Macrobending loss properties of photonic crystal fibres with different air filling fractions
DEFF Research Database (Denmark)
Sørensen, Thorkild; Broeng, Jes; Bjarklev, Anders Overgaard
2001-01-01
We present experimental and theoretical analysis of macrobending losses of photonic crystal fibres with various air filling fractions. A scalar, effective-index method provides a good description of the losses for fibres with limited air filling fractions, whereas the method overestimates...... the losses for fibres with larger air filling fractions....
DEFF Research Database (Denmark)
Olesen, Uffe Høgh; Mogensen, Mette; Haedersdal, Merete
2017-01-01
Ablative fractional laser (AFXL) is an emerging method that enhances topical drug delivery. Penetrating the skin in microscopic, vertical channels, termed microscopic treatment zones (MTZs), the fractional technique circumvents the skin barrier and allows increased uptake of topically applied dru...... was overall greater for more superficial MTZs. In conclusion, vehicle type affects filling of MTZs, which may be of importance for AFXL-assisted drug delivery....
Total alkaloid content in various fractions of Tabernaemonata sphaerocarpa Bl. (Jembirit) leaves
Salamah, N.; Ningsih, D. S.
2017-11-01
Tabernaemontana sphaerocarpa Bl. (Jembirit) is one of the Apocynaceae family plants containing alkaloid compound. Traditionally, it is used as an anti-inflammatory medicine. It is found to have a new bisindole alkaloid compound that shows a potent cytotoxic activity in human cancer. This study aimed to know the total alkaloid content in some fractions of ethanolic extract of T. sphaerocarpa Bl. leaf powder was extracted by maceration method in 70% ethanol solvent. Then, the extract was fractionated in a separatory funnel using water, ethyl acetate, and hexane. The total alkaloid content in each fraction was analyzed with visible spectrophotometric methods based on the reaction with Bromocresol Green (BCG). The total alkaloids in water fraction and ethyl acetate fraction were (0.0312±0.0009)% and (0.0281±0.0014)%, respectively. Meanwhile, the total alkaloid content in hexane was not detected. The statistical analysis, performed in SPSS, resulted in a significant difference between the total alkaloids in water fraction and ethyl acetate fraction. The total alkaloid in water fraction of T. sphaerocarpa Bl. was higher than the one in ethyl acetate fraction.
International Nuclear Information System (INIS)
Miko, T.G.
2004-01-01
According to Wang Siegel has long suggested that an earlier indicator of damage to the hearts of cancer patients undergoing potentially cardiotoxic chemotherapy could be change in the left ventricular filling rate (LVFT) rather than dependence on the left ventricular ejection fraction (LVEF) as a measure for when to discontinue chemotherapy. Currently ejection fraction obtained by performing the nuclear medicine MUGA scan is the gold standard for determining further treatment of patients with these cardiotoxic agents. We are seeking to see if changes in filling rate (LVFR) are an earlier indicator of cardiotoxicity by performing a retrospective analysis of MUGA scans performed at our facility pre- and post-chemotherapy and performing a statistical analysis of changes in ejection fraction us filling rate in patients known to have cardiotoxic changes due to chemotherapy. (authors)
International Nuclear Information System (INIS)
Pan, W.; Tsui, D.C.; Pan, W.; Xia, J.; Shvarts, V.; Adams, D.E.; Xia, J.; Shvarts, V.; Adams, D.E.; Stormer, H.L.; Stormer, H.L.; Pfeiffer, L.N.; Baldwin, K.W.; West, K.W.
1999-01-01
We report ultralow temperature experiments on the obscure fractional quantum Hall effect at Landau level filling factor ν=5/2 in a very high-mobility specimen of μ=1.7x10 7 cm 2 /V s . We achieve an electron temperature as low as ∼4 mK , where we observe vanishing R xx and, for the first time, a quantized Hall resistance, R xy =h/(5/2)e 2 to within 2ppm. R xy at the neighboring odd-denominator states ν=7/3 and 8/3 is also quantized. The temperature dependences of the R xx minima at these fractional fillings yield activation energy gaps Δ 5/2 =0.11 , Δ 7/3 =0.10 , and Δ 8/3 =0.055 K . copyright 1999 The American Physical Society
International Nuclear Information System (INIS)
Figueroa-Feliciano, E.; Bandler, S.R.; Chervenak, J.; Finkbeiner, F.; Iyomoto, N.; Kelley, R.L.; Kilbourne, C.A.; Porter, F.S.; Saab, T.; Sadleir, J.; White, J.
2006-01-01
We have designed, modeled, fabricated and tested a 600μm high-fill-fraction microcalorimeter array that will be a good match to the requirements of future X-ray missions. Our devices use transition-edge sensors coupled to overhanging bismuth/copper absorbers to produce arrays with 97% or higher fill fraction. An extensive modeling effort was undertaken in order to accommodate large pixel sizes (500-1000μm) and maintain the best energy resolution possible. The finite thermalization time of the large absorber and the associated position dependence of the pulse shape on absorption position constrain the time constants of the system given a desired energy-resolution performance. We show the results of our analysis and our new pixel design, consisting of a novel TES-on-the-side architecture which creates a controllable TES-absorber conductance
Fractional statistics and fractional quantized Hall effect
International Nuclear Information System (INIS)
Tao, R.; Wu, Y.S.
1985-01-01
The authors suggest that the origin of the odd-denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which govern quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics do not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus, no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references
Use of normalized total dose to represent the biological effect of fractionated radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)
1990-03-01
There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.
Use of normalized total dose to represent the biological effect of fractionated radiotherapy
International Nuclear Information System (INIS)
Flickinger, J.C.; Kalend, A.
1990-01-01
There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab
Fractional statistics and fractional quantized Hall effect. Revision
International Nuclear Information System (INIS)
Tao, R.; Wu, Y.S.
1984-01-01
We suggest that the origin of the odd denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which governs quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics does not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references
International Nuclear Information System (INIS)
Ciftja, O.
1999-01-01
The microscopic approach for studying the half-filled state of the fractional quantum Hall effect is based on the idea of proposing a trial Fermi wave function of the Jastrow-Slater form, which is then fully projected onto the lowest Landau level. A simplified starting point is to drop the projection operator and to consider an unprojected wave function. A recent study claims that such a wave function approximated in a Jastrow form may still constitute a good starting point on the study of the half-filled state. In this paper we formalize the effective hypernetted-chain approximation and apply it to the unprojected Fermi wave function, which describes the even-denominator-filling states. We test the above approximation by using the Fermi hypernetted-chain theory, which constitutes the natural choice for the present case. Our results suggest that the approximation of the Slater determinant of plane waves as a Jastrow wave function may not be a very accurate approximation. We conclude that the lowest Landau-level projection operator cannot be neglected if one wants a better quantitative understanding of the phenomena. copyright 1999 The American Physical Society
Lim, Adrian C; Lowe, Patricia M
2011-05-01
For volume restoration of the face, hyaluronic acid is conventionally injected through long, large-bore, 18-gauge needles because of the higher viscosity subtypes required. These hyaluronic acids are either more highly cross-linked or larger in particle size than the less-viscous subtypes. The microdepot injection technique involves using the 31-gauge BD insulin syringe (Becton-Dickinson, North Ryde, NSW Australia) to deposit small amounts of filler (0.05-0.1 mL) throughout the area of volume loss. The procedure is extremely well tolerated, requiring only topical and ice anaesthesia. Using this method, volume restoration can be achieved naturally and progressively over a period of time. Fractional filling every 3-4 months is continued until the desired level of volume correction is attained. Patients undergoing fractional filling followed over a 12-month period did not indicate any observable compromise in filler longevity, even when highly viscous hyaluronic acid fillers were injected through small-bore, 31-gauge insulin syringes. © 2011 The Authors. Australasian Journal of Dermatology © 2011 The Australasian College of Dermatologists.
Fractional-Order Total Variation Image Restoration Based on Primal-Dual Algorithm
Chen, Dali; Chen, YangQuan; Xue, Dingyu
2013-01-01
This paper proposes a fractional-order total variation image denoising algorithm based on the primal-dual method, which provides a much more elegant and effective way of treating problems of the algorithm implementation, ill-posed inverse, convergence rate, and blocky effect. The fractional-order total variation model is introduced by generalizing the first-order model, and the corresponding saddle-point and dual formulation are constructed in theory. In order to guarantee $O(1/{N}^{2})$ conv...
Fractionated homogenous total-body irradiation prior to bone marrow transplantation
Energy Technology Data Exchange (ETDEWEB)
Duehmke, E; Brix, F; Hebbinghaus, D; Jensen, M; Wendhausen, H; Schmitz, N
1985-03-01
At the University of Kiel, myeloid and acute lymphatic leukemia is treated since 1983 by total-body irradiation applied prior to bone marrow transplantation. Dose deviations in the midplane caused by the irregular surface and tissue inhomogeneities of the patient are reduced down to +-3.5% compared to the central ray, with the help of CT-based individual compensators. This method prevents above all an excessive dose to the lungs. The radiobiologic advantages of fractionated irradiation have been employed for all patients treated hitherto (n = 9). At present, a total body dose of 12 Gy in six fractions is applied within three days. There were no undesired acute radiogenic reactions except a mild acute mucositis found in all patients. Chronic side effects, especially in the lungs, were not demonstrated, too. However, the average follow-up time of 149 days has been rather short. One patient died from relapse of leukemia after a total dose of 10 Gy, another patient died because the transplanted bone marrow was rejected, and a third died from catheter sepsis. Six out of nine patients are in complete remission with a maximum index of Karnofsky. The limited experiences gained hitherto show that the homogeneous accelerated-fractionated total-body irradiation offers essential advantages compared to non-compensated single dose irradiation with respect to the prevention of undesired radiogenic effects in sound tissues and that its therapeutic efficacy is at least the same.
Directory of Open Access Journals (Sweden)
Deepak Kumar
2012-10-01
Full Text Available Objective: To investigate the effect and evaluation of Anti-hyperlipidemic activity guided subfraction isolated from total methanolic extract of Bauhinia variegata (Linn. leaves on Triton WR-1339 induced hyperlipidemic rats. Methods: Column chromatographic fractionation of butanol fraction of total methanol extract of leaves of Bauhinia variegata (Linn. yields four subfractions (sub-fraction A-D. All sub-fractions tested for their anti-hyperlipidemic activity. Subfractions administered at a dose of 65 mg/kg (oral to the Triton WR-1339 induced hyperlipidemic rats and total cholesterol, triglycerides, HDL, LDL and VLDL level in the blood were checked. Results: Sub-fraction D showed significant reduction (P<0.05 among four sub-fraction in comparison with standard drug fenofibrate. Conclusions: From the above study it could be concluded that butanol sub-fraction D of Bauhinia variegata (Linn. not only have resulted in significant reduction in cholesterol, triglyceride, LDL, VLDL level but also increases the HDL level at a reduced dose level.
STELLAR AND TOTAL BARYON MASS FRACTIONS IN GROUPS AND CLUSTERS SINCE REDSHIFT 1
International Nuclear Information System (INIS)
Giodini, S.; Pierini, D.; Finoguenov, A.; Pratt, G. W.; Boehringer, H.; Leauthaud, A.; Guzzo, L.; Aussel, H.; Bolzonella, M.; Capak, P.; Elvis, M.; Hasinger, G.; Ilbert, O.; Kartaltepe, J. S.; Koekemoer, A. M.; Lilly, S. J.; Massey, R.; Rhodes, J.; Salvato, M.; McCracken, H. J.
2009-01-01
We investigate if the discrepancy between estimates of the total baryon mass fraction obtained from observations of the cosmic microwave background (CMB) and of galaxy groups/clusters persists when a large sample of groups is considered. To this purpose, 91 candidate X-ray groups/poor clusters at redshift 0.1 ≤ z ≤ 1 are selected from the COSMOS 2 deg 2 survey, based only on their X-ray luminosity and extent. This sample is complemented by 27 nearby clusters with a robust, analogous determination of the total and stellar mass inside R 500 . The total sample of 118 groups and clusters with z ≤ 1 spans a range in M 500 of ∼10 13 -10 15 M sun . We find that the stellar mass fraction associated with galaxies at R 500 decreases with increasing total mass as M -0.37±0.04 500 , independent of redshift. Estimating the total gas mass fraction from a recently derived, high-quality scaling relation, the total baryon mass fraction (f stars+gas 500 = f stars 500 + f gas 500 ) is found to increase by ∼25%, when M 500 increases from (M) = 5 x 10 13 M sun to (M) = 7 x 10 14 M sun . After consideration of a plausible contribution due to intracluster light (11%-22% of the total stellar mass) and gas depletion through the hierarchical assembly process (10% of the gas mass), the estimated values of the total baryon mass fraction are still lower than the latest CMB measure of the same quantity (WMAP5), at a significance level of 3.3σ for groups of (M) = 5 x 10 13 M sun . The discrepancy decreases toward higher total masses, such that it is 1σ at (M) = 7 x 10 14 M sun . We discuss this result in terms of nongravitational processes such as feedback and filamentary heating.
Human Milk MicroRNA and Total RNA Differ Depending on Milk Fractionation.
Alsaweed, Mohammed; Hepworth, Anna R; Lefèvre, Christophe; Hartmann, Peter E; Geddes, Donna T; Hassiotou, Foteini
2015-10-01
MicroRNA have been recently discovered in human milk signifying potentially important functions for both the lactating breast and the infant. Whilst human milk microRNA have started to be explored, little data exist on the evaluation of sample processing, and analysis to ensure that a full spectrum of microRNA can be obtained. Human milk comprises three main fractions: cells, skim milk, and lipids. Typically, the skim milk fraction has been measured in isolation despite evidence that the lipid fraction may contain more microRNA. This study aimed to standardize isolation of microRNA and total RNA from all three fractions of human milk to determine the most appropriate sampling and analysis procedure for future studies. Three different methods from eight commercially available kits were tested for their efficacy in extracting total RNA and microRNA from the lipid, skim, and cell fractions of human milk. Each fraction yielded different concentrations of RNA and microRNA, with the highest quantities found in the cell and lipid fractions, and the lowest in skim milk. The column-based phenol-free method was the most efficient extraction method for all three milk fractions. Two microRNAs were expressed and validated in the three milk fractions by qPCR using the three recommended extraction kits for each fraction. High expression levels were identified in the skim and lipid milk factions for these microRNAs. These results suggest that careful consideration of both the human milk sample preparation and extraction protocols should be made prior to embarking upon research in this area. © 2015 The Authors. Journal of Cellular Biochemistry Published by Wiley Periodicals, Inc.
International Nuclear Information System (INIS)
Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.
1993-01-01
The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs
de Boer, Friso A; Sariali, Elhadi
2017-05-12
The femoral canal fill between an anatomic and a straight prosthesis design in cementless total hip arthroplasty (THA) was compared. We hypothesised that the anatomic SPS stem has higher proximal fill and lesser distal fill than the straight stem. The femoral canal fill was measured on 3 months routine postoperative x-rays at 5 levels of the stem in 50 consecutive patients, aged 35-83 years, who underwent 56 THA procedures by a single surgeon in this hospital. 22 patients received a straight design Ceramconcept Global stem, 34 patients received an anatomic design Symbios SPS stem. Both anteroposterior (AP) and lateral x-rays were combined to suggest a 3-D measurement. On the AP x-rays, the canal fill was significantly higher using the anatomic design stem at the proximal measurement levels, and was significantly higher at the distal levels using the straight stem. With the AP and lateral x-rays combined, the canal fill at the proximal levels was also significantly higher in the anatomic groups, nonsignificantly lower at the central level and significantly lower at the distal levels. In THA surgery, achieving high fill at the metaphysis of the femur and less fill at the diaphysis has been suggested to result in satisfactory outcome and high stability of the prosthesis. This study demonstrated that, compared to straight stem design, an anatomically designed stem has a significantly higher metaphyseal femoral canal fill.
Directory of Open Access Journals (Sweden)
Marwa Ben Manaa
2016-07-01
Full Text Available Carbazole-based molecular glasses have emerged as a promising alternative to the widely used hole-transporting materials (HTM spiro-OMeTAD in solid-state dye-sensitized solar cells (DSSCs. The pore filling fraction (PFF of the mesoporous TiO2 layer by the HTM appears as a key parameter determining the final efficiency of a DSSC. In this work, the pore-filling properties of a family of carbazole-based HTMs are investigated for the first time and the photovoltaic behavior of DSSC devices (fabricated using the D102 dye is discussed in light of the present findings. It is found that N-aryl substituted 3,6-bis(diphenylaminyl-carbazole derivatives exhibit relatively low PFF of ca. 60%. Methoxy groups on the diphenylamine moieties have little influence on the PFF, indicating that the strong enhancement in power conversion efficiency (PCE is not related to an improved filling of the pores by the HTM. N-alkylated HTMs lead to higher PFF, increasing with the alkyl chain length, up to 78%.
International Nuclear Information System (INIS)
Ansari, N.; Tehranchi, M.M.
2010-01-01
Study of the optical properties of the one-dimensional defective photonic crystals using the gap map is improving through the emergence of new analytical methods, which are easy and without any physical restrictions. Gap map is able to monitor the changes in the defect mode frequencies and photonic band gap regions as a function of filling fractions, and all visible spectra in a single graphic presentation. In this paper, by utilizing a novel technique based on Green's function method for analyzing the defect modes, the gap map and gap closing point of a one-dimensional defective photonic crystal have been demonstrated. This method enables study of the defect modes inside the omnidirectional band gap, which is an important object in the designing of the optical filters. Moreover, as a designing criterion, obtaining the gap closing points inside the gap map enables finding of some filling fraction intervals that each one contains several distinct omnidirectional band gaps simultaneously, using a single photonic crystal. This method has been employed for the design of an optical filter at 1.3 and 1.55 μm, which is applicable for telecommunication.
International Nuclear Information System (INIS)
Abdel-Sabour, M.F.; Abdou, F.M.; Elwan, I.M.; Al-Salama, Y.J.
2003-01-01
Fifteen soil samples were chosen from different locations (five different locations at north greater Cairo, Egypt to represent different soils (alluvial and sandy) as well as different source of contaminated wastewater (sewage and industrial effluent). Using sequential extraction technique (extracting the soil with different solutions, which is designed to separate metal fractions), Cr was separated into six operationally defined fractions water soluble, exchangeable, carbonate bound, Fe-Mn oxides bound, organic bound and residual fractions. Result of soil total-Cr indicated the serious accumulation of Cr in soils subjected to prolonged irrigation with contaminated wastewater. As it could seen, total-Cr in the tested contaminated soils exceeds the permissible levels (75-100)ppm Cr by several order of magnitude particularly at the surface and subsurface layers. The highest accumulation of total Cr down to depth 60 cm was observed in case of soil E. Data showed that values of total Cr determined by NAA method were always higher than the relevant values determined either by AAS or those calculated after the sequential extraction method. T-test analysis showed the significant difference between NAA and either AAS or sequential extraction methods. Although T-test analysis showed that were significant differences between total content in soils as determined by destructive (AAS or SUM) and non-destructive (NAA) analytical techniques however, strong liner relation between NAA and other tested methods was obtained. Chromium distribution between different extractants shows that the greatest amounts are found in the residual and Occluded in Fe and Mn-Oxides fractions followed by carbonate or organic fractions. In most cases the proportion of all tested Cr-forms has increased in contaminated soil layers with higher enrichment in organically bound Cr, occluded in Fe and Mn oxides, carbonate exchangeable and soluble fractions. Results indicate that soil properties have a
Total Phenol amd Flavonoid contents of Crude Extract and Fractions ...
African Journals Online (AJOL)
Phenolic compounds are numerous in plants and are essential part of human diet. Picralima nitida has been extensively used in African folk medicine especially in West Africa. The present study evaluated the total phenolic and flavonoid contents of the extract and fractions of Picralima nitida. The methanol extracts of P.
Performance of compact TES arrays with integrated high-fill-fraction X-ray absorbers
International Nuclear Information System (INIS)
Lindeman, Mark A.; Bandler, Simon; Brekosky, Regis P.; Chervenak, James A.; Figueroa-Feliciano, Enectali; Finkbeiner, Fred M.; Kelley, Richard L.; Saab, Tarek; Stahle, Caroline K.; Talley, D.J.
2004-01-01
We have recently produced and tested two-dimensional arrays of Mo/Au transition-edge-sensor (TES) calorimeters with Bi/Cu absorbers. The arrays represent a significant step towards meeting the specifications of NASA's Constellation-X mission. The calorimeters are compactly spaced within 5x5 arrays of 250 μm square pixels necessary for an angular resolution of 5 arcsec. Lithographically produced absorbers hang over the substrate and wiring between the TESs for high filling fraction and high quantum efficiency. We designed the calorimeters with heat capacities and thermal couplings such that X-rays produce pulses with fall times of approximately 300 μs to allow relatively high count rates with low dead time. We read out up to four of the pixels simultaneously. The arrays demonstrated very good energy resolution (5 eV at 1.5 keV and 7 eV at 6 keV) and little crosstalk between neighboring pixels
Dose rate and dose fractionation studies in total body irradiation of dogs
International Nuclear Information System (INIS)
Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.
1979-01-01
Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients
International Nuclear Information System (INIS)
Wu Liangyu; Chen Lienwen; Liu Chiaming
2009-01-01
This study theoretically and experimentally investigates the acoustic pressure in the cavity of a 2D sonic crystal. Such crystals are composed of polymethyl methacrylate cylinders with a square array embedded in air background. The plane wave expansion method and the supercell calculation are employed to calculate the band structure and obtain the defect band. The finite element method is adopted to simulate the pressure field in the sonic crystal and calculate the pressure in the middle of the cavity as a function of frequency. The effects of sizes and filling fractions are investigated, and the quality factor of the cavity is discussed. The measured spectra and pressures in the defect of the sonic crystal demonstrate that the acoustic waves can be localized in the defect at the resonant frequency
Immunosuppression by fractionated total lymphoid irradiation in collagen arthritis
International Nuclear Information System (INIS)
McCune, W.J.; Buckley, J.A.; Belli, J.A.; Trentham, D.E.
1982-01-01
Treatments with fractionated total lymphoid irradiation (TLI) and cyclophosphamide were evaluated for rats injected with type II collagen. Preadministration of TLI and repeated injections of cyclophosphamide suppressed the severity of arthritis and lowered antibody titers to collagen significantly. TLI initiated at the onset of collagen arthritis decreased humoral and cellular responses to collagen but did not affect the severity of arthritis. These data demonstrate that both TLi and cyclophosphamide are immunosuppressive in an experimentally inducible autoimmune disease
Notø, Hilde P; Nordby, Karl-Christian; Eduard, Wijnand
2016-05-01
The aims of this study were to examine the relationships and establish conversion factors between 'total' dust, respirable, thoracic, and inhalable aerosol fractions measured by parallel personal sampling on workers from the production departments of cement plants. 'Total' dust in this study refers to aerosol sampled by the closed face 37-mm Millipore filter cassette. Side-by-side personal measurements of 'total' dust and respirable, thoracic, and inhalable aerosol fractions were performed on workers in 17 European and Turkish cement plants. Simple linear and mixed model regressions were used to model the associations between the samplers. The total number of personal samples collected on 141 workers was 512. Of these 8.4% were excluded leaving 469 for statistical analysis. The different aerosol fractions contained from 90 to 130 measurements and-side-by side measurements of all four aerosol fractions were collected on 72 workers.The median ratios between observed results of the respirable, 'total' dust, and inhalable fractions relative to the thoracic aerosol fractions were 0.51, 2.4, and 5.9 respectively. The ratios between the samplers were not constant over the measured concentration range and were best described by regression models. Job type, position of samplers on left or right shoulder and plant had no substantial effect on the ratios. The ratios between aerosol fractions changed with different air concentrations. Conversion models for estimation of the fractions were established. These models explained a high proportion of the variance (74-91%) indicating that they are useful for the estimation of concentrations based on measurements of a different aerosol fraction. The calculated uncertainties at most observed concentrations were below 30% which is acceptable for comparison with limit values (EN 482, 2012). The cement industry will therefore be able to predict the health related aerosol fractions from their former or future measurements of one of the
Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.
Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan
2017-12-01
To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.
International Nuclear Information System (INIS)
Walma, E.P.; Klapwijk, W.M.; Miller, A.M.
1982-01-01
In most cases, bone marrow transplantation is preceded by a conditioning regimen employing irradiation and/or cytotoxic drugs. The authors are searching for better fractionation schedules in order to optimize the conditioning regimen prior to transplantation of stem-cell-enriched bone marrow. They have determined damage to the gastrointestinal tract in dogs and mice after total body irradiation in mice and dogs following a number of fractionation schedules, and these results are presented. The schedules were chosen such as to minimize the interval between irradiation and the bone marrow transplantation and to maximize clinical feasibility. (Auth./C.F.)
Directory of Open Access Journals (Sweden)
Nina Ching Y. Wang
2012-01-01
Full Text Available Both the Massachusetts Department of Environmental Protection (MADEP and the Total Petroleum Hydrocarbon Criteria Working Group (TPHCWG developed fraction-based approaches for assessing human health risks posed by total petroleum hydrocarbon (TPH mixtures in the environment. Both organizations defined TPH fractions based on their expected environmental fate and by analytical chemical methods. They derived toxicity values for selected compounds within each fraction and used these as surrogates to assess hazard or risk of exposure to the whole fractions. Membership in a TPH fraction is generally defined by the number of carbon atoms in a compound and by a compound's equivalent carbon (EC number index, which can predict its environmental fate. Here, we systematically and objectively re-evaluate the assignment of TPH to specific fractions using comparative molecular field analysis and hierarchical clustering. The approach is transparent and reproducible, reducing inherent reliance on judgment when toxicity information is limited. Our evaluation of membership in these fractions is highly consistent (̃80% on average across various fractions with the empirical approach of MADEP and TPHCWG. Furthermore, the results support the general methodology of mixture risk assessment to assess both cancer and noncancer risk values after the application of fractionation.
Directory of Open Access Journals (Sweden)
Sueli Mendonça-Netto
Full Text Available The purpose of the present study was to evaluate the effects of total tertiary alkaloid fraction (TTAF of Cissampelos sympodialis Eichler (Menispermaceae on two animal models of depression: a forced swim test and b reserpine test. Treatment of mice with TTAF (12.5 mg/kg reduced the total immobility time. It also reversed the reserpine-induced hypothermia, demonstrating an antidepressant effect in both models. Additionally, TTAF treatment did not modify the ambulation and rearing evaluated in open field test in order to investigate if the immobility time reduction found in the forced swimming test was caused by locomotive activity stimulation. Since warifteine is one of the main alkaloids present in the TTAF of C. sympodialis, and it has inhibitory activity of the phosphodiesterase enzyme, it may be responsible by the antidepressant effect found in the fraction studied.
Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich
2016-07-01
A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Therapeutic use of fractionated total body and subtotal body irradiation
International Nuclear Information System (INIS)
Loeffler, R.K.
1981-01-01
Ninety-one patients were treated using fractionated subtotal body (STBI) or total body irradiation (TBI). These patients had generalized lymphomas, Hodgkin's disease, leukemias, myelomas, seminomas, or oat-cell carcinomas. Subtotal body irradiation is delivered to the entire body, except for the skull and extremities. It was expected that a significantly higher radiation dose could be administered with STBI than with TBI. A five- to ten-fold increase in tolerance for STBI was demonstrated. Many of these patients have had long-term emissions. There is little or no treatment-induced symptomatology, and no sanctuary sites
International Nuclear Information System (INIS)
Ahmad, Rozilawati; Hoogeman, Mischa S.; Quint, Sandra; Mens, Jan Willem; Pree, Ilse de; Heijmen, Ben J.M.
2008-01-01
Background and Purpose: For cervical cancer patients, bladder filling variations may result in inadequate EBRT target coverage, unless large safety margins are used. For a group of patients who received full bladder instructions, inter-fraction variations and time trends in bladder volume were quantified, and a 3D ultrasound (US) scanner was tested for on-line bladder volume measurements. Methods and materials: For 24 patients, the bladder volume was measured with US at the time of the planning CT scan, and twice weekly during the course of RT. Comparisons of US with planning CT were used to assess the bladder scanner accuracy. Patients were treated in prone on a belly board, EPID images were acquired to correlate set-up errors with bladder filling variations. Results: Measured US and CT bladder volumes were strongly correlated (R = 0.97, slope 1.1 ± 0.1). The population mean bladder volume at planning of 378 ± 209 ml (1 SD) reduced to 109 ± 88 ml (1 SD) in week 6, a reduction by 71% (average reduction 46 ml/week), revealing a large inter-fraction time trend. Intra-patient variation in bladder volume during RT was 168 ml (1 SD) (range 70-266 ml). Rotation around the LR axis was significantly correlated with bladder volume changes. Conclusions: Despite a full bladder instruction, bladder volumes reduced dramatically during treatment, implying large time trends in target position of these patients. The portable US scanner provides a quick and reliable measurement of the bladder volume, which might assist future online treatment adaptation
Fill Rates of Single-Stage and Multistage Supply Systems
Matthew J. Sobel
2004-01-01
A supply system's fill rate is the fraction of demand that is met from on-hand inventory. This paper presents formulas for the fill rate of periodic review supply systems that use base-stock-level policies. The first part of the paper contains fill-rate formulas for a single-stage system and general distributions of demand. When demand is normally distributed, an exact expression uses only the standard normal distribution and density functions, and a good approximation uses only the standard ...
Benefits of online in vivo dosimetry for single-fraction total body irradiation
Energy Technology Data Exchange (ETDEWEB)
Eaton, David J., E-mail: davideaton@nhs.net [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Warry, Alison J. [Department of Radiotherapy Physics, University College London Hospital, London (United Kingdom); Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H. [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)
2014-01-01
Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.
Benefits of online in vivo dosimetry for single-fraction total body irradiation
International Nuclear Information System (INIS)
Eaton, David J.; Warry, Alison J.; Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H.
2014-01-01
Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources
Unconventional fractional quantum Hall effect in monolayer and bilayer graphene
Jacak, Janusz; Jacak, Lucjan
2016-01-01
The commensurability condition is applied to determine the hierarchy of fractional fillings of Landau levels in monolayer and in bilayer graphene. The filling rates for fractional quantum Hall effect (FQHE) in graphene are found in the first three Landau levels in one-to-one agreement with the experimental data. The presence of even denominator filling fractions in the hierarchy for FQHE in bilayer graphene is explained. Experimentally observed hierarchy of FQHE in the first and second Landau levels in monolayer graphene and in the zeroth Landau level in bilayer graphene is beyond the conventional composite fermion interpretation but fits to the presented nonlocal topology commensurability condition. PMID:27877866
Directory of Open Access Journals (Sweden)
MARCELO RIBEIRO VILELA PRADO
2016-01-01
Full Text Available The evaluation of land use and management by the measurement of soil organic matter and its fractions has gained attention since it helps in the understanding of the dynamics of their contribution to soil productivity, especially in tropical environments. This study was conducted in the municipality of Colorado do Oeste, state of Rondônia, Brazil and its aim was to determinethe quantity of organic carbon and total nitrogen in the light and heavy fractions of organic matter in the surface layers of a typic hapludalf under different land use systems: Native Forest: open evergreen forest, reference environment; Agroforestry System 1: teak (Tectona grandis LF and kudzu (Pueraria montana; Agroforestry System 2: coffee (Coffea canephora, marandu palisade grass (Brachiaria brizantha cv. Marandu, “pinho cuiabano” (Parkia multijuga, teak and kudzu.; Agroforestry System 3: teak and cocoa (Theobroma cacao; Silvopasture System: teak, cocoa and marandu palisade grass; and Extensive Grazing System: marandu palisade grass. The experimental design was a randomized block in split-split plots (use systems versus soil layers of 0-0.05 and 0.05-0.10 m with three replications. The results showed that relative to Native Forest, the Agroforestry System 2 had equal- and greater amounts of organic carbon and total nitrogen respectively (light and heavy fractions in the soil organic matter, with the light fraction being responsible for storage of approximately 45% and 70% of the organic carbon and total nitrogen, respectively. Therefore, the light densimetric fraction proved to be useful in the early identification of the general decline of the soil organic matter in the land use systems evaluated.
International Nuclear Information System (INIS)
Pak, A.; Dewald, E. L.; Landen, O. L.; Milovich, J.; Strozzi, D. J.; Berzak Hopkins, L. F.; Bradley, D. K.; Divol, L.; Ho, D. D.; MacKinnon, A. J.; Meezan, N. B.; Michel, P.; Moody, J. D.; Moore, A. S.; Schneider, M. B.; Town, R. P. J.; Hsing, W. W.; Edwards, M. J.
2015-01-01
Temporally resolved measurements of the hohlraum radiation flux asymmetry incident onto a bismuth coated surrogate capsule have been made over the first two nanoseconds of ignition relevant laser pulses. Specifically, we study the P2 asymmetry of the incoming flux as a function of cone fraction, defined as the inner-to-total laser beam power ratio, for a variety of hohlraums with different scales and gas fills. This work was performed to understand the relevance of recent experiments, conducted in new reduced-scale neopentane gas filled hohlraums, to full scale helium filled ignition targets. Experimental measurements, matched by 3D view factor calculations, are used to infer differences in symmetry, relative beam absorption, and cross beam energy transfer (CBET), employing an analytic model. Despite differences in hohlraum dimensions and gas fill, as well as in laser beam pointing and power, we find that laser absorption, CBET, and the cone fraction, at which a symmetric flux is achieved, are similar to within 25% between experiments conducted in the reduced and full scale hohlraums. This work demonstrates a close surrogacy in the dynamics during the first shock between reduced-scale and full scale implosion experiments and is an important step in enabling the increased rate of study for physics associated with inertial confinement fusion
Pak, A.; Dewald, E. L.; Landen, O. L.; Milovich, J.; Strozzi, D. J.; Berzak Hopkins, L. F.; Bradley, D. K.; Divol, L.; Ho, D. D.; MacKinnon, A. J.; Meezan, N. B.; Michel, P.; Moody, J. D.; Moore, A. S.; Schneider, M. B.; Town, R. P. J.; Hsing, W. W.; Edwards, M. J.
2015-12-01
Temporally resolved measurements of the hohlraum radiation flux asymmetry incident onto a bismuth coated surrogate capsule have been made over the first two nanoseconds of ignition relevant laser pulses. Specifically, we study the P2 asymmetry of the incoming flux as a function of cone fraction, defined as the inner-to-total laser beam power ratio, for a variety of hohlraums with different scales and gas fills. This work was performed to understand the relevance of recent experiments, conducted in new reduced-scale neopentane gas filled hohlraums, to full scale helium filled ignition targets. Experimental measurements, matched by 3D view factor calculations, are used to infer differences in symmetry, relative beam absorption, and cross beam energy transfer (CBET), employing an analytic model. Despite differences in hohlraum dimensions and gas fill, as well as in laser beam pointing and power, we find that laser absorption, CBET, and the cone fraction, at which a symmetric flux is achieved, are similar to within 25% between experiments conducted in the reduced and full scale hohlraums. This work demonstrates a close surrogacy in the dynamics during the first shock between reduced-scale and full scale implosion experiments and is an important step in enabling the increased rate of study for physics associated with inertial confinement fusion.
Energy Technology Data Exchange (ETDEWEB)
Pak, A.; Dewald, E. L.; Landen, O. L.; Milovich, J.; Strozzi, D. J.; Berzak Hopkins, L. F.; Bradley, D. K.; Divol, L.; Ho, D. D.; MacKinnon, A. J.; Meezan, N. B.; Michel, P.; Moody, J. D.; Moore, A. S.; Schneider, M. B.; Town, R. P. J.; Hsing, W. W.; Edwards, M. J. [Lawrence Livermore National Laboratory, Livermore, California, 94550 (United States)
2015-12-15
Temporally resolved measurements of the hohlraum radiation flux asymmetry incident onto a bismuth coated surrogate capsule have been made over the first two nanoseconds of ignition relevant laser pulses. Specifically, we study the P2 asymmetry of the incoming flux as a function of cone fraction, defined as the inner-to-total laser beam power ratio, for a variety of hohlraums with different scales and gas fills. This work was performed to understand the relevance of recent experiments, conducted in new reduced-scale neopentane gas filled hohlraums, to full scale helium filled ignition targets. Experimental measurements, matched by 3D view factor calculations, are used to infer differences in symmetry, relative beam absorption, and cross beam energy transfer (CBET), employing an analytic model. Despite differences in hohlraum dimensions and gas fill, as well as in laser beam pointing and power, we find that laser absorption, CBET, and the cone fraction, at which a symmetric flux is achieved, are similar to within 25% between experiments conducted in the reduced and full scale hohlraums. This work demonstrates a close surrogacy in the dynamics during the first shock between reduced-scale and full scale implosion experiments and is an important step in enabling the increased rate of study for physics associated with inertial confinement fusion.
Directory of Open Access Journals (Sweden)
Yulong Li
2015-11-01
Full Text Available For filled skutterudites, element Yb is one of the most common and important fillers. However, the optimal carrier concentration range in Y bxCo4Sb12 filled skutterudites has not been determined as a result of the low Yb filling fraction limit. In this study, a non-equilibrium fabrication process (MS-SPS process, consisting of a melt-spinning method and a spark plasma sintering technique, has been applied to prepare Y bxCo4Sb12 samples. The Yb filling fraction is successfully extended to 0.35, which provides the possibility to clarify the optimal carrier concentration range for Yb-filled skutterudites. High carrier concentrations, with a maximum of around 1 × 1021 cm−3, were achieved in the MS-SPS Y bxCo4Sb12 samples due to the significantly enhanced Yb filling fractions. The phase compositions, lattice parameters, electrical and thermal transport properties of the MS-SPS Y bxCo4Sb12 samples with high carrier concentrations were systematically investigated. An optimal carrier concentration range of around 5 ∼ 6 × 1020 cm−3, corresponding to the actual Yb filling fraction of around 0.21∼0.26, has been determined, which displays the highest thermoelectric performance in Y bxCo4Sb12 thermoelectric materials.
Long-term survival of skin allografts in mice treated with fractionated total lymphoid irradiation
International Nuclear Information System (INIS)
Slavin, S.; Strober, S.; Fuks, Z.; Kaplan, H.S.
1976-01-01
Treatment of recipient Balb/c mice with fractionated, high-dose total lymphoid irradiation, a procedure commonly used in the therapy of human malignant lymphomas, resulted in fivefold prolongation of the survival of C57BL/Ka skin allografts despite major histocompatibility differences between the strains (H-2/sup d/ and H-2/sup b/, respectively). Infusion of 10 7 (C57BL/Ka x Balb/c)F 1 bone marrow cells after total lymphoid irradiation further prolonged C57BL/Ka skin graft survival to more than 120 days. Total lymphoid irradiation may eventually prove useful in clinical organ transplantation
International Nuclear Information System (INIS)
Gale, R.P.; Opelz, G.; Feig, S.
1979-01-01
The addition of low doses of fractionated total body irradiation and a radiosensitizing agent to more conventional doses of total body irradiation was well tolerated but did not improve the antileukemic effect. The DAFT regimen was not associated with a higher incidence of GVHD or interstitial pneumonitis. This observation has led us to consider escalation of the dose of FTBI in our next clinical trial
Directory of Open Access Journals (Sweden)
Rima Munawaroh
2018-04-01
Full Text Available On Timor island, Nusa Tenggara Timur, faloak barks (Sterculia quadrifida R.Br. has been used empirically to restore stamina. Faloak bark ethanolic extract proved to have immunomodulatory activity in vitro, which can increase macrophage phagocytosis activity. This research aimed: (i to determine the immunomodulatory active fraction of faloak bark ethanolic extract, (ii to determine the total flavonoid contents of faloak extract and fractions, and (iii to evaluate the correlation of the total flavonoid contents of those extract and fractions with their macrophage phagocytosis activity. The simplisia powder is macerated with 96% ethanol. The extract was dissolved in methanol:water (9:1v/v was then subsequently partitioned with n-hexane, ethyl acetate, and water to obtain n-hexane fraction, ethyl acetate fraction, water fraction, and insoluble fraction. Faloak extract and fractions at concentration 62,5; 125; 250; 500μg/mL were tested for their effect on the peritoneal macrophage phagocytosis of Balb/c mice in vitro by the latex beads method. Phagocytosis capacity and phagocytosis index were analyzed using one-way anova and post hoc Tukey HSD test with 95% confidence level. The results showed that ethyl acetate fraction had the highest macrophage phagocytosis capacity and the highest total flavonoid content compared to other fractions. The highest macrophage phagocytosis capacity of ethyl acetate fraction at concentration of 250 μg/mL was 51,94±4,67%, this value was significantly different from cell control (7,50±1,29%, negative controls of 0,0625% dimethylsulphoxide (6,25±0,36%, as well as positive control of 200 μg/mL echinaceae extract syrup® (9,97±0,33%. The total flavonoid content of ethyl acetate fraction determined by aluminum chloride method was 4,290±0.029 mg of quercetin equivalent/g fraction. There was a positive and strong correlation between the total flavonoid content of these extract and fractions with their macrophage
International Nuclear Information System (INIS)
Najarian, J.S.; Ferguson, R.M.; Sutherland, D.E.; Slavin, S.; Kim, T.; Kersey, J.; Simmons, R.L.
1982-01-01
Twenty-two patients at high risk to reject renal allografts have been treated with fractionated total lymphoid irradiation (FTLI) prior to transplantation of primary (2), secondary (16) or tertiary (4) renal allografts. All patients undergoing retransplantation had rapidly rejected previous grafts. At 24 months following transplantation, 72% of grafts were functioning in the TLI group compared with a 38% graft function in an historical control group of recipients receiving secondary or tertiary grafts and treated with conventional immunosuppression. Important variables in determining success of transplantation following fractionated TLI include the dose of TLI, the interval from radiation to transplantation, and maintenance post-transplant immunosuppressive therapy. Optimal results were achieved with 2500 rads delivered in 100 rad fractions followed by transplantation within two weeks, and a tapering prednisone schedule and maintenance azathioprine post-transplantation. Seventeen patients had significant complications of the radiation treatment and there was one death, prior to transplantation, associated with pneumonitis. In vitro assessment of immune function demonstrated marked peripheral T cell depletion and loss of in vitro responsiveness to mitogen and allogeneic stimulation following FTLI. The administration of donor bone marrow at the time of transplantation did not produce chimerism. The results suggest that when properly utilized FTLI can produce effective adjunctive immunosuppression for clinical transplantation
Release fraction of PWR after severe accidents. Vol. 4
Energy Technology Data Exchange (ETDEWEB)
Aziz, M; El-Messeiry, A M [National Center for Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo (Egypt)
1996-03-01
Fission fragments and gases are emitted after accidents as a result of core meltdown and core concrete interactions. These aerosols are transported and fill the reactor containment. With increasing the pressure above pressure design bases, a failure of containment may occur and subsequently these aerosols will release into the external environment leading to a source term of radioactivity that affects the safety of workers and public. The amount of aerosol which escapes to the environment can be described by the release fraction which is defined as the total accumulated aerosol which initially enters the containment. The factors that affect the release fraction is studied, and the aerosol dynamics equation is used to model the release of aerosol to the outside atmosphere. These factors are containment pressure, failure time,break area, the size of aerosol particle. It found that early failure time and higher pressure increase the release fraction, also the release faction is affected by the area and the aerosol particle size. 7 figs., 2 tabs.
Release fraction of PWR after severe accidents. Vol. 4
International Nuclear Information System (INIS)
Aziz, M.; El-Messeiry, A.M.
1996-01-01
Fission fragments and gases are emitted after accidents as a result of core meltdown and core concrete interactions. These aerosols are transported and fill the reactor containment. With increasing the pressure above pressure design bases, a failure of containment may occur and subsequently these aerosols will release into the external environment leading to a source term of radioactivity that affects the safety of workers and public. The amount of aerosol which escapes to the environment can be described by the release fraction which is defined as the total accumulated aerosol which initially enters the containment. The factors that affect the release fraction is studied, and the aerosol dynamics equation is used to model the release of aerosol to the outside atmosphere. These factors are containment pressure, failure time,break area, the size of aerosol particle. It found that early failure time and higher pressure increase the release fraction, also the release faction is affected by the area and the aerosol particle size. 7 figs., 2 tabs
Technology of hardening fills for mined spaces
International Nuclear Information System (INIS)
Simek, P.; Holas, M.; Chyla, A.; Pech, P.
1985-01-01
The technology is described of hardening fills for mined spaces of uranium deposits in North Bohemian chalk. A special equipment was developed for the controlled preparation of a hardening mixture. The composition of the fill is determined by the strength of the filled rock, expecially by the standard strength, i.e., the minimal strength of the filling under uniaxial pressure. The said parameter determines the consumption of binding materials and thereby the total costs of the filling. A description is presented of the filling technology, including rabbit tube transport of the mixture and quality control. (Pu)
International Nuclear Information System (INIS)
Tanaka, Kenya; Namiki, Takahiro; Saito, Takashi; Tatsuoka, Sho; Imamura, Atsushi; Kuwahara, Keitaro; Aoki, Yuji; Sato, Hideyuki
2009-01-01
We have succeeded in growing Pr x Os 4 Sb 12 single crystals under ∼4GPa with high Pr-site filling fraction x. The electrical resistance measurements clearly show that the superconducting (SC) transition is sharper and the onset temperatures is lower in the single crystal samples grown under high pressure compared to that of the sample grown under ambient pressure. These results suggest that the double SC transition ascribed to sample inhomogeneity is suppressed in the sample grown under high pressure. The change of 4f-electron crystalline electric field energy splitting between the Γ 1 ground state and the Γ 4 (2) first excited state in the sample made under high pressure is proposed as one of the possible origins of the suppression of the double SC transition.
International Nuclear Information System (INIS)
Maftei, Constantin-Alin; Bayer, Christine; Shi, Kuangyu; Astner, Sabrina T.; Vaupel, Peter
2011-01-01
Background and purpose: Evaluate changes in total hypoxia and hypoxia subtypes in vital tumor tissue of human head and neck squamous cell carcinomas (hHNSCC) upon fractionated irradiation. Materials and methods: Xenograft tumors were generated from 5 hHNSCC cell lines (UT-SCC-15, FaDu, SAS, UT-SCC-5 and UT-SCC-14). Hypoxia subtypes were quantified in cryosections based on (immuno-)fluorescent marker distribution patterns of Hoechst 33342 (perfusion), pimonidazole (hypoxia) and CD31 (endothelium) in microcirculatory supply units (MCSUs). Tumors were irradiated with 5 or 10 fractions of 2 Gy, 5×/week. Results: Upon irradiation with 10 fractions, the overall fraction of hypoxic MCSUs decreased in UT-SCC-15, FaDu and SAS, remained the same in UT-SCC-5 and increased in UT-SCC-14. Decreases were observed in the proportion of chronically hypoxic MCSUs in UT-SCC-15, in the fraction of acutely hypoxic MCSUs in UT-SCC-15 and SAS, and in the percentage of hypoxemically hypoxic MCSUs in SAS tumors. After irradiation with 5 fractions, there were no significant changes in hypoxia subtypes. Changes in the overall fraction of hypoxic MCSUs were comparable to corresponding alterations in the proportions of acutely hypoxic MCSUs. There was no correlation between radiation resistance (TCD 50 ) and any of the investigated hypoxic fractions upon fractionated irradiation. Conclusions: This study shows that there are large alterations in the fractions of hypoxia subtypes upon irradiation that can differ from changes in the overall fraction of hypoxic MCSUs.
The effect of tube filling on the electronic properties of Fe filled carbon nanotubes
International Nuclear Information System (INIS)
Linganiso, Ella C.; Chimowa, George; Franklyn, Paul J.; Bhattacharyya, Somnath; Coville, Neil J.
2012-01-01
Graphical abstract: HRTEM image of a twisted CNT filled with a bent single crystal of Fe. Insets from top to bottom show the power spectra of the corresponding regions, indicating the twisting of the Fe lattice. Inset in the top right shows the relative angling of the lattice fringes to accommodate the twisting of the Fe. Highlights: ► Synthesis of Fe filled CNTs with Fe content varying from 3 to 35%. ► TEM analysis indicates that Fe in the tubes is in contact with the CNTs. ► TEM analysis reveals that α-Fe crystallizes after CNT formation. ► Temperature dependent electronic transport measurements performed. ► Conductivity varies with the % Fe filling in the CNTs. - Abstract: Carbon nanotubes filled with Fe nanostructures (Fe-CNTs) were synthesized using an injection method in a 1-stage horizontal CVD furnace and a bubbling method in a 2-stage horizontal CVD reactor. Fe-CNTs were obtained through the pyrolysis of a mixture of dichlorobenzene and ferrocene in 5%H 2 /Ar. Metal impurities from the Fe-CNTs were removed using 1 M HCl solution. CNTs filled with crystalline Fe nanoparticles, nanorods and nanowires were obtained using these procedures. An intimate interaction between the Fe and the CNT was established by HRTEM studies. The α-Fe phase was observed to be the most dominant fraction found in the synthesized Fe-CNTs. The Fe 2 O 3 residue obtained from the TGA analysis revealed the amount of Fe filled inside the CNTs and this ranged between 3 and 31% by mass after purification. The temperature dependence of the conductivity in the temperature range between 2.5 and 100 K for an entangled network of Fe-CNTs was measured. An increase in conductivity due to the increased Fe filling inside the CNTs with increased temperature was observed. The observed temperature dependence was explained in terms of variable range hopping (VRH) conduction mechanisms. A transition from Efros–Shklovskii behavior at low % Fe filling of the CNTs to Mott 3D VRH behavior at
International Nuclear Information System (INIS)
Passath, A.; Leb, G.
1985-01-01
A new equilibrium assay for the determination of serum free thyroxine was evaluated in 514 patients. The assay comprises a two-vial-procedure to measure total thyroxine and free thyroxine fraction by use of monoclonal antibodies. Free thyroxine concentrations are calculated from fT 4 -fraction and total thyroxine concentration readings. In euthyroidism the average free thyroxine fraction (%fT 4 ) was 0.011%, in hyperthyroidism this fraction was elevated, in hypothyroidism it was below normal. In patients with TBG anomalies, TBG values were inversely correlated with fT 4 fraction readings. The 'euthyroid reference range' of FT 4 (SPAC ET) was between 0.70 to 1.78ng/dl. This euthyroid range of FT 4 was determined from TT 4 concentrations measured by T 4 -RIA (SPAC T 4 MONO) which were 30% above TT 4 values measured by conventional T 4 -RIA (SPAC T 4 POLY; polyclonal antibodies). However, a different euthyroid range of FT 4 between 0.55 to 1.30 ng/dl was observed as well as by other investigators when conventional T 4 -RIA measurements were used for calculation of FT 4 values. Our results indicate that calculated FT 4 concentration values are highly dependent on the methods used for determination of total thyroxine concentrations. Precision and reproducability of this two vial equilibrium assay did not meet the requirements mandatory for the application as a clinical routine diagnostic procedure, and its general use for this purpose can as yet not be recommended. (Author)
International Nuclear Information System (INIS)
Trentham, D.E.; Belli, J.A.; Anderson, R.J.; Buckley, J.A.; Goetzl, E.J.; David, J.R.; Austen, K.F.
1981-01-01
Ten patients with refractory rheumatoid arthritis were given 3000 rad of fractionated total lymphoid irradiation in an uncontrolled therapeutic trial. Total lymphoid irradiation was associated with objective evidence of considerable clinical improvement in eight patients and with reduced blood lymphocyte counts in all 10. On completion of irradiation, there was an abrogation of lymphocyte reactivity in vitro in the patients with clinical responses, but abnormal antibody activities characteristic of rheumatoid arthritis and normal components of humoral immunity were not suppressed. Partial recrudescence of arthritis occurred shortly after a year after the completion of irradiation and was paralleled by a restitution of lymphocyte concentrations and responsiveness to mitogens to levels similar to those observed before irradiation. These data provide further evidence of T-cell involvement in the pathogenesis of rheumatoid arthritis and demonstrate that total lymphoid irradiation can induce temporary relief, but they do not ascertain whether the natural history of this disease was altered
International Nuclear Information System (INIS)
Trentham, D.E.; Belli, J.A.; Anderson, R.J.; Buckley, J.A.; Goetzl, E.J.; David, J.R.; Austen, K.F.
1981-01-01
Ten patients with refractory rheumatoid arthritis were given 3000 rad of fractionated total lymphoid irradiation in an uncontrolled therapeutic trial. Total lymphoid irradiation was associated with objective evidence of considerable clinical improvement in eight patients and with reduced blood lymphocyte counts in all 10. On completion of irradiation, there was an abrogation of lymphocyte reactivity in vitro in the patients with clinical responses, but abnormal antibody activities characteristic of rheumatoid arthritis and normal components of humoral immunity were not suppressed. Partial recrudescence of arthritis occurred shortly before a year after the completion of irradiation and was paralleled by a restitution of lymphocyte concentrations and responsiveness to mitogens to levels similar to those observed before irradiation. These data provide further evidence of T-cell involvement in the pathogenesis of rheumatoid arthritis and demonstrate that total lymphoid irradiation can induce temporary relief, but they do not ascertain whether the natural history of this disease was altered
Energy Technology Data Exchange (ETDEWEB)
Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M. [Institut Curie, 75 - Paris (France)
1998-05-01
The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who
Fractional laser-assisted drug delivery
DEFF Research Database (Denmark)
Erlendsson, Andrés M; Doukas, Apostolos G; Farinelli, William A
2016-01-01
BACKGROUND AND OBJECTIVE: Ablative fractional laser (AFXL) is rapidly evolving as one of the foremost techniques for cutaneous drug delivery. While AFXL has effectively improved topical drug-induced clearance rates of actinic keratosis, treatment of basal cell carcinomas (BCCs) has been challenging......, potentially due to insufficient drug uptake in deeper skin layers. This study sought to investigate a standardized method to actively fill laser-generated channels by altering pressure, vacuum, and pressure (PVP), enquiring its effect on (i) relative filling of individual laser channels; (ii) cutaneous...
The order and volume fill rates in inventory control systems
DEFF Research Database (Denmark)
Thorstenson, Anders; Larsen, Christian
2011-01-01
This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level m...
Directory of Open Access Journals (Sweden)
Eugenia BABILONI
2012-01-01
Full Text Available The fill rate is usually computed by using the traditional approach, which calculates it as the complement of the quotient between the expected unfulfilled demand and the expected demand per replenishment cycle, instead of directly the expected fraction of fulfilled demand. Furthermore the available methods to estimate the fill rate apply only under specific demand conditions. This paper shows the research gap regarding the estimation procedures to compute the fill rate and suggests: (i a new exact procedure to compute the traditional approximation for any discrete demand distribution; and (ii a new method to compute the fill rate directly as the fraction of fulfilled demand for any discrete demand distribution. Simulation results show that the latter methods outperform the traditional approach, which underestimates the simulated fill rate, over different demand patterns. This paper focuses on the traditional periodic review, base stock system when backlogged demands are allowed.
International Nuclear Information System (INIS)
Yamagishi, Takashi; Ozaki, Masaharu; Furutani, Yuhji; Yamamoto, Kouzo; Saeki, Atsushi; Satoh, Shinichi; Kusukawa, Reizo
1990-01-01
Contributions of rapid filling, slow filling and atrial systole to the left ventricular(LV) filling volume were analyzed with the use of radionuclide ventriculography at rest, both globally and regionally, in 34 patients with isolated disease of the left anterior descending coronary artery. The patients included 17 with a normal ejection fraction (EF≥50%; group 1) and 17 with a depressed EF (<50%; group 2), and the data were compared with those obtained from 13 normal subjects. A computer program subdivided the LV image into 4 regions, and time-activity curves were constructed globally and regionally by reverse-gating from the R wave. In both groups the contribution of rapid filling to the LV filling volume was decreased significantly in the affected septal and apical regions, and in the global left ventricle compared with that in normal subjects. In group 1, the contribution of atrial systole showed an increase in these affected regions and in the global left ventricle. In contrast, in group 2, the atrial contribution was not increased globally or regionally as much as was expected. However, the contribution of slow filling was either increased significantly or tended to increase in the affected regions and in the global left ventricle. There were negative correlations between the contribution of rapid filling and that of slow filling in the global left ventricle (r=-0.73, p<0.001) and in each of the septal, apical and lateral regions (r≥-0.60, p<0.001), which suggested that the contribution of slow filling as well as of atrial systole undergoes an increase as rapid filling is impaired. Thus, in patients with coronary artery disease, the left ventricle relies on slow filling as well as atrial systole to affect diastolic LV filling in the affected regions and in the global left ventricle in the presence of LV systolic dysfunction. (author)
The Quasi-Electron Shell Structure of the Fractional Quantum Hall Effect
Haxton, Wick; Haxton, Daniel
2015-04-01
The fractional quantum Hall effect (FQHE) formulated on a sphere resembles the nuclear shell model, with the desired translationally invariant states having total angular momentum zero. This property was exploited by Ginocchio and Haxton (GH) to derive a new set of scalar operators and a first-Landau-level representation of the full set of hierarchy states (fillings 1/3, 2/5, 3/7, etc.), with overlaps identical to those of Jain, who used unphysical higher Landau levels excitations followed by numerical projection. We demonstrate that the GH operators produce an appealing description of the FQHE as shells filled by non-interacting quasi-electrons, or composite fermions. These are explicitly constructed, and their planar forms are also found. The evolution of the shells and their quasi-electrons is quite unusual. The connections with electron correlations and Laughlin's variational arguments are described. We discuss how ``new states'' found experimentally at fillings such as 4/11 and 5/13 fit into this scheme. Work support in part by the US DOE Offices of Nuclear Physics and Basic Energy Sciences.
International Nuclear Information System (INIS)
Lee, Hae Gin; Lim, Gye Yeon; Yang, Il Kwon; Kim, Hack Hee; Lim, Jung Ik; Bahk, Yong Whee; Han, Sok Won; Han, Nam Ik; Lee, Young Sok
1991-01-01
Arterial fraction of total hepatic blood flow was estimated by a new method, slope method, on radionuclide angiogram using 99m Tc-DISIDA and was compared with that from 99m Tc-Phytate radionuclide angiogram. This study included 11 of normal subjects, 37 of intermediate group with various liver diseases, and 25 patients with liver cirrhosis. We analyzed the data with slope method from radionuclide angiograms and the results were compared with hepatic arterial fractions from uptake method, introduced by Lee et al. at 1986. The hepatic arterial fractions from radionuclide angiograms using 99m Tc-DISIDA and 99m Tc- Phytate were 0.32 ± 0.09 and 0.31 ± 0.11 respectively in normal subjects, and 0.75 ± 0.18 and 0.77 ± 0.21 respectively in patients with liver cirrhosis. The hepatic arterial fractions by the slope method was well correlated with those of the uptake method on 99m Tc-DISIDA scan. There was high correlation between the hepatic arterial fractions from 99m Tc-DISIDA and 99m Tc-Phytate scans. Hepatic arterial fraction estimated by the slope method is a useful index for the diagnosis of liver cirrhosis and the evaluation of status of portal hypertension.
International Nuclear Information System (INIS)
Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.
1981-01-01
Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors
International Nuclear Information System (INIS)
Mansour, M.A.; Roushdy, H.M.; Mazhar, F.M.; Abu-Gabal, H.A.
1986-01-01
A total number of 180 mature rats (120 females and 60 males) weighing from 120-140 g were used to study the effect of two doses (2 and 4 Gy) whole-body gamma irradiation on the level of total protein and protein fractions in serum of pregnant rats during the period of organogenesis. It was found that the levels of total protein, albumin and gamma globulins significantly decreased according to the doses of exposure. The levels of alpha and beta globulins significantly increased more in the serum of rats exposed to 2 Gy than in rats exposed to 4 Gy. The level of A/G ratio significantly decreased more in the serum of rats exposed to 2Gy than in those exposed to 4 Gy
Directory of Open Access Journals (Sweden)
Orlov Alexey A.
2017-01-01
Full Text Available The article presents results of research filling gas centrifuge cascade by process gas fed into different stages. The modeling of filling cascade was done for nickel isotope separation. Analysis of the research results shows that nickel isotope concentrations of light and heavy fraction flows after filling cascade depend on feed stage number.
International Nuclear Information System (INIS)
Lichter, A.S.; Tracy, D.; Lam, W.C.; Order, S.E.
1980-01-01
Bone marrow transplantation (BMT) after total body irradiation (TBI) and cyclophosphamide is being employed increasingly in the therapy of end stage leukemia. Interstitial pneumonitis (IP) represents a major acute toxicity after allogeneic transplantation. A more rapid reconstitution of lymphoid organs and bone marrow post transplant may result in increased immune competence and hence fewer opportunistic pulmonary infections and IP. By delaying the infusion of marrow to 72 hr after TBI (1250 rad at 7.5 rad/min) instead of the customary 24 hr, we can demonstrate an increase in initial repopulation of thymus, spleen and bone marrow, with syngeneic transplants in Lewis rats. Interstitial pneumonitis may also be caused, in part, by the pulmonary toxicity of large single exposures of TBI. Clinical and laboratory data suggest that fractionated TBI may be less toxic to the lung. When fractionated TBI (625 rad x 2, 7.5 rad/min) is compared to single dose TBI (1250 rad, 7.5 rad/min), and increased initial repopulation of lymphoid organs is observed when fractionated therapy is employed. Delay in marrow infusion and fractionation of TBI exposure may have clinical advantages in patients who receive BMT
Energy Technology Data Exchange (ETDEWEB)
Adatepe, M.H.; Nichols, K.; Powell, O.M.; Isaacs, G.H.
1984-01-01
The authors determined the first third filling fraction (1/3 FF), the maximum filling rate (1/3 FR) and the mean filling rate (1/3 MFR) for the first third diastolic filling period of the left ventricle in patients with coronary artery disease (CAD), valvular heart disease (VHD), pericardial effusion (PE), cardiomyopathies (CM), chronic obstructive lung disease (COPD) and in 5 normals-all from resting gated equilibrium studies. Parameters are calculated from the third order Fourier fit to the LV volume curve and its derivative. 1/3 FF% = 1/3 diastolic count - end systolic count / 1/3 diastolic count x 100. Patients with CAD are divided into two groups: Group I with normal ejection fraction (EF) and wall motion (WM); Group II with abnormal EF and WM. Results are shown in the table. Abnormal filling parameters are found not only in CAD but in VHD, PE and CM. The authors conclude that the first third LV filling parameters are sensitive but non-specific indicators of filling abnormalities caused by diverse etiologic factors. Abnormal first third filling parameters may occur in the presence of a normal resting EF and WM in CAD.
Crystallization of sheared hard spheres at 64.5% volume fraction
Swinney, H. L.; Rietz, F.; Schroeter, M.; Radin, C.
2017-11-01
A classic experiment by G.D. Scott Nature 188, 908, 1960) showed that pouring balls into a rigid container filled the volume to an upper limit of 64% of the container volume, which is well below the 74% volume fraction filled by spheres in a hexagonal close packed (HCP) or face center cubic (FCC) lattice. Subsequent experiments have confirmed a ``random closed packed'' (RCP) fraction of about 64%. However, the physics of the RCP limit has remained a mystery. Our experiment on a cubical box filled with 49400 weakly sheared glass spheres reveals a first order phase transition from a disordered to an ordered state at a volume fraction of 64.5%. The ordered state consists of crystallites of mixed FCC and HCP symmetry that coexist with the amorphous bulk. The transition is initiated by homogeneous nucleation: in the shearing process small crystallites with about ten or fewer spheres dissolve, while larger crystallites grow. A movie illustrates the crystallization process. German Academic Exchange Service (DAAD), German Research Foundation (DFG), NSF DMS, and R.A. Welch Foundation.
Experimental study of strontium sorption on fissure filling material
Energy Technology Data Exchange (ETDEWEB)
Eriksen, T E; Cui, Daqing [Royal Institute of Technology, Stockholm (Sweden). Dept. of Chemistry
1994-12-01
We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs.
Experimental study of strontium sorption on fissure filling material
International Nuclear Information System (INIS)
Eriksen, T.E.; Cui, Daqing
1994-12-01
We have carried out a comparative study of sorption and desorption of strontium in groundwater on separated magnetic and size fractions of fissure filling material taken from natural fissures in granitic rock. Complete reversibility of the sorption process was demonstrated by identical Freundlich isotherms, isotopic exchangeability and pH dependence of the distribution coefficients Rd. The sorption was found to be strongly pH dependent in the range 3-11. The pH effect can be accommodated in the sorption model by considering the surface areas and surface charges of the minerals in the fissure filling material. 20 refs, 9 figs, 3 tabs
International Nuclear Information System (INIS)
Ohashi, K.; Gerson, M.C.; Khoury, J.C.; Fischer, E.A.; Smith, H.S.
1990-01-01
This paper evaluates left ventricular diastolic filling (LVDF) in patients with type I diabetes mellitus (DM) in order to identify increased risk for subsequent cardiac events. The authors obtained radionuclide ventriculograms in 54 patients with type I DM. Median follow-up for cardiac complications was 63 months. We assessed peak filling rate (PFR; in end diastolic volume [EDV] per second), first 1/2 filling fraction (1/2 FF), and first 1/2 filling fraction/R-R interval (1/2 FF/R-R) by analysis of convariance to account for effects of age and R-R interval. Cardiac complications ere found in 15 of 54 patients
Energy Technology Data Exchange (ETDEWEB)
Schmitz, N; Goedde-Salz, E; Loeffler, H [Christian-Albrechts-Univ., Kiel (Germany, F.R.)
1985-06-01
Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process.
International Nuclear Information System (INIS)
Schmitz, N.; Goedde-Salz, E.; Loeffler, H.
1985-01-01
Cytogenetic findings from the bone marrow (BM) and the peripheral blood (PB) of nine consecutive patients after allogeneic bone marrow transplantation (BMT) for acute or chronic myelogenous leukaemia are reported. After a conditioning regimen consisting of cyclophosphamide and fractionated total body irradiation (TBI) given in five or six fractions of 2 Gy, persistence of host cells was detected in four out of seven cases with permanent engraftment. While one of these patients relapsed 4 months after host cells had been found in BM and PB, the other patients stayed relapse-free 124, 257 and 347 d after grafting. Before transplantation, the leukaemic cells in all three cases carried unique cytogenetic abnormalities giving the opportunity to distinguish the leukaemic population from chromosomally non-aberrant cells thought to represent residual normal host cells. As the persisting host cells after BMT lacked any cytogenetic abnormalities, it is suggested that they were members of residual normal clones not involved in the leukaemic process. (author)
COMMERCIAL SNF ACCIDENT RELEASE FRACTIONS
Energy Technology Data Exchange (ETDEWEB)
S.O. Bader
1999-10-18
The purpose of this design analysis is to specify and document the total and respirable fractions for radioactive materials that are released from an accident event at the Monitored Geologic Repository (MGR) involving commercial spent nuclear fuel (CSNF) in a dry environment. The total and respirable release fractions will be used to support the preclosure licensing basis for the MGR. The total release fraction is defined as the fraction of total CSNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. The radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses. This subset of the total release fraction is referred to as the respirable release fraction. Potential accidents may involve waste forms that are characterized as either bare (unconfined) fuel assemblies or confined fuel assemblies. The confined CSNF assemblies at the MGR are contained in shipping casks, canisters, or disposal containers (waste packages). In contrast to the bare fuel assemblies, the container that confines the fuel assemblies has the potential of providing an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. However, this analysis will not take credit for this additional bamer and will establish only the total release fractions for bare unconfined CSNF assemblies, which may however be
COMMERCIAL SNF ACCIDENT RELEASE FRACTIONS
International Nuclear Information System (INIS)
S.O. Bader
1999-01-01
The purpose of this design analysis is to specify and document the total and respirable fractions for radioactive materials that are released from an accident event at the Monitored Geologic Repository (MGR) involving commercial spent nuclear fuel (CSNF) in a dry environment. The total and respirable release fractions will be used to support the preclosure licensing basis for the MGR. The total release fraction is defined as the fraction of total CSNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. The radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses. This subset of the total release fraction is referred to as the respirable release fraction. Potential accidents may involve waste forms that are characterized as either bare (unconfined) fuel assemblies or confined fuel assemblies. The confined CSNF assemblies at the MGR are contained in shipping casks, canisters, or disposal containers (waste packages). In contrast to the bare fuel assemblies, the container that confines the fuel assemblies has the potential of providing an additional barrier for diminishing the total release fraction should the fuel rod cladding breach during an accident. However, this analysis will not take credit for this additional bamer and will establish only the total release fractions for bare unconfined CSNF assemblies, which may however be
Transport properties of partially-filled Ce{sub y}Co{sub 4}Sb{sub 12}
Energy Technology Data Exchange (ETDEWEB)
Uher, C; Chen, B; Hu, S; Morelli, D T; Meisner, G P
1997-07-01
The authors have investigated the magnetic and transport properties of Ce{sub y}Co{sub 4}Sb{sub 12} filled skutterudites with the filling fraction y {le} 0.1. These compounds are n-type materials that develop a magnetic moment upon the presence of trivalent cerium. Cerium has a strong influence on all transport properties and even in small amounts it drastically reduces the lattice thermal conductivity. The resulting figures of merit are comparable to the values established previously for the p-type filled skutterudites.
Direct comparison of fractional and integer quantized Hall resistance
Ahlers, Franz J.; Götz, Martin; Pierz, Klaus
2017-08-01
We present precision measurements of the fractional quantized Hall effect, where the quantized resistance {{R}≤ft[ 1/3 \\right]} in the fractional quantum Hall state at filling factor 1/3 was compared with a quantized resistance {{R}[2]} , represented by an integer quantum Hall state at filling factor 2. A cryogenic current comparator bridge capable of currents down to the nanoampere range was used to directly compare two resistance values of two GaAs-based devices located in two cryostats. A value of 1-(5.3 ± 6.3) 10-8 (95% confidence level) was obtained for the ratio ({{R}≤ft[ 1/3 \\right]}/6{{R}[2]} ). This constitutes the most precise comparison of integer resistance quantization (in terms of h/e 2) in single-particle systems and of fractional quantization in fractionally charged quasi-particle systems. While not relevant for practical metrology, such a test of the validity of the underlying physics is of significance in the context of the upcoming revision of the SI.
Commercial SNF Accident Release Fractions
Energy Technology Data Exchange (ETDEWEB)
J. Schulz
2004-11-05
The purpose of this analysis is to specify and document the total and respirable fractions for radioactive materials that could be potentially released from an accident at the repository involving commercial spent nuclear fuel (SNF) in a dry environment. The total and respirable release fractions are used to support the preclosure licensing basis for the repository. The total release fraction is defined as the fraction of total commercial SNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. Radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses; this subset of the total release fraction is referred to as the respirable release fraction. Accidents may involve waste forms characterized as: (1) bare unconfined intact fuel assemblies, (2) confined intact fuel assemblies, or (3) canistered failed commercial SNF. Confined intact commercial SNF assemblies at the repository are contained in shipping casks, canisters, or waste packages. Four categories of failed commercial SNF are identified: (1) mechanically and cladding-penetration damaged commercial SNF, (2) consolidated/reconstituted assemblies, (3) fuel rods, pieces, and debris, and (4) nonfuel components. It is assumed that failed commercial SNF is placed into waste packages with a mesh screen at each end (CRWMS M&O 1999). In contrast to bare unconfined fuel assemblies, the
Commercial SNF Accident Release Fractions
International Nuclear Information System (INIS)
Schulz, J.
2004-01-01
The purpose of this analysis is to specify and document the total and respirable fractions for radioactive materials that could be potentially released from an accident at the repository involving commercial spent nuclear fuel (SNF) in a dry environment. The total and respirable release fractions are used to support the preclosure licensing basis for the repository. The total release fraction is defined as the fraction of total commercial SNF assembly inventory, typically expressed as an activity inventory (e.g., curies), of a given radionuclide that is released to the environment from a waste form. Radionuclides are released from the inside of breached fuel rods (or pins) and from the detachment of radioactive material (crud) from the outside surfaces of fuel rods and other components of fuel assemblies. The total release fraction accounts for several mechanisms that tend to retain, retard, or diminish the amount of radionuclides that are available for transport to dose receptors or otherwise can be shown to reduce exposure of receptors to radiological releases. The total release fraction includes a fraction of airborne material that is respirable and could result in inhalation doses; this subset of the total release fraction is referred to as the respirable release fraction. Accidents may involve waste forms characterized as: (1) bare unconfined intact fuel assemblies, (2) confined intact fuel assemblies, or (3) canistered failed commercial SNF. Confined intact commercial SNF assemblies at the repository are contained in shipping casks, canisters, or waste packages. Four categories of failed commercial SNF are identified: (1) mechanically and cladding-penetration damaged commercial SNF, (2) consolidated/reconstituted assemblies, (3) fuel rods, pieces, and debris, and (4) nonfuel components. It is assumed that failed commercial SNF is placed into waste packages with a mesh screen at each end (CRWMS M andO 1999). In contrast to bare unconfined fuel assemblies, the
On minimal energy Hartree-Fock states for the 2DEG at fractional fillings
International Nuclear Information System (INIS)
Cabo Montes Oca, A. de.
1995-08-01
Approximate minimal energy solutions of the previously discussed general class of Hartree-Fock (HF) states of the 2DEG at 1/3 and 2/3 filling factors are determined. Their selfenergy spectrum is evaluated. Wannier states associated to the filled Bloch states are introduced in a lattice having three flux quanta per cell. They allow to rewrite approximately the ν = 1/3 HF Hamiltonian as sum of three independent tight-binding model Hamiltonians, one describing the dynamics in the band of occupied states and the other ones in the tow bands of excited states. The magnitude of the hopping integral indicates the enhanced role which should have the correlation energy in the present situation with respect to the case of the Yoshioka and Lee second order energy calculation for the lowest energy HF state. Finally, the discussion also suggests the Wannier function, which spreads an electron into a three quanta area, as a physical model for the composite fermion mean field one particle state. (author). 11 refs, 5 figs
International Nuclear Information System (INIS)
Delic, J.; Magdelenat, H.; Barbaroux, C.; Chaillet, M.-P.; Dubray, B.; Fourquet, A.; Cosset, J.-M.; Gluckman, E.; Girinsky, T.
1995-01-01
Ionizing radiations have been reported as an in vitro apoptosis initiating stimulus in human lymphocytes. As the cytotoxicity of ionizing radiations and chemotherapeutic agents appears to be dependent on the efficacy of cell death induction, the manipulation of apoptosis initiation might be used as a means to suppress some pathological process. In the present study the in vivo induction of γ-ray mediated programmed cell death in humans is reported. The in vivo induction of apoptosis in peripheral blood lymphocytes (PBL) by ionizing radiations was investigated in 33 patients after each of two sessions (2 Gy and 4 Gy) of fractionated total body irradiation (FTBI) as part of their conditioning regimen before bone marrow transplantation. PBL committed to apoptosis were scored before irradiation (S1), 4 h (S2) and 24 h after 2 Gy (S3, 14-17 h after the second 2 Gy fraction). Nuclear morphology and chromatin-DNA were analysed by fluorescence microscopy immediately after blood sample withdrawal (I) and after 24 h in cell culture medium (II). (author)
The order and volume fill rates in inventory control systems
DEFF Research Database (Denmark)
Thorstenson, Anders; Larsen, Christian
2011-01-01
This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total quantities the order fill rate would be the preferred service level...... measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...
Radiographic evaluation of root canal fillings accomplished by undergraduate dental students.
Yavari, Hamidreza; Samiei, Mohammad; Shahi, Shahriar; Borna, Zahra; Abdollahi, Amir Ardalan; Ghiasvand, Negar; Shariati, Gholamreza
2015-01-01
The purpose of this study was to evaluate the radiographic quality of root canal fillings by fourth-, fifth-, and sixth-year undergraduate students at Tabriz Faculty of Dentistry between 2006 and 2012. A total of 1183 root canal fillings in 620 teeth were evaluated by two investigators (and in case of disagreement by a third investigator) regarding the presence or absence of under-fillings, over-fillings and perforations. For each tooth, preoperative, working and postoperative radiographs were checked. The Pearson's chi-square test was used for statistical evaluation of the data. Inter-examiner agreement was measured by Cohen's kappa (k) values. The level of significance was set at 0.05. Total frequencies of over-filling, under-filling and perforation were 5.6%, 20.4% and 1.9%, respectively. There were significant differences between frequencies of over- and under-fillings (P<0.05). Unacceptable quality, under- and over-fillings were detected in 27.9% of 1183 evaluated canals. The technical quality of root canal therapies performed by undergraduate dental students using step-back preparation and lateral compaction techniques was unacceptable in almost one-fourth of the cases.
Second Study of Hyper-Fractionated Radiotherapy
Directory of Open Access Journals (Sweden)
R. Jacob
1999-01-01
Full Text Available Purpose and Method. Hyper-fractionated radiotherapy for treatment of soft tissue sarcomas is designed to deliver a higher total dose of radiation without an increase in late normal tissue damage. In a previous study at the Royal Marsden Hospital, a total dose of 75 Gy using twice daily 1.25 Gy fractions resulted in a higher incidence of late damage than conventional radiotherapy using 2 Gy daily fractions treating to a total of 60 Gy. The current trial therefore used a lower dose per fraction of 1.2 Gy and lower total dose of 72 Gy, with 60 fractions given over a period of 6 weeks.
Directory of Open Access Journals (Sweden)
O. Shalimova
2012-03-01
Full Text Available The character of changes in total protein fraction of muscle tissue of pork with PSE defects in the process of cooking at temperatures ranging from 40 to 72 g.C in steps of 2 g.C is investigated. Our studies have revealed differences in the change of state the total fraction of muscle proteins with defects PSE pork during cooking.
Intraventricular filling under increasing left ventricular wall stiffness and heart rates
Samaee, Milad; Lai, Hong Kuan; Schovanec, Joseph; Santhanakrishnan, Arvind; Nagueh, Sherif
2015-11-01
Heart failure with normal ejection fraction (HFNEF) is a clinical syndrome that is prevalent in over 50% of heart failure patients. HFNEF patients show increased left ventricle (LV) wall stiffness and clinical diagnosis is difficult using ejection fraction (EF) measurements. We hypothesized that filling vortex circulation strength would decrease with increasing LV stiffness irrespective of heart rate (HR). 2D PIV and hemodynamic measurements were acquired on LV physical models of varying wall stiffness under resting and exercise HRs. The LV models were comparatively tested in an in vitro flow circuit consisting of a two-element Windkessel model driven by a piston pump. The stiffer LV models were tested in comparison with the least stiff baseline model without changing pump amplitude, circuit compliance and resistance. Increasing stiffness at resting HR resulted in diminishing cardiac output without lowering EF below 50% as in HFNEF. Increasing HR to 110 bpm in addition to stiffness resulted in lowering EF to less than 50%. The circulation strength of the intraventricular filling vortex diminished with increasing stiffness and HR. The results suggest that filling vortex circulation strength could be potentially used as a surrogate measure of LV stiffness. This research was supported by the Oklahoma Center for Advancement of Science and Technology (HR14-022).
Fractionalization and Entrepreneurial Activities
Awaworyi Churchill, Sefa
2015-01-01
The vast majority of the literature on ethnicity and entrepreneurship focuses on the construct of ethnic entrepreneurship. However, very little is known about how ethnic heterogeneity affects entrepreneurship. This study attempts to fill the gap, and thus examines the effect of ethnic heterogeneity on entrepreneurial activities in a cross-section of 90 countries. Using indices of ethnic and linguistic fractionalization, we show that ethnic heterogeneity negatively influences entrepreneurship....
Rahimi, Alireza; Sepehr, Mohammad; Lariche, Milad Janghorban; Mesbah, Mohammad; Kasaeipoor, Abbas; Malekshah, Emad Hasani
2018-03-01
The lattice Boltzmann simulation of natural convection in H-shaped cavity filled with nanofluid is performed. The entropy generation analysis and heatline visualization are employed to analyze the considered problem comprehensively. The produced nanofluid is SiO2-TiO2/Water-EG (60:40) hybrid nanofluid, and the thermal conductivity and dynamic viscosity of used nanofluid are measured experimentally. To use the experimental data of thermal conductivity and dynamic viscosity, two sets of correlations based on temperature for six different solid volume fractions of 0.5, 1, 1.5, 2, 2.5 and 3 vol% are derived. The influences of different governing parameters such different aspect ratio, solid volume fractions of nanofluid and Rayleigh numbers on the fluid flow, temperature filed, average/local Nusselt number, total/local entropy generation and heatlines are presented.
Total variation regularization for a backward time-fractional diffusion problem
International Nuclear Information System (INIS)
Wang, Liyan; Liu, Jijun
2013-01-01
Consider a two-dimensional backward problem for a time-fractional diffusion process, which can be considered as image de-blurring where the blurring process is assumed to be slow diffusion. In order to avoid the over-smoothing effect for object image with edges and to construct a fast reconstruction scheme, the total variation regularizing term and the data residual error in the frequency domain are coupled to construct the cost functional. The well posedness of this optimization problem is studied. The minimizer is sought approximately using the iteration process for a series of optimization problems with Bregman distance as a penalty term. This iteration reconstruction scheme is essentially a new regularizing scheme with coupling parameter in the cost functional and the iteration stopping times as two regularizing parameters. We give the choice strategy for the regularizing parameters in terms of the noise level of measurement data, which yields the optimal error estimate on the iterative solution. The series optimization problems are solved by alternative iteration with explicit exact solution and therefore the amount of computation is much weakened. Numerical implementations are given to support our theoretical analysis on the convergence rate and to show the significant reconstruction improvements. (paper)
Left ventricular filling under elevated left atrial pressure
Gaddam, Manikantam; Samaee, Milad; Santhanakrishnan, Arvind
2017-11-01
Left atrial pressure (LAP) is elevated in diastolic dysfunction, where left ventricular (LV) filling is impaired due to increase in ventricular stiffness. The impact of increasing LAP and LV stiffness on intraventricular filling hemodynamics remains unclear. We conducted particle image velocimetry and hemodynamics measurements in a left heart simulator (LHS) under increasing LAP and LV stiffness at a heart rate of 70 bpm. The LHS consisted of a flexible-walled LV physical model fitted within a fluid-filled chamber. LV wall motion was generated by a piston pump that imparted pressure fluctuations in the chamber. Resistance and compliance elements in the flow loop were adjusted to obtain bulk physiological hemodynamics in the least stiff LV model. Two LV models of increasing stiffness were subsequently tested under unchanged loop settings. LAP was varied between 5-20 mm Hg for each LV model, by adjusting fluid level in a reservoir upstream of the LV. For constant LV stiffness, increasing LAP lowered cardiac output (CO), while ejection fraction (EF) and E/A ratio were increased. For constant LAP, increasing LV stiffness lowered CO and EF, and increased E/A ratio. The implications of these altered hemodynamics on intraventricular filling vortex characteristics will be presented.
International Nuclear Information System (INIS)
Hagenbeek, A.; Martens, A.C.M.
1981-01-01
The efficacy of various total body irradiation (TBI) regimens prior to bone marrow transplantation was evaluated in a rat model for acute myelocytic leukemia (Dq = 85.1 cGy gamma ; N = 3.7). Using high dose rate gamma-irradiation (115 cGy/min), fractionated TBI with large total daily doses (400 to 600 cGy), either given as acute doses or as split doses at 8 hr intervals, was most effective. Split doses (2 fractions per day) offered no additional advantage. At the most, a 4 log leukemic cell kill was induced. No lethal toxicity was observed. Nine-hundred cGy flash TBI had a similar anti-tumor effect, but with this regimen almost half of the rats died from radiation-induced toxicity (lungs and gastro-intestinal tract). The results are explained in terms of differences between normal and leukemic cells as regards (a) repair of sublethal damage; and (b) repopulation. Low dose rate continuous gamma-irradiation (0.26 cGy/min) with total doses ranging from 900 to 2000 cGy was also quite effective. Maximally a 4 log cell kill was obtained. With 2000 cGy, 50% of the rats died from the gastro-intestinal tract-syndrome. In addition to the major role played by chemotherapy, TBI is mainly of importance in sterilizing the various sanctuaries in the body which contain leukemic cells anatomically resistant to most cytostatic agents
Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi
2018-05-01
This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.
The intraventricular filling vortex under heightened aortic blood pressure
Nelsen, Nicholas; Gaddam, Manikantam; Santhanakrishnan, Arvind
2017-11-01
Hypertension, or high aortic blood pressure, can induce structural changes in the left ventricle (LV) such as concentric hypertrophy. Previous studies have identified that the intraventricular filling vortex serves as an effective means of blood transport during diastolic filling. However, a fundamental understanding of how hypertension affects this vortex is unavailable. This knowledge can be useful for improving diagnosis and treatment of related heart disease conditions, including hypertensive heart failure. In this experimental study, we hypothesized that the circulation of the filling vortex would diminish with increased aortic pressure. Using a LV physical model within a left heart simulator, we performed hemodynamic measurements to acquire pressure and volumetric inflow profiles and 2D particle image velocimetry to visualize the intraventricular flow fields. Peak aortic pressures of 120 mm Hg, 140 mm Hg, and 160 mm Hg were each tested at heart rates of 70, 100, and 110 beats per minute, under: 1) reduced ejection fraction (EF), and 2) constant EF. Our results indicate that peak vortex circulation is reduced under elevated aortic pressures. Hemodynamics and characteristics of the intraventricular filling vortex in all examined experimental cases will be presented.
129 Xe-NMR of carbon black filled elastomers
International Nuclear Information System (INIS)
Sperling-Ischinsky, K.; Veeman, W.S.
1999-01-01
It is shown that 129 Xe-NMR is a powerful tool to investigate carbon black and carbon black filled elastomers. For the carbon black material itself the 129 Xe chemical shift of xenon adsorbed at the surface of carbon black aggregates yields information about the relative average pore size of the carbon black aggregates. The experimental 129 Xe-NMR results of carbon black filled ethylene-propylene-diene (EPDM) can be explained when it is assumed that the xenon atoms in the bound EPDM fraction exchange rapidly on the NMR time scale between a state where they are adsorbed on the carbon black surface and a state in which they are absorbed in the EPDM layer. This would imply that the carbon black aggregates are not completely covered with EPDM chains. (author)
Liu, Yingyi
2017-09-08
Prior studies on fraction magnitude understanding focused mainly on students with relatively sufficient formal instruction on fractions whose fraction magnitude understanding is relatively mature. This study fills a research gap by investigating fraction magnitude understanding in the early stages of fraction instruction. It extends previous findings to children with limited and primary formal fraction instruction. Thirty-five fourth graders with limited fraction instruction and forty fourth graders with primary fraction instruction were recruited from a Chinese primary school. Children's fraction magnitude understanding was assessed with a fraction number line estimation task. Approximate number system (ANS) acuity was assessed with a dot discrimination task. Whole number knowledge was assessed with a whole number line estimation task. General reading and mathematics achievements were collected concurrently and 1 year later. In children with limited fraction instruction, fraction representation was linear and fraction magnitude understanding was concurrently related to both ANS and whole number knowledge. In children with primary fraction instruction, fraction magnitude understanding appeared to (marginally) significantly predict general mathematics achievement 1 year later. Fraction magnitude understanding emerged early during formal instruction of fractions. ANS and whole number knowledge were related to fraction magnitude understanding when children first began to learn about fractions in school. The predictive value of fraction magnitude understanding is likely constrained by its sophistication level. © 2017 The British Psychological Society.
Eugenia BABILONI; Ester GUIJARRO; Manuel CARDÓS; Sofía ESTELLÉS
2012-01-01
The fill rate is usually computed by using the traditional approach, which calculates it as the complement of the quotient between the expected unfulfilled demand and the expected demand per replenishment cycle, instead of directly the expected fraction of fulfilled demand. Furthermore the available methods to estimate the fill rate apply only under specific demand conditions. This paper shows the research gap regarding the estimation procedures to compute the fill rate and suggests: (i) a ne...
International Nuclear Information System (INIS)
Waer, M.; Ang, K.K.; van der Schueren, E.; Vandeputte, M.
1984-01-01
When BALB/c mice received 17 daily fractions of 2 Gy each of total lymphoid irradiation (TLI, total dose 34 Gy) and 30 x 10 6 C 57 B1 bone marrow cells (BM) on the day after the last fraction, stable bone marrow chimerism without signs of graft-vs-host disease (GVHD) was obtained in 84% of the animals. On the contrary, in BALB/c mice receiving only seven fractions of TLI (total dose 14 Gy), all bone marrow grafts were rejected. When the last two fractions of a 14-Gy TLI course were given without shielding the extra lymphatic tissues (combined total lymphoid + total body irradiation, TLBI), chimerism could be induced in 53% of the animals. When this 14-Gy TLBI schedule was used, it was even possible to administer four fractions per day (multiple fractions per day schedule, MFD), thus reducing the overall treatment time to 2 consecutive days. After this concentrated form of TLBI, chimerism was detected in 35% of the animals. As in the 34-Gy TLI schedule, graft-vs-host reaction could not be prevented in the 14-Gy TLBI schedule when spleen lymphocytes (10 x 10 6 ) were added to the BM inocolum. Leucopenia or suppression of the phytohaemagglutinin (PHA)-induced blastogenesis could not predict which schedule would result in a successful allogeneic bone marrow take. Suppressor cells of the mixed lymphocyte reaction, on the other hand, were only found in the spleen of BALB/c mice treated with the TLI or TLBI schedules, which also resulted in stable bone marrow chimerism
Assessment of heavy metal contamination of dust at some selected fuel filling stations in Accra
International Nuclear Information System (INIS)
Afrifa, C. G.
2011-07-01
Heavy metal contaminated dust particles of fuel filling stations can be re-suspended into the ambient air and serve as a source of atmospheric pollution since the fine particles are aerodynamic and have longer life time in ambient air. This can cause ill-health effect on the fuel attendants and residents within the neighbourhood especially infants and the aged who are more vulnerable. In spite of this, not much research has been done on heavy metal contamination of dust at fuel filling stations. In this study, 55 dust samples were collected from six fuel filling stations in the Ga-East district and Accra Metropolitan assembly, both in Accra, in order to assess the levels of contamination of heavy metals; their possible sources and the human health risk associated with them. The dust samples were divided into two parts with one part sieved into four fractions using metric mesh sizes 500 µm, 200µm, 100µm and 45 µm, and pulverised. Total concentrations of heavy metals (Si, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Zr and Pb) were determined in the dust samples using energy dispersive X-ray fluorescence analysis. The pollution indices; enrichment factors (EF), index of geoaccumulation (Igeo), contamination factor (CF) and pollution load index (PLI) were used to identify possible levels of pollution from anthropogenic sources. The possible sources of metals were also identified with principal component analysis. Noncancer effect of children and adults due to exposure to dust from these fuel filling stations were also estimated. For the three fuelling areas, the average concentrations of V, Cr, Ni and Cu exceeded the acceptable values in common soil in the <45 µm fraction. The average concentration of Zn however exceeded the acceptable value only at the mixed-fuel fuelling area whereas the average concentration of Pb was within the acceptable value for all three fuelling areas. The dust samples showed moderate to significant enrichments for V, Cu, Br
Ding, I-Kang
2009-08-27
In this paper, the pore filling of spiro-MeOTAD (2,2\\',7,7\\'-tetrakis-(N,N-di-p-methoxyphenylamine)9, 9\\'-spirobifluorene) in mesoporous TiO2 films is quantified for the first time using XPS depth profiling and UVVis absorption spectroscopy. We show that spiro-OMeTAD can penetrate the entire depth of the film, and its concentration is constant throughout the film. We determine that in a 2.5-•m-thick film, the volume of the pores is 60-65% filled. The pores become less filled when thicker films are used. Such filling fraction is much higher than the solution concentration because the excess solution on top of the film can act as a reservoir during the spin coating process. Lastly, we demonstrate that by using a lower spin coating speed and higher spiro-OMeTAD solution concentration, we can increase the filling fraction and consequently the efficiency of the device
Effective-field-theory model for the fractional quantum Hall effect
International Nuclear Information System (INIS)
Zhang, S.C.; Hansson, T.H.; Kivelson, S.
1989-01-01
Starting directly from the microscopic Hamiltonian, we derive a field-theory model for the fractional quantum hall effect. By considering an approximate coarse-grained version of the same model, we construct a Landau-Ginzburg theory similar to that of Girvin. The partition function of the model exhibits cusps as a function of density and the Hall conductance is quantized at filling factors ν = (2k-1)/sup -1/ with k an arbitrary integer. At these fractions the ground state is incompressible, and the quasiparticles and quasiholes have fractional charge and obey fractional statistics. Finally, we show that the collective density fluctuations are massive
International Nuclear Information System (INIS)
Xie Lei; Ziegmann, Gerhard
2011-01-01
Research highlights: → PP/CNFs and PP/TiO 2 composites with relative high loading fractions (10, 20, 30 and 35 wt%) were fabricated by inner melt mixing process. Micro tensile test samples were formed by injection molding combined with variotherm process for all composites. → The morphological properties of all nano composites were characterized by WXRD, whose results imply the adding nano fillers did not change the crystal form of PP, but the crystallites size and distance between lattices of crystals were changed with various nano fillers and loading fractions. → DSC analysis show that due to the nucleating function of nano fillers, the peak temperature of crystallization was increased and the peak temperature of crystallization melting was decreased by adding the nanofillers. → The flow ability of nano composites was tested by high pressure single capillary rheometer and the results demonstrate that nano fillers increased the viscosity of PP matrix. → Based on these significant information and analysis foundation of the nano filled composites, the micro weld line samples were formed by injection molding process and characterized by tensile test method. From the achieved results, it can be found that in general, for functional nano filled polymer composites, the mechanical property of micro weld lines were obviously influenced by nano fillers' shape and loading fractions. → The E modulus of micro weld line was increased due to loading CNFs in PP matrix, while the elongation of the micro tensile samples with weld line is considerably decreased comparing with those of unfilled PP samples. The detrimental tensile strength of micro weld lines were observed when CNFs contents increasing, except for at a 10 wt%. → For TiO 2 nano particles filled PP, due to the poor dispersion of nano particles, at low loading fraction of 10 wt%, the E modulus and tensile strength of micro weld lines were decreased by filling nano particles, but when the loading fraction
Ding, I-Kang; Té treault, Nicolas; Brillet, Jé ré mie; Hardin, Brian E.; Smith, Eva H.; Rosenthal, Samuel J.; Sauvage, Fré dé ric; Grä tzel, Michael; McGehee, Michael D.
2009-01-01
In this paper, the pore filling of spiro-OMeTAD (2,2′,7,7′- tetrakis-(N,N-di-p-methoxyphenylamine)9,9′-spirobtfIuorene) in mesoporous TiO2 films is quantified for the first time using XPS depth profiling and UV-Vis absorption spectroscopy. It is shown that spiro-OMeTAD can penetrate the entire depth of the film, and its concentration is constant throughout the film. We determine that in a 2.5-μm-thick film, the volume of the pores is 60-65% filled. The pores become less filled when thicker films are used. Such filling fraction is much higher than the solution concentration because the excess solution on top of the film can act as a reservoir during the spin coating process. Lastly, we demonstrate that by using a lower spin coating speed and higher spiro-OMeTAD solution concentration, we can increase the filling fraction and consequently the efficiency of the device. © 2009 WILEY-VCH Verlag GmbH & Co. KGaA.
Ding, I-Kang
2009-08-10
In this paper, the pore filling of spiro-OMeTAD (2,2′,7,7′- tetrakis-(N,N-di-p-methoxyphenylamine)9,9′-spirobtfIuorene) in mesoporous TiO2 films is quantified for the first time using XPS depth profiling and UV-Vis absorption spectroscopy. It is shown that spiro-OMeTAD can penetrate the entire depth of the film, and its concentration is constant throughout the film. We determine that in a 2.5-μm-thick film, the volume of the pores is 60-65% filled. The pores become less filled when thicker films are used. Such filling fraction is much higher than the solution concentration because the excess solution on top of the film can act as a reservoir during the spin coating process. Lastly, we demonstrate that by using a lower spin coating speed and higher spiro-OMeTAD solution concentration, we can increase the filling fraction and consequently the efficiency of the device. © 2009 WILEY-VCH Verlag GmbH & Co. KGaA.
ADVANTAGES AND DISADVANTAGES OF THE SONICFILL™ METHOD FOR LATERAL FILLINGS
Directory of Open Access Journals (Sweden)
Nicolae BARANOV
2017-06-01
Full Text Available The aim of the study was to evaluate the advantages and disadvantages of bulk-fill type fillings realized with SONICFill™ over an 18 month interval, on a batch of patients with different ages and occupations. Materials and methods: the study was performed on a batch of 73 patients who addressed the Clinical of OdontologyEndodontics within the Platform of Practical Training (PIP of the Faculty of Dental Medicine of the ”Apollonia” University of Iaşi, between Octomber 1, 2014 - May 1, 2016, subjected to 91 bulk-fill fillings with SonicFill™ on the posterior teeth. Results and discussion: out of the total number of 73 patients, 56 came from the urban environment, and 17 - from the rural medium, the highest ratio being represented by the 21-30 year age group (45%, closely followed by the 31-40 year one (40%. As for gender distribution within the batch, nearly two-thirds are women, the rest being men. The education level influenced patients’ decision – that of accepting a new method of filling application. As to the types of teeth to which restorations were applied, the highest ratio is represented by lower molars (41%, followed by upper molars (23% and mandibular premolars (20%, the lowest number of restorations being applied to maxillary premolars. Out of the total number of 91 bulk-fill restorations, 28 were applied over a base filling while, in 63 restorations, the basic filling was absent. Conclusions: The SonicFill ™ system for bulk-fill posterior restorations has a number of advantages, such as: high photopolymerization depth, significant reduction of setting contraction, better composite adaptation to the cavity walls, long-term predictable clinical results.
Selection and specification criteria for fills for cut-and-fill mining
Energy Technology Data Exchange (ETDEWEB)
Thomas, E. G.
1980-05-15
Because of significant differences in placement and loading conditions, the ideal fill material for a cut-and-fill operation has different characteristics to those for a fill for a filled open stoping operation. The differing requirements of the two mining operations must be understood and accounted for in establishing fill selection and specification criteria. Within the paper, aspects of the particular requirements of cut-and-fill mining are analyzed and related to the specific fill tests and properties required. Emphasis is placed upon the role of fill in ground support, though this cannot be isolated from overall fill performance. Where appropriate, test data are introduced and areas requiring continuing research highlighted.
Semi solid metal processing: The fraction solid dilemma
International Nuclear Information System (INIS)
Nafisi, S.; Emadi, D.; Ghomashchi, R.
2009-01-01
One of the most challenging aspects in semi solid metal (SSM) processing is to determine the actual volume fraction of the solid at the processing temperature. The fraction has great impact on the SSM slurry viscosity and the subsequent filling of the mold in the casting stage. Three methods, namely quantitative metallography, thermodynamic calculation, and thermal analysis are employed to investigate and clarify the contradictory open literature reports about the real value of the volume fraction of primary particles. It is reported that the discrepancies between the results obtained by different methods are caused mainly by variations in cooling rates and by coarsening of the primaries during the quenching process
Semi solid metal processing: The fraction solid dilemma
Energy Technology Data Exchange (ETDEWEB)
Nafisi, S. [EVRAZ Inc. NA 100 Armour Road, Regina, SK, S4P 3C7 (Canada)], E-mail: Shahrooz.Nafisi@evrazincna.com; Emadi, D. [CEPG, CanmetENERGY, Natural Resources Canada, Ottawa, ON, K1A 1M1 (Canada); Ghomashchi, R. [Advanced Materials and Processing Research Institute, Suite 122, A7-1390 Major MacKenzie, ON, L4S 0A1 (Canada)
2009-05-15
One of the most challenging aspects in semi solid metal (SSM) processing is to determine the actual volume fraction of the solid at the processing temperature. The fraction has great impact on the SSM slurry viscosity and the subsequent filling of the mold in the casting stage. Three methods, namely quantitative metallography, thermodynamic calculation, and thermal analysis are employed to investigate and clarify the contradictory open literature reports about the real value of the volume fraction of primary particles. It is reported that the discrepancies between the results obtained by different methods are caused mainly by variations in cooling rates and by coarsening of the primaries during the quenching process.
Improving the support characteristics of hydraulic fill
Energy Technology Data Exchange (ETDEWEB)
Corson, D. R.; Dorman, K. R.; Sprute, R. H.
1980-05-15
Extensive laboratory and field testing has defined the physical properties of hydraulic fill. Effect of void ratio on percolation rate has been quantified, and tests were developed to estimate waterflow through fill material in a given state underground. Beneficial effect on fill's support capability through addition of cement alone or in conjunction with vibratory compaction has been investigated. Two separate field studies in operating cut-and-fill mines measured vein-wall deformation and loads imposed on backfilled stopes. Technology has been developed that will effectively and efficiently dewater and densify ultra-fine-grained slurries typical of metal mine hydraulic backfill. At least two operators are using this electrokinetic technique to dewater slimes collected in underground sumps or impoundments. This technique opens up the possibility of using the total unclassified tailings product as a hydraulic backfill. Theoretical enhancement of ground support and rock-burst control through improved support capability will be tested in a full-scale mine stope installation. Both a horizontal layer and a vertical column of high modulus fill will be placed in an attempt to reduce stope wall closure, support more ground pressure, and lessen rock-burst occurrence.
International Nuclear Information System (INIS)
Pearson, M.J.; Nelson, C.S.
2005-01-01
Carbonate concretion bodies, representing a number of morphological types, and associated calcite fracture fills, mainly from New Zealand, have been studied both organically and inorganically. Extracted organic material is dominated by a complex polymeric dark brown highly polar fraction with a subordinate less polar and lighter coloured lipid fraction. The relative proportion of the two fractions is the principal control on the colour of fracture fill calcites. Concretions are classified mainly by reference to their carbonate stable carbon and oxygen isotope and cation composition. Typical subspherical calcitic septarian concretions, such as those in the Paleocene Moeraki and the Eocene Rotowaro Siltstones, contain carbon derived mainly by bacterial sulfate reduction in marine strata during early diagenesis. Other concretions, including a septarian calcitic type from the Northland Allochthon, have a later diagenetic origin. Siderite concretions, abundant in the nonmarine Waikato Coal Measures, are typically dominated by methanogenic carbon, whereas paramoudra-like structures from the Taranaki Miocene have the most extreme carbon isotope compositions, probably resulting from methane formation or oxidation in fluid escape conduits. Lipids from concretion bodies and most fracture fill calcites contain significant concentrations of fatty acids. Concretion bodies dominated by bimodally distributed n-fatty acids with strong even-over-odd preference, in which long chain n-acids are of terrestrial origin, have very low hydrocarbon biomarker maturities. Concretion bodies that lack long chain n-acids often have higher apparent biomarker maturity and prominent alpha-omega diacids. Such diacids are abundant in fracture fill calcites at Rotowaro, especially where calcite infills the septaria of a siderite concretion in the non-marine Waikato Coal Measures, and support the view that fluid transport resulted in carbonate entrapment of the fracture-hosted acids. Diacids also
International Nuclear Information System (INIS)
Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.
1980-01-01
Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)
The order and volume fill rates in inventory control systems
DEFF Research Database (Denmark)
Thorstenson, Anders; Larsen, Christian
2014-01-01
This paper differentiates between an order (line) fill rate and a volume fill rate and specifies their performance for different inventory control systems. When the focus is on filling complete customer orders rather than total demanded quantity the order fill rate would be the preferred service...... level measure. The main result shows how the order and volume fill rates are related in magnitude. Earlier results derived for a single-item, single-stage, continuous review inventory system with backordering and constant lead times controlled by a base-stock policy are extended in different directions...... extensions consider more general inventory control review policies with backordering, as well as some relations between service measures. A particularly important result in the paper concerns an alternative service measure, the customer order fill rate, and shows how this measure always exceeds the other two...
Exact Fill Rates for (R, s, S) Inventory Control With Gamma Distributed Demand
Moors, J.J.A.; Strijbosch, L.W.G.
2001-01-01
For the familiar (R; s; S) inventory control system only approximate expressions exist for the fill rate, i.e. the fraction of demand that can be satisfied from stock.Best-known are the approximations derived from renewal theory by Tijms & Groenevelt (1984), holding under specific conditions; in
Theory of fractional quantum hall effect
International Nuclear Information System (INIS)
Kostadinov, I.Z.
1985-08-01
A theory of the Fractional Quantum Hall Effect is constructed based on magnetic flux fractionization, which lead to instability of the system against selfcompression. A theorem is proved stating that arbitrary potentials fail to lift a specific degeneracy of the Landau level. For the case of 1/3 fractional filling a model 3-particles interaction is constructed breaking the symmetry. The rigid 3-particles wave function plays the role of order parameter. In a BCS type of theory the gap in the single particles spectrum is produced by the 3-particles interaction. The mean field critical behaviour and critical parameters are determined as well as the Ginsburg-Landau equation coefficients. The Hall conductivity is calculated from the first principles and its temperature dependence is found. The simultaneous tunnelling of 3,5,7 etc. electrons and quantum interference effects are predicted. (author)
International Nuclear Information System (INIS)
Schulman, D.S.; Biondi, J.W.; Matthay, R.A.; Zaret, B.L.; Soufer, R.
1989-01-01
Using a combined hemodynamic and radionuclide technique, 20 patients with varied ventricular function were evaluated during positive end-expiratory pressure (PEEP) application. Left ventricular (LV) and right ventricular (RV) ejection fractions and cardiac output were measured, and ventricular volumes were derived. Seven patients (group 1) who had an increase in LV end-diastolic volume with PEEP and 13 patients (group 2) who had the more typical response, a decrease in LV end-diastolic volume with PEEP, were identified. Compared with group 2, group 1 patients had a higher incidence of coronary artery disease (5 of 7 vs 1 of 13, p less than 0.005) and lower cardiac output (3.9 +/- 1.6 vs 9.1 +/- 3.2 liters/min, p less than 0.005), LV ejection fraction (27 +/- 13 vs 51 +/- 21%, p less than 0.05), RV ejection fraction (15 +/- 6 vs 32 +/- 8%, p less than 0.005) and peak filling rate (1.32 +/- 0.43 vs 3.51 +/- 1.70 end-diastolic volumes/s, p less than 0.05). LV and RV volumes increased and peak filling rate decreased with PEEP in group 1, whereas in group 2 LV volume decreased and RV volume and peak filling rate remained unchanged. Using stepwise regression analysis, the change in LV volume with PEEP was related directly to baseline systemic vascular resistance and inversely to baseline blood pressure. Similarly, the change in peak filling rate with PEEP was inversely related to the change in RV end-diastolic volume. Thus, the hemodynamic response to PEEP is heterogeneous and may be related to LV ischemia
International Nuclear Information System (INIS)
Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias
2008-01-01
To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R 2 = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R 2 = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology
2008-12-15
To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R{sup 2} = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R{sup 2} = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)
Directory of Open Access Journals (Sweden)
Michael J. Olsen
2015-09-01
Full Text Available Monitoring unstable slopes with terrestrial laser scanning (TLS has been proven effective. However, end users still struggle immensely with the efficient processing, analysis, and interpretation of the massive and complex TLS datasets. Two recent advances described in this paper now improve the ability to work with TLS data acquired on steep slopes. The first is the improved processing of TLS data to model complex topography and fill holes. This processing step results in a continuous topographic surface model that seamlessly characterizes the rock and soil surface. The second is an advance in the automated interpretation of the surface model in such a way that a magnitude and frequency relationship of rockfall events can be quantified, which can be used to assess maintenance strategies and forecast costs. The approach is applied to unstable highway slopes in the state of Alaska, U.S.A. to evaluate its effectiveness. Further, the influence of the selected model resolution and degree of hole filling on the derived slope metrics were analyzed. In general, model resolution plays a pivotal role in the ability to detect smaller rockfall events when developing magnitude-frequency relationships. The total volume estimates are also influenced by model resolution, but were comparatively less sensitive. In contrast, hole filling had a noticeable effect on magnitude-frequency relationships but to a lesser extent than modeling resolution. However, hole filling yielded a modest increase in overall volumetric quantity estimates. Optimal analysis results occur when appropriately balancing high modeling resolution with an appropriate level of hole filling.
International Nuclear Information System (INIS)
Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.
1981-01-01
Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI
Charge density wave crossover at low fillings in the fractional quantum Hall regime
International Nuclear Information System (INIS)
Cabo, A.; Claro, F.; Perez, A.; Maze, J.
2006-08-01
We show that besides the Wigner Crystal, the lowest Landau level supports a state with the same crystalline symmetry but qualitatively different charge density distribution at low densities. Instead of periodic peaks the new state forms percolating ridges that may favor an energy decrease through correlated ring exchange contributions. For the case of half electron per cell a crossover is found close to filling 1/7 between this new state and the Wigner-like solid, showing that transitions may occur from one to the other as the electron density is varied. This result is consistent with recent experimental findings. (author)
Impact of detector-element active-area shape and fill factor on super-resolution
Directory of Open Access Journals (Sweden)
Russell Craig Hardie
2015-05-01
Full Text Available In many undersampled imaging systems, spatial integration from the individual detector elements is the dominant component of the system point spread function (PSF. Conventional focal plane arrays (FPAs utilize square detector elements with a nearly 100% fill factor, where fill factor is defined as the fraction of the detector element area that is active in light detection. A large fill factor is generally considered to be desirable because more photons are collected for a given pitch, and this leads to a higher signal-to-noise-ratio (SNR. However, the large active area works against super-resolution (SR image restoration by acting as an additional low pass filter in the overall PSF when modeled on the SR sampling grid. A high fill factor also tends to increase blurring from pixel cross-talk. In this paper, we study the impact of FPA detector-element shape and fill factor on SR. A detailed modulation transfer function analysis is provided along with a number of experimental results with both simulated data and real data acquired with a midwave infrared (MWIR imaging system. We demonstrate the potential advantage of low fill factor detector elements when combined with SR image restoration. Our results suggest that low fill factor circular detector elements may be the best choice. New video results are presented using robust adaptive Wiener filter SR processing applied to data from a commercial MWIR imaging system with both high and low detector element fill factors.
Energy Technology Data Exchange (ETDEWEB)
Stelljes, T.S.; Looe, H.K.; Poppe, B. [Clinic for Radiation Therapy, Pius-Hospital, Oldenburg, DE (United States); WG Medical Radiation Physics, Carl von Ossietzky University, Oldenburg, DE (United States); Harder, D. [Prof. em., Medical Physics and Biophysics, Georg August University, Goettingen, DE (Germany)
2015-06-15
Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al.{sup 1} the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detector cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm{sup 2} for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References:{sup 1}A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)
International Nuclear Information System (INIS)
Stelljes, T.S.; Looe, H.K.; Poppe, B.; Harder, D.
2015-01-01
Purpose: To present a general definition of the fill factor realistically characterizing the “field coverage”, i.e. the MLC misalignment detection capabilities of a detector array. Methods: According to Gago-Arias et al. 1 the fill factor of a 2D array is defined as the ratio of the area enclosed by the FWHM of the fluence response function KM(x) of a single detector and its cell area defined by the detector spacing. More generally - accounting also for the possible overlap between FWHM’s of neighboured detectors - the fill factor is here defined as that fraction of the sum of the detector cell areas in which a defined MLC misalignment is detectable when the induced percentage signal changes exceed a detection threshold d. Ideally the generalized fill factor may reach 100 %. With user code EGS-chamber and a 2 MeV photon slit beam 0.25 mm wide, both types of the fill factor were calculated for an array with total cell area 100 cm 2 for chamber widths 1–9 mm, using =1mm, d=5%. Results: For single chamber width 5 mm, fill factors were 0.49 (FWHM) and 0.61 (generalized). For chamber width 2 mm the FWHM fill factor was 0.13 whereas the generalized fill factor was 0.32. For chamber widths above 7 mm, the FWHM fill factor exceeds unity, and the general fill factor is exactly 1.00. Conclusions: An updated fill factor definition is introduced which, as a generalization of the FWHM-based definition, more closely estimates the performance of small array chambers and gives a realistic value in the case of overlapping sensitive areas of neighboured chambers. References: 1 A. Gago-Arias, L. Brualla-Gonzalez, D.M. Gonzalez-Castano, F. Gomez, M.S. Garcia, V.L. Vega, J.M. Sueiro, J. Pardo-Montero, “Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays,” Phys. Med. Biol. 57, 2005–2020 (2012)
Saha, Subrata; Musib, Mrinal
2011-01-01
Reactions of bone cells to orthopedic wear debris produced by the articulating motion of total joint replacements (TJRs) are largely responsible for the long-term failure of such replacements. Metal and polyethylene (PE) wear particles isolated from fluids from total joint simulators, as well as particles that are fabricated by other methods, are widely used to study such in vitro cellular response. Prior investigations have revealed that cellular response to wear debris depends on the size, shape, and dose of the particles. Hence, to have a better understanding of the wear-mediated osteolytic process it is important that these particles are well characterized and clinically relevant, both qualitatively, and quantitatively. In this study we have fractionated both ultra-high molecular weight polyethylene (UHMWPE) and Ti particles, into micron (1.0-10.0 μm), submicron (0.2-1.0 μm), and nanoparticle (0.01-0.2 μm) fractions, and characterized them based on the following size-shape descriptors as put forth in ASTM F1877: i) equivalent circle diameter (ECD), ii) aspect ratio (AR), iii) elongation (E), iv) roundness (R), and v) form factor (FF). The mean (± SD) ECDs (in μm) for micron, submicron, and nanoparticles of UHMWPE were 1.652 ± 0.553, 0.270 ± 0.180, and 0.061 ± 0.035, respectively, and for Ti were 1.894 ± 0.667, 0.278 ± 0.180, and 0.055 ± 0.029, respectively. The values for other descriptors were similar (no statistically significant difference). The nanofraction particles were found to be more sphere-like (higher R and FF values, and lower E and AR values) as compared to larger particles. Future experiments will involve use of these well characterized particles for in vitro studies.
Ding, Linlin; Wang, Yanji; Wu, Zhaoliang; Liu, Wei; Li, Rui; Wang, Yanyan
2016-10-02
A novel technology coupling extraction and foam fractionation was developed for separating the total saponins from Achyranthes bidentata. In the developed technology, the powder of A. bidentata was loaded in a nylon filter cloth pocket with bore diameter of 180 µm. The pocket was fixed in the bulk liquid phase for continuously releasing saponins. Under the optimal conditions, the concentration and the extraction rate of the total saponins in the foamate by the developed technology were 73.5% and 416.2% higher than those by the traditional technology, respectively. The foamates obtained by the traditional technology and the developed technology were analyzed by ultraperformance liquid chromatography-mass spectrometry to determine their ingredients, and the results appeared that the developed technology exhibited a better performance for separating saponins than the traditional technology. The study is expected to develop a novel technology for cost effectively separating plant-derived materials with surface activity.
Simulation of mould filling process for composite skeleton castings
Directory of Open Access Journals (Sweden)
M. Dziuba
2008-04-01
Full Text Available In this work authors showed selected results of simulation and experimental studies on temperature distribution during solidification of skeleton casting and mould filling process. The aim of conducted simulations was the choice of thermal and geometrical parameters for the needs of designed calculations of the skeleton castings and the estimation of the guidelines for the technology of manufacturing. The subject of numerical simulation was the analysis of ability of filling the channels of core by liquid metal at estability technological parameters.. Below the assumptions and results of the initial simulated calculations are presented. The total number of the nodes in the casting was 1920 and of the connectors was 5280 what gave filling of 100% for the nodes and 99,56% for the connectors in the results of the simulation. Together it resulted as 99,78 % of filling the volume of the casting. The nodes and connectors were filled up to the 30 level of the casting in the simulation. The all connectors were filled up to the 25 level of the casting in the simulation. Starting from the 25 level individual connectors at the side surface of the casting weren’t filled up. The connectors weren’t supplied by multi-level getting system. The differences of filling the levels are little (maximally 5 per cent.
DEFF Research Database (Denmark)
Diederichsen, Axel Cosmus Pyndt; Møller, Jacob E; Thayssen, Per
2010-01-01
Abstract Objectives. We have previously shown that repeated intracoronary infusion of bone marrow cells (BMSC) did not improve left ventricular (LV) ejection fraction in patients with chronic ischemic heart failure. However, the impact of BMSC therapy on LV diastolic filling has remained uncertain....... Conclusion. In this non-randomised study repeated intracoronary BMSC infusions had a beneficial effect on LV filling in patients with chronic ischemic heart failure. Randomised studies are warranted....
Bulk fill restoratives: to cap or not to cap--that is the question?
Tomaszewska, Iwona M; Kearns, Jennifer O; Ilie, Nicoleta; Fleming, Garry J P
2015-03-01
To assess the cuspal deflection and cervical microleakage scores of standardised large mesio-occlusal-distal (MOD) cavities filled with different restoration protocols: (1) conventional resin restoratives, (2) bulk fill flowable base materials 'capped' with a conventional dimethacrylate resin-based composite (RBC) or (3) bulk fill resin restorative materials. Standardised MOD cavities were prepared in sixty-four sound maxillary premolar teeth and randomly allocated to eight groups. Restorations were placed in conjunction with a universal bonding system and resin restorative materials were irradiated with a quartz-tungsten-halogen light-curing-unit. Restoration protocol (eight oblique increments of conventional resin restorative, bulk fill flowable base and two occlusal 'capping' RBC increments (three increments in total) or bulk fill resin restorative (two increments)) was the dependent variable. A twin channel deflection measuring gauge measured the buccal and palatal cuspal deflections. Teeth were thermally fatigued, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. Post hoc Tukey's tests highlighted significant differences in the mean total cuspal deflection values between resin restoratives (p fill flowable base materials with occlusal 'capping' RBC increments (restoration protocol 2) compared with bulk fill resin restoratives (restoration protocol 3). Not all bulk fill flowable materials or bulk fill resin restoratives behave in a similar fashion when used to restore standardised MOD cavities in maxillary premolar teeth and material selection is vital in the absence of clinical data. Poorly performing bulk fill flowable materials or bulk fill restoratives can be identified using the cuspal deflection and cervical microleakage protocol which could save the complications encountered clinically when restoring Class II restorations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Intestinal complications following accelerated fractionated X-irradiation
International Nuclear Information System (INIS)
Hauer-Jensen, M.; Poulakos, L.; Osborne, J.W.
1990-01-01
Due to paucity of suitable animal models, it has been difficult to study the development of long-term intestinal complications following fractionated irradiation. We recently developed a model which allows multiple radiation exposures of a short segment of rat ileum without the need for repeated surgery. In the present series, this model was used to study the influence of shortening the total treatment time (accelerated fractionation) on development of radiation enteropathy. Male rats were orchiectomized and a short segment of distal ileum was transposed to the scrotum. Starting 3 weeks after surgery, the scrotum containing the intestinal segment was X-irradiated with 20 fractions of 2.8 Gy (total dose 56 Gy). Two fractionation schedules were compared: one fraction per day (total treatment time 26 days) and 3 fractions per day (total treatment time 7 days). Actuarial survival curves were obtained, and the degree of radiation injury was assessed 2, 8 and 26 weeks after the last radiation exposure using a semiquantitative histopathologic scoring system. There was no mortality from acute radiation injury in either treatment group. All animals of the 1-fraction/day group survived the observation period (26 weeks). In the 3-fraction/day group, there was significant mortality due to intestinal obstruction, and cumulative mortality at 26 weeks was 100%. Radiation injury, as assessed by the histopathologic scoring system, was also more pronounced in this group than in the 1-fraction/day group. We conclude that shortening the total treatment time significantly increases the severity of late intestinal complications. Our data are suggestive of an association between acute mucosal damage and chronic radiation injury of the small intestine. (orig.)
International Nuclear Information System (INIS)
Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette
2017-01-01
To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de
Directory of Open Access Journals (Sweden)
E. M. Nurullaev
2013-04-01
Full Text Available The computational method of optimum fractional composition of a dispersible filler of polymeric composite on the basis of three-dimensionally linked elastomer is developed according to non-linear programming. The coefficient of dynamic viscosity of polymeric suspension or the initial module of a viscoelasticity of the join solidification low-molecular rubbers with the final functional groups, filled by many fractional dioxide of silicon are considered as criteria of optimization. Influence of the limiting volume filling on energy of mechanical destruction was investigated. The elastomeric material is offered for use as a covering of asphalt highways in the form of a frost-proof waterproofing layer, which allowing multiply to increase operating properties.
Directory of Open Access Journals (Sweden)
Wojciech KOZERA
2013-03-01
Full Text Available Over 2003-2005 at the Experiment Station at Wierzchucinek at the University of Technology and Life Sciences in Bydgoszcz, there was performed a strict one-factor micro-plot experiment in split-splot design. The factor tested was a type of microelements [n=5: Cu, Zn, Mn, Mo, B]. The microelements were foliar sprayed in a chelated form, as the series of Symfonia fertilizers. The study aimed at comparing the effect of five agricultural-engineering basic microelements on the contents and protein composition of the seeds of Aura cultivar. The fertilization applied, boron and manganese in particular, showed an effect on the increase in the contents of total protein in bean seeds. It also modified the fractional composition of the bean seed protein. There was observed a clear increase in the fraction of albumins and globulins in seeds as a result of the microelements applied, except for boron. The fertilization with molybdenum, boron, copper and zinc reduced the content of glutelins, and the sum of glulelins and prolamines in the bean seeds.
INS gas-filled recoil isotope separator
International Nuclear Information System (INIS)
Miyatake, M.; Nomura, T.; Kawakami, H.
1986-09-01
The characteristics and performance of a small sized gas-filled recoil isotope separator recently made at INS are described. The total efficiency and the ΔBρ/Bρ values have been measured using low velocity 16 O, 40 Ar and 68 As ions and found to be 10 and 5 %, respectively. The Z-dependence of the mean charge is discussed. (author)
Fractionation of Pb and Cu in the fine fraction (landfill.
Kaczala, Fabio; Orupõld, Kaja; Augustsson, Anna; Burlakovs, Juris; Hogland, Marika; Bhatnagar, Amit; Hogland, William
2017-11-01
The fractionation of metals in the fine fraction (landfill was carried out to evaluate the metal (Pb and Cu) contents and their potential towards not only mobility but also possibilities of recovery/extraction. The fractionation followed the BCR (Community Bureau of Reference) sequential extraction, and the exchangeable (F1), reducible (F2), oxidizable (F3) and residual fractions were determined. The results showed that Pb was highly associated with the reducible (F2) and oxidizable (F3) fractions, suggesting the potential mobility of this metal mainly when in contact with oxygen, despite the low association with the exchangeable fraction (F1). Cu has also shown the potential for mobility when in contact with oxygen, since high associations with the oxidizable fraction (F3) were observed. On the other hand, the mobility of metals in excavated waste can be seen as beneficial considering the circular economy and recovery of such valuables back into the economy. To conclude, not only the total concentration of metals but also a better understanding of fractionation and in which form metals are bound is very important to bring information on how to manage the fine fraction from excavated waste both in terms of environmental impacts and also recovery of such valuables in the economy.
DEFF Research Database (Denmark)
Farvin Habebullah, Sabeena; Andersen, Lisa Lystbæk; Otte, Jeanette
2016-01-01
This study aimed to characterise peptide fractions (>5 kDa, 3–5 kDa and fractions were dominated by Ala, Gly, Glu and Ser. The total amino acid composition had high proportions of Lys, Ala...... and Glu. The 3–5 kDa and fractions were further fractionated by size exclusion chromatography. All sub-fractions showed high Fe2+ chelating activity. The DPPH radical-scavenging activity of the 3–5 kDa fraction was exerted mainly by one sub-fraction dominated by peptides with masses below 600 Da....... The DPPH radical-scavenging activity of the fraction was exerted by sub-fractions with low molecular weight. The highest reducing power was found in a sub-fraction containing peptides rich in Arg, Tyr and Phe. Both free amino acids and low molecular weight peptides thus seemed to contribute...
DEFF Research Database (Denmark)
Larsen, Christian; Thorstenson, Anders
The order fill rate is less commonly used than the volume fill rate (most often just denoted fill rate) as a performance measure for inventory control systems. However, in settings where the focus is on filling customer orders rather than total quantities, the order fill rate should be the prefer......The order fill rate is less commonly used than the volume fill rate (most often just denoted fill rate) as a performance measure for inventory control systems. However, in settings where the focus is on filling customer orders rather than total quantities, the order fill rate should...
Directory of Open Access Journals (Sweden)
Ken eKurosaki
2014-10-01
Full Text Available The high-temperature thermoelectric properties of thallium (Tl and potassium (K double-filled cobalt antimonide (CoSb3-based skutterudites with nominal compositions TlxK0.3Co4Sb12 (x = 0.1–0.3 were investigated. The filling fraction of Tl in CoSb3 was enhanced by co-filling with K, which resulted in all of the samples showing the filled-skutterudite single phase. Owing to the high filling ratio, the carrier concentration in the sample with x = 0.3 was as high as 4.3 × 1020 cm−3 at room temperature. Furthermore, quite low lattice thermal conductivity (as low as 0.9 W m−1 K−1 was obtained for the sample with x = 0.3, probably because of strong phonon scattering by the Tl and K co-rattling effect, which resulted in a maximum zT of around one at 773 K.
International Nuclear Information System (INIS)
Waer, M.; Ang, K.K.; Vandeputte, M.; Van der Schueren, E.
1982-01-01
Three groups of C 57 /BL/Ka mice received total lymphoid irradiation (TLI) in a total dose of 34 Gy in three different fractionation schedules. The tolerance of all different schedules was excellent. No difference in the peripheral white blood cell and lymphocyte counts nor the degree of immunosuppression as measured by phytohaemaglutinin or concanavalin A induced blastogenesis and mixed lymphocyte reaction were observed at the end of the treatment and up to 200 days. When bone marrow transplantation was performed one day after the end of each schedule, chimerism without signs of graft versus host disease was induced in all the groups. However, from the results in a limited number of animals it seems that concentrated schedules were less effective for chimerism induction. It has been demonstrated that it is possible to reduce drastically the overall treatment time for TLI before bone marrow transplantation. Further investigations are necessary in order to determine the optimal time-dose-fractionation factors and the different perameters involved in the transplantation
Dong, Yongkwan
2014-01-01
Partially Yb-filled Fe substituted polycrystalline p-type skutterudites with nominal compositions YbxCo2.5Fe1.5Sb 12, with varying filler concentrations x, were synthesized by reacting the constituent elements and subsequent solid state annealing, followed by densification by hot-pressing. The compositions and filling fractions were confirmed with a combination of Rietveld refinement and elemental analysis. Their thermoelectric properties were evaluated from 300 to 800 K. The Seebeck coefficients for the specimens increase with increasing temperature and plateau at around 750 K. The thermal conductivity decreases with increasing Yb filling fraction, and bipolar conduction becomes evident and increases at elevated temperatures. A maximum ZT value of 0.8 was obtained at 750 K for Yb 0.47Co2.6Fe1.4Sb12. The thermoelectric properties and potential for further optimization are discussed in light of our results. © 2013 Elsevier Inc.
Left atrial strain: a new parameter for assessment of left ventricular filling pressure.
Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio
2016-01-01
In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.
International Nuclear Information System (INIS)
Gerstein, Johanna; Meyer, Andreas; Fruehauf, Joerg; Karstens, Johann H.; Bremer, Michael; Sykora, Karl-Walter
2009-01-01
Purpose: to retrospectively assess the incidence and time course of renal dysfunction in children (≤ 16 years) following total-body irradiation (TBI) before allogeneic stem cell transplantation (SCT). Patients and methods: between 1986 and 2003, 92 children (median age, 11 years; range, 3-16 years) underwent TBI before allogeneic SCT. 43 of them had a minimum follow-up of 12 months (median, 51 months; range, 12-186 months) and were included into this analysis. Conditioning regimen included chemotherapy and fractionated TBI with 12 Gy (n = 26) or 11.1 Gy (n = 17). In one patient, renal dose was limited to 10 Gy by customized renal shielding due to known nephropathy prior to SCt. Renal dysfunction was defined as an increase of serum creatinine > 1.25 times the upper limit of age-dependent normal. Results: twelve children (28%) experienced an episode of renal dysfunction after a median of 2 months (range, 1-10 months) following SCT. In all but one patient renal dysfunction was transient and resolved after a median of 8 months (range, 3-16 months). One single patient developed persistent renal dysfunction with onset at 10 months after SCT. None of these patients required dialysis. The actuarial 3-year freedom from persistent renal toxicity for children surviving > 12 months after SCt was 97.3%. Conclusion: the incidence of persistent renal dysfunction after fractionated TBI with total doses ≤ 12 Gy was very low in this analysis. (orig.)
Noe, BD; Baste, CA; Bauer, GE
1977-01-01
Anglerfish islets were homogenized in 0.25 M sucrose and separated into seven separate subcellular fractions by differential and discontinuous density gradient centrifugation. The objective was to isolate microsomes and secretory granules in a highly purified state. The fractions were characterized by electron microscopy and chemical analyses. Each fraction was assayed for its content of protein, RNA, DNA, immunoreactive insulin (IRI), and immunoreactive glucagon (IRG). Ultrastructural examination showed that two of the seven subcellular fractions contain primarily mitochondria, and that two others consist almost exclusively of secretory granules. A fifth fraction contains rough and smooth microsomal vesicles. The remaining two fractions are the cell supernate and the nuclei and cell debris. The content of DNA and RNA in all fractions is consistent with the observed ultrastructure. More than 82 percent of the total cellular IRI and 89(percent) of the total cellular IRG are found in the fractions of secretory granules. The combined fractions of secretory granules and microsomes consistently yield >93 percent of the total IRG. These results indicate that the fractionation procedure employed yields fractions of microsomes and secretory granules that contain nearly all the immunoassayable insulin and glucagons found in whole islet tissue. These fractions are thus considered suitable for study of proinsulin and proglucagon biosynthesis and their metabolic conversion at the subcellular level. PMID:328517
Rakhimov, Abdulla; Askerzade, Iman N
2014-09-01
We have shown that the critical temperature of a Bose-Einstein condensate to a normal phase transition of noninteracting bosons in cubic optical lattices has a linear dependence on the filling factor, especially at large densities. The condensed fraction exhibits a linear power law dependence on temperature in contrast to the case of ideal homogeneous Bose gases.
Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin
2012-07-01
Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).
LENUS (Irish Health Repository)
Griffin, Alison
2012-02-01
INTRODUCTION: Normetanephrine and metanephrine are intermediate metabolites of noradrenaline and adrenaline metabolism. To assess whether normetanephrine and metanephrine analysis may aid in the diagnosis of Neuroblastoma, a reference interval for these metabolites must first be established. AIM: The overall aim of this study was to establish a paediatric age-related reference interval for the measurement of total fractionated metanephrines. METHODS: A total of 267 urine samples were analysed following acid hydrolysis. This releases the metanephrines from their sulphate-bound metabolites. The samples were analysed using reverse phase high-performance liquid chromatography with electro-chemical detection on a Gilson automated sequential trace enrichment of dialysate sample system. RESULTS: Data were analysed using Minitab Release version 14. Outliers were removed using the Dixon\\/Reed one-third rule. Partitioning of the age groups was achieved using Harris and Boyd\\'s standard normal deviate test. Non-parametric analysis of the data was performed, followed by the establishment of the 2.5th and the 97.5th reference limits. CONCLUSIONS: The established reference intervals are described in Table 2.
Fractionated irradiation and haematopoiesis. Pt. 3
International Nuclear Information System (INIS)
Ninkov, V.; Karanovic, D.; Savovski, K.
1982-01-01
The effect of total single fractionated irradiation with short time interval on heamatopoietic regeneration of the bone marrow and spleen was investigated. Also, the importance of first dose, when dose of 600 R was divided in two unequal fractions with time interval of 300 s was studied. The investigation was performed on 25 day old rats. The dose of 600 R (X-rays) was divided on: 500 + 100, 400 + 200, 300 + 300, 200 + 400 or 100 + 500 R with time interval of 150, 300 or 600 s. Ten days after irradiation the changes in blood, bone marrow and spleen were observed. After unequal fractionated dose with interval of 600 s slight effect was found. The results after intervals of 600 s and 300 s were significant, when the total dose was divided in two equal doses. The first dose has no promoting role in haematopoietic regeneration when total dose was unequally fractionated. (orig.) [de
International Nuclear Information System (INIS)
Cui, D.; Eriksen, T.
2000-01-01
The nucleation of a mineral crystal and its growth in groundwater carrying fractures 300 m above the Palmottu uranium deposit provide an impressive example of geochemical selectivity of uranium. Fracture-filling material was collected from a 3 mm thick fracture at depth 74.8-75 m (drillcore R348). SEM and EDS analyses on a thin section of the original fracture-filling show that the fracture filling is heterogeneous, composing mineral crystal particles and very porous clay-rich aggregates. The results of INAA on millimetre-sized single mineral crystals and aggregates selected from grinded fracture-filling show that porous aggregates (composed of clays and micrometer sized mineral particles) contain up to 1000 ppm U, which is higher than the average of the whole fracture-filling (400 ppm) and host rock related millimetre sized mineral particles (18-100 ppm). 233 U/ 238 U isotope exchange proves that a large fraction of the uranium in the fracture-filling is not easily exchanged with uranium in the solution. The amount of 238 U released in the isotope exchange experiment is too high to be explained by reversible U(VI) sorption. Oxidation state analyses show that 30% of the uranium exists as U(IV). Laboratory batch experiment at anoxic conditions proved that pyrite can immobilise U(VI). (orig.)
DEFF Research Database (Denmark)
Benetti, Ana Raquel; Havndrup-Pedersen, Cæcilie; Honoré, Daniel
2015-01-01
the restorative procedure. The aim of this study, therefore, was to compare the depth of cure, polymerization contraction, and gap formation in bulk-fill resin composites with those of a conventional resin composite. To achieve this, the depth of cure was assessed in accordance with the International Organization...... for Standardization 4049 standard, and the polymerization contraction was determined using the bonded-disc method. The gap formation was measured at the dentin margin of Class II cavities. Five bulk-fill resin composites were investigated: two high-viscosity (Tetric EvoCeram Bulk Fill, SonicFill) and three low......-viscosity (x-tra base, Venus Bulk Fill, SDR) materials. Compared with the conventional resin composite, the high-viscosity bulk-fill materials exhibited only a small increase (but significant for Tetric EvoCeram Bulk Fill) in depth of cure and polymerization contraction, whereas the low-viscosity bulk...
Energy Technology Data Exchange (ETDEWEB)
Gibbs, S.J.; Cassoni, A.M. [Middlesex Hospital, London (United Kingdom)
1996-11-01
The duration of the antiemetic effect of granisetron was examined in a pilot study of patients (n = 26) undergoing a standard emetogenic stimulus in the form of total body irradiation fractionated over 3-4 days, in a randomized comparison with twice-daily ondansetron. A single intravenous dose of granisetron at the onset of therapy was effective over the entire follow-up period in 50% (6/12) of patients, compared with 77% (10/13) prescribed twice-daily oral ondansetron for 3 or 4 days. The response rate within the first 24 hours from the start of irradiation was 67% (8/12) for granisetron and 77% (10/13) for ondansetron. Granisetron and ondansetron was therefore of similar efficacy within the first 24-hour period, but granisetron was less efficaceous more than 24 hours after the onset of therapy. Patients who required a second dose of granisetron did so at intervals of 12, 42, 47 and 48 hours following the first fraction of radiotherapy. The cost per patient in this study was 48 for granisetron and {sub 1}54 for ondanestron, but the dose scheduling we used cannot be recommended in view of the lower effectiveness of granisetron. (author).
International Nuclear Information System (INIS)
Gibbs, S.J.; Cassoni, A.M.
1996-01-01
The duration of the antiemetic effect of granisetron was examined in a pilot study of patients (n = 26) undergoing a standard emetogenic stimulus in the form of total body irradiation fractionated over 3-4 days, in a randomized comparison with twice-daily ondansetron. A single intravenous dose of granisetron at the onset of therapy was effective over the entire follow-up period in 50% (6/12) of patients, compared with 77% (10/13) prescribed twice-daily oral ondansetron for 3 or 4 days. The response rate within the first 24 hours from the start of irradiation was 67% (8/12) for granisetron and 77% (10/13) for ondansetron. Granisetron and ondansetron was therefore of similar efficacy within the first 24-hour period, but granisetron was less efficaceous more than 24 hours after the onset of therapy. Patients who required a second dose of granisetron did so at intervals of 12, 42, 47 and 48 hours following the first fraction of radiotherapy. The cost per patient in this study was 48 for granisetron and 1 54 for ondanestron, but the dose scheduling we used cannot be recommended in view of the lower effectiveness of granisetron. (author)
Time and angle resolved phonon absorption in the fractional quantum hall regime
International Nuclear Information System (INIS)
Devitt, A.M.
2000-09-01
The work described in this thesis is a study of the phonon absorption by a two-dimensional electron system (2DES) in the fractional quantum Hall regime and also at ν = 1/2. The fractional quantum Hall effect arises in 2DES's in high magnetic fields and is characterised by the quantisation of the transverse or Hall resistance and the vanishing longitudinal conductivity. The filling factor denotes the number of filled Landau levels and the quantum Hall effect occurs when this ratio is at certain rational odd denominator filling factors. The phenomenology of the effect arises due to the existence of an energy gap between the ground state and the lowest excited state. This energy gap is characterised by a deep minimum, or minima, at finite in-plane wavevector. Acoustic phonon absorption is expected to probe the energy gap at wavevectors close to or at the minimum in the dispersion curve. The experiments reported here incorporate the use of a thin film heater to produce a pulse of phonons of which a fraction are absorbed by the 2DES. A fast amplifier and signal averaging board enable detection of small signals due to absorption of phonons. The technique used allows time resolution of the phonon signal which typically takes place over a period of 10 μs or so. The time resolution enables different phonon modes to be studied. By altering the position of the heater relative to the 2DES angular resolution is also possible. The phonon absorption at several different filling factors has been investigated and the energy gaps found are in reasonable agreement with theoretical predictions. The absorption at ν 1/2 has also been investigated. Here the composite fermions are expected to have a well defined Fermi wavevector. The absorption at ν = 1/2 and the fractional quantum Hall states is found to be qualitatively and quantitatively different. We see that the change in electron temperature atν = 1/2 is much less than at ν = 1/3 due to the larger heat capacity. At ν = 1
30 CFR 817.72 - Disposal of excess spoil: Valley fill/head-of-hollow fills.
2010-07-01
... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.72 Disposal of excess spoil: Valley fill/head-of-hollow fills.... Uncontrolled surface drainage may not be directed over the outslope of the fill. (2) Runoff from areas above the fill and runoff from the surface of the fill shall be diverted into stabilized diversion channels...
Amato, Ernesto; Italiano, Antonio; Baldari, Sergio
2014-01-01
We developed a general model for the calculation of absorbed fractions in ellipsoidal volumes of soft tissue uniformly filled with alpha, beta and gamma emitting radionuclides. The approach exploited Monte Carlo simulations with the Geant4 code to determine absorbed fractions in ellipsoids characterized by a wide range of dimensions and ellipticities, for monoenergetic emissions of each radiation type. The so-obtained absorbed fractions were put in an analytical relationship with the 'general...
Impact of valley fills on streamside salamanders in southern West Virginia
Wood, Petra Bohall; Williams, Jennifer M.
2013-01-01
Valley fills associated with mountaintop-removal mining bury stream headwaters and affect water quality and ecological function of reaches below fills. We quantified relative abundance of streamside salamanders in southern West Virginia during 2002 in three streams below valley fills (VFS) and in three reference streams (RS). We surveyed 36 10- × 2-m stream transects, once in summer and fall, paired by order and structure. Of 2,343 salamanders captured, 66.7% were from RS. Total salamanders (adults plus larvae) were more abundant in RS than VFS for first-order and second-order reaches. Adult salamanders had greater abundance in first-order reaches of RS than VFS. Larval salamanders were more abundant in second-order reaches of RS than VFS. No stream width or mesohabitat variables differed between VFS and RS. Only two cover variables differed. Silt cover, greater in VFS than RS first-order reaches, is a likely contributor to reduced abundance of salamanders in VFS. Second-order RS had more boulder cover than second-order VFS, which may have contributed to the higher total and larval salamander abundance in RS. Water chemistry assessments of our VFS and RS reported elevated levels of metal and ion concentrations in VFS, which can depress macroinvertebrate populations and likely affect salamander abundance. Valley fills appear to have significant negative effects on stream salamander abundance due to alterations in habitat structure, water quality and chemistry, and macroinvertebrate communities in streams below fills.
International Nuclear Information System (INIS)
Waldo, J.B.; Greenwell, R.K.; Keasling, T.A.; Collins, J.R.; Klos, D.B.
1980-02-01
With construction of the Fast Flux Test Facility (FFTF) completed, the first major objective in the startup program was to fill the sodium systems. A sodium fill sequence was developed to match construction completion, and as systems became available, they were inerted, preheated, and filled with sodium. The secondary sodium systems were filled first while dry refueling system testing was in progress in the reactor vessel. The reactor vessel and the primary loops were filled last. This paper describes the methods used and some of the key results achieved for this major FFTF objective
Effect of weight fraction of different constituent elements on the total ...
Indian Academy of Sciences (India)
The mass attenuation coefficients, µm, of biological materials have been ... increasing percentage of constituent elements in high energy region up to 10 MeV. ... Muscle. 72.89. Figure 1. Plot of µm (cm2/g) vs. hydrogen weight fraction at some ...
Effective slip over partially filled microcavities and its possible failure
Ge, Zhouyang; Holmgren, Hanna; Kronbichler, Martin; Brandt, Luca; Kreiss, Gunilla
2018-05-01
Motivated by the emerging applications of liquid-infused surfaces (LIS), we study the drag reduction and robustness of transverse flows over two-dimensional microcavities partially filled with an oily lubricant. Using separate simulations at different scales, characteristic contact line velocities at the fluid-solid intersection are first extracted from nanoscale phase field simulations and then applied to micronscale two-phase flows, thus introducing a multiscale numerical framework to model the interface displacement and deformation within the cavities. As we explore the various effects of the lubricant-to-outer-fluid viscosity ratio μ˜2/μ˜1 , the capillary number Ca, the static contact angle θs, and the filling fraction of the cavity δ , we find that the effective slip is most sensitive to the parameter δ . The effects of μ˜2/μ˜1 and θs are generally intertwined but weakened if δ 1 ), however, are immune to such failure due to their generally larger contact line velocity.
Theory of fractional quantum Hall effect
International Nuclear Information System (INIS)
Kostadinov, I.Z.
1984-09-01
A theory of the fractional quantum Hall effect is constructed by introducing 3-particle interactions breaking the symmetry for ν=1/3 according to a degeneracy theorem proved here. An order parameter is introduced and a gap in the single particle spectrum is found. The critical temperature, critical filling number and critical behaviour are determined as well as the Ginzburg-Landau equation coefficients. A first principle calculation of the Hall current is given. 3, 5, 7 electron tunneling and Josephson interference effects are predicted. (author)
Directory of Open Access Journals (Sweden)
Bajraktari Gani
2012-09-01
Full Text Available Abstract Background The aim of this study was to prospectively examine echocardiographic parameters that correlate and predict functional capacity assessed by 6 min walk test (6-MWT in patients with heart failure (HF, irrespective of ejection fraction (EF. Methods In 147 HF patients (mean age 61 ± 11 years, 50.3% male, a 6-MWT and an echo-Doppler study were performed in the same day. Global LV dyssynchrony was indirectly assessed by total isovolumic time - t-IVT [in s/min; calculated as: 60 – (total ejection time + total filling time], and Tei index (t-IVT/ejection time. Patients were divided into two groups based on the 6-MWT distance (Group I: ≤300 m and Group II: >300 m, and also in two groups according to EF (Group A: LVEF ≥ 45% and Group B: LVEF Results In the cohort of patients as a whole, the 6-MWT correlated with t-IVT (r = −0.49, p Conclusion In patients with HF, the limited exercise capacity, assessed by 6-MWT, is related mostly to severity of global LV dyssynchrony, more than EF or raised filling pressures. The lack of exercise predictors in HFpEF reflects its multifactorial pathophysiology.
... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...
LENUS (Irish Health Repository)
Mullaney, L.
2014-01-10
Organ motion is a contributory factor to the variation in location of the prostate and organs at risk during a course of fractionated prostate radiation therapy (RT). A prospective randomized controlled trial was designed with the primary endpoint to provide evidence-based bladder-filling instructions to achieve a consistent bladder volume (BV) and thus reduce the bladder-related organ motion. The secondary endpoints were to assess the incidence of acute and late genitourinary (GU) and gastrointestinal (GI) toxicity for patients and patients’ satisfaction with the bladder-filling instructions.
Aharonov-Bohm oscillations with fractional period in a multichannel Wigner crystal ring
International Nuclear Information System (INIS)
Krive, I.V.; Krokhin, A.A.
1997-01-01
We study the persistent current in a quasi 1D ring with strongly correlated electrons forming a multichannel Wigner crystal (WC). The influence of the Coulomb interaction manifests itself only in the presence of external scatterers that pin the WC. Two regimes of weak and strong pinning are considered. For strong pinning we predict the Aharonov-Bohm oscillations with fractional period. Fractionalization is due to the interchannel coupling in the process of quantum tunneling of the WC. The fractional period depends on the filling of the channels and may serve as an indicator of non-Fermi-liquid behaviour of interacting electrons in quasi 1D rings. (author). 20 refs
A Statistical Treatment of Bioassay Pour Fractions
Barengoltz, Jack; Hughes, David W.
2014-01-01
The binomial probability distribution is used to treat the statistics of a microbiological sample that is split into two parts, with only one part evaluated for spore count. One wishes to estimate the total number of spores in the sample based on the counts obtained from the part that is evaluated (pour fraction). Formally, the binomial distribution is recharacterized as a function of the observed counts (successes), with the total number (trials) an unknown. The pour fraction is the probability of success per spore (trial). This distribution must be renormalized in terms of the total number. Finally, the new renormalized distribution is integrated and mathematically inverted to yield the maximum estimate of the total number as a function of a desired level of confidence ( P(fraction. The extension to recovery efficiency corrections is also presented. Now the product of recovery efficiency and pour fraction may be small enough that the likely value may be much larger than the usual calculation: the number of spores divided by that product. The use of this analysis would not be limited to microbiological data.
Luna Ramos, Lourdes; Miralles Mellado, Isabel; Ángel Domene Ruiz, Miguel; Solé Benet, Albert
2016-04-01
Mining activities generate erosion and loss of plant cover and soil organic matter (SOM), especially in arid and semiarid Mediterranean regions. A precondition for ecosystem restoration in such highly disturbed areas is the development of functional soils with sufficient organic matter. But the SOM quality is also important to long-term C stabilization. The resistance to biodegradation of recalcitrant organic matter fractions has been reported to depend on some intrinsic structural factors of humic acid substances and formation of amorphous organo-mineral recalcitrant complexes. In an experimental soil restoration in limestone quarries in the Sierra de Gádor (Almería), SE Spain, several combinations of organic amendments (sewage sludge and compost from domestic organic waste) and mulches (gravel and woodchip) were added in experimental plots using a factorial design. In each plot, 75 native plants (Anthyllis cytisoides, A. terniflora and Macrochloa tenacissima) were planted and five years after the start of the experiment total organic carbon (TOC), physico-chemical soil properties and organic C fractions (particulate organic matter, H3PO4-fulvic fraction, fulvic acids (FA), humic acids (HA) and humin) were analyzed. We observed significant differences between treatments related to the TOC content and the HA/FA ratio. Compost amendments increased the TOC, HA content and HA/FA ratio, even higher than in natural undisturbed soils, indicating an effective clay humus-complex pointing to progressively increasing organic matter quality. Soils with sewage sludge showed the lowest TOC and HA/FA ratio and accumulated a lower HA proportion indicating poorer organic matter quality and comparatively lower resilience than in natural soils and soils amended with compost.
Antioxidant Capacities of Fractions of Bamboo Shaving Extract and Their Antioxidant Components.
Gong, Jinyan; Huang, Jun; Xiao, Gongnian; Chen, Feng; Lee, Bolim; Ge, Qing; You, Yuru; Liu, Shiwang; Zhang, Ying
2016-07-30
This research was conducted for evaluation of antioxidant activities of four fractions from bamboo shavings extract (BSE) and their antioxidant components. The antioxidant capacities of BSE and four fractions on ABTS, DPPH, FRAP and total antioxidant capacity assays exhibited the following descending order: DF > n-butanol fraction (BF) > BSE ≈ ethyl acetate fraction (AF) > water fraction (WF). Among the identified phenolic compounds, caffeic acid exhibited the highest antioxidant capacities on DPPH, FRAP and total antioxidant capacity assays. An extremely significant positive correlation between the antioxidant activities with the contents of total flavonoids, total phenolic acids, or total phenolics was observed in this study. The result indicated that the bamboo shaving extract and its solvent fractions could act as natural antioxidants in light of their potent antioxidant activities.
International Nuclear Information System (INIS)
Huang, Minjuan; Chen, Xunwen; Zhao, Yinge; Yu Chan, Chuen; Wang, Wei; Wang, Xuemei; Wong, Ming Hung
2014-01-01
Speciation of inorganic trivalent arsenicals (iAs III ), inorganic pentavalent arsenicals (iAs V ), monomethylarsonic acid (MMA) and dimethylarsinic acid (DMA) in total arsenic (As) content and its bioaccessible fractions contained in road dust, household air-conditioning (AC) filter dust and PM 2.5 was investigated. Inorganic As, especially iAs V , was observed as the dominant species. Physiologically based extraction test (PBET), an in-vitro gastrointestinal method, was used to estimate the oral As bioaccessibility in coarse particles and the species present in the oral bioaccessible fraction. A composite lung simulating serum was used to mimic the pulmonary condition to extract the respiratory bioaccessible As and its species in PM 2.5 . Reduction of iAs V to iAs III occurred in both in-vitro gastrointestinal and lung simulating extraction models. The inorganic As species was the exclusive species for absorption through ingestion and inhalation of atmospheric particles, which was an important exposure route to inorganic As, in addition to drinking water and food consumption. - Highlights: • Inorganic As species was the predominant species in dust and airborne particles. • Existence of iAs III in dust and airborne particles increases human health risks. • Reduction from iAs V to iAs III occurred through in-vitro gastrointestinal model. • Reduction from iAs V to iAs III occurred in the simulating pulmonary region. • Atmospheric particles were important exposure sources of inorganic As. - Atmospheric particles are important exposure sources of inorganic As, of which the bioaccessibility is dependent on the extraction phases and models used
Non-homogeneous model for a side heated square cavity filled with a nanofluid
International Nuclear Information System (INIS)
Celli, Michele
2013-01-01
Highlights: • A side heated two dimensional square cavity filled with a nanofluid is studied. • A non-homogeneous model is taken into account. • The properties of the nanofluid are functions of the fraction of nanoparticles. • Low-Rayleigh numbers yield a non-homogeneous distribution of the nanoparticles. -- Abstract: A side heated two dimensional square cavity filled with a nanofluid is here studied. The side heating condition is obtained by imposing two different uniform temperatures at the vertical boundary walls. The horizontal walls are assumed to be adiabatic and all boundaries are assumed to be impermeable to the base fluid and to the nanoparticles. In order to study the behavior of the nanofluid, a non-homogeneous model is taken into account. The thermophysical properties of the nanofluid are assumed to be functions of the average volume fraction of nanoparticles dispersed inside the cavity. The definitions of the nondimensional governing parameters (Rayleigh number, Prandtl number and Lewis number) are exactly the same as for the clear fluids. The distribution of the nanoparticles shows a particular sensitivity to the low Rayleigh numbers. The average Nusselt number at the vertical walls is sensitive to the average volume fraction of the nanoparticles dispersed inside the cavity and it is also sensitive to the definition of the thermophysical properties of the nanofluid. Highly viscous base fluids lead to a critical behavior of the model when the simulation is performed in pure conduction regime. The solution of the problem is obtained numerically by means of a Galerkin finite element method
Evaluation of the properties of iron oxide-filled castor oil polyurethane
Mussatti, Eleonora; Merlini, Claudia; Barra, Guilherme Mariz de Oliveira; Güths, Saulo; Oliveira, Antonio Pedro Novaes de; Siligardi, Cristina
2012-01-01
The aim of this study was to obtain and evaluate the electrical, thermal and mechanical properties of iron oxide-filled castor oil polyurethane (PU/Fe2O3). The iron oxide used in this study was a residue derived from the steel pickling process of a Brazilian steel rolling industry. Polymeric composites with different iron oxide volume fractions (2.5, 5.0, 7.5, 10.0 and 12.5%) were prepared through the casting process followed by compression molding at room temperature. The composites were ana...
Lysine Rich Proteins in the Salt-Soluble Protein Fraction of Barley
DEFF Research Database (Denmark)
Ingversen, J.; Køie, B.
1973-01-01
Fractionation of the protein complex from Emir barley showed that the salt-soluble fraction accounts for 44% of the total lysine content but only for 2.......Fractionation of the protein complex from Emir barley showed that the salt-soluble fraction accounts for 44% of the total lysine content but only for 2....
Air filled porosity in composting processes
Energy Technology Data Exchange (ETDEWEB)
Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.
2009-07-01
As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)
Air filled porosity in composting processes
International Nuclear Information System (INIS)
Ruggieri, L.; Gea, T.; Artola, A.; Sanchez, A.
2009-01-01
As it is widely known, the composting process consists in the aerobic decomposition of the biodegradable organic matter present in different types of solid wastes. Water and oxygen are necessary for the biological activity of microorganisms involved in the composting process and their availability is directly related to the total and the air filled porosity (AFP). Maintaining adequate AFP level satisfies the oxygen content requirement to achieve the desired composting conditions and thus, tho enhance biological activity. (Author)
Tests of equal effect per fraction in microcolony assays of survival after fractionated irradiations
International Nuclear Information System (INIS)
Taylor, J.M.G.
1985-01-01
H.D Thames, Jr. and H.R. Withers propose a test of an equal effect per fraction in microcolony assays after fractionated radiation, in which the total effect is measured by counting microcolonies derived from surviving cells in a tissue. The factors considered to influence the cytocidal effect per fraction are incomplete repair, repopulation, and synchrony. The statistics used in the method are criticized and conditions are given under which the test should not be used. An alternative method of testing for an equal effect per fraction is proposed. The pros and cons of each test are discussed and compared using some mouse jejunal crypt cell survival data
Lam, Cherry Wing Yu; Ikeda, Shinya
2017-05-01
Texture modifying abilities of whey protein microparticles are expected to be dependent on pH during heat-induced aggregation of whey protein in the microparticulation process. Therefore, whey protein microparticles were prepared at either pH 5.5 or 6.8 and their effects on small and large deformation properties of gellan gels containing whey protein microparticles as fillers were investigated. The majority of whey protein microparticles had diameters around 2 μm. Atomic force microscopy images showed that whey protein microparticles prepared at pH 6.8 partially collapsed and flatted by air-drying, while those prepared at pH 5.5 did not. The Young's modulus of filled gels adjusted to pH 5.5 decreased by the addition of whey protein microparticles, while those of filled gels adjusted to pH 6.8 increased with increasing volume fraction of filler particles. These results suggest that filler particles were weakly bonded to gel matrices at pH 5.5 but strongly at pH 6.8. Whey protein microparticles prepared at pH 5.5 showed more enhanced increases in the Young's modulus than those prepared at pH 6.8 at volume fractions between 0.2 and 0.4, indicating that microparticles prepared at pH 5.5 were mechanically stronger. The fracture stress of filled gels showed trends somewhat similar to those of the Young's modulus, while their fracture strains decreased by the addition of whey protein microparticles in all examined conditions, indicating that the primary effect of these filler particles was to enhance the brittleness of filled gels. © 2017 Institute of Food Technologists®.
Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension
DEFF Research Database (Denmark)
Mehlsen, J; Haedersdal, C; Stokholm, K H
1994-01-01
by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe......Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...
Dependency of blood pressure upon cardiac filling in patients with severe postural hypotension
DEFF Research Database (Denmark)
Mehlsen, J; Haedersdal, C; Stokholm, K H
1994-01-01
Autonomic denervation of the vascular bed results theoretically in a stronger dependency of blood pressure upon intravascular volume, and the study described aimed at an investigation of the relation between cardiac filling and arterial blood pressure in patients with severe postural hypotension....... Seven patients were studied during head-up tilt at three different tilt angles using intra-arterial blood pressure recordings and estimates of left ventricular volumes by radioisotope ventriculography. Blood pressure fell dramatically during head-up tilt due to reductions in cardiac output unopposed...... by vasoconstriction. The reduction in cardiac output resulted from reductions in left ventricular end-diastolic volumes with unchanged left ventricular ejection fractions and only moderate increments in heart rate. The study was demonstrated that blood pressure is strongly dependent upon cardiac filling in severe...
Grain boundary diffusion in terms of the tempered fractional calculus
International Nuclear Information System (INIS)
Sibatov, R.T.; Svetukhin, V.V.
2017-01-01
Mathematical treatment of grain-boundary diffusion based on the model first proposed by Fisher is usually formulated in terms of normal diffusion equations in a two-component nonhomogeneous medium. On the other hand, fractional equations of anomalous diffusion proved themselves to be useful in description of grain-boundary diffusion phenomena. Moreover, the most important propagation regime predicted by Fisher's model demonstrates subdiffusive behavior. However, the direct link between fractional approach and the Fisher model and its modifications has not found yet. Here, we fill this gap and show that solution of fractional subdiffusion equation offers general properties of classical solutions obtained by Whipple and Suzuoka. The tempered fractional approach is a convenient tool for studying precipitation in granular materials as the tempered subdiffusion limited process. - Highlights: • The link connected fractional diffusion approach and Fisher's model of grain-boundary diffusion is derived. • The subdiffusion exponent of grain-boundary diffusion can differ from 1/2. • Nucleation in granular materials is modeled by the process limited by tempered subdiffusion.
Grain boundary diffusion in terms of the tempered fractional calculus
Energy Technology Data Exchange (ETDEWEB)
Sibatov, R.T., E-mail: ren_sib@bk.ru [Ulyanovsk State University, 432017, 42 Leo Tolstoy str., Ulyanovsk (Russian Federation); Svetukhin, V.V. [Ulyanovsk State University, 432017, 42 Leo Tolstoy str., Ulyanovsk (Russian Federation); Institute of Nanotechnology and Microelectronics of the Russian Academy of Sciences, 115487, 18 Nagatinskaya str., Moscow (Russian Federation)
2017-06-28
Mathematical treatment of grain-boundary diffusion based on the model first proposed by Fisher is usually formulated in terms of normal diffusion equations in a two-component nonhomogeneous medium. On the other hand, fractional equations of anomalous diffusion proved themselves to be useful in description of grain-boundary diffusion phenomena. Moreover, the most important propagation regime predicted by Fisher's model demonstrates subdiffusive behavior. However, the direct link between fractional approach and the Fisher model and its modifications has not found yet. Here, we fill this gap and show that solution of fractional subdiffusion equation offers general properties of classical solutions obtained by Whipple and Suzuoka. The tempered fractional approach is a convenient tool for studying precipitation in granular materials as the tempered subdiffusion limited process. - Highlights: • The link connected fractional diffusion approach and Fisher's model of grain-boundary diffusion is derived. • The subdiffusion exponent of grain-boundary diffusion can differ from 1/2. • Nucleation in granular materials is modeled by the process limited by tempered subdiffusion.
Investigation of the formation of Fe-filled carbon nanotubes
Energy Technology Data Exchange (ETDEWEB)
Reuther, H [Forschungszentrum Dresden-Rossendorf, PO Box 510119, D-01314 Dresden (Germany); Mueller, C; Leonhardt, A; Kutz, M C, E-mail: reuther@fzd.d [Leibniz-Institute of Solid State and Materials Research Dresden, PO Box 270116, D-01171 Dresden (Germany)
2010-03-01
The formation of Fe-filled carbon nanotubes by thermal decomposition of ferrocene combined with a Fe-catalyst-nanostructuring on an oxidized Si substrate is investigated in the temperature range of 1015 - 1200 K. The optimal growth conditions for aligned and homogeneous carbon nanotubes are found at 1103 K. Moessbauer spectroscopy (both in transmission geometry and CEMS) was used to analyze and quantify the different formed Fe-phases. In general, {alpha}-Fe, {gamma}-Fe and Fe{sub 3}C are found to form within the carbon nanotubes. Depending on the growth conditions their fractions vary strongly. Moreover, an alignment of the {alpha}-Fe in the tubes could be detected.
Topological Fractional Pumping with Alkaline-Earth-Like Atoms in Synthetic Lattices
Taddia, Luca; Cornfeld, Eyal; Rossini, Davide; Mazza, Leonardo; Sela, Eran; Fazio, Rosario
2017-06-01
Alkaline-earth(-like) atoms, trapped in optical lattices and in the presence of an external gauge field, can form insulating states at given fractional fillings. We will show that, by exploiting these properties, it is possible to realize a topological fractional pump. Our analysis is based on a many-body adiabatic expansion, on simulations with time-dependent matrix product states, and, for a specific form of atom-atom interaction, on an exactly solvable model of fractional pump. The numerical simulations allow us to consider a realistic setup amenable of an experimental realization. As a further consequence, the measure of the center-of-mass shift of the atomic cloud would constitute the first measurement of a many-body Chern number in a cold-atom experiment.
Radiobiological arguments for and clinical possibilities of unconventional fractionating rhythms
International Nuclear Information System (INIS)
Herrmann, T.; Voigtmann, L.
1986-01-01
Radiobiological considerations are presented using unconventional fractionating rhythms. The aim of this method is to enlarge the therapeutic dimensions between maximum tumor destruction and most careful treatment of late responding cell systems. These late responding tissues show a very similar dose-time reaction, probably by reason of a causal injury on cells of the capillary endothelium. In linear-quadratic models for the estimation of the parameters of the number of fractions and total treatment period it becomes evident that a careful treatment of late responding tissue can be attained by reduction of the single dose per fraction. Because with partition of a total dose in several fractions at daily irradiation a longer repopulation period is available also for the tumor irradiations are presented, done repeatedly during the day. Accelerated fractionation (same fractionating number in reduced treatment period) are contrasted to hyperfractionation (increased fractionating number within the same total treatment period) and possibilities in application are suggested. (author)
DEFF Research Database (Denmark)
Sørensen, Simon Toft; Larsen, Casper; Jakobsen, Christian
2014-01-01
Dispersion control with axially nonuniform photonic crystal fibers (PCFs) permits supercontinuum (SC) generation into the deep-blue from an ytterbium pump laser. In this Letter, we exploit the full degrees of freedom afforded by PCFs to fabricate a fiber with longitudinally increasing air-fill fr...
Directory of Open Access Journals (Sweden)
Pichler Anita
2017-03-01
Full Text Available This paper deals with the influence of the addition of sugars (sucrose, fructose and trehalose, modified starches (tapioca or waxy maize starch and hydrocolloids (karaya or guar gum on colour and thermal properties of raspberry cream fillings. In addition, the influence of the above-mentioned additives on the colour and thermal properties of raspberry cream fillings stored at room temperature over a period of 8 and 16 months was investigated. Results showed that the highest anthocyanin content and total phenolic content were detected in raspberry cream filling prepared with sucrose and trehalose in combination with guar gum. During storage, after 8 and 16 months at room temperature, anthocyanin content and total phenolic content decreased. Results also showed that the kind of sugar and added modified starches or hydrocolloids influenced the thermal properties of cream fillings. During storage, a decrease was observed in both freezing temperature as well as enthalpy of cream fillings.
Directory of Open Access Journals (Sweden)
Lucindo J. Quintans-Júnior
Full Text Available Rauvolfia ligustrina Roem et. Schult (Apocynaceae, commonly known as "paratudo" and "arrebenta-boi" is a small tree found in Brazilian Northeastern. Previous studies have demonstrated depressant and anticonvulsant properties of the ethanol extract of Rauvolfia ligustrina. The aim of the present study was the determination of the lethal dose 50% (LD50 and the effects of total alkaloid fraction (TAF of the aerial parts of R. ligustrina in animal models of convulsion. It was found that the acute toxicity of TAF was 127.8 (112.5-145.2 mg/kg (i.p. in mice. TAF (20 mg/kg, ip significantly increased (p < 0.05 the latencies of clonic seizures induced by pentylenetetrazol (PTZ and picrotoxin (PIC. However, TAF did not protect the animals in maximal electroshock (MES induced seizures. These results suggest that TAF of R. ligustrina possesses anticonvulsant properties.
Evaluating the Impact of Prescription Fill Rates on Risk Stratification Model Performance.
Chang, Hsien-Yen; Richards, Thomas M; Shermock, Kenneth M; Elder Dalpoas, Stacy; J Kan, Hong; Alexander, G Caleb; Weiner, Jonathan P; Kharrazi, Hadi
2017-12-01
Risk adjustment models are traditionally derived from administrative claims. Prescription fill rates-extracted by comparing electronic health record prescriptions and pharmacy claims fills-represent a novel measure of medication adherence and may improve the performance of risk adjustment models. We evaluated the impact of prescription fill rates on claims-based risk adjustment models in predicting both concurrent and prospective costs and utilization. We conducted a retrospective cohort study of 43,097 primary care patients from HealthPartners network between 2011 and 2012. Diagnosis and/or pharmacy claims of 2011 were used to build 3 base models using the Johns Hopkins ACG system, in addition to demographics. Model performances were compared before and after adding 3 types of prescription fill rates: primary 0-7 days, primary 0-30 days, and overall. Overall fill rates utilized all ordered prescriptions from electronic health record while primary fill rates excluded refill orders. The overall, primary 0-7, and 0-30 days fill rates were 72.30%, 59.82%, and 67.33%. The fill rates were similar between sexes but varied across different medication classifications, whereas the youngest had the highest rate. Adding fill rates modestly improved the performance of all models in explaining medical costs (improving concurrent R by 1.15% to 2.07%), followed by total costs (0.58% to 1.43%), and pharmacy costs (0.07% to 0.65%). The impact was greater for concurrent costs compared with prospective costs. Base models without diagnosis information showed the highest improvement using prescription fill rates. Prescription fill rates can modestly enhance claims-based risk prediction models; however, population-level improvements in predicting utilization are limited.
International Nuclear Information System (INIS)
Harder, Annemarie M. den; Kotte, Alexis N.T.J.; Vulpen, Marco van; Lips, Irene M.; Gils, Carla H. van
2014-01-01
To investigate whether magnesium oxide reduces the interfraction motion of the prostate and the amount of rectal filling and rectal gas, which influences prostate position during radiotherapy for prostate cancer. From December 2008 to February 2010, 92 prostate cancer patients scheduled for intensity-modulated radiotherapy (77 Gy in 35 fractions) using fiducial marker-based position verification were randomly assigned to receive magnesium oxide (500 mg twice a day) or placebo during radiotherapy. In a previous study, we investigated the effect on intrafraction motion and did not find a difference between the treatment arms. Here, we compared the interfraction prostate motion between the two treatment arms as well as the amount of rectal filling and rectal air pockets using pretreatment planning computed tomography and magnetic resonance imaging scans. There was no statistically significant difference between the treatment arms in translation and rotation of the prostate between treatment fractions, except for the rotation around the cranial caudal axis. However, the difference was less than 1 and therefore considered not clinically relevant. There was no significant difference in the amount of rectal filling and rectal air pockets between the treatment arms. Magnesium oxide is not effective in reducing the interfraction prostate motion or the amount of rectal filling and rectal gas during external-beam radiotherapy. Therefore, magnesium oxide is not recommended in clinical practice for these purposes. (orig.) [de
Characterization and Expression Patterns of microRNAs Involved in Rice Grain Filling
Du, Yanxiu; Zhang, Jing; Li, Junzhou; Liu, Yanxia; Zhao, Yafan; Zhao, Quanzhi
2013-01-01
MicroRNAs (miRNAs) are upstream gene regulators of plant development and hormone homeostasis through their directed cleavage or translational repression of the target mRNAs, which may play crucial roles in rice grain filling and determining the final grain weight and yield. In this study, high-throughput sequencing was performed to survey the dynamic expressions of miRNAs and their corresponding target genes at five distinct developmental stages of grain filling. In total, 445 known miRNAs and 45 novel miRNAs were detected with most of them expressed in a developmental stage dependent manner, and the majority of known miRNAs, which increased gradually with rice grain filling, showed negatively related to the grain filling rate. Detailed expressional comparisons revealed a clear negative correlation between most miRNAs and their target genes. It was found that specific miRNA cohorts are expressed in a developmental stage dependent manner during grain filling and the known functions of these miRNAs are involved in plant hormone homeostasis and starch accumulation, indicating that the expression dynamics of these miRNAs might play key roles in regulating rice grain filling. PMID:23365650
Use of Angle Model to Understand Addition and Subtraction of Fractions
Directory of Open Access Journals (Sweden)
Muzwangowenyu Mukwambo
2018-02-01
Full Text Available Learners in lower primary and even some in upper primary grades grapple to perform mathematical operations which involve fractions. Failure to solve these mathematical operations creates a gap in the teaching and learning processes of mathematics. We opine that this is attributed to use of traditional mathematical approaches of teaching and learning (TMATL of operations of fraction. With the hope of engaging the reformed mathematical approach of teaching and learning (RMATL this study investigated the following: How can trainee teachers use the angle model in RMATL operations of fractions? What are the perceptions of trainee teachers in the use of the angle model which engages RMATL to teach the operations of fractions? With the goal to fill the mentioned gap in which learners struggle to perform operations involving fractions, we observed and analysed worksheets on operation with fractions students wrote. Observations and interviews with trainee teachers of lower primary revealed poor performance in problems related to operations with fractions. Observed patterns supported by cognitivism revealed that invented methods or strategies on which RMATL is anchored are suitable enough to engage learner–centred teaching and learning which can prevent the abstractness of the concept of operations with fractions.
Intervals between multiple fractions per day
International Nuclear Information System (INIS)
Fowler, J.F.
1988-01-01
Assuming the linear quadratic model for dose-response curves enables the proportion of repairable damage to be calculated for any size of dose per fraction. It is given by the beta (dose squared) term, and represents a larger proportion of the total damage for larger doses per fraction, but also for late-reacting than for early-reacting tissues. For example at 2 Gy per fraction, repairable damage could represent nearly half the total damage in late-reacting tissues but only one fifth in early-reacting tissues. Even if repair occurs at the same rate in both tissues, it will obviously take longer for 50% of the damage to fade to an undetectable level (3 or 5%) than for 20% to do so. This means that late reactions require longer intervals than early reactions when multiple fraction per day radiotherapy is planned, even if the half-lives of repair are not different. (orig.)
Hydroxyapatite clay for gap filling and adequate bone ingrowth.
Maruyama, M; Terayama, K; Ito, M; Takei, T; Kitagawa, E
1995-03-01
In uncemented total hip arthroplasty, a complete filling of the gap between femoral prosthesis and the host bone is difficult and defects would remain, because the anatomy of the reamed intramedullary canal cannot fit the prosthesis. Therefore, it seems practical to fill the gap with a clay containing hydroxyapatite (HA), which has an osteoconductive character. The clay (HA clay) is made by mixing HA granules (size 0.1 mm or more) having a homogeneous pore distribution and a porosity of 35-48 vol%, and a viscous substance such as a saline solution of sodium alginate (SSSA). In the first experiment, the ratio of HA granules and sodium alginate in SSSA is set for the same handling properties of HA clay and polymethylmethacrylate bone cement (standard viscosity) before hardening. As a result, the ratio is set for 55 wt% of HA in the clay and 12.5 wt% of sodium alginate in SSSA (i.e., HA:sodium alginate:saline solution = 9.8:1:7). In the second study, the gap between the femoral stem and bone model is completely filled with HA clay. However, the gap is not filled only with HA granules or HA granules mixed with saline solution. In the third animal experiment, using an unloaded model, histology shows that HA clay has an osteoconductive property bridging the gap between the implant and the cortical bone without any adverse reaction. HA clay is considered a useful biomaterial to fill the gap with adequate bone ingrowth.
Left ventricular diastolic filling in patients with systemic hypertension
International Nuclear Information System (INIS)
Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke
1985-01-01
To study the prevalence and significance of left ventricular (LV) diastolic dysfunction in mild to moderate systemic hypertension (HT), cardiac blood pool imagings with Tc-99 m were obtained in 10 normal subjects and 27 patients with HT. The patients with HT did not show any evidence of coronary heart disease, renal insufficiency, cerebrovascular accident or diabetes mellitus. They were divided into 3 groups; (1) HT-1 (n=10): without evidence of echocardiographic (UCG) and electrocardiographic (ECG) left ventricular hypertrophy (LVH), (2) HT-2 (n=8): with evidence of ECG-LVH without UCG-LVH, (3) HT-3 (n=9): with evidence of UCG-LVH. UCG-LVH was defined when posterior or interventricular septal tall thickness exceeded 13 mm at end-diastole. From UCG findings LV mass was calculated and from UCG findings and auscultating brachial systolic pressure LV peak-systolic wall stress (WS) was obtained. Cardiac blood pool imagings were performed at modified LAO at rest and during exercise stress. Indices of LV systolic function (rest ejection fraction, mean ejection rate during the first third of ejection and exercise ejection fraction response) were essentially similar in normal subjects and all HT groups. In contrast, LV diastolic filling rate during the first third of diastole (1/3 FR mean) decreased significantly in any group of HT, and it was prominent in HT-3. In patients with HT, 1/3 FR mean did not correlate with blood pressure, LV peak-systolic WS, LV systolic functions and LV end-diastolic volume. But it correlated inversely with LV mass (r=-0.84). These results suggest that impairment of early diastolic LV filling can be detected before systolic cardiac impairment and LVH develop, and it is, at least in part, relate to the LV mass. (author)
Du, Fuyi; Xie, Qingjie; Fang, Longxiang; Su, Hang
2016-08-01
Nutrients (nitrogen and phosphorus) from agricultural non-point source (NPS) pollution have been increasingly recognized as a major contributor to the deterioration of water quality in recent years. The purpose of this article is to investigate the discrepancies in interception of nutrients in agricultural NPS pollution for eco-soil reactors using different filling schemes. Parallel eco-soil reactors of laboratory scale were created and filled with filter media, such as grit, zeolite, limestone, and gravel. Three filling schemes were adopted: increasing-sized filling (I-filling), decreasing-sized filling (D-filling), and blend-sized filling (B-filling). The systems were intermittent operations via simulated rainstorm runoff. The nutrient removal efficiency, biomass accumulation and vertical dissolved oxygen (DO) distribution were defined to assess the performance of eco-soil. The results showed that B-filling reactor presented an ideal DO for partial nitrification-denitrification across the eco-soil, and B-filling was the most stable in the change of bio-film accumulation trends with depth in the three fillings. Simultaneous and highest removals of NH4(+)-N (57.74-70.52%), total nitrogen (43.69-54.50%), and total phosphorus (42.50-55.00%) were obtained in the B-filling, demonstrating the efficiency of the blend filling schemes of eco-soil for oxygen transfer and biomass accumulation to cope with agricultural NPS pollution.
Directory of Open Access Journals (Sweden)
Maria Cecília Oliveira Costa
2003-12-01
Full Text Available Cashew (Anacardium occidentale L. apples from Pacajus, Ceará State, Brazil, were processed into high pulp content juice. The juice was packed either by hot fill or an aseptic process and evaluated for physical, physical-chemical, and sensorial changes during a 12-month storage period at room temperature. The results indicated that pH, soluble solids, total acidity, total sugar content and color did not change significantly during storage nor were affected by the type of filling. The sensorial analysis showed that juice acceptance remained high throughout the storage period regardless of the filling system. Differences in juice viscosity persisted between both processes.Pedúnculos de caju (Anacardium occidentale L. de Pacajus, Estado do Ceará, Brasil, foram processados na forma de suco com alto teor de polpa. O suco foi acondicionado através do processo hot fill ou asséptico e verificada as alterações físicas, físico-químicas e sensoriais durante armazenagem por doze meses à temperatura ambiente. Os resultados indicaram que pH, sólidos solúveis, acidez total, conteúdo de açúcar e cor não mudaram de modo significativo durante a armazenagem nem foram afetadas pelo modo de acondicionamento. Análise sensorial mostrou que a aceitação do suco foi mantida alta durante o período de armazenagem a despeito do sistema de enchimento. Diferenças na viscosidade dos sucos persistiram entre ambos processos.
Ushakov, Anton; Orlov, Alexey; Sovach, Victor P.
2018-03-01
This article presents the results of research filling of gas centrifuge cascade for separation of the multicomponent isotope mixture with process gas by various feed flow rate. It has been used mathematical model of the nonstationary hydraulic and separation processes occurring in the gas centrifuge cascade. The research object is definition of the regularity transient of nickel isotopes into cascade during filling of the cascade. It is shown that isotope concentrations into cascade stages after its filling depend on variable parameters and are not equal to its concentration on initial isotope mixture (or feed flow of cascade). This assumption is used earlier any researchers for modeling such nonstationary process as set of steady-state concentration of isotopes into cascade. Article shows physical laws of isotope distribution into cascade stage after its filling. It's shown that varying each parameters of cascade (feed flow rate, feed stage number or cascade stage number) it is possible to change isotope concentration on output cascade flows (light or heavy fraction) for reduction of duration of further process to set of steady-state concentration of isotopes into cascade.
Homogenization versus homogenization-free method to measure muscle glycogen fractions.
Mojibi, N; Rasouli, M
2016-12-01
The glycogen is extracted from animal tissues with or without homogenization using cold perchloric acid. Three methods were compared for determination of glycogen in rat muscle at different physiological states. Two groups of five rats were kept at rest or 45 minutes muscular activity. The glycogen fractions were extracted and measured by using three methods. The data of homogenization method shows that total glycogen decreased following 45 min physical activity and the change occurred entirely in acid soluble glycogen (ASG), while AIG did not change significantly. Similar results were obtained by using "total-glycogen-fractionation methods". The findings of "homogenization-free method" indicate that the acid insoluble fraction (AIG) was the main portion of muscle glycogen and the majority of changes occurred in AIG fraction. The results of "homogenization method" are identical with "total glycogen fractionation", but differ with "homogenization-free" protocol. The ASG fraction is the major portion of muscle glycogen and is more metabolically active form.
The structure of filled skutterudites and the local vibration behavior of the filling atom
Energy Technology Data Exchange (ETDEWEB)
Zhou, Xiaojuan [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Zong, Peng-an [State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Chen, Xihong [Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Tao, Juzhou, E-mail: taoj@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Dongguan Institute of Neutron Science, Dongguan 523808 (China); Lin, He, E-mail: linhe@sinap.ac.cn [Shanghai Institute of Applied Physics, Chinese Academy of Science, Shanghai 201204 (China)
2017-02-15
Both of atomic pair distribution function (PDF) and extended x-ray absorption fine structure (EXAFS) experiments have been carried out on unfilled and Yb-filled skutterudites Yb{sub x}Co{sub 4}Sb{sub 12} (x=0, 0.15, 0.2 and 0.25) samples. The structure refinements on PDF data confirm the large amplitude vibration of Yb atom and the dependence of Yb vibration amplitude on the filling content. Temperature dependent EXAFS experiment on filled skutterudites have been carried out at Yb L{sub Ⅲ}-edge in order to explore the local vibration behavior of filled atom. EXAFS experiments show that the Einstein temperature of the filled atom is very low (70.9 K) which agrees with the rattling behavior.
Energy Technology Data Exchange (ETDEWEB)
Oh, K K; Lee, Y H; Cho, O K; Park, C Y [Yonsei University College of Medicine, Seoul (Korea, Republic of)
1979-06-15
The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass
International Nuclear Information System (INIS)
Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y.
1979-01-01
The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass
Energy Technology Data Exchange (ETDEWEB)
Oh, K. K.; Lee, Y. H.; Cho, O. K.; Park, C. Y. [Yonsei University College of Medicine, Seoul (Korea, Republic of)
1979-06-15
The gastric lesion is a common source of complaints to Orientals, however, evaluation of gastric symptoms and laboratory examination offer little specific aid in the diagnosis of gastric diseases. Thus roentgenography of gastrointestinal tract is one of the most reliable method for detail diagnosis. On double contract study of stomach, gastric filling defect is mostly caused by malignant gastric cancer, however, other benign lesions can cause similar pictures which can be successfully treated by surgery. 66 cases of benign causes of gastric filling defect were analyzed at this point of view, which was verified pathologically by endoscope or surgery during recent 7 years in Yensei University College of Medicine, Severance Hospital. The characteristic radiological picture of each disease was discussed for precise radiologic diagnosis. 1. Of total 66 cases, there were 52 cases of benign gastric tumor 10 cases of gastric varices, 5 cases of gastric bezoar, 5 cases of corrosive gastritis, 3 cases of granulomatous disease and one case of gastric hematoma. 2. The most frequent causes of benign tumors were adenomatous polyp (35/42) and the next was leiomyoma (4/42). Others were one of case of carcinoid, neurofibroma and cyst. 3. Characteristic of benign adenomatous polyp were relatively small in size, smooth surface and were observed that large size, benign polyp was frequently type IV lesion with a stalk. 4. Submucosal tumors such as leiomyoma needed differential diagnosis with polypoid malignant cancer. However, the characteristic points of differentiation was well circumscribed smooth margined filling defect without definite mucosal destruction on surface. 5. Gastric varices showed multiple lobulated filling defected especially on gastric fundus that changed its size and shape by respiration and posture of patients. Same varices lesions on esophagus and history of liver disease were helpful for easier diagnosis. 6. Gastric bezoar showed well defined movable mass
Energy Technology Data Exchange (ETDEWEB)
Byun, Hwa Kyung; Yoon, Hong In; Cho, Jae Ho [Yonsei Cancer Center, Yonsei University College of Medicine, Seoul (Korea, Republic of); and others
2017-09-15
Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46–110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90–42.56). IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI.
International Nuclear Information System (INIS)
Byun, Hwa Kyung; Yoon, Hong In; Cho, Jae Ho
2017-01-01
Pulmonary toxicities, including infectious pneumonia (IP) and idiopathic pneumonia syndrome (IPS), are serious side effects of total body irradiation (TBI) used for myeloablative conditioning. This study aimed to evaluate clinical factors associated with IP and IPS following TBI. Fifty-eight patients with hematologic malignancies who underwent TBI before allogeneic hematopoietic stem cell transplantation between 2005 and 2014 were reviewed. Most patients (91%) received 12 Gy in 1.5 Gy fractions twice a day. Pulmonary toxicities were diagnosed based on either radiographic evidence or reduced pulmonary function, and were subdivided into IP and IPS based on the presence or absence of concurrent infection. Pulmonary toxicities developed in 36 patients (62%); 16 (28%) had IP and 20 (34%) had IPS. IP was significantly associated with increased treatment-related mortality (p = 0.028) and decreased survival (p = 0.039). Multivariate analysis revealed that the risk of developing IPS was significantly higher in patients who received stem cells from a matched unrelated donor than from a matched sibling donor (p = 0.021; hazard ratio [HR] = 12.67; 95% confidence interval [CI], 1.46–110.30). Combining other conditioning agents with cyclophosphamide produced a higher tendency to develop IP (p = 0.064; HR = 6.19; 95% CI, 0.90–42.56). IP and IPS involve different risk factors and distinct pathogeneses that should be considered when planning treatments before and after TBI
Adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion
International Nuclear Information System (INIS)
Webb, S
2008-01-01
This paper presents a technique for coping with variable intrafraction organ motion when delivering intensity-modulated radiation therapy (IMRT). The strategy is an adaptive delivery in which the fluence delivered up to a particular fraction is subtracted from the required total-course planned fluence to create an adapted residual fluence for the next fraction. This requires that the fluence already delivered can be computed, knowing the intrafraction motion during each fraction. If the adaptation is unconstrained, as would be required for perfect delivery of the planned fluence, then the individual fractional fluences would become unphysical, with both negative components and spikes. Hence it is argued that constraints must be applied; first, positivity constraints and second, constraints to limit fluence spikes. Additionally, it is shown to be helpful to constrain other quantities which are explained. The power of the strategy is that it adapts to the (potentially variable) moving geometry during each fraction. It is not a perfect delivery but it is always better than making no adaptation. The fractionated nature of radiation therapy is thus exploited to advantage. The fluence adaptation method does not require re-planning at each fraction but this imposes limitations which are stated. The fuller theory of dose adaptation is also developed for intrafraction motion. The method is complementary to other adaptive strategies recently discussed with respect to interfraction motion
Operation feedback of hydrogen filling station
International Nuclear Information System (INIS)
Pregassame, S.; Barral, K.; Allidieres, L.; Charbonneau, T.; Lacombe, Y.
2004-01-01
One of the technical challenges of hydrogen technology is the development of hydrogen infrastructures which satisfy either safety requirements and reliability of filling processes. AIR LIQUIDE realized an hydrogen filling station in Sassenage (France) operational since September 2003. This station is able to fill 3 buses a day up to 350bar by equilibrium with high pressure buffers. In parallel with commercial stations, the group wanted to create a testing ground in real conditions running with several objectives: validate on a full scale bench a simulation tool able to predict the temperature of both gas and cylinder's materials during filling processes; define the best filling procedures in order to reach mass, temperature and filling time targets; analyse the temperature distribution and evolution inside the cylinder; get a general knowledge about hydrogen stations from safety and reliability point of view; operate the first full scale refuelling station in France. The station is also up-graded for 700bar filling from either a liquid hydrogen source or a gas booster, with cold filling possibility. This paper presents the results concerning 350bar filling : thermal effects, optimal filling procedures and influence of parameters such as climatic conditions are discussed. (author)
Droplet Measurement below Single-Layer Grid Fill
Directory of Open Access Journals (Sweden)
Vitkovic Pavol
2016-01-01
Full Text Available The main part of the heat transfer in a cooling tower is in a fill zone. This one is consist of a cooling fill. For the cooling tower is used a film fill or grid fill or splash fill in the generally. The grid fill has lower heat transfer performance like film fill usually. But their advantage is high resistance to blockage of the fill. The grid fill is consisted with independent layers made from plastic usually. The layers consist of several bars connected to the different shapes. For experiment was used the rhombus shape. The drops diameter was measured above and below the Grid fill.
Nye, Kyle; Eslam-Panah, Azar
2016-11-01
Root canal treatment involves the removal of infected tissue inside the tooth's canal system and filling the space with a dense sealing agent to prevent further infection. A good root canal treatment happens when the canals are filled homogeneously and tightly down to the root apex. Such a tooth is able to provide valuable service for an entire lifetime. However, there are some examples of poorly performed root canals where the anterior and posterior routes are not filled completely. Small packets of air can be trapped in narrow access cavities when restoring with resin composites. Such teeth can cause trouble even after many years and lead the conditions like acute bone infection or abscesses. In this study, the filling of dead-end conical cavities with various liquids is reported. The first case studies included conical cavity models with different angles and lengths to visualize the filling process. In this investigation, the rate and completeness at which a variety of liquids fill the cavity were observed to find ideal conditions for the process. Then, a 3D printed model of the scaled representation of a molar with prepared post spaces was used to simulate the root canal treatment. The results of this study can be used to gain a better understanding of the restoration for endodontically treated teeth.
The dependence of radiation response on the dose per fraction
International Nuclear Information System (INIS)
Joiner, M.C.
1989-01-01
The linear-quadratic (LQ) model explains the dependence of total dose in a fractionated course on the dose per fraction, in a very wide range of tumour and normal tissue studies, providing the dose per fraction remains above 2 Gy. In the range 2-1 Gy per fraction, some experimental studies show less increase in total dose than predicted by LQ; a probable explanation is incomplete repair between fractions given 2 seen between 1 and 0.1 Gy per fraction. This cannot be explained by incomplete repair; a modified LQ model where α decreases sharply with increasing dose per fraction in the range 0-1 Gy fits these data. The basic LQ model describes data from neutron fractionation studies, so the relationship between relative biological effectiveness (RBE) and X-ray dose per fraction can be expressed in terms of LQ parameters and fitted directly to RBE data. Results from different experiments, different assays and both top-up and full-course fractionation techniques, can all be included in one analysis. (author)
International Nuclear Information System (INIS)
Osan, Janos; Meirer, Florian; Groma, Veronika; Toeroek, Szabina; Ingerle, Dieter; Streli, Christina; Pepponi, Giancarlo
2010-01-01
The health effects of aerosol depend on the size distribution and the chemical composition of the particles. Heavy metals of anthropogenic origin are bound to the fine aerosol fraction (PM 2.5 ). The composition and speciation of aerosol particles can be variable in time, due to the time-dependence of anthropogenic sources as well as meteorological conditions. Synchrotron-radiation total reflection X-ray fluorescence (SR-TXRF) provides very high sensitivity for characterization of atmospheric particulate matter. X-ray absorption near-edge structure (XANES) spectrometry in conjunction with TXRF detection can deliver speciation information on heavy metals in aerosol particles collected directly on the reflector surface. The suitability of TXRF-XANES for copper and zinc speciation in size-fractionated atmospheric particulate matter from a short sampling period is presented. For high size resolution analysis, atmospheric aerosol particles were collected at different urban and rural locations using a 7-stage May cascade impactor having adapted for sampling on Si wafers. The thin stripe geometry formed by the particulate matter deposited on the May-impactor plates is ideally suited to SR-TXRF. Capabilities of the combination of the May-impactor sampling and TXRF-XANES measurements at HASYLAB Beamline L to Cu and Zn speciation in size-fractionated atmospheric particulate matter are demonstrated. Information on Cu and Zn speciation could be performed for elemental concentrations as low as 140 pg/m 3 . The Cu and Zn speciation in the different size fraction was found to be very distinctive for samples of different origin. Zn and Cu chemical state typical for soils was detected only in the largest particles studied (2-4 μm fraction). The fine particles, however, contained the metals of interest in the sulfate and nitrate forms.
Faulhammer, E; Zellnitz, S; Wutscher, T; Stranzinger, S; Zimmer, A; Paudel, A
2018-01-30
This study investigates engineered carrier, as well as engineered API particles, and shows that there are distinct performance indicators of particle engineering for carrier-based dry powder inhalers (DPIs). Spray dried (SDSS) and jet-milled (JMSS) salbutamol sulphate (SS) was blended with untreated α-lactose monohydrate (LAC_R) and α-lactose monohydrate engineered (LAC_E). Subsequent capsule filling was performed with different process settings on a dosator nozzle capsule filling machine in order to reach a target fill weight of 20-25 mg. To evaluate the performance of the different mixtures, in vitro lung deposition experiments were carried out with a next generation impactor, the emitted dose (ED) and fine particle fraction (FPF) were calculated based on the specification of the European pharmacopoeia. The FPF of micronised powder blends is significantly higher (20%) compared to the FPF of spray dried blends (5%). Compared to API engineering, carrier engineering had a positive effect on the capsule filling performance (weight variability and mean fill weight) at lower compression ratios (setting 1). Results further showed that higher compression ratios appear to be beneficial in terms of capsule filling performance (higher fill weight and less fill weight variation). Concluding, it can be stated that the carrier engineering, or generally carrier properties, govern downstream processing, whereas the API engineering and API properties govern the aerosolisation performance and thereby significantly affect the dose delivery to the lungs. Copyright © 2017 Elsevier B.V. All rights reserved.
Aqrabawi, Jamal A
2006-02-15
The purpose of this prospective clinical and radiographic investigation was to assess the treatment results following endodontic therapy of teeth filled with lateral condensation versus teeth filled with vertical compaction of warm gutta-percha. A total of 290 patients were treated using the standardized step-back technique for canal preparation, which were filled with either lateral condensation or vertical compaction in one single session. Five years later, the treatment results were assessed clinically and radiographically and related to the type of the obturation technique using Chi-square analysis. Of the 340 teeth that were reexamined, 160 teeth were filled with lateral condensation, and 180 teeth were filled with vertical condensation. The results showed a significantly higher success rate for the vertical compaction versus the lateral condensation technique of teeth presented with preoperative periapical lesions P<0.04. Regardless of the preoperative periapical status of the teeth, no statistically significant difference was found between the two techniques. The overall success rate of both filling techniques was 80.3%.
DEFF Research Database (Denmark)
Hvelplund, Torben; Larsen, Mogens; Lund, Peter
2009-01-01
in different ways both chemically and physically. The starch sources were fed in mixed diets together with grass silage and soya bean meal and allocated ad libitum to fistulated dairy cows. The starch content varied between 13 and 35% in ration dry matter for the different starch sources. The design...... was a series of cross-over experiments with two cows and two periods. Ruminal starch pool was estimated from rumen evacuation and starch flow was estimated by duodenal and faeces sampling. Fractional rate of rumen degradation was estimated from the equation [kd = rumen degraded/rumen pool] and rumen and total...
Quasi-particle properties from tunneling in the v = 5/2 fractional quantum Hall state.
Radu, Iuliana P; Miller, J B; Marcus, C M; Kastner, M A; Pfeiffer, L N; West, K W
2008-05-16
Quasi-particles with fractional charge and statistics, as well as modified Coulomb interactions, exist in a two-dimensional electron system in the fractional quantum Hall (FQH) regime. Theoretical models of the FQH state at filling fraction v = 5/2 make the further prediction that the wave function can encode the interchange of two quasi-particles, making this state relevant for topological quantum computing. We show that bias-dependent tunneling across a narrow constriction at v = 5/2 exhibits temperature scaling and, from fits to the theoretical scaling form, extract values for the effective charge and the interaction parameter of the quasi-particles. Ranges of values obtained are consistent with those predicted by certain models of the 5/2 state.
Weidemann, E; Allegrini, E; Fruergaard Astrup, T; Hulgaard, T; Riber, C; Jansson, S
2016-03-01
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) formed in modern Waste-to-Energy plants are primarily found in the generated ashes and air pollution control residues, which are usually disposed of as hazardous waste. The objective of this study was to explore the occurrence of PCDD/F in different grain size fractions in the boiler ash, i.e. ash originating from the convection pass of the boiler. If a correlation between particle size and dioxin concentrations could be found, size fractionation of the ashes could reduce the total amount of hazardous waste. Boiler ash samples from ten sections of a boiler's convective part were collected over three sampling days, sieved into three different size fractions - 0.355 mm - and analysed for PCDD/F. The coarse fraction (>0.355 mm) in the first sections of the horizontal convection pass appeared to be of low toxicity with respect to dioxin content. While the total mass of the coarse fraction in this boiler was relatively small, sieving could reduce the amount of ash containing toxic PCDD/F by around 0.5 kg per tonne input waste or around 15% of the collected boiler ash from the convection pass. The mid-size fraction in this study covered a wide size range (0.09-0.355 mm) and possibly a low toxicity fraction could be identified by splitting this fraction into more narrow size ranges. The ashes exhibited uniform PCDD/F homologue patterns which suggests a stable and continuous generation of PCDD/F. Copyright © 2016 Elsevier Ltd. All rights reserved.
Process for the production of protein enriched fractions from vegetable materials
Dijkink, B.H.; Willemsen, J.H.A.
2006-01-01
The present invention provides a method for the production of a protein enriched fraction and a fibre enriched fraction from a vegetable material, wherein the vegetable material comprises a total fat content of 0.1 to 22.0 % by dry weight of the total vegetable material and a total starch content of
Testing the responses of four wheat crop models to heat stress at anthesis and grain filling.
Liu, Bing; Asseng, Senthold; Liu, Leilei; Tang, Liang; Cao, Weixing; Zhu, Yan
2016-05-01
Higher temperatures caused by future climate change will bring more frequent heat stress events and pose an increasing risk to global wheat production. Crop models have been widely used to simulate future crop productivity but are rarely tested with observed heat stress experimental datasets. Four wheat models (DSSAT-CERES-Wheat, DSSAT-Nwheat, APSIM-Wheat, and WheatGrow) were evaluated with 4 years of environment-controlled phytotron experimental datasets with two wheat cultivars under heat stress at anthesis and grain filling stages. Heat stress at anthesis reduced observed grain numbers per unit area and individual grain size, while heat stress during grain filling mainly decreased the size of the individual grains. The observed impact of heat stress on grain filling duration, total aboveground biomass, grain yield, and grain protein concentration (GPC) varied depending on cultivar and accumulated heat stress. For every unit increase of heat degree days (HDD, degree days over 30 °C), grain filling duration was reduced by 0.30-0.60%, total aboveground biomass was reduced by 0.37-0.43%, and grain yield was reduced by 1.0-1.6%, but GPC was increased by 0.50% for cv Yangmai16 and 0.80% for cv Xumai30. The tested crop simulation models could reproduce some of the observed reductions in grain filling duration, final total aboveground biomass, and grain yield, as well as the observed increase in GPC due to heat stress. Most of the crop models tended to reproduce heat stress impacts better during grain filling than at anthesis. Some of the tested models require improvements in the response to heat stress during grain filling, but all models need improvements in simulating heat stress effects on grain set during anthesis. The observed significant genetic variability in the response of wheat to heat stress needs to be considered through cultivar parameters in future simulation studies. © 2016 John Wiley & Sons Ltd.
Microhardness of bulk-fill composite materials
Kelić, Katarina; Matić, Sanja; Marović, Danijela; Klarić, Eva; Tarle, Zrinka
2016-01-01
The aim of the study was to determine microhardness of high- and low-viscosity bulk-fill composite resins and compare it with conventional composite materials. Four materials of high-viscosity were tested, including three bulk-fills: QuiXfi l (QF), x-tra fil (XTF) and Tetric EvoCeram Bulk Fill (TEBCF), while nanohybrid composite GrandioSO (GSO) served as control. The other four were low-viscosity composites, three bulk-fill materials: Smart Dentin Replacement (SDR), Venus Bulk Fill (VBF) and ...
Fractional-Order Identification and Control of Heating Processes with Non-Continuous Materials
Directory of Open Access Journals (Sweden)
Riccardo Caponetto
2016-11-01
Full Text Available The paper presents a fractional order model of a heating process and a comparison of fractional and standard PI controllers in its closed loop system. Preliminarily, an enhanced fractional order model for the heating process on non-continuous materials has been identified through a fitting algorithm on experimental data. Experimentation has been carried out on a finite length beam filled with three non-continuous materials (air, styrofoam, metal buckshots in order to identify a model in the frequency domain and to obtain a relationship between the fractional order of the heating process and the different materials’ properties. A comparison between the experimental model and the theoretical one has been performed, proving a significant enhancement of the fitting performances. Moreover the obtained modelling results confirm the fractional nature of the heating processes when diffusion occurs in non-continuous composite materials, and they show how the model’s fractional order can be used as a characteristic parameter for non-continuous materials with different composition and structure. Finally, three different kinds of controllers have been applied and compared in order to keep constant the beam temperature constant at a fixed length.
Analytic calculations of trial wave functions of the fractional quantum Hall effect on the sphere
Energy Technology Data Exchange (ETDEWEB)
Souza Batista, C.L. de [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Dingping Li [Perugia Univ. (Italy). Dipt. di Fisica
1996-07-01
We present a framework for the analytic calculations of the hierarchical wave functions and the composite fermion wave functions in the fractional quantum Hall effect on the sphere by using projective coordinates. Then we calculate the overlaps between these two wave functions at various fillings and small numbers of electrons. We find that the overlaps are most equal to one. This gives a further evidence that two theories of the fractional quantum Hall effect, the hierarchical theory, are physically equivalent. (author). 31 refs., 2 tabs.
Radiopacity of root filling materials
International Nuclear Information System (INIS)
Beyer-Olsen, E.M.
1983-01-01
A method for measuring the radiopacity of root filling materials is described. Direct measurements were made of the optic density values of the materials in comparison with a standard curve relating optic density to the thickness of an aluminium step wedge exposed simultaneously. By proper selection of film and conditions for exposure and development, it was possible to obtain a near-linear standard curve which added to the safety and reproducibility of the method. The technique of radiographic assessment was modified from clinical procedures in evaluating the obturation in radiographs, and it was aimed at detecting slits or voids between the dental wall and the filling material. This radiographic assessment of potensial leakage was compared with actual in vitro lekage of dye (basic fuchsin) into the roots of filled teeth. The result of the investigation show that root filling materials display a very wide range of radiopacity, from less than 3 mm to more than 12 mm of aluminium. It also seem that tooth roots that appear to be well obturated by radiographic evaluation, stand a good chance of beeing resistant to leakage in vitro, and that the type of filling material rather than its radiographic appearance, determines the susceptibility of the filled tooth to leakage in vitro. As an appendix the report contains a survey of radiopaque additives in root filling materials
Behavior of Hollow Thin Welded Tubes Filled with Sand Slag Concrete
Directory of Open Access Journals (Sweden)
Noureddine Ferhoune
2016-01-01
Full Text Available This paper presents the axial bearing capacity of thin welded rectangular steel stubs filled with concrete sand. A series of tests was conducted to study the behavior of short composite columns under axial compressive load; the cross section dimensions were 100 × 70 × 2 mm. A total of 20 stubs have been tested, as follows: 4 hollow thin welded tubes were tested to axial and eccentric load compression, 4 were filled with ordinary concrete appointed by BO columns, 6 were filled with concrete whose natural sand was completely substituted by a crystallized sand slag designated in this paper by BSI, and 6 were tucked in concrete whose natural sand was partially replaced by a crystallized sand slag called BSII. The main parameters studied are the height of the specimen (300 mm–500 mm, eccentricity of load and type of filling concrete. Based on test results obtained, it is confirmed that the length of the tubes has a considerable effect on the bearing capacity and the failure mode. In all test tubes, fracture occurred by the convex local buckling of steel section due to the outward thrust of the concrete; it was observed that the sand concrete improves the bearing capacity of tubes compounds compared to those filled with ordinary concrete.
Matsumoto, Kensuke; Onishi, Akira; Yamada, Hirotsugu; Kusunose, Kenya; Suto, Makiko; Hatani, Yutaka; Matsuzoe, Hiroki; Tatsumi, Kazuhiro; Tanaka, Hidekazu; Hirata, Ken-Ichi
2018-05-01
The leg-positive pressure maneuver can safely and noninvasively apply preload stress without increase in total body fluid volume. The purpose of this study was to determine whether preload stress could be useful for risk stratification of patients with heart failure with reduced ejection fraction. For this study, 120 consecutive patients with heart failure with reduced ejection fraction were prospectively recruited. The stroke work index was estimated as product of stroke volume index and mean blood pressure, and the E/e' ratio was calculated to estimate ventricular filling pressure. The echocardiographic parameters were obtained both at rest and during leg-positive pressure stress. During the median follow-up period of 20 months, 30 patients developed adverse cardiovascular events. During preload stress, stroke work index increased significantly (from 3280±1371 to 3857±1581 mm Hg·mL/m 2 ; P <0.001) along with minimal changes in ventricular filling pressure (E/e', from 16±10 to 17±9; P <0.05) in patients without cardiovascular events. However, patients with cardiovascular events showed impairment of Frank-Starling mechanism (stroke work index, from 2863±969 to 2903±1084 mm Hg·mL/m 2 ; P =0.70) and a serious increase in E/e' ratio (from 19±11 to 25±14; P <0.001). Both the patients without contractile reserve and those without diastolic reserve exhibited worse event-free survival than the others ( P <0.001). In a Cox proportional-hazards analysis, the changes in stroke work index (hazard ratio: 0.44 per 500 mm Hg·mL/m 2 increase; P =0.001) and in E/e' (hazard ratio: 2.58 per 5-U increase; P <0.001) were predictors of cardiovascular events. Contractile reserve and diastolic reserve during leg-positive pressure stress are important determinants of cardiovascular outcomes for patients with heart failure with reduced ejection fraction. © 2018 American Heart Association, Inc.
Estimation of water-filled and air-filled porosity in the unsaturated zone, Yucca Mountain, Nevada
International Nuclear Information System (INIS)
Nelson, P.H.
1993-01-01
Water content and porosity vary considerably within the unsaturated zone at Yucca Mountain. Measurement of these quantities has been based on core samples. A log-based approach offers the advantage of in-situ measurements, continuous throughout the borehole. This paper describes an algorithm which determines the air-filled and water-filled porosities from density and dielectric logs. The responses of density and dielectric logs are formulated in terms of the matrix properties, air-filled porosity and water-filled porosity. Porosity values obtained from logs from borehole USW G-2 are in reasonable agreement with estimates from core determinations
International Nuclear Information System (INIS)
Pellegrini, C.A.; Ryan, T.; Broderick, W.; Way, L.W.
1986-01-01
We studied gallbladder bile flow before, during, and after cholesterol gallstone formation in the prairie dog using infusion cholescintigraphy with /sup 99m/Tc-diethyl iminodiacetic acid. In 18 fasting animals partitioning of bile between gallbladder and intestine was determined every 15 min for 140 min, and gallbladder response to cholecystokinin (5 U/kg X h) was calculated from the gallbladder ejection fraction. Ten prairie dogs were then placed on a 0.4% cholesterol diet and 8 on a regular diet, and the studies were repeated 1, 2, and 6 wk later. The proportion of hepatic bile that entered the gallbladder relative to the intestine varied from one 15-min period to the next, and averaged 28.2% +/- 5.1% at 140 min. Partial spontaneous gallbladder emptying (ejection fraction 11.5% +/- 5.6%) was intermittently observed. Neither the number nor the ejection fraction of spontaneous gallbladder contractions changed during gallstone formation. By contrast, the percent of gallbladder emptying in response to cholecystokinin decreased from 72.1% +/- 5% to 25.9% +/- 9.3% (p less than 0.025) in the first week and was 14.3% +/- 5.5% at 6 wk (p less than 0.01 from prediet values, not significant from first week). Gallbladder filling decreased from 28.2% +/- 5.1% to 6.7% +/- 3% (p less than 0.01), but this change was only observed after 6 wk, when gallstones had formed. This study shows that bile flow into the gallbladder during fasting is not constant; the gallbladder contracts intermittently; gallbladder emptying in response to exogenous cholecystokinin is altered very early during gallstone formation; and gallbladder filling remains unaffected until later stages, when gallstones have formed
The Particle Distribution in Liquid Metal with Ceramic Particles Mould Filling Process
Dong, Qi; Xing, Shu-ming
2017-09-01
Adding ceramic particles in the plate hammer is an effective method to increase the wear resistance of the hammer. The liquid phase method is based on the “with the flow of mixed liquid forging composite preparation of ZTA ceramic particle reinforced high chromium cast iron hammer. Preparation method for this system is using CFD simulation analysis the particles distribution of flow mixing and filling process. Taking the 30% volume fraction of ZTA ceramic composite of high chromium cast iron hammer as example, by changing the speed of liquid metal viscosity to control and make reasonable predictions of particles distribution before solidification.
Utilization of crushed radioactive concrete for mortar to fill waste container void space
International Nuclear Information System (INIS)
Ishikura, Takeshi; Ohnishi, Kazuhiko; Oguri, Daiichiro; Ueki, Hiroyuki
2004-01-01
Minimizing the volume of radioactive waste generated during dismantling of nuclear power plants is a matter of great importance. In Japan waste forms buried in a shallow burial disposal facility as low level radioactive waste must be solidified by cement or other materials with adequate strength and must provide no harmful opening. The authors have developed an improved method to minimize radioactive waste volume by utilizing radioactive concrete for fine aggregate for mortars to fill void space in waste containers. Tests were performed with pre-placed concrete waste and with filling mortar using recycled fine aggregate produced from concrete. It was estimated that the improved method substantially increases the waste fill ratio in waste containers, thereby decreasing the total volume of disposal waste. (author)
Mechanics of filled carbon nanotubes
Monteiro, A.O.; Cachim, P.B.; Da Costa, Pedro M. F. J.
2014-01-01
The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.
Mechanics of filled carbon nanotubes
Monteiro, A.O.
2014-04-01
The benefits of filling carbon nanotubes (CNTs) with assorted molecular and crystalline substances have been investigated for the past two decades. Amongst the study of new structural phases, defects, chemical reactions and varied types of host-guest interactions, there is one fundamental characterisation aspect of these systems that continues to be overlooked: the mechanical behaviour of filled CNTs. In contrast to their empty counterparts, the mechanics of filled CNTs is a subject where reports appear far and apart, this despite being key to the application of these materials in technological devices. In the following paragraphs, we review the work that has been carried out up to the present on the mechanics of filled CNTs. The studies discussed range from experimental resonant frequency essays performed within electron microscopes to modelling, via molecular dynamics, of three-point bending of nanotubes filled with gases. (C) 2014 Elsevier B.V. All rights reserved.
Torrent-Guasp, Francisco; Kocica, Mladen J; Corno, Antonio; Komeda, Masashi; Cox, James; Flotats, A; Ballester-Rodes, Manel; Carreras-Costa, Francesc
2004-03-01
The evidence of the ventricular myocardial band (VMB) has revealed unavoidable coherence and mutual coupling of form and function in the ventricular myocardium, making it possible to understand the principles governing electrical, mechanical and energetical events within the human heart. From the earliest Erasistratus' observations, principal mechanisms responsible for the ventricular filling have still remained obscured. Contemporary experimental and clinical investigations unequivocally support the attitude that only powerful suction force, developed by the normal ventricles, would be able to produce an efficient filling of the ventricular cavities. The true origin and the precise time frame for generating such force are still controversial. Elastic recoil and muscular contraction were the most commonly mentioned, but yet, still not clearly explained mechanisms involved in the ventricular suction. Classical concepts about timing of successive mechanical events during the cardiac cycle, also do not offer understandable insight into the mechanism of the ventricular filling. The net result is the current state of insufficient knowledge of systolic and particularly diastolic function of normal and diseased heart. Here we summarize experimental evidence and theoretical backgrounds, which could be useful in understanding the phenomenon of the ventricular filling. Anatomy of the VMB, and recent proofs for its segmental electrical and mechanical activation, undoubtedly indicates that ventricular filling is the consequence of an active muscular contraction. Contraction of the ascendent segment of the VMB, with simultaneous shortening and rectifying of its fibers, produces the paradoxical increase of the ventricular volume and lengthening of its long axis. Specific spatial arrangement of the ascendent segment fibers, their interaction with adjacent descendent segment fibers, elastic elements and intra-cavitary blood volume (hemoskeleton), explain the physical principles
Çekiç, Sema Demirci; Demir, Aslı; Başkan, Kevser Sözgen; Tütem, Esma; Apak, Reşat
2015-05-01
Most milk-applied antioxidant assays in literature are based on the isolation and quantification of individual antioxidative compounds, whereas total antioxidant capacity (TAC) gives a more holistic picture due to cooperative action of antioxidants. Recently, the cupric reducing antioxidant capacity (CUPRAC) method has been modified to measure the antioxidant capacities of thiol-containing proteins, where the classical ammonium acetate buffer - that may otherwise precipitate proteins- was replaced with concentrated urea buffer (able to expose embedded thiol groups of proteins to oxidative attack) adjusted to pH 7.0. Thus, antioxidant capacity of milk was investigated with two competing TAC assays, namely CUPRAC and ABTS (2,2'-azinobis(3-ethylbenzothiazoline-6-sulphonic acid))/persulphate, because only these assays were capable of evaluating protein contribution to the observed TAC value. As milk fat caused turbidity, experiments were carried out with skim milk or defatted milk samples. To determine TAC, modified CUPRAC method was applied to whole milk, separated and redissolved protein fractions, and the remaining liquid phase after necessary operations. Both TAC methods were investigated for their dilution sensitivity and antioxidant power assessment of separate milk fractions such as casein and whey. Proteins like β-lactoglobulin and casein (but not simple thiols) exhibited enhanced CUPRAC reactivity with surfactant (SDS) addition. Addition of milk protein fractions to whole skim milk produced significant 'negative-biased' deviations (up to -26% relative standard error) from TAC absorbance additivity in the application of the ABTS method, as opposed to that of the CUPRAC method less affected by chemical deviations from Beer's law thereby producing much smaller deviations from additivity (i.e. the property of additivity is valid when the measured TAC of a mixture is equal to the sum of individual antioxidant capacities of its constituents).
Alkhudhairy, Fahad I.
2018-01-01
Objectives: To evaluate the surface roughness of 4 different bulk-fill resin-based composites cured using different irradiance levels. Methods: This in vitro study was performed in February 2017 to August 2017 at the College of Dentistry, King Saud University. Twenty-four specimens were prepared from each of the bulk-fill materials [Tetric N-Ceram (TNC), SonicFill (SF), Smart Dentin Replacement (SDR), and Filtek Bulk-Fill (FB)] using a brass metal mold, resulting in a total of 96 specimens, cured using a Bluephase N light curing unit. Half of the total number of specimens (N=48) were cured using high-power irradiance (1200 mW/cm2) for 20 seconds, while the remaining half (N=48) were cured using low power irradiance (650 mW/cm2) for 40 seconds. After 24 hours, baseline surface roughness of each specimen was analyzed using a profilometer, then polished using Sof-lex abrasive disks, and the surface roughness of all groups was assessed. Results: Post-polished SonicFill cured at high irradiance had the highest mean surface roughness (0.23±0.03), whereas pre-polished Smart Dentin Replacement (0.11±0.01) and SonicFill (0.11±0.02) cured at low irradiance had the lowest mean surface roughness. Conclusion: High curing irradiance (1,200 mW/cm2) had no positive influence on the surface roughness of Filtek Bulk Fill and Tetric N-Ceram bulk-fill RBCs compared with lower curing irradiance (650 mW/cm2). However, the difference of curing irradiance significantly affected the surface roughness in SDR and sonic fill RBCs. PMID:29436570
Vertical Scan-Conversion for Filling Purposes
Hersch, R. D.
1988-01-01
Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...
Pohl, Pawel; Stelmach, Ewelina; Szymczycha-Madeja, Anna
2014-11-15
A simpler, and faster than wet digestion, sample treatment was proposed prior to determination of total concentrations for selected macro- (Ca, Mg) and microelements (Fe, Mn) in soluble coffees by flame atomic absorption spectrometry. Samples were dissolved in water and acidified with HNO3. Precision was in the range 1-4% and accuracy was better than 2.5%. The method was used in analysis of 18 soluble coffees available on the Polish market. Chemical fractionation patterns for Ca, Fe, Mg and Mn in soluble coffees, as consumed, using a two-column solid-phase extraction method, determined Ca, Mg and Mn were present predominantly as cations (80-93% of total content). This suggests these elements are likely to be highly bioaccessible. Copyright © 2014 Elsevier Ltd. All rights reserved.
The role of localization within the vortex picture of the fractional quantum Hall effect
International Nuclear Information System (INIS)
Bruus, H.; Hansen, O.P.; Hansen, E.B.
1988-01-01
Plateau formation in the fractional quantum Hall effect is shown to arise because, by pinning of vortices in the incompressible electron liquid, the canonical filling factor can be stationarily maintained in the interconnected region between the vortices. The crucial role of localization is demonstrated by considering the idealized limit where pinning centres are absent. (orig.)
Summability calculus a comprehensive theory of fractional finite sums
Alabdulmohsin, Ibrahim M
2018-01-01
This book develops the foundations of "summability calculus", which is a comprehensive theory of fractional finite sums. It fills an important gap in the literature by unifying and extending disparate historical results. It also presents new material that has not been published before. Importantly, it shows how the study of fractional finite sums benefits from and contributes to many areas of mathematics, such as divergent series, numerical integration, approximation theory, asymptotic methods, special functions, series acceleration, Fourier analysis, the calculus of finite differences, and information theory. As such, it appeals to a wide audience of mathematicians whose interests include the study of special functions, summability theory, analytic number theory, series and sequences, approximation theory, asymptotic expansions, or numerical methods. Richly illustrated, it features chapter summaries, and includes numerous examples and exercises. The content is mostly developed from scratch using only undergr...
Matijević, Jurica; Čižmeković Dadić, Tina; Prpić Mehičić, Goranka; Anić, Ivica; Šlaj, Mladen; Jukić Krmek, Silvana
2011-01-01
Aim To determine the prevalence of apical periodontitis and assess the quality of endodontic fillings in the population of the city of Zagreb, Croatia. Methods A total of 1462 orthopantomograms from new patients at 6 different dental practices was analyzed during 2006 and 2007. The presence of periapical lesions was determined by using the periapical index score (PAI). The quality of endodontic fillings was assessed according to the filling length and homogeinicity. Data were analyzed using t test and ANOVA with Scheffe post-hoc test. Results There were 75.9% of participants with endodontically treated teeth and 8.5% of all teeth were endodontically treated. Only 34.2% of endodontically treated roots had adequate root canal filling length, while 36.2% of root canal fillings had homogenous appearance. From the total number of teeth with intracanal post, 17.5% had no visible root canal filling. Using PAI 3 as a threshold value for apical periodontitis, periapical lesions were detected in 8.5% of teeth. Adequate quality of root canal fillings was associated with a lower prevalence of periapical lesions. Conclusion We found a large proportion of endodontically treated teeth with apical periodontitis and a correlation between the quality of endodontic filling and the prevalence of periapical lesions. This all suggests that it is necessary to improve the quality of endodontic treatment in order to reduce the incidence and prevalence of apical periodontitis. PMID:22180266
Removal of root filling materials.
LENUS (Irish Health Repository)
Duncan, H.F. Chong, B.S.
2011-05-01
Safe, successful and effective removal of root filling materials is an integral component of non-surgical root canal re-treatment. Access to the root canal system must be achieved in order to negotiate to the canal terminus so that deficiencies in the original treatment can be rectified. Since a range of materials have been advocated for filling root canals, different techniques are required for their removal. The management of commonly encountered root filling materials during non-surgical re-treatment, including the clinical procedures necessary for removal and the associated risks, are reviewed. As gutta-percha is the most widely used and accepted root filling material, there is a greater emphasis on its removal in this review.
The Fractionation and Enrichment of La Content by Precipitation
International Nuclear Information System (INIS)
Suyanti; Purwani, MV
2007-01-01
The fractionation and enrichment of La content by precipitation have been done. The feed was La hydroxide by product of monazite sand. La hydroxide was diluted in HNO 3 and was precipitated with ammonia. For to obtain La, diluent was precipitated at pH 8 and the filtrate was precipitated with oxalic acid. The precipitant of La concentrated was more rich than the feed. This process was done continue and fractionally. The best yield of enrichment of La was obtained at dilution of 25 gram La Hydroxide in 20 ml HNO 3 . The efficient degree of fractionation was XV. The average weight of La concentrate was obtained at every fraction was 1 gram. The total sum weight from fraction I until fraction XV 13.5 grams. The average of La content was 48%, average fractionation efficiency of La for every step of fractionation was 48 %. Total efficiency all process was 100%. The average ratio of La/Nd was 2 and the ratio of La/Ce almost infinite. Before processed La/Ce was 7.86, and after process increase to 26.92 - to approach ∞. Before processed ratio of La/Nd was 2.79, after processed increased to 4.4 - to approach ∞. (author)
Chemical composition of material fractions in Danish household waste
DEFF Research Database (Denmark)
Riber, Christian; Petersen, Claus; Christensen, Thomas Højlund
2009-01-01
batches of 80-1200 tonnes of unsorted household waste was incinerated and the content of the waste determined from the content of the outputs from the incinerator. The indirect method is believed to better represent the small but highly contaminated material fractions (e,g., batteries) than the direct...... like paper, cardboard anti organic fractions. The single fraction contributing most to the total energy content is the non-recyclable plastic fraction, contributing 21% of the energy content and 60% of the chlorine content, although this fraction comprises less than 7% by weight. Heavy metals originate...... mainly from inert fractions, primarily batteries....
Phase Diagram of a Simple Model for Fractional Topological Insulator
Chen, Hua; Yang, Kun
2012-02-01
We study a simple model of two species of (or spin-1/2) fermions with short-range intra-species repulsion in the presence of opposite (effetive) magnetic field, each at filling factor 1/3. In the absence of inter-species interaction, the ground state is simply two copies of the 1/3 Laughlin state, with opposite chirality. Due to the overall time-reversal symmetry, this is a fractional topological insulator. We show this phase is stable against moderate inter-species interactions. However strong enough inter-species repulsion leads to phase separation, while strong enough inter-species attraction drives the system into a superfluid phase. We obtain the phase diagram through exact diagonalization caluclations. Nature of the fractional topological insluator-superfluid phase transition is discussed using an appropriate Chern-Simons-Ginsburg-Landau effective field theory.
Morphological correlates of fractionated radiation of the mouse lung: Early and late effects
International Nuclear Information System (INIS)
Penney, D.P.; Siemann, D.W.; Rubin, P.; Maltby, K.
1994-01-01
The definition and quantitation of radiation-induced morphologic alterations in murine lungs is presented. The extent of injury to the lung, which is the dose-limiting organ in the thorax, may be reduced by fractionating the total radiation exposure to permit partial repair of radiation-induced damage between fraction administration and also to permit a larger total exposure to be administered. The authors previously reported that, following fractionated radiation exposures, as the dose/fraction decreases, the total dose to reach an isoeffect increases, with an α/β ratio of 3.2 and 3.0 for breathing rates and lethality, respectively. In the present report, they provide comparative morphologic evaluation of the effects of weekly fractionated, daily fractionated, and hyperfractionated radiation exposures. The doses administered within each group were uniform. To determine morphologic alterations, LAF1 mice were irradiated with 3, 15, and 30 fractions delivered in 19 days overall treatment time. In the hyperfractionation schedule, the two fractions per day were separated by a 6-h time interval. Total doses were as follows: 15-21 Gy for weekly fractionation, 30-41.5 Gy for daily fractionation, and 30-49.5 Gy for hyperfractionated schedules. Lung tissue, recovered either 24 or 72 weeks following the final exposure, was evaluated by transmission and scanning electron microscopy and light microscopy. Morphological damage was not uniform throughout the exposed lung and tended to be concentrated in lobes or portions of lobes. In the three fractionation regimens studied, there is progressive sparing of the lung with increased fractionation during the pnuemonitic state (24 weeks postirradiation). Both daily and twice daily fractionations provide increased sparing over weekly fractionation during the fibrotic stages (72 weeks postirradiation), but were not markedly different from each other (i.e. weekly < daily = twice daily). 41 refs., 15 figs., 2 tabs
Abd-El-Aziz, Tarek A
2012-01-01
The aim of this study was to compare 3 different available methods for estimating left ventricular end-diastolic pressure (LVEDP) noninvasively in patients with coronary artery disease and preserved left ventricular ejection fraction (EF). We used 3 equations for noninvasive estimation of LVEDP: The equation of Mulvagh et al., LVEDP(1) = 46 - 0.22 (IVRT) - 0.10 (AFF) - 0.03 (DT) - (2 ÷ E/A) + 0.05 MAR; the equation of Stork et al., LVEDP(2) = 1.06 + 15.15 × Ai/Ei; and the equation of Abd-El-Aziz, LVEDP(3) = [0.54 (MABP) × (1 - EF)] - 2.23. ( A, A-wave velocity; AFF, atrial filling fraction; Ai, time velocity integral of A wave; DT, deceleration time; E, E-wave velocity; Ei, time velocity integral of E wave; IVRT, isovolumic relaxation time; MABP, mean arterial blood pressure; MAR, time from termination of mitral flow to the electrocardiographic R wave; Ti, time velocity integral of total wave.) LVEDP measured by catheterization was correlated with LVEDP(1) (r = 0.52, P Aziz, LVEDP = [0.54 MABP × (1 - EF)] - 2.23, appears to be the most accurate, reliable, and easily applied method for estimating LVEDP noninvasively in patients with preserved left ventricular ejection fraction and an LVEDP < 20 mm Hg. Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
An Evaluation of GuttaFlow2 in Filling Artificial Internal Resorption Cavities: An in vitro Study.
Mohammad, Yara; Alafif, Hisham; Hajeer, Mohammad; Yassin, Oula
2016-06-01
Obturation of root canal with internal resorption represents a major challenge in Endodontics. In spite of that, usual obturation techniques are often employed without considering the best technique to solve this problem. The goal of this study was to investigate the ability of GuttaFlow2 in filling artificial internal resorption cavities. The study sample included 36 human upper central incisors that were prepared using Protaper system (F4). Internal resorption cavities were prepared by cutting each tooth at 7 mm from the apex and preparing hemispherical cavities on both the sides and then re-attaching them. The sample was randomly separated into three groups (n = 12 in each group). In the first group, thermal injection technique (Obtura II) was employed and served as the control group. In the second group, injection of cold free-flow obturation technique with a master cone (GF2-C) was employed, whereas in the third group injection of cold free-flow obturation without a master cone (GF2) was followed. The teeth were re-cut at the same level as before and examined under a stereomicroscope. Subsequently, the captured images were transferred to AutoCAD program to measure the percentage of total filling "TF," gutta-percha "G," sealer "S," and voids "V" out of the total surface of the cross sections. All materials showed high filling properties in terms of "total filling," ranging from 99.17% (for Obtura II) to 99.72% (for GF2-C). Regarding gutta-percha percentages of filling, they ranged from 83.15 to 83.93%, whereas those for the sealer ranged from 5.71 to 15.24%. GuttaFlow2 group with a master cone appeared to give the best results despite the insignificant differences among the three groups. The GuttaFlow2 with a master cone technique seemed to be a promising filling material and gave results similar to those observed with Obtura II. It is recommended for use to obturate internal resorption cavities in clinical practice due to its good adaptability to root canal
Phosphorus fractions, microbial biomass and enzyme activities in ...
African Journals Online (AJOL)
Potohar, northern Punjab, Pakistan in September, 2008 and analysed for P fractions and microbial parameters including microbial biomass C, microbial biomass N, microbial biomass P, and activities of dehydrogenase and alkaline phosphatase enzymes. The average size of different P fractions (% of total P) in the soils ...
Chowdhury, Md Albarune; de Neergaard, Andreas; Jensen, Lars Stoumann
2014-01-01
Solid-liquid separation of animal slurry, with solid fractions used for composting, has gained interest recently. However, efficient composting of separated animal slurry solid fractions (SSFs) requires a better understanding of the process dynamics in terms of important physical parameters and their interacting physical relationships in the composting matrix. Here we monitored moisture content, bulk density, particle density and air-filled porosity (AFP) during composting of SSF collected from four commercially available solid-liquid separators. Composting was performed in laboratory-scale reactors for 30 days (d) under forced aeration and measurements were conducted on the solid samples at the beginning of composting and at 10-d intervals during composting. The results suggest that differences in initial physical properties of SSF influence the development of compost maximum temperatures (40-70 degreeC). Depending on SSF, total wet mass and volume losses (expressed as % of initial value) were up to 37% and 34%, respectively. After 30 d of composting, relative losses of total solids varied from 17.9% to 21.7% and of volatile solids (VS) from 21.3% to 27.5%, depending on SSF. VS losses in all composts showed different dynamics as described by the first-order kinetic equation. The estimated component particle density of 1441 kg m-3 for VS and 2625 kg m-3 for fixed solids can be used to improve estimates of AFP for SSF within the range tested. The linear relationship between wet bulk density and AFP reported by previous researchers held true for SSF.
Directory of Open Access Journals (Sweden)
Jean Sérgio Rosset
2014-10-01
Full Text Available Mechanized harvesting maintenance of trash from cane sugar and soil application of waste as vinasse and filter cake can improve the system of crop yield. Thus, this study aimed to evaluate the changes in the chemical, the stock of total organic carbon and humified organic matter fractions in an Oxisol cultivated with cane sugar with the following management systems: with sugarcane vinasse application (CCV, without application of burnt cane waste (CQS, with burnt cane vinasse application (CQV, with application of burnt cane filter cake (CQTF and burnt cane with joint application of vinasse and filter cake (CQVTF. For reference we used an area of natural vegetation (NV, Cerrado sensu stricto. Treatment CQVTF showed improvement in soil chemical properties, increased inventory levels of total organic carbon – TOC (values ranging from 21.28 to 40.02 Mg ha-1 and humified fractions of soil organic matter in relation to other treatments. The CQS area at a depth of 0-0.05 m, showed the greatest losses of soil TOC stocks (56.3% compared to NV. The adoption of management presented CCV and chemical attributes of the soil TOC stocks equivalent to those observed in areas with CQV CQTF and despite the short period of adoption (3 years. The TOC correlated with the sum of bases (r = 0.76 **, cation exchange capacity (r = 0.59 ** and base saturation (r = 0.63 **, while the humic acids (r = 0.40 ** fulvic acids (r = 0.49 ** and humin (r = 0.59 ** correlated with the cation exchange capacity of the soil. These results indicate that the preservation of trash in the management of cane sugar added to the application of vinasse and filter cake increases the TOC stocks promoting improvement in soil chemical properties.
Gas-filled hohlraum fabrication
International Nuclear Information System (INIS)
Salazar, M.A.; Gobby, P.L.; Foreman, L.R.; Bush, H. Jr.; Gomez, V.M.; Moore, J.E.; Stone, G.F.
1995-01-01
Los Alamos National Laboratory (LANL) researchers have fabricated and fielded gas-filled hohlraums at the Lawrence Livermore National Laboratory (LLNL) Nova laser. Fill pressures of 1--5 atmospheres have been typical. We describe the production of the parts, their assembly and fielding. Emphasis is placed on the production of gas-tight polyimide windows and the fielding apparatus and procedure
NSLS-II filling pattern measurement
International Nuclear Information System (INIS)
Yong Hu; Dalesio, L.B.; Kiman Ha; Pinayev, I.
2012-01-01
Multi-bunch injection will be deployed at NSLS-II. High bandwidth diagnostic beam monitors with high speed digitizers are used to measure bunch-by-bunch charge variation. In order to minimize intensity-correlated orbit oscillations due to uneven bunch patterns, we need to measure the filling pattern (also named bunch pattern or bunch structure). This paper focuses on filling pattern measurements: how to measure bunch structure and make this information available in EPICS-based control system. This measurement requires combination of 3 types of beam monitors (Wall Current Monitor, Fast Current Transformer and Beam Position Monitor), data acquisition and controls (fast digitizer, EPICS software, etc.) and Event Timing system. High-bandwidth filling pattern monitor requires high-speed digitizer to sample its analog output signal. The evaluation results of commercial fast digitizer Agilent Acqiris and high bandwidth detector Bergoz FCT are presented. We have also tested the algorithm software for filling pattern measurement as well as the interface to event timing system. It appears that filling pattern measurement system is well understood and the tests for control hardware and software have given good results
Vyrides, Ioannis; Drakou, Efi-Maria; Ioannou, Stavros; Michael, Fotoula; Gatidou, Georgia; Stasinakis, Athanasios S
2018-07-01
The bilge water that is stored at the bottom of the ships is saline and greasy wastewater with a high Chemical Oxygen Demand (COD) fluctuations (2-12 g COD L -1 ). The aim of this study was to examine at a laboratory scale the biodegradation of bilge water using first anaerobic granular sludge followed by aerobic microbial consortium (consisted of 5 strains) and vice versa and then based on this to implement a pilot scale study. Batch results showed that granular sludge and aerobic consortium can remove up to 28% of COD in 13 days and 65% of COD removal in 4 days, respectively. The post treatment of anaerobic and aerobic effluent with aerobic consortium and granular sludge resulted in further 35% and 5% COD removal, respectively. The addition of glycine betaine or nitrates to the aerobic consortium did not enhance significantly its ability to remove COD from bilge water. The aerobic microbial consortium was inoculated in 3 pilot (200 L) Moving Bed Biofilm Reactors (MBBRs) under filling fractions of 10%, 20% and 40% and treated real bilge water for 165 days under 36 h HRT. The MBBR with a filling fraction of 40% resulted in the highest COD decrease (60%) compared to the operation of the MBBRs with a filling fraction of 10% and 20%. GC-MS analysis on 165 day pointed out the main organic compounds presence in the influent and in the MBBR (10% filling fraction) effluent. Copyright © 2018 Elsevier Ltd. All rights reserved.
Review of fill mining technology in Canada
Energy Technology Data Exchange (ETDEWEB)
Singh, K. H.; Hedley, D. G.F.
1980-05-15
The Canadian mining industry has a long history of being in the fore-front in developing new technology in underground hardrock mines. Examples include the development of hydraulic and cemented fills, undercut-and-fill, mechanized cut-and-fill, post pillar, vertical retreat and blasthole mining methods. The evolution of this technology is briefly described in an historical review. Backfill serves many functions, although it is generally considered in terms of its support capabilities. These functions, mainly related to the mining method used, are evaluated in regard to regional support, pillar support, fill roof, working floor, dilution control and waste disposal. With the advent of blasthole and vertical retreat methods for pillar recovery operations, the freestanding height of backfill walls has assumed greater importance. Consequently, more attention is being given to what fill properties are required to achieve fill wall exposures up to 25 m wide by 90 m high. With the large increases in energy costs, alternatives to partially replace Portland cement in fill are being examined. The validation of mining concepts and the interaction of backfill is perhaps best evaluated by in-situ measurements. Examples are given of stress, deformation and fill pressure measurements in longitudinal cut-and-fill, post pillar mining and blasthole stoping with delayed fill which were taken in several mines in Canada. Finally, the overall design procedure used in deciding mining method, stope and pillar dimensions, sequence of extraction, fill properties and support systems at a new mine is described.
Text-Filled Stacked Area Graphs
DEFF Research Database (Denmark)
Kraus, Martin
2011-01-01
-filled stacked area graphs; i.e., graphs that feature stacked areas that are filled with small-typed text. Since these graphs allow for computing the text layout automatically, it is possible to include large amounts of textual detail with very little effort. We discuss the most important challenges and some...... solutions for the design of text-filled stacked area graphs with the help of an exemplary visualization of the genres, publication years, and titles of a database of several thousand PC games....
Fractal systems of central places based on intermittency of space-filling
International Nuclear Information System (INIS)
Chen Yanguang
2011-01-01
Highlights: → The idea of intermittency is introduced into central place model. → The revised central place model suggests incomplete space filling. → New central place fractals are presented for urban analysis. → The average nearest distance is proposed to estimate the fractal dimension. → The concept of distance-based space is replaced by that of dimension-based space. - Abstract: The central place models are fundamentally important in theoretical geography and city planning theory. The texture and structure of central place networks have been demonstrated to be self-similar in both theoretical and empirical studies. However, the underlying rationale of central place fractals in the real world has not yet been revealed so far. This paper is devoted to illustrating the mechanisms by which the fractal patterns can be generated from central place systems. The structural dimension of the traditional central place models is d = 2 indicating no intermittency in the spatial distribution of human settlements. This dimension value is inconsistent with empirical observations. Substituting the complete space filling with the incomplete space filling, we can obtain central place models with fractional dimension D < d = 2 indicative of spatial intermittency. Thus the conventional central place models are converted into fractal central place models. If we further integrate the chance factors into the improved central place fractals, the theory will be able to explain the real patterns of urban places very well. As empirical analyses, the US cities and towns are employed to verify the fractal-based models of central places.
Moorthy, A; Hogg, C H; Dowling, A H; Grufferty, B F; Benetti, A R; Fleming, G J P
2012-06-01
To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases. Twenty-four sound upper premolar teeth with Class II cavities were allocated to three groups (n=8). Restoration of the teeth involved the placement of an RBC (GrandioSO) in eight oblique increments (Group A) or Groups B and C were restored to within 2 mm of the palatal cusp in a single increment with bulk-fill flowable RBC bases (SDR and x-tra base) before the two occlusal cavity increments were placed with GrandioSO. Buccal and palatal cusp deflections were recorded postirradiation using a twin channel deflection measuring gauge. Following restoration, the teeth were thermocycled, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage. The mean total cuspal deflection for the oblique incremental restoration technique was 11.26 (2.56) μm (Group A) and 4.63 (1.19) μm (Group B) and 4.73 (0.99) μm (Group C) for the bulk-fill flowable RBC bases. A significant increase in the mean total cuspal deflection for the incrementally filled GrandioSO compared with the SDR (P=0.007) and x-tra base (P=0.005) restored teeth was evident. No significant difference in the cervical microleakage scores was recorded between groups AC (P>0.05). The bulk-fill flowable RBC bases significantly reduced cuspal deflection compared with a conventional RBC restored in an oblique incremental filling technique with no associated change in cervical microleakage recorded. Copyright © 2012 Elsevier Ltd. All rights reserved.
Field configurations for small deviations of the integral filling factors in IQHE
International Nuclear Information System (INIS)
Cabo, A.; Castineiras, J.; Gonzalez, R.; Penaranda, S.
1990-07-01
A numerical solution of the effective Maxwell equations of the IQHE is presented. It corresponds to inhomogeneous electromagnetic field distributions appearing after a small constant magnetic field is added to a 2D-electron gas sheet when the density exactly fills an integral number of Landau levels. It follows that the Chern-Simons terms of the Maxwell equation transform the applied magnetic field into an equivalent homogeneous charge density. The numerical value of this density is exactly the one which is needed to furnish complete filling at the new value of the total magnetic field. The system then reacts tending to screen the effective charge density by removing charge from the sample edges. It is interesting that for the selected parameter values here, reflecting the current experimental situations, the system response is able to approximately establish an integral filling factor in the central portion of the sheet. Then, at least a small plateau is predicted to occur in pure samples at zero temperature. It also follows that the current distribution is unsymmetric under the inversion, as opposed to the configuration associated to a flow of a net Hall current at integral filling factors. (author). 8 refs, 4 figs
Shear bond strength of bulk-fill and nano-restorative materials to dentin.
Colak, Hakan; Ercan, Ertugrul; Hamidi, Mehmet Mustafa
2016-01-01
Bulk-fill composite materials are being developed for preparation depths of up to 4 mm in an effort to simplify and improve the placement of direct composite posterior restorations. The aim of our study was to compare shear-bond strength of bulk-fill and conventional posterior composite resins. In this study, 60 caries free extracted human molars were used and sectioned parallel to occlusal surface to expose midcoronal dentin. The specimens were randomly divided into four groups. Total-etch dentine bonding system (Adper Scotchbond 1XT, 3M ESPE) was applied to dentin surface in all the groups to reduce variability in results. Then, dentine surfaces covered by following materials. Group I: SonicFill Bulk-Fill, Group II: Tetric EvoCeram (TBF), Group III: Herculite XRV Ultra, and Group IV: TBF Bulk-Fill, 2 mm × 3 mm cylindrical restorations were prepared by using application apparatus. Shear bond testing was measured by using a universal testing machine. Kruskal-Wallis and Mann-Whitney U-tests were performed to evaluate the data. The highest value was observed in Group III (14.42 ± 4.34) and the lowest value was observed in Group IV (11.16 ± 2.76) and there is a statistically significant difference between these groups (P = 0.046). However, there is no statistically significant difference between the values of other groups. In this study, Group III was showed higher strength values. There is a need for future studies about long-term bond strength and clinical success of these adhesive and bulk-fill systems.
Larsen, Christian; Thorstenson, Anders
2006-01-01
The order fill rate is less commonly used than the volume fill rate (most often just denoted fill rate) as a performance measure for inventory control systems. However, in settings where the focus is on filling customer orders rather than total quantities, the order fill rate should be the preferred measure. In this paper we consider a continuous review, base-stock policy, where all replenishment orders have the same constant lead time and all unfilled demands are backordered. We develop exac...
7 CFR 58.923 - Filling containers.
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.923 Section 58.923 Agriculture... Procedures § 58.923 Filling containers. (a) The filling of small containers with product shall be done in a sanitary manner. The containers shall not contaminate or detract from the quality of the product in any way...
Fractionation for Biodiesel Purification Using Supercritical Carbon Dioxide
Directory of Open Access Journals (Sweden)
Chao-Yi Wei
2014-02-01
Full Text Available In recent years, biodegradable and alternative biodiesel has attracted increased attention worldwide. Producing biodiesel from biomass involves critical separation and purification technology. Conventional technologies such as gravitational settling, decantation, filtration, water washing, acid washing, organic solvent washing and absorbent applications are inefficient, less cost effective and environmentally less friendly. In this study supercritical carbon dioxide (SC-CO2 with few steps and a low environmental impact, was used for biodiesel fractionation from impure fatty acid methyl ester (FAME solution mixes. The method is suitable for application in a variety of biodiesel production processes requiring subsequent stages of purification. The fractionation and purification was carried out using continuous SC-CO2 fractionation equipment, consisting of three columns filled with stainless steel fragments. A 41.85% FAME content solution mix was used as the raw material in this study. Variables were a temperature range of 40–70 °C, pressure range of 10–30 MPa, SC-CO2 flow rate range of 7–21 mL/min and a retention time range of 30–90 min. The Taguchi method was used to identify optimal operating conditions. The results show that a separated FAME content of 99.94% was verified by GC-FID under optimal fractionation conditions, which are a temperature of 40 °C of, a pressure level of 30MPa and a flow rate of 7 mL/min of SC-CO2 for a retention time of 90 min.
Raman spectra of filled carbon nanotubes
International Nuclear Information System (INIS)
Bose, S.M.; Behera, S.N.; Sarangi, S.N.; Entel, P.
2004-01-01
The Raman spectra of a metallic carbon nanotube filled with atoms or molecules have been investigated theoretically. It is found that there will be a three way splitting of the main Raman lines due to the interaction of the nanotube phonon with the collective excitations (plasmons) of the conduction electrons of the nanotube as well as its coupling with the phonon of the filling material. The positions and relative strengths of these Raman peaks depend on the strength of the electron-phonon interaction, phonon frequency of the filling atom and the strength of interaction of the nanotube phonon and the phonon of the filling atoms. Careful experimental studies of the Raman spectra of filled nanotubes should show these three peaks. It is also shown that in a semiconducting nanotube the Raman line will split into two and should be observed experimentally
Water sorption and solubility of bulk-fill composites polymerized with a third generation LED LCU
Directory of Open Access Journals (Sweden)
Tuğba MİSİLLİ
2017-10-01
Full Text Available Abstract The aim of this study was to compare the degree of water sorption and solubility in bulk-fills after curing with a polywave light source. A total of 120 disc-shaped specimens (8 mm diameter; 4 mm depth were prepared from three regular bulk-fill materials (X-tra Fil, Tetric N-Ceram Bulk Fill, SonicFill, and a control material (Filtek Z250, cured in 3 different modes (standard: 1000 mW/cm2-20 s; high power: 1400 mW/cm2-12 s; xtra power: 3200 mW/cm2-6 s using a third generation light-emitting diode light curing unit. Water sorption and solubility levels of the specimens were measured according to the ISO 4049:2009 specification after storing in distilled water for 30 days. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test (p < 0.05. The Z250 sample exposed to high power presented a higher sorption compared to the X-tra Fil and SonicFill samples. In xtra power mode, the values of Z250 and SonicFill were similar to each other and higher compared to those of X-tra Fil. Only SonicFill exhibited significantly different sorption values depending on the curing mode, the highest of which was achieved when using the xtra power mode. The highest solubility values were obtained for SonicFill. No statistically significant differences were found among other groups. No significant correlation was detected between water sorption and solubility. The traditional composite group exhibited a higher water sorption values than the bulk-fills. The reduction in polymerization time significantly increased the sorption of SonicFill. SonicFill showed the highest water solubility value among the composites tested.
International Nuclear Information System (INIS)
Bordyuk, N.A.; Nikitchuk, V.I.; Voloshin, O.M.
1995-01-01
The force constants of anharmonicity, the total energy, and the force of interaction between structural elements of PVC systems are determined from the values of the quasielastic constants of filled polymer systems
Interfacial area, velocity and void fraction in two-phase slug flow
International Nuclear Information System (INIS)
Kojasoy, G.; Riznic, J.R.
1997-01-01
The internal flow structure of air-water plug/slug flow in a 50.3 mm dia transparent pipeline has been experimentally investigated by using a four-sensor resistivity probe. Liquid and gas volumetric superficial velocities ranged from 0.55 to 2.20 m/s and 0.27 to 2.20 m/s, respectively, and area-averaged void fractions ranged from about 10 to 70%. The local distributions of void fractions, interfacial area concentration and interface velocity were measured. Contributions from small spherical bubbles and large elongated slug bubbles toward the total void fraction and interfacial area concentration were differentiated. It was observed that the small bubble void contribution to the overall void fraction was small indicating that the large slug bubble void fraction was a dominant factor in determining the total void fraction. However, the small bubble interfacial area contribution was significant in the lower and upper portions of the pipe cross sections
Determination of bone mineral volume fraction using impedance analysis and Bruggeman model
Energy Technology Data Exchange (ETDEWEB)
Ciuchi, Ioana Veronica; Olariu, Cristina Stefania, E-mail: oocristina@yahoo.com; Mitoseriu, Liliana, E-mail: lmtsr@uaic.ro
2013-11-20
Highlights: • Mineral volume fraction of a bone sample was determined. • Dielectric properties for bone sample and for the collagen type I were determined by impedance spectroscopy. • Bruggeman effective medium approximation was applied in order to evaluate mineral volume fraction of the sample. • The computed values were compared with ones derived from a histogram test performed on SEM micrographs. -- Abstract: Measurements by impedance spectroscopy and Bruggeman effective medium approximation model were employed in order to determine the mineral volume fraction of dry bone. This approach assumes that two or more phases are present into the composite: the matrix (environment) and the other ones are inclusion phases. A fragment of femur diaphysis dense bone from a young pig was investigated in its dehydrated state. Measuring the dielectric properties of bone and its main components (hydroxyapatite and collagen) and using the Bruggeman approach, the mineral volume filling factor was determined. The computed volume fraction of the mineral volume fraction was confirmed by a histogram test analysis based on the SEM microstructures. In spite of its simplicity, the method provides a good approximation for the bone mineral volume fraction. The method which uses impedance spectroscopy and EMA modeling can be further developed by considering the conductive components of the bone tissue as a non-invasive in situ impedance technique for bone composition evaluation and monitoring.
Determination of bone mineral volume fraction using impedance analysis and Bruggeman model
International Nuclear Information System (INIS)
Ciuchi, Ioana Veronica; Olariu, Cristina Stefania; Mitoseriu, Liliana
2013-01-01
Highlights: • Mineral volume fraction of a bone sample was determined. • Dielectric properties for bone sample and for the collagen type I were determined by impedance spectroscopy. • Bruggeman effective medium approximation was applied in order to evaluate mineral volume fraction of the sample. • The computed values were compared with ones derived from a histogram test performed on SEM micrographs. -- Abstract: Measurements by impedance spectroscopy and Bruggeman effective medium approximation model were employed in order to determine the mineral volume fraction of dry bone. This approach assumes that two or more phases are present into the composite: the matrix (environment) and the other ones are inclusion phases. A fragment of femur diaphysis dense bone from a young pig was investigated in its dehydrated state. Measuring the dielectric properties of bone and its main components (hydroxyapatite and collagen) and using the Bruggeman approach, the mineral volume filling factor was determined. The computed volume fraction of the mineral volume fraction was confirmed by a histogram test analysis based on the SEM microstructures. In spite of its simplicity, the method provides a good approximation for the bone mineral volume fraction. The method which uses impedance spectroscopy and EMA modeling can be further developed by considering the conductive components of the bone tissue as a non-invasive in situ impedance technique for bone composition evaluation and monitoring
Directory of Open Access Journals (Sweden)
Jianbo TAN
2015-06-01
Full Text Available The filling mold process of semi-solid alloy blank influences severely the forming and properties of finished piece. In this paper, DEFORM is applied to simulate the process of cup-type 6061 alloy die forging casting. The influences of the temperature of semi-solid alloy blank, preheating temperature, and downward press speed of pressure head on process of mold filling and velocity field are investigated. The results show that the mold filling of semi-solid alloy paste smoothly fills along the whole of mould cavity in “total wall thickness” form when the temperature of semi-solid alloy blank is 620 ℃, preheating temperature of pressure head is 200 ℃ and speed of pressure head is 40 mm/s. Along with the increase of the preheating temperature of pressure head, the filling process of the semi-solid alloy paste trends toward stable when the temperature of semi-solid alloy blank is 620 ℃ and the speed of pressure head is 20 mm/s. Along with the increasing of the temperature of semi-solid alloy, the process of mould filling becomes off balance and the liquid becomes turbulent flow. The velocity field in the process of mould filling affects severely the structure uniformity of the finished product.
Sundowo, Andini; Artanti, Nina; Hanafi, M.; Minarti, Primahana, Gian
2017-11-01
C ledgeriana is a medicinal plant that contains alkaloids, especially on the barks for commercial production of quinine as antimalarial. The main alkaloids in this plant are cinchonine, cinchonidine, quinine and quinidine. Besides for antiamalarial this plant is also commonly used to treat whooping cough, influenza and dysentery. Compare to other medicinal plants, nowadays only very few studies were conducted in Cinchona species. Our current study aims to determine the content of phytochemical, total phenol and total flavonoids from C. ledgeriana leaves 70% ethanol extract. The extraction was performed by maceration method using 70% ethanol solvent and then fractionated into hexane, ethylacetate and butanol. Phytochemical screening was performed to determine the content of alkaloids, flavonoids, terpenoids, tannins and saponins. Total phenol and flavonoid contents of the extract were determined by Folin-Ciocalteu and alumunium chloride colorimetric methods using gallic acid and quercetin as standards. The antioxidant activity was determined by using 2, 2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity. The results of phytochemical screening showed that the 70% ethanol extract of C. ledgeriana leaves contained alkaloids, flavonoids, terpenoids, tannins and saponins. The total phenol and total flavonoids analysis showed that ethyl acetate fraction had the highest total phenol (40.23%) and total flavonoids (65.34%).
Premature melt solidification during mold filling and its influence on the as-cast structure
Wu, M.; Ahmadein, M.; Ludwig, A.
2018-03-01
Premature melt solidification is the solidification of a melt during mold filling. In this study, a numerical model is used to analyze the influence of the pouring process on the premature solidification. The numerical model considers three phases, namely, air, melt, and equiaxed crystals. The crystals are assumed to have originated from the heterogeneous nucleation in the undercooled melt resulting from the first contact of the melt with the cold mold during pouring. The transport of the crystals by the melt flow, in accordance with the socalled "big bang" theory, is considered. The crystals are assumed globular in morphology and capable of growing according to the local constitutional undercooling. These crystals can also be remelted by mixing with the superheated melt. As the modeling results, the evolutionary trends of the number density of the crystals and the volume fraction of the solid crystals in the melt during pouring are presented. The calculated number density of the crystals and the volume fraction of the solid crystals in the melt at the end of pouring are used as the initial conditions for the subsequent solidification simulation of the evolution of the as-cast structure. A five-phase volume-average model for mixed columnar-equiaxed solidification is used for the solidification simulation. An improved agreement between the simulation and experimental results is achieved by considering the effect of premature melt solidification during mold filling. Finally, the influences of pouring parameters, namely, pouring temperature, initial mold temperature, and pouring rate, on the premature melt solidification are discussed.
International Nuclear Information System (INIS)
Boucher, C.A.; Wilson, R.A.; Kanarek, D.J.; Hutter, A.M. Jr.; Okada, R.D.; Liberthson, R.R.; Strauss, H.W.; Pohost, G.M.
1983-01-01
Exercise radionuclide angiography is being used to evaluate left ventricular function in patients with aortic regurgitation. Ejection fraction is the most common variable analyzed. To better understand the rest and exercise ejection fraction in this setting, 20 patients with asymptomatic or minimally symptomatic severe aortic regurgitation were studied. All underwent simultaneous supine exercise radionuclide angiography and pulmonary gas exchange measurement and underwent rest and exercise measurement of pulmonary artery wedge pressure (PAWP) during cardiac catheterization. Eight patients had a peak exercise PAWP less than 15 mm Hg (group 1) and 12 had a peak exercise PAWP greater than or equal to 15 mm Hg (group 2). Group 1 patients were younger and more were in New York Heart Association class I. The two groups had similar cardiothoracic ratios, changes in ejection fractions with exercise, and rest and exercise regurgitant indexes. Using multiple regression analysis, the best correlate of the exercise PAWP was peak oxygen uptake (r . -0.78, p less than 0.01). No other measurement added significantly to the regression. When peak oxygen uptake was excluded, rest and exercise ejection fraction also correlated significantly (r . -0.62 and r . -0.60, respectively, p less than 0.01). Patients with asymptomatic or minimally symptomatic severe aortic regurgitation have a wide spectrum of cardiac performance in terms of the PAWP during exercise. The absolute rest and exercise ejection fraction and the level of exercise achieved are noninvasive variables that correlate with exercise PAWP in aortic regurgitation, but the change in ejection fraction with exercise by itself is not
Friction and wear of Synfluo 180XF wax and nano-Al2O3 filled Nomex fabric composites
International Nuclear Information System (INIS)
Su Fenghua; Zhang Zhaozhu; Wang Kun; Liu Weimin
2006-01-01
Nomex fabric composites filled with the particulates of Synfluo 180XF wax (SFW) and nano-Al 2 O 3 was prepared by dip-coating of Nomex fabric in a phenolic resin containing particulates to be incorporated and the successive curing. The friction and wear performance of the pure and filled Nomex fabric composites sliding against AISI-1045 steel in a pin-on-disk configuration were evaluated on a Xuanwu-III high temperature friction and wear tester. The microstructure of the composites, and the morphologies of the worn surfaces and the morphologies of counterpart steel pins were analyzed by means of scanning electron microscopy. And the elemental plane distribution of Al on the cross-section of the Nomex fabric composites filled with nano-Al 2 O 3 was analyzed with an energy dispersive X-ray analyzer (EDAX). The results showed that the addition of Synfluo 180XF wax in composites have the potential to increase wear resistance and friction reduction of Nomex fabric composites, and the addition of the nano-Al 2 O 3 with the optimum mass fraction in composites can improve the anti-wear ability of the composites. Besides the self-properties of the filler, the character of the microstructure of the Nomex fabric composites filled with different particles, coupled with the character of the transfer film, largely accounts for the improved anti-wear and friction-reducing abilities of the filled Nomex fabric composites as compared with the unfilled one
Directory of Open Access Journals (Sweden)
Ciaciuch Anna
2017-09-01
Full Text Available The research presents the changes in chemical oxygen demand (COD fractions during the two-stage thermal disintegration and anaerobic digestion (AD of sewage sludge in municipal wastewater treatment plant (WWTP. Four COD fractions have been separated taking into account the solubility of substrates and their susceptibility to biodegradation: inert soluble organic matter SI, readily biodegradable substrate SS, slowly biodegradable substrates XS and inert particulate organic material XI. The results showed that readily biodegradable substrates SS (46.8% of total COD and slowly biodegradable substrates XS (36.1% of total COD were dominant in the raw sludge effluents. In sewage effluents after two-stage thermal disintegration, the percentage of SS fraction increased to 90% of total COD and percentage of XS fraction decreased to 8% of total COD. After AD, percentage of SS fraction in total COD decreased to 64%, whereas the percentage of other fractions in effluents increased.
Soil tension mediates isotope fractionation during soil water evaporation
Gaj, Marcel; McDonnell, Jeffrey
2017-04-01
Isotope tracing of the water cycle is increasing in its use and usefulness. Many new studies are extracting soil waters and relating these to streamflow, groundwater recharge and plant transpiration. Nevertheless, unlike isotope fractionation factors from open water bodies, soil water fractionation factors are poorly understood and until now, only empirically derived. In contrast to open water evaporation where temperature, humidity and vapor pressure gradient define fractionation (as codified in the well-known Craig and Gordon model), soil water evaporation includes additionally, fractionation by matrix effects. There is yet no physical explanation of kinetic and equilibrium fraction from soil water within the soil profile. Here we present a simple laboratory experiment with four admixtures of soil grain size (from sand to silt to clay). Oven-dried samples were spiked with water of known isotopic composition at different soil water contents. Soils were then stored in sealed bags and the headspace filled with dry air and allowed to equilibrate for 24hours. Isotopic analysis of the headspace vapor was done with a Los Gatos Inc. water vapor isotope analyzer. Soil water potential of subsamples were measured with a water potential meter. We show for the first time that soil tension controls isotope fractionation in the resident soil water. Below a Pf 3.5 the δ-values of 18O and 2H of the headspace vapor is more positive and increases with increasing soil water potential. Surprisingly, we find that the relationship between soil tension and equilibrium fractionation is independent of soil type. However, δ-values of each soil type plot along a distinct evaporation line. These results indicate that equilibrium fractionation is affected by soil tension in addition to temperature. Therefore, at high soil water tension (under dry conditions) equilibrium fractionation is not consistent with current empirical formulations that ignore these effects. These findings may have
Fragility of the fractional quantum spin Hall effect in quantum gases
International Nuclear Information System (INIS)
Fialko, O; Brand, J; Zülicke, U
2014-01-01
We consider the effect of contact interaction in a prototypical quantum spin Hall system of pseudo-spin-1/2 particles. A strong effective magnetic field with opposite directions for the two spin states restricts two-dimensional particle motion to the lowest Landau level. While interaction between same-spin particles leads to incompressible correlated states at fractional filling factors as known from the fractional quantum Hall effect, these states are destabilized by interactions between opposite spin particles. Exact results for two particles with opposite spin reveal a quasi-continuous spectrum of extended states with a large density of states at low energy. This has implications for the prospects of realizing the fractional quantum spin Hall effect in electronic or ultra-cold atom systems. Numerical diagonalization is used to extend the two-particle results to many bosonic particles and trapped systems. The interplay between an external trapping potential and spin-dependent interactions is shown to open up new possibilities for engineering exotic correlated many-particle states with ultra-cold atoms. (paper)
Taniguchi, Naofumi; Jinno, Tetsuya; Koga, Daisuke; Hagino, Tetsuo; Okawa, Atsushi; Haro, Hirotaka
2017-05-01
Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems. Copyright © 2016 Elsevier Inc. All rights reserved.
Cataract incidence after total-body irradiation
International Nuclear Information System (INIS)
Zierhut, D.; Lohr, F.; Schraube, P.; Huber, P.; Haas, R.; Hunstein, W.; Wannenmacher, M.
1997-01-01
Purpose: Aim of this retrospective study was to evaluate cataract incidence in a homogeneous group of patients after total-body irradiation followed by autologous bone marrow transplantation or peripheral blood stem cell transplantation. Method and Materials: Between 11/1982 and 6/1994 in total 260 patients received in our hospital total-body irradiation for treatment of haematological malignancy. In 1996-96 patients out of these 260 patients were still alive. 85 from these still living patients (52 men, 33 women) answered evaluable on a questionnaire and could be examined ophthalmologically. Median age of these patients was 38,5 years (15 - 59 years) at time of total-body irradiation. Radiotherapy was applied as hyperfractionated total-body irradiation with a median dose of 14,4 Gy in 12 fractions over 4 days. Minimum time between fractions was 4 hours, photons with a energy of 23 MeV were used, and the dose rate was 7 - 18 cGy/min. Results: Median follow-up is now 5,8 years (1,7 - 13 years). Cataract occurred in (28(85)) patients after a median time of 47 months (1 - 104 months). In 6 out of these 28 patients who developed a cataract, surgery of the cataract was performed. Whole-brain irradiation prior to total-body irradiation was more often in the group of patients developing a cataract (14,3%) vs. 10,7% in the group of patients without cataract. Conclusion: Cataract is a common side effect of total-body irradiation. Cataract incidence found in our patients is comparable to results of other centres using a fractionated regimen for total-body irradiation. The hyperfractionated regimen used in our hospital does obviously not result in a even lower cataract incidence. In contrast to acute and late toxicity in other organ/organsystems, hyperfractionation of total-body irradiation does not further reduce toxicity for the eye-lens. Dose rate may have more influence on cataract incidence
Cytotoxic and biological effects of bulk fill composites on rat cortical neuron cells.
Kamalak, Hakan; Kamalak, Aliye; Taghizadehghalehjoughi, Ali; Hacımüftüoğlu, Ahmet; Nalcı, Kemal Alp
2018-03-28
The aim of this study was to investigate potential cellular responses and biological effects of new generation dental composites on cortical neuron cells in two different exposure times. The study group included five different bulk-fill flow able composites; Surefil SDR Flow, X-tra Base Flow, Venus Bulk Flow, Filtek Bulk Flow and Tetric-Evo Flow. They were filled in Teflon molds (Height: 4 mm, Width: 6 mm) and irradiated for 20 s. Cortical neuron cells were inoculated into 24-well plates. After 80% of the wells were coated, the 3 µm membrane was inserted and dental filling materials were added. The experiment was continued for 24 and 72 h. Cell viability measured by MTT assay test, total antioxidant and total oxidant status were examined using real assay diagnostic kits. The patterns of cell death (apoptosis) were analyzed using annexin V-FITC staining with flow cytometry. Β-defensins were quantitatively assessed by RT-PCR. IL-6, IL-8 and IL-10 cytokines were measured from the supernatants. All composites significantly affected analyses parameters during the exposure durations. Our data provide evidence that all dental materials tested are cytotoxic in acute phase and these effects are induced cellular death after different exposure periods. Significant cytotoxicity was detected in TE, XB, SS, FBF and VBF groups at 24 and 72 h, respectively.
Energy Technology Data Exchange (ETDEWEB)
Beng, Yeo Kiam; Tzeng, Woo Wen [Universiti Malaysia Sabah, Sabah (Malaysia)
2017-02-15
This study presents the finite element analysis of plastic collapse and energy absorption of polyurethane-filled aluminium circular tubes under quasi-static transverse loading. Increasing focuses were given to impact damage of structures where energy absorbed during impact could be controlled to avoid total structure collapse of energy absorbers and devices designed to dissipate energy. ABAQUS finite element analysis application was utilized for modelling and simulating the polyurethane-filled aluminium tubes, different set of diameterto- thickness ratios and span lengths, subjected to transverse three-point-bending load. Different sets of polyurethane-filled aluminium tubes subjected to the transverse loading were modelled and simulated. The failure modes and mechanisms of filled tubes and its capabilities as energy absorbers to further improve and strengthening of empty tube were also identified. The results showed that plastic deformation response was affected by the geometric constraints and parameters of the specimens. The diameter-to-thickness ratio and span lengths had shown to play crucial role in optimizing the PU-filled tube as energy absorber.
Utilization of Different Corn Fractions by Broilers
Directory of Open Access Journals (Sweden)
SIFR Costa
2015-09-01
Full Text Available ABSTRACTThis study was conducted to evaluate the nutritional values of fractions of damaged corn. One hundred and eighty 22-d-old Cobb 500 male broilers were distributed in batteries according to a completely randomized design with six treatments of six replicates each. The treatments consisted of diets containing five corn fractions, classified as sound, fermented, insect-damaged, mold-damaged, or reference corn. The test diets consisted of 60% of reference diet + 40% of each corn fraction. Only the reference corn fraction included all the fractions at different proportions (0.8% fermented, 0.05% insect-damaged, 3.3% mold-damaged, and 95.85% sound grains. The method of total excreta collection was used to determine AMEn values and metabolizability coefficients of dry matter (MDM, crude protein (MCP, ether extract (MEE, and gross energy (MGE of the reference corn and its fractions. The density values of the corn fractions were used to calculate the correlations among the evaluated parameters. The evaluated corn fractions presented different compositions values. The insect-damaged and mold-damaged grains presented higher CP level, lower density, and MDM and MCP coefficients compared with the other fractions. However, calculated AMEn values were not significantly different (p>0.05 among corn fractions. A low correlation between density and AMEn content (r0.8 were calculated. Although the evaluated corn fractions presented different nutritional values, there were no marked differences in their utilization by broilers.
Antioxidant Activities of Methanol Extract and Solvent Fractions of ...
African Journals Online (AJOL)
Purpose: To determine the antioxidant activity of methanol extract (ME) and solvent fractions of Avrainvillea erecta as well as their total phenolic and flavonoid contents. Methods: The antioxidant activities of ME as well as its chloroform, butanol, and aqueous fractions (CF, BF and WF, respectively) of A. erecta were ...
Directory of Open Access Journals (Sweden)
Joice Cleide de Oliveira Rita
2013-10-01
Full Text Available In unfertilized, highly weathered tropical soils, phosphorus (P availability to plants is dependent on the mineralization of organic P (Po compounds. The objective of this study was to estimate the mineralization of total and labile Po in soil size fractions of > 2.0, 2.0-0.25 and 2.0 and 2.0-0.25 mm fractions, respectively. In contrast, there was an average increase of 90 % of total Po in microaggregates of 2.0 (-50 % and < 0.25 mm (-76 % fractions, but labile Po increased by 35 % in the 2.0-0.25 mm fraction. The Po fraction relative to total extracted P and total labile P within the soil size fractions varied with the vegetation cover and incubation time. Therefore, the distribution of P fractions (Pi and Po in the soil size fraction revealed the distinctive ability of the cover species to recycle soil P. Consequently, the potential of Po mineralization varied with the size fraction and vegetation cover. Because Po accounted for most of the total labile P, the P availability to plants was closely related to the mineralization of this P fraction.
Particle-hole symmetry and composite fermions in fractional quantum Hall states
Nguyen, Dung Xuan; Golkar, Siavash; Roberts, Matthew M.; Son, Dam Thanh
2018-05-01
We study fractional quantum Hall states at filling fractions in the Jain sequences using the framework of composite Dirac fermions. Synthesizing previous work, we write an effective field theory consistent with all symmetry requirements, including Galilean invariance and particle-hole symmetry. Employing a Fermi-liquid description, we demonstrate the appearance of the Girvin-Macdonald-Platzman algebra and compute the dispersion relation of neutral excitations and various response functions. Our results satisfy requirements of particle-hole symmetry. We show that while the dispersion relation obtained from the modified random-phase approximation (MRPA) of the Halperin-Lee-Read (HLR) theory is particle-hole symmetric, correlation functions obtained from this scheme are not. The results of the Dirac theory are shown to be consistent with the Haldane bound on the projected structure factor, while those of the MPRA of the HLR theory violate it.
Directory of Open Access Journals (Sweden)
Pržulj Novo
2011-01-01
Full Text Available In wheat, rate and duration of dry matter accumulation and remobilization depend on genotype and growing conditions. The objective of this study was to determine the most appropriate polynomial regression of stepwise regression procedure for describing grain filling period in three winter wheat cultivars. The stepwise regression procedure showed that grain filling is a complex biological process and that it is difficult to offer a simple and appropriate polynomial equation that fits the pattern of changes in dry matter accumulation during the grain filling period, i.e., from anthesis to maximum grain weight, in winter wheat. If grain filling is to be represented with a high power polynomial, quartic and quintic equations showed to be most appropriate. In spite of certain disadvantages, a cubic equation of stepwise regression could be used for describing the pattern of winter wheat grain filling.
Effect of Opalescence(®) bleaching gels on the elution of bulk-fill composite components.
Schuster, Lena; Reichl, Franz-Xaver; Rothmund, Lena; He, Xiuli; Yang, Yang; Van Landuyt, Kirsten L; Kehe, Kai; Polydorou, Olga; Hickel, Reinhard; Högg, Christof
2016-02-01
Bleaching treatments can affect release of components from conventional composites. In this continuing study the influence of two different bleaching gels on the elution of bulk-fill composite components was investigated. The composites Tetric EvoCeram(®) Bulk Fill, QuiXFil™ and X-tra fil were treated with the bleaching gels Opalescence PF 15% (PF 15%) for 5 h and PF 35% (PF 35%) for 30 min and then stored in methanol and water for 24 h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). Unbleached specimens were used as control group. A total of 7 different elutable substances have been identified from the investigated composites after bleaching-treatment. Three of them were methacrylates: 2-hydroxyethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA) and trimethylolpropane trimethacrylate (TMPTMA). Compared to the unbleached controls an increase in elution after PF 15%-treatment of following compounds was found: HEMA (Tetric EvoCeram(®) Bulk Fill), TEGDMA (QuiXFil™, X-tra fil) and 4-N,N-dimethylaminobenzoic acid butyl ethoxy ester (DMABEE) (Tetric EvoCeram(®) Bulk Fill, QuiXFil™, X-tra fil). Following compounds showed a reduction in elution after PF 35%-treatment compared to controls: TEGDMA (QuiXFil™) and DMABEE (Tetric EvoCeram(®) Bulk Fill). The highest concentration of HEMA was 0.22 mmol/l (Tetric EvoCeram(®) Bulk Fill, methanol, 7 d, PF 15%), the highest concentration of TEGDMA was 0.3 mmol/l (X-tra fil, water, 7 d, PF 15%) and the highest concentration of DMABEE was 0.05 mmol/l (QuiXFil™, water, 7 d, PF 35%). PF 15% and PF 35% can lead to reduced and/or increased elution of some bulk-fill components, compared to unbleached bulk-fill composites. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Irle, C.; Deeg, H.J.; Buckner, C.D.; Swedish Hospital Medical Center, Seattle, WA; Veterans Administration Hospital, Seattle, WA; Washington Univ., Seattle
1985-01-01
Fifty-six patients, 30-47 yr of age, with leukemia in relapse received allogeneic marrow transplants from HLA-identical siblings. All patients were treated with cyclophosphamide (120 mg/kg) and 7 daily fractions of 2.25 Gy of total body irradiation (TBI) for seven consecutive days. Nine patients (16%) are currently alive, free of disease, 324-845 days from transplantation. Actuarial relapse and survival rates at 2 yr were 56% and 9.5% respectively. These data were not remarkably different from those in previous studies using 10 Gy of TBI administered as a single dose. Thirty patients were randomized to receive methotrexate (MTX) and 26 to receive cyclosporine (CSP) as postgrafting prophylaxis for acute graft-versus-host disease (GVHD). Probability of developing significant acute GVHD by day 100 post-transplant was 71% for patients in the MTX group and 45% for patients in the CSP group (p<0.05). Probability of relapse was 37% for patients in the MTX group and 70% for patients in the CSP group (p<0.05). Transplant-related deaths were more frequent in the MTX group and leukemic deaths more frequent in the CSP group although this may have been related to an uneven distribution of high-risk patients. Long term disease-free survival was comparable. (author)
Fractional statistics and quantum scaling properties of the integrable Penson-Kolb-Hubbard chain
Vitoriano, Carlindo; Coutinho-Filho, M. D.
2010-09-01
We investigate the ground-state and low-temperature properties of the integrable version of the Penson-Kolb-Hubbard chain. The model obeys fractional statistical properties, which give rise to fractional elementary excitations and manifest differently in the four regions of the phase diagram U/t versus n , where U is the Coulomb coupling, t is the correlated hopping amplitude, and n is the particle density. In fact, we can find local pair formation, fractionalization of the average occupation number per orbital k , or U - and n -dependent average electric charge per orbital k . We also study the scaling behavior near the U -driven quantum phase transitions and characterize their universality classes. Finally, it is shown that in the regime of parameters where local pair formation is energetically more favorable, the ground state exhibits power-law superconductivity; we also stress that above half filling the pair-hopping term stabilizes local Cooper pairs in the repulsive- U regime for U
In vitro assessment of relief to oxidative stress by different fractions of Boerhavia procumbens.
Abbasi, Muhammad Athar; Rubab, Kaniz; Rehman, Azizur; Riaz, Tauheeda; Shahzadi, Tayyaba; Khalid, Muniba; Ajaib, Muhammad
2012-04-01
Methanolic extract of Boerhavia procumbens Bank ex Roxb. was partitioned with n-hexane, chloroform, ethyl acetate and n-butanol sequentially after dissolving in distilled water. Phytochemical screening showed presence of phenolics, flavonoides and cardiac glycosides in large amount in chloroform, ethyl acetate and n-butanol soluble fraction. The antioxidant activity of all these fractions and the remaining aqueous fraction was evaluated by four methods such as: 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging activity, ferric reducing antioxidant power (FRAP) assay, total antioxidant activity and ferric thiocyanate assay. Total phenolics were also determined. Some fractions showed noteworthy antioxidant activity. The results of the antioxidant activity revealed that the ethyl acetate soluble fraction showed the highest value of percent inhibition of DPPH (82.54 ± 0.62) at the concentration of 125 μ g/ml. The IC(50) of this fraction was 37.11± 0.23 μg/ml, compared with butylated hydroxytoluene (BHT), which have IC(50) of 12.1 ± 0.92 μ/mL. It also showed the highest FRAP value (251.08 ± 1.46 μg of trolox equivalents) as well as the highest value of lipid peroxidation inhibition (57.21 ± 52%), the highest total antioxidant activity (0.549 ± 0.08) and also the highest total phenolic contents (77.1 ± 0.6) as compared to the studied fractions. Phytochemical screening showed high percentage of phenolics, flavonoides and cardiac glycosides in this fraction.
International Nuclear Information System (INIS)
Filiberti, A.W.; Bianco, J.A.; Baker, S.P.; Doherty; Nalivaika, L.A.; King, M.A.; Alpert, J.S.
1984-01-01
Early peak diastolic filling rate (PFR) of the left ventricle (LV) is said to be a sensitive index of LV dysfunction in patients with coronary disease, hypertension and hypertrophic cardiomyopathy. Radionuclide (RN0 multigated PFR was measured in 20 normal volunteers (13 males, 7 females, mean age 31 yrs., range 20-43) at rest and during supine bicycle exercise conducted to a symptomatic end-point. At rest, RN PFR was 3.4 +- SD 0.4 end-diastolic vols./sec (range 3.1 - 3.6). During exercise all normal volunteers had a progressive and numerically and statistically significant increase in PFR. Stepwise multiple linear regression (BMPD2R) was applied to the rest and exercise PFR data to develop a linear model describing the main determinants of the RN PFR. The potential independent variables which were included in the model were heart rate (HR), ejection fraction (EF), systolic arterial pressure, systolic ejection rate and exercise stage. Ranking of variables for prediction of RN PFR, and exclusion of less important variables, was done by F value criteria. The final multivariate equation was: LVPFR = -3.84437 + 0.03834 HR + 0.07537 LVEF. The model fit was highly significant (p<0.001), and accounted for 89 per cent of variability in the PFR. The authors conclude that the left ventricular peak filling rate is critically determined by heart rate and by ejection fraction at rest and during exercise
A holographic model for the fractional quantum Hall effect
Energy Technology Data Exchange (ETDEWEB)
Lippert, Matthew [Institute for Theoretical Physics, University of Amsterdam,Science Park 904, 1090GL Amsterdam (Netherlands); Meyer, René [Kavli Institute for the Physics and Mathematics of the Universe (WPI), The University of Tokyo,Kashiwa, Chiba 277-8568 (Japan); Taliotis, Anastasios [Theoretische Natuurkunde, Vrije Universiteit Brussel andThe International Solvay Institutes,Pleinlaan 2, B-1050 Brussels (Belgium)
2015-01-08
Experimental data for fractional quantum Hall systems can to a large extent be explained by assuming the existence of a Γ{sub 0}(2) modular symmetry group commuting with the renormalization group flow and hence mapping different phases of two-dimensional electron gases into each other. Based on this insight, we construct a phenomenological holographic model which captures many features of the fractional quantum Hall effect. Using an SL(2,ℤ)-invariant Einstein-Maxwell-axio-dilaton theory capturing the important modular transformation properties of quantum Hall physics, we find dyonic diatonic black hole solutions which are gapped and have a Hall conductivity equal to the filling fraction, as expected for quantum Hall states. We also provide several technical results on the general behavior of the gauge field fluctuations around these dyonic dilatonic black hole solutions: we specify a sufficient criterion for IR normalizability of the fluctuations, demonstrate the preservation of the gap under the SL(2,ℤ) action, and prove that the singularity of the fluctuation problem in the presence of a magnetic field is an accessory singularity. We finish with a preliminary investigation of the possible IR scaling solutions of our model and some speculations on how they could be important for the observed universality of quantum Hall transitions.
A holographic model for the fractional quantum Hall effect
Lippert, Matthew; Meyer, René; Taliotis, Anastasios
2015-01-01
Experimental data for fractional quantum Hall systems can to a large extent be explained by assuming the existence of a Γ0(2) modular symmetry group commuting with the renormalization group flow and hence mapping different phases of two-dimensional electron gases into each other. Based on this insight, we construct a phenomenological holographic model which captures many features of the fractional quantum Hall effect. Using an -invariant Einstein-Maxwell-axio-dilaton theory capturing the important modular transformation properties of quantum Hall physics, we find dyonic diatonic black hole solutions which are gapped and have a Hall conductivity equal to the filling fraction, as expected for quantum Hall states. We also provide several technical results on the general behavior of the gauge field fluctuations around these dyonic dilatonic black hole solutions: we specify a sufficient criterion for IR normalizability of the fluctuations, demonstrate the preservation of the gap under the action, and prove that the singularity of the fluctuation problem in the presence of a magnetic field is an accessory singularity. We finish with a preliminary investigation of the possible IR scaling solutions of our model and some speculations on how they could be important for the observed universality of quantum Hall transitions.
Study of Fractions in Elementary Mathematics Textbooks from Finland and Taiwan
Yang, Der-Ching
2018-01-01
This study examines the different ways in which fractions are dealt with in two elementary mathematics textbook series: Kang Hsuan (KH) in Taiwan and Laskutaito in Finland. The results showed that the total number of fraction questions in Laskutaito is higher than that in KH and that Laskutaito highlights the basic definition of fractions to help…
Paulson, Anthony J.; Conn, Kathleen E.; DeWild, John F.
2013-01-01
Previous investigations examined sources and sinks of mercury to Sinclair Inlet based on historic and new data. This included an evaluation of mercury concentrations from various sources and mercury loadings from industrial discharges and groundwater flowing from the Bremerton naval complex to Sinclair Inlet. This report provides new data from four potential sources of mercury to Sinclair Inlet: (1) filtered and particulate total mercury concentrations of creek water during the wet season, (2) filtered and particulate total mercury releases from the Navy steam plant following changes in the water softening process and discharge operations, (3) release of mercury from soils to groundwater in two landfill areas at the Bremerton naval complex, and (4) total mercury concentrations of solids in dry dock sumps that were not affected by bias from sequential sampling. The previous estimate of the loading of filtered total mercury from Sinclair Inlet creeks was based solely on dry season samples. Concentrations of filtered total mercury in creek samples collected during wet weather were significantly higher than dry weather concentrations, which increased the estimated loading of filtered total mercury from creek basins from 27.1 to 78.1 grams per year. Changes in the concentrations and loading of filtered and particulate total mercury in the effluent of the steam plant were investigated after the water softening process was changed from ion-exchange to reverse osmosis and the discharge of stack blow-down wash began to be diverted to the municipal water-treatment plant. These changes reduced the concentrations of filtered and particulate total mercury from the steam plant of the Bremerton naval complex, which resulted in reduced loadings of filtered total mercury from 5.9 to 0.15 grams per year. Previous investigations identified three fill areas on the Bremerton naval complex, of which the western fill area is thought to be the largest source of mercury on the base
Iron filled carbon nanostructures from different precursors
International Nuclear Information System (INIS)
Costa, S.; Borowiak-Palen, E.; Bachmatiuk, A.; Ruemmeli, M.H.; Gemming, T.; Kalenczuk, R.J.
2008-01-01
Here, we present a study on the synthesis of different nanostructures with one single-step in situ filling (encapsulation) via carbon vapor deposition (CVD). Ferrocene, acetylferrocene and iron (II) nitrate as iron precursors were explored. The application of each of these compounds resulted in different carbon nanomaterials such as: iron filled multiwalled carbon nanotubes with a low filling ratio (Fe-MWCNT), iron filled nanocapsules and unfilled MWCNT. The as-produced samples were purified by high temperature annealing and acid treatment. The purified materials were characterised using transmission electron microscopy (TEM) and Raman spectroscopy
Chai, Tsun-Thai; Khoo, Chee-Siong; Tee, Chong-Siang; Wong, Fai-Chu
2016-01-01
Alternanthera sessilis is a medicinal herb which is consumed as vegetable and used as traditional remedies of various ailments in Asia and Africa. This study aimed to investigate the antiglucosidase and antioxidant activity of solvent fractions of A. sessilis leaf and callus. Leaf and callus methanol extracts were fractionated to produce hexane, chloroform, ethyl acetate, butanol, and water fractions. Antiglucosidase and 1,1-diphenyl-2-picrylhydrazyl scavenging activities as well as total phenolic (TP), total flavonoid (TF), and total coumarin (TC) contents were evaluated. Lineweaver-Burk plot analysis was performed on leaf and callus fractions with the strongest antiglucosidase activity. Leaf ethyl acetate fraction (LEF) had the strongest antiglucosidase (EC 50 0.55 mg/mL) and radical scavenging (EC 50 10.81 μg/mL) activity among leaf fractions. Callus ethyl acetate fraction (CEF) and chloroform fraction had the highest antiglucosidase (EC 50 0.25 mg/mL) and radical scavenging (EC 50 34.12 μg/mL) activity, respectively, among callus fractions. LEF and CEF were identified as noncompetitive and competitive α-glucosidase inhibitors, respectively. LEF and CEF had greater antiglucosidase activity than acarbose. Leaf fractions had higher phytochemical contents than callus fractions. LEF had the highest TP, TF, and TC contents. Antiglucosidase and antioxidant activities of leaf fractions correlated with phytochemical contents. LEF had potent antiglucosidase activity and concurrent antioxidant activity. CEF had the highest antiglucosidase activity among all fractions. Callus culture is a promising tool for enhancing production of potent α-glucosidase inhibitors. Leaf ethyl acetate fraction (LEF) had the strongest antiglucosidase (EC 50 0.55 mg/mL) and radical scavenging (EC 50 10.81 μg/mL) activity among leaf fractionsCallus ethyl acetate fraction (CEF) and chloroform fraction had the highest antiglucosidase (EC 50 0.25 mg/mL) and radical scavenging (EC 50 34.12
46 CFR 98.25-65 - Filling density.
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Filling density. 98.25-65 Section 98.25-65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS SPECIAL... § 98.25-65 Filling density. (a) The filling density, or the percent ratio of the liquefied gas that may...
Characterization of the Water-Soluble Fraction of Woody Biomass Pyrolysis Oils
Energy Technology Data Exchange (ETDEWEB)
Stankovikj, Filip; McDonald, Armando G.; Helms, Gregory L.; Olarte, Mariefel V.; Garcia-Perez, Manuel
2017-01-31
This paper reports a study of the chemical composition of the water soluble (WS) fraction obtained by cold water precipitation of two commercial wood pyrolysis oils (BTG and Amaron). The fraction studied accounts for between 50.3 and 51.3 wt. % of the oils. With the most common analytical techniques used today for the characterization of this fraction (KF titration, GC/MS, hydrolysable sugars and total carbohydrates), it is possible to quantify only between 45 and 50 wt. % of it. Our results confirm that most of the total carbohydrates (hydrolysable sugars and non-hydrolysable) are soluble in water. The ion chromatography hydrolysis method showed that between 11.6 and 17.3 wt. % of these oils were hydrolysable sugars. A small quantity of phenols detectable by GC/MS (between 2.5 and 3.9 wt. %) were identified. It is postulated that the unknown high molecular weight fraction (30-55 wt. %) is formed by highly dehydrated sugars rich in carbonyl groups and WS phenols. The overall content of carbonyl, carboxyl, hydroxyl and phenolic compounds in the WS fraction were quantified by titration, Folin-Ciocalteu, 31P-NMR and 1H-NMR. The WS fraction contains between 5.5 and 6.2 mmol/g of carbonyl groups, between 0.4 and 1.0 mmol/g of carboxylic acid groups, between 1.2 and 1.8 mmol/g phenolic -OH, and between 6.0 and 7.9 mmol/g of aliphatic alcohol groups. Translation into weight fractions of the WS was done by supposing surrogate structures for the water soluble phenols, carbonyl and carboxyl groups and we estimated the content of WS phenols (21-27 wt. %), carbonyl (5-14 wt.%), and carboxyl (0-4 wt.%). Together with the total carbohydrates (23-27 wt.%), this approach leads to > 90 wt. % of the WS material in the bio-oils being quantified. We speculate the larger portion of the difference between the total carbohydrates and hydrolysable sugars is the missing furanic fraction. Further refinement of the suggested methods and development of separation schemes to obtain and
DEFF Research Database (Denmark)
Witgen, Brent Marvin; Grady, M. Sean; Nyengaard, Jens Randel
2006-01-01
The quantification of ultrastructure has been permanently improved by the application of new stereological principles. Both precision and efficiency have been enhanced. Here we report for the first time a fractionator method that can be applied at the electron microscopy level. This new design...... the total object number using section sampling fractions based on the average thickness of sections of variable thicknesses. As an alternative, this approach estimates the correct particle section sampling probability based on an estimator of the Horvitz-Thompson type, resulting in a theoretically more...
Yan, Han; Manion, Joseph G; Yuan, Mingjian; García de Arquer, F Pelayo; McKeown, George R; Beaupré, Serge; Leclerc, Mario; Sargent, Edward H; Seferos, Dwight S
2016-08-01
Intrinsic traps in organic semiconductors can be eliminated by trap-filling with F4-TCNQ. Photovoltaic tests show that devices with F4-TCNQ at parts per thousand concentration outperform control devices due to an improved fill factor. Further studies confirm the trap-filling pathway and demonstrate the general nature of this finding. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Filled aperture concepts for the Terrestrial Planet Finder
Ridgway, Stephen T.
2003-02-01
Filled aperture telescopes can deliver a real, high Strehl image which is well suited for discrimination of faint planets in the vicinity of bright stars and against an extended exo-zodiacal light. A filled aperture offers a rich variety of PSF control and diffraction suppression techniques. Filled apertures are under consideration for a wide spectral range, including visible and thermal-IR, each of which offers a significant selection of biomarker molecular bands. A filled aperture visible TPF may be simpler in several respects than a thermal-IR nuller. The required aperture size (or baseline) is much smaller, and no cryogenic systems are required. A filled aperture TPF would look and act like a normal telescope - vendors and users alike would be comfortable with its design and operation. Filled aperture telescopes pose significant challenges in production of large primary mirrors, and in very stringent wavefront requirements. Stability of the wavefront control, and hence of the PSF, is a major issue for filled aperture systems. Several groups have concluded that these and other issues can be resolved, and that filled aperture options are competitive for a TPF precursor and/or for the full TPF mission. Ball, Boeing-SVS and TRW have recently returned architecture reviews on filled aperture TPF concepts. In this paper, I will review some of the major considerations underlying these filled aperture concepts, and suggest key issues in a TPF Buyers Guide.
DEFF Research Database (Denmark)
Coimbatore Balram, Ajit; Jain, Jainendra
2017-01-01
The particle-hole (PH) symmetry of {\\em electrons} is an exact symmetry of the electronic Hamiltonian confined to a specific Landau level, and its interplay with the formation of composite fermions has attracted much attention of late. This article investigates an emergent symmetry...... in the fractional quantum Hall effect, namely the PH symmetry of {\\em composite fermions}, which relates states at composite fermion filling factors $\
Dhingra, Naveen; Sharma, Rajesh; Kar, Anand
2014-11-01
In the present study we have evaluated the antioxidant activities of different fractions (hexane, ethyl acetate, n-butanol and aqueous fractions) of Prunus persica fruit. For extraction simple warring blender method was employed and total phenolic and flavonoid contents were correlated with different antioxidant activities (total antioxidant, 2,2-diphenyl-1-picrylhydrazyl (DPPH), H2O2 scavenging, superoxide radical scavenging, iron chelating and their reducing power properties). Different in vitro antioxidant studies showed that ethyl acetate and n-butanol fractions had the maximum activities that were well correlated with total phenolic and flavonoid contents. Maximum yield (25.14 ± 2.2%) was obtained in its aqueous fraction. Both ethyl acetate and n-butanol fractions showed significant inhibitory effects on different antioxidant activities. A significantly high correlation coefficient existed between total antioxidant activities and with total phenolic as well as total flavonoid contents. It appears that ethyl acetate and n-butanol fractions of P. persica may serve as new potential sources of natural antioxidants and could be of therapeutic use in treating several diseases.
Garcia-Montilla, Romel; Imam, Faryal; Miao, Mi; Stinson, Kathryn; Khan, Akram; Heitner, Stephen
2017-06-01
Right ventricular (RV) systolic dysfunction is common in acute respiratory distress syndrome (ARDS). While preload optimization is crucial in its management, dynamic fluid responsiveness indices lack reliability, and there is no consensus on target central venous pressure (CVP). We analyzed the utility of RV free wall longitudinal strain (RVFWS) in the estimation of optimal RV filling pressure in ARDS. A retrospective cross-sectional analysis of clinical data and echocardiograms of patients with ARDS was performed. Tricuspid annular plane systolic excursion (TAPSE), tricuspid peak systolic velocity (S'), RV fractional area change (RVFAC), RVFWS, CVP, systolic pulmonary artery pressure (SPAP), and left ventricular ejection fraction (LVEF) were measured. Fifty-one patients with moderate-severe ARDS were included. There were inverse correlations between CVP and TAPSE, S', RVFAC, RVFWS, and LVEF. The most significant was with RVFWS (r:.74, R 2 :.55, P:.00001). Direct correlations with creatinine and lactate were noted. Receiver operating characteristic analysis showed that RVFWS -21% (normal reference value) was associated with CVP: 13 mm Hg (AUC: 0.92, 95% CI: 0.83-1.00). Regression model analysis of CVP, and RVFWS interactions established an RVFWS range from -18% to -24%. RVFWS -24% corresponded to CVP: 11 mm Hg and RVFWS -18% to CVP: 15 mm Hg. Beyond a CVP of 15 mm Hg, biventricular systolic dysfunction rapidly ensues. Our data are the first to show that an RV filling pressure of 13±2 mm Hg-as by CVP-correlates with optimal RV mechanics as evaluated by strain echocardiography in patients with moderate-severe ARDS. © 2017, Wiley Periodicals, Inc.
DEFF Research Database (Denmark)
Weidemann, E.; Allegrini, Elisa; Astrup, Thomas Fruergaard
2016-01-01
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) formed in modern Waste-to-Energy plants are primarily found in the generated ashes and air pollution control residues, which are usually disposed of as hazardous waste. The objective of this study was to explore the occurrence of PCDD....../F in different grain size fractions in the boiler ash, i.e. ash originating from the convection pass of the boiler. If a correlation between particle size and dioxin concentrations could be found, size fractionation of the ashes could reduce the total amount of hazardous waste. Boiler ash samples from ten...... sections of a boiler's convective part were collected over three sampling days, sieved into three different size fractions - 0.355. mm - and analysed for PCDD/F. The coarse fraction (>0.355. mm) in the first sections of the horizontal convection pass appeared to be of low toxicity with respect to dioxin...
Small dose multi-fractionation therapy, its radiobiological aspects and clinics
International Nuclear Information System (INIS)
Iwai, Hiroshi; Katagiri, Shiro; Furuhata, Akihiko; Fukusi, Itsuhisa
1979-01-01
Recent radiobiological data reveal that cell killings by small dose fractionation are almost due to nonrepairable damage with low oxygen enhancement ratio. Then, Small dose multi-fractionation method suggests a higher therapeutic-ratio than that in conventional high dose fractionated irradiation. Using these data of radiobiology, intermittent irradiations three times a day, four hours interval, with 60 - 80 rads for multi-fractionation, with high total doses of 7,200 - 7,500 rads/6.5 - 7 weeks mainly on bladder, laryngeal and esophageal tumour are applied. The results obtained are slightly improved. (author)
Uranium release from different size fractions of sediments in Hanford 300 area, Washington, USA
International Nuclear Information System (INIS)
Du Jiangkun; Bao Jianguo; Hu Qinhong; Ewing, Robert P.
2012-01-01
Stirred-flow cell tests were carried out to investigate uranium (U) release from different size fractions of sediments from the U.S. Department of Energy’s Hanford 300 Area in Washington, USA. Results show that the measured concentration of U release varies with different size fractions, with the fine-grained mass fractions (<75 μm, 75–500 μm, and 500–2000 μm) being the main U carriers. However, because the sediment is mainly composed of gravel (2000–8000 μm) materials, the gravel fraction is a non-negligible U pool. Our elution experiments give a value of 8.7% of the total U being in the gravel fraction, significantly reducing the current uncertainty in evaluating U inventory. A log–log plot of released U concentration vs. elution volume (i.e., elution time) shows a power-law relationship for all size fractions, with identical exponents for the three fine size fractions (−0.875). For the <2000 μm mass fraction, comparing our eluted U values with reported total U concentrations, we estimate that a lower bound value 8.6% of the total uranium is labile. This compares well with the previously published value of 11.8% labile U after extraction with a dilute extractant for three weeks. - Highlights: ► Stirred-flow cells were used to study U release in Hanford 300 Area sediment. ► Fine-grained size fractions have higher U concentrations. ► U in coarse fraction is less studied, but its 8.7–9.3% of total U is non-negligible. ► A power-law relationship is observed between released U and elution volume. ► About 8.6% of U in the <2 mm sediment is labile.
Radon emanation fractions from concretes containing fly ash and metakaolin
International Nuclear Information System (INIS)
Taylor-Lange, Sarah C.; Juenger, Maria C.G.; Siegel, Jeffrey A.
2014-01-01
Radon ( 222 Rn) and progenies emanate from soil and building components and can create an indoor air quality hazard. In this study, nine concrete constituents, including the supplementary cementitious materials (SCMs) fly ash and metakaolin, were used to create eleven different concrete mixtures. We investigated the effect of constituent radium specific activity, radon effective activity and emanation fraction on the concrete emanation fraction and the radon exhalation rate. Given the serious health effects associated with radionuclide exposure, experimental results were coupled with Monte Carlo simulations to demonstrate predictive differences in the indoor radon concentration due to concrete mixture design. The results from this study show that, on average, fly ash constituents possessed radium specific activities ranging from 100 Bq/kg to 200 Bq/kg and emanation fractions ranging from 1.1% to 2.5%. The lowest emitting concrete mixture containing fly ash resulted in a 3.4% reduction in the concrete emanation fraction, owing to the relatively low emanation that exists when fly ash is part of concrete. On average, the metakaolin constituents contained radium specific activities ranging from 67 Bq/kg to 600 Bq/kg and emanation fractions ranging from 8.4% to 15.5%, and changed the total concrete emanation fraction by roughly ± 5% relative to control samples. The results from this study suggest that SCMs can reduce indoor radon exposure from concrete, contingent upon SCM radionucleotide content and emanation fraction. Lastly, the experimental results provide SCM-specific concrete emanation fractions for indoor radon exposure modeling. - Highlights: • Fly ash or metakaolin SCMs can neutralize or reduce concrete emanation fractions. • The specific activity of constituents is a poor predictor of the concrete emanation fraction. • Exhalation from fly ash concretes represents a small fraction of the total indoor radon concentration
What next in fractionated radiotherapy
International Nuclear Information System (INIS)
Fowler, J.F.
1984-01-01
Trends in models for predicting the total dose required to produce tolerable normal-tissue injury can be seen by the progression from the ''cube root law'', through Strandqvist's slope of 0.22, to NSD, TDF and CRE which have separate time and fraction number exponents, to even better approximations now available. The dose-response formulae that can be used to define the effect of fraction size (and number) include (1) the linear quadratic (LQ) model (2) the two-component (TC) multi-target model and (3) repair-misrepair models. The LQ model offers considerable convenience, requires only two parameters to be determined, and emphasizes the difference between late and early normal-tissue dependence on dose per fraction first shown by exponents greater than the NSD slope of 0.24. Exponents of overall time, e.g. Tsup(0.11), yield the wrong shape of time curve, suggesting that most proliferating occurs early, although it really occurs after a delay depending on the turnover time of the tissue. Improved clinical results are being sought by hyperfractionation, accelerated fractionation, or continuous low dose rate irradiation as in interstitial implants. (U.K.)
Thallium in fractions of sediments formed during the 2004 tsunami in Thailand.
Lukaszewski, Zenon; Karbowska, Bozena; Zembrzuski, Wlodzimierz; Siepak, Marcin
2012-06-01
Thallium is a highly toxic element. Its concentration in sediment fractions from the 2004 tsunami in Thailand was investigated. A modified BCR procedure was used for sequential extraction. Tl was determined by flow injection differential pulse anodic stripping voltammetry. It was found that the majority of thallium in the investigated tsunami sediments (86-97 percent) is entrapped in the alumosilicate parent matter i.e. it is entirely immovable. Only the total destruction of this residual fraction with hydrofluoric acid made this thallium available. The conclusion strongly supports the hypothesis that thallium is mainly entrapped in alumosilicate parent matter. Total thallium concentration in the investigated tsunami sediments was divergent in various samples from 0.37 to 1.13 μg g(-1) and significantly different from the reference area (0.05 μg g(-1)). Tsunami sediment fractions from different sampling points are divergent in terms of total thallium concentration and concentration of mobile thallium. Generally, mobile thallium concentration was growing in sequence: water soluble fractionthallium concentration in the reducible fraction was higher than in the oxidizable fraction. Copyright © 2012 Elsevier Inc. All rights reserved.
Jin, Jie; Sun, Ke; Liu, Wei; Li, Shiwei; Peng, Xianqiang; Yang, Yan; Han, Lanfang; Du, Ziwen; Wang, Xiangke
2018-05-01
Chemical composition and pollutant sorption of biochar-derived organic matter fractions (BDOMs) are critical for understanding the long-term environmental significance of biochar. Phenanthrene (PHE) sorption by the humic acid-like (HAL) fractions isolated from plant straw- (PLABs) and animal manure-based (ANIBs) biochars, and the residue materials (RES) after HAL extraction was investigated. The HAL fraction comprised approximately 50% of organic carbon (OC) of the original biochars. Results of XPS and 13 C NMR demonstrated that the biochar-derived HAL fractions mainly consisted of aromatic clusters substituted by carboxylic groups. The CO 2 cumulative surface area of BDOMs excluding PLAB-derived RES fractions was obviously lower than that of corresponding biochars. The sorption nonlinearity of PHE by the fresh biochars was significantly stronger than that of the BDOM fractions, implying that the BDOM fractions were more chemically homogeneous. The BDOMs generally exhibited comparable or higher OC-normalized distribution coefficients (K oc ) of PHE than the original biochars. The PHE logK oc values of the fresh biochars correlated negatively with the micropore volumes due to steric hindrance effect. In contrast, a positive relationship between the sorption coefficients (K d ) of BDOMs and the micropore volumes was observed in this study, suggesting that pore filling could dominate PHE sorption by the BDOMs. The positive correlation between the PHE logK oc values of the HAL fractions and the aromatic C contents indicates that PHE sorption by the HAL fractions was regulated by aromatic domains. The findings of this study improve our knowledge of the evolution of biochar properties after application and its potential environmental impacts. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wu, Ning-Hua; Ke, Zhi-Qiang; Wu, Shan; Yang, Xiao-Song; Chen, Qing-Jie; Huang, Sheng-Tang; Liu, Chao
2018-04-10
Lysimachia christinae Hance is a traditional Chinese medicine with diuretic, detumescent, and detoxifying effects. Our aimed to optimize the extraction protocol to maximize the yield of flavonoids from Lysimachia christinae Hance, and evaluate the pharmacological activities of four fractions, namely, petroleum ether (PE), ethyl acetate (EA), n-butanol (NB), and aqueous (AQ) fractions, of the ethanolic extract of Lysimachia christinae Hance. The flavonoid monomers in the crude extract were characterized via high performance liquid chromatography (HPLC), were used as markers for extract quality control and standardization. The total flavonoid, total phenolic, and total polysaccharide contents of each fraction were determined by spectrophotometry. Further, the in vitro free radical (diphenylpicrylhydrazyl, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid), superoxide, and hydroxyl radicals) scavenging activities, and antioxidant capacity in endothelial cells were evaluated for each fraction. After optimizing the extraction protocol to maximize the total flavonoid yield from L. christinae Hance, the NB fractions had the highest total flavonoid (39.4 ± 4.55 mg RE/g), total phenolic (41.1 ± 3.07 mg GAE/g) and total polysaccharide (168.1 ± 7.07 mg GE/g); In addition, the NB fraction of the ethanolic extract of L. christinae Hance reveal the strongest radical-scavenging activity, antioxidant activity and protective effects against H 2 O 2 -induced injury in HUVECs. Among the four fractions of L. christinae Hance, the NB fraction showed the most potent antioxidant and endothelial protective effects, which may be attributed to its high flavonoid, phenolic contents and optimal portfolio of different active ingredients of NB fractions of the ethanolic extract of L. christinae Hance. This study might improve our understanding of the pharmacological activities of L. christinae Hance, thereby facilitating its use in disease prevention and treatment.
Directory of Open Access Journals (Sweden)
Claisa Andréa Silva de Freitas
2006-10-01
Full Text Available As frutas tropicais são muito aceitas pelos consumidores, e são importantes fontes de componentes antioxidantes. A acerola, conhecida por conter grandes quantidades de vitamina C, é também rica em antocianinas e carotenóides. O presente trabalho teve por objetivo avaliar a estabilidade dos carotenóides totais, antocianinas totais e vitamina C do suco tropical de acerola adoçado, elaborado pelos processos Hot Fill (garrafas de vidro e asséptico (embalagens cartonadas, durante 350 dias de armazenamento em condições similares às de comercialização (28ºC ± 2ºC. Ao final do experimento observou-se que não houve perdas de antocianinas totais para o processo Hot Fill, no entanto, para o processo asséptico constatou-se uma redução de 86,89% dos teores iniciais. Os valores de carotenóides totais permaneceram inalterados nas amostras do processo asséptico, enquanto nas do Hot Fill houve uma redução de 12,5%. Constatou-se redução nos teores de vitamina C da ordem de 23,61% para o processo Hot Fill e de 35,95% para o processo asséptico.Tropical fruits are widely accepted by consumers, and important sources of antioxidant compounds. Acerola, known to have high vitamin C levels, is also rich in anthocyanins and carotenoids. The purpose of this work was to evaluate the stability of the total carotenoids, total anthocyanins and ascorbic acid of the acerola sweetened tropical juice produced by the Hot Fill (glass bottles and aseptic (packings carton process during 350 days of storage in similar conditions of trade (28ºC ± 2ºC. It was observed that there were not losses of total anthocyanins for the process Hot Fill, however for the aseptic process a reduction of 86.89% of the initial values was observed. The values of total corotenoids stayed unaffected in the samples of the aseptic process, while in the one of the Hot Fill there was a reduction of 12.5%. A reduction in the values of ascorbic acid of 23.61% was observed for the Hot
Mode-based microparticle conveyor belt in air-filled hollow-core photonic crystal fiber.
Schmidt, Oliver A; Euser, Tijmen G; Russell, Philip St J
2013-12-02
We show how microparticles can be moved over long distances and precisely positioned in a low-loss air-filled hollow-core photonic crystal fiber using a coherent superposition of two co-propagating spatial modes, balanced by a backward-propagating fundamental mode. This creates a series of trapping positions spaced by half the beat-length between the forward-propagating modes (typically a fraction of a millimeter). The system allows a trapped microparticle to be moved along the fiber by continuously tuning the relative phase between the two forward-propagating modes. This mode-based optical conveyor belt combines long-range transport of microparticles with a positional accuracy of 1 µm. The technique also has potential uses in waveguide-based optofluidic systems.
Safety Distances for hydrogen filling stations
Energy Technology Data Exchange (ETDEWEB)
Matthijsen, A. J. C. M.; Kooi, E. S.
2005-07-01
In the Netherlands there is a growing interest in using natural gas as a transport fuel. The most important drivers behind this development are formed by poor inner city air quality and the decision to close several LPG filling stations. Dwellings are not allowed within the safety distances of 45 or 110 meters from the tanker filling point of these LPG stations, depending on the capacity of the station. Another driver is global warming. We are carrying out a study on station supply, compression, storage and filling for natural gas stations, and a similar, simultaneous study on hydrogen as a followup to our risk analysis for the hydrogen filling station in Amsterdam. Here, three buses drive on hydrogen as part of the European CUTE project. Driving on natural gas is an important step in the transition to cars on hydrogen. This study was commissioned by the Dutch Ministry of Spatial Planning, Housing and the Environment to advise on external safety aspects of future hydrogen filling stations. According to Dutch law homes may not be built within an individual risk contour of 10-6 per year of a dangerous object, such as a plant with hazardous materials or a filling station. An individual risk contour of 10-6 is represented by a line around a dangerous object that connects locations with an individual risk level of 10-6 per year. An individual 'located' within this contour line has a chance of one per million per year or more to be killed as a result of an accident caused by this object. The longest distance between the object and such a contour is called a 'safety distance'. A study on safety distances is now in progress for different kinds of hydrogen filling stations (e. g. gaseous and liquid hydrogen) and for different capacities, such as big, medium and small stations. The focus is on different kinds of hydrogen production and the hydrogen supply of the filling station. To decide on the design and supply of the hydrogen station, we examined the
Pagel, Paul S; Dye, Lonnie; Boettcher, Brent T; Freed, Julie K
2018-03-07
Blood flow across the mitral valve during early left ventricular (LV) filling produces a 3-dimensional rotational fluid body, known as a vortex ring, that enhances LV filling efficiency. Diastolic dysfunction is common in elderly patients, but the influence of advanced age on vortex formation is unknown. The authors tested the hypothesis that advanced age is associated with a reduction in LV filling efficiency quantified using vortex formation time (VFT) in octogenarians undergoing coronary artery bypass graft (CABG) surgery. Observational study. Veterans Affairs medical center. After institutional review board approval, octogenarians (n = 7; 82 ± 2 year [mean ± standard deviation]; ejection fraction 56% ± 7%) without valve disease or atrial arrhythmias undergoing CABG were compared with a younger cohort (n = 7; 55 ± 6 year; ejection fraction 57% ± 7%) who were undergoing coronary revascularization. None. All patients were monitored using radial and pulmonary arterial catheters and transesophageal echocardiography. Peak early LV filling (E) and atrial systole (A) blood flow velocities and their corresponding velocity-time integrals were obtained using pulse-wave Doppler echocardiography to determine E/A, atrial filling fraction (β), and E wave deceleration time. Pulse-wave Doppler also was used to measure pulmonary venous blood flow during systole and diastole. Mitral valve diameter (D) was calculated as the average of major and minor axis lengths obtained in the midesophageal LV bicommissural and long-axis transesophageal echocardiography imaging planes, respectively. VFT was calculated as 4 × (1 - β) × SV/(πD 3 ), where SV is the stroke volume measured using thermodilution. Systemic and pulmonary hemodynamics, LV diastolic function, and VFT were determined during steady-state conditions 30 minutes before cardiopulmonary bypass. A delayed relaxation pattern of LV filling (E/A 0.81 ± 0.16 v 1.29 ± 0.19, p = 0.00015; β 0.44 ± 0.05 v 0.35 ± 0.03, p = 0
Fractional vector calculus for fractional advection dispersion
Meerschaert, Mark M.; Mortensen, Jeff; Wheatcraft, Stephen W.
2006-07-01
We develop the basic tools of fractional vector calculus including a fractional derivative version of the gradient, divergence, and curl, and a fractional divergence theorem and Stokes theorem. These basic tools are then applied to provide a physical explanation for the fractional advection-dispersion equation for flow in heterogeneous porous media.
Maximizing Tumor Immunity With Fractionated Radiation
International Nuclear Information System (INIS)
Schaue, Dörthe; Ratikan, Josephine A.; Iwamoto, Keisuke S.; McBride, William H.
2012-01-01
Purpose: Technologic advances have led to increased clinical use of higher-sized fractions of radiation dose and higher total doses. How these modify the pathways involved in tumor cell death, normal tissue response, and signaling to the immune system has been inadequately explored. Here we ask how radiation dose and fraction size affect antitumor immunity, the suppression thereof, and how this might relate to tumor control. Methods and Materials: Mice bearing B16-OVA murine melanoma were treated with up to 15 Gy radiation given in various-size fractions, and tumor growth followed. The tumor-specific immune response in the spleen was assessed by interferon-γ enzyme-linked immunospot (ELISPOT) assay with ovalbumin (OVA) as the surrogate tumor antigen and the contribution of regulatory T cells (Tregs) determined by the proportion of CD4 + CD25 hi Foxp3 + T cells. Results: After single doses, tumor control increased with the size of radiation dose, as did the number of tumor-reactive T cells. This was offset at the highest dose by an increase in Treg representation. Fractionated treatment with medium-size radiation doses of 7.5 Gy/fraction gave the best tumor control and tumor immunity while maintaining low Treg numbers. Conclusions: Radiation can be an immune adjuvant, but the response varies with the size of dose per fraction. The ultimate challenge is to optimally integrate cancer immunotherapy into radiation therapy.
Effects of selective attention on perceptual filling-in.
De Weerd, P; Smith, E; Greenberg, P
2006-03-01
After few seconds, a figure steadily presented in peripheral vision becomes perceptually filled-in by its background, as if it "disappeared". We report that directing attention to the color, shape, or location of a figure increased the probability of perceiving filling-in compared to unattended figures, without modifying the time required for filling-in. This effect could be augmented by boosting attention. Furthermore, the frequency distribution of filling-in response times for attended figures could be predicted by multiplying the frequencies of response times for unattended figures with a constant. We propose that, after failure of figure-ground segregation, the neural interpolation processes that produce perceptual filling-in are enhanced in attended figure regions. As filling-in processes are involved in surface perception, the present study demonstrates that even very early visual processes are subject to modulation by cognitive factors.
Measurement of the real time fill-pattern at the Australian Synchrotron
International Nuclear Information System (INIS)
Peake, D.J.; Boland, M.J.; LeBlanc, G.S.; Rassool, R.P.
2008-01-01
This article describes the development, commissioning and operation of a Fill-Pattern Monitor (FPM) for the Australian Synchrotron that measures the real-time intensity distribution of the electron bunches in the storage ring. Using a combination of an ultra-fast photodiode and a high-speed digitiser, real-time measurement of the fill-pattern at bunch-by-bunch resolution was achieved. The results compare very well with current methods of measuring the fill-pattern, such as a pick-up style detector. In addition, the FPM is fully integrated into the EPICS control system. The data provided by the FPM gives accurate RF bucket position and relative bunch currents over a wide range of stored beam currents, from 0.01 mA in a single bunch to 200 mA total beam current. The FPM monitors the success of an injection attempt into the storage ring and is used in a feedback loop to determine where to target the next injection. Using the FPM a beam top-up mode was successfully tested, resulting in a near constant beam current by periodic targeted injections over an 8 h shift. Results are presented for dynamically topped up real-time injection, where the beam pattern was squared using an intensity-dependent injection algorithm
Efficiency of polymerization of bulk-fill composite resins: a systematic review.
Reis, André Figueiredo; Vestphal, Mariana; Amaral, Roberto Cesar do; Rodrigues, José Augusto; Roulet, Jean-François; Roscoe, Marina Guimarães
2017-08-28
This systematic review assessed the literature to evaluate the efficiency of polymerization of bulk-fill composite resins at 4 mm restoration depth. PubMed, Cochrane, Scopus and Web of Science databases were searched with no restrictions on year, publication status, or article's language. Selection criteria included studies that evaluated bulk-fill composite resin when inserted in a minimum thickness of 4 mm, followed by curing according to the manufacturers' instructions; presented sound statistical data; and comparison with a control group and/or a reference measurement of quality of polymerization. The evidence level was evaluated by qualitative scoring system and classified as high-, moderate- and low- evidence level. A total of 534 articles were retrieved in the initial search. After the review process, only 10 full-text articles met the inclusion criteria. Most articles included (80%) were classified as high evidence level. Among several techniques, microhardness was the most frequently method performed by the studies included in this systematic review. Irrespective to the "in vitro" method performed, bulk fill RBCs were partially likely to fulfill the important requirement regarding properly curing in 4 mm of cavity depth measured by depth of cure and / or degree of conversion. In general, low viscosities BFCs performed better regarding polymerization efficiency compared to the high viscosities BFCs.
Feasibility of fractionating MIBI cold kits for cost reduction
Energy Technology Data Exchange (ETDEWEB)
Penglis, S.; Tsopelas, C. [Royal Adelaide Hospital. SA (Australia)
1998-06-01
Full text: Recently {sup 99m}Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of {sup 99m}Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N{sub 2} atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation
Feasibility of fractionating MIBI cold kits for cost reduction
International Nuclear Information System (INIS)
Penglis, S.; Tsopelas, C.
1998-01-01
Full text: Recently 99m Tc-MIBI become the first 99mTc-labelled myocardial perfusion imaging agent commercially available in Australia. After labelling each vial is sufficient for three to four patient doses. However, it becomes very expensive when only a single patient dose is required (up to $350 per dose). Our goal in this study was to subdivide the MIBI kit into fractions to establish the stability of these split kits. If successful, this would reduce the expense and make the product more cost-effective. After dissolving the Iyophilised ingredients of a MIBI vial with 5 mL of N2-purged normal saline, 1 mL aliquots of the resultant solution were dispensed into N2-filled vials under aseptic conditions. The vials were then stored frozen at -70 deg C. 99mTc-MIBI was prepared by the addition of 2 GBq of 99m Tc-pertechnetate in I mL of normal saline to the fractionated kit, followed by heating at 100 deg C for 10 minutes at 0, 2, 4 and 8 weeks post-fractionation. The product was allowed to cool before testing for radiochemical purity (RCP) for up to six hours post-labelling. The RCP of each vial was determined using aluminium oxide coated aluminium TLC strips (Merck) run in 100% ethanol. Over the eight-week evaluation period RCP was maintained at 94.2 + 1.3% over six hours (n = 16), which is greater than the minimum recommended RCP (90%) for patient use. These results show that fractionation of MIBI cold kits and sub-frozen storage under an N 2 atmosphere provides a stable and economical multidose product. Using this method the cost of a single patient dose can be reduced considerably from $350, even allowing for the labour involved in the fractionation
Carlier, Thomas; Willowson, Kathy P; Fourkal, Eugene; Bailey, Dale L; Doss, Mohan; Conti, Maurizio
2015-07-01
(90)Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with (90)Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging (90)Y and to compare experimental results with clinical data from two types of commercially available (90)Y microspheres. Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of (90)Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a (90)Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere(®) and 24 with SIR-Spheres(®)) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms
International Nuclear Information System (INIS)
Carlier, Thomas; Willowson, Kathy P.; Fourkal, Eugene; Bailey, Dale L.; Doss, Mohan; Conti, Maurizio
2015-01-01
Purpose: 90 Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with 90 Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging 90 Y and to compare experimental results with clinical data from two types of commercially available 90 Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of 90 Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a 90 Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere ® and 24 with SIR-Spheres ® ) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for
Fractional vector calculus and fractional Maxwell's equations
International Nuclear Information System (INIS)
Tarasov, Vasily E.
2008-01-01
The theory of derivatives and integrals of non-integer order goes back to Leibniz, Liouville, Grunwald, Letnikov and Riemann. The history of fractional vector calculus (FVC) has only 10 years. The main approaches to formulate a FVC, which are used in the physics during the past few years, will be briefly described in this paper. We solve some problems of consistent formulations of FVC by using a fractional generalization of the Fundamental Theorem of Calculus. We define the differential and integral vector operations. The fractional Green's, Stokes' and Gauss's theorems are formulated. The proofs of these theorems are realized for simplest regions. A fractional generalization of exterior differential calculus of differential forms is discussed. Fractional nonlocal Maxwell's equations and the corresponding fractional wave equations are considered
Gammie, A; Abrams, P; Bevan, W; Ellis-Jones, J; Gray, J; Hassine, A; Williams, J; Hashim, H
2016-11-01
This study aimed to evaluate whether the pressure readings obtained from air-filled catheters (AFCs) are the same as the readings from simultaneously inserted water-filled catheters (WFCs). It also aimed to make any possible recommendations for the use of AFCs to conform to International Continence Society (ICS) Good Urodynamic Practices (GUP). Female patients undergoing urodynamic studies in a single center had water-filled and air-filled catheters simultaneously measuring abdominal and intravesical pressure during filling with saline and during voiding. The pressures recorded by each system at each event during the test were compared using paired t-test and Bland-Altman analyses. 62 patients were recruited, of whom 51 had pressures that could be compared during filling, and 23 during voiding. On average, the pressures measured by the two systems were not significantly different during filling and at maximum flow, but the values for a given patient were found to differ by up to 10 cmH 2 O. This study shows that AFCs and WFCs cannot be assumed to register equal values of pressure. It has further shown that even when the p det readings are compared with their value at the start of a test, a divergence of values of up to 10 cmH 2 O remains. If AFCs are used, care must be taken to compensate for any p det variations that occur during patient movement. Before AFCs are adopted, new normal values for resting pressures need to be developed to allow good quality AFC pressure readings to be made. Neurourol. Urodynam. 35:926-933, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
DEFF Research Database (Denmark)
Møller, L; Wenzel, A; Wegge-Larsen, AM
2013-01-01
-section images from Micro-computed Tomography scans. Results. All root canal fillings had voids. Permutation test showed no statistically significant difference between the two root filling techniques in relation to presence of voids (p = 0.092). A statistically significant difference in obturation time between...
Fractionation study: survival of mouse intestinal crypts to exposure of 60Co and 11 MeV electrons
International Nuclear Information System (INIS)
Coffey, C.W.
1975-01-01
The study was conducted to determine a statistical procedure for the quantification of time, dose, fraction relations for mouse intestinal crypt survival after fractionated Co-60 and 11-MeV electron irradiation. In the initial phase of the investigation CDF/1 male mice were exposed to fractionated Co-60 irradiation. A completely randomized experimental design with three factors, total time from initiation to completion of fractionation schedule, number of fractions, and total dose was utilized. The experimental animals were irradiated with a Co-60 panoramic irradiator unit at an absorbed dose rate of approximately 51 rads per minute. Two days after completion of the fractionation schedule, the experimental animals were sacrificed by cervical dislocation. Sections of intestinal jejunum were resected and routine histological preparations performed. The surviving crypts were scored with a compound microscope using a quantitative counting technique. The resulting crypt survival was observed to increase for increasing total times and fraction numbers
Fractional Number Operator and Associated Fractional Diffusion Equations
Rguigui, Hafedh
2018-03-01
In this paper, we study the fractional number operator as an analog of the finite-dimensional fractional Laplacian. An important relation with the Ornstein-Uhlenbeck process is given. Using a semigroup approach, the solution of the Cauchy problem associated to the fractional number operator is presented. By means of the Mittag-Leffler function and the Laplace transform, we give the solution of the Caputo time fractional diffusion equation and Riemann-Liouville time fractional diffusion equation in infinite dimensions associated to the fractional number operator.
Selective filling of Photonic Crystal Fibres
DEFF Research Database (Denmark)
Nielsen, Kristian; Noordegraaf, Danny; Sørensen, Thorkild
2005-01-01
A model for calculating the time necessary for filling one or more specific holes in a photonic crystal fibre is made. This model is verified for water, and its enabling potential is illustrated by a polymer application. Selective filling of the core in an air-guide photonic crystal fibre...
A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation
International Nuclear Information System (INIS)
Brydsten, Lars
2004-05-01
with 4.1% wave-washed sand. Using time steps of 100 years, the sedimentation of inorganic material was then added according to the inorganic basin filling rate equation and the growth of vegetation using the choke-up rate. Growth of vegetation was only permitted on bottom areas shallower than 2 meters water depth. The model was then iterated until the former lake basin was totally filled with material. The model was then used to predict the ontogeny of two future lakes, the 'New Small Lake' and the 'New Large Lake' situated close to the existing store for radioactive waste, SFR-1. According to the model, The 'New Small Lake' will be completely filled with sediments and vegetation some 2500 years after isolation, while the 'New Large Lake' will be completely filled 4000 years after isolation
A mathematical model for lake ontogeny in terms of filling with sediments and macrophyte vegetation
Energy Technology Data Exchange (ETDEWEB)
Brydsten, Lars [Umeaa Univ. (Sweden). Dept. of Biology and Environmental Science
2004-05-01
with 4.1% wave-washed sand. Using time steps of 100 years, the sedimentation of inorganic material was then added according to the inorganic basin filling rate equation and the growth of vegetation using the choke-up rate. Growth of vegetation was only permitted on bottom areas shallower than 2 meters water depth. The model was then iterated until the former lake basin was totally filled with material. The model was then used to predict the ontogeny of two future lakes, the 'New Small Lake' and the 'New Large Lake' situated close to the existing store for radioactive waste, SFR-1. According to the model, The 'New Small Lake' will be completely filled with sediments and vegetation some 2500 years after isolation, while the 'New Large Lake' will be completely filled 4000 years after isol0010at.
Effects of exotic plantation forests on soil edaphon and organic matter fractions.
Xu, Gang; Liu, Yao; Long, Zhijian; Hu, Shanglian; Zhang, Yuanbin; Jiang, Hao
2018-06-01
There is uncertainty and limited knowledge regarding soil microbial properties and organic matter fractions of natural secondary forest accompanying chemical environmental changes of replacement by pure alien plantation forests in a hilly area of southwest of Sichuan province China. The aim of this study was to evaluate the impact of natural secondary forest (NSF) to pure Cryptomeria fortunei forest (CFF) and Cunninghamia lanceolata forest (CLF) on soil organic fractions and microbial communities. The results showed that the soil total phospholipid fatty acids (PLFAs), total bacteria and fungi, microbial carbon pool, organic recalcitrant carbon (C) and (N) fractions, soil microbial quotient and labile and recalcitrant C use efficiencies in each pure plantation were significantly decreased, but their microbial N pool, labile C and N pools, soil carbon dioxide efflux, soil respiratory quotient and recalcitrant N use efficiency were increased. An RDA analysis revealed that soil total PLFAs, total bacteria and fungi and total Gram-positive and Gram-negative bacteria were significantly associated with exchangeable Al 3+ , exchangeable acid, Al 3+ , available P and Mg 2+ and pH, which resulted into microbial functional changes of soil labile and recalcitrant substrate use efficiencies. Modified microbial C- and N-use efficiency due to forest conversion ultimately meets those of rapidly growing trees in plantation forests. Enlarged soil labile fractions and soil respiratory quotients in plantation forests would be a potential positive effect for C source in the future forest management. Altogether, pure plantation practices could provoke regulatory networks and functions of soil microbes and enzyme activities, consequently leading to differentiated utilization of soil organic matter fractions accompanying the change in environmental factors. Copyright © 2018 Elsevier B.V. All rights reserved.
Fractional Processes and Fractional-Order Signal Processing Techniques and Applications
Sheng, Hu; Qiu, TianShuang
2012-01-01
Fractional processes are widely found in science, technology and engineering systems. In Fractional Processes and Fractional-order Signal Processing, some complex random signals, characterized by the presence of a heavy-tailed distribution or non-negligible dependence between distant observations (local and long memory), are introduced and examined from the ‘fractional’ perspective using simulation, fractional-order modeling and filtering and realization of fractional-order systems. These fractional-order signal processing (FOSP) techniques are based on fractional calculus, the fractional Fourier transform and fractional lower-order moments. Fractional Processes and Fractional-order Signal Processing: • presents fractional processes of fixed, variable and distributed order studied as the output of fractional-order differential systems; • introduces FOSP techniques and the fractional signals and fractional systems point of view; • details real-world-application examples of FOSP techniques to demonstr...
[Cermet cements for milk tooth fillings. Preliminary results].
Hickel, R; Petschelt, A; Voss, A
1989-06-01
106 Ketac-Silver fillings in deciduous molars were reevaluated after 1 to 3.3 years, i.e. 25 month on the average. About 90% of 50 occlusal fillings and about 84% of 56 multisurface restorations were unchanged. Without claiming statistical evidence for their conclusiveness, we consider these results as an indication that cermet cements are a useful alternative to amalgam fillings in deciduous teeth, particularly since the life of these fillings is limited to the time until the milk tooth is physiologically lost.
International Nuclear Information System (INIS)
Steinhauer, L. C.; Kimura, W. D.
2006-01-01
We have developed a 1-D, quasi-steady-state numerical model for a gas-filled capillary discharge that is designed to aid in selecting the optimum capillary radius in order to guide a laser beam with the required intensity through the capillary. The model also includes the option for an external solenoid B-field around the capillary, which increases the depth of the parabolic density channel in the capillary, thereby allowing for propagation of smaller laser beam waists. The model has been used to select the parameters for gas-filled capillaries to be utilized during the Staged Electron Laser Acceleration -- Laser Wakefield (STELLA-LW) experiment
International Nuclear Information System (INIS)
Itoh, Satoshi; Inomata, Taisuke; Ogawa, Yasuhiro; Yoshida, Shoji; Sonobe, Hiroshi; Ohtsuki, Yuji
1999-01-01
The purpose of this study is to determine serial histopathological differences in guinea pig lungs receiving the same total dose as clinically used between conventional fractionated and hyperfractionated irradiation. The guinea pigs received 80 Gy in 40 daily fractions of 2 Gy each (conventional fractionation), 80 Gy in 80 fractions of 1 Gy each twice a day (hyperfractionation), 81 Gy in 27 daily fractions of 3 Gy each (conventional fractionation), or 81 Gy in 54 fractions of 1.5 Gy each twice a day (hyperfractionation). We evaluated the histopathological changes of irradiated guinea pig lungs at 1, 2, 3, 6, 9, and 12 months after irradiation. The guinea pig lungs that received 81 Gy in 27 daily fractions showed histopathological changes of inflammation including formation of lymph follicles after 6 months. The lungs which received 81 Gy in 54 fractions showed similar but slightly less pronounced changes than those that received 81 Gy in 27 daily fractions. The guinea pig lungs of other groups showed no histopathological changes during the observation period. In hyperfractionated irradiation the damage to the guinea pig lung is quantitatively less than that occurring as a result of conventional fractionated irradiation of the same total dose. (author)
Energy Technology Data Exchange (ETDEWEB)
Itoh, Satoshi; Inomata, Taisuke; Ogawa, Yasuhiro; Yoshida, Shoji; Sonobe, Hiroshi; Ohtsuki, Yuji [Kochi Medical School, Nankoku (Japan)
1999-05-01
The purpose of this study is to determine serial histopathological differences in guinea pig lungs receiving the same total dose as clinically used between conventional fractionated and hyperfractionated irradiation. The guinea pigs received 80 Gy in 40 daily fractions of 2 Gy each (conventional fractionation), 80 Gy in 80 fractions of 1 Gy each twice a day (hyperfractionation), 81 Gy in 27 daily fractions of 3 Gy each (conventional fractionation), or 81 Gy in 54 fractions of 1.5 Gy each twice a day (hyperfractionation). We evaluated the histopathological changes of irradiated guinea pig lungs at 1, 2, 3, 6, 9, and 12 months after irradiation. The guinea pig lungs that received 81 Gy in 27 daily fractions showed histopathological changes of inflammation including formation of lymph follicles after 6 months. The lungs which received 81 Gy in 54 fractions showed similar but slightly less pronounced changes than those that received 81 Gy in 27 daily fractions. The guinea pig lungs of other groups showed no histopathological changes during the observation period. In hyperfractionated irradiation the damage to the guinea pig lung is quantitatively less than that occurring as a result of conventional fractionated irradiation of the same total dose. (author)
van Zyl, S P; Gulabivala, K; Ng, Y-L
2005-09-01
(i) To compare the prevalence of extrusion of root filling material when placed using different root filling techniques, with or without customization of the master gutta-percha (GP) cone; and (ii) to investigate the effects of some factors influencing root filling extrusion and presence of voids. A total of 180 roots were selected, prepared and randomly allocated to three groups. Five general dental practitioners performed the root fillings; each filled one group of roots (n = 60) using each of three techniques; 'cold lateral compaction' (n = 20), 'warm vertical compaction' (n = 20) and 'continuous-wave' (n = 20) techniques. For each obturation technique, the master GP cone was customized using chloroform in 10 samples. Two groups of the roots were recycled to allow all five operators to fulfill their remit. Two observers, blind to operator and obturation technique, examined the radiographs (master apical file, post-obturation) to determine the presence of root filling extrusion and voids within the apical 5 mm, independently. Root filling extrusion was also confirmed by direct inspection of the root apex after obturation. The data were analysed using logistic regression models. A total of 300 root fillings were performed; nine were excluded from the analysis. Most of the root fillings (80%, n = 233) were placed within 0.5 mm of the working length; only 20% (n = 58) were placed >0.5 mm beyond the working length. The odds of prevalence of extrusion (>0.5 mm) were significantly reduced by about 50% when cold lateral compaction or customization of GP were used. One operator produced 2.5 times more extruded root fillings than others. Curvature & length of root canal, apical size of prepared canal, as well as operator's preferred obturation technique had no significant influence on the prevalence of extrusion. Customization of GP was the sole factor to significantly reduce the prevalence of voids within the apical 5 mm of working length. Root filling extrusion was
Fractionation and characterization of soil organic carbon during transition to organic farming
Abdelrahman, H.; Olk, D.; Cocozza, C.; Miano, T.
2012-04-01
The transition from conventional to organic farming is the most difficult period faced by organic growers as it could be characterized by unstable conditions, such as nutrient availability, production reductions, mineralization extents. As soil organic matter (SOM), specifically soil organic carbon (SOC), is known to play important roles in maintenance and improvement of many soil properties, it is important to define its changes during the transition period. Total SOC might not be the suitable tool to track the changes in organically based soil fertility within a 3- to 5-yr transition period. Labile fractions that are important for nutrient cycling and supply are likely to be controlled by management to a much greater extent than is total SOM. Two field experiments, in south of Italy, were established in 2009 to study the changes in SOC during transition to organic farming. Experiments included a cereal/leguminous rotation with triplicates treatments of permitted amendments (compost and fertilizers). Soils were sampled at the beginning of the project, and after each crop harvest in 2010 and 2011. A sequential fractionation procedure was used to separate different SOC-fractions: light fraction (LF), two size classes of particulate organic matter (POM), mobile humic acid (MHA) and Ca++ bound humic acid (CaHA). Isolated fractions were quantified and analyzed for their content of C, N, carbohydrates and amino compounds fingerprints. The obtained results showed that compost application contributed to significantly higher quantities of LF, POM and MHA than did fertilizers application. Carbohydrates content decreased in LF while increased noticeably in POM and slightly in MHA fractions, which indicates that decomposing materials are converted, within the time span of humification, from young fractions into more mature fractions. Amino compounds were found to provide up to 40% of total soil N with a major contribution of the humified fractions, MHA and CaHA. The utilized
Initial settlements of rock fills on soft clay
Pedersen, Truls Martens
2012-01-01
Rock fills that hit the seabed will remold the underlying material. If this material is a clay with sufficiently low shear strength, it will adopt rheological properties, causing flow through the rock fill, and contributing to the initial settlements of the rock fill in addition to conventional consolidation theory. The settlements of the rocks depend upon the height of the rock fill and how the rocks have been laid out. This is due to the viscosity of the clay, and the fact that clay is thix...
Dose rate and fractionation: Relative importance in radiation for bone marrow transplantation
International Nuclear Information System (INIS)
Tarbell, N.J.; Rosenblatt, M.; Mauch, P.; Hellman, S.
1987-01-01
The optimal dose rate and fractionation schedules for total body irradiation (TBI) in bone marrow transplantation (BMT) are presently unknown. This study compares several fractionation and dose rate schedules that are currently in clinical use. C/sub 3/H/HeJ were given TBI and the bone marrow survival fraction was calculated using the CFU's assay. Irradiation was given as low dose rate (LDR) at 5 cGy/min or high dose rate (HDR) at 80 cGy/min, in single fraction (SF) and fractionated (FX) regimens. These results indicate no increase in survival for the normal bone marrow stem cells with fractionation either at high or low dose-rates. In fact, fractionation seemed to decrease the bone marrow survival over single fraction radiation
Directory of Open Access Journals (Sweden)
Rodiansono Rodiansono
2010-06-01
Full Text Available Activity test and regeneration of NiMo/active natural zeolite catalyst for hydrocracking of waste plastic fraction of polyprophylene (PP type have been carried out. The catalysts was prepared by loading Mo followed by Ni Metals onto the natural zeolite (Z sample, then calcined at 500oC, oxidized and reduced at 400oC under nitrogen, oxygen and hydrogen stream, respectively. The characterization of catalysts including spesific surface area, average pore radius, and total pore volume were performed by gas sorption analyzer, amount of total acid sites was determined by gas sorption method, and acid site strength was confirmed by IR spectroscopy. The hydrocracking process was carried out in a semi-flow reactor system at 360 oC and catalyst:feed ratio 0.5 under hydrogen stream (150 mL/hour. The feed was vaporized from the pyrolisis reactor into the hydrocracking reactor. A liquid product was collected and analyzed by gas chromatography (GC and gas chromatography-mass spectroscopy (GC-MS. The characterization results showed that spesific surface area, average pore radius, and total pore volume of the Z sample decreased after loading of the Ni and Mo metals. Amount of total acid sites of the NiMo/Z catalyst was higher than that of the Z sample. The activity of NiMo/Z catalyst decreased after several continously runs. Its regeneration produced the NiMo/Z reg catalyst with similar activity and selectivity to the fresh catalyst (NiMo/Z. The activity of catalysts at the optimum condition followed the order of NiMo/Z reg>NiMo/Z>Z (conversion of hydrocarbon C>12 and NiMo/Z reg>NiMo/Z>Z (total yield of gasoline fraction. The selectivity of catalysts for C7-C8 product followed the order of Z>NiMo/Z>NiMo/Z reg. Keywords: activity, polyprophylene, catalyst, gasoline fraction.
International Nuclear Information System (INIS)
Sasaki, Takehito; Kamata, Rikisaburo; Urahashi, Shingo; Yamaguchi, Tetsuji.
1993-01-01
One hundred and sixty-nine cervical lymph node-metastases from head and neck squamous cell carcinomas treated with either even fractionation or uneven fractionation regimens were analyzed in the present investigation. Logistic multivariate regression analysis indicated that: type of fractionation (even vs uneven), size of metastases, T value of primary tumors, and total dose are independent variables out of 18 variables that significantly influenced the rate of tumor clearance. The data, with statistical bias corrected by the regression equation, indicated that the uneven fractionation scheme significantly improved the rate of tumor clearance for the same size of metastases, total dose, and overall time compared to the even fractionation scheme. Further analysis by a linear-quadratic cell survival model indicated that the clinical improvement by uneven fractionation might not be explained entirely by a larger dose per fraction. It is suggested that tumor cells irradiated with an uneven fractionation regimen might repopulate more slowly, or they might be either less hypoxic or redistributed in a more radiosensitive phase in the cell cycle than those irradiated with even fractionation. This conclusion is clearly not definite, but it is suitable, pending the results of further investigation. (author)
Root Extract and Fractions in Streptozotocin-Induced Diabetic Rats
African Journals Online (AJOL)
Purpose: To investigate the effect of total hydroalcohol root extract of Plumeria alba ... Methods: The effect of total hydroalcohol extract at 250 mg/kg and different fractions .... using technique of separation by precipitation in ... environmental conditions (temperature of 25 ± 2 ... tubes were tightly closed and homogenized for a.
Fabry-Perot Interferometry in the Integer and Fractional Quantum Hall Regimes
McClure, Douglas; Chang, Willy; Kou, Angela; Marcus, Charles; Pfeiffer, Loren; West, Ken
2011-03-01
We present measurements of electronic Fabry-Perot interferometers in the integer and fractional quantum Hall regimes. Two classes of resistance oscillations may be seen as a function of magnetic field and gate voltage, as we have previously reported. In small interferometers in the integer regime, oscillations of the type associated with Coulomb interaction are ubiquitous, while those consistent with single-particle Aharonov-Bohm interference are seen to co-exist in some configurations. The amplitude scaling of both types with temperature and device size is consistent with a theoretical model. Oscillations are further observed in the fractional quantum Hall regime. Here the dependence of the period on the filling factors in the constrictions and bulk of the interferometer can shed light on the effective charge of the interfering quasiparticles, but care is needed to distinguish these oscillations from those associated with integer quantum Hall states. We acknowledge funding from Microsoft Project Q and IBM.
Maximizing Tumor Immunity With Fractionated Radiation
Energy Technology Data Exchange (ETDEWEB)
Schaue, Doerthe, E-mail: dschaue@mednet.ucla.edu [Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA (United States); Ratikan, Josephine A.; Iwamoto, Keisuke S.; McBride, William H. [Department of Radiation Oncology, David Geffen School of Medicine at UCLA, Los Angeles, CA (United States)
2012-07-15
Purpose: Technologic advances have led to increased clinical use of higher-sized fractions of radiation dose and higher total doses. How these modify the pathways involved in tumor cell death, normal tissue response, and signaling to the immune system has been inadequately explored. Here we ask how radiation dose and fraction size affect antitumor immunity, the suppression thereof, and how this might relate to tumor control. Methods and Materials: Mice bearing B16-OVA murine melanoma were treated with up to 15 Gy radiation given in various-size fractions, and tumor growth followed. The tumor-specific immune response in the spleen was assessed by interferon-{gamma} enzyme-linked immunospot (ELISPOT) assay with ovalbumin (OVA) as the surrogate tumor antigen and the contribution of regulatory T cells (Tregs) determined by the proportion of CD4{sup +}CD25{sup hi}Foxp3{sup +} T cells. Results: After single doses, tumor control increased with the size of radiation dose, as did the number of tumor-reactive T cells. This was offset at the highest dose by an increase in Treg representation. Fractionated treatment with medium-size radiation doses of 7.5 Gy/fraction gave the best tumor control and tumor immunity while maintaining low Treg numbers. Conclusions: Radiation can be an immune adjuvant, but the response varies with the size of dose per fraction. The ultimate challenge is to optimally integrate cancer immunotherapy into radiation therapy.
Energy Technology Data Exchange (ETDEWEB)
Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))
1984-10-01
A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.
21 CFR 872.3820 - Root canal filling resin.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Root canal filling resin. 872.3820 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3820 Root canal filling resin. (a) Identification. A root canal filling resin is a device composed of material, such as methylmethacrylate, intended...
Construction of a test embankment using a sand-tire shred mixture as fill material.
Yoon, Sungmin; Prezzi, Monica; Siddiki, Nayyar Zia; Kim, Bumjoo
2006-01-01
Use of tire shreds in construction projects, such as highway embankments, is becoming an accepted way of beneficially recycling scrap tires. However, in the last decade there was a decline in the use of pure tire shreds as fill materials in embankment construction, as they are susceptible to fire hazards due to the development of exothermic reactions. Tire shred-sand mixtures, on the other hand, were found to be effective in inhibiting exothermic reactions. When compared with pure tire shreds, tire shred-sand mixtures are less compressible and have higher shear strength. However, the literature contains limited information on the use of tire shred-soil mixtures as a fill material. The objectives of this paper are to discuss and evaluate the feasibility of using tire shred-sand mixtures as a fill material in embankment construction. A test embankment constructed using a 50/50 mixture, by volume, of tire shreds and sand was instrumented and monitored to: (a) determine total and differential settlements; (b) evaluate the environmental impact of the embankment construction on the groundwater quality due to leaching of fill material; and (c) study the temperature variation inside the embankment. The findings in this research indicate that mixtures of tire shreds and sand are viable materials for embankment construction.
Directory of Open Access Journals (Sweden)
Taufan Bramantoro
2011-03-01
Full Text Available Background: Dental health services program implementation in Balongsari Public Health Center during three years, 2006 until 2008, have a high average ratio of filling treatment compared to tooth extraction treatment (1:1.79 as compared to the standard set by the Ministry of Health (1:1. Cost effectiveness analysis and quality of life is needed as a form of economic evaluation of costs incurred by the consequences or impacts of health care programs, especially dental filling and tooth extraction, use to help in supporting the process of policy making in health care. The objective of this study was to assess cost effectiveness analysis (CEA and quality of life (QoL on dental filling and extraction treatment in Public Health Center. Methods: The study was conducted on 31 respondents who received filling treatment and 38 respondents who received tooth extraction. All of the respondents carried out to evaluate the total costs incurred in obtaining treatment and QoL between before and after treatment, which consist of the physical aspects, psychological, social, and economic. Results: The average total cost of dental filling treatment of the 31 respondents was Rp. 27,934.45, and in tooth extraction of the 38 respondents at Rp. 22,406.83. The average difference in the QoL, before and after dental filling treatment amounted to 121.25. In extractions, QoL difference in value before and after treatment at 132.36. Cost effectiveness ratio value in dental filling treatment amounted to 230.37, and in tooth extraction at 169.63. Conclusion: It is concluded that cost effectiveness ratio in the filling treatment is higher than the extraction, that the tooth extraction treatment is considered more cost effective than filling treatment.Latar belakang: Pelaksanaan program pelayanan kesehatan gigi di Puskesmas Balongsari selama tiga tahun, yaitu tahun 2006 hingga 2008, memiliki rata-rata rasio perbandingan perawatan tumpatan dengan pencabutan gigi (1:1,79 yang
7 CFR 58.730 - Filling containers.
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Filling containers. 58.730 Section 58.730 Agriculture... Procedures § 58.730 Filling containers. Hot fluid cheese from the cookers may be held in hotwells or hoppers... shall effectively measure the desired amount of product into the pouch or container in a sanitary manner...
Measurements of the branching fractions of [Formula: see text] decays.
Aaij, R; Abellan Beteta, C; Adametz, A; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Del Buono, L; Deplano, C; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dickens, J; Dijkstra, H; Dogaru, M; Domingo Bonal, F; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Harrison, P F; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jansen, F; Jaton, P; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; von Loeben, J; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Mazurov, A; McCarthy, J; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nisar, S; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; Dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schleich, S; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Smith, M; Sobczak, K; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zvyagin, A
The branching fractions of the decay [Formula: see text] for different intermediate states are measured using data, corresponding to an integrated luminosity of 1.0 fb -1 , collected by the LHCb experiment. The total branching fraction, its charmless component [Formula: see text] and the branching fractions via the resonant [Formula: see text] states η c (1 S ) and ψ (2 S ) relative to the decay via a J / ψ intermediate state are [Formula: see text] Upper limits on the B + branching fractions into the η c (2 S ) meson and into the charmonium-like states X (3872) and X (3915) are also obtained.
Modeling and Fault Simulation of Propellant Filling System
International Nuclear Information System (INIS)
Jiang Yunchun; Liu Weidong; Hou Xiaobo
2012-01-01
Propellant filling system is one of the key ground plants in launching site of rocket that use liquid propellant. There is an urgent demand for ensuring and improving its reliability and safety, and there is no doubt that Failure Mode Effect Analysis (FMEA) is a good approach to meet it. Driven by the request to get more fault information for FMEA, and because of the high expense of propellant filling, in this paper, the working process of the propellant filling system in fault condition was studied by simulating based on AMESim. Firstly, based on analyzing its structure and function, the filling system was modular decomposed, and the mathematic models of every module were given, based on which the whole filling system was modeled in AMESim. Secondly, a general method of fault injecting into dynamic system was proposed, and as an example, two typical faults - leakage and blockage - were injected into the model of filling system, based on which one can get two fault models in AMESim. After that, fault simulation was processed and the dynamic characteristics of several key parameters were analyzed under fault conditions. The results show that the model can simulate effectively the two faults, and can be used to provide guidance for the filling system maintain and amelioration.
33 CFR 183.564 - Fuel tank fill system.
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel tank fill system. 183.564...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.564 Fuel tank fill system. (a) Each fuel fill opening must be located so that a gasoline overflow of up to five...
International Nuclear Information System (INIS)
Fradelizi, D.; Mahouy, G.; de Riberolles, C.; Lecompte, Y.; Alhomme, P.; Douard, M.C.; Chotin, G.; Martelli, H.; Daburon, F.; Vaiman, M.
1981-01-01
Experiments with pigs have been performed in order to establish bone marrow chimerism and kidney graft tolerance between SLA genotyped semi-incompatible animals. Recipients were conditioned by means of conventional fractionated total lymphoid irradiation (TLI) delivered by a vertical cobalt source. The principal lymphoid regions of the pig, including thymus and spleen, were submitted to irradiation. Two protocols were tested: A = 250 cGy four times a week x 13 times (TLI) (two animals) and B = 350 cGy three times a week x 8 times (TLI) (four animals). Bone marrow cells were injected 24 h after the last irradiation. One day later, bilateral nephrectomy and the graft of one kidney from the bone marrow cell donor were performed simultaneously. Results convinced us that application of the TLI protocol to humans is not yet practicable and that further experimental work is needed
Better building of valley fills
Energy Technology Data Exchange (ETDEWEB)
Chironis, N.P.
1980-03-01
Current US regulations for building valley fills or head of hollow fills to hold excess spoil resulting from contour mining are meeting with considerable opposition, particularly from operators in steep-slope areas. An alternative method has been submitted to the Office of Surface Mining by Virgina. Known as the zoned concept method, it has already been used successfully in building water-holding dams and coal refuse embankments on sloping terrain. The ways in which drainage and seepage are managed are described.
Radio resource management using geometric water-filling
He, Peter; Zhou, Sheng; Niu, Zhisheng
2014-01-01
This brief introduces the fundamental theory and development of managing radio resources using a water-filling algorithm that can optimize system performance in wireless communication. Geometric Water-Filling (GWF) is a crucial underlying tool in emerging communication systems such as multiple input multiple output systems, cognitive radio systems, and green communication systems. Early chapters introduce emerging wireless technologies and provide a detailed analysis of water-filling. The brief investigates single user and multi-user issues of radio resource management, allocation of resources
One-dimensional Gromov minimal filling problem
International Nuclear Information System (INIS)
Ivanov, Alexandr O; Tuzhilin, Alexey A
2012-01-01
The paper is devoted to a new branch in the theory of one-dimensional variational problems with branching extremals, the investigation of one-dimensional minimal fillings introduced by the authors. On the one hand, this problem is a one-dimensional version of a generalization of Gromov's minimal fillings problem to the case of stratified manifolds. On the other hand, this problem is interesting in itself and also can be considered as a generalization of another classical problem, the Steiner problem on the construction of a shortest network connecting a given set of terminals. Besides the statement of the problem, we discuss several properties of the minimal fillings and state several conjectures. Bibliography: 38 titles.
Series expansion in fractional calculus and fractional differential equations
Li, Ming-Fan; Ren, Ji-Rong; Zhu, Tao
2009-01-01
Fractional calculus is the calculus of differentiation and integration of non-integer orders. In a recently paper (Annals of Physics 323 (2008) 2756-2778), the Fundamental Theorem of Fractional Calculus is highlighted. Based on this theorem, in this paper we introduce fractional series expansion method to fractional calculus. We define a kind of fractional Taylor series of an infinitely fractionally-differentiable function. Further, based on our definition we generalize hypergeometric functio...
Assessment of periapical health, quality of root canal filling, and ...
African Journals Online (AJOL)
Sixty three teeth were found to have short root canal fillings, whereas 74 teeth had adequate root canal fillings, and the remaining 10 teeth had over extended root canal filling. A significant correlation was observed between the length of root filling and apical periodontitis (P = 0,023). Inadequately dense root canal filling was ...
Convergent ablation measurements with gas-filled rugby hohlraum on OMEGA
Casner, A.; Jalinaud, T.; Galmiche, D.
2016-03-01
Convergent ablation experiments with gas-filled rugby hohlraum were performed for the first time on the OMEGA laser facility. A time resolved 1D streaked radiography of capsule implosion is acquired in the direction perpendicular to hohlraum axis, whereas a 2D gated radiography is acquired at the same time along the hohlraum axis on a x-ray framing camera. The implosion trajectory has been measured for various kinds of uniformly doped ablators, including germanium-doped and silicon-doped polymers (CH), at two different doping fraction (2% and 4% at.). Our experiments aimed also at measuring the implosion performance of laminated capsules. A laminated ablator is constituted by thin alternate layers of un-doped and doped CH. It has been previously shown in planar geometry that laminated ablators could mitigate Rayleigh Taylor growth at ablation front. Our results confirm that the implosion of a capsule constituted with a uniform or laminated ablator behaves similarly, in accordance with post-shot simulations performed with the CEA hydrocode FCI2.
Tribological properties of nanosized calcium carbonate filled polyamide 66 nanocomposites
Energy Technology Data Exchange (ETDEWEB)
Itagaki, Kaito [Department of Mechanical Engineering, Graduate School of Engineering, Kogakuin University, 2665-1 Nakano, Hachioji, Tokyo 192-0015 Japan (Japan); Nishitani, Yosuke [Department of Mechanical Engineering, Faculty of Engineering, Kogakuin University, 2665-1 Nakano, Hachioji, Tokyo, 192-0015 Japan (Japan); Kitano, Takeshi [Polymer Centre, Faculty of Technology, Tomas Bata University in Zlin, T.G.M. 275, Zlin, 767 72 Czech Republic (Czech Republic); Eguchi, Kenichiro [Shiraishi Central Laboratories, 4-78 Motohama,Amagasaki,Hyogo,660-0085 Japan (Japan)
2016-03-09
For the purpose of developing high performance tribomaterials for mechanical sliding parts such as gears, bearings and so on, nanosized calcium carbonate (nano-CaCO{sub 3}) filled polyamide 66 (PA66) nanocomposites were investigated. The nano-CaCO{sub 3} was a kind of precipitated (colloid typed) CaCO{sub 3}, and its average particle size was 40, 80 and 150 nm. Surface treatment was performed by fatty acid on the nano-CaCO{sub 3} and its volume fraction in the nanocomposite was varied from 1 to 20vol.%. These nanocomposites were melt-mixed by a twin screw extruder and injection-molded. Tribological properties were measured by two types of sliding wear testers such as ring-on-plate type and ball-on-plate type one under dry condition. The counterface, worn surface and wear debris were observed by digital microscope and scanning electron microscope. It was found that the nano-CaCO{sub 3} has a good effect on the tribological properties, although the effect on the frictional coefficient and specific wear rate is differed by the volume fraction and the type of sliding wear modes. This is attributed to the change of wear mechanisms, which is the change of form of the transfer films on the counterface and the size of wear debris. It follows from these results that PA66/nano-CaCO{sub 3} nanocomposites may be possible to be the high performance tribomaterials.
Space-Time Water-Filling for Composite MIMO Fading Channels
Directory of Open Access Journals (Sweden)
2006-01-01
Full Text Available We analyze the ergodic capacity and channel outage probability for a composite MIMO channel model, which includes both fast fading and shadowing effects. The ergodic capacity and exact channel outage probability with space-time water-filling can be evaluated through numerical integrations, which can be further simplified by using approximated empirical eigenvalue and maximal eigenvalue distribution of MIMO fading channels. We also compare the performance of space-time water-filling with spatial water-filling. For MIMO channels with small shadowing effects, spatial water-filling performs very close to space-time water-filling in terms of ergodic capacity. For MIMO channels with large shadowing effects, however, space-time water-filling achieves significantly higher capacity per antenna than spatial water-filling at low to moderate SNR regimes, but with a much higher channel outage probability. We show that the analytical capacity and outage probability results agree very well with those obtained from Monte Carlo simulations.
Beda, Alessandro; Güldner, Andreas; Carvalho, Alysson R; Zin, Walter Araujo; Carvalho, Nadja C; Huhle, Robert; Giannella-Neto, Antonio; Koch, Thea; de Abreu, Marcelo Gama
2014-01-01
Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.
Directory of Open Access Journals (Sweden)
Alessandro Beda
Full Text Available BACKGROUND: Measuring esophageal pressure (Pes using an air-filled balloon catheter (BC is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC, during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. MAIN RESULTS: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal than in AFC and LFC (<3%. Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. CONCLUSIONS: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.
Particle Simulation of Fractional Diffusion Equations
Allouch, Samer
2017-07-12
This work explores different particle-based approaches to the simulation of one-dimensional fractional subdiffusion equations in unbounded domains. We rely on smooth particle approximations, and consider four methods for estimating the fractional diffusion term. The first method is based on direct differentiation of the particle representation, it follows the Riesz definition of the fractional derivative and results in a non-conservative scheme. The other three methods follow the particle strength exchange (PSE) methodology and are by construction conservative, in the sense that the total particle strength is time invariant. The first PSE algorithm is based on using direct differentiation to estimate the fractional diffusion flux, and exploiting the resulting estimates in an integral representation of the divergence operator. Meanwhile, the second one relies on the regularized Riesz representation of the fractional diffusion term to derive a suitable interaction formula acting directly on the particle representation of the diffusing field. A third PSE construction is considered that exploits the Green\\'s function of the fractional diffusion equation. The performance of all four approaches is assessed for the case of a one-dimensional diffusion equation with constant diffusivity. This enables us to take advantage of known analytical solutions, and consequently conduct a detailed analysis of the performance of the methods. This includes a quantitative study of the various sources of error, namely filtering, quadrature, domain truncation, and time integration, as well as a space and time self-convergence analysis. These analyses are conducted for different values of the order of the fractional derivatives, and computational experiences are used to gain insight that can be used for generalization of the present constructions.
Particle Simulation of Fractional Diffusion Equations
Allouch, Samer; Lucchesi, Marco; Maî tre, O. P. Le; Mustapha, K. A.; Knio, Omar
2017-01-01
This work explores different particle-based approaches to the simulation of one-dimensional fractional subdiffusion equations in unbounded domains. We rely on smooth particle approximations, and consider four methods for estimating the fractional diffusion term. The first method is based on direct differentiation of the particle representation, it follows the Riesz definition of the fractional derivative and results in a non-conservative scheme. The other three methods follow the particle strength exchange (PSE) methodology and are by construction conservative, in the sense that the total particle strength is time invariant. The first PSE algorithm is based on using direct differentiation to estimate the fractional diffusion flux, and exploiting the resulting estimates in an integral representation of the divergence operator. Meanwhile, the second one relies on the regularized Riesz representation of the fractional diffusion term to derive a suitable interaction formula acting directly on the particle representation of the diffusing field. A third PSE construction is considered that exploits the Green's function of the fractional diffusion equation. The performance of all four approaches is assessed for the case of a one-dimensional diffusion equation with constant diffusivity. This enables us to take advantage of known analytical solutions, and consequently conduct a detailed analysis of the performance of the methods. This includes a quantitative study of the various sources of error, namely filtering, quadrature, domain truncation, and time integration, as well as a space and time self-convergence analysis. These analyses are conducted for different values of the order of the fractional derivatives, and computational experiences are used to gain insight that can be used for generalization of the present constructions.
International Nuclear Information System (INIS)
Stephan, C.
1993-01-01
The main types of gas filled nuclear detectors: ionization chambers, proportional counters, parallel-plate avalanche counters (PPAC) and microstrip detectors are described. New devices are shown. A description of the processes involved in such detectors is also given. (K.A.) 123 refs.; 25 figs.; 3 tabs
Feasibility of fractionating Myoview cold kits for cost reduction
International Nuclear Information System (INIS)
Penglis, S.; Tsopelas, C.
1999-01-01
Full text: Myoview is a freeze-dried ethylene diphosphine ligand that upon reconstitution with 99 Tc m -pertechnetate yields a preparation containing the lipophilic cationic myocardial imaging agent 99 Tc m -tetrofosmin (Tf). The aim of this study was to determine the feasibility of fractionating Myoview kits to reduce the cost of the kit, currently A$350 per vial. Myoview vials were reconstituted with N 2 -flushed saline and split into 4 or 5 aliquots of 0.5 ml, then stored at -80 deg C in N 2 -filled vials for up to 3 months. 99 Tc m -Tf was prepared by the addition of varying volumes of 99 Tc m -pertechnetate (1.1 GBq.ml- 1 ) to give a final ligand concentration of 14.4 μg.ml- 1 , followed by a 15 min incubation at room temperature. Radiochemical purity (RCP) was examined at 0, 1, 2 and 3 months post-fractionation. At each time point, RCP was determined at 0,1, 2, 4, 6 and 24 h post-reconstitution. RCP was measured using the thin layer chromatography method according to the manufacturer's instructions. Over the 3 month evaluation period, RCP was maintained at 96.4 ± 1.7% (n = 48) over 24 h at room temperature. Animal biodistribution studies were used to validate the final product from the full cold kit to that from the fractionated kits. In conclusion, these results show that Myoview kits can be successfully fractionated and stored for up to 3 months. The subsequent 99 Tc m -Tf can be used to provide significant cost reductions, especially when only 1 patient dose is required
M.T. Tyree; H. Cochard; P. Cruziat
2003-01-01
When petioles of transpiring leaves are cut in the air, according to the 'Scholander assumption', the vessels cut open should fill with air as the water is drained away by continued transpiration, The distribution of air-filled vessels versus distance from the cut surface should match the distribution of lengths of 'open vessels', i.e. vessels cut...
Reirradiation of brain and skull base tumors with fractionated stereotactic radiotherapy
International Nuclear Information System (INIS)
Tokuuye, Koichi; Akine, Yasuyuki; Sumi, Minako; Kagami, Yoshikazu; Ikeda, Hiroshi; Oyama, Hiroshi; Inou, Yasushi; Shibui, Soichiro; Nomura, Kazuhiro
1998-01-01
Purpose: We evaluated the feasibility of fractionated stereotactic radiotherapy for small intracranial recurrences after conventional radiotherapy. Methods and Materials: Nineteen patients who had initially undergone conventional radiotherapy to intracranial lesions, receiving a median total dose of 50 Gy in 5 weeks, were retreated with stereotactic radiotherapy for their recurrences and received a median total dose of 42 Gy in seven fractions over 2.3 weeks. Results: Of the 19 patients, 15 achieved local control 3-51 months after reirradiation. No patient suffered from acute reaction, but one patient with a history of extensive radiotherapy developed progressive radionecrosis 9 months after reirradiation. Conclusions: Fractionated stereotactic radiotherapy of intracranial recurrences appears to be effective in achieving in local control with negligible morbidity. We believe it merits further investigation in a prospective study
Directory of Open Access Journals (Sweden)
M. L. Kavvas
2017-10-01
Full Text Available Using fractional calculus, a dimensionally consistent governing equation of transient, saturated groundwater flow in fractional time in a multi-fractional confined aquifer is developed. First, a dimensionally consistent continuity equation for transient saturated groundwater flow in fractional time and in a multi-fractional, multidimensional confined aquifer is developed. For the equation of water flux within a multi-fractional multidimensional confined aquifer, a dimensionally consistent equation is also developed. The governing equation of transient saturated groundwater flow in a multi-fractional, multidimensional confined aquifer in fractional time is then obtained by combining the fractional continuity and water flux equations. To illustrate the capability of the proposed governing equation of groundwater flow in a confined aquifer, a numerical application of the fractional governing equation to a confined aquifer groundwater flow problem was also performed.
Geomechanical investigations for the designing of cemented filling
Energy Technology Data Exchange (ETDEWEB)
Berry, P.
1980-05-15
Laboratory and in situ investigations have led to the identification of the main geomechanical parameters that condition the stability of the cemented fill in the Gavorrano pyrite mine (Tuscany, Italy); such parameters were used for working out a satisfactory mining method. The pyrite is mined with the descending horizontal slice method with integral cemented filling which is obtained by throwing a mixture of limestone aggregates and cement into the mined voids. The laboratory geomechanical investigations carried out on fill samples have pointed out that the physical and mechanical characteristics are highly variable and this is essentially due to the fact that the fill is cast into place by compressed air. In particular, it was pointed out that the strength depends upon the cement content and upon the porosity according to a power law. The in situ measurements of the convergence between the roof and the floor, and the load measurements pointed out the considerable importance of the horizontal and vertical joints that cross the fill mass and that are inevitably brought about by a discontinuity of the fill. The results of the study made it possible to adopt an acceptable geomechanical behaviour model of the fill. On the basis of this model the mining pattern was deeply modified, the width and the height of the slices were considerably enlarged and thus the output was improved.
Oxygenation of spontaneous canine tumors during fractionated radiation therapy
International Nuclear Information System (INIS)
Achermann, R.E.; Ohlerth, S.M.; Bley, C.R.; Inteeworn, N.; Schaerz, M.; Wergin, M.C.; Kaser-Hotz, B.; Gassmann, M.; Roos, M.
2004-01-01
Background and purpose: tumor oxygenation predicts treatment outcome, and reoxygenation is considered important in the efficacy of fractionated radiation therapy. Therefore, the purpose of this study was to document the changes of the oxygenation status in spontaneous canine tumors during fractionated radiation therapy using polarographic needle electrodes. Material and methods: tumor oxygen partial pressure (pO 2 ) measurements were performed with the eppendorf-pO 2 -Histograph. The measurements were done under general anesthesia, and probe tracks were guided with ultrasound. pO 2 was measured before radiation therapy in all dogs. In patients treated with curative intent, measurements were done sequentially up to eight times (total dose: 45-59.5 Gy). Oxygenation status of the palliative patient group was examined before each fraction of radiation therapy up to five times (total dose: 24-30 Gy). Results: 15/26 tumors had a pretreatment median pO 2 ≤ 10 mmHg. The pO 2 values appeared to be quite variable in individual tumors during fractionated radiation therapy. The pO 2 of initially hypoxic tumors (pretreatment median pO 2 ≤ 10 mmHg) remained unchanged during fractionated radiotherapy, whereas in initially normoxic tumors the pO 2 decreased. Conclusion: hypoxia is common in spontaneous canine tumors, as 57.7% of the recorded values were ≥ 10 mmHg. The data of this study showed that initially hypoxic tumors remained hypoxic, whereas normoxic tumors became more hypoxic. (orig.)
International Nuclear Information System (INIS)
Mori, T.; Nemoto, M.; Hoshino, E.; Shimokura, F.; Murakami, E.; Takahashi, S.; Nakazawa, Masanori
2013-01-01
Bladder filling with reproducible volume is important for the radiotherapy in the title (IMRT) with less adverse events. The optimal bladder filling volume, 150 mL, has been reported recently for IMRT, with which as a standard, the pretreatment was retrospectively examined aiming at less patient's pain in this study. Subjects were 10 typical patients among total 98 in total 1,476 irradiations of IMRT during the period Feb. 2008-June 2011, who had been needed for controlling the volume of drinking water and time of bladder filling. Five cases difficult to conduct IMRT with their initial protocol alone were selected from the 10 patients, on whom following 3 items were examined. Here, in authors' hospital, IMRT (46-50 Gy) had been conducted as a booster therapy following the usual irradiation (20-24 Gy). First, the relationship was examined between bladder filling and pretreatment by the ratio, CBCT (cone-beam CT)-volume/plan-volume as an attainment, where the bladder volume was measured just before every therapy with CBCT image together with pretreatment for the drinking water volume and waiting time. Second, measured were volumes of the bladder filling just before the therapy and urinated after. Third, status of urination was heard. The protocol was then improved on results and remaining 5 patients underwent the pretreatment with the improved protocol. It was found that pretreatment for the control of the volume of drinking water and subsequent bladder filling was necessary not only after patient's hospital visit but also before, based on their living cycles. Nursing care chart made here by authors based on the finding above was thought important for IMRT with reproducible bladder filling and less adverse events. (T.T.)
SOIL ORGANIC MATTER FRACTIONS IN PRESERVED AND DISTURBED WETLANDS OF THE CERRADO BIOME
Directory of Open Access Journals (Sweden)
Ricardo Fernandes de Sousa
2015-02-01
Full Text Available Veredas are humid tropical ecosystems, generally associated to hydromorphic soils and a shallow water table. The soils of these ecosystems are affected by the use of the areas around these veredas. The objective of this study was to determine soil organic matter (SOM fractions in veredas adjacent to preserved (native savanna and disturbed environments (agricultural areas and pastures in the Cerrado biome. Soil samples were collected from the 0-10 and 10-20 cm layers along reference lines drawn along the relief following the upper, middle and lower positions of one of the slopes, in the direction of the draining line of the vereda. The soil analysis determined: total soil OC, total nitrogen and C:N ratio; C and N contents and C:N ratio in particulate and mineral-associated fractions (of SOM; fulvic acids, humic acids and humin fractions and ratio between humic and fulvic acids. The agricultural use around the veredas induced changes in the SOM fractions, more pronounced in the lower part of the slope. In the soil surface of this part, the OC levels in the humic substances and the particulate fraction of SOM, as well as total soil OC were reduced in the vereda next to crop fields.
THE SERUM PROTEIN FRACTIONS IN THYMOQUINONE TREATED RATS.
A, Güllü; S, Dede
2016-01-01
TQ has been used as treatment and preventive agent for many diseases over the years. The goal of this study was to investigate the effects of TQ supplement on fractions of serum proteins. Fourteen male Wistar-Albino rats (200-250 g weight) were used as material for two groups; (control (C) and thymoquinone (TQ) respectively. Each group contained seven rats. The control group had only corn oil, while the TQ group was dissolved in corn oil. 30 mg/kg/day were given by oral gavage for four weeks. The serum protein fractions were identified using cellulose acetate technique. The total protein level and albumin, α-1, α-2 fractions and A/G ratio have showed no difference between groups (p>0.05). β-globulin fractions of TQ group were higher than control's (pfractions may have originated from elevation or decline synthesis, or activities of containing proteins.
Mechanical behavior of cellular borosilicate glass with pressurized Ar-filled closed pores
International Nuclear Information System (INIS)
Wang Bo; Matsumaru, Koji; Yang Jianfeng; Fu Zhengyi; Ishizaki, Kozo
2012-01-01
High strength borosilicate foams were fabricated by melting glass powder under high-pressure argon gas and subsequent heat treatment of the glass bulk at atmospheric pressure. In the first step, borosilicate glass powder was melted at 1100 °C for 1 h by capsule-free hot isostatic pressing (HIPing) under a high gas pressure of 10–70 MPa. Pressurized Ar-filled spherical pores were introduced into the glass, and argon atoms were dissolved in the glass network structure. The expansion of argon-filled pores and the release of the dissolved Ar gas resulted in the formation of pressurized Ar-filled closed pores by isothermal heat treatment at 800 °C for 10 min. A high porosity of up to 80% with a bimodal distribution of micro-size cells was obtained for the resultant cellular borosilicate glass. By increasing the total gas pressure from 10 to 70 MPa, the compressive strength and the Young’s modulus were increased considerably from 15 to 52 MPa and from 4.1 to 12.6 GPa, respectively, which can be substantially attributed to the high collapse stress from the high enclosed gas pressure. The cellular glass with a high porosity showed a large failure strain under uniaxial compression.
Energy Technology Data Exchange (ETDEWEB)
Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)
2017-11-15
To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer
Taha, N A; Maghaireh, G A; Ghannam, A S; Palamara, J E
2017-08-01
To evaluate the effect of using a bulk-fill flowable base material on fracture strength and fracture patterns of root-filled maxillary premolars with MOD preparations restored with laminate restorations. Fifty extracted maxillary premolars were selected for the study. Standardized MOD cavities with endodontic treatment were prepared for all teeth, except for intact control. The teeth were divided randomly into five groups (n=10); (Group 1) sound teeth, (Group 2) unrestored teeth; (Group 3) MOD cavities with Vitrebond base and resin-based composite (Ceram. X One Universal); (Group 4) MOD cavities with 2mm GIC base (Fuji IX GP) and resin-based composite (Ceram. X One Universal) open laminate, (Group 5) MOD cavities were restored with 4mm of bulk-fill flowable base material (SDR) and resin-based composite (Ceram. X One Universal). All teeth were thermocycled and subjected to a 45° ramped oblique load in a universal testing machine. Fracture load and fracture patterns were recorded. Data were analyzed using one-way ANOVA and Dunnett's T3 test. Restoration in general increased the fracture strength compared to unrestored teeth. The fracture strength of group 5 (bulk-fill) was significantly higher than the fracture strength of the GIC laminate groups and not significantly different from the intact teeth (355±112N, P=0.118). The type of failure was unfavorable for most of the groups, with the majority being mixed failures. The use of a bulk-fill flowable base material significantly increased the fracture strength of extracted root-filled teeth with MOD cavities; however it did not improve fracture patterns to more favorable ones. Investigating restorative techniques that may improve the longevity of root-filled premolar teeth restored with direct resin restorations. Copyright © 2017 Elsevier Ltd. All rights reserved.
M. L. Kavvas; T. Tu; A. Ercan; J. Polsinelli
2017-01-01
Using fractional calculus, a dimensionally consistent governing equation of transient, saturated groundwater flow in fractional time in a multi-fractional confined aquifer is developed. First, a dimensionally consistent continuity equation for transient saturated groundwater flow in fractional time and in a multi-fractional, multidimensional confined aquifer is developed. For the equation of water flux within a multi-fractional multidimensional confined aquifer, a dimensionally...
Optimization of foam-filled bitubal structures for crashworthiness criteria
International Nuclear Information System (INIS)
Zhang, Yong; Sun, Guangyong; Li, Guangyao; Luo, Zhen; Li, Qing
2012-01-01
Highlights: ► The paper aims to optimize foam-filled bitubal squared column for crashworthiness. ► It explores different formulations and configurations of design. ► The optimal foam-filled bitubal column is better than foam-filled monotubal column. ► The optimal foam-filled bitubal column is better than empty bitubal column. -- Abstract: Thin-walled structures have been widely used as key components in automobile and aerospace industry to improve the crashworthiness and safety of vehicles while maintaining overall light-weight. This paper aims to explore the design issue of thin-walled bitubal column structures filled with aluminum foam. As a relatively new filler material, aluminum foam can increase crashworthiness without sacrificing too much weight. To optimize crashworthiness of the foam-filled bitubal square column, the Kriging meta-modeling technique is adopted herein to formulate the objective and constraint functions. The genetic algorithm (GA) and Non-dominated Sorting Genetic Algorithm II (NSGA II) are used to seek the optimal solutions to the single and multiobjective optimization problems, respectively. To compare with other thin-walled configurations, the design optimization is also conducted for empty bitubal column and foam-filled monotubal column. The results demonstrate that the foam-filled bitubal configuration has more room to enhance the crashworthiness and can be an efficient energy absorber.
Development of gap filling technique in HLW repository
International Nuclear Information System (INIS)
Nakashima, Hitoshi; Saito, Akira; Ishii, Takashi; Toguri, Satohito; Okihara, Mitsunobu; Iwasa, Kengo
2016-01-01
HLW is supposed to be disposed underground at depths more than 300 m in Japan. Buffer is an artificial barrier that controls radionuclides migrating into the groundwater. The buffer would be made of a natural swelling clay, bentonite. Construction technology for the buffer has been studied for many years, but studies for the gaps surrounding the buffer are little. The proper handling of the gaps is important for guaranteeing the functions of the buffer. In this paper, gap filling techniques using bentonite pellets have been developed in order to the gap having the same performance as the buffer. A new method for manufacturing high-density spherical pellets has been developed to fill the gap higher density ever reported. For the bentonite pellets, the filling performance and how to use were determined. And full-scale filling tests provided availability of the bentonite pellets and filling techniques. (author)
Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes
Fidiani, Elok; Da Costa, Pedro M. F. J.; Wolter, Anja U. B.; Maier, Diana; Buechner, Bernd; Hampel, Silke
2013-01-01
Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.
Magnetically Active and Coated Gadolinium-Filled Carbon Nanotubes
Fidiani, Elok
2013-08-15
Gd-filled carbon nanotubes (which include the so-called gadonanotubes(1)) have been attracting much interest due to their potential use in medical diagnostic applications. In the present work, a vacuum filling method was performed to confine gadolinium(III) iodide in carbon nanotubes (CNTs). Filling yields in excess of 50% were obtained. Cleaning and dosing of the external walls was undertaken, as well as the study of the filled CNT magnetic properties. Overall, we found that the encapsulating procedure can lead to reduction of the lanthanide metal and induce disorder in the initial GdI3-type structure. Notwithstanding, the magnetic response of the material is not compromised, retaining a strong paramagnetic response and an effective magnetic moment of similar to 6 mu B. Our results may entice further investigation into whether an analogous Gd3+ to Gd2+ reduction takes place in other Gd-filled CNT systems.
DEFF Research Database (Denmark)
Celik, Tim Holst
on the statesituated tension-filled functional relationship between legitimation and accumulation, the study both historically and theoretically reworks this approach and reapplies it for the post-1970s/1990s governance period. It asks whether and to what extent governance has served as a distinctive post- 1970s/1990s...
Estimation of Total Error in DWPF Reported Radionuclide Inventories
International Nuclear Information System (INIS)
Edwards, T.B.
1995-01-01
This report investigates the impact of random errors due to measurement and sampling on the reported concentrations of radionuclides in DWPF's filled canister inventory resulting from each macro-batch. The objective of this investigation is to estimate the variance of the total error in reporting these radionuclide concentrations
Modelling size-fractionated primary production in the Atlantic Ocean from remote sensing
Brewin, Robert J. W.; Tilstone, Gavin H.; Jackson, Thomas; Cain, Terry; Miller, Peter I.; Lange, Priscila K.; Misra, Ankita; Airs, Ruth L.
2017-11-01
Marine primary production influences the transfer of carbon dioxide between the ocean and atmosphere, and the availability of energy for the pelagic food web. Both the rate and the fate of organic carbon from primary production are dependent on phytoplankton size. A key aim of the Atlantic Meridional Transect (AMT) programme has been to quantify biological carbon cycling in the Atlantic Ocean and measurements of total primary production have been routinely made on AMT cruises, as well as additional measurements of size-fractionated primary production on some cruises. Measurements of total primary production collected on the AMT have been used to evaluate remote-sensing techniques capable of producing basin-scale estimates of primary production. Though models exist to estimate size-fractionated primary production from satellite data, these have not been well validated in the Atlantic Ocean, and have been parameterised using measurements of phytoplankton pigments rather than direct measurements of phytoplankton size structure. Here, we re-tune a remote-sensing primary production model to estimate production in three size fractions of phytoplankton (10 μm) in the Atlantic Ocean, using measurements of size-fractionated chlorophyll and size-fractionated photosynthesis-irradiance experiments conducted on AMT 22 and 23 using sequential filtration-based methods. The performance of the remote-sensing technique was evaluated using: (i) independent estimates of size-fractionated primary production collected on a number of AMT cruises using 14C on-deck incubation experiments and (ii) Monte Carlo simulations. Considering uncertainty in the satellite inputs and model parameters, we estimate an average model error of between 0.27 and 0.63 for log10-transformed size-fractionated production, with lower errors for the small size class (10 μm), and errors generally higher in oligotrophic waters. Application to satellite data in 2007 suggests the contribution of cells 2 μm to total
Partially filled Landau level at even denominators: A vortex metal with a Berry phase
You, Yizhi
2018-04-01
We develop a vortex metal theory for a partially filled Landau level at ν =1/2 n whose ground state contains a composite Fermi surface formed by the vortex of electrons. In the projected Landau-level limit, the composite Fermi surface contains a -π/n Berry phase. Such a fractional Berry phase is a consequence of Landau-level projection which produces the Girvin-MacDonald-Platzman [S. M. Girvin, A. H. MacDonald, and P. M. Platzman, Phys. Rev. B 33, 2481 (1986), 10.1103/PhysRevB.33.2481] guiding center algebra and embellishes an anomalous velocity to the equation of motion for the vortex metal. Further, we investigate a particle-hole symmetric bilayer system with ν1=1/2 n and ν2=1 -1/2 n at each layer, and demonstrate that the -π/n Berry phase on the composite Fermi surface leads to the suppression of 2 kf backscattering between the particle-hole partner bilayer, which could be a smoking gun to detect the fractional Berry phase. We also mention various instabilities and competing orders in such bilayer systems, including a Z4 n topological order phase driven by quantum criticality.
Binding of inorganic mercury by subcellular fractions and proteins of rat kidneys
Energy Technology Data Exchange (ETDEWEB)
Komsta-Szumska, E; Chmielnicka, J; Piotrowski, J K
1976-01-01
Inorganic mercury, administered to rats in a single dose of 0.5 mg Hg/kg is accumulated in the kidneys mainly in the soluble (54 percent) and nuclear (30 percent) fractions, showing decreasing tendency with time. Mitochondrial and microsomal fractions, initially accumulating approximately 11 and 6 percent of total Hg, show a tendency to increase the absolute level of Hg for the first week after administration. In the soluble fraction low-molecular weight, metallothioneinlike proteins are mainly responsible for the accumulation of mercury; in other fractions proteins of higher molecular weight prevail.
International Nuclear Information System (INIS)
Olsen, D.R.
1995-01-01
The total effect (TE) has been calculated for two different fractionation formalisms: the consecutive and repetitive fractionation mechanism, using a modified linear quadratic (LQ) model which includes the effect of apoptosis. For a given total dose, an increase in TE is seen when increasing the dose per fraction as well as the apoptotic fraction (F a ). Also, the TE increases with increasing α/β ratio (of the modified LQ model). The ratio of TE for tumour tissue and TE for late reacting tissue is calculated assuming the absence of apoptosis in late reacting tissue and a common value of α/β (of the modified LQ model). The biological effect ratio (BR) is higher for a large F a and low doses per fraction, than for large doses per fraction and a small F a . Assuming a consecutive fractionation mechanism, the TE formalism is unable to predict a log cell kill of more than 3 for β values of 0.010-0.028. It is less dependent on dose per fraction and F a than the repetitive fractionation mechanism. The biological effect ratio is only slightly higher than 1, and is less influenced by F a , dose per fraction and α/β ratio. A repetitive fractionation mechanism is also consistent with the preliminary results of published fractionation experiments. The calculations indicate that designing fractionation regimes for optimization of biological effect is a process where the role of apoptotic cell inactivation must be maximized, and where the influence of mitotic cell inactivation may be of less importance. (author)
Radiation therapy for hypopharyngeal carcinoma. Impact of fractionation on treatment outcome
International Nuclear Information System (INIS)
Niibe, Yuzuru; Karasawa, Katsuyuki; Igaki, Hiroshi; Miyashita, Hisao; Tanaka, Yoshiaki
2003-01-01
The purpose of the current study was to evaluate the impact of fractionation on the treatment outcome of radiation therapy for hypopharyngeal carcinoma. Thirty-six inoperable or operation-refused hypopharyngeal patients were treated with curative-intended radiation therapy between 1976 and May 2001. Seventeen patients were treated with conventional radiation therapy, 1.8-2.0 Gy per fraction, totaling 64.0 Gy (conventional fractionation (CF) group), and 19 were treated with hyperfractionated radiation therapy, 1.2 Gy per fraction, totaling 74.4 Gy (hyperfractionation (HF) group). The radiation response of the two groups at the end of radiation therapy was almost the same. However, the 2-year local control rates of the HF and CF groups were 59.0% and 26.1% (p=0.012), respectively, a statistically significant differences. Moreover, multivariate analysis showed that HF was an independent prognostic factor for local control. Hyperfractionated radiation therapy was superior to conventional radiation therapy for local control. Local control of hypopharyngeal carcinoma correlated with laryngeal preservation, suggesting that hyperfractionated radiation therapy for hypopharyngeal carcinoma could be beneficial for patient quality of life (QOL). (author)
Indian Academy of Sciences (India)
Boron trifluoride (BF3) proportional counters are used as detectors for thermal neutrons. They are characterized by high neutron sensitivity and good gamma discriminating properties. Most practical BF3 counters are filled with pure boron trifluoride gas enriched up to 96% 10B. But BF3 is not an ideal proportional counter ...
Real-space imaging of fractional quantum Hall liquids
Hayakawa, Junichiro; Muraki, Koji; Yusa, Go
2013-01-01
Electrons in semiconductors usually behave like a gas--as independent particles. However, when confined to two dimensions under a perpendicular magnetic field at low temperatures, they condense into an incompressible quantum liquid. This phenomenon, known as the fractional quantum Hall (FQH) effect, is a quantum-mechanical manifestation of the macroscopic behaviour of correlated electrons that arises when the Landau-level filling factor is a rational fraction. However, the diverse microscopic interactions responsible for its emergence have been hidden by its universality and macroscopic nature. Here, we report real-space imaging of FQH liquids, achieved with polarization-sensitive scanning optical microscopy using trions (charged excitons) as a local probe for electron spin polarization. When the FQH ground state is spin-polarized, the triplet/singlet intensity map exhibits a spatial pattern that mirrors the intrinsic disorder potential, which is interpreted as a mapping of compressible and incompressible electron liquids. In contrast, when FQH ground states with different spin polarization coexist, domain structures with spontaneous quasi-long-range order emerge, which can be reproduced remarkably well from the disorder patterns using a two-dimensional random-field Ising model. Our results constitute the first reported real-space observation of quantum liquids in a class of broken symmetry state known as the quantum Hall ferromagnet.
Development of a method to determine the total C-14 content in saturated salt solutions
International Nuclear Information System (INIS)
Lucks, C.; Prautsch, C.
2016-01-01
This two-step method described here for the determination of the total carbon-14 content in saturated salt solutions is divided in the analysis of the carbon-14 in the evaporable and the non-evaporable fraction. After driving off the inorganic carbon by acidification, the volatile carbon compounds and volatile decomposition products follow with rising temperature inside the sample vessel in a mild stream of oxygen to a tube furnace equipped with CuO catalyst for oxidizing the carbon compounds to CO 2 at a temperature of 800 C. Water is condensed out with an intensive condenser and the released CO 2 is absorbed in a wash bottle filled with sodium hydroxide. Similarly, an aliquot of the evaporation residue is put in the first zone of the tube furnace during the second step of the analysis. After heating the catalyst in the second zone of the furnace to 800 C the residue is heated stepwise to 800 C. By proceeding in this way, the non-volatile compounds are decomposed or oxidised in the oxygen stream and finally completely oxidized by the aid of the catalyst. The released CO 2 is again absorbed in another wash bottle. The carbonate of each fraction is then precipitated as BaCO 3 separately. Finally, the precipitate is washed, dried, finely grounded and covered with toluene scintillation cocktail for measurement in a LSC. The detection limit is about 0,2 Bq/l for a sample volume of 250 ml.
Topological materials discovery using electron filling constraints
Chen, Ru; Po, Hoi Chun; Neaton, Jeffrey B.; Vishwanath, Ashvin
2018-01-01
Nodal semimetals are classes of topological materials that have nodal-point or nodal-line Fermi surfaces, which give them novel transport and topological properties. Despite being highly sought after, there are currently very few experimental realizations, and identifying new materials candidates has mainly relied on exhaustive database searches. Here we show how recent studies on the interplay between electron filling and nonsymmorphic space-group symmetries can guide the search for filling-enforced nodal semimetals. We recast the previously derived constraints on the allowed band-insulator fillings in any space group into a new form, which enables effective screening of materials candidates based solely on their space group, electron count in the formula unit, and multiplicity of the formula unit. This criterion greatly reduces the computation load for discovering topological materials in a database of previously synthesized compounds. As a demonstration, we focus on a few selected nonsymmorphic space groups which are predicted to host filling-enforced Dirac semimetals. Of the more than 30,000 entires listed, our filling criterion alone eliminates 96% of the entries before they are passed on for further analysis. We discover a handful of candidates from this guided search; among them, the monoclinic crystal Ca2Pt2Ga is particularly promising.
Directory of Open Access Journals (Sweden)
Uzay Koc-Vural
2017-05-01
Full Text Available Objectives This study aimed to evaluate the color stability of bulk-fill and nanohybrid resin-based composites polished with 3 different, multistep, aluminum-oxide impregnated finishing and polishing disks. Materials and Methods Disk-shaped specimens (8 mm in diameter and 4 mm in thickness were light-cured between two glass slabs using one nanohybid bulk-fill (Tetric EvoCeram, Ivoclar Vivadent, one micro-hybrid bulk-fill (Quixfil, Dentsply, and two nanohybrid incremental-fill (Filtek Ultimate, 3M ESPE; Herculite XRV Ultra, Kerr resin-based composites, and aged by thermocycling (between 5 - 55℃, 3,000 cycles. Then, they were divided into subgroups according to the polishing procedure as SwissFlex (Coltène/Whaledent, Optidisc (Kerr, and Praxis TDV (TDV Dental (n = 12 per subgroup. One surface of each specimen was left unpolished. All specimens were immersed in coffee solution at 37℃. The color differences (ΔE were measured after 1 and 7 days of storage using a colorimeter based on CIE Lab system. The data were analyzed by univariate ANOVA, Mann-Whitney U test, and Friedmann tests (α = 0.05. Results Univariate ANOVA detected significant interactions between polishing procedure and composite resin and polishing procedure and storage time (p 0.05. Polishing reduced the discoloration resistance of Tetric EvoCeram/SwissFlex, Tetric EvoCeram/Praxis TDV, Quixfil-SwissFlex, and all Herculite XRV Ultra groups after 7 days storage (p < 0.05. Conclusions Discoloration resistance of bulk-fill resin-based composites can be significantly affected by the polishing procedures.
Banks, Bruce A.; Simmons, Julie C.; de Groh, Kim K.; Miller, Sharon K.
2012-01-01
Low atomic oxygen fluence (below 1x10(exp 20) atoms/sq cm) exposure of polymers and paints that have a small ash content and/or inorganic pigment fill does not cause a significant difference in erosion yield compared to unfilled (neat) polymers or paints. However, if the ash and/or inorganic pigment content is increased, the surface population of the inorganic content will begin to occupy a significant fraction of the surface area as the atomic oxygen exposure increases because the ash is not volatile and remains as a loosely attached surface layer. This results in a reduction of the flux of atomic oxygen reacting with the polymer and a reduction in the rate of erosion of the polymer remaining. This paper presents the results of ground laboratory and low Earth orbital (LEO) investigations to evaluate the fluence dependence of atomic oxygen erosion yields of polymers and paints having inorganic fill content.
Creep deformation of restorative resin-composites intended for bulk-fill placement.
El-Safty, S; Silikas, N; Watts, D C
2012-08-01
To determine the creep deformation of several "bulk-fill" resin-composite formulations in comparison with some other types. Six resin-composites; four bulk-fill and two conventional were investigated. Stainless steel split molds (4 mm × 6 mm) were used to prepare cylindrical specimens for creep testing. Specimens were thoroughly irradiated with 650 mW cm(-2). A total of 10 specimens for each material were divided into two groups (n = 5) according to the storage condition; Group A stored dry at 37 °C for 24h and Group B stored in distilled water at 37 °C in an incubator for 24h. Each specimen was loaded (20 MPa) for 2h and unloaded for 2h. The strain deformation was recorded continuously for 4h. Statistical analysis was performed using a two-way ANOVA followed by one-way ANOVA and the Bonferroni post hoc test at a significance level of a = 0.05. The maximum creep strain % ranged from 0.72% up to 1.55% for Group A and the range for Group B increased from 0.79% up to 1.80% due to water sorption. Also, the permanent set ranged from 0.14% up to 0.47% for Group A and from 0.20% up to 0.59% for Group B. Dependent on the material and storage condition, the percentage of creep strain recovery ranged between 64% and 81%. Increased filler loading in the bulk-fill materials decreased the creep strain magnitude. Creep deformation of all studied resin-composites increased with wet storage. The "bulk-fill" composites exhibited an acceptable creep deformation and within the range exhibited by other resin-composites. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
DEFF Research Database (Denmark)
Chowdhury, Md Albarune; de Neergaard, Andreas; Jensen, Lars Stoumann
2014-01-01
Solid-liquid separation of animal slurry, with solid fractions used for composting, has gained interest recently. However, efficient composting of separated animal slurry solid fractions (SSFs) requires a better understanding of the process dynamics in terms of important physical parameters...... and their interacting physical relationships in the composting matrix. Here we monitored moisture content, bulk density, particle density and air-filled porosity (AFP) during composting of SSF collected from four commercially available solid-liquid separators. Composting was performed in laboratory-scale reactors...... for 30 days (d) under forced aeration and measurements were conducted on the solid samples at the beginning of composting and at 10-d intervals during composting. The results suggest that differences in initial physical properties of SSF influence the development of compost maximum temperatures (40...
Directory of Open Access Journals (Sweden)
Annibaldi A.
2013-04-01
Full Text Available A chemical fractionation methodology for determination of the (water soluble and the insoluble (dilute-HCl-extractable fractions of Cd, Pb and Cu in Antarctic snow was set-up and verified for the additivity of the two fractions detected. Molten samples were filtrated and the water-insoluble fraction was extracted by dilute ultrapure HCl (pH ~1.5. Metal determinations were carried out in the two fractions by square wave anodic stripping voltammetry. The total metal concentrations in samples collected in the 2000–2001 austral summer in a clean area (Faraglione Camp in the neighbourhood of the Mario Zucchelli Italian Station were of the order of Cd 10-20 pg g−1, Pb 20–40 pg g−1, Cu 60–120 pg g−1 with an approximate equidistribution between soluble and insoluble fractions. These fractionations compare well (and show a quite consistent temporal trend with those observed in the aerosol samples collected in the same area/period and confirm the close relationship between metal distributions in snow/ice and in the aerosol. At the station metal concentrations increase due to anthropic contribution and the distribution changes with Cd predominantly present in the soluble fraction (~80%, while Pb and Cu are more concentrated in the insoluble fraction, 70–80% and ~70%, respectively.
International Nuclear Information System (INIS)
Ding, C; Hrycushko, B; Jiang, S; Meyer, J; Timmerman, R
2014-01-01
Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm 3 ) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment
Chadda, Harshita; Naveen, Sangeetha Vasudevaraj; Mohan, Saktiswaren; Satapathy, Bhabani K; Ray, Alok R; Kamarul, Tunku
2016-07-01
Although the physical and mechanical properties of hydroxyapatite-filled dental restorative composite resins have been examined, the biocompatibility of these materials has not been studied in detail. The purpose of this in vitro study was to analyze the toxicity of acrylate-based restorative composite resins filled with hydroxyapatite and a silica/hydroxyapatite combination. Five different restorative materials based on bisphenol A-glycidyl methacrylate (bis-GMA) and tri-ethylene glycol dimethacrylate (TEGDMA) were developed: unfilled (H0), hydroxyapatite-filled (H30, H50), and silica/hydroxyapatite-filled (SH30, SH50) composite resins. These were tested for in vitro cytotoxicity by using human bone marrow mesenchymal stromal cells. Surface morphology, elemental composition, and functional groups were determined by scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), and Fourier-transformed infrared spectroscopy (FTIR). The spectra normalization, baseline corrections, and peak integration were carried out by OPUS v4.0 software. Both in vitro cytotoxicity results and SEM analysis indicated that the composite resins developed were nontoxic and supported cell adherence. Elemental analysis with EDX revealed the presence of carbon, oxygen, calcium, silicon, and gold, while the presence of methacrylate, hydroxyl, and methylene functional groups was confirmed through FTIR analysis. The characterization and compatibility studies showed that these hydroxyapatite-filled and silica/hydroxyapatite-filled bis-GMA/TEGDMA-based restorative composite resins are nontoxic to human bone marrow mesenchymal stromal cells and show a favorable biologic response, making them potential biomaterials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
A multifractal approach to space-filling recovery for PET quantification
Energy Technology Data Exchange (ETDEWEB)
Willaime, Julien M. Y., E-mail: julien.willaime@siemens.com; Aboagye, Eric O. [Comprehensive Cancer Imaging Centre, Imperial College London, Hammersmith Hospital, London W12 0NN (United Kingdom); Tsoumpas, Charalampos [Division of Medical Physics, University of Leeds, LS2 9JT (United Kingdom); Turkheimer, Federico E. [Department of Neuroimaging, Institute of Psychiatry, King’s College London, London SE5 8AF (United Kingdom)
2014-11-01
Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.
Fractional variational calculus in terms of Riesz fractional derivatives
International Nuclear Information System (INIS)
Agrawal, O P
2007-01-01
This paper presents extensions of traditional calculus of variations for systems containing Riesz fractional derivatives (RFDs). Specifically, we present generalized Euler-Lagrange equations and the transversality conditions for fractional variational problems (FVPs) defined in terms of RFDs. We consider two problems, a simple FVP and an FVP of Lagrange. Results of the first problem are extended to problems containing multiple fractional derivatives, functions and parameters, and to unspecified boundary conditions. For the second problem, we present Lagrange-type multiplier rules. For both problems, we develop the Euler-Lagrange-type necessary conditions which must be satisfied for the given functional to be extremum. Problems are considered to demonstrate applications of the formulations. Explicitly, we introduce fractional momenta, fractional Hamiltonian, fractional Hamilton equations of motion, fractional field theory and fractional optimal control. The formulations presented and the resulting equations are similar to the formulations for FVPs given in Agrawal (2002 J. Math. Anal. Appl. 272 368, 2006 J. Phys. A: Math. Gen. 39 10375) and to those that appear in the field of classical calculus of variations. These formulations are simple and can be extended to other problems in the field of fractional calculus of variations
International Nuclear Information System (INIS)
Nakagawa, Hiroaki
1986-01-01
Using ECG-gated cardiac blood pool scintigraphy (BPS), left ventricular (LV) diastolic function was evaluated in various heart disease, especially in ischemic heart disease (IHD). LV function indices (2 systolic and 9 diastolic) were obtained from LV time activity curve derived from BPS. Among various diastolic indices, peak filling rate (PFR) and 2 other indices were significantly influenced by heart rate (HR), so corrected values for HR were used for this study. Various degrees of disturbance in diastolic filling were found in many cases without systolic impairment. According to the mechanism responsible for diastolic impairment, LV time activity curve showed a characteristic pattern. In IHD, filling disturbance in early diastole was observed before the impairment of systolic contraction developed, so it was thought to be an early predictor of cardiac failure. In the scar region of myocardial infarction (MI), decrease in regional ejection fraction and asynchrony in wall motion were shown, and these resulted in marked deterioration of early diastolic filling. On the other hand in angina pectoris (AP), such systolic disorders were not shown in the ischemic region perfused by stenotic coronary artery, although the disturbance of regional filling was found. The exercise capacity in AP was more related to the impairment in diastolic function at resting state than in systolic function, and furthermore the reserve of diastolic function as well as of systolic function was shown to be an important determinant of exercise capacity in AP. As HR increased, increase of PFR and decrease in time to peak filling was found, which was thought to be a sort of compensation for the shortening diastolic time due to increase in HR during exercise. Such compensation was decreased in AP with reduced exercise capacity. (J.P.N.)
Fractional Schroedinger equation
International Nuclear Information System (INIS)
Laskin, Nick
2002-01-01
Some properties of the fractional Schroedinger equation are studied. We prove the Hermiticity of the fractional Hamilton operator and establish the parity conservation law for fractional quantum mechanics. As physical applications of the fractional Schroedinger equation we find the energy spectra of a hydrogenlike atom (fractional 'Bohr atom') and of a fractional oscillator in the semiclassical approximation. An equation for the fractional probability current density is developed and discussed. We also discuss the relationships between the fractional and standard Schroedinger equations
Povstenko, Yuriy
2015-01-01
This book is devoted to fractional thermoelasticity, i.e. thermoelasticity based on the heat conduction equation with differential operators of fractional order. Readers will discover how time-fractional differential operators describe memory effects and space-fractional differential operators deal with the long-range interaction. Fractional calculus, generalized Fourier law, axisymmetric and central symmetric problems and many relevant equations are featured in the book. The latest developments in the field are included and the reader is brought up to date with current research. The book contains a large number of figures, to show the characteristic features of temperature and stress distributions and to represent the whole spectrum of order of fractional operators. This work presents a picture of the state-of-the-art of fractional thermoelasticity and is suitable for specialists in applied mathematics, physics, geophysics, elasticity, thermoelasticity and engineering sciences. Corresponding sections of ...
International Nuclear Information System (INIS)
Zhang, JY; Hong, DL
2016-01-01
Purpose: To investigate the impact of bladder filling status of the organs at risk (OARs) on dose distribution during intensity modulated radiotherapy (IMRT) for cervical cancer patients. Methods: Twelve cervical cancer patients treated with IMRT were selected for this study. The prescription dose was 45Gy/25 fractions with the 6 MV photon beam. All patients performed two CT scans, one with an empty bladder, the other one with bladder filled. For the registration of two CT scans, the fusion was automatically carried out upon the bony anatomy. The OARs (bladder, rectum, pelvic bone and small intestine) were delineated to planning CT to evaluate the dose distributions. These dose distributions were compared between empty bladder and bladder filling. Results: The bladder volume with empty bladder and bladder filling was 403.2±124.13cc and 101.4±87.5cc, respectively. There were no statistical differences between empty bladder and bladder filling in the mean value of pelvic bone V10Gy, V20Gy, V40Gy; rectum V40Gy and V45Gy. The bladder V40Gy and V45Gy were lower in the bladder filling group than in the empty bladder group (63.7%±5.8% vs 87.5%±7.8%, 45.1%±9.5% vs 62.4%±11.8%, respectively). The V45Gy for small intestine in the bladder filling group was significantly less than the empty bladder group (146.7cc±95.3cc vs 245.7cc±101.8cc). Conclusion: Our study finds that the bladder filling status did not have a significant impact on dose distribution in the rectum and pelvic bone. However, the changes of bladder filling have a large impact on bladder and small intestine doses. A full bladder is strongly recommended during treatment for cervical cancer patients.
Energy Technology Data Exchange (ETDEWEB)
Zhang, JY [Cancer Hospital of Shantou University Medical College, Shantou, Guangdong (China); Hong, DL [The First Affiliated Hospital of Shantou University Medical College, Shantou, Guangdong (China)
2016-06-15
Purpose: To investigate the impact of bladder filling status of the organs at risk (OARs) on dose distribution during intensity modulated radiotherapy (IMRT) for cervical cancer patients. Methods: Twelve cervical cancer patients treated with IMRT were selected for this study. The prescription dose was 45Gy/25 fractions with the 6 MV photon beam. All patients performed two CT scans, one with an empty bladder, the other one with bladder filled. For the registration of two CT scans, the fusion was automatically carried out upon the bony anatomy. The OARs (bladder, rectum, pelvic bone and small intestine) were delineated to planning CT to evaluate the dose distributions. These dose distributions were compared between empty bladder and bladder filling. Results: The bladder volume with empty bladder and bladder filling was 403.2±124.13cc and 101.4±87.5cc, respectively. There were no statistical differences between empty bladder and bladder filling in the mean value of pelvic bone V10Gy, V20Gy, V40Gy; rectum V40Gy and V45Gy. The bladder V40Gy and V45Gy were lower in the bladder filling group than in the empty bladder group (63.7%±5.8% vs 87.5%±7.8%, 45.1%±9.5% vs 62.4%±11.8%, respectively). The V45Gy for small intestine in the bladder filling group was significantly less than the empty bladder group (146.7cc±95.3cc vs 245.7cc±101.8cc). Conclusion: Our study finds that the bladder filling status did not have a significant impact on dose distribution in the rectum and pelvic bone. However, the changes of bladder filling have a large impact on bladder and small intestine doses. A full bladder is strongly recommended during treatment for cervical cancer patients.
Methane productivity of manure, straw and solid fractions of manure
DEFF Research Database (Denmark)
Møller, H.B.; Sommer, S.G.; Ahring, Birgitte Kiær
2004-01-01
are in the same range (282-301 m(3) CH4 LU-1). Pre-treatment of manure by separation is a way of making fractions of the manure that have a higher gas potential per volume. Theoretical methane potential and biodegradability of three types of fractions deriving from manure separation were tested. The volumetric...... methane yield of straw was found to be higher than the yield from total manure and the solid fractions of manure, due to the higher VS content, and hence the use of straw as bedding material will increase the volumetric as well as the livestock-based methane productivity....
46 CFR 151.03-21 - Filling density.
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Filling density. 151.03-21 Section 151.03-21 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES BARGES CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Definitions § 151.03-21 Filling density. The ratio, expressed as...
Microtensile bond strength of bulk-fill restorative composites to dentin.
Mandava, Jyothi; Vegesna, Divya-Prasanna; Ravi, Ravichandra; Boddeda, Mohan-Rao; Uppalapati, Lakshman-Varma; Ghazanfaruddin, M D
2017-08-01
To facilitate the easier placement of direct resin composite in deeper cavities, bulk fill composites have been introduced. The Mechanical stability of fillings in stress bearing areas restored with bulk-fill resin composites is still open to question, since long term clinical studies are not available so far. Thus, the objective of the study was to evaluate and compare the microtensile bond strength of three bulk-fill restorative composites with a nanohybrid composite. Class I cavities were prepared on sixty extracted mandibular molars. Teeth were divided into 4 groups (n= 15 each) and in group I, the prepared cavities were restored with nanohybrid (Filtek Z250 XT) restorative composite in an incremental manner. In group II, III and IV, the bulk-fill composites (Filtek, Tetric EvoCeram, X-tra fil bulk-fill restoratives) were placed as a 4 mm single increment and light cured. The restored teeth were subjected to thermocycling and bond strength testing was done using instron testing machine. The mode of failure was assessed by scanning electron microscope (SEM). The bond strength values obtained in megapascals (MPa) were subjected to statistical analysis, using SPSS/PC version 20 software.One-way ANOVA was used for groupwise comparison of the bond strength. Tukey's Post Hoc test was used for pairwise comparisons among the groups. The highest mean bond strength was achieved with Filtek bulk-fill restorative showing statistically significant difference with Tetric EvoCeram bulk-fill ( p composites. Adhesive failures are mostly observed with X-tra fil bulk fill composites, whereas mixed failures are more common with other bulk fill composites. Bulk-fill composites exhibited adequate bond strength to dentin and can be considered as restorative material of choice in posterior stress bearing areas. Key words: Bond strength, Bulk-fill restoratives, Configuration factor, Polymerization shrinkage.
tongqing, Wu; liang, Li; xinjian, Liu; Xu, nianchun; Tian, Mao
2018-03-01
Self-balanced method is carried out on the large diameter rock-socketed filling piles of high-pile wharf at Inland River, to explore the distribution laws of load-displacement curve, pile internal force, pile tip friction resistance and pile side friction resistance under load force. The results showed that: the tip resistance of S1 and S2 test piles accounted for 53.4% and 53.6% of the pile bearing capacity, respectively, while the total side friction resistance accounted for 46.6% and 46.4% of the pile bearing capacity, respectively; both the pile tip friction resistance and pile side friction resistance can be fully played, and reach to the design requirements. The reasonability of large diameter rock-socketed filling design is verified through test analysis, which can provide basis for the optimization of high-pile wharf structural type, thus reducing the wharf project cost, and also providing reference for the similar large diameter rock-socketed filling piles of high-pile wharf at Inland River.
Lipid peroxidation inhibition and antiradical activities of some leaf fractions of Mangifera indica.
Badmus, Jelili A; Adedosu, Temitope O; Fatoki, John O; Adegbite, Victor A; Adaramoye, Oluwatosin A; Odunola, Oyeronke A
2011-01-01
This study was undertaken to assess in vitro lipid peroxidation inhibitions and anti-radical activities of methanolic, chloroform, ethyl acetate and water fractions of Mangifera indica leaf. Inhibition of Fe(2+)-induced lipid peroxidation (LPO) in egg, brain, and liver homogenates, 1,1-diphenyl-2-picrylhydrazyl (DPPH) and hydroxyl (OH-) radical scavenging activities were evaluated. Total phenol was assessed in all fractions, and the reducing power of methanolic fraction was compared to gallic acid and ascorbic acid. The results showed that Fe2+ induced significant lipid peroxidation (LPO) in all the homogenates. Ethyl acetate fraction showed the highest percentage inhibition of LPO in both egg yolk (68.3%) and brain (66.3%), while the aqueous fraction exerted the highest inhibition in liver homogenate (89.1%) at a concentration of 10 microg/mL. These observed inhibitions of LPO by these fractions were higher than that of ascorbic acid used as a standard. The DPPH radical scavenging ability exhibited by ethyl acetate fraction was found to be the highest with IC50 value of 1.5 microg/mL. The ethyl acetate and methanolic fractions had the highest OH- radical scavenging ability with the same IC50 value of 5 microg/mL. The total phenol content of ethyl acetate fraction was the highest with 0.127 microg/mg gallic acid equivalent (GAE). The reductive potential of methanolic fraction showed a concentration-dependent increase. This study showed that inhibition of LPO and the DPPH and OH- radicals scavenging abilities of Mangifera indica leaf could be related to the presence of phenolic compounds. Therefore, the ethyl acetate fraction of the leaf may be a good source of natural antioxidative agent.
Directory of Open Access Journals (Sweden)
Neslihan Simsek
2014-01-01
Full Text Available The aim of this study was to compare the efficacy of D-RaCe files and a self-adjusting file (SAF system in removing filling material from curved root canals instrumented and filled with different techniques by using microcomputed tomography (micro-CT. The mesial roots of 20 extracted mandibular first molars were used. Root canals (mesiobuccal and mesiolingual were instrumented with SAF or Revo-S. The canals were then filled with gutta-percha and AH Plus sealer using cold lateral compaction or thermoplasticized injectable techniques. The root fillings were first removed with D-RaCe (Step 1, followed by Step 2, in which a SAF system was used to remove the residual fillings in all groups. Micro-CT scans were used to measure the volume of residual filling after root canal filling, reinstrumentation with D-RaCe (Step 1, and reinstrumentation with SAF (Step 2. Data were analyzed using Wilcoxon and Kruskal-Wallis tests. There were no statistically significant differences between filling techniques in the canals instrumented with SAF (P=0.292 and Revo-S (P=0.306. The amount of remaining filling material was similar in all groups (P=0.363; all of the instrumentation techniques left filling residue inside the canals. However, the additional use of SAF was more effective than using D-RaCe alone.
Directory of Open Access Journals (Sweden)
Fernando Cidade Torres
2012-08-01
Full Text Available The aim of this work was to study the influence of essential oil fractionation on acaricidal activity against the cattle tick Rhipicephalus (Boophilus microplus. The citronella (Cymbopogon winterianus J. and pepper tree (Schinus molle L. essential oils were fractionated by vacuum distillation yielding fractions that were analyzed by the GC/MS. Laboratory tests were carried out to determine the effect of the total essential oil and fractions on larvae of the cattle tick R. (B. microplus. The fractions 04 and 05 of the C. winterianus essential oil were the most active showing LC50 values of 1.20 and 1.34 μL/mL, respectively. The LC50 of the total oil was 3.30 μL/mL while the effect of the fractions 01, 02 and 03 was less pronounced, with LC50 values of 4.37, 4.24 and 3.49 μL/mL, respectively. The fraction 03 of the S. molle essential oil was the most active showing LC50 value of 8.80 μL/mL while the fractions 01 and 02 did not show toxic effects on the larvae.
The indication and the point at issue in total body irradiation (TBI)
International Nuclear Information System (INIS)
Kikuchi, Yuzo; Nishino, Shigeo.
1992-01-01
The role of radiation in the cause of interstitial pneumonitis (IP) was analysed here. Also optimal dose fractionation was discussed about total absorbed lung dose, dose rate and fractionation in spect of IP. After all optimal time schedule was recommended 3, 4 and 6 fraction of ≤ 4 Gy of fraction size using conventional and hyperfractionated irradiation. In the end the present condition and the point at issue in the irradiation of blood for prevention GVHD were discussed. (author)
Directory of Open Access Journals (Sweden)
Rzymski Piotr
2015-03-01
Full Text Available Urban reservoirs can receive high loads of chemicals, including persistent contaminants and eutrophication-promoting nutrients. To maintain their economic and recreational use, implementation of various restoration methods is often required. The Maltański Reservoir (Poland, Europe, a small, shallow and dammed urban water body, undergoes complete draining every four years as part of its restoration procedure. Here, we investigated the phosphorus (P content and its fractions just before the reservoir was drained and after it had been completely filled with water again. As demonstrated, the highest accumulation of P occurred at sites through which the main water flow is directed. Calcium-bound and residual P constituted the largest proportion of P fractions. A shift in P fractions after the reservoir was drained and sediments were left without water for at least 4 months was observed. A decrease in phytoplankton utilized NH4Cl-P, Fe-P and NaOH-P fractions was found and followed a simultaneous increase in nearly biologically inaccessible HCl-P and practically biologically inactive residual P fractions. Our study demonstrates that complete drainage of the Maltański Reservoir may additionally decrease the risk of internal P loading through shifts in its fractions.
Multigated radionuclide study of the total artificial heart
International Nuclear Information System (INIS)
Datz, F.L.; Christian, P.E.; Taylor, A. Jr.; Hastings, W.L.; De Vries, W.C.
1987-01-01
A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent. (orig.)
Multigated radionuclide study of the total artificial heart
Energy Technology Data Exchange (ETDEWEB)
Datz, F L; Christian, P E; Taylor, A Jr; Hastings, W L; De Vries, W C
1987-07-01
A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent.
Laskin, Nick
2018-01-01
Fractional quantum mechanics is a recently emerged and rapidly developing field of quantum physics. This is the first monograph on fundamentals and physical applications of fractional quantum mechanics, written by its founder. The fractional Schrödinger equation and the fractional path integral are new fundamental physical concepts introduced and elaborated in the book. The fractional Schrödinger equation is a manifestation of fractional quantum mechanics. The fractional path integral is a new mathematical tool based on integration over Lévy flights. The fractional path integral method enhances the well-known Feynman path integral framework. Related topics covered in the text include time fractional quantum mechanics, fractional statistical mechanics, fractional classical mechanics and the α-stable Lévy random process. The book is well-suited for theorists, pure and applied mathematicians, solid-state physicists, chemists, and others working with the Schrödinger equation, the path integral technique...
Physico-mechanical characteristics of commercially available bulk-fill composites.
Leprince, Julian G; Palin, William M; Vanacker, Julie; Sabbagh, Joseph; Devaux, Jacques; Leloup, Gaetane
2014-08-01
Bulk-fill composites have emerged, arguably, as a new "class" of resin-based composites, which are claimed to enable restoration in thick layers, up to 4mm. The objective of this work was to compare, under optimal curing conditions, the physico-mechanical properties of most currently available bulk-fill composites to those of two conventional composite materials chosen as references, one highly filled and one flowable "nano-hybrid" composite. Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent), Venus Bulk Fill (Heraeus-Kulzer), SDR (Dentsply), X-tra Fil (VOCO), X-tra Base (VOCO), Sonic Fill (Kerr), Filtek Bulk Fill (3M-Espe), Xenius (GC) were compared to the two reference materials. The materials were light-cured for 40s in a 2mm×2mm×25mm Teflon mould. Degree of conversion was measured by Raman spectroscopy, Elastic modulus and flexural strength were evaluated by three point bending, surface hardness using Vickers microindentation before and after 24h ethanol storage, and filler weight content by thermogravimetric analysis. The ratio of surface hardness before and after ethanol storage was considered as an evaluation of polymer softening. Data were analyzed by one-way ANOVA and post hoc Tukey's test (p=0.05). The mechanical properties of the bulk-fill composites were mostly lower compared with the conventional high viscosity material, and, at best, comparable to the conventional flowable composite. Linear correlations of the mechanical properties investigated were poor with degree of conversion (0.090.8). Softening in ethanol revealed differences in polymer network density between material types. The reduction of time and improvement of convenience associated with bulk-fill materials is a clear advantage of this particular material class. However, a compromise with mechanical properties compared with more conventional commercially-available nano-hybrid materials was demonstrated by the present work. Given the lower mechanical properties of most bulk-fill materials
21 CFR 872.3310 - Coating material for resin fillings.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coating material for resin fillings. 872.3310... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3310 Coating material for resin fillings. (a) Identification. A coating material for resin fillings is a device intended to be applied to the...
Mixed convective magnetohydrodynamic flow in a vertical channel filled with nanofluids
Directory of Open Access Journals (Sweden)
S. Das
2015-06-01
Full Text Available The fully developed mixed convection flow in a vertical channel filled with nanofluids in the presence of a uniform transverse magnetic field has been studied. Closed form solutions for the fluid temperature, velocity and induced magnetic field are obtained for both the buoyancy-aided and -opposed flows. Three different water-based nanofluids containing copper, aluminium oxide and titanium dioxide are taken into consideration. Effects of the pertinent parameters on the nanofluid temperature, velocity, and induced magnetic field as well as the shear stress and the rate of heat transfer at the channel wall are shown in figures and tables followed by a quantitative discussion. It is found that the magnetic field tends to enhance the nanofluid velocity in the channel. The induced magnetic field vanishes in the cental region of the channel. The critical Rayleigh number at onset of instability of flow is strongly dependent on the volume fraction of nanoparticles and the magnetic field.
Impact of radiation therapy fraction size on local control of early glottic carcinoma
International Nuclear Information System (INIS)
Yu, Edward; Shenouda, George; Beaudet, Marie P.; Black, Martin J.
1997-01-01
Purpose: Different radiotherapy fractionation schedules were used over a 10-year period to treat patients with early squamous cell carcinoma of the vocal cords at McGill University. A retrospective analysis was performed to study the effect of fraction size on local control in this group of patients. Methods and Materials: A total of 126 previously untreated patients with T1 invasive squamous cell carcinoma of the true vocal cords were irradiated between January 1978 and December 1988 in the Department of Radiation Oncology at McGill University. All patients received megavoltage irradiation, 94 patients received daily fractions > 2 Gy (64 patients received 50 Gy with once-daily 2.5-Gy fractions, and 30 received 65.25 Gy in 29 fractions of 2.25 Gy each), and 32 patients were treated to a dose of 66 Gy in 33 fractions with 2 Gy/fraction. Patients' characteristics of prognostic importance were equally distributed between the two fractionation groups. Results: At a median follow-up of 84 months, the 10-year disease-free survival and overall survival were 76% and 93%, respectively. Local control for patients treated with > 2 Gy fraction was 84%, compared to 65.6% for those treated with 2-Gy fractions (p = 0.026). Among the prognostic factors tested, such as gender, age, stage, anterior and posterior commissure involvement, smoking history, and fraction size, the latter was the only significant predictor of local control for the whole group of patients in univariate (p = 0.041) and multivariate (p = 0.023) analysis. There was no observed difference in the incidence of complications between the two fraction groups. Conclusions: From the results of this retrospective review of patients treated with radiotherapy for T1 true vocal cord cancer, and within the range of total doses and overall treatment times used in our patients, it was found that fractionation schedules using daily fraction size > 2 Gy are associated with a better local control than schedules delivering 2 Gy/fraction
Effect of reflection losses on stationary dielectric-filled nonimaging concentrators
Madala, Srikanth; Boehm, Robert F.
2016-10-01
The effect of Fresnel reflection and total internal reflection (TIR) losses on the performance parameters in refractive solar concentrators has often been downplayed because most refractive solar concentrators are traditionally the imaging type, yielding a line or point image on the absorber surface when solely interacted with paraxial etendue ensured by solar tracking. Whereas, with refractive-type nonimaging solar concentrators that achieve two-dimensional (rectangular strip) focus or three-dimensional (circular or elliptical) focus through interaction with both paraxial and nonparaxial etendue within the acceptance angle, the Fresnel reflection and TIR losses are significant as they will affect the performance parameters and, thereby, energy collection. A raytracing analysis has been carried out to illustrate the effects of Fresnel reflection and TIR losses on four different types of stationary dielectric-filled nonimaging concentrators, namely V-trough, compound parabolic concentrator, compound elliptical concentrator, and compound hyperbolic concentrator. The refractive index (RI) of a dielectric fill material determines the acceptance angle of a solid nonimaging collector. Larger refractive indices yield larger acceptance angles and, thereby, larger energy collection. However, they also increase the Fresnel reflection losses. This paper also assesses the relative benefit of increasing RI from an energy collection standpoint.
International Nuclear Information System (INIS)
Pors Nielsen, S.; Baerenholdt, O.; Munck, O.
1975-01-01
By application of a power function model, fractional intestinal calcium absorption was investigated with a new technique involving whole-body counting after successive oral and intravenous administration of standard doses of 47 Ca. The fractional calcium retention 7 days after the oral load of 47 Ca was also measured. Fractional calcium retention averaged 30.3% in normal subjects and 11.5% in 11 patients with intestinal malabsorption. In the same groups fractional calcium absorption averaged 46.6% and 16.4%, respectively. Fractional calcium retention and intestinal calcium absorption were significantly correlated to body surface area, and there was a well-defined relation between fractional retention and absorption of calcium. These studies demonstrate that measurements of fractional retention and fractional intestinal absorption of calcium can be combined by the use of a whole-body counter, that fractional retention and intestinal absorption are proportional to total body surface area and therefore probably also to the total bone mass, and that fractional retention and absorption are so closely interrelated that frational absorption can be estimated from fractional retention with reasonable accuracy in normal subjects. (auth.)
Toughening Mechanisms in Silica-Filled Epoxy Nanocomposites
Patel, Binay S.
Epoxies are widely used as underfill resins throughout the microelectronics industry to mechanically couple and protect various components of flip-chip assemblies. Generally rigid materials largely surround underfill resins. Improving the mechanical and thermal properties of epoxy resins to better match those of their rigid counterparts can help extend the service lifetime of flip-chip assemblies. Recently, researchers have demonstrated that silica nanoparticles are effective toughening agents for lightly-crosslinked epoxies. Improvements in the fracture toughness of silica-filled epoxy nanocomposites have primarily been attributed to two toughening mechanisms: particle debonding with subsequent void growth and matrix shear banding. Various attempts have been made to model the contribution of these toughening mechanisms to the overall fracture energy observed in silica-filled epoxy nanocomposites. However, disparities still exist between experimental and modeled fracture energy results. In this dissertation, the thermal, rheological and mechanical behavior of eight different types of silica-filled epoxy nanocomposites was investigated. Each nanocomposite consisted of up to 10 vol% of silica nanoparticles with particle sizes ranging from 20 nm to 200 nm, with a variety of surface treatments and particle structures. Fractographical analysis was conducted with new experimental approaches in order to accurately identify morphological evidence for each proposed toughening mechanism. Overall, three major insights into the fracture behavior of real world silica-filled epoxy nanocomposites were established. First, microcracking was observed as an essential toughening mechanism in silica-filled epoxy nanocomposites. Microcracking was observed on the surface and subsurface of fractured samples in each type of silica-filled epoxy nanocomposite. The additional toughening contribution of microcracking to overall fracture energy yielded excellent agreement between experimental
Dural sinus filling defect: intrasigmoid encephalocele
Karatag, Ozan; Cosar, Murat; Kizildag, Betul; Sen, Halil Murat
2013-01-01
Filling defects of dural venous sinuses are considered to be a challenging problem especially in case of symptomatic patients. Many lesions have to be ruled out such as sinus thrombosis, arachnoid granulations and tumours. Encephalocele into dural sinus is also a rare cause of these filling defects of dural sinuses. Here, we report an extremely rare case with spontaneous occult invagination of temporal brain tissue into the left sigmoid sinus and accompanying cerebellar ectopia. PMID:24311424
Rita, Joice Cleide O; Gama-Rodrigues, Emanuela Forestieri; Gama-Rodrigues, Antonio Carlos; Polidoro, Jose Carlos; Machado, Regina Cele R; Baligar, Virupax C
2011-07-01
Agroforestry systems (AFSs) have an important role in capturing above and below ground soil carbon and play a dominant role in mitigation of atmospheric CO(2). Attempts has been made here to identify soil organic matter fractions in the cacao-AFSs that have different susceptibility to microbial decomposition and further represent the basis of understanding soil C dynamics. The objective of this study was to characterize the organic matter density fractions and soil size fractions in soils of two types of cacao agroforestry systems and to compare with an adjacent natural forest in Bahia, Brazil. The land-use systems studied were: (1) a 30-year-old stand of natural forest with cacao (cacao cabruca), (2) a 30-year-old stand of cacao with Erythrina glauca as shade trees (cacao + erythrina), and (3) an adjacent natural forest without cacao. Soil samples were collected from 0-10 cm depth layer in reddish-yellow Oxisols. Soil samples was separated by wet sieving into five fraction-size classes (>2000 μm, 1000-2000 μm, 250-1000 μm, 53-250 μm, and 2000 μm) mixed with macroaggregates (32-34%), and microaggregates (1-1.3%). Soil organic carbon (SOC) and total N content increased with increasing soil size fraction in all land-use systems. Organic C-to-total N ratio was higher in the macroaggregate than in the microaggregate. In general, in natural forest and cacao cabruca the contribution of C and N in the light and heavy fractions was similar. However, in cacao + erythrina the heavy fraction was the most common and contributed 67% of C and 63% of N. Finding of this study shows that the majority of C and N in all three systems studied are found in macroaggregates, particularly in the 250-1000 μm size aggregate class. The heavy fraction was the most common organic matter fraction in these soils. Thus, in mature cacao AFS on highly weathered soils the main mechanisms of C stabilization could be the physical protection within macroaggregate structures thereby
Rita, Joice Cleide O.; Gama-Rodrigues, Emanuela Forestieri; Gama-Rodrigues, Antonio Carlos; Polidoro, Jose Carlos; Machado, Regina Cele R.; Baligar, Virupax C.
2011-07-01
Agroforestry systems (AFSs) have an important role in capturing above and below ground soil carbon and play a dominant role in mitigation of atmospheric CO2. Attempts has been made here to identify soil organic matter fractions in the cacao-AFSs that have different susceptibility to microbial decomposition and further represent the basis of understanding soil C dynamics. The objective of this study was to characterize the organic matter density fractions and soil size fractions in soils of two types of cacao agroforestry systems and to compare with an adjacent natural forest in Bahia, Brazil. The land-use systems studied were: (1) a 30-year-old stand of natural forest with cacao (cacao cabruca), (2) a 30-year-old stand of cacao with Erythrina glauca as shade trees (cacao + erythrina), and (3) an adjacent natural forest without cacao. Soil samples were collected from 0-10 cm depth layer in reddish-yellow Oxisols. Soil samples was separated by wet sieving into five fraction-size classes (>2000 μm, 1000-2000 μm, 250-1000 μm, 53-250 μm, and cacao AFS soils consisted mainly (65 %) of mega-aggregates (>2000 μm) mixed with macroaggregates (32-34%), and microaggregates (1-1.3%). Soil organic carbon (SOC) and total N content increased with increasing soil size fraction in all land-use systems. Organic C-to-total N ratio was higher in the macroaggregate than in the microaggregate. In general, in natural forest and cacao cabruca the contribution of C and N in the light and heavy fractions was similar. However, in cacao + erythrina the heavy fraction was the most common and contributed 67% of C and 63% of N. Finding of this study shows that the majority of C and N in all three systems studied are found in macroaggregates, particularly in the 250-1000 μm size aggregate class. The heavy fraction was the most common organic matter fraction in these soils. Thus, in mature cacao AFS on highly weathered soils the main mechanisms of C stabilization could be the physical
Grain-filling duration and grain yield relationships in wheat mutants
International Nuclear Information System (INIS)
Larik, A.S.
1987-01-01
Nine stable mutants of bread wheat along with their mother cultivars were investigated for grain-filling characteristics in relation to grain yield. Significant differences among mutants for grain-filling duration and grain-filling index were observed. Inspite of the consistent differences in grain-filling duration there was no significant association between grain-filling duration and grain yield in C-591 and Nayab mutants. Failure to detect an yield advantage due to differences in grain-filling duration in these genotypes suggests that any advantage derived from alteration of grain-filling period may have been outweighed by the coincident changes in length of the vegetative period. Other factors such as synchrony of anthesis may have limited out ability to find an association between grainfilling duration and grain yield. On the contrary, significant association between grain-filling duration and grain yield displayed by indus-66 indus-66 mutants derived from gamma rays, shows the ability of gamma rays to induce functional alternations in the pattern of gene arrangements controlling these traits. Thus, the vaability observed in these physiological traits suggests that selection for these traits could be useful in improving grain yield. (author)
QENS investigation of filled rubbers
Triolo, A; Desmedt, A; Pieper, J K; Lo Celso, F; Triolo, R; Negroni, F; Arrighi, V; Qian, H; Frick, B
2002-01-01
The polymer segmental dynamics is investigated in a series of silica-filled rubbers. The presence of inert fillers in polymers greatly affects the mechanical and physical performance of the final materials. For example, silica has been proposed as a reinforcing agent of elastomers in tire production. Results from quasielastic neutron scattering and Dynamic Mechanical Thermal Analysis (DMTA) measurements are presented on styrene-ran-butadiene rubber filled with silica. A clear indication is obtained of the existence of a bimodal dynamics, which can be rationalized in terms of the relaxation of bulk rubber and the much slower relaxation of the rubber adsorbed on the filler surface. (orig.)
Alam, Md Ariful; Zaidul, I S M; Ghafoor, Kashif; Sahena, F; Hakim, M A; Rafii, M Y; Abir, H M; Bostanudin, M F; Perumal, V; Khatib, A
2017-03-31
This study was aimed to evaluate antioxidant and α-glucosidase inhibitory activity, with a subsequent analysis of total phenolic and total flavonoid content of methanol extract and its derived fractions from Clinacanthus nutans accompanied by comprehensive phytochemical profiling. Liquid-liquid partition chromatography was used to separate methanolic extract to get hexane, ethyl acetate, butanol and residual aqueous fractions. The total antioxidant activity was determined by 2,2-diphenyl-1-picrylhydrazy (DPPH) radical scavenging and ferric reducing antioxidant power assay (FRAP). The antidiabetic activity of methanol extract and its consequent fractions were examined by α-glucosidase inhibitory bioassay. The chemical profiling was carried out by gas chromatography coupled with quadrupole time-of-flight mass spectrometry (GC Q-TOF MS). The total yield for methanol extraction was (12.63 ± 0.98) % (w/w) and highest fractionated value found for residual aqueous (52.25 ± 1.01) % (w/w) as compared to the other fractions. Significant DPPH free radical scavenging activity was found for methanolic extract (63.07 ± 0.11) % and (79.98 ± 0.31) % for ethyl acetate fraction among all the fractions evaluated. Methanol extract was the most prominent in case of FRAP (141.89 ± 0.87 μg AAE/g) whereas most effective reducing power observed in ethyl acetate fraction (133.6 ± 0.2987 μg AAE/g). The results also indicated a substantial α-glucosidase inhibitory activity for butanol fraction (72.16 ± 1.0) % and ethyl acetate fraction (70.76 ± 0.49) %. The statistical analysis revealed that total phenolic and total flavonoid content of the samples had the significant (p < 0.05) impact on DPPH free radical scavenging and α-glucosidase inhibitory activity. Current results proposed the therapeutic potential of Clinacanthus nutans, especially ethyl acetate and butanol fraction as chemotherapeutic agent against oxidative related cellular damages and control the
International Nuclear Information System (INIS)
JOHNSON, B.L.; MOON, JEONG-SUN; RENO, JOHN L.; SIMMONS, JERRY A.
1999-01-01
The propagation direction of fractional quantum Hall effect (FQHE) edge states has been investigated experimentally via the symmetry properties of the multi-terminal capacitances of a two dimensional electron gas. Although strong asymmetries with respect to zero magnetic field appear, no asymmetries with respect to even denominator Landau level filling factor ν are seen. This indicates that current-carrying FQHE edge states propagate in the same direction as integer QHE edge states. In addition, anomalous capacitance features, indicative of enhanced bulk conduction, are observed at ν = 1/2 and 3/2
Energy Technology Data Exchange (ETDEWEB)
Carlier, Thomas, E-mail: thomas.carlier@chu-nantes.fr [Department of Nuclear Medicine, University Hospital of Nantes, Place Alexis Ricordeau, Nantes 44093, France and CRCNA–UMR 892 INSERM 6299 CNRS, 8 quai Moncousu BP 70721, Nantes 44007 (France); Willowson, Kathy P. [Institute of Medical Physics, University of Sydney, Camperdown, New South Wales 2006 (Australia); Fourkal, Eugene [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States); Bailey, Dale L. [Faculty of Health Sciences, University of Sydney, Lidcombe 2141, Australia and Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, New South Wales 2065 (Australia); Doss, Mohan [Department of Diagnostic Imaging, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States); Conti, Maurizio [Siemens Healthcare Molecular Imaging, 810 Innovation Drive, Knoxville, Tennessee 37932 (United States)
2015-07-15
Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely
Directory of Open Access Journals (Sweden)
Duan Pham Ngoc
2015-04-01
Full Text Available Objective: To characterize immunogenic protein fraction of Clonorchis sinensis (C. sinensis by partial purification. Methods: A total of 30 hamsters were infected with 50 C. sinensis metacercariae, and then C. sinensis protein was purified by gel filtration chromatography. Indirect ELISA and immunoblot were used to detect the antibody in sera of hamsters infected with C. sinensis. Results: The gel filtration showed 2 peaks at high (fraction No. 10 to 14 and low (fraction No. 21 to 26 molecular weight proteins. Indirect ELISA showed that both antibodies of clonorchiasis and opisthorchiasis reacted strongly with early fractions (6 to 14 and the reaction was gradually reduced at middle and late fractions (15 to 50. Both antibodies showed different individual fraction of C. sinensis by immunoblot. It showed several protein bands that the 34 and 37 kDa were major proteins. The 53 kDa protein which was only found in the clonorchiasis reacted with fraction 20. Conclusions: The purified antigen of C. sinensis reacted similarly with both antibodies of clonorchiasis and opisthorchiasis where strong reaction was seen with early fractions. The C. sinensis protein fraction No. 20 may be useful for immunodiagnosis of clonorchiasis.
Post-cure depth of cure of bulk fill dental resin-composites.
Alrahlah, A; Silikas, N; Watts, D C
2014-02-01
To determine the post-cure depth of cure of bulk fill resin composites through using Vickers hardness profiles (VHN). Five bulk fill composite materials were examined: Tetric EvoCeram(®) Bulk Fill, X-tra base, Venus(®) Bulk Fill, Filtek™ Bulk Fill, SonicFill™. Three specimens of each material type were prepared in stainless steel molds which contained a slot of dimensions (15 mm × 4 mm × 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37°C for 24h, before measurement. The Vickers hardness was measured as a function of depth of material, at 0.3mm intervals. Data were analysed by one-way ANOVA using Tukey post hoc tests (α=0.05). The maximum VHN ranged from 37.8 to 77.4, whilst the VHN at 80% of max.VHN ranged from 30.4 to 61.9. The depth corresponding to 80% of max.VHN, ranged from 4.14 to 5.03 mm. One-way ANOVA showed statistically significant differences between materials for all parameters tested. SonicFill exhibited the highest VHN (pFill the lowest (p≤0.001). SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure (5.03 and 4.47 mm, respectively) and was significant's different from X-tra base, Venus Bulk Fill and Filtek Bulk Fill (p≤0.016). Linear regression confirmed a positive regression between max.VHN and filler loading (r(2)=0.94). Bulk fill resin composites can be cured to an acceptable post-cure depth, according to the manufacturers' claims. SonicFill and Tetric EvoCeram Bulk Fill had the greatest depth of cure among the composites examined. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Stability of fruit bases and chocolate fillings
Directory of Open Access Journals (Sweden)
Joice Natali Miquelim
2011-03-01
Full Text Available Syrups with high sugar content and dehydrated fruits in its composition can be added to chocolate fillings to reduce the need of artificial flavor and dyes attributing a natural appeal to the product. Fruit bases were produced with lyophilized strawberry, passion fruit, and sliced orange peel. Rheological dynamic oscillatory tests were applied to determine the products stability and tendency of shelf life. Values of G´ G´´ were found for orange flavor during the 90 days of storage. It was observed that shear stress values did not vary significantly suggesting product stability during the studied period. For all fillings, it was found a behavior similar to the fruit base indicating that it has great influence on the filling behavior and its stability. The use of a sugar matrix in fillings provided good shelf life for the fruit base, which could be kept under room temperature conditions for a period as long as one year. The good stability and storage conditions allow the use of fruit base for handmade products as well as for industrialized products.
46 CFR 98.25-50 - Filling and discharge pipes.
2010-10-01
... with a secondary remote control of a type acceptable to the Commandant. (c) The excess flow, internal... 46 Shipping 4 2010-10-01 2010-10-01 false Filling and discharge pipes. 98.25-50 Section 98.25-50... § 98.25-50 Filling and discharge pipes. (a) Filling connections shall be provided with one of the...
Energy Technology Data Exchange (ETDEWEB)
Sabzikar, Farzad, E-mail: sabzika2@stt.msu.edu [Department of Statistics and Probability, Michigan State University, East Lansing, MI 48823 (United States); Meerschaert, Mark M., E-mail: mcubed@stt.msu.edu [Department of Statistics and Probability, Michigan State University, East Lansing, MI 48823 (United States); Chen, Jinghua, E-mail: cjhdzdz@163.com [School of Sciences, Jimei University, Xiamen, Fujian, 361021 (China)
2015-07-15
Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series.
Sabzikar, Farzad; Meerschaert, Mark M.; Chen, Jinghua
2015-07-01
Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series.
International Nuclear Information System (INIS)
Sabzikar, Farzad; Meerschaert, Mark M.; Chen, Jinghua
2015-01-01
Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series
Convergent ablation measurements with gas-filled rugby hohlraum on OMEGA
International Nuclear Information System (INIS)
Casner, A.; Jalinaud, T.; Galmiche, D.
2016-01-01
Convergent ablation experiments with gas-filled rugby hohlraum were performed for the first time on the OMEGA laser facility. A time resolved 1D streaked radiography of capsule implosion is acquired in the direction perpendicular to hohlraum axis, whereas a 2D gated radiography is acquired at the same time along the hohlraum axis on a x-ray framing camera. The implosion trajectory has been measured for various kinds of uniformly doped ablators, including germanium-doped and silicon-doped polymers (CH), at two different doping fraction (2% and 4% at.). Our experiments aimed also at measuring the implosion performance of laminated capsules. A laminated ablator is constituted by thin alternate layers of un-doped and doped CH. It has been previously shown in planar geometry that laminated ablators could mitigate Rayleigh Taylor growth at ablation front. Our results confirm that the implosion of a capsule constituted with a uniform or laminated ablator behaves similarly, in accordance with post-shot simulations performed with the CEA hydrocode FCI2. (paper)
Excavation/Fill/Soil Disturbance, Self-Study #31419
Energy Technology Data Exchange (ETDEWEB)
Grogin, Phillip W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2018-02-06
This course, Excavation/Fill/Soil Disturbance Self-Study (#31419), presents an overview of the hazards, controls, and requirements that affect safe excavations at Los Alamos National Laboratory (LANL). An overview of the LANL excavation/fill/soil disturbance permit (EXID permit) approval process is also presented, along with potholing requirements for planning and performing excavations at LANL.
Off-Line High-pH Reversed-Phase Fractionation for In-Depth Phosphoproteomics
DEFF Research Database (Denmark)
Batth, Tanveer S; Francavilla, Chiara; Olsen, Jesper V
2014-01-01
thousands of phosphorylation sites. However, in-depth phosphoproteomics often require off-line enrichment and fractionation techniques. In this study, we provide a detailed analysis of the physicochemical characteristics of phosphopeptides, which have been fractionated by off-line high-pH chromatography (Hp...... phosphorylated peptides over that with SCX. Further optimizations in the pooling and concatenation strategy increased the total number of multiphosphorylated peptides detected after HpH fractionation. In conclusion, we provide a basic framework and resource for performing in-depth phosphoproteome studies...
Directory of Open Access Journals (Sweden)
W. Tillmann
2017-06-01
Full Text Available Tungsten carbide reinforced coatings play an important role in the field of surface engineering to protect stressed surfaces against wear. For thermally sprayed coatings, it is already shown that the tribological properties get mainly determined by the carbide grain size fraction. Within the scope of this study, the tribological characteristics of iron based WC-W2C reinforced arc sprayed coatings deposited using cored wires consisting of different carbide grain size fractions were examined. Microstructural characteristics of the produced coatings were scrutinized using electron microscopy and x-ray diffraction analyses. Ball-on-disk test as well as Taber Abraser and dry sand rubber wheel test were employed to analyze both the dry sliding and the abrasive wear behavior. It was shown that a reduced carbide grain size fraction as filling leads to an enhanced wear resistance against sliding. In terms of the Taber Abraser test, it is also demonstrated that a fine carbide grain size fraction results in an improved wear resistant against abrasion. As opposed to that, a poorer wear resistance was found within the dry sand rubber wheel tests. The findings show that the operating mechanisms for both abrasion tests affect the stressed surface in a different way, leading either to microcutting or microploughing.
Effect of land use on some soil chemical properties and P fractions ...
African Journals Online (AJOL)
Land use directly or indirectly affects the soil chemical properties and phosphorus fractions. Two different land use types were studied. Soil chemical analysis and phosphorus fractionation of the soils was then done and the results were highly significant (p<0.001). Total C, N and P were low under the arable land use as ...
Fractional Vector Calculus and Fractional Special Function
Li, Ming-Fan; Ren, Ji-Rong; Zhu, Tao
2010-01-01
Fractional vector calculus is discussed in the spherical coordinate framework. A variation of the Legendre equation and fractional Bessel equation are solved by series expansion and numerically. Finally, we generalize the hypergeometric functions.
A statistical treatment of bioassay pour fractions
Barengoltz, Jack; Hughes, David
A bioassay is a method for estimating the number of bacterial spores on a spacecraft surface for the purpose of demonstrating compliance with planetary protection (PP) requirements (Ref. 1). The details of the process may be seen in the appropriate PP document (e.g., for NASA, Ref. 2). In general, the surface is mechanically sampled with a damp sterile swab or wipe. The completion of the process is colony formation in a growth medium in a plate (Petri dish); the colonies are counted. Consider a set of samples from randomly selected, known areas of one spacecraft surface, for simplicity. One may calculate the mean and standard deviation of the bioburden density, which is the ratio of counts to area sampled. The standard deviation represents an estimate of the variation from place to place of the true bioburden density commingled with the precision of the individual sample counts. The accuracy of individual sample results depends on the equipment used, the collection method, and the culturing method. One aspect that greatly influences the result is the pour fraction, which is the quantity of fluid added to the plates divided by the total fluid used in extracting spores from the sampling equipment. In an analysis of a single sample’s counts due to the pour fraction, one seeks to answer the question: What is the probability that if a certain number of spores are counted with a known pour fraction, that there are an additional number of spores in the part of the rinse not poured. This is given for specific values by the binomial distribution density, where detection (of culturable spores) is success and the probability of success is the pour fraction. A special summation over the binomial distribution, equivalent to adding for all possible values of the true total number of spores, is performed. This distribution when normalized will almost yield the desired quantity. It is the probability that the additional number of spores does not exceed a certain value. Of course
Directory of Open Access Journals (Sweden)
Kaira E.S. da Silva-Leite
Full Text Available Abstract Ximenia americana L., Olacaceae, barks are utilized in folk medicine as analgesic and anti-inflammatory. The objective was to evaluate the toxicity and antinociceptive effect of polysaccharides rich fractions from X. americana barks. The fractions were obtained by extraction with NaOH, followed by precipitation with ethanol and fractionation by ion exchange chromatography. They were administered i.v. or p.o. before nociception tests (writhing, formalin, carragenan-induced hypernociception, hot plate, or during 14 days for toxicity assay. The total polysaccharides fraction (TPL-Xa: 8.1% yield presented 43% carbohydrate (21% uronic acid and resulted in two main fractions after chromatography (FI: 12%, FII: 22% yield. FII showed better homogeneity/purity, content of 44% carbohydrate, including 39% uronic acid, arabinose and galactose as major monosaccharides, and infrared spectra with peaks in carbohydrate range for COO- groups of uronic acid. TPL-Xa (10 mg/kg and FII (0.1 and 1 mg/kg presented inhibitory effect in behavior tests that evaluate nociception induced by chemical and mechanical, but not thermal stimuli. TPL-Xa did not alter parameters of systemic toxicity. In conclusion, polysaccharides rich fractions of X. americana barks inhibit peripheral inflammatory nociception, being well tolerated by animals.
Subrecoil laser cooling dynamics: a fractional derivative approach
International Nuclear Information System (INIS)
Uchaikin, Vladimir V; Sibatov, Renat T
2009-01-01
The subrecoil laser cooling process is considered in the framework of a model with two states (trapping and recycling), with instantaneous transitions between them. The key point of the work is the use of a fractional exponential function for waiting time distributions. This allows us to derive a general master equation covering both important cases: those with exponential and power type tails. Their solutions are expressed through fractionally stable distributions. The pdfs of the total trapping time of an atom and the proportion of trapped atoms are found. Analytical relationships show a good agreement with numerical results from Monte Carlo simulation
Crustal fraction of moment of inertia in pulsars
International Nuclear Information System (INIS)
Atta, Debasis; Mukhopadhyay, Somnath; Basu, D.N.
2015-01-01
In the present work, stability of the β-equilibrated dense nuclear matter is analyzed with respect to the thermodynamic stability conditions. Based on the density dependent M3Y (DDM3Y) effective nucleon-nucleon (NN) interaction, the location of the inner edge of neutron star crusts and core-crust transition density and pressure are calculated and crustal fraction of moment of inertia is determined. These results for pressure and density at core-crust transition together with the observed minimum crustal fraction of the total moment of inertia provide a new limit for the radius of the Vela pulsar
A New Filled Function Method with One Parameter for Global Optimization
Directory of Open Access Journals (Sweden)
Fei Wei
2013-01-01
Full Text Available The filled function method is an effective approach to find the global minimizer of multidimensional multimodal functions. The conventional filled functions are numerically unstable due to exponential or logarithmic term and sensitive to parameters. In this paper, a new filled function with only one parameter is proposed, which is continuously differentiable and proved to satisfy all conditions of the filled function definition. Moreover, this filled function is not sensitive to parameter, and the overflow can not happen for this function. Based on these, a new filled function method is proposed, and it is numerically stable to the initial point and the parameter variable. The computer simulations indicate that the proposed filled function method is efficient and effective.
Fractional Quantum Hall States in a Ge Quantum Well.
Mironov, O A; d'Ambrumenil, N; Dobbie, A; Leadley, D R; Suslov, A V; Green, E
2016-04-29
Measurements of the Hall and dissipative conductivity of a strained Ge quantum well on a SiGe/(001)Si substrate in the quantum Hall regime are reported. We analyze the results in terms of thermally activated quantum tunneling of carriers from one internal edge state to another across saddle points in the long-range impurity potential. This shows that the gaps for different filling fractions closely follow the dependence predicted by theory. We also find that the estimates of the separation of the edge states at the saddle are in line with the expectations of an electrostatic model in the lowest spin-polarized Landau level (LL), but not in the spin-reversed LL where the density of quasiparticle states is not high enough to accommodate the carriers required.
Edelman, Mark
2015-07-01
In this paper, we consider a simple general form of a deterministic system with power-law memory whose state can be described by one variable and evolution by a generating function. A new value of the system's variable is a total (a convolution) of the generating functions of all previous values of the variable with weights, which are powers of the time passed. In discrete cases, these systems can be described by difference equations in which a fractional difference on the left hand side is equal to a total (also a convolution) of the generating functions of all previous values of the system's variable with the fractional Eulerian number weights on the right hand side. In the continuous limit, the considered systems can be described by the Grünvald-Letnikov fractional differential equations, which are equivalent to the Volterra integral equations of the second kind. New properties of the fractional Eulerian numbers and possible applications of the results are discussed.
Afterimage watercolors: an exploration of contour-based afterimage filling-in.
Hazenberg, Simon J; van Lier, Rob
2013-01-01
We investigated filling-in of colored afterimages and compared them with filling-in of "real" colors in the watercolor illusion. We used shapes comprising two thin adjacent undulating outlines of which the inner or the outer outline was chromatic, while the other was achromatic. The outlines could be presented simultaneously, inducing the original watercolor effect, or in an alternating fashion, inducing colored afterimages of the chromatic outlines. In Experiment 1, using only alternating outlines, these afterimages triggered filling-in, revealing an "afterimage watercolor" effect. Depending on whether the inner or the outer outline was chromatic, filling-in of a complementary or a similarly colored afterimage was perceived. In Experiment 2, simultaneous and alternating presentations were compared. Additionally, gray and black achromatic contours were tested, having an increased luminance contrast with the background for the black contours. Compared to "real" color filling-in, afterimage filling-in was more easily affected by different luminance settings. More in particular, afterimage filling-in was diminished when high-contrast contours were used. In the discussion we use additional demonstrations in which we further explore the "watercolor afterimage." All in all, comparisons between both types of illusions show similarities and differences with regard to color filling-in. Caution, however, is warranted in attributing these effects to different underlying processing differences.
Fractional Hopfield Neural Networks: Fractional Dynamic Associative Recurrent Neural Networks.
Pu, Yi-Fei; Yi, Zhang; Zhou, Ji-Liu
2017-10-01
This paper mainly discusses a novel conceptual framework: fractional Hopfield neural networks (FHNN). As is commonly known, fractional calculus has been incorporated into artificial neural networks, mainly because of its long-term memory and nonlocality. Some researchers have made interesting attempts at fractional neural networks and gained competitive advantages over integer-order neural networks. Therefore, it is naturally makes one ponder how to generalize the first-order Hopfield neural networks to the fractional-order ones, and how to implement FHNN by means of fractional calculus. We propose to introduce a novel mathematical method: fractional calculus to implement FHNN. First, we implement fractor in the form of an analog circuit. Second, we implement FHNN by utilizing fractor and the fractional steepest descent approach, construct its Lyapunov function, and further analyze its attractors. Third, we perform experiments to analyze the stability and convergence of FHNN, and further discuss its applications to the defense against chip cloning attacks for anticounterfeiting. The main contribution of our work is to propose FHNN in the form of an analog circuit by utilizing a fractor and the fractional steepest descent approach, construct its Lyapunov function, prove its Lyapunov stability, analyze its attractors, and apply FHNN to the defense against chip cloning attacks for anticounterfeiting. A significant advantage of FHNN is that its attractors essentially relate to the neuron's fractional order. FHNN possesses the fractional-order-stability and fractional-order-sensitivity characteristics.
Sorption of Np (Ⅴ) on Beishan granite fracture filling materials
International Nuclear Information System (INIS)
Jiang Tao; Wang Bo; Bao Liangjin; Zhou Duo; Long Haoqi; Song Zhixin; Chen Xi
2012-01-01
The sorption behaviors of Np (Ⅴ) on the granite fracture filling materials were studied by batch experiments under anaerobic in Beishan groundwater. The impact of pH of groundwater, CO 3 2- , humic acid and different components of granite fracture filling materials on sorption of Np (Ⅴ) was investigated. The results show that the granite fracture filling materials have strong capacity of Np (Ⅴ) adsorption. The value of K d , for Np (Ⅴ) sorption on the granite fracture filling materials is 843 mL/g. With the increase of pH, the value of K d increases at first and then decreases. K d of Np sorption on granite fracture filling materials in the presence of CO 3 2- and humic acid decreases. The chlorite and feldspar are major contributors to the sorption of Np (Ⅴ) on Beishan granite fracture filling materials. (authors)
Chemical and nutritional characteristics of high-fibre rye milling fractions.
Kołodziejczyk, Piotr; Makowska, Agnieszka; Pospieszna, Barbara; Michniewicz, Jan; Paschke, Hanna
2018-01-01
Many studies have demonstrated the potential health benefits of consuming more high-fibre cereal-based food products. Therefore, there is a need to discover new ways to improve the overall nutritional balance of refined cereal products and focus on increasing their dietary fibre content, at the expense of readily digestible carbohydrates. Lab-scale milling and sieving of whole rye grain was used to obtain two fractions rich in dietary fibre. The fractions were analysed and compared, in terms of microstructure, chemical com- position and nutritional quality. The two fractions significantly obtained differed in their particle size and contents of minerals, available saccharides, and nutritional fractions of starch and dietary fibre and its major components. The total dietary fibre concentrations in the coarse and fine fractions were 50.0 and 36.0 g/100 g, respectively, i.e. three and 2.2 times higher than that of wholegrain rye flour. Both fractions also differed in their relative proportions of major fibre components. In the fine fraction, the levels of soluble fibre, as well as soluble arabinoxylans and fructans, were significantly higher than those in the coarse fraction. It was shown that the application of a simple dry-fractionation method to wholemeal rye flour allows the preparation of two rye products which can serve as concentrated sources of dietary fibre low in available saccharides.
Biocompatibility of root-end filling materials: recent update
Directory of Open Access Journals (Sweden)
Payal Saxena
2013-08-01
Full Text Available The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.
International Nuclear Information System (INIS)
Ferrari, R.; I.N.F.N., Trento
1994-01-01
The formalism introduced in a previous paper is used for discussing the Coulomb interaction of many electrons moving in two space-dimensions in the presence of a strong magnetic field. The matrix element of the coulomb interaction is evaluated in the new basis, whose states are invariant under discrete translations. This paper is devoted to the case of low filling factor, thus the authors limit themselves to the lowest Landau level and to spins all oriented along the magnetic field. For the case of filling factor ν f = 1/u they give an Ansatz on the state of many electrons which provides a good approximated solution of the Hartree-Fock equation. For general filling factor ν f = u'/u a trial state is given which converges very rapidly to a solution of the self-consistent equation. They generalize the Hartree-Fock equation by considering some correlation: all quantum states are allowed for the u' electrons with the same translation quantum numbers. Numerical results are given for the mean energy and the energy bands, for some values of the filling factor (ν f = 1/2, 1/3, 2/3, 1/4, 3/4, 1/5, 2/5, 3/5, 4/5). The results agree numerically with the Charge Density Wave approach. The boundary conditions are shown to be very important: only large systems (degeneracy of Landau level over 200) are not affected by the boundaries. Therefore results obtained on small scale systems are somewhat unreliable. The relevance of the results for the Fractional Quantum Hall Effect is briefly discussed
International Nuclear Information System (INIS)
Mathonnet, Jean-Eric
2016-01-01
In the framework of the ASTRID project, the nuclear fuel production process by powder metallurgy, for Fast Neutron Reactors, is revisited in order to be simplified. In particular, we seek to remove the mechanical granulation step of the powder which gives a good flow behavior during the filling of press molds. The aim is to reach a spontaneous and quick powder flow through a hole in which the powder does not flow without external energy. Furthermore, the powder alternates between flow phases during the filling of press molds, and non-flow phases during the compaction and ejection of the pellet. We hence apply horizontal vibrations to ensure the flow of the powder through the press mold. The vibrations help the powder to flow and increase the production rates. However, they have the disadvantage to compact the powder and delay the future flows, during the non-flow phases. The art of filling the press mold assisted by vibrations is to master/control the ambivalent nature of the vibrations. The remarkable packing fraction evolution of actinides powders, during the non-flow phases, allows us to define a simple 1D stochastic model to understand the compaction kinetics. The comparison of the stochastic model with the empirical compaction laws found in the literature helps us to identify the physical meaning of fitting parameters proposed by the empirical models. Furthermore, we have also proposed a new compaction law with two-stretched exponentials. This new law not only reflects the compaction kinetics of actinides powders, but also of all the compaction data we found in the literature. (author) [fr
The course of protein synthesis during grain filling in normal and high lysine barley
International Nuclear Information System (INIS)
Giese, H.; Andersen, B.
1984-01-01
A study of the course of protein synthesis during grain filling in Bomi and the high lysine barleys Hily 82/3 and Risoe 56 showed that the four salt-soluble proteins, protein Z, β-amylase and the chymotrypsin inhibitors CI-1 and CI-2, are synthesized in greater amounts earlier in the high lysine lines than in Bomi. On the other hand, the hordeins are synthesized in greater amounts earlier during grain filling in Bomi than in Hily 82/3 and Risoe 56. There is no indication of a significant reduction of total protein synthesis in the high lysine lines compared with the standard lines Bomi and Pirrka. Hily 82/3 and Risoe 56 are very similar in protein composition in that they have a lower hordein content and higher levels, particularly of β-amylase and the chymotrypsin inhibitors, than Bomi. (author)
Concrete Cracking Prediction Including the Filling Proportion of Strand Corrosion Products
Wang, Lei; Dai, Lizhao; Zhang, Xuhui; Zhang, Jianren
2016-01-01
The filling of strand corrosion products during concrete crack propagation is investigated experimentally in the present paper. The effects of stirrups on the filling of corrosion products and concrete cracking are clarified. A prediction model of crack width is developed incorporating the filling proportion of corrosion products and the twisting shape of the strand. Experimental data on cracking angle, crack width, and corrosion loss obtained from accelerated corrosion tests of concrete beams are presented. The proposed model is verified by experimental data. Results show that the filling extent of corrosion products varies with crack propagation. The rust filling extent increases with the propagating crack until a critical width. Beyond the critical width, the rust-filling extent remains stable. Using stirrups can decrease the critical crack width. Stirrups can restrict crack propagation and reduce the rust filling. The tangent of the cracking angle increases with increasing corrosion loss. The prediction of corrosion-induced crack is sensitive to the rust-filling extent. PMID:28772367
Factors affecting marginal integrity of class II bulk-fill composite resin restorations
Savadi Oskoee, Siavash; Bahari, Mahmoud; Jafari Navimipour, Elmira; Ajami, Amir Ahmad; Ghiasvand, Negar; Savadi Oskoee, Ayda
2017-01-01
Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, one on the mesial aspect 1 mm coronal to the CEJ and one on the distal aspect 1 mm apical to the CEJ. The teeth were divided into 4 groups: A: The cavities were restored using the bulk-fill technique with Filtek P90 composite resin and its adhesive system and light-cured with quartz tungsten halogen (QTH) light-curing unit. B: The cavities were restored similar to that in group A but light-cured with an LED light-curing unit. C: The cavities were restored using the bulk-fill technique with X-tra Fil composite resin and Clearfil SE Bond adhesive system and light-cured with a QTH curing unit. D: The cavities were restored similar to that in group C but light-cured with an LED light-curing unit. The gaps were examined under a stereomicroscope at ×60. Data were analyzed with General Linear Model test. In cases of statistical significance (Pcomposite resin type and margin location (Pcomposite resin type were not significant; however, the cumulative effect of composite rein type*gingival margin was significant (P=0.04) Conclusion. X-tra Fil composite exhibited smaller gaps compared with Filtek P90 composite with both light-curing units. Both composite resins exhibited smaller gaps at enamel margins. PMID:28748051
Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications
International Nuclear Information System (INIS)
Alan E. Bland
2003-01-01
Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill(trademark). The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable
Market Assessment and Demonstration of Lignite FBC Ash Flowable Fill Applications
Energy Technology Data Exchange (ETDEWEB)
Alan E. Bland
2003-09-30
Montana-Dakota Utilities (MDU) and Western Research Institute (WRI) have been developing flowable fill materials formulated using ash from the Montana-Dakota Utilities R. M. Heskett Station in Mandan, North Dakota. MDU and WRI have partnered with the U.S. Department of Energy (DOE) and the North Dakota Industrial Commission (NDIC) to further the development of these materials for lignite-fired fluidized-bed combustion (FBC) facilities. The MDU controlled density fill (CDF) appears to be a viable engineering material and environmentally safe. WRI is pursuing the commercialization of the technology under the trademark Ready-Fill{trademark}. The project objectives were to: (1) assess the market in the Bismarck-Mandan area; (2) evaluate the geotechnical properties and environmental compatibility; and (3) construct and monitor demonstrations of the various grades of flowable fill products in full-scale demonstrations. The scope of initial phase of work entailed the following: Task I--Assess Market for MDU Flowable Fill Products; Task II--Assess Geotechnical and Environmental Properties of MDU Flowable Fill Products; and Task III--Demonstrate and Monitor MDU Flowable Fill Products in Field-Scale Demonstrations. The results of these testing and demonstration activities proved the following: (1) The market assessment indicated that a market exists in the Bismarck-Mandan area for structural construction applications, such as sub-bases for residential and commercial businesses, and excavatable fill applications, such as gas line and utility trench filling. (2) The cost of the MDU flowable fill product must be lower than the current $35-$45/cubic yard price if it is to become a common construction material. Formulations using MDU ash and lower-cost sand alternatives offer that opportunity. An estimated market of 10,000 cubic yards of MDU flowable fill products could be realized if prices could be made competitive. (3) The geotechnical properties of the MDU ash-based flowable
Misonidazole in fractionated radiotherapy: are many small fractions best
International Nuclear Information System (INIS)
Denekamp, J.; McNally, N.J.; Fowler, J.F.; Joiner, M.C.
1980-01-01
The largest sensitizing effect is always demonstrated with six fractions, each given with 2 g/m 2 of misonidazole. In the absence of reoxygenation a sensitizer enhancement ratio of 1.7 is predicted, but this falls to 1.1-1.2 if extensive reoxygenation occurs. Less sensitization is observed with 30 fractions, each with 0.4 g/m 2 of drug. However, for clinical use, the important question is which treatment kills the maximum number of tumour cells. Many of the simulations predict a marked disadvantage of reducing the fraction number for X rays alone. The circumstances in which this disadvantage is offset by the large Sensitizer enhancement ratio values with a six-fraction schedule are few. The model calculations suggest that many small fractions, each with a low drug dose, are safest unless the clinician has some prior knowledge that a change in fraction number is not disadvantageous. (author)
Reemergence of apoptotic cells between fractionated doses in irradiated murine tumors
International Nuclear Information System (INIS)
Meyn, R.E.; Hunter, N.R.; Milas, L.
1994-01-01
The purpose of this investigation was to follow up our previous studies on the development of apoptosis in irradiated murine tumors by testing whether an apoptotic subpopulation of cells reemerges between fractionated exposures. Mice bearing a murine ovarian carcinoma, OCa-I, were treated in vivo with two fractionation protocols: two doses of 12.5 Gy separated by various times out to 5 days and multiple daily fractions of 2.5 Gy. Animals were killed 4 h after the last dose in each protocol, and the percent apoptosis was scored from stained histological sections made from the irradiated tumors according to the specific features characteristic of this mode of cell death. The 12.5+12.5 Gy protocol yielded a net total percent apoptosis of about 45% when the two doses were separated by 5 days (total dose = 25 Gy), whereas the 2.5 Gy per day protocol yielded about 50% net apoptotic cells when given for 5 days (total dose = 12.5 Gy). These values are to be compared to the value of 36% apoptotic cells that is yielded by large single doses (> 25 Gy). Thus, these results indicate that an apoptotic subpopulation of cells reemerged between the fractions in both protocols, but the kinetics appeared to be delayed in the 12.5+12.5 Gy vs. the multiple 2.5 Gy protocol. This reemergence of cells with the propensity for radiation-induced apoptosis between fractionated exposures is consistent with a role for this mode of cell death in the response of tumors to radiotherapy and may represent the priming of a new subpopulation of tumor cells for apoptosis as part of normal tumor homeostasis to counterbalance cell division. 25 refs., 3 figs., 1 tab
Fractional dynamic calculus and fractional dynamic equations on time scales
Georgiev, Svetlin G
2018-01-01
Pedagogically organized, this monograph introduces fractional calculus and fractional dynamic equations on time scales in relation to mathematical physics applications and problems. Beginning with the definitions of forward and backward jump operators, the book builds from Stefan Hilger’s basic theories on time scales and examines recent developments within the field of fractional calculus and fractional equations. Useful tools are provided for solving differential and integral equations as well as various problems involving special functions of mathematical physics and their extensions and generalizations in one and more variables. Much discussion is devoted to Riemann-Liouville fractional dynamic equations and Caputo fractional dynamic equations. Intended for use in the field and designed for students without an extensive mathematical background, this book is suitable for graduate courses and researchers looking for an introduction to fractional dynamic calculus and equations on time scales. .
Papaemmanouil, Christina; Tsiafoulis, Constantinos G; Alivertis, Dimitrios; Tzamaloukas, Ouranios; Miltiadou, Despoina; Tzakos, Andreas G; Gerothanassis, Ioannis P
2015-06-10
We report a rapid, direct, and unequivocal spin-chromatographic separation and identification of minor components in the lipid fraction of milk and common dairy products with the use of selective one-dimensional (1D) total correlation spectroscopy (TOCSY) nuclear magnetic resonance (NMR) experiments. The method allows for the complete backbone spin-coupling network to be elucidated even in strongly overlapped regions and in the presence of major components from 4 × 10(2) to 3 × 10(3) stronger NMR signal intensities. The proposed spin-chromatography method does not require any derivatization steps for the lipid fraction, is selective with excellent resolution, is sensitive with quantitation capability, and compares favorably to two-dimensional (2D) TOCSY and gas chromatography-mass spectrometry (GC-MS) methods of analysis. The results of the present study demonstrated that the 1D TOCSY NMR spin-chromatography method can become a procedure of primary interest in food analysis and generally in complex mixture analysis.
Directory of Open Access Journals (Sweden)
Alexis Vidal Novoa
2011-02-01
Full Text Available Hydrophilic and lipophilic fractions, obtained from the marine algae Halimeda incrassata (J.Ellis J.V.Lamouroux, Halimedaceae, were studied by using the ²-carotene-linoleate assay system. In case of hydrophilic fractions, the total phenolic compounds were quantified and two of their components were identified as salicylic and ferulic acids. From the lipophilic fraction, fatty acid composition was studied. The highest antioxidant activities values were found on the polar fractions containing phenolic acids. The total phenolics content on the hydrophilic fractions was 255 μg of gallic acid equivalents/g of fresh seaweed. To further characterize H. incrassata chemical composition, the total lipid content was quantified (7.4 mg per gram of dried algae as well as the saturated and unsaturated fatty acids ratio (1:1.46. In summary, this paper adds more convincing evidences in support of the antioxidant abilities of the lyophilized aqueous extract of Halimeda incrassata and it also relates this bioactivity, for the first time, with particular phenolic components of the extract. Altogether, these results represent another step towards the use of this natural product as drug candidates.
CHARACTERISTICS OF FLORIDA FILL MATERIALS AND SOILS 1990
The report gives results of laboratory work by the University of Florida in support of the Foundation Fill Data Base project of the Foundation Fill Materials Specifications Task Area of the Florida Radon Research Program (FRRP). Work included determination of radon concentrations...
Modeling ductal carcinoma in situ: a HER2-Notch3 collaboration enables luminal filling.
LENUS (Irish Health Repository)
Pradeep, C-R
2012-02-16
A large fraction of ductal carcinoma in situ (DCIS), a non-invasive precursor lesion of invasive breast cancer, overexpresses the HER2\\/neu oncogene. The ducts of DCIS are abnormally filled with cells that evade apoptosis, but the underlying mechanisms remain incompletely understood. We overexpressed HER2 in mammary epithelial cells and observed growth factor-independent proliferation. When grown in extracellular matrix as three-dimensional spheroids, control cells developed a hollow lumen, but HER2-overexpressing cells populated the lumen by evading apoptosis. We demonstrate that HER2 overexpression in this cellular model of DCIS drives transcriptional upregulation of multiple components of the Notch survival pathway. Importantly, luminal filling required upregulation of a signaling pathway comprising Notch3, its cleaved intracellular domain and the transcriptional regulator HES1, resulting in elevated levels of c-MYC and cyclin D1. In line with HER2-Notch3 collaboration, drugs intercepting either arm reverted the DCIS-like phenotype. In addition, we report upregulation of Notch3 in hyperplastic lesions of HER2 transgenic animals, as well as an association between HER2 levels and expression levels of components of the Notch pathway in tumor specimens of breast cancer patients. Therefore, it is conceivable that the integration of the Notch and HER2 signaling pathways contributes to the pathophysiology of DCIS.
Implication of fractionated dose exposures in therapeutic gain
International Nuclear Information System (INIS)
Kim, Hye-Jin; Lee, Min-Ho; Kim, Eun-Hee
2016-01-01
Radiation therapy pursues killing tumor cells while sparing normal cells from the radiation exposure. Stereotactic radiosurgery (SRS) is a cancer treatment modality that delivers a high dose in a single operation. This high-dose single operation shortens the treatment course, but can increase the risk of normal cell damage. Normal cell damage can be reduced by employing multi-directional exposures for an increasing number of isocenters. In this study, we investigated whether therapeutic benefits would be expected by employing new dose fractionation patterns at a high-dose single operation. The conventional single-dose operation in brain tumor radiosurgery is performed by delivering fractionated uniform doses. According to Figs. 2 and 3, the conventional radiosurgery might have obtained some therapeutic benefit by employing the fractionated uniform-dose exposures instead of a single-dose exposure. We suggest that further therapeutic gain be expected by employing the fractionated radiation exposures in an increasing dose pattern. Until ensuring our suggestion, the significance in gain of cell surviving should be verified for all three dose patterns with both normal and tumor cells. The investigation whether normal and tumor cells show the same responses to the fractionated dose exposures at lower and higher than 15 Gy of total dose is also reserved for future work
Impact of implant size on cement filling in hip resurfacing arthroplasty.
de Haan, Roel; Buls, Nico; Scheerlinck, Thierry
2014-01-01
Larger proportions of cement within femoral resurfacing implants might result in thermal bone necrosis. We postulate that smaller components are filled with proportionally more cement, causing an elevated failure rate. A total of 19 femoral heads were fitted with polymeric replicas of ReCap (Biomet) resurfacing components fixed with low-viscosity cement. Two specimens were used for each even size between 40 and 56 mm and one for size 58 mm. All specimens were imaged with computed tomography, and the cement thickness and bone density were analyzed. The average cement mantle thickness was 2.63 mm and was not correlated with the implant size. However, specimen with low bone density had thicker cement mantles regardless of size. The average filling index was 36.65% and was correlated to both implant size and bone density. Smaller implants and specimens with lower bone density contained proportionally more cement than larger implants. According to a linear regression model, bone density but not implant size influenced cement thickness. However, both implant size and bone density had a significant impact on the filling index. Large proportions of cement within the resurfacing head have the potential to generate thermal bone necrosis and implant failure. When considering hip resurfacing in patients with a small femoral head and/or osteoporotic bone, extra care should be taken to avoid thermal bone necrosis, and alternative cementing techniques or even cementless implants should be considered. This study should help delimiting the indications for hip resurfacing and to choose an optimal cementing technique taking implant size into account.
International Nuclear Information System (INIS)
Fareed, G.; Afza, N.; Mali, A.; Fareed, N.; Lateef, M.; Iqbal, L.; Mughal, U.R
2013-01-01
This study was designed to explore the phytochemical screening, total phenolic contents, radical scavenging potential and urease inhibitory activities in various fractions of the aerial parts of Nepeta praetervisa. Sub-fractions (n-hexane, chloroform, ethyl acetate, n-butanol, and aqueous) were prepared from the crude methanolic extract using partition chromatography. Phytochemical tests were performed and revealed the presence of various classes of secondary metabolites in various sub-fractions (Table-1). Total phenolic contents of all the fractions were determined using Folin-Ciocalteu (FC) reagent and the ethyl acetate sub-fraction was found to possess the highest level of phenolic contents (627.25 mg gallic acid equivalent (GAE)/g) as compared to the other fractions. The radical scavenging activity was determined at various concentrations ranging from 2.5 - 0.15 micro g /10 mu L by 1,1-diphenyl-2-picrylhydrazyl radical (DPPH) method. At the lowest concentration level, the ethyl acetate sub-fraction showed maximum level of antioxidant activity (78%) compared to BHA used as standard. The decreasing order of activity was ethyl acetate>chloroform>aqueous>n-butanol>methanol>n-hexane. On the other hand when all these fractions were screened for urease inhibition activity using indophenols method, the ethyl acetate sub-fraction showed significant urease inhibitory activity (68 %) compared with the standard thiourea at the concentration of 50 mu g /10 mu L. The decreasing order of activity of various sub-fractions was ethyl acetate>chloroform>hexane>aqueous, while n-butanol sub- fraction was inactive. (author)
Fractional gradient and its application to the fractional advection equation
D'Ovidio, M.; Garra, R.
2013-01-01
In this paper we provide a definition of fractional gradient operators, related to directional derivatives. We develop a fractional vector calculus, providing a probabilistic interpretation and mathematical tools to treat multidimensional fractional differential equations. A first application is discussed in relation to the d-dimensional fractional advection-dispersion equation. We also study the connection with multidimensional L\\'evy processes.
Root canal filling using Resilon: a review.
LENUS (Irish Health Repository)
Shanahan, D J
2011-07-01
Root canal treatment is achieved by chemo-mechanical debridement of the root canal system followed by filling. The filling material \\'entombs\\' residual bacteria and acts as a barrier which prevents the entrance of oral microorganisms and reinfection of the root canal system through microleakage. However, filling with contemporary root filling materials such as gutta-percha offers limited long-term resistance to microorganisms; as a result other materials such as Resilon have been investigated as alternatives. The aim of this review was to analyse the literature to consider whether Resilon is a suitable root canal filling material. A MEDLINE and Cochrane library search including various keyword searches identified several papers which investigated or discussed Resilon or RealSeal\\/Epiphany. Analysis of the literature demonstrated that the bulk of the literature is in vitro in nature, based largely on leakage-type studies, and demonstrates a wide variety of methodologies with conflicting findings; as a result meaningful conclusions are difficult. Within the limit of these in vitro studies Resilon appears to perform adequately in comparison to gutta-percha, however, as a result of the questionable merit of such studies, it cannot presently be considered an evidence-based alternative to the current gold standard gutta-percha. It is imperative that before Resilon is considered as a replacement material, a better understanding of the physical properties of the resin sealer and the reality of the adhesive \\'monoblock\\' are elucidated. The literature also demonstrates a paucity of quality long-term clinical outcome studies which will need to be addressed before firm conclusions can be reached.
Repair of skin damage during fractionated irradiation with gamma rays and low-LET carbon ions
International Nuclear Information System (INIS)
Ando, Koichi; Koike, Sachiko; Uzawa, Akiko; Takai, Nobuhiko; Fukawa, Takeshi; Furusawa, Yoshiya; Aoki, Mizuho; Hirayama, Ryoichi
2006-01-01
In clinical use of carbon-ion beams, a deep-seated tumor is irradiated with a Spread-Out Bragg peak (SOBP) with a high-linear energy transfer (LET) feature, whereas surface skin is irradiated with an entrance plateau, the LET of which is lower than that of the peak. The repair kinetics of murine skin damage caused by an entrance plateau of carbon ions was compared with that caused by photons using a scheme of daily fractionated doses followed by a top-up dose. Right hind legs received local irradiations with either 20 keV/μm carbon ions or γ rays. The skin reaction of the irradiated legs was scored every other day up to Day 35 using a scoring scale that consisted of 10 steps, ranging from 0.5 to 5.0. An isoeffect dose to produce a skin reaction score of 3.0 was used to obtain a total dose and a top-up dose for each fractionation. Dependence on a preceding dose and on the time interval of a top-up dose was examined using γ rays. For fractionated γ rays, the total dose linearly increased while the top-up dose linearly decreased with an increase in the number of fractions. The magnitude of damage repair depended on the size of dose per fraction, and was larger for 5.2 Gy than 12.5 Gy. The total dose of carbon ions with 5.2 Gy per fraction did not change till 2 fractions, but abruptly increased at the 3rd fraction. Factors such as rapid repopulation, induced repair and cell cycle synchronization are possible explanations for the abrupt increase. As an abrupt increase/decrease of normal tissue damage could be caused by changing the number of fractions in carbon-ion radiotherapy, we conclude that, unlike photon therapy, skin damage should be carefully studied when the number of fractions is changed in new clinical trials. (author)
Potential of scrap tire rubber as lightweight aggregate in flowable fill.
Pierce, C E; Blackwell, M C
2003-01-01
Flowable fill is a self-leveling and self-compacting material that is rapidly gaining acceptance and application in construction, particularly in transportation and utility earthworks. When mixed with concrete sand, standard flowable fill produces a mass density ranging from 1.8 to 2.3 g/cm(3) (115-145 pcf). Scrap tires can be granulated to produce crumb rubber, which has a granular texture and ranges in size from very fine powder to coarse sand-sized particles. Due to its low specific gravity, crumb rubber can be considered a lightweight aggregate. This paper describes an experimental study on replacing sand with crumb rubber in flowable fill to produce a lightweight material. To assess the technical feasibility of using crumb rubber, the fluid- and hardened-state properties of nine flowable fill mixtures were measured. Mixture proportions were varied to investigate the effects of water-to-cement ratio and crumb rubber content on fill properties. Experimental results indicate that crumb rubber can be successfully used to produce a lightweight flowable fill (1.2-1.6 g/cm(3) [73-98 pcf]) with excavatable 28-day compressive strengths ranging from 269 to 1194 kPa (39-173 psi). Using a lightweight fill reduces the applied stress on underlying soils, thereby reducing the potential for bearing capacity failure and minimizing soil settlement. Based on these results, a crumb rubber-based flowable fill can be used in a substantial number of construction applications, such as bridge abutment fills, trench fills, and foundation support fills.
International Nuclear Information System (INIS)
Yousri, R.M.; Roushdy, H.; Gawish, M.A.M.
1991-01-01
The effect of sublethal and lethal total body gamma irradiation on some serum lipid fractions in male rats was investigated. The protective efficacy of estradiol and/or α-tocopherol was also studied. The results of this study demonstrate that the lethally irradiated rats showed significant alteration in serum triglycerides, cholesterol, total lipids and phospholipids level. Estradiol exerted a benefical effect on lipid fractions after one and two days post lethal α-irradiation (8 Gy). No consistent radioprotective effect of tocopherol could be detected on the levels of serum lipid fractions. This finding was also observed when both radioprotectors were used. (orig.) [de
[Experimental study of percutaneous vertebroplasty with a novel bone void filling container system].
Wang, Tai-Ping; Zhang, Kui-bo; Zheng, Zhao-min; Liu, Hui; Yu, Bin-sheng
2011-04-19
To investigate vertebral augmentation with a novel reticulate bone filling container system by polymethyl methacrylate (PMMA) injection in cadaveric simulated vertebral compressive fracture and explore the effect of reticulate bone filling container on cement distribution controlling within vertebral body and the restoration of biomechanical properties after augmentation. A total of 28 freshly frozen human vertebrae specimens were randomly divided into 4 groups. After the measurements of bone mineral density (BMD) and vertebral height, each vertebra received an axle load by a MTS (material testing system) machine to test the initial strength and stiffness. Subsequently a simultaneous compressive fracture model was created to measure the stiffness and height of fractured vertebrae. Then the augmentation procedure was performed. Afterward the biomechanical properties and the vertebral height were similarly measured as pre-operatively. The expansion of bone filling container and the distribution of cement within vertebral body were morphologically observed by crossing the specimens in sagittal midline and also integrated with the radiographic results. Stiffness was significantly restored comparing with that of fractured level (P container groups while it was irregular in single-layer groups. After crossing, the double-layer version expanded well in vertebral body and could enwrap most of injected cement. There was only a little leakage near the vessel layer. But the single-layer version had a poor expansion and a large amount of cement leakage. This novel reticulate bone void filling container system with different layers may restore both the biomechanical properties and the height of fractured vertebrae. But, with the benefit of reducing cement leakage, a double-layer design can enwrap most of injected PMMA and has a brighter prospect of clinical application.
International Nuclear Information System (INIS)
Yano, Toshikazu
1983-11-01
In order to clarify the transient mass flow rate under the instantaneous pipe rupture condition, it is necessary to use a highly sensitive void meter. Therefore, a high-response gamma-ray densitometer was developed for the measurement of void fraction variation caused by flashing vaporization of the high-pressure and -temperature water under the instantaneous pipe rupture accident. The measurement of void fraction was performed in the pipe rupture test under the BWR LOCA condition with a 6-inch diameter pipe. Initial conditions of the water were 6.86 MPa in pressure and the saturation temperature. To prove the reliability and accuracy, a calibration test by falling acrylic void simulators and an air injection test into cold water filled in the pipe were also conducted. The following results are obtained in the pipe rupture test. (1) The cone slit method is very useful to increase the measuring accuracy. (2) It is clearly observed that the apparent increase of void fraction occurs after the rarefaction wave passes. (3) The first maximum of void fraction occurs with some delay time after break. The following minimum void fraction concurs with the maximum pressure in the pressure recovering phenomena and with the maximum blowdown thrust force. (author)
Energy Technology Data Exchange (ETDEWEB)
Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)
2011-08-15
To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.
International Nuclear Information System (INIS)
Waer, M.; Vanrenterghem, Y.; Ang, K.K.; van der Schueren, E.; Michielsen, P.; Vandeputte, M.
1984-01-01
Beginning in November 1981, eight patients with end stage diabetic nephropathy underwent renal cadaveric transplantation after TLI. Transplantation was done between 2 to 11 days after the end of a fractionated TLI to a total dose of 20 to 30 Gy. During the same observation period, 60 nondiabetic patients with end stage renal disease of different origin also received a cadaveric kidney graft, with a conventional regimen of immunosuppression that consists of anti-lymphocyte-globulin, tapering high doses of prednisone, and azathioprine. Phytohemagglutinin (PHA)-, concanavalin A (con A)-, and pokeweed mitogen (PWM)-induced blastogenesis, as well as the mixed lymphocyte reaction (MLR) and the cell-mediated lympholysis (CML) decreased progressively during the first months after conventional immunosuppression to 50% of the pretransplantation level, and remained there for the first year after transplantation. These tests were much more impaired after TLI and again no recovery occurred during the first year. In the clinic, the more profound immunosuppression in TLI patients was more frequently associated with viral infections (cytomegalovirus and herpes zoster). The incidence of rejections, however, was somewhat less frequent in the TLI-treated group and occurred significantly later. After TLI, the mean cumulative dose of steroids needed for kidney transplantation during the first year after transplantation could be substantially reduced
Directory of Open Access Journals (Sweden)
V. F. Melo
2003-10-01
arenito da Formação Uberaba, migmatito/micaxisto do Grupo Araxá e basalto da Formação Serra Geral.Few studies relate the K reserve in soils developed in a humid tropic climate with the minerals found in the clay fraction. Nineteen soils were collected for this purpose in the Triângulo Mineiro region, Minas Gerais State, Brazil, developed from different parent materials and different weathering degrees. Due to the greater occurrence, a larger number of samples of the Bauru Group was collected, comprising all the geological formations found in the region. The total K content in soil and the sand, silt, and clay fractions were determined after the digestion of the soil samples by HF, HNO3 and H2SO4. To quantify the contribution of each mineral species to the total K content, Na-saturated clay samples were submitted by a sequential and selective mineral extraction procedure, following the order: amorphous Al and Fe oxides; crystalline Fe oxides; kaolinite and gibbsite; mica and other 2:1 minerals and; feldspar and resistant minerals. The clay mineralogy composition reflects the high weathering and leaching degree in soils of the Triângulo Mineiro, with low contents of amorphous minerals, a predominant proportion of kaolinite and the presence of other secondary resistant minerals. In spite of this mineral composition, the clay fraction presented the highest total K content, mainly in the most weathered soils. Due to the high proportion of kaolinite in the clay fraction, this mineral was an important source of non-exchangeable K forms. On the other hand, the contribution of amorphous Fe and Al oxides and crystalline Fe oxides to the total K content of the clay fraction was negligible. In general, easily weathered primary minerals (mica and feldspar contributed largely to the total K of the clay fraction, principally to the youngest soils developed from the Uberaba (sandstone and Serra Geral (basalt Formations, and the Araxá Group (migmatite/micaschist.
Fissure fillings from Finnsjoen and Studsvik Sweden
International Nuclear Information System (INIS)
Tullborg, E.-L.; Larsson, S.Aa.
1982-12-01
Samples were taken from cores and collected at different levels. The bedrock at Finnsjoen is a Svecokarelian granite-granodiorite, the most frequent mineral in the fissures being calcite. The water from boreholes have a mean S 18 O value of -12 per thousand and saturated by calcite. Isotopically three different groups of calcite have been distinguished. Ages of 29+-13x10 3 years to 79+-25x10 3 years were estimated. Two generations of quartz were recognized the minerals prehnite and lanmontite were found Most fissure filling materials have cation exchange capacities. The bedrock at Studsvik is a Svecokarelian gneiss of sedimentary type which is migmatized with calcite and chlorite as fissure filling minerals. Most fissure fillings are thin and simple Claby minerals of smectite type are also frequent. (G.B.)
Fluid dynamics following flow shut-off in bottle filling
Thete, Sumeet; Appathurai, Santosh; Gao, Haijing; Basaran, Osman
2012-11-01
Bottle filling is ubiquitous in industry. Examples include filling of bottles with shampoos and cleaners, engine oil and pharmaceuticals. In these examples, fluid flows out of a nozzle to fill bottles in an assembly line. Once the required volume of fluid has flowed out of the nozzle, the flow is shut off. However, an evolving fluid thread or string may remain suspended from the nozzle following flow shut-off and persist. This stringing phenomenon can be detrimental to a bottle filling operation because it can adversely affect line speed and filling accuracy by causing uncertainty in fill volume, product loss and undesirable marring of the bottles' exterior surfaces. The dynamics of stringing are studied numerically primarily by using the 1D, slender-jet approximation of the flow equations. A novel feature entails development and use of a new boundary condition downstream of the nozzle exit to expedite the computations. While the emphasis is on stringing of Newtonian fluids and use of 1D approximations, results will also be presented for situations where (a) the fluids are non-Newtonian and (b) the full set of equations are solved without invoking the 1D approximation. Phase diagrams will be presented that identify conditions for which stringing can be problematic.
Chang, Xiaoping; Li, Runzhi; Jing, Ruilian
2014-01-01
Drought, heat and other abiotic stresses during grain filling can result in reductions in grain weight. Conserved water-soluble carbohydrates (WSC) at early grain filling play an important role in partial compensation of reduced carbon supply. A diverse population of 262 historical winter wheat accessions was used in the present study. There were significant correlations between 1000-grain weight (TGW) and four types of WSC, viz. (1) total WSC at the mid-grain filling stage (14 days after flowering) produced by leaves and non-leaf organs; (2) WSC contributed by current leaf assimilation during the mid-grain filling; (3) WSC in non-leaf organs at the mid-grain filling, excluding the current leaf assimilation; and (4) WSC used for respiration and remobilization during the mid-grain filling. Association and favorable allele analyses of 209 genome-wide SSR markers and the four types of WSC were conducted using a mixed linear model. Seven novel favorable WSC alleles exhibited positive individual contributions to TGW, which were verified under 16 environments. Dosage effects of pyramided favorable WSC alleles and significantly linear correlations between the number of favorable WSC alleles and TGW were observed. Our results suggested that pyramiding more favorable WSC alleles was effective for improving both WSC and grain weight in future wheat breeding programs. PMID:25036550
The Cryogenic Studying and Filling Facilities for the Laser Megajoule Targets
Energy Technology Data Exchange (ETDEWEB)
Bachelet, F.; Vincent-Viry, O.; Collier, R.; Fleury, E.; Jeannot, L.; Legaie, O.; Pascal, G. [CEA Valduc, DAM, 21 - Is-sur-Tille (France); Perin, J. P.; Viargues, F. [CEA Grenoble, DSM INAC SBT, 38 (France)
2009-04-15
As part of the French Inertial Confinement Fusion program, Commissariat a l'Energie Atomique has developed cryogenic target assemblies (CTAs) for the Laser Megajoule (LMJ) and a program in two stages for the permeation filling of these CTAs: (a) the permeation filling studies with the Study Filling Station cryostats and (b) the design and manufacturing of the whole operational chain of CTA filling facilities. This paper deals with the description of both the cryogenic studying and the filling facilities for the LMJ targets. (authors)
Twice-a-day fractionated radiotherapy for head and neck cancer
Energy Technology Data Exchange (ETDEWEB)
Kita, Midori [Tokyo Metropolitan Hospital of Fuchu (Japan)
1996-12-01
To improve the local control rate in radiotherapy for hand and neck cancer, several prospected twice-a-day fractionated radiotherapy (TDRF) were conducted in Tokyo Women`s Medical College. T2 glottic cancer was irradiated with 1.5 Gy/fraction, 2 fraction/day to a total dose of 72 Gy. Five cumulative local control rate was 88.2%. Locally advanced head and neck cancer was treated with TDFR and systemic chemotherapy. Response rate was 100%. Palliative radiotherapy with TDFR was done to relive from the pain and other symptoms for advanced and recurrent cases. Nine cases of 11 were relieved from the symptoms. These results was suggested the TDFR was useful to improve the local control rate. (author)
Twice-a-day fractionated radiotherapy for head and neck cancer
International Nuclear Information System (INIS)
Kita, Midori
1996-01-01
To improve the local control rate in radiotherapy for hand and neck cancer, several prospected twice-a-day fractionated radiotherapy (TDRF) were conducted in Tokyo Women's Medical College. T2 glottic cancer was irradiated with 1.5 Gy/fraction, 2 fraction/day to a total dose of 72 Gy. Five cumulative local control rate was 88.2%. Locally advanced head and neck cancer was treated with TDFR and systemic chemotherapy. Response rate was 100%. Palliative radiotherapy with TDFR was done to relive from the pain and other symptoms for advanced and recurrent cases. Nine cases of 11 were relieved from the symptoms. These results was suggested the TDFR was useful to improve the local control rate. (author)
Altered fractionated radiotherapy has a survival benefit for head and neck cancers. Is it true?
International Nuclear Information System (INIS)
Hatano, Kazuo; Sakai, Mitsuhiro; Araki, Hitoshi; Doi, Katsuyuki; Asano, Takanori; Fujikawa, Akira
2007-01-01
There was a significant survival benefit with altered fractionated radiotherapy, corresponding to an absolute benefit of 3.4% at 5 years. The benefit was significantly higher with hyperfractionated radiotherapy (8% at 5 years) than with accelerated radiotherapy (2% with accelerated fractionation without total dose reduction and 1.7% with total dose reduction at 5 years). The effect was greater for the primary tumor than for nodal disease. The effect was also more pronounced in younger patients and in those with good performance status. Hyperfractionation seemed to yield a more consistent advantage for survival than accelerated fractionated radiotherapy. However, accelerated radiotherapy might be associated with higher non-cancer related death. We have to evaluate whether the benefit of hyperfractionated radiotherapy versus standard radiotherapy persists when combined with concomitant chemotherapy and the benefit of intensity-modulated radiation therapy (IMRT) compared with altered fractionation. (author)
Space-filling polyhedral sorbents
Energy Technology Data Exchange (ETDEWEB)
Haaland, Peter
2016-06-21
Solid sorbents, systems, and methods for pumping, storage, and purification of gases are disclosed. They derive from the dynamics of porous and free convection for specific gas/sorbent combinations and use space filling polyhedral microliths with facial aplanarities to produce sorbent arrays with interpenetrating interstitial manifolds of voids.
Beam Attenuators and the Risk of Unrecognized Large-Fraction Irradiation of Critical Tissues
International Nuclear Information System (INIS)
Luka, S.; Marks, J.E.
2015-01-01
The use of radiation beam attenuators led to radiation injury of the spinal cord in one patient and of the peripheral nerve in another due to unsuspected large-fraction irradiation. The anatomic distribution of radiation dose was reconstructed in the sagittal plane for the patient who developed radiation myelopathy and in the axial plane for the patient who developed peripheral neuropathy. The actual dose delivered to the injured structure in each patient was taken from the dose distribution and recorded along with the time, number of fractions, and dose per fraction. The patient who developed radiation myelopathy received a total of 46.5 Gy in twenty-three 2.1 Gy fractions in 31 days to the upper cervical spinal cord where the thickness of the neck was less than the central axis thickness due to cervical lordosis and absence of a posterior compensating filter. The patient who developed peripheral neuropathy received 55 Gy in twenty-five 2.2 Gy fractions in 50 days to the femoral nerve using bolus over the groins and an anterior one-half value layer Cerrobend pelvic block to bias the dose anteriorly. Compensating filters and other beam attenuators should be used with caution because they may result in unsuspected large-fraction irradiation and total doses of radiation that exceed the tolerance of critical structures.
Beam Attenuators and the Risk of Unrecognized Large-Fraction Irradiation of Critical Tissues
Energy Technology Data Exchange (ETDEWEB)
Luka, S.; Marks, J.E.
2015-01-15
The use of radiation beam attenuators led to radiation injury of the spinal cord in one patient and of the peripheral nerve in another due to unsuspected large-fraction irradiation. The anatomic distribution of radiation dose was reconstructed in the sagittal plane for the patient who developed radiation myelopathy and in the axial plane for the patient who developed peripheral neuropathy. The actual dose delivered to the injured structure in each patient was taken from the dose distribution and recorded along with the time, number of fractions, and dose per fraction. The patient who developed radiation myelopathy received a total of 46.5 Gy in twenty-three 2.1 Gy fractions in 31 days to the upper cervical spinal cord where the thickness of the neck was less than the central axis thickness due to cervical lordosis and absence of a posterior compensating filter. The patient who developed peripheral neuropathy received 55 Gy in twenty-five 2.2 Gy fractions in 50 days to the femoral nerve using bolus over the groins and an anterior one-half value layer Cerrobend pelvic block to bias the dose anteriorly. Compensating filters and other beam attenuators should be used with caution because they may result in unsuspected large-fraction irradiation and total doses of radiation that exceed the tolerance of critical structures.
Calculation of piping loads due to filling procedures
International Nuclear Information System (INIS)
Swidersky, Harald; Thiele, Thomas
2012-01-01
Filling procedures in piping systems are usually not load cases that are studied by fluid dynamic and structure dynamic analyses with respect to the integrity of pipes and supports. Although, their frequency is higher than that of postulated accidental transients, therefore they have to be considered for fatigue analyses. The piping and support loads due to filling procedures are caused by the density differences if the transported fluids, for instance in flows with the transport of gas bubbles. The impact duration of the momentum forces is defined by the flow velocity and the length of discontinuities in the piping segments. Filling procedures end very often with a shock pressure, caused by the impact and decelerating of the fluid front at smaller cross sections. The suitability of the thermally hydraulics program RELAP/MOD3.3 for the calculation of realistic loads from filling procedures was studied, the results compared with experimental data. It is shown that dependent on the discretization level the loads are partial significantly underestimated.
Structural, electronic, and thermal properties of indium-filled InxIr4Sb12 skutterudites
Wallace, M. K.; Li, Jun; Subramanian, M. A.
2018-06-01
The "phonon-glass/electron-crystal" approach has been implemented through incorporation of "rattlers" into skutterudite void sites to increase phonon scattering and thus increase the thermoelectric efficiency. Indium filled IrSb3 skutterudites are reported for the first time. Polycrystalline samples of InxIr4Sb12 (0 ≤ x ≤ 0.2) were prepared by solid-state reaction under a gas mixture of 5% H2 and 95% Ar. The solubility limit of InxIr4Sb12 was found to be close to 0.18. Synchrotron X-ray diffraction refinements reveal all InxIr4Sb12 phases crystallized in body-centered cubic structure (space group : Im 3 bar) with ∼8% antimony site vacancy and with indium partially occupying the 16f site. Unlike known rattler filled skutterudites, under synthetic conditions employed, indium filling in IrSb3 significantly increases the electrical resistivity and decreases the Seebeck coefficient (n-type) while reducing the thermal conductivity by ∼30%. The resultant power factor offsets the decrease in total thermal conductivity giving rise to a substantial decrease in ZT. Principal thermoelectric properties of InxM4Sb12 (M = Co, Rh, Ir) phases are compared. As iridium is a 5d transition metal, zero field cooled (ZFC) magnetization were performed to unravel the effect of spin-orbit interaction on the electronic properties. These results serve to advance the understanding of filled skutterudites, and provide additional insight on the less explored smaller "rattlers" and their influence on key thermoelectric properties.
High Fill-Factor Transport Experiments on the HCX
International Nuclear Information System (INIS)
Prost, L R; Seidl, P A; Lund, S M
2004-01-01
Heavy-ion induction linacs have application as drivers for high energy density physics studies and ultimately as drivers for inertial fusion energy. Experiments on the High-Current Experiment (HCX) at LBNL explore heavy-ion beam transport at high fill factors (i.e., the ratio of the maximum transverse extent of the beam to the physical aperture). The fill factor has a large impact on the cost of multi-beam induction accelerators, the 80% fill factor compared with 60% would reduce the cost of an HIF driver by about 1/3. With a coasting low-emittance 1 MeV K + beam, transport through ten electrostatic quadrupoles was achieved at high beam fill factor (80%) without observed emittance growth and with little beam loss ((le) 1%), even though the initial beam distribution is neither ideal nor in thermal equilibrium, see Figure. While 10 quadrupoles are too few for settling questions of emittance evolution in a long system, they are very relevant for studying the rapid initial evolution of the emittance and beam profile that is expected in the front end of an accelerator. Studies at higher fill factors are planned, so that the failure mode can be established. Good envelope control was achieved, suggesting that, in a longer lattice of similar design, rematching only every ten lattice periods (at 80% fill factor) will be sufficient. Agreement was reached between an improved envelope model and the data. Improvements to the model are: realistic quadrupole fringe fields based on 3D field calculations; quadrupole E z from the 3D lattice structure and corresponding radial focusing force; and corrections due to the grounded slit plates of the intercepting diagnostics that short out the self-field of the beam near those plates. We also find that understanding and controlling the time dependence of the envelope parameters is critical to achieving high fill factors, notably because of the injector and matching section dynamics
Fractionation and determination of total antioxidant capacity, total ...
African Journals Online (AJOL)
DEYAKS PLC
2014-01-29
Jan 29, 2014 ... the treatment of stomach and rheumatic pains, inflamma- tory disorders ... reagent and expressed as gallic acid equivalent (GAE). Exactly. 0.25 ml .... anthocyanins and antioxidant activity following simulated gastro- intestinal ...
A simple capacitance sensor for void fraction measurement in gas-liquid two-phase flow
International Nuclear Information System (INIS)
Silva, Luiz C.R.P.; Faccini, José L.H.; Farias, Marcos S.; Su, Jian
2017-01-01
In this work we present a simple and inexpensive capacitance sensor for time averaging void fraction measurement of gas-liquid two-phase flow, which was developed at Experimental Thermal hydraulics Laboratory in the Nuclear Engineering Institute, IEN/CNEN. The sensor is a non-invasive device causing no flow disturbances. It is formed by two parallel plates and four electronic circuits: a signal input circuit, an amplification circuit, a frequency generator, and a power supply circuit. The frequency generator applies a sinusoidal signal with appropriate frequency into the signal input circuit which converts the capacitance variation value (or void fraction) of the two-phase flow into a voltage signal that goes to the amplifier stage; the output signal of the amplifier stage will be an input to an analogic/digital converter, installed inside of a computer, and it will provide interpretation of the signal behavior. The capacitance sensor was calibrated by using a horizontal acrylic tube filled with a known volume of water. (author)