WorldWideScience

Sample records for total exposure dose

  1. Total Risk Management for Low Dose Radiation Exposures

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Sterc, D.

    2012-01-01

    health. This view is supported with numerous evidences, and explained with beneficial effects from the increased activity of immune system activated with small radiation exposures. Finally, theory in between is that small doses are less than linearly proportionally harmful and that they are presenting a much smaller risks than according to the LNT. This view is derived from the use of different evidences. Difficulties to find one single theory about effects of small radiation doses are related to existence of huge variability and uncertainty in the evidence data. This is very hard experimental and theoretical problem. It will require lots of additional research to reduce these uncertainties and find final theory. This might be too late for the number of people affected in different ways with current single most conservative LNT approach. The problem with the conservative LNT regulatory approach is resulting in enormous additional costs of nuclear energy and medical applications. Which is reasonable and acceptable during the regular operation when source is high and concentrated. But, this becomes unreasonable huge economic burden after accidents and for cleanups with nuclear facilities. Similar problem arises with restriction of medical examinations and treatments based on over conservative risk estimate. Special circumstances are with evacuated people from contaminated areas where they are on the one side saved from small radiation exposures, and on the other side exposed to years of life away from their home and with numerous direct and indirect additional risks (i.e., stress, social problems, etc.). It seems reasonable that some alternative (total) risk management approach might be much more suitable for this situation. Evacuation of people from contaminated area with small doses sources should not be done when that induces larger risks from even what is expected from radiation based on LNT. Similar total risk management could be also applied for with medical

  2. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  3. Calculating radiation exposure and dose

    International Nuclear Information System (INIS)

    Hondros, J.

    1987-01-01

    This paper discusses the methods and procedures used to calculate the radiation exposures and radiation doses to designated employees of the Olympic Dam Project. Each of the three major exposure pathways are examined. These are: gamma irradiation, radon daughter inhalation and radioactive dust inhalation. A further section presents ICRP methodology for combining individual pathway exposures to give a total dose figure. Computer programs used for calculations and data storage are also presented briefly

  4. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co γ rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for γ-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD 50 is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD 50 can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate

  5. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co gamma rays in a specially constructed facility. The exposure rates were 5, 19, 17 or 35 R/day, and the exposures were terminated at 600, 1400, 2000 or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for gamma-ray exposures given at a number of exposure rates. They also allow comparison of the relativeimportance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 344 R (258 rads) delivered at 15 R/minute to approximately 4000 R (approximately 3000 rads) at 10 R/day. Over this entire range, the LD 50 is dependent upon haematopoietic damage. At 5 R/day and less, no definitive LD 50 can be determined; there is nearly normal continued haematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in the organ systems. Although the experiment is not complete, interim data allow serveral important conclusions. Terminated exposures, while not as effective as irradiation continued until death, can produce myelogenous leukaemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates appear more damaging than higher rates on the basis of the rate and degree of haematological recovery that occurs after termination of irradiation. Thus, the rate of haematologic depression, the nadir of the depression and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the first two are directly related to exposure rate. ( author)

  6. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  7. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    of a total hip arthroplasty implant, exposure values increased threefold at some anatomic locations and surpassed 1 mSv, the generally accepted threshold for concern. Radiation exposure to radiosensitive organs increased up to threefold after total hip implantation with automatic exposure control and up to approximately 1.5 times with the manual protocol. Doses were greater with manual exposures than with automatic exposure control (except at the control probe on the stomach, where exposure was negligible, as expected). However, after implant placement, doses increased more with automatic exposure control than with manual exposure. This difference can be attributed to increased scatter and the difficulty of dose modification because of the density of the implant. Current radiographic protocols should be reassessed to determine if the benefits of frequent radiographs outweigh the newly demonstrated risks.

  8. Implication of fractionated dose exposures in therapeutic gain

    International Nuclear Information System (INIS)

    Kim, Hye-Jin; Lee, Min-Ho; Kim, Eun-Hee

    2016-01-01

    Radiation therapy pursues killing tumor cells while sparing normal cells from the radiation exposure. Stereotactic radiosurgery (SRS) is a cancer treatment modality that delivers a high dose in a single operation. This high-dose single operation shortens the treatment course, but can increase the risk of normal cell damage. Normal cell damage can be reduced by employing multi-directional exposures for an increasing number of isocenters. In this study, we investigated whether therapeutic benefits would be expected by employing new dose fractionation patterns at a high-dose single operation. The conventional single-dose operation in brain tumor radiosurgery is performed by delivering fractionated uniform doses. According to Figs. 2 and 3, the conventional radiosurgery might have obtained some therapeutic benefit by employing the fractionated uniform-dose exposures instead of a single-dose exposure. We suggest that further therapeutic gain be expected by employing the fractionated radiation exposures in an increasing dose pattern. Until ensuring our suggestion, the significance in gain of cell surviving should be verified for all three dose patterns with both normal and tumor cells. The investigation whether normal and tumor cells show the same responses to the fractionated dose exposures at lower and higher than 15 Gy of total dose is also reserved for future work

  9. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  10. Low dose radiation exposure and atherosclerosis in ApoE-/- mice

    International Nuclear Information System (INIS)

    Mitchel, R.E.J.; Hasu, M.; Bugden, M.; Wyatt, H.; Little, M.; Hildebrandt, G.; Priest, N.D.; Whitman, S.C.

    2010-01-01

    The hypothesis that single low dose exposures (0.025-0.5 Gy) to low LET radiation, given at either high (240 mGy/min) or low (1 mGy/min) dose rate, would promote aortic atherosclerosis was tested in female C57BI/6 mice genetically predisposed to this disease (ApoE-/-). Mice were exposed either at early stage disease (2 months of age) and examined 3 or 6 months later, or at late stage disease (8 months of age) and examined 2 or 4 months later. Compared to unexposed controls, all doses given at low or high dose rate at early stage disease had significant inhibitory effects on lesion growth and, at 25 or 50 mGy, on lesion frequency. No dose given at low dose rate had any effect on total serum cholesterol, but this was elevated by every dose given at high dose rate. Exposures at low dose rate had no effect on the percentage of lesion lipids contained within macrophages, and, at either high or low dose rate, had no significant effect on lesion severity. Exposure at late stage disease, to any dose at high dose rate, had no significant effect on lesion frequency, but at low dose rate some doses produced a small transient increase in this frequency. Exposure to low doses at low, but not high dose rate, significantly, but transiently reduced average lesion size, and at either dose rate transiently reduced lesion severity. Exposure to any dose at low dose rate (but not high dose rate) resulted in large and persistent decreases in serum cholesterol. These data indicate that a single low dose exposure, depending on dose and dose rate, generally protects against various measures of atherosclerosis in genetically susceptible mice. This result contrasts with the known, generally detrimental effects of high doses on this disease in the same mice, suggesting that a linear extrapolation of risk from high doses is not appropriate. (author)

  11. Studies on the establishment of maximum permissible exposure dose for reference Korean

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.C.; Kim, C.B.; Chung, K.H.; Kim, S.L.; Kim, M.J.

    1981-01-01

    In order to establish the Reference Korean and maximum permissible exposure dose of Reference Korean, for the first year a total of 9,758 males and 7,019 females were surveyed for the height, weight, a body surface area, and a total of 879 individuals of 180 households located in different 30 localities were analyzed for food consumption and a total of radioactive substances (β-ray) contained in food per capita per day. In this report the external and internal exposure dose were also estimated on the basis of data mostly published in other country as well as in Korea in part

  12. Low dose radiation exposure and atherosclerosis in ApoE{sup -/-} mice

    Energy Technology Data Exchange (ETDEWEB)

    Mitchel, R.E.J. [Atomic Energy of Canada Limited, Chalk River, ON (Canada); Hasu, M. [Univ. of Ottawa, Department of Pathology and Lab. Medicine, and Cellular and Molecular Medicine, Ottawa, ON (Canada); Univ. of Ottawa Heart Inst., Vascular Biology Group, Ottawa, ON (Canada); Bugden, M.; Wyatt, H. [Atomic Energy of Canada Limited, Chalk River, ON (Canada); Little, M. [Imperial Coll., Faculty of Medicine, St. Marys Campus, London (United Kingdom); Hildebrandt, G. [Univ. Hospital, Dept. of Radiotherapy, Rostock (Germany); Priest, N.D. [Atomic Energy of Canada Limited, Chalk River, ON (Canada); Whitman, S.C. [Univ. of Ottawa, Department of Pathology and Lab. Medicine, and Cellular and Molecular Medicine, Ottawa, ON (Canada); Univ. of Ottawa Heart Inst., Vascular Biology Group, Ottawa, ON (Canada)

    2010-07-01

    The hypothesis that single low dose exposures (0.025-0.5 Gy) to low LET radiation, given at either high (240 mGy/min) or low (1 mGy/min) dose rate, would promote aortic atherosclerosis was tested in female C57BI/6 mice genetically predisposed to this disease (ApoE-/-). Mice were exposed either at early stage disease (2 months of age) and examined 3 or 6 months later, or at late stage disease (8 months of age) and examined 2 or 4 months later. Compared to unexposed controls, all doses given at low or high dose rate at early stage disease had significant inhibitory effects on lesion growth and, at 25 or 50 mGy, on lesion frequency. No dose given at low dose rate had any effect on total serum cholesterol, but this was elevated by every dose given at high dose rate. Exposures at low dose rate had no effect on the percentage of lesion lipids contained within macrophages, and, at either high or low dose rate, had no significant effect on lesion severity. Exposure at late stage disease, to any dose at high dose rate, had no significant effect on lesion frequency, but at low dose rate some doses produced a small transient increase in this frequency. Exposure to low doses at low, but not high dose rate, significantly, but transiently reduced average lesion size, and at either dose rate transiently reduced lesion severity. Exposure to any dose at low dose rate (but not high dose rate) resulted in large and persistent decreases in serum cholesterol. These data indicate that a single low dose exposure, depending on dose and dose rate, generally protects against various measures of atherosclerosis in genetically susceptible mice. This result contrasts with the known, generally detrimental effects of high doses on this disease in the same mice, suggesting that a linear extrapolation of risk from high doses is not appropriate. (author)

  13. 1. Dose reduction of occupational exposure in cardiac catheterization and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Yoshimi [Kyushu Kosei Nenkin Hospital, Kitakyushu, Fukuoka (Japan); Matsumoto, Kunihiro; Fujihashi, Hiroshi; Umeda, Kazuhiro

    2000-08-01

    Occupational exposure to scattered radiation and protective equipment was assessed in 4 medical institutions in Kyushu, Japan. The areas where scattered radiation occurred, the scattered radiation dose in the operator's position, fluoroscopy time, the number of cinematography sessions, and annual number of patients were assessed, and the annual scattered radiation dose to the operator was estimated. Approximately 90% of scattered radiation was generated by the subject and the collimator. Measurement of scattered radiation during coronary arteriography yielded a dose of 255-1200 [{mu}Sv/hr.] during fluoroscopy and 3.8-26.7 [{mu}Sv/10 sec.] during radiography. The duration of fluoroscopy for ablation was much longer than during general examinations and PTCA, suggesting a possible contribution to occupational exposure. The data for the past 5 years show no marked change in total number of catheterizations, but the number of ablations has rapidly increased. Ablation requires specific skills, and thus it is frequently performed by only a few staff members, resulting in exposure being concentrated in a few specific persons. The estimated doses of scattered radiation to the eyes and thyroid gland, which are assumed to be the most highly exposed sites, were 116.2 [mSv/year] during fluoroscopy and 8.9 [mSv/year] during radiography, for a total of 125.1 [mSv/year]. This dose is very close to the maximum occupational exposure dose recommended by International Commission on Radiological Protection (ICRP), i.e., 150 [mSv/year]. A protective device that does not impose a burden on the operator or limit the functions of x-ray units was installed on top of the examining table as a measure to reduce the occupational dose. In an experiment using this device the scattered radiation dose during inguinal puncture decreased from 0.8 [mSv/hr.] to 0.02 [mSv/hr.], and the shielding rate was 2.5%. The dose was reduced 97.5%. The authors conclude that radiological personnel must make

  14. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  15. Estimation of effective dose to public from external exposure to natural background radiation in saudi arabia

    International Nuclear Information System (INIS)

    Khalid, A. A.

    2003-01-01

    The effective dose values in sixteen cities in Saudi Arabia due to external exposure to natural radiation were evaluated. These doses are based on natural background components including external exposure to terrestrial radiation and cosmic rays. The importance of evaluating the effective dose to the public due to external exposure to natural background radiation lies in its epidemiological and dosimetric importance and in forming a basis for the assessment of the level of radioactive contamination or pollution in the environment in the future. The exposure to terrestrial radiation was measured using thermoluminescent dosimeters (TLD). The exposure from cosmic radiation was determined using empirical correlation. The values evaluated for the total annual effective dose in all cities were within the world average values. The highest total annual effective dose measured in Al-Khamis city was 802 μSv/y, as compared to 305 μSv/y in Dammam city, which was considered the lowest value

  16. Changes in patient exposure doses from diagnostic radiological procedures in Japan, 1974-2007

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Ito, Yusuke; Asada, Yasuki; Hattori, S.; Kamei, S.; Koga, Sukehiko

    2008-01-01

    We have investigated changes in exposure dose in Japan in terms of the same items since 1974. An assessment was made of changes in exposure dose during a period of 33 years. Nationwide investigation was conducted six times from 1974 to 2007 with regard to 14 target areas (21 kinds of projections). The investigations we examined is as follows: tube voltage (kV), tube current (mA), exposure time (sec), focus surface distance, thickness of total filtration and type of generator system for diagnostic radiography for a typical patient. Entrance surface doses were evaluated in terms of the respective exposure conditions based on basic experiment. The results showed that the exposure doses decreased to less than 50% during a 15-year period till 1994, with the exposure doses in 1974 assumed to be 100%. The exposure doses in 2007 were equivalent to, or increased over the exposure doses in 1994 at some areas. A comparison with the international basic safety standard for protection against ionizing radiation set up by the IAEA, that is, the so-called guidance level, indicated that the exposure doses in 2007 were less than the standard in all areas. The comparison with past investigations also demonstrated that F/S system using film-intensifying screen has been increasingly replaced with computed radiography (CR) system using imaging plates (IP) and flat panel digital radiography (FPD) system. In the investigation in 2007, an attempt was made of a comparison between exposure dose by the digital radiography system and that by the F/S system as well. It was clarified that there was no large difference in the exposure dose between those systems. (author)

  17. Use of dose constraints in public exposure

    International Nuclear Information System (INIS)

    Tageldein, Amged

    2015-02-01

    An overview of the dose constraints in public exposures has been carried out in this project. The establishment, development and the application of the concept of dose constraints are reviewed with regards to public exposure. The role of dose constraints in the process of optimization of radiation protection was described and has been showed that the concept of the dose constraints along with many other concept of radiation protection is widely applied in the optimization of exposure to radiation. From the beginning of the establishment of dose constraints as a concept in radiation protection, the International Commission of Radiological Protection (ICRP) has published a number of documents that provides detailed application related to radiation protection and safety of public exposure from ionizing radiation. This work provides an overview of such publications and related documents with special emphasis on optimization of public exposure using dose constraints. (au)

  18. Use of dose constraints in medical exposure

    International Nuclear Information System (INIS)

    Mutanga, N. V. T.

    2013-04-01

    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Medical exposure to radiation is exposure incurred by patients as part of their own medical or dental diagnosis or treatment; by persons, other than those occupationally exposed, knowingly, while voluntarily helping in the support and comfort of patients; and by volunteers in a programme of biomedical research involving their exposure. Because it is planned exposure, medical exposure has to conform to a set of principles of protection that apply equally to all controllable exposure situations: the principle of justification, the principle of optimisation of protection, and the principle of application of limits on maximum doses in planned situations. In this study the concept of dose constraints is being scrutinized to see if it can be applied in medical exposures and the benefits of such restrictions. Dose constraints can only be applied to exposure to persons voluntary helping in the support and comfort of patients as well as volunteers in the programme of biomedical research. There are no dose constraints for patients but the concept of reference levels applies. (au)

  19. An ignored risk factor in toxicology: The total imprecision of exposure assessment

    DEFF Research Database (Denmark)

    Grandjean, Philippe; Budtz-Jørgensen, Esben

    2010-01-01

    twice as much for maternal hair. The total imprecision of these biomarkers much exceeded the normal laboratory variability of less than 5%. Such imprecision can cause underestimation of dose-related toxicity, and data analysis should therefore include sensitivity analyses that take this factor...... were determined in cord blood, cord tissue, and maternal hair. We determined their mutual correlations and their associations with the child's neurobehavioral effect variables at age 7 years. The exposure biomarkers correlated well with one another, but the cord blood mercury concentration showed......Quality assurance of exposure biomarkers usually focuses on laboratory performance only. Using data from a prospective birth cohort study in the Faroe Islands, we have assessed the total imprecision of exposure biomarkers. As biomarkers of prenatal methylmercury exposure, mercury concentrations...

  20. Dose assessment of an accidental exposure at IPNS

    International Nuclear Information System (INIS)

    Torres, M.M.C.

    1996-01-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose rates ranged from 550 mrem/min to 2,850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  1. Dose evaluation for external exposure in radiation accidents

    International Nuclear Information System (INIS)

    Maruyama, Takashi

    1989-01-01

    Abnormal exposures including emergency and accidental are categorized into external exposure and internal contamination, although both of these may be associated with external contamination. From a point of view of lifesaving in the abnormal exposures, it is primarily important to evaluate radiation dose of exposed persons as soon as possible. This report reviews the status of early dosimetry in the accidental exposures and discusses the optimum methodology of the early dose determination for external exposures in abnormal exposures. Personal monitors generally give an indication of dose to an exposed person only at a single part of the body. The data obtained from the personal monitors should be interpreted with care and in the light of information about the circumstances of exposure. In most cases, the records of environmental monitors or the survey with area monitors provide valuable information on the radiation fields. In the some cases, the reconstruction of the abnormal exposure is required for the dose evaluation by means of phantom experiments. In the case of neutron exposures, activation products in the body or its components or personnel possession can be useful for the early dosimetry. If the dose received by the whole body is evaluated as being very high, clinical observations and biological investigations may be more important guide to initial medical treatment than the early dosimetry. For the dose evaluation of general public, depending on the size of abnormal exposure, information that could be valuable in the assessment of abnormal exposures will come from the early dose estimates with environmental monitors and radiation survey meters. (author)

  2. Hormesis of Low Doses of Ionizing Radiation Exposure on Immune System

    International Nuclear Information System (INIS)

    Ragab, M.H.; Abbas, M.O.; El-Asady, R.S.; Amer, H.A.; El-Khouly, W.A.; Shabon, M.H.

    2015-01-01

    The effect of low doses of ionizing radiation on the immune system has been a controversial subject. To evaluate the effect of low-doses γ-irradiation exposure on immune system. An animal model, using Rattus Rattus rats was used. The rats were divided into groups exposed to either continuous or fractionated 100, 200, 300, 400 and 500 mSv of radiation and compared to control rats that did not receive radiation. All groups were exposed to a total white blood count (Wcs), lymphocyte count and serum IgG level measurement, as indicators of the function of the cell-mediated (T lymphocytes) and the humoral (B lymphocytes) immune system. The results of the current study revealed that the counts of total leukocytes (WBCs) and lymphocytes, as well as the serum level of IgG were increased significantly in rats receiving low dose radiation, indicating enhancement of immune system. The data suggests that low-dose gamma-radiation improved hematological parameters and significantly enhances immune response indices of the exposed rats. These findings are similar to the radiation adaptive responses in which a small dose of pre irradiation would induce certain radiation resistance and enhances the cell response after exposure to further irradiation doses The applied low doses used in the present study may appear effective inducing the radio adaptive response. Farooqi and Kesavan (1993) and Bravard et al. (1999) reported that the adaptive response to ionizing radiation refers to the phenomenon by which cells irradiated with low (cGy) or sublethal doses (conditioning doses) become less susceptible to genotoxic effects of a subsequent high dose (challenge dose, several Gy).

  3. Operator dependency of the radiation exposure in cardiac interventions: feasibility of ultra low dose levels

    International Nuclear Information System (INIS)

    Emre Ozpelit, Mehmet; Ercan, Ertugrul; Pekel, Nihat; Tengiz, Istemihan; Yilmaz, Akar; Ozpelit, Ebru; Ozyurtlu, Ferhat

    2017-01-01

    Introduction: Mean radiation exposure in invasive cardiology varies greatly between different centres and interventionists. The International Commission on Radiological Protection and the EURATOM Council stipulate that, despite reference values, 'All medical exposure for radiodiagnostic purposes shall be kept as low as reasonably achievable' (ALARA). The purpose of this study is to establish the effects of the routine application of ALARA principles and to determine operator and procedure impact on radiation exposure in interventional cardiology. Materials and methods: A total of 240 consecutive cardiac interventional procedures were analysed. Five operators performed the procedures, two of whom were working in accordance with ALARA principles (Group 1 operators) with the remaining three working in a standard manner (Group 2 operators). Radiation exposure levels of these two groups were compared. Results: Total fluoroscopy time and the number of radiographic runs were similar between groups. However, dose area product and cumulative dose were significantly lower in Group 1 when compared with Group 2. Radiation levels of Group 1 were far below even the reference levels in the literature, thus representing an ultra-low-dose radiation exposure in interventional cardiology. Conclusion: By use of simple radiation reducing techniques, ultra-low-dose radiation exposure is feasible in interventional cardiology. Achievability of such levels depends greatly on operator awareness, desire, knowledge and experience of radiation protection. (authors)

  4. Occupational exposures and doses thereform: a synoptic view of worldwide scenario (summary of UNSCEAR 1993 data)

    International Nuclear Information System (INIS)

    Nagaratham, A.; Jain, S.C.; Gupta, M.M.

    1995-01-01

    The present review paper is a summary of the extensive data reported by UNSCEAR 1993 on occupational exposure levels worldwide. The data are based mainly on responses to a UNSCEAR survey on occupational exposures. Worldwide extrapolation was done from the reported data based on GNP. Data have been analysed for three 5-year periods, 1975-79, 1980-84 and 1985-89. Values are given for the total number of monitored workers, the average annual individual doses (related to average individual risk), annual collective dose (related to the impact of the practice), and certain other parameters. Exposures have been evaluated for 5 broad categories, viz., nuclear fuel cycle, defence activities, industrial uses, medical uses, and enhanced occupational exposure to natural sources. The annual collective doses for these categories are respectively 2500, 250, 510, 1000 and 8600 man-Sv for a total of 9.2 million workers. Average individual doses were respectively 2.9, 0.7, 0.9, 0.5 and 1.7 mSv respectively. Data for India are discussed separately for each category. (author). 3 refs., 4 tabs

  5. TESS-based dose-response using pediatric clonidine exposures.

    Science.gov (United States)

    Benson, Blaine E; Spyker, Daniel A; Troutman, William G; Watson, William A

    2006-06-01

    The toxic and lethal doses of clonidine in children are unclear. This study was designed to determine whether data from the American Association of Poison Control Centers Toxic Exposure Surveillance System (TESS) could be utilized to determine a dose-response relationship for pediatric clonidine exposure. 3,458 single-substance clonidine exposures in children TESS from January 2000 through December 2003 were examined. Dose ingested, age, and medical outcome were available for 1550 cases. Respiratory arrest cases (n = 8) were classified as the most severe of the medical outcome categories (Arrest, Major, Moderate, Mild, and No effect). Exposures reported as a "taste or lick" (n = 51) were included as a dose of 1/10 of the dosage form involved. Dose ranged from 0.4 to 1980 (median 13) microg/kg. Weight was imputed based on a quadratic estimate of weight for age. Dose certainty was coded as exact (26% of cases) or not exact (74%). Medical outcome (response) was examined via logistic regression using SAS JMP (release 5.1). The logistic model describing medical outcome (P TESS data can provide the basis for a statistically sound description of dose-response for pediatric clonidine poisoning exposures.

  6. Enhancement of Transistor-to-Transistor Variability Due to Total Dose Effects in 65-nm MOSFETs

    CERN Document Server

    Gerardin, S; Cornale, D; Ding, L; Mattiazzo, S; Paccagnella, A; Faccio, F; Michelis, S

    2015-01-01

    We studied device-to-device variations as a function of total dose in MOSFETs, using specially designed test structures and procedures aimed at maximizing matching between transistors. Degradation in nMOSFETs is less severe than in pMOSFETs and does not show any clear increase in sample-to-sample variability due to the exposure. At doses smaller than 1 Mrad( SiO2) variability in pMOSFETs is also practically unaffected, whereas at very high doses-in excess of tens of Mrad( SiO2)-variability in the on-current is enhanced in a way not correlated to pre-rad variability. The phenomenon is likely due to the impact of random dopant fluctuations on total ionizing dose effects.

  7. Dose assessment of an accidental exposure at the IPNS

    International Nuclear Information System (INIS)

    Campos Torres, M.M.

    1995-02-01

    Seven different methods were used to estimate the dose rate to a female worker who was accidentally exposed in the neutron PHOENIX beamline at the IPNS. Theoretical and measured entrance dose ranged from 550 mrem/min to 2850 mrem/min. Theoretical estimates were based on a Monte Carlo simulation of a spectrum provided by IPNS (Crawford Spectrum). Dose measurements were made with TLDs on phantoms and with ionization chambers in a water phantom. Estimates of the whole body total effective dose equivalent (TEDE) rate ranged from 5.2 mrem/min to 840 mrem/min. Assumed and measured quality factors ranged from 2.6 to 11.8. Cytogenetic analyses of blood samples detected no positive exposure. The recommended TEDE rate was 158 mrem/min. The TEDE was 750 mrem

  8. The impact of prodromal symptoms on dose monitoring for whole body radiation exposure

    International Nuclear Information System (INIS)

    Hartmann, A.; Bojar, H.; Zamboglou, N.; Pape, H.; Schnabel, T.; Schmitt, G.

    1994-01-01

    The triage of victims after radiation injury is complicated by missing dose values and the fact that most tissues react after a latency period. We evaluated 63 patients undergoing total body irradiation as conditioning regime before bone marrow transplantation in order to find a relation between prodromal symptoms and dose. Emesis after radiation exposure hints to doses greater than 1.5 Gy. A rise of body temperature above 37 C up to five hours after exposure is related to doses exceeding 2.5 Gy, while an acute onset of diarrhoea is an indicator of a severe accident with more than 9 Gy. Besides blood counts and chromosome analyses a careful evaluation of prodromal symptoms can help to classify the severity of radiation accidents. (orig./MG) [de

  9. TESS-based dose-response using pediatric clonidine exposures

    International Nuclear Information System (INIS)

    Benson, Blaine E.; Spyker, Daniel A.; Troutman, William G.; Watson, William A.

    2006-01-01

    Objective: The toxic and lethal doses of clonidine in children are unclear. This study was designed to determine whether data from the American Association of Poison Control Centers Toxic Exposure Surveillance System (TESS) could be utilized to determine a dose-response relationship for pediatric clonidine exposure. Methods: 3458 single-substance clonidine exposures in children <6 years of age reported to TESS from January 2000 through December 2003 were examined. Dose ingested, age, and medical outcome were available for 1550 cases. Respiratory arrest cases (n = 8) were classified as the most severe of the medical outcome categories (Arrest, Major, Moderate, Mild, and No effect). Exposures reported as a 'taste or lick' (n = 51) were included as a dose of 1/10 of the dosage form involved. Dose ranged from 0.4 to 1980 (median 13) μg/kg. Weight was imputed based on a quadratic estimate of weight for age. Dose certainty was coded as exact (26% of cases) or not exact (74%). Medical outcome (response) was examined via logistic regression using SAS JMP (release 5.1). Results: The logistic model describing medical outcome (P < 0.0001) included Log dose/kg (P 0.0000) and Certainty (P = 0.045). Conclusion: TESS data can provide the basis for a statistically sound description of dose-response for pediatric clonidine poisoning exposures

  10. On the radiation exposure dose and health management history during 50 years of x-ray working

    International Nuclear Information System (INIS)

    Yoshida, Tomihiro

    1981-01-01

    My X-ray working history has become 50 years at the end of April, 1980. At this chance, the following data were summarized; the case numbers of X-ray photographs (517,132 cases), total amounts of radiation exposure dose (66.85 roentgen) and the results of blood test, which were experienced during past 50 years. The amounts of exposure dose during 35 years till 1965 were measured using my own method, which measured the film blackening as 30 milli-roentgen per week by certain standard method. After 1966 till 1980, the exposure dose were recorded using that of the film-badge service of Nippon Hoan Yohin Kyokai. The total amounts of exposure dose during 50 years were about 1/4 of D = 5 (N - 18). The results of blood test during last 27 years were found to be normal values. Then, it is happy to say that my body has been protected completely, from radiation hazard as a result of taking radiation protection and checking blood test always at my daily radiation works. The data of my own experiences during 50 years are summarized and reported in this paper. (author)

  11. Estimation of dose and exposure at sentinel node study

    International Nuclear Information System (INIS)

    Skopljak, A.; Kucukalic-Selimovic, E.; Beslic, N.; Begic, A.; Begovic-Hadzimuratovic, S.; Drazeta, Z.; Beganovic, A.

    2005-01-01

    The purpose of this study was to estimate the dose end exposure in staff involved in sentinel node procedure for breast cancer patients. The Institute of Nuclear Medicine in Sarajevo uses a protocol for lymphoscintigraphy of the sentinel node whereby 13 MBq of 9 9mT c nanocoll are used. In this study, we measured radiation doses and exposure of a nuclear medicine physician and a technologist, as well as a surgeon performing sentinel node lymphoscintigraphy and biopsy. Dose and exposure were calculated using the equation in which we have gamma constant for 9 9mT c. Calculations were made for different times of exposure and distance. In Table 1. we estimated the dose and exposure during sentinel node study. Radiation levels were very low and the most exposed hospital staff performing sentinel node study were nuclear medicine physicians. The doses on the hands of surgeons were negligible 8 hours after exposure.(author)

  12. Dynamic interactions between hydrogeological and exposure parameters in daily dose prediction under uncertainty and temporal variability

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Vikas, E-mail: vikas.kumar@urv.cat [Department of Chemical Engineering, Rovira i Virgili University, Tarragona 43007 (Spain); Barros, Felipe P.J. de [Sonny Astani Department of Civil and Environmental Engineering, University of Southern California, Los Angeles 90089, CA (United States); Schuhmacher, Marta [Department of Chemical Engineering, Rovira i Virgili University, Tarragona 43007 (Spain); Fernàndez-Garcia, Daniel; Sanchez-Vila, Xavier [Hydrogeology Group, Department of Geotechnical Engineering and Geosciences, University Politècnica de Catalunya-BarcelonaTech, Barcelona 08034 (Spain)

    2013-12-15

    Highlights: • Dynamic parametric interaction in daily dose prediction under uncertainty. • Importance of temporal dynamics associated with the dose. • Different dose experienced by different population cohorts as a function of time. • Relevance of uncertainty reduction in the input parameters shows temporal dynamism. -- Abstract: We study the time dependent interaction between hydrogeological and exposure parameters in daily dose predictions due to exposure of humans to groundwater contamination. Dose predictions are treated stochastically to account for an incomplete hydrogeological and geochemical field characterization, and an incomplete knowledge of the physiological response. We used a nested Monte Carlo framework to account for uncertainty and variability arising from both hydrogeological and exposure variables. Our interest is in the temporal dynamics of the total dose and their effects on parametric uncertainty reduction. We illustrate the approach to a HCH (lindane) pollution problem at the Ebro River, Spain. The temporal distribution of lindane in the river water can have a strong impact in the evaluation of risk. The total dose displays a non-linear effect on different population cohorts, indicating the need to account for population variability. We then expand the concept of Comparative Information Yield Curves developed earlier (see de Barros et al. [29]) to evaluate parametric uncertainty reduction under temporally variable exposure dose. Results show that the importance of parametric uncertainty reduction varies according to the temporal dynamics of the lindane plume. The approach could be used for any chemical to aid decision makers to better allocate resources towards reducing uncertainty.

  13. Work to save dose: contrasting effective dose rates from radon exposure in workplaces and residences against the backdrop of public and occupational limits

    International Nuclear Information System (INIS)

    Whicker, Jeffrey J.; Mcnaughton, Michael W.

    2009-01-01

    Office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the non-mine workplaces are lacking. Additionally, there are few, if any, comparative analyses of radon exposures at more 'typical' workplace with residential exposures within the same county. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about 8 times greater exposure at home than while in the office (2.3 mSv yr- versus 0.3 mSv yr-). The estimated effective dose rate for a more homebound person was about 3 mSv yr-. Estimating effective doses from background radon exposure in the same county as Los Alamos National Laboratory, with thousands of'radiological workers,' highlights interesting contrasts in radiation protection standards that span public and occupational settings. For example, the effective dose rate from background radon exposure in unregulated office spaces ranged up to 1.1 mSv yr-, which is similar to the 1 mSv yr- threshold for regulation ofa 'radiological worker,' as defined in the Department of Energy regulations for occupational exposure. Additionally, the estimated average effective dose total of> 3 mSv yf from radon background exposure in homes stands in contrast to the 0.1 mSv yr- air pathway

  14. Work to save dose: contrasting effective dose rates from radon exposure in workplaces and residences against the backdrop of public and occupational limits

    Energy Technology Data Exchange (ETDEWEB)

    Whicker, Jeffrey J [Los Alamos National Laboratory; Mcnaughton, Michael W [Los Alamos National Laboratory

    2009-01-01

    Office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the non-mine workplaces are lacking. Additionally, there are few, if any, comparative analyses of radon exposures at more 'typical' workplace with residential exposures within the same county. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about 8 times greater exposure at home than while in the office (2.3 mSv yr-! versus 0.3 mSv yr-!). The estimated effective dose rate for a more homebound person was about 3 mSv yr-!. Estimating effective doses from background radon exposure in the same county as Los Alamos National Laboratory, with thousands of'radiological workers,' highlights interesting contrasts in radiation protection standards that span public and occupational settings. For example, the effective dose rate from background radon exposure in unregulated office spaces ranged up to 1.1 mSv yr-!, which is similar to the 1 mSv yr-! threshold for regulation ofa 'radiological worker,' as defined in the Department of Energy regulations for occupational exposure. Additionally, the estimated average effective dose total of> 3 mSv yf! from radon background exposure in homes stands in

  15. Total-dose hardness assurance for low earth orbit

    International Nuclear Information System (INIS)

    Maurer, R.H.; Suter, J.J.

    1987-01-01

    The Low Earth Orbit radiation environment has two significant characteristics that make laboratory simulation exposures difficult: (1) a low dose rate and (2) many cycles of low dose accumulation followed by dose-free annealing. Hardness assurance considerations for this environment are discussed and related to data from the testing of Advanced Low Power Schottky and High-speed CMOS devices

  16. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  17. Doses from radiation exposure

    CERN Document Server

    Menzel, H G

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection's (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP's 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effecti...

  18. Dose level of occupational exposure in China

    International Nuclear Information System (INIS)

    Tian, Y.; Zhang, L.; Ju, Y.

    2008-01-01

    This paper discusses the dose level of Chinese occupational exposures during 1986-2000. Data on occupational exposures from the main categories in nuclear fuel cycle (uranium enrichment and conversion, fuel fabrication, reactor operation, waste management and research activity, except for uranium mining and milling because of the lack of data), medical uses of radiation (diagnostic radiation, nuclear medicine and radiotherapy) and industrial uses of radiation (industrial radiography and radioisotope production) are presented and summarised in detail. These are the main components of occupational exposures in China. In general, the average annual effective doses show a steady decreasing trend over periods: from 2.16 to 1.16 mSv in medical uses of radiation during 1990-2000; from 1.92 to 1.18 mSv in industrial radiography during 1990-2000; from 8.79 to 2.05 mSv in radioisotope production during the period 1980-2000. Almost all the average annual effective doses in discussed occupations were lower than 5 mSv in recent years (except for well-logging: 6.86 mSv in 1999) and no monitored workers were found to have received the occupational exposure exceeding 50 mSv in a single year or 100 mSv in a five-year period. So the Chinese protection status of occupation exposure has been improved in recent years. However, the average annual effective doses in some occupations, such as diagnostic radiology and coal mining, were still much higher than that of the whole world. There are still needs for further improvement and careful monitoring of occupational exposure to protect every worker from excessive occupational exposure, especially for the workers who were neglected before. (authors)

  19. Risk equivalent of exposure versus dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    This report describes a risk analysis study of low-dose irradiation and the resulting biological effects on a cell. The author describes fundamental differences between the effects of high-level exposure (HLE) and low-level exposure (LLE). He stresses that the concept of absorbed dose to an organ is not a dose but a level of effect produced by a particular number of particles. He discusses the confusion between a linear-proportional representation of dose limits and a threshold-curvilinear representation, suggesting that a LLE is a composite of both systems

  20. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  1. Patient radiation exposure and dose tracking: a perspective.

    Science.gov (United States)

    Rehani, Madan M

    2017-07-01

    Much of the emphasis on radiation protection about 2 decades ago accrued from the need for protection of radiation workers and collective doses to populations from medical exposures. With the realization that individual patient doses were rising and becoming an issue, the author had propagated the concept of a smart card for radiation exposure history of individual patients. During the last 7 years, much has happened wherein radiation exposure and the dose history of individual patients has become a reality in many countries. In addition to dealing with overarching questions, such as "Why track, what to track, and how to track?," this review elaborates on a number of points such as attitudes toward tracking, review of practices in large parts of the world, description of various elements for exposure and dose tracking, how to use the information available from tracking, achievements and stumbling blocks in implementation to date, templates for implementation of tracking at different levels of health care, the role of picture archiving and communication systems and eHealth, the role of tracking in justification and optimization of protection, comments on cumulative dose, how referrers can use this information, current provisions in international standards, and future actions.

  2. Biological Effects of Low-Dose Exposure

    CERN Document Server

    Komochkov, M M

    2000-01-01

    On the basis of the two-protection reaction model an analysis of stochastic radiobiological effects of low-dose exposure of different biological objects has been carried out. The stochastic effects are the results published in the last decade: epidemiological studies of human cancer mortality, the yield of thymocyte apoptosis of mice and different types of chromosomal aberrations. The results of the analysis show that as dependent upon the nature of biological object, spontanous effect, exposure conditions and radiation type one or another form dose - effect relationship is realized: downwards concave, near to linear and upwards concave with the effect of hormesis included. This result testifies to the incomplete conformity of studied effects of 1990 ICRP recomendations based on the linear no-threshold hypothesis about dose - effect relationship. Because of this the methodology of radiation risk estimation recomended by ICRP needs more precisian and such quantity as collective dose ought to be classified into...

  3. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  4. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  5. Time- and radiation-dose dependent changes in the plasma proteome after total body irradiation of non-human primates: Implications for biomarker selection.

    Directory of Open Access Journals (Sweden)

    Stephanie D Byrum

    Full Text Available Acute radiation syndrome (ARS is a complex multi-organ disease resulting from total body exposure to high doses of radiation. Individuals can be exposed to total body irradiation (TBI in a number of ways, including terrorist radiological weapons or nuclear accidents. In order to determine whether an individual has been exposed to high doses of radiation and needs countermeasure treatment, robust biomarkers are needed to estimate radiation exposure from biospecimens such as blood or urine. In order to identity such candidate biomarkers of radiation exposure, high-resolution proteomics was used to analyze plasma from non-human primates following whole body irradiation (Co-60 at 6.7 Gy and 7.4 Gy with a twelve day observation period. A total of 663 proteins were evaluated from the plasma proteome analysis. A panel of plasma proteins with characteristic time- and dose-dependent changes was identified. In addition to the plasma proteomics study reported here, we recently identified candidate biomarkers using urine from these same non-human primates. From the proteomic analysis of both plasma and urine, we identified ten overlapping proteins that significantly differentiate both time and dose variables. These shared plasma and urine proteins represent optimal candidate biomarkers of radiation exposure.

  6. Exposure doses to angiographers during interventional angiography

    International Nuclear Information System (INIS)

    Fukutomi, Yukimi; Yasuhara, Yoshifumi; Sugata, Shigenori; Fujii, Takashi; Kawakami, Toshiaki; Ikezoe, Junpei

    1997-01-01

    We report the exposure doses to angiographers during interventional angiography and the protective efficacy of protective aprons against X-rays in this study. The first (main) angiographer was exposed to the maximum dose of 1 μSv/min at the left chest area and lower abdominal area inside the protective apron. The second (assistant) angiographer was exposed to the maximum dose of 2 μSv/min at the left chest area and 1 μSv/min at the lower abdominal area. X-ray transmission ratio of the protective apron was 4.9 percent or less for UL25L, O percent for 0.35 mmPb and 4.3 percent or less for 0.5 mmPb. These results were lower than the dose equivalent limit based on the laws and ordinances. The protection capacities of these protective aprons proved to be sufficient. The exposure dose at the left extremity area outside the protective apron, however, was 24 times higher than at the left chest area inside. The data showed that it was not protected from scattered X-rays outside the protective apron. It is imperative to consider secondary protective material for the area outside the protective apron. Considering the risk of radiation, we need to better control exposure to angiographers. (author)

  7. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Frederic, E-mail: fredericbaumann@hotmail.com; Katzen, Barry T. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States); Carelsen, Bart [Philips HealthCare, Clinical Science Interventional X-ray (Netherlands); Diehm, Nicolas [Kantonsspital Aarau, Clinical and Interventional Angiology (Switzerland); Benenati, James F.; Peña, Constantino S. [Baptist Hospital of Miami, Miami Cardiac & Vascular Institute (MCVI) (United States)

    2015-10-15

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

  8. The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

    International Nuclear Information System (INIS)

    Baumann, Frederic; Katzen, Barry T.; Carelsen, Bart; Diehm, Nicolas; Benenati, James F.; Peña, Constantino S.

    2015-01-01

    PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter

  9. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  10. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  11. Cosmic rays exposure during aircraft flight (3). Guideline and dose evaluation

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    2007-01-01

    Radiation Council of MEXT drew up the Guideline of Cosmic Ray Exposure Control for Air Crew in 2006. The content of the Guideline and evaluation methods of dose are explained. The Guideline stated five items for Airline Company. It consists of 1) exposure dose control for air crew, 2) evaluation methods of cosmic rays exposure dose of air crew, 3) explanation and education of cosmic rays exposure for air crew, 4) reading, record and store of cosmic rays exposure dose of air crew, and 5) health control of air crew. The doses of four airlines were calculated by the Civil Aeromedical Research Institute (CARI) code and the European Program package for the Calculation of Aviation Route Doses (EPCARD) code. The difference of two codes was about 15 to 25%. Japanese Internet System for Calculation of Aviation Route Doses (JISCAED) has been developed by Japan. (S.Y.)

  12. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure, and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure, and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6, and 15 months) were given five doses (20, 60, 180, 540, and 1620 rad) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rad/day and 25 rad/min). Forty to sixty mice were used in each of the approximately 110 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replication. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the 15-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used

  13. Effect of exposure dose reduction using a compensating filter

    International Nuclear Information System (INIS)

    Katsuda, Toshizo; Nakajima, Tadashi; Kuwano, Tadao; Ueda, Kouki; Sasaki, Yasuhiro; Yoshida, Jiro

    1993-01-01

    It is empirically said that the application of the compensating filter leads to a decrease in the exposure dose of the filter-inserted area and an increase in that of the otherwise area. Using the area-dosimeter, comparison was made of exposure doses by the application of the above filter and the otherwise filter in head simple X-P, abdominal angiography and lower extremity X-P. Using the filter for head simple X-P and Mix-Dp phantom, measurement was made of the absorbed dose at the 5 cm-depth to compare the rate of decrease in absorbed dose between the above both areas. Head simple X-P gained a decrease in area dose of 29%. The absorbed dose at the 5 cm-depth in the phantom experiment showed a decrease of over 26% at the filter-inserted area, but little increase at the otherwise area. The above results indicated the interposition of the filter between the X-ray tube and the object to lead to decreases not only in the area dose but also in the patient's exposure dose. (author)

  14. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  15. Respiratory dysfunction in swine production facility workers: dose-response relationships of environmental exposures and pulmonary function.

    Science.gov (United States)

    Donham, K J; Reynolds, S J; Whitten, P; Merchant, J A; Burmeister, L; Popendorf, W J

    1995-03-01

    Human respiratory health hazards for people working in livestock confinement buildings have been recognized since 1974. However, before comprehensive control programs can be implemented, more knowledge is needed of specific hazardous substances present in the air of these buildings, and at what concentrations they are harmful. Therefore, a medical epidemiological and exposure-response study was conducted on 207 swine producers using intensive housing systems (108 farms). Dose-response relationships between pulmonary function and exposures are reported here. Positive correlations were seen between change in pulmonary function over a work period and exposure to total dust, respirable dust, ammonia, respirable endotoxin, and the interactions of age-of-producer and dust exposure and years-of-working-in-the-facility and dust exposure. Relationships between baseline pulmonary function and exposures were not strong and therefore, not pursued in this study. The correlations between exposure and response were stronger after 6 years of exposure. Multiple regression models were used to identify total dust and ammonia as the two primary environmental predictors of pulmonary function decrements over a work period. The regression models were then used to determine exposure concentrations related to pulmonary function decrements suggestive of a health hazard. Total dust concentrations > or = 2.8 mg/m3 were predictive of a work period decrement of > or = 10% in FEV1. Ammonia concentrations of > or = 7.5 ppm were predictive of a > or = 3% work period decrement in FEV1. These predictive concentrations were similar to a previous dose-response study, which suggested 2.5 mg/m3 of total dust and 7 ppm of NH3 were associated with significant work period decrements. Therefore, dust > or = 2.8 mg/m3 and ammonia > or = 7.5 ppm should be considered reasonable evidence for guidelines regarding hazardous exposure concentrations in this work environment.

  16. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    Science.gov (United States)

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  17. Thyroid doses from external gamma-exposure following the Chernobyl accident

    International Nuclear Information System (INIS)

    Tretyakevich, Sergey; Kukhta, Tatyana; Minenko, Victor; Drozdovitch, Vladimir; Luckyanov, Nickolas; Gavrilin, Yury; Khrouch, Valeri; Shinkarev, Sergey

    2008-01-01

    Full text: An increase of thyroid cancer incidence among children in Belarus has been observed after the Chernobyl accident. The main contributor to the thyroid dose was caused by 131 I intake with fresh milk in 1986. Other contributions to the thyroid dose (external gamma-exposure, short-lived iodine isotopes, internal radiocesium) were small in comparison to the dose from 131 I intakes soon after the accident. However, exposures to external radiation continued for a number of years after the accident. Thyroid doses from external gamma-exposure following the Chernobyl accident were mainly caused by gamma-exposure to 24 nuclides: 95 Zr, 95 Nb, 99 Mo, 99 mTc, 103 Ru, 103m Rh, 106 Ru, 125 Sb, 125m Te, 131m Te, 131 I, 132 Te, 132 I, 133 I, 135 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba, 140 La, 141 Ce, 144 Ce, 144 Pr, 239 Np. Data of personal interview were used to take into account the personal residence history for the time elapsed from the Chernobyl accident until the interview (10 to 15 years later). Cumulative thyroid doses caused by external gamma-exposure during the passage of the radioactive cloud and from the ground contamination following the Chernobyl accident have been reconstructed. The median thyroid dose from external gamma-exposure to ∼11,770 cohort members of an epidemiological study was estimated to be ∼6 mGy. There are ∼3,400 persons with external dose estimates that exceed 20 mGy. Exposure from radionuclides deposited on the ground was the main source of external dose. The contribution from the passing radioactive cloud to external dose was found to be negligible. (author)

  18. Overview of the use of dose constraints in medical exposures

    International Nuclear Information System (INIS)

    Tuyisenge, J. D.

    2014-01-01

    The project overviewed the use of dose constraints in medical exposure in literature. Different documents on the establishment, the development and the application of this concept are reviewed with regard to the use of medical exposure of patients, including their comforters and carers or helpers, and volunteers in biomedical research. It has been showed that the concept of Dose Constraints along with many other concepts of radiation protection is widely applied in the optimisation of exposure to radiation. These concepts include Dose Limits, Dose References levels and Guidance levels among others. With regard to medical exposure of patients, it is not appropriate to apply dose limits or dose constraints, because such limits would often do more harm than good as far as benefits from such an exposure is concerned. Dose constraints do not apply with regard to any exposure of patient for his/her diagnostic or therapeutic purposes. With regard to patient comforters, carers or helpers, and volunteers in biomedical research, the benefits of such an exposure are not direct to the exposed individuals; therefore dose constraints will be appropriately applied. From the beginning of the establishment of Dose Constraints as a concept in radiation protection, the International Commission of Radiological Protection (ICRP) has published a number of documents that provide detailed application related to radiological protection and safety in the medical applications of ionising radiation. Each of these publications addresses a specific topic defined by the type of radiation source and the medical discipline in which the source is applied. This is done in the intention of communicating directly to the relevant medical radiation users, competent radiation authorities and health related institutions concerns with radiation protection and safe use of radiation sources in medical applications. This project provides an overview of such publications and related documents. (author)

  19. Calculating gamma dose factors for hot particle exposures

    International Nuclear Information System (INIS)

    Murphy, P.

    1990-01-01

    For hot particle exposures to the skin, the beta component of radiation delivers the majority of the dose. However, in order to fully demonstrate regulatory compliance, licenses must ordinarily provide reasonable bases for assuming that both the gamma component of the skin dose and the whole body doses are negligible. While beta dose factors are commonly available in the literature, gamma dose factors are not. This paper describes in detail a method by which gamma skin dose factors may be calculated using the Specific Gamma-ray Constant, even if the particle is not located directly on the skin. Two common hot particle exposure geometries are considered: first, a single square centimeter of skin lying at density thickness of 7 mg/cm 2 and then at 1000 mg/cm 2 . A table provides example gamma dose factors for a number of isotopes encountered at power reactors

  20. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  1. Monitoring of radiation exposure and registration of doses

    International Nuclear Information System (INIS)

    1996-01-01

    The guide defines the concepts relevant to the monitoring of radiation exposure and working conditions and provides guidelines for determining the necessity of monitoring and subsequently organizing it. In addition, instructions are given for reporting doses to the Dose Register of the Finnish Centre for Radiation and Nuclear Safety (STUK). Also the procedures are described for situations leading to exceptional exposures. (10 refs., 1 tab.)

  2. Exposure of luminous marine bacteria to low-dose gamma-radiation.

    Science.gov (United States)

    Kudryasheva, N S; Petrova, A S; Dementyev, D V; Bondar, A A

    2017-04-01

    The study addresses biological effects of low-dose gamma-radiation. Radioactive 137 Cs-containing particles were used as model sources of gamma-radiation. Luminous marine bacterium Photobacterium phosphoreum was used as a bioassay with the bioluminescent intensity as the physiological parameter tested. To investigate the sensitivity of the bacteria to the low-dose gamma-radiation exposure (≤250 mGy), the irradiation conditions were varied as follows: bioluminescence intensity was measured at 5, 10, and 20°С for 175, 100, and 47 h, respectively, at different dose rates (up to 4100 μGy/h). There was no noticeable effect of gamma-radiation at 5 and 10°С, while the 20°С exposure revealed authentic bioluminescence inhibition. The 20°С results of gamma-radiation exposure were compared to those for low-dose alpha- and beta-radiation exposures studied previously under comparable experimental conditions. In contrast to ionizing radiation of alpha and beta types, gamma-emission did not initiate bacterial bioluminescence activation (adaptive response). As with alpha- and beta-radiation, gamma-emission did not demonstrate monotonic dose-effect dependencies; the bioluminescence inhibition efficiency was found to be related to the exposure time, while no dose rate dependence was found. The sequence analysis of 16S ribosomal RNA gene did not reveal a mutagenic effect of low-dose gamma radiation. The exposure time that caused 50% bioluminescence inhibition was suggested as a test parameter for radiotoxicity evaluation under conditions of chronic low-dose gamma irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Assessment of exposure dose to workers in virtual decommissioning environments

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok

    2014-01-01

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning

  4. Assessment of exposure dose to workers in virtual decommissioning environments

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, KwanSeong; Moon, JeiKwon; Choi, ByungSeon; Hyun, Dongjun; Lee, Jonghwan; Kim, Ikjune; Kim, GeunHo; Seo, JaeSeok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    This paper is intended to suggest the method analyze and assess the exposure dose to workers in virtual decommissioning environments. To simulate a lot of decommissioning scenarios, decommissioning environments were designed in virtual reality. To simulate and assess the exposure dose to workers, human model also was designed in virtual environments. These virtual decommissioning environments made it possible to real-time simulate and assess the exposure dose to workers. This work was to be able to simulate scenarios of decommissioning so that exposure dose to workers could be measured and assessed. To establish the plan of exposure dose to workers during decommissioning of nuclear facilities before decommissioning activities are accomplished, the method of simulation assessment was developed in virtual radiological environments. But this work was developed as a tool of simulation for single subject mode. Afterwards, the simulation environment for multi-subjects mode will be upgraded by simultaneous modules with networking environments. Then the much more practical method will be developed by changing number of workers and duration of time under any circumstances of decommissioning.

  5. Radiation exposure and dose to small mammals in radon-rich soils

    International Nuclear Information System (INIS)

    Macdonald, C.R.; Laverock, M.J.

    1998-01-01

    Protection of the environment from radionuclide releases requires knowledge of the normal background levels of radiation exposure in the exposed biotic community and an estimate of the detriment caused by additional exposure. This study modeled the background exposure and dose to the lungs of small burrowing mammals from 222 Rn in artificial burrows in radon-rich soils at a site in southeastern Manitoba. E-PERM chambers used to measure 222 Rn in soil showed good reproducibility of measurement, with an average coefficient of variance (CV) of about 10%. Geometric mean (GM) 222 Rn concentrations at nine randomly selected sites ranged from 5,490 Bq/m 3 (GSD = 1.57, n = 7) to 41,000 Bq/m 3 (GSD = 1.02, n = 5). Long-term monitoring of 222 Rn concentrations in artificial burrows showed large variation within and between burrows and did not show consistent variation with season, orientation of the burrow opening, or levels of 226 Ra in the soil. Annual GM concentrations in individual burrows ranged from 7,480 Bq/m 3 (GSD = 1.60) to 18,930 Bq/m 3 (GSD = 1.81) in burrows several meters apart. A grand GM of 9,990 Bq/m 3 (GSD = 1.81, n = 214) was measured over the site for the year. An exposure model was constructed for five small mammal species based on their respiration rates and the number of hours spent in the burrow, active or hibernating, exposed to soil gas 222 Rn, and the time spent out of the burrow exposed to atmospheric 222 Rn. A background dose of 0.9 mGy/a from atmospheric 222 Rn (40 Bq/m 3 ) was estimated for a large-bodied (80 kg), nonburrowing animal living on the soil surface. The highest exposures (mJ/a) in burrowing mammals occurred in those species with the highest respiration rates. Hibernation accounted for a small fraction of total annual exposure ( 22R n concentrations from the field studies and an equilibrium factor (F) of 0.5, doses to lung ranged from 90 mGy/a in the badger to 700 mGy/a in the pocket gopher. These doses closely correspond to those

  6. Using plutonium excretion data to predict dose from chronic and acute exposures

    International Nuclear Information System (INIS)

    Krahenbuhl, M.P.; Wilde, J.L.; Slaughter, D.M.

    2000-01-01

    Using fission track analysis (FTA) in conjunction with a composite theoretical model of the transport of plutonium (Pu) in the human body creates a new opportunity to estimate the exposure and dose to the general population due to plutonium in the environment. For the purposes of this study, data derived from FTA performed at the University of Utah's Center for Excellence in Nuclear Technology, Engineering and Research (CENTER) has been used to predict doses for two populations. Both population groups have no known history of plutonium exposures. Therefore, two exposure scenarios (acute and chronic) were assumed to provide boundaries for dose estimates. Dose predictions focus on equivalent dose to lung, liver, and skeletal systems and range from 0.01 mSv to 560 mSv as a function of organ, sample collection interval and exposure type. Additionally, these reconstructions demonstrate the sensitivity of dose calculations to time of sample collection and duration of exposure. As anticipated for a class Y particle, the predicted average equivalent tissue dose to the lungs represents the highest dose to the evaluated compartments. Furthermore, the data imply that the general population receives a dose one order of magnitude lower than a radiation worker with no history of exposure for the equivalent exposure scenario. (author)

  7. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  8. Effective dose rate coefficients for exposure to contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States); Bellamy, M.B.; Hiller, M.M.; Dewji, S.A. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Hertel, N.E. [Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, Oak Ridge, TN (United States); Georgia Institute of Technology, Atlanta, GA (United States); Manger, R. [University of California San Diego, Department of Radiation Medicine and Applied Sciences, La Jolla, CA (United States)

    2017-08-15

    The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios. (orig.)

  9. Patient radiation exposure dose evaluation of whole spine scanography due to exposure direction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam [Dept. of Bio-convergence Engineering, Graduate School of Korea University, Seoul (Korea, Republic of); Kwon, Soon Mu [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, Korea University, Seoul (Korea, Republic of)

    2015-04-15

    Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefore we need to redefine of protocol for digital radiography such as WSS, whole spine scanography, effective dose, patient exposure dose, exposure direction, protocol optimization.

  10. The relationship between doses to human body organs and exposure in a cloud of gamma emitting nuclides

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1976-10-01

    Monte Carlo computer techniques were recently developed in USA to derive the photon spectrum in a semi-infinite cloud of monoenergetic photon source of uniform concentration and the dose to human body organs was estimated computationally using further Monte Carlo techniques. These results are used here to derive the exposure to be expected from a cloud emitting monoenergetic photons at discrete energies between 0.01 and 4 MeV. The exposure contributions from scattered and unscattered photon fluxes are identified at each energy and the total exposure is related to doses in a range of human body organs. It is intended to use these values of rads per Roentgen to convert the exposures calculated by the reactor safety analysis code WEERIE and those derived from environmental measurements of known airborne discharges (e.g. 41 Ar, 85 Kr, 133 Xe) into doses to human body organs. (author)

  11. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    International Nuclear Information System (INIS)

    Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.

    1981-01-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors

  12. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  13. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6 and l5 months) were given five doses (20, 60, 180, 540, and 1620 rads) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rads/day and 25 rads/min). Forty to sixty mice were used in each of the approximately 119 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replicaton. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the l5-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used. It was also concluded that radiaton-induced neoplastic transformaton was significantly greater in mice with a known genetic sensitivity to neoplastic disease than in mammals which do not normally have a significant incidence of tumours. (author)

  14. Use of dose constraints for occupational exposure

    International Nuclear Information System (INIS)

    Kaijage, Tunu

    2015-02-01

    The use of dose constraints for occupational exposure was reviewed in this project. The role of dose constraints as used in optimization of protection of workers was described. Different issues to be considered in application of the concept and challenges associated with their implementation were also discussed. The situation where dose constraints could be misinterpreted to dose limits is also explained as the two are clearly differentiated by the International Commission of Radiological Protection (ICRP) Publication 103. Moreover, recommendations to all parties responsible for protection and safety of workers were discussed. (au)

  15. Estimation of internal exposure dose from food after the Fukushima Daiichi Nuclear Power Station disaster

    International Nuclear Information System (INIS)

    Takizawa, Mari; Yoshizawa, Nobuaki; Kawai, Masaki; Miyatake, Hirokazu; Hirakawa, Sachiko; Murakami, Kana; Sato, Osamu; Takagi, Shunji; Suzuki, Gen

    2016-01-01

    In order to estimate the internal exposure dose from food due to the Fukushima Daiichi Nuclear Power Station accident, total diet study (TDS) has been carried out. TDS is a method for estimating how much of certain chemicals people intake in the normal diet. A wide range of food products are chosen as targets, and the increase or decrease of chemicals depending on processing or cooking is taken into account. This paper glanced at the transition of TDS survey results, and with a focus on the survey results of the market basket (MB) system, which is one of the TDS techniques, it examined a decrease in the committed effective dose per year of radioactive cesium. Although the values of internal exposure dose from food in Fukushima Prefecture and surrounding prefectures are even now in a relatively high tendency compared with those in the distant regions, the difference has been narrowing. According to the attenuation prediction of internal exposure dose in each region of Fukushima Prefecture, the values after 5 years from the accident will be lower than the measured value on the food in market that has been investigated during 1989 and 2005. In addition, the internal exposure dose that was the survey results based on MB system in September - October 2014 was 0.0007 to 0.0022 mSv/year. These values are very small at 1% or less of the upper limit dose of 1 mSv/year as the setting basis of current reference value in Japan. (A.O.)

  16. The minimal melanogenesis dose/minimal erythema dose ratio declines with increasing skin pigmentation using solar simulator and narrowband ultraviolet B exposure

    DEFF Research Database (Denmark)

    Ravnbak, Mette H; Philipsen, Peter A; Wulf, Hans Christian

    2010-01-01

    To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure.......To investigate the relation between pre-exposure skin pigmentation and the minimal melanogenesis dose (MMD)/minimal erythema dose (MED) ratio after a single narrowband ultraviolet B (nUVB) and solar simulator (Solar) exposure....

  17. Advanced Computational Approaches for Characterizing Stochastic Cellular Responses to Low Dose, Low Dose Rate Exposures

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Bobby, R., Ph.D.

    2003-06-27

    -LET radiation). Such phantom risks also may arise from risk assessments conducted for combined exposure to low- and high-LET radiations when based on the LNT or other models that exclude RR < 1. Our results for high-LET radiation are consistent with the LNT hypothesis but only where there is no additional low-LET contribution (e.g., gamma rays) to the total dose. For high-LET neutron sources, gamma rays arise (especially in vivo) for large mammals such as humans from neutron interactions with tissue. The gamma rays might provide some protection from low-dose-related stochastic effects via inducing the protective bystander apoptosis effect that is considered to contribute to tissue cleansing via removal of problematic cells.

  18. Northern Marshall Islands radiological survey: terrestrial food chain and total doses

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Conrado, C.A.; Stuart, M.L.; Stoker, C.E.

    1982-01-01

    A radiological survey was conducted from September through November of 1978 to assess the concentrations of persistent manmade radionuclides in the terrestrial and marine environments of 11 atolls and 2 islands in the Northern Marshall Islands. The survey consisted mainly of an aerial radiological reconnaissance to map the external gamma-ray exposure rates over the islands of each atoll. The logistical support for the entire survey was designed to accommodate this operation. As a secondary phase of the survey, shore parties collected appropriate terrestrial and marine samples to assess the radiological dose from pertinent food chains to those individuals residing on the atolls, who may in the future reside on some of the presently uninhabited atolls, or who collect food from these atolls. Over 5000 terrestrial and marine samples were collected for radionuclide analysis from 76 different islands. Soils, vegetation, indigenous animals, and cistern water and groundwater were collected from the islands. Reef and pelagic fish, clams, lagoon water, and sediments were obtained from the lagoons. The concentration data for 90 Sr, 137 Cs, 238 Pu, 239 240 Pu, and 241 Am in terrestrial food crops, fowl, and animals collected at the atolls or islands are summarized. An assessment of the total dose from the major exposure pathways including external gamma, terrestrial food chain including food products and drinking water, marine food chain, and inhalation is provided. Radiological doses at each atoll or island are calculated from the average radionuclide concentrations in the terrestrial foods, marine foods, etc. assuming the average daily intake for each food item

  19. Double Dose: High Family Conflict Enhances the Effect of Media Violence Exposure on Adolescents’ Aggression

    Directory of Open Access Journals (Sweden)

    Patti M. Valkenburg

    2013-07-01

    Full Text Available We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conflict families. A total of 499 adolescents (aged 10 to 14, 48% girls participated in a two-wave longitudinal survey (4-month interval. Survey questions assessed their exposure to violence on television and in electronic games, family conflict, and aggressive behavior. Analyses revealed a significant interaction between media violence and family conflict. In families with higher conflict, higher media violence exposure was related to increased subsequent aggression. This study is the first to show a double dose effect of media violence and family conflict on adolescents’ aggression. These findings underscore the important role of the family in shaping the effects of adolescents’ media use on their social development.

  20. Monitoring of radiation exposure and registration of doses

    International Nuclear Information System (INIS)

    1993-01-01

    The Section 32 of the Finnish Radiation Act (592/91) defines the requirements to be applied to the monitoring of the radiation exposure and working conditions in Finland. The concepts relevant to the monitoring and guidelines for determining the necessity of the monitoring as well as its organizing are given in the guide. Instructions for reporting doses to the Dose Register of the Finnish Centre for Radiation and Nuclear Safety (STUK) are given, also procedures for situations leading to exceptional exposures are described. (9 refs.)

  1. Feasibility study on an integrated AEC-grid device for the optimization of image quality and exposure dose in mammography

    Science.gov (United States)

    Kim, Kyo-Tae; Yun, Ryang-Young; Han, Moo-Jae; Heo, Ye-Ji; Song, Yong-Keun; Heo, Sung-Wook; Oh, Kyeong-Min; Park, Sung-Kwang

    2017-10-01

    Currently, in the radiation diagnosis field, mammography is used for the early detection of breast cancer. In addition, studies are being conducted on a grid to produce high-quality images. Although the grid ratio of the grid, which affects the scattering removal rate, must be increased to improve image quality, it increases the total exposure dose. While the use of automatic exposure control is recommended to minimize this problem, existing mammography equipment, unlike general radiography equipment, is mounted on the back of a detector. Therefore, the device is greatly affected by the detector and supporting device, and it is difficult to control the exposure dose. Accordingly, in this research, an integrated AEC-grid device that simultaneously performs AEC and grid functions was used to minimize the unnecessary exposure dose while removing scattering, thereby realizing superior image quality.

  2. Biological effects of low-dose ionizing radiation exposure

    International Nuclear Information System (INIS)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst

    2009-01-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  3. Prenatal radiation exposure. Dose calculation

    International Nuclear Information System (INIS)

    Scharwaechter, C.; Schwartz, C.A.; Haage, P.; Roeser, A.

    2015-01-01

    The unborn child requires special protection. In this context, the indication for an X-ray examination is to be checked critically. If thereupon radiation of the lower abdomen including the uterus cannot be avoided, the examination should be postponed until the end of pregnancy or alternative examination techniques should be considered. Under certain circumstances, either accidental or in unavoidable cases after a thorough risk assessment, radiation exposure of the unborn may take place. In some of these cases an expert radiation hygiene consultation may be required. This consultation should comprise the expected risks for the unborn while not perturbing the mother or the involved medical staff. For the risk assessment in case of an in-utero X-ray exposition deterministic damages with a defined threshold dose are distinguished from stochastic damages without a definable threshold dose. The occurrence of deterministic damages depends on the dose and the developmental stage of the unborn at the time of radiation. To calculate the risks of an in-utero radiation exposure a three-stage concept is commonly applied. Depending on the amount of radiation, the radiation dose is either estimated, roughly calculated using standard tables or, in critical cases, accurately calculated based on the individual event. The complexity of the calculation thereby increases from stage to stage. An estimation based on stage one is easily feasible whereas calculations based on stages two and especially three are more complex and often necessitate execution by specialists. This article demonstrates in detail the risks for the unborn child pertaining to its developmental phase and explains the three-stage concept as an evaluation scheme. It should be noted, that all risk estimations are subject to considerable uncertainties.

  4. The effects of dose rate in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Bodenberger, U.; Holler, E.; Thierfelder, S.; Eckstein, R.

    1986-01-01

    In summary the studies in dogs show that the dose rate or exposure time has a great impact on survival of acute radiation syndromes. In contrast the inactivation of colony forming hemopoietic precursors is less influenced by the dose rate. The potential of hemopoietic recovery is determined by the survival of hemopoietic precursor cells. Therefore in patients with a suspected whole body exposure of more than 1.50 Gy, bacterial and fungal decontamination and reverse isolation in a sterile environment has to be started immediately. Human patients treated with about 10 Gy of TBI frequently developed nausea, elevated temperatures and swelling of the parotic glands at the first and second day. The extent of these changes varies from patient to patient. The temperature is rarely elevated above 38.5 0 C. The swelling of parotics and the nausea subside within 48 hours. The presence of such systemic symptoms may suggest the exposure to a lethal dose of radiation. The disappearance of immature red cells, i.e. reticulocytes, and bandforms of granulocytes within the first 5 days supports this suggestion. HLA typing of the victim and his family should be performed as soon as possible after the accident. An HLA-identical sibling would be a suitable bone marrow donor. Unlike therapeutic TBI accidental exposures bring about uncertainties in the calculation of dose, dose distribution and dose rate. Early after irradiation biological changes are extremely variable. Both biological and physical data have to be considered, when microbiological decontamination, reverse isolation and transplantation of bone marrow are to be decided upon. Obviously these intensive therapeutic efforts are limited to a small number of victims. (orig.)

  5. Exposure to Low-Dose X-Ray Radiation Alters Bone Progenitor Cells and Bone Microarchitecture.

    Science.gov (United States)

    Lima, Florence; Swift, Joshua M; Greene, Elisabeth S; Allen, Matthew R; Cunningham, David A; Braby, Leslie A; Bloomfield, Susan A

    2017-10-01

    Exposure to high-dose ionizing radiation during medical treatment exerts well-documented deleterious effects on bone health, reducing bone density and contributing to bone growth retardation in young patients and spontaneous fracture in postmenopausal women. However, the majority of human radiation exposures occur in a much lower dose range than that used in the radiation oncology clinic. Furthermore, very few studies have examined the effects of low-dose ionizing radiation on bone integrity and results have been inconsistent. In this study, mice were irradiated with a total-body dose of 0.17, 0.5 or 1 Gy to quantify the early (day 3 postirradiation) and delayed (day 21 postirradiation) effects of radiation on bone microarchitecture and bone marrow stromal cells (BMSCs). Female BALBc mice (4 months old) were divided into four groups: irradiated (0.17, 0.5 and 1 Gy) and sham-irradiated controls (0 Gy). Micro-computed tomography analysis of distal femur trabecular bone from animals at day 21 after exposure to 1 Gy of X-ray radiation revealed a 21% smaller bone volume (BV/TV), 22% decrease in trabecular numbers (Tb.N) and 9% greater trabecular separation (Tb.Sp) compared to sham-irradiated controls (P X-rays, whereas osteoclastogenesis was enhanced. A better understanding of the effects of radiation on osteoprogenitor cell populations could lead to more effective therapeutic interventions that protect bone integrity for individuals exposed to low-dose ionizing radiation.

  6. Dose conversion of radon exposure according to new epidemiological findings

    International Nuclear Information System (INIS)

    Tomasek, L.; Rogel, A.; Laurier, D.; Tirmarche, M.

    2008-01-01

    In 1993, ICRP-65 recommended that dose conversion of radon exposure should be based on the comparison of detriments between radon exposure and effective dose. The lifetime detriment from the radon exposure was projected according to the epidemiological studies of uranium miners then available. The projection model (GSF) was multiplicative with temporal and age-at-exposure modification. Since 1993, new studies of uranium miners have appeared and many original studies were updated. In addition, projections of the risk have been improved by including further modifying factors as for instance in BEIR VI. New analyses were completed in the Czech and French studies of uranium miners with accurate estimates of exposures based on extensive radon measurements. The resulting estimates of excess absolute lifetime risk per unit exposure in working level months (WLM) from these models lead to dose conversion of 10 mSv WLM -1 for the BEIR VI model and 8 mSv WLM -1 for the joint Czech-French model in contrast to the conversion of 5 mSv WLM -1 for the GSF model. (authors)

  7. Individual dose monitoring of occupational exposure in nuclear industry system (1991-2000)

    International Nuclear Information System (INIS)

    Yang Lianzhen; Ma Jizeng; Li Taosheng

    2005-01-01

    The summary and main results of individual dose monitoring (1990-2000) from occupational exposure in China Nuclear Industry System are presented in this paper. During ten years, the external collective effective dose to workers in seven plants (not uranium mines and processing mills) and institutes is 98.48 person ·Sv, the per capita effective dose is 1.97 mSv. The general situation for individual dose monitoring from internal exposure is also introduced. The annual average committed effective dose is less than 5.0 mSv. The individual dose monitoring results (1991-1992) for occupational exposure from Uranium mines and processing mills are depicted. In the end, the individual dose monitoring data in nuclear industry system are preliminarily analysed. (authors)

  8. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  9. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  10. Exposures at low doses and biological effects of ionizing radiations

    International Nuclear Information System (INIS)

    Masse, R.

    2000-01-01

    Everyone is exposed to radiation from natural, man-made and medical sources, and world-wide average annual exposure can be set at about 3.5 mSv. Exposure to natural sources is characterised by very large fluctuations, not excluding a range covering two orders of magnitude. Millions of inhabitants are continuously exposed to external doses as high as 10 mSv per year, delivered at low dose rates, very few workers are exposed above the legal limit of 50 mSv/year, and referring to accidental exposures, only 5% of the 116 000 people evacuated following the Chernobyl disaster encountered doses above 100 mSv. Epidemiological survey of accidentally, occupationally or medically exposed groups have revealed radio-induced cancers, mostly following high dose-rate exposure levels, only above 100 mSv. Risk coefficients were derived from these studies and projected into linear models of risk (linear non-threshold hypothesis: LNT), for the purpose of risk management following exposures at low doses and low dose-rates. The legitimacy of this approach has been questioned, by the Academy of sciences and the Academy of medicine in France, arguing: that LNT was not supported by Hiroshima and Nagasaki studies when neutron dose was revisited; that linear modelling failed to explain why so many site-related cancers were obviously nonlinearly related to the dose, and especially when theory predicted they ought to be; that no evidence could be found of radio-induced cancers related to natural exposures or to low exposures at the work place; and that no evidence of genetic disease could be shown from any of the exposed groups. Arguments were provided from cellular and molecular biology helping to solve this issue, all resulting in dismissing the LNT hypothesis. These arguments included: different mechanisms of DNA repair at high and low dose rate; influence of inducible stress responses modifying mutagenesis and lethality; bystander effects allowing it to be considered that individual

  11. Low-dose neutron dose response of zebrafish embryos obtained from the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility

    International Nuclear Information System (INIS)

    Ng, C.Y.P.; Kong, E.Y.; Konishi, T.; Kobayashi, A.; Suya, N.; Cheng, S.H.; Yu, K.N.

    2015-01-01

    The dose response of embryos of the zebrafish, Danio rerio, irradiated at 5 h post fertilization (hpf) by 2-MeV neutrons with ≤100 mGy was determined. The neutron irradiations were made at the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) facility in the National Institute of Radiological Sciences (NIRS), Chiba, Japan. A total of 10 neutron doses ranging from 0.6 to 100 mGy were employed (with a gamma-ray contribution of 14% to the total dose), and the biological effects were studied through quantification of apoptosis at 25 hpf. The responses for neutron doses of 10, 20, 25, and 50 mGy approximately fitted on a straight line, while those for neutron doses of 0.6, 1 and 2.5 mGy exhibited neutron hormetic effects. As such, hormetic responses were generically developed by different kinds of ionizing radiations with different linear energy transfer (LET) values. The responses for neutron doses of 70 and 100 mGy were significantly below the lower 95% confidence band of the best-fit line, which strongly suggested the presence of gamma-ray hormesis. - Highlights: • Neutron dose response was determined for embryos of the zebrafish, Danio rerio. • Neutron doses of 0.6, 1 and 2.5 mGy led to neutron hormetic effects. • Neutron doses of 70 and 100 mGy accompanied by gamma rays led to gamma-ray hormesis

  12. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  13. Effects of exposure imprecision on estimation of the benchmark dose

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Esben; Keiding, Niels; Grandjean, Philippe

    2004-01-01

    In regression analysis failure to adjust for imprecision in the exposure variable is likely to lead to underestimation of the exposure effect. However, the consequences of exposure error for determination of safe doses of toxic substances have so far not received much attention. The benchmark...... approach is one of the most widely used methods for development of exposure limits. An important advantage of this approach is that it can be applied to observational data. However, in this type of data, exposure markers are seldom measured without error. It is shown that, if the exposure error is ignored......, then the benchmark approach produces results that are biased toward higher and less protective levels. It is therefore important to take exposure measurement error into account when calculating benchmark doses. Methods that allow this adjustment are described and illustrated in data from an epidemiological study...

  14. Plants as warning signal for exposure to low dose radiation

    International Nuclear Information System (INIS)

    Rusli Ibrahim; Norhafiz Talib

    2012-01-01

    The stamen-hair system of Tradescantia for flower colour has proven to be one of the most suitable materials to study the frequency of mutations induced by low doses of various ionizing radiations and chemical mutagens. The system has also been used successfully for detecting mutagenic synergisms among chemical mutagens and ionizing radiations as well as for studying the variations of spontaneous mutation frequency. In this study of radiobiology, the main objective is to observe somatic mutation (occurrence of pink cells from blue cells) induced on stamen hairs of five Tradescantia sp. available in Malaysia after exposure to low doses of chronic gamma irradiation using Gamma Green House. Pink cells appeared only on Tradescantia Pallida Purpurea stamen hairs after 13 days of exposure to irradiation with different doses of gamma rays. The highest number of stamens with pink cells was recorded from flowers irradiated with the highest dose of 6.37 Gy with 0.07 Gy/ h of dose rate. The lowest number of stamens with pink cells was recorded with an average of 0.57, irradiated with the lowest dose of 0.91 Gy with 0.01 Gy/ h of dose rate. There were no pink cells observed on Tradescantia Spathaceae Discolor after exposure to different doses of gamma rays. Similar negative results were observed for the control experiments. The principal cells in this assay are the mitotic stamen hair cells developing in the young flower buds. After exposure to radiation, the heterozygous dominant blue character of the stamen hair cell is prevented, resulting in the appearance of the recessive pink color. Furthermore, no pink cell appears on all species of Tradescantia spathaceae after irradiated with different doses of gamma rays. The sensitivity of the Tradescantia has been used widely and has demonstrated the relation between radiation dose and frequency of mutation observed at low doses which can contribute to the effects of low doses and their consequences for human health. This system

  15. Trends in x-ray photography and patient exposure dose

    International Nuclear Information System (INIS)

    Orito, Takeo; Sanada, Shigeru; Maekawa, Ryuichi; Koshida, Kichiro; Hiraki, Tatsunosuke

    1980-01-01

    The exposure doses of patients in X-ray photography are influenced by such technological factors as X-ray tube voltage, filter, sensitizing screen, film and grid. Survey by questionnnaire was made previously in 1973 on the above factors. The trends five years after were surveyed similarly, in connection with the exposure doses of patients. Questionnaires were sent to 200 radiation technicians, and 121 (60.5%) answered the survey in March, 1979. The results in the cases of simple X-ray photography and obstetric, infant and breast X-ray photographings are described. X-ray tube voltage is generally on the increase. In the sensitizing screens, exposure doses are fairly decreased due to the use of improved intensifying screen (LT-II). In the grid, the ratio 8 : 1 is used more than 5 : 1. In the usage of additional filters and in the distance of photography, improvements are desired. (J.P.N.)

  16. Dose budget for exposure control

    International Nuclear Information System (INIS)

    Nair, P.S.

    1999-01-01

    Dose budget is an important management tool to effectively control the collective dose incurred in a nuclear facility. The budget represents a set of yardsticks or guidelines for use in controlling the internal activities, involving radiation exposure in the organisation. The management, through budget can evaluate the radiation protection performance at every level of the organisation where a number of independent functional groups work on routine and non-routine jobs. The discrepancy between the plan and the actual performance is high lighted through the budgets. The organisation may have to change the course of its operation in a particular area or revise its plan with due focus on appropriate protective measures. (author)

  17. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  18. Statistics and assessment of individual dose from occupational exposure in nuclear industry (1985-1990)

    International Nuclear Information System (INIS)

    Wang Yunfang; Yang Lianzhen

    1993-01-01

    The summary and main results of individual dose monitoring (1985-1990) from occupational exposure in nuclear industry are presented. The statistical results show that the annual collective dose equivalent from external exposure to workers in six plants and institutes in 1985-1990 are 29.88, 26.95, 19.16, 14.26, 9.08 and 9.22 man · Sv, respectively. The annual average dose equivalent are 4.98, 4.66, 3.65, 2.79, 2.40 and 2,27 mSv, respectively. The general situation for individual dose monitoring from internal exposure is briefly introduced. The internal exposure dose from uranium, plutonium and tritium in some facilities are given. The annual average committed effective dose equivalent are less than 5.0 mSv. The individual dose monitoring results for occupational exposure from uranium mining are depicted. The individual dose monitoring data are analysed preliminarily

  19. Exposure doses received from a large scale fire in the restricted area

    International Nuclear Information System (INIS)

    Kawakami, Hiroto; Yamada, Norikazu; Shimomura, Masanori; Ichiki, Takahiko; Kajimoto, Mitsuhiro; Kasahara, Fumio; Tanemura, Munenori; Tsuchino, Susumu; Okubo, Atsushi

    2012-02-01

    At the request of the Local Nuclear Emergency Response Headquarters established in Fukushima Prefecture, Japan Nuclear Energy Safety Organization (JNES) has estimated exposure doses of a fireman and the public during a large scale fire in the restricted area. Data on the contamination of the area were compiled and contaminants deposited on combustible materials in forests were investigated. Estimated doses during a fire vary widely due to the uncertainties and variations in assessment methods, location of the fire (radioactivity in the area, amounts of combustible substance and so on), the scale of the fire (the area of fire spreading), weather conditions (wind direction, wind speed, turbulence type and so on), and the distances of the fireman and the public from the fire. In this reports, effects of these factors were integrated as fire-effect indexes. One can easily obtain exposure doses by multiplying these indexes to the results in each of the assessing conditions. In the severer conditions such as 20 hs of fire spreading area, a contaminant concentration of 6 MBq/m"2 in the area, external dose of a fireman working in the highest air contaminated zone in the vicinity of the fire for 1 hour is estimated to be 50 μSv. If he does not wear a front mask, the internal committed dose is estimated to be 430 μSv. Sum of these doses can rise up to 480 μSv. External and internal doses of the public at the severest location in the distance of 2 km from the fire for 1 hour is estimated to be 5 μSv and 45 μSv respectively, and the sum of these doses is 50 μSv. In the stable conditions where a plume of fire can reach to a longer distance without dispersion, external and internal doses of the public at the 20 km distance from the fire for 1 hour are estimated to be 0.5 μSv and 4.5 μSv respectively, and the sum of them is less than 5 μSv. Though the total exposure dose will not exceed 1 mSv even if the fire lingers for some days, monitoring of radiation is important in

  20. Doses of emergency exposure to the USSR Navy personnel

    International Nuclear Information System (INIS)

    Skaletskiy, Yuriy

    2013-01-01

    Radiological consequences of the Soviet Navy accidents are significant and the number of acute radiation syndrome (ARS) cases is comparable to the number of ARS cases to Chernobyl catastrophe witness and clean-up workers in 1986. Results of a careful clinical-epidemiological examination of the personnel overexposed in the Navy accidents not only have value of radiobiology and radiation medicine specialists but can become a basis for the evaluation of the effectiveness of social protection strategy for the Chernobyl catastrophe clean-up workers. The officially registered exposure doses to persons affected by the Navy radiation accidents in some cases differ from the actual ones due to the imperfections of radiation monitoring facilities at the time of accidents. There was a tendency of clinical overstatement of the exposure doses resulting in diagnosis of 1st degree of ARS to persons who received external doses lower than 0.75. In some cases even 0.2 Gy was overstated as ARS severity for 2nd, 3rd, and 4th degrees. Exposure doses to the affected by the Navy accidents and their ARS severity degrees were evaluated with rather good accuracy. The use of modern method and approaches to the retrospective dose assessment allows more accurate evaluation of the submarine personnel exposure doses as well as verification of every ARS case, thus creating a necessary dosimetric basis for the organization of a correct radiation epidemiological investigation for persons of this contingent. Regretfully, tragic experience of nuclear power plants operation at the Navy vessels was not subject to analysis of specialists in order to improve nuclear safety, radiation protection, and emergency response organization in order to nuclear energy use in the USSR. (N.T.)

  1. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    Energy Technology Data Exchange (ETDEWEB)

    Zankl, M. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Drexler, G. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Petoussi-Henss, N. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Saito, K. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body`s longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called `remainder`. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  2. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    International Nuclear Information System (INIS)

    Zankl, M.

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body's longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called 'remainder'. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  3. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  4. Dose exposure work planning using DMU kinematics tools

    International Nuclear Information System (INIS)

    Rosli Darmawan

    2010-01-01

    The study on the possibility of using DMU Kinematics module in CAE tools for dose exposure work planning was carried out. A case scenario was created using 3D CAD software and transferred to DMU Kinematics module in CAE software. A work plan was created using DMU Kinematics tools and animated to simulate a real time scenario. Data on the phantom position against the radioactive source was collected by activating positioning sensors in the module. The data was used to estimate dose rate exposure for the phantom. The results can be used to plan the safest and optimum procedures in carrying out the radiation related task. (author)

  5. Low-dose cadmium exposure exacerbates polyhexamethylene guanidine-induced lung fibrosis in mice.

    Science.gov (United States)

    Kim, Min-Seok; Kim, Sung-Hwan; Jeon, Doin; Kim, Hyeon-Young; Han, Jin-Young; Kim, Bumseok; Lee, Kyuhong

    2018-01-01

    Cadmium (Cd) is a toxic metal present in tobacco smoke, air, food, and water. Inhalation is an important route of Cd exposure, and lungs are one of the main target organs for metal-induced toxicity. Cd inhalation is associated with an increased risk of pulmonary diseases. The present study aimed to assess the effects of repeated exposure to low-dose Cd in a mouse model of polyhexamethylene guanidine (PHMG)-induced lung fibrosis. Mice were grouped into the following groups: vehicle control (VC), PHMG, cadmium chloride (CdCl 2 ), and PHMG + CdCl 2 . Animals in the PHMG group exhibited increased numbers of total cells and inflammatory cells in the bronchoalveolar lavage fluid (BALF) accompanied by inflammation and fibrosis in lung tissues. These parameters were exacerbated in mice in the PHMG + CdCl 2 group. In contrast, mice in the CdCl 2 group alone displayed only minimal inflammation in pulmonary tissue. Expression of inflammatory cytokines and fibrogenic mediators was significantly elevated in lungs of mice in the PHMG group compared with that VC. Further, expression of these cytokines and mediators was enhanced in pulmonary tissue in mice administered PHMG + CdCl 2 . Data demonstrate that repeated exposure to low-dose Cd may enhance the development of PHMG-induced pulmonary fibrosis.

  6. AXAIR: A Computer Code for SAR Assessment of Plume-Exposure Doses from Potential Process-Accident Releases to Atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Pillinger, W.L.

    2001-05-17

    This report describes the AXAIR computer code which is available to terminal users for evaluating the doses to man from exposure to the atmospheric plume from postulated stack or building-vent releases at the Savannah River Plant. The emphasis herein is on documentation of the methodology only. The total-body doses evaluated are those that would be exceeded only 0.5 percent of the time based on worst-sector, worst-case meteorological probability analysis. The associated doses to other body organs are given in the dose breakdowns by radionuclide, body organ and pathway.

  7. Environmental exposure to low-doses of ionizing radiation. Effects on early nephrotoxicity in mice.

    Science.gov (United States)

    Bellés, Montserrat; Gonzalo, Sergio; Serra, Noemí; Esplugas, Roser; Arenas, Meritxell; Domingo, José Luis; Linares, Victoria

    2017-07-01

    Nuclear accidents of tremendous magnitude, such as those of Chernobyl (1986) and Fukushima (2011), mean that individuals living in the contaminated areas are potentially exposed to ionizing radiation (IR). However, the dose-response relationship for effects of low doses of radiation is not still established. The present study was aimed at investigating in mice the early effects of low-dose internal radiation exposure on the kidney. Adult male (C57BL/6J) mice were divided into three groups. Two groups received a single subcutaneous (s.c.) doses of cesium ( 137 Cs) with activities of 4000 and 8000Bq/kg bw. A third group (control group) received a single s.c. injection of 0.9% saline. To evaluate acute and subacute effects, mice (one-half of each group) were euthanized at 72h and 10 days post-exposure to 137 Cs, respectively. Urine samples were collected for biochemical analysis, including the measurement of F2-isoprostane (F2-IsoP) and kidney injury molecule-1 (KIM-1) levels. Moreover, the concentrations of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a sensitive marker of oxidative DNA damage, were measured in renal tissue. Urinary excretion of total protein significantly increased at 72h in mice exposed to Cs4000. Uric acid and lactate dehydrogenase (LDH) decreased significantly at both times post-exposure in animals exposed to Cs8000. After 72h and 10d of exposure to Cs4000, a significant increase in the γ-glutamil transferase (GGT) and N-acetyl-β-D-glucosaminidase (NAG) activities was observed. In turn, F2-IsoP levels increased -mainly in the Cs4000 group- at 72h post-exposure. Following irradiation ( 137 Cs), the highest level of KIM-1 was corresponded to the Cs4000 group at 72h. Likewise, the main DNA damage was detected in mice exposed to Cs4000, mainly at 10d after irradiation. The alterations observed in several biomarkers suggest an immediate renal damage following exposure to low doses of IR (given as 137 Cs). Further investigations are required to clarify the

  8. Estimates of radiation doses from various sources of exposure

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This chapter provides an overview of radiation doses to individuals and to the collective US population from various sources of ionizing radiation. Summary tables present doses from various sources of ionizing radiation. Summary tables present doses from occupational exposures and annual per capita doses from natural background, the healing arts, nuclear weapons, nuclear energy and consumer products. Although doses from non-ionizing radiation are not as yet readily available in a concise form, the major sources of non-ionizing radiation are listed

  9. Injury of the blood-testies barrier after low-dose-rate chronic radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Young Hoon; Bae Min Ji; Lee, Chang Geun; Yang, Kwang Mo; Jur, Kyu; Kim, Jong Sun [Dongnam Institute of Radiological and Medical Science, Busan (Korea, Republic of)

    2014-04-15

    The systemic effect of radiation increases in proportionally with the dose and dose rate. Little is known concerning the relationships between harmful effects and accumulated dose, which is derived from continuous low-dose rate radiation exposure. Recent our studies show that low-dose-rate chronic radiation exposure (3.49 mGy/h) causes adverse effects in the testis at a dose of 2 Gy (6 mGy/h). However, the mechanism of the low-dose-rate 2 Gy irradiation induced testicular injury remains unclear. The present results indicate that low-dose rate chronic radiation might affect the BTB permeability, possibly by decreasing levels of ZO-1, Occludin-1, and NPC-2. Furthermore, our results suggest that there is a risk of male infertility through BTB impairment even with low-dose-rate radiation if exposure is continuous.

  10. [Determination of total phthalates in perfume and their exposure assessment].

    Science.gov (United States)

    Zhao, Sihan; Wang, Zhengmeng; Deng, Hongxia; Duan, Jiahui; Wang, Jinyi; Liu, Shuhui

    2017-12-08

    A novel method for rapid screening of phthalates (PAEs) in perfumes was developed. The PAEs were hydrolyzed to phthalic acid (PA), and the PA in the acidified solution was extracted with tributyl phosphate (TBP) which was detected by high performance liquid chromatography-diode array detection (HPLC-DAD). Meanwhile exposure dose to PAEs was estimated by the percentage of a topically applied dose that permeates the skin. The parameters such as the concentration and volume of KOH, the volume of ethanol, hydrolysis time and temperature were employed to evaluate the hydrolysis efficiency of PAEs. The optimized hydrolysis conditions were 10 mL of 4 mol/L KOH, and 1 mL of ethanol at 80℃ for 20 min. The linear range of phthalic acid was 3-240 μmol/L with a good correlation coefficient ( R 2 =0.9991). The limits of detection (LOD) and quantification (LOQ) were 4.6 μmol/kg and 5.9 μmol/kg, respectively. The recoveries varied from 83.4% to 92.7% with relative standard deviations equal to or lower than 6.8%( n =5). A total of 35 perfume samples were determined, and the contents of total PAEs were found in the range of perfumes. The method is simple and reliable, and has a wide range of applicability. It can be used as a new choice for the detection of PAEs in perfume.

  11. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  12. Computer code for calculating personnel doses due to tritium exposures

    International Nuclear Information System (INIS)

    Graham, C.L.; Parlagreco, J.R.

    1977-01-01

    This report describes a computer code written in LLL modified Fortran IV that can be used on a CDC 7600 for calculating personnel doses due to internal exposures to tritium. The code is capable of handling various exposure situations and is also capable of detecting a large variety of data input errors that would lead to errors in the dose assessment. The critical organ is the body water

  13. Student's music exposure: Full-day personal dose measurements.

    Science.gov (United States)

    Washnik, Nilesh Jeevandas; Phillips, Susan L; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.

  14. Total dose and dose rate models for bipolar transistors in circuit simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Wix, Steven D.

    2013-05-01

    The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

  15. Estimates of Health Detriments and Tissue Weighting Factors for Hong Kong Populations from Low Dose, Low Dose Rate and Low LET Ionising Radiation Exposure

    International Nuclear Information System (INIS)

    Lee, S.K.

    1998-01-01

    The total health detriments and the tissue weighting factors for the Hong Kong populations from low dose, low dose rate and low LET ionising radiation exposure are obtained according to the methodology recommended in ICRP Publication 60. The probabilities of fatal cancers for the general (ages 0-90) and working (ages 20-64) populations due to lifetime exposure at low dose and low dose rate are 4.9 x 10 -2 Sv -1 and 3.6 x 10 -2 Sv -1 respectively, comparing with the ICRP 60 estimates of 5.0 x 10 -2 Sv -1 and 4.0 x 10 -2 Sv -1 . The corresponding total health detriments for the general and working populations are 6.9 x 10 -2 Sv -1 and 4.9 x 10 -2 Sv -1 respectively comparing with the ICRP 60 estimates of 7.3 x 10 -2 Sv -1 and 5.6 x 10 -2 Sv -1 . Tissue weighting factors for the general population are 0.01 (bone surface and skin), 0.02 (liver, oesophagus and thyroid), 0.04 (bladder and breast), 0.08 (remainder), 0.10 (stomach), 0.11 (bone marrow), 0.15 (colon), 0.19 (lung) and 0.21 (gonads) and for the working population are 0.01 (bone surface and skin), 0.03 (liver, oesophagus and thyroid), 0.04 (breast), 0.06 (remainder), 0.07 (bladder), 0.08 (colon), 0.14 (bone marrow and stomach), 0.16 (lung) and 0.20 (gonads). (author)

  16. Studies on the reference Korean and estimation of radiation exposure dose

    International Nuclear Information System (INIS)

    Kim, Y.J.; Lee, K.S.; Chun, K.J.; Kim, J.B.; Chung, G.H.; Kim, S.R.

    1982-01-01

    For the purpose of establishment of Reference Korean and estimation of internal and external exposure doses in the Reference Korean, we have surveyed reference values for Koreans such as physical standards including height, weight, and body surface area, food consumption rate of daily intake of radioactive substances and exposure dose from natural radiation. (Author)

  17. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    International Nuclear Information System (INIS)

    Chen, Y.; Yan, X.K.; Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K.

    2011-01-01

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of 60 Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of 60 Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0 -3 D 2 . Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy γ-irradiation from a supra-high dose 60 Co gamma-ray accident.

  18. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  19. What happens at very low levels of radiation exposure ? Are the low dose exposures beneficial ?

    International Nuclear Information System (INIS)

    Deniz, Dalji

    2006-01-01

    Full text: Radiation is naturally present in our environment and has been since the birth of this planet. The human population is constantly exposed to low levels of natural background radiation, primarily from environmental sources, and to higher levels from occupational sources, medical therapy, and other human-mediated events. Radiation is one of the best-investigated hazardous agents. The biological effects of ionizing radiation for radiation protection consideration are grouped into two categories: The deterministic and the stochastic ones. Deterministic radiation effects can be clinically diagnosed in the exposed individual and occur when above a certain t hreshold a n appropriately high dose is absorbed in the tissues and organs to cause the death of a large number of cells and consequently to impair tissue or organ functions early after exposure. A clinically observable biological effect (Acute Radiation Sendromes, ARS) occurs days to months after an acute radiation dose. Stochastic radiation effects are the chronic effects of radiation result from relatively low exposure levels delivered over long periods of time. These are sort of effects that might result from occupational exposure, or to the background exposure levels. Such late effects might be the development of malignant (cancerous) disease and of the hereditary consequences. These effects may be observed many years after the radiation exposure. There is a latent period between the initial radiation exposure and the development of the biological effect. For this reason, a stochastic effect is called a Linear or Zero-Threshold (LNT) Dose-Response Effect. There is a stochastic correlation between the number of cases of cancers or genetic defects developed inside a population and the dose received by the population at relatively large levels of radiation. These changes in gene activation seem to be able to modify the response of cells to subsequent radiation exposure, termed the a daptive response

  20. Study on the method or reducing the operator's exposure dose from a C-Arm system

    International Nuclear Information System (INIS)

    Kim, Ki Sik; Song, Jong Nam; Kim, Seung Ok

    2016-01-01

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment

  1. Contribution of time-activity pattern and microenvironment to black carbon (BC) inhalation exposure and potential internal dose among elementary school children

    Science.gov (United States)

    Jeong, Hyeran; Park, Donguk

    2017-09-01

    The aims of this study were to quantify the contributions of activities or microenvironments (MEs) to daily total exposure to and potential dose of black carbon (BC). Daily BC exposures (24-h) were monitored using a micro-aethalometer micoAeth AE51 with forty school-aged children living in an urban area in Korea from August 2015 to January 2016. The children's time-activity patterns and the MEs they visited were investigated by means of a time-activity diary (TAD) and follow-up interviews with the children and their parents. Potential inhaled dose was estimated by multiplying the airborne BC concentrations (μg/m3) we monitored for the time the children spent in a particular ME by the inhalation rate (IR, m3/h) for the time-activity performed. The contribution of activities and MEs to overall daily exposure to and potential dose of BC was quantified. Overall mean daily potential dose was equal to 24.1 ± 10.6 μg/day (range: 6.6-46.3 μg/day). The largest contribution to BC exposure and potential dose (51.9% and 41.7% respectively) occurred in the home thanks to the large amount of time spent there. Transportation was where children received the most intense exposure to (14.8%) and potential dose (20.2%) of BC, while it accounted for 7.6% of daily time. School on weekdays during the semester was responsible for 20.3% of exposure and 22.5% of potential dose. Contribution to BC exposure and potential dose was altered by several time-activity parameters, such as type of day (weekdays vs. weekends; school days vs. holidays), season, and gender. Traveling by motor vehicle and subway showed more elevated exposure or potential dose intensity on weekdays or school days, probably influenced by the increased surrounding traffic volumes on these days compared to on weekends or holidays. This study may be used to prioritize targets for minimizing children's exposure to BC and to indicate outcomes of BC control strategies.

  2. Particle exposure and inhaled dose during commuting in Singapore

    Science.gov (United States)

    Tan, Sok Huang; Roth, Matthias; Velasco, Erik

    2017-12-01

    Exposure concentration and inhaled dose of particles during door-to-door trips walking and using motorized transport modes (subway, bus, taxi) are evaluated along a selected route in a commercial district of Singapore. Concentrations of particles smaller than 2.5 μm in size (PM2.5), black carbon, particle-bound polycyclic aromatic hydrocarbons, number of particles, active surface area and carbon monoxide have been measured in-situ using portable instruments. Simultaneous measurements were conducted at a nearby park to capture the background concentrations. The heart rate of the participants was monitored during the measurements as a proxy of the inhalation rate used to calculate the inhaled dose of particles. All measured metrics were highest and well above background levels during walking. No significant difference was observed in the exposure concentration of PM2.5 for the three motorized transport modes, unlike for the metrics associated with ultrafine particles (UFP). The concentration of these freshly emitted particles was significantly lower on subway trips. The absence of combustion sources, use of air conditioning and screen doors at station platforms are effective measures to protect passengers' health. For other transport modes, sections of trips close to accelerating and idling vehicles, such as bus stops, traffic junctions and taxi stands, represent hotspots of particles. Reducing the waiting time at such locations will lower pollutants exposure and inhaled dose during a commute. After taking into account the effect of inhalation and travel duration when calculating dose, the health benefit of commuting by subway for this particular district of Singapore became even more evident. For example, pedestrians breathe in 2.6 and 3.2 times more PM2.5 and UFP, respectively than subway commuters. Public buses were the second best alternative. Walking emerged as the worst commuting mode in terms of particle exposure and inhaled dose.

  3. High-dose "1"3"1I-MIBG therapies in children: feasibility, patient dosimetry and radiation exposure to workers and family caregivers

    International Nuclear Information System (INIS)

    Cougnenc, Olivier; Defachelles, Anne-Sophie; Lervat, Cyril; Carpentier, Philippe; Oudoux, Aurore; Kolesnikov-Gauthier, Helene; Clisant, Stephanie

    2017-01-01

    The objective of the present multi-centric phase II study (MIITOP) was to determine the response rate, survival and toxicity of tandem infusions of "1"3"1I-meta-iodobenzylguanidine (mIBG) and topotecan in children with relapsed/refractory neuroblastoma. High-dose "1"3"1I-mIBG therapy programme requires a deal of planning, availability of hospital resources and the commitment of individuals with training and expertise in multiple disciplines. Here in the present study, procedures and the results of patient's dosimetry, as well as family and worker's exposures, were reported for the patients treated in Lille. A total of 15 children were treated with "1"3"1I-mIBG between 2009 and 2011 according to the MIITOP protocol. High activity of "1"3"1I-mIBG (444 MBq kg"-"1) was administered on Day 0. In vivo dosimetry was used to calculate a second activity, to be given on Day 21, to obtain a total whole body absorbed dose of 4 Gy. Family and worker's exposures were performed too. The injected activity by treatment was from 703 to 11470 MBq. Total whole body absorbed dose by patient ranged from 2.74 to 5.2 Gy. Concerning relatives, whole body exposure ranged from 0.018 to 2.8 mSv. The mean whole body exposure of the radio-pharmacist was 4.4 nSv MBq"-"1, and the mean exposure of fingers ranged from 0.18 to 0.24 μSv MBq"-"1 according to each finger. The mean whole body exposure was 33.6 and 20.2 μSv d"-"1 per person, for night nurses and day nurses, respectively. Exposure of doctors was less than 5 μSv d"-"1. Under strict radiation protection precautions, this study shows the feasibility of high-activity "1"3"1I-mIBG therapy in France. (authors)

  4. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  5. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  6. Low-dose-rate radiation exposure leads to testicular damage with decreases in DNMT1 and HDAC1 in the murine testis

    International Nuclear Information System (INIS)

    Gong, Eun Ji; Son, Tae Gen; Yang, Kwangmo; Heo, Kyu; Kim, Joong Sun; Shin, In Sik

    2014-01-01

    This study examined the effects of continuous low-dose-rate radiation exposure (3.49 mGy/h) of gamma rays on mice testicles. C57BL/6 mice were divided into sham and radiation groups (n = 8 each), and were exposed to either sham irradiation or 2 Gy for 21 days, 0.2 Gy for 2 days, or 0.02 Gy for 6 h of low-dose-rate irradiation. Testicular weight, seminiferous tubular diameter, and seminiferous epithelial depth were significantly decreased in the mice irradiated with 2 Gy at 1 and 9 days after exposure. Moreover, the low-dose-rate radiation exposure induced an increase in malondialdehyde levels, and a decrease in superoxide dismutase activity in the testis of mice irradiated with 2 Gy at 1 and 9 days after exposure. The sperm count and motility in the epididymis also decreased in mice irradiated with 2 Gy at 1 and 9 days after exposure, whereas there was no significant effect on the proportion of abnormal sperm. The expressions of DNA methlytransferases-1 and histone deacetylases 1 in testes irradiated with 2 Gy were significantly decreased compared with the sham group. In conclusion, the damage exerted on the testes and epididymis largely depended on the total dose of low-dose-rate radiation. (author)

  7. Comparison and dosimetry of exposure dose to the patient in dental full mouth examination

    International Nuclear Information System (INIS)

    Kohirazawa, Hideo; Shinozima, Masayasu; Tokui, Mituru

    1979-01-01

    Comparisons of exposure dose to the patient of three types of oral x-ray apparatus (Dental, Panoramix, Orthopantomograph) were made. The exposure doses to the regions of incior, molar, eye (lens), thyroid gland, cervical spine and gonad were measured using Radocon II type dosimeter, T.L.D. and head phantom. Differences of exposure dose were found in three types of oral x-ray apparatus. After then improvement of aparture and investigation of sensitive materials and filter were made. Selection of the oral x-ray apparatus should not be done by exposure dose but by need of diagnosis. (author)

  8. Exposure dose response relationships of the freshwater bivalve Hyridella australis to cadmium spiked sediments

    International Nuclear Information System (INIS)

    Marasinghe Wadige, Chamani P.M.; Maher, William A.; Taylor, Anne M.; Krikowa, Frank

    2014-01-01

    organisms, which suggests that H. australis has some tolerance to cadmium. The metallothionein like protein fraction played an important role in the sequestration and detoxification of cadmium and the amount sequestered in this fraction increased with increased cadmium exposure. The highest percentage of biologically active cadmium was associated with the lysosome + microsome and mitochondrial fractions. Cadmium concentrations in these two fractions of cadmium exposed organisms were significantly higher with respect to controls. Total antioxidant capacity decreased with increased cadmium exposure and tissue dose. Lipid peroxidation increased and lysosomal membrane stability decreased significantly with increased cadmium exposure and tissue dose. Based on exposure–dose–response analysis in this study, H. australis would be a suitable organism for assessing cadmium sediment exposure and toxicity

  9. ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    Science.gov (United States)

    Jeong, Jongtae; Ko, Nak Yul; Cho, Dong-Keun; Baik, Min Hoon; Yoon, Ki-Hoon

    2018-03-16

    Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculated the exposure dose and mass of NORM waste to be disposed in landfill site by considering the activity concentration level and exposure dose. In 2012, the Korean government promulgated an act on the safety control of NORM around living environments to protect human health and the environment. For the successful implementation of this act, we suggest a reference design for a landfill for the disposal of NORM waste. Based on this reference landfill, we estimate the maximum exposure doses and the relative impact of each pathway to exposure dose for three scenarios: a reference scenario, an ingestion pathway exclusion scenario, and a low leach rate scenario. Also, we estimate the possible quantity of NORM waste disposal into a landfill as a function of the activity concentration level of U series, Th series and 40K and two kinds of exposure dose levels, 1 and 0.3 mSv/y. The results of this study can be used to support the establishment of technical bases of the management strategy for the safe disposal of NORM waste.

  10. Total and inorganic arsenic in dietary supplements based on herbs, other botanicals and algae—a possible contributor to inorganic arsenic exposure

    DEFF Research Database (Denmark)

    Hedegaard, Rikke Susanne Vingborg; Rokkjær, Inge; Sloth, Jens Jørgen

    2013-01-01

    The content of total and inorganic arsenic was determined in 16 dietary supplements based on herbs, other botanicals and algae purchased on the Danish market. The dietary supplements originated from various regions, including Asia, Europe and USA. The contents of total and inorganic arsenic...... was determined by inductively coupled plasma mass spectrometry (ICP-MS) and anion exchange HPLC-ICP-MS, respectively, were in the range of 0.58 to 5.0 mgkg−1 and 0.03 to 3.2 mg kg−1, respectively, with a ratio between inorganic arsenic and total arsenic ranging between 5 and 100 %. Consumption of the recommended...... dose of the individual dietary supplement would lead to an exposure to inorganic arsenic within the range of 0.07 to 13 μg day−1. Such exposure from dietary supplements would in worst case constitute 62.4 % of the range of benchmark dose lower confidence limit values (BMDL01 at 0.3 to 8 μg kg bw−1 kg−1...

  11. Establishment and verification of dose-response curve of chromosomal aberrations after exposure to very high dose γ-ray

    International Nuclear Information System (INIS)

    Chen Ying; Luo Yisheng; Cao Zhenshan; Liu Xiulin

    2006-01-01

    To estimate accurately biological dose of the victims exposed to high dose, the dose-response curves of chromosome aberration induced by 6-22 Gy 60 Co γ-ray were established. Human peripheral blood in vitro was irradiated, then lymphocytes were concentrated, cultured 52h, 68h and 72h and harvested. The frequencies of dicentrics (multi-centrics) and rings were counted and compared between different culture times. The dose-response curves and equations were established, as well as verified with high dose exposure accidents. The experiment showed that the culture time should be prolonged properly after high dose exposure, and no significant differences were observed between 52-72h culture. The dose-response curve of 6-22 Gy fitted to linear-square model Y=-2.269 + 0.776D - 7.868 x 10 -3 D 2 and is reliable through verification of the accident dose estimations. In this study, the dose-response curve and equation of chromosome dic + r after 6-22 Gy high dose irradiation were established firstly, and exact dose estimation can be achieved according to it. (authors)

  12. Enrichment increases hippocampal neurogenesis independent of blood monocyte-derived microglia presence following high-dose total body irradiation.

    Science.gov (United States)

    Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana

    2017-06-01

    Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  13. Total and inorganic arsenic in fish, seafood and seaweeds--exposure assessment.

    Science.gov (United States)

    Mania, Monika; Rebeniak, Małgorzata; Szynal, Tomasz; Wojciechowska-Mazurek, Maria; Starska, Krystyna; Ledzion, Ewa; Postupolski, Jacek

    2015-01-01

    According to the European Food Safety Authority (EFSA), fish, seafood and seaweeds are foodstuffs that significantly contribute to dietary arsenic intake. With the exception of some algal species, the dominant compounds of arsenic in such food products are the less toxic organic forms. Both the Joint FAO/WHO Expert Committee on Food Additives (JECFA) and EFSA recommend that speciation studies be performed to determine the different chemical forms in which arsenic is present in food due to the differences in their toxicity. Knowing such compositions can thus enable a complete exposure assessment to be made. Determination of total and inorganic arsenic contents in fish, their products, seafood and seaweeds present on the Polish market. This was then followed by an exposure assessment of consumers to inorganic arsenic in these foodstuffs. Total and inorganic arsenic was determined in 55 samples of fish, their products, seafood as well as seaweeds available on the market. The analytical method was hydride generation atomic absorption spectrometry (HGAAS), after dry ashing of samples and reduction of arsenic to arsenic hydride using sodium borohydride. In order to isolate only the inorganic forms of arsenic prior to mineralisation, samples were subjected to concentrated HCl hydrolysis, followed by reduction with hydrobromic acid and hydrazine sulphate after which triple chloroform extractions and triple 1M HCl re-extractions were performed. Exposure of adults was estimated in relation to the Benchmark Dose Lower Confidence Limit (BMDL0.5) as set by the Joint FAO/WHO Expert Committee on Food Additives (JECFA) that resulted in a 0.5% increase in lung cancer (3.0 μg/kg body weight (b.w.) per day). Mean total arsenic content from all investigated fish samples was 0.46 mg/kg (90th percentile 0.94 mg/kg), whilst the inorganic arsenic content never exceeded the detection limit of the analytical method used (0.025 mg/kg). In fish products, mean total arsenic concentration was

  14. Effects on Ferroelectric Thin-Film Stacks and Devices for Piezoelectric MEMS Applications at Varied Total Ionizing Dose (TID)

    Science.gov (United States)

    2017-03-01

    non -linearly mobile internal interfaces, e.g. domain walls and eventual phase boundaries. Radiation exposure is expected...zirconate titanate; PZT; actuator; radiation ; gamma; total ionization dose; TID; top electrode; Pt; IrO2; polarization; PE; hysteresis; permittivity...Hayashigawa, et. al., “A 2 Mbit Radiation Hardened Stackable Ferroelectric Memory” Non - Volatile Memory Technology Symposium, NVMTS 07, Nov 10-13, 2007 Albuquerque, NM, USA

  15. Patient dose, gray level and exposure index with a computed radiography system

    Science.gov (United States)

    Silva, T. R.; Yoshimura, E. M.

    2014-02-01

    Computed radiography (CR) is gradually replacing conventional screen-film system in Brazil. To assess image quality, manufactures provide the calculation of an exposure index through the acquisition software of the CR system. The objective of this study is to verify if the CR image can be used as an evaluator of patient absorbed dose too, through a relationship between the entrance skin dose and the exposure index or the gray level values obtained in the image. The CR system used for this study (Agfa model 30-X with NX acquisition software) calculates an exposure index called Log of the Median (lgM), related to the absorbed dose to the IP. The lgM value depends on the average gray level (called Scan Average Level (SAL)) of the segmented pixel value histogram of the whole image. A Rando male phantom was used to simulate a human body (chest and head), and was irradiated with an X-ray equipment, using usual radiologic techniques for chest exams. Thermoluminescent dosimeters (LiF, TLD100) were used to evaluate entrance skin dose and exit dose. The results showed a logarithm relation between entrance dose and SAL in the image center, regardless of the beam filtration. The exposure index varies linearly with the entrance dose, but the angular coefficient is beam quality dependent. We conclude that, with an adequate calibration, the CR system can be used to evaluate the patient absorbed dose.

  16. p-MOSFET total dose dosimeter

    Science.gov (United States)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  17. Determination of the total indicative dose in drinking and mineral waters

    International Nuclear Information System (INIS)

    Flesch, K.; Schulz, H.; Knappik, R.; Koehler, M.

    2006-01-01

    In Europe and Germany administrative regulations exist for the surveillance of the total indicative dose of water supplied for human consumption. This parameter, which cannot be analyzed directly, has to be calculated using nuclide specific activity concentration and age specific dose conversion factors and consumption rates. Available calculation methods differ regarding the used radionuclides, consumption rates and whether they use age specific dose conversion factors or not. In Germany administrative guidelines for the determination of the total indicative dose are still not available. As they have analyzed a large number of waters in the past, the authors derive a praxis orientated concept for the determination of the total indicative dose which respects radiological, analytical and hydrochemical aspects as well. Finally it is suggested to handle sparkling waters in the same manner as drinking waters. (orig.)

  18. CalTOX, a multimedia total exposure model for hazardous-waste sites

    International Nuclear Information System (INIS)

    McKone, T.E.

    1993-06-01

    CalTOX has been developed as a spreadsheet model to assist in health-risk assessments that address contaminated soils and the contamination of adjacent air, surface water, sediments, and ground water. The modeling effort includes a multimedia transport and transformation model, exposure scenario models, and efforts to quantify and reduce uncertainty in multimedia, multiple-pathway exposure models. This report provides an overview of the CalTOX model components, lists the objectives of the model, describes the philosophy under which the model was developed, identifies the chemical classes for which the model can be used, and describes critical sensitivities and uncertainties. The multimedia transport and transformation model is a dynamic model that can be used to assess time-varying concentrations of contaminants introduced initially to soil layers or for contaminants released continuously to air or water. This model assists the user in examining how chemical and landscape properties impact both the ultimate route and quantity of human contact. Multimedia, multiple pathway exposure models are used in the CalTOX model to estimate average daily potential doses within a human population in the vicinity of a hazardous substances release site. The exposure models encompass twenty-three exposure pathways. The exposure assessment process consists of relating contaminant concentrations in the multimedia model compartments to contaminant concentrations in the media with which a human population has contact (personal air, tap water, foods, household dusts soils, etc.). The average daily dose is the product of the exposure concentrations in these contact media and an intake or uptake factor that relates the concentrations to the distributions of potential dose within the population

  19. Dose - response relationship between noise exposure and the risk of occupational injury

    Directory of Open Access Journals (Sweden)

    Jin-Ha Yoon

    2015-01-01

    Full Text Available Many workers worldwide experience fatality and disability caused by occupational injuries. This study examined the relationship between noise exposure and occupational injuries at factories in Korea. A total of 1790 factories located in northern Gyeonggi Province, Korea was evaluated. The time-weighted average levels of dust and noise exposure were taken from Workplace Exposure Assessment data. Apart occupational injuries, sports events, traffic accidents, and other accidents occurring outside workplaces were excluded. The incidences of occupational injury in each factory were calculated by data from the Korea Workers′ Compensation and Welfare Services. Workplaces were classified according to the incidence of any occupational injuries (incident or nonincident workplaces, respectively. Workplace dust exposure was classified as 90 dB. Workplaces with high noise exposure were significantly associated with being incident workplaces, whereas workplaces with high dust exposure were not. The odds ratios (95% confidence intervals derived from a logistic regression model were 1.68 (1.27-2.24 and 3.42 (2.26-5.17 at 80-89 dB and ≥90 dB versus <80 dB. These associations remained significant when in a separate analysis according to high or low dust exposure level. Noise exposure increases the risk of occupational injury in the workplace. Furthermore, the risk of occupational injury increases with noise exposure level in a dose-response relationship. Therefore, strategies for reducing noise exposure level are required to decrease the risk of occupational injury.

  20. Distribution of exposure concentrations and doses for constituents of environmental tobacco smoke

    Energy Technology Data Exchange (ETDEWEB)

    LaKind, J.S. [LaKind Associates (United States); Ginevan, M.E. [M.E. Ginevan and Associates (United States); Naiman, D.Q. [Johns Hopkins Univ., Baltimore, MD (United States). Dept. of Mathematical Sciences; James, A.C. [A.C. James and Associates (United States); Jenkins, R.A. [Oak Ridge National Lab., TN (United States); Dourson, M.L.; Felter, S.P. [TERA (United States); Graves, C.G.; Tardiff, R.G. [Sapphire Group, Inc., Bethesda, MD (United States)

    1999-06-01

    The ultimate goal of the research reported in this series of three articles is to derive distributions of doses of selected environmental tobacco smoke (ETS)-related chemicals for nonsmoking workers. This analysis uses data from the 16-City Study collected with personal monitors over the course of one workday in workplaces where smoking occurred. In this article, the authors describe distributions of ETS chemical concentrations and the characteristics of those distributions for the workplace exposure. Next, they present population parameters relevant for estimating dose distributions and the methods used for estimating those dose distributions. Finally, they derive distributions of doses of selected ETS-related constituents obtained in the workplace for people in smoking work environments. Estimating dose distributions provided information beyond the usual point estimate of dose and showed that the preponderance of individuals exposed to ETS in the workplace were exposed at the low end of the dose distribution curve. The results of this analysis include estimations of hourly maxima and time-weighted average (TWA) doses of nicotine from workplace exposures to ETS and doses derived from modeled lung burdens of ultraviolet-absorbing particulate matter (UVPM) and solanesol resulting from workplace exposures to ETS (extrapolated from 1 day to 1 year).

  1. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  2. Real-time assessment of exposure dose to workers in radiological environments during decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    Jeong, KwanSeong; Choi, ByungSeon; Moon, JeiKwon; Hyun, Dongjun; Lee, Jonghwan; Kim, IkJune; Kim, GeunHo; Seo, JaeSeok; Jeong, SeongYoung; Lee, JungJun; Song, HaeSang; Lee, SangWha; Son, BongKi

    2014-01-01

    Highlights: • The method of exposure dose assessment to workers during decommissioning of nuclear facilities. • The environments of simulation were designed under a virtual reality. • To assess exposure dose to workers, human model was developed within a virtual reality. - Abstract: This objective of this paper is to develop a method to simulate and assess the exposure dose to workers during decommissioning of nuclear facilities. To simulate several scenarios, decommissioning environments were designed using virtual reality. To assess exposure dose to workers, a human model was also developed using virtual reality. The exposure dose was measured and assessed under the principle of ALARA in accordance with radiological environmental change. This method will make it possible to plan for the exposure dose to workers during decommissioning of nuclear facilities

  3. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation.

    Science.gov (United States)

    Bogh, Morten K B; Schmedes, Anne V; Philipsen, Peter A; Thieden, Elisabeth; Wulf, Hans C

    2010-02-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol was measured at baseline. The increase in 25(OH)D level after UVB exposure was negatively correlated with baseline 25(OH)D level (Ppigmentation. In addition, we paired a dark-skinned group with a fair-skinned group according to baseline 25(OH)D levels and found no differences in 25(OH)D increase after identical UVB exposure.

  4. Dose — response relationship between noise exposure and the risk of occupational injury

    Science.gov (United States)

    Yoon, Jin-Ha; Hong, Jeong-Suk; Roh, Jaehoon; Kim, Chi-Nyon; Won, Jong-Uk

    2015-01-01

    Many workers worldwide experience fatality and disability caused by occupational injuries. This study examined the relationship between noise exposure and occupational injuries at factories in Korea. A total of 1790 factories located in northern Gyeonggi Province, Korea was evaluated. The time-weighted average levels of dust and noise exposure were taken from Workplace Exposure Assessment data. Apart occupational injuries, sports events, traffic accidents, and other accidents occurring outside workplaces were excluded. The incidences of occupational injury in each factory were calculated by data from the Korea Workers’ Compensation and Welfare Services. Workplaces were classified according to the incidence of any occupational injuries (incident or nonincident workplaces, respectively). Workplace dust exposure was classified as 90 dB. Workplaces with high noise exposure were significantly associated with being incident workplaces, whereas workplaces with high dust exposure were not. The odds ratios (95% confidence intervals) derived from a logistic regression model were 1.68 (1.27-2.24) and 3.42 (2.26-5.17) at 80-89 dB and ≥90 dB versus occupational injury in the workplace. Furthermore, the risk of occupational injury increases with noise exposure level in a dose-response relationship. Therefore, strategies for reducing noise exposure level are required to decrease the risk of occupational injury. PMID:25599757

  5. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  6. The Potential Neurotoxic Effects of Low-Dose Sarin Exposure in a Guinea Pig Model

    Science.gov (United States)

    2002-01-01

    1 THE POTENTIAL NEUROTOXIC EFFECTS OF LOW-DOSE SARIN EXPOSURE IN A GUINEA PIG MODEL Melinda R. Roberson, PhD, Michelle B. Schmidt...Proving Ground, MD 21010 USA ABSTRACT This study is assessing the effects in guinea pigs of repeated low-dose exposure to the nerve...COVERED - 4. TITLE AND SUBTITLE The Potential Neurotoxic Effects Of Low-Dose Sarin Exposure In A Guinea Pig Model 5a. CONTRACT NUMBER 5b

  7. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  8. Design of spray dried insulin microparticles to bypass deposition in the extrathoracic region and maximize total lung dose.

    Science.gov (United States)

    Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim

    2016-09-25

    Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Chromosomal aberrations and exposure doses during extracorporeal shock wave lithotripsy for renal ureteral stones

    International Nuclear Information System (INIS)

    Shao Songsheng; Feng Jialin; Weng Zhigen; Jiang Qingqi; Wang Guomin; Zhang Yuanfang; Zhang Renan

    1991-01-01

    The radiation dose and the chromosomal aberrations of peripheral lymphocytes were studied in 20 patients during ESWL. The dose was measured with calibrated thermoluminescent dosimeters. Primary results showed an average skin exposure 4.50 x 10 -3 C/kg per case. The dose level is smilar to that of the patients under-going routine fluoroscopic examination. Therefore, the radiation exposure with patients from the ESWL procedure should be considered acceptable. As chromosome changes, to reduce the radiation dose is important for the radiation cytogentics. The factors influencing exposure levels include stone characteristics and physician experience

  10. Health effects and radiation dose from exposure to radon indoors

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1998-01-01

    Radon exposure has been declared a health hazard by several organisations, for example the International Commission on Radiological Protection (ICRP) and the World Health Organisation (WHO). The basis for the risk estimate has been the results from epidemiological studies on miners exposed to radon, supported by the results of residential epidemiology. Only few of the many residential epidemiological studies carried out hitherto have a design applicable for a risk estimate. The largest is the Swedish national study but several large well designed studies are ongoing. An excess risk has also been found in animal research. The model describes smoking and radon exposure as between additive and multiplicative, found in both miners and residential studies. The relatively few non-smokers among the miners and also among the residents give a problem at estimating the radon risk for these groups. It would also be desirable to know more about the importance of the age and the time period at exposure. Lung dose calculations from radon exposure are not recommended by ICRP in their publication 66. For comparison with other radiation sources the ICRP recommends the concept 'dose conversion convention' obtained as the risk estimate divided by the detriment. Other effects of radon exposure than lung cancer have not been shown epidemiologically, but dose calculations indicate an excess risk of about 5% of the excess lung cancer risk. (author)

  11. Measurement of exposure dose rate by TLD in 60Co garden

    International Nuclear Information System (INIS)

    Fan Chengfang; Li Pinfang; Wu Maoliang; Zhao Quan

    1987-01-01

    The use of TLD method to measure exposure dose rate in 60 Co garden is described. As compared with chemical dosimetry, the relative deviation of measurement would not exceed 10%. The good repeatability has been proved by comparing the measurements of different times and distances with correction of decay law and 1/1 2 law. Besides, the distribution of exposure dose rate was influenced by scattering of the living plants

  12. Cytogenetic biological dosimetry. Dose estimative in accidental exposure

    International Nuclear Information System (INIS)

    Santos, O.R. dos; Campos, I.M.A. de.

    1988-01-01

    The methodology of cytogenetic biological dosimetry is studied. The application in estimation of dose in five cases of accidental exposure is reported. An hematological study and culture of lymphocytes is presented. (M.A.C.) [pt

  13. Biomarkers of exposure and dose: State of the art

    International Nuclear Information System (INIS)

    Brooks, A.L.

    2001-01-01

    Biomarkers provide methods to measure changes in biological systems and to relate them to environmental insults and disease processes. Biomarkers can be classified as markers of exposure and dose, markers of sensitivity, and markers of disease. It is important that the differences and applications of the various types of biomarkers be clearly understood. The military is primarily interested in early biomarkers of exposure and dose that do not require high levels of sensitivity but can be used to rapidly triage war fighters under combat or terrorist conditions and determine which, if any, require medical attention. Biomarkers of long-term radiation risk represent the second area of interest for the military. Biomarkers of risk require high sensitivity and specificity for the disease and insult but do not require rapid data turn around. Biomarkers will help provide information for quick command decisions in the field, characterise long-term troop risks and identify early stages of radiation-induced diseases. This information provides major positive reassurances about individual exposures and risk that will minimise the physical and psychological impact of wartime radiation exposures. (author)

  14. Assessment of medical radiation exposure to patients and ambient doses in several diagnostic radiology departments

    Science.gov (United States)

    Sulieman, A.; Elhadi, T.; Babikir, E.; Alkhorayef, M.; Alnaaimi, M.; Alduaij, M.; Bradley, D. A.

    2017-11-01

    In many countries diagnostic medical exposures typically account for a very large fraction of the collective effective dose that can be assigned to anthropological sources and activities. This in part flags up the question of whether sufficient steps are being taken in regard to potential dose saving from such medical services. As a first step, one needs to survey doses to compare against those of best practice. The present study has sought evaluation of the radiation protection status and patient doses for certain key radiological procedures in four film-based radiology departments within Sudan. The radiation exposure survey, carried out using a survey meter and quality control test tools, involved a total of 299 patients their examinations being carried out at one or other of these four departments. The entrance surface air kerma (ESAK) was determined from exposure settings using DosCal software and an Unfors -Xi-meter. The mean ESAK for x-ray examination of the chest was 0.30±0.1 mGy, for the skull it was 0.96±0.7 mGy, for the abdomen 0.85±0.01 mGy, for spinal procedures 1.30±0.6 mGy and for procedures involving the limbs it was 0.43±0.3 mGy. Ambient dose-rates in the reception area, at the closed door of the x-ray room, recorded instantaneous values of up to 100 μSv/h. In regard to protection, the associated levels were found to be acceptable in three of the four departments, corrective action being required for one department, regular quality control also being recommended.

  15. Pulsed total dose damage effect experimental study on EPROM

    International Nuclear Information System (INIS)

    Luo Yinhong; Yao Zhibin; Zhang Fengqi; Guo Hongxia; Zhang Keying; Wang Yuanming; He Baoping

    2011-01-01

    Nowadays, memory radiation effect study mainly focus on functionality measurement. Measurable parameters is few in china. According to the present situation, threshold voltage testing method was presented on floating gate EPROM memory. Experimental study of pulsed total dose effect on EPROM threshold voltage was carried out. Damage mechanism was analysed The experiment results showed that memory cell threshold voltage negative shift was caused by pulsed total dose, memory cell threshold voltage shift is basically coincident under steady bias supply and no bias supply. (authors)

  16. Planning of optimal work path for minimizing exposure dose during radiation work in radwaste storage

    International Nuclear Information System (INIS)

    Kim, Yoon Hyuk; Park, Won Man; Kim, Kyung Soo; Whang, Joo Ho

    2005-01-01

    Since the safety of nuclear power plant has been becoming a big social issue, the exposure dose of radiation for workers has been one of the important factors concerning the safety problem. The existing calculation methods of radiation dose used in the planning of radiation work assume that dose rate dose not depend on the location within a work space, thus the variation of exposure dose by different work path is not considered. In this study, a modified numerical method was presented to estimate the exposure dose during radiation work in radwaste storage considering the effects of the distance between a worker and sources. And a new numerical algorithm was suggested to search the optimal work path minimizing the exposure dose in pre-defined work space with given radiation sources. Finally, a virtual work simulation program was developed to visualize the exposure dose of radiation during radiation works in radwaste storage and provide the capability of simulation for work planning. As a numerical example, a test radiation work was simulated under given space and two radiation sources, and the suggested optimal work path was compared with three predefined work paths. The optimal work path obtained in the study could reduce the exposure dose for the given test work. Based on the results, the developed numerical method and simulation program could be useful tools in the planning of radiation work

  17. Assessment of dose due to exposure to indoor radon and thoron progeny

    Directory of Open Access Journals (Sweden)

    Prasad Ganesh

    2010-01-01

    Full Text Available The components of the effective dose through inhalation from radon and its progeny are important for human health since they contribute to more than 50% of the total radiation dose from natural sources. As a consequence, radon has been identified as the second leading cause of lung cancer after smoking. Radon and its short lived decay products (218Po, 214Pb, 214Bi, 214Po present in dwellings are a radiation hazard, particularly if such sources are concentrated in the enclosed areas like poorly ventilated houses and underground mines. The indoor radon, thoron, and progeny concentrations were measured in a small hilly town of Budhakedar and the surrounding area of Tehri Garhwal, India, by using LR-115 Type II plastic track detector in a twin cup radon dosimeter. The concentrations of radon progeny were measured as the highest in winter and the lowest in summer while the thoron progeny concentration was found maximum in rainy season and minimum in autumn. The annual exposure to the potential alpha energy of radon and thoron were found to vary from 0.04 WLM to 0.69 WLM with an average value of 0.29 WLM, and 0.03 WLM to 0.37 WLM with an aver- age value of 0.16 WLM, respectively. The annual effective dose due to the exposure to indoor radon and progeny in Budhakedar homes was found to vary from 0.16 mSv to 2.72 mSv with an average value of 1.14 mSv and the effective dose due to the exposure to thoron and progeny was found to vary from 0.18 mSv to 2.49 mSv with an average value of 1.05 mSv. The results of systematic study have been obtained by considering the room as a space in which the radon and thoron levels are directly related to the dynamic and static parameters.

  18. Significance of lenticular opacity from the view point of the exposure dose of A-bomb radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, S [Sugimoto Hospital, Hiroshima (Japan)

    1975-04-01

    Two cases of lenticular opacity were discussed from the view point of exposure dose of A-bomb radiation. Case 1: female, 22 year and 5 months old when she was exposured to A-bomb radiation. The presumed exposure dose was 482.0 rad. Cataract due to A-bomb radiation. Case 2: female, 21 years and 6 months old when she was exposured to A-bomb radiation. The presumed exposure dose was more than 1,000 rad. Cataract due to A-bomb radiation and incipient cataract senilis. It was reported here that there was a marked difference in opacity findings of cataract due to A-bomb radiation in accordance with difference in exposure dose of radiation. It was also presumed from the findings of incipient cataract senilis that with increasing exposure dose, the aging phenomenon was promoted.

  19. Radiation dose during mammography using various recording systems

    International Nuclear Information System (INIS)

    Heep, H.; Buelow-Johansen, T.; Klemencic, J.; Wegwitz, J.; Stadtkrankenhaus Offenbach

    1978-01-01

    Patient dose during mammography for various recording systems, such as film, film-screen combination and xeromammography was measured by thermoluminescent densitometers. In the first set of experiments we measured dose per exposure, in a second set total surface dose at five points on the breast, using the following combintions: a) Two industrial film exposures and one xeromammographic exposure. b) two film-screen exposures and one xeromammographic exposure. c) One industrial film and two xeromammographic exposures. (orig.) [de

  20. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  1. The use of gamma-H2AX as a biodosimeter for total-body radiation exposure in non-human primates.

    Directory of Open Access Journals (Sweden)

    Christophe E Redon

    2010-11-01

    Full Text Available There is a crucial shortage of methods capable of determining the extent of accidental exposures of human beings to ionizing radiation. However, knowledge of individual exposures is essential for early triage during radiological incidents to provide optimum possible life-sparing medical procedures to each person.We evaluated immunocytofluorescence-based quantitation of γ-H2AX foci as a biodosimeter of total-body radiation exposure ((60Co γ-rays in a rhesus macaque (Macaca mulatta model. Peripheral blood lymphocytes and plucked hairs were collected from 4 cohorts of macaques receiving total body irradiation doses ranging from 1 Gy to 8.5 Gy. Each cohort consisted of 6 experimental and 2 control animals. Numbers of residual γ-H2AX foci were proportional to initial irradiation doses and statistically significant responses were obtained until 1 day after 1 Gy, 4 days after 3.5 and 6.5 Gy, and 14 days after 8.5 Gy in lymphocytes and until 1 day after 1 Gy, at least 2 days after 3.5 and 6.5 Gy, and 9 days after 8.5 Gy in plucked hairs.These findings indicate that quantitation of γ-H2AX foci may make a robust biodosimeter for analyzing total-body exposure to ionizing radiation in humans. This tool would help clinicians prescribe appropriate types of medical intervention for optimal individual outcome. These results also demonstrate that the use of a high throughput γ-H2AX biodosimeter would be useful for days post-exposure in applications like large-scale radiological events or radiation therapy. In addition, this study validates a possibility to use plucked hair in future clinical trials investigating genotoxic effects of drugs and radiation treatments.

  2. The revision of dose limits for exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Hughes, D.

    1990-01-01

    The paper reviews the current dose limits for exposure to ionizing radiations and the risk factors on which they are based, and summarizes the revised risk factors and the draft proposals for new dose limits published by the International Commission on Radiological Protection. (author)

  3. Comparison of occupational radiation dose exposures in nuclear medicine and PET

    International Nuclear Information System (INIS)

    White, S.A.; Binns, D.S.; Johnston, V.K.; Fawcett, M.F.; Greer, B.; Hicks, R.J.

    1999-01-01

    Full text: With the increasing use of high-dose 64 Ga, 201 TI and 18 F-fluorodeoxyglucose (FDG) PET for scanning in oncology in our centre, a radiation dose survey was performed to determine the impact on staff exposure in a multi-modality department. This study was set up in part to counter 'radio-phobia' (the fear of working with radioactive patients) in allied health professionals. The patients were measured using a hand-held radiation monitor at various distances and times which replicate typical patient contact scenarios in the Diagnostic Imaging Department. An average exposure rate per hour was calculated and thus the relative radiation hazard was determined for staff who will interact with the patient outside of the hot laboratory. We present our findings from the survey and the implications these have on staff radiation exposure. In conclusion, these data suggest that emerging oncologic techniques such as PET, high-dose 67 Ga and high-dose 201 Tl do not represent a significantly greater occupational radiation hazard than conventional nuclear medicine procedures

  4. Use of BEIR V and UNSCEAR 1988 in radiation risk assessment: Lifetime total cancer mortality risk estimates at low doses and low dose rates for low-LET radiation

    International Nuclear Information System (INIS)

    1992-12-01

    In November 1986, the Department of Defense (DoD) asked the Committee on Interagency Radiation Research and Policy Coordination (CIRRPC) to develop a coordinated Federal position on risk assessment for low levels of ionizing radiation. Since Federal risk assessment activities are based primarily on the scientific data and analyses in authoritative review documents prepared by groups like the National Academy of Sciences' Committee on the Biological Effects of Ionizing Radiation (BEIR), the National Council on Radiation Protection and Measurements (NCRP) and the United Nations' Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), DoD proposed that the CIRRPC Science Panel undertake the task of providing coordinated interagency positions on the use of information in the reports of such groups. The practice has been for individual Federal agencies to interpret and decide independently how to use the information provided in such reports. As a result of its deliberations, the Subpanel recommends two nominal risk estimates for lifetime total cancer mortality following whole-body exposure to low levels of low-LET ionizing radiation, one for the general population and one for the working-age population (see Section II). The recommended risk estimates reflect the general agreement of information in BEIR V and UNSCEAR 1988 for total cancer mortality. The Subpanel's risk estimates and associated statements are intended to meet the needs of the Federal agencies for: (a) values that are current; (b) values that are relevant to the low-dose and low dose-rate ionizing radiation exposures principally encountered in carrying out Federal responsibilities; (c) a statement of the change in the estimates of lifetime total cancer mortality relative to estimates in previous authoritative review documents; and (d) a practical statement on the scientific uncertainty associated with applying the lifetime total cancer mortality values at very low doses

  5. Critical Dose of Internal Organs Internal Exposure - 13471

    Energy Technology Data Exchange (ETDEWEB)

    Grigoryan, G.; Amirjanyan, A. [Nuclear and Radiation Safety Centre (Armenia); Grigoryan, N. [Yerevan State Medical University 4Tigran Mets,375010 Yerevan (Armenia)

    2013-07-01

    The health threat posed by radionuclides has stimulated increased efforts to developed characterization on the biological behavior of radionuclides in humans in all ages. In an effort motivated largely by the Chernobyl nuclear accident, the International Commission on Radiological Protection (ICRP) is assembling a set of age specific biokinetic models for environmentally important radioelements. Radioactive substances in the air, mainly through the respiratory system and digestive tract, is inside the body. Radioactive substances are unevenly distributed in various organs and tissues. Therefore, the degree of damage will depend not only on the dose of radiation have but also on the critical organ, which is the most accumulation of radioactive substances, which leads to the defeat of the entire human body. The main objective of radiation protection, to avoid exceeding the maximum permissible doses of external and internal exposure of a person to prevent the physical and genetic damage people. The maximum tolerated dose (MTD) of radiation is called a dose of radiation a person in uniform getting her for 50 years does not cause changes in the health of the exposed individual and his progeny. The following classification of critical organs, depending on the category of exposure on their degree of sensitivity to radiation: First group: the whole body, gonads and red bone marrow; Second group: muscle, fat, liver, kidney, spleen, gastrointestinal tract, lungs and lens of the eye; The third group: bone, thyroid and skin; Fourth group: the hands, forearms, feet. MTD exposure whole body, gonads and bone marrow represent the maximum exposures (5 rem per year) experienced by people in their normal activities. The purpose of this article is intended dose received from various internal organs of the radionuclides that may enter the body by inhalation, and gastrointestinal tract. The biokinetic model describes the time dependent distribution and excretion of different

  6. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Van; Little, Mark P. [National Cancer Institute, Radiation Epidemiology Branch, Rockville, MD (United States)

    2017-11-15

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and

  7. Estimation of lung tissue doses following exposure to low-LET radiation in the Canadian study of cancer following multiple fluoroscopies

    International Nuclear Information System (INIS)

    Howe, G.R.; Yaffe, M.

    1992-02-01

    Lung tissue doses from exposure to external low-LET radiation have been estimated for each year between 1930 and 1960 for 92,707 tuberculosis patients first treated in Canadian institutions between 1930 and 1952. Many of these patients received multiple chest fluoroscopies together with treatment by artificial pneumothorax, and thus accumulated doses up to 15.7 grays. The estimated doses have been used in a statistical analysis of lung cancer mortality between 1950 and 1987 occurring among 64,698 patients known to be alive at the start of 1950, and followed by linkage to the Canadian national mortality data base. There were substantial variations in the total cumulative lung tissue dose received by the cohort, with 2,490 individuals having doses in excess of 1.7 grays. A total of 1,156 lung cancer deaths was observed in the cohort, and these have been used to estimate relative risks. The most appropriate risk model appears to be a simple linear relative risk function, with an excess relative risk coefficient of 0.089 for an absorbed dose of 1 gray. This contrasts with estimates of relative risk based on the atomic bomb survivors study, for which the excess relative risk coefficient for males 20 years after the first exposure is estimated to be 0.64. The difference is statistically significant. It is postulated that fractionation and dose rate effectiveness factors may account for some of the discrepancy. (Modified author abstract) (14 refs., 20 tabs.)

  8. A comparative analysis of exposure doses between the radiation workers in dental and general hospital

    International Nuclear Information System (INIS)

    Yang, Nam Hee; Chung, Woon Kwan; Dong, Kyung Rae; Ju, Yong Jin; Song, Ha Jin; Choi, Eun Jin

    2015-01-01

    Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higher in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workers. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum 50 mSv y -1 ). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the future. Should try to minimize the radiation individual dose of

  9. A comparative analysis of exposure doses between the radiation workers in dental and general hospital

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Nam Hee; Chung, Woon Kwan; Dong, Kyung Rae; Ju, Yong Jin; Song, Ha Jin [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Choi, Eun Jin [Dept. of Public Health and Medicine, Dongshin University, Naju (Korea, Republic of)

    2015-02-15

    Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higher in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workers. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum 50 mSv y{sup -1}). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the future. Should try to minimize the radiation individual dose of

  10. Total dose effects on the matching properties of deep submicron MOS transistors

    International Nuclear Information System (INIS)

    Wang Yuxin; Hu Rongbin; Li Ruzhang; Chen Guangbing; Fu Dongbing; Lu Wu

    2014-01-01

    Based on 0.18 μm MOS transistors, for the first time, the total dose effects on the matching properties of deep submicron MOS transistors are studied. The experimental results show that the total dose radiation magnifies the mismatch among identically designed MOS transistors. In our experiments, as the radiation total dose rises to 200 krad, the threshold voltage and drain current mismatch percentages of NMOS transistors increase from 0.55% and 1.4% before radiation to 17.4% and 13.5% after radiation, respectively. PMOS transistors seem to be resistant to radiation damage. For all the range of radiation total dose, the threshold voltage and drain current mismatch percentages of PMOS transistors keep under 0.5% and 2.72%, respectively. (semiconductor devices)

  11. Vitamin D production after UVB exposure depends on baseline vitamin D and total cholesterol but not on skin pigmentation

    DEFF Research Database (Denmark)

    Bogh, Morten K B; Schmedes, Anne; Philipsen, Peter A

    2010-01-01

    UVB radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) (25(OH)D), but the influence of skin pigmentation, baseline 25(OH)D level, and total cholesterol has not been well characterized. To determine the importance of skin pigmentation, baseline 25(OH)D level, and total...... cholesterol on 25(OH)D production after UVB exposure, 182 persons were screened for 25(OH)D level. A total of 50 participants with a wide range in baseline 25(OH)D levels were selected to define the importance of baseline 25(OH)D level. Of these, 28 non-sun worshippers with limited past sun exposure were used...... to investigate the influence of skin pigmentation and baseline total cholesterol. The participants had 24% of their skin exposed to UVB (3 standard erythema doses) four times every second or third day. Skin pigmentation and 25(OH)D levels were measured before and after the irradiations. Total cholesterol...

  12. A study of radiation exposure dose in young dental patients

    International Nuclear Information System (INIS)

    Hatakeyama, Atsushi

    1983-01-01

    In order to clarify the trend in dental radiography for young patients up to 18 years old and the accompanying radiation exposures, surveys were made at Fukuoka Dental College Hospital and thirty-five dental offices in Fukuoka city and Kitakyushu city. Each kind of radiography increased in average number with age and 16-18 group was given 4.60 times of radiography of one kind or another in the clinic of college hospital. In the dental offices, the number of radiography taken was about one-fourth that of the clinic of college hospital. Although exposure dose varies with exposure factors, distance and angle of exposure, in addition to time factor, were found to affect doses subtly. In the clinic of college hospital the average of estimated doses to organs per person per year were 105.4 mrad (25.2 mrad for 5-year-old children) in the salivary gland, 55.9 mrad (18.9 mrad for 5-year-old) in the thyroid gland, 52.1 mrad (15.0 mrad for 5-year-old) in the lens of the eye and 52.2 mrad (8.7 mrad for 5-year-old) in the sella turcica. In the dental offices, the same average of estimated doses to organs were 40.5 mrad (7.4 mrad for 5-year-old) in the salivary gland, 17.4 mrad (8.0 mrad for 5-year-old) in the thyroid gland, 12.2 mrad (6.1 mrad for 5-year-old) in the lens of eye and 13.1 mrad (1.3 mrad for 5-year-old) in the sella turcica. In all kinds of radiograpy, the estimated doses in genital glands were in μrad. In the dental offices, both the percentage of young patients to all patients and the radiographing rate were lower as compared with those in the clinic of college hospital. The estimated doses were also lower at one-half to one-fifth and those by age and by organ were found to be one-tenth or lower. (J.P.N.)

  13. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  14. The monetary value of the averted dose for public exposure

    International Nuclear Information System (INIS)

    Katona, T.; Eged, K.; Kanyar, B.; Kis, Z.; Nenvei, A.

    2002-01-01

    In general, the concept of optimisation in radiation protection and safety appears as cost-minimisation in new procedures, methods in practices, and/or protective actions following unacceptable contamination. In the practical implementation of the concept, the cost of protective actions should be balanced with the benefits of exposure reduction. The monetary value of the averted dose can be assessed by the product of the cost of unit avoided collective dose (alpha-value) and the averted collective dose (ICRP 1991, 1993). According to the ICRP and others, the monetary value of the averted dose - in addition to the avoided health detriment - needs to take into account economical and social circumstances, ethical factors etc. (ICRP 1993, 2000; IBSS 1995; Oughton 2000). Most of the alpha-value assessments have been performed for workers (Hardeman et al. 1998; Lefaure 1998). Due to the different dose limitations and action levels for public exposures the monetary value of the averted dose may vary whether the averted dose refers to workers or to the public. Until now, only a few investigations have been performed to the public exposures. Eeckhoudt et al. (1999) proposed a method based on compensation dependency and on comparisons between the workers and the general public. The present paper includes the results obtained by the WTP method for the public. The questionnaire and analysis were developed by the CEPN (Centre d'Etude sur L'Evaluation de la Protection dans le Domaine Nucleaire, France) for specialists in the nuclear field (Leblanc et al. 1994). In 2000, questionnaire modifications were first introduced to adjust the Hungarian factors (Eged et al. 2001, 2002). The questionnaire was further modified in 2001 to take into account the Hungarian public factors

  15. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  16. Occupational radiation exposure to low doses of ionizing radiation and female breast cancer

    International Nuclear Information System (INIS)

    Adelina, P.; Bliznakov, V.; Bairacova, A.

    2003-01-01

    The aim of this study is to examine the relationship between past occupational radiation exposure to low doses of ionizing radiation and cases of diagnosed and registered breast cancer [probability of causation - PC] among Bulgarian women who have used different ionizing radiation sources during their working experience. The National Institute of Health (NIH) in US has developed a method for estimating the probability of causation (PC) between past occupational radiation exposure to low doses of ionizing radiation and cases of diagnosed cancer. We have used this method. A group of 27 women with diagnosed breast cancer has been studied. 11 of them are former workers in NPP - 'Kozloduy', and 16 are from other sites using different sources of ionizing radiation. Analysis was performed for 14 women, for whom full personal data were available. The individual radiation dose for each of them is below 1/10 of the annual dose limit, and the highest cumulative dose for a period of 14 years of occupational exposure is 50,21 mSv. The probability of causation (PC) values in all analyzed cases are below 1%, which confirms the extremely low probability of causation (PC) between past occupational radiation exposure to low doses of ionizing radiation and occurring cases of breast cancer. (orig.)

  17. Dental roentgenographic exposure in Hiroshima and Nagasaki. Part 4. Critical organ doses

    Energy Technology Data Exchange (ETDEWEB)

    Antoku, S; Kihara, T; Russell, W J

    1972-01-01

    Doses to Adult Health Study subjects from dental x-ray examinations were estimated, based on previous patient and hospital surveys, and by exposing phantom humans containing LiF thermoluminescence dosimeters and ionization chambers. Dose tables were compiled according to representative exposure conditions and average doses were estimated at various body sites during dental roentgenography. Dental roentgenography was found to comprise a relatively small segment of the contaminating sources of ionizing radiation exposure among this population. However, the increasing use of full mouth examinations bides caution in the future (11 tables). (DLC)

  18. Consequences of the exposure at low dose rates-contribution of animal experimentation

    International Nuclear Information System (INIS)

    Masse, R.

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate [fr

  19. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R. [CEA Centre d`Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection Technique; Pineau, J.F. [ALGADE, Bessines (France); Chameaud, J. [Compagnie Generale des Matieres Nucleaires (COGEMA), 87 - Razes (France)

    1994-12-31

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10{sup 6} J.m{sup -3} (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author).

  20. Lung cancer incidence after exposure of rats to low doses of radon: influence of dose rate

    International Nuclear Information System (INIS)

    Morlier, J.P.; Morin, M.; Monchaux, G.; Fritsch, P.; Lafuma, J.; Masse, R.; Chameaud, J.

    1994-01-01

    To study the effect on lung cancer incidence of a long exposure to low levels of radon, 500 male 3-months-old Sprague-Dawley rats, were exposed to a cumulative dose of 25 WLM of radon and its daughters, 6 hours a day, 5 days a week, during 18 months. Exposure conditions were controlled in order to maintain a defined PAEC: 42 x 10 6 J.m -3 (2 WL), in the range of domestic and environmental exposures. Animals were kept until they died or given euthanasia when moribund. Mean survival times were similar in both irradiated and control groups: 828 days (SD = 169) and 830 days (SD = 137), as well as lung cancer incidence, 0.60% at 25 WLM and 0.63% for controls. The incidence of lung lesions was compared statistically with controls and those previously obtained at cumulative exposures of 25 and 50 WLM delivered over a 4-6 month period, inducing a significant increase of lung cancer, 2.2% and 3.8% respectively. Such a comparison showed a decreased lung cancer incidence related to a decrease in the dose rate for low levels of radon exposure. (author)

  1. Low-dose-rate total lymphoid irradiation: a new method of rapid immunosuppression

    International Nuclear Information System (INIS)

    Blum, J.E.; de Silva, S.M.; Rachman, D.B.; Order, S.E.

    1988-01-01

    Total Lymphoid Irradiation (TLI) has been successful in inducing immunosuppression in experimental and clinical applications. However, both the experimental and clinical utility of TLI are hampered by the prolonged treatment courses required (23 days in rats and 30-60 days in humans). Low-dose-rate TLI has the potential of reducing overall treatment time while achieving comparable immunosuppression. This study examines the immunosuppressive activity and treatment toxicity of conventional-dose-rate (23 days) vs low-dose-rate (2-7 days) TLI. Seven groups of Lewis rats were given TLI with 60Co. One group was treated at conventional-dose-rates (80-110 cGy/min) and received 3400 cGy in 17 fractions over 23 days. Six groups were treated at low-dose-rate (7 cGy/min) and received total doses of 800, 1200, 1800, 2400, 3000, and 3400 cGy over 2-7 days. Rats treated at conventional-dose-rates over 23 days and at low-dose-rate over 2-7 days tolerated radiation with minimal toxicity. The level of immunosuppression was tested using allogeneic (Brown-Norway) skin graft survival. Control animals retained allogeneic skin grafts for a mean of 14 days (range 8-21 days). Conventional-dose-rate treated animals (3400 cGy in 23 days) kept their grafts 60 days (range 50-66 days) (p less than .001). Low-dose-rate treated rats (800 to 3400 cGy total dose over 2-7 days) also had prolongation of allogeneic graft survival times following TLI with a dose-response curve established. The graft survival time for the 3400 cGy low-dose-rate group (66 days, range 52-78 days) was not significantly different from the 3400 cGy conventional-dose-rate group (p less than 0.10). When the total dose given was equivalent, low-dose-rate TLI demonstrated an advantage of reduced overall treatment time compared to conventional-dose-rate TLI (7 days vs. 23 days) with no increase in toxicity

  2. Anxiogenic effects of chronic exposure to nandrolone decanoate (ND) at supraphysiological dose in rats: a brief report.

    Science.gov (United States)

    Rosic, Gvozden; Joksimovic, Jovana; Selakovic, Dragica; Milovanovic, Dragan; Jakovljevic, Vladimir

    2014-01-01

    Nandrolone decanoate (ND) is frequently used anabolic androgenic steroid (AAS) among the athletes. Despite the health risks, there is significant increase in prevalence of AAS abuse. The aim of this study was to investigate the effects of chronic exposure to ND at supraphysiological dose (to mimic the doses for human AAS abusers) on anxiety levels in adult rats. We performed several behavioral tests (open field test, elevated plus maze test, beam-walking test, evoked beam-walking test and tail suspension test) for estimation of anxiety in rats. Adult rats received 20 mg/kg intraperitoneal injection of ND weekly for four weeks. Behavioral test were performed on the seventh day after the last dose of ND. Anxiogenic-like pattern of behavior was clearly observed in several behavioral tests, such as open field test (decrease of total distance moved and cumulative duration of moving, decrease of an average velocity of the animals, decrease of frequency and total time in centre zone); elevated plus maze (decreased total time spent in open arms and the number of entries in open arms of the elevated plus maze); evoked beam-walking test (decreased time to cross the beam) and tail suspension test (increased latency to first immobility and decreased total duration of immobility). Results of this study show that four-week treatment with the supraphysiological dose of ND produced anxiogenic effects in sedentary male rats. Our results show that rats after chronic treatment with a supraphysiological dose of ND exhibited anxiety-like behavior.

  3. Study on the method or reducing the operator's exposure dose from a C-Arm system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Sik; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of); Kim, Seung Ok [Dept. of Radiology, Catholic Kwangdong Universty International ST.Mary' s Hospital, Incheon (Korea, Republic of)

    2016-12-15

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment.

  4. New Insights into Fully-Depleted SOI Transistor Response During Total Dose Irradiation

    International Nuclear Information System (INIS)

    Burns, J.A.; Dodd, P.E.; Keast, C.L.; Schwank, J.R.; Shaneyfelt, M.R.; Wyatt, P.W.

    1999-01-01

    Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. No evidence was found for total-dose induced snap back. These results have implications for hardness assurance testing

  5. Exposure dose in recent treatment of nuclear medicine and countermeasures

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1974-01-01

    Radioactive pharmaceuticals widely used for the diagnosis in nuclear medicine utilize radiation as tracer for dynamic behavior measurement and locality diagnosis, and the exposure due to their use has very little chance to attain the maximum permissible dose of ICRP. The MIRD (Medical Internal Radiation Dose) method tends to be adopted for the measurement of internally absorbed dose due to radio-pharmaceuticals in future. The feature of the MIRD method is that the targeted object is not a critical organ but the region of interest, and the source organ and target organ are fully taken into consideration. Recently, the exposure of patients has been significantly lowered by applying sup(99m)Tc and the like. Though the contribution to national dose is small, it is required to perform immediate conversion from the older nuclear medicine typified with conventional 131 I, 198 Au and 203 Hg to modern one centering around sup(99m)Tc. The problems in calculating the absorbed dose due to nuclear medicine diagnosis are very low accuracy of biological data though the high accuracy of data in physics has been achieved, and the difficulty to obtain data for calculating patients' absorbed dose in routine inspection. (Wakatsuki, Y.)

  6. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  7. Simulation experiment on total ionization dose effects of linear CCD

    International Nuclear Information System (INIS)

    Tang Benqi; Zhang Yong; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2004-01-01

    We carry out the ionization radiation experiment of linear CCDs operated in unbiased, biased, biased and driven mode respectively by Co-60 γ source with our self-designed test system, and offline test the Dark signal and Saturation voltage and SNR varied with total dose for TCD132D, and get some valuable results. On the basis of above work, we set forth a primary experiment approaches to simulate the total dose radiation effects of charge coupled devices. (authors)

  8. Doses of external exposure in Jordan house due to gamma-emitting natural radionuclides in building materials.

    Science.gov (United States)

    Al-Jundi, J; Ulanovsky, A; Pröhl, G

    2009-10-01

    The use of building materials containing naturally occurring radionuclides as (40)K, (232)Th, and (238)U and their progeny results in external exposures of the residents of such buildings. In the present study, indoor dose rates for a typical Jordan concrete room are calculated using Monte Carlo method. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling are assumed. Using activity concentrations of natural radionuclides typical for the Jordan houses and assuming them to be in secular equilibrium with their progeny, the maximum annual effective doses are estimated to be 0.16, 0.12 and 0.22 mSv a(-1) for (40)K, (232)Th- and (238)U-series, respectively. In a total, the maximum annual effective indoor dose due to external gamma-radiation is 0.50 mSv a(-1). Additionally, organ dose coefficients are calculated for all organs considered in ICRP Publication 74. Breast, skin and eye lenses have the maximum equivalent dose rate values due to indoor exposures caused by the natural radionuclides, while equivalent dose rates for uterus, colon (LLI) and small intestine are found to be the smallest. More specifically, organ dose rates (nSv a(-1)per Bq kg(-1)) vary from 0.044 to 0.060 for (40)K, from 0.44 to 0.60 for radionuclides from (238)U-series and from 0.60 to 0.81 for radionuclides from (232)Th-series. The obtained organ and effective dose conversion coefficients can be conveniently used in practical dose assessment tasks for the rooms of similar geometry and varying activity concentrations and local-specific occupancy factors.

  9. Dose-rate effects of ethylene oxide exposure on developmental toxicity.

    Science.gov (United States)

    Weller, E; Long, N; Smith, A; Williams, P; Ravi, S; Gill, J; Henessey, R; Skornik, W; Brain, J; Kimmel, C; Kimmel, G; Holmes, L; Ryan, L

    1999-08-01

    In risk assessment, evaluating a health effect at a duration of exposure that is untested involves assuming that equivalent multiples of concentration (C) and duration (T) of exposure have the same effect. The limitations of this approach (attributed to F. Haber, Zur Geschichte des Gaskrieges [On the history of gas warfare], in Funf Vortrage aus den Jahren 1920-1923 [Five lectures from the years 1920-1923], 1924, Springer, Berlin, pp. 76-92), have been noted in several studies. The study presented in this paper was designed to specifically look at dose-rate (C x T) effects, and it forms an ideal case study to implement statistical models and to examine the statistical issues in risk assessment. Pregnant female C57BL/6J mice were exposed, on gestational day 7, to ethylene oxide (EtO) via inhalation for 1.5, 3, or 6 h at exposures that result in C x T multiples of 2100 or 2700 ppm-h. EtO was selected because of its short half-life, documented developmental toxicity, and relevance to exposures that occur in occupational settings. Concurrent experiments were run with animals exposed to air for similar periods. Statistical analysis using models developed to assess dose-rate effects revealed significant effects with respect to fetal death and resorptions, malformations, crown-to-rump length, and fetal weight. Animals exposed to short, high exposures of EtO on day 7 of gestation were found to have more adverse effects than animals exposed to the same C x T multiple but at longer, lower exposures. The implication for risk assessment is that applying Haber's Law could potentially lead to an underestimation of risk at a shorter duration of exposure and an overestimation of risk at a longer duration of exposure. Further research, toxicological and statistical, are required to understand the mechanism of the dose-rate effects, and how to incorporate the mechanistic information into the risk assessment decision process.

  10. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  11. An overview of measuring and modelling dose and risk from ionising radiation for medical exposures

    International Nuclear Information System (INIS)

    Tootell, Andrew; Szczepura, Katy; Hogg, Peter

    2014-01-01

    Purpose: This paper gives an overview of the methods that are used to calculate dose and risk from exposure to ionizing radiation as a support to other papers in this special issue. Background: The optimization of radiation dose is a legal requirement in medical exposures. This review paper aims to provide the reader with knowledge of dose by providing definitions and concepts of absorbed, effective and equivalent dose. Criticisms of the use of effective dose to infer the risk of an exposure to an individual will be discussed and an alternative approach considering the lifetime risks of cancer incidence will be considered. Prior to any dose or risk calculation, data concerning the dose absorbed by the patient needs to be collected. This paper will describe and discuss the main concepts and methods that can be utilised by a researcher in dose assessments. Concepts behind figures generated by imaging equipment such as dose-area-product, computed tomography dose index, dose length product and their use in effective dose calculations will be discussed. Processes, advantages and disadvantages in the simulation of exposures using the Monte Carlo method and direct measurement using digital dosimeters or thermoluminescent dosimeters will be considered. Beyond this special issue, it is proposed that this paper could serve as a teaching or CPD tool for personnel working or studying medical imaging

  12. Subacute Low Dose Nerve Agent Exposure Causes DNA Fragmentation in Guinea Pig Leukocytes

    Science.gov (United States)

    2005-10-01

    1 SUBACUTE LOW DOSE NERVE AGENT EXPOSURE CAUSES DNA FRAGMENTATION IN GUINEA PIG LEUKOCYTES. Jitendra R. Dave1, John R. Moffett1, Sally M...DNA fragmentation in blood leukocytes from guinea pigs by ‘Comet’ assay after exposure to soman at doses ranging from 0.1LD50 to 0.4 LD50, once per...computer. Data obtained for exposure to soman demonstrated significant increases in DNA fragmentation in circulating leukocytes in CWNA treated guinea pigs as

  13. Radiation Exposure During Uterine Artery Embolization: Effective Measures to Minimize Dose to the Patient

    Energy Technology Data Exchange (ETDEWEB)

    Scheurig-Muenkler, Christian, E-mail: christian.scheurig@charite.de [Charité Universitaetsmedizin Berlin, Department of Diagnostic and Interventional Radiology (Germany); Powerski, Maciej J., E-mail: maciej.powerski@med.ovgu.de [University of Magdeburg, Department of Radiology and Nuclear Medicine (Germany); Mueller, Johann-Christoph, E-mail: johann-christoph.mueller@charite.de [Charité Universitaetsmedizin Berlin, Department of Diagnostic and Interventional Radiology (Germany); Kroencke, Thomas J., E-mail: Thomas.Kroencke@klinikum-augsburg.de [Klinikum Augsburg, Department of Radiology (Germany)

    2015-06-15

    PurposeEvaluation of patient radiation exposure during uterine artery embolization (UAE) and literature review to identify techniques minimizing required dose.MethodsA total of 224 of all included 286 (78 %) women underwent UAE according to a standard UAE-protocol (bilateral UAE from unilateral approach using a Rösch inferior mesenteric and a microcatheter, no aortography, no ovarian artery catheterization or embolization) and were analyzed for radiation exposure. Treatment was performed on three different generations of angiography systems: (I) new generation flat-panel detector (N = 108/151); (II) classical image amplifier and pulsed fluoroscopy (N = 79/98); (III) classical image amplifier and continuous fluoroscopy (N = 37/37). Fluoroscopy time (FT) and dose-area product (DAP) were documented. Whenever possible, the following dose-saving measures were applied: optimized source-object, source-image, and object-image distances, pulsed fluoroscopy, angiographic runs in posterior-anterior direction with 0.5 frames per second, no magnification, tight collimation, no additional aortography.ResultsIn a standard bilateral UAE, the use of the new generation flat-panel detector in group I led to a significantly lower DAP of 3,156 cGy × cm{sup 2} (544–45,980) compared with 4,000 cGy × cm{sup 2} (1,400–13,000) in group II (P = 0.033). Both doses were significantly lower than those of group III with 8,547 cGy × cm{sup 2} (3,324–35,729; P < 0.001). Other reasons for dose escalation were longer FT due to difficult anatomy or a large leiomyoma load, additional angiographic runs, supplementary ovarian artery embolization, and obesity.ConclusionsThe use of modern angiographic units with flat panel detectors and strict application of methods of radiation reduction lead to a significantly lower radiation exposure. Target DAP for UAE should be kept below 5,000 cGy × cm{sup 2}.

  14. Total dose effects on ATLAS-SCT front-end electronics

    CERN Document Server

    Ullán, M; Dubbs, T; Grillo, A A; Spencer, E; Seiden, A; Spieler, H; Gilchriese, M G D; Lozano, M

    2002-01-01

    Low dose rate effects (LDRE) in bipolar technologies complicate the hardness assurance testing for high energy physics applications. The damage produced in the ICs in the real experiment can be underestimated if fast irradiations are carried out, while experiments done at the real dose rate are usually unpractical due to the still high total doses involved. In this work the sensitivity to LDRE of two bipolar technologies proposed for the ATLAS-SCT experiment at CERN is evaluated, finding one of them free of those effects. (12 refs).

  15. Radiation effects after low dose chronic long-term exposure

    International Nuclear Information System (INIS)

    Fliedner, T.M.; Friesecke, I.

    1997-01-01

    This document approaches the radiation effects after low dose chronic long-term exposure, presenting examples occurred, the pathophysiologic mechanisms for cell system tolerance in elevated radiation fields, and the diagnostic and therapeutic possibilities

  16. Dose estimate of exposure to radioisotopes in molecular and cellular biology

    International Nuclear Information System (INIS)

    Onado, C.; Faretta, M.; Ubezio, P.

    1999-01-01

    A method for prospectively evaluating the annual equivalent doses and effective dose to biomedical researchers working with unsealed radioisotopes, and their classification, is presented here. Simplified formulae relate occupational data to a reasonable overestimate of the annual effective dose, and the equivalent doses to the hands and to the skin. The procedure, up to the classification of personnel and laboratories, can be made fully automatic, using a common spreadsheet on a personal computer. The method is based on occupational data, accounting for the amounts of each radioisotope used by a researcher, the time of exposure and the overall amounts employed in the laboratories where experiments are performed. The former data serve to forecast a contribution to the dose arising from a researcher's own work, the latter to a forecast of an 'environmental' contribution deriving simply from the presence in a laboratory where other people are working with radioisotopes. The estimates of the doses due to one's own radioisotope handling and to 'environment' were corrected for accidental exposure, considered as a linear function of the manipulated activity or of the time spent in the laboratories respectively, and summed up to give the effective dose. The effective dose associated with some common experiments in molecular and cellular biology is pre-evaluated by this method. (author)

  17. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  18. Dietary acrylamide exposure of the French population: results of the second French Total Diet Study.

    Science.gov (United States)

    Sirot, Véronique; Hommet, Frédéric; Tard, Alexandra; Leblanc, Jean-Charles

    2012-03-01

    Acrylamide is a heat-induced carcinogen compound that is found in some foods consequently to cooking or other thermal processes. In the second French Total Diet Study (TDS), acrylamide was analysed in 192 food samples collected in mainland France to be representative of the population diet and prepared "as consumed". Highest mean concentrations were found in potato chips/crisps (954 μg/kg), French fries and other fried potatoes (724 μg/kg), and salted biscuits other than potato chips (697 μg/kg). Exposure of general adult and child populations was assessed by combining analytical results with national consumption data. Mean acrylamide exposure was assessed to be 0.43±0.33 μg/kg of body weight (bw) per day for adults and 0.69±0.58 μg/kg bw/day for children. Although the exposure assessed is lower than in previous evaluations, the calculated margins of exposure, based on benchmark dose limits defined for carcinogenic effects, remain very low especially for young children (below 100 at the 95th percentile of exposure), indicating a health concern. It is therefore advisable to continue efforts in order to reduce dietary exposure to acrylamide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Biological dose estimation of partial body exposures in cervix cancer patients

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Nasazzi, Nora B.; Taja, Maria R.; Roth, B.; Sardi, M.; Menendez, P.

    2000-01-01

    At present, unstable chromosome aberrations analysis in peripheral blood lymphocytes is the most sensitive method to provide a biological estimation of the dose in accidental radiation over exposures. The assessment of the dose is particularly reliable in cases of acute, uniform, whole-body exposures or after irradiation of large parts of the body. However, the scenarios of most radiation accidents result in partial-body exposures or non-uniform dose distribution, leading to a differential exposure of lymphocytes in the body. Inhomogeneity produces a yield of dicentrics, which does not conform to a Poisson distribution, but is generally over dispersed. This arises because those lymphocytes in tissues outside the radiation field will not be damaged. Most of the lymphocytes (80 %) belong to the 'redistributional pool' (lymphatic tissues and other organs) and made recirculate into peripheral blood producing a mixed irradiated and unirradiated population of lymphocytes. So-called over dispersion, with a variance greater than the mean, can be taken as an indication of non-uniform exposure. The main factors operating in vivo partial-body irradiation may be the location and size of the irradiation field and, at high doses, various cellular reactions such as reduced blast transformation, mitotic delay or interphase death may contribute. For partial-body exposures, mathematical-statistical analysis of chromosome aberration data can be performed to derive a dose estimate for the irradiated fraction of the body, been more realistic than to quote a mean equivalent uniform whole body dose. The 'Contaminated Poisson' method of Dolphin or the Qdr method of Sasaki, both based on similar principles, can achieve this. Contaminated Poisson considers the over dispersed distribution of dicentrics among all the cells scored. The observed distribution is considered to be the sum of a Poisson distribution, which represents the irradiated fraction of the body, and the remaining unexposed

  20. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  1. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  2. Exposure to low-dose barium by drinking water causes hearing loss in mice.

    Science.gov (United States)

    Ohgami, Nobutaka; Hori, Sohjiro; Ohgami, Kyoko; Tamura, Haruka; Tsuzuki, Toyonori; Ohnuma, Shoko; Kato, Masashi

    2012-10-01

    We continuously ingest barium as a general element by drinking water and foods in our daily life. Exposure to high-dose barium (>100mg/kg/day) has been shown to cause physiological impairments. Direct administration of barium to inner ears by vascular perfusion has been shown to cause physiological impairments in inner ears. However, the toxic influence of oral exposure to low-dose barium on hearing levels has not been clarified in vivo. We analyzed the toxic influence of oral exposure to low-dose barium on hearing levels and inner ears in mice. We orally administered barium at low doses of 0.14 and 1.4 mg/kg/day to wild-type ICR mice by drinking water. The doses are equivalent to and 10-fold higher than the limit level (0.7 mg/l) of WHO health-based guidelines for drinking water, respectively. After 2-week exposure, hearing levels were measured by auditory brain stem responses and inner ears were morphologically analyzed. After 2-month exposure, tissue distribution of barium was measured by inductively coupled plasma mass spectrometry. Low-dose barium in drinking water caused severe hearing loss in mice. Inner ears including inner and outer hair cells, stria vascularis and spiral ganglion neurons showed severe degeneration. The Barium-administered group showed significantly higher levels of barium in inner ears than those in the control group, while barium levels in bone did not show a significant difference between the two groups. Barium levels in other tissues including the cerebrum, cerebellum, heart, liver and kidney were undetectably low in both groups. Our results demonstrate for the first time that low-dose barium administered by drinking water specifically distributes to inner ears resulting in severe ototoxicity with degeneration of inner ears in mice. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Radiation exposure of radiologists during angiography: Dose measurements outside the lead apron

    International Nuclear Information System (INIS)

    Fischer, H.; Przetak, C.; Teubert, G.; Ewen, K.; Moedder, U.

    1995-01-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r=0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons. (orig.) [de

  4. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  5. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  6. Lyssavirus infection: 'low dose, multiple exposure' in the mouse model.

    Science.gov (United States)

    Banyard, Ashley C; Healy, Derek M; Brookes, Sharon M; Voller, Katja; Hicks, Daniel J; Núñez, Alejandro; Fooks, Anthony R

    2014-03-06

    The European bat lyssaviruses (EBLV-1 and EBLV-2) are zoonotic pathogens present within bat populations across Europe. The maintenance and transmission of lyssaviruses within bat colonies is poorly understood. Cases of repeated isolation of lyssaviruses from bat roosts have raised questions regarding the maintenance and intraspecies transmissibility of these viruses within colonies. Furthermore, the significance of seropositive bats in colonies remains unclear. Due to the protected nature of European bat species, and hence restrictions to working with the natural host for lyssaviruses, this study analysed the outcome following repeat inoculation of low doses of lyssaviruses in a murine model. A standardized dose of virus, EBLV-1, EBLV-2 or a 'street strain' of rabies (RABV), was administered via a peripheral route to attempt to mimic what is hypothesized as natural infection. Each mouse (n=10/virus/group/dilution) received four inoculations, two doses in each footpad over a period of four months, alternating footpad with each inoculation. Mice were tail bled between inoculations to evaluate antibody responses to infection. Mice succumbed to infection after each inoculation with 26.6% of mice developing clinical disease following the initial exposure across all dilutions (RABV, 32.5% (n=13/40); EBLV-1, 35% (n=13/40); EBLV-2, 12.5% (n=5/40)). Interestingly, the lowest dose caused clinical disease in some mice upon first exposure ((RABV, 20% (n=2/10) after first inoculation; RABV, 12.5% (n=1/8) after second inoculation; EBLV-2, 10% (n=1/10) after primary inoculation). Furthermore, five mice developed clinical disease following the second exposure to live virus (RABV, n=1; EBLV-1, n=1; EBLV-2, n=3) although histopathological examination indicated that the primary inoculation was the most probably cause of death due to levels of inflammation and virus antigen distribution observed. All the remaining mice (RABV, n=26; EBLV-1, n=26; EBLV-2, n=29) survived the tertiary and

  7. Application of maximum values for radiation exposure and principles for the calculation of radiation doses

    International Nuclear Information System (INIS)

    2007-08-01

    The guide presents the definitions of equivalent dose and effective dose, the principles for calculating these doses, and instructions for applying their maximum values. The limits (Annual Limit on Intake and Derived Air Concentration) derived from dose limits are also presented for the purpose of monitoring exposure to internal radiation. The calculation of radiation doses caused to a patient from medical research and treatment involving exposure to ionizing radiation is beyond the scope of this ST Guide

  8. Low-Dose Radiation Exposure and Atherosclerosis in ApoE(-/-) Mice

    NARCIS (Netherlands)

    Mitchel, R. E. J.; Hasu, M.; Bugden, M.; Wyatt, H.; Little, M. P.; Gola, A.; Hildebrandt, G.; Priest, N. D.; Whitman, S. C.

    The hypothesis that single low-dose exposures (0.025-0.5 Gy) to low-LET radiation given at either high (about 150 mGy/min) or low (1 mGy/min) dose rate would promote aortic atherosclerosis was tested in female C57BL/6J mice genetically predisposed to this disease (ApoE(-/-)). Mice were exposed

  9. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    Science.gov (United States)

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  10. Identification of Differential Gene Expression Patterns after Acute Exposure to High and Low Doses of Low-LET Ionizing Radiation in a Reconstituted Human Skin Tissue

    Energy Technology Data Exchange (ETDEWEB)

    Tilton, Susan C.; Markillie, Lye Meng; Hays, Spencer; Taylor, Ronald C.; Stenoien, David L.

    2016-11-01

    Our goal here was to identify dose and temporal dependent radiation responses in a complex tissue, reconstituted human skin. Direct sequencing of RNA (RNA-seq) was used to quantify altered transcripts following exposure to 0.1, 2 and 10 Gy of ionizing radiation at 3 and 8 hours. These doses include a low dose in the range of some medical diagnostic procedures (0.1 Gy), a dose typically received during radiotherapy (2.0 Gy) and a lethal dose (10 Gy). These doses could be received after an intentional or accidental radiation exposure and biomarkers are needed to rapidly and accurately triage exposed individuals. A total of 1701 genes were deemed to be significantly affected by high dose radiation exposure with the majority of genes affected at 10 Gy. A group of 29 genes including GDF15, BBC3, PPM1D, FDXR, GADD45A, MDM2, CDKN1A, TP53INP1, CYCSP27, SESN1, SESN2, PCNA, and AEN were similarly altered at both 2 and 10 Gy, but not 0.1 Gy, at multiple time points. A much larger group of up regulated genes, including those involved in inflammatory responses, was significantly altered only after a 10 Gy exposure. At high doses, down regulated genes were associated with cell cycle regulation and exhibited an apparent linear response between 2 and 10 Gy. While only a handful of genes were significantly affected by 0.1 Gy exposure using stringent statistical filters, groups of related genes regulating cell cycle progression and inflammatory responses consistently exhibited opposite trends in their regulation compared to the high dose exposures. Differential regulation of PLK1 signaling at low and high doses was confirmed using qRT-PCR. These results indicate that some alterations in gene expression are qualitatively different at low and high doses of radiation in this model system.

  11. Transuranium element toxicity: dose-response relationships at low exposure levels. Summary and speculative interpretation relative to exposure limits

    International Nuclear Information System (INIS)

    Thompson, R.C.

    1975-01-01

    A summary is given of information on transuranium element toxicity and the correlation of this information with current established exposure limits. It is difficult to calculate a biologically relevant radiation dose from deposited plutonium; it is exposure that must be controlled in order to prevent biological effect, and if the relationship between exposure and effect is known, then radiation dose is of no concern. There are extensive data on the effects of plutonium in bone. Results of studies at the University of Utah indicate that plutonium in beagles may be as much as ten times more toxic than radium. It has been suggested that this toxicity ratio may be even higher in man than in the beagle dog because of differences in surface-to-volume ratios and differences in the rate of burial of surface-deposited plutonium. The present capabilities for extrapolating dose-effect relationships seem to be limited to the setting of upper limits, based on assumptions of linearity and considerations related to natural background

  12. Fruit-flies in low-dose exposure experiments

    International Nuclear Information System (INIS)

    Zajnullin, V.G.; Moskalev, A.A.; Shaposhnikov, M.V.; Sheptyakova, A.I.

    2002-01-01

    In vivo exposure of fruit-flies of Drosophila melanogaster line to low doses provided new data indicating that mechanisms of induced genetic instability are involved in radiation-induced alteration of genotype. It is true for increase of genetic variance due to change in transposition number, for change in adaptation capabilities due to modification of gene expression, and for mutability-associated reparation and apoptosis. (author)

  13. A review of the bystander effect and its implications for low-dose exposure

    International Nuclear Information System (INIS)

    Prise, K.M.; Folkard, M.; Michael, B.D.

    2003-01-01

    Current models for the interaction between ionising radiation and living cells or tissues are based on direct genetic damage produced by energy deposition in cellular DNA. An important observation which has questioned this basic assumption is radiation-induced bystander response, in which cells which have not been directly targeted respond if their neighbours have been exposed. This response predominates at low doses of relevance to radiation risk analysis (<0.2 Gy) and therefore needs to be fully characterised. The development of microbeams, which allow individual cells within populations to be targeted with precise doses of radiation, has provided a useful tool for quantifying this response. The authors' studies have targeted individual human and mouse cells with counted protons and helium ions and monitored neighbouring cells for the production of bystander responses. Bystander responses have been measured after exposures as low as a single proton or helium ion delivered to an individual cell. An important aspect is that these responses saturate with increasing dose to the single target cell, thus the relative roles of direct and indirect (non-targeted) responses change with dose. Studies with multicellular, tissue-based models are providing evidence that bystander responses may have a complex phenotype involving multiple pathways and the overall response may be a balance between multiple signalling processes and responses to radiation exposure. Current models for radiation risk assume a linear non-threshold response and have generally been extrapolated from high-dose exposures. The involvement of competing processes at low doses may have important consequences for understanding the effects of low-dose exposure. (author)

  14. Interpretation of the margin of exposure for genotoxic carcinogens - elicitation of expert knowledge about the form of the dose response curve at human relevant exposures.

    Science.gov (United States)

    Boobis, Alan; Flari, Villie; Gosling, John Paul; Hart, Andy; Craig, Peter; Rushton, Lesley; Idahosa-Taylor, Ehi

    2013-07-01

    The general approach to risk assessment of genotoxic carcinogens has been to advise reduction of exposure to "as low as reasonably achievable/practicable" (ALARA/P). However, whilst this remains the preferred risk management option, it does not provide guidance on the urgency or extent of risk management actions necessary. To address this, the "Margin of Exposure" (MOE) approach has been proposed. The MOE is the ratio between the point of departure for carcinogenesis and estimated human exposure. However, interpretation of the MOE requires implicit or explicit consideration of the shape of the dose-response curve at human relevant exposures. In a structured elicitation exercise, we captured expert opinion on available scientific evidence for low dose-response relationships for genotoxic carcinogens. This allowed assessment of: available evidence for the nature of dose-response relationships at human relevant exposures; the generality of judgments about such dose-response relationships; uncertainties affecting judgments on the nature of such dose-response relationships; and whether this last should differ for different classes of genotoxic carcinogens. Elicitation results reflected the variability in experts' views on the form of the dose-response curve for low dose exposure and major sources of uncertainty affecting the assumption of a linear relationship. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Effect of the European directive on medical exposure on patients doses

    Energy Technology Data Exchange (ETDEWEB)

    Wade, P.; Heaton, B. [Aberdeen Royal Infirmary, Aberdeen (United Kingdom)

    2006-07-01

    implemented, which will be described. Incidents often happen due to a sequence of events and are only identified by vigilant radiology staff. It has been found that hospital doctors are the group of referrers most likely to complete referrals wrongly which may result in the wrong patient being x-rayed. It is also surprising the number of parents who turn up for a child appointment. The selection and use of equipment is now more thoroughly scrutinized, with patient doses playing a more important role. We are encouraged to measure patient doses for common procedures on every x-ray set to develop local Diagnostic Reference Levels (D.R.L.s). Rooms with higher D.R.L.s are identified as a priority for replacement. Whilst the implementation of this Directive has definitely had some effect on identifying wrong referrals and optimising the doses patients receive. It is questionable that the Total Collective Dose for Medical Exposures will be reduced because of the increasing use of CT and PET where individual doses are much larger. This will be discussed further. Also the current vogue for CT being used in private practice for cancer and heart disease screening is likely to undo any dose benefits gained from this legislation. (authors)

  16. Effect of the European directive on medical exposure on patients doses

    International Nuclear Information System (INIS)

    Wade, P.; Heaton, B.

    2006-01-01

    , which will be described. Incidents often happen due to a sequence of events and are only identified by vigilant radiology staff. It has been found that hospital doctors are the group of referrers most likely to complete referrals wrongly which may result in the wrong patient being x-rayed. It is also surprising the number of parents who turn up for a child appointment. The selection and use of equipment is now more thoroughly scrutinized, with patient doses playing a more important role. We are encouraged to measure patient doses for common procedures on every x-ray set to develop local Diagnostic Reference Levels (D.R.L.s). Rooms with higher D.R.L.s are identified as a priority for replacement. Whilst the implementation of this Directive has definitely had some effect on identifying wrong referrals and optimising the doses patients receive. It is questionable that the Total Collective Dose for Medical Exposures will be reduced because of the increasing use of CT and PET where individual doses are much larger. This will be discussed further. Also the current vogue for CT being used in private practice for cancer and heart disease screening is likely to undo any dose benefits gained from this legislation. (authors)

  17. Determinants of personal ultraviolet-radiation exposure doses on a sun holiday

    DEFF Research Database (Denmark)

    Petersen, B; Thieden, E; Philipsen, P A

    2013-01-01

    A great number of journeys to sunny destinations are sold to the Danish population every year. We suspect that this travel considerably increases personal annual ultraviolet-radiation (UVR) exposure doses. This is important because such exposure is the main cause of skin cancer, and studies have...

  18. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  19. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  20. Overview of the use of dose constraints in occupational exposures

    International Nuclear Information System (INIS)

    Bonny, A.

    2013-04-01

    An overview of the use of dose constraints in occupational exposures has been carried out in this project. This was done by reviewing and analyzing some of the operational issues/challenges associated with their implementation and providing suggestions regarding operational objectives and uses of dose constraints.The role of dose constraints in the process of optimisation of radiation protection was described, and explanations provided where necessary in order to avoid the possible situations where dose constraints are misinterpreted or used as a stringent limit. Finally, the identification of potential issues that need to be considered in the implementation and setting of dose constraints for the purposes of occupational radiation protection were discussed. (author)

  1. ASSESSING CHILDREN'S EXPOSURES TO PESTICIDES: AN IMPORTANT APPLICATION OF THE STOCHASTIC HUMAN EXPOSURE AND DOSE SIMULATION MODEL (SHEDS)

    Science.gov (United States)

    Accurately quantifying human exposures and doses of various populations to environmental pollutants is critical for the Agency to assess and manage human health risks. For example, the Food Quality Protection Act of 1996 (FQPA) requires EPA to consider aggregate human exposure ...

  2. Effect of continuous exposure to very low dose rates of gamma rays on life span and neoplasia in mice

    International Nuclear Information System (INIS)

    Tanaka, I.B. III; Tanaka, Satoshi; Ichinohe, Kazuaki; Matsumoto, Tsuneya; Otsu, Hiroshi; Oghiso, Yoichi; Sato, Fumiaki; Matsushita, Satoru

    2008-01-01

    Late effects of continuous exposure to ionizing radiation are potential hazards to workers in radiation facilities as well as to the general public. In the recent years, low-dose-rate and low-dose effects have become a serious concern. Using a total of 4,000 mice, we studied the late biological effects of chronic exposure to low-dose-rate radiation on life span and neoplasia. Two thousand male and 2000 female 8-week-old specific pathogen free (SPF) B6C3F1 mice were randomly divided into 4 groups, one non-irradiated (control) and three irradiated. The irradiated groups were exposed to 137 Cs gamma rays at dose-rates of 21, 1.1 and 0.05 mGy day -1 for approximately 400 days with total doses equivalent to 8000, 400 and 20 mGy, respectively. All mice were kept under SPF conditions until natural death and pathological examination was performed to determine the cause of death. Statistical analyses showed that the life spans of mice of both sexes irradiated with 21 mGy day -1 (P -1 (P 86.7% of all deaths. Compared to the non-irradiated controls, incidences of lethal neoplasms were significantly increased for myeloid leukaemia and hemangiosarcoma in males, soft tissue neoplasms and malignant granulosa cell tumors in females exposed to 21 mGy day -1 . The number of multiple primary neoplasms per mouse was significantly increased in mice irradiated at 21 mGy day -1 . Our results suggest that life shortening in mice continuously exposed to low dose-rate gamma rays is due to early death from a variety of neoplasms and not from increased incidence of specific lethal neoplasms. (author)

  3. A PROBABILISTIC EXPOSURE ASSESSMENT FOR CHILDREN WHO CONTACT CCA-TREATED PLAYSETS AND DECKS USING THE STOCHASTIC HUMAN EXPOSURE AND DOSE SIMULATION (SHEDS) MODEL FOR THE WOOD PRESERVATIVE EXPOSURE SCENARIO

    Science.gov (United States)

    The U.S. Environmental Protection Agency has conducted a probabilistic exposure and dose assessment on the arsenic (As) and chromium (Cr) components of Chromated Copper Arsenate (CCA) using the Stochastic Human Exposure and Dose Simulation model for wood preservatives (SHEDS-Wood...

  4. Professional exposure of medical workers: radiation levels, radiation risk and personal dose monitoring

    International Nuclear Information System (INIS)

    Bai Guang

    2005-01-01

    The application of radiation in the field of medicine is the most active area. Due to the rapid and strong development of intervention radiology at present near 20 years, particularly, the medical workers become a popularize group which most rapid increasing and also receiving the must high of professional exposure dose. Because, inter alias, radiation protection management nag training have not fully follow up, the aware of radioactive protection and appropriate approach have tot fully meet the development and need, the professional exposure dose received by medical workers, especially those being engaged in intervention radiology, are more higher, as well as have not yet fully receiving the complete personal dose monitoring, the medical workers become the population group which should be paid the most attention to. The writer would advice in this paper that all medical workers who being received a professional radiation exposure should pay more attention to the safety and healthy they by is strengthening radiation protection and receiving complete personal dose monitoring. (authors)

  5. N-Acetyl Cysteine does not prevent liver toxicity from chronic low dose plus sub-acute high dose paracetamol exposure in young or old mice

    Science.gov (United States)

    Kane, Alice-Elizabeth; Huizer-Pajkos, Aniko; Mach, John; McKenzie, Catriona; Mitchell, Sarah-Jayne; de Cabo, Rafael; Jones, Brett; Cogger, Victoria; Le Couteur, David G; Hilmer, Sarah-Nicole

    2016-01-01

    Paracetamol is an analgesic commonly used by people of all ages, which is well documented to cause severe hepatotoxicity with acute over-exposures. The risk of hepatotoxicity from non-acute paracetamol exposures is less extensively studied, and this is the exposure most common in older adults. Evidence on the effectiveness of N-acetyl cysteine (NAC) for non-acute paracetamol exposures, in any age group, is lacking. This study aimed to examine the effect of long-term exposure to therapeutic doses of paracetamol and sub-acute paracetamol over-exposure, in young and old mice, and to investigate whether NAC was effective at preventing paracetamol hepatotoxicity induced by these exposures. Young and old male C57BL/6 mice were fed a paracetamol-containing (1.33g/kg food) or control diet for 6 weeks. Mice were then dosed orally 8 times over 3 days with additional paracetamol (250mg/kg) or saline, followed by either one or two doses of oral NAC (1200mg/kg) or saline. Chronic low-dose paracetamol exposure did not cause hepatotoxicity in young or old mice, measured by serum alanine aminotransferase (ALT) elevation, and confirmed by histology and a DNA fragmentation assay. Sub-acute paracetamol exposure caused significant hepatotoxicity in young and old mice, measured by biochemistry (ALT) and histology. Neither a single nor double dose of NAC protected against this toxicity from sub-acute paracetamol in young or old mice. This finding has important clinical implications for treating toxicity due to different paracetamol exposure types in patients of all ages, and implies a need to develop new treatments for sub-acute paracetamol toxicity. PMID:26821200

  6. Calculation of the dose caused by internal radiation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    For the purposes of monitoring radiation exposure it is necessary to determine or to estimate the dose caused by both external and internal radiation. When comparing the value of exposure to the dose limits, account must be taken of the total dose incurred from different sources. This guide explains how to calculate the committed effective dose caused by internal radiation and gives the conversion factors required for the calculation. Application of the maximum values for radiation exposure is dealt with in ST guide 7.2, which also sets out the definitions of the quantities and concepts most commonly used in the monitoring of radiation exposure. The monitoring of exposure and recording of doses are dealt with in ST Guides 7.1 and 7.4.

  7. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  8. Present situation of occupational radiation exposure in nuclear power plants

    International Nuclear Information System (INIS)

    Imabori, Akira

    1979-01-01

    The present situation of the radiation exposure of workers, including both employes and subcontractors, in the nuclear power plants in Japan, is presented. Twenty seven nuclear power reactors in operation and under construction are tabulated with the name, the owner, the electric output and the commissioning year of each plant. The results of exposure of the workers in these plants are shown, classifying the dose rate into less than 0.5 rem, 0.5 - 1.5 rem, 1.5 - 2.5 rem, 2.5 - 5 rem and more than 5 rem, and the workers into employes and subcontractors. It is noted that the exposure dose of the subcontractors occupies about 88% of all exposure dose, and the exposure is concentrated during regular inspection period. The exposure dose of about 80% of the workers is less than 0.5 rem, and no one was irradiated more than 5 rem in a year. The total exposure dose, which has especially the tendency of increasing with extended maintenance period and decreasing during plant operation period, shows also the trend of increasing with the lapse of operation years. As for the point of view of whole exposure dose, the value is 0.06 -- 0.43 man-rem/10 6 kWh in 1976 FY. It is considered to be necessary to grasp the total exposure dose of each worker wandering from one plant to another, and the central registration center for the workers in radioactive environment was established in 1978. The whole exposure dose data of each worker are stored in the central computer in this center. This system is highly appreciated in radiation exposure management. The total exposure dose is related to the rate of utilization of nuclear plants, and it is expected to decrease with the decrease of plant outage. (Nakai, Y.)

  9. Eye lens exposure to medical staff performing electrophysiology procedures: dose assessment and correlation to patient dose

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, Olivera; Bozovic, Predrag; Arandjic, Danijela; Antic, Vojislav; Selakovic, Jovana; Pavlovic, Sinisa

    2016-01-01

    The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 μSv for the first operator, 8.7 μSv for the second operator/nurse and 0.50 μSv for radiographer. Corresponding values for cardiac re-synchronisation therapy procedures were 30, 26 and 2.0 μSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma-area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures. (authors)

  10. Research of protocols for optimization of exposure dose in abdominopelic CT

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dong Hee [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2017-06-15

    This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using CTDIVOL, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In CTDIVOL value, the 2 phase showed 26% decrease in abdomen, 1.8∼59.5% decrease in pelvis for 100∼250 mA, 12.7%∼30% increase in pelvis for 300∼400 mA. Also, DLP value showed 53% decrease in abdomen and 41∼81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200∼ 250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2

  11. interactive effect of cowpea variety, dose and exposure time

    African Journals Online (AJOL)

    ACSS

    variety (V), exposure time (T) and dose (D) on the tolerance of C. maculatus to both plant materials. The effect ... laboratories and institutions of higher education in several West .... Each value is the mean±S.E of 20 cowpea seeds. Means ...

  12. Compliance with public dose limits

    International Nuclear Information System (INIS)

    Mason, G.C.

    1991-01-01

    Radiation, in various forms, is ubiquitous in the environment. Natural background radiation leads to an average radiation exposure for the general population of about 2 mSv per year. The mining and milling of radioactive ores - uranium and mineral sands - may cause a small increase in radiation exposure for some members of the public. Because any such increment in exposure is small compared with a natural exposure that is variable and difficult to quantify accurately, it is not easy to determine what proportion of the total dose received by a member of the public can be attributed to mining and milling activities. Consequently, because public dose limits apply and to those doses caused by human activity, such as mining and milling, the task of demonstrating compliance can be hampered by uncertainty. Some strategies for handling this situation are discussed. While the discussion concentrates on public dose limits, much of it may also be applicable, or adaptable, to occupational exposure. 4 refs., 2 figs

  13. Issues with using radiological exposures as a company performance measure in a low dose environment

    International Nuclear Information System (INIS)

    Wilkins, Richard I.

    2008-01-01

    Full text: Collective and maximum individual doses are two measures commonly used as an indicator for measuring Company performance. There is often an expectation for year on year improvements by optimisation of exposures through improved working methods and modernisation of facilities. Eventually a level of exposure can be reached that is no longer easy to measure which makes meaningful trend analysis difficult. The paper discusses the issues that arose at AWE where the majority of exposures are close the limit of detection for the TLD system used. It details the investigation that was carried out when recorded doses where observed to unexpectedly increase significantly. The paper shows the significant effect of a small change in the background radiation levels that are subtracted for each individual dose measurement. Also discussed is the effect of using TLD dosimeter readers that have undergone recent maintenance and are therefore assessing slightly increased exposures. Compounding the apparent increase in gamma dose a slight change in the manufacturing process for the plastic neutron film in the neutron dosimeters also gave an increased neutron exposure measurement which is detailed. The paper concludes with describing the changes that have been made to better ensure reproducibility of the exposure measurements so that any improvements in Company performance can be shown. It also questions the use of Collective Dose as a performance measure which is commonly misused across the industry. (author)

  14. Suggestion of the manual exposure condition guideline for reducing patient dose in digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Eun Ae [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiologic Technology, Dongnam Health University, Suwon (Korea, Republic of)

    2016-12-15

    The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure , the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13 times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

  15. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  16. The risk equivalent of an exposure to-, versus a dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    The long-term potential carcinogenic effects of low-level exposure (LLE) are addressed. The principal point discussed is linear, no-threshold dose-response curve. That the linear no-threshold, or proportional relationship is widely used is seen in the way in which the values for cancer risk coefficients are expressed - in terms of new cases, per million persons exposed, per year, per unit exposure or dose. This implies that the underlying relationship is proportional, i.e., ''linear, without threshold''. 12 refs., 9 figs., 1 tab

  17. Radiofrequency exposure on fast patrol boats in the Royal Norwegian Navy--an approach to a dose assessment.

    Science.gov (United States)

    Baste, Valborg; Mild, Kjell Hansson; Moen, Bente E

    2010-07-01

    Epidemiological studies related to radiofrequency (RF) electromagnetic fields (EMF) have mainly used crude proxies for exposure, such as job titles, distance to, or use of different equipment emitting RF EMF. The Royal Norwegian Navy (RNoN) has measured RF field emitted from high-frequency antennas and radars on several spots where the crew would most likely be located aboard fast patrol boats (FPB). These boats are small, with short distance between the crew and the equipment emitting RF field. We have described the measured RF exposure aboard FPB and suggested different methods for calculations of total exposure and annual dose. Linear and spatial average in addition to percentage of ICNIRP and squared deviation of ICNIRP has been used. The methods will form the basis of a job exposure matrix where relative differences in exposure between groups of crew members can be used in further epidemiological studies of reproductive health. 2010 Wiley-Liss, Inc.

  18. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  19. Personal exposure to total suspended particulates of adolescents living in Vanderbijlpark, South Africa

    CSIR Research Space (South Africa)

    Terblanche, APS

    1995-06-01

    Full Text Available Personal monitoring of exposure to air pollution is becoming increasingly important in health studies as a method of characterizing total exposure. We monitored the exposure of 31 teenagers to total suspended particulates (TSP) over a 12-hour period...

  20. Whole body exposure to low-dose γ-radiation enhances the antioxidant defense system

    International Nuclear Information System (INIS)

    Pathak, C.M.; Avti, P.K.; Khanduja, K.L.; Sharma, S.C.

    2008-01-01

    It is believed that the extent of cellular damage by low- radiation dose is proportional to the effects observed at high radiation dose as per the Linear-No-Threshold (LNT) hypothesis. However, this notion may not be true at low-dose radiation exposure in the living system. Recent evidence suggest that the living organisms do not respond to ionizing radiations in a linear manner in the low dose range 0.01-0.5Gy and rather restore the homeostasis both in vivo and in vitro by normal physiological mechanisms such as cellular and DNA repair processes, immune reactions, antioxidant defense, adaptive responses, activation of immune functions, stimulation of growth etc. In this study, we have attempted to find the critical radiation dose range and the post irradiation period during which the antioxidant defense systems in the lungs, liver and kidneys remain stimulated in these organs after whole body exposure of the animals to low-dose radiation

  1. Health effects of low dose exposures to external ionizing radiation in the French cohort of nuclear workers CEA-AREVA-EDF - 5287

    International Nuclear Information System (INIS)

    Leuraud, K.; Fournier, L.; Samson, E.; Caer-Lorho, S.; Laurier, D.; Laroche, P.; Le Guen, B.

    2015-01-01

    Populations of nuclear workers are particularly relevant to study health effects of low dose and low dose-rate exposures to ionizing radiation. In France, a cohort of nuclear workers employed by CEA, AREVA NC, or EDF, and badge-monitored for radiation exposure, has been followed-up. Annual exposure to penetrating photons was reconstructed for each worker. Standardized mortality ratios were calculated using national mortality rates as the reference. Estimates of radiation dose-mortality associations were obtained using a linear excess relative risk (ERR) model. A total of 59,004 workers were followed-up between 1968 and 2004, for an average of 25 years. The mean cumulative photons dose was 16.1 mSv. At the end of the follow-up, workers were 56 years old and 6,310 workers had died. A strong healthy worker effect was observed. Positive but imprecise estimates of ERR/Sv were observed for all solid cancers and leukemia excluding chronic lymphocytic leukemia. A significant ERR/Sv was found for myeloid leukemia. This cohort study is the most informative ever conducted in France among nuclear workers. Results confirmed a healthy worker effect due to selection at hiring and health monitoring from occupational medicine. Observed dose-risk relationships were consistent with risks estimated in other studies, even if they remained associated to a large uncertainty. (authors)

  2. An experimental study on total dose effects in SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; He Baoping; Zhang Fengqi; Guo Hongxia; Luo Yinhong; Wang Yuanming; Zhang Keying

    2009-01-01

    In order to study testing methods and find sensitive parameters in total dose effects on SRAM-based FPGA, XC2S100 chips were irradiated by 60 Co γ-rays and tested with two test circuit designs. By analyzing the experimental results, the test flow of configuration RAM and bock RAM was given, and the most sensitive parameter was obtained. The results will be a solid foundation for establishing test specification and evaluation methods of total dose effects on SRAM-based FPGAs. (authors)

  3. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    Science.gov (United States)

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  4. Radiation dose optimization research: Exposure technique approaches in CR imaging – A literature review

    International Nuclear Information System (INIS)

    Seeram, Euclid; Davidson, Rob; Bushong, Stewart; Swan, Hans

    2013-01-01

    The purpose of this paper is to review the literature on exposure technique approaches in Computed Radiography (CR) imaging as a means of radiation dose optimization in CR imaging. Specifically the review assessed three approaches: optimization of kVp; optimization of mAs; and optimization of the Exposure Indicator (EI) in practice. Only papers dating back to 2005 were described in this review. The major themes, patterns, and common findings from the literature reviewed showed that important features are related to radiation dose management strategies for digital radiography include identification of the EI as a dose control mechanism and as a “surrogate for dose management”. In addition the use of the EI has been viewed as an opportunity for dose optimization. Furthermore optimization research has focussed mainly on optimizing the kVp in CR imaging as a means of implementing the ALARA philosophy, and studies have concentrated on mainly chest imaging using different CR systems such as those commercially available from Fuji, Agfa, Kodak, and Konica-Minolta. These studies have produced “conflicting results”. In addition, a common pattern was the use of automatic exposure control (AEC) and the measurement of constant effective dose, and the use of a dose-area product (DAP) meter

  5. A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Daegoo

    International Nuclear Information System (INIS)

    Jo, Gwang Ho; Kang, Yeopng Han; Kim, Bu Sun

    2008-01-01

    Digital imaging for general radiography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  6. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  7. THIDA: code system for calculation of the exposure dose rate around a fusion device

    International Nuclear Information System (INIS)

    Iida, Hiromasa; Igarashi, Masahito.

    1978-12-01

    A code system THIDA has been developed for calculation of the exposure dose rates around a fusion device. It consists of the following: one- and two-dimensional discrete ordinate transport codes; induced activity calculation code; activation chain, activation cross section, radionuclide gamma-ray energy/intensity and gamma-ray group constant files; and gamma ray flux to exposure dose rate conversion coefficients. (author)

  8. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    International Nuclear Information System (INIS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B.L.; Guha, Sujoy K.

    2010-01-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  9. Assessing the carcinogenic potential of low-dose exposures to chemical mixtures in the environment: the challenge ahead.

    Science.gov (United States)

    Goodson, William H; Lowe, Leroy; Carpenter, David O; Gilbertson, Michael; Manaf Ali, Abdul; Lopez de Cerain Salsamendi, Adela; Lasfar, Ahmed; Carnero, Amancio; Azqueta, Amaya; Amedei, Amedeo; Charles, Amelia K; Collins, Andrew R; Ward, Andrew; Salzberg, Anna C; Colacci, Annamaria; Olsen, Ann-Karin; Berg, Arthur; Barclay, Barry J; Zhou, Binhua P; Blanco-Aparicio, Carmen; Baglole, Carolyn J; Dong, Chenfang; Mondello, Chiara; Hsu, Chia-Wen; Naus, Christian C; Yedjou, Clement; Curran, Colleen S; Laird, Dale W; Koch, Daniel C; Carlin, Danielle J; Felsher, Dean W; Roy, Debasish; Brown, Dustin G; Ratovitski, Edward; Ryan, Elizabeth P; Corsini, Emanuela; Rojas, Emilio; Moon, Eun-Yi; Laconi, Ezio; Marongiu, Fabio; Al-Mulla, Fahd; Chiaradonna, Ferdinando; Darroudi, Firouz; Martin, Francis L; Van Schooten, Frederik J; Goldberg, Gary S; Wagemaker, Gerard; Nangami, Gladys N; Calaf, Gloria M; Williams, Graeme; Wolf, Gregory T; Koppen, Gudrun; Brunborg, Gunnar; Lyerly, H Kim; Krishnan, Harini; Ab Hamid, Hasiah; Yasaei, Hemad; Sone, Hideko; Kondoh, Hiroshi; Salem, Hosni K; Hsu, Hsue-Yin; Park, Hyun Ho; Koturbash, Igor; Miousse, Isabelle R; Scovassi, A Ivana; Klaunig, James E; Vondráček, Jan; Raju, Jayadev; Roman, Jesse; Wise, John Pierce; Whitfield, Jonathan R; Woodrick, Jordan; Christopher, Joseph A; Ochieng, Josiah; Martinez-Leal, Juan Fernando; Weisz, Judith; Kravchenko, Julia; Sun, Jun; Prudhomme, Kalan R; Narayanan, Kannan Badri; Cohen-Solal, Karine A; Moorwood, Kim; Gonzalez, Laetitia; Soucek, Laura; Jian, Le; D'Abronzo, Leandro S; Lin, Liang-Tzung; Li, Lin; Gulliver, Linda; McCawley, Lisa J; Memeo, Lorenzo; Vermeulen, Louis; Leyns, Luc; Zhang, Luoping; Valverde, Mahara; Khatami, Mahin; Romano, Maria Fiammetta; Chapellier, Marion; Williams, Marc A; Wade, Mark; Manjili, Masoud H; Lleonart, Matilde E; Xia, Menghang; Gonzalez, Michael J; Karamouzis, Michalis V; Kirsch-Volders, Micheline; Vaccari, Monica; Kuemmerle, Nancy B; Singh, Neetu; Cruickshanks, Nichola; Kleinstreuer, Nicole; van Larebeke, Nik; Ahmed, Nuzhat; Ogunkua, Olugbemiga; Krishnakumar, P K; Vadgama, Pankaj; Marignani, Paola A; Ghosh, Paramita M; Ostrosky-Wegman, Patricia; Thompson, Patricia A; Dent, Paul; Heneberg, Petr; Darbre, Philippa; Sing Leung, Po; Nangia-Makker, Pratima; Cheng, Qiang Shawn; Robey, R Brooks; Al-Temaimi, Rabeah; Roy, Rabindra; Andrade-Vieira, Rafaela; Sinha, Ranjeet K; Mehta, Rekha; Vento, Renza; Di Fiore, Riccardo; Ponce-Cusi, Richard; Dornetshuber-Fleiss, Rita; Nahta, Rita; Castellino, Robert C; Palorini, Roberta; Abd Hamid, Roslida; Langie, Sabine A S; Eltom, Sakina E; Brooks, Samira A; Ryeom, Sandra; Wise, Sandra S; Bay, Sarah N; Harris, Shelley A; Papagerakis, Silvana; Romano, Simona; Pavanello, Sofia; Eriksson, Staffan; Forte, Stefano; Casey, Stephanie C; Luanpitpong, Sudjit; Lee, Tae-Jin; Otsuki, Takemi; Chen, Tao; Massfelder, Thierry; Sanderson, Thomas; Guarnieri, Tiziana; Hultman, Tove; Dormoy, Valérian; Odero-Marah, Valerie; Sabbisetti, Venkata; Maguer-Satta, Veronique; Rathmell, W Kimryn; Engström, Wilhelm; Decker, William K; Bisson, William H; Rojanasakul, Yon; Luqmani, Yunus; Chen, Zhenbang; Hu, Zhiwei

    2015-06-01

    Lifestyle factors are responsible for a considerable portion of cancer incidence worldwide, but credible estimates from the World Health Organization and the International Agency for Research on Cancer (IARC) suggest that the fraction of cancers attributable to toxic environmental exposures is between 7% and 19%. To explore the hypothesis that low-dose exposures to mixtures of chemicals in the environment may be combining to contribute to environmental carcinogenesis, we reviewed 11 hallmark phenotypes of cancer, multiple priority target sites for disruption in each area and prototypical chemical disruptors for all targets, this included dose-response characterizations, evidence of low-dose effects and cross-hallmark effects for all targets and chemicals. In total, 85 examples of chemicals were reviewed for actions on key pathways/mechanisms related to carcinogenesis. Only 15% (13/85) were found to have evidence of a dose-response threshold, whereas 59% (50/85) exerted low-dose effects. No dose-response information was found for the remaining 26% (22/85). Our analysis suggests that the cumulative effects of individual (non-carcinogenic) chemicals acting on different pathways, and a variety of related systems, organs, tissues and cells could plausibly conspire to produce carcinogenic synergies. Additional basic research on carcinogenesis and research focused on low-dose effects of chemical mixtures needs to be rigorously pursued before the merits of this hypothesis can be further advanced. However, the structure of the World Health Organization International Programme on Chemical Safety 'Mode of Action' framework should be revisited as it has inherent weaknesses that are not fully aligned with our current understanding of cancer biology. © The Author 2015. Published by Oxford University Press.

  10. Assessing the carcinogenic potential of low-dose exposures to chemical mixtures in the environment: the challenge ahead

    Science.gov (United States)

    Goodson, William H.; Lowe, Leroy; Carpenter, David O.; Gilbertson, Michael; Manaf Ali, Abdul; Lopez de Cerain Salsamendi, Adela; Lasfar, Ahmed; Carnero, Amancio; Azqueta, Amaya; Amedei, Amedeo; Charles, Amelia K.; Collins, Andrew R.; Ward, Andrew; Salzberg, Anna C.; Colacci, Anna Maria; Olsen, Ann-Karin; Berg, Arthur; Barclay, Barry J.; Zhou, Binhua P.; Blanco-Aparicio, Carmen; Baglole, Carolyn J.; Dong, Chenfang; Mondello, Chiara; Hsu, Chia-Wen; Naus, Christian C.; Yedjou, Clement; Curran, Colleen S.; Laird, Dale W.; Koch, Daniel C.; Carlin, Danielle J.; Felsher, Dean W.; Roy, Debasish; Brown, Dustin G.; Ratovitski, Edward; Ryan, Elizabeth P.; Corsini, Emanuela; Rojas, Emilio; Moon, Eun-Yi; Laconi, Ezio; Marongiu, Fabio; Al-Mulla, Fahd; Chiaradonna, Ferdinando; Darroudi, Firouz; Martin, Francis L.; Van Schooten, Frederik J.; Goldberg, Gary S.; Wagemaker, Gerard; Nangami, Gladys N.; Calaf, Gloria M.; Williams, Graeme P.; Wolf, Gregory T.; Koppen, Gudrun; Brunborg, Gunnar; Lyerly, H. Kim; Krishnan, Harini; Ab Hamid, Hasiah; Yasaei, Hemad; Sone, Hideko; Kondoh, Hiroshi; Salem, Hosni K.; Hsu, Hsue-Yin; Park, Hyun Ho; Koturbash, Igor; Miousse, Isabelle R.; Scovassi, A.Ivana; Klaunig, James E.; Vondráček, Jan; Raju, Jayadev; Roman, Jesse; Wise, John Pierce; Whitfield, Jonathan R.; Woodrick, Jordan; Christopher, Joseph A.; Ochieng, Josiah; Martinez-Leal, Juan Fernando; Weisz, Judith; Kravchenko, Julia; Sun, Jun; Prudhomme, Kalan R.; Narayanan, Kannan Badri; Cohen-Solal, Karine A.; Moorwood, Kim; Gonzalez, Laetitia; Soucek, Laura; Jian, Le; D’Abronzo, Leandro S.; Lin, Liang-Tzung; Li, Lin; Gulliver, Linda; McCawley, Lisa J.; Memeo, Lorenzo; Vermeulen, Louis; Leyns, Luc; Zhang, Luoping; Valverde, Mahara; Khatami, Mahin; Romano, Maria Fiammetta; Chapellier, Marion; Williams, Marc A.; Wade, Mark; Manjili, Masoud H.; Lleonart, Matilde E.; Xia, Menghang; Gonzalez Guzman, Michael J.; Karamouzis, Michalis V.; Kirsch-Volders, Micheline; Vaccari, Monica; Kuemmerle, Nancy B.; Singh, Neetu; Cruickshanks, Nichola; Kleinstreuer, Nicole; van Larebeke, Nik; Ahmed, Nuzhat; Ogunkua, Olugbemiga; Krishnakumar, P.K.; Vadgama, Pankaj; Marignani, Paola A.; Ghosh, Paramita M.; Ostrosky-Wegman, Patricia; Thompson, Patricia A.; Dent, Paul; Heneberg, Petr; Darbre, Philippa; Leung, Po Sing; Nangia-Makker, Pratima; Cheng, Qiang (Shawn); Robey, R.Brooks; Al-Temaimi, Rabeah; Roy, Rabindra; Andrade-Vieira, Rafaela; Sinha, Ranjeet K.; Mehta, Rekha; Vento, Renza; Di Fiore, Riccardo; Ponce-Cusi, Richard; Dornetshuber-Fleiss, Rita; Nahta, Rita; Castellino, Robert C.; Palorini, Roberta; Hamid, Roslida A.; Langie, Sabine A.S.; Eltom, Sakina E.; Brooks, Samira A.; Ryeom, Sandra; Wise, Sandra S.; Bay, Sarah N.; Harris, Shelley A.; Papagerakis, Silvana; Romano, Simona; Pavanello, Sofia; Eriksson, Staffan; Forte, Stefano; Casey, Stephanie C.; Luanpitpong, Sudjit; Lee, Tae-Jin; Otsuki, Takemi; Chen, Tao; Massfelder, Thierry; Sanderson, Thomas; Guarnieri, Tiziana; Hultman, Tove; Dormoy, Valérian; Odero-Marah, Valerie; Sabbisetti, Venkata; Maguer-Satta, Veronique; Rathmell, W.Kimryn; Engström, Wilhelm; Decker, William K.; Bisson, William H.; Rojanasakul, Yon; Luqmani, Yunus; Chen, Zhenbang; Hu, Zhiwei

    2015-01-01

    Lifestyle factors are responsible for a considerable portion of cancer incidence worldwide, but credible estimates from the World Health Organization and the International Agency for Research on Cancer (IARC) suggest that the fraction of cancers attributable to toxic environmental exposures is between 7% and 19%. To explore the hypothesis that low-dose exposures to mixtures of chemicals in the environment may be combining to contribute to environmental carcinogenesis, we reviewed 11 hallmark phenotypes of cancer, multiple priority target sites for disruption in each area and prototypical chemical disruptors for all targets, this included dose-response characterizations, evidence of low-dose effects and cross-hallmark effects for all targets and chemicals. In total, 85 examples of chemicals were reviewed for actions on key pathways/mechanisms related to carcinogenesis. Only 15% (13/85) were found to have evidence of a dose-response threshold, whereas 59% (50/85) exerted low-dose effects. No dose-response information was found for the remaining 26% (22/85). Our analysis suggests that the cumulative effects of individual (non-carcinogenic) chemicals acting on different pathways, and a variety of related systems, organs, tissues and cells could plausibly conspire to produce carcinogenic synergies. Additional basic research on carcinogenesis and research focused on low-dose effects of chemical mixtures needs to be rigorously pursued before the merits of this hypothesis can be further advanced. However, the structure of the World Health Organization International Programme on Chemical Safety ‘Mode of Action’ framework should be revisited as it has inherent weaknesses that are not fully aligned with our current understanding of cancer biology. PMID:26106142

  11. UV dose-effect relationships and current protection exposure standards

    International Nuclear Information System (INIS)

    Singh, M.S.; Campbell, G.W.

    1982-04-01

    In this paper we have attempted to quantify the health effects in man of uv-radiation exposure of wavelengths from 240 nm to 320 nm. Exposure to uv in this region could result in the formation of skin cancer or premature aging in man. The induction of cancer by uv radiation results from changes in genetic material. We have used the DNA action spectrum coupled with the uv skin cancer data available in the literature to derive the dose-effect relationships. The results are compared against the current uv protection standards

  12. Consequences of low dose ionizing radiation exposure on the hippocampal microenvironment.

    Directory of Open Access Journals (Sweden)

    Munjal M Acharya

    Full Text Available The response of the brain to irradiation is complex, involving a multitude of stress inducible pathways that regulate neurotransmission within a dynamic microenvironment. While significant past work has detailed the consequences of CNS radiotherapy following relatively high doses (≥ 45 Gy, few studies have been conducted at much lower doses (≤ 2 Gy, where the response of the CNS (like many other tissues may differ substantially from that expected from linear extrapolations of high dose data. Low dose exposure could elicit radioadaptive modulation of critical CNS processes such as neurogenesis, that provide cellular input into hippocampal circuits known to impact learning and memory. Here we show that mice deficient for chemokine signaling through genetic disruption of the CCR2 receptor exhibit a neuroprotective phenotype. Compared to wild type (WT animals, CCR2 deficiency spared reductions in hippocampal neural progenitor cell survival and stabilized neurogenesis following exposure to low dose irradiation. While radiation-induced changes in microglia levels were not found in WT or CCR2 deficient animals, the number of Iba1+ cells did differ between each genotype at the higher dosing paradigms, suggesting that blockade of this signaling axis could moderate the neuroinflammatory response. Interestingly, changes in proinflammatory gene expression were limited in WT animals, while irradiation caused significant elevations in these markers that were attenuated significantly after radioadaptive dosing paradigms in CCR2 deficient mice. These data point to the importance of chemokine signaling under low dose paradigms, findings of potential significance to those exposed to ionizing radiation under a variety of occupational and/or medical scenarios.

  13. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  14. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  15. Estimating the whole-body exposure annual dose of radiation workers of petroleum nuclear well logging

    International Nuclear Information System (INIS)

    Tian Yizong; Gao Jianzheng; Liu Wenhong

    2006-01-01

    Objective: By imitating experiment of radioactive sources being installed, to estimate the annual whole-body exposure dose of radiation workers of petroleum nuclear determining wells; Methods: To compre the values of the theory, imitating experiment and γ individual dose monitor calculations. Results: The three values measured above tally with one anather. Conclusion: The annual whole-body exposure doses of radiation workers of petroleum nuclear determining wells are no more than 5 mSv. (authors)

  16. Computed tomography for preoperative planning in minimal-invasive total hip arthroplasty: Radiation exposure and cost analysis

    Energy Technology Data Exchange (ETDEWEB)

    Huppertz, Alexander, E-mail: Alexander.Huppertz@charite.de [Imaging Science Institute Charite Berlin, Robert-Koch-Platz 7, D-10115 Berlin (Germany); Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Radmer, Sebastian, E-mail: s.radmer@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany); Asbach, Patrick, E-mail: Patrick.Asbach@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Juran, Ralf, E-mail: ralf.juran@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Schwenke, Carsten, E-mail: carsten.schwenke@scossis.de [Biostatistician, Scossis Statistical Consulting, Zeltinger Str. 58G, D-13465 Berlin (Germany); Diederichs, Gerd, E-mail: gerd.diederichs@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Hamm, Bernd, E-mail: Bernd.Hamm@charite.de [Department of Radiology, Medical Physics, Charite-University Hospitals of Berlin, Chariteplatz 1, D-10117 Berlin (Germany); Sparmann, Martin, E-mail: m.sparmann@immanuel.de [Department of Orthopedic Surgery and Rheumatology, Immanuel-Krankenhaus, Koenigstr. 63, D-14109, Berlin (Germany)

    2011-06-15

    Computed tomography (CT) was used for preoperative planning of minimal-invasive total hip arthroplasty (THA). 92 patients (50 males, 42 females, mean age 59.5 years) with a mean body-mass-index (BMI) of 26.5 kg/m{sup 2} underwent 64-slice CT to depict the pelvis, the knee and the ankle in three independent acquisitions using combined x-, y-, and z-axis tube current modulation. Arthroplasty planning was performed using 3D-Hip Plan (Symbios, Switzerland) and patient radiation dose exposure was determined. The effects of BMI, gender, and contralateral THA on the effective dose were evaluated by an analysis-of-variance. A process-cost-analysis from the hospital perspective was done. All CT examinations were of sufficient image quality for 3D-THA planning. A mean effective dose of 4.0 mSv (SD 0.9 mSv) modeled by the BMI (p < 0.0001) was calculated. The presence of a contralateral THA (9/92 patients; p = 0.15) and the difference between males and females were not significant (p = 0.08). Personnel involved were the radiologist (4 min), the surgeon (16 min), the radiographer (12 min), and administrative personnel (4 min). A CT operation time of 11 min and direct per-patient costs of 52.80 Euro were recorded. Preoperative CT for THA was associated with a slight and justifiable increase of radiation exposure in comparison to conventional radiographs and low per-patient costs.

  17. Effects after prenatal radiation exposures

    International Nuclear Information System (INIS)

    Streffer, C.

    2001-01-01

    The mammalian organism is highly radiosensitive during all prenatal developmental periods. For most effects a dose relationship with a threshold is observed. These threshold doses are generally above the exposures from medical diagnostic procedures. The quality and extent of radiation effects are very much dependent on the developmental stage during which an exposure takes place and on the radiation dose. An exposure during the preimplantation period will cause lethality. Malformations are usually induced after exposures during the major organogenesis. Growth retardation is also possible during the late organogenesis and foetal periods. The lower limits of threshold doses for these effects are in the range of 100 mGy. A radiation exposure during the early foetal period can lead to severe mental retardation and impairment of intelligence. There are very serious effects with radiation doses above 0.3 Gy. Carcinogenesis can apparently occur after radiation exposures during the total prenatal development period. The radiation risk factor up to now has not been clear, but it seems that it is in the range of risk factors for cancer that are observed after exposures during childhood. For radiation doses that are used in radiological diagnostics the risk is zero or very low. A termination of pregnancy after doses below 100 mGy should not be considered. (author)

  18. A systematic review of Bisphenol A "low dose" studies in the context of human exposure: a case for establishing standards for reporting "low-dose" effects of chemicals.

    Science.gov (United States)

    Teeguarden, Justin G; Hanson-Drury, Sesha

    2013-12-01

    Human exposure to the chemical Bisphenol A is almost ubiquitous in surveyed industrialized societies. Structural features similar to estrogen confer the ability of Bisphenol A (BPA) to bind estrogen receptors, giving BPA membership in the group of environmental pollutants called endocrine disruptors. References by scientists, the media, political entities, and non-governmental organizations to many toxicity studies as "low dose" has led to the belief that exposure levels in these studies are similar to humans, implying that BPA is toxic to humans at current exposures. Through systematic, objective comparison of our current, and a previous compilation of the "low-dose" literature to multiple estimates of human external and internal exposure levels, we found that the "low-dose" moniker describes exposures covering 8-12 orders of magnitude, the majority (91-99% of exposures) being greater than the upper bound of human exposure in the general infant, child and adult U.S. Population. "low dose" is therefore a descriptor without specific meaning regarding human exposure. Where human exposure data are available, for BPA and other environmental chemicals, reference to toxicity study exposures by direct comparison to human exposure would be more informative, more objective, and less susceptible to misunderstanding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Sex-specific effects of low-dose gestational estradiol-17β exposure on bone development in porcine offspring

    International Nuclear Information System (INIS)

    Flöter, Veronika L.; Galateanu, Gabriela; Fürst, Rainer W.; Seidlová-Wuttke, Dana; Wuttke, Wolfgang; Möstl, Erich; Hildebrandt, Thomas B.

    2016-01-01

    Highlights: • Sex-specific effects and non-monotonic dose responses were demonstrated after low-dose in utero E2 treatment in offspring. • Alterations in bone parameters were found in prepubertal male but not female offspring. • In postpubertal female offspring, cortical and total cross-sectional area were higher at the femoral midpoint. • In utero E2 treatment did neither significantly affect hormone concentrations nor puberty onset in offspring. • The results substantiate the high sensitivity of developing organisms to exogenous estrogens. - Abstract: Estrogens are important for the bone development and health. Exposure to endocrine disrupting chemicals during the early development has been shown to affect the bone phenotype later in life. Several studies have been performed in rodents, while in larger animals that are important to bridge the gap to humans there is a paucity of data. To this end, the pig as large animal model was used in the present study to assess the influence of gestational estradiol-17β (E2) exposure on the bone development of the prepubertal and adult offspring. Two low doses (0.05 and 10 μg E2/kg body weight) referring to the ‘acceptable daily intake’ (ADI) and the ‘no observed effect level’ (NOEL) as stated for humans, and a high-dose (1000 μg E2/kg body weight), respectively, were fed to the sows every day from insemination until delivery. In the male prepubertal offspring, the ADI dose group had a lower strength strain index (p = 0.002) at the proximal tibia compared to controls, which was determined by peripheral quantitative computed tomography. Prepubertal females were not significantly affected. However, there was a higher cortical cross-sectional area (CSA) (p = 0.03) and total CSA (p = 0.02) at the femur midpoint in the adult female offspring of the NOEL dose group as measured by computed tomography. These effects were independent from plasma hormone concentrations (leptin, IGF1, estrogens), which remained

  20. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  1. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  2. Single exposure simultaneous acquisition of digital and conventional radiographs utilizing unaltered dose

    International Nuclear Information System (INIS)

    Oestmann, J.W.; Greene, R.

    1988-01-01

    We describe the simultaneous acquisition of digital and conventional radiographs with a single standard radiographic exposure. A digitizable storage phosphor (ST Imaging Plate, Fuji) is sandwiched into a radiographic cassette (X-Omatic, Kodak) behind a conventional radiographic film-screen combination (Lanex medium screens, OC film, Kodak). The barium fluorohalide storage phosphor is digitized with a helium-neon laser scanner (TCR 201, Toshiba), and the conventional radiograph is processed in the standard fashion (M7B, Kodak). The storage phosphor is exposed by the 'wasted' radiation normally exiting the back of the film-screen combination (32% of the cassette entrance dose at 141 kVp). At a standard exposure (6.3 mAs), the conventional radiograph is of unaltered quality, and the digital image appears to have an adequate signal-to-noise ratio for chest studies despite the lower exposure dose. This technique produces twin images of identical spatial and temporal registration and avoids the added radiation exposure normally required to carry out comparative studies. (orig.)

  3. Mimicking the effects of spaceflight on bone: Combined effects of disuse and chronic low-dose rate radiation exposure on bone mass in mice

    Science.gov (United States)

    Yu, Kanglun; Doherty, Alison H.; Genik, Paula C.; Gookin, Sara E.; Roteliuk, Danielle M.; Wojda, Samantha J.; Jiang, Zhi-Sheng; McGee-Lawrence, Meghan E.; Weil, Michael M.; Donahue, Seth W.

    2017-11-01

    During spaceflight, crewmembers are subjected to biomechanical and biological challenges including microgravity and radiation. In the skeleton, spaceflight leads to bone loss, increasing the risk of fracture. Studies utilizing hindlimb suspension (HLS) as a ground-based model of spaceflight often neglect the concomitant effects of radiation exposure, and even when radiation is accounted for, it is often delivered at a high-dose rate over a very short period of time, which does not faithfully mimic spaceflight conditions. This study was designed to investigate the skeletal effects of low-dose rate gamma irradiation (8.5 cGy gamma radiation per day for 20 days, amounting to a total dose of 1.7 Gy) when administered simultaneously to disuse from HLS. The goal was to determine whether continuous, low-dose rate radiation administered during disuse would exacerbate bone loss in a murine HLS model. Four groups of 16 week old female C57BL/6 mice were studied: weight bearing + no radiation (WB+NR), HLS + NR, WB + radiation exposure (WB+RAD), and HLS+RAD. Surprisingly, although HLS led to cortical and trabecular bone loss, concurrent radiation exposure did not exacerbate these effects. Our results raise the possibility that mechanical unloading has larger effects on the bone loss that occurs during spaceflight than low-dose rate radiation.

  4. Occupational exposure of phosphate mine workers: airborne radioactivity measurements and dose assessment

    International Nuclear Information System (INIS)

    Khater, Ashraf E.; Hussein, M.A.; Hussein, Mohamed I.

    2004-01-01

    Under the Egyptian program for radiation safety and control, airborne radioactivity measurements and radiological dose assessment were conducted in some phosphate and uranium mines. Abu-Tartor mine is one of the biggest underground phosphate mines in Egypt. Airborne radioactivity, radon ( 222 Rn) and its short-lived decay products (progenies) and thoron ( 220 Rn), were measured in selected locations along the mine. The environmental gamma and workers dose equivalent rate (mSv/y) were measured inside and outside the mine using thermo-luminescence dosimeters (TLD). The results were presented and discussed. The calculated annual effective dose due to airborne radioactivity is the main source of occupational exposure and exceeding the maximum recommended level by ICRP-60 inside the mine tunnels. A number of recommendations are suggested to control the occupational exposures

  5. Environmental aspects and public exposure doses of airborne radioactive effluents from a PWR-power plant

    International Nuclear Information System (INIS)

    Song Miaofa; Zhang Jin; Fu Rongchu; Hu Yinxiu

    1989-04-01

    It is estimated that the environmental aspects and public exposure doses of airborne radioactive effluents from a imaginary 0.3 GW PWR-power plant which sited on the site of a large coalfired power plant estimated before. The major contributor to public exposure is found to be the release of 14 C and the critical pathway is food ingestion. A maximum annual individual body effective dose equivalent of 7.112 x 10 -6 Sv · (GW · a) -1 is found at the point of 0.5 km southeast of the source. The collective dose equivalent in the area around the plant within a radius of 100 km is to be 0.5974 man-Sv · a) -1 . Both maximum individual and collective effective dose equivalents of the PWR-power plant are much lower than those of the coal-fired one. If the ash emission ratio of the latter decreases from 24.6% to 1%, public exposure doses of the two plants would be nearly equal

  6. French population's exposure to ionizing radiations

    International Nuclear Information System (INIS)

    2016-01-01

    This report deals with the exposure of the French population to ionizing radiation. The exposures taken into account are related to cosmic and telluric radiations, to radon, to ingestion of natural radionuclides, to medical imaging and to industrial and military sources. Additionally to the mean effective dose, considered as the macroscopic indicator of the population exposure, the variations of the effective dose for each source of exposure are also presented. Then, the variation of the total effective dose is presented. (authors)

  7. Evaluation of room air cleaners for the reduction of exposure and dose to indoor radon progeny

    International Nuclear Information System (INIS)

    Hopke, P.K.; Jensen, B.; Wasiolek, P.

    1994-01-01

    Since the proximate source of dose to the cells of the bronchial epithelium is the deposited radon progeny, the exposure and resulting dose could be reduced if the radon decay products were effectively removed from the indoor atmosphere. Thus, room air cleaners could be effective in reducing the risks associated with indoor radon. However, because of the short half-life of 218 Po, it grows back quickly and in the altered aerosol conditions that are produced by the presence of an air cleaner, the exposure/dose conditions as well as the magnitude of the dose can be substantially changed. To examine the nature of the exposure of individuals in normally occupied homes and to determine the effect of various types of room air cleaners on the exposure to and dose from the indoor radon progeny, a series of measurements have been made using an automated graded screen array system. Two extended experiments were performed in homes in Arnprior, Ontario and Parishville, NY, in which filtration systems, a positive ion electrostatic precipitator, and ioniser/fan systems have been tested for their ability to remove both airborne radioactivity and particles. In both experiments, measurements were made over one week periods with an air cleaner operating and the distributions of exposure are compared with measurements of the background conditions when no cleaner is functioning. The doses to both basal and secretory cells of the bronchial epithelium in the first eight generations of the bronchus were calculated using the model developed by James and their distributions are compared among the various exposure conditions. In most cases the presence of the air cleaner reduced the exposure to radon progeny. However, the reductions in dose were generally substantially smaller than the reductions in exposure. In the intercomparisons of the two filtration units and the two identical ioniser/fan systems, the units generally behaved in a similar manner. The results of this substantial set of

  8. Relationship medical exposure in X-ray diagnosis and loading factor and film/screen system for reduction exposure dose in Aomori. An analysis based on the results of questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A fact-finding questionnaire survey on medical exposure in Aomori Prefecture was conducted in September 1998. Of the 23 exposed sites in the body investigated, exposure at 17 sites in adults was investigated in terms of the type of high-voltage generator, imaging conditions (X-ray tube voltage, electric current, exposure time, etc.), photosensitive materials and relative photosensitivity, and entrance surface doses. At 6 of the 17 exposed sites, the relationships between these technical conditions and entrance surface doses were analyzed to consider further reduction of medical exposure. The most frequently used high-voltage generators were inverter generators (about 52%). In many institutions, additional filters were utilized for high-voltage imaging of the chest. Highly sensitive green-emission materials were the most frequently used photosensitive materials (73%). These findings indicate that many institutions are attempting to reduce exposure. Entrance surface doses varied greatly among institutions: and a 100-fold difference was observed in exposure to the chest, Martius, and the pelvis. Further efforts to lower entrance surface doses are therefore necessary to reduce medical exposure. Negative correlations were observed between electric voltage, electric current, and exposure time. Examination of the relationships between entrance surface doses, electric current, and exposure time yielded positive correlations. However, the entrance surface doses may not have been properly calculated in some institutions, and examination of the relationship between the relative sensitivity of the sensitive material and entrance surface doses showed great variability in entrance surface doses between institutions. Based on the above results, it is concluded that further reduction of medical exposure is possible, not only by improving the accuracy of X-ray units/devices, but by choosing a more appropriate of conditions to perform radiography. (K.H.)

  9. Experiences with using a concept of organ-dose combination as a basis for practical measures in radiation protection

    International Nuclear Information System (INIS)

    Wernli, C.

    1977-01-01

    The concept of organ-dose combination is presented and its practical consequences for working-place and personnel monitoring and for the improvement of working methods are shown. Two years of practical experience have demonstrated the applicability and usefullness of the concept and have resulted in a better concentration and economization of the monitoring and protection efforts. The values for external total body dose and skin dose, in special cases also those for hand dose and internal contamination, are combined to form a criterion for the total radiation detriment which is easy to use and interpret: each measured external or internal exposure is registered as a fraction of the appropriate maximum permissible annual limit (expressed as dose for external exposures and as activity for incorporations). This fraction is called 'exposure index'. Over one year the sum of all registered 'exposure index' values for an employee must not exceed one. This 'total exposure index' values can also be expressed as an 'effective dose' if its value is multiplied by five rem. While the external body exposures clearly dominate in most departments of EIR, the 'effective doses' in the isotope production department are combinations of different organ doses. 'Low' and 'high risk' groups of employee differ by the relative importance of the four 'effective dose' components: 'low risk group' (effective dose 2 rem): (hand dose, total body dose, incorporation, skin dose). The total value of the 'effective dose' and the relative importance of its components determine the practical radiation protection measures and the appropriate combination and frequency of personnel monitoring for each employee

  10. Cytogenetic biodosimetry to estimate radiation doses received in accidental radiological exposures

    International Nuclear Information System (INIS)

    AIsbeih, Ghazi

    2014-01-01

    The tremendous applications of nuclear technologies in various aspects of life increase the probability of over exposure due to involuntary or premeditated nuclear accidents. National radiation-protection preparedness requires adequate estimate of dose received for efficient medical assistance of victims. Cytogenetic biodosimetry is an ISO and IAEA standardized biotechnology technique. We have established a reference biological dosimetry laboratory to boost the nation's ability to respond to sporadic and mass radiation casualty incidents and to assess the magnitude of radiation overexposure. Accurate calculation of radiation doses received will result in evidence based treatment decisions and better management of valuable emergency resources. It will also contribute to the 'National Radiation Protection Program' by playing a role in nuclear emergency plans. The cytogenetic method is standardized and scalable. In addition to diagnosis of over exposure, it provides triage capability for rapid stratification of patients who need more specialized medical care. It can also detect false positives and false negatives exposure particularly in cases of legal allegations

  11. Establishment of exposure dose assessment laboratory in National Radiation Emergency Medical Center (NREMC)

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jae Ryong; Ha, Wi Ho; Yoon, Seok Won; Han, Eun Ae; Lee, Seung Sook [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-10-15

    As unclear industry grown, 432 of the nuclear power plants are operating and 52 of NPPs are under construction currently. Increasing use of radiation or radioisotopes in the field of industry, medical purpose and research such as non-destructive examination, computed tomography and x-ray, etc. constantly. With use of nuclear or radiation has incidence possibility for example the Fukushima NPP incident, the Goiania accident and the Chernobyl Nuclear accident. Also the risk of terror by radioactive material such as Radiological Dispersal Device(RDD) etc. In Korea, since the 'Law on protection of nuclear facilities and countermeasure for radioactive preparedness was enacted in 2003, the Korean institute of Radiological and Medical Sciences(KIRAMS) was established for the radiation emergency medical response in radiological disaster due to nuclear accident, radioactive terror and so on. Especially National Radiation Emergency Medical Center(NREMC) has the duty that is protect citizens from nuclear, radiological accidents or radiological terrors through the emergency medical preparedness. The NREMC was established by the 39-article law on physical protection of nuclear material and facilities and measures for radiological emergencies. Dose assessment or contamination survey should be performed which provide the radiological information for medical response. For this reason, the NREMC establish and re-organized dose assessment system based on the existing dose assessment system of the NREMC recently. The exposure dose could be measured by physical and biological method. With these two methods, we can have conservative dose assessment result. Therefore the NREMC established the exposure dose assessment laboratory which was re-organized laboratory space and introduced specialized equipment for dose assessment. This paper will report the establishment and operation of exposure dose assessment laboratory for radiological emergency response and discuss how to enhance

  12. Population doses from terrestrial gamma exposure in China

    International Nuclear Information System (INIS)

    Ren, T.; Wang, Z.; Zhu, C.

    1992-01-01

    In order to estimate terrestrial gamma radiation exposure three nationwide surveys have been completed since 1981. The population-weighted outdoor and indoor arithmetic means of gamma dose rate based on momentary dose rate measurements using a NaI(Tl) environmental radiation meter and high-pressure ionisation chamber are, respectively, 80.3 nGy.h -1 and 120 nGy.h -1 . Based on integrating dose measurement using TLD CaSO 4 /Dy they are 67 nGy.h -1 and 89 nGy.h -1 respectively, and based on natural radionuclides concentrations in soil, determined by gamma spectroscopy analyses, they are 72.8 nGy.h -1 and 102 nGy.h -1 , respectively. These surveys were conducted independently by different groups. The best estimations of population-weighted gamma dose rates in China, based on all these surveys, would be 70 nGy.h -1 and 98 nGy.h -1 for outdoors and indoors, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of 232 Th and 40 K in the soil of China are much higher than the world average estimated. (author)

  13. Influence of Exposure to Fractionated Dose of Gamma Radiation and Antioxidants Supplementation to Mice on program cell death induction

    International Nuclear Information System (INIS)

    Hanafi, A.

    2010-01-01

    The previous studies reported that the tumor suppressor protein (P53) is not functioning correctly in most human cancers, and that it plays a crucial role in the prevention of tumor development. This study was designed to evaluate if exposure to fractionated dose of gamma radiation impair function of P53 by the administration of antioxidants. Group of control mice was used. Another groups treated with 3 mg/mouse/day of Antox drug which contains the three main antioxidant vitamins (A, C, and E) together with trace element selenium for 15 days. Another group subjected to 1 Gy of gamma radiation 5 times every other day either alone or combined with the Antox drug supplementation. Hepatic and renal functions were evaluated. Antioxidant markers (MDA and GSH) levels, histopathological changes and P53 expression were recorded in liver and kidney tissues. Animals treated with Antox showed some increase in liver transaminases, non significant changes in total protein and albumin levels, a non significant change in kidney function profiles, a non significant increase in MDA and a significant increase in GSH levels in liver and kidney tissues. However, the exposure of mice to fractionated dose of gamma radiation led to a significant increase in kidney function profiles, AST and ALT activity, a significant decrease in total protein and albumin level, a significant increase in MDA levels and a significant decrease in GSH levels in liver and kidney were observed. Exposure of experimental animals post treatment with Antox drug to fractionated dose of gamma radiation revealed a significant amelioration in liver and kidney function profiles, a highly significant decrease in MDA levels and a significant increase in GSH level in comparison with irradiated group. Histopathological changes in liver and kidney recorded the same alterations observed with the biochemical parameters. P53 expression negatively expressed in normal liver and kidney tissues. However, the exposure of mice to

  14. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  15. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  16. Effect of dose rate and exposure time on the stimulation effect of tube growth of Pinus sylvestris pollen

    International Nuclear Information System (INIS)

    Zelles, L.; Fendrik, I.; Technische Univ. Hannover

    1975-01-01

    The stimulating effect of ionizing radiation in respect to dose rate and exposure time was studied using the tube growth of Pinus silvestris pollen. Stimulation was registered with a small dose (50 rad) supplied at low dose rates (0.5; 1.0; 3.0 and 5.0 rad/sec) and with higher doses (300; 800 and 1,400 rad) supplied at higher dose rates (10; 40 and 50 rad/sec). This suggests that only the exposure time is of importance for radiation-induced stimulation provided that the exposure time does not exceed 100 sec. (orig.) [de

  17. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  18. The effect of dose, dose rate, route of administration, and species on tissue and blood levels of benzene metabolites

    International Nuclear Information System (INIS)

    Henderson, R.F.; Sabourin, P.J.; Bechtold, W.E.; Griffith, W.C.; Medinsky, M.A.; Birnbaum, L.S.; Lucier, G.W.

    1989-01-01

    Studies were completed in F344/N rats and B6C3F 1 mice to determine the effect of dose, dose rate, route of administration, and rodent species on formation of total and individual benzene metabolites. Oral doses of 50 mg/kg or higher saturated the capacity for benzene metabolism in both rats and mice, resulting in an increased proportion of the administered dose being exhaled as benzene. The saturating air concentration for benzene metabolism during 6-hr exposures was between 130 and 900 ppm. At the highest exposure concentration, rats exhaled approximately half of the internal dose retained at the end of the 6-hr exposure as benzene; mice exhaled only 15% as benzene. Mice were able to convert more of the inhaled benzene to metabolites than were rats. In addition, mice metabolized more of the benzene by pathways leading to the putative toxic metabolites, benzoquinone and muconaldehyde, than did rats. In both rats and mice, the effect of increasing dose, administered orally or by inhalation, was to increase the proportion of the total metabolites that were the products of detoxification pathways relative to the products of pathways leading to putative toxic metabolites. This indicates low-affinity, high-capacity pathways for detoxification and high-affinity, low-capacity pathways leading to putative toxic metabolites. If the results of rodent studied performed at high doses were used to assess the health risk at low-dose exposures to benzene, the toxicity of benzene would be underestimated

  19. The concept of the effective dose

    International Nuclear Information System (INIS)

    Jacobi, W.

    1975-01-01

    Irradiation of the human body by external or internal sources leads mostly to a simultaneous exposure of several organs. However, so far no clear and consistent recommendations for the combination of organ doses and the assessment of an exposure limit under such irradiation conditions are available. Following a proposal described in ICRP-publication 14 one possible concept for the combination of organ doses is discussed in this paper. This concept is based on the assumption that at low doses the total radiation detriment to the exposed person is given by the sum of radiation detriments to the single organs. Taking into account a linear dose-risk relationship, the sum of weighted organ doses leads to the definition of an 'Effective Dose'. The applicability and consequences of this 'Effective Dose Concept' are discussed especially with regard to the assessment of the maximum permissible intake of radionuclides into the human body and the combination of external and internal exposure. (orig.) [de

  20. Tritium β-radiation induction of chromosomal damage: a calibration curve for low dose, low dose rate exposures of human cells to tritiated water

    International Nuclear Information System (INIS)

    Morrison, D.P.; Gale, K.L.; Lucas, J.N.

    1997-01-01

    Radiation exposures from tritium contribute to the occupational radiation exposures associated with CANDU reactors. Tritiated water is of particular interest since it is readily taken up by human cells and its elimination from the body, and, consequently, the radiation exposure of the cells, is spread over a period of days. Occupational exposures to tritiated water result in what are effectively chronic β-radiation exposures. The doses and dose rates ordinarily used in the definition of cellular responses to radiation in vitro, for use in biological dosimetry (the assessment of radiation exposures based on the observed levels of changes in the cells of exposed individuals), are usually much higher than for most occupational exposures and involve radiations other than tritium β-rays. As a result, their use in assessing the effects from tritiated water exposures may not be appropriate. We describe here an in vitro calibration curve for chronic tritium β-radiation induction of reciprocal chromosomal translocations in humn peripheral blood lymphocytes (PBLs) for use in biodosimetry. (author)

  1. Chronic low dose radiation exposure and oxidative stress in radiation workers

    International Nuclear Information System (INIS)

    Ali, S.S.; Bhatt, M.B.; Kulkarni, MM.; Rajan, R.; Singh, B.B.; Venkataraman, G.

    1996-01-01

    Free radicals have been implicated in the pathogenesis of several human diseases. In this study free radical stress due to low dose chronic radiation exposures of radiation workers was examined as a possible atherogenic risk factor. Data on lipid profiles, lipid peroxidation and reduced glutathione content in blood indicated an absence of correlation with radiation doses up to 125 mSv. (author). 13 refs., 1 fig

  2. Urinary excretion of total isothiocyanates from cruciferous vegetables shows high dose-response relationship and may be a useful biomarker for isothiocyanate exposure

    DEFF Research Database (Denmark)

    Kristensen, Mette; Krogholm, Kirstine Suszkiewicz; Frederiksen, Hanne

    2007-01-01

    in urine was quanti- fied as the cyclocondensation product of 1,2-bezenedithiol by high performance liquid chromatography. Results The total urinary excretion of ITCs correlated significantly with the two doses of ITC from diets with high or low cruciferous content (r(s) = 0.90, P

  3. Reference methodologies and datasets of ICRP Committee 2 on doses from radiation exposure

    International Nuclear Information System (INIS)

    Berkovskyvl, V.; Harrison, J.D.

    2018-01-01

    A quantitative characterisation of exposures is a core element of the ICRP system of protection of people and the environment from harmful effects of ionizing radiation. Such prospective and retrospective characterisations, or 'dose assessments', are required by international and national safety standards for public, occupational and medical exposures that can occur in various exposure situations

  4. Estimated dose rates to members of the public from external exposure to patients with 131I thyroid treatment

    International Nuclear Information System (INIS)

    Dewji, S.; Bellamy, M.; Leggett, R.; Eckerman, K.; Hertel, N.; Sherbini, S.; Saba, M.

    2015-01-01

    Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ( 131 I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered 131 I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with 131 I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the 131 I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of 131 I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after 131 I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ specific activities of 131 I

  5. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kang, A Ram; Ahn, Sung Min [Dept. of Radiological Science, The Graduate School, Gachon University, Incheon (Korea, Republic of); Lee, In Ja [Dept. of Radiologic technology, Dongnam health University, Suwon (Korea, Republic of)

    2017-09-15

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

  6. Comparison of ESD and major organ absorbed doses of 5 year old standard guidekines and clinical exposure conditions

    International Nuclear Information System (INIS)

    Kang, A Ram; Ahn, Sung Min; Lee, In Ja

    2017-01-01

    Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied

  7. Health Effects of Exposure to Low Dose of Radiation

    International Nuclear Information System (INIS)

    Alatas, Zubaidah

    2003-01-01

    Human beings are exposed to natural radiation from external sources include radionuclides in the earth and cosmic radiation, and by internal radiation from radionuclides, mainly uranium and thorium series, incorporated into the body. Living systems have adapted to the natural levels of radiation and radioactivity. But some industrial practices involving natural resources enhance these radionuclides to a degree that they may pose risk to humans and the environment if they are not controlled. Biological effects of ionizing radiation are the outcomes of physical and chemical processes that occur immediately after the exposure, then followed by biological process in the body. These processes will involve successive changes in the molecular, cellular, tissue and whole organism levels. Any dose of radiation, no matter how small, may produce health effects since even a single ionizing event can result in DNA damage. The damage to DNA in the nucleus is considered to be the main initiating event by which radiation causes damage to cells that results in the development of cancer and hereditary disease. It has also been indicated that cytogenetic damage can occur in cells that receive no direct radiation exposure, known as bystander effects. This paper reviews health risks of low dose radiation exposure to human body causing stochastic effects, i.e. cancer induction in somatic cells and hereditary disease in genetic cells. (author)

  8. Persistent DNA damage after high dose in vivo gamma exposure of minipig skin.

    Directory of Open Access Journals (Sweden)

    Emad A Ahmed

    Full Text Available Exposure to high doses of ionizing radiation (IR can lead to localized radiation injury of the skin and exposed cells suffer dsDNA breaks that may elicit cell death or stochastic changes. Little is known about the DNA damage response after high-dose exposure of the skin. Here, we investigate the cellular and DNA damage response in acutely irradiated minipig skin.IR-induced DNA damage, repair and cellular survival were studied in 15 cm(2 of minipig skin exposed in vivo to ~50 Co-60 γ rays. Skin biopsies of control and 4 h up to 96 days post exposure were investigated for radiation-induced foci (RIF formation using γ-H2AX, 53BP1, and active ATM-p immunofluorescence. High-dose IR induced massive γ-H2AX phosphorylation and high 53BP1 RIF numbers 4 h, 20 h after IR. As time progressed RIF numbers dropped to a low of 3-fold elevated at all subsequent time points. Replicating basal cells (Ki67+ were reduced 3 days post IR followed by increased proliferation and recovery of epidermal cellularity after 28 days.Acute high dose irradiation of minipig epidermis impaired stem cell replication and induced elevated apoptosis from 3 days onward. DNA repair cleared the high numbers of DBSs in skin cells, while RIFs that persisted in <1% cells marked complex and potentially lethal DNA damage up to several weeks after exposure. An elevated frequency of keratinocytes with persistent RIFs may thus serve as indicator of previous acute radiation exposure, which may be useful in the follow up of nuclear or radiological accident scenarios.

  9. A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy

    International Nuclear Information System (INIS)

    Burion, Steve; Funk, Tobias; Speidel, Michael A.

    2013-01-01

    Purpose: Reduction of radiation dose in x-ray imaging has been recognized as a high priority in the medical community. Here the authors show that a regional adaptive exposure method can reduce dose-area product (DAP) in x-ray fluoroscopy. The authors' method is particularly geared toward providing dose savings for the pediatric population. Methods: The scanning beam digital x-ray system uses a large-area x-ray source with 8000 focal spots in combination with a small photon-counting detector. An imaging frame is obtained by acquiring and reconstructing up to 8000 detector images, each viewing only a small portion of the patient. Regional adaptive exposure was implemented by varying the exposure of the detector images depending on the local opacity of the object. A family of phantoms ranging in size from infant to obese adult was imaged in anteroposterior view with and without adaptive exposure. The DAP delivered to each phantom was measured in each case, and noise performance was compared by generating noise arrays to represent regional noise in the images. These noise arrays were generated by dividing the image into regions of about 6 mm 2 , calculating the relative noise in each region, and placing the relative noise value of each region in a one-dimensional array (noise array) sorted from highest to lowest. Dose-area product savings were calculated as the difference between the ratio of DAP with adaptive exposure to DAP without adaptive exposure. The authors modified this value by a correction factor that matches the noise arrays where relative noise is the highest to report a final dose-area product savings. Results: The average dose-area product saving across the phantom family was (42 ± 8)% with the highest dose-area product saving in the child-sized phantom (50%) and the lowest in the phantom mimicking an obese adult (23%). Conclusions: Phantom measurements indicate that a regional adaptive exposure method can produce large DAP savings without compromising

  10. The use of caffeine to assess high dose exposures to ionising radiation by dicentric analysis

    International Nuclear Information System (INIS)

    Pujol, M.; Puig, R.; Caballin, M. R.; Barrios, L.; Barquinero, J. F.

    2012-01-01

    Dicentric analysis is considered as a 'gold standard' method for biological dosimetry. However, due to the radiation-induced mitotic delay or inability to reach mitosis of heavily damaged cells, the analysis of dicentrics is restricted to doses up to 4-5 Gy. For higher doses, the analysis by premature chromosome condensation technique has been proposed. Here, it is presented a preliminary study is presented in which an alternative method to analyse dicentrics after high dose exposures to ionising radiation (IR) is evaluated. The method is based on the effect of caffeine in preventing the G2/M checkpoint allowing damaged cells to reach mitosis. The results obtained indicate that the co-treatment with Colcemide and caffeine increases significantly increases the mitotic index, and hence allows a more feasible analysis of dicentrics. Moreover in the dose range analysed, from 0 to 15 Gy, the dicentric cell distribution followed the Poisson distribution, and a simulated partial-body exposure has been clearly detected. Overall, the results presented here suggest that caffeine has a great potential to be used for dose-assessment after high dose exposure to IR. (authors)

  11. Maintenance hemodialysis patients have high cumulative radiation exposure.

    LENUS (Irish Health Repository)

    Kinsella, Sinead M

    2010-10-01

    Hemodialysis is associated with an increased risk of neoplasms which may result, at least in part, from exposure to ionizing radiation associated with frequent radiographic procedures. In order to estimate the average radiation exposure of those on hemodialysis, we conducted a retrospective study of 100 patients in a university-based dialysis unit followed for a median of 3.4 years. The number and type of radiological procedures were obtained from a central radiology database, and the cumulative effective radiation dose was calculated using standardized, procedure-specific radiation levels. The median annual radiation dose was 6.9 millisieverts (mSv) per patient-year. However, 14 patients had an annual cumulative effective radiation dose over 20 mSv, the upper averaged annual limit for occupational exposure. The median total cumulative effective radiation dose per patient over the study period was 21.7 mSv, in which 13 patients had a total cumulative effective radiation dose over 75 mSv, a value reported to be associated with a 7% increased risk of cancer-related mortality. Two-thirds of the total cumulative effective radiation dose was due to CT scanning. The average radiation exposure was significantly associated with the cause of end-stage renal disease, history of ischemic heart disease, transplant waitlist status, number of in-patient hospital days over follow-up, and death during the study period. These results highlight the substantial exposure to ionizing radiation in hemodialysis patients.

  12. Physiologically based pharmacokinetic rat model for methyl tertiary-butyl ether; comparison of selected dose metrics following various MTBE exposure scenarios used for toxicity and carcinogenicity evaluation

    International Nuclear Information System (INIS)

    Borghoff, Susan J.; Parkinson, Horace; Leavens, Teresa L.

    2010-01-01

    There are a number of cancer and toxicity studies that have been carried out to assess hazard from methyl tertiary-butyl ether (MTBE) exposure via inhalation and oral administration. MTBE has been detected in surface as well as ground water supplies which emphasized the need to assess the risk from exposure via drinking water contamination. This model can now be used to evaluate route-to-route extrapolation issues concerning MTBE exposures but also as a means of comparing potential dose metrics that may provide insight to differences in biological responses observed in rats following different routes of MTBE exposure. Recently an updated rat physiologically based pharmacokinetic (PBPK) model was published that relied on a description of MTBE and its metabolite tertiary-butyl alcohol (TBA) binding to α2u-globulin, a male rat-specific protein. This model was used to predict concentrations of MTBE and TBA in the kidney, a target tissue in the male rat. The objective of this study was to use this model to evaluate the dosimetry of MTBE and TBA in rats following different exposure scenarios, used to evaluate the toxicity and carcinogenicity of MTBE, and compare various dose metrics under these different conditions. Model simulations suggested that although inhalation and drinking water exposures show a similar pattern of MTBE and TBA exposure in the blood and kidney (i.e. concentration-time profiles), the total blood and kidney levels following exposure of MTBE to 7.5 mg/ml MTBE in the drinking water for 90 days is in the same range as administration of an oral dose of 1000 mg/kg MTBE. Evaluation of the dose metrics also supports that a high oral bolus dose (i.e. 1000 mg/kg MTBE) results in a greater percentage of the dose exhaled as MTBE with a lower percent metabolized to TBA as compared to dose of MTBE that is delivered over a longer period of time as in the case of drinking water.

  13. Personal radiofrequency electromagnetic field exposure measurements in Swiss adolescents.

    Science.gov (United States)

    Roser, Katharina; Schoeni, Anna; Struchen, Benjamin; Zahner, Marco; Eeftens, Marloes; Fröhlich, Jürg; Röösli, Martin

    2017-02-01

    Adolescents belong to the heaviest users of wireless communication devices, but little is known about their personal exposure to radiofrequency electromagnetic fields (RF-EMF). The aim of this paper is to describe personal RF-EMF exposure of Swiss adolescents and evaluate exposure relevant factors. Furthermore, personal measurements were used to estimate average contributions of various sources to the total absorbed RF-EMF dose of the brain and the whole body. Personal exposure was measured using a portable RF-EMF measurement device (ExpoM-RF) measuring 13 frequency bands ranging from 470 to 3600MHz. The participants carried the device for three consecutive days and kept a time-activity diary. In total, 90 adolescents aged 13 to 17years participated in the study conducted between May 2013 and April 2014. In addition, personal measurement values were combined with dose calculations for the use of wireless communication devices to quantify the contribution of various RF-EMF sources to the daily RF-EMF dose of adolescents. Main contributors to the total personal RF-EMF measurements of 63.2μW/m 2 (0.15V/m) were exposures from mobile phones (67.2%) and from mobile phone base stations (19.8%). WLAN at school and at home had little impact on the personal measurements (WLAN accounted for 3.5% of total personal measurements). According to the dose calculations, exposure from environmental sources (broadcast transmitters, mobile phone base stations, cordless phone base stations, WLAN access points, and mobile phones in the surroundings) contributed on average 6.0% to the brain dose and 9.0% to the whole-body dose. RF-EMF exposure of adolescents is dominated by their own mobile phone use. Environmental sources such as mobile phone base stations play a minor role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The 1997 determination of the Australian standards of exposure and absorbed dose at 60Co

    International Nuclear Information System (INIS)

    Huntley, R.B.; Boas, J.F.; Van der Gaast, H.

    1998-05-01

    The arrangements for the maintenance of the Australian standards for 60 Co are described in detail. The primary standards are a graphite cavity chamber for exposure/air kerma and a graphite calorimeter for absorbed dose. These secondary standards are described and their responses in corresponding 90 Sr reference sources are reported. Accurate ratios between the Australian Radiation Laboratory (ARL) and Australian Nuclear Science and Technology (ANSTO) 90 Sr reference sources are derived for use in future calibrations. The value of 28.8 years for the half-life of 90 Sr is confirmed. The usefulness of 90 Sr reference source measurements in quality assurance is discussed. The charge sensitivity and linearity of the ANSTO electrometers are reported by two different methods and are compared with previous results. Calibration factors for all the secondary standard ionization chambers are given, in terms of exposure, air kerma and absorbed dose to water. Calibration factors are also given for most of the chambers in terms of absorbed dose to graphite. The methods of deriving the calibration factors are explained in detail, including all the corrections applied to both the primary and secondary standard measurements. Three alternative methods of deriving the absorbed dose to water calibration factors are compared. The reported calibration factors are compared with previous results. Changes in the Australian units of exposure, air kerma and absorbed dose to graphite and water are derived from changes in the corresponding calibration factors. The Australian units of exposure and air kerma have not changed significantly since 1990. The Australian unit of absorbed dose to graphite is now 1.1 % smaller than in 1993 and 1.3 % smaller than in 1990. The Australian unit of absorbed dose to water is now 1.4 % smaller than in 1993, but is only 0.9 % smaller than in 1990. Comparisons of the Australian standards of exposure/air kerma and absorbed dose with those of the Bureau

  15. Radiation exposure dose on persons engaged in radiation-related industries in Korea

    International Nuclear Information System (INIS)

    Lim, Bong Sik

    2006-01-01

    This study investigated the status of radiation exposure doses since the establishment of the 'Regulations on Safety Management of Diagnostic Radiation Generation Device' in January 6, 1995. The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organization, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Among 57,136 men were 40,870 (71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors (22.7%), nurse (2.9%) and others (24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv (limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. The total exposure per worker was significantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided

  16. Biological dosimetry - a Bayesian approach in the presentation of the uncertainty of the estimated dose in cases of exposure to low dose radiation

    International Nuclear Information System (INIS)

    Di Giorgio, Marina; Zaretzky, A.

    2010-01-01

    Biodosimetry laboratory experience has shown that there are limitations in the existing statistical methodology. Statistical difficulties generally occur due to the low number of aberrations leading to large uncertainties for dose estimation. Some problems derived from limitations of the classical statistical methodology, which requires that chromosome aberration yields be considered as something fixed and consequently provides a deterministic dose estimation and associated confidence limits. On the other hand, recipients of biological dosimetry reports, including medical doctors, regulators and the patients themselves may have a limited comprehension of statistics and of informed reports. Thus, the objective of the present paper is to use a Bayesian approach to present the uncertainty on the estimated dose to which a person could be exposed, in the case of low dose (occupational doses) radiation exposure. Such methodology will allow the biodosimetrists to adopt a probabilistic approach for the cytogenetic data analysis. At present, classical statistics allows to produce a confidence interval to report such dose, with a lower limit that could not detach from zero. In this situation it becomes difficult to make decisions as they could impact on the labor activities of the worker if an exposure exceeding the occupational dose limits is inferred. The proposed Bayesian approach is applied to occupational exposure scenario to contribute to take the appropriate radiation protection measures. (authors) [es

  17. Evaluation of secondary exposure doses to transportation and medical personnel in the radiation emergency medicine

    International Nuclear Information System (INIS)

    Kato, Hideki; Suzuki, Shoichi; Koga, Sukehiko; Mukoyama, Takashi; Tomatsu, Hirotaka; Suzuki, Yusuke

    2009-01-01

    Radionuclide contamination is one of the accidents that might occur while carrying out a periodical inspection of nuclear power stations during normal reactor operation. When such an accident occurs, rescue and medical personnel, involved in transporting and treating affected workers run the risk of exposure to secondary radiation. In this study, the ambient dose equivalent rate at a certain distance from the surface of the human body contaminated with typical radioactive corrosion products was calculated. Further, the relationships among the adhesion area, contamination density, and secondary exposure dose were clarified. The secondary exposure dose and permissible working hours in a radiation emergency medicine were estimated by presenting these relationships in the form of a chart and by specifying the contamination levels. (author)

  18. Influence of different exposure modes on image quality and radiation dose in digital mammography

    International Nuclear Information System (INIS)

    Liu Jie; Wang Xia; Li Xiaokang; Liu Peifang

    2013-01-01

    Objective: To evaluate the effect of different exposure modes on radiation dose and image quality in digital mammography, and to explore how to reduce patient's radiation injury by choosing proper exposure mode and exposure conditions without sacrifice image quality. Methods: A breast phantom was exposed by using automatic exposure mode (60 mAs, 28 k/V) and manual exposure modes (37.5 to 70 mAs range, 24 to 32 kV range) respectively. Same oppression thickness and pressure were set for all modes. The average glandular dose (AGD), entrance surface dose (ESD), and image quality score according to American College of Radiology (ACR) criteria were recorded for each image. Kruskal Wallis test was used to compare the image quality scores between automatic and manual modes. All statistic analyses were performed by using SPSS17.0. Results: Compared to automatic exposure mode (60 mAs, 28 k/V), the overall score of image quality of manual modes (45 to 70 mAs range, 26 to 32 kV range) had no significant difference. Both ESD and ACD decreased 26.1% and increased 15.4% when the tube loading was changed from 60 mAs to 45 mAs and 70 mAs respectively. The ESD and ACD decreased 22.6%, 28.2% and increased 47.0%, 62.7% when the tube voltage was changed from 28 kV to 26 kV and 32 kV respectively. Conclusion: When the image quality reaches to a certain level, it will not be raised by a higher photographic condition. Without sacrifice image quality, the tube loading and tube voltage can be manually decreased to reduce radiation dose. (authors)

  19. Trends of the effective dose distribution of occupational exposures in medical and research departments for KIRAMS in Republic of Korea

    International Nuclear Information System (INIS)

    Park, M.; Kim, G. S.; Ji, Y. H.; Jung, M. S.; Kim, K. B.; Jung, H.

    2014-01-01

    This work proposes the basic reference data of occupational dose management and statistical dose distribution with the classification of radiation work groups though analysis of occupational dose distribution. Data on occupational radiation exposure from medical and scientific usage of radiation in Korea Institute of Radiological and Medical Sciences for the years 2002-11 are presented and evaluated with the characteristic tendency of radiation working groups. The results of occupational radiation exposure were measured by personal dosemeters. The monitored occupational exposure dose data were evaluated according to the average effective dose and collective dose. The most annual average effective dose for all occupational radiation workers was under 1 mSv. Considering the dose distribution of each department, most overexposure workers worked in radiopharmaceutical product facilities, nuclear medicine department and radiation oncology department. In addition, no monitored workers were found to have received an occupational exposure over 50 mSv in single year or 100 mSv in this period. Although the trend of occupational exposure was controlled <1 mSv after 2007 and the radiation protection status was sufficient, it was consistently necessary to optimise and reduce the occupational radiation exposure. (authors)

  20. Population doses from terrestrial gamma exposure in China

    Energy Technology Data Exchange (ETDEWEB)

    Ren, T.; Wang, Z.; Zhu, C. (Ministry of Public Health, Beijing, BJ (China))

    1992-01-01

    In order to estimate terrestrial gamma radiation exposure three nationwide surveys have been completed since 1981. The population-weighted outdoor and indoor arithmetic means of gamma dose rate based on momentary dose rate measurements using a NaI(Tl) environmental radiation meter and high-pressure ionisation chamber are, respectively, 80.3 nGy.h[sup -1] and 120 nGy.h[sup -1]. Based on integrating dose measurement using TLD CaSO[sub 4]/Dy they are 67 nGy.h[sup -1] and 89 nGy.h[sup -1] respectively, and based on natural radionuclides concentrations in soil, determined by gamma spectroscopy analyses, they are 72.8 nGy.h[sup -1] and 102 nGy.h[sup -1], respectively. These surveys were conducted independently by different groups. The best estimations of population-weighted gamma dose rates in China, based on all these surveys, would be 70 nGy.h[sup -1] and 98 nGy.h[sup -1] for outdoors and indoors, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of [sup 232]Th and [sup 40]K in the soil of China are much higher than the world average estimated. (author).

  1. Peripubertal Caffeine Exposure Impairs Longitudinal Bone Growth in Immature Male Rats in a Dose- and Time-Dependent Manner.

    Science.gov (United States)

    Choi, Yun-Young; Choi, Yuri; Kim, Jisook; Choi, Hyeonhae; Shin, Jiwon; Roh, Jaesook

    2016-01-01

    This study investigated the dose- and time-dependent effects of caffeine consumption throughout puberty in peripubertal rats. A total of 85 male SD rats were randomly divided into four groups: control and caffeine-fed groups with 20, 60, or 120 mg/kg/day through oral gavage for 10, 20, 30, or 40 days. Caffeine decreased body weight gain and food consumption in a dose- and time-dependent manner, accompanied by a reduction in muscle and body fat. In addition, it caused a shortening and lightening of leg bones and spinal column. The total height of the growth plate decreased sharply at 40 days in the controls, but not in the caffeine-fed groups, and the height of hypertrophic zone in the caffeine-fed groups was lower than in the control. Caffeine increased the height of the secondary spongiosa, whereas parameters related to bone formation, such as bone area ratio, thickness and number of trabeculae, and bone perimeter, were significantly reduced. Furthermore, serum levels of IGF-1, estradiol, and testosterone were also reduced by the dose of caffeine exposure. Our results demonstrate that caffeine consumption can dose- and time-dependently inhibit longitudinal bone growth in immature male rats, possibly by blocking the physiologic changes in body composition and hormones relevant to bone growth.

  2. Chronic cigarette smoke exposure increases the pulmonary retention and radiation dose of 239Pu inhaled as 239PuO2 by F344 rats

    International Nuclear Information System (INIS)

    Finch, G.L.; Lundgren, D.L.; Barr, E.B.; Chen, B.T.; Griffith, W.C.; Hobbs, C.H.; Hoover, M.D.; Nikula, K.J.; Mauderly, J.L.

    1998-01-01

    As a portion of a study to examine how chronic cigarette smoke exposure might alter the risk of lung tumors from inhaled 239 PuO 2 in rats, the effects of smoke exposure on alpha-particle lung dosimetry over the life-span of exposed rats were determined. Male and female rats were exposed to inhaled 239 PuO 2 alone or in combination with cigarette smoke. Animals exposed to filtered air along served as controls for the smoke exposure. Whole-body exposure to mainstream smoke diluted to concentrations of either 100 or 250 mg total particulate matter m -3 began at 6 wk of age and continued for 6 h d -1 , 5 d wk -1 , for 30 mo. A single, pernasal, acute exposure to 239 PuO 2 was given to all rats at 12 wk of age. Exposure to cigarette smoke caused decreased body weight gains in a concentration dependent manner. Lung-to-body weight ratios were increased in smoke-exposed rats. Rats exposed to cigarette smoke before the 239 PuO 2 exposure deposited less 239 Pu in the lung than did controls. Except for male rats exposed to LCS, exposure to smoke retarded the clearance of 239 Pu from the lung compared to control rats through study termination at 870 d after 239 PuO 2 exposure. Radiation doses to lungs were calculated by sex and by exposure group for rats on study for at least 360 d using modeled body weight changes, lung-to-body weight ratios, and standard dosimetric calculations. For both sexes, estimated lifetime radiation doses from the time of 239 PuO 2 exposure to death were 3.8 Gy, 4.4 Gy, or 6.7 Gy for the control, LCS, or HCS exposure groups, respectively. Assuming an approximately linear dose-response relationship between radiation dose and lung neoplasm incidence, approximate increases of 20% or 80% in tumor incidence over controls would be expected in rats exposed to 239 PuO 2 and LCS or 239 PuO 2 and HCS, respectively

  3. Estimation of the total absorbed dose by quartz in retrospective conditions

    International Nuclear Information System (INIS)

    Correcher, V.; Delgado, A.

    2003-01-01

    The estimation of the total absorbed dose is of great interest in areas affected by a radiological accident when no conventional dosimetric systems are available. This paper reports about the usual methodology employed in dose reconstruction from the thermoluminescence (TL) properties of natural quartz, extracted from selected ceramic materials (12 bricks) picked up in the Chernobyl area. It has been possible to evaluate doses under 50mGy after more than 11 years later since the radiological accident happened. The main advance of this fact is the reduction of the commonly accepted limit dose estimation more than 20 times employing luminescence methods. (Author) 11 refs

  4. Present status of brain intravascular surgery and reduction of exposure dose

    International Nuclear Information System (INIS)

    Sato, Kunihiko

    1999-01-01

    Many successful results have been obtained during the progress of angiography of which purpose has been changing from diagnosis to interventional radiography (IVR). The problem involved in IVR is the serious exposure to patients and operating staff. In the field of brain neurosurgery, use of IVR is expanding: e.g., for embolization of sick vasculature, for percutaneous transluminal angioplasty and for intra-arterial administration of therapeutic agents. When the skin doses were measured with thermoluminescence dosimeter (LiF), 409.9 and 2654.4 mGy of exposure were found in cases of 17 diagnoses and 17 IVR, respectively. Reduction of exposure was examined and discussed with angiography QC phantom and testing chart under various imaging conditions. Reduction could be attainable by reduction of fluoroscopy pulse rate and flame, and use of expanding function and filter. For protection of staff, scattering radiation doses and effects of shielding were examined with phantoms and ionization chamber survey meters to see the distribution of the radiation. For protection, it was important to make narrow the irradiation field and to use the shielding tools. (K.H.)

  5. Antipsychotic dose equivalents and dose-years: a standardized method for comparing exposure to different drugs.

    Science.gov (United States)

    Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon

    2010-02-01

    A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  6. Radiation exposure and dose evaluation in intraoral dental radiology

    International Nuclear Information System (INIS)

    Poppe, B.; Looe, H. K.; Pfaffenberger, A.; Eenboom, F.; Chofor, N.; Sering, M.; Ruehmann, A.; Poplawski, A.; Willborn, K.

    2007-01-01

    In this study, dose area product measurements have been performed to propose diagnostic reference levels (DRLs) in intraoral dental radiology. Measurements were carried out at 60 X-ray units for all types of intraoral examinations performed in clinical routine. The third quartile values calculated range from 26.2 to 87.0 mGy cm 2 . The results showed that there exists a large difference between the patient exposures among different dental facilities. It was also observed that dentists working with faster film type or higher tube voltage are not always associated with lower exposure. The study demonstrated the necessity to have the DRLs laid out as guidelines in dental radiology. (authors)

  7. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  8. The Increase in Animal Mortality Risk following Exposure to Sparsely Ionizing Radiation Is Not Linear Quadratic with Dose

    OpenAIRE

    Haley, Benjamin M.; Paunesku, Tatjana; Grdina, David J.; Woloschak, Gayle E.

    2015-01-01

    Introduction The US government regulates allowable radiation exposures relying, in large part, on the seventh report from the committee to estimate the Biological Effect of Ionizing Radiation (BEIR VII), which estimated that most contemporary exposures- protracted or low-dose, carry 1.5 fold less risk of carcinogenesis and mortality per Gy than acute exposures of atomic bomb survivors. This correction is known as the dose and dose rate effectiveness factor for the life span study of atomic bo...

  9. Theoretical considerations for SRAM total-dose hardening

    International Nuclear Information System (INIS)

    Francis, P.; Flandre, D.; Colinge, J.P.

    1995-01-01

    The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented

  10. Radiation exposures for DOE and DOE contractor employees, 1990

    International Nuclear Information System (INIS)

    Smith, M.H.; Hui, T.E.; Millet, W.H.; Scholes, V.A.

    1994-03-01

    This is the 23rd in a series of annual radiation exposure reports published by the Department of Energy (DOE) or its predecessors. This report summarizes the radiation exposures received by both employees and visitors at DOE and DOE contractor facilities during 1990. Trends in radiation exposures are evaluated by comparing the doses received in 1990 to those received in previous years. The significance of the doses is addressed by comparing them to the DOE limits and by correlating the doses to health risks based on risk estimated from expert groups. This report is the third that is based on detailed exposure data for each individual monitored at a DOE facility. Prior to 1988, only summarized data from each facility were available. This report contains information on different types of radiation doses, including total effective, internal, penetrating, shallow, neutron, and extremity doses. It also contains analysis of exposures by age, sex, and occupation of the exposed individuals. This report also continues the precedent established in the Twenty-First (1988) Annual Report by conducting a detailed, one-time review and analysis of a particular topic of interest. The special topic for this report is a comparison of total effective, internal, and extremity dose equivalent values against penetrating dose equivalent values

  11. Radiological dose reconstruction for birds reconciles outcomes of Fukushima with knowledge of dose-effect relationships

    International Nuclear Information System (INIS)

    Garnier-Laplace, Jacqueline; Beaugelin-Seiller, Karine; Della-Vedova, Claire; Metivier, Jean-Michel; Ritz, Christian; Mousseau, Timothy A.; Pape Moeller, Anders

    2015-01-01

    We reconstructed the radiological dose for birds observed at 300 census sites in the 50-km northwest area affected by the accident at the Fukushima Daiichi nuclear power plant over 2011-2014. Substituting the ambient dose rate measured at the census points (from 0.16 to 31 μGy h -1 ) with the dose rate reconstructed for adult birds of each species (from 0.3 to 97 μGy h -1 ), we confirmed that the overall bird abundance at Fukushima decreased with increasing total doses. This relationship was directly consistent with exposure levels found in the literature to induce physiological disturbances in birds. Among the 57 species constituting the observed bird community, we found that 90% were likely chronically exposed at a dose rate that could potentially affect their reproductive success. We quantified a loss of 22.6% of the total number of individuals per increment of one unit log10-transformed total dose (in Gy), over the four-year post-accident period in the explored area. We estimated that a total dose of 0.55 Gy reduced by 50% the total number of birds in the study area over 2011-2014. The data also suggest a significant positive relationship between total dose and species diversity. (authors)

  12. Global DNA methylation responses to low dose radiation exposure

    International Nuclear Information System (INIS)

    Newman, M.R.; Ormsby, R.J.; Blyth, B.J.; Sykes, P.J.; Bezak, E.

    2011-01-01

    Full text: High radiation doses cause breaks in the DNA which are considered the critical lesions in initiation of radiation-induced cancer. However, at very low radiation doses relevant for the general public, the induction of such breaks will be rare, and other changes to the DNA such as DNA methylation which affects gene expression may playa role in radiation responses. We are studying global DNA methylation after low dose radiation exposure to determine if low dose radiation has short- and/or long-term effects on chromatin structure. We developed a sensitive high resolution melt assay to measure the levels of DNA methylation across the mouse genome by analysing a stretch of DNA sequence within Long Interspersed Nuclear Elements-I (LINE I) that comprise a very large proportion of the mouse and human genomes. Our initial results suggest no significant short-term or longterm) changes in global NA methylation after low dose whole-body X-radiation of 10 J1Gyor 10 mGy, with a significant transient increase in NA methylation observed I day after a high dose of I Gy. If the low radiation doses tested are inducing changes in bal DNA methylation, these would appear to be smaller than the variation observed between the sexes and following the general stress of the sham-irradiation procedure itself. This research was funded by the Low Dose Radiation Research Program, Biological and Environmental Research, US DOE, Grant DE-FG02-05ER64104 and MN is the recipient of the FMCF/BHP Dose Radiation Research Scholarship.

  13. Population doses from terrestrial gamma exposure in China

    International Nuclear Information System (INIS)

    Ren, T.; Wang, Z.; Zhu, C.

    1993-01-01

    In order to estimate terrestrial gamma radiation exposures, three nationwide surveys have been completed since 1981. The population weighted outdoor and indoor arithmetic means of gamma dose rates based on momentary measurements using a NaI(T1) environmental radiation meter and a high pressured ionization chamber are 80.3 and 120 nGy.h -1 . The means based on integrating measurements using TLD natural radionuclides concentrations in soil, determined by gamma spectrometry analyses, are 72.8 and 102 nGy.h -1 , respectively. These surveys were conducted independently and equally representative. The best estimation of site-averaged and population weighted gamma dose rates in China, based on all these surveys, would be 70 and 98 nGy.h -1 for indoor and outdoor, respectively. The annual average of effective dose equivalent is 0.56 mSv. These values are higher than the world averages estimated by UNSCEAR. The main reason is that the concentrations of 232 Th and 40 K in soil of China are much higher than the world average estimated. (author). 4 refs, 2 tabs

  14. CalTOX, a multimedia total exposure model for hazardous-waste sites; Part 1, Executive summary

    Energy Technology Data Exchange (ETDEWEB)

    McKone, T.E.

    1993-06-01

    CalTOX has been developed as a spreadsheet model to assist in health-risk assessments that address contaminated soils and the contamination of adjacent air, surface water, sediments, and ground water. The modeling effort includes a multimedia transport and transformation model, exposure scenario models, and efforts to quantify and reduce uncertainty in multimedia, multiple-pathway exposure models. This report provides an overview of the CalTOX model components, lists the objectives of the model, describes the philosophy under which the model was developed, identifies the chemical classes for which the model can be used, and describes critical sensitivities and uncertainties. The multimedia transport and transformation model is a dynamic model that can be used to assess time-varying concentrations of contaminants introduced initially to soil layers or for contaminants released continuously to air or water. This model assists the user in examining how chemical and landscape properties impact both the ultimate route and quantity of human contact. Multimedia, multiple pathway exposure models are used in the CalTOX model to estimate average daily potential doses within a human population in the vicinity of a hazardous substances release site. The exposure models encompass twenty-three exposure pathways. The exposure assessment process consists of relating contaminant concentrations in the multimedia model compartments to contaminant concentrations in the media with which a human population has contact (personal air, tap water, foods, household dusts soils, etc.). The average daily dose is the product of the exposure concentrations in these contact media and an intake or uptake factor that relates the concentrations to the distributions of potential dose within the population.

  15. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  16. Estimated dose rates to members of the public from external exposure to patients with {sup 131}I thyroid treatment

    Energy Technology Data Exchange (ETDEWEB)

    Dewji, S., E-mail: dewjisa@ornl.gov; Bellamy, M.; Leggett, R.; Eckerman, K. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 (United States); Hertel, N. [Oak Ridge National Laboratory, 1 Bethel Valley Road, MS-6335, Oak Ridge, Tennessee 37831 and Georgia Institute of Technology, 770 State Street, Atlanta, Georgia 30332-0745 (United States); Sherbini, S.; Saba, M. [United States Nuclear Regulatory Commission, Washington, DC 20555-0001 (United States)

    2015-04-15

    Purpose: Estimated dose rates that may result from exposure to patients who had been administered iodine-131 ({sup 131}I) as part of medical therapy were calculated. These effective dose rate estimates were compared with simplified assumptions under United States Nuclear Regulatory Commission Regulatory Guide 8.39, which does not consider body tissue attenuation nor time-dependent redistribution and excretion of the administered {sup 131}I. Methods: Dose rates were estimated for members of the public potentially exposed to external irradiation from patients recently treated with {sup 131}I. Tissue attenuation and iodine biokinetics were considered in the patient in a larger comprehensive effort to improve external dose rate estimates. The external dose rate estimates are based on Monte Carlo simulations using the Phantom with Movable Arms and Legs (PIMAL), previously developed by Oak Ridge National Laboratory and the United States Nuclear Regulatory Commission. PIMAL was employed to model the relative positions of the {sup 131}I patient and members of the public in three exposure scenarios: (1) traveling on a bus in a total of six seated or standing permutations, (2) two nursing home cases where a caregiver is seated at 30 cm from the patient’s bedside and a nursing home resident seated 250 cm away from the patient in an adjacent bed, and (3) two hotel cases where the patient and a guest are in adjacent rooms with beds on opposite sides of the common wall, with the patient and guest both in bed and either seated back-to-back or lying head to head. The biokinetic model predictions of the retention and distribution of {sup 131}I in the patient assumed a single voiding of urinary bladder contents that occurred during the trip at 2, 4, or 8 h after {sup 131}I administration for the public transportation cases, continuous first-order voiding for the nursing home cases, and regular periodic voiding at 4, 8, or 12 h after administration for the hotel room cases. Organ

  17. Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure

    International Nuclear Information System (INIS)

    Picano, Eugenio; Vano, Eliseo; Domenici, Luciano; Bottai, Matteo; Thierry-Chef, Isabelle

    2012-01-01

    According to a fundamental law of radiobiology (“Law of Bergonié and Tribondeau”, 1906), the brain is a paradigm of a highly differentiated organ with low mitotic activity, and is thus radio-resistant. This assumption has been challenged by recent evidence discussed in the present review. Ionizing radiation is an established environmental cause of brain cancer. Although direct evidence is lacking in contemporary fluoroscopy due to obvious sample size limitation, limited follow-up time and lack of focused research, anecdotal reports of clusters have appeared in the literature, raising the suspicion that brain cancer may be a professional disease of interventional cardiologists. In addition, although terminally differentiated neurons have reduced or mild proliferative capacity, and are therefore not regarded as critical radiation targets, adult neurogenesis occurs in the dentate gyrus of the hippocampus and the olfactory bulb, and is important for mood, learning/memory and normal olfactory function, whose impairment is a recognized early biomarker of neurodegenerative diseases. The head doses involved in radiotherapy are high, usually above 2 Sv, whereas the low-dose range of professional exposure typically involves lifetime cumulative whole-body exposure in the low-dose range of < 200 mSv, but with head exposure which may (in absence of protection) arrive at a head equivalent dose of 1 to 3 Sv after a professional lifetime (corresponding to a brain equivalent dose around 500 mSv). At this point, a systematic assessment of brain (cancer and non-cancer) effects of chronic low-dose radiation exposure in interventional cardiologists and staff is needed

  18. The special cell effects and somatic consequences of exposure to low dose radiation

    International Nuclear Information System (INIS)

    Regina Fedortseva; Sergei Aleksanin; Eugene Zheleznyakov; Irina Bychkovskaya

    2007-01-01

    Complete text of publication follows. Objective: The experimental data presented in the report put some clarity into the ongoing polemics about possibility of induction of harmful non-carcinogenic effects in human body as a result of exposure to low doses of radiation. The denial of this possibility is based on the fact that traditionally studied genotoxic effects cannot be the cause of this pathology: the incidence of these effects in exposure to low doses of radiation is fairly low; the effects are not overt in critical slowly regenerating tissues, since they can only be morphologically manifested in actively growing cell populations. Methods: Endothelium of myocardial and alveolar capillaries were studied ultra-structurally in 236 rats irradiated by a wide range of X-ray doses (0,25;0,5;2,25;4,5;9;30;48;100) and 28 intact control animals. Studies were conducted during 12-18 months. The material consisted of 2-3 portions from various parts of myocardium and lung. From each portion, sections were prepared, in which all capillary sections were analyzed and ultra-structure of all lining capillary endotheliocytes (their number most often was more than 100) was studied. In each animal the percentage of non-viable endotheliocytes with signs of generalized organoid destruction, damage of plasmalemma and nuclear structures was accounted. Results: Irradiation of rat to low and higher doses caused significant (up to 7 times) increase number of endothelial cells with various ultra-structural damages (from relatively light ones to in the cell death). Even the lowest dose - 0,25 Gy produce an increasing degeneration, intracellular lysis and defects of mitochondria. We found unusual features of postradiational endothelium changes: dose independence, necessity of revealing the long-term, non-mutational cellular effects, massive involvement of cells, early development of the maximum effect already after the low dose irradiation. These special somatic effects, unlike genotoxic

  19. Total Ionizing Dose effects in 130-nm commercial CMOS technologies for HEP experiments

    CERN Document Server

    Gonella, L; Silvestri, M; Gerardin, S; Pantano, D; Re, V; Manghisoni, M; Ratti, L; Ranieri, A

    2007-01-01

    The impact of foundry-to-foundry variability and bias conditions during irradiation on the Total Ionizing Dose (TID) response of commercial 130-nm CMOS technologies have been investigated for applications in High Energy Physics (HEP) experiments. n- and p-channel MOSFETs from three different manufacturers have been irradiated with X-rays up to more than 100 Mrad (SiO2). Even though the effects of TID are qualitatively similar, the amount of degradation is shown to vary considerably from foundry to foundry, probably depending on the processing of the STI oxide and/or doping profile in the substrate. The bias during irradiation showed to have a strong impact as well on the TID response, proving that exposure at worst case bias conditions largely overestimates the degradation a device may experience during its lifetime. Overall, our results increase the confidence that 130-nm CMOS technologies can be used in future HEP experiments even without Hardness-By-Design solutions, provided that constant monitoring of th...

  20. Individual dose and exposure of Italian children to ultrafine particles.

    Science.gov (United States)

    Buonanno, G; Marini, S; Morawska, L; Fuoco, F C

    2012-11-01

    Time-activity patterns and the airborne pollutant concentrations encountered by children each day are an important determinant of individual exposure to airborne particles. This is demonstrated in this work by using hand-held devices to measure the real-time individual exposure of more than 100 children aged 8-11 years to particle number concentrations and average particle diameter, as well as alveolar and tracheobronchial deposited surface area concentration. A GPS-logger and activity diaries were also used to give explanation to the measurement results. Children were divided in three sample groups: two groups comprised of urban schools (school time from 8:30 am to 1:30 pm) with lunch and dinner at home, and the third group of a rural school with only dinner at home. The mean individual exposure to particle number concentration was found to differ between the three groups, ranging from 6.2 × 10(4)part.cm(-3) for children attending one urban school to 1.6 × 10(4)part.cm(-3) for the rural school. The corresponding daily alveolar deposited surface area dose varied from about 1.7 × 10(3)mm(2) for urban schools to 6.0 × 10(2)mm(2) for the rural school. For all of the children monitored, the lowest particle number concentrations are found during sleeping time and the highest were found during eating time. With regard to alveolar deposited surface area dose, a child's home was the major contributor (about 70%), with school contributing about 17% for urban schools and 27% for the rural school. An important contribution arises from the cooking/eating time spent at home, which accounted for approximately 20% of overall exposure, corresponding to more than 200 mm(2). These activities represent the highest dose received per time unit, with very high values also encountered by children with a fireplace at home, as well as those that spend considerable time stuck in traffic jams. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10 -5 Gy) per 1,000 mR (258 μC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicists who can make the calculations immediately

  2. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10(-5) Gy) per 1,000 mR (258 microC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicians who can make the calculations immediately

  3. The use of total detriment in radiation protection and its potential extension to other hazards

    International Nuclear Information System (INIS)

    Johnson, J.R.; Stansbury, P.S.; Selby, J.M.

    1991-10-01

    Before publication of the 1977 recommendations of the International Commission on Radiological Protection (ICRP), radiation protection standards were based on dose limits to single organs. These dose limits were only loosely linked to the expected effects in the first two generations from gonadal doses and to the risk of fatal cancer from doses to specific organs. In 1977, the ICRP recommended the use of the ''effective dose equivalent (EDE),'' which is a method of summing the doses (weighted with relative risk coefficients) to all organs and tissues, and recommended an annual limit for EDE. Since the 1977 recommendations were published, a ''total risk'' or total detriment approach has been extended to include nonfatal cancers and genetic effects for all subsequent generations, i.e., the total health detriment from low doses of ionizing radiation. This paper discusses the development of this total health detriment from ionizing radiation exposures, and explores potential methods for using it with other hazards (such as exposures to other physical agents, hazardous chemicals, and fatal and nonfatal accidents) in calculating the total detriment to a worker

  4. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  5. Expression of cytoskeletal and matrix genes following exposure to ionizing radiation: Dose-rate effects and protein synthesis requirements

    International Nuclear Information System (INIS)

    Woloschak, G.E.

    1994-01-01

    Experiments were designed to examine the effects Of radiation dose-rate and of the protein synthesis inhibitor cycloheximide on expression of cytoskeletal elements (γ- and β-actin and α-tubulin) and matrix elements (fibronectin) in Syrian hamster embryo cells. Past work from our laboratory had already demonstrated optimum time points and doses for examination of radiation effects on accumulation of specific transcripts. Our results here demonstrated little effect of dose-rate for JANUS fission spectrum neutrons when comparing expression of either α-tubulin or fibronectin genes. Past work had already documented similar results for expression of actin transcripts. Effects of cycloheximide revealed that cycloheximide repressed accumulation of α-tubulin following exposure to high dose-rate neutrons or γ rays; this did not occur following similar low dose-rate exposure. (2) Cycloheximide did not affect accumulation of MRNA for actin genes; and that cycloheximide abrogated the moderate induction of fibronectin-mRNA which occurred following exposure to γ rays and high dose-rate neutrons. These results suggest a role for labile proteins in the maintenance of α-tubulin and fibronectin MRNA accumulation following exposure to ionizing radiation. in addition, they suggest that the cellular/molecular response to low dose-rate neutrons may be different from the response to high dose-rate neutrons

  6. The usefulness of Al face block fabrication for reducing exposure dose of thyroid glands in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Eun Ae [Dept. of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, In Ja [Dept. of Radiologic Technology, Dongnam Health College, Suwon (Korea, Republic of)

    2013-03-15

    Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65 cm, 28 kVp, and 63 mAs. The measuring instrument was Flukes Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients anxiety during breast imaging. The Face Block is expected to improve patients satisfaction and contribute to reducing patients exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

  7. Diagnostic radiation exposure in pediatric trauma patients.

    Science.gov (United States)

    Brunetti, Marissa A; Mahesh, Mahadevappa; Nabaweesi, Rosemary; Locke, Paul; Ziegfeld, Susan; Brown, Robert

    2011-02-01

    The amount of imaging studies performed for disease diagnosis has been rapidly increasing. We examined the amount of radiation exposure that pediatric trauma patients receive because they are an at-risk population. Our hypothesis was that pediatric trauma patients are exposed to high levels of radiation during a single hospital visit. Retrospective review of children who presented to Johns Hopkins Pediatric Trauma Center from July 1, 2004, to June 30, 2005. Radiographic studies were recorded for each patient and doses were calculated to give a total effective dose of radiation. All radiographic studies that each child received during evaluation, including any associated hospital admission, were included. A total of 945 children were evaluated during the study year. A total of 719 children were included in the analysis. Mean age was 7.8 (±4.6) years. Four thousand six hundred three radiographic studies were performed; 1,457 were computed tomography (CT) studies (31.7%). Average radiation dose was 12.8 (±12) mSv. We found that while CT accounted for only 31.7% of the radiologic studies performed, it accounted for 91% of the total radiation dose. Mean dose for admitted children was 17.9 (±13.8) mSv. Mean dose for discharged children was 8.4 (±7.8) mSv (pcumulative radiation exposure can be high. In young children with relatively long life spans, the benefit of each imaging study and the cumulative radiation dose should be weighed against the long-term risks of increased exposure.

  8. A Dose-Response Relationship between Organic Mercury Exposure from Thimerosal-Containing Vaccines and Neurodevelopmental Disorders

    Directory of Open Access Journals (Sweden)

    David A. Geier

    2014-09-01

    Full Text Available A hypothesis testing case-control study evaluated concerns about the toxic effects of organic-mercury (Hg exposure from thimerosal-containing (49.55% Hg by weight vaccines on the risk of neurodevelopmental disorders (NDs. Automated medical records were examined to identify cases and controls enrolled from their date-of-birth (1991–2000 in the Vaccine Safety Datalink (VSD project. ND cases were diagnosed with pervasive developmental disorder (PDD, specific developmental delay, tic disorder or hyperkinetic syndrome of childhood. In addition, putative non-thimerosal-related outcomes of febrile seizure, failure to thrive and cerebral degenerations were examined. The cumulative total dose of Hg exposure from thimerosal-containing hepatitis B vaccine (T-HBV administered within the first six months of life was calculated. On a per microgram of organic-Hg basis, PDD (odds ratio (OR = 1.054, specific developmental delay (OR = 1.035, tic disorder (OR = 1.034 and hyperkinetic syndrome of childhood (OR = 1.05 cases were significantly more likely than controls to receive increased organic-Hg exposure. By contrast, none of the non-thimerosal related outcomes were significantly more likely than the controls to have received increased organic-Hg exposure. Routine childhood vaccination may be an important public health tool to reduce infectious disease-associated morbidity/mortality, but the present study significantly associates organic-Hg exposure from T-HBV with an increased risk of an ND diagnosis.

  9. Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation

    Science.gov (United States)

    Han, Hao; Gao, Hao; Xing, Lei

    2017-08-01

    Excessive radiation exposure is still a major concern in 4D cone-beam computed tomography (4D-CBCT) due to its prolonged scanning duration. Radiation dose can be effectively reduced by either under-sampling the x-ray projections or reducing the x-ray flux. However, 4D-CBCT reconstruction under such low-dose protocols is prone to image artifacts and noise. In this work, we propose a novel joint regularization-based iterative reconstruction method for low-dose 4D-CBCT. To tackle the under-sampling problem, we employ spatiotemporal tensor framelet (STF) regularization to take advantage of the spatiotemporal coherence of the patient anatomy in 4D images. To simultaneously suppress the image noise caused by photon starvation, we also incorporate spatiotemporal nonlocal total variation (SNTV) regularization to make use of the nonlocal self-recursiveness of anatomical structures in the spatial and temporal domains. Under the joint STF-SNTV regularization, the proposed iterative reconstruction approach is evaluated first using two digital phantoms and then using physical experiment data in the low-dose context of both under-sampled and noisy projections. Compared with existing approaches via either STF or SNTV regularization alone, the presented hybrid approach achieves improved image quality, and is particularly effective for the reconstruction of low-dose 4D-CBCT data that are not only sparse but noisy.

  10. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    International Nuclear Information System (INIS)

    Veinot, K.G.; Dewji, S.A.; Hiller, M.M.; Eckerman, K.F.; Easterly, C.E.

    2017-01-01

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133. (orig.)

  11. Organ and effective dose rate coefficients for submersion exposure in occupational settings

    Energy Technology Data Exchange (ETDEWEB)

    Veinot, K.G. [Easterly Scientific, Knoxville, TN (United States); Y-12 National Security Complex, Oak Ridge, TN (United States); Dewji, S.A.; Hiller, M.M. [Center for Radiation Protection Knowledge, Oak Ridge National Laboratory, Oak Ridge, TN (United States); Eckerman, K.F.; Easterly, C.E. [Easterly Scientific, Knoxville, TN (United States)

    2017-11-15

    External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133. (orig.)

  12. Occupational exposures and the case for reducing dose limits

    International Nuclear Information System (INIS)

    Gee, David

    1987-01-01

    This chapter describes the General, Municipal, Boilermakers and Allied Trades Union approach to all harmful agents encountered in either the workplace or the general environment; summarizes current radiation exposures in the UK and their arguments for a five-fold reduction in dose limits; and concludes with a summary of the only agreed compensation scheme in the world for radiation-induced cancer amongst workers. (author)

  13. The total dose effects on the 1/f noise of deep submicron CMOS transistors

    International Nuclear Information System (INIS)

    Hu Rongbin; Wang Yuxin; Lu Wu

    2014-01-01

    Using 0.18 μm CMOS transistors, the total dose effects on the 1/f noise of deep-submicron CMOS transistors are studied for the first time in mainland China. From the experimental results and the theoretic analysis, we realize that total dose radiation causes a lot of trapped positive charges in STI (shallow trench isolation) SiO 2 layers, which induces a current leakage passage, increasing the 1/f noise power of CMOS transistors. In addition, we design some radiation-hardness structures on the CMOS transistors and the experimental results show that, until the total dose achieves 750 krad, the 1/f noise power of the radiation-hardness CMOS transistors remains unchanged, which proves our conclusion. (semiconductor devices)

  14. Medical exposure and the effects of radiation

    International Nuclear Information System (INIS)

    Okuyama, Chio

    2011-01-01

    Radiation gives cracks to genes. The influence is divided into deterministic effect with a threshold value, and the stochastic effect (tumor and genetic effect) which increases according to the exposure amount. Although we are put to various non-artificial radiations, which we cannot be avoided, on the earth, the contamination by artificial radiation can be defended. Artificial radioactive exposure includes medical exposure and non-medical exposure for example by nuclear power plant. As to medical examinations using radiation, the inquiry about the radiation exposure is increasing after the occurrence of the first nuclear power plant disaster of Fukushima. While concern about non-medical radioactive exposure increases, the uneasiness to medical irradiation is also increasing. The dose limit by artificial radioactive exposure other than medical exposure is set up in order to prevent the influence on the health. While the dose limit of the public exposure is set to the lower value than the total dose of non-artificial exposure concerning of a safety margin for all people, the dose limit of medical exposure is not defined, since it is thought that medical irradiation has a benefit for those who receive irradiation. Making an effort to decrease the radiation dose in performing the best medical treatment is the responsibility with which we are burdened. (author)

  15. Phthalate exposure, even below US EPA reference doses, was associated with semen quality and reproductive hormones: Prospective MARHCS study in general population.

    Science.gov (United States)

    Chen, Qing; Yang, Huan; Zhou, Niya; Sun, Lei; Bao, Huaqiong; Tan, Lu; Chen, Hongqiang; Ling, Xi; Zhang, Guowei; Huang, Linping; Li, Lianbing; Ma, Mingfu; Yang, Hao; Wang, Xiaogang; Zou, Peng; Peng, Kaige; Liu, Taixiu; Shi, Xiefei; Feng, Dejian; Zhou, Ziyuan; Ao, Lin; Cui, Zhihong; Cao, Jia

    2017-07-01

    Environment-Protection-Agency Reference Doses (EPA RfDs) for phthalate intakes are based on limited evidence, especially regarding low-dose male-reproductive toxicity. This study investigates the association between phthalate exposure and semen parameters and reproductive hormones in a general population with low phthalate exposure compared to the EPA RfDs. The MARHCS (Male-Reproductive-Health-in-Chongqing-College-Students) cohort recruited 796 male students, who experienced a relocation of campuses and shifting environmental exposure. Urine, semen and blood before and after the relocation was collected and investigated for: (1) the associations between 13 urinary phthalate metabolites and 11 semen/hormone outcomes (five semen parameters including semen volume, sperm concentration, total sperm number, progressive motility, normal morphology) and six serum reproductive hormones including estradiol, follicle-stimulating hormone, luteinizing hormone, prolactin, progesterone, testosterone; (2) re-analysis of the metabolite-outcome associations in the subjects with estimated phthalate intakes below the RfDs; (3) a change in phthalate metabolites and change in semen/hormone outcomes after the relocation; (4) the association between these changes. (1) All but two semen/hormone outcomes were associated with at least one phthalate metabolite, e.g., each quartile monoethyl phthalate was associated with a 5.3%, 5.7% and 2.6% decrease of sperm concentration, total sperm number and progressive motility respectively. (2) In the subjects with phthalate intakes below the RfDs, these metabolite-outcome associations remained significant. (3) All metabolites except mono(2-ethylhexyl) phthalate declined after relocation (Phormone increased (by 5.9%, 25.0%, 34.2% and 10.0%) and testosterone decreased (by 7.0%). (4) The changes in semen volume, normal morphology, estradiol and testosterone, but not the change in luteinizing hormone after relocation, were associated with the changes in

  16. From dust to dose: Effects of forest disturbance on increased inhalation exposure

    International Nuclear Information System (INIS)

    Whicker, Jeffrey J.; Pinder, John E.; Breshears, David D.; Eberhart, Craig F.

    2006-01-01

    Ecosystem disturbances that remove vegetation and disturb surface soils are major causes of excessive soil erosion and can result in accelerated transport of soils contaminated with hazardous materials. Accelerated wind erosion in disturbed lands that are contaminated is of particular concern because of potential increased inhalation exposure, yet measurements regarding these relationships are lacking. The importance of this was highlighted when, in May of 2000, the Cerro Grande fire burned over roughly 30% of Los Alamos National Laboratory (LANL), mostly in ponderosa pine (Pinus ponderosa) forest, and through areas with soils containing contaminants, particularly excess depleted and natural uranium. Additionally, post-fire thinning was performed in burned and unburned forests on about 25% of LANL land. The first goal of this study was to assess the potential for increased inhalation dose from uranium contaminated soils via wind-driven resuspension of soil following the Cerro Grande Fire and subsequent forest thinning. This was done through analysis of post-disturbance measurements of uranium air concentrations and their relationships with wind velocity and seasonal vegetation cover. We found a 14% average increase in uranium air concentrations at LANL perimeter locations after the fire, and the greatest air concentrations occurred during the months of April-June when wind velocities are highest, no snow cover, and low vegetation cover. The second goal was to develop a methodology to assess the relative contribution of each disturbance type towards increasing public and worker exposure to these resuspended soils. Measurements of wind-driven dust flux in severely burned, moderately burned, thinned, and unburned/unthinned forest areas were used to assess horizontal dust flux (HDF) in these areas. Using empirically derived relationships between measurements of HDF and respirible dust, coupled with onsite uranium soil concentrations, we estimate relative increases in

  17. System composition and operation of exposure dose registration and control system (Final report)

    International Nuclear Information System (INIS)

    1978-01-01

    Since November, 1976, the committee concerning the investigation of exposure dose registration and control system for employees in nuclear industries has discussed on the exposure dose registration and control system, issued the interim report (outline) in April, 1977, and continued to investigate the details organizing the working group. Here, the final report is presented. It describes first on the definition of the terms used and the basic concept of the exposure dose registration and control system, in which the name of that organization is decided as ''Central Registration Office for Radiation Works'', Radiation Influence Association, the foundational juridical person. Next, the works to be performed in the Center and nuclear energy enterprises are explained. The items concerning the business management at the time of practical execution are the major part of the report, and are over 22 items. These include the registration business, the official reporting business, inquiry and answer business about career, change and revision, and computer processing system. As the temporary measures for transfer ring to the new system, 10 items are also provided. Supplementary explanation of 9 important items is given in the appendix. (Wakatsuki, Y.)

  18. Biological effects of low-dose ionizing radiation exposure; Biologische Wirkungen niedriger Dosen ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Reinoehl-Kompa, Sabine; Baldauf, Daniela; Heller, Horst (comps.)

    2009-07-01

    The report on the meeting of the Strahlenschutzkommission 2007 concerning biological effects of low-dose ionizing radiation exposure includes the following contributions: Adaptive response. The importance of DNA damage mechanisms for the biological efficiency of low-energy photons. Radiation effects in mammography: the relative biological radiation effects of low-energy photons. Radiation-induced cataracts. Carcinomas following prenatal radiation exposure. Intercellular apoptosis induction and low-dose irradiation: possible consequences for the oncogenesis control. Mechanistic models for the carcinogenesis with radiation-induced cell inactivation: application to all solid tumors in the Japanese atomic bomb survivors. Microarrays at low radiation doses. Mouse models for the analysis of biological effects of low-dose ionizing radiation. The bystander effect: observations, mechanisms and implications. Lung carcinoma risk of Majak workers - modeling of carcinogenesis and the bystander effect. Microbeam studies in radiation biology - an overview. Carcinogenesis models with radiation-induced genomic instability. Application to two epidemiological cohorts.

  19. Radiation exposure of employees in nuclear fuel facilities in fiscal 1982

    International Nuclear Information System (INIS)

    1984-01-01

    The enterprises of nuclear fuel refining, fabrication, reprocessing and usage are obligated by law to keep the radiation exposure dose of the employees below the permissible level. The radiation exposure dose in the respective enterprises in the fiscal year 1982 is summarized in a table as follows: radiation exposure dose distribution, the number of employees, total exposure dose, and average dose. The radiation exposure dose was all well below the permissible level. The enterprises covered were one refining (Power Reactor and Nuclear Fuel Development Corporation), five fabrication (Mitsubishi Nuclear Fuel Co., Ltd., etc.), one reprocessing (Power Reactor and Nuclear Fuel Development Corporation), and ten usage (Power Reactor and Nuclear Fuel Development Corporation, Japan Atomic Energy Research Institute, etc.). (Mori, K.)

  20. Exposure Scenarios and Unit Dose Factors for the Hanford Immobilized Low Activity Tank Waste Performance Assessment

    Energy Technology Data Exchange (ETDEWEB)

    RITTMANN, P.D.

    1999-12-29

    Exposure scenarios are defined to identify potential pathways and combinations of pathways that could lead to radiation exposure from immobilized tank waste. Appropriate data and models are selected to permit calculation of dose factors for each exposure

  1. Effect of Exposure Dose on Ichthyophonus Prevalence and Infection Intensity in Experimentally Infected Rainbow Trout, Oncorhynchus mykiss.

    Science.gov (United States)

    Kocan, Richard; LaPatra, Scott

    2016-02-01

    This study describes the effect of increasing exposure dose on Ichthyophonus prevalence and infection intensity in experimentally infected rainbow trout, Oncorhynchus mykiss. Specific-pathogen free trout were exposed per os to increasing numbers of Ichthyophonus schizonts obtained from naturally infected donor fish, then sampled after 30 and 60 days post-exposure. Both in vitro explant culture and histology revealed that as the number of schizonts per dose increased there was a proportionate increase in the number of infected fish, as well as an increase in the number of infected organs; parasite density in individual infected organs also increased with dose. Explant culture revealed that all fish exposed to the highest dose (≥2,080 schizonts) became infected, while only 67% of those exposed to the intermediate dose (1,040-1,153 schizonts) were Ichthyophonus-positive after 60 days; Ichthyophonus was not detected in fish exposed to the 2 lowest doses (≤280 schizonts). Histologic examination of individual infected organs also revealed increasing infection prevalence and parasite density in response to exposure to increasing numbers of Ichthyophonus schizonts.

  2. Repeated low-dose exposures to sarin, soman, or VX affect acoustic startle in guinea pigs.

    Science.gov (United States)

    Smith, C D; Lee, R B; Moran, A V; Sipos, M L

    2016-01-01

    Chemical warfare nerve agents (CWNAs) are known to cause behavioral abnormalities in cases of human exposures and in animal models. The behavioral consequences of single exposures to CWNAs that cause observable toxic signs are particularly well characterized in animals; however, less is known regarding repeated smaller exposures that may or may not cause observable toxic signs. In the current study, guinea pigs were exposed to fractions (0.1, 0.2, or 0.4) of a medial lethal dose (LD50) of sarin, soman, or VX for two weeks. On each exposure day, and for a post-exposure period, acoustic startle response (ASR) was measured in each animal. Although relatively few studies use guinea pigs to measure behavior, this species is ideal for CWNA-related experiments because their levels of carboxylesterases closely mimic those of humans, unlike rats or mice. Results showed that the 0.4 LD50 doses of soman and VX transiently increased peak startle amplitude by the second week of injections, with amplitude returning to baseline by the second week post-exposure. Sarin also increased peak startle amplitude independent of week. Latencies to peak startle and PPI were affected by agent exposure but not consistently among the three agents. Most of the changes in startle responses returned to baseline following the cessation of exposures. These data suggest that doses of CWNAs not known to produce observable toxic signs in guinea pigs can affect behavior in the ASR paradigm. Further, these deficits are transient and usually return to baseline shortly after the end of a two-week exposure period. Published by Elsevier Inc.

  3. [Exposure to toxic dose of adrenaline on the functional state of the liver].

    Science.gov (United States)

    Kopylova, S V; Vlasova, K M; Anashkina, A A

    2017-01-01

    The blood biochemical parameters characterizing the functional state of the liver, and the morphological profile of the body after a single exposure to a toxic dose of adrenaline were studied. Studies were conducted on 60 adult rats (female) weighing 0.15-0.2 kg, were divided into groups: intact animals; experience - animals, injected with epinephrine hydrochloride intraperitoneally in a dose of 0.5 mg/kg. All kinds of Biological material (blood, liver) were collected out through one and ten days after the start of the experiment. The degree of influence of high doses of epinephrine were evaluated in terms of lipid peroxidation (LPO) and protein (PSP) in liver homogenates, the concentration of average weight molecules (MSM), the activity of ALT, AST, alkaline phosphatase, LDH, total protein concentration, glucose and lactate in the blood plasma, as well as the determination of the prothrombin time (PTT) with the counting on the basis thereof of international normalized ration (INR). Histology of the liver was studied by light microscopy. It was found that throughout the experiment, there was an increased in the concentration of lipid peroxidation products and protein in liver homogenates, there was an increase in the concentration of MSM 1.7. Twenty-four hours after the administration of a toxic dose of adrenaline observed hyperenzymemia that manifested an increase in the activity of ALT and AST, was an increase in LDH. After 10-day five after the start of the experiment established the presence hyperenzymemia activity decreased ALT and AST, LDH activity remained elevated, total protein level was higher than in the group of animal in which investigations were conducted one day after the start of the experiment, PTV also continued to decline. In histological sections of the development of a pathological condition characterized by circulatory disturbance - plasmatization, both in central and in small vessels. From the hepatocytes both in the center and the periphery

  4. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  5. What do unsuccessful radiographs contribute to the total radiation dose to a patient

    International Nuclear Information System (INIS)

    Roth, J.; Nemec, H.W.

    1985-01-01

    Prevention of, or reduction of, unnecessary exposure to radiation is one of the prime goals of radiological protection in diagnostic radiology. The paper explains the advantages of a new approach, namely to achieve optimum focussing and adjustment of radiation sources for difficult imaging tasks by way of the fluoroscopic rather than the collimator method. The patient's exposure during this preliminary examination on the average will amount to 25 p.c. of the doses applied by the subsequent radiograph; on the other hand, this approach will reduce the number of unsuccessful pictures. (orig.) [de

  6. Expression of cytoskeletal and matrix genes following exposure to ionizing radiation: Dose-rate effects and protein synthesis requirements

    International Nuclear Information System (INIS)

    Woloschak, G.E.; Felcher, P.; Chang-Liu, Chin-Mei

    1992-01-01

    Experiments were designed to examine the effects of radiation dose-rate and of the protein synthesis inhibitor cycloheximide on expression of cytoskeletal elements (γ- and β-actin and α-tubulin) and matrix elements (fibronectin) in Syrian hamster embryo cells. Past work from our laboratory had already demonstrated optimum time points and doses for examination of radiation effects on accumulation of specific transcripts. Our results here demonstrated little effect of dose-rate for JANUS fission spectrum neutrons when comparing expression of either α-tubulin or fibronectin genes. Past work had already documented similar results for expression of actin transcripts. Effects of cycloheximide, however, revealed several interesting and novel findings: (1) Cycloheximide repressed accumulation of α-tubulin following exposure to high dose-rate neutrons or γ rays; this did not occur following similar low dose-rate exposure (2) Cycloheximide did not affect accumulation of mRNA for actin genes. Cycloheximide abrogated the moderate induction of fibronectin-mRNA which occurred following exposure to γ rays and high dose-rate neutrons. These results suggest a role for labile proteins in the maintenance of α-tubulin and fibronectin mRNA accumulation following exposure to ionizing radiation. In addition, they suggest that the cellular/molecular response to low dose-rate neutrons may be different from the response to high dose-rate neutrons

  7. C-reactive protein and serum amyloid A as early-phase and prognostic indicators of acute radiation exposure in nonhuman primate total-body irradiation model

    Energy Technology Data Exchange (ETDEWEB)

    Ossetrova, N.I., E-mail: ossetrova@afrri.usuhs.mil [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bldg. 42, Bethesda, MD 20889-5603 (United States); Sandgren, D.J.; Blakely, W.F. [Armed Forces Radiobiology Research Institute, 8901 Wisconsin Avenue, Bldg. 42, Bethesda, MD 20889-5603 (United States)

    2011-09-15

    Terrorist radiological attacks or nuclear accidents could expose large numbers of people to ionizing radiation. In mass-casualty radiological incidents early medical-management requires triage tools for first-responders to quantitatively identify individuals exposed to life-threatening radiation doses and for early initiation (i.e., within one day after radiation exposure) of cytokine therapy for treatment of bone marrow acute radiation syndrome. Herein, we present results from 30 rhesus macaques total-body irradiated (TBI) to a broad dose range of 1-8.5 Gy with {sup 60}Co {gamma}-rays (0.55 Gy min{sup -1}) and demonstrate dose- and time-dependent changes in blood of C-reactive protein (CRP), serum amyloid A (SAA), and interleukin 6 (IL-6) measured by enzyme linked immunosorbent assay (ELISA). CRP and SAA dose-response results are consistent with {approx}1 Gy and {approx}0.2 Gy thresholds for photon-exposure at 24 h after TBI, respectively. Highly significant elevations of CRP and SAA (p = 0.00017 and p = 0.0024, respectively) were found in animal plasma at 6 h after all TBI doses suggesting their potential use as early-phase biodosimeters. Results also show that the dynamics and content of CRP and SAA levels reflect the course and severity of the acute radiation sickness (ARS) and may function as prognostic indicators of ARS outcome. These results demonstrate proof-of-concept that these radiation-responsive proteins show promise as a complementary approach to conventional biodosimetry for early assessment of radiation exposures and may also contribute as diagnostic indices in the medical management of radiation accidents.

  8. Worst-Case Bias During Total Dose Irradiation of SOI Transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Colladant, T.; Paillet, P.; Leray, J.-L; Musseau, O.; Schwank, James R.; Shaneyfelt, Marty R.; Pelloie, J.L.; Du Port de Poncharra, J.

    2000-01-01

    The worst case bias during total dose irradiation of partially depleted SOI transistors (from SNL and from CEA/LETI) is correlated to the device architecture. Experiments and simulations are used to analyze SOI back transistor threshold voltage shift and charge trapping in the buried oxide

  9. Comparative response of dogs and monkeys to sublethal acute and continuous low dose-rate gamma-ray exposure

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.; Johnson, O.S.; LaBauve, P.M.; London, J.E.; Prine, J.R.; Vigil, E.A.

    1977-02-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (injury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with 35 R/day until death to determine the amount of radiation-induced injury remaining in conditioned animals as a reduction in mean survival time. Dogs (50 percent) and monkeys (8 percent) died from injury incurred during the conditioning exposures. Thus, the comparative response of dogs and monkeys to dose protraction by acute dose fractionation was similar to what might be expected from a single acute dose. Mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approximately 1400 h). Thus, hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35 R/day gamma-ray challenge exposure were greater than for their control counterparts. Thus, the long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than four times the acute LD 50 - 30 in dogs and approximately two times that of monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 R/day

  10. Effects of chronic exposure of seeds and seeds and seedlings of Arabidopsis Thaliana by low doses of γ-radiation on plant growth and development

    International Nuclear Information System (INIS)

    Litvinov, S.V.

    2013-01-01

    Article presents the results of research on the effect of chronic γ-irradiation in small doses on A. Thaliana seedlings and seeds growth and development. Exposure rate for the seeds was 0,45 mGy/h (total absorbed dose 30 cSv) and 0,18 mGy/h for seedlings (total absorbed dose 3 cSv). Statistically significant differences in the germination capacity, in the time of primary leaf rosette formation, in the hypocotyl length were revealed between irradiated and control seedlings. Plants from irradiated seeds differed by the higher growth rate of stem, they flowered and fruited earlier, but they also characterized on average shorter vegetative cycle in comparison with control plants. In our experiments it is shown significant impact of chronic low doses of γ-irradiation of seeds and seedlings on the ontogeny in A. Thaliana and on the parameters that reflect the growth and development of the irradiated plants

  11. The Increase in Animal Mortality Risk following Exposure to Sparsely Ionizing Radiation Is Not Linear Quadratic with Dose.

    Directory of Open Access Journals (Sweden)

    Benjamin M Haley

    Full Text Available The US government regulates allowable radiation exposures relying, in large part, on the seventh report from the committee to estimate the Biological Effect of Ionizing Radiation (BEIR VII, which estimated that most contemporary exposures- protracted or low-dose, carry 1.5 fold less risk of carcinogenesis and mortality per Gy than acute exposures of atomic bomb survivors. This correction is known as the dose and dose rate effectiveness factor for the life span study of atomic bomb survivors (DDREFLSS. It was calculated by applying a linear-quadratic dose response model to data from Japanese atomic bomb survivors and a limited number of animal studies.We argue that the linear-quadratic model does not provide appropriate support to estimate the risk of contemporary exposures. In this work, we re-estimated DDREFLSS using 15 animal studies that were not included in BEIR VII's original analysis. Acute exposure data led to a DDREFLSS estimate from 0.9 to 3.0. By contrast, data that included both acute and protracted exposures led to a DDREFLSS estimate from 4.8 to infinity. These two estimates are significantly different, violating the assumptions of the linear-quadratic model, which predicts that DDREFLSS values calculated in either way should be the same.Therefore, we propose that future estimates of the risk of protracted exposures should be based on direct comparisons of data from acute and protracted exposures, rather than from extrapolations from a linear-quadratic model. The risk of low dose exposures may be extrapolated from these protracted estimates, though we encourage ongoing debate as to whether this is the most valid approach. We also encourage efforts to enlarge the datasets used to estimate the risk of protracted exposures by including both human and animal data, carcinogenesis outcomes, a wider range of exposures, and by making more radiobiology data publicly accessible. We believe that these steps will contribute to better estimates

  12. Dose formation and hematologic effects with prolonged internal exposure of rats by isotope 131I

    International Nuclear Information System (INIS)

    Sova, O.A.; Drozd, Yi.P.

    2013-01-01

    Processes in single dose formation and long-term domestic revenue 131 I in rats was investigated. Original method of estimating absorbed doses in hemacyte for macro-dosemeters indicators was proposed. Dose factors for hemacyte and the dynamics of the blood-forming organs doses for prolonged two cases of prolonged exposure was calculated. Hematologic effects were studied for two variants of entry of the isotope. Peculiarities of doses formation and identified hematological effects are discussed

  13. Dose-rate effects for mammary tumor development in female Sprague-Dawley rats exposed to X and γ radiation

    International Nuclear Information System (INIS)

    Johnson, J.R.; Gragtmans, N.J.; Myers, D.K.; Jones, A.R.

    1989-01-01

    Mammary tumour development was followed in two experiments involving a total of 2229 female Sprague-Dawley rats exposed to various doses of X or γ rays at different dose rates. The data for another 462 rats exposed to tritiated water in one of these experiments were also analyzed. The incidence of adenocarcinomas and fibroadenomas at a given time after exposure increased linearly in proportion to total radiation dose for most groups. However, no significant increase in adenocarcinomas was observed with chronic γ exposures up to 1.1 Gy, and the increase in fibroadenomas observed with chronic gamma exposures at a dose rate of 0.0076 Gy h -1 up to an accumulated dose of 3.3 Gy was small compared to that observed after acute exposures. The incidence of all mammary tumors increased almost linearly with the log of dose rate in the range 0.0076 to 26.3 Gy h -1 for 3 Gy total dose of gamma rays. The effects of X rays appeared to be less influenced by dose rate than were the effects of γ rays. (author)

  14. Radiation dose evaluation based on exposure scenario during the operation of radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Yoon, Jeong Hyoun; Kim Chang Lak; Choi, Heui Joo; Park, Joo Wan

    1999-01-01

    Radiation dose to worker in disposal facility was calculated by using point kernel MICROSHIELD V5.02 computer code based on exposure scenarios. An conceptual design model for disposal vaults in disposal facility was used for object of shielding calculation model. Selected radionuclides and their activities among radioactive wastes from nuclear power plants were assumed as radiation sources for the exposure calculation. Annual radiation doses to crane workers and to people working on disposal vaults were calculated according to exposure time and distance from the sources with conservative operation scenarios. The scenarios used for this study were based on assumption for representing disposal activities in a future Korean near surface disposal facility. Calculated exposure rates to worker during normal disposal work were very low comparing with annual allowable limit for radiation worker

  15. Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures

    International Nuclear Information System (INIS)

    Endo, Akira; Petoussi-Henss, Nina; Zankl, Maria; Schlattl, Helmut; Bolch, Wesley E.; Eckerman, Keith F.; Hertel, Nolan E.; Hunt, John G.; Pelliccioni, Maurizio; Menzel, Hans-Georg

    2014-01-01

    This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors. This paper briefly reviews the reference computational phantoms and dose conversion coefficients for external exposures that were published jointly by ICRP and ICRU. Both these publications appeared as a consequence of the ICRP 2007 Recommendations; to implement these recommendations, the ICRP has developed reference computational phantoms representing the adult male and female. These phantoms are used to calculate reference dose conversion coefficients for external and internal sources. Using the reference phantoms and methodology consistent with the 2007 Recommendations, dose conversion coefficients for both effective doses and organ-absorbed doses for various types of idealised external exposures have been calculated. These data sets supersede the existing ICRP/ICRU data sets and expand the particle types and energy ranges. For neutrons, the new effective dose conversion coefficients become smaller compared with those in ICRP74, for energies below hundreds of keV. This is mainly

  16. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  17. Evaluation of automatic exposure control system chamber for the dose optimization when examining pelvic in digital radiography.

    Science.gov (United States)

    Kim, Sung-Chul; Lee, Hae-Kag; Lee, Yang-Sub; Cho, Jae-Hwan

    2015-01-01

    We found a way to optimize the image quality and reduce the exposure dose of patients through the proper activity combination of the automatic exposure control system chamber for the dose optimization when examining the pelvic anteroposterior side using the phantom of the human body standard model. We set 7 combinations of the chamber of automatic exposure control system. The effective dose was yielded by measuring five times for each according to the activity combination of the chamber for the dose measurement. Five radiologists with more than five years of experience evaluated the image through picture archiving and communication system using double blind test while classifying the 6 anatomical sites into 3-point level (improper, proper, perfect). When only one central chamber was activated, the effective dose was found to be the highest level, 0.287 mSv; and lowest when only the top left chamber was used, 0.165 mSv. After the subjective evaluation by five panel members on the pelvic image was completed, there was no statistically meaningful difference between the 7 chamber combinations, and all had good image quality. When testing the pelvic anteroposterior side with digital radiography, we were able to reduce the exposure dose of patients using the combination of the top right side of or the top two of the chamber.

  18. An epidemiological study on patient exposure from dental radiography

    International Nuclear Information System (INIS)

    Ehara, Masahiro

    1980-01-01

    The gonadal and bone marrow doses received by patients per exposure from dental X-ray examinations are small when compared to those of other medical X-ray procedures. Therefore, the contribution from dental X-ray exposure dose has not been discussed in terms of individual dose, but has always been considered in terms of population dose. However, depending on the peculiarity of the disease involved, some dental patients are considered to be subjected to relatively large doses of diagnostic X-rays. Therefore, from the standpoint of overall radiation protection, it was felt important to estimate the maximum individual dose incurred by diagnostic dental radiography. An epidemiological survey was undertaken at Osaka Dental University Hospital to estimate the maximum radiation exposure doses to various organs by projection. A total of 1301 patients were randomly selected from among persons who had initially visited the Radiology Department and subsequently received many X-ray exposures. The individual exposure dose to each organ was determined by projection based on the type and number of examinations. Results showed that the conditions incurring the maximum exposure dose in individual patients for diagnostic purposes in the dental region was those with ameloblastoma. (author)

  19. Quantification of acute vocal fold epithelial surface damage with increasing time and magnitude doses of vibration exposure.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kojima

    Full Text Available Because the vocal folds undergo repeated trauma during continuous cycles of vibration, the epithelium is routinely susceptible to damage during phonation. Excessive and prolonged vibration exposure is considered a significant predisposing factor in the development of vocal fold pathology. The purpose of the present study was to quantify the extent of epithelial surface damage following increased time and magnitude doses of vibration exposure using an in vivo rabbit phonation model. Forty-five New Zealand white breeder rabbits were randomized to nine groups and received varying phonation time-doses (30, 60, or 120 minutes and magnitude-doses (control, modal intensity phonation, or raised intensity phonation of vibration exposure. Scanning electron microscopy and transmission electron microscopy was used to quantify the degree of epithelial surface damage. Results revealed a significant reduction in microprojection density, microprojection height, and depth of the epithelial surface with increasing time and phonation magnitudes doses, signifying increased epithelial surface damage risk with excessive and prolonged vibration exposure. Destruction to the epithelial cell surface may provide significant insight into the disruption of cell function following prolonged vibration exposure. One important goal achieved in the present study was the quantification of epithelial surface damage using objective imaging criteria. These data provide an important foundation for future studies of long-term tissue recovery from excessive and prolonged vibration exposure.

  20. High Antigen Dose Is Detrimental to Post-Exposure Vaccine Protection against Tuberculosis.

    Science.gov (United States)

    Billeskov, Rolf; Lindenstrøm, Thomas; Woodworth, Joshua; Vilaplana, Cristina; Cardona, Pere-Joan; Cassidy, Joseph P; Mortensen, Rasmus; Agger, Else Marie; Andersen, Peter

    2017-01-01

    Mycobacterium tuberculosis (Mtb), the etiologic agent of tuberculosis (TB), causes 1.8M deaths annually. The current vaccine, BCG, has failed to eradicate TB leaving 25% of the world's population with latent Mtb infection (LTBI), and 5-10% of these people will reactivate and develop active TB. An efficient therapeutic vaccine targeting LTBI could have an enormous impact on global TB incidence, and could be an important aid in fighting multidrug resistance, which is increasing globally. Here we show in a mouse model using the H56 (Ag85B-ESAT-6-Rv2660) TB vaccine candidate that post-exposure, but not preventive, vaccine protection requires low vaccine antigen doses for optimal protection. Loss of protection from high dose post-exposure vaccination was not associated with a loss of overall vaccine response magnitude, but rather with greater differentiation and lower functional avidity of vaccine-specific CD4 T cells. High vaccine antigen dose also led to a decreased ability of vaccine-specific CD4 T cells to home into the Mtb-infected lung parenchyma, a recently discovered important feature of T cell protection in mice. These results underscore the importance of T cell quality rather than magnitude in TB-vaccine protection, and the significant role that antigen dosing plays in vaccine-mediated protection.

  1. A method, using ICRP 26 weighting factors, to determine effective dose equivalent due to nonuniform external exposures

    International Nuclear Information System (INIS)

    Dyer, S.G.

    1993-01-01

    Westinghouse Savannah River Company (WSRC) has recently implemented a methodology and supporting procedures to calculate effective dose equivalent for external exposures. The calculations are based on ICRP 26 methodology and are used to evaluate exposures when multibadging is used. The methodology is based upon the concept of open-quotes whole bodyclose quotes compartmentalization (i.e., the whole body is separated into seven specific regions of radiological concern and weighted accordingly). The highest dose measured in each compartment is used to determine the weighted dose to that compartment. Benefits of determining effective dose equivalent are compliance with DOE Orders, more accurate dose assessments, and the opportunity for improved worker protection through new ALARA opportunities

  2. Lymphocytic subsets and low-dose exposure

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Eybl, E.

    1993-03-01

    The present investigations proved the differential radiosensitivity of lymphocytic subpopulations: From in vivo and in vitro irradiations it may be followed that the most sensitive subset are CD8 positive suppressor T cells. CD4/CD8 ratios are increased both in peripheral blood and after mitogen stimulation of lymphocytes of exposed persons. The decrease in B cells is pronounced only at higher radiation doses. Though the rate of DNA synthesis after mitogen stimulation was reduced in some exposed persons, that was no general phenomenon. Especially after tritium exposure, the observed lymphopenia correlated with an increased stimulation by PHA and an increased rate of DNA synthesis in some probands. Thus the present investigations indicate that - despite an inhibition of some immune parameters by radioexposure - the body is able to maintain its immunological homoeostasis. (authors)

  3. Occupational exposure to ionising radiation 1990-1996. Analysis of doses reported to the Health and Safety Executive's Central Index of Dose Information

    International Nuclear Information System (INIS)

    1998-01-01

    The Central Index of Dose Information (CIDI) is the Health and Safety Executive's (HSE's) national database of occupational exposure to ionising radiation. It is operated under contract by the National Radiological Protection Board (NRPB). CIDI receives annually, from Approved Dosimetry Services (ADS) summaries of radiation doses recorded for employees designated as classified persons in the United Kingdom. This is the second analysis of dose summary information to be published. (author)

  4. Radiation doses to neonates requiring intensive care

    International Nuclear Information System (INIS)

    Robinson, A.; Dellagrammaticas, H.D.

    1983-01-01

    Radiological investigations have become accepted as an important part of the range of facilities required to support severely ill newborn babies. Since the infants are so small, many of the examinations are virtually ''whole-body'' irradiations and it was thought that the total doses received might be appreciable. A group of such babies admitted to the Neonatal Intensive Care Unit in Sheffield over a six-month period have been studied. X-ray exposure factors used for each examination have been noted and total skin, gonad and bone marrow doses calculated, supplemented by measurements on phantoms. It is concluded that in most cases doses received are of the same order as those received over the same period from natural background radiation and probably less than those received from prenatal obstetric radiography, so that the additional risks from the diagnostic exposure are small. The highest doses are received in CT scans and barium examinations and it is recommended that the need for these should be carefully considered. (author)

  5. Radiation risk from terrestrial exposure for population in cities of Serbia

    International Nuclear Information System (INIS)

    Jankovic-Mandic, Lj.; Dragovic, S.; Jankovic-Mandic, Lj.)

    2007-01-01

    In this work total gamma dose rate, annual effective dose and external hazard index are calculated based on specific activities of 226 Ra, 232 Th and 40 K determined by gamma-ray spectrometry. The average value of total gamma dose rate (61.8 n Gy/h) and annual effective dose (7.58·10 -5 Sv) from terrestrial exposure in 22 cities in Serbia are close to average world values. The average value of external hazard index of 0.35 showed that there is no significant radiation risk for population in cities of Serbia from terrestrial exposure. (author) [sr

  6. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose- effect curve)

    International Nuclear Information System (INIS)

    Al Achkar, W.

    2002-01-01

    In order to draw a dose-effect curve, blood from eight healthy people were studied. Samples were irradiated in tubes with 0.15-2.5 gray of gamma ray.Irradiated and control samples were incubated for cell cultures. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics+ rings and total numbers of breaks were drawn. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  7. Plants ecotoxicology. A case of low doses and multi pollutant exposure

    Energy Technology Data Exchange (ETDEWEB)

    Geras' Kin, S.; Kim, J.; Evseeva, T.; Oudalova, A.; Dikarev, V. [Russian Institute of Agricultural Radiology and Agroecology, Obninsk (Russian Federation)

    2004-07-01

    In this report, results of long-term laboratory, 'green-house' and field experiments carried out on different species of wild and agricultural plants (spring barley, Scots pine, spider wort, bulb onion and others) to study toxic and genotoxic effects of low doses and concentrations of such common pollutants as acute and chronic {gamma}-radiation, heavy natural radionuclides, compounds of heavy and alkaline earth metals, pesticides are presented for the first time. Special attention is paid to eco-toxic effects of chronic low dose exposures, the dose-rate effect, synergistic and antagonistic effects of different factors' combined exposures and biological effects of incorporated radionuclides. The results of long-term field experiments in the 30-km Chernobyl NPP zone, in the vicinity of the facility for the processing and storage of radioactive wastes (Leningrad region), in the vicinity of the radium production industry storage cell (Komi Republic), at the site of an underground nuclear explosion (Perm region) are discussed. These findings suggest that the further evolution of investigations in this field would issue in the development of a theoretical bases and practical procedures for environmental protection against radioactivity, taking into account the new experimentally confirmed facts about the presence of such essentially important singularities of the biological effect of low ionizing radiation doses as the nonlinearity of a dose-effect relationship, radiation-induced genomic instability, phenomenon of radio-adaptation, increased probability of synergetic and antagonistic effects of the combined action of different nature factors. A development of a new concept of radiation protection for a human and biota should be based on the clear understanding of these effects and their contribution to the response of biological objects. (author)

  8. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  9. Dose- and Ion-Dependent Effects in the Oxidative Stress Response to Space-Like Radiation Exposure in the Skeletal System

    Science.gov (United States)

    Alwood, Joshua S.; Tran, Luan H.; Schreurs, Ann-Sofie; Shirazi-Fard, Yasaman; Kumar, Akhilesh; Hilton, Diane; Tahimic, Candice G. T.; Globus, Ruth

    2017-01-01

    Exposure to space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized exposure to ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-week old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 mega electron volts per nucleon) or high-LET (sup 56) Fe ions (600 mega electron volts per nucleon) using either low (5 or 10 centigrays) or high (50 or 200 centigrays) doses at NASAs Space Radiation Lab at Brookhaven National Lab (NSRL/BNL). Tissues were harvested 5 weeks or 1 year after irradiation and bones were analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed for select groups by RT-PCR (Reverse Transcription-Polymerase Chain Reaction) during the proliferative phase or the mineralizing phase, and differentiation was analyzed by imaging mineralized nodules (percentage surface area). Representative genes were selected for expression analyses, including cell proliferation (PCNA, Cdk2, p21, p53), differentiation (Runx2, Alpl, Bglap), oxidative metabolism (Catalase, GPX, MnSOD, CuZnSOD, iNos, Foxo1), DNA-damage repair (Gadd45), or apoptosis (Caspase 3). As expected, a high dose (200 centigrays), but not low doses, of either (sup 56) Fe or protons caused a loss of cancellous bone volume per total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; (sup 56) Fe (200 centigrays) inhibited median nodule area by more than 90 percent at 5 weeks and 1 year post-irradiation, compared to controls. At 5 weeks post

  10. Estimation of population doses from diagnostic medical examinations in Japan, 1974. III. Per caput mean marrow dose and leukemia significant dose

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-03-01

    The mean per capita marrow dose and leukemia-significant dose from radiographic and fluoroscopic examinations in Japan have been estimated based on a 1974 nation wide survey of randomly sampled hospitals and clinics. To determine the mean marrow dose to an individual from a certain exposure of a given type of examination, the active marrow in the whole body was divided into 119 parts for an adult and 103 for a child. Dosimetric points on which the individual marrow doses were determined were set up in the center of each marrow part. The individual marrow doses at the dosimetric points in the beams of practical diagnostic x-rays were calculated on the basis of the exposure data on the patients selected in the nation wide survey, using depth dose curves experimentally determined for diagnostic x-rays. The mean individual marrow dose was averaged over the active marrow by summing, for each dosimetric point, the product of the fraction of active marrow exposed and the individual marrow dose at the dosimetric point. The leukemia significant dose was calculated by adopting a weighting factor that is, a leukemia significant factor. The factor was determined from the shape of the time-incidence curve for radiation-induced leukemia from the Hiroshima A-bomb and from the survival statistics for the average population. The resultant mean per capita marrow dose from radiographic and fluoroscopic examination was 37.0 and 70.0 mrad/person/year, respectively, with a total of 107.05 mrad/person/year. The leukemia significant dose was 32.1 mrad/person/year for radiographic examination and 61.2 mrad/person/year, with a total of 93.3. These values were compared with those of 1960 and 1969.

  11. Effect of continuous gamma-ray exposure on performance of learned tasks and effect of subsequent fractionated exposures on blood-forming tissue

    Science.gov (United States)

    Spalding, J. F.; Holland, L. M.; Prine, J. R.; Farrer, D. N.; Braun, R. G.

    1972-01-01

    Sixteen monkeys trained to perform continuous and discrete-avoidance and fixed-ratio tasks with visual and auditory cues were performance-tested before, during, and after 10-day gamma-ray exposures totaling 0, 500, 750, and 1000 rads. Approximately 14 months after the performance-test exposures, surviving animals were exposed to 100-rad gamma-ray fractions at 56-day intervals to observe injury and recovery patterns of blood-forming tissues. The fixed-ratio, food-reward task performance showed a transient decline in all dose groups within 24 hours of the start of gamma-ray exposure, followed by recovery to normal food-consumption levels within 48 to 72 hours. Avoidance tasks were performed successfully by all groups during the 10-day exposure, but reaction times of the two higher dose-rate groups in which animals received 3 and 4 rads per hour or total doses of 750 and 1000 rads, respectively, were somewhat slower.

  12. Evaluation and distribution of doses received by Cuban population due to environmental sources of radioactivity

    International Nuclear Information System (INIS)

    Zerquera, Juan T.; Prendes Alonso, Miguel; Fernandez Gomez, Isis M.; Lopez Bejerano, Gladys

    2008-01-01

    Full text: In the frame of a national research project supported by the Nuclear Energy Agency of the Ministry of Science, Technology and Environment of the Republic of Cuba doses received by Cuban population due to the exposure to existing in the environment sources of radiation were assessed. Direct measurements of sources representing 90% of average total doses to world population according to UNSCEAR data were made and estimations of doses were obtained for the different components of the total dose: doses due to the exposure to cosmic radiation, external terrestrial radiation, potassium contained in human body and inhalation and ingestion of radionuclides present in the environment. Using the obtained results it was made an estimation of total doses to Cuban population due to environmental radiation sources and the contributions of different dose components were assessed. This was carried out through a Monte Carlo simulation of the total doses using the parameter of dose distributions obtained for the different contributors (components) to total dose. On the basis of the estimations the average total effective dose to Cuban population due to the exposure to environmental sources was estimated as 1.1 ± 0.3 mSv per year. This low dose value is in the range of doses estimated by UNSCEAR for world population due to natural background and can be explained by the specific of Cuban environment: a majority of the population living at the sea level or at low altitudes, relative low content of primordial radionuclides in soils and high ventilation rates in dwellings. All the instructions specified in the Call for Abstracts should be taken into account. e/ 41 and 457. (author)

  13. The 1997 determination of the Australian standards of exposure and absorbed dose at {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Huntley, R.B.; Boas, J.F. [Australian Radiation Laboratory, Yallambie, VIC (Australia); Van der Gaast, H. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1998-05-01

    The arrangements for the maintenance of the Australian standards for {sup 60}Co are described in detail. The primary standards are a graphite cavity chamber for exposure/air kerma and a graphite calorimeter for absorbed dose. These secondary standards are described and their responses in corresponding {sup 90}Sr reference sources are reported. Accurate ratios between the Australian Radiation Laboratory (ARL) and Australian Nuclear Science and Technology (ANSTO) {sup 90}Sr reference sources are derived for use in future calibrations. The value of 28.8 years for the half-life of {sup 90}Sr is confirmed. The usefulness of {sup 90}Sr reference source measurements in quality assurance is discussed. The charge sensitivity and linearity of the ANSTO electrometers are reported by two different methods and are compared with previous results. Calibration factors for all the secondary standard ionization chambers are given, in terms of exposure, air kerma and absorbed dose to water. Calibration factors are also given for most of the chambers in terms of absorbed dose to graphite. The methods of deriving the calibration factors are explained in detail, including all the corrections applied to both the primary and secondary standard measurements. Three alternative methods of deriving the absorbed dose to water calibration factors are compared. The reported calibration factors are compared with previous results. Changes in the Australian units of exposure, air kerma and absorbed dose to graphite and water are derived from changes in the corresponding calibration factors. The Australian units of exposure and air kerma have not changed significantly since 1990. The Australian unit of absorbed dose to graphite is now 1.1 % smaller than in 1993 and 1.3 % smaller than in 1990. The Australian unit of absorbed dose to water is now 1.4 % smaller than in 1993, but is only 0.9 % smaller than in 1990. Comparisons of the Australian standards of exposure/air kerma and absorbed dose with

  14. Exploratory Study of Total and Free Prednisolone Plasma Exposure and Cushingoid Appearance, Quality of Life and Biochemical Toxicity in Adult Male Kidney Transplant Recipients

    DEFF Research Database (Denmark)

    Bergmann, Troels K; Isbel, Nicole M; Ostini, Remo

    2015-01-01

    relationships between prednisolone exposure and adverse effects. METHODS: Male kidney transplant recipients were recruited for serial blood sampling and assessment of glucocorticoid-related adverse effects including dyslipidaemia, abnormal body fat distribution, Cushingoid appearance and impaired quality...... of life. Total and free prednisolone plasma concentrations were determined using ultra-high-performance liquid chromatography with tandem mass spectrometric detection. Prednisolone exposure was estimated using a limited sampling strategy. RESULTS: Fifty-six patients were recruited. Patients had a mean age...... of 54 years and median time post-transplantation of 75 months. Median prednisolone dose was 5 mg. Mean area under the plasma concentration-time curve was 2390 nmol h/L (±580) (SD) and 175 nmol h/L (±78) for total and free prednisolone, respectively. Waist to upper arm circumference ratio was positively...

  15. Evaluation the total exposure of soil sample in Adaya site and the obtain risk assessments for the worker by Res Rad code program

    International Nuclear Information System (INIS)

    Mahadi, A. M.; Khadim, A. A. N.; Ibrahim, Z. H.; Ali, S. A.

    2012-12-01

    The present study aims to evaluation the total exposure to the worker in Adaya site risk assessment by using Res Rad code program. The study including 5 areas soil sample calculate in the site and analysis it by High Pure Germaniums (Hg) system made (CANBERRA) company. The soil sample simulation by (Res Rad) code program by inter the radioactive isotope concentration and the specification of the contamination zone area, depth and the cover depth of it. The total exposure of same sample was about 9 mSv/year and the (Heast 2001 Morbidity, FGR13 Morbidity) about 2.045 state every 100 worker in the year. There are simple different between Heast 2001 Morbidity and FGR13 Morbidity according to the Dose Conversion Factor (DCF) use it. The (FGR13 Morbidity) about 2.041 state every 100 worker in the year. (Author)

  16. Effects of chronic low-dose radiation exposure and non-radiation factors on eye pathology in the Techa River Cohort

    International Nuclear Information System (INIS)

    Mikryukova, L.D.; Akleyev, A.V.

    2008-01-01

    Full text: As a result of the Mayak PA activities, radioactive wastes were discharged into the Techa River over the period 1949-1956. Data on eye pathology among Techa riverside residents chronically exposed to radiation (external and internal) have been collected and analyzed. The cohort which includes persons of the two genders born before 1950 gives one of the rare opportunities to assess the risk of late effects on human health associated with small-dose radiation exposure. Currently, the cohort numbers 29,749 individuals. In terms of ethnicity, 80 % of the cohort members are Slavs, and 20 % are Tartars and Bashkirs. The first study and analyses of eye pathology were conducted for this cohort during the period from 2001 through 2004. It was established that the cumulative rate of eye disease incidence increased with age and exposure dose. The relative risk value for development of ophthalmopathy among members of the study group was estimated taking into account the potential effects of gender, ethnicity and attained age. The relative risk value was 2.42 per 1 Gy of absorbed dose to soft tissues (95 % CI: 1.94; 3.03). With increase in attained age by 10 years an 8 % increase in the incidence of eye pathology was registered (p<0.001). The rate of eye disease incidence estimated for women was significantly higher than that for men (p<0.05 %). No significant differences were noted in the coefficient of eye disease incidence calculated for different ethnic groups. The structure of ophthalmopathy registered in residents of the Techa riverside villages chronically exposed in the dose range from 0 to 1,180 mGy is characterized by prevalence of cataracts, retinal and chorioid disorders. The rates of eye disease incidence were found to be dependent on external exposure dose; the highest doses were observed in the dose groups with doses 25 mGy. A statistically significant increase in the incidence of retinal angiosklerosis and a manifest tendency to develop cataracts was

  17. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  18. Patient radiation dose during mammography procedures

    International Nuclear Information System (INIS)

    Mohamed, Swsan Awd Elkriem

    2015-11-01

    The objectives of this study were to estimate the patient dose in term of mean glandular dose and assist in optimization of radiation protection in mammographic procedures in Sudan. A total number of 107 patients were included. Four mammographic units were participated. Only one center was using automatic exposure control (AEC). The mean doses in (mGy) for the CC projection were 3.13, 1.24, 2.45 and 0.98 and for the MLO projection was 2.13, 1.26, 1.99 and 1.02 for centers A, B, C, and D, respectively. The total mean dose per breast from both projections was 5.26, 2.50, 4.44 and 1.99 mGy for centers A, B, C and D, respectively. The minimum mean glandular dose was found between the digital system which was operated under AEC and one of the manual selected exposure factors systems, this highlight possible optimization of radiation protection in the other manual selected systems. The kilo volt and the tube current time products should be selected correctly according to the breast thickness in both centers A and C. (author)

  19. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  20. Development of a external exposure computational model for studying of input dose in skin for radiographs of thorax and vertebral column

    International Nuclear Information System (INIS)

    Muniz, Bianca C.; Menezes, Claudio J.M.; Vieira, Jose W.

    2014-01-01

    The dosimetric measurements do not always happen directly in the human body. Therefore, these assessments can be performed using anthropomorphic models (phantoms) evidencing models computational exposure (MCE) using techniques of Monte Carlo Method for virtual simulations. These processing techniques coupled with more powerful and affordable computers make the Monte Carlo method one of the tools most used worldwide in radiation transport area. In this work, the Monte Carlo EGS4 program was used to develop a computer model of external exposure to study the entrance skin dose for chest and column X-radiography and, aiming to optimize these practices by reducing doses to patients, professionals involved and the general public. The results obtained experimentally with the electrometer Radcal, model 9015, associated with the ionization chamber for radiology model 10X5-6, showed that the proposed computational model can be used in quality assurance programs in radiodiagnostic, evaluating the entrance skin dose when varying parameters of the radiation beam such as kilo voltage peak (kVp), current-time product (mAs), total filtration and distance surface source (DFS), optimizing the practices in radiodiagnostic and meeting the current regulation

  1. Time- and dose rate-related effects of internal 177Lu exposure on gene expression in mouse kidney tissue

    International Nuclear Information System (INIS)

    Schüler, Emil; Rudqvist, Nils; Parris, Toshima Z.; Langen, Britta; Spetz, Johan; Helou, Khalil; Forssell-Aronsson, Eva

    2014-01-01

    Introduction: The kidneys are the dose-limiting organs in some radionuclide therapy regimens. However, the biological impact of internal exposure from radionuclides is still not fully understood. The aim of this study was to examine the effects of dose rate and time after i.v. injection of 177 LuCl 3 on changes in transcriptional patterns in mouse kidney tissue. Methods: To investigate the effect of dose rate, female Balb/c nude mice were i.v. injected with 11, 5.6, 1.6, 0.8, 0.30, and 0 MBq of 177 LuCl 3 , and killed at 3, 6, 24, 48, 168, and 24 hours after injection, respectively. Furthermore, the effect of time after onset of exposure was analysed using mice injected with 0.26, 2.4, and 8.2 MBq of 177 LuCl 3 , and killed at 45, 90, and 140 days after injection. Global transcription patterns of irradiated kidney cortex and medulla were assessed and enriched biological processes were determined from the regulated gene sets using Gene Ontology terms. Results: The average dose rates investigated were 1.6, 0.84, 0.23, 0.11 and 0.028 mGy/min, with an absorbed dose of 0.3 Gy. At 45, 90 and 140 days, the absorbed doses were estimated to 0.3, 3, and 10 Gy. In general, the number of differentially regulated transcripts increased with time after injection, and decreased with absorbed dose for both kidney cortex and medulla. Differentially regulated transcripts were predominantly involved in metabolic and stress response-related processes dependent on dose rate, as well as transcripts associated with metabolic and cellular integrity at later time points. Conclusion: The observed transcriptional response in kidney tissue was diverse due to difference in absorbed dose, dose rate and time after exposure. Nevertheless, several transcripts were significantly regulated in all groups despite differences in exposure parameters, which may indicate potential biomarkers for exposure of kidney tissue

  2. [Evaluation of an Experimental Production Wireless Dose Monitoring System for Radiation Exposure Management of Medical Staff].

    Science.gov (United States)

    Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung

    2015-08-01

    Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.

  3. Relationship to carcinogenesis of repetitive low-dose radiation exposure

    International Nuclear Information System (INIS)

    Ootsuyama, Akira

    2016-01-01

    We studied the carcinogenic effects caused by repetitive irradiation at a low dose, which has received attention in recent years, and examined the experimental methods used to evaluate radiation-induced carcinogenesis. For this experiment, we selected a mouse with as few autochthonous cancers as possible. Skin cancer was selected as the target for analysis, because it is a rare cancer in mice. Beta-rays were selected as the radiation source. The advantage of using beta-rays is weaker penetration power into tissues, thus protecting organs, such as the digestive and hematogenous organs. The benefit of our experimental method is that only skin cancer requires monitoring, and it is possible to perform long-term experiments. The back skin of mice was exposed repetitively to beta-rays three times a week until the occurrence of cancer or death, and the dose per exposure ranged from 0.5 to 11.8 Gy. With the high-dose range (2.5-11.8 Gy), the latency period and carcinogenic rate were almost the same in each experimental group. When the dose was reduced to 1-1.5 Gy, the latency period increased, but the carcinogenic rate remained. When the dose was further reduced to 0.5 Gy, skin cancer never happened, even though we continued irradiation until death of the last mouse in this group. The lifespan of 0.5 Gy group mice was the same as that of the controls. We showed that the 0.5 Gy dose did not cause cancer, even in mice exposed repetitively throughout their life span, and thus refer to 0.5 Gy as the threshold-like dose. (author)

  4. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  5. Investigation of exposure dose of residents and standards for the interim storage of wastes from the restricted area

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    Remediation in the restricted area around the Fukushima Daiichi Nuclear Power Plant is being planned. JNES conducted the investigation to support controlling the exposure pathway for exposure of residents. Prototype dose evaluation tool for the residents in the restricted area was developed. Residents would be externally and internally exposed. Monitoring data of concentration of radioactive material in the air, soil, water, agricultural products and fish, and exposure scenario were compiled to be used in the dose evaluation tool. Upon requests from the Local Nuclear Emergency Response Headquarters (LNERH), JNES has conducted investigations of the exposure dose for local residents, car mechanics, drivers, fire fighters, workers of incineration plant, seawage plant and final disposal of waste in their activities. Preliminary investigation of the safety of interim storage for wastes from decontamination was also conducted. (author)

  6. Exposure dose to gonad and its reduction in CT examinations

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Menju, Mina; Nakazawa, Masato

    2006-01-01

    Exposure doses to gonad (ovary and uterus) due to scattering at the ordinary CT examinations of head, breast, and abdomen (liver) were measured and their reductions by the protective apron usually used in clinic were evaluated by comparison of the given and International Commission of Radiological Protection (ICRP) data for risk assessment. Multi-slice helical/scanno-helical CT for the regions under ordinary diagnostic conditions was done by the apparatus Toshiba Aquilion 16 for the human body phantom (Alderson) with or without the apron (Hagoromo) equivalent to 0.25 mm thick lead. Doses inside and outside the beam flux were measured by the thermoluminescent dosimeter, of which data were corrected by Radcal Model 300 ionization chamber. The doses in the gonad due to scattering were found to be in the range from 0.01 (head CT) to 1 (liver CT) mGy and to be reduced in 20-30% by the apron. Found dose were far smaller than the ICRP threshold values for inducing teratosis and infertality. (T.I.)

  7. Occupational radiation exposure in the GDR in 1977

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1977, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,348 persons), measurements with a whole-body counter (198 persons) and analyses of biosamples (174 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 253. In 6 cases the monthly exposure exceeded 30 mGy and the 9 highest annual exposure values were in the range of 50 to 120 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual radiation exposure was below one-tenth the maximum permissible dose. (author)

  8. Calculation of age-dependent effective doses for external exposure using the MCNP code

    International Nuclear Information System (INIS)

    Hung, Tran Van

    2013-01-01

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  9. Calculation of age-dependent effective doses for external exposure using the MCNP code

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Tran Van [Research and Development Center for Radiation Technology, ThuDuc, HoChiMinh City (VT)

    2013-07-15

    Age-dependent effective dose for external exposure to photons uniformly distributed in air were calculated. Firstly, organ doses were calculated with a series of age-specific MIRD-5 type phantoms using the Monte Carlo code MCNP. The calculations were performed for mono-energetic photon sources with source energies from 10 keV to 5 MeV and for phantoms of newborn, 1, 5, 10, and 15 years-old and adult. Then, the effective doses to the different age-phantoms from the mono-energetic photon sources were estimated based on the obtained organ doses. From the calculated results, it is shown that the effective doses depend on the body size; the effective doses in younger phantoms are higher than those in the older phantoms, especially below 100 keV. (orig.)

  10. Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.

    Science.gov (United States)

    Wollschläger, Daniel; Hammer, Gaël Paul; Schafft, Thomas; Dreger, Steffen; Blettner, Maria; Zeeb, Hajo

    2018-05-01

    Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01-6.39 mSv). In addition to an inverse association with solar activity, exposure followed age- and sex-dependent patterns related to individual career development and life phases. JEM-derived annual cockpit crew doses agreed with SSR-provided doses for 2004 (correlation 0.90, 0.40 mSv root mean squared error), while the estimated average annual effective dose for cabin crew had a prediction error of 0.16 mSv, equaling 7.2% of average annual dose. Past average annual cabin crew dose can be modeled by exploiting systematic external influences as well as individual behavioral determinants of radiation exposure, thereby enabling future dose-response analyses of the full aircrew cohort including measurement error information.

  11. Dose rate and total dose dependence of the 1/f noise performance of a GaAs operational amplifier during irradiation

    International Nuclear Information System (INIS)

    Hiemstra, D.M.

    1995-01-01

    A pictorial of a sectioned view of the torus of the International Thermonuclear Experimental Reactor (ITER) is shown. Maintenance and inspection of the reactor are required to be performed remotely. This is due to the high gamma radiation environment in vessel during inspection and maintenance activities. The custom GaAs operational amplifier is to be used to readout sensors on the in-vessel manipulator and inspection equipment. The gamma dose rate during maintenance and inspection is anticipated to be 3 Mrad(GaAs)/hour. Here, dose rate and total dose dependence of the 1/f noise performance of a custom GaAs MESFET operational amplifier during irradiation are presented. Dose rate dependent 1/f noise degradation during irradiation is believed to be due to electron trapping in deep levels, enhanced by backgating and shallow traps excited during irradiation. The reduction of this affect with accumulated total dose is believed to be due a reduction of deep level site concentration associated with substitutional oxygen. Post irradiation 1/f noise degradation is also presented.The generation-recombination noise observed post irradiation can be attributed to the production of shallow traps due to ionizing radiation

  12. The dose-response relationship between in-ear occupational noise exposure and hearing loss.

    Science.gov (United States)

    Rabinowitz, Peter M; Galusha, Deron; Dixon-Ernst, Christine; Clougherty, Jane E; Neitzel, Richard L

    2013-10-01

    Current understanding of the dose-response relationship between occupational noise and hearing loss is based on cross-sectional studies prior to the widespread use of hearing protection, and with limited data regarding noise exposures below 85 dBA. We report on the hearing loss experience of a unique cohort of industrial workers, with daily monitoring of noise inside of hearing protection devices. At an industrial facility, workers exhibiting accelerated hearing loss were enrolled in a mandatory programme to monitor daily noise exposures inside of hearing protection. We compared these noise measurements (as time-weighted LAVG) to interval rates of high-frequency hearing loss over a 6-year period using a mixed-effects model, adjusting for potential confounders. Workers' high-frequency hearing levels at study inception averaged more than 40 dB Hearing threshold level (HTL). Most noise exposures were less than 85 dBA (mean LAVG 76 dBA, IQR 74-80 dBA). We found no statistical relationship between LAvg and high-frequency hearing loss (p=0.53). Using a metric for monthly maximum noise exposure did not improve model fit. At-ear noise exposures below 85 dBA did not show an association with risk of high-frequency hearing loss among workers with substantial past noise exposure and hearing loss at baseline. Therefore, effective noise control to below 85 dBA may lead to significant reduction in occupational hearing loss risk in such individuals. Further research is needed on the dose-response relationship of noise and hearing loss in individuals with normal hearing and little prior noise exposure.

  13. Metoprolol Dose Equivalence in Adult Men and Women Based on Gender Differences: Pharmacokinetic Modeling and Simulations

    Directory of Open Access Journals (Sweden)

    Andy R. Eugene

    2016-11-01

    Full Text Available Recent meta-analyses and publications over the past 15 years have provided evidence showing there are considerable gender differences in the pharmacokinetics of metoprolol. Throughout this time, there have not been any research articles proposing a gender stratified dose-adjustment resulting in an equivalent total drug exposure. Metoprolol pharmacokinetic data was obtained from a previous publication. Data was modeled using nonlinear mixed effect modeling using the MONOLIX software package to quantify metoprolol concentration–time data. Gender-stratified dosing simulations were conducted to identify equivalent total drug exposure based on a 100 mg dose in adults. Based on the pharmacokinetic modeling and simulations, a 50 mg dose in adult women provides an approximately similar metoprolol drug exposure to a 100 mg dose in adult men.

  14. Total external dose equivalent and effective dose derived to the Piedmont population in the period 30 Apr 1986 - 22 Sep 1987

    International Nuclear Information System (INIS)

    Cortissone, C.; Giacomelli, R.; Spezzano, P.; Porzio, L.

    1988-01-01

    Some dosimetric evaluations concerning the population of the Piemonte Region, obtained after the measurements made following the Chernobyl accident, are reported. The individual effective mean dose equivalent derived from the exposure and intake in the period April 30, 1986 - September 22, 1987, is about 0.50 mSv

  15. Means of evaluation of population dose from the natural background of radiation for control of the exposure of environment of nuclear power plants

    International Nuclear Information System (INIS)

    Pensko, J.

    1974-01-01

    Given in this paper are the method and the results of calculation of the average value of the equivalent of the dose of the natural background of radiation, affecting the gonads and the bone marrow of the inhabitants of one of the regions of Poland, chosen as an example. These values weighed on a number of more important environmental factors, amounts to 78.0 mrem/years for gonads and 72.1 mrem/year for bone marrow. The value of the total population dose for the investigated region, from these sources of radiation, does not exceed 1.2 x 10 4 man-rem/year. Calculations were performed mainly on the base of the results of measurements of the exposure dose rate by a scintillation monitor from aboard an airplane, using also the numerous measurements of the dose at the height of 1 m over the earth's surface, done by means of a high-pressure ionization chamber, and the results of gamma spectrometric analysis of samples of soil. In calculations, coefficients of transformation of the exposure dose into the dose absorbed by various tissues, and the time spent indoors, were taken into consideration. For this purpose, using a proper coefficient of building screen has been suggested. This method can be used for estimating the average population dose, from the external radiation originating from natural and artificial radioactive sources, present in the environment of nuclear power plants. (author)

  16. Estimation of Exposure Doses for Several Scenarios of the Landfill Disposal of NORM Wastes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jong Tae; Ko, Nak Yul; Baik, Min Hoon [KAERI, Daejeon (Korea, Republic of); Yoon, Ki Hoon [Korea Institude of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-05-15

    The Act on safety control of radioactive materials around living environment was promulgated to protect citizen's health and environment in 2013. According to this Act, the integrated plan for radiation protection and the necessary safety guides for treatment, reuse, and disposal of NORM wastes have to be made. And NORM wastes have to be disposed in landfill sites by reducing the concentration of radionuclide, and they should not be reutilized. In this study, we estimated exposure doses for several scenarios for NORM (Naturally Occurring Radioactive Materials) waste disposal into a reference landfill site to check the radiological safety. Also, we estimated the amount of NORM wastes for different activity levels of important radionuclides in wastes to be disposed into a landfill site based on the exposure dose limits to support the establishment of technical bases for safety guide. We estimated the amount of NORM wastes for different activity levels of wastes containing U series, Th series, and {sup 40}K based on the exposure dose limits. The results of this study can be used as technical bases to support the establishment of a guide for the safe management of NORM waste disposal.

  17. Determination of permissible exposure doses under the provisions of the regulations on installation and operation of marine reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The Ministry of Transportation defines on radioactive doses in the controlled area that exterior radioactive dose shall be 30 mili-rem for a week; concentrations of radioactive materials in the air or under the water shall be permissible concentrations otherwise specified for the employees multiplied by 0.75 in average for a week and that densities of radioactive materials on the surface of the things contaminated by such materials shall be 1/10 of permissible surface densities provided in a table attached. Permissible exposure dose outside the inspected surrounding area is 0.5 rem for a year. Permissible surface densities are included in a list attached. Permissible accumulative dose for the employees is the figure (unit rem) calculated by the formula D = 5(N-18), when D means permissible accumulative dose and N number of the age. Permissible exposure dose is 3 rem for 3 months for the employees, 1.5 rem for a year for persons other than the employees and 12 rem for the urgent work. Permissible densities for the employees, calculation of doses by interior exposure and permissible densities outside the inspected surrounding area are stipulated in detail with attached lists. (Okada, K.)

  18. Ionizing radiation, radiation sources, radiation exposure, radiation effects. Pt. 2

    International Nuclear Information System (INIS)

    Schultz, E.

    1985-01-01

    Part 2 deals with radiation exposure due to artificial radiation sources. The article describes X-ray diagnosis complete with an analysis of major methods, nuclear-medical diagnosis, percutaneous radiation therapy, isotope therapy, radiation from industrial generation of nucler energy and other sources of ionizing radiation. In conclusion, the authors attempt to asses total dose, genetically significant dose and various hazards of total radiation exposure by means of a summation of all radiation impacts. (orig./WU) [de

  19. Dose Record Analysis of External Exposure of Workers in Madagascar

    International Nuclear Information System (INIS)

    Andriambololona, R.; Ratovonjanahary, J. F.; Randriantsizafy, R. D.

    2004-01-01

    External personnel monitoring of workers in diagnostic radiology in Madagascar using thermoluminescence techniques has been studied in previous work for the period of 1990 to 2000. The study was based on the average of Hp(0.07) and Hp(10) and on the annual dose distribution. The results showed that mean doses are very low compared with the annual dose limits for workers of 20 mSv per year and are comparable with natural contribution of telluric X and gamma exposure which is evaluated as 3.21 mSv per year in Antananarivo. No trend in the average was observed, however, the last 4 years, the results showed a substantial decrease in the average from 2 mSv to 1 mSv. It was assumed that this was the impact of the implementation by radiation staff in their workplace of the in force regulation which is in compliance with the new basic safety standards. Indeed, since 1996, Madagascar-Institut National des Sciences et Techniques Nucleaires (Madagascar-INSTN) and the Association Nationale de Radioprotection de Madagascar (ANARAPMAD), the Madagascar radiation protection society and associate member of IRPA, set up a national program for training of radiation workers. The number of workers trained during this period is evaluated as 50% of the total number of radiation workers in Madagascar. The present work is a continuation of the above mentioned survey during the period of 2001 to 2003. The training program was upgraded to involve personnel who will be in charge of radiation protection and safety in workplace and the training cycle lasts 2 years instead of 3 days in the previous program. The survey has been extended to include all radiation workers in Madagascar though the medical field is still the main application and represents more than 90 percent of the latter. The results shows that for this last 3 years, an other substantial decrease from 1 mSv to 0.5 mSv was observed in the average. In the dose distribution, more than 98 percent of the Hp(0.07) and more than 99

  20. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low

  1. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  2. High Antigen Dose Is Detrimental to Post-Exposure Vaccine Protection against Tuberculosis

    Directory of Open Access Journals (Sweden)

    Rolf Billeskov

    2018-01-01

    Full Text Available Mycobacterium tuberculosis (Mtb, the etiologic agent of tuberculosis (TB, causes 1.8M deaths annually. The current vaccine, BCG, has failed to eradicate TB leaving 25% of the world’s population with latent Mtb infection (LTBI, and 5–10% of these people will reactivate and develop active TB. An efficient therapeutic vaccine targeting LTBI could have an enormous impact on global TB incidence, and could be an important aid in fighting multidrug resistance, which is increasing globally. Here we show in a mouse model using the H56 (Ag85B-ESAT-6-Rv2660 TB vaccine candidate that post-exposure, but not preventive, vaccine protection requires low vaccine antigen doses for optimal protection. Loss of protection from high dose post-exposure vaccination was not associated with a loss of overall vaccine response magnitude, but rather with greater differentiation and lower functional avidity of vaccine-specific CD4 T cells. High vaccine antigen dose also led to a decreased ability of vaccine-specific CD4 T cells to home into the Mtb-infected lung parenchyma, a recently discovered important feature of T cell protection in mice. These results underscore the importance of T cell quality rather than magnitude in TB-vaccine protection, and the significant role that antigen dosing plays in vaccine-mediated protection.

  3. Fourteenth annual report radiation exposures for DOE and DOE contractor employees - 1981

    International Nuclear Information System (INIS)

    1983-03-01

    All Department of Energy (DOE) and DOE contractors are required by DOE Order 5484.1, Chapter IV, to submit occupational exposure records to a central repository. The data required includes a summary of whole-body exposures to ionizing radiation, a summary of internal depositions of radioactive materials above specified limits, and occupational exposure reports for terminating employees. This report is a summary of the data submitted by DOE and DOE contractors for 1981. A total of 82,873 DOE and DOE contractor employees were monitored for whole-body ionizing radiation exposures in 1981. In addition to the employees, 84,343 visitors were monitored. Of all employees monitored, 54.43% received a dose equivalent that was less than measurable, 44.04% a measurable exposure less than 1 rem, and 1.53% an exposure granter than 1 rem. the exposure received by 88.14% of the visitors to DOE facilities was less than measurable. Only 11.85% of the visitors received a measurable exposure less than 1 rem, and 0.0% of the visitors received an exposure greater than 1 rem. No employees or visitors received a dose equivalent greater than 5 rem. The collective dose equivalent for DOE and DOE contractors employees was 6,902 person-rem. The collective dose equivalent for visitors was 579 person-rem. The total dose equivalent for employees and visitors combined was 7,481 person-rem. The average dose equivalent for all individuals (employees and visitors) monitored was 45 mrem and the average dose equivalent for all individuals who received a measurable exposure was 157 mrem. The highest average dose equivalent was observed for employees monitored at fuel processing facilities (342 mrem) and the lowest among visitors (7 mrem) to DOE facilities. These averages are significantly less than the DOE 5-rem/year radiation protection standard for whole-body exposures

  4. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  5. Estimated effective dose rates from radon exposure in workplaces and residences within Los Alamos county in New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Whicker, Jeffrey J [Los Alamos National Laboratory; Mcnaughton, Michael [Los Alamos National Laboratory

    2009-01-01

    Many millions of office workers are exposed to radon while at work and at home. Though there has been a multitude of studies reporting the measurements of radon concentrations and potential lung and effective doses associated with radon and progeny exposure in homes, similar studies on the concentrations and subsequent effective dose rates in the workplace are lacking. The purposes of this study were to measure radon concentrations in office and residential spaces in the same county and explore the radiation dose implications. Sixty-five track-etch detectors were deployed in office spaces and 47 were deployed in residences, all within Los Alamos County, New Mexico, USA. The sampling periods for these measurements were generally about three months. The measured concentrations were then used to calculate and compare effective dose rates resulting from exposure while at work and at home. Results showed that full-time office workers receive on average about nine times greater exposure at home than while in the office (691 mrem yr{sup -1} versus 78 mrem yr{sup -1}). The estimated effective dose rate for a more homebound person was 896 mrem yr{sup -1}. These effective dose rates are contrasted against the 100 mrem yr{sup -1} threshold for regulation of a 'radiological worker' defined in the Department of Energy regulations occupational exposure and the 10 mrem yr{sup -1} air pathway effective public dose limit regulated by the Environmental Protection Agency.

  6. A demonstration of dose modeling at Yucca Mountain

    International Nuclear Information System (INIS)

    Miley, T.B.; Eslinger, P.W.

    1992-11-01

    The U. S. Environmental Protection Agency is currently revising the regulatory guidance for high-level nuclear waste disposal. In its draft form, the guidelines contain dose limits. Since this is likely to be the case in the final regulations, it is essential that the US Department of Energy be prepared to calculate site-specific doses for any potential repository location. This year, Pacific Northwest Laboratory (PNL) has made a first attempt to estimate doses for the potential geologic repository at Yucca Mountain, Nevada as part of a preliminary total-systems performance assessment. A set of transport scenarios was defined to assess the cumulative release of radionuclides over 10,000 years under undisturbed and disturbed conditions at Yucca Mountain. Dose estimates were provided for several of the transport scenarios modeled. The exposure scenarios used to estimate dose in this total-systems exercise should not, however, be considered a definitive set of scenarios for determining the risk of the potential repository. Exposure scenarios were defined for waterborne and surface contamination that result from both undisturbed and disturbed performance of the potential repository. The exposure scenarios used for this analysis were designed for the Hanford Site in Washington. The undisturbed performance scenarios for which exposures were modeled are gas-phase release of 14 C to the surface and natural breakdown of the waste containers with waterborne release. The disturbed performance scenario for which doses were estimated is exploratory drilling. Both surface and waterborne contamination were considered for the drilling intrusion scenario

  7. Risk equivalent of exposure versus dose of radiation

    International Nuclear Information System (INIS)

    Bond, V.P.

    1986-01-01

    Radiation is perhaps unique among all agents of interest in the Health Sciences in that it alone is both a therapeutic agent for the control of cancer and an essentially ubiquitous environmental agent with a potential for increasing the cancer rate in human populations. Therapy of tumors is accomplished with the high-level exposure (HLE) to radiation in order to effect control or a cure. Thus, it conforms to the concepts and approaches of pharmacology, toxicology, and therapeutic medicine. Only one function, that which relates the object-oriented and nonstochastic independent variable organ dose to its effect on a cancer or an organ, is needed to estimate the probability, P 2 , of a quantal response. Only P 2 is needed because P 1 , that the cancer slated for such treatment will receive some amount of the agent and be affected to some degree, is effectively unity. The health problem involving low-level exposure (LLE) to radiation, in contrast, is not at all analogous to those of pharmacology, toxicology, and medicine. Rather, it presents a public health problem in that it is a health population, albeit of cells, that is exposed in a radiation field composed of moving radiation particles with some attendant low-order carcinogenic or mutagenic risk. Thus, the concepts, quantities, and terminology applied to low-level radiation must be modified from their present orientation toward pharmacology, toxicology, medicine, and dose to conform to those of public health and accident statistics, in which both P 1 and P 2 for the exposed cells must be estimated

  8. Chronic dietary exposure to a low-dose mixture of genistein and vinclozolin modifies the reproductive axis, testis transcriptome, and fertility.

    Science.gov (United States)

    Eustache, Florence; Mondon, Françoise; Canivenc-Lavier, Marie Chantal; Lesaffre, Corinne; Fulla, Yvonne; Berges, Raymond; Cravedi, Jean Pierre; Vaiman, Daniel; Auger, Jacques

    2009-08-01

    The reproductive consequences and mechanisms of action of chronic exposure to low-dose endocrine disruptors are poorly understood. We assessed the effects of a continuous, low-dose exposure to a phytoestrogen (genistein) and/or an antiandrogenic food contaminant (vinclozolin) on the male reproductive tract and fertility. Male rats were exposed by gavage to genistein and vinclozolin from conception to adulthood, alone or in combination, at low doses (1 mg/kg/day) or higher doses (10 and 30 mg/kg/day). We studied a number of standard reproductive toxicology end points and also assessed testicular mRNA expression profiles using long-oligonucleotide microarrays. The low-dose mixture and high-dose vinclozolin produced the most significant alterations in adults: decreased sperm counts, reduced sperm motion parameters, decreased litter sizes, and increased post implantation loss. Testicular mRNA expression profiles for these exposure conditions were strongly correlated. Functional clustering indicated that many of the genes induced belong to the "neuroactive ligand-receptor interactions" family encompassing several hormonally related actors (e.g., follicle-stimulating hormone and its receptor). All exposure conditions decreased the levels of mRNAs involved in ribosome function, indicating probable decreased protein production. Our study shows that chronic exposure to a mixture of a dose of a phytoestrogen equivalent to that in the human diet and a low dose-albeit not environmental-of a common anti-androgenic food contaminant may seriously affect the male reproductive tract and fertility.

  9. Effects on patient exposure dose and image quality by increasing focal film distance in abdominal radiography

    International Nuclear Information System (INIS)

    Kim, You Hyun; Kwon, Soo Il

    1998-01-01

    We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce thr patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowadays, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows ; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data

  10. A study on exposure dose from injection work and elution work for radiation workers and frequent workers in nuclear medicine

    International Nuclear Information System (INIS)

    Ju, Yong Jin; Chung, Woon Kwan; Dong, Kyung Rae; Choi, Eun Jin; Kwak, Jong Gil; Ryu, Jae Kwang

    2017-01-01

    Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a signifcant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity

  11. A study on exposure dose from injection work and elution work for radiation workers and frequent workers in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Yong Jin; Chung, Woon Kwan [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of); Choi, Eun Jin; Kwak, Jong Gil [Dept. of Public Health and Medicine, Dongshin University Graduate School, Naju (Korea, Republic of); Ryu, Jae Kwang [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-03-15

    Compared to other occupations, there is a greater risk of exposure to radiation due to the use of radioisotopes in nuclear medicine for diagnostic evaluations and therapy. To consider ways to reduce exposure dose for those in nuclear medicine involved in injection work and elution work among radiation workers as well as for sanitation workers and trainees among frequent workers an investigation into exposure dose and situational analysis from changes in yearly exposure dose evaluations, changes in work environment and changes in forms of inspection were conducted. Exposure dose measurements were taken by using EPD MK2 worn during working hours for one injection worker, one elution worker, two sanitation workers, and one trainee at a general hospital in the Seoul area for three days from July 18th to 20th 2016. Radiation from radioisotopes which are a part of nuclear medicine can significantly affect not only radiation workers who deal with radioisotopes directly but also frequency works as well. According to this study the annual dose limit for elution workers and injection workers were considered safe as the amount of exposure was not large enough to have a signifcant effect. The limits of this study consist in the duration of this study and the quantity of participants. Also there was a limitation of the measurement device involving accumulated exposure, where the EPD MK2 cannot check the changes in exposure according to a particular activity.

  12. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  13. Ratios between effective doses for tomographic and mathematician models due to internal exposure of photons

    International Nuclear Information System (INIS)

    Lima, F.R.A.; Kramer, R.; Khoury, H.J.; Santos, A.M.; Loureiro, E.C.M.

    2005-01-01

    The development of new and sophisticated Monte Carlo codes and tomographic human phantoms or voxels motivated the International Commission on Radiological Protection (ICRP) to revise the traditional models of exposure, which have been used to calculate effective dose coefficients for organs and tissues based on mathematician phantoms known as MIRD5. This paper shows the results of calculations using tomographic phantoms MAX (Male Adult voXel) and FAX (Female Adult voXel), recently developed by the authors as well as with the phantoms ADAM and EVA, of specific genres, type MIRD5, coupled to the EGS4 Monte Carlo and MCNP4C codes, for internal exposure with photons of energies between 10 keV and 4 MeV to several organs sources. Effective Doses for both models, tomographic and mathematician, will be compared separately as a function of the Monte Carlo code replacement, of compositions of human tissues and the anatomy reproduced through tomographs. The results indicate that for photon internal exposure, the use of models of exposure based in voxel, increases the values of effective doses up to 70% for some organs sources considered in this study, when compared with the corresponding results obtained with phantoms of MIRD-5 type

  14. Dose-dependent in vivo cell-cycle changes following radon progeny exposure

    International Nuclear Information System (INIS)

    Johnson, N.F.; Carpenter, T.R.; Hickman, A.W.; Jaramillo, R.J.; Gurule, D.M.

    1994-01-01

    Exposures to low concentrations of alpha-emitting radon progeny are reported by the U.S. Environmental Protection Agency to be the second leading cause of lung cancer. Current risk estimates for lung cancer from the inhalation of radon progeny are based on data from underground uranium miners. To produce such risk estimates, calculations are based on several assumptions concerning exposure-response relationships rather than dose-response relationships. A better understanding of the mechanisms of interactions between alpha particles, the cells of the respiratory tract, and the progression toward cancer may validate the mathematical models used to derive risk estimates

  15. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  16. Measuring radiation exposure during percutaneous drainages: can shoulder dosemeters be used to estimate finger doses?

    International Nuclear Information System (INIS)

    Vehmas, Tapio; Tikkanen, Heikki

    1992-01-01

    To assess the need for extra finger dosemeters, radiologists' and assistants' radiation exposure at both shoulders and at the third fingers of both hands were recorded using thermoluminescent dosemeters during 27 interventional drainage procedures. Under couch screening was used. Mean dose rates were calculated by dividing dose by screening time. The radiologists' bilateral finger dose rates did not correlate with each other; nor did dose rates between the left shoulder and the right hand. The radiologists' dose rates at both shoulders, correlated with each other, as did shoulder dose rates with dose rates at the ispilateral hand. The right shoulder dose rates correlated with the left hand dose rates. The assistants' dose rates at places of measurement showed significant correlations with each other. (Author)

  17. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  18. Low dose ionizing radiation exposure and cardiovascular disease mortality: cohort study based on Canadian national dose registry of radiation workers

    International Nuclear Information System (INIS)

    Zielinski, J. M.; Band, P. R.; Ashmore, P. J.; Jiang, H.; Shilnikova, N. S.; Tait, V. K.; Krewski, D.

    2009-01-01

    The purpose of our study was to assess the risk of cardiovascular disease (CVD) mortality in a Canadian cohort of 337 397 individuals (169 256 men and 168 141 women) occupationally exposed to ionizing radiation and included in the National Dose Registry (NDR) of Canada. Material and Methods: Exposure to high doses of ionizing radiation, such as those received during radiotherapy, leads to increased risk of cardiovascular diseases. The emerging evidence of excess risk of CVDs after exposure to doses well below those previously considered as safe warrants epidemiological studies of populations exposed to low levels of ionizing radiation. In the present study, the cohort consisted of employees at nuclear power stations (nuclear workers) as well as medical, dental and industrial workers. The mean whole body radiation dose was 8.6 mSv for men and 1.2 mSv for women. Results: During the study period (1951 - 1995), as many as 3 533 deaths from cardiovascular diseases have been identified (3 018 among men and 515 among women). In the cohort, CVD mortality was significantly lower than in the general population of Canada. The cohort showed a significant dose response both among men and women. Risk estimates of CVD mortality in the NDR cohort, when expressed as excess relative risk per unit dose, were higher than those in most other occupational cohorts and higher than in the studies of Japanese atomic bomb survivors. Conclusions: The study has demonstrated a strong positive association between radiation dose and the risk of CVD mortality. Caution needs to be exercised when interpreting these results, due to the potential bias introduced by dosimetry uncertainties, the possible record linkage errors, and especially by the lack of adjustment for non-radiation risk factors. (authors)

  19. Updated radiological dose assessment of Bikini and Eneu Islands at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Stuart, M.L.; Thompson, S.E.; Conrado, C.L.; Stoker, A.C.

    1982-01-01

    This report is part of a continuing effort to refine dose assessments for resettlement options at Bikini Atoll. Radionuclide concentration data developed at Bikini Atoll since 1977 have been used in conjunction with recent dietary information and current dose models to develop the annual dose rate and 30- and 50-y integral doses presented here for Bikini and Eneu Island living patterns. The terrestrial food chain is the most significant exposure pathway--it contributes more than 50% of the total dose--and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation. Cesium-137 produces more than 85% of the predicted dose; 90 Sr is the second most significant radionuclide; 60 Co contributes to the external gamma exposure in varying degrees, but is a small part of the total predicted dose; the transuranic radionuclides contribute a small portion of the total predicted lung and bone doses but do present a long-term source of exposure. Maximum annual dose rates for Bikini Island are about 1 rem/y for the whole body and bone marrow when imported foods are available and about 1.9 rem/y when imports are unavailable. Maximum annual dose rates for Eneu Island when imports are available are 130 mrem/y for the whole body and 136 mrem/y for bone marrow. Similar doses when imported foods are unavailable are 245 and 263 mrem/y, respectively. The 30-y integral doses for Bikini Island are about 23 rem for whole body and bone marrow when imported foods are available and more than 40 rem when imports are unavailable. The Eneu Island 30-y integral doses for whole body and bone marrow are about 3 rem when imports are available and 5.5 and 6.1 rem, respectively, when imports are unavailable. Doses from living patterns involving some combination of Bikini and Eneu Islands fall between the doses listed above for each island separately

  20. 10 CFR 835.203 - Combining internal and external equivalent doses.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Combining internal and external equivalent doses. 835.203 Section 835.203 Energy DEPARTMENT OF ENERGY OCCUPATIONAL RADIATION PROTECTION Standards for Internal and External Exposure § 835.203 Combining internal and external equivalent doses. (a) The total effective dose...

  1. PBDE exposure from food in Ireland: optimising data exploitation in probabilistic exposure modelling.

    Science.gov (United States)

    Trudel, David; Tlustos, Christina; Von Goetz, Natalie; Scheringer, Martin; Hungerbühler, Konrad

    2011-01-01

    Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants added to plastics, polyurethane foam, electronics, textiles, and other products. These products release PBDEs into the indoor and outdoor environment, thus causing human exposure through food and dust. This study models PBDE dose distributions from ingestion of food for Irish adults on congener basis by using two probabilistic and one semi-deterministic method. One of the probabilistic methods was newly developed and is based on summary statistics of food consumption combined with a model generating realistic daily energy supply from food. Median (intermediate) doses of total PBDEs are in the range of 0.4-0.6 ng/kg(bw)/day for Irish adults. The 97.5th percentiles of total PBDE doses lie in a range of 1.7-2.2 ng/kg(bw)/day, which is comparable to doses derived for Belgian and Dutch adults. BDE-47 and BDE-99 were identified as the congeners contributing most to estimated intakes, accounting for more than half of the total doses. The most influential food groups contributing to this intake are lean fish and salmon which together account for about 22-25% of the total doses.

  2. X-ray exposure dose for the gonadal gland by the examination of computerized tomography and its protection

    International Nuclear Information System (INIS)

    Moriuchi, Iwao; Kaiya, Hisanori; Hirata, Toshifumi; Asada, Shuichi

    1978-01-01

    Computerized tomography (CT) is very useful for neuroradiological examination, and so it may possibly be used for screening tests. But x-ray exposure dose by a examination of CT is considerable, especially for the male gonadal gland. This study showed that the dose from a complete CT examination of 10 - 15 scans for a male gonadal gland was about 1,800 times more than a single plain neuroradiography. But by only a 0.07 mm lead equivalent protecter, the exposure dose resulting from CT for a gonadal gland could be reduced to 0.0 mrad. (auth.)

  3. The Dose Response Relationship between In Ear Occupational Noise Exposure and Hearing Loss

    Science.gov (United States)

    Rabinowitz, Peter M.; Galusha, Deron; Dixon-Ernst, Christine; Clougherty, Jane E.; Neitzel, Richard L.

    2014-01-01

    Objectives Current understanding of the dose-response relationship between occupational noise and hearing loss is based on cross-sectional studies prior to the widespread use hearing protection and with limited data regarding noise exposures below 85dBA. We report on the hearing loss experience of a unique cohort of industrial workers with daily monitoring of noise inside of hearing protection devices. Methods At an industrial facility, workers exhibiting accelerated hearing loss were enrolled in a mandatory program to monitor daily noise exposures inside of hearing protection. We compared these noise measurements (as time-weighted LAVG) to interval rates of high frequency hearing loss over a six year period using a mixed effects model, adjusting for potential confounders. Results Workers’ high frequency hearing levels at study inception averaged more than 40 dB hearing threshold level (HTL). Most noise exposures were less than 85dBA (mean LAVG 76 dBA, interquartile range 74 to 80 dBA). We found no statistical relationship between LAvg and high frequency hearing loss (p = 0.53). Using a metric for monthly maximum noise exposure did not improve model fit. Conclusion At-ear noise exposures below 85dBA did not show an association with risk of high frequency hearing loss among workers with substantial past noise exposure and hearing loss at baseline. Therefore, effective noise control to below 85dBA may lead to significant reduction in occupational hearing loss risk in such individuals. Further research is needed on the dose response relationship of noise and hearing loss in individuals with normal hearing and little prior noise exposure. PMID:23825197

  4. Occupational Doses and the Contribution to the Population Dose in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Han, Seung Jae; Kyu, Hwan Jeong [KINS, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  5. Occupational Doses and the Contribution to the Population Dose in Korea

    International Nuclear Information System (INIS)

    Han, Seung Jae; Kyu, Hwan Jeong

    2016-01-01

    The purpose of this study is to evaluate the occupational exposure records in terms of the control of exposure for radiation workers and dose reduction. The study includes the estimates of the number of people exposed occupationally, the effective collective doses and mean doses to those exposed. In addition, the study includes an estimate of the contribution of occupational exposure to the Korean population dose. The exposure of radiation workers in occupational field includes medical radiology, industrial applications such as radiography, nuclear power, and some research activities. Occupational exposure from medical radiology practices includes the contributions from diagnostic x-ray procedures, dental radiography, nuclear medicine and radiation therapy. The control of exposure for radiation workers, and the measures necessary to maintain radiation exposure as low as reasonably achievable (ALARA) are specified in Subparagraph 3 and Subparagraph 4 of Article 91 (1) of the Korea Nuclear Safety Act (KNSA), respectively. Therefore, from a regulatory perspective, the exposure data of the workers are primarily for verification of the adequacy of the control of exposure, radiation protection and implementation of ALARA. The number of people exposed occupationally, the effective collective doses and mean doses to those exposed, and average effective doses from occupational exposure during the period of 2009 to 2013 have been evaluated. In general, radiation workers were increasing in number annually, but the mean doses for those exposed each year showed the control of exposures were mostly considered met within the dose limit in KNSA. Nevertheless, it was shown that the continuous efforts would be needed to reduce doses and thus to implement ALARA regulatory requirements. In radiation occupations, the application of ICRP radiation protection principles will ensure good practice and decreasing exposures. Over the period of 5 years, the contributions of the annual

  6. Total dose induced latch in short channel NMOS/SOI transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Quoizola, S.; Musseau, O.; Flament, O.; Leray, J.L.; Pelloie, J.L.; Raynaud, C.; Faynot, O.

    1998-01-01

    A latch effect induced by total dose irradiation is observed in short channel SOI transistors. This effect appears on NMOS transistors with either a fully or a partially depleted structure. It is characterized by a hysteresis behavior of the Id-Vg characteristics at high drain bias for a given critical dose. Above this dose, the authors still observe a limited leakage current at low drain bias (0.1 V), but a high conduction current at high drain bias (2 V) as the transistor should be in the off-state. The critical dose above which the latch appears strongly depends on gate length, transistor structure (fully or partially depleted), buried oxide thickness and supply voltage. Two-dimensional (2D) numerical simulations indicate that the parasitic condition is due to the latch of the back gate transistor triggered by charge trapping in the buried oxide. To avoid the latch induced by the floating body effect, different techniques can be used: doping engineering, body contacts, etc. The study of the main parameters influencing the latch (gate length, supply voltage) shows that the scaling of technologies does not necessarily imply an increased latch sensitivity. Some technological parameters like the buried oxide hardness and thickness can be used to avoid latch, even at high cumulated dose, on highly integrated SOI technologies

  7. Enhanced natural radiation exposure enhanced by human activity: the largest contributor to the Chinese population dose

    International Nuclear Information System (INIS)

    Pan Ziqiang; Liu Yanyang

    2011-01-01

    For the radiation exposure caused by human activities, the enhanced natural radiation exposure is the largest contributor to Chinese population dose. This problem has attracted social attention in recent years. Efforts have been made in several fields, such as radon indoors and in workplace, environmental problems associated with NORMs, occupational radiation hazards of non-uranium mine, and radiation dose evaluation for energy chain, but there are still many problems to be solved. In order to protect the health of workers and the public, while ensuring industrial production and economic development, it is also necessary to continue to strengthen research in all aspects above mentioned, and gradually promote the control of natural radiation exposure enhanced by human activities. (authors)

  8. Low dose perfluorooctanoate exposure promotes cell proliferation in a human non-tumor liver cell line

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongxia; Cui, Ruina [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Beijing 100101 (China); Guo, Xuejiang [State Key Laboratory of Reproductive Medicine, Nanjing Medical University, Nanjing 210029 (China); Hu, Jiayue [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Beijing 100101 (China); Dai, Jiayin, E-mail: daijy@ioz.ac.cn [Key Laboratory of Animal Ecology and Conservation Biology, Institute of Zoology, Chinese Academy of Sciences, Beijing 100101 (China)

    2016-08-05

    Highlights: • Differential expression of proteins induced by PFOA in HL-7702 was identified. • Most of the differentially expressed proteins are related to cell proliferation. • A low dose of PFOA stimulates HL-7702 cell proliferation. • A high dose of PFOA inhibits HL-7702 cell proliferation. - Abstract: Perfluorooctanoate (PFOA) is a well-known persistent organic pollutant widely found in the environment, wildlife and humans. Medical surveillance and experimental studies have investigated the potential effects of PFOA on human livers, but the hepatotoxicity of PFOA on humans and its underlying mechanism remain to be clarified. We exposed a human liver cell line (HL-7702) to 50 μM PFOA for 48 h and 96 h, and identified 111 significantly differentially expressed proteins by iTRAQ analysis. A total of 46 proteins were related to cell proliferation and apoptosis. Through further analysis of the cell cycle, apoptosis and their related proteins, we found that low doses of PFOA (50–100 μM) promoted cell proliferation and numbers by promoting cells from the G1 to S phases, whereas high doses of PFOA (200–400 μM) led to reduced HL-7702 cell numbers compared with that of the control mainly due to cell cycle arrest in the G0/G1 phase. To our knowledge, this is the first report on the promotion of cell cycle progression in human cells following PFOA exposure.

  9. Low dose perfluorooctanoate exposure promotes cell proliferation in a human non-tumor liver cell line

    International Nuclear Information System (INIS)

    Zhang, Hongxia; Cui, Ruina; Guo, Xuejiang; Hu, Jiayue; Dai, Jiayin

    2016-01-01

    Highlights: • Differential expression of proteins induced by PFOA in HL-7702 was identified. • Most of the differentially expressed proteins are related to cell proliferation. • A low dose of PFOA stimulates HL-7702 cell proliferation. • A high dose of PFOA inhibits HL-7702 cell proliferation. - Abstract: Perfluorooctanoate (PFOA) is a well-known persistent organic pollutant widely found in the environment, wildlife and humans. Medical surveillance and experimental studies have investigated the potential effects of PFOA on human livers, but the hepatotoxicity of PFOA on humans and its underlying mechanism remain to be clarified. We exposed a human liver cell line (HL-7702) to 50 μM PFOA for 48 h and 96 h, and identified 111 significantly differentially expressed proteins by iTRAQ analysis. A total of 46 proteins were related to cell proliferation and apoptosis. Through further analysis of the cell cycle, apoptosis and their related proteins, we found that low doses of PFOA (50–100 μM) promoted cell proliferation and numbers by promoting cells from the G1 to S phases, whereas high doses of PFOA (200–400 μM) led to reduced HL-7702 cell numbers compared with that of the control mainly due to cell cycle arrest in the G0/G1 phase. To our knowledge, this is the first report on the promotion of cell cycle progression in human cells following PFOA exposure.

  10. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  11. CONDOS-II, Radiation Dose from Consumer Product Distribution Chain

    International Nuclear Information System (INIS)

    1984-01-01

    1 - Description of problem or function: This code was developed under sponsorship of the Nuclear Regulatory Commission to serve as a tool for assessing radiation doses that may be associated with consumer products that contain radionuclides. The code calculates radiation dose equivalents resulting from user-supplied scenarios of exposures to radionuclides contained in or released from sources that contain radionuclides. Dose equivalents may be calculated to total body, skin surface, skeletal bone, testes, ovaries, liver, kidneys, lungs, and maximally exposed segments of the gastrointestinal tract from exposures via (1) direct, external irradiation by photons (including Bremsstrahlung) emitted from the source, (2) external irradiation by photons during immersion in air containing photon-emitting radionuclides that have escaped from the source, (3) internal exposures by all radiations emitted by inhaled radionuclides that have escaped from the source, and (4) internal exposures by all radiations emitted by ingested radionuclides that have escaped from the source. 2 - Method of solution: Organ dose equivalents are approximated in two ways, depending on the exposure type. For external exposures, energy specific organ-to-skin-surface dose conversion ratios are used to approximate dose equivalents to specific organs from doses calculated to a point on the skin surface. The organ-to-skin ratios are incorporated in organ- and nuclide-specific dose rate factors, which are used to approximate doses during immersion in contaminated air. For internal exposures, 50 year dose equivalents are calculated using organ- and nuclide-specific, 50 year dose conversion factors. Doses from direct, external exposures are calculated using the energy-specific dose conversion ratios, user supplied exposure conditions, and photon flux approximations for eleven source geometries. Available source geometries include: point, shielded and unshielded; line, shielded and unshielded; disk, shielded

  12. Reevaluation of time spent indoors used for exposure dose assessment

    International Nuclear Information System (INIS)

    Hirose, Katsumi; Fujimoto, Kenzo

    2016-01-01

    A time spent indoors of sixteen hours per day (indoor occupancy factor: 0.67) has been used to assess the radiation dose of residents who spend daily life in the area contaminated due to the nuclear accident in Japan. However, much longer time is considered to be spent indoors for recent modern life. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has been used an indoor occupancy factor of 0.8 since 1977 and a few reports suggested much higher indoor occupancy factors. Therefore it is important to reevaluate the indoor occupancy factor using current available survey data in Japan, such as 'NHK 2010 National Time Use Survey' and 'Survey on Time Use and Leisure Activities' of Statistics Bureau with certain assumption of time spent indoors in each daily activity. The total time spent indoors in a day is calculated to be 20.2 hours and its indoor occupancy factor is 0.84. Much lower indoor occupancy factors were derived from the survey data by Statistics Bureau for 10 to 14 and 15 to 19 years old groups and farmers who spend most of their time outdoors although present estimated indoor occupancy factor of 0.84 is still lower than those found in some of the relevant reports. A rounded indoor occupancy factor of 0.80 might be the appropriate conservative reference value to be used for the dose estimation of people who live in radioactively contaminated areas and for other relevant purposes of exposure assessment, taken into consideration the present results and values reported in United States Environmental Protection Agency (US EPA) and UNSCEAR. (author)

  13. Consequences of the exposure at low dose rates-contribution of animal experimentation. Consequences de l'exposition aux faibles debits de dose. Apport de l'experimentation animale

    Energy Technology Data Exchange (ETDEWEB)

    Masse, R. (CEA Centre d' Etudes de Fontenay-aux-Roses, 92 (FR). Direction des Sciences du Vivant)

    1990-01-01

    The exposure of laboratory animals to the various types of radiations will induce cancers in relation with the tissue absorbed doses. The shape of the dose-effet relationship is most variable. It is important to distinguish which tumours are comparable to human tumours. Those showing more analogies answer but seldom to the classical lineo-quadratic relationship; however, a strong attenuation of induction is demonstrated at low dose rates. Quasi-threshold relationships are seen after the exposure of some tissues to high-LET radiations. These observations question the validity of generalizing the radiobiologists' dual action theory, setting the origin of the dose-effect relationship in the induction of events within the DNA molecule. There is an alternative in the cellular collaboration events; it assumes that the effectiveness per dose unit decreases constantly as an inverse function of the dose rate.

  14. Radiation doses and cancer risks in the Marshall Islands associated with exposure to radioactive fallout from Bikini and Enewetak nuclear weapons tests: summary.

    Science.gov (United States)

    Simon, Steven L; Bouville, André; Land, Charles E; Beck, Harold L

    2010-08-01

    Nuclear weapons testing conducted at Bikini and Enewetak Atolls during 1946-1958 resulted in exposures of the resident population of the present-day Republic of the Marshall Islands to radioactive fallout. This paper summarizes the results of a thorough and systematic reconstruction of radiation doses to that population, by year, age at exposure, and atoll of residence, and the related cancer risks. Detailed methods and results are presented in a series of companion papers in this volume. From our analysis, we concluded that 20 of the 66 nuclear tests conducted in or near the Marshall Islands resulted in measurable fallout deposition on one or more of the inhabited atolls of the Marshall Islands. In this work, we estimated deposition densities (kBq m(-2)) of all important dose-contributing radionuclides at each of the 32 atolls and separate reef islands of the Marshall Islands. Quantitative deposition estimates were made for 63 radionuclides from each test at each atoll. Those estimates along with reported measurements of exposure rates at various times after fallout were used to estimate radiation absorbed doses to the red bone marrow, thyroid gland, stomach wall, and colon wall of atoll residents from both external and internal exposure. Annual doses were estimated for six age groups ranging from newborns to adults. We found that the total deposition of 137Cs, external dose, internal organ doses, and cancer risks followed the same geographic pattern with the large population of the southern atolls receiving the lowest doses. Permanent residents of the southern atolls who were of adult age at the beginning of the testing period received external doses ranging from 5 to 12 mGy on average; the external doses to adults at the mid-latitude atolls ranged from 22 to 59 mGy on average, while the residents of the northern atolls received external doses in the hundreds to over 1,000 mGy. Internal doses varied significantly by age at exposure, location, and organ. Except

  15. Application of maximum values for radiation exposure and principles for the calculation of radiation dose

    International Nuclear Information System (INIS)

    2000-01-01

    The guide sets out the mathematical definitions and principles involved in the calculation of the equivalent dose and the effective dose, and the instructions concerning the application of the maximum values of these quantities. further, for monitoring the dose caused by internal radiation, the guide defines the limits derived from annual dose limits (the Annual Limit on Intake and the Derived Air Concentration). Finally, the guide defines the operational quantities to be used in estimating the equivalent dose and the effective dose, and also sets out the definitions of some other quantities and concepts to be used in monitoring radiation exposure. The guide does not include the calculation of patient doses carried out for the purposes of quality assurance

  16. Application of maximum values for radiation exposure and principles for the calculation of radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The guide sets out the mathematical definitions and principles involved in the calculation of the equivalent dose and the effective dose, and the instructions concerning the application of the maximum values of these quantities. further, for monitoring the dose caused by internal radiation, the guide defines the limits derived from annual dose limits (the Annual Limit on Intake and the Derived Air Concentration). Finally, the guide defines the operational quantities to be used in estimating the equivalent dose and the effective dose, and also sets out the definitions of some other quantities and concepts to be used in monitoring radiation exposure. The guide does not include the calculation of patient doses carried out for the purposes of quality assurance.

  17. Neuropsychological effects of chronic low-dose exposure to polychlorinated biphenyls (PCBs: A cross-sectional study

    Directory of Open Access Journals (Sweden)

    Klett Martin

    2005-10-01

    Full Text Available Abstract Background Exposure to indoor air of private or public buildings contaminated with polychlorinated biphenyls (PCBs has raised health concerns in long-term users. This exploratory neuropsychological group study investigated the potential adverse effects of chronic low-dose exposure to specific air-borne low chlorinated PCBs on well-being and behavioral measures in adult humans. Methods Thirty employees exposed to indoor air contaminated with PCBs from elastic sealants in a school building were compared to 30 non-exposed controls matched for education and age, controlling for gender (age range 37–61 years. PCB exposure was verified by external exposure data and biological monitoring (PCB 28, 101, 138, 153, 180. Subjective complaints, learning and memory, executive function, and visual-spatial function was assessed by standardized neuropsychological testing. Since exposure status depended on the use of contaminated rooms, an objectively exposed subgroup (N = 16; PCB 28 = 0.20 μg/l; weighted exposure duration 17.9 ± 7 years was identified and compared with 16 paired controls. Results Blood analyses indicated a moderate exposure effect size (d relative to expected background exposure for total PCB (4.45 ± 2.44 μg/l; d = 0.4. A significant exposure effect was found for the low chlorinated PCBs 28 (0.28 ± 0.25 μg/l; d = 1.5 and 101 (0.07 ± 0.09 μg/l; d = 0.7. Although no neuropsychological effects exceeded the adjusted significance level, estimation statistics showed elevated effect sizes for several variables. The objectively exposed subgroup showed a trend towards increased subjective attentional and emotional complaints (tiredness and slowing of practical activities, emotional state as well as attenuated attentional performance (response shifting and alertness in a cued reaction task. Conclusion Chronic inhalation of low chlorinated PCBs that involved elevated blood levels was associated with a subtle attenuation of emotional well

  18. Facial exposure dose assessment during intraoral radiography by radiological technologists

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hwan; Yang, Han Joon [Dept. of International Radiological Science, Hallym University of Graduate Studies, Chuncheon (Korea, Republic of)

    2014-09-15

    The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60 kVp, 10 mA, 50 msec) and for children (60 kVp, 10 mA, 20 msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10 cm, 15 cm, 20 cm, 25 cm, 30 cm, 35 cm, and 40 cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40 cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10 cm under the adult conditions. The rate at the distance of 40 cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10 cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

  19. Exposure doses of the patient and the medical staff during urological X-ray examens

    International Nuclear Information System (INIS)

    Vogel, H.; Loehr, H.; Haug, P.; Schuett, B.

    1977-01-01

    During 32 intravenous urografies and 48 angiografies of the kidney and the suprarenal glands the X-ray doses at the patient's skin and gonades were determined. During the angiografies the doses were mesured at the hands. the gonades and the front (eyes) of the medical staff. The results are discussed. Because the X-ray doses are relatively high, the number of the pictures and the exposure time is to be reduced to the minimum. Clinical experience and special knowledge is the best X-ray protection. (orig.) [de

  20. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

    Science.gov (United States)

    Lee, Kisung; Lee, Kyoung Min; Park, Moon Seok; Lee, Boram; Kwon, Dae Gyu; Chung, Chin Youb

    2012-06-15

    Measurement of radiation dose from C-arm fluoroscopy during a simulated intraoperative use in spine surgery. OBJECTIVE.: To investigate scatter radiation doses to specific organs of surgeons during intraoperative use of C-arm fluoroscopy in spine surgery and to provide practical intraoperative guidelines. There have been studies that reported the radiation dose of C-arm fluoroscopy in various procedures. However, radiation doses to surgeons' specific organs during spine surgery have not been sufficiently examined, and the practical intraoperative radioprotective guidelines have not been suggested. Scatter radiation dose (air kerma rate) was measured during the use of a C-arm on an anthropomorphic chest phantom on an operating table. Then, a whole body anthropomorphic phantom was located besides the chest phantom to simulate a surgeon, and scatter radiation doses to specific organs (eye, thyroid, breast, and gonads) and direct radiation dose to the surgeon's hand were measured using 4 C-arm configurations (standard, inverted, translateral, and tube translateral). The effects of rotating the surgeon's head away from the patient and of a thyroid shield were also evaluated. Scatter radiation doses decreased as distance from the patient increased during C-arm fluoroscopy use. The standard and translateral C-arm configurations caused lower scatter doses to sensitive organs than inverted and tube translateral configurations. Scatter doses were highest for breast and lowest for gonads. The use of a thyroid shield and rotating the surgeon's head away from the patient reduced scatter radiation dose to the surgeon's thyroid and eyes. The direct radiation dose was at least 20 times greater than scatter doses to sensitive organs. The following factors could reduce radiation exposure during intraoperative use of C-arm; (1) distance from the patient, (2) C-arm configuration, (3) radioprotective equipments, (4) rotating the surgeons' eyes away from the patient, and (5) avoiding

  1. Radiation dose control in the mining of high grade uranium ores

    International Nuclear Information System (INIS)

    Webster, S.T.; Brown, L.D.

    1996-01-01

    The control of radiation doses received by uranium miners is an unusually complex procedure, as three separate components of their total effective dose may be significant and may have to be evaluated separately. Apart from external and internal doses evaluated in the usual way, it is also necessary to evaluate the inhalation dose from radon progeny separately. Although this essentially forms part of the internal dose received, it is not evaluated in the conventional way since the associated dose equivalent must be derived from conversion factors based on epidemiological studies, instead of by the usual approach of calculating the dose to tissue from the inhaled activity and multiplying this by a recognized conversion factor to derive a whole body effective dose. Historically the traditional unit used for monitoring the concentration of radon progeny in a workplace is the Working Level (WL), this is now defined as a concentration such that the potential alpha emission from all the short lived progeny present in the sample will total 1.3 x 108 MeV per m 3 . The corresponding unit of exposure is the Working Level Month (WLM) and is the exposure that would be received by a reference man working in such an atmosphere for a standard working month lasting 170 hours. Unfortunately the relationship between exposures, measured in WLM, and the conventional radiation dose to the target tissues is complex and calculated values depend greatly upon the assumptions made in the lung model that must be used. Risks are therefore still controlled by limiting exposures in WLM on the basis of epidemiological studies of lung cancer incidence among miners employed at a time when the magnitude of the risk was not fully appreciated, and cancer incidence was high enough to permit reasonably accurate risk estimates to be derived directly from exposures in WLM. (author)

  2. Dose-rate models for human survival after exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1987-01-01

    This paper reviews new estimates of the LD 50 in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD 50 s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively

  3. Dose-rate models for human survival after exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1986-01-01

    This paper reviews new estimates of the L 50 in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD 50 s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively

  4. High-pitch computed tomography coronary angiography-a new dose-saving algorithm: estimation of radiation exposure.

    Science.gov (United States)

    Ketelsen, Dominik; Buchgeister, Markus; Korn, Andreas; Fenchel, Michael; Schmidt, Bernhard; Flohr, Thomas G; Thomas, Christoph; Schabel, Christoph; Tsiflikas, Ilias; Syha, Roland; Claussen, Claus D; Heuschmid, Martin

    2012-01-01

    Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medical Solutions, Germany). The following scan parameters were used: 320 mAs per rotation, 100 and 120 kV, pitch 3.4 for prospectively ECG-triggered high-pitch CTCA, scan range of 13.5 cm, collimation 64 × 2 × 0.6 mm with z-flying focal spot, gantry rotation time 280 ms, and simulated heart rate of 60 beats per minute. Results. Depending on the applied tube potential, the effective whole-body dose of the cardiac scan ranged from 1.1 mSv to 1.6 mSv and from 1.2 to 1.8 mSv for males and females, respectively. The radiosensitive breast tissue in the range of the primary beam caused an increased female-specific effective dose of 8.6%±0.3% compared to males. Decreasing the tube potential, a significant reduction of the effective dose of 35.8% and 36.0% can be achieved for males and females, respectively (P < 0.001). Conclusion. The radiologist and the CT technician should be aware of this new dose-saving strategy to keep the radiation exposure as low as reasonablly achievable.

  5. Low-dose effect of developmental bisphenol A exposure on sperm count and behaviour in rats

    DEFF Research Database (Denmark)

    Hass, Ulla; Christiansen, Sofie; Boberg, Julie

    2016-01-01

    /day. In the offspring, growth, sexual maturation, weights and histopathology of reproductive organs, oestrus cyclicity and sperm counts were assessed. Neurobehavioural development was investigated using a behavioural testing battery including tests for motor activity, sweet preference, anxiety and spatial learning....... Decreased sperm count was found at the lowest bisphenol A dose, that is 25 μg/kg/day, but not at the higher doses. Reproductive organ weight and histology were not affected and no behavioural effects were seen in male offspring. In the female offspring, exposure to 25 μg/kg bw/day bisphenol A dose resulted...... not significantly affected. In conclusion, the present study using a robust experimental study design, has shown that developmental exposure to 25 μg/kg bw/day bisphenol A can cause adverse effects on fertility (decreased sperm count), neurodevelopment (masculinization of spatial learning in females) and lead...

  6. Breast cancer incidence following low-dose rate environmental exposure: Techa River Cohort, 1956–2004

    Science.gov (United States)

    Ostroumova, E; Preston, D L; Ron, E; Krestinina, L; Davis, F G; Kossenko, M; Akleyev, A

    2008-01-01

    In the 1950s, the Mayak nuclear weapons facility in Russia discharged liquid radioactive wastes into the Techa River causing exposure of riverside residents to protracted low-to-moderate doses of radiation. Almost 10 000 women received estimated doses to the stomach of up to 0.47 Gray (Gy) (mean dose=0.04 Gy) from external γ-exposure and 137Cs incorporation. We have been following this population for cancer incidence and mortality and as in the general Russian population, we found a significant temporal trend of breast cancer incidence. A significant linear radiation dose–response relationship was observed (P=0.01) with an estimated excess relative risk per Gray (ERR/Gy) of 5.00 (95% confidence interval (CI), 0.80, 12.76). We estimated that approximately 12% of the 109 observed cases could be attributed to radiation. PMID:19002173

  7. Estimation of radiation exposure from lung cancer screening program with low-dose computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Yeon; Jun, Jae Kwan [Graduate School of Cancer Science and Policy, National Cancer Center, Seoul (Korea, Republic of)

    2016-12-15

    The National Lung Screening Trial (NLST) demonstrated that screening with Low-dose Computed Tomography (LDCT) screening reduced lung cancer mortality in a high-risk population. Recently, the United States Preventive Services Task Force (USPSTF) gave a B recommendation for annual LDCT screening for individuals at high-risk. With the promising results, Korea developed lung cancer screening guideline and is planning a pilot study for implementation of national lung cancer screening. With widespread adoption of lung cancer screening with LDCT, there are concerns about harms of screening, including high false-positive rates and radiation exposure. Over the 3 rounds of screening in the NLST, 96.4% of positive results were false-positives. Although the initial screening is performed at low dose, subsequent diagnostic examinations following positive results additively contribute to patient's lifetime exposure. As with implementing a large-scale screening program, there is a lack of established risk assessment about the effect of radiation exposure from long-term screening program. Thus, the purpose of this study was to estimate cumulative radiation exposure of annual LDCT lung cancer screening program over 20-year period.

  8. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  9. The study on the image quality and patient exposure dose of chest radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Sun Sook; Huh, Joon

    1995-01-01

    Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is 0.05∼0.79 mSv in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible

  10. Long term neurocognitive impact of low dose prenatal methylmercury exposure in Hong Kong.

    Science.gov (United States)

    Lam, Hugh Simon; Kwok, Ka Ming; Chan, Peggy Hiu Ying; So, Hung Kwan; Li, Albert Martin; Ng, Pak Cheung; Fok, Tai Fai

    2013-04-01

    International studies suggest that low dose prenatal methylmercury exposure (>29 nmol/L) has long-term adverse neurocognitive effects. There is evidence that the majority of children in Hong Kong exceed this level as a result of high fish consumption of mothers during pregnancy. To study whether there are any associations between low-dose prenatal methylmercury exposure and neurocognitive outcomes in Hong Kong children. All 1057 children from the original birth cohort were eligible for entry into the study, except children with conditions that would affect neurocognitive development, but were unrelated to methylmercury exposure. Subjects were assessed by a wide panel of tests covering a broad range of neurocognitive functions: Hong Kong Wechsler Intelligence Scale for Children (HK-WISC), Hong Kong List Learning Test (HKLLT), Tests of Everyday Attention for Children (TEACH), Boston Naming Test, and Grooved Pegboard Test. 608 subjects were recruited (median age 8.2 years, IQR 7.3, 8.8; 53.9% boys). After correction by confounders including child age and sex, multivariate analysis showed that cord blood mercury concentration was significantly associated with three subtests: Picture Arrangement of HK-WISC (coefficient -0.944, P=0.049) and Short and Long Delay Recall Difference of the HKLLT (coefficient -1.087, P=0.007 and coefficient -1.161, P=0.005, respectively), i.e., performance worsened with increasing prenatal methylmercury exposure in these subtests. Small, but statistically significant adverse associations between prenatal methylmercury exposure and long-term neurocognitive effects (a visual sequencing task and retention ability of verbal memory) were found in our study. These effects are compatible with findings of studies with higher prenatal methylmercury exposure levels and suggest that safe strategies to further reduce exposure levels in Hong Kong are desirable. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    International Nuclear Information System (INIS)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu

    2001-01-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52±15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m 2 or higher were assigned to the high dose group and those given doses under 300 mg/m 2 to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3±218.2 mg/m 2 . In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m 2 appeared to be the borderline dose beyond which there were

  12. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    2001-05-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52{+-}15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m{sup 2} or higher were assigned to the high dose group and those given doses under 300 mg/m{sup 2} to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3{+-}218.2 mg/m{sup 2}. In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m{sup 2} appeared to be the borderline dose beyond

  13. Dose-related gene expression changes in forebrain following acute, low-level chlorpyrifos exposure in neonatal rats

    International Nuclear Information System (INIS)

    Ray, Anamika; Liu Jing; Ayoubi, Patricia; Pope, Carey

    2010-01-01

    Chlorpyrifos (CPF) is a widely used organophosphorus insecticide (OP) and putative developmental neurotoxicant in humans. The acute toxicity of CPF is elicited by acetylcholinesterase (AChE) inhibition. We characterized dose-related (0.1, 0.5, 1 and 2 mg/kg) gene expression profiles and changes in cell signaling pathways 24 h following acute CPF exposure in 7-day-old rats. Microarray experiments indicated that approximately 9% of the 44,000 genes were differentially expressed following either one of the four CPF dosages studied (546, 505, 522, and 3,066 genes with 0.1, 0.5, 1.0 and 2.0 mg/kg CPF). Genes were grouped according to dose-related expression patterns using K-means clustering while gene networks and canonical pathways were evaluated using Ingenuity Pathway Analysis (registered) . Twenty clusters were identified and differential expression of selected genes was verified by RT-PCR. The four largest clusters (each containing from 276 to 905 genes) constituted over 50% of all differentially expressed genes and exhibited up-regulation following exposure to the highest dosage (2 mg/kg CPF). The total number of gene networks affected by CPF also rose sharply with the highest dosage of CPF (18, 16, 18 and 50 with 0.1, 0.5, 1 and 2 mg/kg CPF). Forebrain cholinesterase (ChE) activity was significantly reduced (26%) only in the highest dosage group. Based on magnitude of dose-related changes in differentially expressed genes, relative numbers of gene clusters and signaling networks affected, and forebrain ChE inhibition only at 2 mg/kg CPF, we focused subsequent analyses on this treatment group. Six canonical pathways were identified that were significantly affected by 2 mg/kg CPF (MAPK, oxidative stress, NFΚB, mitochondrial dysfunction, arylhydrocarbon receptor and adrenergic receptor signaling). Evaluation of different cellular functions of the differentially expressed genes suggested changes related to olfactory receptors, cell adhesion/migration, synapse

  14. Dose assessment from exposure to radon, thoron and their progeny concentrations in the dwellings of sub-mountainous region of Jammu and Kashmir, India

    International Nuclear Information System (INIS)

    Kaur, M.; Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, Punjab; Kumar, A.; Mehra, R.; Mishra, R.

    2018-01-01

    The present work deals with the assessment of annual inhalation dose due to exposure of indoor radon, thoron and their progeny concentrations in the villages situated in sub-mountainous region of Jammu and Kashmir, India. The distribution of the data and the homogeneity of medians among different seasons and dwellings were assessed with the Shapiro-Wilk test and the Mann-Whitney test. The estimated total annual inhalation dose in these villages varied from 0.5 to 1.9 mSv year -1 which is less than the prescribed limit by ICRP (2008). Thus, the investigated area is safe from irradiation of radon, thoron and their progeny. (author)

  15. Efficacy of a dose range of simulated sunlight exposures in raising vitamin D status in South Asian adults: implications for targeted guidance on sun exposure.

    Science.gov (United States)

    Farrar, Mark D; Webb, Ann R; Kift, Richard; Durkin, Marie T; Allan, Donald; Herbert, Annie; Berry, Jacqueline L; Rhodes, Lesley E

    2013-06-01

    Vitamin D is essential for bone health, and cutaneous synthesis is an important source. South Asians cannot attain adequate amounts of vitamin D by following general recommendations on summer sunlight exposure at northerly latitudes, and increased exposure may be appropriate for improving their vitamin D status. We examined the efficacy of a dose range of simulated summer sunlight exposures in raising vitamin D status in UK adults of South Asian ethnicity. In a dose-response study, healthy adults of South Asian ethnicity (n = 60; 20-60 y old) received 1 of 6 ultraviolet exposures ranging from 0.65 to 3.9 standard erythema doses (SEDs), which were equivalent to 15-90 min unshaded noontime summer sunlight at 53.5°N (Manchester, United Kingdom), 3 times/wk for 6 wk, while wearing casual clothes that revealed a 35% skin area. Serum 25-hydroxyvitamin D [25(OH)D] was measured weekly, and dietary vitamin D was estimated. At baseline, all completing participants (n = 51) were vitamin D insufficient [25(OH)D concentrations 10 ng/mL. Targeted guidance on sunlight exposure could usefully enhance vitamin D status to avoid deficiency [25(OH)D concentration >10 ng/mL] in South Asians living at latitudes distant from the equator. This trial was registered at the ISRCTN Register (www.isrctn.org) as 07565297.

  16. Evaluation of dose conversion coefficients for external exposure using Taiwanese reference man and woman

    International Nuclear Information System (INIS)

    Chang, S.J.; Hung, S.Y.; Liu, Y.L.; Jiang, S.H.; Wu, J.

    2015-01-01

    Reference man has been widely used for external and internal dose evaluation of radiation protection. The parameters of the mathematical model of organs suggested by the International Commission of Radiological Protection (ICRP) are adopted from the average data of Caucasians. However, the organ masses of Asians are significantly different from the data of Caucasians, leading to potentially dosimetric errors. In this study, a total of 40 volunteers whose heights and weights corresponded to the statistical average of Taiwanese adults were recruited. Magnetic resonance imaging was performed, and T2-weighted images were acquired. The Taiwanese reference man and woman were constructed according to the measured organ masses. The dose conversion coefficients (DCFs) for anterior-posterior (AP), posterior-anterior (PA), right lateral (RLAT) and left lateral (LLAT) irradiation geometries were simulated. For the Taiwanese reference man, the average differences of the DCFs compared with the results of ICRP-74 were 7.6, 5.1 and 11.1 % for 0.1, 1 and 10 MeV photons irradiated in the AP direction. The maximum difference reached 51.7 % for the testes irradiated by 10 MeV photons. The size of the trunk, the volume and the geometric position of organs can cause a significant impact on the DCFs for external exposure of radiation. The constructed Taiwanese reference man and woman can be used in radiation protection to increase the accuracy of dose evaluation for the Taiwanese population. (authors)

  17. Dose to population as a metric in the design of optimised exposure control in digital mammography

    International Nuclear Information System (INIS)

    Klausz, R.; Shramchenko, N.

    2005-01-01

    This paper describes a methods for automatic optimisation of parameter (AOP) in digital mammography systems. Using a model of the image chain, contrast to noise ratio (CNR) and average glandular dose (AGD) are computed for possible X-ray parameters and breast types. The optimisation process consists of the determination of the operating points providing the lowest possible AGD for each CNR level and breast type. The proposed metric for the dose used in the design of an AOP mode is the resulting dose to the population, computed by averaging the AGD values over the distribution of breast types in the population. This method has been applied to the automatic exposure control of new digital mammography equipment. Breast thickness and composition are estimated from a low dose pre-exposure and used to index tables containing sets of optimised operating points. The resulting average dose to the population ranges from a level comparable to state-of-the-art screen/film mammography to a reduction by a factor of two. Using this method, both CNR and dose are kept under control for all breast types, taking into consideration both individual and collective risk. (authors)

  18. Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?

    Science.gov (United States)

    Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes

    2018-05-01

    The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.

  19. External radiation dose and cancer mortality among French nuclear workers: considering potential confounding by internal radiation exposure.

    Science.gov (United States)

    Fournier, L; Laurent, O; Samson, E; Caër-Lorho, S; Laroche, P; Le Guen, B; Laurier, D; Leuraud, K

    2016-11-01

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat à l'Energie Atomique), AREVA NC, or EDF (Electricité de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  20. External radiation dose and cancer mortality among French nuclear workers. Considering potential confounding by internal radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, L.; Laurent, O.; Samson, E.; Caer-Lorho, S.; Laurier, D.; Leuraud, K. [Institute for Radiological Protection and Nuclear Safety, Fontenay aux Roses (France). Ionizing Radiation Epidemiology Lab.; Laroche, P. [AREVA, Paris (France); Le Guen, B. [EDF, Saint Denis (France)

    2016-11-15

    French nuclear workers have detailed records of their occupational exposure to external radiation that have been used to examine associations with subsequent cancer mortality. However, some workers were also exposed to internal contamination by radionuclides. This study aims to assess the potential for bias due to confounding by internal contamination of estimates of associations between external radiation exposure and cancer mortality. A cohort of 59,004 workers employed for at least 1 year between 1950 and 1994 by CEA (Commissariat a l'Energie Atomique), AREVA NC, or EDF (Electricite de France) and badge-monitored for external radiation exposure were followed through 2004 to assess vital status and cause of death. A flag based on a workstation-exposure matrix defined four levels of potential for internal contamination. Standardized mortality ratios were assessed for each level of the internal contamination indicator. Poisson regression was used to quantify associations between external radiation exposure and cancer mortality, adjusting for potential internal contamination. For solid cancer, the mortality deficit tended to decrease as the levels of potential for internal contamination increased. For solid cancer and leukemia excluding chronic lymphocytic leukemia, adjusting the dose-response analysis on the internal contamination indicator did not markedly change the excess relative risk per Sievert of external radiation dose. This study suggests that in this cohort, neglecting information on internal dosimetry while studying the association between external dose and cancer mortality does not generate a substantial bias. To investigate more specifically the health effects of internal contamination, an effort is underway to estimate organ doses due to internal contamination.

  1. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  2. Reassessment of the potential radiological doses for residents resettling Enewetak Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Mount, M.E.; Clegg, B.R.; Conrado, C.L.

    1980-01-01

    The purpose of this report is to refine the dose predictions, subsequent to the cleanup effort, for alternate living patterns proposed for resettlement of Enewetak Atoll. The most recent data developed from projects at Enewetak and Bikini Atolls for concentration and uptake of Cs, Sr, Pu, and Am were used in conjunction with recent dietary information and current dose models to predict annual dose rates and 30- and 50-y integral doses (dose commitments). The terrestrial food chain in the most significant exposure pathway - it contributes more than 50% of the total dose - and external gamma exposure is the second most significant pathway. Other pathways evaluated are the marine food chain, drinking water, and inhalation

  3. Lung toxicity determination by in vitro exposure at the air liquid interface with an integrated online dose measurement

    International Nuclear Information System (INIS)

    Muelhopt, Sonja; Paur, H-R; Diabate, S; Weiss, C; Krebs, T

    2009-01-01

    Epidemiological studies show an association between the concentration of ultrafine particles in the atmosphere and the rate of mortality or morbidity due to respiratory and cardiovascular diseases. For the quantitative assessment of the toxicity of airborne nanoparticles the dose-response relationship is tested in in vitro test systems using bioassays of cell cultures as sensor. For the air-liquid interface exposure of cell cultures towards aerosols the Karlsruhe exposure system was developed. The human lung cell cultures are exposed in VITROCELL (registered) system modules with a constant flow of the conditioned aerosol. After exposure the cells are analyzed to measure the biological responses such as viability, inflammatory or oxidative stress. For the determination of the dose response relationship the accurate knowledge of the deposited particle mass is essential. A new online method is developed in the Karlsruhe exposure system: the sensor of a quartz crystal microbalance is placed in an exposure chamber instead of the membrane insert and exposed to the aerosol in the same way as the cell cultures. The deposited mass per area unit is monitored as a function of exposure time showing a linear relationship for a constant aerosol flow with defined particle concentration. A comparison of this new dose signal to a dosimetry method using fluorescein sodium particles shows a very good correlation between the sensor signal of the quartz crystal microbalance and the deposited mass on the membranes shown by spectroscopy. This system for the first time provides an online dose measurement for in vitro experiments with nanoparticles.

  4. Perinatal exposure to low-dose BDE-47, an emergent environmental contaminant, causes hyperactivity in rat offspring.

    Science.gov (United States)

    Suvorov, Alexander; Girard, Sylvie; Lachapelle, Sophie; Abdelouahab, Nadia; Sebire, Guillaume; Takser, Larissa

    2009-01-01

    Polybrominated diphenyl ethers (PBDE) are a group of environmental contaminants increasing in North America. Few data are available on neurobehavioral effects at low-dose exposure. Our goal in the present study was to evaluate whether low-dose BDE-47, which is the most abundant PBDE in human samples, affects the neurobehavioral development of rats. Dams were exposed to vehicle or low-dose BDE-47 (0.002, 0.02 and 0.2 mg/kg body weight) each 5 days from gestational day 15 to postnatal day (PND) 20 by intravenous injections. Spontaneous locomotor activity of pups was assessed using the open field test on PND 15, 20 and 25. Sensorimotor coordination was assessed using a RotaRod on PND 30. Exposure to BDE-47 increased locomotor activity of pups. Developmental landmarks and sensorimotor coordination were not influenced by exposure to BDE-47. BDE-47 content in adipose tissue of exposed rats was similar to that known for human populations. These results indicate neurodevelopmental disruption induced in rats by BDE-47 at levels found in the human population.

  5. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Flament, O.; Fleetwood, D.M.; Leray, J.L.; Paillet, P.; Riewe, L.C.; Winokur, P.S.

    1999-01-01

    Deep and shallow electron traps form in irradiated thermal SiO 2 as a natural response to hole transport and trapping. The density and stability of these defects are discussed, as are their implications for total-dose modeling

  6. Effect of extended exposure to low-dose radiation on autoimmune diseases of immunologically suppressed MRL/MpTn-gld/gld mice

    International Nuclear Information System (INIS)

    Ootsuyama, Akira; Okazaki, Ryuji; Norimura, Toshiyuki

    2003-01-01

    The purpose of this paper is to analyze the relationship between alterations of splenic T-cell subpopulations and the amelioration of autoimmune diseases of MRL/MpTn-gld/gld mice (MRL/gld mice) after extended exposure to low-dose radiation. After the onset of disease, 4-month-old MRL/gld mice were exposed to doses of 0.05, 0.2, and 0.5 Gy/day for 4 weeks (5 days/week), for total doses of 1, 4, and 10 Gy, respectively. The MRL/gld mice that were irradiated with 0.2 and 0.5 Gy/day showed an obvious decrease in the proportion of splenic CD4 - CD8 - T cells and remission of their autoimmune diseases. After the last irradiation, apoptotic cells were found in the white pulp of the spleen of the MRL/gld mice irradiated with 0.2 Gy/day, but not in the MRL/MpJ-+/+ mice (MRL/wild mice), which experienced a similar treatment. Before the onset of disease, 3-month-old MRL/gld mice subjected to 0.2 Gy/day showed a decrease in the proportion of splenic CD4 - CD8 - T cells and less remission of their autoimmune diseases than the 4-month-old mice. These results suggest that the accumulated CD4 - CD8 - T cells are more sensitive to radiation than other T cell subpopulations, and that decreasing CD4 - CD8 - T cells with extended exposure to low-dose radiation leads to the amelioration of autoimmune disease. (author)

  7. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Flament, O.; Paillet, P.; Leray, J.L.

    1999-01-01

    Radiation-induced hole and electron transport and trapping are fundamental to MOS total-dose models. Here we separate the effects of electron-hole annihilation and electron trapping on the neutralization of radiation-induced charge during switched-bias irradiation for hard and soft oxides, via combined thermally stimulated current (TSC) and capacitance-voltage measurements. We also show that present total-dose models cannot account for the thermal stability of deeply trapped electrons near the Si/SiO 2 interface, or the inability of electrons in deep or shallow traps to contribute to TSC at positive bias following (1) room-temperature, (2) high-temperature, or (3) switched-bias irradiation. These results require revisions of modeling parameters and boundary conditions for hole and electron transport in SiO 2 . The nature of deep and shallow electron traps in the near-interfacial SiO 2 is discussed

  8. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure

    Science.gov (United States)

    Johnston, Sara C.; Lin, Kenny L.; Twenhafel, Nancy A.; Raymond, Jo Lynne W.; Shamblin, Joshua D.; Wollen, Suzanne E.; Wlazlowski, Carly B.; Wilkinson, Eric R.; Botto, Miriam A.; Goff, Arthur J.

    2015-01-01

    Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies. PMID:26413900

  9. Dose Response of MARV/Angola Infection in Cynomolgus Macaques following IM or Aerosol Exposure.

    Directory of Open Access Journals (Sweden)

    Sara C Johnston

    Full Text Available Marburg virus infection in humans causes a hemorrhagic disease with a high case fatality rate. Countermeasure development requires the use of well-characterized animal models that mimic human disease. To further characterize the cynomolgus macaque model of MARV/Angola, two independent dose response studies were performed using the intramuscular or aerosol routes of exposure. All animals succumbed at the lowest target dose; therefore, a dose effect could not be determined. For intramuscular-exposed animals, 100 PFU was the first target dose that was not significantly different than higher target doses in terms of time to disposition, clinical pathology, and histopathology. Although a significant difference was not observed between aerosol-exposed animals in the 10 PFU and 100 PFU target dose groups, 100 PFU was determined to be the lowest target dose that could be consistently obtained and accurately titrated in aerosol studies.

  10. Radiation doses to patients in computed tomography including a ready reckoner for dose estimation

    International Nuclear Information System (INIS)

    Szendroe, G.; Axelsson, B.; Leitz, W.

    1995-11-01

    The radiation burden from CT-examinations is still growing in most countries and has reached a considerable part of the total from medical diagnostic x-ray procedures. Efforts for avoiding excess radiation doses are therefore especially well motivated within this field. A survey of CT-examination techniques practised in Sweden showed that standard settings for the exposure variables are used for the vast majority of examinations. Virtually no adjustments to the patient's differences in anatomy have been performed - even for infants and children on average the same settings have been used. The adjustment of the exposure variables to the individual anatomy offers a large potential of dose savings. Amongst the imaging parameters, a change of the radiation dose will primarily influence the noise. As a starting point it is assumed that, irrespective of the patient's anatomy, the same level of noise can be accepted for a certain diagnostic task. To a large extent the noise level is determined by the number of photons that are registered in the detector. Hence, for different patient size and anatomy, the exposure should be adjusted so that the same transmitted photon fluence is achieved. An appendix with a ready reckoner for dose estimation for CT-scanners used in Sweden is attached. 7 refs, 5 figs, 8 tabs

  11. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  12. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  13. Age-dependent exposure to radioactive iodine (131I) in the thyroid and total body of newborn, pubertal and adult fischer 344 rats

    International Nuclear Information System (INIS)

    Nitta, Yumiko; Fujimoto, Nariaki; Kamiya, Kenji; Hoshi, Masaharu; Endo, Satoru

    2001-01-01

    Female rats of the Fischer 344 strain at ages of 1, 4 and 9 weeks were exposed to 131 I intraperitoneally with activities of 0.38, 1.03 and 3.42 kBq per gram of body weight under the condition of iodine deficiency. The absorbed doses in the thyroid increased linearly depending on the injected activities. Irradiation at 1 week old caused heavier exposure than those at 4 and 9 weeks old by 7.5 and 7.7 times, respectively; however, damage of the thyroid tissue was more obvious in the 4-week-old groups than in the 1-week-old groups. The absorbed doses in the total body were proportional to the square root of the injected activities. The one-week-old groups were exposed more heavily than the 4- and 9-week-old groups by 3.6 and 4.7 times, respectively, shown by the slow excretion of 131 I with the values of effective half-life of 131 I activity (T eff ). An IDD-treatment was not so effective to enhance the 131 I absorption in the total body, as in the thyroid. No matter how the iodine concentration in the blood changed, the 1-week-old groups could not react to normalize the level. We drew standard curves, which enabled us to estimate the absorbed doses in the thyroid and the total body in the case of the injected activities of 131 I for the newborn, pubertal and adult rats. (author)

  14. A first-principles approach to total-dose hardness assurance

    International Nuclear Information System (INIS)

    Fleetwood, D.M.

    1995-01-01

    A first-principles approach to radiation hardness assurance was described that provides the technical background to the present US and European total-dose radiation hardness assurance test methods for MOS technologies, TM 1019.4 and BS 22900. These test methods could not have been developed otherwise, as their existence depends not on a wealth of empirical comparisons of IC data from ground and space testing, but on a fundamental understanding of MOS defect growth and annealing processes. Rebound testing should become less of a problem for advanced MOS small-signal electronics technologies for systems with total dose requirements below 50--100 krad(SiO 2 ) because of trends toward much thinner gate oxides. For older technologies with thicker gate oxides and for power devices, rebound testing is unavoidable without detailed characterization studies to assess the impact of interface traps on devices response in space. The QML approach is promising for future hardened technologies. A sufficient understanding of process effects on radiation hardness has been developed that should be able to reduce testing costs in the future for hardened parts. Finally, it is hoped that the above discussions have demonstrated that the foundation for cost-effective hardness assurance tests is laid with studies of the basic mechanisms of radiation effects. Without a diligent assessment of new radiation effects mechanisms in future technologies, one cannot be assured that the present generation of radiation test standards will continue to apply

  15. SOILD: A computer model for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil

    International Nuclear Information System (INIS)

    Chen, S.Y.; LePoire, D.; Yu, C.; Schafetz, S.; Mehta, P.

    1991-01-01

    The SOLID computer model was developed for calculating the effective dose equivalent from external exposure to distributed gamma sources in soil. It is designed to assess external doses under various exposure scenarios that may be encountered in environmental restoration programs. The models four major functional features address (1) dose versus source depth in soil, (2) shielding of clean cover soil, (3) area of contamination, and (4) nonuniform distribution of sources. The model is also capable of adjusting doses when there are variations in soil densities for both source and cover soils. The model is supported by a data base of approximately 500 radionuclides. 4 refs

  16. Evaluation of exposure to ionizing radiation among gamma camera operators

    Directory of Open Access Journals (Sweden)

    Agnieszka Anna Domańska

    2013-08-01

    Full Text Available Background: Protection of nuclear medicine unit employees from hazards of the ionizing radiation is a crucial issue of radiation protection services. We aimed to assess the severity of the occupational radiation exposure of technicians performing scintigraphic examinations at the Nuclear Medicine Department, Central Teaching Hospital of Medical University in Łódź, where thousands of different diagnostic procedures are performed yearly. Materials and Methods: In 2013 the studied diagnostic unit has employed 10 technicians, whose exposure is permanently monitored by individual dosimetry. We analyzed retrospective data of quarterly doses in terms of Hp(10 dose equivalents over the years 2001-2010. Also annual and five-year doses were determined to relate the results to current regulations. Moreover, for a selected period of one year, we collected data on the total activity of radiopharmaceuticals used for diagnostics, to analyze potential relationship with doses recorded in technicians performing the examinations. Results: In a 10-year period under study, the highest annual dose recorded in a technician was 2 mSv, which represented 10% of the annual dose limit of 20 mSv. The highest total dose for a 5-year period was 7.1 mSv, less than 10% of a 5-year dose limit for occupational exposure. Positive linear correlation was observed between total activity of radiopharmaceuticals used for diagnostics in the period of three months and respective quarterly doses received by technicians performing examinations. Conclusions: Doses received by nuclear medicine technicians performing diagnostic procedures in compliance with principles of radiation protection are low, which is confirmed by recognizing the technicians of this unit as B category employees. Med Pr 2013;64(4:503–506

  17. Dose-rate models for human survival after exposure to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Jones, T.D.; Morris, M.D.; Young, R.W.

    1986-01-01

    This paper reviews new estimates of the L/sub 50/ in man by Mole and by Rotblat, the biological processes contributing to hematologic death, the collection of animal experiments dealing with hematologic death, and the use of regression analysis to make new estimates of human mortality based on all relevant animal studies. Regression analysis of animal mortality data has shown that mortality is dependent strongly on dose rate, species, body weight, and time interval over which the exposure is delivered. The model has predicted human LD/sub 50/s of 194, 250, 310, and 360 rad to marrow when the exposure time is a minute, an hour, a day, and a week, respectively.

  18. Exposure doses of nurses in the radiation therapy using sealed small radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Hatori, N; Yamakawa, K; Eda, T; Habu, T; Endo, H [Gunma Cancer Center Hospital (Japan)

    1979-11-01

    In radiation for malignant tumor, interstitial irradiation and/or intracavitary irradiations are performed in addition to external irradiation. The former two treatments are well applied for the tumors at head and neck region, especially carcinoma of the tongue and for that in gynecological tumor like carcinoma of the cervix. However, nurses are supposed to be irradiated during the treatment, as they help the handling of radiation sourses to insert or to pierce them directly into diseased parts. In this paper, we measured the relationship between working time of nurses for the treatment and exposure doses of nurses, using a thermoluminescence dosimeter, the exposure doses were approximately proportional to the working time, and 3-6 mR working time for a treatment in the cases of the diseases head and neck, and 4 mR working time for a treatment in the cases of gynecological diseases.

  19. Exposure doses of nurses in the radiation therapy using sealed small radiation sources

    International Nuclear Information System (INIS)

    Hatori, Noboru; Yamakawa, Katsumi; Eda, Tetsuo; Habu, Takashi; Endo, Hiroshi

    1979-01-01

    In radiation for malignant tumor, interstitial irradiation and/or intracavitary irradiations are performed in addition to external irradiation. The former two treatments are well applied for the tumors at head and neck region, especially carcinoma of the tongue and for that in gynecological tumor like carcinoma of the cervix. However, nurses are supposed to be irradiated during the treatment, as they help the handling of radiation sourses to insert or to pierce them directly into diseased parts. In this paper, we measured the relationship between working time of nurses for the treatment and exposure doses of nurses, using a thermoluminescence dosimeter, the exposure doses were approximately proportional to the working time, and 3-6 mR working time for a treatment in the cases of the diseases head and neck, and 4 mR working time for a treatment in the cases of gynecological diseases. (author)

  20. Prostate enlargement in mice due to fetal exposure to low doses of estradiol or diethylstilbestrol and opposite effects at high doses

    Science.gov (United States)

    Saal, Frederick S. vom; Timms, Barry G.; Montano, Monica M.; Palanza, Paola; Thayer, Kristina A.; Nagel, Susan C.; Dhar, Minati D.; Ganjam, V. K.; Parmigiani, Stefano; Welshons, Wade V.

    1997-01-01

    On the basis of results of studies using high doses of estrogens, exposure to estrogen during fetal life is known to inhibit prostate development. However, it is recognized in endocrinology that low concentrations of a hormone can stimulate a tissue, while high concentrations can have the opposite effect. We report here that a 50% increase in free-serum estradiol in male mouse fetuses (released by a maternal Silastic estradiol implant) induced a 40% increase in the number of developing prostatic glands during fetal life; subsequently, in adulthood, the number of prostatic androgen receptors per cell was permanently increased by 2-fold, and the prostate was enlarged by 30% (due to hyperplasia) relative to untreated males. However, as the free serum estradiol concentration in male fetuses was increased from 2- to 8-fold, adult prostate weight decreased relative to males exposed to the 50% increase in estradiol. As a model for fetal exposure to man-made estrogens, pregnant mice were fed diethylstilbestrol (DES) from gestation days 11 to 17. Relative to controls, DES doses of 0.02, 0.2, and 2.0 ng per g of body weight per day increased adult prostate weight, whereas a 200-ng-per-g dose decreased adult prostate weight in male offspring. Our findings suggest that a small increase in estrogen may modulate the action of androgen in regulating prostate differentiation, resulting in a permanent increase in prostatic androgen receptors and prostate size. For both estradiol and DES, prostate weight first increased then decreased with dose, resulting in an inverted-U dose-response relationship. PMID:9050904

  1. Total dose hardness of a commercial SiGe BiCMOS technology

    International Nuclear Information System (INIS)

    Van Vonno, N.; Lucas, R.; Thornberry, D.

    1999-01-01

    Over the past decade SiGe HBT technology has progress from the laboratory to actual commercial applications. When integrated into a BiMOS process, this technology has applications in low-cost space systems. In this paper, we report results of total dose testing of a SiGe/CMOS process accessible through a commercial foundry. (authors)

  2. Minor sources of miner exposure

    International Nuclear Information System (INIS)

    Strong, J.C.; Green, N.; Brown, K.; O'Riordan, M.C.

    1983-01-01

    The sources of radiation exposure to miners in non-coal mines in addition to radon daughters are thoron daughters in mine air, long-lived radionuclides in mine dust and gamma radiation from the local rocks. A crude estimate of the total annual effective dose equivalent from these minor sources is 2 - 5 mSv which is of secondary importance compared to the dose from radon daughters. (UK)

  3. Variability of dose predictions for cesium-137 and radium-226 using the PRISM method

    International Nuclear Information System (INIS)

    Bergstroem, U.; Andersson, K.; Roejder, B.

    1984-01-01

    The uncertainty associated with dose predictions for cesium-137 and radium-226 in a specific ecosystem has been studied. The method used is a systematic method for determining the effect of parameter uncertainties on model prediction called PRISM. The ecosystems studied are different types of lakes where the following transport processes are included: runoff of water in the lake, irrigation, transport in soil, in groundwater and in sediment. The ecosystems are modelled by the compartment principle, using the BIOPATH-code. Seven different internal exposure pathways are included. The total dose commitment for both nuclides varies about two orders of magnitude. For cesium-137 the total dose and the uncertainty are dominated by the consumption of fish. The most important factor to the total uncertainty is the concentration factor water-fish. For radium-226 the largest contributions to the total dose are the exposure pathways, fish, milk and drinking-water. Half of the uncertainty lies in the milk dose. This uncertainty is dominated by the distribution factor for milk. (orig.)

  4. Combined methodology for estimating dose rates and health effects from exposure to radioactive pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Dunning, D.E. Jr.; Leggett, R.W.; Yalcintas, M.G.

    1980-12-01

    The work described in the report is basically a synthesis of two previously existing computer codes: INREM II, developed at the Oak Ridge National Laboratory (ORNL); and CAIRD, developed by the Environmental Protection Agency (EPA). The INREM II code uses contemporary dosimetric methods to estimate doses to specified reference organs due to inhalation or ingestion of a radionuclide. The CAIRD code employs actuarial life tables to account for competing risks in estimating numbers of health effects resulting from exposure of a cohort to some incremental risk. The combined computer code, referred to as RADRISK, estimates numbers of health effects in a hypothetical cohort of 100,000 persons due to continuous lifetime inhalation or ingestion of a radionuclide. Also briefly discussed in this report is a method of estimating numbers of health effects in a hypothetical cohort due to continuous lifetime exposure to external radiation. This method employs the CAIRD methodology together with dose conversion factors generated by the computer code DOSFACTER, developed at ORNL; these dose conversion factors are used to estimate dose rates to persons due to radionuclides in the air or on the ground surface. The combination of the life table and dosimetric guidelines for the release of radioactive pollutants to the atmosphere, as required by the Clean Air Act Amendments of 1977.

  5. Simulation of Shielding Effects on the Total Dose Observed in TDE of KISAT-1

    Directory of Open Access Journals (Sweden)

    Sung-Joon Kim

    2001-06-01

    Full Text Available The threshold voltage shift observed in TDE (Total Dose Experiment on board the KITSAT-1 is converted into dose (rad(SiO2 usinsg the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute. Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  6. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    Science.gov (United States)

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  7. Near-term and late biological effects of acute and low-dose-rate continuous gamma-ray exposure in dogs and monkeys

    International Nuclear Information System (INIS)

    Spalding, J.F.; Holland, L.M.

    1979-07-01

    Monkeys (Macaca mulatta) and dogs (beagle) were given thirteen 100-rad gamma-ray doses at 28-day intervals. The comparative response (inury and recovery) of the hematopoietic system of the two species was observed at 7-day intervals during the exposure regime. At 84 days after the thirteenth gamma-ray dose, the 1300-rad conditioned and control dogs and monkeys were challenged continuously with gamma rays at 35 r/day until death to determine the amount of radiation-induced injry remaining in conditioned animals as a reduction in mean survival time. Dogs (50%) and monkeys (8%) died from injury incurred during conditioning exposures. Thus, the comparative response (in terms of lethality) of dogs and monkeys to dose protraction by acute dose fractionation was similar to what we would expect from a single acute dose. The mean survival times for nonconditioned dogs and monkeys during continuous exposure at 35 R/day were the same (approx. 1400 h). Thus, the hematopoietic response of the two species by this method of dose protraction was not significantly different. Mean survival times of conditioned dogs and monkeys during the continuous 35-R/day gamma-ray challenge exposure were greater (significant in dogs but not in monkeys) than for their control counterparts. Thus, long-term radiation-induced injury was not measurable by this method. Conditioning doses of more than 4 times the acute LD 50 30 in dogs and approximately 2 times that in monkeys served only to increase both mean survival time and variance in a gamma-ray stress environment with a dose rate of 35 Rat/day

  8. Measurement of exposure dose and its reduction design for nurses in charge in FDG-PET/CT with contrast reviewing the manual and staff flow line

    International Nuclear Information System (INIS)

    Kashiwazaki, Rie; Tochigi, Shigeko; Onuki, Michiko; Suzuki, Kazufumi; Sakamoto, Setsu

    2013-01-01

    Nurses in charge received additional radiation exposure from the patients with intravenous FDG injection when FDG-PET/CT with contrast media was performed. The exposure dose was measured about 1.5μSv per examination on average. There was not a large difference among those when the mean exposure dose of each nurse was compared. There was a tendency that the exposure dose was less, as work years of the nurses in charge of PET/CT with contrast were longer. Consideration of radioactivity distribution in the PET/CT examination room has a potential to reduce radiation exposure dose of the nurses in charge. (author)

  9. Occupational external radiation exposure in the GDR in 1976

    International Nuclear Information System (INIS)

    Rothe, W.

    1980-01-01

    In 1976 a total of 36,794 occupationally exposed persons were monitored by the National Board of Nuclear Safety and Radiation Protection, using film badges. The monthly over-exposures (more than 4 mGy) totalled 415. In 11 cases the monthly exposure exceeded 30 mGy and 6 annual exposure values were in the range of 50 to 120 mGy. An attempt has been made to assess the annual collective and annual per caput doses for the exposed population as a whole and some subgroups without completely summing up the individual exposure data. (author)

  10. Issues in environmental control data used in DD ampersand ER worker dose exposures

    International Nuclear Information System (INIS)

    White, M.G.

    1995-01-01

    Sites for decontamination and decommissioning (DD) or environmental remediation (ER) are often from US DOE operations that began during and shortly after World War II. This paper discusses selected problems in the use of environmental data for DD and ER worker dose exposure calculations

  11. Dose response association of pregnancy cigarette smoke exposure, childhood stature, overweight and obesity

    NARCIS (Netherlands)

    Koshy, Gibby; Delpisheh, Ali; Brabin, Bernard J.

    2011-01-01

    The combined dose response effects of pregnancy cigarette smoke exposure on childhood overweight, obesity and short stature have not been reported. A community based cross-sectional survey of 3038 children aged 5-11 years from 15 primary schools in Merseyside, UK. Self-completed parental

  12. Contribution of various of manufacturing of food products to internal exposure dose of population

    International Nuclear Information System (INIS)

    Bajrashevskaya, D.A.; Goncharova, N.V.

    2007-01-01

    Since 1986, considerable data have been produced and published on all the above aspects of the Cs 137 from soils to agricultural products. Today no critical evaluation of the available information has been undertaken. There is an obvious need to evaluate the relative importance of agricultural foodstuffs as a source of internal dose. The importance of food from different production systems to the internal dose from radiocaesium was investigated in selected study sites in Belarus. This work considers approaches and methods of internal exposure dose evaluation for citizens of radioactive contaminated territories consuming food products of radioactive contaminated forests. (authors)

  13. Radiation doses for Marshall Islands Atolls Affected by U.S. Nuclear Testing:All Exposure Pathways, Remedial Measures, and Environmental Loss of 137Cs

    Energy Technology Data Exchange (ETDEWEB)

    Robison, W L; Hamilton, T F

    2009-04-20

    Rongelap Atoll (Robison et al., 1994; Simon et al., 1997), and Utrok Island at Utrok Atoll (Robison, et al., 1999) indicate that about 95-99% of the total estimated dose to people who may return to live at the atolls today (Utrok Island is populated) is the result of exposure to {sup 137}Cs. External gamma exposure from {sup 137}Cs in the soil accounts for about 10 to 15% of the total dose and {sup 137}Cs ingested during consumption of local food crops such as drinking coconut meat and fluid (Cocos nucifera L.), copra meat and milk, Pandanus fruit, and breadfruit accounts for about 85 to 90%. The other 1 to 2% of the estimated dose is from {sup 90}Sr, {sup 239+240}Pu, and {sup 241}Am. The {sup 90}Sr exposure is primarily through the food chain while the exposure to {sup 239+240}Pu, and {sup 241}Am is primarily via the inhalation pathway as a result of breathing re-suspended soil particles.

  14. Dose-area product measurement for patients in diagnostic radiography

    International Nuclear Information System (INIS)

    Alkhawad, Safaa Ibrahim Awad Elkarim

    2001-09-01

    There is a wide spread of the utilization of medical diagnostic x-ray in Sudan upon the last years, in private clinics as well as in public hospitals. The aim of this study was to measure the doses to patients from x-ray in radiography departments in Khartoum State. Use was made of ionization chamber that measures the product of dose times the exposed area of the patient in units of Gy cm 2 . The work was performed in 7 hospitals over 250 patients. 71.2% of the patients were males and 28.8% females. From this work, it appears that the chest radiography represent 42% of the total exposure of human body organs to radiography, there was also a clear variation in doses resulting from this exposure for different x-ray machines. The results of this study were compared with similar from Germany, Finland, New Zealand and Norway; which are recently available studies. The comparison showed those investigation of abdomen, spine and pelvis result in higher radiation doses. No data for limb exposure were obtained from these countries, in Sudan exposure of the limb carry radiation doses compared to the rest of the human body.(Author)

  15. Assessment of genetically significant doses to the Sofia population from natural gamma background

    International Nuclear Information System (INIS)

    Vasilev, G.; Khristova, M.

    1977-01-01

    Genetically significant dose to the population of Sofia city was assessed within a program covering larger urban communities in the country. Measurements were made of gamma background exposure rates in the gonadal region. Gonad doses were estimated using a screening factor of 0.73. Based on statistical data for total number of inhabitants and number of people of reproductive age, and on the mean annual gonad doses derived, calculations were made of genetically significant dose to the Sofia population. Base-line data were thus provided for an assessment of extra radiation dose resulting from occupational radiation exposure. (author)

  16. Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; LaBel, K. A.

    2016-01-01

    Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the radiation design margin concept with one of failure probability during a mission.

  17. Eating habits and internal radiation exposures in Japanese

    International Nuclear Information System (INIS)

    Shiraishi, Kunio

    1995-01-01

    Recently, annual dose equivalent for Japanese was estimated to be 3.75 mSv. Medical radiation exposures (2.25 mSv/y) and exposures from natural sources of radiation (1.48 mSv/y) were the major contributors to this dose. Dietary intakes of both natural and man-made radionuclides directly related to internal exposures. In this paper, internal doses received only through ingestion of radionuclides in food are described; internal doses through inhalation have been excluded. First, the representative intakes of radionuclides for Japanese were estimated from the literature. Second, the annual dose equivalents were calculated according to intakes of individual radionuclides and weighted committed dose equivalents (Sv/Bq) of the International Commission on Radiological Protection Pub. 30. Total annual doses through radiation of natural sources and man-made sources, were estimated as 0.35 mSv and 0.001 mSv, respectively. Furthermore, the effects of imported foods on internal dose in Japanese were calculated preliminarily, because the contribution of imported foods to Japanese eating habits is increasing annually and will not be negligible when assessing internal dose in the near future. (author)

  18. Drinking water as a proportion of total human exposure to volatile N-nitrosamines.

    Science.gov (United States)

    Hrudey, Steve E; Bull, Richard J; Cotruvo, Joseph A; Paoli, Greg; Wilson, Margaret

    2013-12-01

    Some volatile N-nitrosamines, primarily N-nitrosodimethylamine (NDMA), are recognized as products of drinking water treatment at ng/L levels and as known carcinogens. The U.S. EPA has identified the N-nitrosamines as contaminants being considered for regulation as a group under the Safe Drinking Water Act. Nitrosamines are common dietary components, and a major database (over 18,000 drinking water samples) has recently been created under the Unregulated Contaminant Monitoring Rule. A Monte Carlo modeling analysis in 2007 found that drinking water contributed less than 2.8% of ingested NDMA and less than 0.02% of total NDMA exposure when estimated endogenous formation was considered. Our analysis, based upon human blood concentrations, indicates that endogenous NDMA production is larger than expected. The blood-based estimates are within the range that would be calculated from estimates based on daily urinary NDMA excretion and an estimate based on methylated guanine in DNA of lymphocytes from human volunteers. Our analysis of ingested NDMA from food and water based on Monte Carlo modeling with more complete data input shows that drinking water contributes a mean proportion of the lifetime average daily NDMA dose ranging from between 0.0002% and 0.001% for surface water systems using free chlorine or between 0.001% and 0.01% for surface water systems using chloramines. The proportions of average daily dose are higher for infants (zero to six months) than other age cohorts, with the highest mean up to 0.09% (upper 95th percentile of 0.3%). © 2013 Society for Risk Analysis.

  19. Age and Chronicity of Administration Dramatically Influenced the Impact of Low Dose Paraquat Exposure on Behavior and Hypothalamic-Pituitary-Adrenal Activity

    Directory of Open Access Journals (Sweden)

    Chris A. Rudyk

    2017-07-01

    Full Text Available Little is known of the age-dependent and long-term consequences of low exposure levels of the herbicide and dopaminergic toxicant, paraquat. Thus, we assessed the dose-dependent effects of paraquat using a typical short-term (3 week exposure procedure, followed by an assessment of the effects of chronic (16 weeks exposure to a very low dose (1/10th of what previously induced dopaminergic neuronal damage. Short term paraquat treatment dose-dependently induced deficits in locomotion, sucrose preference and Y-maze performance. Chronic low dose paraquat treatment had a very different pattern of effects that were also dependent upon the age of the animal: in direct contrast to the short-term effects, chronic low dose paraquat increased sucrose consumption and reduced forced swim test (FST immobility. Yet these effects were age-dependent, only emerging in mice older than 13 months. Likewise, Y-maze spontaneous alternations and home cage activity were dramatically altered as a function of age and paraquat chronicity. In both the short and long-term exposure studies, increased corticosterone and altered hippocampal glucocorticoid receptor (GR levels were induced by paraquat, but surprisingly these effects were blunted in the older mice. Thus, paraquat clearly acts as a systemic stressor in terms of corticoid signaling and behavioral outcomes, but that paradoxical effects may occur with: (a repeated exposure at; (b very low doses; and (c older age. Collectively, these data raise the possibility that repeated “hits” with low doses of paraquat in combination with aging processes might have promoted compensatory outcomes.

  20. Relationship between medical exposure and acquisition conditions during X-ray diagnosis of small children to reduce exposure doses in Aomori Prefecture. An analysis questionnaire

    International Nuclear Information System (INIS)

    Kon, Masanori; Fukushi, Shouji; Oota, Fumio; Kawamura, Kouji; Shinohe, Tetsuo; Suwa, Kouki; Fujii, Kiyosuke; Yamagami, Hirofumi

    2000-01-01

    A questionnaire survey to determine the exposure dose of each site imaged was performed by the Aomori Association of Radiological Technologists in September 1998. Based on the results, the relation between the entrance surface dose and loading factor and film/screen system during chest and hip joint imaging of children was analyzed, and reduction of the exposure dose was assessed. The entrance surface dose was calculated by a non-dosimeter dosimetry (NDD) method. A slight correlation was observed between tube voltage and the product of tube current x imaging time for chest imaging, but not for hip joint imaging. No correlation was observed between the entrance surface dose and tube current x imaging time for chest imaging, but a positive correlation was observed for hip joint imaging. The rates at which an inverter device, a three-phase device, and a single-phase device were used as the high-voltage generator for chest imaging were 57.5%, 30.0%, 12.5%, respectively, and 57.0%, 26.0%, and 17.0%, respectively, for hip joint imaging. The tube voltage ranged from 45 to 130 kV (mean: 70-80 kV) for chest imaging, and from 45 to 74 kV (mean: 60 kV) for hip joint imaging. The tube current ranged from 100 to 800 mA (mean: 300 mA) for chest imaging, and from 50 to 650 mA (mean: 200 mA) for hip joint imaging. The mean entrance surface dose for chest imaging was smaller (1/3-1/5) than for hip joint imaging. The maximal difference in entrance surface dose between facilities was 39.0 times, the minimal difference was 18.4 times, and the difference was less than half of the difference in adults. The rates at which photosensitive materials were used was 8% blue luminescence 8%, green luminescence 76%. Many facilities used photosensitive materials whose the relative sensitivity was approximately 250. It was concluded that reduction of the exposure doses during imaging of children had been thoroughly considered at each facility. Dose reduction was concluded to be possible by using