WorldWideScience

Sample records for total flow compared

  1. Comparative cost analyses: total flow vs other power conversion systems for the Salton Sea Geothermal Resource

    Energy Technology Data Exchange (ETDEWEB)

    Wright, G.W.

    1978-09-18

    Cost studies were done for Total Flow, double flash, and multistage flash binary systems for electric Energy production from the Salton Sea Geothermal Resource. The purpose was to provide the Department of energy's Division of Geothermal Energy with information by which to judge whether to continue development of the Total Flow system. Results indicate that the Total Flow and double flash systems have capital costs of $1,135 and $1,026 /kW with energy costs of 40.9 and 39.7 mills/kW h respectively. The Total Flow and double flash systems are not distinguishable on a cost basis alone; the multistage flash binary system, with capital cost of $1,343 /kW and energy cost of 46.9 mills/kW h, is significantly more expensive. If oil savings are considered in the total analysis, the Total Flow system could save 30% more oil than the double flash system, $3.5 billion at 1978 oil prices.

  2. ANALYSIS AND ACCOUNTING OF TOTAL CASH FLOW

    Directory of Open Access Journals (Sweden)

    MELANIA ELENA MICULEAC

    2012-01-01

    Full Text Available In order to reach the objective of supplying some relevant information regarding the liquidity inflows and outflows during a financial exercise, the total cash flow analysis must include the analysis of result cashable from operation, of payments and receipts related to the investment and of financing decisions of the last exercise, as well as the analysis of treasury variation (of cash items. The management of total cash flows ensures the correlation of current liquidness flows as consequence of receipts with the payments ’flows, in order to provide payment continuity of mature obligations.

  3. Measurement of cerebral blood flow by intravenous xenon-133 technique and a mobile system. Reproducibility using the Obrist model compared to total curve analysis

    DEFF Research Database (Denmark)

    Schroeder, T; Holstein, P; Lassen, N A

    1986-01-01

    and side-to-side asymmetry. Data were analysed according to the Obrist model and the results compared with those obtained using a model correcting for the air passage artifact. Reproducibility was of the same order of magnitude as reported using stationary equipment. The side-to-side CBF asymmetry...... was considerably more reproducible than CBF level. Using a single detector instead of five regional values averaged as the hemispheric flow increased standard deviation of CBF level by 10-20%, while the variation in asymmetry was doubled. In optimal measuring conditions the two models revealed no significant...... differences, but in low flow situations the artifact model yielded significantly more stable results. The present apparatus, equipped with 3-5 detectors covering each hemisphere, offers the opportunity of performing serial CBF measurements in situations not otherwise feasible....

  4. Apparatus for measuring total flow in pipes

    International Nuclear Information System (INIS)

    Matthews, H.

    1986-01-01

    To obtain a sample representative of the total flow in a pipe over a given period a Pitot tube is located in the pipe and connected to a collector outside the pipe. The collector is pressurised to a pressure substantially equal to the static head of the flow in the pipe via a line. Liquid is discharged from a collector to a container which is vented to atmosphere. (author)

  5. Hybrid Continuous-Flow Total Artificial Heart.

    Science.gov (United States)

    Fox, Carson; Chopski, Steven; Murad, Nohra; Allaire, Paul; Mentzer, Robert; Rossano, Joseph; Arabia, Francisco; Throckmorton, Amy

    2018-05-01

    Clinical studies using total artificial hearts (TAHs) have demonstrated that pediatric and adult patients derive quality-of-life benefits from this form of therapy. Two clinically-approved TAHs and other pumps under development, however, have design challenges and limitations, including thromboembolic events, neurologic impairment, infection risk due to large size and percutaneous drivelines, and lack of ambulation, to name a few. To address these limitations, we are developing a hybrid-design, continuous-flow, implantable or extracorporeal, magnetically-levitated TAH for pediatric and adult patients with heart failure. This TAH has only two moving parts: an axial impeller for the pulmonary circulation and a centrifugal impeller for the systemic circulation. This device will utilize the latest generation of magnetic bearing technology. Initial geometries were established using pump design equations, and computational modeling provided insight into pump performance. The designs were the basis for prototype manufacturing and hydraulic testing. The study results demonstrate that the TAH is capable of delivering target blood flow rates of 1-6.5 L/min with pressure rises of 1-92 mm Hg for the pulmonary circulation and 24-150 mm Hg for the systemic circulation at 1500-10 000 rpm. This initial design of the TAH was successful and serves as the foundation to continue its development as a novel, more compact, nonthrombogenic, and effective therapeutic alternative for infants, children, adolescents, and adults with heart failure. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Comparative risk assessment of total energy systems

    International Nuclear Information System (INIS)

    Soerensen, B.

    1982-01-01

    The paper discusses a methodology for total impact assessment of energy systems, ideally evaluating all the impacts that a given energy system has on the society in which it is imbedded or into which its introduction is being considered. Impacts from the entire energy conversion chain ('fuel cycle' if the system is fuel-based), including energy storage, transport and transmission, as well as the institutions formed in order to manage the system, should be compared on the basis of the energy service provided. A number of impacts are considered, broadly classified as impacts on satisfaction of biological needs, on health, on environment, on social relations and on the structure of society. Further considerations include impacts related to cost and resilience, and, last but not least, impacts on global relations. The paper discusses a number of published energy studies in the light of the comparative impact assessment methodology outlined above. (author)

  7. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  8. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy.

    Science.gov (United States)

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-11-01

    Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. From March 2008 to February 2012, 57 selected patients underwent standard or totally tubeless PNL. Neither a nephrostomy tube nor a ureteral stent was placed in the totally tubeless PNL group. We compared patient and stone characteristics, operation time, length of hospitalization, analgesia requirements, stone-free rate, blood loss, change in creatinine, and perioperative complications between the standard and totally tubeless PNL groups. There were no significant differences in preoperative patient characteristics, postoperative complications, or the stone-free rate between the two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with the standard PNL group. Blood loss and change in creatinine were not significantly different between the two groups. Totally tubeless PNL appears to be a safe and effective alternative for the management of renal stone patients and is associated with a decrease in length of hospital stay.

  9. Comparative changes in monthly blood urea nitrogen, total protein ...

    African Journals Online (AJOL)

    The objective of this study was to determine the comparative changes in the monthly blood urea nitrogen (BUN) concentration, total protein (TP) concentration in blood serum and the body condition score of Nguni cows and heifers raised on sweetveld. Twenty-four clinically healthy animals in different parities, namely Parity ...

  10. Batch Scheduling for Hybrid Assembly Differentiation Flow Shop to Minimize Total Actual Flow Time

    Science.gov (United States)

    Maulidya, R.; Suprayogi; Wangsaputra, R.; Halim, A. H.

    2018-03-01

    A hybrid assembly differentiation flow shop is a three-stage flow shop consisting of Machining, Assembly and Differentiation Stages and producing different types of products. In the machining stage, parts are processed in batches on different (unrelated) machines. In the assembly stage, each part of the different parts is assembled into an assembly product. Finally, the assembled products will further be processed into different types of final products in the differentiation stage. In this paper, we develop a batch scheduling model for a hybrid assembly differentiation flow shop to minimize the total actual flow time defined as the total times part spent in the shop floor from the arrival times until its due date. We also proposed a heuristic algorithm for solving the problems. The proposed algorithm is tested using a set of hypothetic data. The solution shows that the algorithm can solve the problems effectively.

  11. The total flow concept for geothermal energy conversion

    Science.gov (United States)

    Austin, A. L.

    1974-01-01

    A geothermal development project has been initiated at the Lawrence Livermore Laboratory (LLL) to emphasize development of methods for recovery and conversion of the energy in geothermal deposits of hot brines. Temperatures of these waters vary from 150 C to more than 300 C with dissolved solids content ranging from less than 0.1% to over 25% by weight. Of particular interest are the deposits of high-temperature/high-salinity brines, as well as less saline brines, known to occur in the Salton Trough of California. Development of this resource will depend on resolution of the technical problems of brine handling, scale and precipitation control, and corrosion/erosion resistant systems for efficient conversion of thermal to electrical energy. Research experience to date has shown these problems to be severe. Hence, the LLL program emphasizes development of an entirely different approach called the Total Flow concept.

  12. Minimizing total weighted completion time in a proportionate flow shop

    NARCIS (Netherlands)

    Shakhlevich, N.V.; Hoogeveen, J.A.; Pinedo, M.L.

    1998-01-01

    We study the special case of the m machine flow shop problem in which the processing time of each operation of job j is equal to pj; this variant of the flow shop problem is known as the proportionate flow shop problem. We show that for any number of machines and for any regular performance

  13. Comparative Study between Standard and Totally Tubeless Percutaneous Nephrolithotomy

    OpenAIRE

    Yun, Sung Il; Lee, Yoon Hyung; Kim, Jae Soo; Cho, Sung Ryong; Kim, Bum Soo; Kwon, Joon Beom

    2012-01-01

    Purpose Several recent studies have reported the benefits of tubeless percutaneous nephrolithotomy (PNL). Postoperatively, tubeless PNL patients have an indwelling ureteral stent placed, which is often associated with stent-related morbidity. We have performed totally tubeless (tubeless and stentless) PNL in which no nephrostomy tube or ureteral stent is placed postoperatively. We evaluated the safety, effectiveness, and feasibility of totally tubeless PNL. Materials and Methods From March 20...

  14. Comparative total phenolic content, anti-lipase and antioxidant ...

    African Journals Online (AJOL)

    Total phenol values are expressed in terms of Gallic acid equivalent (w/w of dry mass). Aframomum melegueta exhibited the highest phenolic content of 60.4 ± 2.36 mgGAE/g, a percentage antioxidant activity of 86.6 % at 200μg/ml and percentage lipase inhibition of 89% at 1mg/ml while Aframomum danielli revealed a total ...

  15. Foundations of Total Functional Data-Flow Programming

    Directory of Open Access Journals (Sweden)

    Baltasar Trancón y Widemann

    2014-06-01

    Full Text Available The field of declarative stream programming (discrete time, clocked synchronous, modular, data-centric is divided between the data-flow graph paradigm favored by domain experts, and the functional reactive paradigm favored by academics. In this paper, we describe the foundations of a framework for unifying functional and data-flow styles that differs from FRP proper in significant ways: It is based on set theory to match the expectations of domain experts, and the two paradigms are reduced symmetrically to a low-level middle ground, with strongly compositional semantics. The design of the framework is derived from mathematical first principles, in particular coalgebraic coinduction and a standard relational model of stateful computation. The abstract syntax and semantics introduced here constitute the full core of a novel stream programming language.

  16. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    International Nuclear Information System (INIS)

    Burcharth, F.; Aagaard, J.; Herlev Hospital

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P [de

  17. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Keum Soo; Choi, Sun Seob; Lee, Young Il [Dong-A Univ., College of Medicine, Busan (Korea, Republic of)

    2001-12-01

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628{+-}68 (range, 517 to 779) ml/min and 612{+-}79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow.

  18. Total hepatofugal portal blood flow in cirrhosis demonstrated by transhepatic portography

    Energy Technology Data Exchange (ETDEWEB)

    Burcharth, F; Aagaard, J

    1988-01-01

    We investigated 108 patients with cirrhosis of the liver and portal hypertension by percutaneous transhepatic portography to demonstrate the occurrence and frequency of total hepatofugal portal blood flow. Sixteen patients (14.8%) had a total hepatofugal portal blood flow. The aetiology of portal hypertension and the portal pressure did not differ from that in the group of patients with hepatopetal portal blood flow. A significantly higher percentage of patients in the group with hepatofugal flow had gastro-oesophageal varices (P < 0.025). All patients with varices had bled. Half of the patients in the group with hepatofugal blood flow had a false splenoportographic diagnosis of portal vein thrombosis. In conclusion, total hepatofugal postal blood flow exists more often than hitherto assumed. Hepatofugal blood flow does not relieve portal hypertension nor prevent development of gastro-oesophageal varices or bleeding.

  19. Comparing and contrasting current guidelines for venous thromboembolism prophylaxis after total hip and total knee arthroplasty.

    Science.gov (United States)

    Lachiewicz, Paul F

    2011-01-01

    Orthopaedic surgeons may be impacted by three different clinical venous thromboembolism guidelines: the American College of Chest Physicians guidelines, the Surgical Care Improvement Project guidelines, and, most recently, the American Academy of Orthopaedic Surgeons (AAOS) guideline. The American College of Chest Physicians guidelines use deep venous thrombosis detected by venography or ultrasonography as their primary outcome measure. High-grade recommendations are based on prospective randomized studies only, usually comparing one pharmacologic agent to another. The Surgical Care Improvement Project guidelines are essentially based on the 2004 American College of Chest Physicians guidelines and seek to determine if surgeons prescribe venous thromboembolism prophylaxis within 24 hours of admission. Compliance with these guidelines may affect the quality rating of a particular hospital. The AAOS guideline was designed with the clinical outcome measures of symptomatic pulmonary embolism, fatal pulmonary embolism, major bleeding, and all-cause mortality. This guideline recommends that surgeons preoperatively evaluate the patient's risks (standard or elevated) for pulmonary embolism and serious bleeding and individualize pharmacologic prophylaxis based on a risk-benefit ratio. The three guidelines all have advantages and disadvantages.

  20. Differences in displayed pump flow compared to measured flow under varying conditions during simulated cardiopulmonary bypass.

    LENUS (Irish Health Repository)

    Hargrove, M

    2008-07-01

    Errors in blood flow delivery due to shunting have been reported to reduce flow by, potentially, up to 40-83% during cardiopulmonary bypass. The standard roller-pump measures revolutions per minute and a calibration factor for different tubing sizes calculates and displays flow accordingly. We compared displayed roller-pump flow with ultrasonically measured flow to ascertain if measured flow correlated with the heart-lung pump flow reading. Comparison of flows was measured under varying conditions of pump run duration, temperature, viscosity, varying arterial\\/venous loops, occlusiveness, outlet pressure, use of silicone or polyvinyl chloride (PVC) in the roller race, different tubing diameters, and use of a venous vacuum-drainage device.

  1. Comparative Measurement of Stream Flow in the Ethiope River for ...

    African Journals Online (AJOL)

    This study investigates comparative measurement of stream flow in the Ethiope River for small hydropower development. Two methods – the Float and Current Meter or Bridge Broom Methods were investigated and values compared to determine best method for optimal power generation. Depth and width measurements ...

  2. Total and regional blood flows in vascularized skeletal muscle grafts in rabbits

    International Nuclear Information System (INIS)

    Burton, H.W.; Stevenson, T.R.; Dysko, R.C.; Gallagher, K.P.; Faulkner, J.A.

    1988-01-01

    The transplantation of whole skeletal muscles is a common clinical procedure. Although atypical blood flows have been reported in small free muscle grafts, the blood flow of large neurovascular-intact (NVI) and neurovascular-anastomosed (NVA) grafts have not been measured. Because the maximum specific force (N/cm 2 ) of NVI and NVA grafts is 65% that of control muscles, we hypothesized that total and regional blood flows of NVI and NVA grafts at rest and during twitch contractions are significantly lower than lower flows of control muscles. In rabbits, blood flows of control rectus femoris (RFM) muscles and NVI and NVA grafts of RFM muscles were measured by the radioactive-microsphere technique. Total blood flows in grafts were not different from the control RFM muscle values, except for a higher resting flow in NVA grafts and a lower flow at 3 Hz in NVI grafts. Minor variations in regional flows were observed. We conclude that the operative procedures of grating and repair of blood vessels affect the vascular bed of muscles minimally, and the deficits observed in grafts do not arise from inadequate perfusion

  3. Dense Descriptors for Optical Flow Estimation: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Ahmadreza Baghaie

    2017-02-01

    Full Text Available Estimating the displacements of intensity patterns between sequential frames is a very well-studied problem, which is usually referred to as optical flow estimation. The first assumption among many of the methods in the field is the brightness constancy during movements of pixels between frames. This assumption is proven to be not true in general, and therefore, the use of photometric invariant constraints has been studied in the past. One other solution can be sought by use of structural descriptors rather than pixels for estimating the optical flow. Unlike sparse feature detection/description techniques and since the problem of optical flow estimation tries to find a dense flow field, a dense structural representation of individual pixels and their neighbors is computed and then used for matching and optical flow estimation. Here, a comparative study is carried out by extending the framework of SIFT-flow to include more dense descriptors, and comprehensive comparisons are given. Overall, the work can be considered as a baseline for stimulating more interest in the use of dense descriptors for optical flow estimation.

  4. Determination of Total Selenium in Infant Formulas: Comparison of the Performance of FIA and MCFA Flow Systems

    Directory of Open Access Journals (Sweden)

    Mariela Pistón

    2012-01-01

    Full Text Available Two flow methods, based, respectively, on flow-injection analysis (FIA and on multicommutated flow analysis (MCFA, were compared with regard to their use for the determination of total selenium in infant formulas by hydride-generation atomic absorption spectrometry. The method based on multicommutation provided lower detection and quantification limits (0.08 and 0.27 μg L−1 compared to 0.59 and 1.95 μ L−1, resp., higher sampling frequency (160 versus. 70 samples per hour, and reduced reagent consumption. Linearity, precision, and accuracy were similar for the two methods compared. It was concluded that, while both methods proved to be appropriate for the purpose, the MCFA-based method exhibited a better performance.

  5. Initial in vitro testing of a paediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader

    2018-06-01

    Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.

  6. A comparative study of the flow enhancing properties of bentonite ...

    African Journals Online (AJOL)

    A comparative study of granule flow enhancing property of bentonite, magnesium stearate, talc and microcrystalline cellulose (MCC) was undertaken. Bentonite was processed into fine powder. A 10 %w/w of starch granules was prepared and separated into different sizes (˂180, 180-500, 500-710 and 710-850 μm).

  7. Transport and flow characteristics of an oscillating cylindrical fiber for total artificial lung application

    KAUST Repository

    Qamar, Adnan; Bull, Joseph L.

    2017-01-01

    Mass transport and fluid dynamics characteristics in the vicinity of an oscillating cylindrical fiber with an imposed pulsatile inflow condition are computationally investigated in the present study. The work is motivated by a recently proposed design modification to the Total Artificial Lung (TAL) device, which is expected to provide better gas exchange. Navier–Stokes computations, coupled with convection–diffusion equation are performed to assess flow dynamics and mass transport behavior around the oscillating fiber. The oscillations and the pulsatile free stream velocity are represented by two sinusoidal functions. The resulting non-dimensional parameters are Keulegan–Carpenter number (KC), Schmidt number (Sc), Reynolds number (Re), pulsatile inflow amplitude (), and amplitude of cylinder oscillation (). Results are computed for , Sc = 1000, Re = 5 and 10, and 0.7 and 0.25 5.25. The pulsatile inflow parameters correspond to the flow velocities found in human pulmonary artery while matching the operating TAL Reynolds number. Mass transport from the surface of the cylinder to the bulk fluid is found to be primarily dependent on the size of surface vortices created by the movement of the cylinder. Time-averaged surface Sherwood number (Sh) is dependent on the amplitude and KC of cylinder oscillation. Compared to the fixed cylinder case, a significant gain up to 380% in Sh is achieved by oscillating the cylinder even at the small displacement amplitude (AD = 0.75D). Moreover, with decrease in KC the oscillating cylinder exhibits a lower drag amplitude compared with the fixed cylinder case. Inflow pulsation amplitude has minor effects on the mass transport characteristics. However, an increase in results in an increase in the amplitude of the periodic drag force on the cylinder. This rise in the drag amplitude is similar to that measured for the fixed cylinder case. Quantifications of shear stress distribution in the bulk fluid suggest that the physiological

  8. Transport and flow characteristics of an oscillating cylindrical fiber for total artificial lung application

    KAUST Repository

    Qamar, Adnan

    2017-06-28

    Mass transport and fluid dynamics characteristics in the vicinity of an oscillating cylindrical fiber with an imposed pulsatile inflow condition are computationally investigated in the present study. The work is motivated by a recently proposed design modification to the Total Artificial Lung (TAL) device, which is expected to provide better gas exchange. Navier–Stokes computations, coupled with convection–diffusion equation are performed to assess flow dynamics and mass transport behavior around the oscillating fiber. The oscillations and the pulsatile free stream velocity are represented by two sinusoidal functions. The resulting non-dimensional parameters are Keulegan–Carpenter number (KC), Schmidt number (Sc), Reynolds number (Re), pulsatile inflow amplitude (), and amplitude of cylinder oscillation (). Results are computed for , Sc = 1000, Re = 5 and 10, and 0.7 and 0.25 5.25. The pulsatile inflow parameters correspond to the flow velocities found in human pulmonary artery while matching the operating TAL Reynolds number. Mass transport from the surface of the cylinder to the bulk fluid is found to be primarily dependent on the size of surface vortices created by the movement of the cylinder. Time-averaged surface Sherwood number (Sh) is dependent on the amplitude and KC of cylinder oscillation. Compared to the fixed cylinder case, a significant gain up to 380% in Sh is achieved by oscillating the cylinder even at the small displacement amplitude (AD = 0.75D). Moreover, with decrease in KC the oscillating cylinder exhibits a lower drag amplitude compared with the fixed cylinder case. Inflow pulsation amplitude has minor effects on the mass transport characteristics. However, an increase in results in an increase in the amplitude of the periodic drag force on the cylinder. This rise in the drag amplitude is similar to that measured for the fixed cylinder case. Quantifications of shear stress distribution in the bulk fluid suggest that the physiological

  9. Comparative study of incompressible and isothermal compressible flow solvers for cavitating flow dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun Ho [Korea Maritime and Ocean University, Busan (Korea, Republic of); Rhee, Shin Hyung [Seoul National University, Seoul (Korea, Republic of)

    2015-08-15

    Incompressible flow solvers are generally used for numerical analysis of cavitating flows, but with limitations in handling compressibility effects on vapor phase. To study compressibility effects on vapor phase and cavity interface, pressure-based incompressible and isothermal compressible flow solvers based on a cell-centered finite volume method were developed using the OpenFOAM libraries. To validate the solvers, cavitating flow around a hemispherical head-form body was simulated and validated against the experimental data. The cavity shedding behavior, length of a re-entrant jet, drag history, and the Strouhal number were compared between the two solvers. The results confirmed that computations of the cavitating flow including compressibility effects improved the reproduction of cavitation dynamics.

  10. Effects of exercise and respiration on blood flow in total cavopulmonary connection

    DEFF Research Database (Denmark)

    Hjortdal, V E; Emmertsen, K; Stenbøg, E

    2003-01-01

    BACKGROUND: Little is known about blood flow and its relationship to respiration during exercise in patients with total cavopulmonary connection (TCPC). METHODS AND RESULTS: We studied 11 patients 12.4+/-4.6 years (mean+/-SD) of age 5.9+/-2.8 years (mean+/-SD) after TCPC operation. Real-time MRI...

  11. Massively parallel data processing for quantitative total flow imaging with optical coherence microscopy and tomography

    Science.gov (United States)

    Sylwestrzak, Marcin; Szlag, Daniel; Marchand, Paul J.; Kumar, Ashwin S.; Lasser, Theo

    2017-08-01

    We present an application of massively parallel processing of quantitative flow measurements data acquired using spectral optical coherence microscopy (SOCM). The need for massive signal processing of these particular datasets has been a major hurdle for many applications based on SOCM. In view of this difficulty, we implemented and adapted quantitative total flow estimation algorithms on graphics processing units (GPU) and achieved a 150 fold reduction in processing time when compared to a former CPU implementation. As SOCM constitutes the microscopy counterpart to spectral optical coherence tomography (SOCT), the developed processing procedure can be applied to both imaging modalities. We present the developed DLL library integrated in MATLAB (with an example) and have included the source code for adaptations and future improvements. Catalogue identifier: AFBT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AFBT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU GPLv3 No. of lines in distributed program, including test data, etc.: 913552 No. of bytes in distributed program, including test data, etc.: 270876249 Distribution format: tar.gz Programming language: CUDA/C, MATLAB. Computer: Intel x64 CPU, GPU supporting CUDA technology. Operating system: 64-bit Windows 7 Professional. Has the code been vectorized or parallelized?: Yes, CPU code has been vectorized in MATLAB, CUDA code has been parallelized. RAM: Dependent on users parameters, typically between several gigabytes and several tens of gigabytes Classification: 6.5, 18. Nature of problem: Speed up of data processing in optical coherence microscopy Solution method: Utilization of GPU for massively parallel data processing Additional comments: Compiled DLL library with source code and documentation, example of utilization (MATLAB script with raw data) Running time: 1,8 s for one B-scan (150 × faster in comparison to the CPU

  12. Comparative study of methods for blood flow measurement within transverse sinuses by using MR

    International Nuclear Information System (INIS)

    Gao Gejun; Feng Xiaoyuan; Yang Bojie; Geng Daoying

    2003-01-01

    Objective: To assess the accuracy of two-dimensional phase contrast (2D-PC) MR method for blood flow measurement within transverse sinuses by comparing this method with cine phase contrast (cine-PC) MR and Doppler in volunteers and patients. Methods: (1) A total of 12 transverse sinuses were examined in 8 healthy volunteers. 2D-PC MR and cine-PC MR were used respectively to measure the transverse area of flow, the flow velocities, and the volumetric flow rates in the same position in every transverse sinus. Paired t-test was used for comparison between the results determined by 2D-PC MR and that determined by cine-PC MR. (2) A total of 6 transverse sinuses were examined in 5 patients who needed operation. 2D-PC MR was used to determine the blood flow velocity of transverse sinus before operation, and Doppler was used to determine the blood flow velocity of the same transverse sinus during operation. The linear regression analysis was used for statistical analysis. Results: (1) Statistical analysis indicated that there were no significant difference among the transverse area of flow (t = -1.106, P = 0.293), the flow velocities (t = 0.262, P = 0.798), and the volumetric flow rates (t = 0.439, P = 0.669) measured by using 2D-PC MR and cine PC MR, respectively. (2) The correlation between flow velocities determined by 2D-PC MR imaging before operation and that determined by Doppler during operation was in excellent agreement (Y-circumflex = 1.303 x + 0.62, r 2 = 0.88). Conclusion: 2D-PC MR may be a practical convenient method for blood flow measurement within transverse sinuses system

  13. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  14. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    International Nuclear Information System (INIS)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  15. An updated fracture-flow model for total-system performance assessment of Yucca Mountain

    International Nuclear Information System (INIS)

    Gauthier, J.H.

    1994-01-01

    Improvements have been made to the fracture-flow model being used in the total-system performance assessment of a potential high-level radioactive waste repository at Yucca Mountain, Nevada. The open-quotes weeps modelclose quotes now includes (1) weeps of varied sizes, (2) flow-pattern fluctuations caused by climate change, and (3) flow-pattern perturbations caused by repository heat generation. Comparison with the original weeps model indicates that allowing weeps of varied sizes substantially reduces the number of weeps and the number of containers contacted by weeps. However, flow-pattern perturbations caused by either climate change or repository heat generation greatly increases the number of containers contacted by weeps. In preliminary total-system calculations, using a phenomenological container-failure and radionuclide-release model, the weeps model predicts that radionuclide releases from a high-level radioactive waste repository at Yucca Mountain will be below the EPA standard specified in 40 CFR 191, but that the maximum radiation dose to an individual could be significant. Specific data from the site are required to determine the validity of the weep-flow mechanism and to better determine the parameters to which the dose calculation is sensitive

  16. An updated fracture-flow model for total-system performance assessment of Yucca Mountain

    International Nuclear Information System (INIS)

    Gauthier, J.H.

    1994-01-01

    Improvements have been made to the fracture-flow model being used in the total-system performance assessment of a potential high-level radioactive waste repository at Yucca Mountain, Nevada. The ''weeps model'' now includes (1) weeps of varied sizes, (2) flow-pattern fluctuations caused by climate change, and (3) flow-pattern perturbations caused by repository heat generation. Comparison with the original weeps model indicates that allowing weeps of varied sizes substantially reduces the number of weeps and the number of containers contacted by weeps. However, flow-pattern perturbations caused by either climate change or repository heat generation greatly increases the number of containers contacted by weeps. In preliminary total-system calculations, using a phenomenological container-failure and radionuclide-release model, the weeps model predicts that radionuclide releases from a high-level radioactive waste repository at Yucca Mountain will be below the EPA standard specified in 40 CFR 191, but that the maximum radiation dose to an individual could be significant. Specific data from the site are required to determine the validity of the weep-flow mechanism and to better determine the parameters to which the dose calculation is sensitive

  17. An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen

    Directory of Open Access Journals (Sweden)

    Jacqueline M. Barnett

    2014-07-01

    Full Text Available We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM to quantify paramagnetic particles (PMPs in immunochromatographic (lateral flow assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format.

  18. A Hybrid Metaheuristic Approach for Minimizing the Total Flow Time in A Flow Shop Sequence Dependent Group Scheduling Problem

    Directory of Open Access Journals (Sweden)

    Antonio Costa

    2014-07-01

    Full Text Available Production processes in Cellular Manufacturing Systems (CMS often involve groups of parts sharing the same technological requirements in terms of tooling and setup. The issue of scheduling such parts through a flow-shop production layout is known as the Flow-Shop Group Scheduling (FSGS problem or, whether setup times are sequence-dependent, the Flow-Shop Sequence-Dependent Group Scheduling (FSDGS problem. This paper addresses the FSDGS issue, proposing a hybrid metaheuristic procedure integrating features from Genetic Algorithms (GAs and Biased Random Sampling (BRS search techniques with the aim of minimizing the total flow time, i.e., the sum of completion times of all jobs. A well-known benchmark of test cases, entailing problems with two, three, and six machines, is employed for both tuning the relevant parameters of the developed procedure and assessing its performances against two metaheuristic algorithms recently presented by literature. The obtained results and a properly arranged ANOVA analysis highlight the superiority of the proposed approach in tackling the scheduling problem under investigation.

  19. Transport and flow characteristics of an oscillating cylindrical fiber for total artificial lung application.

    Science.gov (United States)

    Qamar, Adnan; Bull, Joseph L

    2017-08-01

    Mass transport and fluid dynamics characteristics in the vicinity of an oscillating cylindrical fiber with an imposed pulsatile inflow condition are computationally investigated in the present study. The work is motivated by a recently proposed design modification to the Total Artificial Lung (TAL) device, which is expected to provide better gas exchange. Navier-Stokes computations, coupled with convection-diffusion equation are performed to assess flow dynamics and mass transport behavior around the oscillating fiber. The oscillations and the pulsatile free stream velocity are represented by two sinusoidal functions. The resulting non-dimensional parameters are Keulegan-Carpenter number (KC), Schmidt number (Sc), Reynolds number (Re), pulsatile inflow amplitude ([Formula: see text]), and amplitude of cylinder oscillation ([Formula: see text]). Results are computed for [Formula: see text], Sc = 1000, Re = 5 and 10, [Formula: see text] and 0.7 and 0.25 [Formula: see text][Formula: see text][Formula: see text] 5.25. The pulsatile inflow parameters correspond to the flow velocities found in human pulmonary artery while matching the operating TAL Reynolds number. Mass transport from the surface of the cylinder to the bulk fluid is found to be primarily dependent on the size of surface vortices created by the movement of the cylinder. Time-averaged surface Sherwood number (Sh) is dependent on the amplitude and KC of cylinder oscillation. Compared to the fixed cylinder case, a significant gain up to 380% in Sh is achieved by oscillating the cylinder even at the small displacement amplitude (AD = 0.75D). Moreover, with decrease in KC the oscillating cylinder exhibits a lower drag amplitude compared with the fixed cylinder case. Inflow pulsation amplitude has minor effects on the mass transport characteristics. However, an increase in [Formula: see text] results in an increase in the amplitude of the periodic drag force on the cylinder. This rise in the drag amplitude is

  20. Hemodynamics of a functional centrifugal-flow total artificial heart with functional atrial contraction in goats.

    Science.gov (United States)

    Shiga, Takuya; Shiraishi, Yasuyuki; Sano, Kyosuke; Taira, Yasunori; Tsuboko, Yusuke; Yamada, Akihiro; Miura, Hidekazu; Katahira, Shintaro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2016-03-01

    Implantation of a total artificial heart (TAH) is one of the therapeutic options for the treatment of patients with end-stage biventricular heart failure. There is no report on the hemodynamics of the functional centrifugal-flow TAH with functional atrial contraction (fCFTAH). We evaluated the effects of pulsatile flow by atrial contraction in acute animal models. The goats received fCFTAH that we created from two centrifugal-flow ventricular assist devices. Some hemodynamic parameters maintained acceptable levels: heart rate 115.5 ± 26.3 bpm, aortic pressure 83.5 ± 10.1 mmHg, left atrial pressure 18.0 ± 5.9 mmHg, pulmonary pressure 28.5 ± 9.7 mmHg, right atrial pressure 13.6 ± 5.2 mmHg, pump flow 4.0 ± 1.1 L/min (left) 3.9 ± 1.1 L/min (right), and cardiac index 2.13 ± 0.14 L/min/m(2). fCFTAH with atrial contraction was able to maintain the TAH circulation by forming a pulsatile flow in acute animal experiments. Taking the left and right flow rate balance using the low internal pressure loss of the VAD pumps may be easier than by other pumps having considerable internal pressure loss. We showed that the remnant atrial contraction effected the flow rate change of the centrifugal pump, and the atrial contraction waves reflected the heart rate. These results indicate that remnant atria had the possibility to preserve autonomic function in fCFTAH. We may control fCFTAH by reflecting the autonomic function, which is estimated with the flow rate change of the centrifugal pump.

  1. Forecasting models for flow and total dissolved solids in Karoun river-Iran

    Science.gov (United States)

    Salmani, Mohammad Hassan; Salmani Jajaei, Efat

    2016-04-01

    Water quality is one of the most important factors contributing to a healthy life. From the water quality management point of view, TDS (total dissolved solids) is the most important factor and many water developing plans have been implemented in recognition of this factor. However, these plans have not been perfect and very successful in overcoming the poor water quality problem, so there are a good volume of related studies in the literature. We study TDS and the water flow of the Karoun river in southwest Iran. We collected the necessary time series data from the Harmaleh station located in the river. We present two Univariate Seasonal Autoregressive Integrated Movement Average (ARIMA) models to forecast TDS and water flow in this river. Then, we build up a Transfer Function (TF) model to formulate the TDS as a function of water flow volume. A performance comparison between the Seasonal ARIMA and the TF models are presented.

  2. Aortopulmonary collateral flow quantification by MR at rest and during continuous submaximal exercise in patients with total cavopulmonary connection.

    Science.gov (United States)

    Mkrtchyan, Naira; Frank, Yvonne; Steinlechner, Eva; Calavrezos, Lenika; Meierhofer, Christian; Hager, Alfred; Martinoff, Stefan; Ewert, Peter; Stern, Heiko

    2017-11-06

    Aortopulmonary collateral flow is considered to have significant impact on the outcome of patients with single ventricle circulation and total cavopulmonary connection (TCPC). There is little information on collateral flow during exercise. To quantify aortopulmonary collateral flow at rest and during continuous submaximal exercise in clinical patients doing well with TCPC. Prospective, case controlled. Thirteen patients with TCPC (17 (11-37) years) and 13 age and sex-matched healthy controls (18 (11-38) years). 1.5T; free breathing; phase sensitive gradient echo sequence. Blood flow in the ascending and descending aorta and superior vena cava were measured at rest and during continuous submaximal physical exercise in patients and controls. Systemic blood flow (Q s ) was assumed to be represented by the sum of flow in the superior caval vein (Q svc ) and the descending aorta (Q AoD ) at the diaphragm level. Aortopulmonary collateral flow (Q coll ) was calculated by subtracting Q s from flow in the ascending aorta (Q AoA ). Mann-Whitney U-test and Wilcoxon test for comparison between groups and between rest and exercise. Absolute collateral flow in TCPC patients at rest was 0.4 l/min/m 2 (-0.1-1.2), corresponding to 14% (-2-42) of Q s . Collateral flow did not change during exercise (difference -0.01 (-0.7-1.0) l/min/m 2 , P = 0.97). TCPC patients had significantly lower Q s at rest (2.5 (1.6-4.1) vs. 3.5 (2.6-4.8) l/min/m 2 , P = 0.001) and during submaximal exercise (3.2 (2.0-6.0) vs. 4.8 (3.3-6.9) l/min/m 2 , P = 0.001), compared to healthy controls. The increase in Q s with exercise was also significantly lower in patients than in healthy controls (median 0.6 vs. 1.2 l/min/m 2 , P collateral flow at rest (14% of Q s ) compared to healthy controls, which does not change during submaximal exercise. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Comparative evaluation of PSA-Density, percent free PSA and total PSA

    OpenAIRE

    Ströbel, Greta

    2010-01-01

    BACKGROUND The objective of this study was to evaluate the prostate specific antigen (PSA) density (PSAD) (the quotient of PSA and prostate volume) compared with the percent free PSA (%fPSA) and total PSA (tPSA) in different total PSA (tPSA) ranges from 2 ng/mL to 20 ng/mL. Possible cut-off levels depending on the tPSA should be established. METHODS In total, 1809 men with no pretreatment of the prostate were enrolled between 1996 and 2004. Total and free PSA were measured with t...

  4. Mass flow discharge and total temperature characterisation of a pyrotechnic gas generator formulation for airbag systems

    Energy Technology Data Exchange (ETDEWEB)

    Neutz, Jochen; Koenig, Andreas [Fraunhofer Institut fuer Chemische Technologie ICT, Pfinztal (Germany); Knauss, Helmut; Jordan, Sebastian; Roediger, Tim; Smorodsky, Boris [Universitaet Stuttgart (Germany). Institut fuer Aerodynamik und Gasdynamik; Bluemcke, Erich Walter [AUDI AG, Department I/EK-523, Ingolstadt (Germany)

    2009-06-15

    The mass flow characteristics of gas generators for airbag applications have to comply with a number of requirements for an optimal deployment of the airbag itself. Up to now, the mass flow was determined from pressure time histories of so-called can tests. This procedure suffers from the missing knowledge on the temperature of the generated gas entering the can. A new test setup described in this paper could overcome this problem by providing highly time resolved information on the gas's total temperature and the mass flow of the generator. The test setup consisted of a combustion chamber with a specially designed Laval nozzle in combination with a temperature sensor of high time resolution. The results showed a high time resolved temperature signal, which was disturbed by the formation of a slag layer on the sensor. Plausibility considerations with experimentally and thermodynamically determined combustion temperatures led to satisfying results for the overall temperature as characteristic parameter of airbag inflating gases flows from pyrotechnics. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  5. Determination of total bacterial count in raw milk by flow cytometry

    Directory of Open Access Journals (Sweden)

    Dubravka Samaržija

    2004-01-01

    Full Text Available The automatic flow cytometry as routine method for total bacterial count determination of raw ex-farm milk has recently been accepted in Croatia. This method significantly differs from the reference method (Standard Plate Count mostly in the presentation of the results obtained. Therefore, this paper summarized experiences in the application of flow cytometry in the dairy laboratories practice. The principle and the practice of the method, methodological details and factors influencing the results were described. In order to avoid problems regarding the interpretation of the results, which aregeneral problems of the quantitative microbiology, this article try to explain an appropriate conversion of the results with regards to SPC/ml, as an official method for the bacteriological quality proposal by the national legislation.

  6. Oil flow rate measurements using 198Au and total count technique

    International Nuclear Information System (INIS)

    Goncalves, Eduardo R.; Crispim, Verginia R.

    2013-01-01

    In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and 1/2, 3/4, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198 Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2'x 2', with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud. (author)

  7. Comparative study of total shoulder arthroplasty versus total shoulder surface replacement for glenohumeral osteoarthritis with minimum 2-year follow-up

    NARCIS (Netherlands)

    Kooistra, B.W.; Willems, W.J.H.; Lemmens, E.; Hartel, B.P.; Bekerom, M.P. van den; Deurzen, D.F.P. van

    2017-01-01

    BACKGROUND: Compared with total shoulder arthroplasty (TSA), total shoulder surface replacement (TSSR) may offer the advantage of preservation of bone stock and shorter surgical time, possibly at the expense of glenoid component positioning and increasing lateral glenohumeral offset. We hypothesized

  8. Preliminary assessment of the Velocity Pump Reaction Turbine as a geothermal total-flow expander

    Energy Technology Data Exchange (ETDEWEB)

    Demuth, O.J.

    1985-01-01

    A preliminary evaluation was made of the Velocity Pump Reaction Turbine (VPRT) as a total flow expander in a geothermal-electric conversion cycle. Values of geofluid effectiveness of VPRT systems were estimated for conditions consisting of: a 360/sup 0/F geothermal resource, 60/sup 0/F wet-bulb ambient temperature, zero and 0.003 mass concentrations of dissolved noncondensible gas in the geofluid, 100 and 120/sup 0/F condensing temperature, and engine efficiencies ranging from 0.4 to 1.0. Achievable engine efficiencies were estimated to range from 0.47 to 0.77, with plant geofluid effectivenss values ranging as high as 9.5 Watt hr/lbm geofluid. This value is competitive with magnitudes of geofluid effectiveness projected for advanced binary plants, and is on the order of 40% higher than estimates for dual-flash steam systems and other total flow systems reviewed. Because of its potentially high performance and relative simplicity, the VPRT system appears to warrant further investigation toward its use in a well-head geothermal plant. 13 refs., 5 figs.

  9. Sequential spectrofluorimetric determination of free and total glycerol in biodiesel in a multicommuted flow system

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sidnei G. [Universidade de Sao Paulo, Instituto de Quimica, Sao Paulo (Brazil); Morales-Rubio, Angel; Guardia, Miguel de la [Universidad de Valencia, Department of Analytical Chemistry, Burjassot, Valencia (Spain); Rocha, Fabio R.P. [Universidade de Sao Paulo, Centro de Energia Nuclear na Agricultura, Piracicaba (Brazil)

    2011-07-15

    A new procedure for spectrofluorimetric determination of free and total glycerol in biodiesel samples is presented. It is based on the oxidation of glycerol by periodate, forming formaldehyde, which reacts with acetylacetone, producing the luminescent 3,5-diacetyl-1,4-dihydrolutidine. A flow system with solenoid micro-pumps is proposed for solution handling. Free glycerol was extracted off-line from biodiesel samples with water, and total glycerol was converted to free glycerol by saponification with sodium ethylate under sonication. For free glycerol, a linear response was observed from 5 to 70 mg L{sup -1} with a detection limit of 0.5 mg L{sup -1}, which corresponds to 2 mg kg{sup -1} in biodiesel. The coefficient of variation was 0.9% (20 mg L{sup -1}, n = 10). For total glycerol, samples were diluted on-line, and the linear response range was 25 to 300 mg L{sup -1}. The detection limit was 1.4 mg L{sup -1} (2.8 mg kg{sup -1} in biodiesel) with a coefficient of variation of 1.4% (200 mg L{sup -1}, n = 10). The sampling rate was ca. 35 samples h{sup -1} and the procedure was applied to determination of free and total glycerol in biodiesel samples from soybean, cottonseed, and castor beans. (orig.)

  10. Comparative responsiveness of measures of pain and function after total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A K; Roos, Ewa M.; Westerlund, J P

    2001-01-01

    To compare the responsiveness of the Functional Assessment System (FAS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Medical Outcomes Study 36-item Short Form (SF-36) in patients with osteoarthritis (OA) scheduled for total hip replacement....

  11. Turbidimetric and photometric determination of total tannins in tea using a micro-flow-batch analyzer.

    Science.gov (United States)

    Lima, Marcelo B; Andrade, Stéfani I E; Harding, David P; Pistonesi, Marcelo F; Band, Beatriz S F; Araújo, Mário C U

    2012-01-15

    Both turbidimetric and photometric determinations of total tannins in samples of green and black tea, using a micro-flow-batch analyzer (μFBA) were studied. The miniaturized system was formed using photocurable urethane-acrylate resin and ultraviolet lithography technique. The turbidimetric method was based on the precipitation reaction of Cu (II) with tannins in acetate medium at a pH of 4.5. The photometric method was based on the complexation reaction of tannins with ferrous tartrate. The turbidimetric μFBA was able to test 200 samples per hour. The photometric μFBA allowed 300 analyses per hour, generating 136μL of residue per analysis. The paired t test, at a 95% confidence level, showed no statistically significant differences between results obtained by both methods and the reference method. The urethane-acrylate μFBA maintained satisfactory physical and chemical properties, and represents an improvement over conventional flow-batch analyzer. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader

    2017-12-01

    The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.

  13. Comparing 30-day all-cause readmission rates between tibiotalar fusion and total ankle replacement.

    Science.gov (United States)

    Merrill, Robert K; Ferrandino, Rocco M; Hoffman, Ryan; Ndu, Anthony; Shaffer, Gene W

    2018-01-12

    End-stage ankle arthritis is a debilitating condition that negatively impacts patient quality of life. Tibiotalar fusion and total ankle replacement are treatment options for managing ankle arthritis. Few studies have examined short term readmission rates of these two procedures. The objective of this study was compare all-cause 30-day readmission rates between patients undergoing tibiotalar fusion vs. total ankle replacement. This study queried the Nationwide Readmission Database (NRD) from 2013-2014 and used international classification of disease, 9th revision (ICD-9) procedure codes to identify all patients who underwent a tibiotalar fusion or a total ankle replacement. Comorbidities, insurance status, hospital characteristics, and readmission rates were statistically compared between the two cohorts. Risk factors were then identified for 30-day readmission. A total of 5660 patients were analyzed with 2667 in the tibiotalar fusion cohort and 2993 in the total ankle replacement cohort. Univariate analysis revealed that the readmission rate after tibiotalar fusion (4.4%) was statistically greater than after total ankle replacement (1.4%). Multivariable regression analysis indicated that deficiency anemia (OR 2.18), coagulopathy (OR 3.51), renal failure (OR 2.83), other insurance relative to private (OR 3.40), and tibiotalar fusion (OR 2.51) were all statistically significant independent risk factors for having a readmission within 30-days. These findings suggest that during the short-term period following discharge from the hospital, patients who received a tibiotalar fusion are more likely to experience a 30-day readmission. These findings are important for decision making when a surgeon encounters a patient with end stage ankle arthritis. Level III, cohort study. Published by Elsevier Ltd.

  14. Unilateral vs one stage bilateral total knee replacement in rheumatoid and osteoarthritis - A comparative study

    Directory of Open Access Journals (Sweden)

    Kiran E

    2005-01-01

    Full Text Available Background : A controversy exists regarding simultaneous or staged bilateral total knee replacement. Methods: Fifty patients undergoing simultaneous bilateral and 50 undergoing unilateral total knee arthroplasty were evaluated prospectively to compare the clinical, radiological results and complication rates. Eighty-four patients belonged to ASA category II or III preoperatively. The study included a high proportion of rheumatoid patients and osteoarthritis patients with severe deformities. Results: Bilateral group had greater blood loss and required more blood transfusion, but there was no difference in requirement of postoperative intensive care and the complication rates. Rheumatoid knees had lower pre and postoperative knee score and functional score as compared to osteoarthritic knees. Morbidity and mortality of one stage bilateral knee replacement was no greater than unilateral operation. Conclusion: Simultaneous bilateral knee replacement in younger patients with advanced rheumatoid arthritis is safe and effective

  15. Comparing contact and immersion freezing from continuous flow diffusion chambers

    Directory of Open Access Journals (Sweden)

    B. Nagare

    2016-07-01

    process that is enhanced compared to immersion freezing due to the position of the INP on the droplet, and we discriminate it from collisional contact freezing, which assumes an enhancement due to the collision of the particle with the droplet. For best comparison with contact freezing results, immersion freezing experiments of the same INPs were performed with the continuous flow diffusion chamber Immersion Mode Cooling chAmber–Zurich Ice Nucleation Chamber (IMCA–ZINC for a 3 s residence time. In IMCA–ZINC, each INP is activated into a droplet in IMCA and provides its surface for ice nucleation in the ZINC chamber. The comparison of contact and immersion freezing results did not confirm a general enhancement of freezing efficiency for contact compared with immersion freezing experiments. For AgI particles the onset of heterogeneous freezing in CLINCH was even shifted to lower temperatures compared with IMCA–ZINC. For ATD, freezing efficiencies for contact and immersion freezing experiments were similar. For kaolinite particles, contact freezing became detectable at higher temperatures than immersion freezing. Using contact angle information between water and the INP, it is discussed how the position of the INP in or on the droplets may influence its ice nucleation activity.

  16. Estimation of salivary flow rate, pH, buffer capacity, calcium, total protein content and total antioxidant capacity in relation to dental caries severity, age and gender.

    Science.gov (United States)

    Pandey, Pallavi; Reddy, N Venugopal; Rao, V Arun Prasad; Saxena, Aditya; Chaudhary, C P

    2015-03-01

    The aim of the study was to evaluate salivary flow rate, pH, buffering capacity, calcium, total protein content and total antioxidant capacity in relation to dental caries, age and gender. The study population consisted of 120 healthy children aged 7-15 years that was further divided into two groups: 7-10 years and 11-15 years. In this 60 children with DMFS/dfs = 0 and 60 children with DMFS/dfs ≥5 were included. The subjects were divided into two groups; Group A: Children with DMFS/dfs = 0 (caries-free) Group B: Children with DMFS/dfs ≥5 (caries active). Unstimulated saliva samples were collected from all groups. Flow rates were determined, and samples analyzed for pH, buffer capacity, calcium, total protein and total antioxidant status. Salivary antioxidant activity is measured with spectrophotometer by an adaptation of 2,2'-azino-di-(3-ethylbenzthiazoline-6-sulphonate) assays. The mean difference of the two groups; caries-free and caries active were proved to be statistically significant (P salivary calcium, total protein and total antioxidant level for both the sexes in the age group 7-10 years and for the age 11-15 years the mean difference of the two groups were proved to be statistically significant (P salivary calcium level for both the sexes. Salivary total protein and total antioxidant level were proved to be statistically significant for male children only. In general, total protein and total antioxidants in saliva were increased with caries activity. Calcium content of saliva was found to be more in caries-free group and increased with age.

  17. Early in vivo experience with the pediatric continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka

    2018-03-30

    Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  18. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  19. A Comparative Evaluation of the Flow and Compaction ...

    African Journals Online (AJOL)

    Patrick Erah

    study was to evaluate the suitability of α-cellulose obtained from waste paper as a direct compression excipient. Method: The flow and compaction ... The continuous search for affordable locally available pharmaceutical raw .... and irregular primary particle. These features of the latter could result to formation of bridges and.

  20. A Comparative Evaluation of the Flow and Compaction ...

    African Journals Online (AJOL)

    Purpose: Alpha-cellulose obtained as pulp from fibrous plant materials has found use in the pharmaceutical industry as a disintegrant and direct compression diluent. The aim of this study was to evaluate the suitability of α-cellulose obtained from waste paper as a direct compression excipient. Method: The flow and ...

  1. Comparing groundwater recharge and base flow in the Bukmoongol ...

    Indian Academy of Sciences (India)

    model, also known as the Rorabaugh Method. (Rorabaugh 1960; Daniel 1976; Rutledge 2007b), estimates groundwater recharges for each stream- flow peak using the recession-curve-displacement method. It is based on an analytical model that describes groundwater discharge subsequent to recharge to the water table ...

  2. Histopathology Image Analysis in Two Long-Term Animal Experiments with Helical Flow Total Artificial Heart.

    Science.gov (United States)

    Wotke, Jiri; Homolka, Pavel; Vasku, Jaromír; Dobsak, Petr; Palanova, Petra; Mrkvicova, Veronika; Konecny, Petr; Soska, Vladimir; Pohanka, Michal; Novakova, Marie; Yurimoto, Terumi; Saito, Itsuro; Inoue, Yusuke; Isoyama, Takashi; Abe, Yusuke

    2016-12-01

    Histopathological analysis can provide important information in long-term experiments with total artificial heart (TAH). Recently, a new type of blood pump, the helical flow total artificial heart (HF-TAH) was developed. This study aimed to investigate the changes in selected vital organs in animal experiments with implanted HF-TAH. Samples from lung, liver, and kidneys from two female goats (No. 1301 and No. 1304) with implanted HF-TAH were analyzed. Tissue samples were fixed in 10% formaldehyde and 4 µm thick transverse sections were stained with hematoxylin-eosin (HE). Additional staining was done for detection of connective tissue (Masson-Goldner stain) and for detection of iron (hemosiderin) deposits (Perls stain). Sections were scanned at 100× and 500× magnification with a light microscope. Experiment no. 1301 survived 100 days (cause of termination was heavy damage of the right pump); experimental goat no.1304 survived 68 days and was sacrificed due to severe right hydrodynamic bearing malfunction. Histopathological analysis of liver samples proved signs of chronic venostasis with limited focal necrotic zones. Dilated tubules, proteinaceous material in tubular lumen, and hemosiderin deposits were detected in kidney samples. Contamination of the organs by embolized micro-particles was suspected at the autopsy after discovery of visible damage (scratches) of the pump impeller surface (made from titanium alloy) in both experiments. Sporadic deposits of foreign micro-particles (presumably titanium) were observed in most of the analyzed parenchymal organs. However, the described deposits were not in direct connection with inflammatory reactions in the analyzed tissues. Histopathological analysis showed the presence of minimal contamination of the lung, kidney, and liver tissue samples by foreign material (titanium very likely). The analysis showed only limited pathological changes, especially in liver and kidneys, which might be attributed to the influence of

  3. Estimation of salivary glucose, salivary amylase, salivary total protein and salivary flow rate in diabetics in India.

    Science.gov (United States)

    Panchbhai, Arati S; Degwekar, Shirish S; Bhowte, Rahul R

    2010-09-01

    Diabetes is known to influence salivary composition and function, eventually affecting the oral cavity. We thus evaluated saliva samples for levels of glucose, amylase and total protein, and assessed salivary flow rate in diabetics and healthy non-diabetics. We also analyzed these parameters with regard to duration and type of diabetes mellitus and gender, and aimed to assess the interrelationships among the variables included in the study. A total of 120 age- and sex-matched participants were divided into 3 groups of 40 each; the uncontrolled diabetic group, the controlled diabetic group and the healthy non-diabetic group. Salivary investigations were performed using unstimulated whole saliva. Mean salivary glucose levels were found to be significantly elevated in both uncontrolled and controlled diabetics, as compared to healthy non-diabetics. There were significant decreases in mean salivary amylase levels in controlled diabetics when compared to healthy non-diabetics. Other than salivary glucose, no other parameters were found to be markedly affected in diabetes mellitus. Further research is needed to explore the clinical implications of these study results.

  4. Water cut measurement of oil–water flow in vertical well by combining total flow rate and the response of a conductance probe

    International Nuclear Information System (INIS)

    Chen, Jianjun; Xu, Lijun; Cao, Zhang; Zhang, Wen; Liu, Xingbin; Hu, Jinhai

    2015-01-01

    In this paper, a conductance probe-based well logging instrument was developed and the total flow rate is combined with the response of the conductance probe to estimate the water cut of the oil–water flow in a vertical well. The conductance probe records the time-varying electrical characteristics of the oil–water flow. Linear least squares regression (LSR) and nonlinear support vector regression (SVR) were used to establish models to map the total flow rate and features extracted from the probe response onto the water cut, respectively. Principal component analysis (PCA) and partial least squares analysis (PLSA) techniques were employed to reduce data redundancy within the extracted features. An experiment was carried out in a vertical pipe with an inner diameter of 125 mm and a height of 24 m in an experimental multi-phase flow setup, Daqing Oilfield, China. In the experiment, oil–water flow was used and the total flow rate varied from 10 to 200 m 3 per day and the water cut varied from 0% to 100%. As a direct comparison, the cases were also studied when the total flow rate was not used as an independent input to the models. The results obtained demonstrate that: (1) the addition of the total flow rate as an input to the regression models can greatly improve the accuracy of water cut prediction, (2) the nonlinear SVR model performs much better than the linear LSR model, and (3) for the SVR model with the total flow rate as an input, the adoption of PCA or PLSA not only decreases the dimensions of inputs, but also increases prediction accuracy. The SVR model with five PCA-treated features plus the total flow rate achieves the best performance in water cut prediction, with a coefficient of determination (R 2 ) as high as 0.9970. The corresponding root mean squared error (RMSE) and mean quoted error (MQE) are 0.0312% and 1.99%, respectively. (paper)

  5. Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart

    Science.gov (United States)

    Karimov, Jamshid H.; Steffen, Robert J.; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Cruz, Vincent; Golding, Leonard A.R.; Fukamachi, Kiyotaka; Moazami, Nader

    2015-01-01

    Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m2 (range, 1.6-2.1 m2). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels. PMID:25806613

  6. Comparative study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels

    Directory of Open Access Journals (Sweden)

    Mikielewicz Dariusz

    2014-09-01

    Full Text Available In the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation of the so called blowing parameter. The shear stress between vapor phase and liquid phase is generally a function of nonisothermal effects. The mechanism of modification of shear stresses at the vapor-liquid interface has been presented in detail. In case of annular flow it contributes to thickening and thinning of the liquid film, which corresponds to condensation and boiling respectively. There is also a different influence of heat flux on the modification of shear stress in the bubbly flow structure, where it affects bubble nucleation. In that case the effect of applied heat flux is considered. As a result a modified form of the two-phase flow multiplier is obtained, in which the nonadiabatic effect is clearly pronounced.

  7. Comparing a Shipping Information Pipeline with a Thick Flow and a Thin Flow

    NARCIS (Netherlands)

    van Engelenburg, S.H.; Janssen, M.F.W.H.A.; Klievink, A.J.; Tan, Y.; Janssen, Marijn; Axelsson, Karin; Glassey, Olivier; Klievink, Bram; Krimmer, Robert; Lindgren, Ida; Parycek, Peter; Scholl, Hans J.; Trutnev, Dmitrii

    2017-01-01

    Advanced architectures for business-to-government (B2G) information sharing can benefit both businesses and government. An essential choice in the design of such an architecture is whether information is shared using a thick or a thin information flow. In an architecture with a thick flow, all

  8. A prospective randomised trial comparing mesh types and fixation in totally extraperitoneal inguinal hernia repairs.

    Science.gov (United States)

    Cristaudo, Adam; Nayak, Arun; Martin, Sarah; Adib, Reza; Martin, Ian

    2015-05-01

    The totally extraperitoneal (TEP) approach for surgical repair of inguinal hernias has emerged as a popular technique. We conducted a prospective randomised trial to compare patient comfort scores using different mesh types and fixation using this technique. Over a 14 month period, 146 patients underwent 232 TEP inguinal hernia repairs. We compared the comfort scores of patients who underwent these procedures using different types of mesh and fixation. A non-absorbable 15 × 10 cm anatomical mesh fixed with absorbable tacks (Control group) was compared with either a non-absorbable 15 × 10 cm folding slit mesh with absorbable tacks (Group 2), a partially-absorbable 15 × 10 cm mesh with absorbable tacks (Group 3) or a non-absorbable 15 × 10 cm anatomical mesh fixed with 2 ml fibrin sealant (Group 4). Outcomes were compared at 1, 2, 4 and 12 weeks using the Carolina Comfort Scale (CCS) scores. At 1, 2, 4 and 12 weeks, the median global CCS scores were low for all treatment groups. Statistically significant differences were seen only for median CCS scores and subscores with the use of partially-absorbable mesh with absorbable tacks (Group 3) at weeks 2 and 4. However, these were no longer significant at week 12. In this study, the TEP inguinal hernia repair with minimal fixation results in low CCS scores. There were no statistical differences in CCS scores when comparing types of mesh, configuration of the mesh or fixation methods. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  9. A comparative study of total quality management of health care system in India and Iran

    Directory of Open Access Journals (Sweden)

    Heidari Gorji Ali

    2011-12-01

    Full Text Available Abstract Background Total quality management (TQM has a great potential to address quality problems in a wide range of industries and improve the organizational performance. The growing need to take initiatives by hospitals in countries like India and Iran to improve the service quality and reduce wastage of resources has inspired the authors to develop a survey instrument to measure health care quality and performance in the two countries. Methods Based on the Baldrige health care criteria for performance excellence 2009-2010 and the guidelines proposed by the American Hospitals Association for hospitals in pursuit of excellence, compared health care services in three countries. The data are collected from the capital cities and their nearby places in India and Iran. Using ANOVAs, three groups in quality planning and performance have been compared. Result Results showed there is significantly difference between groups and in no case the hospitals from India and Iran are found scoring close to the benchmarks. The average scores of Indian and Iranian hospitals on different constructs of the IHCQPM model are compared with the major results achieved by the recipients of the MBNQ award. Conclusion In no case the hospitals from India and Iran are found scoring close to the benchmarks (Baldrige health care criteria for performance excellence 2009-2010 and the guidelines proposed by the American Hospitals Association for hospitals. These results suggested to health care services more attempt to achieve high quality in management and performance.

  10. A comparative study of total quality management of health care system in India and Iran.

    Science.gov (United States)

    Heidari Gorji, Ali Morad; Farooquie, Jamal A

    2011-12-28

    Total quality management (TQM) has a great potential to address quality problems in a wide range of industries and improve the organizational performance. The growing need to take initiatives by hospitals in countries like India and Iran to improve the service quality and reduce wastage of resources has inspired the authors to develop a survey instrument to measure health care quality and performance in the two countries. Based on the Baldrige health care criteria for performance excellence 2009-2010 and the guidelines proposed by the American Hospitals Association for hospitals in pursuit of excellence, compared health care services in three countries. The data are collected from the capital cities and their nearby places in India and Iran. Using ANOVAs, three groups in quality planning and performance have been compared. Results showed there is significantly difference between groups and in no case the hospitals from India and Iran are found scoring close to the benchmarks. The average scores of Indian and Iranian hospitals on different constructs of the IHCQPM model are compared with the major results achieved by the recipients of the MBNQ award. In no case the hospitals from India and Iran are found scoring close to the benchmarks (Baldrige health care criteria for performance excellence 2009-2010 and the guidelines proposed by the American Hospitals Association for hospitals). These results suggested to health care services more attempt to achieve high quality in management and performance.

  11. [Interscalene block for total shoulder arthroplasty: comparative study (ultrasound vs. neurostimulation)].

    Science.gov (United States)

    Mejía-Terrazas, Gabriel Enrique; Ruiz-Suárez, Michell; Gaspar-Carrillo, Sandra Patricia; Valero-González, Fernando; Unzueta-Navarro, David; Encalada-Díaz, Iván

    2014-01-01

    Modern anesthesiology has integrated the use of ultrasonography as a tool that has displaced neurostimulation as a technique for locating peripheral nerves. The aim of this study was to determine which procedure is more effective for guiding interscalene block for total shoulder arthroplasty. We carried out a comparative, prospective non-randomized study comprised of the group guided by neurostimulation interscalene block and the group guided by ultrasound. All patients in both groups were scheduled for total shoulder arthroplasty. Latency, degree of sensory and motor block, success rate, postoperative pain intensity at 6, 12, and 24 h, patient satisfaction and complications were measured. We included 110 patients, 55 per group. Patients were placed in beach chair position and the deltopectoral approach was used. There were no differences in demographic characteristics. Results for neurostimulation vs. ultrasound group: latency 19.11 ± 2.27 vs. 17.24 ± 1.42 min, p= 0.23. Block sensitivity in both groups was grade 0 motor block grade 0 in 76.4% and grade 1 in 23.6% vs. grade 0 to 100%. There was 100% success rate for both groups. Postoperative pain at 6 h was 0.13 ± 0.54 vs. 0.11 ± 0.13 p= 0.90, at 12 h 1.67 ± 1.15 vs. 1.65 ± 0.59 p= 0.89 and at 24 h 3.15 ± 1.66 vs. 2.99 ± 1.15 p= 0.78. Satisfaction 54.5% very satisfied and 45.5% satisfied 96.36% vs 3.6% very satisfied and satisfied. Complications 18.18% vs. 3.6% p= 0.023. Ultrasound-guided interscalene nerve block is the technique of choice in elective total shoulder arthroplasty.

  12. Comparative study of topical vs. intravenous tranexamic acid regarding blood loss in total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Ari Zekcer

    Full Text Available ABSTRACT Objective: To compare topical vs. intravenous tranexamic acid (TA in total knee arthroplasty regarding blood loss and transfusion., Methods: Ninety patients were randomized to receive TA intravenously (20 mg/kg in 100 mL of saline; group IV, topically (1.5 g in 50 mL of saline, sprayed over the operated site, before release of the tourniquet; topical group, or intravenous saline (100 mL with anesthesia; control group. The volume of drained blood in 48, h, the amount of transfused blood, and the serum levels of hemoglobin and hematocrit before and after surgery were evaluated., Results: The groups were similar for gender, age, weight, laterality, and preoperative hemoglobin and hematocrit levels (p> 0.2. The hemoglobin level dropped in all groups when comparing the preoperative and the 48-h evaluations: the control group decreased 3.8 mg/dL on average, while the IV, group had a decrease of 3.0, and the topical group, of 3.2 (p= 0.019. The difference between the control and IV, groups was confirmed by Bonferroni test (p= 0.020. The difference between the control group and the topical group was not significant (p= 0.130, although there was less reduction in hemoglobin in the topical group; the comparison between the IV, group and the topical group was also not significant (p= 1.000. Conclusion: Using topic and IV, tranexamic acid decreased blood loss and the need for transfusion in total knee arthroplasty. Topical application showed results similar to IV use regarding the need for blood transfusion, but without the possible side effects of IV, administration.

  13. Comparative study of conventional therapy and additional yogasanas for knee rehabilitation after total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Nilima Bedekar

    2012-01-01

    Full Text Available Background: Amongst various modalities of post operative rehabilitation in a total knee replacement (TKR surgery, this study focuses on evaluating the effect of additional yoga therapy on functional outcome of TKR patients. Materials and Methods: A comparative study was done to compare the effects of conventional physiotherapy and additional yoga asanas, on 56 patients undergoing total knee arthroplasty due to osteoarthritis. After obtaining written informed consent, the patients were alternately assigned to two groups: Conventional and experimental. Baseline WOMAC scores for pain and stiffness were taken on third post operative day. The subjects in conventional group received physiotherapy rehabilitation program of Sancheti Institute where the study was conducted, the experimental group received additional modified yoga asanas once daily by the therapist. After discharge from the hospital, patients were provided with written instructions and photographs of the asanas, two sets of WOMAC questionnaire with stamped and addressed envelopes and were instructed to perform yoga asanas 3 days/week. Subjects filled the questionnaire after 6 weeks and 3 months from the day of surgery and mailed back. The primary outcome measure was WOMAC questionnaire which consists of 24 questions, each corresponding to a visual analog scale, designed to measure patient′s perception of pain, stiffness and function. Results: The results suggest that there was a significant change (P<0.05 for all the groups for pain, stiffness and function subscales of WOMAC scale. The pain and stiffness was found to be less in experimental group receiving additional yoga therapy than in conventional group on 3 rd post operative day, 6 weeks and 3 months after the surgery. Conclusion: A combination of physiotherapy and yoga asana protocol works better than only physiotherapy protocol. Larger and blinded study is needed.

  14. An innovative, sensorless, pulsatile, continuous-flow total artificial heart: device design and initial in vitro study.

    Science.gov (United States)

    Fukamachi, Kiyotaka; Horvath, David J; Massiello, Alex L; Fumoto, Hideyuki; Horai, Tetsuya; Rao, Santosh; Golding, Leonard A R

    2010-01-01

    We are developing a very small, innovative, continuous-flow total artificial heart (CFTAH) that passively self-balances left and right pump flows and atrial pressures without sensors. This report details the CFTAH design concept and our initial in vitro data. System performance of the CFTAH was evaluated using a mock circulatory loop to determine the range of systemic and pulmonary vascular resistance (SVR and PVR) levels over which the design goal of a maximum absolute atrial pressure difference of 10 mm Hg is achieved for a steady-state flow condition. Pump speed was then modulated at 2,600 +/- 900 rpm to induce flow and arterial pressure pulsation to evaluate the effects of speed pulsations on the system performance. An automatic control mode was also evaluated. Using only passive self-regulation, pump flows were balanced and absolute atrial pressure differences were maintained at mode adjusted pump speed to achieve targeted pump flows based on sensorless calculations of SVR and CFTAH flow. The initial in vitro testing of the CFTAH with a single, valveless, continuous-flow pump demonstrated its passive self-regulation of flows and atrial pressures and a new automatic control mode. Copyright (c) 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  15. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing.

  16. Plasma and salivary total antioxidant capacity in healthy controls compared with aggressive and chronic periodontitis patients.

    Science.gov (United States)

    Baser, Ulku; Gamsiz-Isik, Hikmet; Cifcibasi, Emine; Ademoglu, Evin; Yalcin, Funda

    2015-07-01

    To evaluate the plasma and salivary total antioxidant capacity (TAOC) in patients with generalized chronic periodontitis (CP), generalized aggressive periodontitis (AgP), and periodontally healthy controls. This cross-sectional study includes of 88 individuals seeking dental treatment at the Faculty of Dentistry, Istanbul University, Istanbul, Turkey between January 2011 and March 2012. Fifteen AgP patients were compared with 21 healthy controls (C1), while 36 CP patients were compared with 16 healthy controls (C2). Clinical periodontal measurements were recorded, and plasma and saliva samples were collected. The TAOC of the plasma and saliva samples were determined using a commercially available colorimetric kit. The plasma TAOC of both AgP and CP patients was significantly lower for C1 and C2. The salivary TAOC of CP patients was significantly lower for C2, but there was no significant difference between AgP patients and C1. Our results demonstrate that severe periodontitis may be associated with a lower plasma antioxidant capacity. The reduced antioxidant capacity in patients with severe periodontitis, especially with aggressive forms may be an important contributing factor to severe tissue destruction.

  17. Predictors for better blood-flow restoration of long-segmental below-the-knee chronic total occlusions after endovascular therapy in diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Song, Xiao Li [Dept. of Radiology, Chonnam National University Medical School, Gwangju (Korea, Republic of); Zhu, Yue Qi; Lu, Hai Tao; Lui, Fang; Wei, Li Ming; Kang, Heoung Keun; Zhao, Jun Gong [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Shanghai (China)

    2016-11-15

    To prospectively investigate predictors for good restoration of blood flow of below-the-knee (BTK) chronic total occlusions (CTOs) after endovascular therapy in diabetes mellitus (DM) patients. A total of 120 long-segmental (≥ 5 cm) BTK, CTOs in 81 patients who underwent recanalization were included in this study. After angioplasty, blood-flow restoration was assessed using modified thrombolysis in myocardial ischemia grades and classified as good flow (grade 3) and poor flow (grade 1/2). One hundred and six CTOs with successful recanalization were divided into a good flow group (GFG; n = 68) and poor flow group (PFG; n = 38). Multivariate logistic regression analyses were undertaken to determine independent predictors of blood-flow restoration. Receiver operating characteristic curves were constructed to determine the best cutoff value. The prevalence of target-lesion restenosis during follow-up was compared between two groups. Univariate analyses suggested that CTOs in GFG were characterized by lighter limb ischemia (p = 0.03), shorter course of ischemic symptoms (p < 0.01) and lesion length (p = 0.04), more frequent use of intraluminal angioplasty (p = 0.03), and higher runoff score (p < 0.01) than those in PFG. Multivariate regression analyses suggested that distal runoffs (p = 0.001; odds ratio [OR], 10.32; 95% confidence interval [CI]: 4.082-26.071) and lesion length (p < 0.001; OR, 1.26; 95% CI: 1.091-1.449) were independent predictors for good flow restoration. Kaplan-Meier analyses at 12 months showed a higher prevalence of non-restenosis in GFG (p < 0.01). Distal runoffs and lesion length are independent predictors for good flow restoration for long-segmental BTK, CTOs in DM patients who receive endovascular therapy.

  18. Comparative methane estimation from cattle based on total CO2 production using different techniques

    Directory of Open Access Journals (Sweden)

    Md N. Haque

    2017-06-01

    Full Text Available The objective of this study was to compare the precision of CH4 estimates using calculated CO2 (HP by the CO2 method (CO2T and measured CO2 in the respiration chamber (CO2R. The CO2R and CO2T study was conducted as a 3 × 3 Latin square design where 3 Dexter heifers were allocated to metabolic cages for 3 periods. Each period consisted of 2 weeks of adaptation followed by 1 week of measurement with the CO2R and CO2T. The average body weight of the heifer was 226 ± 11 kg (means ± SD. They were fed a total mixed ration, twice daily, with 1 of 3 supplements: wheat (W, molasses (M, or molasses mixed with sodium bicarbonate (Mbic. The dry mater intake (DMI; kg/day was significantly greater (P < 0.001 in the metabolic cage compared with that in the respiration chamber. The daily CH4 (L/day emission was strongly correlated (r = 0.78 between CO2T and CO2R. The daily CH4 (L/kg DMI emission by the CO2T was in the same magnitude as by the CO2R. The measured CO2 (L/day production in the respiration chamber was not different (P = 0.39 from the calculated CO2 production using the CO2T. This result concludes a reasonable accuracy and precision of CH4 estimation by the CO2T compared with the CO2R.

  19. Total hip arthroplasty outcomes assessment using functional and radiographic scores to compare canine systems.

    Science.gov (United States)

    Iwata, D; Broun, H C; Black, A P; Preston, C A; Anderson, G I

    2008-01-01

    A retrospective multi-centre study was carried out in order to compare outcomes between cemented and uncemented total hip arthoplasties (THA). A quantitative orthopaedic outcome assessment scoring system was devised in order to relate functional outcome to a numerical score, to allow comparison between treatments and amongst centres. The system combined a radiographic score and a clinical score. Lower scores reflect better outcomes than higher scores. Consecutive cases of THA were included from two specialist practices between July 2002 and December 2005. The study included 46 THA patients (22 uncemented THA followed for 8.3 +/- 4.7M and 24 cemented THA for 26.0 +/- 15.7M) with a mean age of 4.4 +/- 3.3 years at surgery. Multi-variable linear and logistical regression analyses were performed with adjustments for age at surgery, surgeon, follow-up time, uni- versus bilateral disease, gender and body weight. The differences between treatment groups in terms of functional scores or total scores were not significant (p > 0.05). Radiographic scores were different between treatment groups. However, these scores were usually assessed within two months of surgery and proved unreliable predictors of functional outcome (p > 0.05). The findings reflect relatively short-term follow-up, especially for the uncemented group, and do not include clinician-derived measures, such as goniometry and thigh circumference. Longer-term follow-up for the radiographic assessments is essential. A prospective study including the clinician-derived outcomes needs to be performed in order to validate the outcome instrument in its modified form.

  20. Estimation of the Arterial Fraction of Total Hepatic Flow from Radionuclide Angiogram Using 99mTc-DISIDA

    International Nuclear Information System (INIS)

    Lee, Hae Gin; Lim, Gye Yeon; Yang, Il Kwon; Kim, Hack Hee; Lim, Jung Ik; Bahk, Yong Whee; Han, Sok Won; Han, Nam Ik; Lee, Young Sok

    1991-01-01

    Arterial fraction of total hepatic blood flow was estimated by a new method, slope method, on radionuclide angiogram using 99m Tc-DISIDA and was compared with that from 99m Tc-Phytate radionuclide angiogram. This study included 11 of normal subjects, 37 of intermediate group with various liver diseases, and 25 patients with liver cirrhosis. We analyzed the data with slope method from radionuclide angiograms and the results were compared with hepatic arterial fractions from uptake method, introduced by Lee et al. at 1986. The hepatic arterial fractions from radionuclide angiograms using 99m Tc-DISIDA and 99m Tc- Phytate were 0.32 ± 0.09 and 0.31 ± 0.11 respectively in normal subjects, and 0.75 ± 0.18 and 0.77 ± 0.21 respectively in patients with liver cirrhosis. The hepatic arterial fractions by the slope method was well correlated with those of the uptake method on 99m Tc-DISIDA scan. There was high correlation between the hepatic arterial fractions from 99m Tc-DISIDA and 99m Tc-Phytate scans. Hepatic arterial fraction estimated by the slope method is a useful index for the diagnosis of liver cirrhosis and the evaluation of status of portal hypertension.

  1. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    Science.gov (United States)

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  2. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  3. A comparative study of partial vs total splenectomy in thalassemia major patients

    Directory of Open Access Journals (Sweden)

    Bahador Ali

    2007-01-01

    Full Text Available Background : In this study, we show the advantages of partial splenectomy (PS over total splenectomy (TS regarding the chances of overwhelming postsplenectomy sepsis (OPSI. Materials and Methods: From February 1991 to December 1999, 143 cases of β-thalassemia underwent PS. 1/3, 1/4 of the splenic tissue was preserved. One hundred and ten cases were followed for an average of 5 years. None of the patients received vaccination or prophylactic antibiotics. Pre- and postoperative hematological profiles, IgM levels, recurrence of hypersplenism and septic episodes were compared among the data of 60 cases TS; all these cases have been operated in the same hospital. Results: Hematological profile significantly increased and transfusion requirement approximately reduced to three-fold. After 3 years, 22.7% in PS and 13.3% in TS groups required the same amount of preoperative transfusion. After 5 years, these percentages were 27.3 and 18.3%, respectively. Two patients in PS and six in TS group developed signs of sepsis. Conclusion : Vaccination or prophylactic antibiotics are not necessary after PS. The risk of sepsis in PS without antibiotics is less than that in TS with antibiotics, and resplenectomy after PS is not associated with serious complications.

  4. Marrow transplantation for leukemia following fractionated total body irradiation. A comparative trial of methotrexate and cyclosporine

    International Nuclear Information System (INIS)

    Irle, C.; Deeg, H.J.; Buckner, C.D.; Swedish Hospital Medical Center, Seattle, WA; Veterans Administration Hospital, Seattle, WA; Washington Univ., Seattle

    1985-01-01

    Fifty-six patients, 30-47 yr of age, with leukemia in relapse received allogeneic marrow transplants from HLA-identical siblings. All patients were treated with cyclophosphamide (120 mg/kg) and 7 daily fractions of 2.25 Gy of total body irradiation (TBI) for seven consecutive days. Nine patients (16%) are currently alive, free of disease, 324-845 days from transplantation. Actuarial relapse and survival rates at 2 yr were 56% and 9.5% respectively. These data were not remarkably different from those in previous studies using 10 Gy of TBI administered as a single dose. Thirty patients were randomized to receive methotrexate (MTX) and 26 to receive cyclosporine (CSP) as postgrafting prophylaxis for acute graft-versus-host disease (GVHD). Probability of developing significant acute GVHD by day 100 post-transplant was 71% for patients in the MTX group and 45% for patients in the CSP group (p<0.05). Probability of relapse was 37% for patients in the MTX group and 70% for patients in the CSP group (p<0.05). Transplant-related deaths were more frequent in the MTX group and leukemic deaths more frequent in the CSP group although this may have been related to an uneven distribution of high-risk patients. Long term disease-free survival was comparable. (author)

  5. Anterior Versus Posterolateral Approach for Total Laparoscopic Splenectomy: A Comparative Study

    Science.gov (United States)

    Ji, Bai; Wang, Yingchao; Zhang, Ping; Wang, Guangyi; Liu, Yahui

    2013-01-01

    Objective: Although the anterior approach is normally used for elective laparoscopic splenectomy (LS), the posterolateral approach may be superior. We have retrospectively compared the effectiveness and safety of these approaches in patients with non-severe splenomegaly scheduled for elective total LS. Methods: Patients with surgical spleen disorders scheduled for elective LS between March 2005 and June 2011 underwent laparoscopic splenic mobilization via the posterolateral or anterior approach. Main outcome measures included operation time, intraoperative blood loss, frequency of postoperative pancreatic leakage, and length of hospital stay. Results: During the study period, 203 patients underwent LS, 58 (28.6%) via the posterolateral and 145 (71.4%) via the anterior approach. Three patients (1.5%) required conversion to laparotomy due to extensive perisplenic adhesions. The posterolateral approach was associated with significantly shorter operation time (65.0 ± 12.3 min vs. 95.0 ± 21.3 min, P 0.05) Conclusions: The posterolateral approach is more effective and safer than the anterior approach in patients without severe splenomegaly (< 30 cm). PMID:23372427

  6. Flow cytometry total cell counts : A field study assessing microbiological water quality and growth in unchlorinated drinking water distribution systems

    NARCIS (Netherlands)

    Liu, G.; Van der Mark, E.J.; Verberk, J.Q.; Van Dijk, J.C.

    2013-01-01

    e objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs) as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A

  7. Total versus subtotal Laparoscopic Hysterectomy: A comparative study in Arash Hospital

    Directory of Open Access Journals (Sweden)

    Samiei H

    2009-09-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Over the past 50 years, subtotal or supracervical hysterectomy has come to be viewed as a suboptimal procedure reserved for those rare instances in which when concern over blood loss or anatomic distortion dictates limiting the extent of dissection, the aim of this study was to compare total and subtotal laparoscopic hysterectomy. "n"nMethods: The patients who were candidates for hysterectomy with benign disease, with no contraindication for laparoscopic surgery entered the study in Arash Hospital, from March 2007 to April 2009. By simple randomization 45 patients (25 for TLH and 20 for SLH were selected. Demographic Details and intra and post operative complications, were recorded by the staff and were compared between two groups."n"nResults: The average time for TLH operations look significantly longer than SLH operation (148.6±29.7 minutes; 128.5±25.64 minutes, p=0.03. Although, the hemoglobin (gr/dl drop in TLH was significantly higher than SLH (1.54 Versus 0.9, p<0.05 Blood transfusion were common in SLH (1 case Versus 3 Cases. The total length of hospital stay, was significantly shorter after SLH than TLH (3.6±1.47 day and 2.85±0.59, p=0.04. The drug requirements to

  8. Big Data and Total Hip Arthroplasty: How Do Large Databases Compare?

    Science.gov (United States)

    Bedard, Nicholas A; Pugely, Andrew J; McHugh, Michael A; Lux, Nathan R; Bozic, Kevin J; Callaghan, John J

    2018-01-01

    Use of large databases for orthopedic research has become extremely popular in recent years. Each database varies in the methods used to capture data and the population it represents. The purpose of this study was to evaluate how these databases differed in reported demographics, comorbidities, and postoperative complications for primary total hip arthroplasty (THA) patients. Primary THA patients were identified within National Surgical Quality Improvement Programs (NSQIP), Nationwide Inpatient Sample (NIS), Medicare Standard Analytic Files (MED), and Humana administrative claims database (HAC). NSQIP definitions for comorbidities and complications were matched to corresponding International Classification of Diseases, 9th Revision/Current Procedural Terminology codes to query the other databases. Demographics, comorbidities, and postoperative complications were compared. The number of patients from each database was 22,644 in HAC, 371,715 in MED, 188,779 in NIS, and 27,818 in NSQIP. Age and gender distribution were clinically similar. Overall, there was variation in prevalence of comorbidities and rates of postoperative complications between databases. As an example, NSQIP had more than twice the obesity than NIS. HAC and MED had more than 2 times the diabetics than NSQIP. Rates of deep infection and stroke 30 days after THA had more than 2-fold difference between all databases. Among databases commonly used in orthopedic research, there is considerable variation in complication rates following THA depending upon the database used for analysis. It is important to consider these differences when critically evaluating database research. Additionally, with the advent of bundled payments, these differences must be considered in risk adjustment models. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  10. Determination of total flow rate and flow rate of every operating branch in commissioning of heavy water loop for ARR-2

    International Nuclear Information System (INIS)

    Han Yan

    1997-01-01

    The heavy water loop (i,e, RCS) for ARR-2 in Algeria is a complex loop. Flow regulating means are not provided by the design in order to operate the reactor safely and simplify operating processes. How to determine precisely the orifice diameters of resistance parts for the loop is a key point for decreasing deviation between practical and design flow rates. Commissioning tests shall ensure that under every one of combined operating modes for the pumps, total coolant flow rate is about the same (the number of pumps operating in parallel is the same) and is consistent with design requirement, as well as the distribution of coolant flow rate to every branch is uniform. The flow Determination is divided into two steps. First and foremost, corresponding resistance part at each pump outlet is determined in commissioning test of shorted heavy water loop with light water, so that the problem about uniform distribution of the flow rate to each branch is solved, Secondly, resistance part at the reactor inlet is determined in commissioning test of heavy water loop connected with the vessel, so that the problem about that total heavy water flow rate is within optimal range is solved. According to practical requirements of the project, a computer program of hydraulic calculation and analysis for heavy water loop has been developed, and hydraulic characteristics test for a part of loop has been conducted in order to correct calculation error. By means of program calculation combining with tests in site, orifice diameters of 9 resistance parts has been determined rapidly and precisely and requirements of design and operation has been met adequately

  11. Effects of radiation and α-tocopherol on saliva flow rate, amylase activity, total protein and electrolyte levels in oral cavity cancer

    Directory of Open Access Journals (Sweden)

    Chitra S

    2008-01-01

    Full Text Available Objective: The objective of the present study was to evaluate early and late effects of radiation and a-tocopherol on the secretion rate of saliva and on selected saliva salivary parameters in oral cavity cancer patients. Patients & Methods: Eighty-nine histologically confirmed oral cavity cancer patients (OCC were enrolled in the study. Resting whole saliva was collected before, during and at the end of the radiation therapy (RT and simultaneous supplementation with α - tocopherol to the radiation treated patients (RT + AT. Results: Salivary flow rate, pH, amylase activity, total protein, sodium and potassium were analyzed. Increased pH, potassium and decreased flow rate, amylase activity, protein content and sodium were observed in 6 weeks of radiation treated patients when compared to OCC patients. A significant improvement of those parameters was observed on α - tocopherol supplementation in RT + AT patients. Conclusion: Supplementation with α - tocopherol improves the salivary flow rate thereby, maintains salivary parameters.

  12. [Effect of citric acid stimulation on salivary alpha-amylase, total protein, salivary flow rate and pH value in Pi deficiency children].

    Science.gov (United States)

    Yang, Ze-min; Chen, Long-hui; Lin, Jing; Zhang, Min; Yang, Xiao-rong; Chen, Wei-wen

    2015-02-01

    To compare the effect of citric acid stimulation on salivary alpha-amylase (sAA), total protein (TP), salivary flow rate, and pH value between Pi deficiency (PD) children and healthy children, thereby providing evidence for Pi controlling saliva theory. Twenty PD children were recruited, and 29 healthy children were also recruited at the same time. Saliva samples from all subjects were collected before and after citric acid stimulation. The sAA activity and amount, TP contents, salivary flow rate, and pH value were determined and compared. (1) Citric acid stimulation was able to significantly increase salivary flow rate, pH value, sAA activities, sAA specific activity and sAA amount (including glycosylated and non-glycosylated sAA amount) in healthy children (Psalivary flow rate, pH value, and glycosylated sAA levels in PD children (Psalivary indices between the two groups (P>0.05), salivary indices except salivary flow rate and glycosylated sAA levels decreased more in PD children. There was statistical difference in sAA activity ratio, sAA specific activity ratio, and the ratio of glycosylated sAA levels between PD children and healthy children (P<0.05). PD children had decreased response to citric acid stimulation.

  13. A randomized, controlled trial comparing local infiltration analgesia with epidural infusion for total knee arthroplasty

    DEFF Research Database (Denmark)

    Andersen, Karen Vestergaard; Bak, Marie; Christensen, Birgitte Viebæk

    2010-01-01

    There have been few studies describing wound infiltration with additional intraarticular administration of multimodal analgesia for total knee arthroplasty (TKA). In this study, we assessed the efficacy of wound infiltration combined with intraarticular regional analgesia with epidural infusion...

  14. Comparative Analysis of Total Phenolic Content in Sea Buckthorn Wine and Other Selected Fruit Wines

    OpenAIRE

    Bharti Negi; Gargi Dey

    2009-01-01

    This is the first report from India on a beverage resulting from alcoholic fermentation of the juice of sea buckthorn (Hippophae rhamnoides L) using lab isolated yeast strain. The health promoting potential of the product was evaluated based on its total phenolic content. The most important finding was that under the present fermentation condition, the total phenolic content of the wine product was 689 mg GAE/L. Investigation of influence of bottle ageing on the sea buckthorn wine showed a sl...

  15. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    Science.gov (United States)

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Comparative evolution of coagulation disorders in baboons and Pigs after total body irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Lefleche, P.; Veyret, J.; Grasseau, A.; Agay, D.; Mestries, J.C.

    1994-01-01

    Acute total body irradiation in pigs, with a lethal dose of either gamma or mixed gamma-neutron radiation, induced similar plasmatic coagulation disorders as those observed in baboons. These data validated pathophysiological hypothesis which were developed during previous studies, but do not support the idea of a possible species specific radiosensitivity. (author)

  17. Application of two-phase flow for cooling of hybrid microchannel PV cells: A comparative study

    International Nuclear Information System (INIS)

    Valeh-e-Sheyda, Peyvand; Rahimi, Masoud; Karimi, Ebrahim; Asadi, Masomeh

    2013-01-01

    Highlights: ► Showing cooling potential of gas–liquid two-phase flow in microchannels for PV cell. ► Introducing the concept of using slug flow in microchannels for cooling of PV cells. ► In single-phase flow, increasing the liquid flow rate enhances the PV power. ► Showing that in two-phase flow the output power related the fluid flow regime. ► By coupling PV and microchannel an increase up to 38% in output power was observed. - Abstract: This paper reports the experimental data from performance of two-phase flows in a small hybrid microchannel solar cell. Using air and water as two-phase fluid, the experiments were conducted at indoor condition in an array of rectangular microchannels with a hydraulic diameter of 0.667 mm. The gas superficial velocity ranges were between 0 and 3.27 m s −1 while liquid flow rate was 0.04 m s −1 . The performance analysis of the PV cell at slug and transitional slug/annular flow regimes are the focus of this study. The influence of two-phase working fluid on PV cell cooling was compared with single-phase. In addition, the great potential of slug flow for heat removal enhancement in PV/T panel was investigated. The obtained data showed the proposed hybrid system could substantially increases the output power of PV solar cells

  18. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Chromium Fractions Changes Compared With Total-Cr As Determined by Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Abdel-Sabour, M.F.; Abdou, F.M.; Elwan, I.M.; Al-Salama, Y.J.

    2003-01-01

    Fifteen soil samples were chosen from different locations (five different locations at north greater Cairo, Egypt to represent different soils (alluvial and sandy) as well as different source of contaminated wastewater (sewage and industrial effluent). Using sequential extraction technique (extracting the soil with different solutions, which is designed to separate metal fractions), Cr was separated into six operationally defined fractions water soluble, exchangeable, carbonate bound, Fe-Mn oxides bound, organic bound and residual fractions. Result of soil total-Cr indicated the serious accumulation of Cr in soils subjected to prolonged irrigation with contaminated wastewater. As it could seen, total-Cr in the tested contaminated soils exceeds the permissible levels (75-100)ppm Cr by several order of magnitude particularly at the surface and subsurface layers. The highest accumulation of total Cr down to depth 60 cm was observed in case of soil E. Data showed that values of total Cr determined by NAA method were always higher than the relevant values determined either by AAS or those calculated after the sequential extraction method. T-test analysis showed the significant difference between NAA and either AAS or sequential extraction methods. Although T-test analysis showed that were significant differences between total content in soils as determined by destructive (AAS or SUM) and non-destructive (NAA) analytical techniques however, strong liner relation between NAA and other tested methods was obtained. Chromium distribution between different extractants shows that the greatest amounts are found in the residual and Occluded in Fe and Mn-Oxides fractions followed by carbonate or organic fractions. In most cases the proportion of all tested Cr-forms has increased in contaminated soil layers with higher enrichment in organically bound Cr, occluded in Fe and Mn oxides, carbonate exchangeable and soluble fractions. Results indicate that soil properties have a

  20. A comparative study of species migration and diffusion mechanisms in all-vanadium redox flow batteries

    International Nuclear Information System (INIS)

    Oh, Kyeongmin; Won, Seongyeon; Ju, Hyunchul

    2015-01-01

    Highlights: • Migration effects on crossover phenomena is examined. • Crossover and migration model is newly implemented. • Totally opposite crossover trend is observed with migration during charging. • During discharging, the crossover is enhanced due to migration. - ABSTRACT: According to the Nernst–Planck equation, the transport of charged species in porous electrodes is mainly driven by diffusion and migration. Although a number of all-vanadium redox flow battery (VRFB) models have been developed by several VRFB modeling groups, a comparative study of these two ion transport mechanisms has not been clearly reported in the literature. In this study, we develop a three-dimensional (3-D), transient VRFB model that rigorously accounts for both diffusion and migration mechanisms of charged species, including V 2+ , V 3+ , VO 2+ ,VO 2 + and H + . The VRFB model relies upon five principles of conservation: mass, momentum, species, electric charge, and thermal energy. Due to the general form of the conservation equations, both species migration effects on species transport and species diffusion effects on charge transport are considered in the source terms of the model equations. The model calculates species migration and diffusion fluxes through the membrane and compares their relative magnitudes under various charging and discharging stages. This paper clearly elucidates the role of species migration on vanadium crossover and the subsequent capacity losses, demonstrating that the present VRFB model is a valuable tool for optimizing the component design and operation of VRFBs.

  1. An alternative low-loss stack topology for vanadium redox flow battery: Comparative assessment

    Science.gov (United States)

    Moro, Federico; Trovò, Andrea; Bortolin, Stefano; Del, Davide, , Col; Guarnieri, Massimo

    2017-02-01

    Two vanadium redox flow battery topologies have been compared. In the conventional series stack, bipolar plates connect cells electrically in series and hydraulically in parallel. The alternative topology consists of cells connected in parallel inside stacks by means of monopolar plates in order to reduce shunt currents along channels and manifolds. Channelled and flat current collectors interposed between cells were considered in both topologies. In order to compute the stack losses, an equivalent circuit model of a VRFB cell was built from a 2D FEM multiphysics numerical model based on Comsol®, accounting for coupled electrical, electrochemical, and charge and mass transport phenomena. Shunt currents were computed inside the cells with 3D FEM models and in the piping and manifolds by means of equivalent circuits solved with Matlab®. Hydraulic losses were computed with analytical models in piping and manifolds and with 3D numerical analyses based on ANSYS Fluent® in the cell porous electrodes. Total losses in the alternative topology resulted one order of magnitude lower than in an equivalent conventional battery. The alternative topology with channelled current collectors exhibits the lowest shunt currents and hydraulic losses, with round-trip efficiency higher by about 10%, as compared to the conventional topology.

  2. Comparative evaluation of total RNA extraction methods in Theobroma cacao using shoot apical meristems.

    Science.gov (United States)

    Silva, D V; Branco, S M J; Holanda, I S A; Royaert, S; Motamayor, J C; Marelli, J P; Corrêa, R X

    2016-03-04

    Theobroma cacao is a species of great economic importance with its beans used for chocolate production. The tree has been a target of various molecular studies. It contains many polyphenols, which complicate the extraction of nucleic acids with the extraction protocols requiring a large amount of plant material. These issues, therefore, necessitate the optimization of the protocols. The aim of the present study was to evaluate different methods for extraction of total RNA from shoot apical meristems of T. cacao 'CCN 51' and to assess the influence of storage conditions for the meristems on the extraction. The study also aimed to identify the most efficient protocol for RNA extraction using a small amount of plant material. Four different protocols were evaluated for RNA extraction using one shoot apical meristem per sample. Among these protocols, one that was more efficient was then tested to extract RNA using four different numbers of shoot apical meristems, subjected to three different storage conditions. The best protocol was tested for cDNA amplification using reverse transcription-polymerase chain reaction; the cDNA quality was determined to be satisfactory for molecular analyses. The study revealed that with the best RNA extraction protocol, one shoot apical meristem was sufficient for extraction of high-quality total RNA. The results obtained might enable advances in genetic analyses and molecular studies using reduced amount of plant material.

  3. Comparative study of the total phenol content and antioxidant activity of some medicinal herbal extracts

    Directory of Open Access Journals (Sweden)

    H. Hajimehdipoor

    2014-08-01

    Full Text Available Herbal medicines can be used as the potential sources of anti-oxidative compounds to help the treatment of diseases associated to oxidative stress. In this paper, the Ferric Reducing Antioxidant Power (FRAP activity of four Lamiaceae herbal extracts, which traditionally applied in oxidative stress related diseases, has been evaluated and total phenolics contents of these extracts determined by using Folin-Ciocalteu reagent. The aqueous methanol extracts were prepared by percolation method and investigated for antioxidant properties and total phenolics content evaluation. All the extracts showed antioxidant effect from 123.6±4.6 mmol of FeSO4.7H2Oequivalent/100 g dried extract in Scutellaria tornefortii to 551.5±16.0 mmol of FeSO4.7H2Oequivalent/100 g dried extract in Satureja sahendica. Interestingly, although Satureja sahendica exhibited the most antioxidant activity, the highest content of polyphenolics belonged to Stachys byzantina. Taking together, antioxidant activity of the mentioned medicinal plants is not necessarily associated with polyphenolic compounds and might be partially due to the presence of other polar constituents like terpenoid-glycosides in aqueous extracts that traditionally used as decoction.

  4. A Primal-Dual Approach for a Total Variation Wasserstein Flow

    KAUST Repository

    Benning, Martin; Calatroni, Luca; Dü ring, Bertram; Schö nlieb, Carola-Bibiane

    2013-01-01

    We consider a nonlinear fourth-order diffusion equation that arises in denoising of image densities. We propose an implicit time-stepping scheme that employs a primal-dual method for computing the subgradient of the total variation seminorm. The constraint on the dual variable is relaxed by adding a penalty term, depending on a parameter that determines the weight of the penalisation. The paper is furnished with some numerical examples showing the denoising properties of the model considered. © 2013 Springer-Verlag.

  5. Flow-through Fourier transform infrared sensor for total hydrocarbons determination in water.

    Science.gov (United States)

    Pérez-Palacios, David; Armenta, Sergio; Lendl, Bernhard

    2009-09-01

    A new flow-through Fourier transform infrared (FT-IR) sensor for oil in water analysis based on solid-phase spectroscopy on octadecyl (C18) silica particles has been developed. The C18 non-polar sorbent is placed inside the sensor and is able to retain hydrocarbons from water samples. The system does not require the use of chlorinated solvents, reducing the environmental impact, and the minimal sample handling stages serve to ensure sample integrity whilst reducing exposure of the analyst to any toxic hydrocarbons present within the samples. Fourier transform infrared (FT-IR) spectra were recorded by co-adding 32 scans at a resolution of 4 cm(-1) and the band located at 1462 cm(-1) due to the CH(2) bending was integrated from 1475 to 1450 cm(-1) using a baseline correction established between 1485 and 1440 cm(-1) using the areas as analytical signal. The technique, which provides a limit of detection (LOD) of 22 mg L(-1) and a precision expressed as relative standard deviation (RSD) lower than 5%, is considerably rapid and allows for a high level of automation.

  6. An Enhanced Discrete Artificial Bee Colony Algorithm to Minimize the Total Flow Time in Permutation Flow Shop Scheduling with Limited Buffers

    Directory of Open Access Journals (Sweden)

    Guanlong Deng

    2016-01-01

    Full Text Available This paper presents an enhanced discrete artificial bee colony algorithm for minimizing the total flow time in the flow shop scheduling problem with buffer capacity. First, the solution in the algorithm is represented as discrete job permutation to directly convert to active schedule. Then, we present a simple and effective scheme called best insertion for the employed bee and onlooker bee and introduce a combined local search exploring both insertion and swap neighborhood. To validate the performance of the presented algorithm, a computational campaign is carried out on the Taillard benchmark instances, and computations and comparisons show that the proposed algorithm is not only capable of solving the benchmark set better than the existing discrete differential evolution algorithm and iterated greedy algorithm, but also capable of performing better than two recently proposed discrete artificial bee colony algorithms.

  7. Comparing two models for post-wildfire debris flow susceptibility mapping

    Science.gov (United States)

    Cramer, J.; Bursik, M. I.; Legorreta Paulin, G.

    2017-12-01

    Traditionally, probabilistic post-fire debris flow susceptibility mapping has been performed based on the typical method of failure for debris flows/landslides, where slip occurs along a basal shear zone as a result of rainfall infiltration. Recent studies have argued that post-fire debris flows are fundamentally different in their method of initiation, which is not infiltration-driven, but surface runoff-driven. We test these competing models by comparing the accuracy of the susceptibility maps produced by each initiation method. Debris flow susceptibility maps are generated according to each initiation method for a mountainous region of Southern California that recently experienced wildfire and subsequent debris flows. A multiple logistic regression (MLR), which uses the occurrence of past debris flows and the values of environmental parameters, was used to determine the probability of future debris flow occurrence. The independent variables used in the MLR are dependent on the initiation method; for example, depth to slip plane, and shear strength of soil are relevant to the infiltration initiation, but not surface runoff. A post-fire debris flow inventory serves as the standard to compare the two susceptibility maps, and was generated by LiDAR analysis and field based ground-truthing. The amount of overlap between the true locations where debris flow erosion can be documented, and where the MLR predicts high probability of debris flow initiation was statistically quantified. The Figure of Merit in Space (FMS) was used to compare the two models, and the results of the FMS comparison suggest that surface runoff-driven initiation better explains debris flow occurrence. Wildfire can breed conditions that induce debris flows in areas that normally would not be prone to them. Because of this, nearby communities at risk may not be equipped to protect themselves against debris flows. In California, there are just a few months between wildland fire season and the wet

  8. A comparative assessment of antioxidant properties, total phenolic content of einkorn, wheat, barley and their malts.

    Science.gov (United States)

    Fogarasi, Attila-Levente; Kun, Szilárd; Tankó, Gabriella; Stefanovits-Bányai, Eva; Hegyesné-Vecseri, Beáta

    2015-01-15

    Two einkorn wheat, one barley, three optional winter cultivation wheat and five winter cultivation wheat samples harvested in Hungary in 2011, and their malts were evaluated for their DPPH radical and ABTS radical cation scavenging activity, ferric reduction capacity (FRAP) and total phenolic content (TPC). All einkorn and barley samples exhibited significant antioxidant activities determined by DPPH and ABTS radical scavenging activities. The einkorn samples show higher polyphenol content than the other wheat samples. In all cases the barley sample had the highest antioxidant potential and polyphenol content. The einkorn malts had high DPPH and ABTS radical cation scavenging activities, but the phenolic content was lower against wheat samples. There was significant difference between the antioxidant potential of optional and winter cultivation wheat samples except on ABTS scavenging activities. Einkorn wheat is potentially a new raw material to produce organic beer that might have beneficial effects with its increased antioxidant potential. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Studying flow close to an interface by total internal reflection fluorescence cross-correlation spectroscopy: Quantitative data analysis

    Science.gov (United States)

    Schmitz, R.; Yordanov, S.; Butt, H. J.; Koynov, K.; Dünweg, B.

    2011-12-01

    Total internal reflection fluorescence cross-correlation spectroscopy (TIR-FCCS) has recently [S. Yordanov , Optics ExpressOPEXFF1094-408710.1364/OE.17.021149 17, 21149 (2009)] been established as an experimental method to probe hydrodynamic flows near surfaces, on length scales of tens of nanometers. Its main advantage is that fluorescence occurs only for tracer particles close to the surface, thus resulting in high sensitivity. However, the measured correlation functions provide only rather indirect information about the flow parameters of interest, such as the shear rate and the slip length. In the present paper, we show how to combine detailed and fairly realistic theoretical modeling of the phenomena by Brownian dynamics simulations with accurate measurements of the correlation functions, in order to establish a quantitative method to retrieve the flow properties from the experiments. First, Brownian dynamics is used to sample highly accurate correlation functions for a fixed set of model parameters. Second, these parameters are varied systematically by means of an importance-sampling Monte Carlo procedure in order to fit the experiments. This provides the optimum parameter values together with their statistical error bars. The approach is well suited for massively parallel computers, which allows us to do the data analysis within moderate computing times. The method is applied to flow near a hydrophilic surface, where the slip length is observed to be smaller than 10nm, and, within the limitations of the experiments and the model, indistinguishable from zero.

  10. Skin blood flow from gas transport: helium xenon and laser Doppler compared

    International Nuclear Information System (INIS)

    Neufeld, G.R.; Galante, S.R.; Whang, J.M.; DeVries, D.; Baumgardner, J.E.; Graves, D.J.; Quinn, J.A.

    1988-01-01

    A study was designed to compare three independent measures of cutaneous blood flow in normal healthy volunteers: xenon-133 washout, helium flux, and laser velocimetry. All measurements were confined to the volar aspect of the forearm. In a large group of subjects we found that helium flux through intact skin changes nonlinearly with the controlled local skin temperature whereas helium flux through stripped skin, which is directly proportional to skin blood flow, changes linearly with cutaneous temperature over the range 33 degrees to 42 degrees. In a second group of six volunteers we compared helium flux through stripped skin to xenon-133 washout (intact skin) at a skin temperature of 33 degrees, and we found an essentially linear relationship between helium flux and xenon measured blood flow. In a third group of subjects we compared helium flux blood flow (stripped skin) to laser doppler velocimetric (LDV) measurements (intact skin) at adjacent skin sites and found a nonlinear increase in the LDV skin blood flow compared to that determined by helium over the same temperature range. A possible explanation for the nonlinear increases of helium flux through intact skin and of LDV output with increasing local skin temperature is that they reflect more than a change in blood flow. They may also reflect physical changes in the stratum corneum, which alters its diffusional resistance to gas flux and its optical characteristics

  11. Skin blood flow from gas transport: helium xenon and laser Doppler compared

    Energy Technology Data Exchange (ETDEWEB)

    Neufeld, G.R.; Galante, S.R.; Whang, J.M.; DeVries, D.; Baumgardner, J.E.; Graves, D.J.; Quinn, J.A.

    1988-03-01

    A study was designed to compare three independent measures of cutaneous blood flow in normal healthy volunteers: xenon-133 washout, helium flux, and laser velocimetry. All measurements were confined to the volar aspect of the forearm. In a large group of subjects we found that helium flux through intact skin changes nonlinearly with the controlled local skin temperature whereas helium flux through stripped skin, which is directly proportional to skin blood flow, changes linearly with cutaneous temperature over the range 33 degrees to 42 degrees. In a second group of six volunteers we compared helium flux through stripped skin to xenon-133 washout (intact skin) at a skin temperature of 33 degrees, and we found an essentially linear relationship between helium flux and xenon measured blood flow. In a third group of subjects we compared helium flux blood flow (stripped skin) to laser doppler velocimetric (LDV) measurements (intact skin) at adjacent skin sites and found a nonlinear increase in the LDV skin blood flow compared to that determined by helium over the same temperature range. A possible explanation for the nonlinear increases of helium flux through intact skin and of LDV output with increasing local skin temperature is that they reflect more than a change in blood flow. They may also reflect physical changes in the stratum corneum, which alters its diffusional resistance to gas flux and its optical characteristics.

  12. Investigation of the Unsteady Total Pressure Profile Corresponding to Counter-Rotating Vortices in an Internal Flow Application

    Science.gov (United States)

    Gordon, Kathryn; Morris, Scott; Jemcov, Aleksandar; Cameron, Joshua

    2013-11-01

    The interaction of components in a compressible, internal flow often results in unsteady interactions between the wakes and moving blades. A prime example in which this flow feature is of interest is the interaction between the downstream rotor blades in a transonic axial compressor with the wake vortices shed from the upstream inlet guide vane (IGV). Previous work shows that a double row of counter-rotating vortices convects downstream into the rotor passage as a result of the rotor blade bow shock impinging on the IGV. The rotor-relative time-mean total pressure distribution has a region of high total pressure corresponding to the pathline of the vortices. The present work focuses on the relationship between the magnitude of the time-mean rotor-relative total pressure profile and the axial spacing between the IGV and the rotor. A survey of different axial gap sizes is performed in a two-dimensional computational study to obtain the sensitivity of the pressure profile amplitude to IGV-rotor axial spacing.

  13. A comparative study of total body irradiation as a method of inducing granulocyte depletion in mice

    International Nuclear Information System (INIS)

    Bogman, M.J.J.T.; Cornelissen, I.M.H.A.; Berden, J.H.M.; Jong, J. de; Koene, R.A.P.

    1984-01-01

    Since conventional methods of inducing depletion of polymorphonuclear granulocytes (PMNs) in mice, such as treatment with cytostatic drugs and anti-PMN sera, proved to be insufficient to induce a stable PMN depletion for several days, and were accompanied by considerable toxic side effects, we induced neutrophil depletion in mice by total body irradiation (TBI) in a single dose of 6.0 Gy (600 rads.) at a dose rate of 0.20 Gy/min. This treatment reduced the number of PMNs in the peripheral circulation to values below 150/μl from day 3-10 after irradiation. The number of lymphocytes fell simultaneously. Platelet counts remained above 60% of normal values during the first 7 days after irradiation. Complement levels were not significantly affected by TBI. The results show that TBI of 6.0 Gy induces pronounced and stable PMN depletion in mice for at least 7 days. Furthermore, under an aseptic regimen the mice can be kept in good condition and losses are less than 5%. (Auth.)

  14. Relationship of myocardial hibernation, scar, and angiographic collateral flow in ischemic cardiomyopathy with coronary chronic total occlusion.

    Science.gov (United States)

    Wang, Li; Lu, Min-Jie; Feng, Lei; Wang, Juan; Fang, Wei; He, Zuo-Xiang; Dou, Ke-Fei; Zhao, Shi-Hua; Yang, Min-Fu

    2018-03-07

    The relationship between myocardial viability and angiographic collateral flow is not fully elucidated in ischemic cardiomyopathy (ICM) with coronary artery chronic total occlusion (CTO). We aimed to clarify the relationship between myocardial hibernation, myocardial scar, and angiographic collateral flow in these patients. Seventy-one consecutive ICM patients with 122 CTOs and 652 dysfunctional segments within CTO territories were retrospectively analyzed. Myocardial hibernation (perfusion-metabolism mismatch) and the extent of 18 F-fluorodeoxyglucose (FDG) abnormalities were assessed using 99m Tc-sestamibi and 18 F-FDG imaging. Myocardial scar was evaluated by late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) imaging. Collateral flow observed on coronary angiography was assessed using Rentrop classification. In these patients, neither the extent nor frequency of myocardial hibernation or scar was related to the status of collateral flow. Moreover, the matching rate in determining myocardial viability was poor between any 2 imaging indices. The extent of 18 F-FDG abnormalities was linearly related to the extent of LGE rather than myocardial hibernation. Of note, nearly one-third (30.4%) of segments with transmural scar still had hibernating tissue. Hibernation and non-transmural scar had higher sensitivity (63.0% and 66.7%) than collateral flow (37.0%) in predicting global functional improvement. Angiographic collateral cannot accurately predict myocardial viability, and has lower sensitivity in prediction of functional improvement in CTO territories in ICM patients. Hence, assessment of myocardial viability with non-invasive imaging modalities is of importance. Moreover, due to the lack of correlation between myocardial hibernation and scar, these two indices are complementary but not interchangeable.

  15. Report on research and development achievements in fiscal 1980 in Sunshine Project. Development of a total flow electric power plant(Two-phase rotation inflator); 1980 nendo total flow hatsuden plant no kaihatsu seika hokokusho. Niso kaiten bochoki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1981-03-01

    Out of the development of a total flow power plant in the Sunshine Project, this paper describes a two-phase rotatry inflator. It reports the achievements in fiscal 1980. It is intended to utilize effectively the energy of gas-liquid two-phase fluid (containing a great amount of hot water) often seen in geothermal resources in Japan. Therefore, development is considered on a two-phase rotary inflator as a total flow power generation technology to inflate the gas-liquid fluid as it is without performing separation thereof, and convert it to an external work to draw out output. The inflator is a volume type rotary engine, which has the highest efficiency theoretically, but has not been put into practical use worldwide. Based on the result obtained in the previous fiscal year, development is made on a most suitable seal to be applied to circumferential seal of an external rotor, apex seal, and intake port seal. A rotary inflation performance testing machine is fabricated to study inflation of the gas-liquid two-phase fluid. Setting the engine efficiency of 60% or higher as the target, detailed design, fabrication and assembly shall be completed on two-phase rotation inflators of volume type and self-rotation type of 300 kW class. (NEDO)

  16. Measurement of the ecological flow of the Acaponeta river, Nayarit, comparing different time intervals

    Directory of Open Access Journals (Sweden)

    Guadalupe de la Lanza Espino

    2012-07-01

    Full Text Available The diverse management of river water in Mexico has been unequal due to the different anthropological activities, and it is associated with inter-annual changes in the climate and runoff patterns, leading to a loss of the ecosystem integrity. However, nowadays there are different methods to assess the water volume that is necessary to conserve the environment, among which are hydrological methods, such as those applied here, that are based on information on water volumes recorded over decades, which are not always available in the country. For this reason, this study compares runoff records for different time ranges: minimum of 10 years, medium of 20 years, and more than 50 years, to quantify the environmental flow. These time intervals provided similar results, which mean that not only for the Acaponeta river, but possibly for others lotic systems as well, a 10-year interval may be used satisfactorily. In this river, the runoff water that must be kept for environmental purposes is: for 10 years 70.1%, for 20 years 78.1% and for >50 years 68.8%, with an average of 72.3% of the total water volume or of the average annual runoff.

  17. Determination Total Phosphour of Maize Plant Samples by Continuous Flow Analyzer in Comparison with Vanadium Molybdate Yellow Colorimetric Method

    OpenAIRE

    LIU Yun-xia; WEN Yun-jie; HUANG Jin-li; LI Gui-hua; CHAI Xiao; WANG Hong

    2015-01-01

    The vanadium molybdate yellow colorimetric method(VMYC method) is regarded as one of conventional methods for determining total phosphorus(P) in plants, but it is time consuming procedure. Continuous flow analyzer(CFA) is a fluid stream segmentation technique with air segments. It is used to measure P concentration based on the molybdate-antimony-ascorbic acid method of Murphy and Riley. Sixty nine of maize plant samples were selected and digested with H2SO4-H2O2. P concentrations in the dige...

  18. Analysis of cell flow and cell loss following X-irradiation using sequential investigation of the total number of cells in the various parts of the cell cycle

    International Nuclear Information System (INIS)

    Skog, S.; Tribukait, B.

    1985-01-01

    The cell flow and cell loss of an in vivo growing Ehrlich ascites tumour were calculated by sequential estimation of changes in total number of cells in the cell cycle compartments. Normal growth was compared with the grossly disturbed cell flow evident after a 5 Gy X-irradiation. The doubling time of normal, exponentially growing cells was 24 hr. The generation time was 21 hr and the potential doubling time was 21 hr. Thus, the growth fraction was 1.0 and the cell loss rate about 0.5%/hr. Following irradiation, a transiently increased relative outflow rate from all cell cycle compartments was found at about 3 and 40 hr, and from S phase at 24 hr after irradiation. Increase in cell loss as well as non-viable cells was observed at 24 hr after irradiation at the time of release of the irradiation-induced G 2 blockage. The experiments show the applicability and limitations of cell flow and cell loss calculations by sequential analysis of the total number of cells in the various parts of the cell cycle. (author)

  19. Comparative Analysis of River Flow Modelling by Using Supervised Learning Technique

    Science.gov (United States)

    Ismail, Shuhaida; Mohamad Pandiahi, Siraj; Shabri, Ani; Mustapha, Aida

    2018-04-01

    The goal of this research is to investigate the efficiency of three supervised learning algorithms for forecasting monthly river flow of the Indus River in Pakistan, spread over 550 square miles or 1800 square kilometres. The algorithms include the Least Square Support Vector Machine (LSSVM), Artificial Neural Network (ANN) and Wavelet Regression (WR). The forecasting models predict the monthly river flow obtained from the three models individually for river flow data and the accuracy of the all models were then compared against each other. The monthly river flow of the said river has been forecasted using these three models. The obtained results were compared and statistically analysed. Then, the results of this analytical comparison showed that LSSVM model is more precise in the monthly river flow forecasting. It was found that LSSVM has he higher r with the value of 0.934 compared to other models. This indicate that LSSVM is more accurate and efficient as compared to the ANN and WR model.

  20. Oil flow in deep waters: comparative study between light oils and heavy oils

    Energy Technology Data Exchange (ETDEWEB)

    Andreolli, Ivanilto [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2009-12-19

    Ultra deeper waters fields are being exploited due to technological development. Under this scenario, the flow design is accomplished through pipelines subjected to low temperature and high pressure. Moreover, these flow lines are usually long causing a fast fluid cooling, which may affect flow assurance in some cases. Problems during topsides production plant's restart might occur if the oil is viscous and even in steady state a significant different behavior can be noticed, if compared to a less viscous oil. A comparison between light and heavy oil through a case study with the objective to show some heavy oil flow particularities is the purpose of this paper. Permanent and transient analyses for a specific geometry are presented. The results showed that thermal and proper viscosity modeling are required for heavy oil flow, differently from that of light oil flow, due to the exponential viscosity dependence to temperature and because the predominant laminar regime. In addition, on heavier and heavier oil flow systems, it is essential to consider exportation system's restart. (author)

  1. Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels

    Science.gov (United States)

    Ma, Chao; Ji, Yongbin; Ge, Bing; Zang, Shusheng; Chen, Hua

    2018-04-01

    A comparative experimental study of heat transfer characteristics of steam and air flow in rectangular channels roughened with parallel ribs was conducted by using an infrared camera. Effects of Reynolds numbers and rib angles on the steam and air convective heat transfer have been obtained and compared with each other for the Reynolds number from about 4,000 to 15,000. For all the ribbed channels the rib pitch to height ratio (p/e) is 10, and the rib height to the channel hydraulic diameter ratio is 0.078, while the rib angles are varied from 90° to 45°. Based on experimental results, it can be found that, even though the heat transfer distributions of steam and air flow in the ribbed channels are similar to each other, the steam flow can obtain higher convective heat transfer enhancement capability, and the heat transfer enhancement of both the steam and air becomes greater with the rib angle deceasing from 90° to 45°. At Reynolds number of about 12,000, the area-averaged Nusselt numbers of the steam flow is about 13.9%, 14.2%, 19.9% and 23.9% higher than those of the air flow for the rib angles of 90°, 75°, 60° and 45° respectively. With the experimental results the correlations for Nusselt number in terms of Reynolds number and rib angle for the steam and air flow in the ribbed channels were developed respectively.

  2. A Comparative Analysis of the Flow Properties between Two Alumina-Based Dry Powders

    Directory of Open Access Journals (Sweden)

    Milene Minniti de Campos

    2013-01-01

    Full Text Available We measured and compared the flow properties of two alumina-based powders. The alumina powder (AP is irregularly shaped and has a smooth surface and moisture content of 0.16% (d.b., and the ceramic powder (CP, obtained after atomization in a spray dryer, is spherical and has a rough surface and moisture content of 1.07%. We measured the Hausner ratio (HR, the static angle of repose (AoR, the flow index (FI, the angle of internal friction, and the wall's friction angle. The properties measured using aerated techniques (AoR and HR demonstrated that AP presents true cohesiveness (and therefore a difficult flow, while CP presents some cohesiveness and its flow might be classified as half way between difficult and easy flow. Their FI values, which were obtained using a nonaerated technique, enable us to classify the alumina as cohesive and the ceramic powder as an easy-flow powder. The large mean diameter and morphological characteristics of CP reduce interparticle forces and improve flowability, in spite of the higher moisture content of their granules. The angles of internal friction and of wall friction were not significantly different when comparing the two powders.

  3. Detection of Total Phenol in Green and Black Teas by Flow Injection System and Unmodified Screen Printed Electrode

    Directory of Open Access Journals (Sweden)

    Ivanildo Luiz de Mattos

    2010-01-01

    Full Text Available A flow injection system using an unmodified gold screen-printed electrode was employed for total phenol determination in black and green teas. In order to avoid passivation of the electrode surface due to the redox reaction, preoxidation of the sample was realized by hexacyanoferrate(III followed by addition of an EDTA solution. The complex formed in the presence of EDTA minimizes or avoids polymerization of the oxidized phenols. The previously filtered tea sample and hexacyanoferrate(III reagent were introduced simultaneously into two-carrier streams producing two reproducible zones. At confluence point, the pre-oxidation of the phenolic compounds occurs while this zone flows through the coiled reactor and receives the EDTA solution before phenol detection. The consumption of ferricyanide was monitorized at 360 mV versus Ag/AgCl and reflected the total amount of phenolic compounds present in the sample. Results were reported as gallic acid equivalents (GAEs. The proposed system is robust, versatile, environmentally-friendly (since the reactive is used only in the presence of the sample, and allows the analysis of about 35–40 samples per hour with detection limit = 1 mg/L without the necessity for surface cleaning after each measurement. Precise results are in agreement with those obtained by the Folin-Ciocalteu method.

  4. Comparative Assessments of the Seasonality in "The Total Number of Overnight Stays" in Romania, Bulgaria and the European Union

    Directory of Open Access Journals (Sweden)

    Jugănaru Ion Dănuț

    2017-01-01

    For the quantitative research carried out in this study, we processed a database consisting of the monthly values of “the total number of overnight stays” indicator, recorded between January 2005 and December 2016, using the moving average method, the seasonality coefficient and EViews 5. The results led to the formulation of comparative assessments regarding the seasonality in the tourism activities from Romania and Bulgaria and their situation compared to the average of the seasonality recorded in the EU.

  5. Particle size reduction in debris flows: Laboratory experiments compared with field data from Inyo Creek, California

    Science.gov (United States)

    Arabnia, O.; Sklar, L. S.; Mclaughlin, M. K.

    2014-12-01

    . Laboratory data are compared with longitudinal evolution of grain size and angularity of particles deposited by debris flows along Inyo Creek, Sierra Nevada, California. Preliminary results suggest wear rates can be scaled across drum sizes and to field conditions using non-dimensional metrics of flow dynamics including Savage, Bagnold, and Froude numbers.

  6. Total Mini-Mental State Examination score and regional cerebral blood flow using Z score imaging and automated ROI analysis software in subjects with memory impairment

    International Nuclear Information System (INIS)

    Ikeda, Eiji; Shiozaki, Kazumasa; Takahashi, Nobukazu; Togo, Takashi; Odawara, Toshinari; Oka, Takashi; Inoue, Tomio; Hirayasu, Yoshio

    2008-01-01

    The Mini-Mental State Examination (MMSE) is considered a useful supplementary method to diagnose dementia and evaluate the severity of cognitive disturbance. However, the region of the cerebrum that correlates with the MMSE score is not clear. Recently, a new method was developed to analyze regional cerebral blood flow (rCBF) using a Z score imaging system (eZIS). This system shows changes of rCBF when compared with a normal database. In addition, a three-dimensional stereotaxic region of interest (ROI) template (3DSRT), fully automated ROI analysis software was developed. The objective of this study was to investigate the correlation between rCBF changes and total MMSE score using these new methods. The association between total MMSE score and rCBF changes was investigated in 24 patients (mean age±standard deviation (SD) 71.5±9.2 years; 6 men and 18 women) with memory impairment using eZIS and 3DSRT. Step-wise multiple regression analysis was used for multivariate analysis, with the total MMSE score as the dependent variable and rCBF change in 24 areas as the independent variable. Total MMSE score was significantly correlated only with the reduction of left hippocampal perfusion but not with right (P<0.01). Total MMSE score is an important indicator of left hippocampal function. (author)

  7. A comparative study of lattice Boltzmann and volume of fluid method for two dimensional multiphase flows

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seung Yeob [Korea Atomic Energy Research Institute (KAERI), Daejeon (Korea, Republic of); Ko, Sung Ho [Dept. of Mechanical Design Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2012-08-15

    The volume of fluid (VOF) model of FLUENT and the lattice Boltzmann method (LBM) are used to simulate two-phase flows. Both methods are validated for static and dynamic bubble test cases and then compared to experimental results. The VOF method does not reduce the spurious currents of the static droplet test and does not satisfy the Laplace law for small droplets at the acceptable level, as compared with the LBM. For single bubble flows, simulations are executed for various Eotvos numbers, Morton numbers and Reynolds numbers, and the results of both methods agree well with the experiments in the case of low Eotvos numbers. For high Eotvos numbers, the VOF results deviated from the experiments. For multiple bubbles, the bubble flow characteristics are related by the wake of the leading bubble. The coaxial and oblique coalescence of the bubbles are simulated successfully and the subsequent results are presented. In conclusion, the LBM performs better than the VOF method.

  8. Jackson System Development, Entity-relationship Analysis and Data Flow Models: a comparative study

    NARCIS (Netherlands)

    Wieringa, Roelf J.

    1994-01-01

    This report compares JSD with ER modeling and data flow modeling. It is shown that JSD can be combined with ER modeling and that the result is a richer method than either of the two. The resulting method can serve as a basis for a pratical object-oriented modeling method and has some resemblance to

  9. The Cost of Joint Replacement: Comparing Two Approaches to Evaluating Costs of Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L

    2018-02-21

    In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize

  10. Comparing flow-through and static ice cave models for Shoshone Ice Cave

    Directory of Open Access Journals (Sweden)

    Kaj E. Williams

    2015-05-01

    Full Text Available In this paper we suggest a new ice cave type: the “flow-through” ice cave. In a flow-through ice cave external winds blow into the cave and wet cave walls chill the incoming air to the wet-bulb temperature, thereby achieving extra cooling of the cave air. We have investigated an ice cave in Idaho, located in a lava tube that is reported to have airflow through porous wet end-walls and could therefore be a flow-through cave. We have instrumented the site and collected data for one year. In order to determine the actual ice cave type present at Shoshone, we have constructed numerical models for static and flow-through caves (dynamic is not relevant here. The models are driven with exterior measurements of air temperature, relative humidity and wind speed. The model output is interior air temperature and relative humidity. We then compare the output of both models to the measured interior air temperatures and relative humidity. While both the flow-through and static cave models are capable of preserving ice year-round (a net zero or positive ice mass balance, both models show very different cave air temperature and relative humidity output. We find the empirical data support a hybrid model of the static and flow-through models: permitting a static ice cave to have incoming air chilled to the wet-bulb temperature fits the data best for the Shoshone Ice Cave.

  11. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  12. Experiments in a flighted conveyor comparing shear rates in compressed versus free surface flows

    Science.gov (United States)

    Pohlman, Nicholas; Higgins, Hannah; Krupiarz, Kamila; O'Connor, Ryan

    2017-11-01

    Uniformity of granular flow rate is critical in industry. Experiments in a flighted conveyor system aim to fill a gap in knowledge of achieving steady mass flow rate by correlating velocity profile data with mass flow rate measurements. High speed images were collected for uniformly-shaped particles in a bottom-driven flow conveyor belt system from which the velocity profiles can be generated. The correlation of mass flow rates from the velocity profiles to the time-dependent mass measurements will determine energy dissipation rates as a function of operating conditions. The velocity profiles as a function of the size of the particles, speed of the belt, and outlet size, will be compared to shear rate relationships found in past experiments that focused on gravity-driven systems. The dimension of the linear shear and type of decaying transition to the stationary bed may appear different due to the compression versus dilation space in open flows. The application of this research can serve to validate simulations in discrete element modeling and physically demonstrate a process that can be further developed and customized for industry applications, such as feeding a biomass conversion reactor. Sponsored by NIU's Office of Student Engagement and Experiential Learning.

  13. On the coherence between high-energy total cross-section data when compared with general principles

    International Nuclear Information System (INIS)

    Gauron, P.; Nicolescu, B.; Paris-6 Univ., 75

    1993-12-01

    An essential model is performed - an independent study of the internal coherence between high-energy total cross-section data by using classes of functions satisfying general principles. The study is practically independent of the ρ-parameter values. This general analysis, made without any fit, reveals certain inconsistencies in the existing set of high-energy data. Some of these inconsistencies are eliminated by giving up arbitrary assumptions sometimes made in 'fitology'. It is shown that the ln 2 s increase of total cross-sections at high energies is clearly favoured when compared with other possible behaviours. (authors). 16 refs., 3 figs

  14. ChargeOut! : discounted cash flow compared with traditional machine-rate analysis

    Science.gov (United States)

    Ted Bilek

    2008-01-01

    ChargeOut!, a discounted cash-flow methodology in spreadsheet format for analyzing machine costs, is compared with traditional machine-rate methodologies. Four machine-rate models are compared and a common data set representative of logging skidders’ costs is used to illustrate the differences between ChargeOut! and the machine-rate methods. The study found that the...

  15. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  16. Comparative exploration of multidimensional flow cytometry software: a model approach evaluating T cell polyfunctional behavior.

    Science.gov (United States)

    Spear, Timothy T; Nishimura, Michael I; Simms, Patricia E

    2017-08-01

    Advancement in flow cytometry reagents and instrumentation has allowed for simultaneous analysis of large numbers of lineage/functional immune cell markers. Highly complex datasets generated by polychromatic flow cytometry require proper analytical software to answer investigators' questions. A problem among many investigators and flow cytometry Shared Resource Laboratories (SRLs), including our own, is a lack of access to a flow cytometry-knowledgeable bioinformatics team, making it difficult to learn and choose appropriate analysis tool(s). Here, we comparatively assess various multidimensional flow cytometry software packages for their ability to answer a specific biologic question and provide graphical representation output suitable for publication, as well as their ease of use and cost. We assessed polyfunctional potential of TCR-transduced T cells, serving as a model evaluation, using multidimensional flow cytometry to analyze 6 intracellular cytokines and degranulation on a per-cell basis. Analysis of 7 parameters resulted in 128 possible combinations of positivity/negativity, far too complex for basic flow cytometry software to analyze fully. Various software packages were used, analysis methods used in each described, and representative output displayed. Of the tools investigated, automated classification of cellular expression by nonlinear stochastic embedding (ACCENSE) and coupled analysis in Pestle/simplified presentation of incredibly complex evaluations (SPICE) provided the most user-friendly manipulations and readable output, evaluating effects of altered antigen-specific stimulation on T cell polyfunctionality. This detailed approach may serve as a model for other investigators/SRLs in selecting the most appropriate software to analyze complex flow cytometry datasets. Further development and awareness of available tools will help guide proper data analysis to answer difficult biologic questions arising from incredibly complex datasets. © Society

  17. Butter increased total and LDL cholesterol compared with olive oil but resulted in higher HDL cholesterol compared with a habitual diet

    DEFF Research Database (Denmark)

    Engel, Sara; Tholstrup, Tine

    2015-01-01

    BACKGROUND: Butter is known to have a cholesterol-raising effect and, therefore, has often been included as a negative control in dietary studies, whereas the effect of moderate butter intake has not been elucidated to our knowledge. OBJECTIVE: We compared the effects of moderate butter intake...... their habitual diets. The study included 47 healthy men and women (mean ± SD total cholesterol: 5.22 ± 0.90 mmol/L) who substituted a part of their habitual diets with 4.5% of energy from butter or refined olive oil. RESULTS: Study subjects were 70% women with a mean age and body mass index (in kg/m(2)) of 40.......4 y and 23.5, respectively. Butter intake increased total cholesterol and LDL cholesterol more than did olive oil intake (P cholesterol compared with the run-in period (P

  18. Comparing two surface flow wetlands for removal of nutrients in agricultural drainage water

    DEFF Research Database (Denmark)

    Hoffmann, Carl Christian; Kjærgaard, Charlotte; Levesen, Bo

    In Denmark there is a growing interest for using constructed wetlands as a mean for removal of nutrients from agricultural run-off, such as drainage ditches and tile drainage systems. We have studied two surface flow constructed wetlands from district Vejle, Jutland, Denmark. The Vicarage Wetland.......020 mg P and unfiltered TP decreases with 75 % to 0.040 mg P l-1. The results from this study seem to indicate that constructed surface flow wetlands are able to remove nitrogen and retain phosphorus from agricultural drainage run-off although the nutrient concentrations are much lower as compared...

  19. A comparative study of turbulence models for dissolved air flotation flow analysis

    International Nuclear Information System (INIS)

    Park, Min A; Lee, Kyun Ho; Chung, Jae Dong; Seo, Seung Ho

    2015-01-01

    The dissolved air flotation (DAF) system is a water treatment process that removes contaminants by attaching micro bubbles to them, causing them to float to the water surface. In the present study, two-phase flow of air-water mixture is simulated to investigate changes in the internal flow analysis of DAF systems caused by using different turbulence models. Internal micro bubble distribution, velocity, and computation time are compared between several turbulence models for a given DAF geometry and condition. As a result, it is observed that the standard κ-ε model, which has been frequently used in previous research, predicts somewhat different behavior than other turbulence models

  20. Effect of hypoxia on BOLD fMRI response and total cerebral blood flow in migraine with aura patients

    DEFF Research Database (Denmark)

    Arngrim, Nanna; Hougaard, Anders; Schytz, Henrik W

    2018-01-01

    was measured in the visual cortex ROIs V1-V5. Total cerebral blood flow (CBF) was calculated by measuring the blood velocity in the internal carotid arteries and the basilar artery using phase-contrast mapping (PCM) MRI. Hypoxia induced a greater decrease in BOLD response to visual stimulation in V1-V4 in MA......Experimentally induced hypoxia triggers migraine and aura attacks in patients suffering from migraine with aura (MA). We investigated the blood oxygenation level-dependent (BOLD) signal response to visual stimulation during hypoxia in MA patients and healthy volunteers. In a randomized double......-blind crossover study design, 15 MA patients were allocated to 180 min of normobaric poikilocapnic hypoxia (capillary oxygen saturation 70-75%) or sham (normoxia) on two separate days and 14 healthy volunteers were exposed to hypoxia. The BOLD functional MRI (fMRI) signal response to visual stimulation...

  1. Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty.

    Science.gov (United States)

    Sossai, D; Dagnino, G; Sanguineti, F; Franchin, F

    2011-12-01

    Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m(3)) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m(3) without the LAF to 3.5 CFU/m(3) with the LAF (P contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections.

  2. First Report of 90-Day Support of Two Calves with a Continuous-Flow Total Artificial Heart

    Science.gov (United States)

    Karimov, Jamshid H.; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A.; Fukamachi, Kiyotaka

    2015-01-01

    Objective The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. Methods CFTAH pumps have been implanted in 17 calves total. Hemodynamics, pump performance, and device-related adverse events were evaluated during studies and at necropsy. Results In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure [LAP], 16 ± 3 mm Hg; right atrial pressure [RAP], 17 ± 3 mm Hg; RAP-LAP difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three recent animals with the CFTAH recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last two were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. Conclusions The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. PMID:26173607

  3. Differentiation of chronic total occlusion and subtotal occlusion of the femoropopliteal artery-role of retrograde flow sign and collateral circulation on CT angiography images.

    Science.gov (United States)

    Zhang, Shujun; Su, Yanfei; Chen, Haisong

    2017-08-01

    To study the value of a retrograde flow sign and the collateral circulation on CT angiography (CTA) for the differential diagnosis of chronic total occlusion from subtotal occlusion of the femoropopliteal artery (FPA). 50 patients with obstruction of the FPA underwent CTA and digital subtraction angiography examinations of the lower limbs. The frequency of a retrograde flow sign and collateral circulation on CTA in chronic total and subtotal occlusion was noted and analyzed, with the results of digital subtraction angiography as a standard to judge total or subtotal occlusion. The decreasing CT value from the distal to proximal direction on CTA suggests the existence of retrograde flow. There were significant differences in the occurrence rates of a retrograde flow sign on CTA in the chronic total and subtotal obstruction groups (X 2 = 13.1, p collateral circulation sign (X 2 = 13.5, p collateral circulation sign to diagnose chronic total obstruction of the FPA had a sensitivity of 92.3% and specificity of 89.8%. The retrograde flow sign combined with a collateral circulation sign is of great clinical value for differentiation of chronic total stenosis from severe stenosis (subtotal occlusion) of the FPA. Advances in knowledge: A retrograde flow sign combined with a collateral circulation sign is of great clinical value to differentiate between chronic total stenosis and severe stenosis (subtotal occlusion) of the FPA.

  4. Adductor canal block with local infiltrative analgesia compared with local infiltrate analgesia for pain control after total knee arthroplasty

    OpenAIRE

    Xing, Qiujuan; Dai, Weiwei; Zhao, Dongfeng; Wu, Ji; Huang, Chunshui; Zhao, Yun

    2017-01-01

    Abstract Background: This meta-analysis aimed to evaluate the efficiency and safety of the combined adductor canal block with peri-articular infiltration versus periarticular infiltration alone for pain control after total knee arthroplasty (TKA). Methods: PubMed, Medline, Embase, Web of Science, and the Cochrane Library were searched to identify articles comparing the combined adductor canal block with peri-articular infiltration and periarticular infiltration alone for pain control after TK...

  5. Comparative study of wall-force models for the simulation of bubbly flows

    Energy Technology Data Exchange (ETDEWEB)

    Rzehak, Roland, E-mail: r.rzehak@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, POB 510119, D-01314 Dresden (Germany); Krepper, Eckhard, E-mail: E.Krepper@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Institute of Fluid Dynamics, POB 510119, D-01314 Dresden (Germany); Lifante, Conxita, E-mail: Conxita.Lifante@ansys.com [ANSYS Germany GmbH, Staudenfeldweg 12, 83624 Otterfing (Germany)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Comparison of common models for the wall force with an experimental database. Black-Right-Pointing-Pointer Identification of suitable closure for bubbly flow. Black-Right-Pointing-Pointer Enables prediction of location and height of wall peak in void fraction profiles. - Abstract: Accurate numerical prediction of void-fraction profiles in bubbly multiphase-flow relies on suitable closure models for the momentum exchange between liquid and gas phases. We here consider forces acting on the bubbles in the vicinity of a wall. A number of different models for this so-called wall-force have been proposed in the literature and are implemented in widely used CFD-codes. Simulations using a selection of these models are compared with a set of experimental data on bubbly air-water flow in round pipes of different diameter. Based on the results, recommendations on suitable closures are given.

  6. Comparative Study of Unsteady Flows in a Transonic Centrifugal Compressor with Vaneless and Vaned Diffusers

    Directory of Open Access Journals (Sweden)

    Cui Michael M.

    2005-01-01

    Full Text Available To reduce vibration and noise level, the impeller and diffuser blade numbers inside an industrial compressor are typically chosen without common divisors. The shapes of volutes or collectors in these compressors are also not axis-symmetric. When impeller blades pass these asymmetric structures, the flow field in the compressor is time-dependent and three-dimensional. To obtain a fundamental physical understanding of these three-dimensional unsteady flow fields and assess their impact on the compressor performance, the flow field inside the compressors needs to be studied as a whole to include asymmetric and unsteady interaction between the compressor components. In the current study, a unified three-dimensional numerical model was built for a transonic centrifugal compressor including impeller, diffusers, and volute. HFC 134a was used as the working fluid. The thermodynamic and transport properties of the refrigerant gas were modeled by the Martin-Hou equation of state and power laws, respectively. The three-dimensional unsteady flow field was simulated with a Navier-Stokes solver using the k−ϵ turbulent model. The overall performance parameters are obtained by integrating the field quantities. Both the unsteady flow field and the overall performance are analyzed comparatively for each component. The compressor was tested in a water chiller system instrumented to obtain both the overall performance data and local flow-field quantities. The experimental and numerical results agree well. The correlation between the overall compressor performance and local flow-field quantities is defined. The methodology developed and data obtained in these studies can be applied to the centrifugal compressor design and optimization.

  7. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  8. Determination Total Phosphour of Maize Plant Samples by Continuous Flow Analyzer in Comparison with Vanadium Molybdate Yellow Colorimetric Method

    Directory of Open Access Journals (Sweden)

    LIU Yun-xia

    2015-12-01

    Full Text Available The vanadium molybdate yellow colorimetric method(VMYC method is regarded as one of conventional methods for determining total phosphorus(P in plants, but it is time consuming procedure. Continuous flow analyzer(CFA is a fluid stream segmentation technique with air segments. It is used to measure P concentration based on the molybdate-antimony-ascorbic acid method of Murphy and Riley. Sixty nine of maize plant samples were selected and digested with H2SO4-H2O2. P concentrations in the digests were determined by CFA and VMYC method, respectively. The t test found that there was no any significant difference of the plant P contents measured by the CFA and the VMYC method. A linear equation could best describe their relationship: Y(CFA-P=0.927X(VMYC-P-0.002. The Pearson's correlation coefficient was 0.985 with a significance level(n=69, P<0.01. The CFA method for plant P measurement had a high precision with relative standard deviation(RSD less than 1.5%. It is suggested that the CFA based on Murphy and Riley colorimetric detection can be used to determinate total plant P in the digests solutions with H2SO4-H2O2. The CFA method is labor saving and can handle large numbers of samples. The human error in mixing with other operations is reduced to a great extent.

  9. Post-explant visualization of thrombi in outflow grafts and their junction to a continuous-flow total artificial heart using a high-definition miniaturized camera.

    Science.gov (United States)

    Karimov, Jamshid H; Horvath, David; Sunagawa, Gengo; Byram, Nicole; Moazami, Nader; Golding, Leonard A R; Fukamachi, Kiyotaka

    2015-12-01

    Post-explant evaluation of the continuous-flow total artificial heart in preclinical studies can be extremely challenging because of the device's unique architecture. Determining the exact location of tissue regeneration, neointima formation, and thrombus is particularly important. In this report, we describe our first successful experience with visualizing the Cleveland Clinic continuous-flow total artificial heart using a custom-made high-definition miniature camera.

  10. After total knee replacement younger patients demonstrate superior balance control compared to older patients when recovering from a forward fall.

    Science.gov (United States)

    Street, Brian D; Gage, William

    2017-05-01

    National joint replacement registries have reported a substantial growth in younger knee osteoarthritic patients (controlled perturbation have shown age-related differences between younger and older healthy adults, whether similar age-related differences exist among total knee replacement patients is unknown. A total of 59 participants, including 29 unilateral total knee replacement patients (six-months post-surgery) made up the four experimental groups: 1) younger patient (54.3 (SD 7.9) years), 2) younger control (55.2 (SD 4.0) years), 3) older patient (76.9 (SD 4.7) years), and 4) older control (77.7 (SD 4.1) years). Using a tether-release method to perturb balance and simulate a forward fall, center of mass and stepping characteristics were analyzed. Younger patients recovered following the perturbation with a significantly smaller center of mass displacement compared to the older patients (14.85 (SD 0.01) v. 18.13 (SD 0.02) %ht, p=0.02); utilizing a longer (0.43 (SD 0.02) v. 0.39 (SD 0.03) m, pcontrols in center of mass displacement or recovery step characteristics (p>0.05). The younger patients demonstrated superior center of mass control in response to a forward perturbation, suggesting that younger patients would be at a reduced risk of falling when recovering from a forward-directed postural perturbation compared to older patients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Distribution of microspheres to regions of dog lung compares well with regional flow of red blood cells

    International Nuclear Information System (INIS)

    Beck, K.C.; Rehder, K.

    1986-01-01

    Dorso-caudal areas of dog lungs are better perfused than ventral regions, independent of gravity. Could this be an artifact due to regional bias in lodging of MS. The costal surfaces of 5 isolated blood perfused left lungs of dogs [constant blood flow (F), Ppa, Ppv and Palv] were imaged (gamma camera) first after injection of 141 Ce-labeled MS (15 μ), then in 0.4 sec intervals after a bolus injection of 99 Tc-labeled red blood cells (RBC). Count rates were analyzed in 6 regions. Regional flow measured by MS (flowMS) is F times regional counts divided by total counts in the first image. Regional flow measured by RBC (flowRBC) is F times peak regional counts divided by peak total counts in the 0.4 sec images. The ratio flowMS/flow RBC was greater than 1.0 (P<0.001), suggesting a systematic difference between 1.0 (P<0.001), suggesting a systematic difference between flowMS and flow RBC. More importantly, there was no difference in flowMS/flow RBC among lung regions, allowing the authors to conclude there was no regional bias of flows

  12. Flow-injection determination of total organic fluorine with off-line defluorination reaction on a solid sorbent bed.

    Science.gov (United States)

    Musijowski, Jacek; Trojanowicz, Marek; Szostek, Bogdan; da Costa Lima, José Luis Fontes; Lapa, Rui; Yamashita, Hiroki; Takayanagi, Toshio; Motomizu, Shoji

    2007-09-26

    Considering recent reports on widespread occurrence and concerns about perfluoroalkyl substances (PFAS) in environmental and biological systems, analysis of these compounds have gained much attention in recent years. Majority of analyte-specific methods are based on a LC/MS/MS or a GC/MS detection, however many environmental or biological studies would benefit from a total organic fluorine (TOF) determination. Presented work was aimed at developing a method for TOF determination. TOF is determined as an amount of inorganic fluoride obtained after defluorination reaction conducted off-line using sodium biphenyl reagent directly on the sorbent without elution of retained analytes. Recovered fluoride was analyzed using flow-injection system with either fluorimetric or potentiometric detection. The TOF method was tested using perfluorocarboxylic acids (PFCA), including perfluorooctanoic acid (PFOA), as model compounds. Considering low concentrations of PFAS in natural samples, solid-phase extraction as a preconcentration procedure was evaluated. Several carbon-based sorbents were tested, namely multi-wall carbon nanotubes, carbon nanofibres and activated carbon. Good sorption of all analytes was achieved and defluorination reaction was possible to carry out directly on a sorbent bed. Recoveries obtained for PFCAs, adsorbed on an activated carbon sorbent, and measured as TOF, were 99.5+/-1.7, 110+/-9.4, 95+/-26, 120+/-32, 110+/-12 for C4, C6, C8, C10 and C12-PFCA, respectively. Two flow systems that would enable the defluorination reaction and fluoride determination in a single system were designed and tested.

  13. A CFD Case Study of a Fan Stage with Split Flow Path Subject to Total Pressure Distortion Inflow

    Science.gov (United States)

    To, Wai-Ming

    2017-01-01

    This report is the documentation of the work performed under the Hypersonic Project of the NASA's Fundamental Aeronautics Program. It was funded through Task Number NNC10E444T under GESS-2 Contract NNC06BA07B. The objective of the task is to develop advanced computational tools for the simulation of multi-stage turbomachinery in support of aeropropulsion. This includes work elements in extending the TURBO code and validating the multi-stage URANS (Unsteady Reynolds Averaged Navier Stokes) simulation results with the experimental data. The unsteady CFD (Computation Fluid Dynamics) calculations were performed in full wheel mode with and without screen generated total pressure distortion at the computational inflow boundary, as well as in single passage phase lag mode for uniform inflow. The experimental data were provided by NASA from the single stage RTA (Revolutionary Turbine Accelerator) fan test program.Significant non-uniform flow condition at the fan-face of the aeropropulsion system is frequentlyencountered in many of the advanced aerospace vehicles. These propulsion systems can be eithera podded or an embedded design employed in HWB (Hybrid Wing Body) airframe concept. It isalso a topic of interest in military applications, in which advanced air vehicles have already deployedsome form of embedded propulsion systems in their design because of the requirementsof compact and low observable inlets. Even in the conventional airframe/engine design, the fancould operate under such condition when the air vehicle is undergoing rapid maneuvering action.It is believed that a better understanding of the fan’s aerodynamic and aeromechanical responseto this type of operating condition or off design operation would be beneficial to designing distortiontolerant blades for improved engine operability.The objective for this research is to assess the capability of turbomachinery code as an analysistool in understanding the effects and evaluating the impact of flow distortion

  14. Saccharin and aspartame, compared with sucrose, induce greater weight gain in adult Wistar rats, at similar total caloric intake levels.

    Science.gov (United States)

    Feijó, Fernanda de Matos; Ballard, Cíntia Reis; Foletto, Kelly Carraro; Batista, Bruna Aparecida Melo; Neves, Alice Magagnin; Ribeiro, Maria Flávia Marques; Bertoluci, Marcello Casaccia

    2013-01-01

    It has been suggested that the use of nonnutritive sweeteners (NNSs) can lead to weight gain, but evidence regarding their real effect in body weight and satiety is still inconclusive. Using a rat model, the present study compares the effect of saccharin and aspartame to sucrose in body weight gain and in caloric intake. Twenty-nine male Wistar rats received plain yogurt sweetened with 20% sucrose, 0.3% sodium saccharin or 0.4% aspartame, in addition to chow and water ad libitum, while physical activity was restrained. Measurements of cumulative body weight gain, total caloric intake, caloric intake of chow and caloric intake of sweetened yogurt were performed weekly for 12 weeks. Results showed that addition of either saccharin or aspartame to yogurt resulted in increased weight gain compared to addition of sucrose, however total caloric intake was similar among groups. In conclusion, greater weight gain was promoted by the use of saccharin or aspartame, compared with sucrose, and this weight gain was unrelated to caloric intake. We speculate that a decrease in energy expenditure or increase in fluid retention might be involved. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Pneumatic sequential-compression boots compared with aspirin prophylaxis of deep-vein thrombosis after total knee arthroplasty.

    Science.gov (United States)

    Haas, S B; Insall, J N; Scuderi, G R; Windsor, R E; Ghelman, B

    1990-01-01

    This prospective, randomized study was undertaken to compare the effectiveness of pneumatic sequential-compression boots with that of aspirin in preventing deep-vein thrombosis after total knee arthroplasty. Patients were randomly assigned to one of two prophylactic regimens: compression boots or aspirin. One hundred and nineteen patients completed the study. Seventy-two patients had unilateral arthroplasty and forty-seven, one-stage bilateral arthroplasty. In the unilateral group, the incidence of deep-vein thrombosis was 22 per cent for the patients who used compression boots compared with 47 per cent for those who received aspirin (p less than 0.03). In the bilateral group, the incidence of deep-vein thrombosis was 48 per cent for the patients who used compression boots compared with 68 per cent for those who received aspirin (p less than 0.20). The results confirm the effectiveness of compression boots in the treatment of patients who have had unilateral total knee arthroplasty. Despite the use of compression boots, however, patients who had bilateral arthroplasty were at greater risk for the development of deep-vein thrombosis.

  16. An Integer Batch Scheduling Model for a Single Machine with Simultaneous Learning and Deterioration Effects to Minimize Total Actual Flow Time

    Science.gov (United States)

    Yusriski, R.; Sukoyo; Samadhi, T. M. A. A.; Halim, A. H.

    2016-02-01

    In the manufacturing industry, several identical parts can be processed in batches, and setup time is needed between two consecutive batches. Since the processing times of batches are not always fixed during a scheduling period due to learning and deterioration effects, this research deals with batch scheduling problems with simultaneous learning and deterioration effects. The objective is to minimize total actual flow time, defined as a time interval between the arrival of all parts at the shop and their common due date. The decision variables are the number of batches, integer batch sizes, and the sequence of the resulting batches. This research proposes a heuristic algorithm based on the Lagrange Relaxation. The effectiveness of the proposed algorithm is determined by comparing the resulting solutions of the algorithm to the respective optimal solution obtained from the enumeration method. Numerical experience results show that the average of difference among the solutions is 0.05%.

  17. An Integer Batch Scheduling Model for a Single Machine with Simultaneous Learning and Deterioration Effects to Minimize Total Actual Flow Time

    International Nuclear Information System (INIS)

    Yusriski, R; Sukoyo; Samadhi, T M A A; Halim, A H

    2016-01-01

    In the manufacturing industry, several identical parts can be processed in batches, and setup time is needed between two consecutive batches. Since the processing times of batches are not always fixed during a scheduling period due to learning and deterioration effects, this research deals with batch scheduling problems with simultaneous learning and deterioration effects. The objective is to minimize total actual flow time, defined as a time interval between the arrival of all parts at the shop and their common due date. The decision variables are the number of batches, integer batch sizes, and the sequence of the resulting batches. This research proposes a heuristic algorithm based on the Lagrange Relaxation. The effectiveness of the proposed algorithm is determined by comparing the resulting solutions of the algorithm to the respective optimal solution obtained from the enumeration method. Numerical experience results show that the average of difference among the solutions is 0.05%. (paper)

  18. Differences in total and allergen specific IgE during pregnancy compared with 1 month and 1 year post partum.

    Science.gov (United States)

    Perry, Lee M; Ownby, Dennis R; Wegienka, Ganesa R; Peterson, Edward L; Woodcroft, Kimberly J; Joseph, Christine L; Johnson, Christine C

    2009-10-01

    Pregnancy alters the function of many body systems, including the immune system. However, little is known regarding the effect of pregnancy on maternal IgE levels or atopy. To determine whether pregnancy consistently influences serum levels of total or allergen specific IgE. Blood samples were obtained from 764 women during the third trimester of pregnancy and 1 month post partum. A third sample was obtained from 106 of these women 1 year post partum. Samples were analyzed for total and specific IgE to 8 regionally common allergens using a commercially available system. Sensitization was defined as an allergen specific IgE level of 0.35 kU of allergen per liter or higher to any allergen. Total IgE increased significantly post partum, both at 1 month (40.36 vs 35.37 IU/mL intrapartum; P = .001) and at 1 year (44.97 vs 37.00 IU/mL intrapartum; P = .005). Allergen specific IgE decreased significantly at 1 month for cat, dog, ragweed, timothy grass, and egg (P = .001 to P = .02) but not for dust mite, cockroach, or Alternaria (P = .15 to P = .90). Similar patterns of change in total and specific IgE were seen at 1 year. However, on average, only 3.5% of participants changed sensitization status to the individual allergens studied during the 1 year of observation. Compared with intrapartum levels, total IgE levels increased significantly at 1 month and 1 year post partum. Conversely, at the same time points, IgE levels specific for common allergens significantly declined to most but not all allergens. Few women changed their sensitization status over 1 year.

  19. First report of 90-day support of 2 calves with a continuous-flow total artificial heart.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A R; Fukamachi, Kiyotaka

    2015-09-01

    The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  20. A Comparative Study of Simulated and Measured Gear-Flap Flow Interaction

    Science.gov (United States)

    Khorrami, Mehdi R.; Mineck, Raymond E.; Yao, Chungsheng; Jenkins, Luther N.; Fares, Ehab

    2015-01-01

    The ability of two CFD solvers to accurately characterize the transient, complex, interacting flowfield asso-ciated with a realistic gear-flap configuration is assessed via comparison of simulated flow with experimental measurements. The simulated results, obtained with NASA's FUN3D and Exa's PowerFLOW® for a high-fidelity, 18% scale semi-span model of a Gulfstream aircraft in landing configuration (39 deg flap deflection, main landing gear on and off) are compared to two-dimensional and stereo particle image velocimetry measurements taken within the gear-flap flow interaction region during wind tunnel tests of the model. As part of the bench-marking process, direct comparisons of the mean and fluctuating velocity fields are presented in the form of planar contour plots and extracted line profiles at measurement planes in various orientations stationed in the main gear wake. The measurement planes in the vicinity of the flap side edge and downstream of the flap trailing edge are used to highlight the effects of gear presence on tip vortex development and the ability of the computational tools to accurately capture such effects. The present study indicates that both computed datasets contain enough detail to construct a relatively accurate depiction of gear-flap flow interaction. Such a finding increases confidence in using the simulated volumetric flow solutions to examine the behavior of pertinent aer-odynamic mechanisms within the gear-flap interaction zone.

  1. Comparative studies of D2 receptors and cerebral blood flow in hemi-parkinsonism rats

    International Nuclear Information System (INIS)

    Lin, Y.; Lin, X.

    2000-01-01

    To study the relationship between dopamine (DA) D 2 receptors and cerebral blood flow in hemiparkinsonism rats. Hemi-parkinsonism rats were made by stereotaxic 6-hydroxy dopamine (6-OH-DA) lesions in substantia nigra and ventral tegmental area, apomorphine (Apo) which could induce the successful model rat rotates toward the intact side was used to screen that rats, 125 I-IBZM in vivo autoradiography and 99m Tc-HM-PAO regional brain biodistribution were used to study D 2 receptors and cerebral blood flow. The HPLC-ECD were used to measure the concentration of DA and it metabolites homovanillic acid (HVA), 3,4-dehydroxyphenyl acetic acid (DOPAC) in bilateral striatum (ST). The lesioned side ST DA and its metabolites HVA DOPAC reduced significantly than that of the intact side and pseudo-operated control group, ST/cerebellum (CB) 125 I-IBZM uptake ratio was 8.04 ±0.71 in lesioned side of hemi-parkinsonism rats, significantly increased compared with the intact side and the pseudo-operated group (p 99m Tc 30.1±4.53% enhancement as compared to the intact side, and also show good correlation with 30 min Apo induced rotation numbers (r=0.98), the regional cerebral blood flow study didn't show significant difference between bilateral brain cortex area (p>0.05). The DA content decreased significantly and induced an up-regulation of ST D 2 receptor binding sites in 6-OH-DA lesioned side in hemi-parkinsonism rats, the increased percentage of lesioned-intact side ST/CB 125 I-IBZM uptake ratio showed good correlation with rotation behavior induced by Apo. Compare with cerebral blood flow, D 2 receptor reflected by IBZM seems to be more specific and earlier to detect the cerebral functional impairment in experimental hemi-parkinsonism

  2. Salivary protein concentration, flow rate, buffer capacity and pH estimation: A comparative study among young and elderly subjects, both normal and with gingivitis and periodontitis.

    Science.gov (United States)

    Shaila, Mulki; Pai, G Prakash; Shetty, Pushparaj

    2013-01-01

    To evaluate the salivary protein concentration in gingivitis and periodontitis patients and compare the parameters like salivary total protein, salivary albumin, salivary flow rate, pH, buffer capacity and flow rate in both young and elderly patients with simple methods. One hundred and twenty subjects were grouped based on their age as young and elderly. Each group was subgrouped (20 subjects) as controls, gingivitis and periodontitis. Unstimulated whole saliva was collected from patients and flow rate was noted down during collection of the sample. Salivary protein estimation was done using the Biuret method and salivary albumin was assessed using the Bromocresol green method. pH was estimated with a pHmeter and buffering capacity was analyzed with the titration method. Student's t-test, Fisher's test (ANOVA) and Tukey HSD (ANOVA) tests were used for statistical analysis. A very highly significant rise in the salivary total protein and albumin concentration was noted in gingivitis and periodontitis subjects of both young and elderly. An overall decrease in salivary flow rate was observed among the elderly, and also the salivary flow rate of women was significantly lower than that of men. Significant associations between salivary total protein and albumin in gingivitis and periodontitis were found with simple biochemical tests. A decrease in salivary flow rate among elderly and among women was noted.

  3. Ten-year results of a randomized clinical trial comparing radical mastectomy and total mastectomy with or without radiation

    International Nuclear Information System (INIS)

    Fisher, B.; Redmond, C.; Fisher, E.R.

    1985-01-01

    In 1971 a randomized trial was begun to compare alternative local and regional treatments of breast cancer, all of which employ breast removal. Life-table estimates were obtained for 1665 women enrolled in the study for a mean of 126 months. There were no significant differences among three groups of patients with clinically negative auxillary nodes, with respect to disease-free survival, distant-disease-free survival, or overall survival (about 57%) at 10 years. The patients were treated by radical mastectomy, total (simple) mastectomy without auxillary dissection but with regional irradiation, or total mastectomy without irradiation plus auxillary dissection only if nodes were subsequently positive. Similarly, no differences, were observed between patients with clinically positive nodes treated by radical mastectomy or by total mastectomy without auxillary dissection but with regional irradiation. Survival at 10 years was about 38% in both groups. Our findings indicate that the location of a breast tumor does not influence the prognosis and that irradiation of internal mammary nodes in patients with inner-quadrant lesions does not improve survival. The data also demonstrate that the results obtained at five years accurately predict the outcome at 10 years. It was concluded that the variations of local and regional treatment used in this study are not important in determining survival of patients with breast cancer. 25 references, 6 figures, 1 table

  4. Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques.

    Science.gov (United States)

    Hampp, Emily L; Chughtai, Morad; Scholl, Laura Y; Sodhi, Nipun; Bhowmik-Stoker, Manoshi; Jacofsky, David J; Mont, Michael A

    2018-05-01

    This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements ( p  ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements ( p  ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. The effects of anti-hypertensives and type 2 diabetes on salivary flow and total antioxidant capacity.

    Science.gov (United States)

    Djukić, L J; Roganović, J; Brajović, M D; Bokonjić, D; Stojić, D

    2015-07-01

    The present cross-sectional study aimed to determine the effect of first-line anti-hypertensive drugs (enalapril, metoprolol, and combinations of enalapril with metoprolol and/or hydrochlorothiazide) on salivary gland function and salivary total antioxidant capacity (TAC) in hypertensive patients with/without diabetes mellitus (DM) type 2. Salivary gland function was measured as xerostomia (interview) and unstimulated whole saliva flow rate (UWSFR) in 447 subjects (387 hypertensive and 60 healthy). Salivary TAC was evaluated by spectrophotometric assay. Enalapril is not xerogenic, while metoprolol and drug combinations are. In the presence of DM type 2, all drugs, except metoprolol, had pronounced xerogenic effect. Binary logistic regression analysis found enalapril to be significantly associated with decreased risk of xerogenic effect development, while DM type 2 with increased risk. In the presence of enalapril in hypertensive patients with/without DM type 2 salivary TAC was similar to that in healthy subjects, while for metoprolol was reduced. Enalapril is not xerogenic but is antioxidant, which moderately reduces the risk of xerogenic effect development even in the presence of DM type 2. However, metoprolol and drug combinations exhibit xerogenic effect. In DM type 2, xerogenic effect of all drugs was pronounced except of metoprolol. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. The use of flow cytometry to accurately ascertain total and viable counts of Lactobacillus rhamnosus in chocolate.

    Science.gov (United States)

    Raymond, Yves; Champagne, Claude P

    2015-04-01

    The goals of this study were to evaluate the precision and accuracy of flow cytometry (FC) methodologies in the evaluation of populations of probiotic bacteria (Lactobacillus rhamnosus R0011) in two commercial dried forms, and ascertain the challenges in enumerating them in a chocolate matrix. FC analyses of total (FC(T)) and viable (FC(V)) counts in liquid or dried cultures were almost two times more precise (reproducible) than traditional direct microscopic counts (DCM) or colony forming units (CFU). With FC, it was possible to ascertain low levels of dead cells (FC(D)) in fresh cultures, which is not possible with traditional CFU and DMC methodologies. There was no interference of chocolate solids on FC counts of probiotics when inoculation was above 10(7) bacteria per g. Addition of probiotics in chocolate at 40 °C resulted in a 37% loss in viable cells. Blending of the probiotic powder into chocolate was not uniform which raised a concern that the precision of viable counts could suffer. FCT data can serve to identify the correct inoculation level of a sample, and viable counts (FCV or CFU) can subsequently be better interpreted. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  7. Flow Cytometry Total Cell Counts: A Field Study Assessing Microbiological Water Quality and Growth in Unchlorinated Drinking Water Distribution Systems

    Science.gov (United States)

    Liu, G.; Van der Mark, E. J.; Verberk, J. Q. J. C.; Van Dijk, J. C.

    2013-01-01

    The objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs) as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A one-year sampling program was carried out in two distribution systems in The Netherlands. Results demonstrated that, in both systems, the biomass differences measured by ATP were not significant. TCC differences were also not significant in treatment plant 1, but decreased slightly in treatment plant 2. TCC values were found to be higher at temperatures above 15°C than at temperatures below 15°C. The correlation study of parameters describing biostability found no relationship among TCC, heterotrophic plate counts, and Aeromonas. Also no relationship was found between TCC and ATP. Some correlation was found between the subgroup of high nucleic acid content bacteria and ATP (R 2 = 0.63). Overall, the results demonstrated that TCC is a valuable parameter to assess the drinking water biological quality and regrowth; it can directly and sensitively quantify biomass, detect small changes, and can be used to determine the subgroup of active HNA bacteria that are related to ATP. PMID:23819117

  8. Flow Cytometry Total Cell Counts: A Field Study Assessing Microbiological Water Quality and Growth in Unchlorinated Drinking Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    G. Liu

    2013-01-01

    Full Text Available The objective of this study was to evaluate the application of flow cytometry total cell counts (TCCs as a parameter to assess microbial growth in drinking water distribution systems and to determine the relationships between different parameters describing the biostability of treated water. A one-year sampling program was carried out in two distribution systems in The Netherlands. Results demonstrated that, in both systems, the biomass differences measured by ATP were not significant. TCC differences were also not significant in treatment plant 1, but decreased slightly in treatment plant 2. TCC values were found to be higher at temperatures above 15°C than at temperatures below 15°C. The correlation study of parameters describing biostability found no relationship among TCC, heterotrophic plate counts, and Aeromonas. Also no relationship was found between TCC and ATP. Some correlation was found between the subgroup of high nucleic acid content bacteria and ATP (R2=0.63. Overall, the results demonstrated that TCC is a valuable parameter to assess the drinking water biological quality and regrowth; it can directly and sensitively quantify biomass, detect small changes, and can be used to determine the subgroup of active HNA bacteria that are related to ATP.

  9. Comparative studies of D2 receptors and cerebral blood flow in hemi-Parkinsonism rats

    International Nuclear Information System (INIS)

    Lin Yansong; Lin Xiangtong

    2000-01-01

    Objective: To study the relationship between dopamine D 2 receptors and cerebral blood flow in hemi-Parkinsonism rats. Methods: Hemi-Parkinsonism rats were made by stereotaxic 6-hydroxy dopamine (6-OH-DA) lesions in substantia nigra and ventral tegmental area, apomorphine (Apo) which could induce the successful model rat to rotate toward the intact side was used to select the rat models, 125 I-IBZM in vivo autoradiography and 99 Tc m -HMPAO regional cerebral biodistribution analysis were used to study D 2 receptors and cerebral blood flow. The HPLC-ECD was used to measure striatum DA and its metabolite content . Results: the lesioned side striatum DA and its metabolites homovanillic acid (HVA) 3,4-dihyroxy-phenylacetic acid (DOPAC) reduced significantly than that of the intact side and pseudo-operated group, striatum/cerebellum 125 I-IBZM uptake ratio was 8.04 +- 0.71 in lesioned side of hemi-Parkinsonism rats, significantly increased compared with the intact side and the pseudo-operated group (P 0.05). Conclusions: the 6-OH-DA lesioned side DA content decreased significantly and thus induced a compensative up-regulation of striatum D 2 receptor binding sites in hemi-Parkinsonism rats, which show good correlation with rotation behavior induced by Apo. Comparing with cerebral blood flow, D 2 receptor reflected by IBZM seems to be more specific and earlier to detect the cerebral functional impairment in experimental hemi-Parkinsonism

  10. Comparative Simulation Study of Production Scheduling in the Hybrid and the Parallel Flow

    Directory of Open Access Journals (Sweden)

    Varela Maria L.R.

    2017-06-01

    Full Text Available Scheduling is one of the most important decisions in production control. An approach is proposed for supporting users to solve scheduling problems, by choosing the combination of physical manufacturing system configuration and the material handling system settings. The approach considers two alternative manufacturing scheduling configurations in a two stage product oriented manufacturing system, exploring the hybrid flow shop (HFS and the parallel flow shop (PFS environments. For illustrating the application of the proposed approach an industrial case from the automotive components industry is studied. The main aim of this research to compare results of study of production scheduling in the hybrid and the parallel flow, taking into account the makespan minimization criterion. Thus the HFS and the PFS performance is compared and analyzed, mainly in terms of the makespan, as the transportation times vary. The study shows that the performance HFS is clearly better when the work stations’ processing times are unbalanced, either in nature or as a consequence of the addition of transport times just to one of the work station processing time but loses advantage, becoming worse than the performance of the PFS configuration when the work stations’ processing times are balanced, either in nature or as a consequence of the addition of transport times added on the work stations’ processing times. This means that physical layout configurations along with the way transport time are including the work stations’ processing times should be carefully taken into consideration due to its influence on the performance reached by both HFS and PFS configurations.

  11. Representing macropore flow at the catchment scale: a comparative modeling study

    Science.gov (United States)

    Liu, D.; Li, H. Y.; Tian, F.; Leung, L. R.

    2017-12-01

    Macropore flow is an important hydrological process that generally enhances the soil infiltration capacity and velocity of subsurface water. Up till now, macropore flow is mostly simulated with high-resolution models. One possible drawback of this modeling approach is the difficulty to effectively represent the overall typology and connectivity of the macropore networks. We hypothesize that modeling macropore flow directly at the catchment scale may be complementary to the existing modeling strategy and offer some new insights. Tsinghua Representative Elementary Watershed model (THREW model) is a semi-distributed hydrology model, where the fundamental building blocks are representative elementary watersheds (REW) linked by the river channel network. In THREW, all the hydrological processes are described with constitutive relationships established directly at the REW level, i.e., catchment scale. In this study, the constitutive relationship of macropore flow drainage is established as part of THREW. The enhanced THREW model is then applied at two catchments with deep soils but distinct climates, the humid Asu catchment in the Amazon River basin, and the arid Wei catchment in the Yellow River basin. The Asu catchment has an area of 12.43km2 with mean annual precipitation of 2442mm. The larger Wei catchment has an area of 24800km2 but with mean annual precipitation of only 512mm. The rainfall-runoff processes are simulated at a hourly time step from 2002 to 2005 in the Asu catchment and from 2001 to 2012 in the Wei catchment. The role of macropore flow on the catchment hydrology will be analyzed comparatively over the Asu and Wei catchments against the observed streamflow, evapotranspiration and other auxiliary data.

  12. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study.

    Science.gov (United States)

    Kamate, Wasim Ismail; Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-04-01

    Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester , third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third trimester and postpartum period. These

  13. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study

    Science.gov (United States)

    Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-01-01

    Introduction Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. Aim The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. Materials and Methods A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Results Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester, third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third

  14. Comparing the Titrations of Mixed-Acid Solutions Using Dropwise and Constant-Flow Techniques

    Science.gov (United States)

    Charlesworth, Paul; Seguin, Matthew J.; Chesney, David J.

    2003-11-01

    A mixed-acid solution containing hydrochloric and phosphoric acids was used to determine the error associated with performing a real-time titration. The results were compared against those obtained by performing the titration in a more traditional dropwise addition of titrant near the equivalence points. It was found that the real-time techniques resulted in significantly decreased analysis times while maintaining a low experimental error. The constant-flow techniques were implemented into two different levels of chemistry. It was found that students could successfully utilize the modified experiments. Problems associated with the techniques, major sources of error, and their solutions are discussed. In both cases, the use of the constant-flow setup has increased student recollection of key concepts, such as pKa determination, proper indicator choice, and recognizing the shape of specific titration curves by increasing student interest in the experiment.

  15. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    Science.gov (United States)

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero

  16. End-tidal control vs. manually controlled minimal-flow anesthesia: a prospective comparative trial.

    Science.gov (United States)

    Wetz, A J; Mueller, M M; Walliser, K; Foest, C; Wand, S; Brandes, I F; Waeschle, R M; Bauer, M

    2017-11-01

    To ensure safe general anesthesia, manually controlled anesthesia requires constant monitoring and numerous manual adjustments of the gas dosage, especially for low- and minimal-flow anesthesia. Oxygen flow-rate and administration of volatile anesthetics can also be controlled automatically by anesthesia machines using the end-tidal control technique, which ensures constant end-tidal concentrations of oxygen and anesthetic gas via feedback and continuous adjustment mechanisms. We investigated the hypothesis that end-tidal control is superior to manually controlled minimal-flow anesthesia (0.5 l/min). In this prospective trial, we included 64 patients undergoing elective surgery under general anesthesia. We analyzed the precision of maintenance of the sevoflurane concentration (1.2-1.4%) and expiratory oxygen (35-40%) and the number of necessary adjustments. Target-concentrations of sevoflurane and oxygen were maintained at more stable levels with the use of end-tidal control (during the first 15 min 28% vs. 51% and from 15 to 60 min 1% vs. 19% deviation from sevoflurane target, P tidal oxygen (5, IQR 3-6). The target-concentrations were reached earlier with the use of end-tidal compared with manual controlled minimal-flow anesthesia but required slightly greater use of anesthetic agents (6.9 vs. 6.0 ml/h). End-tidal control is a superior technique for setting and maintaining oxygen and anesthetic gas concentrations in a stable and rapid manner compared with manual control. Consequently, end-tidal control can effectively support the anesthetist. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Review: Autologous blood transfusion drainage compared with no drainage in total knee arthroplasty: A meta-analysis and systematic review.

    Science.gov (United States)

    Hong, Kun-Hao; Pan, Jian-Ke; Xie, Hui; Guo, Da; Yang, Wei-Yi; Su, Hai-Tao; Xu, Shu-Chai; Liu, Jun

    2017-11-01

    This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with no drainage which is controversial in total knee arthroplasty (TKA).A comprehensive literature search was carried out in March 2015 using the PubMed, Embase, and Cochrane Library databases. A metaanalysis was carried out on two retrospective comparative studies (RCSs) and five randomized controlled trials (RCTs). The number of patients receiving homologous blood transfusion was the primary outcome of the meta-analysis; the secondary outcome measure was the mean drop in Hb level in comparison to the mean pre-operative HB level, the range of flexion of the knee joint, and infections of the wound after surgery. A total of 868 patients, who were included in two retrospective studies and five RCTs, were distributed into subgroups for the meta-analysis. This pooled data showed no benefit of ABT drainage compared no drainage in the homologous blood transfusion rate (13.05% and 16.91%, OR:0.73[0.47,1.13], Z=1.41, P=0.016; and 3.49% and 6.54%, OR: 0.50[0.12,2.01], Z=0.98,P=0.033,respectively in subgroups), Hb drop (Weight mean differences (WMD): 0.20[-0.28,0.68], Z=0.82, P=0.41; WMD:0.16[-0.41,0.55], Z=0.93, P=0.35, respectively), range of flexion of the knee joint (WMD:-0.82 [-3.35,1.70], Z =0.64,P=0.52)and wound infection (OR:0.25[0.61,10.20]; Z =1.28, p=0.2) after TKA surgery. Our findings do not recommend the routine use of postoperative ABT drainage in total knee arthroplasty. Well-designed RCTs with large sample sizes, longer term measures and extensive follow-up period should be performed in the future to update the findings of this study.

  18. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  19. Precipitation and total power consumption in the ionosphere: Global MHD simulation results compared with Polar and SNOE observations

    Directory of Open Access Journals (Sweden)

    M. Palmroth

    2006-05-01

    Full Text Available We compare the ionospheric electron precipitation morphology and power from a global MHD simulation (GUMICS-4 with direct measurements of auroral energy flux during a pair of substorms on 28-29 March 1998. The electron precipitation power is computed directly from global images of auroral light observed by the Polar satellite ultraviolet imager (UVI. Independent of the Polar UVI measurements, the electron precipitation energy is determined from SNOE satellite observations on the thermospheric nitric oxide (NO density. We find that the GUMICS-4 simulation reproduces the spatial variation of the global aurora rather reliably in the sense that the onset of the substorm is shown in GUMICS-4 simulation as enhanced precipitation in the right location at the right time. The total integrated precipitation power in the GUMICS-4 simulation is in quantitative agreement with the observations during quiet times, i.e., before the two substorm intensifications. We find that during active times the GUMICS-4 integrated precipitation is a factor of 5 lower than the observations indicate. However, we also find factor of 2-3 differences in the precipitation power among the three different UVI processing methods tested here. The findings of this paper are used to complete an earlier objective, in which the total ionospheric power deposition in the simulation is forecasted from a mathematical expression, which is a function of solar wind density, velocity and magnetic field. We find that during this event, the correlation coefficient between the outcome of the forecasting expression and the simulation results is 0.83. During the event, the simulation result on the total ionospheric power deposition agrees with observations (correlation coefficient 0.8 and the AE index (0.85.

  20. Comparing survival outcomes of gross total resection and subtotal resection with radiotherapy for craniopharyngioma: a meta-analysis.

    Science.gov (United States)

    Wang, Guoqing; Zhang, Xiaoyang; Feng, Mengzhao; Guo, Fuyou

    2018-06-01

    Recent studies suggest that subtotal resection (STR) followed by radiation therapy (RT) is an appealing alternative to gross total resection (GTR) for craniopharyngioma, but it remains controversial. We conducted a meta-analysis to determine whether GTR is superior to STR with RT for craniopharyngioma. A systematic search was performed for articles published until October 2017 in the PubMed, Embase, and Cochrane Central databases. The endpoints of interest are overall survival and progression-free survival. Pooled hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) were calculated using a fixed or random-effects model. The data were analyzed using Review Manager 5.3 software. A total of 744 patients (seven cohort studies) were enrolled for analyses. There were no significant differences between the GTR and STR with RT groups when the authors compared the pooled HRs at the end of the follow-up period. Overall survival (pooled HR = 0.76, 95% CI: 0.46-1.25, P = 0.28) and progression-free survival (pooled HR = 1.52, 95% CI: 0.42-5.44, P = 0.52) were similar between the two groups. The current meta-analysis suggests that GTR and STR with RT have the similar survival outcomes for craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Comparing the effects of fluoxetine and imipramine on total cholesterol, triglyceride, and weight in patients with major depression

    Directory of Open Access Journals (Sweden)

    Shahsavand Ananloo Esmaeil

    2013-01-01

    Full Text Available Abstract Background There are some reports on the effects of antidepressants on metabolic syndrome. However, our search in the previously published literature showed a lack of information on the comparison of the effects of different classes of antidepressants on lipid profile. Therefore, this study was aimed to compare the effects of fluoxetine and imipramine on serum total cholesterol (TC and triglyceride (TG as well as body weight (BW in patients with major depressive disorder. Methods Fifty one patients, 18 to 70 years of age, with major depressive disorder complied with the criteria of this preliminary, open-label clinical trial. Subjects received either imipramine (75–200 mg/day or fluoxetine (20–40 mg/day for 8 weeks. Total cholesterol and TG levels, as well as BW were compared at baseline with those at weeks 4 and 8. Data was analyzed by SPSS software version 16.0. Results In the fluoxetine group, TC levels decreased from 165.71 mg/dL to 156.71 mg/dL at week 4 (P = 0.07, and to 143.94 mg/dL at week 8 (P = 0.16; TG levels decreased from 129.35 mg/dL to 115.88 mg/dL at week 4 (P Repeated measures ANOVA showed significant effects on both TC and TG levels as well as on BW in all patients receiving imipramine. However, in patients on fluoxetine, repeated measures ANOVA showed significant effects of this medication only on TC levels in males. Conclusions Monitoring TC and TG and BW is recommended before starting imipramine in depressed patients with increased risk for cardiovascular disease. Fluoxetine may be the preferred agent in those with high or borderline high lipid levels.

  2. Resource efficiency of urban sanitation systems. A comparative assessment using material and energy flow analysis

    Energy Technology Data Exchange (ETDEWEB)

    Meinzinger, Franziska

    2010-07-01

    Within the framework of sustainable development it is important to find ways of reducing natural resource consumption and to change towards closed-loop management. As in many other spheres increased resource efficiency has also become an important issue in sanitation. Particularly nutrient recovery for agriculture, increased energy-efficiency and saving of natural water resources, can make a contribution to more resource efficient sanitation systems. To assess the resource efficiency of alternative developments a systems perspective is required. The present study applies a combined cost, energy and material flow analysis (ceMFA) as a system analysis method to assess the resource efficiency of urban sanitation systems. This includes the discussion of relevant criteria and assessment methods. The main focus of this thesis is the comparative assessment of different systems, based on two case studies; Hamburg in Germany and Arba Minch in Ethiopia. A range of possible system developments including source separation (e.g. diversion of urine or blackwater) is defined and compared with the current situation as a reference system. The assessment is carried out using computer simulations based on model equations. The model equations not only integrate mass and nutrient flows, but also the energy and cost balances of the different systems. In order to assess the impact of different assumptions and calculation parameters, sensitivity analyses and parameter variations complete the calculations. Based on the simulations, following general conclusions can be drawn: None of the systems show an overall benefit with regard to all investigated criteria, namely nutrients, energy, water and costs. Yet, the results of the system analysis can be used as basis for decision making if a case-related weighting is introduced. The systems show varying potential for the recovery of nutrients from (source separated) wastewater flows. For the case study of Hamburg up to 29% of the mineral

  3. Comparative studies of method for determining total mercury in fish. Dithizone and flameless atomic absorption spectrophotometry techniques

    International Nuclear Information System (INIS)

    Protasowicki, M.; Ociepa, A.; Chodyniecki, A.

    1977-01-01

    Two methods for determining total mercury in fish were compared: the dithizone and flameless atomic absorption spectrophotometry techniques. The studies involved determination of recovery when 1μg of mercury as solutions of HgCl 2 or CH 3 HgC were added to each sample of herring flesh. Mean recoveries in the dithizone method were found to be 91.4+-7.47% and 90.25+-4.73% for the two solutions respectively, while the recoveries obtained with the flameless atomic absorption spectrophotometry were 95.00+-9.13% and 98.70+-7.14%, respectively. Both techniques were used to determine the mercury content in the same herring flesh sample. The first technique showed the content of 0.050+-0.018μg Hg g -1 while the result obtained with the other one was 0.062+-0.013μg Hg g -1 . The statistical treatment of the results obtained showed no difference between the two techniques, the significance level being α=0.05. Therefore, the results obtained with the dithizone method are comparable with those obtained with the flameless atomic absorption spectrophotometry for mercury contents of the magnitude order of 0.050 ug.g -1 . (author)

  4. Polyamines: total daily intake in adolescents compared to the intake estimated from the Swedish Nutrition Recommendations Objectified (SNO

    Directory of Open Access Journals (Sweden)

    Mohamed Atiya Ali

    2011-01-01

    Full Text Available Background: Dietary polyamines have been shown to give a significant contribution to the body pool of polyamines. Knowing the levels of polyamines (putrescine, spermidine, and spermine in different foods and the contribution of daily food choice to polyamine intake is of interest, due to the association of these bioactive amines to health and disease. Objective: To estimate polyamine intake and food contribution to this intake in adolescents compared to a diet fulfilling the Swedish Nutrition Recommendations. Design: A cross-sectional study of dietary intake in adolescents and an ‘ideal diet’ (Swedish nutrition recommendations objectified [SNO] list of foods was used to compute polyamine intake using a database of polyamine contents of foods. For polyamine intake estimation, 7-day weighed food records collected from 93 adolescents were entered into dietetic software (Dietist XP including data on polyamine contents of foods. The content of polyamines in foods recommended according to SNO was entered in the same way. Results: The adolescents’ mean daily polyamine intake was 316±170 µmol/day, while the calculated contribution according to SNO was considerably higher with an average polyamine intake of 541 µmol/day. In both adolescent's intake and SNO, fruits contributed to almost half of the total polyamine intake. The reason why the intake among the adolescents was lower than the one calculated from SNO was mainly due to the low vegetable consumption in the adolescents group. Conclusions: The average daily total polyamine intake was similar to that previously reported in Europe. With an ‘ideal’ diet according to Swedish nutrition recommendations, the intake of this bioactive non-nutrient would be higher than that reported by our adolescents and also higher than that previously reported from Europe.

  5. Total cost of ownership of electric vehicles compared to conventional vehicles: A probabilistic analysis and projection across market segments

    International Nuclear Information System (INIS)

    Wu, Geng; Inderbitzin, Alessandro; Bening, Catharina

    2015-01-01

    While electric vehicles (EV) can perform better than conventional vehicles from an environmental standpoint, consumers perceive them to be more expensive due to their higher capital cost. Recent studies calculated the total cost of ownership (TCO) to evaluate the complete cost for the consumer, focusing on individual vehicle classes, powertrain technologies, or use cases. To provide a comprehensive overview, we built a probabilistic simulation model broad enough to capture most of a national market. Our findings indicate that the comparative cost efficiency of EV increases with the consumer's driving distance and is higher for small than for large vehicles. However, our sensitivity analysis shows that the exact TCO is subject to the development of vehicle and operating costs and thus uncertain. Although the TCO of electric vehicles may become close to or even lower than that of conventional vehicles by 2025, our findings add evidence to past studies showing that the TCO does not reflect how consumers make their purchase decision today. Based on these findings, we discuss policy measures that educate consumers about the TCO of different vehicle types based on their individual preferences. In addition, measures improving the charging infrastructure and further decreasing battery cost are discussed. - Highlights: • Calculates the total cost of ownership across competing vehicle technologies. • Uses Monte Carlo simulation to analyse distributions and probabilities of outcomes. • Contains a comprehensive assessment across the main vehicle classes and use cases. • Indicates that cost efficiency of technology depends on vehicle class and use case. • Derives specific policy measures to facilitate electric vehicle diffusion

  6. Comparative analysis of von Willebrand factor profiles after implantation of left ventricular assist device and total artificial heart.

    Science.gov (United States)

    Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O

    2017-08-01

    Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and

  7. Comparative analysis of several sediment transport formulations applied to dam-break flows over erodible beds

    Science.gov (United States)

    Cea, Luis; Bladé, Ernest; Corestein, Georgina; Fraga, Ignacio; Espinal, Marc; Puertas, Jerónimo

    2014-05-01

    Transitory flows generated by dam failures have a great sediment transport capacity, which induces important morphological changes on the river topography. Several studies have been published regarding the coupling between the sediment transport and hydrodynamic equations in dam-break applications, in order to correctly model their mutual interaction. Most of these models solve the depth-averaged shallow water equations to compute the water depth and velocity. On the other hand, a wide variety of sediment transport formulations have been arbitrarily used to compute the topography evolution. These are based on semi-empirical equations which have been calibrated under stationary and uniform conditions very different from those achieved in dam-break flows. Soares-Frazao et al. (2012) proposed a Benchmark test consisting of a dam-break over a mobile bed, in which several teams of modellers participated using different numerical models, and concluded that the key issue which still needs to be investigated in morphological modelling of dam-break flows is the link between the solid transport and the hydrodynamic variables. This paper presents a comparative analysis of different sediment transport formulations applied to dam-break flows over mobile beds. All the formulations analysed are commonly used in morphological studies in rivers, and include the formulas of Meyer-Peter & Müller (1948), Wong-Parker (2003), Einstein-Brown (1950), van Rijn (1984), Engelund-Hansen (1967), Ackers-White (1973), Yang (1973), and a Meyer-Peter & Müller type formula but with ad-hoc coefficients. The relevance of corrections on the sediment flux direction and magnitude due to the bed slope and the non-equilibrium hypothesis is also analysed. All the formulations have been implemented in the numerical model Iber (Bladé et al. (2014)), which solves the depth-averaged shallow water equations coupled to the Exner equation to evaluate the bed evolution. Two different test cases have been

  8. Cost-utility analysis comparing radioactive iodine, anti-thyroid drugs and total thyroidectomy for primary treatment of Graves' disease.

    Science.gov (United States)

    Donovan, Peter J; McLeod, Donald S A; Little, Richard; Gordon, Louisa

    2016-12-01

    Little data is in existence about the most cost-effective primary treatment for Graves' disease. We performed a cost-utility analysis comparing radioactive iodine (RAI), anti-thyroid drugs (ATD) and total thyroidectomy (TT) as first-line therapy for Graves' disease in England and Australia. We used a Markov model to compare lifetime costs and benefits (quality-adjusted life-years (QALYs)). The model included efficacy, rates of relapse and major complications associated with each treatment, and alternative second-line therapies. Model parameters were obtained from published literature. One-way sensitivity analyses were conducted. Costs were presented in 2015£ or Australian Dollars (AUD). RAI was the least expensive therapy in both England (£5425; QALYs 34.73) and Australia (AUD5601; 30.97 QALYs). In base case results, in both countries, ATD was a cost-effective alternative to RAI (£16 866; 35.17 QALYs; incremental cost-effectiveness ratio (ICER) £26 279 per QALY gained England; AUD8924; 31.37 QALYs; ICER AUD9687 per QALY gained Australia), while RAI dominated TT (£7115; QALYs 33.93 England; AUD15 668; 30.25 QALYs Australia). In sensitivity analysis, base case results were stable to changes in most cost, transition probabilities and health-relative quality-of-life (HRQoL) weights; however, in England, the results were sensitive to changes in the HRQoL weights of hypothyroidism and euthyroidism on ATD. In this analysis, RAI is the least expensive choice for first-line treatment strategy for Graves' disease. In England and Australia, ATD is likely to be a cost-effective alternative, while TT is unlikely to be cost-effective. Further research into HRQoL in Graves' disease could improve the quality of future studies. © 2016 European Society of Endocrinology.

  9. Superior long-term survival for fixed bearing compared with mobile bearing in ligament-balanced total knee arthroplasty.

    Science.gov (United States)

    Heesterbeek, P J C; van Houten, A H; Klenk, J S; Eijer, H; Christen, B; Wymenga, A B; Schuster, A J

    2018-05-01

    Only few long-term data on ligament-balanced cruciate-retaining total knee arthroplasty (CR TKA) are currently available. Either a mobile- or fixed-bearing insert can be chosen, which showed good mid-term outcome and few complications and revisions. This multi-centre retrospective cross-sectional cohort study investigated the 12-year results of primary TKA using a balancing gap technique and compared survival and clinical outcome between fixed and mobile inserts. In this retrospective cross-sectional cohort study, 557 cases of three clinics (2 Swiss, 1 Dutch) operated between 1998 and 2003 with the first series of a TKA implanted with a balanced gap technique (433 (77.7%) fixed, 124 (22.3%) mobile (anterior-posterior gliding (7-9 mm) and rotational (15°) degrees of freedom) inserts) were included for survival analysis (Kaplan-Meier, by insert type). At the 12-year follow-up (FU) examination of 189 cases, range of motion, knee society score (KSS), numeric rating scale (NRS) for pain and satisfaction were determined and radiographs were evaluated by median tests, by insert type. Of 521 cases available for analysis, 28 (5.4%; 11 fixed, 17 mobile bearing) were revised. Mean cumulative survival after 12.4 years was 97.0% (95% CI 94.7-98.4) for fixed bearings and 85.4% (95% CI 77.5-90.7) after 12.2 years for mobile bearings, p bearings. This study showed a superior survival for fixed bearing compared with mobile bearing in a CR TKA using a ligament-balanced technique after more than 12 years. Clinical outcomes are excellent to good after long-term follow-up, and similar for fixed and mobile bearing. Therapeutic studies-retrospective cohort study, Level III.

  10. Estimation of the effect of food irradiation on total dietary vitamin availability as compared with dietary allowances: study for Argentina

    International Nuclear Information System (INIS)

    Narvaiz, P.; Ladomery, L.G.

    1998-01-01

    The purpose of this work was to evaluate whether irradiation treatment of all foods, for which this treatment is of recognised technological usefulness, would have any detrimental effect on total dietary vitamin availability for consumption by the Argentinian population. Per capita availability of foods produced in or imported into Argentina that could be usefully irradiated and which are usually consumed in the country was recorded from FAO food balance sheets. The vitamin content of the foods and the vitamin losses occurring under good irradiation practices were gathered from the literature. The nutritional impact of vitamin losses due to irradiation was estimated by comparing results to the Recommended Dietary Allowances of the US National Research Council. The vitamins studied were: A, D, E, K, ascorbic acid, thiamine, riboflavin, niacin, pyridoxine, biotin, cyanocobalamin, folacin and pantothenic acid. Results showed that, even if irradiation was applied to every food which could be usefully treated, vitamin availabilities would exceed 100% of the respective RDA and so no adverse nutritional impact would be expected, except for folacin and vitamin D. However, typical availabilities of folate and vitamin D are less than the RDA. Synthesis of vitamin D in the skin from 7-dehydrocholesterol would suggest no nutritional problem. Available data on folic acid losses due to food irradiation are incomplete and suggest the need for further experimental research

  11. Comparing damage on retrieved total elbow replacement bushings with lab worn specimens subjected to varied loading conditions.

    Science.gov (United States)

    Willing, Ryan

    2018-01-09

    Complication rates following total elbow replacement (TER) with conventional implants are relatively high due to mechanical failure involving the UHMWPE bushings. Unfortunately, there are no standardized pre-clinical durability testing protocols for assessing the durability of TER components. This study examines the damage observed on retrieved humeral bushings, and then uses in vitro durability testing with two different loading protocols to compare resulting damage. Damage on 25 pairs of retrieved humeral bushings was characterized using micro-computed tomographic imaging techniques. The damage was compared with that of in vitro test specimens which were subjected to 200 K cycles of either high joint reaction force (high JRF) or high varus moment (high VM) loading. Material removal (mass loss) from bushing components was measured using gravimetric techniques. Thinning was less for retrieved bushings which were still assembled in their humeral component, versus bushings which were loose (0.3 ± 0.3 mm vs. 0.6 ± 0.3 mm, p = 0.02). Comparing in vitro test specimens, thinning due to high VM loading was 0.9 ± 0.3 mm, versus 0.2 ± 0.0 mm for high JRF loading (p = 0.08); however, the actual material removal rates from the humeral bushings were not different between the two protocols (48 ± 5 mm 3 /Mc vs. 43 ± 2 mm 3 /Mc, p = 1). Neither loading protocol could produce damage patterns fully representative of the spectrum of damage patterns observed on clinical retrievals. Pre-clinical testing should employ multiple loading protocols to characterize implant performance under a broader spectrum of usage. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. MR measures of renal perfusion, oxygen bioavailability and total renal blood flow in a porcine model: noninvasive regional assessment of renal function.

    Science.gov (United States)

    Wentland, Andrew L; Artz, Nathan S; Fain, Sean B; Grist, Thomas M; Djamali, Arjang; Sadowski, Elizabeth A

    2012-01-01

    Magnetic resonance imaging (MRI) may be a useful adjunct to current methods of evaluating renal function. MRI is a noninvasive imaging modality that has the ability to evaluate the kidneys regionally, which is lacking in current clinical methods. Other investigators have evaluated renal function with MRI-based measurements, such as with techniques to measure cortical and medullary perfusion, oxygen bioavailability and total renal blood flow (TRBF). However, use of all three techniques simultaneously, and therefore the relationships between these MRI-derived functional parameters, have not been reported previously. To evaluate the ability of these MRI techniques to track changes in renal function, we scanned 11 swine during a state of hyperperfusion with acetylcholine and a saline bolus and subsequently scanned during a state of hypoperfusion with the prolonged use of isoflurane anesthesia. For each time point, measurements of perfusion, oxygen bioavailability and TRBF were acquired. Measurements of perfusion and oxygen bioavailability were compared with measurements of TRBF for all swine across all time points. Cortical perfusion, cortical oxygen bioavailability, medullary oxygen bioavailability and TRBF significantly increased with the acetylcholine challenge. Cortical perfusion, medullary perfusion, cortical oxygen bioavailability and TRBF significantly decreased during isoflurane anesthesia. Cortical perfusion (Spearman's correlation coefficient = 0.68; P renal function. Maintenance of the medullary oxygen bioavailability in low blood flow states may reflect the autoregulation particular to this region of the kidney. The ability to non-invasively measure all three parameters of kidney function in a single MRI examination and to evaluate the relationships between these functional parameters is potentially useful for evaluating the state of the human kidneys in situ in future studies.

  13. Verification of a computational cardiovascular system model comparing the hemodynamics of a continuous flow to a synchronous valveless pulsatile flow left ventricular assist device.

    Science.gov (United States)

    Gohean, Jeffrey R; George, Mitchell J; Pate, Thomas D; Kurusz, Mark; Longoria, Raul G; Smalling, Richard W

    2013-01-01

    The purpose of this investigation is to use a computational model to compare a synchronized valveless pulsatile left ventricular assist device with continuous flow left ventricular assist devices at the same level of device flow, and to verify the model with in vivo porcine data. A dynamic system model of the human cardiovascular system was developed to simulate the support of a healthy or failing native heart from a continuous flow left ventricular assist device or a synchronous pulsatile valveless dual-piston positive displacement pump. These results were compared with measurements made during in vivo porcine experiments. Results from the simulation model and from the in vivo counterpart show that the pulsatile pump provides higher cardiac output, left ventricular unloading, cardiac pulsatility, and aortic valve flow as compared with the continuous flow model at the same level of support. The dynamic system model developed for this investigation can effectively simulate human cardiovascular support by a synchronous pulsatile or continuous flow ventricular assist device.

  14. Cutaneous blood flow. A comparative study between the thermal recovery method and the radioxenon clearance method

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, C M; Ferreira, J M; Fernandes, F V

    1975-01-01

    Since 1968 a thermal recovery method to study the cutaneous circulation has been utilized in the detection of skin circulation changes caused by certain pharmacological agents or by some pathological conditions. This method is based in the determination of the thermal recuperation of a small area of the skin previously cooled. In this work, we want to present the results of a comparative analysis between the thermal recovery method and the clearance of the radioactive xenon injected intracutaneously. The study was performed in the distal extremity of the lower limbs in 16 normal subjects, 16 hyperthyroid patients with increased cutaneous temperature and 11 patients with presumably low cutaneous blood flow (3 patients with hypothyroidism and 8 with obstructive arteriosclerosis).

  15. Comparative analysis of turbulence models for flow simulation around a vertical axis wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Roy, S.; Saha, U.K. [Indian Institute of Technology Guwahati, Dept. of Mechanical Engineering, Guwahati (India)

    2012-07-01

    An unsteady computational investigation of the static torque characteristics of a drag based vertical axis wind turbine (VAWT) has been carried out using the finite volume based computational fluid dynamics (CFD) software package Fluent 6.3. A comparative study among the various turbulence models was conducted in order to predict the flow over the turbine at static condition and the results are validated with the available experimental results. CFD simulations were carried out at different turbine angular positions between 0 deg.-360 deg. in steps of 15 deg.. Results have shown that due to high static pressure on the returning blade of the turbine, the net static torque is negative at angular positions of 105 deg.-150 deg.. The realizable k-{epsilon} turbulent model has shown a better simulation capability over the other turbulent models for the analysis of static torque characteristics of the drag based VAWT. (Author)

  16. Ultratrace element contents in rat tissues: Comparative analysis of serum and hair as indicative matrices of the total body burden

    Directory of Open Access Journals (Sweden)

    Skalny Anatoly V.

    2016-01-01

    Full Text Available The aim of this study was to investigate the distribution of ultratrace elements in rat tissues and to perform a comparative analysis of hair and serum as potential bioindicators of the total ultratrace element content. Thirty-six male Wistar rats were fed a standard chow containing 0.006±0.000, 0.001±0.000, 0.017±0.002, 0.382±0.031, 0.168±0.014, 3.211±0.134, 0.095±0.006, 0.000±0.000, 6.675±0.336, 15.327±0.564, 0.002±0.000, and 1.185±0.202 μg/g of silver (Ag, gold (Au, cesium (Cs, gallium (Ga, germanium (Ge, lanthanum (La, niobium (Nb, platinum (Pt, rubidium (Rb, titanium (Ti, thallium (Tland zirconium (Zr, respectively, from weaning to 3 months old. The ultratrace element content in the liver, kidney, muscle, heart, serum and hair was assessed using inductively coupled plasma mass spectrometry. The obtained data indicate that the highest concentrations of most of the studied elements (Ti, Zr, Ge, Nb, tungsten (W, La, uranium (U, Ag, Au, Pt are in hair, whereas the lowest were observed in the serum. Statistical analysis revealed a significant association between concentrations in the hair and other tissues for Cs, Ti, Nb, Tl, La, U and Au. At the same time, serum Cs, Rb, Ti, Ge, Nb, W, Ga, Tl and La concentrations significantly correlated with the tissue content of the respective ultratrace elements. It can be concluded that hair may be used as a potential bioindicator for certain ultratrace element content in the mammalian organism.

  17. Axial Dispersion Model for Solid Flow in Liquid Suspension in System of Two Mixers in Total Recycle

    Czech Academy of Sciences Publication Activity Database

    Čermáková, Jiřina; Scargiali, F.; Siyakatshana, N.; Kudrna, V.; Brucato, A.; Machoň, V.

    2006-01-01

    Roč. 117, č. 2 (2006), s. 101-107 ISSN 1385-8947 R&D Projects: GA AV ČR(CZ) IAA4072402 Institutional research plan: CEZ:AV0Z40720504 Keywords : residence time distribution * dispersion model * flow mixer Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.594, year: 2006

  18. COMPARATIVE EFFICIENCIES STUDY OF SLOT MODEL AND MOUSE MODEL IN PRESSURISED PIPE FLOW

    Directory of Open Access Journals (Sweden)

    Saroj K. Pandit

    2014-01-01

    Full Text Available The flow in sewers is unsteady and variable between free-surfac e to full pipe pressurized flow. Sewers are designed on the basis of free surf ace flow (gravity flow however they may carry pressurized flow. Preissmann Slot concep t is widely used numerical approach in unsteady free surface-pressurized flow as it provides the advantage of using free surface flow as a single type flow. Slo t concept uses the Saint- Venant’s equations as a basic equation for one-dimensional unst eady free surface flow. This paper includes two different numerical models using Saint Venant’s equations. The Saint Venant’s e quations of continuity and momen tum are solved by the Method of Characteristics and presented in forms for direct substitution into FORTRAN programming for numerical analysis in the first model. The MOUSE model carries out computation of unsteady flows which is founde d on an implicit, finite difference numerical solut ion of the basic one dimension al Saint Venant’s equations of free surface flow. The simulation results are comp ared to analyze the nature and degree of errors for further improvement.

  19. Modeling Mixed Bicycle Traffic Flow: A Comparative Study on the Cellular Automata Approach

    Directory of Open Access Journals (Sweden)

    Dan Zhou

    2015-01-01

    Full Text Available Simulation, as a powerful tool for evaluating transportation systems, has been widely used in transportation planning, management, and operations. Most of the simulation models are focused on motorized vehicles, and the modeling of nonmotorized vehicles is ignored. The cellular automata (CA model is a very important simulation approach and is widely used for motorized vehicle traffic. The Nagel-Schreckenberg (NS CA model and the multivalue CA (M-CA model are two categories of CA model that have been used in previous studies on bicycle traffic flow. This paper improves on these two CA models and also compares their characteristics. It introduces a two-lane NS CA model and M-CA model for both regular bicycles (RBs and electric bicycles (EBs. In the research for this paper, many cases, featuring different values for the slowing down probability, lane-changing probability, and proportion of EBs, were simulated, while the fundamental diagrams and capacities of the proposed models were analyzed and compared between the two models. Field data were collected for the evaluation of the two models. The results show that the M-CA model exhibits more stable performance than the two-lane NS model and provides results that are closer to real bicycle traffic.

  20. Comparative calculations on selected two-phase flow phenomena using major PWR system codes

    International Nuclear Information System (INIS)

    1990-01-01

    In 1988 a comparative study on important features and models in six major best estimate thermal hydraulic codes for PWR systems was implemented (Comparison of thermal hydraulic safety codes for PWR Graham, Trotman, London, EUR 11522). It was a limitation of that study that the source codes themselves were not available but the comparison had to be based on the available documentation. In the present study, the source codes were available and the capability of four system codes to predict complex two-phase flow phenomena has been assessed. Two areas of investigation were selected: (a) pressurized spray phenomena; (b) boil-up phenomena in rod bundles. As regards the first area, experimental data obtained in 1972 on the Neptunus Facility (Delft University of Technology) were compared with the results of the calculations using Athlet, Cathare, Relap 5 and TRAC-PT1 and, concerning the second area, the results of two experimental facilities obtained in 1980 and 1985 on Thetis (UKEA) and Pericles (CEA-Grenoble) were considered

  1. A comparative analysis of hazard models for predicting debris flows in Madison County, VA

    Science.gov (United States)

    Morrissey, Meghan M.; Wieczorek, Gerald F.; Morgan, Benjamin A.

    2001-01-01

    During the rainstorm of June 27, 1995, roughly 330-750 mm of rain fell within a sixteen-hour period, initiating floods and over 600 debris flows in a small area (130 km2) of Madison County, Virginia. Field studies showed that the majority (70%) of these debris flows initiated with a thickness of 0.5 to 3.0 m in colluvium on slopes from 17 o to 41 o (Wieczorek et al., 2000). This paper evaluated and compared the approaches of SINMAP, LISA, and Iverson's (2000) transient response model for slope stability analysis by applying each model to the landslide data from Madison County. Of these three stability models, only Iverson's transient response model evaluated stability conditions as a function of time and depth. Iverson?s model would be the preferred method of the three models to evaluate landslide hazards on a regional scale in areas prone to rain-induced landslides as it considers both the transient and spatial response of pore pressure in its calculation of slope stability. The stability calculation used in SINMAP and LISA is similar and utilizes probability distribution functions for certain parameters. Unlike SINMAP that only considers soil cohesion, internal friction angle and rainfall-rate distributions, LISA allows the use of distributed data for all parameters, so it is the preferred model to evaluate slope stability over SINMAP. Results from all three models suggested similar soil and hydrologic properties for triggering the landslides that occurred during the 1995 storm in Madison County, Virginia. The colluvium probably had cohesion of less than 2KPa. The root-soil system is above the failure plane and consequently root strength and tree surcharge had negligible effect on slope stability. The result that the final location of the water table was near the ground surface is supported by the water budget analysis of the rainstorm conducted by Smith et al. (1996).

  2. Power Doppler flow mapping and four-dimensional ultrasound for evaluating tubal patency compared with laparoscopy.

    Science.gov (United States)

    Soliman, Amr A; Shaalan, Waleed; Abdel-Dayem, Tamer; Awad, Elsayed Elbadawy; Elkassar, Yasser; Lüdders, Dörte; Malik, Eduard; Sallam, Hassan N

    2015-12-01

    To study the accuracy of four-dimensional (4D) ultrasound and power Doppler flow mapping in detecting tubal patency in women with sub-/infertility, and compare it with laparoscopy and chromopertubation. A prospective study. The study was performed in the outpatient clinic and infertility unit of a university hospital. The sonographic team and laparoscopic team were blinded to the results of each other. Women aged younger than 43 years seeking medical advice due to primary or secondary infertility and who planned to have a diagnostic laparoscopy performed, were recruited to the study after signing an informed consent. All of the recruited patients had power Doppler flow mapping and 4D hysterosalpingo-sonography by injecting sterile saline into the fallopian tubes 1 day before surgery. Registering Doppler signals, while using power Doppler, both at the tubal ostia and fimbrial end and the ability to demonstrate the course of the tube especially the isthmus and fimbrial end, while using 4D mode, was considered a patent tube. Out of 50 recruited patients, 33 women had bilateral patent tubes and five had unilateral patent tubes as shown by chromopertubation during diagnostic laparoscopy. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for two-dimensional power Doppler hysterosalpingography were 94.4%, 100%, 100%, 89.2%, and 96.2%, respectively and for 4D ultrasound were 70.4%, 100%, 100%, 70.4%, and 82.6%, respectively. Four-dimensional saline hysterosalpingography has acceptable accuracy in detecting tubal patency, but is surpassed by power Doppler saline hysterosalpingography. Power Doppler saline hysterosalpingography could be incorporated into the routine sub-/infertility workup. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Comparing characteristics and clinical and echocardiographic outcomes in low-flow vs normal-flow severe aortic stenosis with preserved ejection fraction in an Asian population.

    Science.gov (United States)

    Ngiam, Jinghao Nicholas; Tan, Benjamin Yong-Qiang; Sia, Ching-Hui; Lee, Glenn K M; Kong, William K F; Chan, Yiong-Huak; Poh, Kian-Keong

    2017-05-01

    In severe aortic stenosis (AS), deterioration of left ventricular ejection fraction (LVEF) to 50%) and with paired echocardiography were studied. Univariate and multivariate analyses identified factors associated with LVEF deterioration. Clinical outcomes were determined on follow-up for more than 5 years. Significant LVEF deterioration (to <50%) was seen in 18% of low-flow (initial LVEF 63±8% to 32±9%) and 18% of normal-flow AS (61±7% to 31±12%). Independent factors in low-flow AS were hypertension (OR: 30.7, 95% CI: 2.0-467.6, P=.014) and higher end-systolic wall stress (OR: 1.086, 95% CI: 1.022-1.153, P=.008), compared to normal-flow, which were hypertension (OR: 15.9, 95% CI: 3.1-81.9, P=.001), higher septal E/E' ratio (OR: 1.16, 95% CI: 1.01-1.35, P=.043), lower septal S' velocity (OR: 0.204, 95% CI: 0.061-0.682, P=.010), and higher end-systolic wall stress (OR: 1.051, 95% CI: 1.001-1.104, P=.047). Overall, a third of the cohort experienced MACE, regardless of flow (log-rank 0.048, P=.827). However, aortic valve replacement (AVR) rates were lower in low-flow AS (20% vs 43%, P=.005). Low-flow AS despite normal LVEF appears similar to normal-flow in terms of LVEF deterioration and clinical outcomes in our Asian population. AVR rate was lower even though low-flow may not reflect less severe disease. © 2017, Wiley Periodicals, Inc.

  4. Late group-based rehabilitation has no advantages compared with supervised home-exercises after total knee arthroplasty

    DEFF Research Database (Denmark)

    Madsen, Majbritt; Larsen, Kristian; Madsen, Inger Kirkegård

    2013-01-01

    This study aimed to test whether group-based rehabilitation focusing on strength training, education and self-management is more effective than individual, supervised home-training after fast-track total knee arthroplasty (TKA).......This study aimed to test whether group-based rehabilitation focusing on strength training, education and self-management is more effective than individual, supervised home-training after fast-track total knee arthroplasty (TKA)....

  5. The CI-Flow Project: A System for Total Water Level Prediction from the Summit to the Sea

    Science.gov (United States)

    2011-11-01

    round and may be applied to all types of coastal storms , including intense cool- season extratropical cyclones (i.e., nor’easters). In addition...associated with waves, tides, storm surge, rivers, and rainfall, including interactions at the tidal/surge interface Within this project, Cl-FLOW addresses...presented for Hurricane Isabel (2003), Hurricane Earl (20I0), and Tropical Storm Nicole (2010) for the Tar -Pamlico and Neuse River basins of North

  6. A Comparative Study of Foreign Direct Investment Flow Using Diffusion Models

    Science.gov (United States)

    Li, Yiming; Chiang, Yi-Hui; Yu, Shao-Ming; Chiang, Su-Yun; Hung, C.-H.

    2007-12-01

    In this work, we apply an improvement dynamic model of the foreign direct investment (FDI) flow to analyze the evolution of FDI flow. In comparison with the fundamental growth model of FDI, the simulation result is further accurate if the asymmetric growth pattern and heterogeneity of the potential adopters are considered. According to the result, the internal influence dominates the growth of FDI flow from Taiwan to China during 2001-2006, taking the electronics industry for example.

  7. Embodied carbon dioxide flow in international trade: A comparative analysis based on China and Japan.

    Science.gov (United States)

    Long, Ruyin; Li, Jinqiu; Chen, Hong; Zhang, Linling; Li, Qianwen

    2018-03-01

    Carbon dioxide embodied flow in international trade has become an important factor in defining global carbon emission responsibility and climate policy. We conducted an empirical analysis for China and Japan for the years 2000-2014, using a multi-region input-output model and considering the rest of the world as a comparison group. We compared the two countries' direct and complete carbon dioxide emissions intensity and bilateral economic activities such as imports and exports, production and consumption to analyze the difference between China and Japan. The results showed that the intensities of carbon emissions in all sectors of China were higher than that in Japan and that China's annual production-based emissions were greater than consumption-based emissions, the opposite of these relationships in Japan. China was a typical net carbon export country, and carbon embodied in its imports and exports continued to increase throughout the study period. In contrast, Japan's volume and growth rate of embodied carbon emissions were far less than China's and Japan was a typical net carbon import country. Finally, the conclusions of this study support recommendations for the formulation of international carbon emission responsibility allocation, domestic abatement policy as well as China's trade policy. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. A CFD analysis of the actuator disc flow compared with momentum theory results

    Energy Technology Data Exchange (ETDEWEB)

    Aagaard Madsen, H. [Risoe National Laboratory, Roskilde (Denmark)

    1997-08-01

    The blade element momentum (BEM) model is still used in many aerodynamic and aeroelastic models for design and load calculations. This is due to its simplicity, robustness, computational speed and good accuracy for a wide range of applications. The question about accuracy is however closely connected to the airfoil section data and therefore correlation/lack of correlation with experimental results can both be due to the specific input data used and due to the induced velocity field predicted by the BEM method. It is also well-known that the BEM method for some applications is used under operational conditions that violates the assumptions made for the development of the model, e.g. operation in yaw and operation at high loading. The main objective with the present study is to investigate this part of the BEM method (the momentum strip theory MST) on which the determination of the induced velocities is based. This is done by comparing the results of the MST model with velocities predicted on basis of the Navier Stokes equations for the flow through an actuator disc. (au)

  9. Numerical modeling of carrier gas flow in atomic layer deposition vacuum reactor: A comparative study of lattice Boltzmann models

    International Nuclear Information System (INIS)

    Pan, Dongqing; Chien Jen, Tien; Li, Tao; Yuan, Chris

    2014-01-01

    This paper characterizes the carrier gas flow in the atomic layer deposition (ALD) vacuum reactor by introducing Lattice Boltzmann Method (LBM) to the ALD simulation through a comparative study of two LBM models. Numerical models of gas flow are constructed and implemented in two-dimensional geometry based on lattice Bhatnagar–Gross–Krook (LBGK)-D2Q9 model and two-relaxation-time (TRT) model. Both incompressible and compressible scenarios are simulated and the two models are compared in the aspects of flow features, stability, and efficiency. Our simulation outcome reveals that, for our specific ALD vacuum reactor, TRT model generates better steady laminar flow features all over the domain with better stability and reliability than LBGK-D2Q9 model especially when considering the compressible effects of the gas flow. The LBM-TRT is verified indirectly by comparing the numerical result with conventional continuum-based computational fluid dynamics solvers, and it shows very good agreement with these conventional methods. The velocity field of carrier gas flow through ALD vacuum reactor was characterized by LBM-TRT model finally. The flow in ALD is in a laminar steady state with velocity concentrated at the corners and around the wafer. The effects of flow fields on precursor distributions, surface absorptions, and surface reactions are discussed in detail. Steady and evenly distributed velocity field contribute to higher precursor concentration near the wafer and relatively lower particle velocities help to achieve better surface adsorption and deposition. The ALD reactor geometry needs to be considered carefully if a steady and laminar flow field around the wafer and better surface deposition are desired

  10. Numerical modeling of carrier gas flow in atomic layer deposition vacuum reactor: A comparative study of lattice Boltzmann models

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Dongqing; Chien Jen, Tien [Department of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, Wisconsin 53201 (United States); Li, Tao [School of Mechanical Engineering, Dalian University of Technology, Dalian 116024 (China); Yuan, Chris, E-mail: cyuan@uwm.edu [Department of Mechanical Engineering, University of Wisconsin-Milwaukee, 3200 North Cramer Street, Milwaukee, Wisconsin 53211 (United States)

    2014-01-15

    This paper characterizes the carrier gas flow in the atomic layer deposition (ALD) vacuum reactor by introducing Lattice Boltzmann Method (LBM) to the ALD simulation through a comparative study of two LBM models. Numerical models of gas flow are constructed and implemented in two-dimensional geometry based on lattice Bhatnagar–Gross–Krook (LBGK)-D2Q9 model and two-relaxation-time (TRT) model. Both incompressible and compressible scenarios are simulated and the two models are compared in the aspects of flow features, stability, and efficiency. Our simulation outcome reveals that, for our specific ALD vacuum reactor, TRT model generates better steady laminar flow features all over the domain with better stability and reliability than LBGK-D2Q9 model especially when considering the compressible effects of the gas flow. The LBM-TRT is verified indirectly by comparing the numerical result with conventional continuum-based computational fluid dynamics solvers, and it shows very good agreement with these conventional methods. The velocity field of carrier gas flow through ALD vacuum reactor was characterized by LBM-TRT model finally. The flow in ALD is in a laminar steady state with velocity concentrated at the corners and around the wafer. The effects of flow fields on precursor distributions, surface absorptions, and surface reactions are discussed in detail. Steady and evenly distributed velocity field contribute to higher precursor concentration near the wafer and relatively lower particle velocities help to achieve better surface adsorption and deposition. The ALD reactor geometry needs to be considered carefully if a steady and laminar flow field around the wafer and better surface deposition are desired.

  11. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  12. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with "1"3N-Ammonia PET myocardial blood flow quantitation

    International Nuclear Information System (INIS)

    Hsu, Bailing; Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng; Chen, Lung-Ching; Chen, Yen-Kung; Hung, Guang-Uei; Wu, Tao-Cheng

    2017-01-01

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of "9"9"mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with "1"3N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R"2: MBF = 0.92, MFR = 0.78; regional R"2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected. (orig.)

  13. Autologous re-transfusion drain compared with no drain in total knee arthroplasty : a randomised controlled trial

    NARCIS (Netherlands)

    Horstmann, Wieger; Kuipers, Bart; Ohanis, David; Slappendel, Robert; Kollen, Boudewijn; Verheyen, Cees

    Background. Post-operative anaemia following total knee arthroplasty is reported to impede functional mobility in the early period following surgery, whereas allogeneic blood transfusions, used to correct low post-operative haemoglobin levels, have concomitant disadvantages. The use of a

  14. Comparative seric TGF(β1, β2) levels and platelets count response in total body irradiated baboons

    International Nuclear Information System (INIS)

    Mestries, J.C.; Veyret, J.; Agay, D.; Van Uye, A.; Caterini, R.; Herodin, F.; Mathieu, J.; Chancerelle, Y.

    1994-01-01

    Total body irradiation associated or not with r-hIL-6 treatment a relation between TGF-β1 and TGF-β2 blood levels and platelets count. During radio-induced thrombocytopenia, by decreasing its ability to inhibit proliferation of stem cells and megakaryocytopoiesis, the TGF-β falling induced a favorable condition for hematopoietic recovery. (author)

  15. Comparative methane estimation from cattle based on total CO2 production using different techniques

    DEFF Research Database (Denmark)

    Haque, Md N.; Hansen, Hanne H.; Storm, Ida M.L.D.

    2017-01-01

    cages for 3 periods. Each period consisted of 2 weeks of adaptation followed by 1 week of measurement with the CO2R and CO2T. The average body weight of the heifer was 226 ± 11 kg (means ± SD). They were fed a total mixed ration, twice daily, with 1 of 3 supplements: wheat (W), molasses (M), or molasses...

  16. A comparative study on the flow over an airfoil using transitional turbulence models

    DEFF Research Database (Denmark)

    Lin, Mou; Sarlak Chivaee, Hamid

    2016-01-01

    This work addresses the simulation of the flow over NREL S826 airfoil under a relatively low Reynolds number (Re = 1 × 105 ) using the CFD solvers OpenFoam and ANSYS Fluent. The flow is simulated using two different transition models, γ − Reθ and k − kL − ω model, and the results are examined...

  17. Liquidity Analysis Using Cash Flow Ratios as Compared to Traditional Ratios in the Pharmaceutical Sector in Jordan

    OpenAIRE

    Sulayman H. Atieh

    2014-01-01

    The purpose of this study is to examine the liquidity position of the Jordanian pharmaceutical sector using the traditional ratios as compared to the more recently developed cash flow ratios. The research involved the comparison between traditional ratios and cash flow ratios of the big seven companies of the pharmaceutical industry in Jordan over six years period (2007¨C2012). The companies were all from the same sector, and the data was obtained from the annual reports of these companies. T...

  18. Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

    Science.gov (United States)

    Yambe, T; Hashimoto, H; Kobayashi, S; Sonobe, T; Naganuma, S; Nanka, S S; Matsuki, H; Yoshizawa, M; Tabayashi, K; Takayasu, H; Takeda, H; Nitta, S

    1997-01-01

    We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

  19. Comparative Analysis of ?-Oryzanol, ?-Glucan, Total Phenolic Content and Antioxidant Activity in Fermented Rice Bran of Different Varieties

    OpenAIRE

    Jung, Tae-Dong; Shin, Gi-Hae; Kim, Jae-Min; Choi, Sun-Il; Lee, Jin-Ha; Lee, Sang Jong; Park, Seon Ju; Woo, Koan Sik; Oh, Sea Kwan; Lee, Ok-Hawn

    2017-01-01

    Rice bran, a by-product derived from processing rice, is a rich source of bioactive compounds. Recent studies have suggested that the fermentation can improve their biological activities. This study aimed to determined the level of γ-oryzanol, β-glucan and total phenol contents of fermented rice bran from 21 Korean varieties, as well as to evaluate their antioxidant activities. We also assessed the validation of the analytical method for determining γ-oryzanol content in fermented rice brans....

  20. A comparative simulation of feed and bleed operation during the total loss of feedwater event by RELAP5/MOD3 and CEFLASH-4AS/REM computer codes

    International Nuclear Information System (INIS)

    Kwon, Y.M.; Ro, T.S.; Song, J.H.

    1995-01-01

    The Ulchin 3 and 4 nuclear power plants, which are two-loop 2,825 MW(thermal) pressurized water reactors designed by the Korea Atomic Energy Research Institute, adopted a safety depressurization system (SDS) to mitigate the beyond-design-basis event of a total loss of feedwater (TLOFW). A comparative simulation by the CEFLASH-4AS/REM and RELAP5/MOD3 computer codes for the TLOFW event without operator recovery and the TLOFW event with feed and bleed (F and B) operation is performed for Ulchin 3 and 4. In the analyses, the SDS bleed paths are modeled by orifices located on the top of the pressurizer, where the analytical area of the bleed path is based on the Ulchin 3 and 4 SDS design flow capacity. An additional case, where the SDS piping and valves are modeled explicitly, is considered for the RELAP5 analysis. The predictions by the CEFLASH-4AS/REM of the transient two-phase system behavior show good qualitative and quantitative agreement with those by the RELAP5 simulation. The RELAP5 case with explicit piping results in less repressurization and lower reactor coolant system pressure than that of the case without explicit SDS modeling. However, the two cases of RELAP5 analyses result in essentially the same transient scenarios for TLOFW with F and B operation. The results of the simulation demonstrate the validity of the Ulchin 3 and 4 design approach, which employs CEFLASH-4AS/REM computer code and SDS bleed paths modeled by orifices located on the top of the pressurizer. The results also indicate that the decay heat removal and core inventory makeup function can be successfully accomplished by F and B operation by using the SDS for Ulchin 3 and 4

  1. Comparative study on flow rate measurement by nuclear and conventional methods in selected rivers at Ulu Langat district, Selangor

    Energy Technology Data Exchange (ETDEWEB)

    Wan Mohamad Tahir, Wan Zakaria; Mohamad, Daud; Hamzah, Abdul Razak; Yusuf, Johari Mohamad; Aziz Wan Mohamad, Wan Abdul

    1986-06-01

    A radiotracer technique using Tc-99 to measure flows of small rivers was introduced in Malaysia. Three rivers in the Ulu Langat District were selected for a comparative study on flow rate determination by conventional and radioisotope methods. Radioisotopic approach, comprising injection procedures, calibration, mixing length and safety aspects are discussed. The results measured by radioisotope method are compared to the Drainage and Irrigation Department's (DID's) discharge curves data collected from 1980 to 1982 which is calibrated using a current meter. The results are comparable and fall within the range obtained by conventional method. Related to this study, a comprehensive work on stream gauging of moderate and high flow rates using both methods is proposed to be carried out directly.

  2. Multiple breath washout with a sidestream ultrasonic flow sensor and mass spectrometry: a comparative study.

    Science.gov (United States)

    Fuchs, Susanne I; Buess, Christian; Lum, Sooky; Kozlowska, Wanda; Stocks, Janet; Gappa, Monika

    2006-12-01

    Over recent years, there has been renewed interest in the multiple breath wash-out (MBW) technique for assessing ventilation inhomogeneity (VI) as a measure of early lung disease in children. While currently considered the gold standard, use of mass spectrometry (MS) to measure MBW is not commercially available, thereby limiting widespread application of this technique. A mainstream ultrasonic flow sensor was marketed for MBW a few years ago, but its use was limited to infants. We have recently undertaken intensive modifications of both hardware and software for the ultrasonic system to extend its use for older children. The aim of the current in vivo study was to compare simultaneous measurements of end-tidal tracer gas concentrations and lung clearance index (LCI) from this modified ultrasonic device with those from a mass spectrometer. Paired measurements of three MBW, using 4% sulfur hexafluoride (SF(6)) as the tracer gas and the two systems in series, were obtained in nine healthy adult volunteers. End-tidal tracer gas concentrations (n = 675 paired values) demonstrated close agreement (95% CI of difference -0.23; -0.17%, r(2) = 1). FRC was slightly higher from the MS (95%CI 0.08;0.17 L), but there was no difference in LCI (95%CI -0.10; 0.3). We conclude, that this ultrasonic prototype system measures end-tidal tracer gas concentration accurately and may therefore be a valid tool for MBW beyond early childhood. This prototype system could be the basis for a commercial device allowing more widespread application of MBW in the near future.

  3. Stochastic or statistic? Comparing flow duration curve models in ungauged basins and changing climates

    Science.gov (United States)

    Müller, M. F.; Thompson, S. E.

    2015-09-01

    The prediction of flow duration curves (FDCs) in ungauged basins remains an important task for hydrologists given the practical relevance of FDCs for water management and infrastructure design. Predicting FDCs in ungauged basins typically requires spatial interpolation of statistical or model parameters. This task is complicated if climate becomes non-stationary, as the prediction challenge now also requires extrapolation through time. In this context, process-based models for FDCs that mechanistically link the streamflow distribution to climate and landscape factors may have an advantage over purely statistical methods to predict FDCs. This study compares a stochastic (process-based) and statistical method for FDC prediction in both stationary and non-stationary contexts, using Nepal as a case study. Under contemporary conditions, both models perform well in predicting FDCs, with Nash-Sutcliffe coefficients above 0.80 in 75 % of the tested catchments. The main drives of uncertainty differ between the models: parameter interpolation was the main source of error for the statistical model, while violations of the assumptions of the process-based model represented the main source of its error. The process-based approach performed better than the statistical approach in numerical simulations with non-stationary climate drivers. The predictions of the statistical method under non-stationary rainfall conditions were poor if (i) local runoff coefficients were not accurately determined from the gauge network, or (ii) streamflow variability was strongly affected by changes in rainfall. A Monte Carlo analysis shows that the streamflow regimes in catchments characterized by a strong wet-season runoff and a rapid, strongly non-linear hydrologic response are particularly sensitive to changes in rainfall statistics. In these cases, process-based prediction approaches are strongly favored over statistical models.

  4. A comparative study of roll compaction of free-flowing and cohesive pharmaceutical powders.

    Science.gov (United States)

    Yu, Shen; Gururajan, Bindhu; Reynolds, Gavin; Roberts, Ron; Adams, Michael J; Wu, Chuan-Yu

    2012-05-30

    Roll compaction is widely adopted as a dry granulation method in the pharmaceutical industry. The roll compaction behaviour of feed powders is primarily governed by two parameters: the maximum pressure and the nip angle. Although the maximum pressure can be measured directly using pressure sensors fitted in the rolls, it is not a trivial task to determine the nip angle, which is a measure of the size of the compaction zone and hence the degree of compression. Thus a robust approach based upon the calculation of the pressure gradient, which can be obtained directly from experiments using an instrumented roll compactor, was developed. It has been shown that the resulting nip angles are comparable to those obtained using the methods reported in literature. Nevertheless, the proposed approach has distinctive advantages including (1) it is based on the intrinsic features of slip and no-slip interactions between the powder and roll surface and (2) it is not necessary to carry out wall friction measurements that involve plates that may not be representative of the roll compactor in terms of the surface topography and surface energy. The method was evaluated by investigating the effect of roll speed for two pharmaceutical excipients with distinctive material properties: microcrystalline cellulose (MCC) and di-calcium phosphate dihydrate (DCPD). It was found that the maximum pressure and nip angle for DCPD, which is a cohesive powder, decrease sharply with increasing roll speed whereas they are essentially independent of roll speed for MCC, which is an easy flowing powder. The roll compaction behaviour of MCC-DCPD mixtures with various compositions was also investigated in order to evaluate the effect of flowability. It was found that the nip angle and maximum pressure generally increased with improved flowability of the feed powders. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Positron emission tomography detects greater blood flow and less blood flow heterogeneity in the exercising skeletal muscles of old compared with young men during fatiguing contractions

    Science.gov (United States)

    Rudroff, Thorsten; Weissman, Jessica A; Bucci, Marco; Seppänen, Marko; Kaskinoro, Kimmo; Heinonen, Ilkka; Kalliokoski, Kari K

    2014-01-01

    The purpose of this study was to investigate blood flow and its heterogeneity within and among the knee muscles in five young (26 ± 6 years) and five old (77 ± 6 years) healthy men with similar levels of physical activity while they performed two types of submaximal fatiguing isometric contraction that required either force or position control. Positron emission tomography (PET) and [15O]-H2O were used to determine blood flow at 2 min (beginning) and 12 min (end) after the start of the tasks. Young and old men had similar maximal forces and endurance times for the fatiguing tasks. Although muscle volumes were lower in the older subjects, total muscle blood flow was similar in both groups (young men: 25.8 ± 12.6 ml min−1; old men: 25.1 ± 15.4 ml min−1; age main effect, P = 0.77) as blood flow per unit mass of muscle in the exercising knee extensors was greater in the older (12.5 ± 6.2 ml min−1 (100 g)−1) than the younger (8.6 ± 3.6 ml min−1 (100 g)−1) men (age main effect, P = 0.001). Further, blood flow heterogeneity in the exercising knee extensors was significantly lower in the older (56 ± 27%) than the younger (67 ± 34%) men. Together, these data show that although skeletal muscles are smaller in older subjects, based on the intact neural drive to the muscle and the greater, less heterogeneous blood flow per gram of muscle, old fit muscle achieves adequate exercise hyperaemia. Key points The results of previous studies that attempted to demonstrate the effects of ageing on skeletal muscle blood flow are controversial because these studies used indirect assessments of skeletal muscle blood flow obtained via whole limb blood flow measurements that provide no information on the distribution of blood flow within particular muscles. We used positron emission tomography to measure blood flow per gram of muscle in old and young men with similar levels of physical activity

  6. Comparative study of turbulence model performance for axisymmetric sudden expansion flow

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo; Yoon, Juhyeon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In this study, the performance of turbulence models in predicting the turbulent flow in an axisymmetric sudden expansion with an expansion ratio of 4 is assessed for a Reynolds number of 5.6 Χ 10{sup 4}. The comparisons show that the standard k-ε and RSM models provide the best agreement with the experimental data, whereas the standard k-ω model gives poor predictions. Owing to its computational efficiency, the Reynolds Averaged Navier-Stokes (RANS) approach has been widely used for the prediction of turbulent flows and associated pressure losses in a variety of internal flow systems such as a diffuser, orifice, converging nozzle, and pipes with sudden expansion. However, the lack of a general turbulence model often leads to limited applications of a RANS approach, i. e., the accuracy and validity of solutions obtained from RANS equations vary with the turbulence model, flow regime, near-wall treatment, and configuration of the problem. In light of the foregoing, a large amount of turbulence research has been conducted to assess the performance of existing turbulence models for different flow fields. In this paper, the turbulent flow in an axisymmetric sudden expansion is numerically investigated for a Reynolds number of 5.6 Χ 10{sup 4}, with the aim of examining the performance of several turbulence models.

  7. Comparative study of turbulence model performance for axisymmetric sudden expansion flow

    International Nuclear Information System (INIS)

    Bae, Youngmin; Kim, Young In; Kim, Keung Koo; Yoon, Juhyeon

    2013-01-01

    In this study, the performance of turbulence models in predicting the turbulent flow in an axisymmetric sudden expansion with an expansion ratio of 4 is assessed for a Reynolds number of 5.6 Χ 10 4 . The comparisons show that the standard k-ε and RSM models provide the best agreement with the experimental data, whereas the standard k-ω model gives poor predictions. Owing to its computational efficiency, the Reynolds Averaged Navier-Stokes (RANS) approach has been widely used for the prediction of turbulent flows and associated pressure losses in a variety of internal flow systems such as a diffuser, orifice, converging nozzle, and pipes with sudden expansion. However, the lack of a general turbulence model often leads to limited applications of a RANS approach, i. e., the accuracy and validity of solutions obtained from RANS equations vary with the turbulence model, flow regime, near-wall treatment, and configuration of the problem. In light of the foregoing, a large amount of turbulence research has been conducted to assess the performance of existing turbulence models for different flow fields. In this paper, the turbulent flow in an axisymmetric sudden expansion is numerically investigated for a Reynolds number of 5.6 Χ 10 4 , with the aim of examining the performance of several turbulence models

  8. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  9. Novel ex vivo culture method for human monocytes uses shear flow to prevent total loss of transendothelial diapedesis function.

    Science.gov (United States)

    Tsubota, Yoshiaki; Frey, Jeremy M; Raines, Elaine W

    2014-01-01

    Monocyte recruitment to inflammatory sites and their transendothelial migration into tissues are critical to homeostasis and pathogenesis of chronic inflammatory diseases. However, even short-term suspension culture of primary human monocytes leads to phenotypic changes. In this study, we characterize the functional effects of ex vivo monocyte culture on the steps involved in monocyte transendothelial migration. Our data demonstrate that monocyte diapedesis is impaired by as little as 4 h culture, and the locomotion step is subsequently compromised. After 16 h in culture, monocyte diapedesis is irreversibly reduced by ∼90%. However, maintenance of monocytes under conditions mimicking physiological flow (5-7.5 dyn/cm²) is sufficient to reduce diapedesis impairment significantly. Thus, through the application of shear during ex vivo culture of monocytes, our study establishes a novel protocol, allowing functional analyses of monocytes not currently possible under static culture conditions. These data further suggest that monocyte-based therapeutic applications may be measurably improved by alteration of ex vivo conditions before their use in patients.

  10. A π-Conjugation Extended Viologen as a Two-Electron Storage Anolyte for Total Organic Aqueous Redox Flow Batteries.

    Science.gov (United States)

    Luo, Jian; Hu, Bo; Debruler, Camden; Liu, Tianbiao Leo

    2018-01-02

    Extending the conjugation of viologen by a planar thiazolo[5,4-d]thiazole (TTz) framework and functionalizing the pyridinium with hydrophilic ammonium groups yielded a highly water-soluble π-conjugation extended viologen, 4,4'-(thiazolo[5,4-d]thiazole-2,5-diyl)bis(1-(3-(trimethylammonio)propyl)pyridin-1-ium) tetrachloride, [(NPr) 2 TTz]Cl 4  , as a novel two-electron storage anolyte for aqueous organic redox flow battery (AORFB) applications. Its physical and electrochemical properties were systematically investigated. Paired with 4-trimethylammonium-TEMPO (N Me -TEMPO) as catholyte, [(NPr) 2 TTz]Cl 4 enables a 1.44 V AORFB with a theoretical energy density of 53.7 Wh L -1 . A demonstrated [(NPr) 2 TTz]Cl 4 /N Me -TEMPO AORFB delivered an energy efficiency of 70 % and 99.97 % capacity retention per cycle. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. String-like lumen in below-the-knee chronic total occlusions on contrast-enhanced magnetic resonance angiography predicts intraluminal recanalization and better blood flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yue-Qi; Lu, Hai-Tao; Wei, Li-Ming; Cheng, Ying-Sheng; Wang, Jian-Bo; Zhao, Jun-Gong [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Department of Diagnostic and Interventional Radiology, Shanghai (China); Liu, Fang [Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, Department of Endocrinology, Shanghai (China)

    2017-07-15

    To determine whether string-like lumina (SLs) on contrast-enhanced magnetic resonance angiography (CE-MRA) predict better outcomes in diabetic patients with below-the-knee (BTK) chronic total occlusions (CTOs). This study involved 317 long-segment (>5 cm) BTK CTOs of 245 patients that were examined using CE-MRA and treated using endovascular angioplasty. An SL with a CTO was slowly filled with blood on conventional CE-MRA. Univariate and multivariate analyses were performed to identify predictors of procedural success, recanalisation method and immediate blood flow restoration. The target-lesion patency and limb-salvage rates were assessed. SL-positive CTOs (n = 60) achieved a higher technique success rate, preferred intraluminal angioplasty and better blood flow restoration than SL-negative CTOs (n = 257, P < 0.05). Multivariate analyses revealed that lesion length was the independent predictor of procedural success (P = 0.028). SL was a predictor of intraluminal angioplasty (P < 0.001) and good blood-flow restoration (P = 0.004). Kaplan-Meier analyses at 12 months revealed a higher target lesion patency rate (P = 0.04) and limb-salvage rate (P = 0.35) in SL-positive CTOs. In patients with BTK CTOs, SL predicted intraluminal angioplasty and good blood-flow restoration for BTK CTOs. (orig.)

  13. Numerical simulations of the internal flow pattern of a vortex pump compared to the Hamel-Oseen vortex

    International Nuclear Information System (INIS)

    Gerlach, Angela; Preuss, Enrico; Thamsen, Paul Uwe; Lykholt-Ustrup, Flemming

    2017-01-01

    We did a numerical study of the internal flow field of a vortex pump. Five operating points were considered and validated through a measured characteristic curve. The internal flow pattern of a vortex pump was analyzed and compared to the Hamel-Oseen vortex model. The calculated flow field was assessed with respect to the circumferential velocity, the vorticity and the axial velocity. Whereas the trajectories of the circumferential velocity were largely in line with the Hamel-Oseen vortex model, the opposite was true for vorticity. Only the vorticity at strong part load was in line with the predictions of the Hamel-Oseen vortex model. We therefore compared the circumferential velocity and vorticity for strong part load operation to the analytical predictions of the Hamel-Oseen vortex model. The simulated values were below the analytical values. The study therefore suggests that a vortex similar to the Hamel-Oseen vortex is only present at the strong part load operation

  14. Numerical simulations of the internal flow pattern of a vortex pump compared to the Hamel-Oseen vortex

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, Angela; Preuss, Enrico; Thamsen, Paul Uwe [Institute of Fluid System Dynamics, Technische Universitaet, Berlin (Germany); Lykholt-Ustrup, Flemming [Grundfos Holding A/S, Bjerringbro (Denmark)

    2017-04-15

    We did a numerical study of the internal flow field of a vortex pump. Five operating points were considered and validated through a measured characteristic curve. The internal flow pattern of a vortex pump was analyzed and compared to the Hamel-Oseen vortex model. The calculated flow field was assessed with respect to the circumferential velocity, the vorticity and the axial velocity. Whereas the trajectories of the circumferential velocity were largely in line with the Hamel-Oseen vortex model, the opposite was true for vorticity. Only the vorticity at strong part load was in line with the predictions of the Hamel-Oseen vortex model. We therefore compared the circumferential velocity and vorticity for strong part load operation to the analytical predictions of the Hamel-Oseen vortex model. The simulated values were below the analytical values. The study therefore suggests that a vortex similar to the Hamel-Oseen vortex is only present at the strong part load operation.

  15. Cerebral blood flow and metabolism during controlled hypotension with sodium-nitroprusside and general anaesthesia for total hip replacement a.m. Charnley

    International Nuclear Information System (INIS)

    Buenemann, L.; Jensen, K.; Thomsen, L.; Riisager, S.

    1987-01-01

    Cerebral blood flow (CBF) and cerebral metabolic rate of oxygen (CMRo 2 ) were studied during hypotension induced with sodium nitroprusside (SNP) in 10 patients undergoing total hip replacement a.m. Charnley. Cerebral blood flow was measured using an injection of xenon-133 into an arm vein. The decay curve was detected by five scintillation counters placed over each hemisphere and analysed with the Novo 10a cerebrograph. Blood samples were drawn from the radial artery and the jugular venous bulb to calculate the CMRo 2 . In the gropu as a whole, there were significant decreases in mean arterial pressure and in cerebrovascular resistance. There were no significant changes, in either CBF or CMRo 2 in the gropu as a whole, but there were substantial individual differences. In conclusion, the use of SNP-induced hypotension for extracranial surgery should be used only in patients monitored closely. (author)

  16. Comparative analysis of total mercury concentrations in anadromous and non-anadromous Arctic charr (Salvelinus alpinus) from eastern Canada

    International Nuclear Information System (INIS)

    Velden, S. van der; Evans, M.S.; Dempson, J.B.; Muir, D.C.G.; Power, M.

    2013-01-01

    Previous research has documented that total mercury concentrations ([THg]) are lower in anadromous Arctic charr than in non-anadromous conspecifics, but the two life-history forms have rarely been studied together. Here, data from nine pairs of closely-located anadromous and non-anadromous Arctic charr populations were used to explore the impact of biological and life-history factors on individual [THg] across a range of latitudes (49–81° N) in eastern Canada. Unadjusted mean [THg] ranged from 20 to 114 ng/g wet weight (ww) in anadromous populations, and was significantly higher in non-anadromous populations, ranging from 111 to 227 ng/g ww. Within-population variations in [THg] were best explained by fish age, and were often positively related to fork-length and δ 15 N-inferred trophic level. Differences in [THg] were not related to differences in length-at-age (i.e., average somatic growth rate) among populations of either life-history type. Mercury concentrations were not related to site latitude in either the anadromous or non-anadromous fish. We conclude that the difference in Arctic charr [THg] with life-history type could not be explained by differences in fish age, fork-length, trophic position, or length-at-age, and discuss possible factors contributing to low mercury concentrations in anadromous, relative to freshwater, fish. - Highlights: ► Total mercury concentrations ([THg]) were measured in 9 co-located anadromous and non-anadromous Arctic charr populations. ► Mean [THg] in non-anadromous populations exceeded mean [THg] in spatially paired anadromous populations. ► Among-individual variation in [THg] was best explained by fish age. ► The lower [THg] in anadromous fish could not be explained by differences in age, fork-length, trophic level, or growth rate. ► Variations in Arctic charr [THg] were independent of latitude (49–81° N) in eastern Canada

  17. Comparability of slack water and Lagrangian flow respirometry methods for community metabolic measurements.

    Directory of Open Access Journals (Sweden)

    Emily C Shaw

    Full Text Available Coral reef calcification is predicted to decline as a result of ocean acidification and other anthropogenic stressors. The majority of studies predicting declines based on in situ relationships between environmental parameters and net community calcification rate have been location-specific, preventing accurate predictions for coral reefs globally. In this study, net community calcification and production were measured on a coral reef flat at One Tree Island, Great Barrier Reef, using Lagrangian flow respirometry and slack water methods. Net community calcification, daytime net photosynthesis and nighttime respiration were higher under the flow respirometry method, likely due to increased water flow relative to the slack water method. The two methods also varied in the degrees to which they were influenced by potential measurement uncertainties. The difference in the results from these two commonly used methods implies that some of the location-specific differences in coral reef community metabolism may be due to differences in measurement methods.

  18. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    Science.gov (United States)

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.

  19. FLOW (finding lasting options for women): multicentre randomized controlled trial comparing tampons with menstrual cups.

    Science.gov (United States)

    Howard, Courtney; Rose, Caren Lee; Trouton, Konia; Stamm, Holly; Marentette, Danielle; Kirkpatrick, Nicole; Karalic, Sanja; Fernandez, Renee; Paget, Julie

    2011-06-01

    To determine whether menstrual cups are a viable alternative to tampons. Randomized controlled trial. Prince George, Victoria, and Vancouver, BC. A total of 110 women aged 19 to 40 years who had previously used tampons as their main method of menstrual management. Participants were randomized into 2 groups, a tampon group and a menstrual cup group. Using online diaries, participants tracked 1 menstrual cycle using their regular method and 3 menstrual cycles using the method of their allocated group. Overall satisfaction; secondary outcomes included discomfort, urovaginal infection, cost, and waste. Forty-seven women in each group completed the final survey, 5 of whom were subsequently excluded from analysis (3 from the tampon group and 2 from the menstrual cup group). Overall satisfaction on a 7-point Likert scale was higher for the menstrual cup group than for the tampon group (mean [standard deviation] score 5.4 [1.5] vs 5.0 [1.0], respectively; P=.04). Approximately 91% of women in the menstrual cup group said they would continue to use the cup and recommend it to others. Women used a median of 13 menstrual products per cycle, or 169 products per year, which corresponds to approximately 771,248,400 products used annually in Canada. Estimated cost for tampon use was $37.44 a year (similar to the retail cost of 1 menstrual cup). Subjective vaginal discomfort was initially higher in the menstrual cup group, but the discomfort decreased with continued use. There was no significant difference in physician-diagnosed urovaginal symptoms between the 2 groups. Both of the menstrual management methods evaluated were well tolerated by subjects. Menstrual cups are a satisfactory alternative to tampons and have the potential to be a sustainable solution to menstrual management, with moderate cost savings and much-reduced environmental effects compared with tampons. Trial registration number C06-0478 (ClinicalTrials.gov).

  20. Comparably improved health-related quality of life after total arterial revascularization versus conventional coronary surgery--Copenhagen arterial revascularization randomized patency and outcome trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Lund, Jens T; Lilleør, Nikolaj B

    2011-01-01

    OBJECTIVE: We compared health-related quality of life up to 11 months after coronary artery bypass grafting using total arterial revascularization versus conventional coronary surgery. METHODS: In this randomized single-center trial, 161 patients underwent total arterial revascularization using.......01). For total arterial revascularization, there were also not statistically significant improvements for 'physical component summary' (P=0.09), 'bodily pain' (P=0.07) and 'vitality' (P=0.08). CONCLUSION: Health-related quality of life up to 1 year after total arterial revascularization is equal or slightly...... of the general Danish population. On all scales of the SF-36, there was statistically significant improvement at 3 and 11 months in both groups. For 'social functioning', the improvement following total arterial revascularization was significantly higher than following conventional revascularization (P=0...

  1. SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET

    DEFF Research Database (Denmark)

    Yonekura, Y; Nishizawa, S; Mukai, Thomas Søgaard

    1988-01-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography...... (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and r......CBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a "linearization algorithm" to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO...

  2. Rapid food decomposition by H2O2-H2SO4 for determination of total mercury by flow injection cold vapor atomic absorption spectrometry.

    Science.gov (United States)

    Zenebon, Odair; Sakuma, Alice M; Dovidauskas, Sergio; Okada, Isaura A; de, MaioFrancaD; Lichtig, Jaim

    2002-01-01

    A mixture of 50% H2O2-H2SO4 (3 + 1, v/v) was used for decomposition of food in open vessels at 80 degrees C. The treatment allowed rapid total mercury determination by flow injection cold vapor atomic absorption spectrometry. Cabbage, potatoes, peanuts paste, hazelnuts paste, oats, tomatoes and their derivatives, oysters, shrimps, prawns, shellfish, marine algae, and many kinds of fish were analyzed by the proposed methodology with a limit of quantitation of 0.86 +/- 0.08 microg/L mercury in the final solution. Reference materials tested also gave excellent recovery.

  3. Comparative assessment of PIV-based pressure evaluation techniques applied to a transonic base flow

    NARCIS (Netherlands)

    Blinde, P; Michaelis, D; van Oudheusden, B.W.; Weiss, P.E.; de Kat, R.; Laskari, A.; Jeon, Y.J.; David, L; Schanz, D; Huhn, F.; Gesemann, S; Novara, M.; McPhaden, C.; Neeteson, N.; Rival, D.; Schneiders, J.F.G.; Schrijer, F.F.J.

    2016-01-01

    A test case for PIV-based pressure evaluation techniques has been developed by constructing a simulated experiment from a ZDES simulation for an axisymmetric base flow at Mach 0.7. The test case comprises sequences of four subsequent particle images (representing multi-pulse data) as well as

  4. Comparing heat flow models for interpretation of precast quadratic pile heat exchanger thermal response tests

    DEFF Research Database (Denmark)

    Alberdi Pagola, Maria; Poulsen, Søren Erbs; Loveridge, Fleur

    2018-01-01

    This paper investigates the applicability of currently available analytical, empirical and numerical heat flow models for interpreting thermal response tests (TRT) of quadratic cross section precast pile heat exchangers. A 3D finite element model (FEM) is utilised for interpreting five TRTs by in...

  5. Comparative study of the performance of three cross-flow ceramic ...

    African Journals Online (AJOL)

    Several tests using water as effluent are used to analyse the performance of three types of microfiltration cross-flow ceramic membranes. Two of these membranes are commercial (Atech and Membralox/US Filter) and the third one is experimental. The main differences between them lie in their chemical composition ...

  6. Comparative PIV and LDA studies of Newtonian and non-Newtonian flows in an agitated tank.

    Science.gov (United States)

    Story, Anna; Jaworski, Zdzisław; Simmons, Mark J; Nowak, Emilia

    2018-01-01

    The paper presents results of an experimental study of the fluid velocity field in a stirred tank equipped with a Prochem Maxflo T (PMT) type impeller which was rotating at a constant frequency of N  = 4.1 or 8.2 s -1 inducing transitional ( Re  = 499 or 1307) or turbulent ( Re  = 2.43 × 10 4 ) flow of the fluid. The experiments were performed for a Newtonian fluid (water) and a non-Newtonian fluid (0.2 wt% aqueous solution of carboxymethyl cellulose, CMC) exhibiting mild viscoelastic properties. Measurements were carried out using laser light scattering on tracer particles which follow the flow (2-D PIV). For both the water and the CMC solution one primary and two secondary circulation loops were observed within the fluid volume; however, the secondary loops were characterized by much lower intensity. The applied PMT-type impeller produced in the Newtonian fluid an axial primary flow, whilst in the non-Newtonian fluid the flow was more radial. The results obtained in the form of the local mean velocity components were in satisfactory agreement with the literature data from LDA. Distribution of the shear rate in the studied system was also analyzed. For the non-Newtonian fluid an area was computed where the elastic force dominates over the viscous one. The area was nearly matching the region occupied by the primary circulation loop.

  7. Integer batch scheduling problems for a single-machine with simultaneous effect of learning and forgetting to minimize total actual flow time

    Directory of Open Access Journals (Sweden)

    Rinto Yusriski

    2015-09-01

    Full Text Available This research discusses an integer batch scheduling problems for a single-machine with position-dependent batch processing time due to the simultaneous effect of learning and forgetting. The decision variables are the number of batches, batch sizes, and the sequence of the resulting batches. The objective is to minimize total actual flow time, defined as total interval time between the arrival times of parts in all respective batches and their common due date. There are two proposed algorithms to solve the problems. The first is developed by using the Integer Composition method, and it produces an optimal solution. Since the problems can be solved by the first algorithm in a worst-case time complexity O(n2n-1, this research proposes the second algorithm. It is a heuristic algorithm based on the Lagrange Relaxation method. Numerical experiments show that the heuristic algorithm gives outstanding results.

  8. 14CO2 labeling: a reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crops

    International Nuclear Information System (INIS)

    Singh, Bhupinder; Ahuja, Sumedha; Pandey, Renu; Singhal, R.K.

    2014-01-01

    Ability of roots to release organic compounds in its rhizosphere is known to improve plant available nutrients and reduces heavy metal toxicity by immobilization. It is regarded as an important determinant of micro nutrient deficiency tolerance in plants. Uptake of nutrients and translocation of photoassimilates, on the other hand are governed by the strength of the transpiration stream and sink demand respectively. Measurement of vascular sap flow, thus, is critical for understanding of the translocation efficiency and consequently the sink demand that keeps changing during the crop growth cycle. Measurement of the root exudation capacity and the vascular sap flow is cumbersome and time consuming. Since, the exudates released by the roots and the photosynthates translocated between the source and the sink are essentially carbon compounds, use of labeled carbon as tag could potentially be exploited for a rapid and reliable measurement of exudation and vascular sap flow in crop plants. We report here the experimental results involving 14 C labeling of groundnut, a legume crop, as 14 CO 2 generated by acidification of sodium bicarbonate. An additional factor of seed gamma irradiation was used to generate variability in the root exudation and the sap flow. The 14 C release by the roots was compared against the 14 C transport in the vascular sap. An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  9. A randomized pilot study comparing the role of PEEP, O2 flow, and high-flow air for weaning of ventilatory support in very low birth weight infants

    Directory of Open Access Journals (Sweden)

    Chang-Yo Yang

    2018-04-01

    Full Text Available Background: There is a lack of evidence to guide step-wise weaning of positive pressure respiratory support for premature infants. This study sought to compare the efficacy of three weaning protocols we designed to facilitate weaning of very low birth weight (VLBW, less than 1500 g preterm infants from nasal continuous positive airway pressure (NCPAP support. Methods: This was a prospective, randomized, controlled trial of VLBW preterm infants who received positive pressure ventilatory support in our neonatal intensive care unit (NICU from April 2008 through March 2009. When these infants were weaned to CPAP as their last step of respiratory support, they would be randomly assigned to one of the following three groups as their further weaning methods (M: (M1 CPAP group, (M2 O2 flow group, and (M3 air flow group. The time period they needed to wean off any kind of respiratory support, as well as the likelihood of developing relevant prematurity related morbidities, were compared among patients using different weaning modalities. Results: 181 patients were enrolled in the study. Their gestational age (GA and birth weight (BW were 29.1 ± 2.5, 28.7 ± 2.4, 28.7 ± 2.4 (mean ± SD weeks and 1142 ± 232, 1099 ± 234, 1083 ± 219 g, in M1, M2 and M3, respectively. The time (period needed to wean off support was 16.0 ± 10.0 days (M1, 11.6 ± 6.4 days (M2, and 15.0 ± 8.9 days (M3, respectively (p = .033. Incidence of retinopathy of prematurity (ROP and bronchopulmonary dysplasia (BPD were both significantly higher in the O2 flow group (p = .048. Conclusions: Although using low oxygen flow significantly shortens CPAP weaning time, it may increase risks of BPD and ROP, both known to be related to oxygen toxicity. Unless the infant has BPD and is O2-dependent, clinicians should consider using air flow or just splinting with no support at all when weaning NCPAP. Key Words: weaning, nasal continuous positive airway pressure, very

  10. Model and Comparative Study for Flow of Viscoelastic Nanofluids with Cattaneo-Christov Double Diffusion.

    Directory of Open Access Journals (Sweden)

    Tasawar Hayat

    Full Text Available Here two classes of viscoelastic fluids have been analyzed in the presence of Cattaneo-Christov double diffusion expressions of heat and mass transfer. A linearly stretched sheet has been used to create the flow. Thermal and concentration diffusions are characterized firstly by introducing Cattaneo-Christov fluxes. Novel features regarding Brownian motion and thermophoresis are retained. The conversion of nonlinear partial differential system to nonlinear ordinary differential system has been taken into place by using suitable transformations. The resulting nonlinear systems have been solved via convergent approach. Graphs have been sketched in order to investigate how the velocity, temperature and concentration profiles are affected by distinct physical flow parameters. Numerical values of skin friction coefficient and heat and mass transfer rates at the wall are also computed and discussed. Our observations demonstrate that the temperature and concentration fields are decreasing functions of thermal and concentration relaxation parameters.

  11. A Comparative Study for Flow of Viscoelastic Fluids with Cattaneo-Christov Heat Flux.

    Science.gov (United States)

    Hayat, Tasawar; Muhammad, Taseer; Alsaedi, Ahmed; Mustafa, Meraj

    2016-01-01

    This article examines the impact of Cattaneo-Christov heat flux in flows of viscoelastic fluids. Flow is generated by a linear stretching sheet. Influence of thermal relaxation time in the considered heat flux is seen. Mathematical formulation is presented for the boundary layer approach. Suitable transformations lead to a nonlinear differential system. Convergent series solutions of velocity and temperature are achieved. Impacts of various influential parameters on the velocity and temperature are sketched and discussed. Numerical computations are also performed for the skin friction coefficient and heat transfer rate. Our findings reveal that the temperature profile has an inverse relationship with the thermal relaxation parameter and the Prandtl number. Further the temperature profile and thermal boundary layer thickness are lower for Cattaneo-Christov heat flux model in comparison to the classical Fourier's law of heat conduction.

  12. Riparian woodland encroachment following flow regulation: a comparative study of Mediterranean and Boreal streams

    Directory of Open Access Journals (Sweden)

    Dolores Bejarano M.

    2011-10-01

    Full Text Available Water development accompanying mankind development has turned rivers into endangered ecosystems. Improving the understanding of ecological responses to river management actions is a key issue for assuring sustainable water management. However, few studies have been published where ecological metrics have been quantified in response to various degrees of flow alteration. In this work, changes in natural distribution of trees and shrubs within the riparian corridor (as indicator of the ecological status of the fluvial ecosystem were quantified at multiple sites along a flow alteration gradient (as indicator of impact along two regulated river reaches, one Boreal and the other Mediterranean, each downstream of a dam. Based on the obtained relationships we evaluated differences in response trends related to local physico-climatic factors of the two biomes and regarding to differing life-forms. Woody vegetation establishment patterns represented objective indicators of ecological responses to flow alteration. We found different responses between life-forms. Both trees and shrubs migrated downwards to the channel after dam closure, but shrubs were most impacted under higher degrees of flow alteration in terms of lateral movement. In addition, our results show clear longitudinal recovery trends of natural patterns of tree and shrub distribution corresponding to a decrease in intensity of hydrologic alteration in the Boreal river. However, vegetation encroachment persisted along the entire Mediterranean study reach. This may result from a relatively low gradient of decrease of hydrologic alteration with distance from the dam, coupled with other overlapping pressures and the mediating effect of physico-climatic characteristics on vegetation responses.

  13. Comparing the determinants of fund flows in domestically managed Malaysian Islamic and conventional equity funds.

    OpenAIRE

    Othman, J.; Asutay, M.; Jamailan, N.

    2018-01-01

    Purpose: This paper aims to provide an empirical evidence on the fund flows-past return performance relationship by also considering the management expense ratio, the portfolio turnover, the fund size and the fund age of Islamic equity funds (IEF) investors in comparison with conventional equity funds (CEF) investors. Design/methodology/approach: By using panel data, the sample of Malaysian domestic managed equity funds are considered comprised of 20 individual funds from IEF a...

  14. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  15. Comparative study of turbulent mixing in jet in cross-flow configurations using LES

    International Nuclear Information System (INIS)

    Wegner, B.; Huai, Y.; Sadiki, A.

    2004-01-01

    Mixing processes in turbulent fluid motion are of fundamental interest in many situations in engineering practice. Due to its practical importance in a vast number of applications, the generic configuration of the jet in cross-flow has been studied extensively in the past. Recently, the question has received a lot of attention, whether the unsteady behavior of the jet in cross-flow can be influenced by either active or passive means in order to control and enhance the mixing process. In the present paper, we use the large eddy simulation (LES) methodology to investigate how turbulent mixing can be enhanced by varying the angle between the jet and the oncoming cross-flow. After validating the computations against measurements by Andreopoulos and Rodi, we analyze qualitatively and quantitatively the mixing process for three configurations with different angles. It is shown that the inclination influences the characteristics of vortical structures and secondary motion which in turn have an effect on the mixing process. Besides a PDF of the passive scalar and a scalar energy spectrum, a mixedness parameter is used to provide information with respect to the quality and rate of mixing

  16. A comparative study of the lattice Boltzmann and volume of fluid method for the rising bubble flows

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seung Yeob; Park, Cheon Tae; Choi, Suhn [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Recently, the lattice Boltzmann method (LBM) has gained much attention for its ability to simulate fluid flows, and for its potential advantages over a conventional CFD method. The key advantages of LBM are, (1) suitability for parallel computations, (2) absence of the need to solve the time-consuming Poisson equation for a pressure, and (3) an ease with the way multiphase flows, complex geometries and interfacial dynamics may be treated. Nevertheless, the LBM is considered as a mere alternative CFD tools, not a promising approach. The motion of the bubbles in a liquid has been the focus of both academic and practical interest. The central problem is the relationship between the rise velocity, bubble shape due to the interface deformation and flow field. The buoyancy effect due to density difference in the two phase flows is characterized with Eotvos and Morton numbers. In this study, a single bubble rising under a buoyancy is simulated with LBM and VOF based on conventional CFD method. The two simulation results are compared with the previous experiments. The main objective of the present work is to establish the lattice Boltzmann method as a viable tool for the simulation of multiphase or multi-component flows

  17. A comparative study of the lattice Boltzmann and volume of fluid method for the rising bubble flows

    International Nuclear Information System (INIS)

    Ryu, Seung Yeob; Park, Cheon Tae; Choi, Suhn

    2010-01-01

    Recently, the lattice Boltzmann method (LBM) has gained much attention for its ability to simulate fluid flows, and for its potential advantages over a conventional CFD method. The key advantages of LBM are, (1) suitability for parallel computations, (2) absence of the need to solve the time-consuming Poisson equation for a pressure, and (3) an ease with the way multiphase flows, complex geometries and interfacial dynamics may be treated. Nevertheless, the LBM is considered as a mere alternative CFD tools, not a promising approach. The motion of the bubbles in a liquid has been the focus of both academic and practical interest. The central problem is the relationship between the rise velocity, bubble shape due to the interface deformation and flow field. The buoyancy effect due to density difference in the two phase flows is characterized with Eotvos and Morton numbers. In this study, a single bubble rising under a buoyancy is simulated with LBM and VOF based on conventional CFD method. The two simulation results are compared with the previous experiments. The main objective of the present work is to establish the lattice Boltzmann method as a viable tool for the simulation of multiphase or multi-component flows

  18. Flow and linear coefficient of thermal expansion of four types of Base Plate waxes compared with ADA standard

    Directory of Open Access Journals (Sweden)

    Monzavi A

    2002-07-01

    Full Text Available Waxes have a lot of applications in dentistry. Such materials are of thermoplastic type that undergoes deformation in different temperatures. Two important properties of base plate waxes are flow and their coefficient of linear thermal expansion. Recently, different institutions, inside the country, produce dentistry waxes, while they have not been standardized. Consequently, consumers' dissatisfaction are observed. In this research, the two above- mentioned factors were compared between three kinds of Iranian waxes with Cavex that is foreign production, based on test number 24 of ADA. To measure the flow rate in the temperatures of 23, 37 and 45°c, Wilcoxon statistical analysis was used. The results showed that in 23°c, the flow rate of Cavex and Azardent waxes met ADA standards; however, it was not true for two others types. In 37°c, the flow of none of the waxes was standardized and in 45°c their flow was acceptable, moreover, thermal expansion coefficient, for Cavex and Azardent types, was based on ADA standard.

  19. Development and assessment of multi-dimensional flow model in MARS compared with the RPI air-water experiment

    International Nuclear Information System (INIS)

    Lee, Seok Min; Lee, Un Chul; Bae, Sung Won; Chung, Bub Dong

    2004-01-01

    The Multi-Dimensional flow models in system code have been developed during the past many years. RELAP5-3D, CATHARE and TRACE has its specific multi-dimensional flow models and successfully applied it to the system safety analysis. In KAERI, also, MARS(Multi-dimensional Analysis of Reactor Safety) code was developed by integrating RELAP5/MOD3 code and COBRA-TF code. Even though COBRA-TF module can analyze three-dimensional flow models, it has a limitation to apply 3D shear stress dominant phenomena or cylindrical geometry. Therefore, Multi-dimensional analysis models are newly developed by implementing three-dimensional momentum flux and diffusion terms. The multi-dimensional model has been assessed compared with multi-dimensional conceptual problems and CFD code results. Although the assessment results were reasonable, the multi-dimensional model has not been validated to two-phase flow using experimental data. In this paper, the multi-dimensional air-water two-phase flow experiment was simulated and analyzed

  20. Comparative empirical analysis of flow-weighted transit route networks in R-space and evolution modeling

    Science.gov (United States)

    Huang, Ailing; Zang, Guangzhi; He, Zhengbing; Guan, Wei

    2017-05-01

    Urban public transit system is a typical mixed complex network with dynamic flow, and its evolution should be a process coupling topological structure with flow dynamics, which has received little attention. This paper presents the R-space to make a comparative empirical analysis on Beijing’s flow-weighted transit route network (TRN) and we found that both the Beijing’s TRNs in the year of 2011 and 2015 exhibit the scale-free properties. As such, we propose an evolution model driven by flow to simulate the development of TRNs with consideration of the passengers’ dynamical behaviors triggered by topological change. The model simulates that the evolution of TRN is an iterative process. At each time step, a certain number of new routes are generated driven by travel demands, which leads to dynamical evolution of new routes’ flow and triggers perturbation in nearby routes that will further impact the next round of opening new routes. We present the theoretical analysis based on the mean-field theory, as well as the numerical simulation for this model. The results obtained agree well with our empirical analysis results, which indicate that our model can simulate the TRN evolution with scale-free properties for distributions of node’s strength and degree. The purpose of this paper is to illustrate the global evolutional mechanism of transit network that will be used to exploit planning and design strategies for real TRNs.

  1. Cerebral blood flow changes in response to elevated intracranial pressure in rabbits and bluefish: a comparative study.

    Science.gov (United States)

    Beiner, J M; Olgivy, C S; DuBois, A B

    1997-03-01

    In mammals, the cerebrovascular response to increases in intracranial pressure may take the form of the Cushing response, which includes increased mean systemic arterial pressure, bradycardia and diminished respirations. The mechanism, effect and value of these responses are debated. Using laser-Doppler flowmetry to measure cerebral blood flow, we analyzed the cardiovascular responses to intracranial pressure raised by epidural infusion of mock cerebrospinal fluid in the bluefish and in the rabbit, and compare the results. A decline in cerebral blood flow preceding a rise in mean systemic arterial pressure was observed in both species. Unlike bluefish, rabbits exhibit a threshold of intracranial pressure below which cerebral blood flow was maintained and no cardiovascular changes were observed. The difference in response between the two species was due to the presence of an active autoregulatory system in the cerebral tissue of rabbits and its absence in bluefish. For both species studied, the stimulus for the Cushing response seems to be a decrement in cerebral blood flow. The resulting increase in the mean systemic arterial pressure restores cerebral blood flow to levels approaching controls.

  2. Flujo y concentración de proteínas en saliva total humana Salivary flow rate and protein concentration in human whole saliva

    Directory of Open Access Journals (Sweden)

    JOSÉ ANTONIO BANDERAS-TARABAY

    1997-09-01

    Full Text Available Objetivo. Determinar los promedios de flujo salival y la concentración de proteínas totales en una población joven del Estado de México. Material y métodos. Se seleccionaron 120 sujetos a quienes se les colectó saliva total humana (STH no estimulada y estimulada, la cual se analizó por medio de gravimetría y espectrofotometría (LV/LU; se calcularon medidas de tendencia central y de dispersión; posteriormente, se correlacionaron estos datos con los índices CPOD y CPITN. Resultados. Los sujetos estudiados mostraron un promedio de flujo salival (ml/min ± DE en STH no estimulada de 0.397±.26, y en STH estimulada, de 0.973±.53. El promedio en la concentración de proteínas (mg/ml ± DE fue de 1.374±.45 en STH no estimulada y de 1.526±.44 en STH estimulada. Las mujeres presentaron un menor porcentaje de flujo salival y mayor concentración de proteínas. No se observaron correlaciones entre el flujo y la concentración de proteínas totales y el CPOD y CPITN; sin embargo, sí las hubo con otras variables. Conclusiones. Estos hallazgos podrían estar asociados con el grado de nutrición, las características genéticas y los niveles de salud bucal en nuestra población. El presente estudio representa la fase inicial de la creación de una base de datos en sialoquímica, cuya meta será identificar los parámetros que indiquen el riesgo de enfermedades sistémicas o bucodentales.Objective. To determine the average salivary flow rates and total protein concentrations in a population of the State of Mexico. Material and methods. A gravimetric and spectrophotometric analysis was applied to 120 subjects in total resting and stimulated whole saliva and results were correlated with the DMFT and CPITN indexes. Results. Subjects allowed average salivary flow rate (ml/min ± SD in non-stimulated human whole saliva (HWS of 0.397±.26 and in stimulated HWS of 0.973±.53. Average protein concentration was (mg/ml ± SD 1.374±.45 in non

  3. Structural imaging of the brain reveals decreased total brain and total gray matter volumes in obese but not in lean women with polycystic ovary syndrome compared to body mass index-matched counterparts.

    Science.gov (United States)

    Ozgen Saydam, Basak; Has, Arzu Ceylan; Bozdag, Gurkan; Oguz, Kader Karli; Yildiz, Bulent Okan

    2017-07-01

    To detect differences in global brain volumes and identify relations between brain volume and appetite-related hormones in women with polycystic ovary syndrome (PCOS) compared to body mass index-matched controls. Forty subjects participated in this study. Cranial magnetic resonance imaging and measurements of fasting ghrelin, leptin and glucagon-like peptide 1 (GLP-1), as well as GLP-1 levels during mixed-meal tolerance test (MTT), were performed. Total brain volume and total gray matter volume (GMV) were decreased in obese PCOS compared to obese controls (p lean PCOS and controls did not show a significant difference. Secondary analyses of regional brain volumes showed decreases in GMV of the caudate nucleus, ventral diencephalon and hippocampus in obese PCOS compared to obese controls (p lean patients with PCOS had lower GMV in the amygdala than lean controls (p PCOS, suggests volumetric reductions in global brain areas in obese women with PCOS. Functional studies with larger sample size are needed to determine physiopathological roles of these changes and potential effects of long-term medical management on brain structure of PCOS.

  4. Assessment of Total Phenolic and Flavonoid Content, Antioxidant Properties, and Yield of Aeroponically and Conventionally Grown Leafy Vegetables and Fruit Crops: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Suman Chandra

    2014-01-01

    Full Text Available A comparison of the product yield, total phenolics, total flavonoids, and antioxidant properties was done in different leafy vegetables/herbs (basil, chard, parsley, and red kale and fruit crops (bell pepper, cherry tomatoes, cucumber, and squash grown in aeroponic growing systems (AG and in the field (FG. An average increase of about 19%, 8%, 65%, 21%, 53%, 35%, 7%, and 50% in the yield was recorded for basil, chard, red kale, parsley, bell pepper, cherry tomatoes, cucumber, and squash, respectively, when grown in aeroponic systems, compared to that grown in the soil. Antioxidant properties of AG and FG crops were evaluated using 2,2-diphenyl-1-picrylhydrazyl (DDPH and cellular antioxidant (CAA assays. In general, the study shows that the plants grown in the aeroponic system had a higher yield and comparable phenolics, flavonoids, and antioxidant properties as compared to those grown in the soil.

  5. Comparative Study between Perfusion Changes and Positive Findings on Coronary Flow Reserve

    Directory of Open Access Journals (Sweden)

    Costantino Roberto Frack Costantini

    Full Text Available Abstract Background: Functional assessment of coronary artery obstruction is used in cardiology practice to correlate anatomic obstructions with flow decrease. Among such assessments, the study of the coronary fractional flow reserve (FFR has become the most widely used. Objective: To evaluate the correlation between FFR and findings of ischemia obtained by noninvasive methods including stress echocardiography and nuclear medicine and the presence of critical coronary artery obstruction. Methods: Retrospective study of cases treated with systematized and standardized procedures for coronary disease between March 2011 and August 2014. We included 96 patients with 107 critical coronary obstructions (> 50% in the coronary trunk and/or ≥ 70% in other segments estimated by quantitative coronary angiography (QCA and intracoronary ultrasound (ICUS. All cases presented ischemia in one of the noninvasive studies. Results: All 96 patients presented ischemia (100% in one of the functional tests. On FFR study with adenosine 140 g/kg/min, 52% of the cases had values ≤ 0.80. On correlation analysis for FFR ≤ 0.80, the evaluation of sensitivity, specificity, positive and negative predictive values, accuracy, and ROC curve in relation to the stenosis degree and length, and presence of ischemia, no significant values or strong correlation were observed. Conclusion: Coronary FFR using a cut-off value of 0.80 showed no correlation with noninvasive ischemia tests in patients with severe coronary artery obstructions on QCA and ICUS.

  6. A total pressure-saturation formulation of two-phase flow incorporating dynamic effects in the capillary-pressure-saturation relationship

    Energy Technology Data Exchange (ETDEWEB)

    Dahle, H K; Celia, M A; Hassanizadeh, S M; Karlsen, K H

    2002-07-01

    New theories suggest that the relationship between capillary pressure and saturation should be enhanced by a dynamic term that is proportional to the time rate of change of saturation. This so-called dynamic capillary pressure formulation is supported by laboratory experiments, and can be included in various forms of the governing equations for two-phase flow in porous media. An extended model of two-phase flow in porous media may be developed based on fractional flow curves and a total pressure - saturation description that includes the dynamic capillary pressure terms. A dimensionless form of the resulting equation set provides an ideal tool to study the relative importance of the dynamic capillary pressure effect. This equation provides a rich set of mathematical research questions, and numerical solutions to the equation provide insights into the behavior of two-phase immiscible flow. For typical two-phase flow systems, dynamic capillary pressure acts to retard infiltration fronts, with responses dependent on system parameters including boundary conditions. Recent theoretical work suggests that the traditional algebraic relationship between capillary pressure and saturation may be inadequate. Instead, a so-called dynamic capillary pressure formulation is needed, where capillary pressure is defined as a thermodynamic variable, and the difference between phase pressures is only equal to the capillary pressure at equilibrium. Under dynamic conditions, the disequilibrium between phase-pressure differences and the capillary pressure is taken to be proportional to the time rate of change of saturation. A recent study by Hassanizadeh et al. presents experimental evidence, culled from the literature, to support this claim. Numerical simulations using dynamic pore-scale network models and upscaling also support the claim. Hassanizadeh et al. also presented numerical solutions for an enhanced version of Richards' equation that included the dynamic terms. A preliminary

  7. Comparing DNS and Experiments of Subcritical Flow Past an Isolated Surface Roughness Element

    Science.gov (United States)

    Doolittle, Charles; Goldstein, David

    2009-11-01

    Results are presented from computational and experimental studies of subcritical roughness within a Blasius boundary layer. This work stems from discrepancies presented by Stephani and Goldstein (AIAA Paper 2009-585) where DNS results did not agree with hot-wire measurements. The near wake regions of cylindrical surface roughness elements corresponding to roughness-based Reynolds numbers Rek of about 202 are of specific concern. Laser-Doppler anemometry and flow visualization in water, as well as the same spectral DNS code used by Stephani and Goldstein are used to obtain both quantitative and qualitative comparisons with previous results. Conclusions regarding previous studies will be presented alongside discussion of current work including grid resolution studies and an examination of vorticity dynamics.

  8. Flow properties of MK-based geopolymer pastes. A comparative study with standard Portland cement pastes.

    Science.gov (United States)

    Favier, Aurélie; Hot, Julie; Habert, Guillaume; Roussel, Nicolas; d'Espinose de Lacaillerie, Jean-Baptiste

    2014-02-28

    Geopolymers are presented in many studies as alternatives to ordinary Portland cement. Previous studies have focused on their chemical and mechanical properties, their microstructures and their potential applications, but very few have focussed on their rheological behaviour. Our work highlights the fundamental differences in the flow properties, which exist between geopolymers made from metakaolin and Ordinary Portland Cement (OPC). We show that colloidal interactions between metakaolin particles are negligible and that hydrodynamic effects control the rheological behaviour. Metakaolin-based geopolymers can then be described as Newtonian fluids with the viscosity controlled mainly by the high viscosity of the suspending alkaline silicate solution and not by the contribution of direct contacts between metakaolin grains. This fundamental difference between geopolymers and OPC implies that developments made in cement technology to improve rheological behaviour such as plasticizers will not be efficient for geopolymers and that new research directions need to be explored.

  9. Comparative analysis of food webs based on flow networks: effects of nutrient supply on structure and function of coastal plankton communities

    Science.gov (United States)

    Olsen, Yngvar; Reinertsen, Helge; Vadstein, Olav; Andersen, Tom; Gismervik, Ingrid; Duarte, Carlos; Agusti, Susana; Stibor, Herwig; Sommer, Ulrich; Lignell, Risto; Tamminen, Timo; Lancelot, Christiane; Rousseau, Veronique; Hoell, Espen; Sanderud, Knut Arvid

    2001-12-01

    The objective of COMWEB was to develop efficient analytical, numerical and experimental methods for assessing and predicting the effects of nutrient (N, P, Si) supply on the stability and persistence of pelagic food web structure and function in coastal waters. The experimental comparative work included a geographic gradient covering Baltic, Mediterranean, and NE Atlantic waters and a NE Atlantic gradient in state of eutrophication. COMWEB has been an experimental approach to coastal eutrophication, studying effects of enhanced nutrient supply on components and flows of the entire lower pelagic food web. Flow network representations of pelagic food webs has been a framework of data reduction and flows were established by sophisticated inverse modelling. Fundamental information on physiological properties of functional key species in the pelagic food web was used to constrain flow estimations. A main conclusion derived from the flow networks was that very little energy and materials were transferred from the microbial food web to the main food chain. The lower food web could therefore be described as two parallel food chains with relatively limited interaction between heterotrophic groups. Short-term effects of nutrient perturbations were examined in mesocosms along the geographic gradient. The response was comparable in all systems, with a stronger effect on the activity and biomass of autotrophic groups than those of heterotrophic ones. Mediterranean waters showed much lower autotrophic biomass response than Baltic and NE Atlantic waters, which responded almost equally. The response of primary production was, however, more comparable. High phytoplankton lysis rate explained this low accumulation of biomass in Mediterranean waters. The study of Atlantic coastal waters of different eutrophic states revealed that the ecological response was higher in the closed nutrient perturbed mesocosms than in open systems exposed for >4 summer months (summer/autumn season). The

  10. A comparative numerical analysis of linear and nonlinear aerodynamic sound generation by vortex disturbances in homentropic constant shear flows

    International Nuclear Information System (INIS)

    Hau, Jan-Niklas; Oberlack, Martin; Chagelishvili, George; Khujadze, George; Tevzadze, Alexander

    2015-01-01

    Aerodynamic sound generation in shear flows is investigated in the light of the breakthrough in hydrodynamics stability theory in the 1990s, where generic phenomena of non-normal shear flow systems were understood. By applying the thereby emerged short-time/non-modal approach, the sole linear mechanism of wave generation by vortices in shear flows was captured [G. D. Chagelishvili, A. Tevzadze, G. Bodo, and S. S. Moiseev, “Linear mechanism of wave emergence from vortices in smooth shear flows,” Phys. Rev. Lett. 79, 3178-3181 (1997); B. F. Farrell and P. J. Ioannou, “Transient and asymptotic growth of two-dimensional perturbations in viscous compressible shear flow,” Phys. Fluids 12, 3021-3028 (2000); N. A. Bakas, “Mechanism underlying transient growth of planar perturbations in unbounded compressible shear flow,” J. Fluid Mech. 639, 479-507 (2009); and G. Favraud and V. Pagneux, “Superadiabatic evolution of acoustic and vorticity perturbations in Couette flow,” Phys. Rev. E 89, 033012 (2014)]. Its source is the non-normality induced linear mode-coupling, which becomes efficient at moderate Mach numbers that is defined for each perturbation harmonic as the ratio of the shear rate to its characteristic frequency. Based on the results by the non-modal approach, we investigate a two-dimensional homentropic constant shear flow and focus on the dynamical characteristics in the wavenumber plane. This allows to separate from each other the participants of the dynamical processes — vortex and wave modes — and to estimate the efficacy of the process of linear wave-generation. This process is analyzed and visualized on the example of a packet of vortex modes, localized in both, spectral and physical, planes. Further, by employing direct numerical simulations, the wave generation by chaotically distributed vortex modes is analyzed and the involved linear and nonlinear processes are identified. The generated acoustic field is anisotropic in the wavenumber

  11. Patient Participation at Health Care Conferences: Engaged Patients Increase Information Flow, Expand Propagation, and Deepen Engagement in the Conversation of Tweets Compared to Physicians or Researchers.

    Science.gov (United States)

    Utengen, Audun; Rouholiman, Dara; Gamble, Jamison G; Grajales, Francisco Jose; Pradhan, Nisha; Staley, Alicia C; Bernstein, Liza; Young, Sean D; Clauson, Kevin A; Chu, Larry F

    2017-08-17

    Health care conferences present a unique opportunity to network, spark innovation, and disseminate novel information to a large audience, but the dissemination of information typically stays within very specific networks. Social network analysis can be adopted to understand the flow of information between virtual social communities and the role of patients within the network. The purpose of this study is to examine the impact engaged patients bring to health care conference social media information flow and how they expand dissemination and distribution of tweets compared to other health care conference stakeholders such as physicians and researchers. From January 2014 through December 2016, 7,644,549 tweets were analyzed from 1672 health care conferences with at least 1000 tweets who had registered in Symplur's Health Care Hashtag Project from 2014 to 2016. The tweet content was analyzed to create a list of the top 100 influencers by mention from each conference, who were then subsequently categorized by stakeholder group. Multivariate linear regression models were created using stepwise function building to identify factors explaining variability as predictor variables for the model in which conference tweets were taken as the dependent variable. Inclusion of engaged patients in health care conference social media was low compared to that of physicians and has not significantly changed over the last 3 years. When engaged patient voices are included in health care conferences, they greatly increase information flow as measured by total tweet volume (beta=301.6) compared to physicians (beta=137.3, Psocial media impressions created (beta=1,700,000) compared to physicians (beta=270,000, PSocial network analysis of hubs and authorities revealed that patients had statistically significant higher hub scores (mean 8.26×10-4, SD 2.96×10-4) compared to other stakeholder groups' Twitter accounts (mean 7.19×10-4, SD 3.81×10-4; t273.84=4.302, Psocial media of health care

  12. Alterations of total non stimulated salivary flow in patients with squamous cell carcinoma of the mouth and oropharynx submitted to hyperfractionated radiation therapy

    International Nuclear Information System (INIS)

    Guebur, Maria Isabela; Rapoport, Abrao; Sassi, Laurindo Moacir; Oliveira, Benedito Valdecir de; Ramos, Gyl Henrique Albrecht; Pereira, Jose Carlos Gasparin

    2004-01-01

    Prevention and early diagnosis are actually the most effective measures that we dispose to improve the prognostic of the malignant tumors. The mouth and oropharynx tumors are treated with success, when early diagnosed. The radiotherapy is almost always one of the selected treatments for these tumors. When cancer is diagnosed in advanced stages, many a time the treatment needs to be carried out swiftly to be efficient, and consequently the radio therapist use the hyperfractionated therapy, with the patient receiving two lower doses of radiation in two sessions daily, amounting to a higher daily dosage, of about 160 cGy/2x/day. When the major salivary glands are present in the radiated field, the xerostomia appears by the second week of treatment (1500 to 2000 cGy), changing the patient's health, and causing difficulties for him to eat, speak and sleep. The objective of this study was to evaluate the quantitative alterations of the total non stimulated salivate flow of patients who underwent hyperfractionated therapy for the treatment of squamous cell carcinoma of mouth and oropharynx. Samples of twelve male patients saliva from Erasto Gaertner Hospital in Curitiba, PR, Brazil, were examined. Two samples of saliva were collected from each patient, the first one before the beginning of the radiotherapy, and the second at the end of the treatment. As a result, we obtained salivary loss in 91.7% of the patients, with a percentage of total salivary flow loss of 62.9%, registered in the second collection. We concluded that the hyperfractionated therapy causes a marked xerostomia when the major salivary glands are in the radiated field. (author)

  13. Quantitative measurement of portal blood flow by magnetic resonance phase contrast. Comparative study of flow phantom and Doppler ultrasound in vivo

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Hamazaki, Keisuke; Takeda, Yoshihiro; Hiraki, Yoshio.

    1994-01-01

    A non-invasive method for measuring portal blood flow by magnetic resonance (MR) phase contrast was evaluated in a flow phantom and 20 healthy volunteers. In a flow phantom study, the flow volumes and mean flow velocities measured by MR phase contrast showed close correlations with those measured by electromagnetic flow-metry. In 20 healthy volunteers, the cross-sectional areas, flow volumes and mean flow velocities measured by MR phase contrast correlated well with those measured by the Doppler ultrasound method. Portal blood flow averaged during the imaging time could be measured under natural breathing conditions by using a large number of acquisitions without the limitations imposed on the Doppler ultrasound method. MR phase contrast is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  14. PET quantification with a histogram derived total activity metric: Superior quantitative consistency compared to total lesion glycolysis with absolute or relative SUV thresholds in phantoms and lung cancer patients

    International Nuclear Information System (INIS)

    Burger, Irene A.; Vargas, Hebert Alberto; Apte, Aditya; Beattie, Bradley J.; Humm, John L.; Gonen, Mithat; Larson, Steven M.; Ross Schmidtlein, C.

    2014-01-01

    Introduction: The increasing use of molecular imaging probes as biomarkers in oncology emphasizes the need for robust and stable methods for quantifying tracer uptake in PET imaging. The primary motivation for this research was to find an accurate method to quantify the total tumor uptake. Therefore we developed a histogram-based method to calculate the background subtracted lesion (BSL) activity and validated BSL by comparing the quantitative consistency with the total lesion glycolysis (TLG) in phantom and patient studies. Methods: A thorax phantom and a PET-ACR quality assurance phantom were scanned with increasing FDG concentrations. Volumes of interest (VOIs) were placed over each chamber. TLG was calculated with a fixed threshold at SUV 2.5 (TLG 2.5 ) and a relative threshold at 42% of SUV max (TLG 42% ). The histogram for each VOI was built and BSL was calculated. Comparison with the total injected FDG activity (TIA) was performed using concordance correlation coefficients (CCC) and the slope (a). Fifty consecutive patients with FDG-avid lung tumors were selected under an IRB waiver. TLG 42% , TLG 2.5 and BSL were compared to the reference standard calculating CCC and the slope. Results: In both phantoms, the CCC for lesions with a TIA ≤ 50 ml*SUV between TIA and BSL was higher and the slope closer to 1 (CCC = 0.933, a = 1.189), than for TLG 42% (CCC = 0.350, a = 0.731) or TLG 2.5 (CCC = 0.761, a = 0.727). In 50 lung lesions BSL had a slope closer to 1 compared to the reference activity than TLG 42% (a = 1.084 vs 0.618 – for high activity lesions) and also closer to 1 than TLG 2.5 (a = 1.117 vs 0.548 – for low activity lesions). Conclusion: The histogram based BSL correlated better with TIA in both phantom studies than TLG 2.5 or TLG 42% . Also in lung tumors, the BSL activity is overall more accurate in quantifying the lesion activity compared to the two most commonly applied TLG quantification methods

  15. Direct hospital costs of total laparoscopic hysterectomy compared with fast-track open hysterectomy at a tertiary hospital: a retrospective case-controlled study.

    Science.gov (United States)

    Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan

    2015-12-01

    To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  16. Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement

    Science.gov (United States)

    Jain, Sunil

    2008-01-01

    Our objective was to assess and validate low-dose computed tomography (CT) scanogram as a post-operative imaging modality to measure the mechanical axis after navigated total knee replacement. A prospective study was performed to compare intra-operative and post-operative mechanical axis after navigated total knee replacements. All consecutive patients who underwent navigated total knee replacement between May and December 2006 were included. The intra-operative final axis was recorded, and post-operatively a CT scanogram of lower limbs was performed. The mechanical axis was measured and compared against the intra-operative measurement. There were 15 patients ranging in age from 57 to 80 (average 70) years. The average final intra-operative axis was 0.56° varus (4° varus to 1.5° valgus) and post-operative CT scanogram axis was 0.52° varus (3.1° varus to 1.8° valgus). The average deviation from final axes to CT scanogram axes was 0.12° valgus with a correlation coefficient of 0.9. Our study suggests that CT scanogram is an imaging modality with reasonable accuracy for measuring mechanical axis despite significantly low radiation. It also confirms a high level of correlation between intra-operative and post-operative mechanical axis after navigated total knee replacement. PMID:18696064

  17. Comparative study of the second antibody for radioimmunoassay totally produced in the country to a similar imported one (sheep serum anti-rabbit IgG)

    International Nuclear Information System (INIS)

    Silva, S.R. da; Borghi, V.C.; Wajchenberg, B.L.

    1992-01-01

    This work compares a second antibody for radioimmunoassay (RIA) produced at IPEN-CNEN/SP with a commercial one of known quality, produced by Radioassay Systems Laboratories, U.S.A.. This antiserum, sheep serum anti-rabbit IgG produced in its totality in the country, presented title and precipitation characteristics similar to those exhibited by the commercial product, being as suitable for the RIA separation as its imported similar. (author)

  18. Computing and Comparing Effective Properties for Flow and Transport in Computer-Generated Porous Media

    KAUST Repository

    Allen, Rebecca; Sun, Shuyu

    2017-01-01

    We compute effective properties (i.e., permeability, hydraulic tortuosity, and diffusive tortuosity) of three different digital porous media samples, including in-line array of uniform shapes, staggered-array of squares, and randomly distributed squares. The permeability and hydraulic tortuosity are computed by solving a set of rescaled Stokes equations obtained by homogenization, and the diffusive tortuosity is computed by solving a homogenization problem given for the effective diffusion coefficient that is inversely related to diffusive tortuosity. We find that hydraulic and diffusive tortuosity can be quantitatively different by up to a factor of ten in the same pore geometry, which indicates that these tortuosity terms cannot be used interchangeably. We also find that when a pore geometry is characterized by an anisotropic permeability, the diffusive tortuosity (and correspondingly the effective diffusion coefficient) can also be anisotropic. This finding has important implications for reservoir-scale modeling of flow and transport, as it is more realistic to account for the anisotropy of both the permeability and the effective diffusion coefficient.

  19. Comparative analysis of the flow activity of the Homoljska Potajnica intermittent spring

    Directory of Open Access Journals (Sweden)

    Igračev Nikola

    2014-01-01

    Full Text Available Homoljska Potajnica belongs to the type of a very rare, intermittent or rhythmic springs which appear exclusively in karst areas. It is one of the three known springs of this type in Serbia, while it is believed to be only about fifty of these in the rest of the world. As a rare karst and natural phenomenon, Homoljska Potajnica was a subject of interest for numerous researchers and geomorphologists in Serbia. Due to a very complex problem of occurence and the principle of functioning, to get the reliable data of how intemittent springs work, it is neccesarry to provide a continious observations, ussually in a long term period. This paper presents the results of the measurements of spring's flow activity and water discharge, taken in 2012. and 2013. These were carried out for comparison with the results of previous research, with an aim to determine possible changes in dynamics and mechanisms of spring's functioning in the past. One of the goals is to relate the annual precipitation regime with the intensity and frequency of spring activity, to try to determine the specific model of the spring's functioning. Another goal is to emphasize the need for continious observation in order to obtain the relevant data about the evolution of this rare natural phenomenon.

  20. Computing and Comparing Effective Properties for Flow and Transport in Computer-Generated Porous Media

    KAUST Repository

    Allen, Rebecca

    2017-02-13

    We compute effective properties (i.e., permeability, hydraulic tortuosity, and diffusive tortuosity) of three different digital porous media samples, including in-line array of uniform shapes, staggered-array of squares, and randomly distributed squares. The permeability and hydraulic tortuosity are computed by solving a set of rescaled Stokes equations obtained by homogenization, and the diffusive tortuosity is computed by solving a homogenization problem given for the effective diffusion coefficient that is inversely related to diffusive tortuosity. We find that hydraulic and diffusive tortuosity can be quantitatively different by up to a factor of ten in the same pore geometry, which indicates that these tortuosity terms cannot be used interchangeably. We also find that when a pore geometry is characterized by an anisotropic permeability, the diffusive tortuosity (and correspondingly the effective diffusion coefficient) can also be anisotropic. This finding has important implications for reservoir-scale modeling of flow and transport, as it is more realistic to account for the anisotropy of both the permeability and the effective diffusion coefficient.

  1. Comparative analysis of quadriceps and hamstrings strength in knee osteoarthritis before and after total knee arthroplasty: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Naasson Trindade Cavanellas

    Full Text Available ABSTRACT Objective: Compare the maximal isokinetic muscle strength of knee extensor and flexor muscles between patients with knee osteoarthritis and patients submitted to total knee arthroplasty. Methods: Volunteers were divided into five groups (n = 20: Control; Ahlbäck I and II; Ahlbäck IV; six months after total knee arthroplasty; 12 months after total knee arthroplasty. An isokinetic knee strength evaluation was conducted for the quadriceps and hamstrings at 60°/s. Results: Significant differences in the peak torque of the quadriceps and hamstrings were found among the groups (p < 0.001. The Ahlbäck IV, six-month, and 12-month postoperative groups demonstrated lower values when compared to the Control and Ahlbäck I and II groups. When percentage values were compared to the Control group, mean differences ranged from 7% to 41%. Conclusion: Patients with healthy knees or early stage osteoarthritis have higher quadriceps and hamstrings strengths than those with a more advanced stage of the disease, even after knee replacement. These findings suggest that the traditional rehabilitation programs do not recover strength to levels observed in individuals without knee osteoarthritis.

  2. COMPAR

    International Nuclear Information System (INIS)

    Kuefner, K.

    1976-01-01

    COMPAR works on FORTRAN arrays with four indices: A = A(i,j,k,l) where, for each fixed k 0 ,l 0 , only the 'plane' [A(i,j,k 0 ,l 0 ), i = 1, isub(max), j = 1, jsub(max)] is held in fast memory. Given two arrays A, B of this type COMPAR has the capability to 1) re-norm A and B ind different ways; 2) calculate the deviations epsilon defined as epsilon(i,j,k,l): =[A(i,j,k,l) - B(i,j,k,l)] / GEW(i,j,k,l) where GEW (i,j,k,l) may be chosen in three different ways; 3) calculate mean, standard deviation and maximum in the array epsilon (by several intermediate stages); 4) determine traverses in the array epsilon; 5) plot these traverses by a printer; 6) simplify plots of these traverses by the PLOTEASY-system by creating input data blocks for this system. The main application of COMPAR is given (so far) by the comparison of two- and three-dimensional multigroup neutron flux-fields. (orig.) [de

  3. Evaluation of T cell subsets by an immunocytochemical method compared to flow cytometry in four countries

    DEFF Research Database (Denmark)

    Lisse, I M; Böttiger, B; Christensen, L B

    1997-01-01

    The authors tested an alternative method for CD4 and CD8 T lymphocytes enumeration, the immunoalkaline phosphatase method (IA), in three African countries and in Denmark. The IA determinations from 136 HIV antibody positive and 105 HIV antibody negative individuals were compared...... by the two methods are not interchangeable as IA compared to FC consistently gives higher percentage of CD4 T lymphocytes, and lower percentage of CD8 T lymphocytes. Mean differences between the two methods did not differ between the three African countries indicating that the IA method provides systematic...... results. Replicate measurements suggested good correspondence between results obtained by IA. By using an IA level of 4 T lymphocytes/microliter, the sensitivity was 81% and specificity 96% for detecting an FC level of 4 T lymphocytes/microliter. Using an IA level of 4 T...

  4. A Closer Look at Revealed Comparative Advantage: Gross-versus Value Added Trade Flows

    OpenAIRE

    Brakman, Steven; van Marrewijk, Charles

    2015-01-01

    With the availability of international value added trade data it has become evident that gross export data and value added data do not provide the same information. Although gross exports crosses national borders and is the target of trade policy, value added data tell us what fragment in the production chain is internationally competitive in a particular country. With respect to comparative advantage the differences between the two types of data are often illustrated by means of examples usi...

  5. Pressure Wire Compared to Microcatheter Sensing for Coronary Fractional Flow Reserve: The PERFORM Study.

    Science.gov (United States)

    Ali, Ziad A; Parviz, Yasir; Brinkman, Matthew; Matsumura, Mitsuaki; Redfors, Björn; Brogno, David A; Corral, Maria D; Fall, Khady N; Mintz, Gary S; Stone, Gregg W; Maehara, Akiko; Jeremias, Allen; Kirtane, Ajay J

    2018-05-15

    Among technologies used to assess FFR, a monorail, sensor-tipped micro pressure catheter (PC) may be advantageous for delivery and re-assessment. We sought to determine whether the larger cross-sectional area of the PC influences FFR measurements compared to the pressure wire. PERFORM was a single-center, prospective study designed to determine the precision and accuracy of the PC compared with the pressure wire (PW) for measurement of FFR. Eligible patients had native coronary artery target lesions with visually estimated diameter stenosis of 40-90%. The independently adjudicated primary endpoint was the difference in hyperemic PW-determined minimal FFR with and without the PC distal to the stenosis. Seventy-four patients (95 lesions) were prospectively analyzed between December 2015 and December 2016. Median hyperemic FFR was 0.84 [IQR 0.78, 0.89] with the PW and 0.79 [IQR 0.73, 0.85] with the PC distal to the stenosis (p0.80 to ≤0.80 in 17 of 95 measurements (19%). Median resting Pd/Pa was lower following introduction of the PC compared with the PW alone (0.93 [IQR 0.90, 0.97] versus 0.90 [IQR 0.86, 0.95], p<0.001). Median pressure drift was not different between the PW and the PC (0.01 [IQR -0.01, 0.05] versus 0.01 [IQR 0.00, 0.02], p=0.38). Introduction of the PC reduced device success and both hyperemic FFR and resting Pd/Pa compared with the PW alone, leading to re-classifying physiological significance to below ischemic threshold in one out of five assessments.

  6. Characteristics of Cerebral Blood Flow in Vascular Dementia using SPM Analysis Compared to Normal Control and Alzheimer's Dementia

    International Nuclear Information System (INIS)

    Kang, Do Young; Park, Kyung Won; Kim, Jae Woo

    2003-01-01

    Cerebral perfusion pattern of vascular dementia (VD) was not well established and overlap of cerebral perfusion pattern was reported between VD and Alzheimer's dementia (AD). The aim of this study is to assess the specific patterns of SPECT finding in VD compared with normal control subjects and to disclose differences of cerebral blood flow between subjects with VD and AD were investigated using statistic parametric mapping analysis. Thirty-two VD (mean age ; 67.86.4 years, mean CDR ; 0.980.27), 51 AD (mean age ; 71.47.2 years, CDR ; 1.160.47), which were matched for age and severity of dementia, and 30 normal control subjects (mean age ; 60.17.7 years) participated in this study. The Tc-99m HMPAO brain perfusion SPECT data were analyzed by SPM99. The SPECT data of the patients with VD were compared to those of the control subjects and then compared to the patients with AD. SPM analysis of the SPECT image showed significant perfusion deficits in the both frontal (both cingulate gyrus, both inferior frontal gyrus, B no.47, right frontal rectal gyrus, left frontal subcallosal gyrus, B no.25), both temporal (right insula, B no.13, left superior temporal gyrus, left parahippocampal gyrus, B no.35), occipital (occipital lingual gyrus), right corpus callosum and right cerebellar tonsil regions in subjects with VD compared with normal control subjects (uncorrected p<0.01). Comparison of the two dementia groups (uncorrected p<0.01) revealed significant hypoperfusion in both parietal posterior central gyrus, right inferior frontal gyrus (B no.47), left insula, right thalamus (ventral lateral nucleus), right claustrum and right occipital cuneus regions in VD group compared with AD. There were no typical confined regional hypoperfusion areas but scattered multiple perfusion deficits in VD compared AD. These findings may be helpful to reflect the pathophysiological mechanisms of VD and to disclose differences of cerebral blood flow between subjects with VD and AD

  7. Functional outcome and quality of life after traumatic total brachial plexus injury treated by nerve transfer or single/double free muscle transfers: a comparative study.

    Science.gov (United States)

    Satbhai, N G; Doi, K; Hattori, Y; Sakamoto, S

    2016-02-01

    Between 2002 and 2011, 81 patients with a traumatic total brachial plexus injury underwent reconstruction by double free muscle transfer (DFMT, 47 cases), single muscle transfer (SMT, 16 cases) or nerve transfers (NT, 18 cases). They were evaluated for functional outcome and quality of life (QoL) using the Disability of Arm, Shoulder and Hand questionnaire, both pre- and post-operatively. The three groups were compared and followed-up for at least 24 months. The mean shoulder abduction and flexion were comparable in all groups, but external rotation was significantly better in the DFMT group as were range and quantitative power of elbow flexion. Patients who had undergone DFMT had reasonable total active finger movement and hook grip strength. All groups showed improvement in function at a level greater than a minimum clinically important difference. The DFMT group showed the greatest improvement. Patients in the DFMT group had a better functional outcome and QoL recovery than those in the NT and SMT groups. Double free muscle transfer procedure is capable of restoring maximum function in patients of total brachial plexus palsy. ©2016 The British Editorial Society of Bone & Joint Surgery.

  8. A comparative study of all-vanadium and iron-chromium redox flow batteries for large-scale energy storage

    Science.gov (United States)

    Zeng, Y. K.; Zhao, T. S.; An, L.; Zhou, X. L.; Wei, L.

    2015-12-01

    The promise of redox flow batteries (RFBs) utilizing soluble redox couples, such as all vanadium ions as well as iron and chromium ions, is becoming increasingly recognized for large-scale energy storage of renewables such as wind and solar, owing to their unique advantages including scalability, intrinsic safety, and long cycle life. An ongoing question associated with these two RFBs is determining whether the vanadium redox flow battery (VRFB) or iron-chromium redox flow battery (ICRFB) is more suitable and competitive for large-scale energy storage. To address this concern, a comparative study has been conducted for the two types of battery based on their charge-discharge performance, cycle performance, and capital cost. It is found that: i) the two batteries have similar energy efficiencies at high current densities; ii) the ICRFB exhibits a higher capacity decay rate than does the VRFB; and iii) the ICRFB is much less expensive in capital costs when operated at high power densities or at large capacities.

  9. COMPARATIVE STUDY OF THREE LINEAR SYSTEM SOLVER APPLIED TO FAST DECOUPLED LOAD FLOW METHOD FOR CONTINGENCY ANALYSIS

    Directory of Open Access Journals (Sweden)

    Syafii

    2017-03-01

    Full Text Available This paper presents the assessment of fast decoupled load flow computation using three linear system solver scheme. The full matrix version of the fast decoupled load flow based on XB methods used in this study. The numerical investigations are carried out on the small and large test systems. The execution time of small system such as IEEE 14, 30, and 57 are very fast, therefore the computation time can not be compared for these cases. Another cases IEEE 118, 300 and TNB 664 produced significant execution speedup. The superLU factorization sparse matrix solver has best performance and speedup of load flow solution as well as in contigency analysis. The invers full matrix solver can solved only for IEEE 118 bus test system in 3.715 second and for another cases take too long time. However for superLU factorization linear solver can solved all of test system in 7.832 second for a largest of test system. Therefore the superLU factorization linear solver can be a viable alternative applied in contingency analysis.

  10. Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard

    DEFF Research Database (Denmark)

    Hansen, Susan; Dahl, Ronald; Hoffmann, Hans Jürgen

    2008-01-01

    at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte...... concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (p...LeukoGating can be established using microscopy as a reference, and is comparable to BT chamber and SPT determination. Leukocyte concentrations can be measured with CVA on flow cytometers in research and clinical settings....

  11. On groundwater flow modelling in safety analyses of spent fuel disposal. A comparative study with emphasis on boundary conditions

    Energy Technology Data Exchange (ETDEWEB)

    Jussila, P

    1999-11-01

    Modelling groundwater flow is an essential part of the safety assessment of spent fuel disposal because moving groundwater makes a physical connection between a geological repository and the biosphere. Some of the common approaches to model groundwater flow in bedrock are equivalent porous continuum (EC), stochastic continuum and various fracture network concepts. The actual flow system is complex and measuring data are limited. Multiple distinct approaches and models, alternative scenarios as well as calibration and sensitivity analyses are used to give confidence on the results of the calculations. The correctness and orders of magnitude of results of such complex research can be assessed by comparing them to the results of simplified and robust approaches. The first part of this study is a survey of the objects, contents and methods of the groundwater flow modelling performed in the safety assessment of the spent fuel disposal in Finland and Sweden. The most apparent difference of the Swedish studies compared to the Finnish ones is the approach of using more different models, which is enabled by the more resources available in Sweden. The results of more comprehensive approaches provided by international co-operation are very useful to give perspective to the results obtained in Finland. In the second part of this study, the influence of boundary conditions on the flow fields of a simple 2D model is examined. The assumptions and simplifications in this approach include e.g. the following: (1) the EC model is used, in which the 2-dimensional domain is considered a continuum of equivalent properties without fractures present, (2) the calculations are done for stationary fields, without sources or sinks present in the domain and with a constant density of the groundwater, (3) the repository is represented by an isotropic plate, the hydraulic conductivity of which is given fictitious values, (4) the hydraulic conductivity of rock is supposed to have an exponential

  12. Comparative, validity and responsiveness of the HOOS-PS and KOOS-PS to the WOMAC physical function subscale in total joint replacement for osteoarthritis

    DEFF Research Database (Denmark)

    Davis, A M; Perruccio, A V; Canizares, M

    2009-01-01

    OBJECTIVE: To evaluate the internal consistency of the Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS) and the Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS) in total hip replacement (THR) and total knee (TKR) replacement....... Construct validity and responsiveness were compared to the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) Likert 3.0 physical function (PF) subscale and the PF excluding the items in the short measures (PF-exclusions). METHODS: Participants completed the full HOOS or KOOS, measures...... of fatigue, anxiety, depression and the Chronic Pain Grade (CPG) pre-surgery and the HOOS or KOOS 6 months post-surgery. Internal consistency for the HOOS-PS and KOOS-PS was calculated using Cronbach's alpha. For construct validity, it was hypothesized that correlations between the HOOS-PS or KOOS-PS and PF...

  13. Diagnostic value of quantitative stenosis predictors with coronary CT angiography compared to invasive fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Renker, Matthias [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Kerckhoff Heart and Thorax Center, Benekestrasse 2-8, 61231 Bad Nauheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Wichmann, Julian L. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Fuller, Stephen R.; Rier, Jeremy D.; Bayer, Richard R.; Steinberg, Daniel H. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); De Cecco, Carlo N. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Departments of Radiological Sciences, Oncology, and Pathology, University of Rome “Sapienza”-Polo Pontino, Latina, Viale Regina Elena, 324-00161 Roma (Italy); Baumann, Stefan [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); First Department of Medicine, University Medical Centre Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2015-08-15

    Highlights: • Evaluation of the diagnostic performance of CCTA predictors for coronary stenosis. • TAG was unable to detect hemodynamically significant coronary lesions. • CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA. • CT-FFR was the best parameter. - Abstract: Objective: To evaluate the diagnostic performance of CCTA-derived stenosis predictors including CT-FFR for the detection of ischemia-inducing stenosis compared to invasive FFR. Materials and methods: Stenosis parameters were assessed using dual-source CT (DSCT). All patients underwent both CCTA and invasive FFR within 3 months and were retrospectively analyzed. Observers visually assessed all CCTA studies and performed multiple lesion measurements. Lesion length/minimal luminal diameter{sup 4} (LL/MLD{sup 4}), transluminal attenuation gradient (TAG), corrected coronary attenuation (CCO) and CT-FFR were calculated. Results: The cohort included 32 patients (58 ± 12 years, 66%male). Among 32 coronary lesions, 8 (25%) were considered hemodynamically significant with an FFR <0.80. Compared to invasive FFR, the per-vessel sensitivity and specificity of CCTA, CT-FFR, LL/MLD{sup 4}, CCO and TAG for detecting hemodynamically significant lesions were 100% and 54%, 100% and 91%, 85% and 92%, 66% and 88%, 37% and 58%, respectively. Receiver operating characteristics analysis resulted in an area under the curve of 0.91 for CT-FFR (p = 0.0005), 0.88 for LL/MLD{sup 4} (p < 0.0001), 0.85 for CCO (p < 0.0001). TAG with an AUC of 0.67 (p = 0.152) was unable to discriminate between vessels with or without hemodynamically significant lesions. Conclusion: CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA analysis alone for discrimination of hemodynamically significant coronary stenosis.

  14. Comparing the Performance of Artificial Intelligence Models in Estimating Water Quality Parameters in Periods of Low and High Water Flow

    Directory of Open Access Journals (Sweden)

    majid montaseri

    2017-03-01

    Full Text Available Introduction: A total dissolved solid (TDS is an important indicator for water quality assesment. Since the composition of mineral salts and discharge affects the TDS of water, it is important to understand the relationships of mineral salts composition with TDS. Materials and Methods: In this study, methods of artificial neural networks with five different training algorithm,Levenberg-Marquardt (LM, Scaled Conjugate Gradient (SCG, Fletcher Conjugate Gradient (CGF, One Step Secant (OSS and Gradient descent with adaptive learning rate backpropagation(GDAalgorithm and adaptive Neurofuzzy inference system based on Subtractive Clustering were used to model water quality properties of Zarrineh River Basin, to be developed in total dissolved solids prediction. ANN and ANFIS program code were written in MATLAB language. Here, the ANN with one hidden layer was used and the hidden nodes’ number was determined using trial and error. Different activation functions (logarithm sigmoid, tangent sigmoid and linear were tried for the hidden and output nodes. Therefore, water quality data from seven hydrometer stationswere used during the statistical period of 18years (1993-2010.In this research, the study period was divided into two periods of dry and wet flow, and then in a preliminary statistical analysis, the main parameters affecting the estimation of the TDS are determined and isused for modeling. 75% of data are used for remaining and 25% of the data are used for evaluation of the model, randomly. In this paper, three statistical evaluation criteria, correlation coefficient (R, the root mean square error (RMSE and mean absolute error (MAE were used to assess models’ performances. Results and Discussion: By applying correlation coefficients method between the parameters of water quality and discharge with total dissolved solid in two periods, wet and dry periods, the significant (at 95% level variables entered into the model were Q, HCO3., Cl, So4, Ca

  15. Five-year results of a randomized clinical trial comparing total mastectomy and segmental mastectomy with or without radiation in the treatment of breast cancer

    International Nuclear Information System (INIS)

    Fisher, B.; Bauer, M.; Margolese, R.

    1985-01-01

    In 1976 the authors began a randomized trial to evaluate breast conservation by a segmental mastectomy in the treatment of State I and II breast tumors less than or equal to 4 cm in size. The operation removes only sufficient tissue to ensure that margins of resected specimens are free of tumor. Women were randomly assigned to total mastectomy, segmental mastectomy alone, or segmental mastectomy followed by breast irradiation. All patients had auxillary dissections, and patients with positive nodes received chemotherapy. Life-tables estimates based on data from 1843 women indicated that treatment by segmental mastectomy, with or without breast irradiation, resulted in disease-free, distant-disease-free, and overall survival at five years that was no worse than that after total breast removal. In fact, disease-free survival after segmental mastectomy plus radiation was better than disease-free survival after total mastectomy, and overall survival after segmental mastectomy, with or without radiation, was better than overall survival after total mastectomy. A total of 92.3% of women treated with radiation remained free of breast tumor at five years, as compared with 72.1% of those receiving no radiation. Among patients with positive nodes 97.9% of women treated with radiation and 63.8% of those receiving no radiation remained tumor-free, although both groups received chemotherapy. They conclude that segmental mastectomy, followed by breast irradiation in all patients and adjuvant chemotherapy in women with positive nodes, is appropriate therapy for Stage I and II breast tumors less than or equal to 4 cm, provided that margins of resected specimens are free of tumor. 23 references, 4 figures, 6 tables

  16. Autologous Stem Cell Transplantation in Patients With Multiple Myeloma: An Activity-based Costing Analysis, Comparing a Total Inpatient Model Versus an Early Discharge Model.

    Science.gov (United States)

    Martino, Massimo; Console, Giuseppe; Russo, Letteria; Meliado', Antonella; Meliambro, Nicola; Moscato, Tiziana; Irrera, Giuseppe; Messina, Giuseppe; Pontari, Antonella; Morabito, Fortunato

    2017-08-01

    Activity-based costing (ABC) was developed and advocated as a means of overcoming the systematic distortions of traditional cost accounting. We calculated the cost of high-dose chemotherapy and autologous stem cell transplantation (ASCT) in patients with multiple myeloma using the ABC method, through 2 different care models: the total inpatient model (TIM) and the early-discharge outpatient model (EDOM) and compared this with the approved diagnosis related-groups (DRG) Italian tariffs. The TIM and EDOM models involved a total cost of €28,615.15 and €16,499.43, respectively. In the TIM model, the phase with the greatest economic impact was the posttransplant (recovery and hematologic engraftment) with 36.4% of the total cost, whereas in the EDOM model, the phase with the greatest economic impact was the pretransplant (chemo-mobilization, apheresis procedure, cryopreservation, and storage) phase, with 60.4% of total expenses. In an analysis of each episode, the TIM model comprised a higher absorption than the EDOM. In particular, the posttransplant represented 36.4% of the total costs in the TIM and 17.7% in EDOM model, respectively. The estimated reduction in cost per patient using an EDOM model was over €12,115.72. The repayment of the DRG in Calabrian Region for the ASCT procedure is €59,806. Given the real cost of the transplant, the estimated cost saving per patient is €31,190.85 in the TIM model and €43,306.57 in the EDOM model. In conclusion, the actual repayment of the DRG does not correspond to the real cost of the ASCT procedure in Italy. Moreover, using the EDOM, the cost of ASCT is approximately the half of the TIM model. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    James M. Economides

    2017-03-01

    Full Text Available BackgroundIn cases of total knee arthroplasty (TKA threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA.MethodsA systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis.ResultsA total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05 and limb salvage (89.8% vs. 100%, P=0.14 were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78, the rates of persistent infection (16.4% vs. 0%, P=0.14 and recurrent infection (9.1% vs. 4%, P=0.94 tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported.ConclusionsRates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

  18. Comparative study on the influence of depth, number and arrangement of dimples on the flow and heat transfer characteristics at turbulent flow regimes

    Science.gov (United States)

    Nazari, Saeed; Zamani, Mahdi; Moshizi, Sajad A.

    2018-03-01

    The ensuing study is dedicated to a series of numerical investigations concerning the effects of various geometric parameters of dimpled plates on the flow structure and heat transfer performance in a rectangular duct compared to the smooth plate. These parameters are the arrangement, number and depth of dimples. Two widely used staggered and square patterns in addition to a triangular arrangement, and three dimple depths (Δ = δ/d = 0.25, 0.375 and 0.5) have been chosen for this particular study. All studies have been conducted at three different Reynolds numbers Re = 25,000, 50,000 and 100,000. In order to capture the flow structures in the vicinity of dimples and contributing phenomena related to the boundary layer interactions, fully structured grids with y+ < 1 have been generated for all the cases. The realizable k t -ɛ two-layer model was selected as a proper turbulent model. It can be observed from the obtained results that higher effective area for heat transfer and a myriad of turbulent vortices mixing the hot fluid near the surface with the passing cold fluid generated from the downwind rims of dimples are the causes for improved average Nusselt number in the dimpled surface in comparison to the smooth plate. However, more pressure loss due to the higher friction drag and recirculation zones inside dimples will exist as a drawback in this system. Moreover, for all arrangements increasing dimple ratio Δ has a negative impact on the heat transfer augmentation and also deteriorates the pressure loss, which leads to this fact that Δ = 0.25 serves as the best option for the dimple depth.

  19. Postoperative Quality of Life after Total Gastrectomy Compared with Partial Gastrectomy: Longitudinal Evaluation by European Organization for Research and Treatment of Cancer-OG25 and STO22.

    Science.gov (United States)

    Lee, Jeong-Hwan; Lee, Hyuk-Joon; Choi, Yun Suk; Kim, Tae Han; Huh, Yeon-Ju; Suh, Yun-Suhk; Kong, Seong-Ho; Yang, Han-Kwang

    2016-12-01

    The European Organization for Research and Treatment of Cancer quality-of-life questionnaire-OG25 was developed to evaluate the quality of life in patients with stomach and esophageal cancer. The following are included in the OG25 but not in the STO22: odynophagia, choked when swallowing, weight loss, trouble eating with others, trouble swallowing saliva, trouble talking, and trouble with coughing. In this study, we evaluated the quality of life of gastrectomized patients using both, the OG25 and the STO22. A total of 138 patients with partial gastrectomy (PG) (distal gastrectomy=91; pylorus-preserving gastrectomy= 47) and 44 patients with total gastrectomy (TG) were prospectively evaluated. Body weight and scores from the OG25 and STO22 were evaluated preoperatively and at 3 weeks, 3 months, and 6 months after surgery. Patients with TG had significant weight loss compared to patients with PG. At 3 months, TG was associated with worse scores for dysphagia, eating, odynophagia, trouble eating with others, trouble with taste, and weight loss on the OG25. TG was also associated with dysphagia, eating restrictions, and anxiety on the STO22. The OG25 helped differentiate between the groups with respect to weight loss, odynophagia, choked when swallowing, and trouble eating with others. The OG25 scores changed over time and were significantly different. The OG25 is a more sensitive and useful scale than the STO22 for evaluating the quality of life of gastrectomized patients, especially those with total gastrectomy.

  20. Comparative evaluation of serum and salivary immunoglobulin G and A levels with total serum protein in oral submucous fibrosis patients: A case control study

    Directory of Open Access Journals (Sweden)

    M Kandasamy

    2016-01-01

    Full Text Available Aim and Objective: The objective of this study is to estimate and compare the serum and salivary immunoglobulin G and A (IgG, IgA levels in various stages of oral submucous fibrosis (OSMF patients and relate it to total serum protein (TSP and hemoglobin (Hb levels. Materials and Methods: The sample for the present study comprised a total of 20 healthy controls, 20 OSMF patients. About 5 ml of blood and 2 ml of saliva were collected. Quantitative analysis of serum and salivary IgG, IgA was done by turbidometric immunoassay. TSP and Hb were estimated by Biuret and cyanmethemoglobin methods, respectively. Results: Serum and salivary IgA and IgG levels were statistically significantly increased (P < 0.001 in OSMF patients when compared to controls. Also serum and salivary IgG and IgA levels showed significantly increased (P < 0.01 in all the three staging of OSMF when compared to control group. Hb levels and TSP levels were significantly decreased (P < 0.001 in OSMF patients when compared to controls. One-way ANOVA, Pearson's correlation, and unpaired t -test were used for statistical analysis. Conclusion: The elevated levels of IgG and IgA are also in favor of polygammapathy, which are nonspecific and nondiagnostic objective reflections of an underlying disease. Decreased TSP is a result of host response and Hb, acts as an indicator of nutritional status plays an important role. It is also observed from the present study that the severity of OSMF was directly proportional to the estimated elevated levels of the major IgG and IgA. A need is also felt for the knowledge of immunoprofile estimation in etiology and pathogenesis that would prove a great asset in the proper assessment of this condition.

  1. Comparative evaluation of serum and salivary immunoglobulin G and A levels with total serum protein in oral submucous fibrosis patients: A case control study.

    Science.gov (United States)

    Kandasamy, M; Jaisanghar, N; Austin, Ravi David; Srivastava, Kumar Chandan; Anusuya, G Sai; Anisa, N

    2016-10-01

    The objective of this study is to estimate and compare the serum and salivary immunoglobulin G and A (IgG, IgA) levels in various stages of oral submucous fibrosis (OSMF) patients and relate it to total serum protein (TSP) and hemoglobin (Hb) levels. The sample for the present study comprised a total of 20 healthy controls, 20 OSMF patients. About 5 ml of blood and 2 ml of saliva were collected. Quantitative analysis of serum and salivary IgG, IgA was done by turbidometric immunoassay. TSP and Hb were estimated by Biuret and cyanmethemoglobin methods, respectively. Serum and salivary IgA and IgG levels were statistically significantly increased ( P < 0.001) in OSMF patients when compared to controls. Also serum and salivary IgG and IgA levels showed significantly increased ( P < 0.01) in all the three staging of OSMF when compared to control group. Hb levels and TSP levels were significantly decreased ( P < 0.001) in OSMF patients when compared to controls. One-way ANOVA, Pearson's correlation, and unpaired t -test were used for statistical analysis. The elevated levels of IgG and IgA are also in favor of polygammapathy, which are nonspecific and nondiagnostic objective reflections of an underlying disease. Decreased TSP is a result of host response and Hb, acts as an indicator of nutritional status plays an important role. It is also observed from the present study that the severity of OSMF was directly proportional to the estimated elevated levels of the major IgG and IgA. A need is also felt for the knowledge of immunoprofile estimation in etiology and pathogenesis that would prove a great asset in the proper assessment of this condition.

  2. Sequential Determination of Total Arsenic and Cadmium in Concentrated Cadmium Sulphate Solutions by Flow-Through Stripping Chronopotentiometry after Online Cation Exchanger Separation

    Directory of Open Access Journals (Sweden)

    Frantisek Cacho

    2012-01-01

    Full Text Available Flow-through stripping chronopotentiometry with a gold wire electrode was used for the determination of total arsenic and cadmium in cadmium sulphate solutions for cadmium production. The analysis is based on the online separation of arsenic as arsenate anion from cadmium cations by means of a cation exchanger. On measuring arsenate in the effluent, the trapped cadmium is eluted by sodium chloride solution and determined in a small segment of the effluent by making use of the same electrode. The elaborated protocol enables a full automatic measurement of both species in the same sample solution. The accuracy of the results was confirmed by atomic absorption spectrometry. The LOD and LOQ for Arsenic were found to be 0.9 μg dm-3 and 2.7 μg dm-3, respectively. A linear response range was observed in the concentration range of 1 to 300 μg dm-3 for sample volumes of 4 mL. The repeatability and reproducibility were found to be 2.9% and 5.2%, respectively. The linear response range for cadmium was found to be 0.5 to 60 g/L. The method was tested on samples from a cadmium production plant.

  3. Iterated greedy algorithms to minimize the total family flow time for job-shop scheduling with job families and sequence-dependent set-ups

    Science.gov (United States)

    Kim, Ji-Su; Park, Jung-Hyeon; Lee, Dong-Ho

    2017-10-01

    This study addresses a variant of job-shop scheduling in which jobs are grouped into job families, but they are processed individually. The problem can be found in various industrial systems, especially in reprocessing shops of remanufacturing systems. If the reprocessing shop is a job-shop type and has the component-matching requirements, it can be regarded as a job shop with job families since the components of a product constitute a job family. In particular, sequence-dependent set-ups in which set-up time depends on the job just completed and the next job to be processed are also considered. The objective is to minimize the total family flow time, i.e. the maximum among the completion times of the jobs within a job family. A mixed-integer programming model is developed and two iterated greedy algorithms with different local search methods are proposed. Computational experiments were conducted on modified benchmark instances and the results are reported.

  4. Cell biological effects of total body irradiation on growth and differentiation of acute myelogenous leukemia cells compared to normal bone marrow

    Energy Technology Data Exchange (ETDEWEB)

    Greenberger, J S; Weichselbaum, R R; Botnick, L E; Sakakeeny, M; Moloney, W C

    1979-01-01

    Radiation therapy is used as total body treatment in preparation of the acute myelogenous leukemia (AML) patient for bone marrow transplantation. Many AML patients will have residual leukemia cells at the time of total body irradiation (TBI). In the present study, the effect of TBI on leukemic myeloid cells was compared to the effect on normal marrow granulocytic stem cells (CFUc) in vitro. Little difference from that of normal CFUc was found in the radiosensitivity of two mouse myeloid leukemia cell lines. The effect of TBI on growth of WEHI-3 or J774 cells in millipore diffusion chambers was stimulatory. These AML cell lines as well as others derived from Friend or Abelson virus infected in vitro long term mouse marrow cultures showed some morphologic differentiation by 7 days growth in diffusion chambers in irradiated heterologous rat hosts, but immature cells predominated by day 21. Thus, evidence in murine models of AML indicates that residual AML cells surviving chemotherapy will show no greater susceptibility to radiation killing compared to normal stem cells and will rapidly repopulate the irradiated host.

  5. A comparative study of Cu, Ag and Au doped CeO{sub 2} in the total oxidation of volatile organic compounds (VOCs)

    Energy Technology Data Exchange (ETDEWEB)

    Aboukaïs, Antoine, E-mail: aboukais@univ-littoral.fr [Unité de Chimie Environnementale et Interactions sur le Vivant EA 4492, ULCO, Equipe de Catalyse-UCEIV, MREI, 59140, Dunkerque (France); Skaf, Mira, E-mail: miraskaf@hotmail.com [Unité de Chimie Environnementale et Interactions sur le Vivant EA 4492, ULCO, Equipe de Catalyse-UCEIV, MREI, 59140, Dunkerque (France); Department of Chemistry, Faculty of Sciences, University of Balamand, P.O. Box 100, Deir El Balamand, Kelhat-Tripoli (Lebanon); Hany, Sara, E-mail: sarahani@hotmail.com [Unité de Chimie Environnementale et Interactions sur le Vivant EA 4492, ULCO, Equipe de Catalyse-UCEIV, MREI, 59140, Dunkerque (France); Cousin, Renaud, E-mail: Renaud.Cousin@univ-littoral.fr [Unité de Chimie Environnementale et Interactions sur le Vivant EA 4492, ULCO, Equipe de Catalyse-UCEIV, MREI, 59140, Dunkerque (France); Aouad, Samer, E-mail: Samer.Aouad@balamand.edu.lb [Department of Chemistry, Faculty of Sciences, University of Balamand, P.O. Box 100, Deir El Balamand, Kelhat-Tripoli (Lebanon); Labaki, Madona, E-mail: mlabaki@ul.edu.lb [Laboratory of Physical Chemistry of Materials (LCPM)/PR2N, Faculty of Sciences, Lebanese University, Fanar, PO Box 90656, Jdeidet El Metn (Lebanon); Abi-Aad, Edmond, E-mail: abiaad@univ-littoral.fr [Unité de Chimie Environnementale et Interactions sur le Vivant EA 4492, ULCO, Equipe de Catalyse-UCEIV, MREI, 59140, Dunkerque (France)

    2016-07-01

    Total oxidation of two Volatile Organic Compounds (VOCs), propylene and toluene, was investigated over M/CeO{sub 2} catalysts, where M is a metal from IB group (i.e. Au, Ag, Cu), prepared by two different methods: the conventional wet impregnation and the deposition-precipitation. The catalysts have been characterized by means of total surface area (BET), X-ray diffraction (XRD), electron paramagnetic resonance (EPR), X-ray photoelectron spectroscopy (XPS), diffuse reflectance ultra-violet-visible spectroscopy (DR-UV/Vis), and temperature-programmed reduction (TPR), in order to explain the differences observed in their catalytic activity towards the studied reactions. By comparing the two different preparation methods, the presence of metal in high oxidation state for gold and silver, and the presence of clusters for copper were the main factors responsible for the high catalytic activity. This latter was also found to be related, when comparing the different IB metals, to the values of the oxidation/reduction potential of the redox couples of the different metals. - Highlights: • IB metals (Au, Ag and Cu) were supported on ceria (CeO{sub 2}) by two different methods. • The solids were tested as catalysts for total oxidation of propylene and toluene. • The deposition-precipitation is better for Au whereas for Ag and Cu it is the impregnation. • High oxidation states of gold and silver and clusters of copper enhanced catalytic behavior. • Catalytic activity is linked to the oxidation/reduction potential of the redox IB couples.

  6. A comparative study of Cu, Ag and Au doped CeO_2 in the total oxidation of volatile organic compounds (VOCs)

    International Nuclear Information System (INIS)

    Aboukaïs, Antoine; Skaf, Mira; Hany, Sara; Cousin, Renaud; Aouad, Samer; Labaki, Madona; Abi-Aad, Edmond

    2016-01-01

    Total oxidation of two Volatile Organic Compounds (VOCs), propylene and toluene, was investigated over M/CeO_2 catalysts, where M is a metal from IB group (i.e. Au, Ag, Cu), prepared by two different methods: the conventional wet impregnation and the deposition-precipitation. The catalysts have been characterized by means of total surface area (BET), X-ray diffraction (XRD), electron paramagnetic resonance (EPR), X-ray photoelectron spectroscopy (XPS), diffuse reflectance ultra-violet-visible spectroscopy (DR-UV/Vis), and temperature-programmed reduction (TPR), in order to explain the differences observed in their catalytic activity towards the studied reactions. By comparing the two different preparation methods, the presence of metal in high oxidation state for gold and silver, and the presence of clusters for copper were the main factors responsible for the high catalytic activity. This latter was also found to be related, when comparing the different IB metals, to the values of the oxidation/reduction potential of the redox couples of the different metals. - Highlights: • IB metals (Au, Ag and Cu) were supported on ceria (CeO_2) by two different methods. • The solids were tested as catalysts for total oxidation of propylene and toluene. • The deposition-precipitation is better for Au whereas for Ag and Cu it is the impregnation. • High oxidation states of gold and silver and clusters of copper enhanced catalytic behavior. • Catalytic activity is linked to the oxidation/reduction potential of the redox IB couples.

  7. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sigrist, Mirna, E-mail: msigrist@fiq.unl.edu.ar [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Albertengo, Antonela; Beldomenico, Horacio [Laboratorio Central, Facultad de Ingenieria Quimica, Universidad Nacional del Litoral, Santiago del Estero 2654-Piso 6, (3000) Santa Fe (Argentina); Tudino, Mabel [Laboratorio de Analisis de Trazas, Departamento de Quimica Inorganica, Analitica y Quimica Fisica/INQUIMAE, Facultad de Ciencias Exactas y Naturales, Pabellon II, Ciudad Universitaria (1428), Buenos Aires (Argentina)

    2011-04-15

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH{sub 3} generation using 3.5 mol L{sup -1} HCl as carrier solution and 0.35% (m/v) NaBH{sub 4} in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, HPO{sub 4}{sup 2-}, HCO{sub 3}{sup -} on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C{sub 6}H{sub 8}O{sub 6} solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 {mu}g L{sup -1} and 0.6 {mu}g L{sup -1} for As(III) and inorganic total As, respectively, were obtained for a 500 {mu}L sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h{sup -1}. The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species

  8. Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sigrist, Mirna; Albertengo, Antonela; Beldomenico, Horacio; Tudino, Mabel

    2011-01-01

    A simple and robust on-line sequential injection system based on solid phase extraction (SPE) coupled to a flow injection hydride generation atomic absorption spectrometer (FI-HGAAS) with a heated quartz tube atomizer (QTA) was developed and optimized for the determination of As(III) in groundwater without any kind of sample pretreatment. The method was based on the selective retention of inorganic As(V) that was carried out by passing the filtered original sample through a cartridge containing a chloride-form strong anion exchanger. Thus the most toxic form, inorganic As(III), was determined fast and directly by AsH 3 generation using 3.5 mol L -1 HCl as carrier solution and 0.35% (m/v) NaBH 4 in 0.025% NaOH as the reductant. Since the uptake of As(V) should be interfered by several anions of natural occurrence in waters, the effect of Cl - , SO 4 2- , NO 3 - , HPO 4 2- , HCO 3 - on retention was evaluated and discussed. The total soluble inorganic arsenic concentration was determined on aliquots of filtered samples acidified with concentrated HCl and pre-reduced with 5% KI-5% C 6 H 8 O 6 solution. The concentration of As(V) was calculated by difference between the total soluble inorganic arsenic and As(III) concentrations. Detection limits (LODs) of 0.5 μg L -1 and 0.6 μg L -1 for As(III) and inorganic total As, respectively, were obtained for a 500 μL sample volume. The obtained limits of detection allowed testing the water quality according to the national and international regulations. The analytical recovery for water samples spiked with As(III) ranged between 98% and 106%. The sampling throughput for As(III) determination was 60 samples h -1 . The device for groundwater sampling was especially designed for the authors. Metallic components were avoided and the contact between the sample and the atmospheric oxygen was carried to a minimum. On-field arsenic species separation was performed through the employ of a serial connection of membrane filters and

  9. Quality of life in patients after total pancreatectomy is comparable with quality of life in patients who undergo a partial pancreatic resection.

    Science.gov (United States)

    Epelboym, Irene; Winner, Megan; DiNorcia, Joseph; Lee, Minna K; Lee, James A; Schrope, Beth; Chabot, John A; Allendorf, John D

    2014-03-01

    Quality of life after total pancreatectomy (TP) is perceived to be poor secondary to insulin-dependent diabetes and pancreatic insufficiency. As a result, surgeons may be reluctant to offer TP for benign and premalignant pancreatic diseases. We retrospectively reviewed presenting features, operative characteristics, and postoperative outcomes of all patients who underwent TP at our institution. Quality of life was assessed using institutional questionnaires and validated general, pancreatic disease-related, and diabetes-related instruments (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire [EORTC QLQ-C30 and module EORTC-PAN26], Audit of Diabetes Dependent Quality of Life), and compared with frequency-matched controls, patients after a pancreaticoduodenectomy (PD). Continuous variables were compared using Student t-test or analysis of variance. Categorical variables were compared using χ(2) or Fisher exact test. Between 1994 and 2011, 77 TPs were performed. Overall morbidity was 49%, but only 15.8% patients experienced a major complication. Perioperative mortality was 2.6%. Comparing 17 TP and 14 PD patients who returned surveys, there were no statistically significant differences in quality of life in global health, functional status, or symptom domains of EORTC QLQ-C30 or in pancreatic disease-specific EORTC-PAN26. TP patients had slightly but not significantly higher incidence of hypoglycemic events as compared with PD patients with postoperative diabetes. A negative impact of diabetes assessed by Audit of Diabetes Dependent Quality of Life did not differ between TP and PD. Life domains most negatively impacted by diabetes involved travel and physical activity, whereas self-confidence, friendships and personal relationships, motivation, and feelings about the future remained unaffected. Although TP-induced diabetes negatively impacts select activities and functions, overall quality of life is comparable with that of

  10. Effectiveness of team nursing compared with total patient care on staff wellbeing when organizing nursing work in acute care wards: a systematic review.

    Science.gov (United States)

    King, Allana; Long, Lesley; Lisy, Karolina

    2015-11-01

    The organization of the work of nurses, according to recognized models of care, can have a significant impact on the wellbeing and performance of nurses and nursing teams. This review focuses on two models of nursing care delivery, namely, team and total patient care, and their effect on nurses' wellbeing. To examine the effectiveness of team nursing compared to total patient care on staff wellbeing when organizing nursing work in acute care wards. Participants were nurses working on wards in acute care hospitals.The intervention was the use of a team nursing model when organizing nursing work. The comparator was the use of a total patient care model.This review considered quantitative study designs for inclusion in the review.The outcome of interest was staff wellbeing which was measured by staff outcomes in relation to job satisfaction, turnover, absenteeism, stress levels and burnout. The search strategy aimed to find both published and unpublished studies from 1995 to April 21, 2014. Quantitative papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments from the Joanna Briggs Institute. Data was extracted from papers included in the review using the standardized data extraction tool from the Joanna Briggs Institute. The data extracted included specific details about the interventions, populations, study methods and outcomes of significance to the review question and its specific objectives. Due to the heterogeneity of the included quantitative studies, meta-analysis was not possible. Results have been presented in a narrative form. The database search returned 10,067 records. Forty-three full text titles were assessed, and of these 40 were excluded, resulting in three studies being included in the review. Two of the studies were quasi experimental designs and the other was considered an uncontrolled before and after experimental study

  11. Comparative analysis of three different of extraction protocols of total nucleic acids of squash (Cucurbita moschata) for the diagnosis from geminivirus

    International Nuclear Information System (INIS)

    Hernandez Jimenez, Eduardo

    2008-01-01

    The geminivirus constitute an important group of plant pathogens, characterized by an unusual morphology of the viral particle and its DNA. They have a paired icosahedral cover and a small circular genome of DNA simple band that is replicated, by DNA double band, in the nucleus of the infected cell of the plant. Many researchers have focused on the development and optimization of protocols for obtaining DNA or RNA of interest, because of rapid advances in molecular biology during the second half of the XX century and the beginning of XXI century, and to that the extraction and purification of nucleic acids is the first step mainly of the procedures in this area. The objective is to compare, by means of molecular techniques, the DNA purification in squash from different ways of storage and extraction protocols of total nucleic acids of the plant, in order to improve the quality and amount of genetic matters whereupon the detection and characterization of geminivirus are realised. Three methods were compared: i. Dellaporta and collaborators (1983), ii.- Doyle and Doyle (1990) and iii.- Jose and Usha (2000). The operation of the three methods scaled downward (15 milligrams of leaf tissue) and two ways of storage were evaluated: 1.- tubes with silica gel (SG, a desiccant) and 2.- frozen to -70 degrees Celsius. The method of Jose and Usha (2000) presented technical difficulties that not permitted to scale downward, for which it should work with the purification from a gram of foliar tissue. The integrity of the total DNA was verified superior in the material stored to -70 degrees celsius for all the methods, by means of electrophoresis in gels of agarose, besides that the protocol of Dellaporta et al. (1983) tends to enrich the RNA. The readings were similar for the methods of Dellaporta et al. (1983) and Doyle and Doyle (1993), this was evidenced upon quantifying the total DNA and that is extracted at least a 30% more of DNA from material in the desiccant with respect

  12. Intercomparison of the comparative reactivity method (CRM) and pump-probe technique for measuring total OH reactivity in an urban environment

    Science.gov (United States)

    Hansen, R. F.; Blocquet, M.; Schoemaecker, C.; Léonardis, T.; Locoge, N.; Fittschen, C.; Hanoune, B.; Stevens, P. S.; Sinha, V.; Dusanter, S.

    2015-10-01

    The investigation of hydroxyl radical (OH) chemistry during intensive field campaigns has led to the development of several techniques dedicated to ambient measurements of total OH reactivity, which is the inverse of the OH lifetime. Three techniques are currently used during field campaigns, including the total OH loss rate method, the pump-probe method, and the comparative reactivity method. However, no formal intercomparison of these techniques has been published so far, and there is a need to ensure that measurements of total OH reactivity are consistent among the different techniques. An intercomparison of two OH reactivity instruments, one based on the comparative reactivity method (CRM) and the other based on the pump-probe method, was performed in October 2012 in a NOx-rich environment, which is known to be challenging for the CRM technique. This study presents an extensive description of the two instruments, the CRM instrument from Mines Douai (MD-CRM) and the pump-probe instrument from the University of Lille (UL-FAGE), and highlights instrumental issues associated with the two techniques. It was found that the CRM instrument used in this study underestimates ambient OH reactivity by approximately 20 % due to the photolysis of volatile organic compounds (VOCs) inside the sampling reactor; this value is dependent on the position of the lamp within the reactor. However, this issue can easily be fixed, and the photolysis of VOCs was successfully reduced to a negligible level after this intercomparison campaign. The UL-FAGE instrument may also underestimate ambient OH reactivity due to the difficulty to accurately measure the instrumental zero. It was found that the measurements are likely biased by approximately 2 s-1, due to impurities in humid zero air. Two weeks of ambient sampling indicate that the measurements performed by the two OH reactivity instruments are in agreement, within the measurement uncertainties for each instrument, for NOx mixing ratios

  13. Comparing the Immediate Effects of a Total Motion Release Warm-up and a Dynamic Warm-up Protocol on the Dominant Shoulder in Baseball Athletes.

    Science.gov (United States)

    Gamma, Stephen C; Baker, Russell; May, James; Seegmiller, Jeff G; Nasypany, Alan; Iorio, Steven M

    2018-04-10

    Gamma, SC, Baker, R, May, J, Seegmiller, JG, Nasypany, A, and Iorio, SM. Comparing the immediate effects of a total motion release warm-up and a dynamic warm-up protocol on the dominant shoulder in baseball athletes. J Strength Cond Res XX(X): 000-000, 2017-A decrease in total range of motion (ROM) of the dominant shoulder may predispose baseball athletes to increased shoulder injury risk; the most effective technique for improving ROM is unknown. The purpose of this study was to compare the immediate effects of Total Motion Release (TMR) to a generic dynamic warm-up program in baseball athletes. Baseball athletes (n = 20) were randomly assigned to an intervention group: TMR group (TMRG; n = 10) or traditional warm-up group (TWG; n = 10). Shoulder ROM measurements were recorded for internal rotation (IR) and external rotation (ER), the intervention was applied, and postmeasurements were recorded. Each group then received the other intervention and postmeasurements were again recorded. The time main effect (p ≤ 0.001) and the time × group interaction effect were significant (p ≤ 0.001) for IR and ER. Post hoc analysis revealed that TMR produced significant increases in mean IR (p ≤ 0.005, d = 1.52) and ER (p ≤ 0.018, d = 1.22) of the dominant shoulder initially. When groups crossed-over, the TMRG experienced a decrease in mean IR and ER after the dynamic warm-up, whereas the TWG experienced a significant increase in mean IR (p ≤ 0.001, d = 3.08) and ER (p ≤ 0.001, d = 2.56) after TMR intervention. Total Motion Release increased IR and ER of the dominant shoulder more than a dynamic warm-up. Dynamic warm-up after TMR also resulted in decreased IR and ER; however, TMR after dynamic warm-up significantly improved IR and ER. Based on these results, TMR is more effective than a generic dynamic warm-up for improving dominant shoulder ROM in baseball players.

  14. Comparative analysis of minimal residual disease detection by multiparameter flow cytometry and enhanced ASO RQ-PCR in multiple myeloma

    International Nuclear Information System (INIS)

    Silvennoinen, R; Lundan, T; Kairisto, V; Pelliniemi, T-T; Putkonen, M; Anttila, P; Huotari, V; Mäntymaa, P; Siitonen, S; Uotila, L; Penttilä, T-L; Juvonen, V; Selander, T; Remes, K

    2014-01-01

    Multiparameter flow cytometry (MFC) and allele-specific oligonucleotide real-time quantitative PCR (ASO RQ-PCR) are the two most sensitive methods to detect minimal residual disease (MRD) in multiple myeloma (MM). We compared these methods in 129 paired post-therapy samples from 22 unselected, consecutive MM patients in complete/near complete remission. Appropriate immunophenotypic and ASO RQ-PCR-MRD targets could be detected and MRD analyses constructed for all patients. The high PCR coverage could be achieved by gradual widening of the primer sets used for clonality detection. In addition, for 13 (55%) of the patients, reverse orientation of the ASO primer and individual design of the TaqMan probe improved the sensitivity and specificity of ASO RQ-PCR analysis. A significant nonlinear correlation prevailed between MFC-MRD and PCR-MRD when both were positive. Discordance between the methods was found in 32 (35%) paired samples, which were negative by MFC-MRD, but positive by ASO RQ-PCR. The findings suggest that with the described technique, ASO RQ-PCR can be constructed for all patients with MM. ASO RQ-PCR is slightly more sensitive in MRD detection than 6−10-color flow cytometry. Owing to technical demands ASO RQ-PCR could be reserved for patients in immunophenotypic remission, especially in efficacy comparisons between different drugs and treatment modalities

  15. Comparative investigation of five nanoparticles in flow of viscous fluid with Joule heating and slip due to rotating disk

    Science.gov (United States)

    Qayyum, Sumaira; Khan, Muhammad Ijaz; Hayat, Tasawar; Alsaedi, Ahmed

    2018-04-01

    Present article addresses the comparative study for flow of five water based nanofluids. Flow in presence of Joule heating is generated by rotating disk with variable thickness. Nanofluids are suspension of Silver (Ag), Copper (Cu), Copper oxide (CuO), Aluminum oxide or Alumina (Al2O3), Titanium oxide or titania (TiO2) and water. Boundary layer approximation is applied to partial differential equations. Using Von Karman transformations the partial differential equations are converted to ordinary differential equations. Convergent series solutions are obtained. Graphical results are presented to examine the behaviors of axial, radial and tangential velocities, temperature, skin friction and Nusselt number. It is observed that radial, axial and tangential velocities decay for slip parameters. Axial velocity decays for larger nanoparticle volume fraction. Effect of nanofluids on velocities dominant than base material. Temperature rises for larger Eckert number and temperature of silver water nanofluid is more because of its higher thermal conductivity. Surface drag force reduces for higher slip parameters. Transfer of heat is more for larger disk thickness index.

  16. SENSITIVITY AND SPECIFICITY OF INDIVIDUAL BERG BALANCE ITEMS COMPARED WITH THE TOTAL SCORE TO PREDICT FALLS IN COMMUNITY DWELLING ELDERLY INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    Hazel Denzil Dias

    2014-09-01

    Full Text Available Background: Falls are a major problem in the elderly leading to increased morbidity and mortality in this population. Scores from objective clinical measures of balance have frequently been associated with falls in older adults. The Berg Balance Score (BBS which is a frequently used scale to test balance impairments in the elderly ,takes time to perform and has been found to have scoring inconsistencies. The purpose was to determine if individual items or a group of BBS items would have better accuracy than the total BBS in classifying community dwelling elderly individuals according to fall history. Method: 60 community dwelling elderly individuals were chosen based on a history of falls in this cross sectional study. Each BBS item was dichotomized at three points along the scoring scale of 0 – 4: between scores of 1 and 2, 2 and 3, and 3 and 4. Sensitivity (Sn, specificity (Sp, and positive (+LR and negative (-LR likelihood ratios were calculated for all items for each scoring dichotomy based on their accuracy in classifying subjects with a history of multiple falls. These findings were compared with the total BBS score where the cut-off score was derived from receiver operating characteristic curve analysis. Results: On analysing a combination of BBS items, B9 and B11 were found to have the best sensitivity and specificity when considered together. However the area under the curve of these items was 0.799 which did not match that of the total score (AUC= 0.837. A, combination of 4 BBS items - B9 B11 B12 and B13 also had good Sn and Sp but the AUC was 0.815. The combination with the AUC closest to that of the total score was a combination items B11 and B13. (AUC= 0.824. hence these two items can be used as the best predictor of falls with a cut off of 6.5 The ROC curve of the Total Berg balance Scale scores revealed a cut off score of 48.5. Conclusion: This study showed that combination of items B11 and B13 may be best predictors of falls in

  17. SENSITIVITY AND SPECIFICITY OF INDIVIDUAL BERG BALANCE ITEMS COMPARED WITH THE TOTAL SCORE TO PREDICT FALLS IN COMMUNITY DWELLING ELDERLY INDIVIDUALS

    Directory of Open Access Journals (Sweden)

    Hazel Denzil Dias

    2014-06-01

    Full Text Available Background: Falls are a major problem in the elderly leading to increased morbidity and mortality in this population. Scores from objective clinical measures of balance have frequently been associated with falls in older adults. The Berg Balance Score (BBS which is a frequently used scale to test balance impairments in the elderly ,takes time to perform and has been found to have scoring inconsistencies. The purpose was to determine if individual items or a group of BBS items would have better accuracy than the total BBS in classifying community dwelling elderly individuals according to fall history. Method: 60 community dwelling elderly individuals were chosen based on a history of falls in this cross sectional study. Each BBS item was dichotomized at three points along the scoring scale of 0 – 4: between scores of 1 and 2, 2 and 3, and 3 and 4. Sensitivity (Sn, specificity (Sp, and positive (+LR and negative (-LR likelihood ratios were calculated for all items for each scoring dichotomy based on their accuracy in classifying subjects with a history of multiple falls. These findings were compared with the total BBS score where the cut-off score was derived from receiver operating characteristic curve analysis. Results: On analysing a combination of BBS items, B9 and B11 were found to have the best sensitivity and specificity when considered together. However the area under the curve of these items was 0.799 which did not match that of the total score (AUC= 0.837. A, combination of 4 BBS items - B9 B11 B12 and B13 also had good Sn and Sp but the AUC was 0.815. The combination with the AUC closest to that of the total score was a combination items B11 and B13. (AUC= 0.824. hence these two items can be used as the best predictor of falls with a cut off of 6.5 The ROC curve of the Total Berg balance Scale scores revealed a cut off score of 48.5. Conclusion: This study showed that combination of items B11 and B13 may be best predictors of falls in

  18. Calibração de modelo para a simulação de vazão e de fósforo total nas sub-bacias dos Rios Conrado e Pinheiro - Pato Branco (PR Model calibration for flow rate and total phosphorous export simulations in the watersheds of the rivers conrado and Pinheiro, Pato Branco (PR

    Directory of Open Access Journals (Sweden)

    Valmir Baltokoski

    2010-02-01

    ção do nutriente ao longo do ano.Hydrological models developed to predict the impacts of non-point source pollution and land use and occupation on water quality have been extremely useful in the study of agricultural systems. For this purpose, the objective of this study was to evaluate the sensitivity of the model SWAT 2005 (Soil and Water Assessment Tool to simulate the flow rate and total phosphorous flow mass. The research was conducted in two contiguous watersheds of the Conrado and Pinheiro rivers, affluents to the Pato Branco river, in Pato Branco and Mariopolis counties, state of Paraná. Climatological data of the period 1979-2006 and observation data of flow rate and total phosphorous export of the years 2004 and 2005 from two weather stations (in the lower part of the main water course of the Conrado and Pinheiro rivers were used. The model requires input data in spatial format of land use and soil data, associated to a digital elevation model (DEM. The AvSWAT-X interface was used with ArcView 3.3® and its extension Spatial Analyst 2.0®, for data input and manipulation. Monthly and yearly averages of flow rate and total phosphorous export were compared to the observed values. The Nash-Sutcliffe Coefficient (COE was used to evaluate the modeling efficiency. The modeling was improved by including the sensitivity analysis, autocalibration tool and manual adjustment, showing that, with regular sampling frequency, the SWAT 2005 model simulated the flow rate and total phosphorous export satisfactorily. In the case of irregular sampling frequency and limited dataset, however, autocalibration and sensitivity analysis were not efficient to simulate the flow rate and total phosphorous export results. Besides, different sensitivity levels were observed for the two stations, reflecting inequalities of the Hydrologic Response Units. The simulated monthly distribution of phosphorous export showed the heterogeneity of P application over the course of the year.

  19. A Comparative study of solidification of Al-Cu alloy under flow of cylindrical radial heat and the unidirectional vertically

    Directory of Open Access Journals (Sweden)

    Jean Robert P. Rodrigues

    2014-09-01

    Full Text Available In spite of technological importance of solidification of metallic alloys under radial heat flow, relatively few studies have been carried out in this area. In this work the solidification of Al 4.5 wt% Cu cylinders against a steel massive mold is analyzed and compared with unidirectional solidification against a cooled mold. Initially temperature variations at different positions in the casting and in the mold were measured during solidification using a data acquisition system. These temperature variations were introduced in a numerical method in order to determine the variation of heat transfer coefficient at metal/mold interface by inverse method. The primary and secondary dendrite arm spacing variations were measured through optical microscopy. Comparisons carried out between experimental and numerical data showed that the numerical method describes well the solidification processes under radial heat flux.

  20. Comparing flows to a tunnel for single porosity, double porosity and discrete fracture representations of the EDZ

    International Nuclear Information System (INIS)

    Hawkins, I.; Swift, B.; Hoch, A.; Wendling, J.

    2010-01-01

    rock during the operational phase of the repository and subsequent re-saturation of a tunnel post-closure is simulated. The different results (e.g. flows to the tunnel) are compared. (authors)

  1. Analysis of a total flow blockage of a Fuel Assembly in a typical MTR Research Reactor by RELAP5/MOD3.3

    International Nuclear Information System (INIS)

    Adorni, M.; Salah, A.B.; Di Maro, B.; Pierro, F.; D'Auria, F.; Hamidouche, T.

    2004-01-01

    The lack of full understanding of complex mechanisms connected with the interaction between thermal-hydraulics and neutronics still challenge the design and the operation of nuclear reactors by the adoption of conservative safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience imposes the revisiting of those areas and eventually the identification of design/safety requirements that can be relaxed [1]. Currently, the enlarged commercial exploitation of nuclear Research Reactors (RR) has increased the consideration to their corresponding safety issues. Almost all of the safety analyses have so far been performed using conservative computational tools [2]. Nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity in order to increase their commercial productivity. In this framework, an attempt is made to apply the BE technique to perform a safety evaluation under research reactors operational conditions. In fact, this technique has been largely verified and validated for power reactors using coupled system thermal-hydraulic and three-dimensional neutron kinetics [1]. For this purpose, as typical representative of research reactors, the IAEA 10 MW MTR Research Reactors problem [3] is considered. The system thermal-hydraulic RELAP5 [4] code was developed to simulate transient scenarios in Power reactors such PWR, BWR, VVER, etc. However, only limited work was performed to access the applicability of the code to Research Reactors operating conditions (low pressure, mass flow rates, power, etc) [5]. Previous works performed in this field are reported in [5], [6] and [7]. In this framework, total and partial blockage of a single Fuel Assembly cooling channel are investigated. As a first attempt the calculations are performed by applying the BE thermal-hydraulic system code RELAP5 alone using its point kinetic model to derive the instantaneous core

  2. A method to compare calculated and experimental 14 MeV neutron attenuation coefficient and to determine the total removal cross-section

    International Nuclear Information System (INIS)

    Elay, A.G.

    1978-01-01

    A method to compare calculated and experimental neutron attenuation coefficients (chi) when samples are o, different geometries but the same material is proposed. The best Σ (total removal cross section) is determined by using the fact that the logarithm of the attenuation coefficient varies linearly with respect to Σ i.e. lg chi = + asub(s) Σ, where asub(s) is a parameter that characterises all the geometrical experimental conditions of the neutron source, the sample and the relative source-to-sample geometry. In order to increase the precision, samples of different geometries but the same material were used. Values of chi are determined experimentally and asub(s) calculated for these geometries. The graph of lg chi as a function of asub(s) together with a simple fit to a straight line is sufficient to determine Σ (the slope of the line). (T.G.)

  3. Nutritional support of bone marrow transplant recipients: a prospective, randomized clinical trial comparing total parental nutrition to an enteral feeding program

    International Nuclear Information System (INIS)

    Szeluga, D.J.

    1985-01-01

    Allogeneic and autologous bone marrow transplantation (BMT) have been associated with nutritionally-depleting side effects. Total parental nutrition (TPN) has become the standard, but it has not been demonstrated that TPN is the appropriate method of nutritional support. Therefore, in a prospective, randomized clinical trial TPN and enteral feeding were compared for their effectiveness in maintaining the nutritional status of patients through the first 29 post-transplant days. Nutritional assessment included measurement of serum proteins, body weight, anthropometry and isotope dilution analysis of body composition. Total body water (TBW) and extracellular fluid (ECF) were quantified by standard radioisotope dilution techniques using tritiated water and 169 ytterbium-diethylenetriaminepentaacetate, respectively as the tracers. Consenting patients 10-58 years of age were stratified by type of BMT (autologous or allogeneic) and randomized to either TPN plus ad libitum oral feeding or the individualized enteral feeding program (EFP), which included one-on-one counseling, meal-by-meal menu selection, special snacks and tube feeding. There were no differences in the rate of hematologic recovery, incidence of graft-versus-host disease, organ toxicity, length of hospitalization or survival. Therefore, the observed changes in body composition were not clinically significant. Even allowing for increased dietary service, the EFP was only half as expensive as TPN. It was concluded that TPN is not superior to the EFP and therefore, TPN should be reserved for patients who demonstrate intolerance to enteral feeding

  4. Comparative Characterization of Total Flavonol Glycosides and Terpene Lactones at Different Ages, from Different Cultivation Sources and Genders of Ginkgo biloba Leaves

    Directory of Open Access Journals (Sweden)

    Yong Qin

    2012-08-01

    Full Text Available The extract from Ginkgo biloba leaves has become a very popular plant medicine and herbal supplement for its potential benefit in alleviating symptoms associated with peripheral vascular disease, dementia, asthma and tinnitus. Most research on G. biloba leaves focus on the leaves collected in July and August from four to seven year-old trees, however a large number of leaves from fruit cultivars (trees older than 10 years are ignored and become obsolete after fruit harvest season (November. In this paper, we expand the tree age range (from one to 300 years and first comparatively analyze the total flavonol glycosides and terpene lactones at different ages, from different cultivation sources and genders of G. biloba leaves collected in November by using the validated HPLC-ELSD and HPLC-PDA methods. The results show that the contents of total terpene lactones and flavonol glycosides in the leaves of young ginkgo trees are higher than those in old trees, and they are higher in male trees than in female trees. Geographical factors appear to have a significant influence on the contents as well. These results will provide a good basis for the comprehensive utilization of G. biloba leaves, especially the leaves from fruit cultivars.

  5. Clinical and radiological outcome of the Total Evolutive Shoulder System (TESS®) reverse shoulder arthroplasty: a prospective comparative non-randomised study.

    Science.gov (United States)

    Kadum, Bakir; Mukka, Sebastian; Englund, Erling; Sayed-Noor, Arkan; Sjödén, Göran

    2014-05-01

    The aims of this study were to assess the function and quality of life after the Total Evolutive Shoulder System (TESS) reverse shoulder arthroplasty (RSA), to evaluate the radiological stability of the stemless version and to address the effect of arm lengthening and scapular notching (SN) on the outcome. This was a prospective comparative non-randomised study. A total of 37 consecutive patients (40 shoulders) underwent TESS RSA between October 2007 and January 2012; 16 were stemless and 26 were stemmed. At a mean follow-up of 39 months (15-66), we evaluated range of motion (ROM), pain and functional outcome with QuickDASH and quality of life with EQ-5D score. Radiologically, component positioning, signs of loosening, SN and arm length difference were documented. We found a significant improvement in functional outcome and reduction of pain in both stemmed and stemless groups. No humeral loosening was evident, but there were four glenoid loosenings. In 12 shoulders that developed SN, seven already had scapular bone impression (SBI) evident on initial post-operative radiographs. Glenoid overhang seemed to decrease the risk of SN. Arm lengthening was associated with better EQ-5D but did not influence ROM or functional outcome. Reverse shoulder arthroplasty markedly improved shoulder function. SN is of concern in RSA, but proper positioning of the glenoid component may prevent its development.

  6. A comparative study of the effect of clonidine, fentanyl, and the combination of both as adjuvant to intrathecal bupivacaine for postoperative analgesia in total abdominal hysterectomy

    Science.gov (United States)

    Ahmed, Fareed; Khandelwal, Mamta; Sharma, Anil

    2017-01-01

    Background and Aims: The aim of this study was to evaluate the level of sensory block, onset and duration of motor block, postoperative analgesia, and adverse effects of combination of clonidine and fentanyl given intrathecally with hyperbaric bupivacaine (HB). Material and Methods: Three hundred and twenty eight patients were randomized into four groups. Group bupivacaine (group B) received 15 mg of HB; group bupivacaine clonidine (group BC) received 15 mg of HB plus 25 μg clonidine; group bupivacaine fentanyl (group BF) received 15 mg of HB plus 25 μg fentanyl and group bupivacaine clonidine fentanyl (group BCF) received 15 mg of HB plus 25 μg clonidine and 25 μg fentanyl intrathecally. All groups were evaluated for level of sensory block, onset and duration of motor block, postoperative analgesia, VAS score, sedation score and adverse effects of study drugs. All the data were analyzed using unpaired t-test. P < 0.05 was considered significant. Results: The level of sensory block, onset, and duration of motor block were comparable in all groups. Total duration of analgesia was 407.3 ± 20 min in group BCF compared to 242.1 ± 2 min and 209.2 ± 16 in groups BC and BF, respectively. Lesser doses of rescue analgesic were required in group BCF. The time interval from intrathecal injection to two-segment regression was statistically significant in study groups. Only 2.4% patients showed mild sedation in BCF group. Conclusion: We found that combination of intrathecal clonidine and fentanyl along with bupivacaine increases the total duration of analgesia without significant side effects. PMID:28413281

  7. Comparative Analyses of Nonpathogenic, Opportunistic, and Totally Pathogenic Mycobacteria Reveal Genomic and Biochemical Variabilities and Highlight the Survival Attributes of Mycobacterium tuberculosis

    Science.gov (United States)

    Singh, Yadvir; Kohli, Sakshi; Ahmad, Javeed; Ehtesham, Nasreen Z.; Tyagi, Anil K.

    2014-01-01

    ABSTRACT Mycobacterial evolution involves various processes, such as genome reduction, gene cooption, and critical gene acquisition. Our comparative genome size analysis of 44 mycobacterial genomes revealed that the nonpathogenic (NP) genomes were bigger than those of opportunistic (OP) or totally pathogenic (TP) mycobacteria, with the TP genomes being smaller yet variable in size—their genomic plasticity reflected their ability to evolve and survive under various environmental conditions. From the 44 mycobacterial species, 13 species, representing TP, OP, and NP, were selected for genomic-relatedness analyses. Analysis of homologous protein-coding genes shared between Mycobacterium indicus pranii (NP), Mycobacterium intracellulare ATCC 13950 (OP), and Mycobacterium tuberculosis H37Rv (TP) revealed that 4,995 (i.e., ~95%) M. indicaus pranii proteins have homology with M. intracellulare, whereas the homologies among M. indicus pranii, M. intracellulare ATCC 13950, and M. tuberculosis H37Rv were significantly lower. A total of 4,153 (~79%) M. indicus pranii proteins and 4,093 (~79%) M. intracellulare ATCC 13950 proteins exhibited homology with the M. tuberculosis H37Rv proteome, while 3,301 (~82%) and 3,295 (~82%) M. tuberculosis H37Rv proteins showed homology with M. indicus pranii and M. intracellulare ATCC 13950 proteomes, respectively. Comparative metabolic pathway analyses of TP/OP/NP mycobacteria showed enzymatic plasticity between M. indicus pranii (NP) and M. intracellulare ATCC 13950 (OP), Mycobacterium avium 104 (OP), and M. tuberculosis H37Rv (TP). Mycobacterium tuberculosis seems to have acquired novel alternate pathways with possible roles in metabolism, host-pathogen interactions, virulence, and intracellular survival, and by implication some of these could be potential drug targets. PMID:25370496

  8. Long-term survival benefit of revascularization compared with medical therapy in patients with coronary chronic total occlusion and well-developed collateral circulation.

    Science.gov (United States)

    Jang, Woo Jin; Yang, Jeong Hoon; Choi, Seung-Hyuk; Song, Young Bin; Hahn, Joo-Yong; Choi, Jin-Ho; Kim, Wook Sung; Lee, Young Tak; Gwon, Hyeon-Cheol

    2015-02-01

    The purpose of this study was to compare the long-term clinical outcomes of patients with chronic total occlusion (CTO) and well-developed collateral circulation treated with revascularization versus medical therapy. Little is known about the clinical outcomes and optimal treatment strategies of CTO with well-developed collateral circulation. We screened 2,024 consecutive patients with at least 1 CTO detected on coronary angiogram. Of these, we analyzed data from 738 patients with Rentrop 3 grade collateral circulation who were treated with medical therapy alone (n = 236), coronary artery bypass grafting (n = 170) or percutaneous coronary intervention (n = 332; 80.1% successful). Patients who underwent revascularization and medical therapy (revascularization group, n = 502) were compared with those who underwent medical therapy alone (medication group, n = 236) in terms of cardiac death and major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction, and repeat revascularization. During a median follow-up duration of 42 months, multivariate analysis revealed a significantly lower incidence of cardiac death (hazard ratio [HR]: 0.29; 95% confidence interval [CI]: 0.15 to 0.58; p collateral circulation, aggressive revascularization may reduce the risk of cardiac mortality and MACE. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Empirical Correlations and CFD Simulations of Vertical Two-Phase Gas-Liquid (Newtonian and Non-Newtonian) Flow Compared Against Experimental Data of Void Fraction and Pressure Drop

    DEFF Research Database (Denmark)

    Ratkovich, Nicolas Rios; Bentzen, Thomas Ruby; Majumder, S.K.

    2012-01-01

    Gas-Newtonian liquid two-phase flows (TPFs) are presented in several industrial processes (i.e. oil-gas industry). In spite of the common occurrence of these TPFs, their understanding is limited compared to single-phase flows. Different studies on TPF have focus on developing empirical correlations...... based in large sets of experiment data for void fraction and pressure drop which have proven to be accurate for specific condition that their where developed for, which limit their applicability. On the other hand, scarce studies focus on gas-non-Newtonian liquids TPFs, which are very common in chemical...... processes. The main reason for it is due to the characterization of the viscosity, which determines the hydraulic regime and flow behaviours on the system. The focus of this study is the analysis of the TPF for Newtonian and non-Newtonian liquids in a vertical pipe in terms of void fraction and total...

  10. Outbreaks, gene flow and effective population size in the migratory locust, Locusta migratoria: a regional-scale comparative survey.

    Science.gov (United States)

    Chapuis, Marie-Pierre; Loiseau, Anne; Michalakis, Yannis; Lecoq, Michel; Franc, Alex; Estoup, Arnaud

    2009-03-01

    The potential effect of population outbreaks on within and between genetic variation of populations in pest species has rarely been assessed. In this study, we compare patterns of genetic variation in different sets of historically frequently outbreaking and rarely outbreaking populations of an agricultural pest of major importance, the migratory locust, Locusta migratoria. We analyse genetic variation within and between 24 populations at 14 microsatellites in Western Europe, where only ancient and low-intensity outbreaks have been reported (non-outbreaking populations), and in Madagascar and Northern China, where frequent and intense outbreak events have been recorded over the last century (outbreaking populations). Our comparative survey shows that (i) the long-term effective population size is similar in outbreaking and non-outbreaking populations, as evidenced by similar estimates of genetic diversity, and (ii) gene flow is substantially larger among outbreaking populations than among non-outbreaking populations, as evidenced by a fourfold to 30-fold difference in FST values. We discuss the implications for population dynamics and the consequences for management strategies of the observed patterns of genetic variation in L. migratoria populations with contrasting historical outbreak frequency and extent.

  11. A multi-perspective cost-effectiveness analysis comparing rivaroxaban with enoxaparin sodium for thromboprophylaxis after total hip and knee replacement in the German healthcare setting

    Directory of Open Access Journals (Sweden)

    Zindel Sonja

    2012-07-01

    Full Text Available Abstract Background Patients undergoing major orthopaedic surgery (MOS, such as total hip (THR or total knee replacement (TKR, are at high risk of developing venous thromboembolism (VTE. For thromboembolism prophylaxis, the oral anticoagulant rivaroxaban has recently been included in the German diagnosis related group (DRG system. However, the cost-effectiveness of rivaroxaban is still unclear from both the German statutory health insurance (SHI and the German hospital perspective. Objectives To assess the cost-effectiveness of rivaroxaban from the German statutory health insurance (SHI perspective and to analyse financial incentives from the German hospital perspective. Methods Based on data from the RECORD trials and German cost data, a decision tree was built. The model was run for two settings (THR and TKR and two perspectives (SHI and hospital per setting. Results Prophylaxis with rivaroxaban reduces VTE events (0.02 events per person treated after TKR; 0.007 after THR compared with enoxaparin. From the SHI perspective, prophylaxis with rivaroxaban after TKR is cost saving (€27.3 saving per patient treated. However, the cost-effectiveness after THR (€17.8 cost per person remains unclear because of stochastic uncertainty. From the hospital perspective, for given DRGs, the hospital profit will decrease through the use of rivaroxaban by €20.6 (TKR and €31.8 (THR per case respectively. Conclusions Based on our findings, including rivaroxaban for reimbursement in the German DRG system seems reasonable. Yet, adequate incentives for German hospitals to use rivaroxaban are still lacking.

  12. Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after five years minimum.

    Science.gov (United States)

    Yoon, Jung-Ro; Yang, Jae-Hyuk

    2018-03-20

    The purpose of this retrospective study was to analyze and compare the clinical and radiologic outcomes of fixed bearing ultracongruent (UC) insert total knee arthroplasty (TKA) and mobile bearing (MB) floating platform TKA using the navigation-assisted gap balancing technique with a minimum follow-up of five years. The study retrospectively enrolled 105 patients who received the UC type fixed bearing insert (group 1) and 95 patients who received the floating platform MB insert (group 2) during the period from August 2009 to June 2012. All surgery was performed using the navigation-assisted gap balancing technique. For strict assessment of gap measurements, the offset-type-force-controlled-spreader-system was used. Radiologic and clinical outcomes were assessed before operation and at the most recent follow-up using the Knee Society Score (KSS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. For statistical analysis, paired sample t tests were used. A p value less than 0.05 was considered significant. Although the radiologic alignments were satisfactory for both groups (99/105 [94%] cases were neutral for group 1 and 90/95 [94%] for group 2), the functional and total WOMAC scores were inferior in group 2 (p bearing exchange. The Kaplan-Meier survivorship rates for groups 1 and 2 at 77 months were 100.0 and 97.9%, respectively. Second-generation MB floating platform TKA cases did not have satisfactory outcomes. There were two cases of insert breakage, which required bearing exchange. Other patients who underwent surgery with second-generation MB floating platform were encouraged to avoid high knee flexion activities, resulting in lower clinical performance.

  13. Preliminary results of a randomized trial comparing 400 cGy vs 700 cGy as an adjuvant to prevent heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Nguyen, Cam; Gupta-Burt, Shalina; Silverton, Craig; Cummings, Marilyn; Galante, Jorge O.

    1997-01-01

    Purpose/Objective: We report our preliminary results of a randomized trial comparing one single dose of 400 cGy versus 700 cGy given postoperatively in an attempt to prevent heterotopic ossification after total hip arthroplasty. Materials and Methods: From 09/1993 and 05/1996, over 800 total hip replacements were performed at our hospital. From this group of patients, 120 hips in 114 high-risk patients (14%) were enrolled in a randomized trial to determine if 400 cGy (Group A) is as efficacious as 700 cGy (Group B) in preventing heterotopic ossification. In Group A, there were 42 males (46 hips) and 12 females (12 hips) with a mean age of 60 (range 41-79); with 18 primary cementless femoral components (33%), 30 primary cemented stems (55%) and 10 revisions. In Group B, there were 30 males (32 hips) and 30 females (31 hips) with a median age of 59 (range 41-85); with 12 primary cementless femoral components (20%), 44 primary cemented stems (73%) and 6 revisions. All acetabular components were of the cementless type. Patients were randomized to receive either 400 cGy or 700 cGy in one fraction. Radiotherapy is given within 48 hours post-operatively using paired anterior and posterior fields, with blocking of the cementless acetabular component and the femoral component. Results: All 114 patients were available for a minimum follow-up of 6 months (range 6-30 months). None of the arthroplasties has failed at the latest follow-up. There were no radiation therapy complications noted. Statistical analysis revealed no difference in the distribution of patients in either group according to age, sex, primary or revision arthroplasty, cemented or cementless femoral component fixation, preoperative heterotopic ossification risk, or surgical approach. Of the 58 hips in Group A, heterotopic ossification was graded as Grade 0 in 24 hips, Grade I in 10 hips, Grade II in 18 hips, Grade III in 6 hips, with no cases of Grade IV. Of the 63 hips in Group B, heterotopic ossification was

  14. Prospective comparative study of brain protection in total aortic arch replacement: deep hypothermic circulatory arrest with retrograde cerebral perfusion or selective antegrade cerebral perfusion.

    Science.gov (United States)

    Okita, Y; Minatoya, K; Tagusari, O; Ando, M; Nagatsuka, K; Kitamura, S

    2001-07-01

    The purpose of this study was to compare the results of total aortic arch replacement using two different methods of brain protection, particularly with respect to neurologic outcome. From June 1997, 60 consecutive patients who underwent total arch replacement through a midsternotomy were alternately allocated to one of two methods of brain protection: deep hypothermic circulatory arrest with retrograde cerebral perfusion (RCP: 30 patients) or with selective antegrade cerebral perfusion (SCP: 30 patients). Preoperative and postoperative (3 weeks) brain CT scan, neurological examination, and cognitive function tests were performed. Serum 100b protein was assayed before and after the cardiopulmonary bypass, as well as 24 hours and 48 hours after the operation. Hospital mortality occurred in 2 patients in the RCP group (6.6%) and 2 in the SCP group (6.6%). New strokes occurred in 1 (3.3%) of the RCP group and in 2 (6.6%) of the SCP group (p = 0.6). The incidence of transient brain dysfunction was significantly higher in the RCP group than in the SCP group (10, 33.3% vs 4, 13.3%, p = 0.05). Except in patients with strokes, S-100b values showed no significant differences in the two groups (RCP: SCP, prebypass 0.01+/-0.04: 0.05+/-0.16, postbypass 2.17+/-0.94: 1.97+/-1.00, 24 hours 0.61+/-0.36: 0.60+/-0.37, 48 hours 0.36+/-0.45: 0.46+/-0.40 microg/L, p = 0.7). There were no intergroup differences in the scores of memory decline (RCP 0.74+/-0.99; SCP 0.55+/-1.19, p = 0.6), orientation (RCP 1.11+/-1.29; SCP 0.50+/-0.76, p = 0.08), or intellectual function (RCP 1.21+/-1.27; SCP 1.05+/-1.15, p = 0.7). Both methods of brain protection for patients undergoing total arch replacement resulted in acceptable levels of mortality and morbidity. However, the prevalence of transient brain dysfunction was significantly higher in patients with the RCP.

  15. Project subsidized by the Sunshine Project in fiscal 1982. Report on achievements in the project commissioned from NEDO for development of a total flow power generation plant (Two-phase rotation inflator); 1982 nendo total flow hatsuden plant no kaihatsu seika hokokusho. Niso kaiten bochoki

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-07-01

    Developmental research has been performed on a two-phase rotation inflator in the total flow power generation technology to inflate gas-liquid two-phase fluid containing a great amount of hot water in the form as it is to draw out output. Subsequently from the previous fiscal year, the present fiscal year has improved the performance of a 300-kW class two-phase rotation inflator. The factory test data acquired in the previous fiscal year were analyzed, and an investigation was given on the cause of leakage loss and machine loss which were greater than what has been expected initially. The result revealed leakage from the circumferential seal grooves and leakage due to increase in the side seal clearance as a result of deformation of the external rotor flange. In addition, the static pressure bearing was found to have small displacement in the shaft center, but have large loss. Small modifications on these deficiencies raised the engine efficiency by about 44% at a rotation speed of 1,200 rpm, proving the effect of the improvement. However, the inflator showed a trend that, at the rotation speed higher than 1,600 rpm, air intake amount has increased, and the output has decreased. Therefore, analyses and investigations were carried out on water film loss, bearing loss and machine loss, and total modification was given on the inner and outer rotors, the inner wheel chamber, the sealing device, and the bearings. (NEDO)

  16. Knee Joint Distraction Compared to Total Knee Arthroplasty for Treatment of End Stage Osteoarthritis: Simulating Long-Term Outcomes and Cost-Effectiveness.

    Science.gov (United States)

    van der Woude, J A D; Nair, S C; Custers, R J H; van Laar, J M; Kuchuck, N O; Lafeber, F P J G; Welsing, P M J

    2016-01-01

    In end-stage knee osteoarthritis the treatment of choice is total knee arthroplasty (TKA). An alternative treatment is knee joint distraction (KJD), suggested to postpone TKA. Several studies reported significant and prolonged clinical improvement of KJD. To make an appropriate decision regarding the position of this treatment, a cost-effectiveness and cost-utility analysis from healthcare perspective for different age and gender categories was performed. A treatment strategy starting with TKA and a strategy starting with KJD for patients of different age and gender was simulated. To extrapolate outcomes to long-term health and economic outcomes a Markov (Health state) model was used. The number of surgeries, QALYs, and treatment costs per strategy were calculated. Costs-effectiveness is expressed using the cost-effectiveness plane and cost-effectiveness acceptability curves. Starting with KJD the number of knee replacing procedures could be reduced, most clearly in the younger age categories; especially revision surgery. This resulted in the KJD strategy being dominant (more effective with cost-savings) in about 80% of simulations (with only inferiority in about 1%) in these age categories when compared to TKA. At a willingness to pay of 20.000 Euro per QALY gained, the probability of starting with KJD to be cost-effective compared to starting with a TKA was already found to be over 75% for all age categories and over 90-95% for the younger age categories. A treatment strategy starting with knee joint distraction for knee osteoarthritis has a large potential for being a cost-effective intervention, especially for the relatively young patient.

  17. Brix refractometry in serum as a measure of failure of passive transfer compared to measured immunoglobulin G and total protein by refractometry in serum from dairy calves.

    Science.gov (United States)

    Hernandez, D; Nydam, D V; Godden, S M; Bristol, L S; Kryzer, A; Ranum, J; Schaefer, D

    2016-05-01

    A series of trials were conducted to evaluate Brix refractometry (Brix %) for the assessment of failure of passive transfer (FPT) in dairy calves compared to: (1) serum IgG (reference standard) when measured by radial immunodiffusion (RID) or a turbidometric immunoassay (TIA), and (2) serum total protein refractometry (STP). For the serum samples tested with TIA, STP, and Brix % (n = 310; Holstein calves), the median concentrations were 21.3 g/L IgG, 58 g/L STP, and 9.2%, respectively. For the serum samples tested with RID, STP and Brix % (n = 112; Jersey calves), the mean concentrations were 38 g/L IgG, 68 g/L STP, and 10.2%, respectively. For samples tested with only Brix % and STP (n = 265; Holstein calves), median STP and Brix % were 50 g/L STP and 8.5%, respectively. Correlations between Brix % and RID, and between Brix % and TIA were equal (r = 0.79, respectively). Brix % and STP were positively correlated (r = 0.99). Brix % estimated serum IgG concentrations determined by TIA and RID (r(2) = 0.63, 0.62, respectively). When FPT was defined as serum IgG refractometry predicted successful transfer of passive immunity in dairy calves, but further evaluation as a diagnostic tool for the diagnosis of FPT is warranted. Copyright © 2016. Published by Elsevier Ltd.

  18. Comparing calculated free testosterone with total testosterone for screening and diagnosing late-onset hypogonadism in aged males: A cross-sectional study.

    Science.gov (United States)

    Liu, Zhangshun; Liu, Jie; Shi, Xiaohong; Wang, Lihong; Yang, Yan; Tao, Minfang; Fu, Qiang

    2017-09-01

    The aim of this study is to compare calculated free testosterone (cFT) and total testosterone (T) in predicting late-onset hypogonadism (LOH) in middle-aged and elderly males. We surveyed a random sample of 608 males between the ages of 45 and 87 years from Shanghai, China. The Aging Male Symptoms (AMS) questionnaire and the Androgen Deficiency in Aging Male (ADAM) questionnaire were completed by the subjects. Testosterone (T), sex hormone-binding globulin (SHBG), albumin, and other blood biochemical indexes were measured in 332 males. The corresponding cFT was obtained using the Vermeulen formula and the correlations between T and cFT were analyzed by SPSS statistical software. Among the 332 males who underwent biochemical evaluation, 289 males (87.0%) was positively screened by the ADAM questionnaire and 232 males (69.9%) by the AMS questionnaire. As suggested by linear regression, cFT exhibited a negative correlation with age in both ADAM+ and AMS+ group, whereas T did not appear to have significant correlation with age. Besides, there were statistically significant differences in cFT (Pmales. © 2016 Wiley Periodicals, Inc.

  19. Comparative study of portal hemodynamics and regional hepatic blood flow before and after hepatic resection by 133Xe-scintiphotosplenoportography

    International Nuclear Information System (INIS)

    Yasuda, Tadashi; Sasaki, Yo; Imaoka, Shingi; Shibata, Takashi; Wada, Hisashi; Nagano, Hiroaki; Iwanaga, Takeshi; Nakano, Shunichi; Hasegawa, Yoshihisa.

    1990-01-01

    Changes in the portal circulatory pattern and regional hepatic blood flow (rHBF) after surgical liver resection were studied by 133 Xe-scintiphotosplenoportography (SSP). The visual patterns of pre- and postoperative portal circulation were compared. Different patterns were observed after the operation in five of 27 patients (porto-systemic shunt formation 3, progression 1, regression 1). The patients with porto-systemic shunt showed postopertive complications (massive ascites, jaundice, cardiopulmonary failure) more frequently than those without it. The ratio of rHBF increase (post-/pre-operative rHBF) was 1.36±0.63 on average. The ratio was higher in patients with good liver function or without liver cirrhosis. The ratio also correlated with the weight of the liver resected. But operation time, blood loss or whether hepatic blood supply was clamped off during the operation did not affect the ratio. Resection in the right lobe, however, caused a greater rHBF increase in the residual liver than the same degree of resection in the left lobe. SSP could be a useful method for investigating the effect of hepatic resection on portal hemodynamics and it is suggested that existence of portosystemic shunt influences the postoperative course. (author)

  20. A comparative study of in-flow and micro-patterning biofunctionalization protocols for nanophotonic silicon-based biosensors.

    Science.gov (United States)

    González-Guerrero, Ana Belén; Alvarez, Mar; García Castaño, Andrés; Domínguez, Carlos; Lechuga, Laura M

    2013-03-01

    Reliable immobilization of bioreceptors over any sensor surface is the most crucial step for achieving high performance, selective and sensitive biosensor devices able to analyze human samples without the need of previous processing. With this aim, we have implemented an optimized scheme to covalently biofunctionalize the sensor area of a novel nanophotonic interferometric biosensor. The proposed method is based on the ex-situ silanization of the silicon nitride transducer surface by the use of a carboxyl water soluble silane, the carboxyethylsilanetriol sodium salt (CTES). The use of an organosilane stable in water entails advantages in comparison with usual trialkoxysilanes such as avoiding the generation of organic waste and leading to the assembly of compact monolayers due to the high dielectric constant of water. Additionally, cross-linking is prevented when the conditions (e.g. immersion time, concentration of silane) are optimized. This covalent strategy is followed by the bioreceptor linkage on the sensor area surface using two different approaches: an in-flow patterning and a microcontact printing using a biodeposition system. The performance of the different bioreceptor layers assembled is compared by the real-time and label-free immunosensing of the proteins BSA/mAb BSA, employed as a model molecular pair. Although the results demonstrated that both strategies provide the biosensor with a stable biological interface, the performance of the bioreceptor layer assembled by microcontact printing slightly improves the biosensing capabilities of the photonic biosensor. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  2. Species transport mechanisms governing capacity loss in vanadium flow batteries: Comparing Nafion® and sulfonated Radel membranes

    International Nuclear Information System (INIS)

    Agar, Ertan; Knehr, K.W.; Chen, D.; Hickner, M.A.; Kumbur, E.C.

    2013-01-01

    Highlights: • Species transport mechanisms are investigated in Nafion ® and s-Radel for VRFBs. • Unlike diffusion in Nafion ® , crossover in s-Radel is dominated by convection. • In particular, electro-osmotic convection is the dominant mode in s-Radel. • Change in direction of convection causes a lower crossover in s-Radel. • Hydraulic and electrokinetic permeability are as important as vanadium permeability. -- Abstract: In this study, a 2-D, transient vanadium redox flow battery (VRFB) model was used to investigate and compare the ion transport mechanisms responsible for vanadium crossover in Nafion ® 117 and sulfonated Radel (s-Radel) membranes. Specifically, the model was used to distinguish the relative contribution of diffusion, migration, osmotic and electro-osmotic convection to the net vanadium crossover in Nafion ® and s-Radel. Model simulations indicate that diffusion is the dominant mode of vanadium transport in Nafion ® , whereas convection dominates the vanadium transport through s-Radel due to the lower vanadium permeability, and thus diffusivity of s-Radel. Among the convective transport modes, electro-osmotic convection (i.e., electro-osmotic drag) is found to govern the species crossover in s-Radel due to its higher fixed acid concentration and corresponding free ions in the membrane. Simulations also show that vanadium crossover in s-Radel changes direction during charge and discharge due to the change in the direction of electro-osmotic convection. This reversal in the direction of crossover during charge and discharge is found to result in significantly lower “net” crossover for s-Radel when compared to Nafion ® . Comparison of these two membranes also provides guidance for minimizing crossover in VRFB systems and underscores the importance of measuring the hydraulic and the electro-kinetic permeability of a membrane in addition to vanadium diffusion characteristics, when evaluating new membranes for VRFB applications

  3. Pulmonary Artery Catheter (PAC Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM: An Ovine Cardiac Output Validation

    Directory of Open Access Journals (Sweden)

    Robert A. Phillips

    2012-01-01

    Full Text Available Background. The pulmonary artery catheter (PAC is an accepted clinical method of measuring cardiac output (CO despite no prior validation. The ultrasonic cardiac output monitor (USCOM is a noninvasive alternative to PAC using Doppler ultrasound (CW. We compared PAC and USCOM CO measurements against a gold standard, the aortic flow probe (FP, in sheep at varying outputs. Methods. Ten conscious sheep, with implanted FPs, had measurements of CO by FP, USCOM, and PAC, at rest and during intervention with inotropes and vasopressors. Results. CO measurements by FP, PAC, and USCOM were 4.0±1.2 L/min, 4.8±1.5 L/min, and 4.0±1.4 L/min, respectively, (=280, range 1.9 L/min to 11.7 L/min. Percentage bias and precision between FP and PAC, and FP and USCOM was −17 and 47%, and 1 and 36%, respectively. PAC under-measured Dobutamine-induced CO changes by 20% (relative 66% compared with FP, while USCOM measures varied from FP by 3% (relative 10%. PAC reliably detected −30% but not +40% CO changes, as measured by receiver operating characteristic area under the curve (AUC, while USCOM reliably detected ±5% changes in CO (AUC>0.70. Conclusions. PAC demonstrated poor accuracy and sensitivity as a measure of CO. USCOM provided equivalent measurements to FP across a sixfold range of outputs, reliably detecting ±5% changes.

  4. Patient directed self management of pain (PaDSMaP compared to treatment as usual following total knee replacement: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Donell Simon

    2012-11-01

    Full Text Available Abstract Background In 2009, 665 patients underwent total knee replacements (TKRs at the Norfolk and Norwich University Hospitals NHS Foundation Trust (NNUH, representing nearly 1% of the national total. Pain control following the operation can be poor, and this can cause poor mobilization and potential long-term adverse events. Although high levels of pain are not associated with patient dissatisfaction, brief periods of pain may lead to neuronal remodeling and sensitization. Patient controlled oral analgesia (PCOA may improve pain relief; however, the evidence to date has been inconclusive. Patient directed self management of pain (PaDSMaP is a single center randomized controlled trial, which aims to establish if patient self-medication improves, or is equivalent to, treatment as usual and to create an educational package to allow implementation elsewhere. Methods/design Patients eligible for a TKR will be recruited and randomized in the outpatient clinic. All patients will undergo their operations according to normal clinical practice but will be randomized into two groups. Once oral medication has commenced, one group will have pain relief administered by nursing staff in the usual way (treatment as usual; TAU, whilst the second group will self manage their pain medication (patient directed self management of pain; PaDSMaP. Those recruited for self-medication will undergo a training program to teach the use of oral analgesics according to the World Health Organization (WHO pain cascade and how to complete the study documentation. The primary endpoint of the trial is the visual analogue scale (VAS pain score at 3 days or discharge, whichever is sooner. The follow-up time is 6 weeks with a planned trial period of 3 years. The secondary objectives are satisfaction with the management of patient pain post-operatively whilst an inpatient after primary TKR; overall pain levels and pain on mobilization; satisfaction with pain management information

  5. Effects of Focal vs Total Cryotherapy and Minimum Tumor Temperature on Patient-reported Quality of Life Compared With Active Surveillance in Patients With Prostate Cancer.

    Science.gov (United States)

    Werneburg, Glenn T; Kongnyuy, Michael; Halpern, Daniel M; Salcedo, Jose M; Chen, Connie; LeSueur, Amanda; Kosinski, Kaitlin E; Schiff, Jeffrey T; Corcoran, Anthony T; Katz, Aaron E

    2018-03-01

    To investigate the effects of focal (hemiablation) or total cryotherapy and minimum tumor temperature on patient-reported quality of life (QoL) in patients with prostate cancer. An Institutional Review Board-approved database was reviewed for patients who underwent cryotherapy or active surveillance (AS). QoL questionnaire responses were collected and scores were analyzed for differences between focal and total cryotherapy and between very cold (total of 197 patients responded to a total of 547 questionnaires. Focal and total cryotherapy patients had initially lower sexual function scores relative to AS (year 1 mean difference focal: -31.7, P total: -48.1, P total cryotherapy sexual function scores were not statistically significantly different from the AS cohort by postprocedural year 4. Very cold and moderate-cold temperatures led to initially lower sexual function scores relative to AS (year 1 very cold: -38.1, P total cryotherapy and between very cold and moderate-cold temperature groups. Focal cryotherapy and moderate-cold (≥-76°C) temperature were associated with favorable sexual function relative to total cryotherapy and very cold temperature, respectively. No significant differences in urinary function or bowel habits were observed between groups. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Comparative study of skin blood flow in various types of delayed deltopectoral flaps using the xenon-133 clearance method

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchida, Yukihide; Ogo, Ken (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine); Tsuya, Akira; Uchida, Masaoki; Kamata, Shinetsu; Ohura, Takehiko

    1984-07-01

    We investigated the skin blood flow in five types of delayed deltopectoral flaps and the optimal time for transfer after delay operation using the local clearance method of Xenon-133. The results obtained are reported. 1) Characteristic differences were observed in recovery patterns of the distal blood flow among the five types of delay procedure. 2) The recovery in the distal blood flow of the D-P flap lined with a split-skin graft appeared the fastest among the five types, followed by the tubed D-P flap. 3) When using a bipedicled D-P flap, lateral incision should be performed within 10 days after delay procedure. 4) The skin blood flow of less than 5 ml/100g/min indicated a high risk of necrosis of the deltopectoral flap. 5) The optimal time for transfer was found to be when the skin blood flow of the distal region recovered to the control level.

  7. Using FlowLab, an educational computational fluid dynamics tool, to perform a comparative study of turbulence models

    International Nuclear Information System (INIS)

    Parihar, A.; Kulkarni, A.; Stern, F.; Xing, T.; Moeykens, S.

    2005-01-01

    Flow over an Ahmed body is a key benchmark case for validating the complex turbulent flow field around vehicles. In spite of the simple geometry, the flow field around an Ahmed body retains critical features of real, external vehicular flow. The present study is an attempt to implement such a real life example into the course curriculum for undergraduate engineers. FlowLab, which is a Computational Fluid Dynamics (CFD) tool developed by Fluent Inc. for use in engineering education, allows students to conduct interactive application studies. This paper presents a synopsis of FlowLab, a description of one FlowLab exercise, and an overview of the educational experience gained by students through using FlowLab, which is understood through student surveys and examinations. FlowLab-based CFD exercises were implemented into 57:020 Mechanics of Fluids and Transport Processes and 58:160 Intermediate Mechanics of Fluids courses at the University of Iowa in the fall of 2004, although this report focuses only on experiences with the Ahmed body exercise, which was used only in the intermediate-level fluids class, 58:160. This exercise was developed under National Science Foundation funding by the authors of this paper. The focus of this study does not include validating the various turbulence models used for the Ahmed body simulation, because a two-dimensional simplification was applied. With the two-dimensional simplification, students may setup, run, and post process this model in a 50 minute class period using a single-CPU PC, as required for the 58:160 class at the University of Iowa. It is educational for students to understand the implication of a two- dimensional approximation for essentially a three-dimensional flow field, along with the consequent variation in both qualitative and quantitative results. Additionally, through this exercise, students may realize that the choice of the respective turbulence model will affect simulation prediction. (author)

  8. 14CO2 labeling. A reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crop plants

    International Nuclear Information System (INIS)

    Bhupinder Singh; Sumedha Ahuja; Renu Pandey; Singhal, R.K.

    2014-01-01

    Root release of organic compounds and rate of the vascular sap flow are important for understanding the nutrient and the source-sink dynamics in plants, however, their determination is procedurally cumbersome and time consuming. We report here a simple method involving 14 C labeling for rapid and reliable measurement of root exudates and vascular sap flow rate in a variable groundnut population developed through seed gamma irradiation using a cobalt source ( 60 Co). An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  9. Techno-economic analysis of lignite fuelled IGCC with CO{sub 2} capture. Comparing fluidized bed and entrained flow gasifiers

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Guangjian; Wu, Zhen; Zhang, Haiying [North China Electric Power Univ., Beijing (China). School of Energy and Power Engineering

    2013-07-01

    Integrated coal gasification combined cycle (IGCC) plants with pre-combustion capture of CO{sub 2} represent one of the most promising options for generating low-cost decarbonized power using bituminous coals. This work systematically quantify the effect of coal rank on the efficiency and economics of IGCC systems with CO2 capture and storage (CCS), with a special focus on comparison of systems using fluidized-bed gasifier (U-GAS) and entrained flow gasifier (Shell). It was found that the Shell IGCCs are little affect by low rank coal after pre-drying in terms of thermal efficiency and the levelized cost of electricity (LCOE) is only increase by 2-6% for lignite cases with and without CCS compared with bituminous coal cases. The specific CO{sub 2} emissions of U-GAS gasifier based lignite fuelled IGCC with CCS is 198 g/kWhe, almost two times of shell gasifier cases, mainly due to lower carbon conversion in the gasifier and the higher methane in the raw gas of gasifier. However, the total capital cost and COE of U-Gas IGCCs are 15-20% less than that of Shell IGCCs because of lower capital cost of gasifier, coal drying units and air separate units per kWe.

  10. Comparative evaluation and correlation of salivary total antioxidant capacity and salivary pH in caries-free and severe early childhood caries children.

    Science.gov (United States)

    Muchandi, Sneha; Walimbe, Hrishikesh; Bijle, Mohammed Nadeem Ahmed; Nankar, Meenakshi; Chaturvedi, Srishti; Karekar, Priyanka

    2015-03-01

    Dental caries is a major problem in preschool children. The contribution of saliva in providing defense during caries process is of primary importance. pH buffer capacity through bicarbonate, phosphate and protein buffer systems have universal acceptance as a caries defense mechanism. Antioxidant capacity of saliva can constitute a first line of defense against chronic degenerative diseases including dental caries. Till date, no study is presented with salivary antioxidant capacity of younger children affected with severe early childhood caries with its salivary pH correlation. Hence, this study was carried out to compare, evaluate and correlate the salivary total antioxidant capacity (TAC) and salivary pH of children with caries-free and severe early childhood caries. Fifty children from ages 3 to 5 years divided into two study groups had undergone screening. Group I (n = 25) with severe early childhood caries (S-ECC) and group II (n = 25) who were caries free. Unstimulated whole saliva of subjects were in the collection during the study by draining method. Salivary pH determination of saliva samples was done using pH indicator paper strips. The TAC was done using an antioxidant assay with the help of a spectrophotometer at wavelength 532 nm. The means of salivary pH and TAC were subjected to analysis using unpaired student 't' test and correlation was determined using Pearsons correlation coefficient analysis. Mean salivary pH was higher in group II (7.46 ± 0.37). Mean TAC was greater in group I (1.82 ± 0.19). A statistically significant negative correlation as seen between TAC and salivary pH in S-ECC patients. The study concludes that salivary TAC increases in patients with S-ECC are by that showing a high indirect relationship with salivary pH.

  11. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    International Nuclear Information System (INIS)

    Akahane, Akio; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko

    2011-01-01

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access―the subclavian vein and arm vein―in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1–891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  12. Protocol of an expertise based randomized trial comparing surgical Venae Sectio versus radiological Puncture of Vena Subclavia for insertion of Totally Implantable Access Port in oncological patients

    Directory of Open Access Journals (Sweden)

    Radeleff Boris

    2008-10-01

    Full Text Available Abstract Background Totally Implantable Access Ports (TIAP are being extensively used world-wide and can be expected to gain further importance with the introduction of new neoadjuvant and adjuvant treatments in oncology. Two different techniques for the implantation can be selected: A direct puncture of a central vein and the utilization of a Seldinger device or the surgical Venae sectio. It is still unclear which technique has the optimal benefit/risk ratio for the patient. Design A single-center, expertise based randomized, controlled superiority trial to compare two different TIAP implantation techniques. 100 patients will be included and randomized pre-operatively. All patients aged 18 years or older scheduled for primary elective implantation of a TIAP under local anesthesia who signed the informed consent will be included. The primary endpoint is the primary success rate of the randomized technique. Control Intervention: Venae Sectio will be employed to insert a TIAP by a surgeon; Experimental intervention: Punction of V. Subclavia will be used to place a TIAP by a radiologist. Duration of study: Approximately 10 months, follow up time: 90 days. Organisation/Responsibility The PORTAS 2 – Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The Center of Clinical Trials at the Department of Surgery, University Hospital Heidelberg is responsible for design and conduct of the trial including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI, University of Heidelberg. Trial Registration The trial is registered at ClinicalTrials.gov (NCT00600444.

  13. A comparative study on inhibition of total astragalus saponins and astragaloside IV on TNFR1-mediated signaling pathways in arterial endothelial cells.

    Directory of Open Access Journals (Sweden)

    Qin-she Liu

    Full Text Available Both total astragalus saponins (AST and it's main component astragaloside IV (ASIV have been used in China as cardiovascular protective medicines. However, the anti-inflammatory activities that are beneficial for cardiovascular health have never been compared directly and the molecular mechanisms remain unresolved. This study was conducted to compare the inhibitory effects of these drugs on TNFα-induced cell responses, related signaling pathways, and the underlying mechanisms in mouse arterial endothelial cells.Real-time qRT-PCR was performed to determine the expression of cell adhesion molecule (CAM genes. Immunofluorescent staining was used to detect the nuclear translocation of transcription factor NF-κB-p65. Western Blot analysis was used to identify TNFα-induced NF-κB-p65 phosphorylation, IκBα degradation, and caspase-3 cleavage. Cell surface proteins were isolated and TNFα receptor-1(TNFR1 expression was determined. The results suggest that both AST and ASIV attenuate TNFα-induced up-regulation of CAMs mRNA and upstream nuclear translocation and phosphorylation of NF-κB-p65. However, TNFR1-mediated IκBα degradation, cleavage of caspase-3 and apoptosis were inhibited only by AST. These differences in the actions of AST and ASIV could be explained by the presence of other components in AST, such as ASII and ASIII, which also had an inhibitory effect on TNFR1-induced IκBα degradation. Moreover, AST, but not ASIV, was able to reduce TNFR1 protein level on the cell surface. Furthermore, mechanistic investigation demonstrated that TNFR1-mediated IκBα degradation was reversed by the use of TAPI-0, an inhibitor of TNFα converting enzyme (TACE, suggesting the involvement of TACE in the modulation of surface TNFR1 level by AST.ASIV was not a better inhibitor than AST, at least on the inhibition of TNFα-induced inflammatory responses and TNFR1-mediated signaling pathways in AECs. The inhibitory effect of AST was caused by the

  14. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  15. Comparative study of the discrete velocity and lattice Boltzmann methods for rarefied gas flows through irregular channels

    Science.gov (United States)

    Su, Wei; Lindsay, Scott; Liu, Haihu; Wu, Lei

    2017-08-01

    Rooted from the gas kinetics, the lattice Boltzmann method (LBM) is a powerful tool in modeling hydrodynamics. In the past decade, it has been extended to simulate rarefied gas flows beyond the Navier-Stokes level, either by using the high-order Gauss-Hermite quadrature, or by introducing the relaxation time that is a function of the gas-wall distance. While the former method, with a limited number of discrete velocities (e.g., D2Q36), is accurate up to the early transition flow regime, the latter method (especially the multiple relaxation time (MRT) LBM), with the same discrete velocities as those used in simulating hydrodynamics (i.e., D2Q9), is accurate up to the free-molecular flow regime in the planar Poiseuille flow. This is quite astonishing in the sense that less discrete velocities are more accurate. In this paper, by solving the Bhatnagar-Gross-Krook kinetic equation accurately via the discrete velocity method, we find that the high-order Gauss-Hermite quadrature cannot describe the large variation in the velocity distribution function when the rarefaction effect is strong, but the MRT-LBM can capture the flow velocity well because it is equivalent to solving the Navier-Stokes equations with an effective shear viscosity. Since the MRT-LBM has only been validated in simple channel flows, and for complex geometries it is difficult to find the effective viscosity, it is necessary to assess its performance for the simulation of rarefied gas flows. Our numerical simulations based on the accurate discrete velocity method suggest that the accuracy of the MRT-LBM is reduced significantly in the simulation of rarefied gas flows through the rough surface and porous media. Our simulation results could serve as benchmarking cases for future development of the LBM for modeling and simulation of rarefied gas flows in complex geometries.

  16. Comparative study of the discrete velocity and lattice Boltzmann methods for rarefied gas flows through irregular channels.

    Science.gov (United States)

    Su, Wei; Lindsay, Scott; Liu, Haihu; Wu, Lei

    2017-08-01

    Rooted from the gas kinetics, the lattice Boltzmann method (LBM) is a powerful tool in modeling hydrodynamics. In the past decade, it has been extended to simulate rarefied gas flows beyond the Navier-Stokes level, either by using the high-order Gauss-Hermite quadrature, or by introducing the relaxation time that is a function of the gas-wall distance. While the former method, with a limited number of discrete velocities (e.g., D2Q36), is accurate up to the early transition flow regime, the latter method (especially the multiple relaxation time (MRT) LBM), with the same discrete velocities as those used in simulating hydrodynamics (i.e., D2Q9), is accurate up to the free-molecular flow regime in the planar Poiseuille flow. This is quite astonishing in the sense that less discrete velocities are more accurate. In this paper, by solving the Bhatnagar-Gross-Krook kinetic equation accurately via the discrete velocity method, we find that the high-order Gauss-Hermite quadrature cannot describe the large variation in the velocity distribution function when the rarefaction effect is strong, but the MRT-LBM can capture the flow velocity well because it is equivalent to solving the Navier-Stokes equations with an effective shear viscosity. Since the MRT-LBM has only been validated in simple channel flows, and for complex geometries it is difficult to find the effective viscosity, it is necessary to assess its performance for the simulation of rarefied gas flows. Our numerical simulations based on the accurate discrete velocity method suggest that the accuracy of the MRT-LBM is reduced significantly in the simulation of rarefied gas flows through the rough surface and porous media. Our simulation results could serve as benchmarking cases for future development of the LBM for modeling and simulation of rarefied gas flows in complex geometries.

  17. Comparing statistical and process-based flow duration curve models in ungauged basins and changing rain regimes

    Science.gov (United States)

    Müller, M. F.; Thompson, S. E.

    2016-02-01

    The prediction of flow duration curves (FDCs) in ungauged basins remains an important task for hydrologists given the practical relevance of FDCs for water management and infrastructure design. Predicting FDCs in ungauged basins typically requires spatial interpolation of statistical or model parameters. This task is complicated if climate becomes non-stationary, as the prediction challenge now also requires extrapolation through time. In this context, process-based models for FDCs that mechanistically link the streamflow distribution to climate and landscape factors may have an advantage over purely statistical methods to predict FDCs. This study compares a stochastic (process-based) and statistical method for FDC prediction in both stationary and non-stationary contexts, using Nepal as a case study. Under contemporary conditions, both models perform well in predicting FDCs, with Nash-Sutcliffe coefficients above 0.80 in 75 % of the tested catchments. The main drivers of uncertainty differ between the models: parameter interpolation was the main source of error for the statistical model, while violations of the assumptions of the process-based model represented the main source of its error. The process-based approach performed better than the statistical approach in numerical simulations with non-stationary climate drivers. The predictions of the statistical method under non-stationary rainfall conditions were poor if (i) local runoff coefficients were not accurately determined from the gauge network, or (ii) streamflow variability was strongly affected by changes in rainfall. A Monte Carlo analysis shows that the streamflow regimes in catchments characterized by frequent wet-season runoff and a rapid, strongly non-linear hydrologic response are particularly sensitive to changes in rainfall statistics. In these cases, process-based prediction approaches are favored over statistical models.

  18. Total 2004 results

    International Nuclear Information System (INIS)

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  19. Total 2004 results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  20. Analysis of land use and climate change impacts by comparing river flow records for headwaters and lowland reaches

    Science.gov (United States)

    Fazel, Nasim; Torabi Haghighi, Ali; Kløve, Bjørn

    2017-11-01

    The natural flow regime of rivers has been strongly altered world-wide, resulting in ecosystem degradation and lakes drying up, especially in arid and semi-arid regions. Determining whether this is due mainly to climate change or to water withdrawal for direct human use (e.g. irrigation) is difficult, particularly for saline lake basins where hydrology data are scarce. In this study, we developed an approach for assessing climate and land use change impacts based on river flow records for headwater and lowland reaches of rivers, using the case of Lake Urmia basin, in north-westen Iran. Flow regimes at upstream and downstream stations were studied before and after major dam construction and irrigation projects. Data from 57 stations were used to establish five different time intervals representing 10 different land use development periods (scenarios) for upstream (not impacted) and downstream (impacted) systems. An existing river impact (RI) index was used to assess changes in three main characteristics of flow (magnitude, timing and, intra-annual variability). The results showed that irrigation was by far the main driving force for river flow regime changes in the lake basin. All stations close to the lake and on adjacent plains showed significantly higher impacts of land use change than headwaters. As headwaters are relatively unaffected by agriculture, the non-significant changes observed in headwater flow regimes indicate a minor effect of climate change on river flows in the region. The benefit of the method developed is clear interpretation of results based on river flow records, which is useful in communicating land use and climate change information to decision makers and lake restoration planners.

  1. Application of a method for comparing one-dimensional and two-dimensional models of a ground-water flow system

    International Nuclear Information System (INIS)

    Naymik, T.G.

    1978-01-01

    To evaluate the inability of a one-dimensional ground-water model to interact continuously with surrounding hydraulic head gradients, simulations using one-dimensional and two-dimensional ground-water flow models were compared. This approach used two types of models: flow-conserving one-and-two dimensional models, and one-dimensional and two-dimensional models designed to yield two-dimensional solutions. The hydraulic conductivities of controlling features were varied and model comparison was based on the travel times of marker particles. The solutions within each of the two model types compare reasonably well, but a three-dimensional solution is required to quantify the comparison

  2. Flow Cytometric DNA index, G-band Karyotyping, and Comparative Genomic Hybridization in Detection of High Hyperdiploidy in Childhood Acute Lymphoblastic Leukemia

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Larsen, Jacob; Kristensen, Tim D

    2006-01-01

    High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic hybridiza......High hyperdiploid acute lymphoblastic leukemia in children is related to a good outcome. Because these patients may be stratified to a low-intensity treatment, we have investigated the sensitivity of flow cytometry (FCM), G-band karyotyping (GBK), and high-resolution comparative genomic...

  3. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.

    Science.gov (United States)

    Karidakis, George K; Karachalios, Theofilos

    2015-12-01

    Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. The purpose of this study was to investigate in vivo whether the combination of an oxidized zirconium femoral head on XLPE produces less wear than a ceramic head on XLPE or a ceramic head on conventional polyethylene (CPE) couplings and whether any of these bearing combinations results in higher hip scores. Between 2003 and 2007, we performed 356 total hip arthroplasties in 288 patients; of those, 199 (69.1%) patients (199 hips) were enrolled in what began as a randomized trial. Unfortunately, after the 57(th) patient, the randomization process was halted because of patients' preference for the oxidized zirconium bearing instead of the ceramic after (as they were informed by the consent form), and after that, alternate allocation to the study groups was performed. Hips were allocated into four groups: in Group A, a 28-mm ceramic head on CPE was used; in Group B, a 28-mm ceramic head on XLPE; in Group C, a 28-mm Oxinium head on XLPE; and in Group D, a 32-mm Oxinium head on XLPE. The authors prospectively collected in vivo wear data (linear wear, linear wear rate, volumetric wear, and volumetric wear rate) using PolyWare software. Preoperative and postoperative clinical data, including Harris and Oxford hip scores, were also collected at regular intervals. Of those patients enrolled, 188 (95%) were available for final followup at a minimum of 7 years (mean, 9 years; range, 7-12 years). All bearing surfaces showed a varying high bedding-in effect (plastic deformation of the liner) up to the second postoperative year. At 5 years both oxidized zirconium on XLPE groups showed lower (p zirconium on XLPE groups also showed lower (p zirconium groups were compared, no differences were

  4. Empirical Correlations and CFD Simulations of Vertical Two-Phase Gas-Liquid (Newtonian and Non-Newtonian) Slug Flow Compared Against Experimental Data of Void Fraction

    DEFF Research Database (Denmark)

    Ratkovich, Nicolas Rios; Majumder, S.K.; Bentzen, Thomas Ruby

    2013-01-01

    Gas-Newtonian liquid two-phase flows (TPFs) are presented in several industrial processes (e.g. oil-gas industry). In spite of the common occurrence of these TPFs, the understanding of them is limited compared to single-phase flows. Various studies on TPF focus on developing empirical correlations...... based on large sets of experimental data for void fraction, which have proven accurate for specific conditions for which they were developed limiting their applicability. On the other hand, few studies focus on gas-non-Newtonian liquids TPFs, which are very common in chemical processes. The main reason...... is due to the characterization of the viscosity, which determines the hydraulic regime and flow behaviours of the system. The focus of this study is the analysis of the TPF (slug flow) for Newtonian and non-Newtonian liquids in a vertical pipe in terms of void fraction using computational fluid dynamics...

  5. Pulmonary venous flow index as a predictor of pulmonary vascular resistance variability in congenital heart disease with increased pulmonary flow: a comparative study before and after oxygen inhalation.

    Science.gov (United States)

    Rivera, Ivan Romero; Mendonça, Maria Alayde; Andrade, José Lázaro; Moises, Valdir; Campos, Orlando; Silva, Célia Camelo; Carvalho, Antonio Carlos

    2013-09-01

    There is no definitive and reliable echocardiographic method for estimating the pulmonary vascular resistance (PVR) to differentiate persistent vascular disease from dynamic pulmonary hypertension. The aim of this study was to analyze the relationship between the pulmonary venous blood flow velocity-time integral (VTIpv) and PVR. Eighteen patients (10 females; 4 months to 22 years of age) with congenital heart disease and left to right shunt were studied. They underwent complete cardiac catheterization, including measurements of the PVR and Qp:Qs ratio, before and after 100% oxygen inhalation. Simultaneous left inferior pulmonary venous flow VTIpv was obtained by Doppler echocardiography. The PVR decreased significantly from 5.0 ± 2.6 W to 2.8 ± 2.2 W (P = 0.0001) with a significant increase in the Qp:Qs ratio, from 3.2 ± 1.4 to 4.9 ± 2.4 (P = 0.0008), and the VTIpv increased significantly from 22.6 ± 4.7 cm to 28.1 ± 6.2 cm (P = 0.0002) after 100% oxygen inhalation. VTIpv correlated well with the PVR and Qp:Qs ratio (r = -0.74 and 0.72, respectively). Diagnostic indexes indicated a sensitivity of 86%, specificity of 75%, accuracy of 83%, a positive predictive value of 92% and a negative predictive value of 60%. The VTIpv correlated well with the PVR. The measurement of this index before and after oxygen inhalation may become a useful noninvasive test for differentiating persistent vascular disease from dynamic and flow-related pulmonary hypertension. © 2013, Wiley Periodicals, Inc.

  6. On-line Determination of the Deuterium Abundance in Breath Water Vapour by Flowing Afterglow Mass Spectrometry with Applications to Measurements of Total Body Water

    Czech Academy of Sciences Publication Activity Database

    Španěl, Patrik; Smith, D.

    2001-01-01

    Roč. 15, č. 1 (2001), s. 25-32 ISSN 0951-4198 R&D Project s: GA ČR GA203/00/0632 Grant - others:Royal Society(GB) Joint project Institutional research plan: CEZ:AV0Z4040901 Keywords : flowing afterglow * mass spectrometry * stable isotopes Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.478, year: 2001

  7. Estudio Comparativo con prótesis total de rodilla de alta flexión. [Comparative ­study ­with ­high-flex ­total ­knee­ arthroplasty.

    Directory of Open Access Journals (Sweden)

    Matías Costa Paz

    2014-08-01

    Full Text Available In­tro­duc­ción: El objetivo de este trabajo comparativo fue analizar los resultados funcionales y el rango de movimiento de rodilla entre dos grupos de pacientes con artroplastia total de rodilla: uno utilizando prótesis de alta flexión y el otro con un diseño convencional. Materiales­ y ­Métodos: Setenta y cuatro pacientes fueron operados con artroplastia total de rodilla con prótesis de Zimmer NexGen®, EE.UU. Veintidós (grupo A fueron tratados con diseño de alta flexión. Dos con artritis reumatoide fueron excluidos. Cuarenta y dos pacientes fueron tratados con una convencional, 21 de ellos fueron excluidos, por lo que el grupo B estaba conformado por 21 pacientes. La evaluación funcional se realizó con el Knee Society Score (KSS, el Western Ontario and McMaster Universities osteoathritis index y la escala analógica visual. Resultados: El promedio de flexión máxima preoperatoria fue de 99º en el grupo A y de 106º en el grupo B. En el posoperatorio, el promedio de flexión máxima del grupo A subió a 114º, con un aumento promedio de 15º y, en el grupo B, a 118º con una ganancia promedio de 12º. No hubo diferencias estadísticamente significativas (p <0,05. El puntaje KSS preoperatorio del grupo A fue de 36/48 y mejoró a 90/92. En el grupo B, fue de 46/49 y de 94/90 en el posoperatorio. Conclusión: Las evaluaciones clínicas funcionales y radiológicas son favorables en los dos diseños de prótesis evaluados. Este estudio muestra que no hay diferencias significativas entre el rango de movimiento de una prótesis de alta flexión y una prótesis convencional luego de un año de seguimiento.

  8. Comparative Genomic Analysis of Transgenic Poplar Dwarf Mutant Reveals Numerous Differentially Expressed Genes Involved in Energy Flow

    Directory of Open Access Journals (Sweden)

    Su Chen

    2014-09-01

    Full Text Available In our previous research, the Tamarix androssowii LEA gene (Tamarix androssowii late embryogenesis abundant protein Mrna, GenBank ID: DQ663481 was transferred into Populus simonii × Populus nigra. Among the eleven transgenic lines, one exhibited a dwarf phenotype compared to the wild type and other transgenic lines, named dwf1. To uncover the mechanisms underlying this phenotype, digital gene expression libraries were produced from dwf1, wild-type, and other normal transgenic lines, XL-5 and XL-6. Gene expression profile analysis indicated that dwf1 had a unique gene expression pattern in comparison to the other two transgenic lines. Finally, a total of 1246 dwf1-unique differentially expressed genes were identified. These genes were further subjected to gene ontology and pathway analysis. Results indicated that photosynthesis and carbohydrate metabolism related genes were significantly affected. In addition, many transcription factors genes were also differentially expressed in dwf1. These various differentially expressed genes may be critical for dwarf mutant formation; thus, the findings presented here might provide insight for our understanding of the mechanisms of tree growth and development.

  9. Comparative evaluation of direct thrombin and factor Xa inhibitors with antiplatelet agents under flow and static conditions: an in vitro flow chamber model.

    Directory of Open Access Journals (Sweden)

    Kazuya Hosokawa

    Full Text Available Dabigatran and rivaroxaban are novel oral anticoagulants that specifically inhibit thrombin and factor Xa, respectively. The aim of this study is to elucidate antithrombotic properties of these anticoagulant agents under arterial and venous shear conditions. Whole blood samples treated with dabigatran or rivaroxaban at 250, 500, and 1000 nM, with/without aspirin and AR-C66096, a P2Y12 antagonist, were perfused over a microchip coated with collagen and tissue thromboplastin at shear rates of 240 and 600 s(-1. Fibrin-rich platelet thrombus formation was quantified by monitoring flow pressure changes. Dabigatran at higher concentrations (500 and 1000 nM potently inhibited thrombus formation at both shear rates, whereas 1000 nM of rivaroxaban delayed, but did not completely inhibit, thrombus formation. Dual antiplatelet agents weakly suppressed thrombus formation at both shear rates, but intensified the anticoagulant effects of dabigatran and rivaroxaban. The anticoagulant effects of dabigatran and rivaroxaban were also evaluated under static conditions using thrombin generation (TG assay. In platelet-poor plasma, dabigatran at 250 and 500 nM efficiently prolonged the lag time (LT and moderately reduce peak height (PH of TG, whereas rivaroxaban at 250 nM efficiently prolonged LT and reduced PH of TG. In platelet-rich plasma, however, both anticoagulants efficiently delayed LT and reduced PH of TG. Our results suggest that dabigatran and rivaroxaban may exert distinct antithrombotic effects under flow conditions, particularly in combination with dual antiplatelet therapy.

  10. Total algorithms

    NARCIS (Netherlands)

    Tel, G.

    We define the notion of total algorithms for networks of processes. A total algorithm enforces that a "decision" is taken by a subset of the processes, and that participation of all processes is required to reach this decision. Total algorithms are an important building block in the design of

  11. Comparative study of the two-fluid momentum equations for multi-dimensional bubbly flows: Modification of Reynolds stress

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Jun; Park, Ik Kyu; Yoon, Han Young [Thermal-Hydraulic Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jae, Byoung [School of Mechanical Engineering, Chungnam National University, Daejeon (Korea, Republic of)

    2017-01-15

    Two-fluid equations are widely used to obtain averaged behaviors of two-phase flows. This study addresses a problem that may arise when the two-fluid equations are used for multi-dimensional bubbly flows. If steady drag is the only accounted force for the interfacial momentum transfer, the disperse-phase velocity would be the same as the continuous-phase velocity when the flow is fully developed without gravity. However, existing momentum equations may show unphysical results in estimating the relative velocity of the disperse phase against the continuous-phase. First, we examine two types of existing momentum equations. One is the standard two-fluid momentum equation in which the disperse-phase is treated as a continuum. The other is the averaged momentum equation derived from a solid/ fluid particle motion. We show that the existing equations are not proper for multi-dimensional bubbly flows. To resolve the problem mentioned above, we modify the form of the Reynolds stress terms in the averaged momentum equation based on the solid/fluid particle motion. The proposed equation shows physically correct results for both multi-dimensional laminar and turbulent flows.

  12. Comparative Computed Flow Dynamic Analysis of Different Optimization Techniques in Left Main Either Provisional or Culotte Stenting.

    Science.gov (United States)

    Rigatelli, Gianluca; Dell'Avvocata, Fabio; Zuin, Marco; Giatti, Sara; Duong, Khanh; Pham, Trung; Tuan, Nguyen Si; Vassiliev, Dobrin; Daggubati, Ramesh; Nguyen, Thach

    2017-12-01

    Provisional and culotte are the most commonly used techniques in left main (LM) stenting. The impact of different post-dilation techniques on fluid dynamic of LM bifurcation has not been yet investigated. The aim of this study is to evaluate, by means of computational fluid dynamic analysis (CFD), the impact of different post-dilation techniques including proximal optimization technique (POT), kissing balloon (KB), POT-Side-POT and POT-KB-POT, 2-steps Kissing (2SK) and Snuggle Kissing balloon (SKB) on flow dynamic profile after LM provisional or culotte stenting. We considered an LM-LCA-LCX bifurcation reconstructed after reviewing 100 consecutive patients (mean age 71.4 ± 9.3 years, 49 males) with LM distal disease. The diameters of LAD and LCX were modelled according to the Finnet's law as following: LM 4.5 mm, LAD 3.5 mm, LCX 2.75 mm, with bifurcation angle set up at 55°. Xience third-generation stent (Abbot Inc., USA) was reconstructed and virtually implanted in provisional/cross-over and culotte fashion. POT, KB, POT-side-POT, POT-KB-POT, 2SK and SKB were virtually applied and analyzed in terms of the wall shear stress (WSS). Analyzing the provisional stenting, the 2SK and KB techniques had a statistically significant lower impact on the WSS at the carina, while POT seemed to obtain a neutral effect. In the wall opposite to the carina, the more physiological profile has been obtained by KB and POT with higher WSS value and smaller surface area of the lower WSS. In culotte stenting, at the carina, POT-KB-POT and 2SK had a very physiological profile; while at the wall opposite to the carina, 2SK and POT-KB-POT decreased significantly the surface area of the lower WSS compared to the other techniques. From the fluid dynamic point of view in LM provisional stenting, POT, 2SK and KB showed a similar beneficial impact on the bifurcation rheology, while in LM culotte stenting, POT-KB-POT and 2SK performed slightly better than the other techniques, probably

  13. Microwave-Assisted Sample Treatment in a Fully Automated Flow-Based Instrument: Oxidation of Reduced Technetium Species in the Analysis of Total Technetium-99 in Caustic Aged Nuclear Waste Samples

    International Nuclear Information System (INIS)

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.

    2004-01-01

    An automated flow-based instrument for microwave-assisted treatment of liquid samples has been developed and characterized. The instrument utilizes a flow-through reaction vessel design that facilitates the addition of multiple reagents during sample treatment, removal of the gaseous reaction products, and enables quantitative removal of liquids from the reaction vessel for carryover-free operations. Matrix modification and speciation control chemistries that are required for the radiochemical determination of total 99Tc in caustic aged nuclear waste samples have been investigated. A rapid and quantitative oxidation procedure using peroxydisulfate in acidic solution was developed to convert reduced technetium species to pertechnetate in samples with high content of reducing organics. The effectiveness of the automated sample treatment procedures has been validated in the radiochemical analysis of total 99Tc in caustic aged nuclear waste matrixes from the Hanford site

  14. A comparative study of blood flow in the cerebellum and brainstem between Machado-Joseph disease and olivopontocerebellar atrophy

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Suzuki, Masahiko; Ito Yasuhiko; Iguchi, Yasuyuki; Mori, Yutaka

    2002-01-01

    In recent years, the neurogenic and pathological differences between Machado-Joseph disease (MJD) and sporadic olivopontocerebellar atrophy (OPCA) have been clarified. We performed N-isopropyl-p-[I-123] iodoamphetamine (IMP) SPECT on 9 patients with MJD and 12 patients with OPCA. The blood flow of the cerebellum in the MJD group was significantly decreased than that of the control group (p<0.0001). That of OPCA group was significantly decreased than those of the control and MJD groups (p<0.0001, respectively). The blood flow of the brainstem in the MJD group was significantly decreased than that of the control group (p<0.001). That of OPCA group was significantly decreased than those of the control and MJD groups (p<0.0001, respectively). The blood flow of cerebellum and brainstem in the OPCA group were much decreased than those of MJD group. IMP distribution pattern in MJD patients obviously differed from that of OPCA patients. (author)

  15. A comparative study of the effects of cone-plate and parallel-plate geometries on rheological properties under oscillatory shear flow

    CSIR Research Space (South Africa)

    Yong Song, H

    2017-11-01

    Full Text Available -1 Korea-Australia Rheology Journal A comparative study of the effects of cone-plate and parallel- plate geometries on rheological properties under oscillatory shear flow Hyeong Yong Song1, Reza Salehiyan2, Xiaolei Li1, Seung Hak Lee1 and Kyu Hyun1...

  16. Vertical hydraulic conductivity of a clayey-silt aquitard: accelerated fluid flow in a centrifuge permeameter compared with in situ conditions

    Science.gov (United States)

    Timms, W. A.; Crane, R.; Anderson, D. J.; Bouzalakos, S.; Whelan, M.; McGeeney, D.; Rahman, P. F.; Guinea, A.; Acworth, R. I.

    2014-03-01

    Evaluating the possibility of leakage through low permeability geological strata is critically important for sustainable water supplies, extraction of fuels from strata such as coal beds, and confinement of waste within the earth. Characterizing low or negligible flow rates and transport of solutes can require impractically long periods of field or laboratory testing, but is necessary for evaluations over regional areas and over multi-decadal timescales. The current work reports a custom designed centrifuge permeameter (CP) system, which can provide relatively rapid and reliable hydraulic conductivity (K) measurement compared to column permeameter tests at standard gravity (1g). Linear fluid velocity through a low K porous sample is linearly related to g-level during a CP flight unless consolidation or geochemical reactions occur. The CP module is designed to fit within a standard 2 m diameter, geotechnical centrifuge with a capacity for sample dimensions of 30 to 100 mm diameter and 30 to 200 mm in length. At maximum RPM the resultant centrifugal force is equivalent to 550g at base of sample or a total stress of ~2 MPa. K is calculated by measuring influent and effluent volumes. A custom designed mounting system allows minimal disturbance of drill core samples and a centrifugal force that represents realistic in situ stress conditions is applied. Formation fluids were used as influent to limit any shrink-swell phenomena which may alter the resultant K value. Vertical hydraulic conductivity (Kv) results from CP testing of core from the sites in the same clayey silt formation varied (10-7 to 10-9 m s-1, n = 14) but higher than 1g column permeameter tests of adjacent core using deionized water (10-9 to 10-11 m s-1, n = 7). Results at one site were similar to in situ Kv values (3 × 10-9 m s-1) from pore pressure responses within a 30 m clayey sequence in a homogenous area of the formation. Kv sensitivity to sample heterogeneity was observed, and anomalous flow via

  17. Comparing the International Knowledge Flow of China’s Wind and Solar Photovoltaic (PV Industries: Patent Analysis and Implications for Sustainable Development

    Directory of Open Access Journals (Sweden)

    Yuan Zhou

    2018-06-01

    Full Text Available Climate-relevant technologies, like wind and solar energy, are crucial for mitigating climate change and for achieving sustainable development. Recent literature argues that Chinese solar firms play more active roles in international knowledge flows, which may better explain their success in international markets when compared to those of Chinese wind firms; however, empirical evidence remains sparse. This study aims to explore to what extent and how do the international knowledge flows differ between China’s wind and solar photovoltaic (PV industries? From a network perspective, this paper develops a three-dimensional framework to compare the knowledge flows in both explicit and tacit dimensions: (i inter-country explicit knowledge clusters (by topological clustering of patent citation network; (ii inter-firm explicit knowledge flow (patent citation network of key firms; and, (iii inter-firm tacit knowledge flow (by desktop research and interviews. The results show that China’s PV industry has stronger international knowledge linkages in terms of knowledge clustering and explicit knowledge flow, but the wind power industry has a stronger tacit knowledge flow. Further, this study argues that the differences of global knowledge links between China’s wind and solar PV industries may be caused by technology characteristics, market orientation, and policy implementation. This suggests that these industries both have strong connections to global knowledge networks, but they may involve disparate catch-up pathways that concern follower-modes and leader-modes. These findings are important to help us understand how China can follow sustainable development pathways in the light of climate change.

  18. A comparative study of artificial neural network, adaptive neuro fuzzy inference system and support vector machine for forecasting river flow in the semiarid mountain region

    Science.gov (United States)

    He, Zhibin; Wen, Xiaohu; Liu, Hu; Du, Jun

    2014-02-01

    Data driven models are very useful for river flow forecasting when the underlying physical relationships are not fully understand, but it is not clear whether these data driven models still have a good performance in the small river basin of semiarid mountain regions where have complicated topography. In this study, the potential of three different data driven methods, artificial neural network (ANN), adaptive neuro fuzzy inference system (ANFIS) and support vector machine (SVM) were used for forecasting river flow in the semiarid mountain region, northwestern China. The models analyzed different combinations of antecedent river flow values and the appropriate input vector has been selected based on the analysis of residuals. The performance of the ANN, ANFIS and SVM models in training and validation sets are compared with the observed data. The model which consists of three antecedent values of flow has been selected as the best fit model for river flow forecasting. To get more accurate evaluation of the results of ANN, ANFIS and SVM models, the four quantitative standard statistical performance evaluation measures, the coefficient of correlation (R), root mean squared error (RMSE), Nash-Sutcliffe efficiency coefficient (NS) and mean absolute relative error (MARE), were employed to evaluate the performances of various models developed. The results indicate that the performance obtained by ANN, ANFIS and SVM in terms of different evaluation criteria during the training and validation period does not vary substantially; the performance of the ANN, ANFIS and SVM models in river flow forecasting was satisfactory. A detailed comparison of the overall performance indicated that the SVM model performed better than ANN and ANFIS in river flow forecasting for the validation data sets. The results also suggest that ANN, ANFIS and SVM method can be successfully applied to establish river flow with complicated topography forecasting models in the semiarid mountain regions.

  19. A comparative study of voiding in rat and guinea pig: simultaneous measurement of flow rate and pressure

    NARCIS (Netherlands)

    E. van Asselt (Els); J.M. Groen (Jan); R. van Mastrigt (Ron)

    1995-01-01

    textabstractIn this study, the voiding phase of the micturition cycle in the anesthetized rat and guinea pig is analyzed. In both animals, voiding is characterized by an increase in intravesical pressure and then a decrease, which is accompanied by flow through the urethra and emission of urine. An

  20. How we can measure the non-driving-task engagement in automated driving: Comparing flow experience and workload.

    Science.gov (United States)

    Ko, Sang Min; Ji, Yong Gu

    2018-02-01

    In automated driving, a driver can completely concentrate on non-driving-related tasks (NDRTs). This study investigated the flow experience of a driver who concentrated on NDRTs and tasks that induce mental workload under conditional automation. Participants performed NDRTs under different demand levels: a balanced demand-skill level (fit condition) to induce flow, low-demand level to induce boredom, and high-demand level to induce anxiety. In addition, they performed the additional N-Back task, which artificially induces mental workload. The results showed participants had the longest reaction time when they indicated the highest flow score, and had the longest gaze-on time, road-fixation time, hands-on time, and take-over time under the fit condition. Significant differences were not observed in the driver reaction times in the fit condition and the additional N-Back task, indicating that performing NDRTs that induce a high flow experience could influence driver reaction time similar to performing tasks with a high mental workload. Copyright © 2017. Published by Elsevier Ltd.

  1. A comparative study on the flow experience in web-based and text-based interaction environments.

    Science.gov (United States)

    Huang, Li-Ting; Chiu, Chen-An; Sung, Kai; Farn, Cheng-Kiang

    2011-01-01

    The purpose of this study was to explore a substantial phenomenon related to flow experiences (immersion) in text-based interaction systems. Most previous research emphasizes the effects of challenge/skill, focused attention, telepresence, web characteristics, and systems' interface design on users' flow experiences in online environments. However, text-based interaction systems without telepresence features and web characteristics still seem to create opportunities for flow experience. To explore this phenomenon, this study incorporates subject involvement and interpersonal interaction as critical antecedents into the model of flow experience, as well as considers the existence of telepresence. Results reveal that subject involvement, interpersonal interaction, and interactivity speed are critical to focused attention, which enhances users' immersion. With regard to the effect of telepresence, the perceived attractiveness of the interface is a significant facilitator determining users' immersion in web-based, rather than in text-based, interaction environments. Interactivity speed is unrelated to immersion in both web-based and text-based interaction environments. The influence of interpersonal involvement is diminished in web-based interaction environments. The implications and limitations of this study are discussed.

  2. A comparative study of applying Mason’s Rule in the case of flow-graphs and bond-graphs

    Directory of Open Access Journals (Sweden)

    Adriana Grava

    2009-05-01

    Full Text Available The paper presents two methods to analyzethe electric circuits using the flow-graphs and thebond-graphs studying the differences between thesemethods.As it can be noticed, the two methods are totallydifferent; their common point being Mason’s rule thatis applied in both cases but it is applied differently foreach type of graphs.

  3. Comparative Analysis of γ-Oryzanol, β-Glucan, Total Phenolic Content and Antioxidant Activity in Fermented Rice Bran of Different Varieties.

    Science.gov (United States)

    Jung, Tae-Dong; Shin, Gi-Hae; Kim, Jae-Min; Choi, Sun-Il; Lee, Jin-Ha; Lee, Sang Jong; Park, Seon Ju; Woo, Koan Sik; Oh, Sea Kwan; Lee, Ok-Hawn

    2017-06-03

    Rice bran, a by-product derived from processing rice, is a rich source of bioactive compounds. Recent studies have suggested that the fermentation can improve their biological activities. This study aimed to determined the level of γ-oryzanol, β-glucan and total phenol contents of fermented rice bran from 21 Korean varieties, as well as to evaluate their antioxidant activities. We also assessed the validation of the analytical method for determining γ-oryzanol content in fermented rice brans. Among the fermented rice brans, the Haedam rice bran contained the highest level of total phenol content (156.08 mg gallic acid equivalents/g), DPPH (2,2-diphenyl-1-picrylhydrazyl) radical scavenging activity (71.30%) and ORAC (Oxygen radical absorbance capacity) value (1101.31 μM trolox equivalents/g). Furthermore, the fermented Migwang rice bran showed the highest level of γ-oryzanol content (294.77 ± 6.74 mg/100 g).

  4. Effect of early supervised progressive resistance training compared to unsupervised home-based exercise after fast-track total hip replacement applied to patients with preoperative functional limitations

    DEFF Research Database (Denmark)

    Mikkelsen, L R; Mechlenburg, I; Søballe, K

    2014-01-01

    OBJECTIVE: To examine if 2 weekly sessions of supervised progressive resistance training (PRT) in combination with 5 weekly sessions of unsupervised home-based exercise is more effective than 7 weekly sessions of unsupervised home-based exercise in improving leg-extension power of the operated leg...... 10 weeks after total hip replacement (THR) in patients with lower pre-operative function. METHOD: A total of 73 patients scheduled for THR were randomised (1:1) to intervention group (IG, home based exercise 5 days/week and PRT 2 days/week) or control group (CG, home based exercise 7 days...... of the operated leg, at the primary endpoint 10 weeks after surgery in THR patients with lower pre-operative function. TRIAL REGISTRATION: NCT01214954....

  5. Total energy intake may be more associated with glycemic control compared to each proportion of macronutrients in the korean diabetic population.

    Science.gov (United States)

    Kang, Hye Mi; Kim, Dong-Jun

    2012-08-01

    Major macronutrients for energy intake vary among countries and cultures. Carbohydrates, including rice, are the major component of daily energy intake in Korea. The aim of this study was to examine the association of daily energy intake or each proportion of macronutrients, especially carbohydrates, with glycemic control in diabetic Koreans. A total of 334 individuals with diabetes (175 men, age 57.4±0.8 years; 159 women, age 60.9±0.9 years) who participated in the 2005 Korean National Health and Nutrition Examination Survey were examined. Glycemic control was categorized based on concentration of glycated hemoglobin (HbA1c; HbA1c ≤6.5%; 6.6% to 8.0%; ≥8.1%). Dietary intake was assessed by using a 24-recall item questionnaire. High total energy intake was associated with poor glycemic control (HbA1c ≤6.5%, 1,824±75 kcal; 6.6% to 8.0%, 1,990±57 kcal; ≥8.1%, 2,144±73 kcal; P value for trend=0.002). Each proportion of protein, fat, or carbohydrate was not associated with glycemic control. Even after adjusting for several parameters, the association of daily energy intake with glycemic control still persisted. Total energy intake may be more closely related to glycemic control than each proportionof macronutrients in Korean diabetics.

  6. Comparative study of nutritional constituents and the mercury total constituents in fishes commercialized at the city of Cananeia, at the coastal of Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Nascimento, Soraia M.; Farias, Luciana A.; Curcho, Michel R.M.; Favaro, Deborah I.T.; Braga, Elisabete S.

    2009-01-01

    Aiming the determination of the Hg concentration and the As, Cr and Zn trace elements, four commercial available and frequently consumable fishes by the Cananeia, Sao Paulo, Brazil, were analysed. A total of 53 samples were evaluated as follows: jew fish (Micropogonias furnieri), hake (Macrodon ancylodon), perch (Centropomus undecimalis), and grey mullet (Mugil platanus), all acquired at local fishmonger. The atomic absorption and neutron activation analysis techniques were used for the determination of Hg total levels and trace elements respectively. The trace elements presented large concentration variation among the same specie and the species performed as well. The jew fish presented levels superior to 1000 μg kg -1 for the most individuals analysed and the perch presented chromium levels exceeding the limit of 0.10 mg kg -1 for some individuals. The level of Zn presented values below 50 mg kg -1 established by the Brazilian legislation for all species. The Zn total contents among all species presented values bellow the limits of the Brazilian legislation (500 μg kg -1 for the predator species and 1000 μg kg -1 for the predator species)

  7. Total Energy Intake May Be More Associated with Glycemic Control Compared to Each Proportion of Macronutrients in the Korean Diabetic Population

    Directory of Open Access Journals (Sweden)

    Hye Mi Kang

    2012-08-01

    Full Text Available BackgroundMajor macronutrients for energy intake vary among countries and cultures. Carbohydrates, including rice, are the major component of daily energy intake in Korea. The aim of this study was to examine the association of daily energy intake or each proportion of macronutrients, especially carbohydrates, with glycemic control in diabetic Koreans.MethodsA total of 334 individuals with diabetes (175 men, age 57.4±0.8 years; 159 women, age 60.9±0.9 years who participated in the 2005 Korean National Health and Nutrition Examination Survey were examined. Glycemic control was categorized based on concentration of glycated hemoglobin (HbA1c; HbA1c ≤6.5%; 6.6% to 8.0%; ≥8.1%. Dietary intake was assessed by using a 24-recall item questionnaire.ResultsHigh total energy intake was associated with poor glycemic control (HbA1c ≤6.5%, 1,824±75 kcal; 6.6% to 8.0%, 1,990±57 kcal; ≥8.1%, 2,144±73 kcal; P value for trend=0.002. Each proportion of protein, fat, or carbohydrate was not associated with glycemic control. Even after adjusting for several parameters, the association of daily energy intake with glycemic control still persisted.ConclusionTotal energy intake may be more closely related to glycemic control than each proportionof macronutrients in Korean diabetics.

  8. Measuring arrangement for simultaneous and continuous determination of the total and radioactive amounts of reactive matters in flowing inert gases. Pt. 1

    International Nuclear Information System (INIS)

    Figge, K.; Martinen, H.; Schulz, W.

    1976-01-01

    In order to investigate the metabolism behaviour of radiocarbon-labelled substances, a special apparatus has been designed which enables a fully automatic as well as continuous and simultaneous determination of the total and the 14 C-labelled carbon dioxide (CO 2 ) in the respiratory air of small animals. The CO 2 which is exhaled by the experimental animals is absorbed quantitatively in a novel absorber-scintillator cocktail. The quantity of combined total CO 2 is then determined by measuring the specific conductivity whereas the amount of radioactive CO 2 is assessed via scintillation measurement. The measuring accuracy achieved is around 10 N cm 3 or about 5 nCi, whereas the CO 2 recovery is above 98%. In addition to the recording in a linear recorder, the data are transferred to punching tapes and can be evaluated in an EDP unit. (orig.) [de

  9. Effects of policosanol on borderline to mildly elevated serum total cholesterol levels: a prospective, double-blind, placebo-controlled, parallel-group, comparative study

    Directory of Open Access Journals (Sweden)

    Gladys Castaño, PhD

    2003-09-01

    Full Text Available Background: Hypercholesterolemia is a major risk factor for coronary heart disease. Clinical studies have shown that lowering elevated serum cholesterol levels, particularly low-density lipoprotein cholesterol (LDL-C, is beneficial for patients with borderline to mildly elevated serum total cholesterol (TC levels (5.0–6.0 mmol/L. Policosanol is a cholesterol-lowering drug made from purified sugar cane wax. The therapeutic range of policosanol is 5 to 20 mg/d. Objective: This study investigated the efficacy and tolerability of policosanol 5 mg/d in patients with borderline to mildly elevated serum TC levels. Methods: This 14-week, single-center, prospective, double-blind, placebo-controlled, parallel-group, comparative study was conducted in men and women aged 25 to 75 years with a serum TC level ≥4.8 to <6.0 mmol/L. After a 6-week run-in period in which patients were placed on therapeutic lifestyle changes, in particular a cholesterol-lowering diet, patients were randomly assigned to receive policosanol 5-mg tablets or placebo tablets once daily with the evening meal for 8 weeks, and the diet was continued throughout the study. Lipid profile variables, safety indicators, adverse events (AEs, and compliance with study medications were assessed. Results: One hundred patients (71 women, 29 men; mean [SD] age, 52 [10] years entered the study after the dietary run-in period. After 8 weeks of treatment, the mean (SD serum LDL-C level decreased significantly in the policosanol group (P<0.001 vs baseline and placebo from 3.57 (0.30 mmol/L to 2.86 (0.41 mmol/L (change, −19.9%. Significantly more patients in the policosanol group (42 patients [84%] achieved a ≥15% decrease in serum LDL-C than in the placebo group (2 patients [4%] (P<0.001. Also in the policosanol group, the mean (SD serum TC level decreased significantly, from 5.20 (0.22 mmol/L to 4.56 (0.44 mmol/L (P<0.001 vs baseline and placebo (change, −12.3%; the mean (SD triglyceride (TG

  10. Totally James

    Science.gov (United States)

    Owens, Tom

    2006-01-01

    This article presents an interview with James Howe, author of "The Misfits" and "Totally Joe". In this interview, Howe discusses tolerance, diversity and the parallels between his own life and his literature. Howe's four books in addition to "The Misfits" and "Totally Joe" and his list of recommended books with lesbian, gay, bisexual, transgender,…

  11. Fluid Flow Patterns During Production from Gas Hydrates in the Laboratory compared to Field Settings: LARS vs. Mallik

    Science.gov (United States)

    Strauch, B.; Heeschen, K. U.; Priegnitz, M.; Abendroth, S.; Spangenberg, E.; Thaler, J.; Schicks, J. M.

    2015-12-01

    The GFZ's LArge Reservoir Simulator LARS allows for the simulation of the 2008 Mallik gas hydrate production test and the comparison of fluid flow patterns and their driving forces. Do we see the gas flow pattern described for Mallik [Uddin, M. et al., J. Can. Petrol Tech, 50, 70-89, 2011] in a pilot scale test? If so, what are the driving forces? LARS has a network of temperature sensors and an electric resistivity tomography (ERT) enabling a good spatial resolution of gas hydrate occurrences, water and gas distribution, and changes in temperature in the sample. A gas flow meter and a water trap record fluid flow patterns and a backpressure valve has controlled the depressurization equivalent to the three pressure stages (7.0 - 5.0 - 4.2 MPa) applied in the Mallik field test. The environmental temperature (284 K) and confining pressure (13 MPa) have been constant. The depressurization induced immediate endothermic gas hydrate dissociation until re-establishment of the stability conditions by a consequent temperature decrease. Slight gas hydrate dissociation continued at the top and upper lateral border due to the constant heat input from the environment. Here transport pathways were short and permeability higher due to lower gas hydrate saturation. At pressures of 7.0 and 5.0 MPa the LARS tests showed high water flow rates and short irregular spikes of gas production. The gas flow patterns at 4.2 MPa and 3.0MPa resembled those of the Mallik test. In LARS the initial gas surges overlap with times of hydrate instability while water content and lengths of pathways had increased. Water production was at a minimum. A rapidly formed continuous gas phase caused the initial gas surges and only after gas hydrate dissociation decreased to a minimum the single gas bubbles get trapped before slowly coalescing again. In LARS, where pathways were short and no additional water was added, a transport of microbubbles is unlikely to cause a gas surge as suggested for Mallik.

  12. EBITDA/EBIT and cash flow based ICRs: A comparative approach in the agro-food system in Italy

    Directory of Open Access Journals (Sweden)

    Mattia Iotti

    2012-05-01

    Full Text Available The interest coverage ratios (ICRs are used to quantify the ability of firms to pay financial debts; ICRs are then considered by banks such as covenants in the financing term sheet, and are used by researchers and the rating agencies to estimate the probability of default of firms. Typically, ICRs calculation is based on profit margins, such as EBITDA and EBIT; EBITDA and EBIT approximate, but do not directly express, cash flows available to pay financial debts. The article aims to evaluate whether there are significant differences in results using ICRs based on EBITDA or EBIT and ICRs based on different definitions of cash flow (CF. The application is made to a sample of firms characterized by high absorption of capital operating in the Italian agro-food sector. The article highlights that there are statistically significant differences using ICRs EBITDA and EBIT based and ICRs based on different CF definitions.

  13. Comparative Evaluation of the Effect of Menstruation, Pregnancy and Menopause on Salivary Flow Rate, pH and Gustatory Function

    Science.gov (United States)

    Shetty, Vishwaprakash; Dave, Aparna; Arora, Manpreet; Hans, Vibha; Madan, Ajay

    2014-01-01

    Objective: There are five situations in a women’s life during which hormone fluctuations make them more susceptible to oral health problems – during puberty, at certain points in the monthly menstrual cycle, when using birth control pills, during pregnancy, and at menopause. The present study aimed at evaluating the effect of menstruation, pregnancy and menopause on salivary flow rate, pH and gustatory function. Materials and Methods: The study was carried out on 120 patients including 30 controls (with normal menstrual cycle of 28 to 30 d) and 90 cases (30 patients within three days of menstruation, 30 pregnant and 30 postmenopausal). Paraffin-stimulated saliva samples were obtained by expectoration to calculate salivary flow rate, pH was measured electrometically and patients were prospectively evaluated for gustatory function. Then, whole mouth taste test was performed in which the quality identification and intensity ratings of taste solutions were measured. Results: No statistically significant difference was found between the groups with respect to salivary flow rate but pH values were significantly lower in post menopausal women (pwomen than intensity of taste perception for other tastes (pwomen reported change in their dietary habits as all of them expressed liking for sweeter food. Conclusion: Reduced salivary flow rate and pH in postmen­opausal women may make them more prone to the occurrence of oral health problems. Also, pregnant and postmenopausal women appeared to have a reduced perception of sucrose, which can alter eating habits, such as intake of more sweet foods whereas no significant difference is observed in taste perception of NaCl, citric acid and quinine hydrochloride between the subjects. PMID:25478455

  14. Comparative Evaluation of the Effect of Menstruation, Pregnancy and Menopause on Salivary Flow Rate, pH and Gustatory Function.

    Science.gov (United States)

    Saluja, Pulin; Shetty, Vishwaprakash; Dave, Aparna; Arora, Manpreet; Hans, Vibha; Madan, Ajay

    2014-10-01

    There are five situations in a women's life during which hormone fluctuations make them more susceptible to oral health problems - during puberty, at certain points in the monthly menstrual cycle, when using birth control pills, during pregnancy, and at menopause. The present study aimed at evaluating the effect of menstruation, pregnancy and menopause on salivary flow rate, pH and gustatory function. The study was carried out on 120 patients including 30 controls (with normal menstrual cycle of 28 to 30 d) and 90 cases (30 patients within three days of menstruation, 30 pregnant and 30 postmenopausal). Paraffin-stimulated saliva samples were obtained by expectoration to calculate salivary flow rate, pH was measured electrometically and patients were prospectively evaluated for gustatory function. Then, whole mouth taste test was performed in which the quality identification and intensity ratings of taste solutions were measured. No statistically significant difference was found between the groups with respect to salivary flow rate but pH values were significantly lower in post menopausal women (pwomen than intensity of taste perception for other tastes (pwomen reported change in their dietary habits as all of them expressed liking for sweeter food. Reduced salivary flow rate and pH in postmen-opausal women may make them more prone to the occurrence of oral health problems. Also, pregnant and postmenopausal women appeared to have a reduced perception of sucrose, which can alter eating habits, such as intake of more sweet foods whereas no significant difference is observed in taste perception of NaCl, citric acid and quinine hydrochloride between the subjects.

  15. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups.

    Science.gov (United States)

    Muddugangadhar, B C; Sangur, Rajashekar; Rudraprasad, I V; Nandeeshwar, D B; Kumar, B H Dhanya

    2015-01-01

    This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics.

  16. A clinical study to compare between resting and stimulated whole salivary flow rate and pH before and after complete denture placement in different age groups

    Science.gov (United States)

    Muddugangadhar, B. C.; Sangur, Rajashekar; Rudraprasad, I. V.; Nandeeshwar, D. B.; Kumar, B. H. Dhanya

    2015-01-01

    Purpose: This study compared the flow rate and pH of resting (unstimulated) and stimulated whole saliva before and after complete denture placement in different age groups. Materials and Methods: Fifty healthy, non-medicated edentulous individuals of different age groups requiring complete denture prostheses were selected from the outpatient department. The resting (unstimulated) and stimulated whole saliva and pH were measured at three stages i.e., i)Before complete denture placement;ii)Immediately after complete denture placement; andiii)After 2 to 3 months of complete denture placement. Saliva production was stimulated by chewing paraffin wax. pH was determined by using a digital pH meter. Results: Statistically significant differences were seen in resting(unstimulated) and stimulated whole salivary flow rate and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No statistically significant differences were found between the different age groups in resting (unstimulated) as well as stimulated whole salivary flow rate and pH. Conclusion: Stimulated whole salivary flow rates and pH were significantly higher than resting (unstimulated) whole salivary flow rates and pH obtained before, immediately after, and after 2 to 3 months of complete denture placement. No age related variations in whole salivary flow rate and pH were observed in healthy, non-medicated individuals. Clinical Implications: The assessment of salivary flow rate, pH in different age groups is of prognostic value, which is an important aspect to be considered in the practice of removable prosthodontics. PMID:26929540

  17. A comparative evaluation of the in vitro penetration performance of the improved Crest Complete toothbrush versus the Colgate Total toothbrush and the Oral-B Advantage toothbrush.

    Science.gov (United States)

    Volpenhein, D W; Hartman, W L

    1996-01-01

    Removal of plaque and debris from interproximal surfaces during toothbrushing has generally been difficult to achieve, in large part because traditional flat-bristled toothbrushes do not offer good interproximal penetration. As a result, a number of varying bristle designs have been developed, with the rippled-design brush shown to be particularly effective at removing interproximal plaque. Recently, an existing rippled brush, the original Crest Complete, was modified to offer longer rippled outer tufts to clean along the gumline more effectively. Therefore, this study evaluated the overall and gumline interproximal penetration of three bristle designs: rippled, raised pattern (Improved Crest Complete); and two multi-level patterns (Colgate Total and Oral-B Advantage). The study used a previously reported in vitro model for determining interproximal penetration of manual toothbrushes (J Clin Dent 5:27-33, 1994). In order to effectively mimic the in-use characteristics of toothbrushing, this model is based on analysis of videotaped consumer brushing habits, tooth morphology, and in vivo plaque tenacity characteristics, and uses the three most predominantly used brushing techniques (circular, up-and-down, and back-and-forth with the brush held at both 45 degrees and 90 degrees to the tooth surface). In addition, the model's brush stroke length, brush force, and brush speed are likewise based on an analysis of consumer brushing patterns. The results of this study indicate that the Improved Crest Complete with longer rippled outer bristles provided significantly superior (p Colgate Total and Oral-B Advantage brushes.

  18. Comparative Analysis of γ-Oryzanol, β-Glucan, Total Phenolic Content and Antioxidant Activity in Fermented Rice Bran of Different Varieties

    Directory of Open Access Journals (Sweden)

    Tae-Dong Jung

    2017-06-01

    Full Text Available Rice bran, a by-product derived from processing rice, is a rich source of bioactive compounds. Recent studies have suggested that the fermentation can improve their biological activities. This study aimed to determined the level of γ-oryzanol, β-glucan and total phenol contents of fermented rice bran from 21 Korean varieties, as well as to evaluate their antioxidant activities. We also assessed the validation of the analytical method for determining γ-oryzanol content in fermented rice brans. Among the fermented rice brans, the Haedam rice bran contained the highest level of total phenol content (156.08 mg gallic acid equivalents/g, DPPH (2,2-diphenyl-1-picrylhydrazyl radical scavenging activity (71.30% and ORAC (Oxygen radical absorbance capacity value (1101.31 μM trolox equivalents/g. Furthermore, the fermented Migwang rice bran showed the highest level of γ-oryzanol content (294.77 ± 6.74 mg/100 g.

  19. UBC-Nepal expedition: markedly lower cerebral blood flow in high-altitude Sherpa children compared with children residing at sea level.

    Science.gov (United States)

    Flück, Daniela; Morris, Laura E; Niroula, Shailesh; Tallon, Christine M; Sherpa, Kami T; Stembridge, Mike; Ainslie, Philip N; McManus, Ali M

    2017-10-01

    Developmental cerebral hemodynamic adaptations to chronic high-altitude exposure, such as in the Sherpa population, are largely unknown. To examine hemodynamic adaptations in the developing human brain, we assessed common carotid (CCA), internal carotid (ICA), and vertebral artery (VA) flow and middle cerebral artery (MCA) velocity in 25 (9.6 ± 1.0 yr old, 129 ± 9 cm, 27 ± 8 kg, 14 girls) Sherpa children (3,800 m, Nepal) and 25 (9.9 ± 0.7 yr old, 143 ± 7 cm, 34 ± 6 kg, 14 girls) age-matched sea level children (344 m, Canada) during supine rest. Resting gas exchange, blood pressure, oxygen saturation and heart rate were assessed. Despite comparable age, height and weight were lower (both P sea level children. Mean arterial pressure, heart rate, and ventilation were similar, whereas oxygen saturation (95 ± 2 vs. 99 ± 1%, P sea level children. This was reflected in a lower ICA flow (283 ± 108 vs. 333 ± 56 ml/min, P = 0.05), VA flow (78 ± 26 vs. 118 ± 35 ml/min, P sea level children (425 ± 92 vs. 441 ± 81 ml/min, P = 0.52). Scaling flow and oxygen uptake for differences in vessel diameter and body size, respectively, led to the same findings. A lower cerebral blood flow in Sherpa children may reflect specific cerebral hemodynamic adaptations to chronic hypoxia. NEW & NOTEWORTHY Cerebral blood flow is lower in Sherpa children compared with children residing at sea level; this may reflect a cerebral hemodynamic pattern, potentially due to adaptation to a hypoxic environment. Copyright © 2017 the American Physiological Society.

  20. Creating Compact Comparative Health Care Information: What Are the Key Quality Attributes to Present for Cataract and Total Hip or Knee Replacement Surgery?

    NARCIS (Netherlands)

    Damman, O.C.; Spreeuwenberg, P.; Rademakers, J.; Hendriks, M.

    2012-01-01

    Background. The recent emphasis on providing comparative health care data to the public has resulted in a large amount of online information. To focus on the most essential attributes, insight is needed into which attributes are actually considered by consumers. Objective. To assess which attributes

  1. Creating compact comparative health care information: what are the key quality attributes to present for cataract and total hip or knee replacement surgery?

    NARCIS (Netherlands)

    Damman, O.C.; Spreeuwenberg, P.; Rademakers, J.; Hendriks, M.

    2012-01-01

    Background. The recent emphasis on providing comparative health care data to the public has resulted in a large amount of online information. To focus on the most essential attributes, insight is needed into which attributes are actually considered by consumers. Objective. To assess which attributes

  2. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Schizophrenia Spectrum Disorders in a Danish 22q11.2 Deletion Syndrome Cohort Compared to the Total Danish Population-A Nationwide Register Study

    DEFF Research Database (Denmark)

    Vangkilde, Anders; Olsen, Line; Hoeffding, Louise K

    2016-01-01

    OBJECTIVE: Cross-sectional studies have shown associations between 22q11.2 deletion syndrome and schizophrenia. However, large-scale prospective studies have been lacking. We, therefore, conducted the first large-scale population based study on the risk of being diagnosed with schizophrenia...... in persons identified with 22q11.2 deletion syndrome. METHODS: Danish nationwide registers were linked to establish a cohort consisting of all Danish citizens born during 1955-2004 and the cohort was followed from January 1, 1994 until December 31, 2013. Data were analyzed using survival analyses...... and adjusted for calendar year, age, sex, and parental mental health history. RESULTS: A total of 156 individuals with 22q11.2 deletion syndrome were identified, out of which 6 individuals were diagnosed with schizophrenia spectrum disorders following identification with 22q11 deletion syndrome. Identified...

  4. A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique.

    Science.gov (United States)

    Øhrn, Frank-David; Van Leeuwen, Justin; Tsukanaka, Masako; Röhrl, Stephan M

    2018-05-09

    Background and purpose - There is some concern regarding the revision rate of the Vanguard CR TKA in 1 registry, and the literature is ambiguous about the efficacy of patient-specific positioning guides (PSPGs). The objective of this study was to investigate the stability of the cemented Vanguard CR Total Knee using 2 different surgical techniques. Our hypothesis was that there is no difference in migration when implanting the Vanguard CR with either PSPGs or conventional technique. We hereby present a randomized controlled trial of 2-year follow-up with radiostereometric analysis (RSA). Patients and methods - 40 TKAs were performed between 2011 and 2013 with either PSPGs or the conventional technique and 22 of these were investigated with RSA. Results - The PSPG (8 knees) and the conventional (14 knees) groups had a mean maximum total point motion (MTPM) (95% CI) of 0.83 (0.48-1.18) vs. 0.70 (0.43-0.97) mm, 1.03 (0.60-1.43) vs. 0.86 (0.53-1.19), and 1.46 (1.07-1.85) vs. 0.80 (0.52-1.43) at 3, 12, and 24 months respectively (p = 0.1). 5 implants had either an MTPM >1.6 mm at 12 months and/or a migration of more than 0.2 mm between 1- and 2-year follow-ups. 2 of these also had a peripheral subsidence of more than 0.6 mm at 2 years. Interpretation - 5 implants (3 in the PSPG group) were found to be at risk of later aseptic loosening. The PSPG group continuously migrated between 12 and 24 months. The conventional group had an initial high migration between postoperative and 3 months, but seemed more stable after 1 year. Although the difference was not statistically significant, we think the migration in the PSPG group is of some concern.

  5. Microfluidic Manufacturing of Polymeric Nanoparticles: Comparing Flow Control of Multiscale Structure in Single-Phase Staggered Herringbone and Two-Phase Reactors.

    Science.gov (United States)

    Xu, Zheqi; Lu, Changhai; Riordon, Jason; Sinton, David; Moffitt, Matthew G

    2016-12-06

    We compare the microfluidic manufacturing of polycaprolactone-block-poly(ethylene oxide) (PCL-b-PEO) nanoparticles (NPs) in a single-phase staggered herringbone (SHB) mixer and in a two-phase gas-liquid segmented mixer. NPs generated from two different copolymer compositions in both reactors and at three different flow rates, along with NPs generated using a conventional bulk method, are compared with respect to morphologies, dimensions, and internal crystallinities. Our work, the first direct comparison between alternate microfluidic NP synthesis methods, shows three key findings: (i) NP morphologies and dimensions produced in the bulk are different from those produced in a microfluidic mixer, whereas NP crystallinities produced in the bulk and in the SHB mixer are similar; (ii) NP morphologies, dimensions, and crystallinities produced in the single-phase SHB and two-phase mixers at the lowest flow rate are similar; and (iii) NP morphologies, dimensions, and crystallinities change with flow rate in the two-phase mixer but not in the single-phase SHB mixer. These findings provide new insights into the relative roles of mixing and shear in the formation and flow-directed processing of polymeric NPs in microfluidics, informing future reactor designs for manufacturing NPs of low polydispersity and controlled multiscale structure and function.

  6. A Comparative Study on Quantitative Assessment of Blood Flow and Vascularization in Polycystic Ovary Syndrome Patients and Normal Women Using Three-Dimensional Power Doppler Ultrasonography.

    Science.gov (United States)

    Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita

    2018-04-01

    To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.

  7. A comparative study of long-term effect of tobacco on resting whole mouth salivary flow rate and pH

    Directory of Open Access Journals (Sweden)

    Sabarni Chakrabarty

    2015-01-01

    Full Text Available Introduction: The taste receptors responsible for salivary secretion are constantly being affected by the harmful by-products of tobacco, and it is believed that tobacco usage on a long-term basis can decrease the sensitivity of taste receptors leading to decreased salivary reflex. It is hypothesized that long-term tobacco usage might lead to altered taste receptors′ response, changing the salivary flow rate (SFR. Unstimulated whole mouth SFR and salivary pH play an important role in the causation of various oral changes and conditions. Aims: The aim of this study is to determine the effects of long-term use of tobacco on SFR and salivary pH and the oral and dental health among tobacco chewers, smokers, and control group. Settings and Design: Cross-sectional study. Materials and Methods: The study comprised a total of 90 patients who were grouped into smokers (group A, smokeless tobacco chewers (group B, and controls (group C. Each group consisted of 30 healthy male adults. Resting whole mouth saliva was collected from every patient; SFR was calculated and then salivary pH was assessed using the salivary pH strips, depending on the color change of the indicator paper strip when compared with a color chart. Statistical Analysis Used: Data were analyzed using the Statistical Package for Social Service (SPSS computer software. Student′s t-test, analysis of variance (ANOVA, and Z-test were applied to assess between-group differences. Results: The mean (±SD SFR was found to be 0.77 (±0.23 ml/min for group A, 0.63 (±0.16 ml/min for group B, and 1.08 (±0.08 ml/min for group C, and on comparing the groups, the result was significant. The mean (±SD pH was found to be 6.8 (±0.20 for group A, 6.65 (±0.30 for group B, and 7.06 (±0.23 for group C and was also found to be significant on comparison. Conclusions: It is concluded from this experimental study on long-term tobacco users that smokeless and smoked forms of tobacco adversely affect

  8. Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings

    International Nuclear Information System (INIS)

    Zhan, Changhong; Duan, Zhiyin; Zhao, Xudong; Smith, Stefan; Jin, Hong; Riffat, Saffa

    2011-01-01

    This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research

  9. COMPARATION OF SEVERAL PLANTS EXTRACT AND VITAMIN C INHIBITION ACTIVITY TO TYROSINE PHOTODEGRADATION INDUCED BY KETOPROFEN AND ITS TOTAL PHENOLIC COMPOUNDS

    Directory of Open Access Journals (Sweden)

    Tatang Irianti

    2016-12-01

    Full Text Available Antioxidant is known to inhibit free radical reaction. Tyrosine photodegradation can be caused by radical reaction. Nowadays, plant with antioxidants are widely used to inhibit free radical reaction. Study of inhibition of photodegradation used four groups. Those groups are: P1 consisted of 2mL tyrosine 0,05 %; P2 consisted of 2 mL tyrosine 0,05 %, and 600 μL Rhetoflam (topical ketoprofen 1 %; P3 consisted of 2 mL tyrosine 0,05 %, 60μL Rhetoflam 1 %, and 100 μL tea leaf water ekstract 0,15 %; P4 consisted of 2 mL tyrosine 0,05 %, 600 μL Rhetoflam 1 %, and 100 μL mahkota dewa fruit water ekstract 0,15 %; P5 consisted of 2 mL tyrosine 0,05 %, 600 μL Rhetoflam 1 %, and 100 μL finger root etanolic ekstract 0,15 %; P6 consisted of 2 mL tyrosine 0,05 %, 600 μL Rhetoflam 1 %, and 100 μL vitamin C 0,15 %; each group is added with aquadest up to 5,0 mL and illuminated with mercuric lamp for four hours. Level of remaining tyrosine was measured with visible spectrophotometric method. We used ANOVA to analyse the data with convidence level of 0,95 and then continued by Tukey (HSD. Follin-Ciocalteu method with galic acid calibration curve was used to determine total phenolic level. The level of total phenolic of tea leaf aquoeus extract, mahkota dewa fruit aquoeus extract, fingerroot ethanolic extract were 29.64±0.86 %; 8.29 % 0.27 %; and 7.11 %, 0.15 %, respectively. Our investigation also found gallic acid equivalent (GAE with the inhibition activity of 4.03; 1.58; and 2.09 and they were bigger than Vitamin C with the same concentration of 0.15 %.

  10. A comparative evaluation of Eosin-5'-maleimide flow cytometry reveals a high diagnostic efficacy for hereditary spherocytosis.

    Science.gov (United States)

    Joshi, P; Aggarwal, A; Jamwal, M; Sachdeva, M U S; Bansal, D; Malhotra, P; Sharma, P; Das, R

    2016-10-01

    Laboratory diagnosis of hereditary spherocytosis (HS) relies on increased incubated red cell osmotic fragility test for screening. We evaluated the diagnostic role of eosin-5'-maleimide (EMA) binding test by flow cytometry in spherocytic and microcytic hypochromic hematological disorders in North Indians. EMA binding test using flow cytometry was performed on 55 HS (40 families), 26 iron deficiency anemia (IDA), 32 β-thalassemia trait (βTT), and 10 autoimmune hemolytic anemia (AIHA) cases and 121 normals. Mean channel fluorescence (MCF) and coefficient of variation (CV) were studied. Different MCF parameters (MCF, MCF ratio, percent decrease MCF) and percent increase in CV were analyzed. Receiver operating characteristics analysis was performed to determine best cutoff values, sensitivity, and specificity for discriminating HS from other red cell disorders. MCF ratio of HS group was significantly lower than normals (0.67 ± 0.07 vs. 1.01 ± 0.05, P < 0.001) and other cases. All patients with HS showed MCF ratio to be ≤0.79. Four postsplenectomy cases with near-normal hemograms also revealed low MCF ratio, showing the specificity of the test. EMA assay was efficient to diagnose cases of HS including postsplenectomy cases and shows no overlap with IDA, βTT, and AIHA. © 2016 John Wiley & Sons Ltd.

  11. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    International Nuclear Information System (INIS)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M.; Sivberg, B.

    2004-01-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, κ w , analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied κ w 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied κ w of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  12. Are digital images good enough? A comparative study of conventional film-screen vs digital radiographs on printed images of total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Eklund, K.; Jonsson, K.; Lindblom, G.; Lundin, B.; Sanfridsson, J.; Sloth, M. [Department of Radiology, Center for Medical Imaging and Physiology, Lund University Hospital, 22185, Lund (Sweden); Sivberg, B. [Department of Nursing, Faculty of Medicine, Lund University, P.O. Box 157, 22100, Lund (Sweden)

    2004-05-01

    The aim of this study was to evaluate the inter- and intra-observer variability and to find differences in diagnostic safety between digital and analog technique in diagnostic zones around hip prostheses. In 80 patients who had had a total hip replacement (THR) for more than 2 years, a conventional image and a digital image were taken. Gruen's model of seven distinct regions of interest was used for evaluations. Five experienced radiologists observed the seven regions and noted in a protocol the following distances: stem-cement; cement-bone; and stem-bone. All images were printed on hard copies and were read twice. Weighted kappa, {kappa}{sub w}, analyses were used. The two most frequently loosening regions, stem-cement region 1 and cement-bone region 7, were closely analyzed. In region 1 the five observers had an agreement of 86.75-97.92% between analog and digital images in stem-cement, which is a varied {kappa}{sub w} 0.29-0.71. For cement-bone region 7 an agreement of 87.21-90.45% was found, which is a varied {kappa}{sub w} of 0.48-0.58. All the kappa values differ significantly from nil. The result shows that digital technique is as good as analog radiographs for diagnosing possible loosening of hip prostheses. (orig.)

  13. A flow injection analyser conductometric coupled system for the field analysis of free dissolved CO{sub 2} and total dissolved inorganic carbon in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Martinotti, Valter; Balordi, Marcella; Ciceri, Giovanni [RSE SpA - Environment and Sustainable Development Department, Milan (Italy)

    2012-05-15

    A flow injection analyser coupled with a gas diffusion membrane and a conductometric microdetector was adapted for the field analysis of natural concentrations of free dissolved CO{sub 2} and dissolved inorganic carbon in natural waters and used in a number of field campaigns for marine water monitoring. The dissolved gaseous CO{sub 2} presents naturally, or that generated by acidification of the sample, is separated by diffusion using a hydrophobic semipermeable gas porous membrane, and the permeating gas is incorporated into a stream of deionised water and measured by means of an electrical conductometric microdetector. In order to make the system suitable and easy to use for in-field measurements aboard oceanographic ships, the single components of the analyser were compacted into a robust and easy to use system. The calibration of the system is carried out by using standard solutions of potassium bicarbonate at two concentration ranges. Calibration and sample measurements are carried out inside a temperature-constant chamber at 25 C and in an inert atmosphere (N{sub 2}). The detection and quantification limits of the method, evaluated as 3 and 10 times the standard deviation of a series of measurements of the matrix solution were 2.9 and 9.6 {mu}mol/kg of CO{sub 2}, respectively. Data quality for dissolved inorganic carbon was checked with replicate measurements of a certified reference material (A. Dickson, Scripps Institution of Oceanography, University of California, San Diego), both accuracy and repeatability were -3.3% and 10%, respectively. Optimization, performance qualification of the system and its application in various natural water samples are reported and discussed. In the future, the calibration step will be operated automatically in order to improve the analytical performance and the applicability will be increased in the course of experimental surveys carried out both in marine and freshwater ecosystems. Considering the present stage of

  14. Combination Intravenous and Intra-Articular Tranexamic acid compared with Intravenous Only Administration and No Therapy in Total Knee Arthroplasty: A Case Series Study

    Directory of Open Access Journals (Sweden)

    Chris Buntting

    2016-07-01

    This study supports the existing literature and suggests that the use of IV Tranexamic acid alone or in combination with intra-articular dose in TKA may reduce the requirement for transfusion (Level IV evidence. Furthermore, this study suggests that the use of tranexamic acid as a combination of Intravenous and intra-articular administration has no effect on range of motion, or medical complications during hospital stay. Although it was not a statistically significant finding, our study suggested a trend towards a greater reduction in haemoglobin and haematocrit fall in the combination therapy group when compared to IV Tranexamic acid alone

  15. Early rehabilitation after total knee replacement surgery: a multicenter, noninferiority, randomized clinical trial comparing a home exercise program with usual outpatient care.

    Science.gov (United States)

    Han, Annie S Y; Nairn, Lillias; Harmer, Alison R; Crosbie, Jack; March, Lyn; Parker, David; Crawford, Ross; Fransen, Marlene

    2015-02-01

    To determine, at 6 weeks postsurgery, if a monitored home exercise program (HEP) is not inferior to usual care rehabilitation for patients undergoing primary unilateral total knee replacement (TKR) surgery for osteoarthritis. We conducted a multicenter, randomized clinical trial. Patients ages 45-75 years were allocated at the time of hospital discharge to usual care rehabilitation (n = 196) or the HEP (n = 194). Outcomes assessed 6 weeks after surgery included the Western Ontario and McMaster Universities Osteoarthritis Index pain and physical function subscales, knee range of motion, and the 50-foot walk time. The upper bound of the 95% confidence interval (95% CI) mean difference favoring usual care was used to determine noninferiority. At 6 weeks after surgery there were no significant differences between usual care and HEP, respectively, for pain (7.4 and 7.2; 95% CI mean difference [MD] -0.7, 0.9), physical function (22.5 and 22.4; 95% CI MD -2.5, 2.6), knee flexion (96° and 97°; 95% CI MD -4°, 2°), knee extension (-7° and -6°; 95% CI MD -2°, 1°), or the 50-foot walk time (12.9 and 12.9 seconds; 95% CI MD -0.8, 0.7 seconds). At 6 weeks, 18 patients (9%) allocated to usual care and 11 (6%) to the HEP did not achieve 80° knee flexion. There was no difference between the treatment allocations in the number of hospital readmissions. The HEP was not inferior to usual care as an early rehabilitation protocol after primary TKR. Copyright © 2015 by the American College of Rheumatology.

  16. Biofuel feedstock and blended coproducts compared with deoiled corn distillers grains in feedlot diets: Effects on cattle growth performance, apparent total tract nutrient digestibility, and carcass characteristics.

    Science.gov (United States)

    Opheim, T L; Campanili, P R B; Lemos, B J M; Ovinge, L A; Baggerman, J O; McCuistion, K C; Galyean, M L; Sarturi, J O; Trojan, S J

    2016-01-01

    Crossbred steers (British × Continental; = 192; initial BW 391 ± 28 kg) were used to evaluate the effects of feeding ethanol coproducts on feedlot cattle growth performance, apparent nutrient digestibility, and carcass characteristics. Steers were blocked by initial BW and assigned randomly to 1 of 6 dietary treatments within block. Treatments (replicated in 8 pens with 4 steers/pen) included 1) control, steam-flaked corn-based diet (CTL), 2) corn dried distillers grains with solubles (DGS; DRY-C), 3) deoiled corn dried DGS (DRY-CLF), 4) blended 50/50 corn/sorghum dried DGS (DRY-C/S), 5) sorghum dried DGS (DRY-S), and 6) sorghum wet DGS (WET-S). Inclusion of DGS was 25% (DM basis). The DGS diets were isonitrogenous, CTL was formulated for 13.5% CP, and all diets were balanced for ether extract. Final shrunk BW, ADG, and DMI did not differ among CTL and DGS treatments ( ≥ 0.19). Overall G:F did not differ from CTL for DRY-C, DRY-CLF, or WET-S ( ≥ 0.12); however, G:F was 9.6% less for DRY-S compared with CTL ( carcass-adjusted G:F vs. DRY-S. For WET-S, final BW and ADG were greater ( Carcass weight, dressing percent, and marbling score did not differ between CTL and DGS diets ( ≥ 0.23). For DRY-S, HCW was lower than for DRY-C ( = 0.02); however, compared with DRY-S, HCW tended to be greater for DRY-C/S ( = 0.10) and WET-S ( = 0.07). At a moderately high (25% DM) inclusion, blending C/S or feeding WET-S resulted in cattle growth performance and carcass characteristics similar to those of CTL and corn-based coproducts.

  17. Comparative study of the energy potential of cyanide waters using two osmotic membrane modules under dead-end flow

    Science.gov (United States)

    García-Díaz, Y.; Quiñones-Bolaños, E.; Bustos-Blanco, C.; Vives-Pérez, L.; Bustillo-Lecompte, C.; Saba, M.

    2017-12-01

    The energy potential of the osmotic pressure gradient of cyanide waters is evaluated using two membrane modules, horizontal and vertical, operated under dead-end flow. The membrane was characterized using Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS). The membrane is mainly composed of carbon, oxygen, and sulphur. The properties of the membrane were unchanged and had no pore clogging after exposure to the cyanide waters. Potentials of 1.78×10-4 and 6.36×10-5Wm-2 were found for the horizontal and vertical modules, respectively, using the Van’t Hoff equation. Likewise, the permeability coefficient of the membrane was higher in the vertical module. Although the energy potential is low under the studied conditions the vertical configuration has a greater potential due to the action of gravity and the homogenous contact of the fluid with the membrane.

  18. Unsteady fluid flow in a slightly curved pipe: A comparative study of a matched asymptotic expansions solution with a single analytical solution

    International Nuclear Information System (INIS)

    Messaris, Gerasimos A. T.; Hadjinicolaou, Maria; Karahalios, George T.

    2016-01-01

    The present work is motivated by the fact that blood flow in the aorta and the main arteries is governed by large finite values of the Womersley number α and for such values of α there is not any analytical solution in the literature. The existing numerical solutions, although accurate, give limited information about the factors that affect the flow, whereas an analytical approach has an advantage in that it can provide physical insight to the flow mechanism. Having this in mind, we seek analytical solution to the equations of the fluid flow driven by a sinusoidal pressure gradient in a slightly curved pipe of circular cross section when the Womersley number varies from small finite to infinite values. Initially the equations of motion are expanded in terms of the curvature ratio δ and the resulting linearized equations are solved analytically in two ways. In the first, we match the solution for the main core to that for the Stokes boundary layer. This solution is valid for very large values of α. In the second, we derive a straightforward single solution valid to the entire flow region and for 8 ≤ α < ∞, a range which includes the values of α that refer to the physiological flows. Each solution contains expressions for the axial velocity, the stream function, and the wall stresses and is compared to the analogous forms presented in other studies. The two solutions give identical results to each other regarding the axial flow but differ in the secondary flow and the circumferential wall stress, due to the approximations employed in the matched asymptotic expansion process. The results on the stream function from the second solution are in agreement with analogous results from other numerical solutions. The second solution predicts that the atherosclerotic plaques may develop in any location around the cross section of the aortic wall unlike to the prescribed locations predicted by the first solution. In addition, it gives circumferential wall stresses

  19. Unsteady fluid flow in a slightly curved pipe: A comparative study of a matched asymptotic expansions solution with a single analytical solution

    Energy Technology Data Exchange (ETDEWEB)

    Messaris, Gerasimos A. T., E-mail: messaris@upatras.gr [Department of Physics, Division of Theoretical Physics, University of Patras, GR 265 04 Rion (Greece); School of Science and Technology, Hellenic Open University, 11 Sahtouri Street, GR 262 22 Patras (Greece); Hadjinicolaou, Maria [School of Science and Technology, Hellenic Open University, 11 Sahtouri Street, GR 262 22 Patras (Greece); Karahalios, George T. [Department of Physics, Division of Theoretical Physics, University of Patras, GR 265 04 Rion (Greece)

    2016-08-15

    The present work is motivated by the fact that blood flow in the aorta and the main arteries is governed by large finite values of the Womersley number α and for such values of α there is not any analytical solution in the literature. The existing numerical solutions, although accurate, give limited information about the factors that affect the flow, whereas an analytical approach has an advantage in that it can provide physical insight to the flow mechanism. Having this in mind, we seek analytical solution to the equations of the fluid flow driven by a sinusoidal pressure gradient in a slightly curved pipe of circular cross section when the Womersley number varies from small finite to infinite values. Initially the equations of motion are expanded in terms of the curvature ratio δ and the resulting linearized equations are solved analytically in two ways. In the first, we match the solution for the main core to that for the Stokes boundary layer. This solution is valid for very large values of α. In the second, we derive a straightforward single solution valid to the entire flow region and for 8 ≤ α < ∞, a range which includes the values of α that refer to the physiological flows. Each solution contains expressions for the axial velocity, the stream function, and the wall stresses and is compared to the analogous forms presented in other studies. The two solutions give identical results to each other regarding the axial flow but differ in the secondary flow and the circumferential wall stress, due to the approximations employed in the matched asymptotic expansion process. The results on the stream function from the second solution are in agreement with analogous results from other numerical solutions. The second solution predicts that the atherosclerotic plaques may develop in any location around the cross section of the aortic wall unlike to the prescribed locations predicted by the first solution. In addition, it gives circumferential wall stresses

  20. Unsteady fluid flow in a slightly curved pipe: A comparative study of a matched asymptotic expansions solution with a single analytical solution

    Science.gov (United States)

    Messaris, Gerasimos A. T.; Hadjinicolaou, Maria; Karahalios, George T.

    2016-08-01

    The present work is motivated by the fact that blood flow in the aorta and the main arteries is governed by large finite values of the Womersley number α and for such values of α there is not any analytical solution in the literature. The existing numerical solutions, although accurate, give limited information about the factors that affect the flow, whereas an analytical approach has an advantage in that it can provide physical insight to the flow mechanism. Having this in mind, we seek analytical solution to the equations of the fluid flow driven by a sinusoidal pressure gradient in a slightly curved pipe of circular cross section when the Womersley number varies from small finite to infinite values. Initially the equations of motion are expanded in terms of the curvature ratio δ and the resulting linearized equations are solved analytically in two ways. In the first, we match the solution for the main core to that for the Stokes boundary layer. This solution is valid for very large values of α. In the second, we derive a straightforward single solution valid to the entire flow region and for 8 ≤ α flows. Each solution contains expressions for the axial velocity, the stream function, and the wall stresses and is compared to the analogous forms presented in other studies. The two solutions give identical results to each other regarding the axial flow but differ in the secondary flow and the circumferential wall stress, due to the approximations employed in the matched asymptotic expansion process. The results on the stream function from the second solution are in agreement with analogous results from other numerical solutions. The second solution predicts that the atherosclerotic plaques may develop in any location around the cross section of the aortic wall unlike to the prescribed locations predicted by the first solution. In addition, it gives circumferential wall stresses augmented by approximately 100% with respect to the matched asymptotic expansions

  1. Magnetohydrodynamic and thermal radiation effects on the boundary-layer flow due to a moving extensible surface with the velocity slip model: A comparative study of four nanofluids

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Emad H., E-mail: efarag@uj.edu.sa [Department of Mathematics, Faculty of Science, University of Jeddah, Jeddah 21589 (Saudi Arabia); Department of Mathematics, Faculty of Education, Ain Shams University, Roxy, Cairo 11757 (Egypt); Sayed, Hamed M. [Department of Mathematics, Faculty of Education, Ain Shams University, Roxy, Cairo 11757 (Egypt); Department of Mathematics, Faculty of Sciences, Taibah University, Yanbu (Saudi Arabia)

    2017-01-15

    In the current work, we investigated effects of the velocity slip for the flow and heat transfer of four nanofluids over a non-linear stretching sheet taking into account the thermal radiation and magnetic field in presence of the effective electrical conductivity. The governing partial differential equations were transformed into a set of nonlinear ordinary differential equation using similarity transformations before being solved numerically by the Chebyshev pseudospectral differentiation matrix (ChPDM). It was found that the investigated parameters affect remarkably on the nanofluid stream function for the whole investigated nanoparticles. In addition, velocity and skin friction profiles of the four investigated nanofluids decreases and increases, respectively, with the increase of the magnetic parameter, first-order and second-order velocity slips. Further, the flow velocity, surface shear stress and temperature are strongly influenced on applying the velocity slip model, where lower values of the second-order imply higher surface heat flux and thereby making the fluid warmer. - Highlights: • A comparative study for four nanoparticles with MHD and thermal radiation effects was studied. • The effective electrical conductivity is mandatory; otherwise a spurious physical sight will be gained. • The investigated parameters affect remarkably on the nanofluids' flow. • The flow velocity, surface shear stress and temperature are strongly influenced by the slip model. • Lower values of the second-order imply higher surface heat flux and thereby making the fluid warmer.

  2. Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system.

    Science.gov (United States)

    Saleh, Mahdi; Spence, John Nathan; Nayak, Sanjeev; Pearce, Gillian; Tennuci, Christopher; Roffe, Christine

    2012-01-01

    There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. Thrombi made of lamb's blood were placed into a pulsatile flow system perfused with Hartmann's solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted.

  3. iagnostic accuracy study comparing total alkaline phosphatase with intact parathyroid hormone 1-84 for the diagnosis of high turnover renal osteodystrophy in chronic renal failure on hemodialysis

    Directory of Open Access Journals (Sweden)

    Andrés Marcelo Rojas González

    2014-09-01

    Full Text Available INTRODUCTION High turnover renal osteodystrophy (HTRO is a highly prevalent complication in patients with chronic kidney disease and mineral bone disease (CKD-MBD, causing pain and significant fracture-associated morbidity and mortality. The diagnostic gold standard test is bone biopsy but there are other, more widely available screening tests such as 1-84 intact parathormone (1-84 iPTH and nonspecific markers such as total alkaline phosphatase (tALP. PURPOSE To determine the diagnostic value (ROC curve, predictive values and likelihood ratios of 1-84 iPTH and tALP for HTRO screening. METHODS A diagnostic accuracy study was performed on a sample of CKD-MDB patients, grouping them according to bone biopsy results and analyzing the results of the diagnostic tests as descriptive variables. RESULTS The study group comprised 188 patients with CKD-MDB, 36 of which had biopsy-confirmed HTRO (19.15%. The average age was 50.2 years in the biopsy group, and 53.4 years in the non-biopsy group (p=0.2385, most were male (63.8% and diabetic (80.5%. The mean time in dialysis was 5.02 years in the biopsy group, and 2.61 years for the non-biopsy group (p<0.001. The mean Kt/V was 1.44 in the biopsy group, and 1.40 in the non-biopsy group (p=0.5354. The mean tALP was 398.02 IU/L in the group with HTRO versus 141.76 IU/L in the group without HTRO (p<0.001. The best cut-off value for tALP was 300-350 IU/L with a near 80% post-test probability, but also with a 15-20% probability for HTRO if the test is negative. The mean 1-84 iPTH was 1248.01 pg/ml in the group with HTRO versus 350.76 pg/ml in the group without HTRO (p<0.001. The 1-84 iPTH cut-off reference value of 300 pg/ml was associated with a post-test probability of 30% for HTRO diagnosis and had a lower overall performance. The best cut-off value for iPTH 1-84 was 600 pg/ml with a post-test probability for HTRO of 70% if positive and less than 5% if the test results are negative. DISCUSSION Both markers show

  4. The impact of coronary chronic total occlusion percutaneous coronary intervention upon donor vessel fractional flow reserve and instantaneous wave-free ratio: Implications for physiology-guided PCI in patients with CTO.

    Science.gov (United States)

    Mohdnazri, Shah R; Karamasis, Grigoris V; Al-Janabi, Firas; Cook, Christopher M; Hampton-Till, James; Zhang, Jufen; Al-Lamee, Rasha; Dungu, Jason N; Gedela, Swamy; Tang, Kare H; Kelly, Paul A; Davies, Justin E; Davies, John R; Keeble, Thomas R

    2018-03-22

    To investigate the immediate and short term impact of right coronary artery (RCA) chronic total coronary occlusion (CTO) percutaneous coronary intervention (PCI) upon collateral donor vessel fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). CTO PCI influences collateral donor vessel physiology, making the indication and/or timing of donor vessel revascularization difficult to determine. In patients with RCA CTO, FFR, iFR, and collateral function index (FFR coll ) were measured in LAD and LCx pre-CTO PCI, immediately post and at 4 month follow-up. 34 patients underwent successful PCI. In the predominant donor vessel immediately post PCI, FFR, and FFR coll did not change (0.76 ± 0.12 to 0.75 ± 0.13, P = 0.267 and 0.31 ± 0.10 vs. 0.34 ± 0.11, P = 0.078), but iFR increased significantly (0.86 ± 0.10 to 0.88 ± 0.10, P = 0.012). At follow-up, there was a significant increase in predominant donor FFR and iFR (0.76 ± 0.12 to 0.79 ± 0.11, P = 0.047 and 0.86 ± 0.10 to 0.90 ± 0.07, P = 0.003), accompanied by a significant reduction in FFR coll (0.31 ± 0.10 to 0.18 ± 0.07 P PCI in the case of iFR and at 4-month follow-up for FFR and iFR compared to pre-PCI with a concomitant reduction in collateral function. © 2018 Wiley Periodicals, Inc.

  5. Effective flow performances and dialysis doses delivered with permanent catheters: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses.

    Science.gov (United States)

    Canaud, Bernard; Leray-Moragues, Hélène; Kerkeni, Nadia; Bosc, Jean-Yves; Martin, Katja

    2002-07-01

    Permanent venous catheters have emerged as a long-term vascular access option for renal replacement therapy in end-stage renal disease patients. The design and venous location of catheter devices bear intrinsic flow limitations that may negatively affect the adequacy of dialysis and the patient outcome. There is limited data comparing the long-term dialysis adequacy delivered with permanent catheters vs arterio-venous vascular accesses (AVA). To explore this problem, we conducted a prospective 24-month trial comparing the flow performances and dialysis dose (Kt/Vdp) deliveries of both access options in a group of 42 haemodialysis patients during two study phases. During the first 12 months the patients completed a treatment period by means of permanent dual silicone catheters (DualKT). Then they were transferred to an AVA (40 native arterio-venous fistulas and two PTFE grafts) and monitored for an additional 12-month period. Assessments of flow adequacy and dialysis quantification were performed monthly. Dialysis adequacy was achieved in all cases. No patient had to be transferred prematurely to the AVA because of catheter failure. Three catheters had to be replaced due to bacteraemia in three patients. The mean effective blood flow rates achieved were 316+/-3.5 ml/min and 340+/-3.3 ml/min with DualKT and AVA, respectively, for a pre-set machine blood flow of 348+/-2.2 ml/min. Recirculation rates evaluated with the 'slow blood flow' method were 8.6+/-0.6 and 12.1+/-0.8% for DualKT and AVA using mean values of the solute markers urea and creatinine. Due to the possibility of a comparison veno-venous vs arterio-venous blood circulation, a corrected arterio-venous access recirculation could be derived from the difference between the two, which was around 3%. The blood flow resistance of the DualKT was slightly higher than with AVA as indicated by venous pressure differences. Kt/Vdp delivered was 1.37+/-0.02 and 1.45+/-0.02 with DualKT and AVA access respectively. The

  6. Total Logistic Plant Solutions

    Directory of Open Access Journals (Sweden)

    Dusan Dorcak

    2016-02-01

    Full Text Available The Total Logistics Plant Solutions, plant logistics system - TLPS, based on the philosophy of advanced control processes enables complex coordination of business processes and flows and the management and scheduling of production in the appropriate production plans and planning periods. Main attributes of TLPS is to create a comprehensive, multi-level, enterprise logistics information system, with a certain degree of intelligence, which accepts the latest science and research results in the field of production technology and logistics. Logistic model of company understands as a system of mutually transforming flows of materials, energy, information, finance, which is realized by chain activities and operations

  7. DETERMINACIONES DE FLUJO DEL SUERO COSTEÑO CON DIFERENTES CONCENTRACIONES DE SÓLIDOS TOTALES DETERMINAÇÃO DE FLUJO DO SORO COSTENHO CON DIFERENTES CONCENTRAÇOES DO SOLIDOS TOTAIS SUERO COSTEÑO FLOW DETERMINATIONS WITH DIFFERENT CONCENTRATIONS OF TOTAL SOLIDS

    Directory of Open Access Journals (Sweden)

    DIOFANOR ACEVEDO

    2012-12-01

    Full Text Available El objetivo de este estudio fue determinar los efectos del incremento de los sólidos totales con lactosuero parcialmente desmineralizado en las determinaciones de flujo del Suero costeño. Los resultados muestran que el flujo fue de naturaleza no-newtoniana, las curvas se ajustaron mejor al modelo de Herschel-Bulkley, previamente evaluado por la ecuación de Casson. El aumento de los sólidos totales disminuye el índice de flujo (n, aumenta el umbral de fluencia (?0 y el coeficiente de consistencia (K, presentando un adelgazamiento por corte o cizalladuraO objetivo deste estudo foi determinar os efeitos do aumento de sólidos totais com soro parcialmente desmineralizado na determinação do fluxo de soro costenho. Os resultados mostram que o fluxo era de curvas não-newtoniano montado um modelo de Herschel-Bulkley, previamente avaliada pela equação de Casson. O aumento do teor de sólidos diminui a taxa de fluxo (n aumenta a tensão de escoamento (?0 e o coeficiente de consistência (K, indicando uma tesoura de desbaste ou de corte.The main objective in this study was to determine the effects of increment in total solids concentration with partially dematerialized whey for the flow determinations in Suero Costeño. The results shown that the increase in total solids concentration affects the rheological properties, like consistency coefficient (K and an increment of the values of yield stress (?0, while the flow index (n values slightly decreased, showing a leverage in shear-thinning behavior

  8. Determination of inorganic mercury and total mercury in biological and environmental samples by flow injection-cold vapor-atomic absorption spectrometry using sodium borohydride as the sole reducing agent

    International Nuclear Information System (INIS)

    Rio Segade, Susana; Tyson, Julian F.

    2003-01-01

    A simple, fast, precise and accurate method to determine inorganic mercury and total mercury in biological and environmental samples was developed. The optimized flow-injection mercury system permitted the separate determination of inorganic mercury and total mercury using sodium borohydride as reducing agent. Inorganic mercury was selectively determined after reduction with 10 -4 % w/v sodium borohydride, while total mercury was determined after reduction with 0.75% w/v sodium borohydride. The calibration graphs were linear up to 30 ng ml -1 . The detection limits of the method based on three times the standard deviation of the blank were 24 and 3.9 ng l -1 for total mercury and inorganic mercury determination, respectively. The relative standard deviation was less than 1.5% for a 10 ng ml -1 mercury standard. As a means of checking method performance, deionized water and pond water samples were spiked with methylmercury and inorganic mercury; quantitative recovery for total mercury and inorganic mercury was obtained. The accuracy of the method was verified by analyzing alkaline and acid extracts of five biological and sediment reference materials. Microwave-assisted extraction procedures resulted in higher concentrations of recovered mercury species, lower matrix interference with mercury determination and less time involved in sample treatment than conventional extraction procedures. The standard addition method was only needed for calibration when biological samples were analyzed. The detection limits were in the range of 1.2-19 and 6.6-18 ng g -1 in biological and sediment samples for inorganic mercury and total mercury determination, respectively

  9. Myocardial thallium-201 kinetics and regional flow alterations with 3 hours of coronary occlusion and either rapid reperfusion through a totally patent vessel or slow reperfusion through a critical stenosis

    International Nuclear Information System (INIS)

    Granato, J.E.; Watson, D.D.; Flanagan, T.L.; Beller, G.A.

    1987-01-01

    Myocardial thallium-201 kinetics and regional blood flow alterations were examined in a canine model using 3 hours of coronary occlusion and different methods of reperfusion. Group I comprised 10 dogs undergoing a 3 hour left anterior descending artery occlusion and no reperfusion. Group II comprised seven dogs undergoing 3 hours of left anterior descending artery occlusion and rapid reperfusion through a totally patent vessel. Group III comprised 10 dogs undergoing 3 hours of left anterior descending artery occlusion and slow reperfusion through a residual stenosis. All dogs received 1.5 mCi of thallium-201 after 40 minutes of coronary occlusion. During occlusion and 2 hours of reperfusion, serial hemodynamic, blood flow and myocardial thallium-201 activity measurements were made. The relative thallium-201 gradient (normal zone minus ischemic zone activity when initial normal activity is expressed as 100%) during left anterior descending coronary occlusion was similar in all groups. Group I, 87 +/- 3%; Group II, 78 +/- 6%; Group III, 83 +/- 6% (p = NS). After 2 hours of either method of reperfusion, the final relative gradient had decreased to a similar level (Group II, 51 +/- 9%; Group III, 42 +/- 6%). These values were not significantly different from the final relative thallium-201 gradient seen in dogs undergoing a sustained 3 hour occlusion (Group I, 55 +/- 5%). After 2 hours of reperfusion, both methods of reflow were associated with similar degrees of ''no reflow.'' Transmural flows in the central ischemic zone were 89 +/- 10% of normal in Group II and 71 +/- 6% of normal in Group III after reperfusion, with both flows substantially higher than the relative thallium-201 activities in these dogs

  10. Comparing depth-dependent curing radiant exposure and time of curing of regular and flow bulk-fill composites.

    Science.gov (United States)

    Rodrigues, Jose Augusto; Tenorio, Ilana Pais; Mello, Ginger Baranhuk Rabello de; Reis, André Figueiredo; Shen, Chiayi; Roulet, Jean-François

    2017-08-21

    The effect of restoration depth on the curing time of a conventional and two bulk-fill composite resins by measuring microhardness and the respective radiosity of the bottom surface of the specimen was investigated. 1-, 3- and 5-mm thick washers were filled with Surefil SDR Flow-U (SDR), Tetric EvoCeram Bulk Fill-IVA (TEC) or Esthet-X HD-B1 (EHD), and cured with Bluephase® G2 for 40s. Additional 1-mm washers were filled with SDR, TEC or EHD, placed above the light sensor of MARC®, stacked with pre-cured 1-, 3- or 5-mm washer of respective material, and cured for 2.5~60s to mimic 2-, 4- and 6-mm thick composite curing. The sensor measured the radiosity (EB) at the bottom of specimen stacks. Vickers hardness (VH) was measured immediately at 5 locations with triplicate specimens. Nonlinear regression of VH vs EB by VH=α[1-exp(-EB/β)] with all thickness shows that the values of α, maximum hardness, are 21.6±1.0 kg/mm2 for SDR, 38.3±0.6 kg/mm2 for TEC and 45.3±2.6 kg/mm2 for EHD, and the values of β, rate parameter, are 0.40±0.06 J/cm2 for SDR, 0.77±0.04 J/cm2 for TEC and 0.58±0.09 J/cm2 for EHD. The radiosity of the bottom surface was calculated when the bottom surface of each material attained 80% of α of each material. The curing times for each material are in agreement with manufacturer recommendation for thickness. It is possible to estimate time needed to cure composite resin of known depth adequately by the radiosity and microhardness of the bottom surface.

  11. A Pilot Study Comparing Total Physical Response Storytelling[TM] with the Grammar-Translation Teaching Strategy to Determine Their Effectiveness in Vocabulary Acquisition among English as a Second Language Adult Learners

    Science.gov (United States)

    Castro, Ruben

    2010-01-01

    This study evaluated the effectiveness of Total Physical Response Storytelling (TPRS[TM]) compared to the Grammar-Translation approach for acquiring and retaining new vocabulary in an English as a Second Language (ESL) class. The subjects were adult Hispanic learners with limited literacy. An experimental design approach was used to gather…

  12. Comparative Study for Evaluation of Mass Flow Rate for Simple Solar Still and Active with Heat Pump

    OpenAIRE

    Hidouri Khaoula; Benhmidene Ali; Chaouachi Bechir; Ravishankar Sathyamurthy

    2017-01-01

    In isolated and arid areas, especially in the almost Maghreb regions, the abundant solar radiation intensity along the year and the available brackish water resources are the two favorable conditions for using solar desalination technology to produce fresh water. The present study is based on the use of three groups of correlation, for evaluating mass transfer. Theoretical results are compared with those obtained experimentally for a Simple Solar Distiller (SSD) and a Simple Solar Distiller H...

  13. Comparative Study for Evaluation of Mass Flow Rate for Simple Solar Still and Active with Heat Pump

    Directory of Open Access Journals (Sweden)

    Hidouri Khaoula

    2017-07-01

    Full Text Available In isolated and arid areas, especially in the almost Maghreb regions, the abundant solar radiation intensity along the year and the available brackish water resources are the two favorable conditions for using solar desalination technology to produce fresh water. The present study is based on the use of three groups of correlation, for evaluating mass transfer. Theoretical results are compared with those obtained experimentally for a Simple Solar Distiller (SSD and a Simple Solar Distiller Hybrid with a Heat Pump (SSDHP stills. Experimental results and those calculated by Lewis number correlation show good agreements. Results obtained by Dunkle, Kumar and Tiwari correlations are not satisfactory with the experimental ones. Theoretical results, as well as statistical analysis, are presented. The model with heat pump ( for two configurations (111 and (001 give more output compared with the model without heat pump ((000 and (110. This results where agree for the use of the statistic results, the error it less with Lewis number as compared with the different correlation.

  14. Site and extent of digestion, duodenal flow, and intestinal disappearance of total and esterified fatty acids in sheep fed a high-concentrate diet supplemented with high-linoleate safflower oil.

    Science.gov (United States)

    Atkinson, R L; Scholljegerdes, E J; Lake, S L; Nayigihugu, V; Hess, B W; Rule, D C

    2006-02-01

    Our objective was to determine duodenal and ileal flows of total and esterified fatty acids and to determine ruminal fermentation characteristics and site and extent of nutrient digestion in sheep fed an 80% concentrate diet supplemented with high-linoleate (77%) safflower oil at 0, 3, 6, and 9% of DM. Oil was infused intraruminally along with an isonitrogenous basal diet (fed at 2% of BW) that contained bromegrass hay, cracked corn, corn gluten meal, urea, and limestone. Four crossbred wethers (BW = 44.3 +/- 15.7 kg) fitted with ruminal, duodenal, and ileal cannulas were used in a 4 x 4 Latin square experiment, in which 14 d of dietary adaptation were followed by 4 d of duodenal, ileal, and ruminal sampling. Fatty acid intake increased (linear, P = 0.004 to 0.001) with increased dietary safflower oil. Digestibilities of OM, NDF, and N were not affected (P = 0.09 to 0.65) by increased dietary safflower oil. For total fatty acids (free plus esterified) and esterified fatty acids, duodenal flow of most fatty acids, including 18:2c-9,c-12, increased (P = 0.006 to 0.05) with increased dietary oil. Within each treatment, duodenal flow of total and esterified 18:2c-9,c-12 was similar (P = 0.32), indicating that duodenal flow of this fatty acid occurred because most of it remained esterified. Duodenal flow of esterified 18:1t-11 increased (P = 0.08) with increased dietary safflower oil, indicating that reesterification of ruminal fatty acids occurred. Apparent small intestinal disappearance of most fatty acids was not affected (P = 0.19 to 0.98) by increased dietary safflower oil, but increased (P = 0.05) for 18:2c-9,c-12, which ranged from 87.0 to 97.4%, and for 18:2c-9,t-11 (P = 0.03), which ranged from 37.9% with no added oil to 99.2% with supplemental oil. For esterified fatty acids, apparent small intestinal disappearance was from 80% for 18:3c-9,c-12,c-15 at the greatest level of dietary oil up to 100% for 18:1t-11 and 18:1c-12 with 0% oil. We concluded that

  15. Comparative evaluation of ventilatory function through pre and postoperative peak expiratory flow in patients submitted to elective upper abdominal surgery.

    Science.gov (United States)

    Scheeren, Caio Fernando Cavanus; Gonçalves, José Júlio Saraiva

    2016-01-01

    to evaluate the ventilatory function by Peak Expiratory Flow (PEF) in the immediate pre and postoperative periods of patients undergoing elective surgical procedures in the upper abdomen. we conducted a prospective cohort study including 47 patients admitted to the Hospital Regional de Mato Grosso do Sul from July to December 2014, who underwent elective surgeries of the upper abdomen, and submiited to spirometric evaluation and measurement of PEF immediately before and after surgery. of the 47 patients, 22 (46.8%) were male and 25 (53.20%) female. The mean preoperative PEF was 412.1±91.7, and postoperative, 331.0±87.8, indicating significant differences between the two variables. Men had higher PEF values than women, both in the pre and postoperative periods. There was a reasonable inverse correlation between age and decreased PEF. Both situations showed statistical significance (pvalores de PFE do que o feminino, tanto no pré-cirúrgico quanto no pós-cirúrgico. Observou-se razoável correlação inversamente proporcional entre as variáveis idade e diminuição do PFE. Ambas as situações mostraram significância estatística (pvalores de PFE tanto no pré como no pós-operatório. O grupo composto por portadores de co-morbidades (HAS e/ou DM) apresentou menores valores de PFE tanto no pré como no pós-operatório (p=0,005). Em ambos os grupos, o pós-operatório determinou uma diminuição significativa do PFE (p<0,001). O tipo de cirurgia realizada e o tipo de anestesia não mostraram diferenças significantes em relação ao PFE. as variáveis mais implicadas na diminuição da função ventilatória, avaliadas através da PFE, foram: idade avançada, tabagismo e presença de comorbidades.

  16. Characteristics of Cerebral Blood Flow in Vascular Dementia using SPM Analysis Compared to Normal Control and Alzheimer's Dementia

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Park, Kyung Won; Kim, Jae Woo [College of Medicine, Univ. of Donga, Busan (Korea, Republic of)

    2003-07-01

    Cerebral perfusion pattern of vascular dementia (VD) was not well established and overlap of cerebral perfusion pattern was reported between VD and Alzheimer's dementia (AD). The aim of this study is to assess the specific patterns of SPECT finding in VD compared with normal control subjects and to disclose differences of cerebral blood flow between subjects with VD and AD were investigated using statistic parametric mapping analysis. Thirty-two VD (mean age ; 67.86.4 years, mean CDR ; 0.980.27), 51 AD (mean age ; 71.47.2 years, CDR ; 1.160.47), which were matched for age and severity of dementia, and 30 normal control subjects (mean age ; 60.17.7 years) participated in this study. The Tc-99m HMPAO brain perfusion SPECT data were analyzed by SPM99. The SPECT data of the patients with VD were compared to those of the control subjects and then compared to the patients with AD. SPM analysis of the SPECT image showed significant perfusion deficits in the both frontal (both cingulate gyrus, both inferior frontal gyrus, B no.47, right frontal rectal gyrus, left frontal subcallosal gyrus, B no.25), both temporal (right insula, B no.13, left superior temporal gyrus, left parahippocampal gyrus, B no.35), occipital (occipital lingual gyrus), right corpus callosum and right cerebellar tonsil regions in subjects with VD compared with normal control subjects (uncorrected p<0.01). Comparison of the two dementia groups (uncorrected p<0.01) revealed significant hypoperfusion in both parietal posterior central gyrus, right inferior frontal gyrus (B no.47), left insula, right thalamus (ventral lateral nucleus), right claustrum and right occipital cuneus regions in VD group compared with AD. There were no typical confined regional hypoperfusion areas but scattered multiple perfusion deficits in VD compared AD. These findings may be helpful to reflect the pathophysiological mechanisms of VD and to disclose differences of cerebral blood flow between subjects with VD and AD.

  17. Comparative estimation of inevitable endogenous ileal flow of amino acids in Pekin ducks under varying dietary or physiological conditions and their significance to nutritional requirements for amino acids.

    Science.gov (United States)

    Akinde, D O

    2017-10-01

    In 2 experiments in Pekin ducks the inevitable endogenous ileal flow (IEIF) of AA was estimated at changing intake and source of crude fiber (CF) or soybean oil (SO) level. Also the roles of dry matter intake (DMI) and BW or age as well as the proportion of IEIF in the dietary requirement for AA were studied. In experiment 1 three basal CP (20, 60, or 100 g/kg) diets were formulated containing a low CF (LCF, 30 g/kg) or high (HCF, 80 g/kg) level; achieved with cellulose supplementation. All diets were similar in every other respect including having SO content of 40 g/kg. Four floor pens of eight 85-day-old ducks were randomly allocated to each diet. Similar diets were mixed in experiment 2 but corn cob meal replaced cellulose as the fiber source. A high SO (HSO) series was also formed by increasing the SO level from 40 g/kg in the basal series to 100 g/kg. Thus the LCF series was concurrently classified as low SO (LSO) series to control SO effect. Each of the eventual 9 diets were fed to 5 floor pens of ten 65-day-old ducks. Ileal AA flow was measured after a 5 day feeding period in both experiments. Linear regression was calculated between ileal flow and dietary intake of individual AA. The IEIF interpreted as the y-intercept of each linear function responded neither to elevated ingestion of each CF type nor to SO level. Age and DMI had no effect on IEIF computed in relation to BW, but wide discrepancies resulted when related to DMI. Overall IEIF of AA varied between 14.3 to 129.8 mg/kg BW d-1. These flows were established in model computations to account for 10 to 64% of the recommended intake of limiting AA. In conclusion the ileal inevitable flow is constant within the dietary/age conditions investigated. However it is modulated by feed intake and accounts for a significant portion of total amino acid requirement. © 2017 Poultry Science Association Inc.

  18. Regional cerebral blood flow and brain atrophy in senile dementia of Alzheimer type (SDAT). Comparing with multi-infarct dementia (MID), and aged control

    Energy Technology Data Exchange (ETDEWEB)

    Okada, K; Kobayashi, S; Yamaguchi, S; Kitani, M; Tsunematsu, T

    1987-05-01

    To investigate the relationship between the reduction of cerebal blood flow and brain atrophy in SDAT, these were measured in 13 cases of senile dementia of Alzheimer type, and compared to 15 cases of multi-infarct Dementia, 39 cases of lacunar infarction without dementia (non-demented CVD group) and 69 cases of aged normal control. Brain atrophy was evaluated by two-dimensional method on CT film by digitizer and regional cerebral blood flow (rCBF) was measured by /sup 133/Xe inhalation method. The degree of brain atrophy in SDAT was almost similar of that of MID. But it was more severe than that of non-demented group. MID showed the lowest rCBF among these groups. SDAT showed significantly lower rCBF than that of aged control, but rCBF in SDAT was equal to that of lacunar stroke without dementia. Focal reduction of cerebral blood flow in bilateral fronto-parietal and left occipital regions were observed in SDAT. Verbal intelligence score (Hasegawa's score) correlated with rCBF and brain atrophy index in MID, and a tendency of correlation between rCBF and brain atrophy in MID was also observed. However, there was no correlation among those indices in SDAT. These findings suggest that the loss of brain substance dose not correspond to the reduction of rCBF in SDAT and simultaneous measurement of rCBF and brain atrophy was useful to differ SDAT from MID.

  19. A comparative study of scale-adaptive and large-eddy simulations of highly swirling turbulent flow through an abrupt expansion

    International Nuclear Information System (INIS)

    Javadi, Ardalan; Nilsson, Håkan

    2014-01-01

    The strongly swirling turbulent flow through an abrupt expansion is investigated using highly resolved LES and SAS, to shed more light on the stagnation region and the helical vortex breakdown. The vortex breakdown in an abrupt expansion resembles the so-called vortex rope occurring in hydro power draft tubes. It is known that the large-scale helical vortex structures can be captured by regular RANS turbulence models. However, the spurious suppression of the small-scale structures should be avoided using less diffusive methods. The present work compares LES and SAS results with the experimental measurement of Dellenback et al. (1988). The computations are conducted using a general non-orthogonal finite-volume method with a fully collocated storage available in the OpenFOAM-2.1.x CFD code. The dynamics of the flow is studied at two Reynolds numbers, Re=6.0×10 4 and Re=10 5 , at the almost constant high swirl numbers of Sr=1.16 and Sr=1.23, respectively. The time-averaged velocity and pressure fields and the root mean square of the velocity fluctuations, are captured and investigated qualitatively. The flow with the lower Reynolds number gives a much weaker outburst although the frequency of the structures seems to be constant for the plateau swirl number

  20. A comparative study on the solubility and stability of p-phenylenediamine-based organic redox couples for non-aqueous flow batteries

    Science.gov (United States)

    Kim, Hyun-seung; Lee, Keon-Joon; Han, Young-Kyu; Ryu, Ji Heon; Oh, Seung M.

    2017-04-01

    A methyl-substituted p-phenylenediamine (PD), N,N,N‧,N‧-tetramethyl-p-phenylenediamine (TMPD), is examined as a positive redox couple with high energy density for non-aqueous Li-flow batteries. Methyl substitution affects the solubility of the redox couple, as the solubility is increased by a factor of ten, to a maximum solubility of 5.0 M in 1.0 M lithium tetrafluoroborate-propylene carbonate supporting electrolyte due to elimination of the hydrogen bonding between the solute molecules. The methyl substitution also enhances the chemical stability of the cation radical and di-cation being generated from PD, as the redox center is shielded by the methyl groups. Furthermore, this organic redox couple demonstrate two-electron redox reactions at 3.2 and 3.8 V (vs. Li/Li+); therefore, the volumetric capacity is twice higher compared to conventional one-electron involved redox couples. In a non-flowing Li/TMPD coin-cell, this organic redox couple demonstrates very stable cycleability as a positive redox couple for non-aqueous flow batteries.

  1. Flow in data racks

    Directory of Open Access Journals (Sweden)

    Manoch Lukáš

    2014-03-01

    Full Text Available This paper deals with the flow in data racks. The aim of this work is to find a new arrangement of elements regulating the flow in the data rack so that the aerodynamic losses and the recirculation zones were minimized. The main reason for solving this problem is to reduce the costs of data racks cooling. Another problem to be solved is a reverse flow in the servers, thus not cooled, occuring due to the underpressure in the recirculation zones. In order to solve the problem, the experimental and numerical model of 27U data rack fitted with 10 pieces of server models with a total input of 10 kW was created. Different configurations of layout of elements affecting the flow in the inlet area of the data rack were compared. Depending on the results achieved, design solutions for the improvement of existing solutions were adopted and verified by numerical simulations.

  2. The impact of intrahepatic microcapsule transplantation on the liver function and liver blood flow: a comparative study of different transplantation approaches

    International Nuclear Information System (INIS)

    Ai Zhaodong; Wang Wei; Gao Feng; Rong Pengfei; Zheng Wei; Dong Qiong; Liu Sheng

    2011-01-01

    Objective: to compare the impact of intrahepatic microcapsule transplantation on the liver function and liver blood flow between via portal vein approach and via hepatic artery approach. Methods: Twenty healthy male dogs were randomly and equally divided into four groups: A1, A2, V1 and V2. For group V1 and group V2, the microcapsules were implanted into portal vein through percultaneous transhepatic approach under ultrasonographic guidance, while for group A1 and group A2, the microcapsules were implanted into hepatic artery through hepatic artery catheterization. The quantity of microcapsules implanted into group A1 and group A2 was 32000 microcapsule/Kg and 48000 microcapsule/Kg respectively, while for group V1 and group V2 was 16000 microcapsule/Kg and 32000 microcapsule/Kg respectively. Before, during and after the microcapsule transplantation ultrasonography was performed to determine the hepatic blood flow rate as well as the diameter of the portal vein. ALT, AST and the main serum liver fibrosis indexes were measured before and after the transplantation. Samples of the livers were pathologically examined before and after the operation. The results were compared between each group. Results: No significant changes in blood flow rate of main portal vein was found after the transplantation in both group A1 and group A2. In both group V1 and group V2 the blood flow of main portal vein became slow during the procedure but recovered quickly. No significant difference in portal blood flow rate existed between each group one week after the operation (P>0.05). Shortly after the transplantation the ALT and AST levels showed an increase of different degree in all dogs, which reached its peak at 24 hours after the operation. The increase in ALT and AST levels was most sharp in group V2 while most minor in group A1. The ALT and AST levels gradually returned to normal two weeks later. The difference in ALT and AST levels between every group was significant (P<0

  3. Total Thyroidectomy

    Directory of Open Access Journals (Sweden)

    Lopez Moris E

    2016-06-01

    Full Text Available Total thyroidectomy is a surgery that removes all the thyroid tissue from the patient. The suspect of cancer in a thyroid nodule is the most frequent indication and it is presume when previous fine needle puncture is positive or a goiter has significant volume increase or symptomes. Less frequent indications are hyperthyroidism when it is refractory to treatment with Iodine 131 or it is contraindicated, and in cases of symptomatic thyroiditis. The thyroid gland has an important anatomic relation whith the inferior laryngeal nerve and the parathyroid glands, for this reason it is imperative to perform extremely meticulous dissection to recognize each one of these elements and ensure their preservation. It is also essential to maintain strict hemostasis, in order to avoid any postoperative bleeding that could lead to a suffocating neck hematoma, feared complication that represents a surgical emergency and endangers the patient’s life.It is essential to run a formal technique, without skipping steps, and maintain prudence and patience that should rule any surgical act.

  4. A comparative study of reinitialization approaches of the level set method for simulating free-surface flows

    Energy Technology Data Exchange (ETDEWEB)

    Sufyan, Muhammad; Ngo, Long Cu; Choi, Hyoung Gwon [Seoul National University, Seoul (Korea, Republic of)

    2016-04-15

    Unstructured grids were used to compare the performance of a direct reinitialization scheme with those of two reinitialization approaches based on the solution of a hyperbolic Partial differential equation (PDE). The problems of moving interface were solved in the context of a finite element method. A least-square weighted residual method was used to discretize the advection equation of the level set method. The benchmark problems of rotating Zalesak's disk, time-reversed single vortex, and two-dimensional sloshing were examined. Numerical results showed that the direct reinitialization scheme performed better than the PDE-based reinitialization approaches in terms of mass conservation, dissipation and dispersion error, and computational time. In the case of sloshing, numerical results were found to be in good agreement with existing experimental data. The direct reinitialization approach consumed considerably less CPU time than the PDE-based simulations for 20 time periods of sloshing. This approach was stable, accurate, and efficient for all the problems considered in this study.

  5. A comparative study of simple methods to quantify cerebral blood flow with acetazolamide challenge by using iodine-123-IMP SPECT with one-point arterial sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, Masaki [Niigata Univ. (Japan). School of Health Sciences; Odano, Ikuo

    2000-04-01

    The aim of this study was to compare the accuracy of simplified methods for quantifying rCBF with acetazolamide challenge by using {sup 123}I-N-isopropyl-p-iodoamphetamine (IMP) and SPECT with one-point arterial sampling. After acetazolamide administration we quantified rCBF in 12 subjects by the following three methods: (a) the modified microsphere method, (b) the IMP-autoradiographic (ARG) method based on a two-compartment one-parameter model, and (c) the simplified method based on a two-compartment two-parameter model (functional IMP method). The accuracy of these methods was validated by comparing rCBF values with those obtained by the standard method: the super-early microsphere method with continuous withdrawal of arterial blood. On analyzing rCBF in each flow range (0-0.25, 0.25-0.5, 0.5-0.75 and more than 0.75 ml/g/min), rCBF values obtained by both methods (a) and (c) showed significant correlations (p<0.01) with those obtained by the standard method in every range, but rCBF values obtained by method (b) did not significantly correlated in the high flow range (0.5-0.75 and more than 0.75 ml/g/min). Method (c) was found to be the most accurate, even though it needs two serial SPECT scans. When requiring one SPECT scan, method (a) was considered to be superior to method (b) because of its accuracy, especially in high flow regions loaded with acetazolamide. (author)

  6. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

    International Nuclear Information System (INIS)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara; Sasaki, Tsukasa; Katoh, Chietsugu; Shirato, Hiroki

    2014-01-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against 15 O-H 2 O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P CT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  7. Simultaneous determination of five free and total flavonoids in rat plasma by ultra HPLC-MS/MS and its application to a comparative pharmacokinetic study in normal and hyperlipidemic rats.

    Science.gov (United States)

    Wang, Xiaofan; Zhao, Xu; Gu, Liqiang; Lv, Chunxiao; He, Bosai; Liu, Zhenzhen; Hou, Pengyi; Bi, Kaishun; Chen, Xiaohui

    2014-03-15

    A simple and rapid ultra-high performance liquid chromatography-tandem mass spectrometry (uHPLC-MS/MS) method has been developed for the simultaneous determination of five free flavonoids (amentoflavone, isorhamnetin, naringenin, kaempferol and quercetin) and their total (free and conjugated) forms, and to compare the pharmacokinetics of these active ingredients in normal and hyperlipidemic rats. The free and total forms of these flavonoids were extracted by liquid-liquid extraction with ethyl acetate. The conjugated flavonoids were deconjugated by the enzyme β-Glucuronidase and Sulfatase. Chromatographic separation was accomplished on a ZORBAX Eclipse XDB-C8 USP L7 column using gradient elution. Detection was performed on a 4000Q uHPLC-MS/MS system from AB Sciex using negative ion mode in the multiple reaction monitoring (MRM) mode. The lower limits of quantification were 2.0-5.0ng/mL for all the analytes. Intra-day and inter-day precision were less than 15% and accuracy ranged from -9.3% to 11.0%, and the mean extraction recoveries of analytes and internal standard (IS) from rat plasma were all more than 81.7%. The validated method was successfully applied to a comparative pharmacokinetic study of five free and total analytes in rat plasma. The results indicated that the absorption of five total flavonoids in hyperlipidemia group were significantly higher than those in normal group with similar concentration-time curves. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Assessment of Salivary Flow Rate and pH Among Areca Nut Chewers and Oral Submucous Fibrosis Subjects: A Comparative Study.

    Science.gov (United States)

    Abdul Khader, Nishat Fatima; Dyasanoor, Sujatha

    2015-09-01

    To assess and compare the salivary flow rate (SFR) and salivary pH among areca nut chewers, oral submucous fibrosis (OSMF) patients and apparently healthy individuals. A comparative study was conducted to assess and compare the SFR and pH among 135 outpatients (45 areca nut chewers + 45 OSMF + 45 control) at The Oxford Dental College and Research Hospital, Bangalore, India. Subjects were interviewed using structural proforma and Modified Schirmer strips and pH paper were implemented for assessing SFR and pH respectively. Statistical analysis was done using IBM SPSS ver. 21.0 software. A statistically significant increase in SFR (35.7 mm at 3rd minutes) among areca nut group and a decrease in SFR among OSMF group (23.4 mm at 3rd minutes) when compared to apparently healthy subjects (30.7 mm at 3rd minutes). The mean pH among areca nut, OSMF and control groups was 6.76, 6.82, and 6.74 respectively with no statistical significance. The observation and findings of the study clearly showed hypersalivation among areca nut group and hyposalivation among OSMF group, with no significant change in salivary pH when compared to healthy subjects.

  9. Radiation shielding and effective atomic number studies in different types of shielding concretes, lead base and non-lead base glass systems for total electron interaction: A comparative study

    International Nuclear Information System (INIS)

    Kurudirek, Murat

    2014-01-01

    Highlights: • Radiation shielding calculations for concretes and glass systems. • Assigning effective atomic number for the given materials for total electron interaction. • Glass systems generally have better shielding ability than concretes. - Abstract: Concrete has been widely used as a radiation shielding material due to its extremely low cost. On the other hand, glass systems, which make everything inside visible to observers, are considered as promising shielding materials as well. In the present work, the effective atomic numbers, Z eff of some concretes and glass systems (industrial waste containing glass, Pb base glass and non-Pb base glass) have been calculated for total electron interaction in the energy region of 10 keV–1 GeV. Also, the continuous slowing down approximation (CSDA) ranges for the given materials have been calculated in the wide energy region to show the shielding effectiveness of the given materials. The glass systems are not only compared to different types of concretes but also compared to the lead base glass systems in terms of shielding. Moreover, the obtained results for total electron interaction have been compared to the results for total photon interaction wherever possible. In general, it has been observed that the glass systems have superior properties than most of the concretes over the high-energy region with respect to the electron interaction. Also, glass systems without lead show better electron stopping than lead base glasses at some energy regions as well. Along with the photon attenuation capability, it is seen that Fly Ash base glass systems have not only greater electron stopping capability but also have greater photon attenuation especially in high energy region when compared with standard shielding concretes

  10. Radiation shielding and effective atomic number studies in different types of shielding concretes, lead base and non-lead base glass systems for total electron interaction: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Kurudirek, Murat, E-mail: mkurudirek@gmail.com

    2014-12-15

    Highlights: • Radiation shielding calculations for concretes and glass systems. • Assigning effective atomic number for the given materials for total electron interaction. • Glass systems generally have better shielding ability than concretes. - Abstract: Concrete has been widely used as a radiation shielding material due to its extremely low cost. On the other hand, glass systems, which make everything inside visible to observers, are considered as promising shielding materials as well. In the present work, the effective atomic numbers, Z{sub eff} of some concretes and glass systems (industrial waste containing glass, Pb base glass and non-Pb base glass) have been calculated for total electron interaction in the energy region of 10 keV–1 GeV. Also, the continuous slowing down approximation (CSDA) ranges for the given materials have been calculated in the wide energy region to show the shielding effectiveness of the given materials. The glass systems are not only compared to different types of concretes but also compared to the lead base glass systems in terms of shielding. Moreover, the obtained results for total electron interaction have been compared to the results for total photon interaction wherever possible. In general, it has been observed that the glass systems have superior properties than most of the concretes over the high-energy region with respect to the electron interaction. Also, glass systems without lead show better electron stopping than lead base glasses at some energy regions as well. Along with the photon attenuation capability, it is seen that Fly Ash base glass systems have not only greater electron stopping capability but also have greater photon attenuation especially in high energy region when compared with standard shielding concretes.

  11. Comparative study of laminar and turbulent flow model with different operating parameters for radio frequency-inductively coupled plasma torch working at 3  MHz frequency at atmospheric pressure

    International Nuclear Information System (INIS)

    Punjabi, Sangeeta B.; Sahasrabudhe, S. N.; Das, A. K.; Joshi, N. K.; Mangalvedekar, H. A.; Kothari, D. C.

    2014-01-01

    This paper provides 2D comparative study of results obtained using laminar and turbulent flow model for RF (radio frequency) Inductively Coupled Plasma (ICP) torch. The study was done for the RF-ICP torch operating at 50 kW DC power and 3 MHz frequency located at BARC. The numerical modeling for this RF-ICP torch is done using ANSYS software with the developed User Defined Function. A comparative study is done between laminar and turbulent flow model to investigate how temperature and flow fields change when using different operating conditions such as (a) swirl and no swirl velocity for sheath gas flow rate, (b) variation in sheath gas flow rate, and (c) variation in plasma gas flow rate. These studies will be useful for different material processing applications

  12. Alterations of total non stimulated salivary flow in patients with squamous cell carcinoma of the mouth and oropharynx submitted to hyperfractionated radiation therapy; Alteracoes do fluxo salivar total nao estimulado em pacientes portadores de carcinoma espinocelular de boca e orofaringe submetidos a radioterapia por hiperfracionamento

    Energy Technology Data Exchange (ETDEWEB)

    Guebur, Maria Isabela [Faculdades Integradas Espirita, Curitiba, PR (Brazil)]. E-mail: isabelaguebur@aol.com; Rapoport, Abrao [Hospital Heliopolis (HOSPHEL), Sao Paulo, SP (Brazil). Curso de Pos-Graduacao em Ciencias da Saude; Sassi, Laurindo Moacir [Hospital Erasto Gaertner, Curitiba, PR (Brazil). Servico de Cirurgia e Traumatologia Buco-Maxico-Facial; Oliveira, Benedito Valdecir de; Ramos, Gyl Henrique Albrecht [Hospital Erasto Gaertner, Curitiba, PR (Brazil). Servico de Cirurgia de Cabeca e Pescoco; Pereira, Jose Carlos Gasparin [Hospital Erasto Gaertner, Curitiba, PR (Brazil). Servico de Radioterapia

    2004-07-01

    Prevention and early diagnosis are actually the most effective measures that we dispose to improve the prognostic of the malignant tumors. The mouth and oropharynx tumors are treated with success, when early diagnosed. The radiotherapy is almost always one of the selected treatments for these tumors. When cancer is diagnosed in advanced stages, many a time the treatment needs to be carried out swiftly to be efficient, and consequently the radio therapist use the hyperfractionated therapy, with the patient receiving two lower doses of radiation in two sessions daily, amounting to a higher daily dosage, of about 160 cGy/2x/day. When the major salivary glands are present in the radiated field, the xerostomia appears by the second week of treatment (1500 to 2000 cGy), changing the patient's health, and causing difficulties for him to eat, speak and sleep. The objective of this study was to evaluate the quantitative alterations of the total non stimulated salivate flow of patients who underwent hyperfractionated therapy for the treatment of squamous cell carcinoma of mouth and oropharynx. Samples of twelve male patients saliva from Erasto Gaertner Hospital in Curitiba, PR, Brazil, were examined. Two samples of saliva were collected from each patient, the first one before the beginning of the radiotherapy, and the second at the end of the treatment. As a result, we obtained salivary loss in 91.7% of the patients, with a percentage of total salivary flow loss of 62.9%, registered in the second collection. We concluded that the hyperfractionated therapy causes a marked xerostomia when the major salivary glands are in the radiated field. (author)

  13. Dissolved inorganic carbon, total alkalinity, pH, nutrients and other variables collected from surface discrete sampling using flow through pump and other instruments from NOAA Ship Gordon Gunter in the U.S. East Coast during the East Coast Ocean Acidification (GU-15-04 ECOA1) from 2015-06-20 to 2015-07-23 (NCEI Accession 0157389)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains dissolved inorganic carbon, total alkalinity, pH, nutrients and other variables collected from surface discrete sampling using flow...

  14. Application of hydrocyanic acid vapor generation via focused microwave radiation to the preparation of industrial effluent samples prior to free and total cyanide determinations by spectrophotometric flow injection analysis.

    Science.gov (United States)

    Quaresma, Maria Cristina Baptista; de Carvalho, Maria de Fátima Batista; Meirelles, Francis Assis; Santiago, Vânia Maria Junqueira; Santelli, Ricardo Erthal

    2007-02-01

    A sample preparation procedure for the quantitative determination of free and total cyanides in industrial effluents has been developed that involves hydrocyanic acid vapor generation via focused microwave radiation. Hydrocyanic acid vapor was generated from free cyanides using only 5 min of irradiation time (90 W power) and a purge time of 5 min. The HCN generated was absorbed into an accepting NaOH solution using very simple glassware apparatus that was appropriate for the microwave oven cavity. After that, the cyanide concentration was determined within 90 s using a well-known spectrophotometric flow injection analysis system. Total cyanide analysis required 15 min irradiation time (90 W power), as well as chemical conditions such as the presence of EDTA-acetate buffer solution or ascorbic acid, depending on the effluent to be analyzed (petroleum refinery or electroplating effluents, respectively). The detection limit was 0.018 mg CN l(-1) (quantification limit of 0.05 mg CN l(-1)), and the measured RSD was better than 8% for ten independent analyses of effluent samples (1.4 mg l(-1) cyanide). The accuracy of the procedure was assessed via analyte spiking (with free and complex cyanides) and by performing an independent sample analysis based on the standard methodology recommended by the APHA for comparison. The sample preparation procedure takes only 10 min for free and 20 min for total cyanide, making this procedure much faster than traditional methodologies (conventional heating and distillation), which are time-consuming (they require at least 1 h). Samples from oil (sour and stripping tower bottom waters) and electroplating effluents were analyzed successfully.

  15. Pulse waveform analysis on temporal changes in ocular blood flow due to caffeine intake: a comparative study between habitual and non-habitual groups.

    Science.gov (United States)

    Ismail, Aishah; Bhatti, Mehwish S; Faye, Ibrahima; Lu, Cheng Kai; Laude, Augustinus; Tang, Tong Boon

    2018-06-06

    To evaluate and compare the temporal changes in pulse waveform parameters of ocular blood flow (OBF) between non-habitual and habitual groups due to caffeine intake. This study was conducted on 19 healthy subjects (non-habitual 8; habitual 11), non-smoking and between 21 and 30 years of age. Using laser speckle flowgraphy (LSFG), three areas of optical nerve head were analyzed which are vessel, tissue, and overall, each with ten pulse waveform parameters, namely mean blur rate (MBR), fluctuation, skew, blowout score (BOS), blowout time (BOT), rising rate, falling rate, flow acceleration index (FAI), acceleration time index (ATI), and resistive index (RI). Two-way mixed ANOVA was used to determine the difference between every two groups where p groups in several ocular pulse waveform parameters, namely MBR (overall, vessel, tissue), BOT (overall), rising rate (overall), and falling rate (vessel), all with p group, but not within the habitual group. The temporal changes in parameters MBR (vessel, tissue), skew (overall, vessel), BOT (overall, vessel), rising rate (overall), falling rate (overall, vessel), and FAI (tissue) were significant for both groups (habitual and non-habitual) in response to caffeine intake. The experiment results demonstrated caffeine does modulate OBF significantly and response differently in non-habitual and habitual groups. Among all ten parameters, MBR and BOT were identified as the suitable biomarkers to differentiate between the two groups.

  16. Comparative Advantage: Explaining Tourism Flows

    DEFF Research Database (Denmark)

    Zhang, Jie; Jensen, Camilla

    2012-01-01

    The original research article is reprinted in this volume from Edward Elgar on the Economics and Management of Tourism: ‘Ritchie and Crouch’s book The Competitive Destination: A Sustainable Tourism Perspective (CABI, 2003) has become one of the seminal works in tourism destination research and ma...... a required reader for tourism educators, graduate students and destination managers. I anticipate it will lead to yet another surge in excellent, important research.’ – Richard Perdue, Virginia Tech, US......The original research article is reprinted in this volume from Edward Elgar on the Economics and Management of Tourism: ‘Ritchie and Crouch’s book The Competitive Destination: A Sustainable Tourism Perspective (CABI, 2003) has become one of the seminal works in tourism destination research...... and management. It engendered a number of major research papers; many of which I was pleased to publish in the Journal of Travel Research. I am excited to see Geoff and Brent continuing their work with the publication of this edited book. The list of chapter authors is a “who’s who” of tourism researchers...

  17. Determination of CD4+ and CD8+ lymphocytes with the cytosphere assay: a comparative study with flow cytometry and the immunoalkaline phosphatase method

    DEFF Research Database (Denmark)

    Gernow, A; Lisse, I M; Böttiger, B

    1995-01-01

    number of CD4+ lymphocytes determined by CA showed a good correlation with results obtained by FC (correlation coefficients were 0.92 and 0.74 in Denmark and The Ivory Coast, respectively) and IA (correlation coefficients were 0.94 and 0.66 in Denmark and The Ivory Coast, respectively). However, for HIV......The proportion and absolute numbers of CD4+ and CD8+ lymphocytes in peripheral blood were determined using a new manual method, the cytosphere assay (CA). This method uses small latex beads coated with monoclonal antibodies directed against the CD4 and CD8 receptors, respectively. The CA...... was compared with two other methods for determination of T lymphocyte subsets, flow cytometry (FC) and the immunoalkaline phosphatase (IA) method, by testing HIV-seropositive and HIV-seronegative samples from Denmark (44) and Ivory Coast (79). For HIV-seropositive samples, both the proportion and the absolute...

  18. Modeling of Chromium (III) Removal from Heavy Metals Mixture Solutions in Continuous Flow Systems: A Comparative Study between BDST and Yoon -Nelson Models

    International Nuclear Information System (INIS)

    Ahmed, A.Z.

    2011-01-01

    The aim of this work is to study modeling of chromium (III) removal from aqueous solution using activated carbon as adsorbent. Studies have been conducted in a continuous fixed bed packed column under different operating conditions such as bed height, flow rate, fluid velocity and fixed adsorbent particle size. The Yoon Nelson model was applied to experimental data to predict the breakthrough curves by calculating the rate constant k and 50 % breakthrough time, θ. The Bed Depth Service Time (BDST) was applied to determine BDST constant K and the capacity of adsorbent, No. Results obtained from both models are compared with the experimental breakthrough curves and a satisfactory agreement was noticed. Therefore, the Yoon - Nelson and BDST models were found suitable for determining the parameters of the column design. The Y 000 - Nelson model was found more accurate in representing th