%. Two hundred and ninety-four patients (28.1%) had chronic ipsilateral hip pain at the time of completion of the questionnaire, and pain limited daily activities to a moderate, severe or very severe degree in 12.1%. The chronic pain state was related to the recalled intensity of early post...

  16. Alumina-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.

    Science.gov (United States)

    Jung, Yup Lee; Kim, Shin-Yoon

    2010-02-11

    The long-term durability of polyethylene lining total hip arthroplasty (THA) mainly depends on periprosthetic osteolysis due to wear particles, especially in young active patients. In hip simulator study, reports revealed significant wear reduction of the alumina ceramic-on-polyethylene articulation of THA compared with metal-on-polyethylene bearing surfaces. However, medium to long-term clinical studies of THA using the alumina ceramic-on-polyethylene are few and the reported wear rate of this articulation is variable. We reviewed the advantages and disadvantages of ceramicon- polyethylene articulation in THA, hip simulator study and retrieval study for polyethylene wear, in vivo clinical results of THA using alumina ceramic-on-polyethylene bearing surfaces in the literature, and new trial alumina ceramic-onhighly cross linked polyethylene bearing surfaces.

  17. Risk factors for renal dysfunction after total hip joint replacement

    DEFF Research Database (Denmark)

    Hassan, Basim Kamil; Sahlström, Arne; Dessau, Ram Benny Christian

    2015-01-01

    BACKGROUND AND PURPOSE OF THE STUDY: Renal injury and dysfunction are serious complications after major surgery, which may lead to increased morbidity and mortality. The objective of our study was to identify the possible risk factors for renal dysfunction after total hip joint replacement surger...... creatinine. Smoking, diabetes mellitus, high BMI, gender, and duration of surgery were not identified as significant risk factors........ METHODS: A retrospective study was conducted among 599 consecutive primary hip joint replacements performed between January 2011 and December 2013. According to the RIFLE criteria, increased postoperative serum creatinine was considered indicative of postoperative renal injury. The Welch two-sample test......, hypertension, general anesthesia, high ASA scores, low intra-operative systolic BP, and prophylactic dicloxacillin as significant risk factors. Low baseline systolic BP, low baseline diastolic blood pressure, and hip fracture diagnosis were independent risk factors for postoperative increase in serum...

  18. Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.

    Science.gov (United States)

    Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A

    2015-05-24

    Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.

  19. [Bone surgery for unstable hips in patients with cerebral palsy].

    Science.gov (United States)

    Poul, J; Pesl, M; Pokorná, M

    2004-01-01

    The aim of this retrospective study was to compare the efficacy of femoral osteotomy alone with that of osteotomy combined with an acetabular procedure in patients with unstable hips due to spastic cerebral palsy. Sixty-one hip joints in 50 patients who had shown distinct subluxation or dislocation of the joint were operated on. Eleven patients underwent bilateral surgery. Before bone surgery, soft-tissue release involving both the flexors and adductors was performed on 19 hips. Femoral osteotomy alone was performed on 29 hip joints and combined femoral and pelvic osteotomy was carried out on 32 joints.Twelve resections of the proximal femur in seven patients were evaluated as a separate group. All treated hip joints were assessed by clinical and radiographic examination at a follow-up of more than 5 years. The skiagraphs taken in a strictly neutral position of the lower limbs before surgery and at the final examination were evaluated on the basis of Reimers's migration index and Wiberg's centre-edge angle. The locomotor abilities of each child were categorized according to the Vojta scoring system for locomotor development. The range of motion in the treated hip joint was assessed using the standard S. F. T. R. method. The results obtained were statistically analyzed by the Kruskal- Wallis, one-way ANOVA test. A comparison of the results of femoral osteotomy alone with those of combined femoral and pelvic osteotomy showed that the post-operative values of the migration index and centre-edge angle, as compared with the pre-operative ones, were statistically higher (pVojta rating system. There was no change in the range of motion in the treated hip joints after the operation. In 28, out of the 32 joints treated by combined femoral and pelvic osteotomy, Salter osteotomy was performed and it showed a high efficacy in providing hip joint stability. The main emphasis during surgery was placed on the maximum acetabular rotation laterally. Femoral osteotomy alone was less

  20. Bone and soft tissue tumors of hip and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Bloem, Johan L., E-mail: j.l.bloem@lumc.nl [Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden (Netherlands); Reidsma, Inge I., E-mail: i.i.reidsma@lumc.nl [Leiden University Medical Center, Department of Radiology, PO Box 9600, 2300 RC Leiden (Netherlands)

    2012-12-15

    Objective is to identify epidemiologic and radiologic criteria allowing specific diagnoses of tumors and tumor-like lesions in the hip region and pelvis, and to optimize pre-operative staging. Patients with pelvic tumors are usually older, and their tumors are larger relative to patients with tumors in extremities. The majority of tumors in the pelvis are malignant (metastases, myeloma, chondrosarcoma, Ewing-, osteo-, and MFH/fibrosarcoma), while those in the proximal femur are in majority benign (fibrous dysplasia, solitary bone cyst, and osteoid osteoma). Soft tissue masses in the thigh in the elderly are typically sarcomas without tumor specific signs. Common tumor-like lesions occurring in the hip and pelvis that can mimic neoplasm are: infections (including tuberculosis), insufficiency/avulsion fractures, cysts, fibrous dysplasia, aneurysmal bone cyst, Langerhans cell histiocytosis, and Paget's disease. Local MR staging is based on the compartmental anatomy. The psoas and gluteal muscles are easily invaded by sarcoma originating in the ileum. The pectineus muscle protects the neurovascular bundle at the level of the hip. The thigh is separated into three compartments, some structures (Sartorius muscle) cross borders between compartments. Immobile joints (SI-joints, osteoarthritic hip) are relatively easily crossed by sarcoma and giant cell tumor.

  1. Outcomes of dual mobility components in total hip arthroplasty: a systematic review of the literature.

    Science.gov (United States)

    Darrith, B; Courtney, P M; Della Valle, C J

    2018-01-01

    Instability remains a challenging problem in both primary and revision total hip arthroplasty (THA). Dual mobility components confer increased stability, but there are concerns about the unique complications associated with these designs, as well as the long-term survivorship. We performed a systematic review of all English language articles dealing with dual mobility THAs published between 2007 and 2016 in the MEDLINE and Embase electronic databases. A total of 54 articles met inclusion criteria for the final analysis of primary and revision dual mobility THAs and dual mobility THAs used in the treatment of fractures of the femoral neck. We analysed the survivorship and rates of aseptic loosening and of intraprosthetic and extra-articular dislocation. For the 10 783 primary dual mobility THAs, the incidence of aseptic loosening was 1.3% (142 hips); the rate of intraprosthetic dislocation was 1.1% (122 hips) and the incidence of extra-articular dislocation was 0.46% (41 hips). The overall survivorship of the acetabular component and the dual mobility components was 98.0%, with all-cause revision as the endpoint at a mean follow-up of 8.5 years (2 to 16.5). For the 3008 revision dual mobility THAs, the rate of aseptic acetabular loosening was 1.4% (29 hips); the rate of intraprosthetic dislocation was 0.3% (eight hips) and the rate of extra-articular dislocation was 2.2% (67 hips). The survivorship of the acatabular and dual mobility components was 96.6% at a mean of 5.4 years (2 to 8). For the 554 dual mobility THAs which were undertaken in patients with a fracture of the femoral neck, the rate of intraprosthetic dislocation was 0.18% (one hip), the rate of extra-articular dislocation was 2.3% (13 hips) and there was one aseptic loosening. The survivorship was 97.8% at a mean of 1.3 years (0.75 to 2). Dual mobility articulations are a viable alternative to traditional bearing surfaces, with low rates of instability and good overall survivorship in primary and

  2. Influence of Minimally Invasive Total Hip Replacement on Hip Reaction Forces and Their Orientations

    NARCIS (Netherlands)

    Weber, Tim; Al-Munajjed, Amir A.; Verkerke, Gijsbertus Jacob; Dendorfer, Sebastian; Renkawitz, Tobias

    2014-01-01

    Minimally invasive surgery (MIS) is becoming increasingly popular. Supporters claim that the main advantages of MIS total hip replacement (THR) are less pain and a faster rehabilitation and recovery. Critics claim that safety and efficacy of MIS are yet to be determined. We focused on a

  3. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  4. Femoral nerve palsy caused by ileopectineal bursitis after total hip replacement: a case report

    Directory of Open Access Journals (Sweden)

    Bähr Mathias

    2011-05-01

    Full Text Available Abstract Introduction Infectious ileopectineal bursitis is a rare complication after total hip replacement and is associated mainly with rheumatoid arthritis. The main complications are local swelling and pain, but communication of the inflamed bursa with the joint can occur, leading to subsequent cartilage damage and bone destruction. Case presentation We report a case of a 47-year-old Caucasian woman without rheumatoid arthritis who reported pain and palsy in her left leg almost one year after total hip replacement. She was diagnosed with an ileopectineal bursitis after total hip replacement, leading to femoral nerve palsy. The diagnosis was obtained by thorough clinical examination, the results of focused computed tomography and magnetic resonance imaging. Conclusion To the best of our knowledge, this is the first report of non-infectious ileopectineal bursitis in a patient without rheumatoid arthritis as a complication of total hip replacement. This rare case underlines the importance of proper neurologic examination of persistent conditions after orthopedic intervention in otherwise healthy individuals. We believe this case should be useful for a broad spectrum of medical specialties, including orthopedics, neurology, radiology, and general practice.

  5. Psychological factors as risk factors for poor hip function after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benditz A

    2017-02-01

    Full Text Available Achim Benditz,1 Petra Jansen,2 Jan Schaible,1 Christina Roll,1 Joachim Grifka,1 Jürgen Götz1 1Department of Orthopedics, University Medical Center Regensburg, Asklepios Klinikum Bad Abbach, Bad Abbach, 2Department of Sport Science, University of Regensburg, Regensburg, Germany Abstract: Recovery after total hip arthroplasty (THA is influenced by several psychological aspects, such as depression, anxiety, resilience, and personality traits. We hypothesized that preoperative depression impedes early functional outcome after THA (primary outcome measure. Additional objectives were perioperative changes in the psychological status and their influence on perioperative outcome. This observational study analyzed depression, anxiety, resilience, and personality traits in 50 patients after primary unilateral THA. Hip functionality was measured by means of the Harris Hip Score. Depression, state anxiety, and resilience were evaluated preoperatively as well as 1 and 5 weeks postoperatively. Trait anxiety and personality traits were measured once preoperatively. Patients with low depression and anxiety levels had significantly better outcomes with respect to early hip functionality. Resilience and personality traits did not relate to hip functionality. Depression and state anxiety levels significantly decreased within the 5-week stay in the acute and rehabilitation clinic, whereas resilience remained at the same level. Our study suggests that low depression and anxiety levels are positively related to early functionality after THA. Therefore, perioperative measurements of these factors seem to be useful to provide the best support for patients with risk factors. Keywords: total hip arthroplasty, psychological factors, depression, state anxiety, trait anxiety, resilience, personality traits

  6. Dual mobility total hip arthroplasty in hemiplegic patients

    Directory of Open Access Journals (Sweden)

    Henawy Ayman T.

    2017-01-01

    Full Text Available Introduction: The rate of cerebrovascular insults is increasing, currently leaving many patients with difficulties to maintain their balance due to muscular weakness and/or poor central control. Those patients are at risk of dislocation when total hip arthroplasty (THA is planned. Instability remains the most significant issue after primary THA especially in such groups of patients. The risk is more pronounced when other factors are added such as, older age, femoral neck fractures, avascular necrosis and/or hip osteoarthritis. Dual mobility cup (DMC is considered as a prosthesis with higher inherent stability that may help in such situation. In this patient series, we aimed to evaluate stability, clinical and radiological results of dual mobility THA done on the weak limb of hemiplegic patients. Methods: Twenty-four consecutive hemiplegic patients have undergone DMC with a mean age of 68 years. The indication for surgery was hip osteoarthritis in one third of the patients and femoral neck fractures in the remaining patients. Those patients were capable of walking prior to hospital admission despite weakness. Those patients were observed postoperatively for at least one year. Clinical results and complications were recorded. Results: After a minimum of one year, 91.6% of the patients have satisfactory results. No cases of hip or intraprosthetic dislocation were observed. Discussion: Dual mobility THA in the hemiplegic patients provides both efficacy and stability with good functional results.

  7. [Modern tribology in total hip arthroplasty: pros and cons].

    Science.gov (United States)

    Gómez-García, F

    2014-01-01

    The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.

  8. Patient Satisfaction Reporting After Total Hip Arthroplasty: A Systematic Review.

    Science.gov (United States)

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Schairer, William W; Steinhaus, Michael E; Cross, Michael B

    2017-05-01

    This review evaluated the quality of patient satisfaction reporting after total hip arthroplasty. The initial search of the MEDLINE database yielded 755 studies. Twenty-four met the inclusion criteria. Most studies provided level III or IV evidence (n=15, 62.5%). The most common method used to assess satisfaction was the 10-point visual analog scale (7 studies, 29.2%), followed by an ordinal satisfaction scale (6 studies, 25.0%). The quality of evidence was poor, and the methods used to assess satisfaction were not standardized. Further research is needed to define the factors that affect patient satisfaction after total hip arthroplasty and how satisfaction is best measured. [Orthopedics. 2017; 40(3):e400-e404.]. Copyright 2017, SLACK Incorporated.

  9. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  10. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, F.; Seufert, J.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Dept. of Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Krankenhaus Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Krankenhaus Bad Mergentheim (Germany). Inst. of Radiology

    2005-08-01

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  11. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    Science.gov (United States)

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  12. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    Science.gov (United States)

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important

  13. Heterotopic bone formation following total shoulder arthroplasty

    DEFF Research Database (Denmark)

    Kjaersgaard-Andersen, P.; Frich, Lars Henrik; Sjøbjerg, J.O.

    1989-01-01

    The incidence and location of heterotopic bone formation following total shoulder arthroplasty were evaluated in 58 Neer Mark-II total shoulder replacements. One year after surgery, 45% had developed some ectopic ossification. In six shoulders (10%) the ossifications roentgenographically bridged...... the glenohumeral and/or the glenoacromial space. There was no correlation between shoulder pain and the development of ossification. Shoulders with grade III heterotopic bone formation had a limited range of active elevation compared with shoulders without or with only a milder lesion. Men and patients...... with osteoarthritis of the shoulder joint were significantly disposed to the development of heterotopic bone. Heterotopic bone formation following total shoulder arthroplasty is frequent, but disabling heterotopic ossifications seem to be rare....

  14. The association between metal allergy, total hip arthroplasty, and revision

    DEFF Research Database (Denmark)

    Thyssen, Jacob Pontoppidan; Jakobsen, Stig Storgaard; Engkilde, Kåre

    2009-01-01

    BACKGROUND AND PURPOSE: It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following total hip arthroplasty (THA) in dermatitis patients suspected to have contact allergy and in patients...... in general with THA. Furthermore, we compared the prevalence of metal allergy in dermatitis patients with and without THA. MATERIALS AND METHODS: The Danish Hip Arthroplasty Registry (DHAR) contained detailed information on 90,697 operations. The Gentofte patch-test database contained test results...... was similar in cases (12%) and in patients from the DHAR (13%). The prevalence of metal allergy was similar in cases and controls. However, the prevalence of metal allergy was lower in cases who were patch-tested after operation (6%) than in those who were patch-tested before operation (16%) (OR = 2.9; 95% CI...

  15. Total Hip Arthroplasty – over 100 years of operative history

    Directory of Open Access Journals (Sweden)

    Stephen Richard Knight

    2011-11-01

    Full Text Available Total hip arthroplasty (THA has completely revolutionised the nature in which the arthritic hip is treated, and is considered to be one of the most successful orthopaedic interventions of its generation (1. With over 100 years of operative history, this review examines the progression of the operation from its origins, together with highlighting the materials and techniques that have contributed to its development. Knowledge of its history contributes to a greater understanding of THA, such as the reasons behind selection of prosthetic materials in certain patient groups, while demonstrating the importance of critically analyzing research to continually determine best operative practice. Finally, we describe current areas of research being undertaken to further advance techniques and improve outcomes.

  16. Clinical Outcomes and 90-Day Costs Following Hemiarthroplasty or Total Hip Arthroplasty for Hip Fracture.

    Science.gov (United States)

    Nichols, Christine I; Vose, Joshua G; Nunley, Ryan M

    2017-09-01

    In the era of bundled payments, many hospitals are responsible for costs from admission through 90 days postdischarge. Although bundled episodes for hip fracture will have a separate target price for the bundle, little is known about the 90-day resource use burden for this patient population. Using Medicare 100% Standard Analytic Files (2010-2014), we identified patients undergoing hemiarthroplasty or total hip arthroplasty (THA). Patients were aged 65 and older with admitting diagnosis of closed hip fracture, no concurrent fractures of the lower limb, and no history of hip surgery in the prior 12 months baseline. Continuous Medicare-only enrollment was required. Complications, resource use, and mortality from admission through 90 days following discharge (follow-up) were summarized. Four cohorts met selection criteria for analysis: (1) hemiarthroplasty diagnosis-related group (DRG) 469 (N = 19,634), (2) hemiarthroplasty DRG 470 (N = 77,744), (3) THA DRG 469 (N = 1686), and (4) THA DRG 470 (N = 9314). All-cause mortality during the study period was 51.6%, 29.5%, 48.1%, and 24.9% with mean 90-day costs of $28,952, $19,243, $29,763, and $18,561, respectively. Most of the patients waited 1 day from admission to surgery (41%-51%). Incidence of an all-cause complication was approximately 70% in each DRG 469 cohort and 14%-16% in each DRG 470 cohort. This study confirms patients with hip fracture are a costly subpopulation. Tailored care pathways to minimize post-acute care resource use are warranted for these patients. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  17. Cost of Radiotherapy Versus NSAID Administration for Prevention of Heterotopic Ossification After Total Hip Arthroplasty

    International Nuclear Information System (INIS)

    Strauss, Jonathan B.; Chen, Sea S.; Shah, Anand P.; Coon, Alan B.; Dickler, Adam

    2008-01-01

    Purpose: Heterotopic ossification (HO), or abnormal bone formation, is a common sequela of total hip arthroplasty. This abnormal bone can impair joint function and must be surgically removed to restore mobility. HO can be prevented by postoperative nonsteroidal anti-inflammatory drug (NSAID) use or radiotherapy (RT). NSAIDs are associated with multiple toxicities, including gastrointestinal bleeding. Although RT has been shown to be more efficacious than NSAIDs at preventing HO, its cost-effectiveness has been questioned. Methods and Materials: We performed an analysis of the cost of postoperative RT to the hip compared with NSAID administration, taking into account the costs of surgery for HO formation, treatment-induced morbidity, and productivity loss from missed work. The costs of RT, surgical revision, and treatment of gastrointestinal bleeding were estimated using the 2007 Medicare Fee Schedule and inpatient diagnosis-related group codes. The cost of lost wages was estimated using the 2006 median salary data from the U.S. Census Bureau. Results: The cost of administering RT was estimated at $899 vs. $20 for NSAID use. After accounting for the additional costs associated with revision total hip arthroplasty and gastrointestinal bleeding, the corresponding estimated costs were $1,208 vs. $930. Conclusion: If the costs associated with treatment failure and treatment-induced morbidity are considered, the cost of NSAIDs approaches that of RT. Other NSAID morbidities and quality-of-life differences that are difficult to quantify add to the cost of NSAIDs. These considerations have led us to recommend RT as the preferred modality for use in prophylaxis against HO after total hip arthroplasty, even when the cost is considered

  18. Postoperative radiotherapy prophylaxis of periarticular ossification after total hip replacement

    International Nuclear Information System (INIS)

    Sauer, R.; Seegenschmiedt, M.H.; Andreas, P.; Goldmann, A.; Beck, H.

    1992-01-01

    Since June 1988, we have treated 77 patients or 80 hips respectively with prophylactic irradiation. Individual risk factors included severe coxarthrosis grade IV, ipsi- or contralateral heterotopic ossification and severe hip trauma. As of July 1991 60 patients with a minimum follow-up of six months could be analyzed using clinical and radiological scoring systems. The patients had been prospectively randomized in two different treatment arms: 32 patients were treated with low dose (LD), five times 2 Gy daily fractions to a total dose of 10 Gy, whereas 28 patients were treated with high dose (HD), ten times 2 Gy (eight patients) or five times 3.5 Gy (20 patients). Operative procedures and individual risk factors were equally distributed in both groups. 23 patients (38% received indometacin three times 25 mg for six weeks, 19 patients (32%) diphosphonate EHDP 20 mg/kg body weight and 18 patients (30%) had no additional medication. 56/60 (93%) patients developed no significant heterotopic ossification and/or remained without impairment of their postoperative radiological and clinical hip status according to the applied Brooker and Harris Scores. Only 4/60 (7%) patients demonstrated treatment failures developing postoperative worsening one grade of Brooker score in two patients and two and three grades of Brooker score in the two others. Only 1/49 patients experienced a treatment failure, when radiotherapy had been initiated before and at postoperative day 4 compared to 3/11 patients initiated after postoperative day 4 (p [de

  19. Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis

    Science.gov (United States)

    Chin, Garwin; Wright, David J.; Snir, Nimrod; Schwarzkopf, Ran

    2018-01-01

    Introduction Increasing hip fracture incidence in the United States is leading to higher occurrences of conversion total hip arthroplasty (THA) for failed surgical treatment of the hip. In spite of studies showing higher complication rates in conversion THA, the Centers for Medicare and Medicaid services currently bundles conversion and primary THA under the same diagnosis-related group. We examined the cost of treatment of conversion THA compared with primary THA. Our hypothesis is that conversion THA will have higher cost and resource use than primary THA. Methods Fifty-one consecutive conversion THA patients (Current Procedure Terminology code 27132) and 105 matched primary THA patients (Current Procedure Terminology code 27130) were included in this study. The natural log-transformed costs for conversion and primary THA were compared using regression analysis. Age, gender, body mass index, American Society of Anesthesiologist, Charlson comorbidity score, and smoker status were controlled in the analysis. Conversion THA subgroups formed based on etiology were compared using analysis of variance analysis. Results Conversion and primary THAs were determined to be significantly different (P conversion THA has significantly greater cost and resource use than primary THA. In order to prevent disincentives for treating these complex surgical patients, reclassification of conversion THA is needed, as they do not fit together with primary THA. PMID:26387923

  20. Does total hip replacement affect sexual quality of life?

    Science.gov (United States)

    Harmsen, Rita Th E; Haanstra, Tsjitske M; Sierevelt, Inger N; Jansma, Elise P; Nolte, Peter A; Nicolai, Melianthe P J; Wall, Peter D H; Van Royen, Barend J

    2016-05-04

    Total Hip Replacement (THR) is an effective treatment for end-stage hip osteoarthritis. Since the introduction of total joint replacement, the effect on the Sexual Quality of Life (SQoL) following THR has been addressed in scant studies. The aim of our study was to systematically review the literature, to summarise effects of THR on patients' SQoL. We searched PubMed, EMBASE and PsycINFO between January 1970 and February 9th, 2015 with search terms including Total Hip, Osteoarthritis, SQoL, and THR. Eligible studies were identified and two independent authors extracted data including details of SQoL, study quality and risk of bias. There were 12 eligible studies, which included a total of 2099 patients with an age range of 20-85 years. The methodological quality of ten studies was rated as low, and of two as moderate. Amongst the majority of patients, SQoL improved after surgery, both in terms of physical-functional and psychosocial well-being. However, changes between pre-operative and postoperative SQoL ranged extensively: for example, Sexual Dysfunction Δ 8-51% and Sexual Activity (SA) Δ 0-77%. Three studies reported that some patients never resumed SA again after surgery. In over 40 years of THR treatment, scant studies have examined the effect of THR on patients' SQoL. This review suggests that SQol improves after THR, although the magnitude of effects varies highly. However, the quality of the supporting evidence was rated as low to moderate. This suggests a need for more high quality evidence about the effects of THR on SQoL.

  1. Trochantoplasty for Total Hip Arthroplasty in Patients With Coxa Vara Deformity.

    Science.gov (United States)

    Yoo, Jun-Il; Parvizi, Javad; Song, Ji-Ung; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2017-07-01

    In total hip arthroplasty (THA) of hips with coxa vara, the femoral stems might be inserted in a varus alignment. To avoid varus insertion, we designed a technique, which we termed "trochantoplasty." In this procedure, the medial half of the greater trochanter was removed during THA. We evaluated 30 patients (31 hips) who had coxa vara deformity and underwent THA using trochantoplasty at the mean follow-up of 5 years (range, 3-9 years). All stems were inserted in the neutral position. One Vancouver type 1 periprosthetic femoral fracture occurred after a fall at postoperative 2 months. At the latest follow-up, the mean power of abductor was 4.3 (range, 3-5). Four patients had moderate limp whereas 26 patients had slight limp. The abduction at 90° flexion ranged from 15° to 45° (mean, 35°). There was no revision. All prostheses had bone-ingrown stability without any detectable wear or osteolysis. The mean Harris hip score was improved from 66.9 to 89.4 points. Trochantoplasty can be used to avoid varus insertion of the femoral stem while performing THA in patients with coxa vara deformity without compromising the abductor mechanism. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    International Nuclear Information System (INIS)

    Alexander, J.E.; Seibert, J.J.; Aronson, J.; Williamson, S.L.; Glasier, C.M.; Rodgers, A.B.; Corbitt, S.L.

    1988-01-01

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck

  3. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip......-joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...

  4. Pain and somatosensory findings in patients 3 years after total hip arthroplasty

    DEFF Research Database (Denmark)

    Nikolajsen, Lone; Kristensen, Anders D; Thillemann, Theis M

    2009-01-01

    in patients and controls. Patients with chronic hip pain had higher scores on the mental vulnerability scale (Poperated side, which was more prominent in patients...... with chronic hip pain and 18 controls without chronic hip pain were recruited from a previous questionnaire study about hip pain after total hip arthroplasty. All participants answered questions about pain and mental vulnerability and underwent clinical examination followed by quantitative sensory testing...... with pain. Pain referred from the back or deeper structures in the hip seems to play a role for the pain in subgroups of patients. In addition, chronic hip pain was associated with mental vulnerability....

  5. Intake of omega-3 fatty acids contributes to bone mineral density at the hip in a younger Japanese female population.

    Science.gov (United States)

    Kuroda, T; Ohta, H; Onoe, Y; Tsugawa, N; Shiraki, M

    2017-10-01

    This study investigated the relationships between intakes of polyunsaturated fatty acids, omega-3 fatty acids, and omega-6 fatty acids and bone mineral density in Japanese women aged 19 to 25 years. Intakes of omega-3 fatty acids (n-3) were positively associated with peak bone mass at the hip. Lifestyle factors such as physical activity and nutrition intake are known to optimize the peak bone mass (PBM). Recently, intake of polyunsaturated fatty acids (PUFAs) has been reported to contribute to bone metabolism. In this study, the relationships of intakes of n-3 and omega-6 (n-6) fatty acids with PBM were evaluated in Japanese female subjects. A total of 275 healthy female subjects (19-25 years) having PBM were enrolled, and lumbar and total hip bone mineral density (BMD) and bone metabolic parameters were measured. Dietary intakes of total energy, total n-3 fatty acids, eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and total n-6 fatty acids were assessed by a self-administered questionnaire. Physical activity information was also assessed. The mean ± SD age was 20.6 ± 1.4 years, and BMI was 21.2 ± 2.7 kg/m 2 . BMI and serum bone alkaline phosphatase contributed significantly to lumbar BMD on multiple regression analysis. Intake of n-3 fatty acids and physical activity were also significantly related to total hip BMD. Using EPA or DHA instead of total n-3 fatty acids in the model did not result in a significant result. Adequate total n-3 fatty acid intake may help maximize PBM at the hip.

  6. The current state of bearing surfaces in total hip replacement.

    Science.gov (United States)

    Rajpura, A; Kendoff, D; Board, T N

    2014-02-01

    We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual's functional demands.

  7. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  8. Oral bisphosphonate use and total knee/hip implant survival

    DEFF Research Database (Denmark)

    Prieto-Alhambra, Daniel; Lalmohamed, Arief; Abrahamsen, Bo

    2014-01-01

    of disease-modifying antirheumatic drugs as well as patients with rheumatoid arthritis, Paget's disease, or hip fracture. Participants were classified as bisphosphonate users if they had been receiving treatment for ≥6 months. A time-varying exposure was used to avoid immortal time bias. Up to 6...... was conducted within the Danish nationwide registries (5.5 million residents). Using procedure codes of the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision, we identified patients age ≥40 years undergoing total joint replacement in 1998-2007. We excluded users...

  9. Reliability of using DXA around RTHAs. Bone Mineral Density of the femoral neck in resurfacing hip arthroplasty

    DEFF Research Database (Denmark)

    Penny, Jeannette Østergaard; Ovesen, Ole; Brixen, Kim

    2010-01-01

      Background and purpose: Resurfacing Total Hip Arthroplasty (RTHA) may preserve the femoral neck bone-stock post-operatively. Bone Mineral Density (BMD), could theoretically be affected by the hip-position, and bias longitudinal studies. We aimed to investigate BMD precision dependency on type...... was rotated in increments of 15° and 30°, the mean CVs rose to 7.2%, 7.3% and 11.8%.  Rotation affected the precision most in the model that divided the neck in 6 sub regions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising...

  10. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    Science.gov (United States)

    Rozkydal, Z; Janíček, P

    2010-08-01

    -Čech stem with its anatomical shape and a highly polished surface meets the principles of successful composite beam stems. Its disadvantage is a valgus neck- shaft angle of 140° giving lower femoral offset and the risk of development of valgus deformity of the ipsilateral knee. In most cases osteolysis, radiolucent lines and bone rarefaction of the femur resulted from polyethylene wear of the acetabular component. This study demonstrates a long-term survivorship of the Poldi-Čech femoral component in patients undergoing total hip arthroplasty 25 to 35 years ago.

  11. Drinking water fluoridation: bone mineral density and hip fracture incidence.

    Science.gov (United States)

    Lehmann, R; Wapniarz, M; Hofmann, B; Pieper, B; Haubitz, I; Allolio, B

    1998-03-01

    The role of drinking water fluoride content for prevention of osteoporosis remains controversial. Therefore, we analyzed the influence of drinking water fluoridation on the incidence of osteoporotic hip fractures and bone mineral density (BMD) in two different communities in eastern Germany: in Chemnitz, drinking water was fluoridated (1 mg/L) over a period of 30 years; in Halle, the water was not fluoridated. BMD was measured in healthy hospital employees aged 20-60 years (Halle: 214 women, 98 men; Chemnitz: 201 women, 43 men, respectively) using dual-energy X-ray absorptiometry. Hip fractures in patients > or = 35 years admitted to the local hospitals in the years 1987-1989 were collected from the clinic registers. There was no difference in age, anthropometric, hormonal, or lifestyle variables between the two groups. Mean fluoride exposure in Chemnitz was 25.2 +/- 7.3 years. No correlation was found between fluoride exposure and age-adjusted BMD. We found no significant difference in spinal or femoral BMD between subjects living in Halle and Chemnitz [lumbar spine: 0.997 +/- 0.129 (g/cm2) vs. 1.045 + 0.171 (g/cm2), p = 0.08, for men; 1.055 +/- 0.112 (g/cm2) vs. 1.046 +/- 0.117 (g/cm2), p = 0.47, for women]. The fracture incidence showed an exponential increase with aging in men and women with an incidence about 3.5 times higher for women. In Chemnitz, we calculated an age-adjusted annual incidence of 142.2 per 100,000 for women and 72.5 per 100,000 for men, respectively. In Halle, the incidences were 178.5 per 100,000 for women and 89.2 per 100,000 for men. There was a lower hip fracture incidence after the age of 85 in women in Chemnitz (1391 per 100,000 in Chemnitz vs. 1957 per 100,000) in Halle, p = 0.006). Using the age-adjusted incidences, significantly fewer hip fractures occurred in Chemnitz in both men and women. In conclusion, our study suggests that optimal drinking water fluoridation (1 mg/L), which is advocated for prevention of dental caries, does

  12. Total Hip Arthroplasty in Patients With Avascular Necrosis After Hematopoietic Stem Cell Transplantation.

    Science.gov (United States)

    Vijapura, Anita; Levine, Harlan B; Donato, Michele; Hartzband, Mark A; Baker, Melissa; Klein, Gregg R

    2018-03-01

    The immunosuppressive regimens required for hematopoietic stem cell transplantation predispose recipients to complications, including avascular necrosis. Cancer-related comorbidities, immunosuppression, and poor bone quality theoretically increase the risk for perioperative medical complications, infection, and implant-related complications in total joint arthroplasty. This study reviewed 20 primary total hip arthroplasties for avascular necrosis in 14 patients. Outcomes were assessed at routine clinical visits and Harris hip scores were calculated. Follow-up radiographs were evaluated for component malposition, loosening, polyethylene wear, and osteolysis. Average follow-up was 44.5 months for all patients. Postoperative clinical follow-up revealed good to excellent outcomes, with significant improvement in functional outcome scores. There were no periprosthetic infections or revisions for aseptic loosening. There was 1 dislocation on postoperative day 40, which was treated successfully with a closed reduction. Two patients with a prior history of venous thromboembolism developed a pulmonary embolus on postoperative day 13 and 77, respectively. Four patients died several months to years after arthroplasty of complications unrelated to the surgical procedure. Total hip arthroplasty can both be safely performed and greatly improve quality of life in recipients of hematopoietic stem cell transplantation who develop avascular necrosis. However, prolonged venous thromboembolism prophylaxis should be carefully considered in this high-risk patient population. [Orthopedics. 2018; 41(2):e257-e261.]. Copyright 2018, SLACK Incorporated.

  13. Allogenic blood transfusion following total hip arthroplasty: results from the nationwide inpatient sample, 2000 to 2009.

    Science.gov (United States)

    Saleh, Anas; Small, Travis; Chandran Pillai, Aiswarya Lekshmi Pillai; Schiltz, Nicholas K; Klika, Alison K; Barsoum, Wael K

    2014-09-17

    The large-scale utilization of allogenic blood transfusion and its associated outcomes have been described in critically ill patients and those undergoing high-risk cardiac surgery but not in patients undergoing elective total hip arthroplasty. The objective of this study was to determine the trends in utilization and outcomes of allogenic blood transfusion in patients undergoing primary total hip arthroplasty in the United States from 2000 to 2009. An observational cohort of 2,087,423 patients who underwent primary total hip arthroplasty from 2000 to 2009 was identified in the Nationwide Inpatient Sample. International Classification of Diseases, Ninth Revision, Clinical Modification procedure codes 99.03 and 99.04 were used to identify patients who received allogenic blood products during their hospital stay. Risk factors for allogenic transfusions were identified with use of multivariable logistic regression models. We used propensity score matching to estimate the adjusted association between transfusion and surgical outcomes. The rate of allogenic blood transfusion increased from 11.8% in 2000 to 19.0% in 2009. Patient-related risk factors for receiving an allogenic blood transfusion include an older age, female sex, black race, and Medicaid insurance. Hospital-related risk factors include rural location, smaller size, and non-academic status. After adjusting for confounders, allogenic blood transfusion was associated with a longer hospital stay (0.58 ± 0.02 day; p conservation methods. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  14. [Total knee and hip prosthesis: variables associated with costs].

    Science.gov (United States)

    Herrera-Espiñeira, Carmen; Escobar, Antonio; Navarro-Espigares, José Luis; Castillo, Juan de Dios Lunadel; García-Pérez, Lidia; Godoy-Montijano, Amparo

    2013-01-01

    The elevated prevalence of osteoarthritis in Western countries, the high costs of hip and knee arthroplasty, and the wide variations in the clinical practice have generated considerable interest in comparing the associated costs before and after surgery. To determine the influence of a number of variables on the costs of total knee and hip arthroplasty surgery during the hospital stay and during the one-year post-discharge. A prospective multi-center study was performed in 15 hospitals from three Spanish regions. Relationships between the independent variables and the costs of hospital stay and postdischarge follow-up were analyzed by using multilevel models in which the "hospital" variable was used to group cases. Independent variables were: age, sex, body mass index, preoperative quality of life (SF-12, EQ-5 and Womac questionnaires), surgery (hip/knee), Charlson Index, general and local complications, number of beds and economic-institutional dependency of the hospital, the autonomous region to which it belongs, and the presence of a caregiver. The cost of hospital stay, excluding the cost of the prosthesis, was 4,734 Euros, and the post-discharge cost was 554 Euros. With regard to hospital stay costs, the variance among hospitals explained 44-46% of the total variance among the patients. With regard to the post-discharge costs, the variability among hospitals explained 7-9% of the variance among the patients. There is considerable potential for reducing the hospital stay costs of these patients, given that more than 44% of the observed variability was not determined by the clinical conditions of the patients but rather by the behavior of the hospitals.

  15. Increased body mass index is a predisposition for treatment by total hip replacement

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    -joint degeneration and dysplasia. Sequential body mass index (BMI) measurements from 1976 to 1992, age, exposure to daily lifting and hip dysplasia were entered into logistic regression analyses. The prevalence of hip dysplasia ranged from 5.4% to 12.8% depending on the radiographical index used. Radiological hip OA...... prevalence was 1.0--2.5% in subjects or=60 years of age. While radiological OA was significantly influenced by hip dysplasia in men and hip dysplasia and age in women, the risk of THR being performed was only influenced by BMI assessed in 1976. Hip......We investigated the radiological and epidemiological data of 4,151 subjects followed up from 1976 to 2003 to determine individual risk factors for hip osteoarthritis (OA), hip pain and/or treatment by total hip replacement (THR). Pelvic radiographs recorded in 1992 were assessed for evidence of hip...

  16. Sequential use of technetium 99m MDP and gallium 67 citrate imaging in the evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Horoszowski, H.; Ganel, A.; Kamhin, M.; Zaltman, S.; Farine, I.

    1980-01-01

    Fourteen patients with 20 total hip joint replacements were studied for 14 painful prosthetic hips. Clinical examination, plain film radiographs and 99 Tcsup(m)-methylene diphosphonate bone scans failed to differentiate between infection and mechanical loosening of a prosthesis. Sequential use of 99 Tcsup(m)-methylene diphosphonate and 67 Ga-citrate bone scans were performed in an attempt to discover underlying infectious process. Increased focal uptake of both radiopharmaceuticals over the same hip indicated an infectious process responsible for prosthetic loosening. There were no false positive gallium examinations. Sequential use of 99 Tcsup(m)-phosphate compounds and 67 Ga-citrate is recommended for differentiation between mechanical loosening of a prosthesis and loosening of a prosthesis secondary to an infectious process. (U.K.)

  17. Dietary patterns and longitudinal change in hip bone mineral density among older men.

    Science.gov (United States)

    Rogers, T S; Harrison, S; Judd, S; Orwoll, E S; Marshall, L M; Shannon, J; Langsetmo, L; Lane, N E; Shikany, J M

    2018-05-01

    Studying dietary patterns is often more informative than individual nutrients or foods. We found that a Prudent dietary pattern (rich in vegetables and fish) was associated with reduced loss of total hip BMD in older men. A Prudent dietary pattern may be a potential lifestyle strategy for minimizing bone loss. This study aimed to identify baseline dietary patterns using factor analysis in a cohort of older men and to evaluate whether the dietary patterns were associated with bone mineral density change (%ΔBMD) at the total hip and femoral neck over time. Participants (n = 4379; mean age 72.9 ± 5.5 years) were from the Osteoporotic Fractures in Men (MrOS) prospective cohort study and had dietary data collected at baseline (March 2000-April 2002) and BMD measured at baseline and Visit 2 (March 2005-May 2006). Dietary intake was assessed with a brief Block food frequency questionnaire (FFQ); factor analysis was used to derive dietary patterns. BMD was measured by dual-energy x-ray absorptiometry (DXA); %ΔBMD was calculated from baseline to Visit 2. We used generalized linear regression to estimate least square (LS) means of %ΔBMD in quartiles of the dietary pattern scores adjusted for potential confounding factors. Two major dietary patterns were derived: Prudent (abundant in vegetables, salad, and non-fried fish) and Western (rich in hamburger, fries, processed meats, cheese, and sweets/desserts). There was an inverse association between adherence to the Prudent pattern and total hip %ΔBMD (p-trend = 0.028 after adjusting for age and clinical site; p-trend = 0.033 after further adjustment for smoking, calcium supplement use, diabetes, hypertension, and total energy intake). No other consistent associations between dietary patterns and %ΔBMD were observed. Greater adherence to a Prudent dietary pattern may attenuate total hip BMD loss (%ΔBMD) in older men.

  18. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir

    2012-01-01

    Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods The...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA.......Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods...... The study was based on the Nordic Arthroplasty Register Association (NARA) dataset. 432,168 primary THAs from 1995 to 2009 were included (Denmark: 83,853, Finland 78,106, Norway 88,455, and Sweden 181,754). Adjusted survival analyses were performed using Cox regression models with revision due to infection...

  19. Relationship between MRI-measured bone marrow adipose tissue and hip and spine bone mineral density in African-American and Caucasian participants: the CARDIA study.

    Science.gov (United States)

    Shen, Wei; Scherzer, Rebecca; Gantz, Madeleine; Chen, Jun; Punyanitya, Mark; Lewis, Cora E; Grunfeld, Carl

    2012-04-01

    An increasing number of studies suggest that bone marrow adipose tissue (BMAT) might play a role in the pathogenesis of osteoporosis. Our previous study of Caucasian women demonstrated that there is an inverse relationship between BMAT and whole-body bone mineral density (BMD). It is unknown whether visceral adipose tissue (VAT), sc adipose tissue (SAT), and skeletal muscle had an effect on the relationship between BMAT and BMD. In the present study we investigated the relationship between pelvic, hip, and lumbar spine BMAT with hip and lumbar spine BMD in the population-based Coronary Artery Risk Development in Young Adults (CARDIA) sample with adjustment for whole-body magnetic resonance imaging (MRI)-measured VAT, SAT, and skeletal muscle. T1-weighted MRI was acquired for 210 healthy African-American and Caucasian men and women (age 38-52 yr). Hip and lumbar spine BMD were measured by dual-energy x-ray absorptiometry. Pelvic, hip, and lumbar spine BMAT had negative correlations with hip and lumbar spine BMD (r = -0.399 to -0.550, P BMAT and BMD remained strong after adjusting for demographics, weight, skeletal muscle, SAT, VAT, total adipose tissue (TAT), menopausal status, lifestyle factors, and inflammatory markers (standardized regression coefficients = -0. 296 to -0.549, P BMAT (standardized regression coefficients = 0.268-0.614, P BMAT and hip and lumbar spine BMD independent of demographics and body composition. These observations support the growing evidence linking BMAT with low bone density.

  20. Migratory Bone Marrow Edema Syndrome of the Hips: A Case Report

    Directory of Open Access Journals (Sweden)

    Santoso A

    2017-11-01

    Full Text Available Migratory bone marrow edema syndrome (BMES of the hip is a rare entity. We report the case of a 41-year old male with migratory BMES of the hip with eight months interval period between onset of the pain and consultation. This patient was successfully treated non-surgically. It is important to always inform the patient with unilateral BMES of the hip regarding the possibility of future involvement of the contralateral hip.

  1. Preoperative therapeutic exercise in frail elderly scheduled for total hip replacement: A randomized pilot trial

    NARCIS (Netherlands)

    Hoogeboom, T.J.; Dronkers, J.J.; Ende, C.H.M. van den; Oosting, E.; Meeteren, N.L.U. van

    2010-01-01

    Objective: To evaluate the feasibility and preliminary effectiveness of therapeutic exercise before total hip replacement in frail elderly. Design: A single-blind, randomized clinical pilot trial. Setting: Outpatient physiotherapy department. Subjects: Frail elderly with hip osteoarthritis awaiting

  2. Revision total hip arthoplasty: factors associated with re-revision surgery.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A

    2015-03-04

    highly cross-linked polyethylene bearing articulation decreases the hazard relative to metal on highly cross-linked polyethylene by a factor of 0.32 (95% confidence interval, 0.11 to 0.95). Metal on constrained bearing increases the hazard relative to metal on highly cross-linked polyethylene by a factor of 3.32 (95% confidence interval, 1.16 to 9.48). When evaluating patient, implant, and surgical factors at the time of revision total hip arthroplasty, age, surgeon experience, implant fixation, and bearing surfaces had significant impacts on the risk of re-revision. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Nursing in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Specht, Kirsten; Kjaersgaard-Andersen, Per; Kehlet, Henrik

    2015-01-01

    must still focus on the individual patient. Nurses need to have enough education to manage the complex tasks and increased responsibility. To prevent undesirable outcomes in the future, there is a need to pay attention to the nursing quality in balance with the nursing budget. It may, therefore......AIM: To describe the increased activity in total hip arthroplasty (THA) and total knee arthroplasty (TKA) from 2002 to 2012 in a single orthopaedic department, the organisation of fast-track and its consequences for nursing care. METHODS: Retrospective, descriptive design. Data collection; from...... gained tasks from surgeons and physiotherapists and thus gained more responsibility, for example, for pain management and mobilisation. Staffing levels in the ward in 2002 and 2012 were almost unchanged; 16.0 and 15.8 respectively. Nurses were undertaking more complicated tasks. CONCLUSION: Nursing care...

  4. Patient-reported outcome of hip resurfacing arthroplasty and standard total hip replacement after short-term follow-up

    DEFF Research Database (Denmark)

    Nissen, Nina; Douw, Karla; Overgaard, Søren

    2011-01-01

    The purpose of this study was to investigate patientreported outcome in terms of satisfaction in two study groups that had undergone hip resurfacing arthro-plasty (HRA) or total hip replacement (THR). The procedure consists of placing a hollow, mushroom-shaped metal cap over the femoral head whil...... a matching metal cup is placed in the acetabulum (pelvis socket)....

  5. Improving stress shielding following total hip arthroplasty by using a femoral stem made of β type Ti-33.6Nb-4Sn with a Young's modulus gradation

    NARCIS (Netherlands)

    Yamako, Go; Janssen, Dennis; Hanada, Shuji; Anijs, Thomas; Ochiai, Kiyohide; Totoribe, Koji; Chosa, Etsuo; Verdonschot, Nico

    2017-01-01

    Stress shielding-related bone loss occurs after total hip arthroplasty because the stiffness of metallic implants differs from that of the host femur. Although reducing stem stiffness can ameliorate the bone resorption, it increases stress at the bone–implant interface and can inhibit fixation. To

  6. The innovation trap: modular neck in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Samo Karel Fokter

    2017-04-01

    Full Text Available Background: Innovations play the key role in the success of orthopaedic surgery. However, even minor modifications in the established concepts and proven designs may result in disasters. The endemic of modular femoral neck fracture (24 cases of about 4000 implanted in fully modular total hip arthroplasty, popular in our country for the last 20 years, seems to challenge us with such an unfortunate consequences. The aim of this report was to analyze the extent and the causes of the problem on the one hand and to propose possible solutions on the other.Methods: Literature search for problems associated with Profemur Z (or earlier versions with the same taper-cone design fully-modular femoral stem made of titanium alloy (Ti6Al4V was performed, and hip arthroplasty registries were searched to evaluate the failure rates of the mentioned design. Mechanisms of failure were studied to get in-depth understanding of this particular hip reconstruction device.Results: Since 2010 onwards, several case reports on catastrophic modular femoral neck fractures of Profemur Z were published. Te frst Slovenian case was described in 2012. The first two larger series with modular femoral neck fractures were published in 2016. Te Australian Joint Replacement Registry was the first to discover increased revision rates due to fractures of this hip reconstruction system. Public Agency of the Republic of Slovenia for Medicinal Products and Medical Devices (JAZMP received frst two reports regarding Profemur Z modular neck complication from abroad in 2010, the first Slovenian report was received in 2012, and altogether 7 reports from Slovenian hospitals were received until December 2016. Corrosion at the neck-taper interface, where two equal or different materials are subject to constant wear in the presence of body fluids, is assumed to be responsible for the unacceptable high failure rate.Conclusions: Manufacturers are responsible to produce and market only safe devices

  7. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  8. Unusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process

    Directory of Open Access Journals (Sweden)

    Robert P. Runner, MD

    2017-06-01

    Full Text Available Metal-on-metal (MoM total hip arthroplasty (THA is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, concerning for periprosthetic malignancy. Open frozen section biopsy was performed before undergoing revision THA in a single episode of care. This case illustrates that massive pseudotumors can be locally aggressive causing significant femoral bone destruction and may mimic malignancy. It is important that orthopaedic surgeons, radiologists and pathologists understand the relative infrequency of periprosthetic malignancy in MoM THA to mitigate patient concerns, misdiagnosis, and allow for an evidence based discussion when treating massive pseudotumors.

  9. Resumption of car driving after total hip replacement.

    Science.gov (United States)

    Abbas, Ghulam; Waheed, Abdul

    2011-04-01

    To assess periods required for resuming car driving in 130 patients who had undergone total hip replacement (THR). 80 men and 50 women aged 39 to 80 years who had been driving automatic (n=49) or manual (n=81) cars in the previous 3 months and underwent unilateral primary THR of the right (n=85) or left (n=45) hip were recruited. Patients were advised to resume driving after 6 weeks if they felt comfortable to do so. 105 (81%) patients were able to resume driving at week 6 to 8; 67 (64%) had had a right THR and 65 (62%) were manual car drivers. 22 (17%) patients were able to do so at week 12. The remaining 3 (2%) patients were not confident to drive even at week 12. No patient reported deterioration in driving ability, whereas 48 (38%) felt a subjective improvement in their driving ability. The time to resume driving varies in different patients. The advice should be individualised, depending on the patient's recovery and confidence level.

  10. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  11. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  12. Ultraviolet radiation and air contamination during total hip replacement

    International Nuclear Information System (INIS)

    Carlsson, A.S.; Nilsson, B.; Walder, M.H.; Osterberg, K.

    1986-01-01

    Ultraviolet (uv) radiation of the operating room was assessed bacteriologically in an open randomized study of 30 total hip procedures. Volumetric air-sampling demonstrated that the number of colony forming units (cfu m-3) were significantly reduced (P less than 0.001) by uv light, both close to the wound and in the periphery of the operating room. No adverse effects of the uv-irradiation were observed either in the patients or the staff. In operating rooms fitted with a zonal ventilation system and with an air change rate of about 70 h-1, the addition of uv irradiation during surgery may achieve ultra clean air. However, in conventionally ventilated operating rooms uv-irradiation alone is probably not sufficient to do so

  13. Pressure sores following elective total hip arthroplasty: pitfalls of misinterpretation.

    Science.gov (United States)

    Keong, Nicole; Ricketts, David; Alakeson, Nuki; Rust, Philippa

    2004-01-01

    OBJECTIVE: To assess the reliability of reporting protocols regarding pressure sores. METHODS: Retrospective data were collected regarding pressure sore rates following total hip arthroplasty operations carried out during 2001 at two orthopaedic units in an NHS hospital (Princess Royal Hospital) and in a local private hospital. RESULTS: Preliminary results presented in audit and interim reports indicated an alarmingly high pressure sore rate across the two sites (17/172 [9.9%] NHS, 23/71 [32.4%] private hospital). On analysis, the data collection system was revealed to be flawed. Grade 1 areas (erythema with no ulceration) were included, leading to a dramatic discrepancy between reported and confirmed pressure sores. Re-analysis showed the confirmed pressure sore rates to be much lower (2.3% NHS, 1.0% private hospital). CONCLUSIONS: This audit suggests that both poor data collection and education lead to inaccurate audit. This may lead to subsequent inappropriate management and inappropriate NHS star ratings. PMID:15140301

  14. Periprosthetic femoral fracture within two years after total hip replacement:

    DEFF Research Database (Denmark)

    Thien, T. M.; Chatziagorou, G.; Garellick, G.

    2014-01-01

    BACKGROUND: We used the Nordic Arthroplasty Register Association database to evaluate whether age, sex, preoperative diagnosis, fixation, and implant design influence the risk of revision arthroplasty due to periprosthetic fracture within two years from operation of a primary total hip replacement....... METHODS: Included in the study were 325,730 cemented femoral stems and 111,899 uncemented femoral stems inserted from 1995 to 2009. Seven frequently used stems (two cemented stems [Exeter and Lubinus SP II] and five uncemented stems [Bi-Metric, Corail, CLS Spotorno, ABG I, and ABG II]) were specifically...... studied. RESULTS: The incidence of revision at two years was low: 0.47% for uncemented stems and 0.07% for cemented stems. Uncemented stems were much more likely to have this complication (relative risk, 8.72 [95% confidence interval, 7.37 to 10.32]; p

  15. MR imaging of 22 Charnley-Mueller total hip prostheses

    International Nuclear Information System (INIS)

    Lemmens, J.A.M.; Ruijs, J.H.J.

    1986-01-01

    To find out whether MR imaging is contraindicated in patients with metallic implants or can be a routine diagnostic procedure, MR investigations in 18 patients with 22 Charnley-Mueller total hip prostheses were performed on a 0.5 T Gyroscan S 5, Philips. No adverse reactions during or post MR investigation were encountered. The imaging of the soft tissue was superior to CT and showed less distortion. The diagnosis of loosening, by detection of demarcation lines at the interfaces was at its best in the distal part of the femoral stem prosthesis and was poor in the acetabular component and in the upper part of the stem prosthesis due to artifacts. (orig.) [de

  16. Hydrotherapy after total hip arthroplasty: a follow-up study.

    Science.gov (United States)

    Giaquinto, S; Ciotola, E; Dall'armi, V; Margutti, F

    2010-01-01

    The aim of the study was to evaluate the subjective functional outcome of total hip arthroplasty (THA) in patients who underwent hydrotherapy (HT) 6 months after discharge. A prospective randomized study was performed on 70 elderly inpatients with recent THA, who completed a rehabilitation program. After randomization, 33 of them were treated in conventional gyms (no-hydrotherapy group=NHTG) and 31 received HT (hydrotherapy group=HTG). Interviews with the Western-Ontario MacMasters Universities Osteoarthritis Index (WOMAC) were performed at admission, at discharge and 6 months later. Kruskal-Wallis, Mann-Whitney and Wilcoxon tests were applied for statistical analysis. Both groups improved. Pain, stiffness and function were all positively affected. Statistical analysis indicated that WOMAC sub-scales were significantly lower for all patients treated with HT. The benefits at discharge still remained after 6 months. We conclude that HT is recommended after THA in a geriatric population.

  17. Wear of alumina on alumina total hip prosthesis - effect of lubricant on hip simulator test

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, M.; Amino, H. [Kyocera Corp., Fushimi, Kyoto (Japan). Bioceram Div.; Oonishi, H. [Dept. of Orthopaedic Surgery, Artificial Joint Sect. and Biomat. Res. Lab., Osaka Minami National Hospital, Osaka (Japan); Clarke, I.C.; Good, V. [Dept. of Orthopaedic Surgery, Loma Linda Univ. Medical Center, CA (United States)

    2001-07-01

    The complex wear-friction-lubrication behavior of alumina on alumina combination in total hip prostheses (THP) was investigated using a hip joint simulator. The objectives of this study were to evaluate the effect of the ball/cup clearance and of the lubricant conditions. Alumina bearings were categorized in three diametrical clearances, 20-30, 60-70 and 90-100 micrometer, three each and wear tests were carried out with 90% bovine serum. There was no significant difference between three groups. Volumetric wear in the run-in phase for all tested nine ceramic liners averaged 0.27mm{sup 3}/million cycles and in the steady-state phase averaged 0.0042mm{sup 3}/million cycles. In addition to the 90% serum, 27% serum and saline were used as the lubricant for evaluate the effect of serum concentration on alumina on alumina wear couples. The wear test results showed that in all tested conditions the wear trends of alumina BEARING were bi-phasic and wear volume could be affected by the serum concentration. Both ''Run-in'' and ''Steady-state'' wear rates in 90% bovine serum were three times higher than those in saline. (orig.)

  18. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

    Science.gov (United States)

    2006-01-01

    The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large

  19. In vitro osteogenic capacity of bone marrow MSCs from postmenopausal women reflect the osseointegration of their cementless hip stems

    Directory of Open Access Journals (Sweden)

    Jessica J. Alm

    2016-12-01

    Full Text Available Age-related dysfunction of mesenchymal stromal cells (MSCs is suggested as a main cause of altered bone repair with aging. We recently showed that in postmenopausal women undergoing cementless total hip arthroplasty (THA aging, low bone mineral density (BMD and age-related geometric changes of the proximal femur are risk factors for increased early migration and delayed osseointegration of the femoral stems. Extending these analyses, we have here explored how the in vitro osteogenic capacity of bone marrow MSCs from these patients reflects implant osseointegration, representing the patient's in vivo bone healing capacity. A total of 19 postmenopausal women with primary hip osteoarthritis (mean age 65 years, range 50–78 and well-defined bone quality underwent successful preoperative in vitro analysis of osteogenic capacity of iliac crest bone marrow MSCs as well as two-year radiostereometric (RSA follow-up of femoral stem migration after cementless THA. In patients with MSCs of low osteogenic capacity, the magnitude of cumulative stem subsidence after the settling period of three months was greater (p = 0.028 and the time point for translational osseointegration was significantly delayed (p = 0.030 compared to patients with MSCs of high osteogenic capacity. This study suggests that patients with MSCs of low in vitro osteogenic capacity may display increased stem subsidence after the settling period of 3 months and thereby delayed osseointegration. Our study presents a novel approach for studying the biological progress of hip implant osseointegration and to verify the impact of decreased MSCs function, especially in patients with age-related dysfunction of MSCs and bone healing capacity. Keywords: Human mesenchymal stromal cells, Osteogenic differentiation, Radiostereometric analysis, Total hip arthroplasty, Osseointegration

  20. Acetabular QCT in Total Hip Arthroplasty - a reliability study using porcine hips

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    and reliability of bone mineral density measurements (BMD) in close proximity of the acetabular cup using SECT and DECT images and 3D segmentation software. Materials and methods 22 acetabular cups (12 cemented, 10 un-cemented) were inserted in porcine hip specimens ex vivo. A femoral stem was attached to each...... difference between the double measurements in SECT was 8 mg/cm3 (p=0.64) and 2 mg/cm3 in DECT (p=0.6). In the cemented concept the differences were 33 mg/cm3 (p=0.054) and 11 mg/cm3 (p=0.014), respectively. ICC was >0.90 regardless of scan mode and cup type. In both cup types the Bland-Altman limits...... of agreement were wider in SECT (uncemented: -95 to 111; cemented: -86 to 153) compared with DECT (uncemented: -28 to 23; cemented: -21 to 44). Conclusion There were no statistically significant reliability differences between SECT and DECT, but results suggest that the agreement of DECT is better than...

  1. Single- and dual energy QCT around acetabular cups in total hip arthroplasty using 3-dimensional segmentation

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Andersen, Poul Erik; Torfing, Trine

    of segmentation software and to compare bone mineral density (BMD) measurements in single- and dual energy CT (SECT and DECT) Materials and Methods: 24 male patients with total hip arthroplasty (12 cemented and 12 uncemented) were scanned and rescanned using SECT and virtual monochromatic DECT images. 3D- ROIs......Background: Bone density measurements around hip implants are challenged by artifacts and the complex anatomy of the acetabulum. We developed 3D segmentation software and used dual energy CT to reduce artifacts. Purpose / Aim of Study: To test the between-scan agreement and reliability...... the cemented cup the mean BMD for SECT was 523 mg/ccm with a between-scan difference of 14 mg/ccm, p=0.25 and 186 mg/ccm in DECT with a difference of 6 mg/ccm, p=0.15. ICC was >0.95 with more narrow limits of agreement in DECT compared with SECT. Computed tomography dose index (CTDI) was 25% higher with DECT...

  2. A multi-modality tracking, navigation and calibration for a flexible robotic drill system for total hip arthroplasty.

    Science.gov (United States)

    Ahmad Fuad, Ahmad Nazmi Bin; Deep, Kamal; Yao, Wei

    2018-02-01

    This paper presents a novel multi-modality tracking and navigation system that provides a unique capability to guild a flexible drill tip inside the bone with accurate curved tunnelling. As the flexible drill tip cannot be tracked optically inside the bone, this research focuses on developing a hybrid tracking and navigation system for tracking a flexible drill tip by using both optical and kinematic tracking. The tracking information is used to guide the THA (total hip arthroplasty) procedure, providing a real-time virtual model of the flexible drill. The flexible and steerable drill tip system is then tested on total hip arthroplasty followed by evaluation of the positioning and orientation of femoral stem placement by femoral milling. Based on this study, we conclude that the tracking and navigation system is able to guide the flexible drill to mill inside femoral canal. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Bone Marrow Stem Cells Added to a Hydroxyapatite Scaffold Result in Better Outcomes after Surgical Treatment of Intertrochanteric Hip Fractures

    Directory of Open Access Journals (Sweden)

    Joao Torres

    2014-01-01

    Full Text Available Introduction. Intertrochanteric hip fractures occur in the proximal femur. They are very common in the elderly and are responsible for high rates of morbidity and mortality. The authors hypothesized that adding an autologous bone marrow stem cells concentrate (ABMC to a hydroxyapatite scaffold and placing it in the fracture site would improve the outcome after surgical fixation of intertrochanteric hip fractures. Material and Methods. 30 patients were randomly selected and divided into 2 groups of 15 patients, to receive either the scaffold enriched with the ABMC (Group A during the surgical procedure, or fracture fixation alone (Group B. Results. There was a statistically significant difference in favor of group A at days 30, 60, and 90 for Harris Hip Scores (HHS, at days 30 and 60 for VAS pain scales, for bedridden period and time taken to start partial and total weight bearing (P<0.05. Discussion. These results show a significant benefit of adding a bone marrow enriched scaffold to surgical fixation in intertrochanteric hip fractures, which can significantly reduce the associated morbidity and mortality rates. Conclusion. Bone marrow stem cells added to a hydroxyapatite scaffold result in better outcomes after surgical treatment of intertrochanteric hip fractures.

  4. Bone Marrow Stem Cells Added to a Hydroxyapatite Scaffold Result in Better Outcomes after Surgical Treatment of Intertrochanteric Hip Fractures

    Science.gov (United States)

    Gutierres, Manuel; Lopes, M. Ascenção; Santos, J. Domingos; Cabral, A. T.; Pinto, R.

    2014-01-01

    Introduction. Intertrochanteric hip fractures occur in the proximal femur. They are very common in the elderly and are responsible for high rates of morbidity and mortality. The authors hypothesized that adding an autologous bone marrow stem cells concentrate (ABMC) to a hydroxyapatite scaffold and placing it in the fracture site would improve the outcome after surgical fixation of intertrochanteric hip fractures. Material and Methods. 30 patients were randomly selected and divided into 2 groups of 15 patients, to receive either the scaffold enriched with the ABMC (Group A) during the surgical procedure, or fracture fixation alone (Group B). Results. There was a statistically significant difference in favor of group A at days 30, 60, and 90 for Harris Hip Scores (HHS), at days 30 and 60 for VAS pain scales, for bedridden period and time taken to start partial and total weight bearing (P < 0.05). Discussion. These results show a significant benefit of adding a bone marrow enriched scaffold to surgical fixation in intertrochanteric hip fractures, which can significantly reduce the associated morbidity and mortality rates. Conclusion. Bone marrow stem cells added to a hydroxyapatite scaffold result in better outcomes after surgical treatment of intertrochanteric hip fractures. PMID:24955356

  5. CCD and offset after Nanos short stem in total hip arthroplasty.

    Science.gov (United States)

    Ettinger, M; Ettinger, P; Ezechieli, M; Büermann, S; Budde, S; Calließ, T; Petri, M; Thorey, F

    2013-01-01

    Many short stems for total hip arthroplasty have been introduced by the manufacturers only during the last decade. One of them is the Nanos short stem (Smith and Nephew, Marl, Germany). The development of short stems was aimed at preserving bone and soft tissue by utilizing a minimally invasive approach, thus allowing a quick return to an active life. It was purpose of this study to evaluate the radiological changes after using this device. We present the radiological results of 202 cementless THAs which were performed in 172 patients using the Nanos stem. Radiological evaluation was performed using standing anterior-posterior (AP) and lateral radiographs of the proximal femur preoperatively, postoperatively and during the follow up. We analyzed the preoperative and postoperativ CCD angle, the subsisdence, preoperative and postoperative offset, osteolysis, bone resorption, increased density, neocortex and periarthricular ossifications. One stem had to be revised due to subsidence four days after implantation. Two cups (BiconPlus, Smith and Nephew, Marl, Germany) had to be revised during the time of follow up due to an aseptic cup loosening. Two stems showed radiolucent lines at the implant-bone-interface at the last follow-up. An increase of bone density could be detected in 18 hips (8.9%). 14 hips showed periarticular ossifications. Measurable subsidence was detected in a total of four stems (1.9%). The preoperative neck-shaft-angle angle was 133.8 ± 4.4° (range: 118.5-146.2) and the neck-shaft-angle angle at the time of follow up was 134.6 ± 4.3° (range: 123.3-147; P< 0.05). The preoperative and postoperative offset changed from 109.3 ± 11.9 mm (range: 80.9-131.6) to 109.7 ± 12.3 mm (range: 79.7-155.6; P< 0.05). In summary, this study shows that a correct anatomical reconstruction is possible with a device of this design. The outcome is comparable to that of other short stems. Further studies should be performed in a prospective and randomized design to

  6. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    Science.gov (United States)

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  7. Functioning Before and After Total Hip or Knee Arthroplasty

    NARCIS (Netherlands)

    I.B. de Groot (Ingrid)

    2009-01-01

    textabstractOsteoarthritis (OA) of the hip or knee is a common locomotor disease characterized by degradation of articular cartilage. In the Netherlands, in the year 2000 about 257,400 persons above the age of 55 years had hip OA and about 335,700 persons had knee OA. Because the prevalence of OA

  8. Risk of contralateral avascular necrosis (AVN) after total hip arthroplasty (THA) for non-traumatic AVN.

    Science.gov (United States)

    Goker, Berna; Block, Joel A

    2006-01-01

    The risk of developing bilateral disease progressing to total hip arthroplasty (THA) among patients who undergo unilateral THA for non-traumatic avascular necrosis (AVN) remains poorly understood. An analysis of the time-course to contralateral THA, as well as the effects of underlying AVN risk factors, is presented. Forty-seven consecutive patients who underwent THA for AVN were evaluated. Peri-operative and annual post-operative antero-posterior pelvis radiographs were examined for evidence of contralateral involvement. Patient age, weight, height, underlying AVN risk factor(s), date of onset of contralateral hip pain if occurred, and date of contralateral THA if performed, were recorded. Bone scan, computerized tomography and magnetic resonance imaging data were utilized when available. Twenty-one patients (46.6%) underwent contralateral THA for AVN within a median of 9 months after the initial THA (range 0-93, interquartile range 28.5 months). The median follow-up for patients without contralateral THA was 75 months (range 3-109, interquartile range 69 months). Thirty-four patients had radiographic findings of contralateral AVN at study entry; 25 were symptomatic bilaterally at entry and 7 developed contralateral symptoms within a mean time of 12 months (median 10 months, interquartile range 12 months). None of the 13 patients who were free of radiographic evidence of contralateral AVN at study entry developed evidence of AVN during the follow-up. AVN associated with glucocorticoid use was more likely to manifest as bilateral disease than either idiopathic AVN or ethanol-associated AVN (P=0.02 and P=0.03 respectively). Radiographically-evident AVN in the contralateral hip at THA is unlikely to remain asymptomatic for a prolonged period of time. Conversely, asymptomatic contralateral hips without radiographic evidence of AVN are unlikely to develop clinically significant AVN.

  9. Blood Conservation Strategies in Total Hip and Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    David Liu

    2015-01-01

    Full Text Available Peri-operative blood management is one of a number of components important for successful patient care in total joint arthroplasty and surgeons should be proactive in its application. The aims of blood conservation are to reduce the risks of blood transfusion whilst at the same time maximizing haemaglobin in the post-operative period, thereby leading to a positive effect on early and long term outcomes and costs. An individualized strategy based on patient specific risk factors, anticipated blood loss and co-morbidities is useful in achieving this aim. Multiple blood conservation strategies are available in the pre-operative, intra-operative and post-operative periods and can be utilised either individually or in combination. Recent literature has highlighted the importance of identifying and correcting pre-operative anaemia, salvaging peri-operative red cells and the use of tranexamic acid in reducing blood loss. Given total hip and knee arthroplasty is an elective procedure, a zero allogenic blood transfusion rate should be the aim and an achievable goal.

  10. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-02

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  11. Immediate mobilisation with complete weight bearing after uncemented total hip replacement in elderly

    Directory of Open Access Journals (Sweden)

    Sankarlingam P, Shivraj V, V R Subramaniyam

    2014-11-01

    Full Text Available This prospective study was analyzed in 23 patients who were allowed to do immediate weight bearing after uncemented total hip arthroplasty. Immediate mobilization shortened the hospital stay and facilitated early rehabilitation of hip. Immediate mobilization was started on postoperative Day 3 rather than Day 7 without any adverse consequences to the patients. A series of 23 elderly patients of age more than 60 years, who were diagnosed with conditions such as avascular necrosis of hip, non union of fracture neck of femur, trochanteric non union and rheumatoid arthritis, underwent uncemented total hip replacement and immediate mobilization was started in our hospital. Patients were evaluated by Harris Hip Scoring Scale. All ambulated patients had painless hip and the mean Harris Hip Score was 85. There were no incidence of stem subsidence, acetabular component loosening, and heterotrophic ossification. This data concluded that early intensive rehabilitation yielded faster attainment of short-term functional milestones in fewer days.

  12. Bilateral simultaneous total hip arthroplasty in a fast track setting

    DEFF Research Database (Denmark)

    Otte, Kristian S; Husted, Henrik; Ørsnes, Thue

    2011-01-01

    and low complication rates when performed in a fast-track setting. We believed it would be useful to assess hip arthroplasty in this context, and we report 50 consecutive fast-track simultaneous bilateral hip arthroplasty procedures. The median length of stay was 4 days. Mortality within 90 days was 4......% and 8% required a further operative procedure. The overall complication rate was 22%. 55% of the complications were considered to be caused by failures in surgical technique and 45% by other factors. Bilateral simultaneous hip arthroplasty may have a high complication rate in a fast-track setting...

  13. Dislocation of total hip replacement in patients with fractures of the femoral neck

    OpenAIRE

    Enocson, Anders; Hedbeck, Carl-Johan; Tidermark, Jan; Pettersson, Hans; Ponzer, Sari; Lapidus, Lasse J

    2009-01-01

    Background Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach. Patients and methods We included 713 consecutive hips in a series of 698 p...

  14. Case Study of a physiotherapy treatment of a patient after total hip replacement

    OpenAIRE

    Havlíčková, Barbora

    2013-01-01

    The bachelor's thesis consists of two parts. The general part includes anatomy and kinesiology of the hip joint and also the topic of coxarthrosis as the most common reason for the total hip replacement surgery. An integral part of this part is the elaboration of a rehabilitation plan for patients undergoing such procedure. The practical part of the thesis is conceived a case study of a patient after total hip replacement because of coxarthrosis. Finally, the thesis includes the therapeutic o...

  15. Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2013-01-01

    Full Text Available Management of recurrent dislocation of total hip arthroplasty is often a challenging and daunting task. Re-revision of such a total hip prosthesis may not be easy as the removal of a well-fixed, fully coated stem is extremely difficult. We managed to salvage instability in three revision hip cases in which the fully coated stem had subsided by using a bioball universal neck adapter without changing the femoral stem or acetabular cup.

  16. [Three-dimensional finite element analysis on mechanical behavior of the bone remodeling and bone integration between the bone-implant interface after hip replacement].

    Science.gov (United States)

    Li, Yong-Jiang; Zhang, Li-Cheng; Zhang, Mei-Chao; Yang, Guo-Jing; Lin, Rui-Xin; Cai, Chun-Yuan; Zhong, Shi-Zhen

    2014-04-01

    To discuss the primary stability of the fixed interface between the cementless prosthesis and femur, and its influence on bone ingrowth and secondary stability under the roughened surface and press fit of different prostheses by finite element analysis. :A three-dimensional finite element module of total hip arthroplasty (THA) was developed with Mimics software. There was a collection of data when simulating hip arthroplasty. The frictional coefficient between the fixed interface was 0,0.15,0.40 and 1.00 representing the roughness of prosthesis surface. The press fit was 0, 0.01,0.05 and 0.10 mm according to the operation. The Vion Mises stress distribution and the contact pressure,friction stress and relative sliding displacement between the interface were analysed and compared when simulating the maneuver of climbing stairs. At a fixed press fit of 0.05 mm,the contact pressure between the interface was 230 , 231, 222 and 275 MN under four different frictional coefficient (0,0. 15,0.40 and 1.00) with little change; the relative sliding displacement was 0.529, 0.129, 0.107 and 0.087 mm with a consistent and obvious decline. As the fixed frictional coefficient was 0.40,the contact pressure between the interface were 56.0,67.7 ,60.4 and 49.6 MN under four different press fit (0, 0.01, 0.05 and 0.10 mm) with a reduction; the relative sliding displacement was 0.064,0.062,0.043 and 0.042 mm with an obvious decline, and there was a maximal friction stress when press fit of 0.01 mm. There is a dynamic process of the bone remodeling and bone integration between the interface after hip replacement, determining the long-term outcome. The interface clearance and the frictional coefficient are the key factors of the bone integration.

  17. Characterization of Fatty Acid Composition in Bone Marrow Fluid From Postmenopausal Women: Modification After Hip Fracture.

    Science.gov (United States)

    Miranda, Melissa; Pino, Ana María; Fuenzalida, Karen; Rosen, Clifford J; Seitz, Germán; Rodríguez, J Pablo

    2016-10-01

    Bone marrow adipose tissue (BMAT) is associated with low bone mass, although the functional consequences for skeletal maintenance of increased BMAT are currently unclear. BMAT might have a role in systemic energy metabolism, and could be an energy source as well as an endocrine organ for neighboring bone cells, releasing cytokines, adipokines and free fatty acids into the bone marrow microenvironment. The aim of the present report was to compare the fatty acid composition in the bone marrow supernatant fluid (BMSF) and blood plasma of postmenopausal women women (65-80 years old). BMSF was obtained after spinning the aspirated bone marrow samples; donors were classified as control, osteopenic or osteoporotic after dual-energy X-ray absorptiometry. Total lipids from human bone marrow fluid and plasma were extracted, converted to the corresponding methyl esters, and finally analyzed by a gas chromatographer coupled with a mass spectrometer. Results showed that fatty acid composition in BMSF was dynamic and distinct from blood plasma, implying significance in the locally produced lipids. The fatty acid composition in the BMSF was enriched in saturated fatty acid and decreased in unsaturated fatty acids as compared to blood plasma, but this relationship switched in women who suffered a hip fracture. On the other hand, there was no relationship between BMSF and bone mineral density. In conclusion, lipid composition of BMSF is distinct from the circulatory compartment, most likely reflecting the energy needs of the marrow compartment. J. Cell. Biochem. 117: 2370-2376, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    Science.gov (United States)

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. [Ceramic-on-ceramic bearings in total hip arthroplasty (THA)].

    Science.gov (United States)

    Sentürk, U; Perka, C

    2015-04-01

    The main reason for total hip arthroplasty (THA) revision is the wear-related aseptic loosening. Younger and active patients after total joint replacement create high demands, in particular, on the bearings. The progress, especially for alumina ceramic-on-ceramic bearings and mixed ceramics have solved many problems of the past and lead to good in vitro results. Modern ceramics (alumina or mixed ceramics containing alumina) are extremely hard, scratch-resistant, biocompatible, offer a low coefficient of friction, superior lubrication and have the lowest wear rates in comparison to all other bearings in THA. The disadvantage of ceramic is the risk of material failure, i.e., of ceramic fracture. The new generation of mixed ceramics (delta ceramic), has reduced the risk of head fractures to 0.03-0.05 %, but the risk for liner fractures remains unchanged at about 0.02 %. Assuming a non-impinging component implantation, ceramic-on-ceramic bearings have substantial advantages over all other bearings in THA. Due to the superior hardness, ceramic bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process. A specific complication for ceramic-on-ceramic bearings is "squeaking". The high rate of reported squeaking (0.45 to 10.7 %) highlights the importance of precise implant positioning and the stem and patient selection. With precise implant positioning this problem is rare with many implant designs and without clinical relevance. The improved tribology and the presumable resulting implant longevity make ceramic-on-ceramic the bearing of choice for young and active patients. Georg Thieme Verlag KG Stuttgart · New York.

  20. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    Science.gov (United States)

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  1. MRI screening on bone ischemia of hip and knee in recovered SARS patients

    International Nuclear Information System (INIS)

    Cheng Xiaoguang; Qu Hui; Liu Wei; Sun Jing; Cheng Kebin; Feng Suchen; Li Xiaosong

    2004-01-01

    Objective: To screen ischemia in the hip and knee joints of recovered SARS patients with MRI, and to investigate the prevalence rate of bone ischemia in those patients and its relationship with the use of steroid. Methods: Hip and knee MRI examinations were performed in 76 recovered SARS patients. There were 17 males and 59 females. Eight patients were treated without steroid, while 68 patients with steroid. Dose and duration of steroid usage were available in 30 out of 68 patients. The MRI images were read by senior radiologists to determine whether bone ischemia and/or osteonecrosis was present. Appropriate statistic analysis was performed to determine the significance of difference between groups. Results: (1) The MRI appearance of osteonecrosis in femoral head and condyle and bone infarct in bone marrow found in SARS patients was identical to those caused by other conditions (including steroid usage in other diseases). (2) No one of 8 SARS without steroid developed osteonecrosis, while 25 out of 68 steroid users had osteonecrosis found by MRI screening, and the difference in prevalence of osteonecrosis between these 2 groups was significant. In 25 patients with osteonecrosis, 20 of them involved more than one joints. Osteonecrosis involved 32 femoral heads, 26 femoral condyles, and 6 in femoral and tibial shafts. Thirteen patients with osteonecrosis had greater total steroid dose, greater daily dose, and longer duration than those (17 patients) without osteonecrosis, however, the differences between the two groups were not statistically significant. Sixty-four patients out of 76 complained pain in joints, 50 of them had multiple joint pains. The pain was reported in hips in 40 cases, followed by knees in 36, low backs in 10, shoulders in 7, and wrists in 4, respectively. The differences in frequency of pain between steroid users and non-steroid users, as well as between osteonecrosis and non-osteonecrosis were not significant. Conclusion: MRI is recommended for

  2. High Re-Operation Rates Using Conserve Metal-On-Metal Total Hip Articulations

    DEFF Research Database (Denmark)

    Mogensen, S L; Jakobsen, Thomas; Christoffersen, Hardy

    2016-01-01

    INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two-center st......INTRODUCTION: Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two...

  3. Clinical outcomes in relation to locations of bone marrow edema lesions in patients with a subchondral insufficiency fracture of the hip: a review of fifteen cases.

    Science.gov (United States)

    Ikemura, Satoshi; Mawatari, Taro; Matsui, Gen; Iguchi, Takahiro; Mitsuyasu, Hiroaki

    2016-10-01

    The prognosis of patients with a subchondral insufficiency fracture remains unclear. The purpose of this study was to investigate the correlation between locations of bone marrow edema (BME) lesions and clinical outcome in patients with a subchondral insufficiency fracture of the hip. We retrospectively reviewed 15 consecutive hips in 14 patients who were diagnosed with subchondral insufficiency fracture of the hip at our institution between April 2013 and September 2014. This study included five males (six hips) and nine females (nine hips), ranging from 36 to 83 years of age (mean age: 66 years). The mean duration from the onset of hip pain to MRI examination was 1.8 months (range 0.5-5 months). Both clinical and imaging findings were investigated. Based on the findings of MR images, BME lesion in the femoral head alone was observed in six patients (six hips), BME lesion in the acetabulum alone was observed in one patient (two hips) and BME lesions in both the femoral head and acetabulum were observed in seven patients (seven hips). 3 of 15 hips resulted in rapidly destructive arthrosis and their BME lesions were observed in both the femoral head and acetabulum. 8 of 15 hips successfully healed by conservative treatment and BME lesions in 7 of these 8 hips were observed in only the femoral head or acetabulum. The results of this study indicate that the locations of BME lesions (femoral side alone, acetabular side alone or both) may be related to the clinical outcome in patients with a subchondral insufficiency fracture of the hip. Patients with subchondral insufficiency fracture of the hip in whom BME lesions were observed in both the femoral head and acetabulum may have a higher risk to need to undergo total hip arthroplasty.

  4. The Consumer Quality Index Hip Knee Questionnaire measuring patients' experience with quality of care after a total hip or knee arthroplasty.

    NARCIS (Netherlands)

    Stubbe, J.H.; Gelsema, T.; Delnoij, D.M.J.

    2007-01-01

    Background: The Dutch Consumer Quality Index Hip Knee Questionnaire (CQI Hip Knee) was used to assess patients' experiences with and evaluations of quality of care after a total hip (THA) or total knee arthroplasty (TKA). The aim of this study is to evaluate the construct validity and internal

  5. Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know

    Energy Technology Data Exchange (ETDEWEB)

    Huppertz, Alexander [Charite - University Hospitals Berlin, Department of Radiology, Berlin (Germany); Imaging Science Institute Charite, Berlin (Germany); Radmer, Sebastian [Proendo, Orthopedic Surgery, Berlin (Germany); Wagner, Moritz; Hamm, Bernd [Charite - University Hospitals Berlin, Department of Radiology, Berlin (Germany); Roessler, Torsten [Klinikum Ernst von Bergmann, Department of Trauma and Orthopedic Surgery, Potsdam (Germany); Sparmann, Martin [Proendo, Orthopedic Surgery, Berlin (Germany); Charite - University Hospital, Berlin (Germany)

    2014-08-15

    The number of total hip arthroplasties is continuously rising. Although less invasive surgical techniques, sophisticated component design, and intraoperative navigation techniques have been introduced, the rate of peri- and postoperative complications, including dislocations, fractures, nerve palsies, and infections, is still a major clinical problem. Better patient outcome, faster recovery and rehabilitation, and shorter operation times therefore remain to be accomplished. A promising strategy is to use minimally invasive techniques in conjunction with modular implants, aimed at independently reconstructing femoral offset and leg length on the basis of highly accurate preoperative planning. Plain radiographs have clear limitations for the correct estimation of hip joint geometry and bone quality. Three-dimensional assessment based on computed tomography (CT) allows optimizing the choice and positions of implants and anticipating difficulties to be encountered during surgery. Postoperative CT is used to monitor operative translation and plays a role in arthroplastic quality management. Radiologists should be familiar with the needs of orthopedic surgeons in terms of CT acquisition, post-processing, and data transfer. The CT protocol should be optimized to enhance image quality and reduce radiation exposure. When dedicated orthopedic CT protocols and state-of-the-art scanner hardware are used, radiation exposure can be decreased to a level just marginally higher than that of conventional preoperative radiography. Surgeons and radiologists should use similar terminology to avoid misunderstanding and inaccuracies in the transfer of preoperative planning. (orig.)

  6. Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings

    Directory of Open Access Journals (Sweden)

    Tatsuya Tamaki

    2017-01-01

    Full Text Available The natural course of adverse events following the use of metal-on-metal (MoM bearings in total hip arthroplasty (THA is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.

  7. Reverse-total shoulder arthroplasty cost-effectiveness: A quality-adjusted life years comparison with total hip arthroplasty.

    Science.gov (United States)

    Bachman, Daniel; Nyland, John; Krupp, Ryan

    2016-02-18

    To compare reverse-total shoulder arthroplasty (RSA) cost-effectiveness with total hip arthroplasty cost-effectiveness. This study used a stochastic model and decision-making algorithm to compare the cost-effectiveness of RSA and total hip arthroplasty. Fifteen patients underwent pre-operative, and 3, 6, and 12 mo post-operative clinical examinations and Short Form-36 Health Survey completion. Short form-36 Health Survey subscale scores were converted to EuroQual Group Five Dimension Health Outcome scores and compared with historical data from age-matched patients who had undergone total hip arthroplasty. Quality-adjusted life year (QALY) improvements based on life expectancies were calculated. The cost/QALY was $3900 for total hip arthroplasty and $11100 for RSA. After adjusting the model to only include shoulder-specific physical function subscale items, the RSA QALY improved to 2.8 years, and its cost/QALY decreased to $8100. Based on industry accepted standards, cost/QALY estimates supported both RSA and total hip arthroplasty cost-effectiveness. Although total hip arthroplasty remains the quality of life improvement "gold standard" among arthroplasty procedures, cost/QALY estimates identified in this study support the growing use of RSA to improve patient quality of life.

  8. Psychopharmacologic treatment and blood transfusion in fast-track total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Gylvin, Silas Hinsch; Jørgensen, Christoffer Calov; Fink-Jensen, Anders

    2017-01-01

    BACKGROUND: Selective serotonin reuptake inhibitors (SSRIs) and other psychotropics are receiving increasing attention due to reports on inhibition of thrombocyte function and an increased bleeding risk in surgical settings. Studies in total hip and total knee arthroplasty (THA and TKA...

  9. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  10. Revision Total Hip Arthoplasty: Factors Associated with Re-Revision Surgery

    OpenAIRE

    Khatod, M; Cafri, G; Inacio, MCS; Schepps, AL; Paxton, EW; Bini, SA

    2015-01-01

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty.A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revi...

  11. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  12. Radiographic and tomographic evaluation of total hybrid hip replacement in dogs; Avaliacao radiografica e tomografica de caes submetidosa artroplastia coxofemoral total hibrida

    Energy Technology Data Exchange (ETDEWEB)

    Minto, B.W., E-mail: brunowminto@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Jaboticabal, SP (Brazil); Brandao, C.V.S.; Pereira, G.J.C.; Babicsak, V.R.; Vulcano, L.C.; Rossetto, V.J.V. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2016-11-15

    The total hip arthroplasty is the most effective surgical technique for the treatment of severe canine hip dysplasia. Currently, the radiographic examination is the most common method used to assess this procedure in dogs, but has some limitations. CT scan by computed tomography instead enables the acquisition of images without overlap, thereby determining the positioning of prosthetic components with greater accuracy. This research aimed to evaluate by radiography and CT scan examinations the use of a hybrid modular total hip prosthesis developed and made in Brazil, applied experimentally in healthy dogs. Six skeletally mature dogs, which previously underwent surgery on the left hip joint were used. The dogs underwent CT scan at 360 days and three years after surgery. All animals showed good positioning of prosthetic components, and proper joint reduction. In the CT scan, however, it was possible to detect irregular fill areas in some animals. In addition, CT scan allowed the detection and monitoring of areas of bone resorption around the acetabular component. Therefore, the CT scan was useful in the evaluation of prosthetic joints, with the advantage of optimum sharpness of the images and allowing for the possibility of quantifying peri-prosthetic changes and measure joint, fundamental relations for late postoperative follow-up. (author)

  13. Actis Total Hip System 2 Year Follow-up

    Science.gov (United States)

    2017-08-14

    Osteoarthritis; Traumatic Arthritis; Rheumatoid Arthritis; Congenital Hip Dysplasia; Avascular Necrosis of the Femoral Head; Acute Traumatic Fracture of the Femoral Head or Neck; Certain Cases of Ankylosis; Non-union of Femoral Neck Fractures; Certain High Sub-Capital & Femoral Neck Fractures in Elderly

  14. A new digital preoperative planning method for total hip arthroplasties

    NARCIS (Netherlands)

    Crooijmans, H.J.A.; Laumen, A.M.R.P.; van Pul, C.; van Mourik, J.B.A.

    Preoperative templating is an important part of a THA. The ability to accurately determine magnification of the hip on the radiograph and apply identical magnification to the radiograph and template will improve accuracy of preoperative templating of THA. We designed a templating method using a new

  15. Alternative outcome measures in young total hip arthroplasty patients

    DEFF Research Database (Denmark)

    Klit, Jakob; Jacobsen, Steffen; Schmiegelow, Victoria

    2015-01-01

    -life. Questionnaires including Oxford Hip Score (OHS) and SF-36 were evaluated preoperatively and 3, 6 and 12 months postoperatively. OHS and SF-36 showed significant improvements (pWilcoxon Signed Rank test). THA did not affect the patients' socioeconomic status. Increased frequency of intercourse or better...

  16. Treatment of primary hip osteoarthritis for the primary care physician and the indications for total hip arthroplasty.

    Science.gov (United States)

    Levine, Mathew E; Nace, James; Kapadia, Bhaveen H; Issa, Kimona; Banerjee, Samik; Cherian, Jeffery J; Mont, Michael A

    2013-01-01

    Osteoarthritis is a degenerative condition that commonly affects knees and hips with an annual incidence of 88 in 100,000 people in the United States. The purpose of this study was to review the clinical presentation of osteoarthritis of the hip as well as the available management options. We reviewed the recent literature in regard to epidemiology, presentation, and treatment options available to patients. Nonoperative treatments include weight loss and low-impact, aerobic exercises. Along with weight loss and exercise, nonsteroidal anti-inflammatory drugs (NSAIDS), narcotics, and intra-articular steroid injections have been used to improve patient's symptoms. Surgical intervention is a viable option; however, indications such as severe pain that is refractory to nonsurgical management, osteophytes, or joint space narrowing on radiographic films, or impairment of function should be present. The most common surgical option, total hip arthroplasty, has been shown to improve a patient's physical and psychological well-being. However, inherent risks are present with surgery and these should be addressed with the patient so a sound decision can be made. Osteoarthritis of the hip can be bothersome to patients, but physicians can begin management with lifestyle changes or pharmaceuticals. In the event nonoperative measures fail to markedly improve quality of life, total hip arthroplasty remains a viable option.

  17. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    International Nuclear Information System (INIS)

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  18. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis

    DEFF Research Database (Denmark)

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik

    2016-01-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare......,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk...... of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients....

  19. Alternative materials to improve total hip replacement tribology.

    Science.gov (United States)

    Santavirta, Seppo; Böhler, Max; Harris, William H; Konttinen, Yrjö T; Lappalainen, Reijo; Muratoglu, Orhun; Rieker, Claude; Salzer, Martin

    2003-08-01

    An improvement in tribology of bearing surfaces is an effective means of increasing the longevity of total hip replacement (THR). Currently, 3 approaches are available to achieve this aim: first, use of highly cross-linked UHMWPE; second, aluminum oxide ceramic bearings, and third, metal-on-metal bearings. Cross-linking reduces the wear resistance of UHMWPE markedly without impairment of other significant properties of the material. Simulator studies and some clinical long-term (10-22 years) follow-up surveys suggest an almost immeasurable wear of the highly cross-linked UHMWPE-based acetabular components during an expected clinical life span. Bioinert alumina ceramic (aluminum oxide) was introduced 3 decades ago for THR-bearing surfaces to improve performance and longevity. Alumina ceramic is entirely biostable and bioinert and has good mechanical properties. For correctly positioned alumina-on-alumina bearings, the annual linear wear rate has been reported to be 3.9 microm. Alumina heads have been successfully used in combination with polyethylene sockets, but as regards wear, the best results have been obtained with alumina-on-alumina bearings. In ceramic THR bearings, precise manufacture and contact surface geometry, including optimal clearance, are most important. For the currently available products, the component fracture risk is almost nonexistent (less than 1 per 1000). Metal-on-metal bearings were used in the early stage of THR surgery, although not all old designs were successful. More recent analyses of the early series have shown the advantages of metal-on-metal to be better and have led to a renaissance of this articulation. Initially, stainless steel was used because it was easy to manufacture and polish. Current metal-on-metal bearings are based on cobalt-chromium-molybdenum alloys with varying carbon contents. Such bearings are self-polishing. Linear wear rates remain at the level of a few microm a year. An improvement in technology has increased

  20. A Report Of Two Cases Of Uncemented Total Hip Replacement In ...

    African Journals Online (AJOL)

    This is a report of two sickle cell patients (HbSS) with advanced osteoarthritis of the right hip. The patients were in Ficat and Arlet\\'s stage 3 and 4 respectively. Both were females aged 23 and 46 years and they had uncemented hydroxyapatite coated omnifit (Stryker Howmedica Osteonics) total hip prosthetic replacement.

  1. A randomised, controlled clinical study on total hip arthroplasty using 4 different bearings

    DEFF Research Database (Denmark)

    Borgwardt, Arne; Zerahn, Bo; Fabricius, Sandra D

    2017-01-01

    PURPOSE: To compare 4 different bearings in total hip arthroplasty (THA) in a randomised controlled clinical study on clinical performance. METHODS: 393 patients with osteoarthritis of the hip or avascular necrosis were included and allocated to 1 of the head-and-cup couples zirconia...

  2. One-year incidence of prosthetic joint infection in total hip arthroplasty

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, A B; Schønheyder, H C

    2017-01-01

    OBJECTIVE: To examine the trend of Prosthetic Joint Infections (PJI) following primary total hip arthroplasty (THA) and the antimicrobial resistance of the bacteria causing these infections. MATERIALS AND METHODS: We identified a population-based cohort of patients in the Danish Hip Arthroplasty...

  3. Consequence of reduced necrotic bone elastic modulus in a Perthes' hip

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Skytte, Tina Lercke; Mikkelsen, Lars Pilgaard

    Introduction Perthes is a destructive hip joint disorder characterized as a malformation of the femoral head which affects young children. Several studies have shown the change of mechanical properties of the femoral head in Perthes’ disease. However, the consequence of the changes in bone...... mechanical properties in a Perthes’ hip is not well established. Due to the material differences, changes in bone mechanical properties might lead to localization of stress and deformation. Thus, the objective of this study was to investigate the effects of reduced elastic modulus of necrotic bone...... weight) was applied on the top of the femoral head. The distal part of the femur was fixed. The same Poisson’s ratio 0.3 was set for the femoral and necrotic bone. The elastic modulus (E) of femoral bone was 500 MPa. To investigate the effects of reduced elastic modulus, the necrotic bone E was reduced...

  4. A longitudinal study of quality of life and functional status in total hip and total knee replacement patients.

    Science.gov (United States)

    Mandzuk, Lynda L; McMillan, Diana E; Bohm, Eric R

    2015-05-01

    Primary total hip and primary total knee surgeries are commonly performed to improve patients' quality of life and functional status. This longitudinal retrospective study (N = 851) examined self-reported quality of life and functional status over the preoperative and postoperative periods: 12 months prior to surgery, one month prior to surgery and 12 months following surgery. A linear mixed effects model was used to analyze the changes in quality of life and functional status over the sampling period. Patients in the convenience sample reported improvements in quality of life and functional status utilizing the SF-12 and Oxford Hip and Oxford Knee, although differences were noted by procedure and gender. Total hip patients tended to demonstrate greater improvement than total knee patients and males reported higher levels of physical and mental quality of life as well as functional status when compared to females. Of particular note was that mental health scores were consistently lower in both total hip and total knee replacement patients across the perioperative period and up to one year postoperative. This study identifies an opportunity for health care providers to proactively address the mental health of total hip and total knee replacement patients throughout their joint replacement trajectory. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Bone mineral density after implantation of a femoral neck hip prosthesis--a prospective 5 year follow-up.

    Science.gov (United States)

    Steens, Wolfram; Boettner, Friedrich; Bader, Rainer; Skripitz, Ralf; Schneeberger, Alberto

    2015-08-12

    Bone resorption in the proximal femur due to stress shielding has been observed in a number of conventional cementless implants used in total hip arthroplasty. Short femoral-neck implants are claiming less interference with the biomechanics of the proximal femur. The goal of this study was to prospectively investigate the in vivo changes of bone-mineral density as a parameter of bone remodeling around a short, femoral neck prosthesis over the first 5 years following implantation. The secondary goal was to report on its clinical outcome. We are reporting on the changes of bone mineral density of the proximal femur and the clinical outcome up to five years after implantation of a short femoral neck prosthesis. Bone mineral density was determined using dual energy x-ray absorptiometry, performed 10 days, three, 12 and 60 months after surgery. 20 patients with a mean age of 47 years (range 17 to 65) were clinically assessed using the Harris Hip Score. The WOMAC was used as a patient-relevant outcome-measure. In contrast to conventional implants DEXA-scans overall revealed a slight increase of bone mineral density in the proximal femur in the 12 months following the implantation. The Harris Hip Score improved from an average preoperative score of 46 to a postoperative score at 12 months of 91 points and 95 points at 60 months, the global WOMAC index from 5.3 preoperatively to 0.8 at 12 months and 0.6 at 60 months postoperatively. At 60 months after implantation of a short femoral neck prosthesis, all regions except one (region of interest #5) showed no significant changes in BMD compared to baseline measurements at 10 days which is less to the changes in bone mineral density seen in conventional implants.

  6. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  7. Hip disability and osteoarthritis outcome score (HOOS)--validity and responsiveness in total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, Anna K; Lohmander, L Stefan; Klässbo, Maria

    2003-01-01

    The aim of the study was to evaluate if physical functions usually associated with a younger population were of importance for an older population, and to construct an outcome measure for hip osteoarthritis with improved responsiveness compared to the Western Ontario McMaster osteoarthritis score...

  8. Total body irradiation in bone marrow transplantation

    International Nuclear Information System (INIS)

    Gluckman, E.; Devergie, A.; Boiron, M.; Bernard, Jean; Dutreix, A.; Dutreix, J.

    1979-01-01

    Total body irradiation was used in 22 patients as part of their conditioning regimen for bone marrow transplantation. Nine patients with acute leukemia received 1000 cGy TBI in addition with chemotherapy. None of them survived and the main cause of death was interstitial pneumonitis (50%). 4 patients received 1000 cGy with a lung shielding of 500 cGy. Two patients with acute leukemia died of leukemia and sepsis, two patients had aplastic anemia, one is surviving, the other died of severe GVHD and infectious complications. Nine patients with severe aplastic anemia strongly immunized by previous blood transfusions received 800 cGy TBI with a lung shielding of 400 cGy. No rejection was observed and 7 patients (63%) are currently alive. One patient died of interstitial pneumonitis probably related to CMV infection, one of subacute necrotizing hepatitis, two of severe acute GVHD. It is concluded from this study that TBI remains the best immunosuppressive conditioning regimen even in strongly immunized patients. It may be a contributing factor of the incidence and severity of interstitial pneumonitis. A reduction of the dose of the lung to 400-500 cGy seems to decrease the severity of this complication

  9. Plasma dimethylglycine, nicotine exposure and risk of low bone mineral density and hip fracture: the Hordaland Health Study.

    Science.gov (United States)

    Øyen, J; Svingen, G F T; Gjesdal, C G; Tell, G S; Ueland, P M; Lysne, V; Apalset, E M; Meyer, K; Vollset, S E; Nygård, O K

    2015-05-01

    In the large community-based Hordaland Health Study, low plasma dimethylglycine was associated with low bone mineral density in both middle-aged and elderly subjects and to an increased risk of subsequent hip fracture among the elderly. These associations seemed to be particularly strong among subjects exposed to nicotine. Dimethylglycine (DMG) is a product of the choline oxidation pathway and formed from betaine during the folate-independent remethylation of homocysteine (Hcy) to methionine. Elevated plasma DMG levels are associated with atherosclerotic cardiovascular disease and inflammation, which in turn are related to osteoporosis. High plasma total Hcy and low plasma choline are associated with low bone mineral density (BMD) and hip fractures, but the role of plasma DMG in bone health is unknown. We studied the associations of plasma DMG with BMD among 5315 participants (46-49 and 71-74 years old) and with hip fracture among 3310 participants (71-74 years old) enrolled in the Hordaland Health Study. In age and sex-adjusted logistic regression models, subjects in the lowest versus highest DMG tertile were more likely to have low BMD (odds ratio [OR] 1.68, 95% confidence interval [CI] 1.43-1.99). The association was stronger in participants exposed compared to those unexposed to nicotine (OR 2.31, 95% CI 1.73-3.07 and OR 1.43, 95% CI 1.16-1.75, respectively, p interaction = 0.008). In the older cohort, Cox regression analyses adjusted for sex showed that low plasma DMG was associated with an increased risk of hip fracture (hazard ratio [HR] 1.70, 95% CI 1.28-2.26). A trend toward an even higher risk was found among women exposed to nicotine (HR 3.41, 95% CI 1.40-8.28). Low plasma DMG was associated with low BMD and increased risk of hip fractures. A potential effect modification by nicotine exposure merits particular attention.

  10. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis.

    Science.gov (United States)

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-06-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994-2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results - We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients.

  11. Understanding Total Hip Replacement Recovery towards the Design of a Context-Aware Systems

    NARCIS (Netherlands)

    Jimenez Garcia, Juan

    2011-01-01

    Total Hip Replacement (THR) is a common procedure to improve the mobility of elderly with osteoarthritis. Presently information about the recovery process after discharge is unclear. As consequence patients and physiotherapists face uncertainties to follow an adequate trajectory for recovery.

  12. A Numerical Study of Effects of the Manufacture Perturbations to Contacts of the Total Hip Replacement

    Czech Academy of Sciences Publication Activity Database

    Koukal, M.; Fuis, Vladimír; Florian, Z.; Janíček, P.

    2011-01-01

    Roč. 18, č. 1 (2011), s. 33-42 ISSN 1802-1484 Institutional research plan: CEZ:AV0Z20760514 Keywords : total hip replacement * FEM * roundness * contact pressure * frictional moment Subject RIV: BO - Biophysics

  13. Is etoricoxib effective in preventing heterotopic ossification after primary total hip arthroplasty?

    NARCIS (Netherlands)

    Brunnekreef, J.J.; Hoogervorst, P.; Ploegmakers, M.J.M.; Rijnen, W.H.C.; Schreurs, B.W.

    2013-01-01

    PURPOSE: Heterotopic ossification is a common complication after total hip arthroplasty. Non-steroidal anti-inflammatory drugs (NSAIDs) are known to prevent heterotopic ossifications effectively, however gastrointestinal complaints are reported frequently. In this study, we investigated whether

  14. Can shared care deliver better outcomes for patients undergoing total hip replacement?

    NARCIS (Netherlands)

    Rosendal, H.; Beekum, W.T. van; Nijhof, P.; Witte, L.P. de; Schrijvers, A.J.P.

    2000-01-01

    Objectives: To assess whether shared care for patients undergoing total hip replacement delivers better outcomes compared to care as usual. Design: Prospective, observational cohort study. Setting: Two regions in the Netherlands where different organisational health care models have been

  15. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  16. Fractures of the greater trochanter following total hip replacement.

    Science.gov (United States)

    Brun, Ole-Christian L; Maansson, Lukas

    2013-01-01

    We studied the incidence of greater trochanteric fractures at our department following THR. In all we examined 911 patients retrospectively and found the occurance of a greater trochanteric fracture to be 3%. Patients with fractures had significantly poorer outcome on Oxford Hip score, Pain VAS, Satisfaction VAS and EQ-5D compared to THR without fractures. Greater trochanteric fracture following THR is one of the most common complications following THR. It has previously been thought to have little impact on the overall outcome following THR, but our study suggests otherwise.

  17. Pre-fracture individual characteristics associated with high total health care costs after hip fracture.

    Science.gov (United States)

    Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E

    2017-03-01

    Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.

  18. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    Energy Technology Data Exchange (ETDEWEB)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong (Second Hospital Affiliated to the Medical College of Xi' an Jiaotong Univ., Xi' an Shaanxi (China))

    2009-08-15

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8+-2.1 mm and 7.1+-3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  19. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    International Nuclear Information System (INIS)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong

    2009-01-01

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8±2.1 mm and 7.1±3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  20. Use of Hip Arthroscopy and Risk of Conversion to Total Hip Arthroplasty: A Population-Based Analysis.

    Science.gov (United States)

    Schairer, William W; Nwachukwu, Benedict U; McCormick, Frank; Lyman, Stephen; Mayman, David

    2016-04-01

    To use population-level data to (1) evaluate the conversion rate of total hip arthroplasty (THA) within 2 years of hip arthroscopy and (2) assess the influence of age, arthritis, and obesity on the rate of conversion to THA. We used the State Ambulatory Surgery Databases and State Inpatient Databases for California and Florida from 2005 through 2012, which contain 100% of patient visits. Hip arthroscopy patients were tracked for subsequent primary THA within 2 years. Out-of-state patients and patients with less than 2 years follow-up were excluded. Multivariate analysis identified risks for subsequent hip arthroplasty after arthroscopy. We identified 7,351 patients who underwent hip arthroscopy with 2 years follow-up. The mean age was 43.9 ± 13.7 years, and 58.8% were female patients. Overall, 11.7% of patients underwent THA conversion within 2 years. The conversion rate was lowest in patients aged younger than 40 years (3.0%) and highest in the 60- to 69-year-old group (35.0%) (P arthroscopy. Patients treated at high-volume hip arthroscopy centers had a lower THA conversion rate than those treated at low-volume centers (15.1% v 9.7%, P arthroscopy is performed in patients of various ages, including middle-aged and elderly patients. Older patients have a higher rate of conversion to THA, as do patients with osteoarthritis or obesity. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Assessment and management of chronic pain in patients with stable total hip arthroplasty

    OpenAIRE

    Classen, Tim; Zaps, Daniela; Landgraeber, Stefan; Li, Xinning; Jäger, Marcus

    2012-01-01

    Total hip arthroplasty (THA) is one of the most successful operations that can restore function and relieve pain. Although a majority of the patients achieve significant pain relief after THA, there are a number of patients that develop chronic pain for unknown reasons. A literature search was performed looking for chronic pain after total hip arthroplasty and stable THA. Major causes of chronic pain include aseptic loosening or infection. However, there is a subset of patients with a stable ...

  2. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    OpenAIRE

    Hirokazu Takai, MD; Tomoki Takahashi, MD, PhD

    2017-01-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used ...

  3. Preoperative radiotherapy (RT) for prevention of heterotopic ossification (HO) after total hip replacement

    International Nuclear Information System (INIS)

    Heyd, R.; Schopohl, B.; Boettcher, H.D.; Kirchner, J.

    1997-01-01

    Preliminary results of a prospective study which investigates the efficacy of preoperative radiotherapy (RT) for prevention of heterotopic ossification (HO) after total hip arthroplasty are summarized. A total number of 20 hip joints (18 patients) were irradiated with a single dose of 6.0 Gy Brooker grade II). The functional outcome quantified with the Harris score was improved by an average of 37.9 points. The authors conclude that preoperative RT is an effective alternative for postoperative irradiation. (orig.) [de

  4. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. STUDY OF FUNCTIONAL RESULTS OF CEMENTED TOTAL HIP REPLACEMENT BY MOORE’S APPROACH

    Directory of Open Access Journals (Sweden)

    Arunim

    2016-02-01

    Full Text Available INTRODUCTION The total hip replacement (THR has probably become the surgical procedure of choice for vide variety of hip joint disabling diseases. The prosthesis used for THR is often grouped into cemented, cement-less and hybrid ones. There has been increasing trends in use of cement-less components citing more number of complications namely loosening, increased infection rate etc. however with additional cost factors as well. We conducted this study to ascertain whether in a developing country like ours should we really switch over to un-cemented hip replacements dreading such complications or can we still use cemented prosthesis with equally good if not better results. METHODS A study of functional results of cemented total hip replacement was done in patients with varied age groups ranging from 40 years to 75 years with the average age being 54.8 years. 20 patients with 21 diseased hips were treated with cemented total hip replacement by Moore’s posterior approach at NSCB Subharti medical college, Meerut, UP from December 2010 to December 2013 and reviewed thereafter with an average follow-up period of 4.2 years. Average surgical time required was one and half hour. Patients were asked to come for follow up on 1st month, 3rd month and 6th month and then every 6 months and were assessed as per modified Harris Hip Score. RESULTS All the patients were evaluated according to the Modified Harris Hip Scoring system. The results showed 14(67% hips with excellent results, 4(19% with good results, and 3(14% hips with fair results. No poor outcome was noted in this study. 2 cases of dislocation (10% were noted one on the 5th post-operative day and the other occurred after the patient was discharged from the institution. CONCLUSIONS The management of diseased and destroyed hips with chronic pain with cemented total hip replacement is effective and gives stable, mobile and painless hip joint to the patient. Functional results are excellent and

  6. Predictors of revision, prosthetic joint infection and mortality following total hip or total knee arthroplasty in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Cordtz, Rene Lindholm; Zobbe, Kristian; Højgaard, Pil

    2018-01-01

    OBJECTIVES: To investigate predictors of 10-year risk of revision and 1-year risk of prosthetic joint infection (PJI) and death following total hip/total knee arthroplasty (THA/TKA) in (1) patients with rheumatoid arthritis (RA) compared with patients with osteoarthritis (OA); and (2) patients...

  7. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. The efficacy of modified direct lateral versus posterior approach on gait function and hip muscle strength after primary total hip arthroplasty at 12months follow-up

    DEFF Research Database (Denmark)

    Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2016-01-01

    -spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. FINDINGS: Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group......BACKGROUND: The lateral and the posterior approach are the most commonly used procedures for total hip arthroplasty. Due to the detachment of the hip abductors, lateral approach is claimed to cause reduced hip muscle strength and altered gait pattern. However, this has not been investigated...... in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. METHODS: Forty...

  9. Survivorship and complications of total hip arthroplasty in patients with dwarfism.

    Science.gov (United States)

    Modi, Ronuk M; Kheir, Michael M; Tan, Timothy L; Penny, Gregory S; Chen, Chi-Lung; Shao, Hongyi; Chen, Antonia F

    2017-09-19

    Total hip arthroplasty (THA) is a common procedure used to treat bony hip deformities and skeletal dysplasia in dwarfism. These surgeries are often more difficult than conventional THA as they may involve malformed joints and poor bone quality, and may require smaller prostheses. This study aims to investigate whether implant survivorship and revision rates vary among patients with and without dwarfism undergoing THA. A retrospective case-control study was performed for 102 THAs completed between 1997 and 2014 in patients under the height threshold of 147.32 cm. This cohort was matched 1:1.5 with patients of normal height with respect to age, gender, year of surgery, and Charlson comorbidities. All cases had a minimum follow-up of 1 year. A chart review was performed to identify patient and surgical characteristics, including outcomes. Radiographs were assessed for deformity, loosening, and periprosthetic fractures among other factors. The 2-, 5-, and 10-year survivorship of THA in patients with dwarfism was 92.9%, 92.9%, and 80.7%, respectively; and 94.4%, 86.4%, and 86.4% for controls, respectively (p = 0.95). The dwarfism cohort demonstrated an OR of 3.81 and 3.02 for revision for periprosthetic fractures (p = 0.11) and mechanical wear (p = 0.21), respectively. THA in patients with dwarfism achieves comparable results to a non-dwarfism population with regards to implant survivorship; however, there is a trend toward increased periprosthetic fractures and wear-related failures. Surgeons should be aware of this potentially higher risk in this population and take morphological differences into account during surgical planning and technique.

  10. [Diagnosis and therapy of particle disease in total hip arthroplasty].

    Science.gov (United States)

    Müller, M; Wassilew, G; Perka, C

    2015-04-01

    Particle disease is caused by periarticular accumulation of attrition particles and the inflammatory reaction of the body's tissue. This process may result in osteolysis or soft tissue transformation which presents itself symptomless in the beginning and can proceed to aseptic implant loosening, fracture, implant breaking as a result of the inappropriate osseous support and to algetic and destructive soft tissue reactions as well. Attrition particles originate from tribological pairing, and the extent of the attrition or the particle concentration depend on different factors as there are the tribological pairing's material, the head size, the patient's level of activity, and the implant position. Attrition particles can also be found in the range of any modular connection. Particle disease and its resulting morphological alterations of the tribological pairing is one of the most frequent reasons for re-operation in hip endoprosthetics. Georg Thieme Verlag KG Stuttgart · New York.

  11. Recovery in mechanical muscle strength following resurfacing vs standard total hip arthroplasty - a randomised clinical trial

    DEFF Research Database (Denmark)

    Jensen, Carsten; Aagaard, Per; Overgaard, S

    2011-01-01

    rather than implant design per se. Thus, the present data failed to support the hypothesis that R-THA would result in an enhanced strength rehabilitation compared to S-THA. Further, between-limb asymmetry remained present for hip flexors and adductors after 52 wks. Trial registration: NCT01229293....... randomised into (A) standard total hip arthroplasty (S-THA) and (B) resurfacing total hip arthroplasty (R-THA). Pre-surgery assessment and follow-up were conducted (8, 26 and 52 wks). Maximal isometric muscle strength (Nm) and between-limb asymmetry for the knee extensors/flexors, hip adductors....../abductors, hip extensors/flexors were analysed. RESULTS: Maximal knee extensor and hip abductor strength were higher in S-THA than R-THA at 52 wks post-surgery (P ≤ 0.05) and hip extensors tended to be higher in S-THA at 52 wks (P = 0.06). All muscle groups showed substantial between-limb strength asymmetry (7...

  12. Chronic asymptomatic dislocation of a total hip replacement: a case report

    Directory of Open Access Journals (Sweden)

    Lidder Surjit

    2009-08-01

    Full Text Available Abstract Introduction Dislocation of a prosthetic hip is the second most common complication after thromboembolic disease in patients undergoing total hip arthroplasty, with an incidence reported as 0.5 to 20%. Although the period of greatest risk for dislocation has been reported to be within the first few months after surgery, late dislocation occurs more commonly then previously thought. Case presentation A 60-year-old man underwent a right Exeter cemented total hip replacement and was subsequently discharged after appropriate follow-up. He next presented 8 years later complaining of pain in the left groin. An anterioposterior radiograph of the pelvis revealed degenerative changes in the left hip and a dislocated right total hip replacement. The dislocated femoral component had formed a neoacetabulum within the ilium, in which it was freely articulating. He remained pain-free on this side, had 5 cm of true leg length shortening with a good range of movement and was very pleased with his hip replacement. He was later placed on the waiting list for a left total hip replacement. Conclusion This case illustrates that a dislocated total hip replacement may occasionally not cause symptoms that cause significant discomfort or reduction in range of movement. The prosthetic femoral head can form a neoacetabulum allowing a full range of pain-free movement. Furthermore it emphasises that with an increased trend to earlier hospital discharge and shorter follow-up, potential complications may be missed. We urge a low index of suspicion for potential complications and suggest that regular review with radiographic follow-up should be made.

  13. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  14. Primary total hip replacement for displaced subcapital fractures of the femur.

    Science.gov (United States)

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  15. Allogenic bone graft viability after hip revision arthroplasty assessed by dynamic [18F]fluoride ion positron emission tomography

    International Nuclear Information System (INIS)

    Piert, M.; Becker, H.D.; Winter, E.; Becker, G.A.; Bilger, K.; Machulla, H.J.; Mueller-Schauenburg, W.; Bares, R.

    1999-01-01

    The biological fate of allogenic bone grafts in the acetabular cavity and their metabolic activity after acetabular augmentation is uncertain but is most important for the stability of hip implants after hip revision arthroplasty. The aim of this study was to quantify regional bone metabolism after hip replacement operations. Dynamic [ 18 F]fluoride ion positron emission tomography (PET) was used to investigate the metabolic activity of acetabular allogenic bone grafts and genuine bone, either 3-6 weeks (short-term group, n = 9) or 5 months to 9 years (long-term group, n = 10) after hip revision arthroplasty. Applying a three-compartment model, the fluoride influx constant was calculated from individually fitted rate constants (K nlf ) and by Patlak graphical analysis (K pat ). The results were compared with genuine cancellous and cortical acetabular bone of contralateral hips without surgical trauma (n = 7). In genuine cortical bone, K nlf was significantly increased in short- (+140.9%) and long-term (+100.0%) groups compared with contralateral hips. Allogenic bone grafts were characterised by a significantly increased K nlf in the short-term group (+190.9%) compared with contralateral hips, but decreased almost to the baseline levels of contralateral hips (+45.5%) in the long-term. Values of K nlf cor-related with the rate constant K 1 in genuine (r = 0.89, P pat values were highly correlated with K nlf measurements in all regions. (orig.)

  16. Prospective study of ascending venogram following total hip replacement or total knee replacement

    Energy Technology Data Exchange (ETDEWEB)

    Youm, Chang Seon; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yun; Kim, Young Hoo [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1987-04-15

    The ascending leg venogram was performed in one hundred forty six lower extremities on the 7th day following total hip replacement (THR) or total knee replacement (TKR). The results were as follows; 1.Overall incidence of deep vein thrombosis (DVT) in 146 limbs who underwent THR or TKR was 10%: DVT was detected in 8 limbs among 110 limbs following THR (7%) and 6 limbs among 36 limbs following TKR (17%). 2.The anatomic distribution of DVT was as follows: In THR, 12.5% in FV, 25% in FV and PV, 25% in FV and PV and CV, 12.5% in FV and CV, and 25% in CV. In TKR, 100% in CV. 3.There were many anatomic variations in deep veins of lower extremities: Accessory SFV (41 limbs), double PV(24), accessory SFV and double PV(7), duplication of SFV and PV(3), accessory SFV and multiple PV(2), and accessory SFV and double PV(1). 4.There were multiple SFV in 37%, and 19% of these limbs had DVT. It represented statistically higher than 4% in limbs with a single SFV (P-value < 0.05). 5.The incidence of DVT was 8% in cases of multiple PV, and there was no statistically significant difference between these groups and single PV groups. 6.We could assess number of values from popliteal vein to common femoral vein in 72 limbs. Mean number of value was 5.45 and there was no statistically significant difference between groups having valve over 5 and under 5.

  17. Systematic review: Do patient expectations influence treatment outcomes in total knee and total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Haanstra Tsjitske M

    2012-12-01

    Full Text Available Abstract Objective This systematic review aims to summarise all the available evidence related to the association between pre-operative patient expectations (outcome expectations, process expectations and self efficacy expectations and 5 different treatment outcomes (overall improvement, pain, function, stiffness and satisfaction in patients with total knee or total hip arthroplasty at three different follow-op periods (>6 weeks; >6 weeks- ≤6 months; >6 months. Methods English and Dutch language articles were identified through PubMed, EMBASE.com, PsycINFO, CINAHL and The Cochrane Library from inception to September 2012. Articles assessing the association between pre-operative patient expectations and treatment outcomes for TKA/THA in either adjusted or unadjusted analysis were included. Two reviewers, working independently, determined eligibility, rated methodological quality and extracted data on study design, population, expectation measurements, outcome measurements and strength of the associations. Methodological quality was rated by the same reviewers on a 19 item scale. The scores on the quality assessment were taken into account when drawing final conclusions. Results The search strategy generated 2252 unique references, 18 articles met inclusion criteria. Scores on the methodological quality assessment ranged between 6% and 79%. Great variety was seen in definitions and measurement methods of expectations. No significant associations were found between patient expectations and overall improvement, satisfaction and stiffness. Both significant positive and non-significant associations were found for the association between expectations and pain and function. Conclusions There was no consistency in the association between patients’ pre-operative expectations and treatment outcomes for TKA and THA indentified in this systematic review. There exists a need for a sound theoretical framework underlying the construct of

  18. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    International Nuclear Information System (INIS)

    Geijer, Mats; Dunker, Dennis; Collin, David; Goethlin, Jan H.

    2012-01-01

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  19. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Mats (Center for Medical Imaging and Physiology, Skaane University Hospital, Lund University, Lund (Sweden)), Email: mats@geijer.info; Dunker, Dennis; Collin, David; Goethlin, Jan H. (Department of Radiology, Sahlgrenska University Hospital, Moelndal (Sweden))

    2012-03-15

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  20. Aquatic exercises versus land based exercises for elderly patients after a total hip replacement

    OpenAIRE

    Miroljub Jakovljevič; Renata Vauhnik

    2011-01-01

    Background: Aquatic therapy allows secure, active exercise with pain reduction using a combination of the water’s buoyancy, hydrostatic pressure, resistance and warmth. By aquatic therapy, elderly patients after total hip replacement can achieve more positive effects than by land-based exercise. The aim of the study was to investigate the use of aquatic-based exercises in the rehabilitation programme after a hip fracture surgery in elderly adults. Results: Both groups, regardless of the ty...

  1. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.

    Science.gov (United States)

    Hambright, D; Hellman, M; Barrack, R

    2018-01-01

    The aims of this study were to examine the rate at which the positioning of the acetabular component, leg length discrepancy and femoral offset are outside an acceptable range in total hip arthroplasties (THAs) which either do or do not involve the use of intra-operative digital imaging. A retrospective case-control study was undertaken with 50 patients before and 50 patients after the integration of an intra-operative digital imaging system in THA. The demographics of the two groups were comparable for body mass index, age, laterality and the indication for surgery. The digital imaging group had more men than the group without. Surgical data and radiographic parameters, including the inclination and anteversion of the acetabular component, leg length discrepancy, and the difference in femoral offset compared with the contralateral hip were collected and compared, as well as the incidence of altering the position of a component based on the intra-operative image. Digital imaging took a mean of five minutes (2.3 to 14.6) to perform. Intra-operative changes with the use of digital imaging were made for 43 patients (86%), most commonly to adjust leg length and femoral offset. There was a decrease in the incidence of outliers when using intra-operative imaging compared with not using it in regard to leg length discrepancy (20% versus 52%, p = 0.001) and femoral offset inequality (18% versus 44%, p = 0.004). There was also a difference in the incidence of outliers in acetabular inclination (0% versus 7%, p = 0.023) and version (0% versus 4%, p = 0.114) compared with historical results of a high-volume surgeon at the same centre. The use of intra-operative digital imaging in THA improves the accuracy of the positioning of the components at THA without adding a substantial amount of time to the operation. Cite this article: Bone Joint J 2018;100B(1 Supple A):36-43. ©2018 The British Editorial Society of Bone & Joint Surgery.

  2. Bone mineral density in patients with destructive arthrosis of the hip joint.

    Science.gov (United States)

    Okano, Kunihiko; Aoyagi, Kiyoshi; Enomoto, Hiroshi; Osaki, Makoto; Chiba, Ko; Yamaguchi, Kazumasa

    2014-05-01

    Recent reports have shown the existence of subchondral insufficiency fracture in rapidly destructive arthrosis of the hip joint (RDA), and the findings suggest that osteopenia is related to the pathogenesis of the rapid progression of this disease. Therefore, we measured bone mineral density (BMD) in RDA patients. We measured BMD of the lumbar spine, radius, and calcaneus using dual-energy X-ray absorptiometry in 19 patients with RDA and 75 with osteoarthritis of the hip (OA) and compared BMD at different skeletal sites between RDA and OA patients. No significant differences were observed in BMD of the lumbar spine, ultradistal radius, mid-radius, and calcaneous between the RDA and OA groups. Our data suggest that RDA is not accompanied by generalized osteoporosis. Factors other than generalized bone status, for example, BMD around the affected hip joint before destruction, need to be analyzed to elucidate the pathophysiological mechanism of RDA.

  3. The principle of low frictional torque in the Charnley total hip replacement.

    Science.gov (United States)

    Wroblewski, B M; Siney, P D; Fleming, P A

    2009-07-01

    The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.

  4. A simple technique to strengthen the initial and mid-term to long-term stability of the cup during total hip arthroplasty in developmental dysplasia of the hip.

    Science.gov (United States)

    Guan, Mingqiang; Zhou, Guanming; Li, Xue

    2018-04-01

    To assess the effects of a technique of cup blocking screws combined with impaction bone grafting during total hip arthroplasty (THA) for patients with developmental dysplasia of the hip (DDH). From August 2011 to July 2015, 53 patients (59 hips) with DDH in our hospital were treated with THA using the technique of cup blocking screws combined with impaction particulate bone grafting. These patients were prospectively followed, and the clinical and imaging results were collected. Harris hip score (HHS) was raised from 41.24 before surgery to 91.49 at the latest follow-up (p less than 0.001). Length discrepancy (LLD) was reduced from 28.97 mm before surgery to 6.08 mm after surgery (p less than 0.001). No loosening of the cup was detected at the last follow-up. The differences were insignificant in cup inclination and rate of cup coverage among the 3 groups of Crowe type II, type III, and type IV DDH (p greater than 0.05). The technique of cup blocking screws combined with impaction particulate bone grafting is simple and reliable, and it not only simplifies the attainment of initial stability, but also strengthens the mid-term to long-term stability during THA in DDH.

  5. Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing

    Directory of Open Access Journals (Sweden)

    Vicky Bouffard

    2011-01-01

    Full Text Available Objective. To compare center of mass (COM compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA and hip resurfacing (HR. Design. Observational study. Setting. Outpatient biomechanical laboratory. Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip prosthetic joint center (HPJC and the COM. The ratio (RHPJC-COM and the variability (CVHPJC-COM were compared between groups. Hip flexor, abductor, and adductor muscle strength was also correlated between groups while radiographic measurements were correlated with the outcome measures. Results. In the frontal plane, HR shows less variability than healthy controls at push-off and toe-off and RHPJC-COM is correlated with the muscle strength ratios (FRABD at heel contact, maximal weight acceptance, and mid stance. In the sagittal plane, LDH-THA has a higher RHPJC-COM than healthy controls at push-off, and CVHPJC-COM is significantly correlated with FRFLEX. Conclusions. One year after surgery, both groups of patients, LDH-THA and HR, demonstrate minor compensations at some specific instant of the gait cycle, in both frontal and sagittal planes. However, their locomotion pattern is similar to the healthy controls.

  6. Effect of hydroxyapatite coating on risk of revision after primary total hip arthroplasty in younger patients: findings from the Danish Hip Arthroplasty Registry

    DEFF Research Database (Denmark)

    Paulsen, Aksel; Pedersen, Alma B; Johnsen, Søren P

    2007-01-01

    BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip Arthropla......BACKGROUND: The effect of hydroxyapatite (HA) on implant survival in the medium and long term is uncertain. We studied the effect of HA coating of uncemented implants on the risk of cup and stem revision in primary total hip arthroplasty (THA). PATIENTS AND METHODS: Using the Danish Hip...

  7. Epsilon Aminocaproic Acid to Reduce Blood Loss and Transfusion After Total Hip and Total Knee Arthroplasty.

    Science.gov (United States)

    Hobbs, Juliann C; Welsby, Ian J; Green, Cynthia L; Dhakal, Ishwori B; Wellman, Samuel S

    2018-01-01

    Total hip and knee arthroplasty (THA and TKA) are associated with significant blood loss and some patients require postoperative blood transfusion. While tranexamic acid has been studied extensively among this population, we tested the hypothesis that epsilon aminocaproic acid (EACA) can reduce blood loss and transfusion after joint arthroplasty. In April 2014, our Veterans Affairs Medical Center introduced a protocol to administer EACA during THA and TKA. No antifibrinolytics were used previously. We retrospectively compared blood loss and incidence of transfusion among patients who underwent primary arthroplasty in the year before standardized administration of EACA with patients having the same procedures the following year. Blood loss was measured as delta hemoglobin (preoperative hemoglobin - hemoglobin on postoperative day 1). All patients undergoing primary THA or TKA were included. Patients having revision surgery were excluded. We identified 185 primary arthroplasty patients from the year before and 184 from the year after introducing the EACA protocol. There were no changes in surgical technique or attending surgeons during this period. Delta hemoglobin was significantly lower in the EACA group (2.7 ± 0.8 mg/dL) compared to the control group (3.4 ± 1.1 mg/dL) (P blood transfusion was also significantly lower in the EACA group (2.7%) compared to the control group (25.4%) (P transfusion following introduction of the EACA protocol in patients undergoing primary arthroplasty. EACA offers a lower cost alternative to TXA for reducing blood loss and transfusion in this population. Published by Elsevier Inc.

  8. Diagnostic value of bone scintigraphy with sup(99m)Tc-pyrophosphate for evaluation of complications after hip joint replacement

    International Nuclear Information System (INIS)

    Baumer, J.F.

    1979-01-01

    For 102 patients with complaints after total hip replacement, bone scintigraphies with sup(99m)Tc have been made in addition to the usual examinations. 95 of these patients had to be operated once more, whereas the infected endoprosteses detected in the remaining 7 patients have been treated for the time being by non-surgical measures. In 68 patients, the examination revealed an aseptic loosening of the total endoprosthesis, including fracture of the diaphysis in 19 cases. In one case, a replacement of the prosthesis had been necessary in spite of the alloarthroplasty being firmly fixed in the right place. The bacterioscopic and bacteriologic investigations clearly revealed an infection of the environment of the prosthesis, in 27 patients, whereas the findings obtained on 6 other patients have not been as unambiguons. 85% of the patients with septic complications showed an increased E.S.R., however only 26% of the patients with aseptic complications. In only 47% of the patients with infection of the hip joint, bacteria have been found in the hip joint puncture fluid, whereas the bacteriological examination of tissue taken from the environment of the artificial hip joint during the operation revealed no increase in bacteria in only one case (5%). In 4 patients (20%), the bacterioscopic findings showed no signs of an acute infection, although saprophytic germs had been isolated from the environment of the prosthesis. 78% of the cases with loosening of the prosthesis and 11% of the infections have been detected by X-ray examination. The nuclear medical examination showed normal radionuclide accumulation in 30% of the cases with loosened prosthesis and in 4% of the infections, for 6% each of the two complications the scintigrams yielded no unambiguous results. In 4 patients (40%) with total hip joint replacement on both sides, enhanced radionuclide accumulation has been abserved even on the symptom-free side. (orig./AJ) [de

  9. [Evaluation of the Function and Quality of Life after Total Hip Arthroplasty by Different Approaches].

    Science.gov (United States)

    Araújo, Paulo; Machado, Luís; Cadavez, Duarte; Mónaco, Lisete; Januário, Filipa; Luís, Lisete; Bártolo, Mafalda

    2017-09-29

    To assess the function and quality of life in patients undergoing total hip arthroplasty distinguishing two surgical approaches (posterior / anterolateral) used by the Orthopedics department of Centro Hospitalar de Leiria. Retrospective study of 94 patients subject to unilateral hip replacement surgery, using the 'Hip Osteoarthritis Outcome Score' (HOOS LK 2.0) questionnaire, the Trendelenburg test and evaluation of muscle strength of the hip abductor muscles with dynamometer. Patients were evaluated at six months, 12 months, 18 months and 24 months after surgery. The study revealed that 97.9% patients completed the rehabilitation program. The postoperative evolution (six to 24 months) does not appear to have any differences in results when comparing both approaches. At six months the patient operated by the anterolateral approach showed worse results when compared with the posterior approach, in particular in Hip Osteoarthritis Outcome Score pain, in Hip Osteoarthritis Outcome Score symptoms and Hip Osteoarthritis Outcome Score activities of daily living. After 24 months, no differences between the two surgical approaches were found. Of the 94 patients evaluated, the Trendelenburg test was positive in 31% of patients of which 81.9% corresponds to patients operated by the anterolateral approach. Muscle strength of the abductors of the operated hip was clearly lower in the anterolateral approach at six months, 12 months, and 24 months. This study showed that, in the first six months after total hip arthroplasty, the patients operated by the posterior approach were, according to the HOOS questionnaire, less symptomatic, and presented with better quality of life and less impact on activities of daily living and in sport and leisure when compared with the patients operated by the anterolateral approach. However, these differences were matched over the 24 months. Moreover, the results of muscle strength of the abductor muscles of the hip were clearly superior in

  10. Improvement in quality of lifesix months after primary total hip arthroplasty in a Pakistani population.

    Science.gov (United States)

    Zubairi, Akbar Jaleel; Bin Mahmood, Syed Usman; Ali, Moiz; Noordin, Shahryar

    2016-10-01

    This prospective, cohort study was carried out to assess the improvement in quality of life of patients undergoing elective primary total hip arthroplasty (THA). It was conducted at the orthopaedic department of the Aga Khan University Hospital, Karachi, from June 2014 to May 2015, and comprised patients who had undergone THA. A total of 89 patients having a mean age of 41.5±12.0 years with a baseline core outcomes measure index (COMI)-hip score of > 3.5 were included. A decrease in COMI-hip score by >3 points six months post-operatively was considered improvement in quality of life. Patient satisfaction with restriction to squatting was assessed separately. The mean reduction in COMI-hip was 4.9±1.3 with 83(93%) patients experiencing significant improvement in quality of life. Age >50 years and American Society of Anaesthesiologists (ASA) level >III was significantly associated with no improvement in quality of life. Most patients were satisfied with their disability to squat irrespective of COMI-hip score. THA was found to be associated with significant improvement in quality of life and COMI-hip score was applicable in our population despite its inability to assess disability with restriction in squatting.

  11. Prospective analyses of female urinary incontinence symptoms following total hip arthroplasty.

    Science.gov (United States)

    Okumura, Keiko; Yamaguchi, Kumiko; Tamaki, Tatsuya; Oinuma, Kazuhiro; Tomoe, Hikaru; Akita, Keiichi

    2017-04-01

    Some patients with hip osteoarthritis report that urinary incontinence (UI) is improved following total hip arthroplasty (THA). However, the type and severity of UI remain unclear. In this study, we hypothesize that both stress urinary incontinence (SUI) and urge urinary incontinence (UUI) are improved after THA. We assess the characteristics of UI and discuss the anatomical factors related to UI and THA for improved treatment outcome. Fifty patients with UI who underwent direct anterior-approach THA were evaluated. Type of UI was assessed using four questionnaires: Core Lower Urinary Tract Symptom Score (CLSS), Urogenital Distress Inventory Short Form (UDI-6), International Prostate Symptom Score (IPSS), and Overactive Bladder Symptom Score (OABSS). Uroflowmetry and postvoid residual urine were measured using ultrasound technology. Hip-joint function was evaluated using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM). Of the 50 patients, 21 had SUI, 16 had mixed urinary incontinence (MUI), and eight had urgency urinary incontinence (UUI). In total, 36 patients were better than improved (72 %). The rate of cured and improved was 76 % for SUI, 100 % MUI, and 50 % UUI. The improvement of ROM was more significant in cured or improved patients than in stable or worse patients. Improvement in mild UI may be an added benefit for those undergoing THA for hip-joint disorders. These data suggest that for patients with hip-joint disorder, hip-joint treatment could prove to also be a useful treatment for UI.

  12. Influence of bone density on the cement fixation of femoral hip resurfacing components.

    Science.gov (United States)

    Bitsch, Rudi G; Jäger, Sebastian; Lürssen, Marcus; Loidolt, Travis; Schmalzried, Thomas P; Clarius, Michael

    2010-08-01

    In clinical outcome studies, small component sizes, female gender, femoral shape, focal bone defects, bad bone quality, and biomechanics have been associated with failures of resurfacing arthroplasties. We used a well-established experimental setup and human bone specimens to analyze the effects of bone density on cement fixation of femoral hip resurfacing components. Thirty-one fresh frozen femora were prepared for resurfacing using the original instruments. ASR resurfacing prostheses were implanted after dual-energy X-ray densitometer scans. Real-time measurements of pressure and temperature during implantation, analyses of cement penetration, and measurements of micro motions under torque application were performed. The associations of bone density and measurement data were examined calculating regression lines and multiple correlation coefficients; acceptability was tested with ANOVA. We found significant relations between bone density and micro motion, cement penetration, cement mantle thickness, cement pressure, and interface temperature. Mean bone density of the femora was 0.82 +/- 0.13 g/cm(2), t-score was -0.7 +/- 1.0, and mean micro motion between bone and femoral resurfacing component was 17.5 +/- 9.1 microm/Nm. The regression line between bone density and micro motion was equal to -56.7 x bone density + 63.8, R = 0.815 (p density scans are most helpful for patient selection in hip resurfacing, and a better bone quality leads to higher initial component stability. A sophisticated cementing technique is recommended to avoid vigorous impaction and incomplete seating, since increasing bone density also results in higher cement pressures, lower cement penetration, lower interface temperatures, and thicker cement mantles. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Pre-operative ambulatory measurement of asymmetric lower limb loading during walking in total hip arthroplasty patients

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, D.; Lecumberri, Pablo; Verdonschot, Nicolaas Jacobus Joseph; Pakvis, Dean; Veltink, Petrus H.

    2013-01-01

    The main goal of this study was to investigate how mobility characteristics during walking, relate to gait velocity and questionnaire outcomes of patients with hip osteoarthritis in an outpatient setting. Methods 22 patients with primary osteoarthritis of the hip selected for a total hip

  14. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    Science.gov (United States)

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing

  15. Dislocation of total hip replacement in patients with fractures of the femoral neck.

    Science.gov (United States)

    Enocson, Anders; Hedbeck, Carl-Johan; Tidermark, Jan; Pettersson, Hans; Ponzer, Sari; Lapidus, Lasse J

    2009-04-01

    Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach. We included 713 consecutive hips in a series of 698 patients (573 females) who had undergone a primary total hip replacement (n = 311) for a non-pathological, displaced femoral neck fracture (Garden III or IV) or a secondary total hip replacement (n = 402) due to a fracture-healing complication after a femoral neck fracture. We used Cox regression to evaluate factors associated with prosthetic dislocation after the operation. Age, sex, indication for surgery, the surgeon's experience, femoral head size, and surgical approach were tested as independent factors in the model. The overall dislocation rate was 6%. The anterolateral surgical approach was associated with a lower risk of dislocation than the posterolateral approach with or without posterior repair (2%, 12%, and 14%, respectively (p replacement in patients with femoral neck fractures.

  16. Variation in age and physical status prior to total knee and hip replacement surgery

    DEFF Research Database (Denmark)

    Ackerman, Ilana N; Dieppe, Paul A; March, Lyn M

    2009-01-01

    OBJECTIVE: To investigate whether variation exists in the preoperative age, pain, stiffness, and physical function of people undergoing total knee replacement (TKR) and total hip replacement (THR) at several centers in Australia and Europe. METHODS: Individual Western Ontario and McMaster Univers...

  17. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the tra...

  18. Quantitative 3D analysis of bone in hip osteoarthritis using clinical computed tomography

    International Nuclear Information System (INIS)

    Turmezei, Tom D.; Treece, Graham M.; Gee, Andrew H.; Fotiadou, Anastasia F.; Poole, Kenneth E.S.

    2016-01-01

    To assess the relationship between proximal femoral cortical bone thickness and radiological hip osteoarthritis using quantitative 3D analysis of clinical computed tomography (CT) data. Image analysis was performed on clinical CT imaging data from 203 female volunteers with a technique called cortical bone mapping (CBM). Colour thickness maps were created for each proximal femur. Statistical parametric mapping was performed to identify statistically significant differences in cortical bone thickness that corresponded with the severity of radiological hip osteoarthritis. Kellgren and Lawrence (K and L) grade, minimum joint space width (JSW) and a novel CT-based osteophyte score were also blindly assessed from the CT data. For each increase in K and L grade, cortical thickness increased by up to 25 % in distinct areas of the superolateral femoral head-neck junction and superior subchondral bone plate. For increasing severity of CT osteophytes, the increase in cortical thickness was more circumferential, involving a wider portion of the head-neck junction, with up to a 7 % increase in cortical thickness per increment in score. Results were not significant for minimum JSW. These findings indicate that quantitative 3D analysis of the proximal femur can identify changes in cortical bone thickness relevant to structural hip osteoarthritis. (orig.)

  19. Early results of metal on metal articulation total hip arthroplasty in young patients.

    Science.gov (United States)

    Mohamad, J A; Kwan, M K; Merican, A M; Abbas, A A; Kamari, Z H; Hisa, M K; Ismail, Z; Idrus, R M

    2004-12-01

    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.

  20. Bone mineral density difference between right and left hip during ageing

    DEFF Research Database (Denmark)

    Schwarz, P.; Jørgensen, Niklas Rye; Jensen, L.T.

    2011-01-01

    be affected by significant left-right difference in hip BMD, especially in the old. The purpose of our study was to ascertain the difference in BMD measurement of the two hips in a population of Caucasian community dwelling women older than 65 years invited for screening. We found that bilateral BMD...... found an increasing difference between the hips with increasing age and this difference was up to 9.1% in the women older than 70 years when evaluating femoral neck, meaning that the diagnosis of osteoporosis in a subset of patients would depend on whether the left or right hip was scanned. When...... measurements were only moderately correlated at the femoral neck and total hip. In a significant number of the screened elderly women, we found that the DXA differences changed the diagnosis of each woman from either normal BMD to osteopenia or visa versa or from osteopenia to osteoporosis or visa versa. We...

  1. Bone Mineral Density difference between Right and Left Hip during Ageing

    DEFF Research Database (Denmark)

    Schwarz, P; Jørgensen, NR; Jensen, LT

    2011-01-01

    be affected by significant left-right difference in hip BMD, especially in the old. The purpose of our study was to ascertain the difference in BMD measurement of the two hips in a population of Caucasian community dwelling women older than 65 years invited for screening. We found that bilateral BMD...... found an increasing difference between the hips with increasing age and this difference was up to 9.1% in the women older than 70 years when evaluating femoral neck, meaning that the diagnosis of osteoporosis in a subset of patients would depend on whether the left or right hip was scanned. When...... measurements were only moderately correlated at the femoral neck and total hip. In a significant number of the screened elderly women, we found that the DXA differences changed the diagnosis of each woman from either normal BMD to osteopenia or visa versa or from osteopenia to osteoporosis or visa versa. We...

  2. AQUILA: assessment of quality in lower limb arthroplasty. An expert Delphi consensus for total knee and total hip arthroplasty.

    Science.gov (United States)

    Pijls, Bart G; Dekkers, Olaf M; Middeldorp, Saskia; Valstar, Edward R; van der Heide, Huub J L; Van der Linden-Van der Zwaag, Henrica M J; Nelissen, Rob G H H

    2011-07-22

    In the light of both the importance and large numbers of case series and cohort studies (observational studies) in orthopaedic literature, it is remarkable that there is currently no validated measurement tool to appraise their quality. A Delphi approach was used to develop a checklist for reporting quality, methodological quality and generalizability of case series and cohorts in total hip and total knee arthroplasty with a focus on aseptic loosening. A web-based Delphi was conducted consisting of two internal rounds and three external rounds in order to achieve expert consensus on items considered relevant for reporting quality, methodological quality and generalizability. The internal rounds were used to construct a master list. The first external round was completed by 44 experts, 35 of them completed the second external round and 33 of them completed the third external round. Consensus was reached on an 8-item reporting quality checklist, a 6-item methodological checklist and a 22-item generalizability checklist. Checklist for reporting quality, methodological quality and generalizability for case series and cohorts in total hip and total knee arthroplasty were successfully created through this Delphi. These checklists should improve the accuracy, completeness and quality of case series and cohorts regarding total hip and total knee arthroplasty.

  3. Quantitative 3D analysis of bone in hip osteoarthritis using clinical computed tomography.

    Science.gov (United States)

    Turmezei, Tom D; Treece, Graham M; Gee, Andrew H; Fotiadou, Anastasia F; Poole, Kenneth E S

    2016-07-01

    To assess the relationship between proximal femoral cortical bone thickness and radiological hip osteoarthritis using quantitative 3D analysis of clinical computed tomography (CT) data. Image analysis was performed on clinical CT imaging data from 203 female volunteers with a technique called cortical bone mapping (CBM). Colour thickness maps were created for each proximal femur. Statistical parametric mapping was performed to identify statistically significant differences in cortical bone thickness that corresponded with the severity of radiological hip osteoarthritis. Kellgren and Lawrence (K&L) grade, minimum joint space width (JSW) and a novel CT-based osteophyte score were also blindly assessed from the CT data. For each increase in K&L grade, cortical thickness increased by up to 25 % in distinct areas of the superolateral femoral head-neck junction and superior subchondral bone plate. For increasing severity of CT osteophytes, the increase in cortical thickness was more circumferential, involving a wider portion of the head-neck junction, with up to a 7 % increase in cortical thickness per increment in score. Results were not significant for minimum JSW. These findings indicate that quantitative 3D analysis of the proximal femur can identify changes in cortical bone thickness relevant to structural hip osteoarthritis. • CT is being increasingly used to assess bony involvement in osteoarthritis • CBM provides accurate and reliable quantitative analysis of cortical bone thickness • Cortical bone is thicker at the superior femoral head-neck with worse osteoarthritis • Regions of increased thickness co-locate with impingement and osteophyte formation • Quantitative 3D bone analysis could enable clinical disease prediction and therapy development.

  4. Total hip arthroplasty and perioperative oral carbohydrate treatment: a randomised, double-blind, controlled trial.

    Science.gov (United States)

    Harsten, Andreas; Hjartarson, Hjörtur; Toksvig-Larsen, Sören

    2012-06-01

    Perioperative oral carbohydrate intake is beneficial to general surgery patients. Total hip arthroplasty is a common surgical procedure, and even a moderate improvement in patient outcome could have a significant effect on the resources needed for these patients. However, few studies have focused on the effects of carbohydrate intake on orthopaedic patients. The purpose of this study was to investigate if perioperative oral carbohydrate intake alters the postoperative course for patients undergoing total hip arthroplasty. The primary hypothesis was that pain scores would be lower in patients treated with carbohydrate. A randomised, double-blind, controlled trial. This study was carried out between September 2009 and April 2011 at a district Swedish hospital that specialises in orthopaedic surgery. Sixty ASA physical status I-III patients scheduled for elective total hip arthroplasty were included. Exclusion criteria were obesity, diabetes, prior hip surgery to the same hip, ongoing infection, immunological deficiency or age less than 50 or more than 80 years. Patients were given 400 ml of either an oral 12.5% carbohydrate solution or a placebo beverage (flavoured water) 1.5 h before and 2 h after surgery. Visual analogue scales were used to score six discomfort parameters. Immediately prior to surgery, the carbohydrate-treated patients were less hungry (median score 9.5 vs. 22 mm) and experienced less nausea (0 vs. 1.5 mm) (Phip arthroplasty.

  5. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  6. Primary Total Hip Replacement for a Femoral Neck Fracture in a Below-Knee Amputee

    OpenAIRE

    Masmoudi, Karim; Rbai, H?di; Fradj, Ayman Ben; Sa?dena, Jecem; Boughattas, Anouar

    2016-01-01

    Introduction: Femoral neck fracture on amputated limb is an uncommon lesion and challenging to manage. Case Report: We report a case of a displaced neck fracture of the left femur in a 57-year-old female. She underwent at the age of the three a below-knee amputation of the ipsilateral limb for post traumatic ischemia. The fracture was managed by a total hip arthroplasty (THA), as a primary procedure. In this article we describe our experience of this unusual entity. Conclusion: Total hip arth...

  7. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    Science.gov (United States)

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  8. Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty.

    Science.gov (United States)

    Park, Kyung Soon; Diwanji, Sanket R; Kim, Hyung Keun; Song, Eun Kyoo; Yoon, Taek Rim

    2009-08-01

    Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.

  9. Early patient-reported outcomes versus objective function after total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Luna, I E; Kehlet, H; Peterson, B

    2017-01-01

    AIMS: The purpose of this study was to assess early physical function after total hip or knee arthroplasty (THA/TKA), and the correlation between patient-reported outcome measures, physical performance and actual physical activity (measured by actigraphy). PATIENTS AND METHODS: A total of 80...... patients aged 55 to 80 years undergoing THA or TKA for osteoarthritis were included in this prospective cohort study. The main outcome measure was change in patient reported hip or knee injury and osteoarthritis outcome score (HOOS/KOOS) from pre-operatively until post-operative day 13 (THA) or 20 (TKA...

  10. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai, MD

    2017-09-01

    Full Text Available Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  11. Assessment of total hip arthroplasty as a predisposing factor for ischiofemoral impingement

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Adriana L.; Azevedo, Debora C.; Eajazi, Alireza; Palmer, William E.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Kwon, Young-Min [Massachusetts General Hospital and Harvard Medical School, Department of Orthopedics, Boston, MA (United States); Torriani, Martin [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention Department of Radiology, Boston, MA (United States)

    2015-12-15

    To examine the effect of total hip arthroplasty (THA) on ischiofemoral (IF) and quadratus femoris (QF) spaces with the hypothesis that THA does not affect ischiofemoral relationships. The study was IRB approved and complied with HIPAA guidelines. We identified consecutive MR examinations (pelvis and/or hip) obtained at our institution in adults (≥18 years old) screened for THA-related complications. Native hips from the same individuals served as controls. We collected medical record data including age, gender, surgical history, and THA designs. Two radiologists independently measured the IF-RAD and IF-MRI (IF space on radiographs and MR imaging, respectively) and QF space (on MR imaging). Groups were compared using ANCOVA controlled for gender. The study group comprised 250 hips (132 subjects; 162 post-THA and 88 native hips). Subjects were aged 59 ± 10 years, with 66 males and 66 females. Comparison of IF-MRI and QF spaces between native and post-THA hips showed no differences (P > 0.12) and IF-RAD was higher in post-THA subjects (P = 0.01). No differences in the IF-MRI and QF spaces were present between native hips and different THA designs (P > 0.4). IF-RAD of metal-on-metal THA was higher than that of native hips (P = 0.01) and trended higher than ceramic-on-polyethylene THA (P = 0.08), with the remaining comparisons showing no significant differences (P > 0.4). Radiographic- and MRI-based measures in patients with standard THA do not show narrowing of IF and QF spaces. (orig.)

  12. [Stress analysis of femoral stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer].

    Science.gov (United States)

    Oomori, H; Imura, S; Gesso, H

    1992-04-01

    To develop stem design achieving primary fixation of stems and effective load transfer to the femur, we studied stress analysis of stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer in stem-bone interface. The results of analyses of stem-bone interface stresses and von Mises stresses at the cortical bones indicated that ideal stem design features would be as follows: 1) Sufficient length, with the distal end extending beyond the isthmus region. 2) Maximum possible width, to contact the cortical bones in the isthmus region. 3) No collars but a lateral shoulder at the proximal portion. 4) A distal tip, to contact the cortical bones at the distal portion.

  13. Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.

    Science.gov (United States)

    Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David

    2018-03-29

    Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.

  14. Risk factors for total hip arthroplasty aseptic revision.

    Science.gov (United States)

    Khatod, Monti; Cafri, Guy; Namba, Robert S; Inacio, Maria C S; Paxton, Elizabeth W

    2014-07-01

    The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001-12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%-97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Preoperative irradiation for prevention of heterotopic ossification following prosthetic total hip replacement. Results of a prospective study in 462 hips

    Energy Technology Data Exchange (ETDEWEB)

    Koelbl, O.; Seufert, J.; Pohl, F.; Flentje, M. [Univ. Wuerzburg (Germany). Klinik and Poliklinik for Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Hospital, Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Hospital, Bad Mergentheim (Germany). Inst. of Radiology

    2003-11-01

    Background: The effectiveness of pre- or postoperative radiotherapy for prevention of heterotopic ossification (HO) following total hip replacement (THR) has already been demonstrated in the past. Thereby, in most studies using preoperative radiotherapy patients were irradiated < 6 h before surgery. The purpose of this prospective study was to analyze the effectiveness of preoperative irradiation on the evening before surgery and to identify risk factors for HO in a homogeneous collective of patients. Patients and Methods: From July 1997 to July 2001, 416 patients (462 hips; 235 males, 227 females) received preoperative radiotherapy of the hip on the evening before surgery with a 7-Gy single fraction. The patients' median age was 67.1 years. The most frequent indication for radiotherapy was hypertrophic osteoarthritis (383 hips, 82.9%). Treatment results were assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). The analysis of radiographs was performed according to the Brooker score. Results: The overall incidence of HO was 18.1% (n = 84), Brooker score 1 12.3% (n = 57), score 2 3.9% (n = 18), score 3 1.5% (n = 7), and score 4 0.4% (n = 2). Sex, body height, hypertrophic osteoarthritis of higher degree, size of the femoral component of the prosthesis, previous ipsi- or contralateral HO, and short course of nonsteroidal anti-inflammatory drug (diclofenac) therapy significantly influenced the HO rate in univariate analysis. In multivariate analysis, an interdependence of prosthesis size, sex and patient's height was found. From these three variables, only prosthesis size was statistically significant in multivariate analysis. The cumulative dose of diclofenac ({<=} 300 mg or > 300 mg) within the first 7 postoperative days and previous ipsi- or contralateral HO influenced the incidence of HO in multivariate analysis. Conclusion: Preoperative radiotherapy on the evening before surgery is an effective treatment

  16. Milk and yogurt consumption are linked with higher bone mineral density but not with hip fracture: the Framingham Offspring Study.

    Science.gov (United States)

    Sahni, Shivani; Tucker, Katherine L; Kiel, Douglas P; Quach, Lien; Casey, Virginia A; Hannan, Marian T

    2013-01-01

    Dairy foods are a complex source of essential nutrients. In this study, fluid dairy intake, specifically milk, and yogurt intakes were associated with hip but not spine bone mineral density (BMD), while cream may adversely influence BMD, suggesting that not all dairy products are equally beneficial for the skeleton. This study seeks to examine associations of milk, yogurt, cheese, cream, most dairy (total dairy without cream), and fluid dairy (milk + yogurt) with BMD at femoral neck (FN), trochanter (TR), and spine, and with incident hip fracture over 12-year follow-up in the Framingham Offspring Study. Three thousand two hundred twelve participants completed a food frequency questionnaire (1991–1995 or 1995–1998) and were followed for hip fracture until 2007 [corrected]. Two thousand five hundred and six participants had DXA BMD (1996-2001). Linear regression was used to estimate adjusted mean BMD while Cox-proportional hazards regression was used to estimate adjusted hazard ratios (HR) for hip fracture risk. Final models simultaneously included dairy foods adjusting for each other. Mean baseline age was 55 (±1.6) years, range 26-85. Most dairy intake was positively associated with hip and spine BMD. Intake of fluid dairy and milk was related with hip but not spine BMD. Yogurt intake was associated with TR-BMD alone. Cheese and cream intakes were not associated with BMD. In final models, yogurt intake remained positively associated with TR-BMD, while cream tended to be negatively associated with FN-BMD. Yogurt intake showed a weak protective trend for hip fracture [HR(95%CI), ≤4 serv/week, 0.46 (0.21-1.03) vs. >4 serv/week, 0.43 (0.06-3.27)]. No other dairy groups showed a significant association (HRs range, 0.53-1.47) with limited power (n, fractures = 43). Milk and yogurt intakes were associated with hip but not spine BMD, while cream may adversely influence BMD. Thus, not all dairy products are equally beneficial for the skeleton. Suggestive fracture

  17. Comparison of total hip arthroplasty in osteoarthritis of mechanical and rheumatologic causes

    Science.gov (United States)

    Ejnisman, Leandro; Leonhardt, Nathalia Zalc; Fernandes, Laura Fillipini Lorimier; Leonhardt, Marcos de Camargo; Vicente, José Ricardo Negreiros; Croci, Alberto Tesconi

    2014-01-01

    Objective: To compare the use of uncemented implants in total hip arthroplasty in patients with rheumathologic diseases and mechanical osteoarthrosis. Methods: We retrospectively evaluated 196 patients who were operated by the Hip and Arthroplasty Surgery Group of the IOT-HCFMUSP between 2005 and 2009. Patients were divided into two groups: mechanical causes (165 patients) and rheumathologic causes (31 patients). Groups were compared between each other in age, gender and follow-up time. Osseointegration rate and percentage of failure in arthroplasty were evaluated. Results: No statistically significant difference was found in osseointegration rates (in both femoral and acetabular components) in both groups. The rates of revision surgery and implant survival also did not show statistically significant differences. Conclusion: The use of uncemented total hip arthroplasty did not show worse results in rheumathologic patients. Level of Evidence III, Retrospective Case Control Study. PMID:24644419

  18. Automated bone segmentation from large field of view 3D MR images of the hip joint

    Science.gov (United States)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S.; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-10-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head-neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone-cartilage interfaces for potential cartilage segmentation.

  19. Lifestyle and health-related quality of life in Asian patients with total hip arthroplasties.

    Science.gov (United States)

    Fujita, Kimie; Xia, Zhenlan; Liu, Xueqin; Mawatari, Masaaki; Makimoto, Kiyoko

    2014-09-01

    Total hip arthroplasty reduces pain and restores physical function in patients with hip joint problems. This study examined lifestyle and health-related quality of life before and after total hip arthroplasty in Japanese and Chinese patients. Two hospitals in China recruited 120 patients and 120 Japanese patients matched by age and operative status were drawn from a prospective cohort database. Oxford Hip Score, EuroQol, and characteristics of Asian lifestyle and attitudes toward the operation were assessed. There were no differences between patients from the two countries in quality-of-life-scale scores: postoperative patients had significantly better quality-of-life scores than preoperative patients in both countries. In China, patients who reported that living at home was inconvenient had significantly worse Oxford Hip Scores than those who did not. Mean scores for anxiety items concerning possible dislocation and durability of the implant were significantly higher in Japanese than in Chinese subjects. Our findings suggest that providing information about housing conditions and lifestyles would result in improved quality of life and reduced anxiety in patients with implanted joints. © 2014 Wiley Publishing Asia Pty Ltd.

  20. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    Science.gov (United States)

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift

  1. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  2. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  3. Automated bone segmentation from large field of view 3D MR images of the hip joint

    International Nuclear Information System (INIS)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-01-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head–neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone–cartilage interfaces for potential cartilage segmentation. (paper)

  4. Determinación del desgaste del componente acetabular en prótesis totales de cadera. // Wear determination of acetabular component in total hip prosthesis.

    Directory of Open Access Journals (Sweden)

    G. García del Pino

    2002-01-01

    Full Text Available En este trabajo se realiza un estudio a través del Método de los Elementos Finitos “MEF” sobre el desgaste del componenteacetabular durante el ciclo de marcha y considerando algunos casos extremos de cargas como subir y bajar escaleras,levantarse de una silla, etc. Utilizando el MEF fueron modelados independientemente los componentes acetabular yfemoral de la prótesis total de cadera y puestos en contacto posteriormente. Fueron estudiadas varias posiciones delacetábulo así como diferentes casos de carga simulando pacientes con diferente peso corporal y actividades físicas. Paraevaluar los resultados se crearon rutinas en lenguaje C que organizaron los mismos para un tratamiento estadísticoposterior.Palabras claves: biomecánica, ortopedia, elementos finitos, modelación, desgaste, prótesis de cadera.___________________________________________________________________________Abstract.A wear study of acetabular component during the marching cycle, considering some extreme loads cases as: ascend anddescend stairways, get up from a seat, etc , by means of Finite Elements Method ( FEM , is carried out. The acetabular andfemoral component of the total hip prosthesis were independently modeled and placed in contact lastly. Several acetabulpositions were studied as well as different load cases, simulating patients with different body weight and different physicalactivities. To evaluate the results routines in C language were created in order to organized the same ones for a laterstatistical treatment.Key words. biomechanics, ortophedy, finite elements, modelation, wear, hip bone prosthesis.

  5. Total hip arthroplasty in a patient with arthrogryphosis and an ipsilateral above knee amputation.

    LENUS (Irish Health Repository)

    Leonard, Michael

    2010-10-01

    The authors present the case of a young man with arthrogryphosis multiplex congenita and an above knee amputation who underwent an ipsilateral total hip replacement. The unique aspects of the case and technical difficulties are highlighted. Follow-up at five years revealed an excellent clinical and radiological outcome.

  6. Comparative responsiveness of measures of pain and function after total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A K; Roos, Ewa M.; Westerlund, J P

    2001-01-01

    To compare the responsiveness of the Functional Assessment System (FAS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Medical Outcomes Study 36-item Short Form (SF-36) in patients with osteoarthritis (OA) scheduled for total hip replacement....

  7. Evaluation of the Function and Quality of Life after Total Hip Arthroplasty by Different Approaches

    Directory of Open Access Journals (Sweden)

    Paulo Araújo

    2017-09-01

    Conclusion: After 24 months post total hip arthroplasty there are no differences between the two approaches with regard to function or quality of life. However, the patients operated by the anterolateral approach had greater muscle strength deficits and higher percentage of positive Trendelenburg test.

  8. Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!

    DEFF Research Database (Denmark)

    Hailer, N. P.; Lazarinis, S.; MaKela, K. T.

    2015-01-01

    Background and purpose - It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. Patients and m...

  9. Is Lumbosacral Plexus Block an Effective and Safe Alternative as Surgical Anesthesia for Total Hip Replacement?

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Larsen, Jens Rolighed; Børglum, Jens

    BACKGROUND An increasing number of patients for total hip replacement presents with cardiovascular comorbidities, that render them fragile to traditional methods of anesthesia. The aim of this intended study is to compare lumbosacral plexus blockade with continuous spinal anesthesia for surgical ...

  10. Use of Tranexamic Acid during Total Endoprosthetic Replacement of the Hip Joint

    Directory of Open Access Journals (Sweden)

    D. D. Selivanov

    2010-01-01

    Full Text Available Objective: to evaluate the blood-saving activity, efficacy, and safety of tranexamic acid. Subjects and methods. Thirty-seven patients allocated into two groups were enrolled in the study of the efficacy of tranexamic acid as an agent in reducing blood loss during hip joint replacement. Group 2 patients were injected tranexamic acid, 10 mg/kg body weight, 20—30 minutes before and 3 hours after surgery in the same dosage. This resulted in a significant (48.5% reduction in total blood loss (from 1089.6 to 560.8 ml (p<0.05. No tranexamic acid-induced complications were found. The administration of tranexamic acid during total endoprosthetic replacement of the hip joint could reduce blood loss by 35 and 59.4% in the intraoperative and postoperative periods, respectively, and total blood loss by 48.4%. The use of tranexamic acid allows one to refuse transfusion of blood components during total endoprosthetic replacement of the hip joint. Key words: hip joint replacement, blood loss, tranexamic acid.

  11. MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment

    International Nuclear Information System (INIS)

    Johnston, Ciaran; Kerr, Jennifer; Ford, Stephanie; Eustace, Stephen; O'Byrne, John

    2007-01-01

    To evaluate MRI as a problem-solving tool for patients with an unexplained failed total hip replacement following conventional radiological assessment. Patients' informed consent was obtained in all cases. Institutional review board approval was obtained. Twenty-eight patients with unexplained failed total hip replacements following conventional radiological assessment underwent additional MR imaging with an optimised turbo-spin echo sequence. Images were reviewed by two musculoskeletal radiologists by consensus and compared with findings at surgery, or following response to image-guided intervention or clinical follow-up. Of the 28 patients, MRI revealed an unsuspected diagnosis explaining the cause of prosthesis failure in 15 patients. In eight of 15 patients in this group, subsequent minimally invasive image-guided intervention obviated the need for revision total hip replacement. No cause for prosthesis failure was identified in 13 patients. MRI may be successfully undertaken in patients following total hip replacement, and, when performed, it frequently leads to an unsuspected diagnosis, allowing informed patient treatment. In this study it allowed the identification of an unsuspected diagnosis in over 50% of cases. (orig.)

  12. Patient pain and blood management in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Thomassen, Bregje J.W.

    2014-01-01

    What is already known on this topic: Local infiltration analgesia in combination with a multimodal pain approach helps for adequate postoperative pain control. Blood saving alternatives should be implemented in the process of primary total hip and knee arthroplasties. The endpoint in patient

  13. Functional exercise after total hip replacement (FEATHER): a randomised control trial.

    LENUS (Irish Health Repository)

    Monaghan, Brenda

    2012-11-01

    Prolonged physical impairments in range of movement, postural stability and walking speed are commonly reported following total hip replacement (THR). It is unclear from the current body of evidence what kind of exercises should be performed to maximize patient function and quality of life.

  14. Assessment of asymmetric leg loading before and after total hip arthroplasty using instrumented shoes

    NARCIS (Netherlands)

    Martínez-Ramírez, Alicia; Weenk, D.; Lecumberri, Pablo; Verdonschot, Nicolaas Jacobus Joseph; Pakvis, Dean; Veltink, Petrus H.

    2013-01-01

    The stance time and the average vertical ground reaction force measured with the instrumented shoes during walking, and their symmetry index, showed significant differences before and after total hip arthroplasty. However, the data obtained with the sit to stand test did not reveal this improvement

  15. Muscle Damage After Total Hip Arthroplasty Through the Direct Anterior Approach for Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Kawasaki, Masashi; Hasegawa, Yukiharu; Okura, Toshiaki; Ochiai, Satoshi; Fujibayashi, Takayoshi

    2017-08-01

    Total hip arthroplasty (THA) through the direct anterior approach (DAA) is known to cause less muscle damage than other surgical approaches. However, more complex primary cases, such as developmental dysplasia of the hip (DDH), might often cause muscle damage. The objective of the present study was to clarify the muscle damage observed 1 year after THA through the DAA for DDH using magnetic resonance imaging. We prospectively compared the muscle cross-sectional area (M-CSA) and fatty atrophy (FA) in muscles by magnetic resonance imaging and the Harris hip score before and at 1-year follow-up after THA through the DAA in 3 groups: 37 patients with Crowe group 1 DDH (D1), 13 patients with Crowe group 2 and 3 DDH (D2 + 3), and 12 patients with osteonecrosis as a control. THA through the DAA for D1 displayed significantly decreased M-CSA and significantly increased FA in the gluteus minimus (Gmini), the tensor fasciae latae (TFL), and the obturator internus (OI). Patients with D2 + 3 group did not have decreased M-CSA in the TFL or increased FA in the Gmini. Postoperatively, a significant negative correlation was observed between the M-CSA and FA for the OI in patients with D1 and D2 + 3. THA through the DAA for DDH caused the damage in the Gmini, the TFL, and the OI; severe damage was observed in the OI, showing increased FA with decreased M-CSA in patients with both D1 and D2 + 3. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

    OpenAIRE

    M Erceg; K Becic

    2014-01-01

    A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author′s knowledge, nobody has e...

  17. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis

    Directory of Open Access Journals (Sweden)

    M Erceg

    2014-01-01

    Full Text Available A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years.To the best of the author′s knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  18. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    Science.gov (United States)

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  19. Unusual way of loosened total hip arthroplasty treatment with an Austin Moore endoprosthesis.

    Science.gov (United States)

    Erceg, M; Becic, K

    2014-01-01

    A 65-year-old female patient with aseptic loosening of total cemented hip endoprosthesis and pathologic fracture of the femur at the level of the stem of endoprosthesis was presented. As no appropriate endoprosthesis was available due to the war in Croatia and war priority, the problem was managed by femur osteosynthesis and implantation of a partial Austin Moore hip endoprosthesis. The endoprosthesis is still functioning well (for 20 years).To the best of the author's knowledge, nobody has ever treated problem like this using this alternative, an unconventional method, with an Austin Moore endoprosthesis.

  20. Indications of 99mTc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties

    International Nuclear Information System (INIS)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M.; Rosset, P.

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a 99 Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  1. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Science.gov (United States)

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  2. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    International Nuclear Information System (INIS)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M.; Sivberg, B.

    2004-01-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, κ w , analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied κ w 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied κ w of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  3. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M. [Department of Radiology, Center for Medical Imaging and Physiology, Lund University Hospital, 22185, Lund (Sweden); Sivberg, B. [Department of Nursing, Faculty of Medicine, Lund University, P.O. Box 157, 22100, Lund (Sweden)

    2004-05-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, {kappa}{sub w}, analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied {kappa}{sub w} 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied {kappa}{sub w} of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  4. An animal experimental study of transient synovitis of hip using three phase bone imaging

    International Nuclear Information System (INIS)

    Liang Jiugen; Lu Bing; Lu Xiaohu; Liu Shangli

    1994-01-01

    A model of transient synovitis was established by means of injecting noradrenaline (NA) into the joint cavity of young dogs. Radionuclide three phase bone imaging was then used to observe the local blood supply of femoral head and histological examination was used to understand the natural course of the disease process. The result showed that there were transient synovitis of the hip and decrease of blood supply in the affected femoral head after NA injection, but the changes gradually returned to normal after 4 weeks. No evidence of femoral head necrosis had been noticed. It is suggested that serial quantitative analysis of three phase bone imaging may have good clinical value in the early diagnosis transient hip synovitis, as well as in the assessment of the stage of the disease etc

  5. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    Science.gov (United States)

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  6. Feasibility of Early-Initiated Progressive Resistance Training after Total Hip Replacement

    DEFF Research Database (Denmark)

    Mikkelsen, Lone Ramer; Mechlenburg, Inger; Petersen, Annemette Krintel

    during the exercises were measured at each training session. Isometric muscle strength was measured before and 4 weeks after the THR. Findings / Results: Pain during exercises and resting pain before and after each training session was unchanged or decreased during the 4 weeks of training. Averaged...... across exercises pain during training decreased from 3.6 (sd: 2.8) at the first session to 1.52 (sd: 1.8) VAS-mm at the last session, ptraining load increased progressively for all 4 exercises during the 4 weeks of training. For example: 2nd, 5th and 8th training session. Hip......Background: Muscle atrophy, reduced hip muscle strength and function are documented within the first weeks after Total Hip Replacement (THR). Purpose / Aim of Study: The purpose of this study was to evaluate the feasibility of early-initiated progressive resistance training (PRT) after THR...

  7. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    Science.gov (United States)

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Predictors of pain and physical function at 3 and 12 months after total hip arthroplasty

    DEFF Research Database (Denmark)

    Plews, Sarah; Løvlund Nielsen, Randi; Overgaard, Søren

    Background: Few studies have combined preoperative patient-reported and objective outcome measures to predict outcomes after total hip arthroplasty (THA). Purpose / Aim of Study: to identify predictors of outcome 3 and 12 months after THA Materials and Methods: A cohort of 107 consecutive patients...... with primary hip osteoarthritis responded to Hip dysfunction and Osteoarthritis Outcome Score (HOOS) questionnaires prior to and 3 and 12 months after THA. Preoperative pain intensity; joint space width (JSW), age, gender, and body mass index (BMI) were used to predict changes in pain and physical function....... Conclusions: Preoperative pain predicted changes in pain and physical function up to one year after THA. Such knowledge should be taken into consideration, when assessing OA patients prior to surgery. This study provides useful insight for clinicians, regarding the overall improvement patients can expect...

  9. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    Science.gov (United States)

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  10. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    Science.gov (United States)

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  11. Formation of a pseudotumor in total hip arthroplasty using a tribological metal-polyethylene pair

    Directory of Open Access Journals (Sweden)

    Lorenzo Fagotti

    2015-12-01

    Full Text Available ABSTRACT The aim here was to report a case of a young adult patient who evolved with tumor formation in the left thigh, 14 years after revision surgery on hip arthroplasty. Davies in 2005 made the first description of this disease in patients undergoing metal-on-metal hip arthroplasty. Over the last decade, however, pseudotumors around metal-on-polyethylene surfaces have become more prevalent. Our patient presented with increased volume of the left thigh 8 years after hip arthroplasty revision surgery. Two years before the arising of the tumor in the thigh, a nodule in the inguinal region was investigated to rule out a malignant neoplastic process, but the results were inconclusive. The main preoperative complaints were pain, functional limitation and marked reduction in the range of motion of the left hip. Plain radiographs showed loosening of acetabular and femoral, and a large mass between the muscle planes was revealed through magnetic resonance imaging of the left thigh. The surgical procedure consisted of resection of the lesion and removal of the components through lateral approach. In respect of total hip arthroplasty, pseudotumors are benign neoplasms in which the bearing surface consists of metal-on-metal, but they can also occur in different tribological pairs, as presented in this case.

  12. Diabetes and change in bone mineral density at the hip, calcaneus, spine, and radius in older women

    Directory of Open Access Journals (Sweden)

    Ann V. Schwartz

    2013-05-01

    Full Text Available Older women with type 2 diabetes mellitus (DM have higher bone mineral density (BMD but also have higher rates of fracture compared to those without DM. Limited evidence suggests that DM may also be associated with more rapid bone loss. To determine if bone loss rates differ by DM status in older women, we analyzed BMD data in the Study of Osteoporotic Fractures (SOF between 1986 and 1998. SOF participants were women >65 years at baseline who were recruited from four regions in the U.S. DM was ascertained by self-report. BMD was measured with dual x-ray absorptiometry (DXA at baseline and at least one follow-up visit at the hip (N=6624 and calcaneus (N=6700 and, on a subset of women, at the spine (N=396 and distal radius (N=306. Annualized percent change in BMD was compared by DM status, using random effects models. Of 6,867 women with at least one follow-up DXA scan, 409 had DM at baseline. Mean age was 70.8 (SD 4.7 years. Baseline BMD was higher in women with DM at all measured sites. In models adjusted for age and clinic, women with prevalent DM lost bone more rapidly than those without DM at the femoral neck (-0.96% vs. -0.59% per year, p < 0.001, total hip (-0.98% vs. -0.70% per year, p<0.001, calcaneus (-1.64% vs. -1.40% per year, p=0.005, and spine (-0.33% vs. +0.33% per year, p=0.033, but not at the distal radius (-0.97% vs. -0.90% per year, p=0.91. These findings suggest that despite higher baseline BMD, older women with DM experience more rapid bone loss than those without DM at the hip, spine and calcaneus, but not the radius. Higher rates of bone loss may partially explain higher fracture rates in older women with DM.

  13. Lunar phase does not influence perioperative complications in total hip arthroplasty.

    Science.gov (United States)

    Ficklscherer, Andreas; Angermann, Alexander; Weber, Patrick; Wegener, Bernd; Pietschmann, Matthias; Müller, Peter

    2012-02-29

    Lunar calendars, publishing recommendations for daily life, are gaining more and more attention in Germany, where 10.5% of the population believe in lunar effects on disease. A widespread and often heard belief is that a full moon has the most negative effects on surgical outcome. The present study evaluates the effects of lunar phase on perioperative complications in total hip arthroplasty. We performed a retrospective study with 305 patients being provided with a primary hip arthroplasty. To identify possible influences of the lunar phase on perioperative complications we investigated data such as operation length, blood loss and course of C-reactive protein that were collected during the patients' stay in the hospital and allocated them to moon illumination. There were no significant differences in all collected data concerning the lunar phase (p > 0.05). Although not statistically significant, there were fewer operations during the full moon phase. Therefore there is no evidence that lunar phase has an effect on perioperative complications in total hip arthroplasty. Fewer, though not significantly fewer, operations were performed during the full moon phase. Although this was not a prospective randomized trial, the statistical magnitude of the results does not support any recommendations for scheduling patients for total hip arthroplasty at any particular day of the lunar phase.

  14. Bone mineral density at the hip predicts mortality in elderly men.

    Science.gov (United States)

    Trivedi, D P; Khaw, K T

    2001-01-01

    Low bone density as assessed by calcaneal ultrasound has been associated with mortality in elderly men and women. We examined the relationship between bone density measured at the hip and all cause and cardiovascular mortality in elderly men. Men aged 65-76 years from the general community were recruited from general practices in Cambridge between 1991 and 1995. At baseline survey, data collection included health questionnaires, measures of anthropometry and cardiovascular risk factors, as well as bone mineral density (BMD) measured using dual energy X-ray absorptiometry. All men have been followed up for vital status up to December 1999. BMD was significantly inversely related to mortality from all causes and cardiovascular disease, with decreasing rates with increasing bone density quartile, and an approximate halving of risk between the bottom and top quartile (p risk (95% CI 0.66-0.91) for all-cause mortality and 0.76 relative risk (95% CI 0.62-0.93) for cardiovascular disease mortality. The association remained significant after adjusting for age, body mass index, cigarette smoking status, serum cholesterol, systolic blood pressure, past history of heart attack, stroke or cancer and other lifestyle factors which included use of alcohol, physical activity and general health status. Low bone density at the hip is thus a strong and independent predictor of all-cause and cardiovascular mortality in older men.

  15. Male Astronauts Have Greater Bone Loss and Risk of Hip Fracture Following Long Duration Spaceflights than Females

    Science.gov (United States)

    Ellman, Rachel; Sibonga, Jean; Bouxsein, Mary

    2010-01-01

    This slide presentation reviews bone loss in males and compares it to female bone loss during long duration spaceflight. The study indicates that males suffer greater bone loss than females and have a greater risk of hip fracture. Two possible reason for the greater male bone loss are that the pre-menopausal females have the estrogen protection and the greater strength of men max out the exercise equipment that provide a limited resistance to 135 kg.

  16. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  17. Surgery-induced changes and early recovery of hip-muscle strength, leg-press power, and functional performance after fast-track total hip arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Thorborg, Kristian; Husted, Henrik

    2013-01-01

    By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits.......By measuring very early changes in muscle strength and functional performance after fast-track total hip arthroplasty (THA), post-operative rehabilitation, introduced soon after surgery, can be designed to specifically target identified deficits....

  18. Clinical Outcomes of Total Hip Arthroplasty in Patients with Ankylosed Hip

    Directory of Open Access Journals (Sweden)

    Babak Siavashi

    2014-03-01

    Full Text Available Background:   Various drugs are administered intra-articularly to provide postoperative analgesia after arthroscopic knee surgery. The purpose of this study was to assess the analgesic effects of intra-articular injection of a dexmedetomidine   following knee arthroscopy.     Methods:   Forty six patients schadualed for arthroscopic knee surgery under general anaesthesia, were randomly devided into two groups. Intervention group received 1μg/kg dexmedetomidine (D and isotonic saline. Control group   received 25ml isotonic saline (P. Analgesic effects were evaluated by measuring pain intensity (VAS scores and   duration of analgesia.     Results:   There was no significant difference between the two groups in terms of age, sex and weight. The mean of post-operation pain severity in 1, 3, 6,12, and 24 h was significantly lower in the intervention group (D in comparison   with the control group (P. the mean of the total dose of tramadol consumption was significantly lower in the interven       tion group in comparison with the control group (     P

  19. Hip Injuries and Disorders

    Science.gov (United States)

    Your hip is the joint where your femur (thigh bone) meets your pelvis (hip bone). There are two main parts: a ball ... fits in a socket in the pelvis. Your hip is known as a ball-and-socket joint. ...

  20. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  1. DIFFICULTIeS OF TOTAL HIP REPLACEMENT IN PATIENTS WITH ANKYLOSING SPONDYLITIS (case report

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available A distinctive feature of patients with ankylosing spondylitis is the formation of hip ankylosis in an extremely unfavorable functional position combined with upset of sagittal balance of the body along with a thoracolumbar kyphosis. Treatment of these patients poses considerable technical difficulties and is often associated with complications. The authors report a clinical case of a female 40 years old patient with confirmed rhizomelic spondylitis. The patient mainly complained of fixed malposition of the right lower extremity (hip ankylosis in extreme 1450 flexion and 1500 abduction combined with a severe fixed spine deformity (thoracic kyphosis 920, lumbar lordosis 170. Considering significant sagittal balance disorder it was decided to go for a two-stage procedure. Total hip arthroplasty of the right joint was performed at the first stage. At the second stage the authors corrected thoracolumbar spinal deformity by Th12 (type PSO 4 and L2 (type PSO 3 wedge resections and converging resected vertebral bodies by a multilevel fixation system with transpedicular support elements. The interval between the stages was 11 months. Two-stage treatment of this patient al-lowed to avoid adverse postoperative complications and to achieve a significant functional improvement in one year after treatment started. The sum of points before and after the treat-ment amounted respectively to 46 and 79 on Harris Hip Score, 17 and 38 points on Oxford Hip Score (OHS. To summarize, comprehensive treatment with planning of all subsequent steps prior to hip replacement is the method of choice for avoidance of postoperative complications in patients with ankylosing spondylitis accompanied by a significant upset of sagittal balance.

  2. Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?

    DEFF Research Database (Denmark)

    Bandholm, Thomas; Kehlet, Henrik

    2012-01-01

    Bandholm T, Kehlet H. Physiotherapy exercise after fast-track total hip and knee arthroplasty: time for reconsideration? Major surgery, including total hip arthroplasty (THA) and total knee arthroplasty (TKA), is followed by a convalescence period, during which the loss of muscle strength......-track methodology or enhanced recovery programs. It is the nature of this methodology to systematically and scientifically optimize all perioperative care components, with the overall goal of enhancing recovery. This is also the case for the care component "physiotherapy exercise" after THA and TKA. The 2 latest...... meta-analyses on the effectiveness of physiotherapy exercise after THA and TKA generally conclude that physiotherapy exercise after THA and TKA either does not work or is not very effective. The reason for this may be that the "pill" of physiotherapy exercise typically offered after THA and TKA does...

  3. The influence of optimism on functionality after total hip replacement surgery.

    Science.gov (United States)

    Balck, Friedrich; Lippmann, Maike; Jeszenszky, Csilla; Günther, Klaus-Peter; Kirschner, Stephan

    2016-08-01

    Among other factors, optimism has been shown to significantly influence the course of some diseases (cancer, HIV, coronary heart disease). This study investigated whether optimism of a patient before a total hip replacement can predict the functionality of the lower limbs 3 and 6 months after surgery. A total of 325 patients took part in the study (age: 58.7 years; w: 55%). The functionality was measured with the Western Ontario and McMaster Universities arthrosis index, and optimism with the Life Orientation Test. To analyse the influences of age, gender and optimism, general linear models were calculated. In optimistic patients, functionality improved significantly over time. The study showed a clear influence of dispositional optimism on the recovery after total hip replacement in the first 3 months after surgery. © The Author(s) 2015.

  4. Avascular Necrosis Is Associated With Increased Transfusions and Readmission Following Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Lovecchio, Francis C; Manalo, John Paul; Demzik, Alysen; Sahota, Shawn; Beal, Matthew; Manning, David

    2017-05-01

    Avascular necrosis (AVN) may confer an increased risk of complications and readmission following total hip arthroplasty (THA). However, current risk-adjustment models do not account for AVN. A total of 1706 patients who underwent THA for AVN from 2011 to 2013 were selected from the American College of Surgeon's National Surgical Quality Improvement Program database and matched 1:1 to controls using a predetermined propensity score algorithm. Rates of 30-day medical and surgical complications, readmissions, and reoperations were compared between cohorts. Propensity-score logistic regression was used to determine independent associations between AVN and outcomes of interest. Patients with AVN had a higher rate of medical complications than those without AVN (20.3% vs 15.3%, respectively; PAvascular necrosis of the femoral head is an independent risk factor for transfusion up to 72 hours postoperatively and readmission up to 30 days following total hip replacement. [Orthopedics. 2017; 40(3):171-176.]. Copyright 2017, SLACK Incorporated.

  5. Odds ratios for hip- and lower forearm fracture using peripheral bone densitometry; a case-control study of postmenopausal women

    DEFF Research Database (Denmark)

    Saleh, M M A; Jørgensen, H L; Lauritzen, J B

    2002-01-01

    concern when using peripheral densitometry is the poor correlation with the central measurements. The main aim of this study is, therefore, to assess the possibility of expressing ultrasound measurements at the heel and bone mineral density (BMD) measured at the distal forearm as fracture odds ratios...... rather than an absolute measure of bone mass. METHODS: A total of 76 women with lower forearm fracture, 47 women with hip fracture and 231 age-matched women (controls) were included. All had broadband ultrasound attenuation (BUA) and speed of sound (SOS) measured at the heel using the DTU-one ultrasound.......8; 5.2) for heel-BUA (T-score cutoff: -2.3), 4.1 (2.3; 7.4) for heel-SOS (-2.1) and 2.2 (1.3; 3.7) for lower forearm BMD (-2.7). The odds ratio for hip fracture was 3.4 (1.5-7.7) for heel-BUA (-2.7), 3.6 (1.6; 8.1) for heel-SOS (-2.6) and 3.2 (1.4; 7.4) for lower forearm BMD (-2.9). CONCLUSION...

  6. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    Science.gov (United States)

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  7. Social profile and cost analysis of deep infection following total hip replacement surgery

    Directory of Open Access Journals (Sweden)

    Vera Lucia Frazão

    Full Text Available ABSTRACT OBJECTIVE: To characterize the socio-economic and demographic profile of patients undergoing surgery for revision total hip arthroplasty regarding the diagnosis of deep prosthetic infection. METHODS: Twenty patients were retrospectively studied, admitted in the period between 2009 and 2010 by the Hip Surgery Group with the diagnosis of deep prosthetic infection, whose proposed treatment was surgical. This study was carried out in the presence of the patient by completing two forms applied by the social worker of the Group. RESULTS: In a 20-patient sample, 40% were male, 45% were working age, 50% of patients originated from the capital, 85% depended on benefits, 70% were retired, 60% of patients were from this hospital, and 40% were from other services. The average cost of patients to the public system was R$ 55,821.62 per patient and the total spent on treatment of patients in the study exceeded one million Brazilian reals, totalling R$ 1,116,432.40. CONCLUSION: Infection from total hip arthroplasty generates a major expense to the social security system and to the public healthcare system. Physicians must always be alert to the possible risk factors and perioperative care, striving to minimize this complication.

  8. P-Selectin: An Unpredicted Factor for Deep Vein Thrombosis after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Dongquan Shi

    2014-01-01

    Full Text Available Introduction. Deep vein thrombosis (DVT is a severe complication after total hip arthroplasty (THA. It leads to acute pulmonary embolism, a life-threatening disease. P-selectin is a 140-kDa transmembrane glycoprotein. Elevated P-selectin was associated with 1.7-fold increase in the risk of venous thrombosis. Materials and Methods. To confirm the association, a total of 91 subjects who received primary total hip arthroplasty using lateral approach performed by one skilled orthopedic surgeon were studied. All the patients were consecutively enrolled at the Center of Diagnosis and Treatment for Joint Diseases, Drum Tower Hospital affiliated to the Medical School of Nanjing University from 2010 to 2012. All the subjects received venography 3–5 days after operation. We measured P-selectin by means of a highly sensitive sandwich ELISA technique and a commercially available test reagent set. Results. No significant association was detected between P-selectin and DVT (all P  values>0.05. ΔsP-selectin was correlated with weight, APTT after operation, history of DVT, and diagnosis of primary disease ( P values were 0.03, 0.03, 0.04, and 0.02, resp.. Conclusion. P-selectin may not be a predicted factor for deep vein thrombosis after total hip arthroplasty.

  9. Prevention of venous thromboembolic disease after total hip and knee arthroplasty.

    Science.gov (United States)

    Lieberman, Jay R; Hsu, Wellington K

    2005-09-01

    Patients undergoing total hip and knee arthroplasty are at increased risk for the development of venous thromboembolic disease, and there is general agreement that these patients require prophylaxis. The selection of a prophylactic agent involves a balance between efficacy and safety and often needs to be individualized for specific patients and institutions. Despite extensive research, the ideal agent for prophylaxis against deep venous thrombosis has not been identified. The results of randomized trials indicate that low-molecular-weight heparin, warfarin, and fondaparinux are the most effective prophylactic agents after total hip arthroplasty and that low-molecular-weight heparin, warfarin, fondaparinux, and pneumatic compression boots are the most effective agents after total knee arthroplasty. The duration of prophylaxis against deep venous thrombosis after total hip and knee arthroplasty remains controversial. Prophylaxis should be continued beyond hospital discharge. In the future, the determination of the duration of prophylaxis will be based on the risk stratification of individual patients. The practice of discharging patients from the hospital without prophylaxis, even when the decision is based on negative results of procedures that screen for the presence of deep venous thrombosis, is not cost-effective.

  10. The effects of the empowerment education program in older adults with total hip replacement surgery.

    Science.gov (United States)

    Huang, Tzu-Ting; Sung, Chia-Chun; Wang, Woan-Shyuan; Wang, Bi-Hwa

    2017-08-01

    To measure the effectiveness of an education empowerment program on primary (self-efficacy and self-care competence) and secondary outcomes (Activities of Daily Life, mobility, depressive mood and quality of life) for older adults with total hip replacement surgery. Degenerative arthritis is a common and serious chronic illness that impacts the quality of life of older adults. As joints continue to degenerate and the hip damaged by arthritis, activities of daily life will be difficult to perform due to severe hip pain and joint stiffness. Therefore, hip replacement surgery should be considered and effective nursing care should be provided to improve the recovery of older adults. A prospective randomized control trial. A trial was conducted from September 2013 - May 2014 in two hospitals in northern Taiwan. 108 participants were random assigned to either the education empowerment group or in the comparison group. The researchers collected baseline data at admission and outcomes on the day of discharge, one month after and three months after the discharge. After the interventions, the education empowerment group participants demonstrated significantly higher self-care competence and self-efficacy and lower depressive inclinations compared with those in the comparison group. Participants in both groups significantly improved on activities of daily life, mobility and quality of life over the course of the interventions. This education empowerment intervention was very effective in enhancing participants' outcomes. Moreover, involving both older adults and their caregivers for the participation this program is recommended for a greater impact. © 2017 John Wiley & Sons Ltd.

  11. Routine one-stage exchange for chronic infection after total hip replacement.

    Science.gov (United States)

    Jenny, Jean-Yves; Lengert, Régis; Diesinger, Yann; Gaudias, Jeannot; Boeri, Cyril; Kempf, Jean-François

    2014-12-01

    We hypothesized that a routine one-stage exchange for treatment of chronically infected total hip replacement (THR) will lead to (1) a higher rate of infection recurrence and (2) a poorer hip outcome than the published rates after two-stage exchange. Sixty-five cases have been treated consecutively with one-stage exchange. All patients have been followed for a period of three to six years or until death or infection recurrence. The five-year rate for infection recurrence was 16%. The five-year survival rate for recurrence of the index infection was 8%. Forty-two percent of the hips had a good or excellent PMA score, and 46% a good or excellent OH score. Routine one-stage exchange was not associated with a higher recurrence rate and a poorer hip function than previously published series of two-stage exchange. Therefore, there is little support to choose two-stage exchange as the routine treatment for management of chronically infected THR.

  12. Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty.

    Science.gov (United States)

    Wako, Yasushi; Nakamura, Junichi; Miura, Michiaki; Kawarai, Yuya; Sugano, Masahiko; Nawata, Kento

    2018-02-01

    The purpose of this study is to clarify interobserver and intraobserver reliabilities of the three-dimensional (3D) templating of total hip arthroplasty (THA). We selected preoperative computed tomography from 60 hips in 46 patients (14 men and 32 women) who underwent primary THA. To evaluate interobserver and intraobserver reliability, 6 orthopedic surgeons performed 3D templating twice over a 4-week interval. We investigated intraclass correlation coefficients (ICCs) and percent agreement of component size and alignment, comparing morphological differences in the hip. Reproducibility was also compared between groups with osteoarthritis (OA) and those with osteonecrosis (ON). The interobserver reliabilities for mean cup size and stem size were excellent, with ICC = 0.907 and 0.944, respectively. The value was significantly higher in the ON group than in the OA group. In the OA group, the reliability of cup size and alignment decreased in hips with severe subluxation. Percent agreement of stem size was significantly different between the shapes of femoral canal. For intraobserver reliability, the mean ICC of cup size was 0.965 overall, while the value in the ON group was significantly higher than in the OA group. The mean ICC of stem size was 0.972 overall. Computed tomography-based 3D templating showed excellent reliability for component size and alignment in THA. Deformity of the affected joint influenced the reliability of preoperative planning. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing.

  14. Computed tomography of subchondral bone and osteophytes in hip osteoarthritis: the shape of things to come?

    Science.gov (United States)

    Turmezei, Tom D; Poole, Ken E S

    2011-01-01

    Bone is a fundamental component of the disordered joint homeostasis seen in osteoarthritis, a disease that has been primarily characterized by the breakdown of articular cartilage accompanied by local bone changes and a limited degree of joint inflammation. In this review we consider the role of computed tomography imaging and computational analysis in osteoarthritis research, focusing on subchondral bone and osteophytes in the hip. We relate what is already known in this area to what could be explored through this approach in the future in relation to both clinical research trials and the underlying cellular and molecular science of osteoarthritis. We also consider how this area of research could impact on our understanding of the genetics of osteoarthritis.

  15. Computed tomography of subchondral bone and osteophytes in hip osteoarthritis: the shape of things to come?

    Directory of Open Access Journals (Sweden)

    Tom D Turmezei

    2011-12-01

    Full Text Available Bone is a fundamental component of the disordered joint homeostasis seen in osteoarthritis, a disease that has been primarily characterised by the breakdown of articular cartilage accompanied by local bone changes and a limited degree of joint inflammation. In this review we consider the role of computed tomography imaging and computational analysis in osteoarthritis research, focusing on subchondral bone and osteophytes in the hip. We relate what is already known in this area to what could be explored through this approach in the future in relation to both clinical research trials and the underlying cellular and molecular science of osteoarthritis. We also consider how this area of research could impact on our understanding of the genetics of osteoarthritis.

  16. Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip

    International Nuclear Information System (INIS)

    Hofmann, S.; Kramer, J.; Leder, K.; Neuhold, A.; Plenk, H. Jr.; Engel, A.

    1993-01-01

    In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)

  17. Correlation of MRI and histomorphological findings in bone marrow oedema syndrome of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, S [Orthopaedic University Clinic, Vienna (Austria); [Bone and Biomaterial Research Lab. of the Histology-Embryology Inst., Vienna (Austria); Kramer, J [MR Inst. of the University, Vienna (Austria); Leder, K [2. General Dept., Orthopaedic Hospital Speising, Vienna (Austria); Neuhold, A [Inst. for Imaging Diagnostics, Rudolfinerhaus Hospital, Vienna (Austria); Plenk, H Jr [Bone and Biomaterial Research Lab. of the Histology-Embryology Inst., Vienna (Austria); Engel, A [Orthopaedic University Clinic, Vienna (Austria)

    1993-10-01

    In 15 patients (16 hip joints) we found the clinical and radiological signs of BMOS. On T1-weighted MRI images areas of low signal intensity could be observed in the head, neck and the intertrochanteric region of the femur in various extensions. These areas showed a significant increase in signal intensity on the T2-weighted images. Because pain was resistant to conservative therapy all these patients were treated by core decompression of the femoral head in a prospective study. Bone cores were evaluated histologically using undecalcified sections and quantitative microradiography. The existence of intramedullary oedema in exactly the regions exhibiting the MRI pattern of bone marrow oedema was verified histologically; however, bone and marrow changes similar to those of early avascular necrosis (AVN) were also visible. (orig.)

  18. The relationship of hospital charges and volume to surgical site infection after total hip replacement.

    Science.gov (United States)

    Boas, Rebecca; Ensor, Kelsey; Qian, Edward; Hutzler, Lorraine; Slover, James; Bosco, Joseph

    2015-05-01

    The purpose of this study was to analyze the effect of hospital volume and charges on the rate of surgical site infections for total hip replacements (THRs) in New York State (NYS). In NYS, higher volume hospitals have higher charges after THR. The study team analyzed 93,620 hip replacements performed in NYS between 2008 and 2011. Hospital charges increased significantly from $43,713 in 2008 to $50,652 in 2011 (P<.01). Compared with lower volume hospitals, patients who underwent THR at the highest volume hospitals had significantly lower surgical site infection rates (P=.003) and higher total hospital charges (P<.0001). The study team found that in the highest volume hospitals, preventing one surgical site infection was associated with $1.6 million dollars in increased charges. © 2014 by the American College of Medical Quality.

  19. Cost-effectiveness of positive contrast and nuclear arthrography in patients who underwent total hip arthroplasty

    International Nuclear Information System (INIS)

    Swan, J.S.; Braunstein, E.M.; Capello, W.; Wellman, H.

    1989-01-01

    The authors have compared the cost effectiveness of contrast arthrography (CA) and nuclear arthrography (NA), in which In-111 chloride is injected with the contrast material, of total hip arthroplasties. Their series included 48 cases of surgically proved loose femoral components. The cost per true-positive result was obtained by taking the total cost of the examinations in surgically proved cases and dividing by the number of true-position cases. The cost of CA was $297 and the cost of NA was $335. For CA, the cost per true positive was $1,018, and for the NA the cost per true positive was $946. In spite of higher initial cost, NA is more cost effective than CA on a cost per true-positive case basis. NA is cost effective in evaluating hip arthroplasties in which there is suspicion of a loose femoral component

  20. The effect of education and supervised exercise vs. education alone on the time to total hip replacement in patients with severe hip osteoarthritis. A randomized clinical trial protocol.

    Science.gov (United States)

    Jensen, Carsten; Roos, Ewa M; Kjærsgaard-Andersen, Per; Overgaard, Søren

    2013-01-14

    The age- and gender-specific incidence of total hip replacement surgery has increased over the last two decades in all age groups. Recent studies indicate that non-surgical interventions are effective in reducing pain and disability, even at later stages of the disease when joint replacement is considered. We hypothesize that the time to hip replacement can be postponed in patients with severe hip osteoarthritis following participation in a patient education and supervised exercise program when compared to patients receiving patient education alone. A prospective, blinded, parallel-group multi-center trial (2 sites), with balanced randomization [1:1]. Patients with hip osteoarthritis and an indication for hip replacement surgery, aged 40 years and above, will be consecutively recruited and randomized into two treatment groups. The active treatment group will receive 3 months of supervised exercise consisting of 12 sessions of individualized, goal-based neuromuscular training, and 12 sessions of intensive resistance training plus patient education (3 sessions). The control group will receive only patient education (3 sessions). The primary end-point for assessing the effectiveness of the intervention is 12 months after baseline. However, follow-ups will also be performed once a year for at least 5 years. The primary outcome measure is the time to hip replacement surgery measured on a Kaplain-Meier survival curve from time of inclusion. Secondary outcome measures are the five subscales of the Hip disability and Osteoarthritis Outcome Score, physical activity level (UCLA activity score), and patient's global perceived effect. Other measures include pain after exercise, joint-specific adverse events, exercise adherence, general health status (EQ-5D-5L), mechanical muscle strength and performance in physical tests. A cost-effectiveness analysis will also be performed. To our knowledge, this is the first randomized clinical trial comparing a patient education plus

  1. A randomised controlled trial of total hip arthroplasty versus resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint.

    Science.gov (United States)

    Achten, Juul; Parsons, Nick R; Edlin, Richard P; Griffin, Damian R; Costa, Matthew L

    2010-01-14

    Hip replacement (arthroplasty) surgery is a highly successful treatment for patients with severe symptomatic arthritis of the hip joint. For older patients, several designs of Total Hip Arthroplasty have shown excellent results in terms of both function and value for money. However, in younger more active patients, there is approximately a 50% failure rate at 25 years for traditional implants. Hip resurfacing is a relatively new arthroplasty technique. In a recent review of the literature on resurfacing arthroplasty it was concluded that the short-term functional results appear promising but some potential early disadvantages were identified, including the risk of femoral neck fracture and collapse of the head of the femur. The aim of the current study is to assess whether there is a difference in functional hip scores at one year post-operation between Total Hip Arthroplasty and Resurfacing Arthroplasty. Secondary aims include assessment of complication rates for both procedures as well cost effectiveness. All patients medically fit for surgery and deemed suitable for a resurfacing arthroplasty are eligible to take part in this study. A randomisation sequence will be produced and administered independently. After consenting, all patients will be clinically reviewed and hip function, quality of life and physical activity level will be assessed through questionnaires. The allocated surgery will then be performed with the preferred technique of the surgeon. Six weeks post-operation hip function will be assessed and complications recorded. Three, six and 12 months post-operation hip function, quality of life and physical activity level will be assessed. Additional information about patients' out-of-pocket expenses will also be collected. Current Controlled Trials ISRCTN33354155. UKCLRN portfolio ID 4093.

  2. An Evaluation of Intra‑ and Post‑operative Blood Loss in Total Hip ...

    African Journals Online (AJOL)

    2017-05-18

    May 18, 2017 ... Results: The mean intra‑ and post‑operative blood losses were 1222.7 ... To evaluate blood loss after total hip replacement. 2. To evaluate the .... 12.3. 4.2. 0.1. Median. 400.0. 150.0. 20.0. 3.0. Mode. 400.0. 100.0. 0.0. 3.0. SD.

  3. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Lifetime risk of primary total hip replacement surgery for osteoarthritis from 2003-2013

    DEFF Research Database (Denmark)

    Ackerman, Ilana N; Bohensky, Megan A; de Steiger, Richard

    2017-01-01

    OBJECTIVE: To compare the lifetime risk of total hip replacement surgery (THR) for osteoarthritis (OA) between countries, and over time. METHODS: Data on primary THR procedures performed for OA in 2003 and 2013 were extracted from national arthroplasty registries in Australia, Denmark, Finland, N....... These multi-national risk estimates can inform resource planning for OA service delivery. This article is protected by copyright. All rights reserved....

  5. Flowtron foot-pumps for prevention of venous thromboembolism in total hip and knee replacement.

    Science.gov (United States)

    Pitto, Rocco P; Koh, Chuan K

    2015-03-01

    Mechanical prophylaxis with foot-pumps provides an interesting alternative to chemical agents in the prevention of venous thomboembolism following major orthopaedic surgery procedures. The aim of this prospective study was to assess efficacy and safety of the Flowtron(®) foot-pumps system following total hip and knee replacement. The foot pumps were used as main tool for prevention of thromboembolic events, in most cases in association with a variety of chemicals. The primary endpoint of the study was to assess the incidence of deep vein thrombosis and pulmonary embolism after total hip and knee replacement. The secondary endpoints included postoperative bleeding, swelling, bruising and wound ooze. 424 consecutive patients were included in the study. Symptomatic deep vein thrombosis was detected in 7 patients (1.6%). All symptomatic deep vein thromboses were detected after discharge before the six week follow-up clinic. Five non-fatal pulmonary embolisms occurred (1.2%). Only one patient presented a major wound bleeding (0.2%). The mean difference of swelling of thigh pre-versus postoperatively was only 22.8 mm. In conclusion, thromboembolism prophylaxis after total hip and knee replacement using Flowtron(®) foot-pumps as main prevention tool of an individualised protocol appears effective and safe. This is the first clinical report related to this popular brand of foot pumps.

  6. THE INFLUENCE OF THE SURGICAL APPROACH CONCERNING DISLOCATION IN TOTAL HIP ARTHROPLASTY.

    Science.gov (United States)

    Vicente, José Ricardo Negreiros; Pires, André Fernandes; Lee, Bruno Takasaki; Leonhardt, Marcos Camargo; Ejnisman, Leandro; Croci, Alberto Tesconi

    2009-01-01

    Our primary aim was to evaluate the occurrence of dislocation of non-cemented total hip arthroplasty, when using the posterior and the direct lateral approaches. We performed a comparative retrospective study with 232 patients submitted to non-cemented total hip arthroplasty, due to the diagnosis of primary or secondary osteoarthritis. The posterior approach was used in 105 patients while direct lateral approach was used in 127 patients. There was only one prosthesis model and the same rehabilitation program and post-operative care was used for all patients. We checked the occurrence of dislocation, the acetabular positioning and also the size of the components. There was only one case of dislocation, treated with closed reduction successfully. This was a 47 year-old female, submitted to direct lateral approach. The mean follow-up time for both groups was 23.7 months, ranging from six to 42 months. The authors conclude that the prevalence of total hip arthroplasty dislocation is similar for both approaches, and educational measures besides the use of a higher femoral offset seem to reduce the risk of this complication.

  7. Age Related Macular Degeneration and Total Hip Replacement Due to Osteoarthritis or Fracture: Melbourne Collaborative Cohort Study.

    Directory of Open Access Journals (Sweden)

    Elaine W Chong

    Full Text Available Osteoarthritis is the leading cause of total hip replacement, accounting for more than 80% of all total hip replacements. Emerging evidence suggests that osteoarthritis has a chronic inflammatory component to its pathogenesis similar to age-related macular degeneration. We evaluated the association between age-related macular degeneration and total hip replacement as proxy for severe osteoarthritis or fractured neck of femur in the Melbourne Collaborative Cohort Study. 20,744 participants had complete data on both age-related macular degeneration assessed from colour fundus photographs taken during 2003-2007 and total hip replacement. Total hip replacements due to hip osteoarthritis and fractured neck of femur during 2001-2011 were identified by linking the cohort records to the Australian Orthopedic Association National Joint Replacement Registry. Logistic regression was used to examine the association between age-related macular degeneration and risk of total hip replacement due to osteoarthritis and fracture separately, adjusted for confounders. There were 791 cases of total hip replacement for osteoarthritis and 102 cases of total hip replacement due to fractured neck of femur. After adjustment for age, sex, body mass index, smoking, and grouped country of birth, intermediate age-related macular degeneration was directly associated with total hip replacement for osteoarthritis (odds ratio 1.22, 95% CI 1.00-1.49. Late age-related macular degeneration was directly associated with total hip replacement due to fractured neck of femur (odds ratio 5.21, 95% CI2.25-12.02. The association between intermediate age-related macular degeneration and an increased 10-year incidence of total hip replacement due to osteoarthritis suggests the possibility of similar inflammatory processes underlying both chronic diseases. The association of late age-related macular degeneration with an increased 10-year incidence of total hip replacement due to fractured

  8. The Impact of Lumbar Spine Disease and Deformity on Total Hip Arthroplasty Outcomes.

    Science.gov (United States)

    Blizzard, Daniel J; Sheets, Charles Z; Seyler, Thorsten M; Penrose, Colin T; Klement, Mitchell R; Gallizzi, Michael A; Brown, Christopher R

    2017-05-01

    Concomitant spine and hip disease in patients undergoing total hip arthroplasty (THA) presents a management challenge. Degenerative lumbar spine conditions are known to decrease lumbar lordosis and limit lumbar flexion and extension, leading to altered pelvic mechanics and increased demand for hip motion. In this study, the effect of lumbar spine disease on complications after primary THA was assessed. The Medicare database was searched from 2005 to 2012 using International Classification of Diseases, Ninth Revision, procedure codes for primary THA and diagnosis codes for preoperative diagnoses of lumbosacral spondylosis, lumbar disk herniation, acquired spondylolisthesis, and degenerative disk disease. The control group consisted of all patients without a lumbar spine diagnosis who underwent THA. The risk ratios for prosthetic hip dislocation, revision THA, periprosthetic fracture, and infection were significantly higher for all 4 lumbar diseases at all time points relative to controls. The average complication risk ratios at 90 days were 1.59 for lumbosacral spondylosis, 1.62 for disk herniation, 1.65 for spondylolisthesis, and 1.53 for degenerative disk disease. The average complication risk ratios at 2 years were 1.66 for lumbosacral spondylosis, 1.73 for disk herniation, 1.65 for spondylolisthesis, and 1.59 for degenerative disk disease. Prosthetic hip dislocation was the most common complication at 2 years in all 4 spinal disease cohorts, with risk ratios ranging from 1.76 to 2.00. This study shows a significant increase in the risk of complications following THA in patients with lumbar spine disease. [Orthopedics. 2017; 40(3):e520-e525.]. Copyright 2017, SLACK Incorporated.

  9. Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.

    Science.gov (United States)

    Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J

    2017-02-01

    The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Ankylosing Spondylitis Increases Perioperative and Postoperative Complications After Total Hip Arthroplasty.

    Science.gov (United States)

    Blizzard, Daniel J; Penrose, Colin T; Sheets, Charles Z; Seyler, Thorsten M; Bolognesi, Michael P; Brown, Christopher R

    2017-08-01

    Ankylosing spondylitis (AS) is a chronic autoimmune spondyloarthropathy that primarily affects the axial spine and hips. Progressive disease leads to pronounced spinal kyphosis, positive sagittal balance, and altered biomechanics. The purpose of this study is to determine the complication profile of patients with AS undergoing total hip arthroplasty (THA). The Medicare sample was searched from 2005 to 2012 yielding 1006 patients with AS who subsequently underwent THA. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated for 90-day, 2-year, and the final postoperative follow-up for complications including hip dislocation, periprosthetic fracture, wound complication, revision THA, and postoperative infection. Compared to controls, AS patients had an RR of 2.50 (CI, 1.04-5.99) of THA component breakage at 90-days post-operatively and 1.99 (CI, 1.10-3.59) at 2-years. The RR of periprosthetic hip dislocation was elevated at 90 days (1.44; CI, 0.93-2.22) and significantly increased at 2-years (1.67; CI, 1.25-2.23) and overall follow-up (1.49; CI, 1.14-1.93). Similarly, the RR for THA revision was elevated at 90-days (1.46; CI, 0.97-2.18) and significantly increased at 2-years (1.69; CI, 1.33-2.14) and overall follow-up (1.51; CI, 1.23-1.85). Patients with AS are at increased risk for complications after THA. Altered biomechanics from a rigid, kyphotic spine place increased demand on the hip joints. The elevated perioperative and postoperative risks should be discussed preoperatively, and these patients may require increased preoperative medical optimization as well as possible changes in component selection and position to compensate for altered spinopelvic biomechanics. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Serum albumin and total lymphocyte count as predictors of outcome in hip fractures.

    LENUS (Irish Health Repository)

    O'Daly, Brendan J

    2012-02-01

    BACKGROUND & AIMS: Hip fractures are a significant cause of mortality and morbidity in the elderly. Malnutrition is a significant contributor to this, however no consensus exists as to the detection or management of this condition. We hypothesise that results of admission serum albumin and total lymphocyte count (TLC), as markers of Protein Energy Malnutrition (PEM) can help predict clinical outcome in hip fracture patients aged over 60 years. METHODS: This retrospective study evaluated the nutritional status of patients with hip fractures using albumin and TLC assays and analysed their prognostic relevance. Clinical outcome parameters studied were delay to operation, duration of in-patient stay, re-admission and in-patient, 3- and 12-month mortality. RESULTS: Four hundred and fifteen hip fracture patients were evaluated. Survival data were available for 377 patients at 12 months. In-hospital mortality for PEM patients was 9.8%, compared with 0% for patients without. Patients with PEM had a higher 12-month mortality compared to patients who had normal values of both laboratory parameters (Odds Ratio 4.6; 95% CI: 1.0-21.3). Serum albumin (Hazard Ratio 0.932, 95% CI: 0.9-1.0) and age (Hazard Ratio 1.04, 95% CI: 1.0-1.1) were found to be significant independent prognostic factors of mortality by Cox regression analysis. CONCLUSIONS: These results highlight the relevance of assessing the nutritional status of patients with hip fractures at the time of admission and emphasises the correlation between PEM and outcome in these patients.

  12. Comparison of different hip prosthesis shapes considering micro-level bone remodeling and stress-shielding criteria using three-dimensional design space topology optimization.

    Science.gov (United States)

    Boyle, Christopher; Kim, Il Yong

    2011-06-03

    Since the late 1980s, computational analysis of total hip arthroplasty (THA) prosthesis components has been completed using macro-level bone remodeling algorithms. The utilization of macro-sized elements requires apparent bone densities to predict cancellous bone strength, thereby, preventing visualization and analysis of realistic trabecular architecture. In this study, we utilized a recently developed structural optimization algorithm, design space optimization (DSO), to perform a micro-level three-dimensional finite element bone remodeling simulation on the human proximal femur pre- and post-THA. The computational simulation facilitated direct performance comparison between two commercially available prosthetic implant stems from Zimmer Inc.: the Alloclassic and the Mayo conservative. The novel micro-level approach allowed the unique ability to visualize the trabecular bone adaption post-operation and to quantify the changes in bone mineral content by region. Stress-shielding and strain energy distribution were also quantified for the immediate post-operation and the stably fixated, post-remodeling conditions. Stress-shielding was highest in the proximal region and remained unchanged post-remodeling; conversely, the mid and distal portions show large increases in stress, suggesting a distal shift in the loadpath. The Mayo design conserves bone mass, while simultaneously reducing the incidence of stress-shielding compared to the Alloclassic, revealing a key benefit of the distinctive geometry. Several important factors for stable fixation, determined in clinical evaluations from the literature, were evident in both designs: high levels of proximal bone loss and distal bone densification. The results suggest this novel computational framework can be utilized for comparative hip prosthesis shape, uniquely considering the post-operation bone remodeling as a design criterion. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Bilateral Total Hip Arthroplasty in Femoral Head Avascular Necrosis: Functional Outcomes and Complications

    Directory of Open Access Journals (Sweden)

    Afshin Taheriazam

    2016-06-01

    Full Text Available Total hip arthroplasty (THA is one of the successful and cost-benefit surgical treatments. One-stage bilateral THA (BTHA offers many benefits. However, there are concerns about the safety of the procedure and higher complications. We aimed to evaluate the complications and outcomes of one-stage BTHA with Hardinge approach for femoral head avascular necrosis patients. A total of 60 patients from April 2009 and May 2013, were underwent one-stage bilateral total hip arthroplasty (BTHA in Milad and Erfan hospitals, Tehran, Iran. A prospective analysis of the functional outcomes and complications of one-stage BTHA through Hardinge approach in patients with femoral head avascular necrosis (AVN performed. We evaluated all patients clinically and radiologically with serial follow-ups. A clinical hip score based upon the modified Harris Hip Score (MHHS was performed preoperatively and again postoperatively. During period of study 44 men (73.3% and 16 women (26.6% with a mean age of 31.40±4.08 years (range 25 to 36 years at the time of presentation were entered. The mean surgical time was 2.6±0.38 hrs. The mean hospital stay was 3 .50±0.72 days. Hemoglobin level decreased significa ntly after operation (P= 0.046. There was no reported patient with perioperative death, deep venous thrombosis, pulmonary embolism, infection, dislocation, periprosthetic fracture or heterotrophic ossification. The mean preoperative MHHS score was 47.93±7.33 in patients. MHHS score i mproved to 95.06±3.47 in the last follow-up (P=0.0001.Our results recommend the use of one-stage BTHA through Hardinge approach in femoral head avascular necrosis patients.

  14. Prevalence of radiographic hip osteoarthritis is increased in high bone mass.

    Science.gov (United States)

    Hardcastle, S A; Dieppe, P; Gregson, C L; Hunter, D; Thomas, G E R; Arden, N K; Spector, T D; Hart, D J; Laugharne, M J; Clague, G A; Edwards, M H; Dennison, E M; Cooper, C; Williams, M; Davey Smith, G; Tobias, J H

    2014-08-01

    Epidemiological studies have shown an association between increased bone mineral density (BMD) and osteoarthritis (OA), but whether this represents cause or effect remains unclear. In this study, we used a novel approach to investigate this question, determining whether individuals with High Bone Mass (HBM) have a higher prevalence of radiographic hip OA compared with controls. HBM cases came from the UK-based HBM study: HBM was defined by BMD Z-score. Unaffected relatives of index cases were recruited as family controls. Age-stratified random sampling was used to select further population controls from the Chingford and Hertfordshire cohort studies. Pelvic radiographs were pooled and assessed by a single observer blinded to case-control status. Analyses used logistic regression, adjusted for age, gender and body mass index (BMI). 530 HBM hips in 272 cases (mean age 62.9 years, 74% female) and 1702 control hips in 863 controls (mean age 64.8 years, 84% female) were analysed. The prevalence of radiographic OA, defined as Croft score ≥3, was higher in cases compared with controls (20.0% vs 13.6%), with adjusted odds ratio (OR) [95% CI] 1.52 [1.09, 2.11], P = 0.013. Osteophytes (OR 2.12 [1.61, 2.79], P subchondral sclerosis (OR 2.78 [1.49, 5.18], P = 0.001) were more prevalent in cases. However, no difference in the prevalence of joint space narrowing (JSN) was seen (OR 0.97 [0.72, 1.33], P = 0.869). An increased prevalence of radiographic hip OA and osteophytosis was observed in HBM cases compared with controls, in keeping with a positive association between HBM and OA and suggesting that OA in HBM has a hypertrophic phenotype. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Role of the greater sciatic notch of the hip bone in sexual dimorphism: a morphometric study of the north Indian population.

    Science.gov (United States)

    G, Kalsey; R K, Singla; K, Sachdeva

    2011-04-01

    The distinctive morphology and sexual dimorphism of the human hip bone makes it of interest from the anatomical, anthropological and forensic points of view. The shape of the greater sciatic notch has attracted great attention in the past. In the current investigation, an attempt has been made to find the baseline data of various parameters pertaining to the greater sciatic notch of 100 hip bones of known sex (male:female = 80:20) and side (right:left = 50:50), obtained from the Department of Anatomy, Government Medical College, Amritsar, Punjab, India, during the period 2007-2009. Seven parameters of the notch, viz. width, depth, posterior segment width, total angle, posterior segment angle, index I and index II of the greater sciatic notch were studied. The results thus obtained were compiled, tabulated, statistically analysed and were compared with the accessible literature. Out of all the parameters studied, width of the notch, posterior segment width, total angle, posterior segment angle and index II of notch were found to be significantly greater in women as compared with men. Thus the greater sciatic notch can serve as a reliable sex indicator even when the complete hip bone has not been well preserved.

  16. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty?

    Science.gov (United States)

    Müller, M; Abdel, M P; Wassilew, G I; Duda, G; Perka, C

    2015-12-01

    The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck-shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck-shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes. In total, 44 patients (mean age 65.3 years (standard deviation (SD) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (SD 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck-shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes. The mean pre-operative neck-shaft angle was significantly increased by 2.8° from 128° (SD 6.2; 119° to 147°) to 131° (SD 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (SD 8; 7.9 to 39.1) and reduced to 7.4° (SD 7.3; -11.6° to 25.9°) post-operatively (p shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck-shaft angles, but without any impact on clinical outcome. ©2015 The British Editorial Society of Bone & Joint Surgery.

  17. Bone scintigraphy as a process control with hemi-alloarthroplasty of the hip joint

    International Nuclear Information System (INIS)

    Shaltout, E.E.D.

    1983-01-01

    For the diagnostic of prosthesis complications in the treatment of femur fractures near the hip joint ('intermediate prostheses') 216 skeletal scintigrams with 99mTc MDP were made of 143 patients from 1977 to 1982, partially retrospective and partially prospective. The evaluation of the photoscan was achieved visually and photodensitometrically and divided into 10 intensity levels with the following results: 1. Increased activity concentration in the acetabulum is pathological (activated arthrosis); 2. Increased activity concentration-temporary or also continuous - in the trochanter region is pathological (loosening process); 3. Non-pathological metabolic activity as a result of the bone healing process may last longer than 1 year postoperatively; 4. Heterotopic ossification, non-fixed bone fragments and pseudoarthrosis cause continuous or newly appearing concentrations; 5. Skeletal scintigraphy is an important supplement to radiological diagnostic and a sensitive method for the recognition of metabolic activities in bone. It is recommended for progress control after hemi-alloarthrosculpture of the hip joint. (orig./TRV) [de

  18. Anterior greater trochanteric muscle pedicle bone grafting: a viable graft option adjunct to hip osteotomy or fracture surgery.

    Science.gov (United States)

    Limpaphayom, Noppachart; Osateerakun, Phatcharapa; Wilairatana, Vajara; Prasongchin, Pairatch

    2017-05-12

    The objectives were to evaluate a technique, outcome and complications following anterior greater trochanteric with gluteus medius muscle pedicle bone graft (AMG) procedure in the treatment of adolescent and active adult hip disorders. 20 patients (20 hips) with a mean age of 22.7 ± 15.6 (range 10.0-63.5) years who had undergone AMG and been followed up more than 12 months postoperative were retrospectively enrolled in our study. The AMG procedure was performed in conjunction with subcapital osteotomy for slipped capital femoral epiphysis in 12 and open reduction for fracture/dislocation in 8 hips. At the most recent evaluation, patient functional status was rated by the Harris Hip Score (HHS) and radiographic changes were graded according to Tönnis criteria. Complications were defined as Tönnis grade >2 or hip requiring further surgery. Univariate analysis was used to explore factors associated with complications. Spearman's rank correlation coefficient was calculated between HHS and Tönnis grading. At mean follow-up of 4.4 ± 2.6 (range 1.1-9.5) years, mean HHS was 87.4. Tönnis grading was rated as 0 in 10 hips, 1 in 5 hips, 2 in 2 hips, and 3 in 3 hips. Avascular necrosis of the femoral head as a complication developed in 3 hips (15%). Clinical parameters including age at surgery, duration of follow-up and diagnosis were not significantly associated with postoperative complications. A negative correlation between HHS and Tönnis grade was shown by Spearman's rank correlation (rs = -0.49, p = 0.03). The AMG can be safely recommended as an adjunct bone graft procedure when performing anterior open reduction of adolescent and active adult hip disorders.

  19. When is it safe to resume driving after total hip and total knee arthroplasty? a meta-analysis of literature on post-operative brake reaction times.

    Science.gov (United States)

    van der Velden, C A; Tolk, J J; Janssen, R P A; Reijman, M

    2017-05-01

    The aim of this study was to assess the current available evidence about when patients might resume driving after elective, primary total hip (THA) or total knee arthroplasty (TKA) undertaken for osteoarthritis (OA). In February 2016, EMBASE, MEDLINE, Web of Science, Scopus, Cochrane, PubMed Publisher, CINAHL, EBSCO and Google Scholar were searched for clinical studies reporting on 'THA', 'TKA', 'car driving', 'reaction time' and 'brake response time'. Two researchers (CAV and JJT) independently screened the titles and abstracts for eligibility and assessed the risk of bias. Both fixed and random effects were used to pool data and calculate mean differences (MD) and 95% confidence intervals (CI) between pre- and post-operative total brake response time (TBRT). A total of 19 studies were included. The assessment of the risk of bias showed that one study was at high risk, six studies at moderate risk and 12 studies at low risk. Meta-analysis of TBRT showed a MD decrease of 25.54 ms (95% CI -32.02 to 83.09) two weeks after right-sided THA, and of 18.19 ms (95% CI -6.13 to 42.50) four weeks after a right-sided TKA, when compared with the pre-operative value. The TBRT returned to baseline two weeks after a right-sided THA and four weeks after a right-sided TKA. These results may serve as guidelines for orthopaedic surgeons when advising patients when to resume driving. However, the advice should be individualised. Cite this article: Bone Joint J 2017;99-B:566-76. ©2017 The British Editorial Society of Bone & Joint Surgery.

  20. Age and Early Revision After Primary Total Hip Arthroplasty for Osteoarthritis.

    Science.gov (United States)

    Meyer, Zachary; Baca, Geneva; Rames, Richard; Barrack, Robert; Clohisy, John; Nam, Denis

    2017-11-01

    Prior reports have noted an increased risk of early revision among younger patients undergoing total hip arthroplasty (THA) but have been confounded by the inclusion of various diagnoses. The purpose of this study was to assess the revision rate and the time to revision for patients undergoing THA for osteoarthritis based on age. Patients with a diagnosis of osteoarthritis who underwent both primary and revision THA at the same institution were identified. The time between primary and revision surgery and the indication for revision were collected. Patients were stratified into 2 groups based on age at the time of primary THA: 64 years or younger (group 1) or 65 years or older (group 2). Between 1996 and 2016, a total of 4662 patients (5543 hips) underwent primary THA for a diagnosis of osteoarthritis. Of these, 100 patients (104 hips) received a revision THA (62 in group 1 and 42 in group 2). Mean age was 52.7±8.4 years in group 1 vs 73.4±6.3 years in group 2 (Pprimary to revision surgery was 3.0±3.2 years for group 1 and 1.1±2.1 years for group 2 (P=.001). Among patients undergoing primary THA for a diagnosis of osteoarthritis, younger age is not associated with an increased rate of early failure or revision. [Orthopedics. 2017; 40(6):e1069-e1073.]. Copyright 2017, SLACK Incorporated.

  1. Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.

    Science.gov (United States)

    Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M

    To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (Ptranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    Science.gov (United States)

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  3. Total Hip Arthroplasty Loosening Due to Mycobacterium Tuberculosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2017-04-01

    Full Text Available Context: Prosthetic joint infection due to Mycobacterium tuberculosis with no previous history of pulmonary or extra pulmonary tuberculosis is an extremely rare complication. Aims To report the case of a patient with tuberculous mycobacterial prosthetic hip infection, 14 years after surgery for post traumatic osteoarthritis, with no previous history of tuberculosis. Methods A 46-year-old male presented an acetabular loosening of a cemented total hip arthroplasty with subnormal biologic parameters. A one stage revision surgery was planned. Intraoperative findings suggested mycobacterial tuberculous infection with presence of periacetabular yellowish rice-shaped granules. Results A one-stage prosthesis exchange was performed; Culture on Löwenstein-Jensen medium grew MTB days after inoculation and histological examination confirmed tuberculous infection. Patient was treated by antituberculous agents for 12 months with optimal clinical and biological response and no prosthetic loosening signs at eighteen months follow up. Conclusions Total hip arthroplasty loosening due to mycobacterium tuberculosis is a rare entity, which should be evoked even when no inflammatory signs are shown. Discovery of yellowish rice-shaped granules is an indicator to investigate for tuberculosis. Management of prosthetic joint infection due to M.tuberculosis must involve both medical and surgical approach.

  4. Multimodal perioperative care plus immunonutrition versus traditional care in total hip arthroplasty: a randomized pilot study.

    Science.gov (United States)

    Alito, Miguel Aprelino; de Aguilar-Nascimento, José Eduardo

    2016-04-02

    Multimodal protocols of perioperative care may enhance postoperative recovery. However, limited information is available on preoperative immune and carbohydrate (CHO)-enriched drinks in patients undergoing hip arthroplasty. We aimed to investigate the effect of a multimodal protocol (ACERTO protocol) plus preoperative immune nutrition on the length of stay (LOS) and the postoperative acute phase response of patients undergoing total hip arthroplasty. Thirty-two patients (mean age, 58 years; range, 26-85 years; 16 males) were randomized to receive either the ACERTO protocol (n = 15, ACERTO Group), which consisted of 6 h preoperative fasting for solids, an oral drink (200 mL of 12.5 % maltodextrin) up to 2 h before induction of anesthesia, restricted intravenous fluids (only 1000 mL of crystalloid fluid after surgery) and preoperative immune nutrition (600 mL/day of Impact - Nestlé, Brazil) for five days prior to surgery, or traditional care (n = 17; control group), which consisted of 6-8 h preoperative fasting, intravenous hydration until the 1(st) postoperative day and no preoperative immune supplementation. The main endpoint was LOS. C-reactive protein (CRP) was the secondary endpoint and was assessed during induction of anesthesia and on postoperative day 2. Neither deaths nor postoperative complications occurred. The median LOS was 3 (2-5) days in the ACERTO group and 6 (3-8) days in controls (P care plus preoperative immune nutrition may decrease LOS and postoperative CRP levels in total hip arthroplasty. NCT02580214.

  5. Bone Parameters and Risk of Hip and Femur Fractures in Patients on Hemodialysis

    Science.gov (United States)

    Hazzan, Azzour D.; Jhaveri, Kenar D.; Ma, Lin; Lacson, Eduardo

    2016-01-01

    Background and objectives Patients on hemodialysis have a high rate of hip fractures. In this study, we performed a contemporary analysis of mineral and bone parameters and their relationship to hip and femur fracture risk. Design, setting, participants, & measurements Patients on hemodialysis treated between 2000 and 2013 in Fresenius Medical Care North America facilities were included. Predictors were on the basis of data as of December 31 of each baseline year and time-averaged values of selected laboratory parameters and medication doses throughout the year. Four period cohorts were constructed from baseline years: 2000, 2003, 2006, and 2009. Follow-up for each cohort was ≤3 years. Results The incidence of hip and femur fractures remained generally unchanged (P=0.40), except among patients who were white and >65 years of age, in whom the rate decreased significantly over the 14-year period (P<0.01). Results from combined multivariable models indicated that the lowest quartiles of time–averaged intact parathyroid hormone were independently associated with higher hip fracture risk (intact parathyroid hormone =181–272 pg/ml: hazard ratio, 1.20; 95% confidence interval [95% CI], 1.03 to 1.41 and intact parathyroid hormone <181 pg/ml: hazard ratio, 1.20; 95% CI, 1.01 to 1.44; referent third quartile, 273 to <433 pg/ml). The lowest quartile of time–averaged serum calcium was also associated with higher risk (calcium <8.7 mg/dl; hazard ratio, 1.17; 95% CI, 1.00 to 1.37) compared with the referent third quartile of 9.1 to <9.5 mg/dl. Conclusions We found an association between lower levels of intact parathyroid hormone and serum calcium and greater risk for hip and femur fractures among patients on hemodialysis. These findings support additional research toward elucidating long-term safety of treatment approaches for hyperparathyroidism in patients with ESRD. PMID:27026521

  6. Resource use and costs associated with opioid-induced constipation following total hip or total knee replacement surgery

    Directory of Open Access Journals (Sweden)

    Wittbrodt ET

    2018-05-01

    Full Text Available Eric T Wittbrodt,1 Tong J Gan,2 Catherine Datto,1 Charles McLeskey,1 Meenal Sinha3 1US Medical Affairs, AstraZeneca, Wilmington, DE, USA; 2Department of Anesthesiology, Stony Brook Medicine, Stony Brook, NY, USA; 3Premier Applied Sciences, Premier, Inc., Charlotte, NC, USA Purpose: Constipation is a well-known complication of surgery that can be exacerbated by opioid analgesics. This study evaluated resource utilization and costs associated with opioid-induced constipation (OIC. Patients and methods: This retrospective, observational, and propensity-matched cohort study utilized the Premier Healthcare Database. The study included adults ≥18 years of age undergoing total hip or total knee replacement as inpatients who received an opioid analgesic and were discharged between January 1, 2012, and June 30, 2015. Diagnosis codes identified patients with OIC who were then matched 1:1 to patients without OIC. Generalized linear and logistic regression models were used to compare inpatient resource utilization, total hospital costs, inpatient mortality, and 30-day all-cause readmissions and emergency department visits. Results: Of 788,448 eligible patients, 40,891 (5.2% had OIC. Covariates were well balanced between matched patients with and without OIC (n=40,890 each. In adjusted analyses, patients with OIC had longer hospital lengths of stay (3.6 versus 3.3 days; p<0.001, higher total hospital costs (US$17,479 versus US$16,265; p<0.001, greater risk of intensive care unit admission (odds ratio [OR]=1.12, 95% CI: 1.01–1.24, and increased likelihood of 30-day hospital readmissions (OR=1.16, 95% CI: 1.11–1.22 and emergency department visits (OR=1.38, 95% CI: 1.07–1.79 than patients without OIC. No statistically significant difference was found with inpatient mortality (OR=0.89, 95% CI: 0.59–1.35. Conclusion: OIC was associated with greater resource utilization and hospital costs for patients undergoing primarily elective total hip or total knee

  7. Dislocation of primary total hip arthroplasty and the risk of redislocation.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2012-09-01

    6554 primary total hip arthroplasties were reviewed. Risk factors for dislocation were analysed to assess which were important in terms of predicting recurrent instability. The patients risk of having a second dislocation was independently associated with the surgical approach adopted (p = 0.03) and the time to first dislocation from the primary hip replacement (p = 0.002). Early dislocators whose surgery was performed through an anterolateral approach had less recurrence than late dislocators through a posterior or transtrochanteric approach. None of the other risk factors including head size (p = 0.59), modularity (p = 0.54), mechanism of dislocation (p = 0.23), leg length discrepancy (p = 0.69) and acetabular inclination (p = 0.31) were influential. The use of an abduction brace was not useful in preventing a further dislocation with 69.2% of those braced re-dislocating compared to 68.5% who were not braced (p = 0.96).

  8. Trochanteric bursitis after total hip arthroplasty: incidence and evaluation of response to treatment.

    Science.gov (United States)

    Farmer, Kevin W; Jones, Lynne C; Brownson, Kirstyn E; Khanuja, Harpal S; Hungerford, Marc W

    2010-02-01

    We examined the efficacy of corticosteroid injection as treatment for postarthroplasty trochanteric bursitis and the risk factors for failure of nonoperative treatment. There were 32 (4.6%) cases of postsurgical trochanteric bursitis in 689 primary total hip arthroplasties. Of the 25 hips with follow-up, 11 (45%) required multiple injections. Symptoms resolved in 20 (80%) but persisted in 5. We found no statistically significant differences between patients who did and did not develop trochanteric bursitis, or between those who did and did not respond to treatment. There was a trend toward younger age and greater limb-length discrepancy in nonresponders. In conclusion, (1) corticosteroid injection(s) for postoperative trochanteric bursitis is effective; and (2) nonoperative management may be more likely to fail in young patients and those with leg-length discrepancy. 2010 Elsevier Inc. All rights reserved.

  9. Description of load progression and pain response during progressive resistance training early after total hip arthroplasty

    DEFF Research Database (Denmark)

    Mikkelsen, Lone R; Petersen, Annemette K; Mechlenburg, Inger

    2016-01-01

    events during the initial four weeks of training. RESULTS: The majority of patients experienced only moderate hip pain during exercise (range in median across exercises and sessions: 5-35 mm Visual Analog Scale) and mild pain at rest (median: 1-18 mm Visual Analog Scale), both of which decreased over...... time ( p training load (67%-166 % across exercises, p training sessions, short term pain response (an increase >20 mm Visual Analog Scale) occurred in 13 patients in 24 training sessions. CONCLUSION: Progressive resistance......OBJECTIVE: To describe a progressive resistance training intervention implemented shortly after total hip arthroplasty, including a detailed description of load progression, pain response and adverse events to the training. DESIGN: Secondary analyses of data from the intervention group...

  10. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  11. Fast track in total hip and knee arthroplasty--experiences from Hvidovre University Hospital, Denmark

    DEFF Research Database (Denmark)

    Husted, Henrik; Holm, Gitte

    2006-01-01

    This study investigated whether unselected patients operated on with total hip arthroplasty (THA) or total knee arthroplasty (TKA) could accomplish a self-developed accelerated track, ANORAK-HH, with a planned length of stay (LOS) of maximum 5 days and patient satisfaction at all parts of the track...... and a planned LOS of maximum 5 days. 22 patient characteristics and 11 satisfaction parameters were registered as well as readmissions within 3 months. 95% of patients had a LOS of maximum 5 days with a mean of 3.9 days. Median and mean values of satisfaction for the entire track were 10 and 9.4 out of 10...

  12. Bone marrow edema of the femoral head and transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    Berg, Bruno C. van de; Lecouvet, Frederic E.; Koutaissoff, Sophie; Simoni, Paolo; Malghem, Jacques

    2008-01-01

    The current article of this issue aims at defining the generic term of bone marrow edema of the femoral head as seen at MR imaging. It must be kept in mind that this syndrome should be regarded, not as a specific diagnosis, but rather as a sign of an ongoing abnormal process that involves the femoral head and/or the hip joint. We aim at emphasizing the role of the radiologists in making a specific diagnosis, starting from a non-specific finding on T1-weighted images and by focusing on ancillary findings on T2-weighted SE or fat-saturated proton-density weighted MR images

  13. The use of allograft bone in reconstruction of the acetabulum during hip revision arthroplasty

    International Nuclear Information System (INIS)

    David, A.; Morgan, F.; Imran Ilyas

    1999-01-01

    We have reviewed 80 patients who underwent an allograft acetabular reconstruction between 1987 and 1995. This group had a mean age of 66 years with a mean follow-up of 5.2 years. A mean preoperative Harris hip score of 32 points was improved to a mean postoperative score of 72 points. There was a 16.5% rerevision rate. Acetabular defects were classified according to the American Academy of Orthopaedic Surgeons system. Subgroup classification categories were analysed and reconstruction methodologies have been devised. This paper deals with the relative indications for the use of morsellised bone, block allografts, anatomic specific allografts and reconstruction shells according to type of acetabular defects

  14. Total hip arthroplasty by the direct anterior approach using a neck-preserving stem: Safety, efficacy and learning curve

    Directory of Open Access Journals (Sweden)

    Aditya Khemka

    2018-01-01

    Full Text Available Background: The concept of femoral neck preservation in total hip replacement (THR was introduced in 1993. It is postulated that retaining cortical bone of the femoral neck offers triplanar stability, uniform stress distribution, and accommodates physiological anteversion. However, data on safety, efficacy and learning curve are lacking. Materials and Methods: We prospectively assessed all patients who were operated for a THR with a short neck preserving stem (MiniHip between 2012 and 2014. The safety and learning curve were assessed by recording operative time; stem size; and adverse events including periprosthetic fracture; paresthesia; and limb length discrepancy (LLD. The cohort was divided into equal groups to assess the learning curve effect, and the cumulative sums (CUSUM test was performed to monitor intraoperative neck fractures. For assessment of efficacy, Oxford Hip Score (OHS and Short Form-36 (SF-36 scores were compared preoperatively and postoperatively. Results: 138 patients with median age 62 years (range 35–82 years were included with a median followup of 42 months (range 30–56 months. The minimum followup was 2.5 years. The OHS, SF-36 (physical and mental component scores improved by a mean score of 26, 28, and 27 points, respectively. All patients had LLD of <10 mm (1.9 mm ± 1.3. Adverse events included intraoperative neck fracture (n = 6, subsidence (n = 1, periprosthetic fracture (n = 1, paresthesia (n = 12, and trochanteric bursitis (n = 2. After early modification of the technique to use a smaller finishing broach, the CUSUM test demonstrated acceptable intraoperative neck fracture risk. The second surgery group had a reduced risk of intraoperative neck fracture (5/69 vs. 1/69 P = 0.2, reduced operative time (66 vs. 61 min, P = 0.06, and increased stem size (5 vs. 6, P = 0.09 although these differences were not statistically significant. Conclusions: The MiniHip stem is safe alternative to standard THR with good

  15. Incidence of perioperative complications in total hip and knee arthroplasty in patients with Parkinson disease.

    Science.gov (United States)

    Sharma, Tankamani; Hönle, Wolfgang; Handschu, René; Adler, Werner; Goyal, Tarun; Schuh, Alexander

    2018-06-01

    The aim of this study is to evaluate the difference in perioperative complication rate in total hip, bipolar hemiarthroplasties and total knee arthroplasty in patients with Parkinson disease in trauma and elective surgery in our Musculoskeletal Center during a period of 10 years. Between 2006 and 2016, 45 bipolar hemiarthroplasties in trauma surgery, 15 total knee and 19 total hip arthroplasties in patients with Parkinson's disease were performed. We divided the patients in two groups. Group I included trauma cases (45) and group II elective surgery cases (34). Complications were documented and divided into local minor and major complications and general minor and major complications. Fisher's exact test was used for statistical evaluation. In both groups, there was one local major complication (p > 0.05): In group I, there was one case of loosening of a K-wire which was removed operatively. In group II, there was one severe intraarticular bleeding requiring puncture of the hematoma. In group I, there were 38 general complications; in group II, there were 17 general complications. There was no statistical difference in complication rate (p > 0.05). Total hip arthroplasty, bipolar hemiarthroplasties and knee arthroplasty in patients with Parkinson disease is possible in elective and trauma surgery. Complication rate is higher in comparison with patients not suffering from Parkinson disease, but there is no difference in complication rate in elective and trauma surgery. Nevertheless, early perioperative neurological consultation in patients with Parkinson disease is recommended to minimize complications and improve early outcomes after arthroplasty.

  16. Simulation of the mechanical behavior of a HIP implant. Implant fixed to bone by cementation under arbitrary load

    Science.gov (United States)

    Oldani, C. R.; Dominguez, A. A.

    2007-11-01

    In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.

  17. Simulation of the mechanical behavior of a HIP implant. Implant fixed to bone by cementation under arbitrary load

    Energy Technology Data Exchange (ETDEWEB)

    Oldani, C R [Materials Department - FCEFyN - Universidad Nacional de Cordoba, Av.Velez Sarsfield 1611 (5016) Cordoba (Argentina); Dominguez, A A [INTI Cordoba, Av. Velez Sarsfield 1561 (5016) Cordoba (Argentina)

    2007-11-15

    In a previous work a finite elements model was constructed to simulate a fatigue assay according to the norm IRAM 9422-3. Three materials were studied, two of them are the most used in this type of implant (Stainless steel 3161 and alloy T16A14V) and the third was a new developed titanium alloy (Ti35Nb7Zr5Ta). Static loads were applied to the model according to the highest requirements of the norm and the stress - strain distribution were determined. In this study a simplified analysis of the material's fatigue was done according to the previous work. The best behavior of the titanium alloys vs. the stainless steel was evident. With the objective of studying the behavior of both: the implant and the femur bone, new finite elements models were realized, in which the presence of the bone was considered. Inside the bone, the femoral component of the implant was placed in a similar way of a cemented prosthesis in a total hip arthroplasty. The advantage of the titanium implant related to the stainless steel one, was very clear.

  18. Optimization the initial weights of artificial neural networks via genetic algorithm applied to hip bone fracture prediction

    OpenAIRE

    Chang, Y-T; Lin, J; Shieh, J-S; Abbod, MF

    2012-01-01

    This paper aims to find the optimal set of initial weights to enhance the accuracy of artificial neural networks (ANNs) by using genetic algorithms (GA). The sample in this study included 228 patients with first low-trauma hip fracture and 215 patients without hip fracture, both of them were interviewed with 78 questions. We used logistic regression to select 5 important factors (i.e., bone mineral density, experience of fracture, average hand grip strength, intake of coffee, and peak expirat...

  19. Long-term Outcome of Unconstrained Primary Total Hip Arthroplasty in Ipsilateral Residual Poliomyelitis.

    Science.gov (United States)

    Buttaro, Martín A; Slullitel, Pablo A; García Mansilla, Agustín M; Carlucci, Sofía; Comba, Fernando M; Zanotti, Gerardo; Piccaluga, Francisco

    2017-03-01

    Incapacitating articular sequelae in the hip joint have been described for patients with late effects of poliomyelitis. In these patients, total hip arthroplasty (THA) has been associated with a substantial rate of dislocation. This study was conducted to evaluate the long-term clinical and radiologic outcomes of unconstrained THA in this specific group of patients. The study included 6 patients with ipsilateral polio who underwent primary THA between 1985 and 2006. Patients with polio who underwent THA on the nonparalytic limb were excluded. Mean follow-up was 119.5 months (minimum, 84 months). Clinical outcomes were evaluated with the modified Harris Hip Score (mHHS) and the visual analog scale (VAS) pain score. Radiographs were examined to identify the cause of complications and determine the need for revision surgery. All patients showed significantly better functional results when preoperative and postoperative mHHS (67.58 vs 87.33, respectively; P=.002) and VAS pain score (7.66 vs 2, respectively; P=.0003) were compared. Although 2 cases of instability were diagnosed, only 1 patient needed acetabular revision as a result of component malpositioning. None of the patients had component loosening, osteolysis, or infection. Unconstrained THA in the affected limb of patients with poliomyelitis showed favorable long-term clinical results, with improved function and pain relief. Nevertheless, instability may be a more frequent complication in this group of patients compared with the general population. [Orthopedics. 2017; 40(2):e255-e261.]. Copyright 2016, SLACK Incorporated.

  20. Do large heads enhance stability and restore native anatomy in primary total hip arthroplasty?

    Science.gov (United States)

    Lombardi, Adolph V; Skeels, Michael D; Berend, Keith R; Adams, Joanne B; Franchi, Orlando J

    2011-06-01

    Dislocation remains a serious complication in hip arthroplasty. Resurfacing proponents tout anatomic femoral head restoration as an advantage over total hip arthroplasty. However, advances in bearings have expanded prosthetic head options from traditional sizes of 22, 26, 28, and 32 mm to diameters as large as 60 mm. Large heads reportedly enhance stability owing to increased range of motion before impingement and increased jump distance to subluxation. Available larger diameter material combinations include metal- or ceramic-on-highly crosslinked polyethylene and metal-on-metal, each with distinct advantages and disadvantages. We sought to determine (1) if using larger diameter heads has lowered our dislocation rate; and (2) how closely an anatomic metal-on-metal bearing with diameters to 60 mm replicates native femoral head size. We retrospectively reviewed 2020 primary arthroplasties performed with large heads (≥ 36 mm) in 1748 patients and noted dislocation incidence. In a prospective subset of 89 cases using anatomic heads, native femoral head diameter was measured intraoperatively with calipers by an independent observer and later compared with implanted size. One dislocation has occurred in 2020 hips for an incidence of 0.05%. The prosthetic head averaged 0.7 mm larger than the native head with 68 of 89 (76%) reconstructed to within ± 2 mm of native size. Larger diameter heads have contributed to lower dislocation rates and large-diameter metal-on-metal articulation can provide close anatomic restoration in primary THA.

  1. Using a calliper to restore the centre of the femoral head during total hip replacement.

    Science.gov (United States)

    Hill, J C; Archbold, H A P; Diamond, O J; Orr, J F; Jaramaz, B; Beverland, D E

    2012-11-01

    Restoration of leg length and offset is an important goal in total hip replacement. This paper reports a calliper-based technique to help achieve these goals by restoring the location of the centre of the femoral head. This was validated first by using a co-ordinate measuring machine to see how closely the calliper technique could record and restore the centre of the femoral head when simulating hip replacement on Sawbone femur, and secondly by using CT in patients undergoing hip replacement. Results from the co-ordinate measuring machine showed that the centre of the femoral head was predicted by the calliper to within 4.3 mm for offset (mean 1.6 (95% confidence interval (CI) 0.4 to 2.8)) and 2.4 mm for vertical height (mean -0.6 (95% CI -1.4 to 0.2)). The CT scans showed that offset and vertical height were restored to within 8 mm (mean -1 (95% CI -2.1 to 0.6)) and -14 mm (mean 4 (95% CI 1.8 to 4.3)), respectively. Accurate assessment and restoration of the centre of the femoral head is feasible with a calliper. It is quick, inexpensive, simple to use and can be applied to any design of femoral component.

  2. Long Term Outcomes of Total Hip Arthroplasty in Young Patients under 30

    Directory of Open Access Journals (Sweden)

    Emilios Pakos

    2014-09-01

    Full Text Available Background:  We aimed to report outcomes of total hip arthroplasty (THA in very young patients under the year of 30.   Methods:  Thirty patients (45 hips with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications.   Results:  Within a mean follow-up time of 116 months the 10-year survival rate was 90.3%. All hips were revised due to aseptic loosening. No association was found among the tested parameters with increased revision rates.Three complications associated with the THA were recorded and managed conservatively. All patients had statistically significant improved clinical scores compared to the pre-operative period, despite the underlying disorder that compromised the condition in the majority of the patients. Conclusions:  Our study showed excellent long term outcomes of THA in patients younger than 30 years of age, comparable with those in older patients.

  3. Chronological changes in functional cup position at 10 years after total hip arthroplasty.

    Science.gov (United States)

    Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko

    2017-09-19

    This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.

  4. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  5. Personality, function and satisfaction in patients undergoing total hip or knee replacement.

    Science.gov (United States)

    Ramaesh, Rishikesan; Jenkins, Paul; Lane, Judith V; Knight, Sara; Macdonald, Deborah; Howie, Colin

    2014-03-01

    The aim of this study was to investigate the relationships between personality and joint-specific function, general physical and general mental health in patients undergoing total hip (THA) and knee arthroplasty (TKA). One hundred and eighty-four patients undergoing THA and 205 undergoing TKA were assessed using the Eysneck Personality Questionnaire, brief version (EPQ-BV). General physical and mental health was measured using the Short-Form 12 (SF-12) questionnaire and the EuroQol (EQ-5D). Joint-specific function was measured using the Oxford hip or knee score. The "unstable introvert" personality type was associated with poorer pre-operative function and health in patients with hip arthrosis. In patients with knee arthrosis, there was poorer general health in those with "stable extrovert" and "unstable introvert" types. Personality was not an independent predictor of outcome following TKA or THA. The main predictor was pre-operative function and health. Comorbidity was an important covariate of both pre-operative and postoperative function. Personality may play a role in the interaction of these disease processes with function and health perception. It may also affect the response and interpretation of psychometric and patient-reported outcome measures. It may be important to characterise and identify these traits in potential arthroplasty patients as it may help deliver targeted education and management to improve outcomes in certain groups.

  6. Older patients can accurately recall their preoperative health status six weeks following total hip arthroplasty.

    Science.gov (United States)

    Marsh, Jackie; Bryant, Dianne; MacDonald, Steven J

    2009-12-01

    In clinical trials, use of patient recall data would be beneficial when the collection of baseline data is impossible, such as in trauma situations. We investigated the ability of older patients to accurately recall their preoperative quality of life, function, and general health status at six weeks following total hip arthroplasty. We randomized consecutive patients who were fifty-five years of age or older into two groups. At each assessment, patients completed self-report questionnaires (at four weeks preoperatively, on the day of surgery, and at six weeks and three months postoperatively for Group 1 and at six weeks and three months postoperatively for Group 2). At six weeks postoperatively, all patients completed the questionnaires on the basis of their recollection of their preoperative health status. We evaluated the validity and reliability of recall ratings, the degree of error in recall ratings, and the effects of the use of recall data on power and sample size requirements. A total of 174 patients (mean age, seventy-one years) who were undergoing either primary or revision total hip arthroplasty were randomized and included in the analysis (118 patients were in Group 1 and fifty-six were in Group 2). Agreement between actual and recalled data was excellent for disease-specific questionnaires (intraclass correlation coefficient, 0.86, 0.87, and 0.88) and moderate for generic health measures (intraclass correlation coefficient, 0.48, 0.58, and 0.60). Increased error associated with recalled ratings compared with actual ratings necessitates minimal increases in sample size or results in small decreases in power. Patients undergoing total hip arthroplasty can accurately recall their preoperative health status at six weeks postoperatively.

  7. Experience with Designing and Implementing a Bundled Payment Program for Total Hip Replacement.

    Science.gov (United States)

    Whitcomb, Winthrop F; Lagu, Tara; Krushell, Robert J; Lehman, Andrew P; Greenbaum, Jordan; McGirr, Joan; Pekow, Penelope S; Calcasola, Stephanie; Benjamin, Evan; Mayforth, Janice; Lindenauer, Peter K

    2015-09-01

    Bundled payments, also known as episode-based payments, are intended to contain health care costs and promote quality. In 2011 a bundled payment pilot program for total hip replacement was implemented by an integrated health care delivery system in conjunction with a commercial health plan subsidiary. In July 2015 the Centers for Medicare & Medicaid Services (CMS) proposed the Comprehensive Care for Joint Replacement Model to test bundled payment for hip and knee replacement. Stakeholders were identified and a structure for program development and implementation was created. An Oversight Committee provided governance over a Clinical Model Subgroup and a Financial Model Subgroup. The pilot program included (1) a clinical model of care encompassing the period from the preoperative evaluation through the third postoperative visit, (2) a pricing model, (3) a program to share savings, and (4) a patient engagement and expectation strategy. Compared to 32 historical controls-patients treated before bundle implementation-45 post-bundle-implementation patients with total hip replacement had a similar length of hospital stay (3.0 versus 3.4 days, p=.24), higher rates of discharge to home or home with services than to a rehabilitation facility (87% versus 63%), similar adjusted median total payments ($22,272 versus $22,567, p=.43), and lower median posthospital payments ($704 versus $1,121, p=.002), and were more likely to receive guideline-consistent care (99% versus 95%, p=.05). The bundled payment pilot program was associated with similar total costs, decreased posthospital costs, fewer discharges to rehabilitation facilities, and improved quality. Successful implementation of the program hinged on buy-in from stakeholders and close collaboration between stakeholders and the clinical and financial teams.

  8. Detection of occult, undisplaced hip fractures with a dual-energy CT algorithm targeted to detection of bone marrow edema.

    Science.gov (United States)

    Reddy, T; McLaughlin, P D; Mallinson, P I; Reagan, A C; Munk, P L; Nicolaou, S; Ouellette, H A

    2015-02-01

    The purpose of this study is to describe our initial clinical experience with dual-energy computed tomography (DECT) virtual non-calcium (VNC) images for the detection of bone marrow (BM) edema in patients with suspected hip fracture following trauma. Twenty-five patients presented to the emergency department at a level 1 trauma center between January 1, 2011 and January 1, 2013 with clinical suspicion of hip fracture and normal radiographs were included. All CT scans were performed on a dual-source, dual-energy CT system. VNC images were generated using prototype software and were compared to regular bone reconstructions by two musculoskeletal radiologists in consensus. Radiological and/or clinical diagnosis of fracture at 30-day follow-up was used as the reference standard. Twenty-one patients were found to have DECT-VNC signs of bone marrow edema. Eighteen of these 21 patients were true positive and three were false positive. A concordant fracture was clearly seen on bone reconstruction images in 15 of the 18 true positive cases. In three cases, DECT-VNC was positive for bone marrow edema where bone reconstruction CT images were negative. Four patients demonstrated no DECT-VNC signs of bone marrow edema: two cases were true negative, two cases were false negative. When compared with the gold standard of hip fracture determined at retrospective follow-up, the sensitivity of DECT-VNC images of the hip was 90 %, specificity was 40 %, positive predictive value was 86 %, and negative predictive value was 50 %. Our initial experience would suggest that DECT-VNC is highly sensitive but poorly specific in the diagnosis of hip fractures in patients with normal radiographs. The value of DECT-VNC primarily lies in its ability to help detect fractures which may be subtle or undetectable on bone reconstruction CT images.

  9. Hypertrophy of the tensor fascia lata muscle as a complication of total hip arthroplasty.

    Science.gov (United States)

    Rodríguez-Roiz, Juan Miguel; Bori, Guillem; Tomas, Xavier; Fernández-Valencia, Jenaro A; García-Díez, Ana Isabel; Pomés, Jaume; Garcia, Sebastián

    2017-02-01

    Hypertrophy of the tensor fascia lata muscle (HTFLM) is a rare complication after total hip arthroplasty (THA) and is a potential source of pain, palpable mass, or both. We retrospectively analyzed 1285 primary THAs and 482 THA revisions (THAR) performed at our center from 2008 to 2014. Among these, five patients had HTFLM (average age 68.8 years). The type of surgery and symptoms were evaluated, as were imaging studies (CT or MRI) of both hips (10 hips), and functional outcomes with the Merle d'Aubigné score. The suspected diagnosis was established at an average of 30.2 months after surgery. Four cases occurred after THA and one case after THAR. A modified Hardinge approach was used in four cases and a Röttinger approach in one case. Two cases had pain and palpable mass in the trochanteric region and three cases only pain. The asymmetric HTFLM of the THA side against the nonsurgical side was confirmed by measuring the cross section of the tensor fascia lata muscle on imaging. The sartorius muscle was measured for reference in each case. The Merle d'Aubigne scale had a mean value of 16.6 (range 13-18) at 38 months after the procedure. HTFLM after THA is a benign condition that could be mistaken for a tumor when presenting as a palpable mass. We propose that it should be considered in the differential diagnosis of pain in the lateral aspect of hips that have previously undergone THA.

  10. Duration and frequency of every day activities in total hip patients.

    Science.gov (United States)

    Morlock, M; Schneider, E; Bluhm, A; Vollmer, M; Bergmann, G; Müller, V; Honl, M

    2001-07-01

    Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose of this study was to develop and apply a system for the determination of frequency and duration of patient activities in their habitual environment and to compare the results to a clinical outcome score (Harris hip score).A portable activity monitoring system (weight 1.6 kg including batteries) was designed using a Palm top computer, 2 inclination sensors for the thigh and calf and one goniometer positioned at the knee joint. An algorithm was developed to identify frequency and duration of the activities lying, sitting, standing, walking and stair climbing from the signals of the 3 sensors. 42 patients participated in the study and were equipped with the system in the morning at their home. Datasets of 31 patients (age 62.5+/-11.5 y) covered more than 6h (9.8 +/- 1.6 h) and were included in the analysis. Prosthesis specific data as well as the Harris hip score were collected. The most frequent patient activity was sitting (44.3% of the time), followed by standing (24.5%), walking (10.2%), lying (5.8%) and stair climbing (0.4%). The median number of steps/stairs was 6048/164. The number of step cycles representing one year in vivo use should, consequently, be increased to 1.1 million. The Harris hip score (91.4 +/- 9.8) correlated significantly with the number of stairs (r(2) = 0.26, p = 0.003) and showed a positive tendency with the number of steps per day. No differences in activity levels between prosthesis specific factors were found.

  11. Total hip arthroplasty in chronic dialysis patients in the United States.

    Science.gov (United States)

    Abbott, Kevin C; Bucci, Jay R; Agodoa, Lawrence Y

    2003-01-01

    The national incidence of and factors associated with total hip arthroplasty (THA) in chronic dialysis patients has never been reported. We therefore performed an historical cohort study of 375,857 chronic dialysis patients listed in the 2000 United States Renal Data System between 1 April 1995 and 31 December 1999 and followed-up until 14 May 2000. Primary outcomes were associations with hospitalizations for a primary discharge code of THA (ICD9 procedure code 81.51x) after initiation of dialysis. Dialysis patients had a cumulative incidence of THA of 35 episodes/10,000 person-years, compared to 5.3/10,000 in the general population. The leading indication for THA was osteoarthritis of the hip and pelvis (58% of cases). However, the strongest risk factor for THA in dialysis patients was end-stage renal disease (ESRD) due to systemic lupus erythematosus (SLE, adjusted rate ratio (ARR), 6.80, 95% CI 4.62-10.03, in whom avascular necrosis of the hip was the most common indication, 68.4%). The database did not include information on use of corticosteroids. Diabetic recipients were significantly less likely to receive THA, as were males, and African Americans. Mortality after THA was 0.25% at thirty days and 30% at three years, not significantly different from the expected mortality of dialysis, adjusted for comorbidity. The most common indication for THA in dialysis patients is osteoarthritis of the hip, similar to the general population. Patients with SLE are more likely to receive THA which is well tolerated and not associated with increased mortality in this population, perhaps reflecting selection bias due to appropriate screening for this elective procedure.

  12. Acute bone marrow edema of the hip: role of MR imaging

    International Nuclear Information System (INIS)

    Karantanas, Apostolos H.

    2007-01-01

    Acute bone marrow edema of the hip is a diagnostic challenge for both radiologists and clinicians. Marrow edema is often seen in patients with hip pain and restriction of motion. In patients with acute non-traumatic hip pain, whose radiographs are negative or inconclusive, MR imaging is the imaging study of choice. MR imaging is the most sensitive and specific imaging technique for detecting transient osteoporosis and osteonecrosis, as well as for detecting and staging fractures and microfractures. MR imaging is able to show marrow involvement in various inflammatory disorders and to diagnose reactive marrow edema from femoroacetabular impingment and greater trochanteric pain syndrome. In patients with septic arthritis, it may also depict associated marrow edema and suggest its reactive or infectious origin. For the neoplastic disorders, although plain radiographs should be the initial examination, MR imaging may follow for assessing extension to the surrounding soft tissues and/or associated pathologic fracture, facilitating thus the treatment planning. Computed tomography is more accurate compared with MR imaging in diagnosing intra-articular osteoid osteomas. (orig.)

  13. Acute bone marrow edema of the hip: role of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, Apostolos H. [University Hospital, Department of Radiology, Stavrakia, Heraklion, Crete (Greece)

    2007-09-15

    Acute bone marrow edema of the hip is a diagnostic challenge for both radiologists and clinicians. Marrow edema is often seen in patients with hip pain and restriction of motion. In patients with acute non-traumatic hip pain, whose radiographs are negative or inconclusive, MR imaging is the imaging study of choice. MR imaging is the most sensitive and specific imaging technique for detecting transient osteoporosis and osteonecrosis, as well as for detecting and staging fractures and microfractures. MR imaging is able to show marrow involvement in various inflammatory disorders and to diagnose reactive marrow edema from femoroacetabular impingment and greater trochanteric pain syndrome. In patients with septic arthritis, it may also depict associated marrow edema and suggest its reactive or infectious origin. For the neoplastic disorders, although plain radiographs should be the initial examination, MR imaging may follow for assessing extension to the surrounding soft tissues and/or associated pathologic fracture, facilitating thus the treatment planning. Computed tomography is more accurate compared with MR imaging in diagnosing intra-articular osteoid osteomas. (orig.)

  14. Long-Term Outcome after Rehabilitation of Bilateral Total Hip Arthroplasty in Renal Transplant Recipient – A Case Report

    Directory of Open Access Journals (Sweden)

    Erieta Nikolikj Dimitrova

    2016-02-01

    CONCLUSION: Rehabilitation is integral part of multidisciplinary treatment of renal transplant recipient after total hip arthroplasty. Regular exercise training of these patients is very important for improving of their long-term outcome.

  15. Time-based analysis of total cost of patient episodes: a case study of hip replacement.

    Science.gov (United States)

    Peltokorpi, Antti; Kujala, Jaakko

    2006-01-01

    Healthcare in the public and private sectors is facing increasing pressure to become more cost-effective. Time-based competition and work-in-progress have been used successfully to measure and improve the efficiency of industrial manufacturing. Seeks to address this issue. Presents a framework for time based management of the total cost of a patient episode and apply it to the six sigma DMAIC-process development approach. The framework is used to analyse hip replacement patient episodes in Päijät-Häme Hospital District in Finland, which has a catchment area of 210,000 inhabitants and performs an average of 230 hip replacements per year. The work-in-progress concept is applicable to healthcare--notably that the DMAIC-process development approach can be used to analyse the total cost of patient episodes. Concludes that a framework, which combines the patient-in-process and the DMAIC development approach, can be used not only to analyse the total cost of patient episode but also to improve patient process efficiency. Presents a framework that combines patient-in-process and DMAIC-process development approaches, which can be used to analyse the total cost of a patient episode in order to improve patient process efficiency.

  16. Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling

    NARCIS (Netherlands)

    Kerner, J.; Huiskes, H.W.J.; Lenthe, van G.H.; Weinans, H.; Rietbergen, van B.; Engh, C.A.; Amis, A.A.

    1999-01-01

    Periprosthetic adaptive bone remodelling after total hip arthroplasty can be simulated in computer models, combining bone remodelling theory with finite element analysis. Patient specific three-dimensional finite element models of retrieved bone specimens from an earlier bone densitometry (DEXA)

  17. Bone marrow edema pattern in advanced hip osteoarthritis: quantitative assessment with magnetic resonance imaging and correlation with clinical examination, radiographic findings, and histopathology

    International Nuclear Information System (INIS)

    Taljanovic, Mihra S.; Schwartz, Stephanie A.; Graham, Anna R.; Benjamin, James B.; Gmitro, Arthur F.; Krupinski, Elizabeth A.; Hunter, Tim B.; Resnick, Donald L.

    2008-01-01

    To correlate the amount of bone marrow edema (BME) calculated by magnetic resonance imaging(MRI) with clinical findings, histopathology, and radiographic findings, in patients with advanced hip osteoarthritis(OA). The study was approved by The Institutional Human Subject Protection Committee. Coronal MRI of hips was acquired in 19 patients who underwent hip replacement. A spin echo (SE) sequence with four echoes and separate fast spin echo (FSE) proton density (PD)-weighted SE sequences of fat (F) and water (W) were acquired with water and fat suppression, respectively. T2 and water:fat ratio calculations were made for the outlined regions of interest. The calculated MRI values were correlated with the clinical, radiographic, and histopathologic findings. Analyses of variance were done on the MRI data for W/(W + F) and for T2 values (total and focal values) for the symptomatic and contralateral hips. The values were significantly higher in the study group. Statistically significant correlations were found between pain and total W/(W + F), pain and focal T2 values, and the number of microfractures and calculated BME for the focal W/(W + F) in the proximal femora. Statistically significant correlations were found between the radiographic findings and MRI values for total W/(W + F), focal W/(W + F) and focal T2 and among the radiographic findings, pain, and hip movement. On histopathology, only a small amount of BME was seen in eight proximal femora. The amount of BME in the OA hip, as measured by MRI, correlates with the severity of pain, radiographic findings, and number of microfractures. (orig.)

  18. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  19. No Correlation Between Press Ganey Survey Responses and Outcomes in Post-Total Hip Arthroplasty Patients.

    Science.gov (United States)

    Chughtai, Morad; Gwam, Chukwuweike U; Khlopas, Anton; Sodhi, Nipun; Delanois, Ronald E; Spindler, Kurt P; Mont, Michael A

    2018-03-01

    In the era of the online orthopedic market, patients tend to equate publicly available online satisfaction surveys with what they presume their ultimate surgical outcome will be. Therefore, the purpose of this study was to assess whether there is a correlation between Press Ganey (PG) scores and (1) Hip Western Ontario and McMaster Universities Osteoarthritis Index and Harris Hip Score; (2) Short Form-12 and Short Form-36 scores; (3) University of California Los Angeles and Visual Analog Scale scores assessed at a mean of 3 years (range, 1 to 6 years) after surgery. In addition, we assessed whether (4) these correlations persist in patients who were evaluated under 2 years and 3 or more years after surgery. Six-hundred ninety-two patients from November 2009 to January 2015 were identified from our institutional PG database. One-hundred ninety (27%) responded to the survey. One-hundred forty-nine (78%) patients were given the total hip arthroplasty assessment tools at a minimum of 2-year follow-up, and 33 patients (17%) completed their survey before 2 years after surgery. We assessed whether overall hospital rating scores correlated with the above assessment tools. Pearson correlation analysis revealed no correlation between the PG survey score and the assessment tools. HHS had the highest correlation coefficient (r = .120; P = .316); however, this was not significant. After removing the patients who had their follow-up survey administered under 2 years after surgery (33 patients), there was still no statistically significant correlation between the above-mentioned outcome scores and PG overall hospital rating (P > .05). No statistically significant relationship was found between commonly used total hip arthroplasty assessment tools and the PG overall hospital rating. Based on these results, PG surveys may not be a suitable implementation of the Center for Medicare and Medicaid services. A set of measures that can be widely collected and reported by hospitals for

  20. Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

    Science.gov (United States)

    Winkler, Heinz

    2009-09-04

    Infection of a total hip replacement (THR) is considered a devastating complication, necessitating its complete removal and thorough debridement of the site. It is undoubted that one stage exchange, if successful, would provide the best benefit both for the patient and the society. Still the fear of re-infection dominates the surgeons decisions and in the majority of cases directs them to multiple stage protocols. However, there is no scientifically based argument for that practice. Successful eradication of infection with two stage procedures is reported to average 80% to 98%. On the other hand a literature review of Jackson and Schmalzried (CORR 2000) summarizing the results of 1,299 infected hip replacements treated with direct exchange (almost exclusively using antibiotic loaded cement), reports of 1,077 (83%) having been successful. The comparable results suggest, that the major factor for a successful outcome with traditional approaches may be found in the quality of surgical debridement and dead space management. Failures in all protocols seem to be caused by small fragments of bacterial colonies remaining after debridement, whereas neither systemic antibiotics nor antibiotic loaded bone cement (PMMA) have been able to improve the situation significantly. Reasons for failure may be found in the limited sensitivity of traditional bacterial culturing and reduced antibiotic susceptibility of involved pathogens, especially considering biofilm formation. Whenever a new prosthesis is implanted into a previously infected site the surgeon must be aware of increased risk of failure, both in single or two stage revisions. Eventual removal therefore should be easy with low risk of additional damage to the bony substance. On the other hand it should also have potential of a good long term result in case of success. Cemented revisions generally show inferior long term results compared to uncemented techniques; the addition of antibiotics to cement reduces its

  1. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    Science.gov (United States)

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip

  2. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  3. Artroplastia total do quadril não cimentada em pacientes com artrite reumatóide Uncemented total hip arthroplasty in patients with rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Bruno Tavares Rabello

    2008-08-01

    relief. No case of loosening was seen. Two cases had complications: one patient had deep venous thrombosis (DVT, confirmed by doppler, and one case of fracture during surgery, distal to the calcar bone, treated with cerclage, with no repercussion in the quality of clinical and radiographic results of this patient. CONCLUSION: After a mean follow-up of 5.6 years, results show that uncemented total hip arthroplasty may be a satisfactory option in coxoarthroses of patients with rheumatoid arthritis.

  4. Measuring the migration of the components and polyethylene wear after total hip arthroplasty: beads and specialised radiographs are not necessary.

    Science.gov (United States)

    Devane, P A; Horne, J G; Foley, G; Stanley, J

    2017-10-01

    This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient's bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA). Models of the patient's acetabular and femoral component obtained from the manufacturer and models of the patient's pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients. Migration of the acetabular and femoral components can be measured with limits of agreement (LOA) of 0.37 mm and 0.33 mm, respectively. Penetration of the femoral head can be measured with LOA of 0.161 mm. The migration of components and polyethylene wear can be measured without needing specialised radiographs. Accurate measurement may allow earlier prediction of failure after THA. Cite this article: Bone Joint J 2017;99-B:1290-7. ©2017 The British Editorial Society of Bone & Joint Surgery.

  5. Revision rates for metal-on-metal hip resurfacing and metal-on-metal total hip arthroplasty – a systematic review

    DEFF Research Database (Denmark)

    Ras Sørensen, Sofie-amalie L.; Jørgensen, Henrik L.; Sporing, Sune L.

    2016-01-01

    Purpose To compare revision rates of metal-on-metal (MoM) hip resurfacing (HRS) and MoM total hip arthroplasty (THA), as well as the primary causes for revisions. Methods The PubMed database was queried for potentially relevant articles addressing MoMTHA and MoMHRS, a total of 51 articles were....... The odds ratio was 1.25 (1.03:1.53) 95% CI (p = 0.03) (MoMHRS vs. MoMTHA). The studies of hip prostheses were separated into 2 categories of short- and long-term (more or less than 5 years). Short-term revision rate for MoMTHA was 4.5% after 4.8 years, and for MoMHRS 4.0% after 4.2 years. The odds ratio...

  6. Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.

    Science.gov (United States)

    Arabnejad, Sajad; Johnston, Burnett; Tanzer, Michael; Pasini, Damiano

    2017-08-01

    Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with tunable mechanical properties is introduced for use in hip replacement design. The implant macro geometry is based off of a short stem taper-wedge implant compatible with minimally invasive hip replacement surgery. The implant micro-architecture is fine-tuned to locally mimic bone tissue properties which results in minimum bone resorption secondary to stress shielding. We present a systematic approach for the design of a 3D printed fully porous hip implant that encompasses the whole activity spectrum of implant development, from concept generation, multiscale mechanics of porous materials, material architecture tailoring, to additive manufacturing, and performance assessment via in vitro experiments in composite femurs. We show that the fully porous implant with an optimized material micro-structure can reduce the amount of bone loss secondary to stress shielding by 75% compared to a fully solid implant. This result also agrees with those of the in vitro quasi-physiological experimental model and the corresponding finite element model for both the optimized fully porous and fully solid implant. These studies demonstrate the merit and the potential of tuning material architecture to achieve a substantial reduction of bone resorption secondary to stress shielding. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1774-1783, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. Total knee replacement influences both knee and hip joint kinematics during stair climbing

    OpenAIRE

    Saari, Tuuli; Tranberg, Roy; Zügner, Roland; Uvehammer, Johan; Kärrholm, Johan

    2004-01-01

    A gait analysis system was used to evaluate the kinematics of the hip and knee during stair ascending and descending after operation with total knee replacement. Patients with 5° varus/valgus alignment or less were selected randomly to receive either a flat or a concave tibial component with retention of the posterior cruciate ligament. Patients who had more than 5° varus/valgus alignment and/or an extension defect of 10° or more were selected randomly to receive the concave or posterior-stab...

  8. Comparison of complications in transtrochanteric and anterolateral approaches in primary total hip arthroplasty.

    LENUS (Irish Health Repository)

    Cashman, James P

    2008-11-01

    Three surgical approaches to primary total hip arthroplasty (THA) have been in use since Charnley popularized the transtrochanteric approach. This study was designed to examine the difference in morbidity between the transtrochanteric approach and the anterolateral approach in primary THA. Information on 891 patients who underwent primary THA performed by a single surgeon was collected prospectively between 1998 and 2003 using a modified SF-36 form, preoperatively, intraoperatively, and at 3 months postoperatively. The transtrochanteric group had higher morbidity and more patients who were dissatisfied with their THA. There was a greater range of motion in the anterolateral group.

  9. Comparison of Procedural Sedation for the Reduction of Dislocated Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Jonathan E. dela Cruz

    2014-02-01

    Full Text Available Introduction: Various types of sedation can be used for the reduction of a dislocated total hip arthroplasty. Traditionally, an Opiate/Benzodiazepine combination has been employed. The use of other pharmacologic agents, such as Etomidate and Propofol, has more recently gained popularity. Currently no studies directly comparing these sedation agents have been carried out. The purpose of this study is to compare differences in reduction and sedation outcomes including recovery times of these three different sedation agents. Methods: A retrospective chart review was performed examining 198 patient’s charts who presented with dislocated total hip arthroplasty at two academic affiliated medical centers. The patients were organized into groups according to the type of sedation agent used during their reduction. The percentages of reduction and sedation complications were calculated along with overall recovery times. Reduction complications included fracture, skin or neurovascular injury, and failure of reduction requiring general anesthesia. Sedation complications included use of bag-valve mask and artificial airway, intubation, prolonged recovery, use of a reversal agent, and inability to achieve sedation. The data were then compared for each sedation agent. Results: The reduction complications rates found were 8.7% in the Propofol group, 24.68% in the Etomidate, and 28.85% in the Opiate/Benzodiazepine groups. The reduction complication rate in the Propofol group was significantly different than those of the other two agents (p≤0.01. Sedation complications were found to happen 7.25% of the time in the Propofol group, 11.69% in the Etomidate group, and 21.25% in the Opiate/ Benzodiazepine group with Propofol having complication rates significantly different than that of the Opiate/Benzodiazepine group (p=0.02. Average lengths of recovery were 25.17 minutes for Propofol, 30.83 minutes for Etomidate, and 44.35 minutes for Opiate/ Benzodiazepine with

  10. Rehabilitation of patients aged 65 and over after total hip replacement

    DEFF Research Database (Denmark)

    Hørdam, Britta

    by a randomised clinical trial by using telephone interviews and counseling postoperatively, and testing improvement in patients´health status after THR. The last study involved testing the effect of nursing intervention by providing a measurement of patients´healthrelated quality of life.......The overall aim of this thesis was to investigate improvement in health status of patients aged 65 and over after total hip replacement (THR) as a result of nursing rehabilitation. The projects conssits of three studies, first a description of patients´health status after THR, followed...

  11. Serious renal and urological complications in fast-track primary total hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Bjerregaard, Lars S; Jorgensen, Christoffer C; Kehlet, Henrik

    2016-01-01

    of stay > 4 days or 30-day readmissions after fast-track THA and TKA, we conducted a detailed observational study based upon prospectively collected pre-operative data and a complete 30-day follow-up on complications and re-admissions in a unselected cohort of 8,804 consecutive fast-track THAs and TKAs......BACKGROUND: Overall medical complications have been reduced after fast-track total hip (THA) and knee arthroplasty (TKA), but data on specific renal and urological (RU) complications are limited. METHODS: To describe the incidence and consequences of serious RU complications resulting in length...

  12. Development of a protocol for the kinematic analysis of movement in patients with total hip arthroplasty

    OpenAIRE

    Mateu Pla, Joan

    2015-01-01

    The aim of this final degree project is to study and analyze the kinematics of the human body lower limbs. First of all, it is extremely important to establish a protocol in order to compare two patients operated with two different techniques of total hip arthroplasty. The three usual movements that are employed to make this comparison are gait, sit-to-stand and stairs climbing. A three-dimensional full body model is implemented and the kinematic parameters (angles) necessary for the st...

  13. Post-anaesthesia care unit stay after total hip and knee arthroplasty under spinal anaesthesia

    DEFF Research Database (Denmark)

    Lunn, T H; Kristensen, B B; Gaarn-Larsen, L

    2012-01-01

    patients operated with primary unilateral total hip or knee arthroplasty (THA or TKA) under spinal anaesthesia were included in this hypothesis-generating, prospective, observational cohort study during a 4-month period. Surgical technique, analgesia, and perioperative care were standardized. Well......BACKGROUND: Post-anaesthesia care unit (PACU) admission must be well founded and the stay as short as possible without compromising patient safety. However, within the concept of fast-track surgery, studies are limited in addressing the question: why are patients staying in the PACU? METHODS: All...

  14. The Use of a Supra-Acetabular Antibiotic-Loaded Cement Shelf to Improve Hip Stability in First-Stage Infected Total Hip Arthroplasty.

    Science.gov (United States)

    Drexler, Michael; Kuzyk, Paul R T; Koo, Kevin; Gross, Allan E; Kosashvili, Yona; Reischl, Nickola; Rutenberg, Tal Frenkel; Safir, Oleg

    2016-11-01

    Antibiotic-loaded cement spacers in first-stage revision total hip arthroplasty (THA) for managing infection are associated with high dislocation and fracture rates. The aim of this study was to report the use of an antibiotic-loaded cemented supra-acetabular roof augmentation to reinforce hip stability after cement spacer insertion for first-stage total hip revision in the treatment of infected THA. We retrospectively reviewed a consecutive series of 50 THAs involving 47 patients with an infected hip requiring staged revisions of THA. We documented dislocation, reinfection, and time for revision and outcome. There were no cases of hip dislocation, cement fractures, or any other technical complications associated with the use of the roof augmentation lip. Thirteen cases (26%) had a cemented spacer for longer than 120 days. Seven (14%) cases had recurrent infection after staged revision THA. The antibiotic-loaded cemented supra-acetabular roof augment improved femoral head spacer coverage for patients requiring a staged revision THA for infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Sexual activity after total hip replacement in Korean patients: how they do, what they want, and how to improve.

    Science.gov (United States)

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2013-12-01

    Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.

  16. Patients' Expectations Impact Their Satisfaction following Total Hip or Knee Arthroplasty.

    Science.gov (United States)

    Neuprez, Audrey; Delcour, Jean-Pierre; Fatemi, Firouzeh; Gillet, Philippe; Crielaard, Jean-Michel; Bruyère, Olivier; Reginster, Jean-Yves

    2016-01-01

    The objective of this study was to assess the number and magnitude of preoperative expectations and to correlate them with the degree of satisfaction expressed one year after Total Hip Arthroplasty (THA) or Total Knee Arthroplasty (TKA), in patients with severe and painful osteoarthritis (OA). Preoperative expectations (within 20 days prior to surgery) and postoperative satisfaction (one year after the intervention) were measured using the previously validated French version of the Hospital for Special Surgery Hip or Knee Replacement Expectations Survey. Postoperative satisfaction was measured using a specific scale, following the same methodology as that used for the assessment of expectations. Prediction of the satisfaction of the patients was performed using multivariate linear regression modelling. A total of 138 patients (80 THA and 58 TKA) completed the two parts of the study. The expectations score (mean ± SD) (range 0-100) was 72.58 ± 12.63 before THA and 69.10 ± 13.72 before TKA (p = 0.13). The number of expectations expressed was 14.34 ± 1.32 (out of a potential maximum of 18) before THA and 14.70 ± 2.29 (out of a potential maximum of 19) before TKA. After 1 year, THA generated a significantly higher degree of satisfaction compared to TKA (69.70 ± 14.46 v 60.44 ± 17.54, poptimal preoperative interaction between health care providers and patients, to allow patients a chance to foresee a reasonable outcome after TJA.

  17. Comparison of hip function and quality of life of total hip arthroplasty and resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint at 5 years.

    Science.gov (United States)

    Costa, Matthew L; Achten, Juul; Foguet, Pedro; Parsons, Nicholas R

    2018-03-12

    To compare the medium-term clinical effectiveness of total hip arthroplasty and resurfacing arthroplasty. Single centre, two-arm, parallel group, assessor blinded, randomised controlled trial with 1:1 treatment allocation. A large teaching hospital in England. 122 patients older than 18 years with severe arthritis of the hip joint, suitable for resurfacing arthroplasty of the hip. Patients were excluded if they were considered to be unable to adhere to trial procedures or complete questionnaires. Total hip arthroplasty (replacement of entire femoral head and neck); hip resurfacing arthroplasty (replacement of the articular surface of femoral head only, femoral neck remains intact). Both procedures replaced the articular surface of the acetabulum. The outcome measures were hip function assessed using the Oxford Hip Score (OHS) and health-related quality of life assessed using the EuroQol (EQ-5D). Patients were followed up annually for a minimum of 5 years. Outcome data were modelled using the generalised estimating equation methodology to explore temporal variations during follow-up. 60 patients were randomly assigned to hip resurfacing arthroplasty and 62 to total hip arthroplasty. 95 (78%) of the 122 original study participants provided data at 5 years. There was a small decrease in both hip functions and quality of life in both groups of patients each year during the 5-year follow-up period. However, there was no evidence of a significant difference between treatments group in the OHS (P=0.333) or the EQ-5D (P=0.501). We previously reported no difference in outcome in the first year after surgery. The current medium-term results also show no evidence of a difference in hip function or health-related quality of life in the 5 years following a total hip arthroplasty versus resurfacing arthroplasty. ISRCTN33354155. UKCRN 4093. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use

  18. Additive effects of nutritional supplementation, together with bisphosphonates, on bone mineral density after hip fracture: a 12-month randomized controlled study

    Directory of Open Access Journals (Sweden)

    Flodin L

    2014-07-01

    Full Text Available Lena Flodin,1,2 Maria Sääf,3 Tommy Cederholm,4 Amer N Al-Ani,2,5 Paul W Ackermann,5,6 Eva Samnegård,7 Nils Dalen,7 Margareta Hedström2,51Department of Geriatric Medicine, Karolinska University Hospital Stockholm, Sweden; 2Department of Clinical Science, Intervention, and Technology, Karolinska Institutet, Stockholm, Sweden; 3Department of Endocrinology, Metabolism, and Diabetes, Karolinska University Hospital, Stockholm, Sweden; 4Department of Public Health and Caring Sciences, Clinical Nutrition and Metabolism, Uppsala University, Uppsala, Sweden; 5Department of Orthopedics, Karolinska University Hospital, Stockholm, Sweden; 6Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden; 7Department of Clinical Science, Division of Orthopedics, Karolinska Institutet, Danderyd Hospital, Stockholm, SwedenBackground: After a hip fracture, a catabolic state develops, with increased bone loss during the first year. The aim of this study was to evaluate the effects of postoperative treatment with calcium, vitamin D, and bisphosphonates (alone or together with nutritional supplementation on total hip and total body bone mineral density (BMD.Methods: Seventy-nine patients (56 women, with a mean age of 79 years (range, 61–96 years and with a recent hip fracture, who were ambulatory before fracture and without severe cognitive impairment, were included. Patients were randomized to treatment with bisphosphonates (risedronate 35 mg weekly for 12 months (B; n=28, treatment with bisphosphonates along with nutritional supplementation (40 g protein, 600 kcal daily for the first 6 months (BN; n=26, or to controls (C; n=25. All participants received calcium (1,000 mg and vitamin D3 (800 IU daily. Total hip and total body BMD were assessed with dual-energy X-ray absorptiometry at baseline, 6, and 12 months. Marker of bone resorption C-terminal telopeptide of collagen I and 25-hydroxy vitamin D were analyzed in serum

  19. Is There a Role for Preoperative Iron Supplementation in Patients Preparing for a Total Hip or Total Knee Arthroplasty?

    Science.gov (United States)

    Petis, Stephen M; Lanting, Brent A; Vasarhelyi, Edward M; Naudie, Douglas D R; Ralley, Fiona E; Howard, James L

    2017-09-01

    Several treatment modalities exist for the treatment of perioperative anemia. We determined the effect of oral iron supplementation on preoperative anemia, and the use of blood-conserving interventions before total hip arthroplasty (THA) and total knee arthroplasty (TKA). A total of 3435 total joint arthroplasties (1461 THAs and 1974 TKAs) were analyzed during 2 phases of a blood conservation program. The first phase used erythropoietin alfa (EPO) or intravenous (IV) iron for patients at risk for perioperative anemia. The second phase included these interventions, as well as preoperative iron supplementation. The effect on preoperative hemoglobin (Hb) and serum ferritin, as well as EPO and IV iron utilization, was determined. Oral iron therapy increased preoperative Hb level by 6 g/L (P iron reduced from 4% to 2% (P = .05) and 5% to 2% (P iron therapy reduced the burden of perioperative anemia and reduced utilization of other blood-conserving therapies before THA and TKA. Future research should delineate the cost-effectiveness of oral iron therapy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Assessment of changes in gait parameters and vertical ground reaction forces after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Bhargava P

    2007-01-01

    Full Text Available The principal objectives of arthroplasty are relief of pain and enhancement of range of motion. Currently, postoperative pain and functional capacity are assessed largely on the basis of subjective evaluation scores. Because of the lack of control inherent in this method it is often difficult to interpret data presented by different observers in the critical evaluation of surgical method, new components and modes of rehabilitation. Gait analysis is a rapid, simple and reliable method to assess functional outcome. This study was undertaken in an effort to evaluate the gait characteristics of patients who underwent arthroplasty, using an Ultraflex gait analyzer. Materials and Methods: The study was based on the assessment of gait and weight-bearing pattern of both hips in patients who underwent total hip replacement and its comparison with an age and sex-matched control group. Twenty subjects of total arthroplasty group having unilateral involvement, operated by posterior approach at our institution with a minimum six-month postoperative period were selected. Control group was age and sex-matched, randomly selected from the general population. Gait analysis was done using Ultraflex gait analyzer. Gait parameters and vertical ground reaction forces assessment was done by measuring the gait cycle properties, step time parameters and VGRF variables. Data of affected limb was compared with unaffected limb as well as control group to assess the weight-bearing pattern. Statistical analysis was done by′t′ test. Results: Frequency is reduced and gait cycle duration increased in total arthroplasty group as compared with control. Step time parameters including Step time, Stance time and Single support time are significantly reduced ( P value < .05 while Double support time and Single swing time are significantly increased ( P value < .05 in the THR group. Forces over each sensor are increased more on the unaffected limb of the THR group as compared to

  1. Total body and regional bone mineral content in hemodialysis patients

    International Nuclear Information System (INIS)

    Hagiwara, Satoshi; Aratani, Hideyui; Miki, Takami; Nishizawa, Yoshiki; Okamura, Terue; Koizumi, Yoshiko; Ochi, Hironobu; Morii, Hirotoshi

    1994-01-01

    Bone mineral content (BMC) in the total body and lumbar spine was evaluated in 126 hemodialysis patients (60 males, 66 females) by dual photon absorptiometry with the Norland DBD 2600. Measurements of: 1) total body BMC divided by lean body mass (BMC TB /LBM), 2) bone mineral density (BMD) of total body, 3) BMD of four regional sections (head, trunk, pelvis, and legs), and 4) BMD of lumbar spine, generally showed a significant decrease in the hemodialysis patients compared to the reference population. However, arm BMD did not show a significant difference between patients and control populations. The z-score of BMC TB /LBM declined significantly throughout the duration of hemodialysis, although that of the lumbar spine BMD did not. It should be noted that the degree of decrease in BMC was more prominent in the total body measurement than in the lumbar spine measurement. There was preferential osteopenia of the total body in the hemodialysis patients. Although the lumbar spine BMD showed a lower value than the control population, the lumbar spine is not the recommended region to monitor the BMD change in hemodialysis patients. (author)

  2. Can Patients Practice Strenuous Sports After Uncemented Ceramic-on-Ceramic Total Hip Arthroplasty?

    Science.gov (United States)

    Bonnin, Michel P.; Rollier, Jean-Charles; Chatelet, Jean-Christophe; Ait-Si-Selmi, Tarik; Chouteau, Julien; Jacquot, Laurent; Hannink, Gerjon; Saffarini, Mo; Fessy, Michel-Henri

    2018-01-01

    Background: Patients are often concerned about returning to sports after total hip arthroplasty (THA). Purpose: To (1) evaluate sports participation and motivation rates in a large cohort of patients who underwent uncemented THA with ceramic-on-ceramic bearings and (2) determine whether patients’ participation was associated with their motivation for each sport, preoperative demographics, or patient-reported outcomes. Study Design: Case-control study; Level of evidence, 3. Methods: We surveyed 1310 patients (aged sports as well as patient-reported outcome measure scores. A total of 1042 patients (1206 hips) returned questionnaires; the mean age at index surgery was 60.6 ± 8.8 years. Results: At least 51% of patients participated regularly or frequently in at least 1 light sport, 73% in at least 1 moderate sport, and 20% in at least 1 strenuous sport. Sports participation was strongly correlated with motivation (r = 0.97, P sports was significantly associated with age, body mass index, and sex. There were significant differences among patients who practiced various categories of sports as determined using the Oxford Hip Score (P = .008), but not with regard to the Forgotten Joint Score (P = .054). Conclusion: Only 20% of patients practiced strenuous sports regularly or frequently after THA, regardless of pain or discomfort. Participation in sports after THA is strongly correlated with motivation but not with level of discomfort. Longer term studies with a greater focus on complications and survival are necessary to determine whether high-impact sports compromise patient safety or implant longevity. PMID:29707594

  3. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study

    NARCIS (Netherlands)

    P.T.P.W. Burgers (Paul); M. Hoogendoorn (Martine); E.A.C. Van Woensel; R.W. Poolman (Rudolf); M. Bhandari (Mohit); P. Patka (Peter); E.M.M. van Lieshout (Esther)

    2016-01-01

    textabstractSummary: The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost

  4. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    Science.gov (United States)

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Total lymphatic irradiation and bone marrow in human heart transplantation

    International Nuclear Information System (INIS)

    Kahn, D.R.; Hong, R.; Greenberg, A.J.; Gilbert, E.F.; Dacumos, G.C.; Dufek, J.H.

    1984-01-01

    Six patients, aged 36 to 59 years, had heart transplants for terminal myocardial disease using total lymphatic irradiation (TLI) and donor bone marrow in addition to conventional therapy. All patients were poor candidates for transplantation because of marked pulmonary hypertension, unacceptable tissue matching, or age. Two patients are living and well more than four years after the transplants. Two patients died of infection at six and seven weeks with normal hearts. One patient, whose preoperative pulmonary hypertension was too great for an orthotopic heart transplant, died at 10 days after such a procedure. The other patient died of chronic rejection seven months postoperatively. Donor-specific tolerance developed in 2 patients. TLI and donor bone marrow can produce specific tolerance to donor antigens and allow easy control of rejection, but infection is still a major problem. We describe a new technique of administering TLI with early reduction of prednisone that may help this problem

  6. Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

    Science.gov (United States)

    Cross, Michael B; Nam, Denis; Mayman, David J

    2012-10-01

    Over the last several years, a trend towards increasing femoral head size in total hip arthroplasty to improve stability and impingement free range of motion has been observed. The specific questions we sought to answer in our review were: (1) What are the potential advantages and disadvantages of metal-on-metal, ceramic-on-ceramic, and metal-on-polyethylene bearings? (2) What is effect that femoral head size has on joint kinematics? (3) What is the effect that large femoral heads have on bearing surface wear? A PubMed search and a review of 2012 Orthopaedic Research Society abstracts was performed and articles were chosen that directly answered components of the specific aims and that reported outcomes with contemporary implant designs or materials. A review of the literature suggests that increasing femoral head size decreases the risk of postoperative dislocation and improves impingement free range of motion; however, volumetric wear increases with large femoral heads on polyethylene and increases corrosion of the stem in large metal-on-metal modular total hip arthroplasty (THA); however, the risk of potentially developing osteolysis or adverse reactions to metal debris respectively is still unknown. Further, the effect of large femoral heads with ceramic-on-ceramic THA is unclear, due to limited availability and published data. Surgeons must balance the benefits of larger head size with the increased risk of volumetric wear when determining the appropriate head size for a given patient.

  7. Preoperative information provided to Swedish and immigrant patients before total hip replacement.

    Science.gov (United States)

    Krupic, Ferid; Määttä, Sylvia; Garellick, Göran; Lyckhage, Elisabeth Dahlborg; Kärrholm, Johan

    2012-01-01

    Total hip replacement is an operation that usually leads to pain relief and improved health related quality of life (HRQoL). Previous studies have demonstrated the importance of information about upcoming surgery. Therefore, it was of interest to study how both immigrants, whose first language was not Swedish, and Swedish patients described pre-operative information. Individual interviews were conducted with 10 immigrants and 10 Swedish participants. The data were analysed using qualitative content analysis. The study was carried out in western Sweden from March to November 2010. The findings revealed that pre-operative information for all patients undergoing elective total hip replacement was limited. Patients from both groups expressed concern about inadequate preoperative information pertaining to the surgery, implant selection, pain relief, choice of anaesthesia, no or too short a time to put questions to the surgeon and an overall stressful situation. Adequate preoperative information is important for optimising pain relief and shortening the hospital stay. The fact that the patients overwhelmingly rated the preoperative information as inadequate may be due to several reasons. Mental distress and the two-week interval between the time when the patient received the information and the operation might have contributed to the low degree of retention.

  8. Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Smith-Bateman, C.; Malcolm, P.N.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Graves, M. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-06-15

    Aim: To describe the relative contribution of matrix size and bandwidth to artefact reduction in order to define optimal sequence parameters for metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Methods and materials: A phantom was created using a Charnley total hip replacement. Mid-coronal T1-weighted (echo time 12 ms, repetition time 400 ms) images through the prosthesis were acquired with increasing bandwidths (150, 300, 454, 592, and 781 Hz/pixel) and increasing matrixes of 128, 256, 384, 512, 640, and 768 pixels square. Signal loss from the prosthesis and susceptibility artefact was segmented using an automated tool. Results: Over 90% of the achievable reduction in artefacts was obtained with matrixes of 256 x 256 or greater and a receiver bandwidth of approximately 400 Hz/pixel or greater. Thereafter increasing the receiver bandwidth or matrix had little impact on reducing susceptibility artefacts. Increasing the bandwidth produced a relative fall in the signal-to-noise ratio (SNR) of between 49 and 56% for a given matrix, but, in practice, the image quality was still satisfactory even with the highest bandwidth and largest matrix sizes. The acquisition time increased linearly with increasing matrix parameters. Conclusion: Over 90% of the achievable metal artefact reduction can be realized with mid-range matrices and receiver bandwidths on a clinical 1.5 T system. The loss of SNR from increasing receiver bandwidth, is preferable to long acquisition times, and therefore, should be the main tool for reducing metal artefact.

  9. Risk factors for revision of primary total hip arthroplasty: a systematic review

    Directory of Open Access Journals (Sweden)

    Prokopetz Julian JZ

    2012-12-01

    Full Text Available Abstract Background Numerous papers have been published examining risk factors for revision of primary total hip arthroplasty (THA, but there have been no comprehensive systematic literature reviews that summarize the most recent findings across a broad range of potential predictors. Methods We performed a PubMed search for papers published between January, 2000 and November, 2010 that provided data on risk factors for revision of primary THA. We collected data on revision for any reason, as well as on revision for aseptic loosening, infection, or dislocation. For each risk factor that was examined in at least three papers, we summarize the number and direction of statistically significant associations reported. Results Eighty-six papers were included in our review. Factors found to be associated with revision included younger age, greater comorbidity, a diagnosis of avascular necrosis (AVN as compared to osteoarthritis (OA, low surgeon volume, and larger femoral head size. Male sex was associated with revision due to aseptic loosening and infection. Longer operating time was associated with revision due to infection. Smaller femoral head size was associated with revision due to dislocation. Conclusions This systematic review of literature published between 2000 and 2010 identified a range of demographic, clinical, surgical, implant, and provider variables associated with the risk of revision following primary THA. These findings can inform discussions between surgeons and patients relating to the risks and benefits of undergoing total hip arthroplasty.

  10. Should All Patients Be Included in Alternative Payment Models for Primary Total Hip Arthroplasty and Total Knee Arthroplasty?

    Science.gov (United States)

    Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin

    2016-09-01

    Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. PLCL1 rs7595412 variation is not associated with hip bone size variation in postmenopausal Danish women

    Directory of Open Access Journals (Sweden)

    Karsdal Morten A

    2009-12-01

    Full Text Available Abstract Background Bone size (BS variation is under strong genetic control and plays an important role in determining bone strength and fracture risk. Recently, a genome-wide association study identified polymorphisms associated with hip BS variation in the PLCL1 (phospholipase c-like 1 locus. Carriers of the major A allele of the most significant polymorphism, rs7595412, have around 17% larger hip BS than non-carriers. We therefore hypothesized that this polymorphism may also influence postmenopausal complications. Methods The effects of rs7595412 on hip BS, bone mineral density (BMD, vertebral fractures, serum Crosslaps and osteocalcin levels were analyzed in 1,191 postmenopausal Danish women. Results This polymorphism had no influence on hip and spine BS as well as on femur and spine BMD. Women carrying at least one copy of the A allele had lower levels of serum osteocalcin as compared with those homozygous for the G allele (p = 0.03 whereas no effect on serum Crosslaps was detected. Furthermore, women homozygous for the A allele were more affected by vertebral fractures than those carrying at least one copy of the G allele (p = 0.04. Conclusions In postmenopausal women, our results suggest that the PLCL1 rs7595412 polymorphism has no obvious effect on hip BS or BMD but may be nominally associated with increased proportion of vertebral fracture and increased levels of osteocalcin.

  12. Revision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-11-01

    Full Text Available Abstract We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean follow up period was 12.7 months (3 to 31. All patients reported relief of pain and excellent satisfaction scores. Two patients experienced stiffness up to three months post operatively. Pre operative Oxford, Harris and WOMAC hip scores were 39.1, 36.4 and 52.2 respectively. Mean post operative scores at last follow up were 17.4, 89.8 and 6.1 respectively (p

  13. Heavy reading in heavy metal : Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty

    NARCIS (Netherlands)

    Boomsma, M.F.

    2017-01-01

    In this thesis, we investigated the use of computer tomography (CT) for the screening of patients with a metal-on-metal (MoM) hip prosthesis in two patient cohorts. With a self-established CT grading scale, we have shown that CT is a reliable method for the diagnosis of postoperative pathological

  14. Tribology and total hip joint replacement: current concepts in mechanical simulation.

    Science.gov (United States)

    Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M

    2008-12-01

    Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.

  15. Revision Total Hip Arthroplasty Using a Modular Tapered Stem With Distal Fixation Good Short-Term Results in 125 Revisions

    DEFF Research Database (Denmark)

    Ovesen, Ole; Emmeluth, Claus; Hofbauer, Christian

    2009-01-01

    After 2 to 7 years we reviewed 125 prosthetic hip arthroplasty stem revisions using a modular tapered stem with distal fixation. Median age of these patients was 68 (33-92) years. Baseline and follow-up data were registered prospectively according to the Danish Hip Arthroplasty Registry. Survival...... system is very versatile, can be used in most femoral revision cases, and allows rapid bone remodeling. We did not find an increased number of complications compared to the literature. Further long-term follow-up, however, is essential......., free of any rerevision, was 94%. Harris Hip Score improved from average 44 to 85. Bony regeneration was an early and significant finding in most cases. Complications included 4 (3%) fractures intraoperatively and 8 (6%) dislocations, 4 (3%) deep infections, and 1 (1%) stem fracture. This modular taper...

  16. OPTIMAL IMPROVEMENT IN FUNCTION AFTER TOTAL HIP AND KNEE REPLACEMENT: HOW DEEP DO YOU KNOW YOUR PATIENT’S MIND?

    Science.gov (United States)

    De Caro, M F; Vicenti, G; Abate, A; Picca, G; Leoncini, V; Lomuscio, M; Casalino, A; Solarino, G; Moretti, B

    2015-01-01

    Osteoarthritis (OA) of the hip and knee causes pain and loss of joint mobility, leading to limitations in physical function. When conservative treatment fails total hip and knee replacement is a cost-effective surgical option. Patients have high expectations regarding functional outcome after these procedures. If such expectations are not met, they may still be dissatisfied with the outcome of a technically successful procedure. Recently, numerous studies reported that psychological factors can influence the outcome of total knee replacement (tkr) and total hip artrhoplasty with total hip replacement (thr). We conducted a prospective study on a consecutive sample of 280 patients affected by hip or knee OA who underwent total joint replacement. At patients’ admission, Harris Hip Score (HHS) and Knee Society Score (KSS) were used to assess pain and function. Furthermore, SF-36, Mini-Mental Status Examination (MMSE), Symptom Checklist-90-R (SCL-90-R), Coping Orientation to Problems Experienced (BRIEF-COPE) and the Amsterdam Preoperative Anxiety and Information Scale (APAIS) were administered. Patients had clinical and radio graphical follow up at 1, 3 and 6 months post-operatively. The HHS and KSS values before surgery showed a linear correlation with both SCL-90-R and MMSE. None of the investigated variables influenced post-operative HHS and KSS scores; however, the improvement of functional scores resulted conditioned by SCL-90-R values, VAS score, schooling and MMSE. Psychological factors and mental status in primary total hip and knee replacement can affect outcome and patient satisfaction. Strategies focused on identification and facing of these conditions must be considered to improve outcome of total replacement.

  17. Audit on the Efficient Use of Cross-Matched Blood in Elective Total Hip and Total Knee Replacement

    Science.gov (United States)

    Rogers, BA; Johnstone, DJ

    2006-01-01

    INTRODUCTION This prospective audit studies the use of cross-matched blood in 301 patients over a 1-year period undergoing total knee (TKR) and total hip replacement (THR) surgery in an orthopaedic unit. PATIENTS AND METHODS Analysis over the first 6 months revealed a high level of unnecessary cross-matched blood. The following interventions were introduced: (i) to cease routine cross-matching for THR; (ii) all patients to have a check full blood count on day 2 after surgery; and (iii) Hb < 8 g/dl to be considered as the trigger for transfusion in patients over 65 years and free from significant co-morbidity. These changes are in accordance with published national guidelines [Anon. Guidelines for the clinical use of red cell transfusions. Br J Haematol 2001; 113: 24–31]. RESULTS In the next 6 months, the number of units cross-matched but not transfused fell by 96% for THR, and the cross-match transfusion (C:T) ratio reduced from 3.21 to 1.62. Reductions were also observed for the TKR cohort. These results provide evidence of a substantial risk and cost benefit in the use of this limited resource. A telephone survey of 44 hospitals revealed that 20 hospitals routinely cross-matched blood for THR and 11 do so for TKR. CONCLUSIONS Changes can be made to the Maximum Surgical Blood Ordering Schedules (MSBOS) in other orthopaedic units according to national guidelines. PMID:16551419

  18. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  19. Lawsuits After Primary and Revision Total Hip Arthroplasties: A Malpractice Claims Analysis.

    Science.gov (United States)

    Patterson, Diana C; Grelsamer, Ronald P; Bronson, Michael J; Moucha, Calin S

    2017-10-01

    As the prevalence of total hip arthroplasty (THA) expands, so too will complications and patient dissatisfaction. The goal of this study was to identify the common etiologies of malpractice suits and costs of claims after primary and revision THAs. Analysis of 115 malpractice claims filed for alleged neglectful primary and revision THA surgeries by orthopedic surgeons insured by a large New York state malpractice carrier between 1983 and 2011. The incidence of malpractice claims filed for negligent THA procedures is only 0.15% per year in our population. In primary cases, nerve injury ("foot drop") was the most frequent allegation with 27 claims. Negligent surgery causing dislocation was alleged in 18 and leg length discrepancy in 14. Medical complications were also reported, including 3 thromboembolic events and 6 deaths. In revision cases, dislocation and infection were the most common source of suits. The average indemnity payment was $386,153 and the largest single settlement was $4.1 million for an arterial injury resulting in amputation after a primary hip replacement. The average litigation cost to the insurer was $61,833. Nerve injury, dislocation, and leg length discrepancy are the most common reason for malpractice after primary THA. Orthopedic surgeons should continue to focus on minimizing the occurrence of these complications while adequately incorporating details about the risks and limitations of surgery into their preoperative education. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Incidence of delirium in postoperative patients treated with total knee and hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Felipe de Santana Bosmak

    Full Text Available Summary Introduction: Delirium is a common disorder that can potentiate mortality and comorbidity rates of patients hospitalized in intensive care units. Patients undergoing major orthopedic surgeries, such as knee and hip arthroplasty, are particularly vulnerable as they often have multiple risk factors for this disorder. Method: Descriptive study of the incidence of delirium in patients treated with total knee and hip arthroplasty, given the advanced age and comorbidities in this population. We evaluated the medical records of patients who had previously undergone the designated surgeries for identification of postoperative delirium. Results: We observed in this study an incidence of 8.92% of delirium, mostly affecting females with a mean age of 73 years and hypertension. Conclusion: The incidence of delirium in our study is similar to that observed in the general population, according to the literature. We found no correlation with sleep disorders, smoking or diabetes mellitus in this study, even though the importance of these factors for the onset of delirium is well-established in the literature.

  1. Can the pre-operative Western Ontario and McMaster score predict patient satisfaction following total hip arthroplasty?

    Science.gov (United States)

    Rogers, B A; Alolabi, B; Carrothers, A D; Kreder, H J; Jenkinson, R J

    2015-02-01

    In this study we evaluated whether pre-operative Western Ontario and McMaster Universities (WOMAC) osteoarthritis scores can predict satisfaction following total hip arthroplasty (THA). Prospective data for a cohort of patients undergoing THA from two large academic centres were collected, and pre-operative and one-year post-operative WOMAC scores and a 25-point satisfaction questionnaire were obtained for 446 patients. Satisfaction scores were dichotomised into either improvement or deterioration. Scatter plots and Spearman's rank correlation coefficient were used to describe the association between pre-operative WOMAC and one-year post-operative WOMAC scores and patient satisfaction. Satisfaction was compared using receiver operating characteristic (ROC) analysis against pre-operative, post-operative and δ WOMAC scores. We found no relationship between pre-operative WOMAC scores and one-year post-operative WOMAC or satisfaction scores, with Spearman's rank correlation coefficients of 0.16 and -0.05, respectively. The ROC analysis showed areas under the curve (AUC) of 0.54 (pre-operative WOMAC), 0.67 (post-operative WOMAC) and 0.43 (δ WOMAC), respectively, for an improvement in satisfaction. We conclude that the pre-operative WOMAC score does not predict the post-operative WOMAC score or patient satisfaction after THA, and that WOMAC scores can therefore not be used to prioritise patient care. ©2015 The British Editorial Society of Bone & Joint Surgery.

  2. Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

    Science.gov (United States)

    Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa

    2012-08-01

    Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.

  3. Botulinum toxin type A injections for the management of muscle tightness following total hip arthroplasty: a case series

    Directory of Open Access Journals (Sweden)

    Delanois Ronald E

    2009-08-01

    Full Text Available Abstract Background Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty. Methods Ten patients (14 hips who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks. Results At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees. Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points prior to injection to a mean of 96 points (range, 93 to 98 at final follow-up. There were no serious treatment-related adverse events. Conclusion Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.

  4. Clinical usage of indium-111 labeled leukocyte scintigraphy and technetium-99m methylene diphosphonate scintigraphy in patients with total hip replacement

    International Nuclear Information System (INIS)

    Terauchi, Takashi; Uno, Kimiichi; Yuyama, Takuo; Seto, Kazuhiko; Arimizu, Noboru; Suguro, Tohru; Moriya, Hideshige; Uematsu, Sadao.

    1988-01-01

    Tc-99m methylene diphosphonate (MDP) scintigraphy and In-111 labeled leukocyte scintigraphy were done in 13 patients with total hip replacement in order to determine the presence of prosthetic infection. Tc-99m MDP scintigraphy was done in 11 patients (12 studies). In-111 labeled leukocyte scintigraphy was done in 13 patients (14 studies). Tc-99m MDP imaging showed diffuse accumulation of the radionuclide in all of the 3 infected lesions, but focal one in 5 of the 7 noninfected lesions with a specificity of 33.3 %, sensitivity of 100 %, overall accuracy of 50 %. In-111 labeled leukocyte normally accumulates in the spleen, the liver, and the bone marrow. Before insertion of a stemmed prosthesis, the local bone marrows were reamed out in all of our cases. Thus, no radioactive accumulation would be expected in the lesions with prosthesis unless infected. However, if the prosthesis is infected, increased uptake of In-111 would be seen as a result of the accumulation of leukocyte. In-111 labeled leukocyte imaging showed abnormal accumulation of In-111 in all of the 4 infected lesions and no accumulation in all of the 10 noninfected lesions with a specificity of 100 %, sensitivity of 100 %, overall accuracy of 100 %. We conclude that In-111 labeled leukocyte scintigraphy might be useful in evaluating prosthetic infection in a patient with total hip replacement. (author)

  5. Functional exercise after total hip replacement (FEATHER a randomised control trial

    Directory of Open Access Journals (Sweden)

    Monaghan Brenda

    2012-11-01

    Full Text Available Abstract Background Prolonged physical impairments in range of movement, postural stability and walking speed are commonly reported following total hip replacement (THR. It is unclear from the current body of evidence what kind of exercises should be performed to maximize patient function and quality of life. Methods/design This will be a single blind multi centre randomized control trial with two arms. Seventy subjects post primary total hip arthroplasty will be randomized into either an experimental group (n=35, or to a control group (n=35. The experimental group will attend a functional exercise class twice weekly for a six week period from week 12 to week 18 post surgery. The functional exercise group will follow a circuit based functional exercise class supervised by a chartered Physiotherapist. The control group will receive usual care. The principal investigator (BM will perform blinded outcome assessments on all patients using validated measures for pain, stiffness, and function using the Western Ontario and Mc Master Universities Osteoarthritis index (WOMAC. This is the primary outcome measurement tool. Secondary outcome measurements include Quality of life (SF-36, 6 min walk test, Visual Analogue Scale, and the Berg Balance score. The WOMAC score will be collated on day five post surgery and repeated at week twelve and week eighteen. All other measurements will be taken at week 12 and repeated at week eighteen. In addition a blinded radiologist will measure gluteus medius cross sectional area using rea