WorldWideScience

Sample records for total dose results

  1. Theoretic simulation for CMOS device on total dose radiation response

    International Nuclear Information System (INIS)

    He Baoping; Zhou Heqin; Guo Hongxia; He Chaohui; Zhou Hui; Luo Yinhong; Zhang Fengqi

    2006-01-01

    Total dose effect is simulated for C4007B, CC4007RH and CC4011 devices at different absorbed dose rate by using linear system theory. When irradiation response and dose are linear, total dose radiation and post-irradiation annealing at room temperature are determined for one random by choosing absorbed dose rate, and total dose effect at other absorbed dose rate can be predicted by using linear system theory. The simulating results agree with the experimental results at different absorbed dose rate. (authors)

  2. Recent Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.

    2005-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T

  3. Dependence of total dose response of bipolar linear microcircuits on applied dose rate

    International Nuclear Information System (INIS)

    McClure, S.; Will, W.; Perry, G.; Pease, R.L.

    1994-01-01

    The effect of dose rate on the total dose radiation hardness of three commercial bipolar linear microcircuits is investigated. Total dose tests of linear bipolar microcircuits show larger degradation at 0.167 rad/s than at 90 rad/s even after the high dose rate test is followed by a room temperature plus a 100 C anneal. No systematic correlation could be found for degradation at low dose rate versus high dose rate and anneal. Comparison of the low dose rate with the high dose rate anneal data indicates that MIL-STD-883, method 1019.4 is not a worst-case test method when applied to bipolar microcircuits for low dose rate space applications

  4. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA GSFC and NEPP

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Label, Kenneth A.; Cochran, Donna J.; O'Bryan, Martha V.

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include opto-electronics, digital, analog, linear bipolar devices, and hybrid devices.

  5. Pulsed total dose damage effect experimental study on EPROM

    International Nuclear Information System (INIS)

    Luo Yinhong; Yao Zhibin; Zhang Fengqi; Guo Hongxia; Zhang Keying; Wang Yuanming; He Baoping

    2011-01-01

    Nowadays, memory radiation effect study mainly focus on functionality measurement. Measurable parameters is few in china. According to the present situation, threshold voltage testing method was presented on floating gate EPROM memory. Experimental study of pulsed total dose effect on EPROM threshold voltage was carried out. Damage mechanism was analysed The experiment results showed that memory cell threshold voltage negative shift was caused by pulsed total dose, memory cell threshold voltage shift is basically coincident under steady bias supply and no bias supply. (authors)

  6. New Insights into Fully-Depleted SOI Transistor Response During Total Dose Irradiation

    International Nuclear Information System (INIS)

    Burns, J.A.; Dodd, P.E.; Keast, C.L.; Schwank, J.R.; Shaneyfelt, M.R.; Wyatt, P.W.

    1999-01-01

    Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. No evidence was found for total-dose induced snap back. These results have implications for hardness assurance testing

  7. Evaluation of accelerated test parameters for CMOS IC total dose hardness prediction

    International Nuclear Information System (INIS)

    Sogoyan, A.V.; Nikiforov, A.Y.; Chumakov, A.I.

    1999-01-01

    The approach to accelerated test parameters evaluation is presented in order to predict CMOS IC total dose behavior in variable dose-rate environment. The technique is based on the analytical model of MOSFET parameters total dose degradation. The simple way to estimate model parameter is proposed using IC's input-output MOSFET radiation test results. (authors)

  8. Correct statistical evaluation for total dose in rural settlement

    International Nuclear Information System (INIS)

    Vlasova, N.G.; Skryabin, A.M.

    2001-01-01

    Statistical evaluation of dose reduced to the determination of an average value and its error. If an average value of a total dose in general can be determined by simple summarizing of the averages of its external and internal components, the evaluation of an error can be received only from its distribution. Herewith, considering that both components of the dose are interdependent, to summarize their distributions, as a last ones of a random independent variables, is incorrect. It follows that an evaluation of the parameters of the total dose distribution, including an error, in general, cannot be received empirically, particularly, at the lack or absence of the data on one of the components of the last one, that constantly is happens in practice. If the evaluation of an average for total dose was defined somehow, as the best, as an average of a distribution of the values of individual total doses, as summarizing the individual external and internal doses by the random type, that an error of evaluation had not been produced. The methodical approach to evaluation of the total dose distribution at the lack of dosimetric information was designed. The essence of it is original way of an interpolation of an external dose distribution, using data on an internal dose

  9. Results of Hematopoietic Stem Cell Transplantation After Treatment With Different High-Dose Total-Body Irradiation Regimens in Five Dutch Centers

    International Nuclear Information System (INIS)

    Loes van Kempen-Harteveld, M.; Brand, Ronald; Kal, Henk B.; Verdonck, Leo F.; Hofman, Pieter; Schattenberg, Anton V.; Maazen, Richard W. van der; Cornelissen, Jan J.; Eijkenboom, Wil M.H.; Lelie, Johannes P. van der; Oldenburger, Foppe; Barge, Renee M.; Biezen, Anja van; Vossen, Jaak M.J.J.; Noordijk, Evert M.; Struikmans, Henk

    2008-01-01

    Purpose: To evaluate results of high-dose total-body irradiation (TBI) regimens for hematopoietic stem cell transplantation. Methods and Materials: A total of 1,032 patients underwent TBI in one or two fractions before autologous or allogeneic hematologic stem cell transplantation for acute leukemia and non-Hodgkin's lymphoma. The TBI regimens were normalized by using the biological effective dose (BED) concept. The BED values were divided into three dose groups. Study end points were relapse incidence (RI), non-relapse mortality (NRM), relapse-free survival (RFS), and overall survival (OS). Multivariate analysis was performed, stratified by disease. Results: In the highest TBI dose group, RI was significantly lower and NRM was higher vs. the lower dose groups. However, a significant influence on RFS and OS was not found. Relapses in the eye region were found only after shielding to very low doses. Age was of significant influence on OS, RFS, and NRM in favor of younger patients. The NRM of patients older than 40 years significantly increased, and OS decreased. There was no influence of age on RI. Men had better OS and RFS and lower NRM. Type of transplantation significantly influenced RI and NRM for patients with acute leukemia and non-Hodgkin's lymphoma. There was no influence on RFS and OS. Conclusions: Both RI and NRM were significantly influenced by the size of the BED of single-dose or two-fraction TBI regimens; OS and RFS were not. Age was of highly significant influence on NRM, but there was no influence of age on RI. Hyperfractionated TBI with a high BED might be useful, assuming NRM can be reduced

  10. Simulation experiment on total ionization dose effects of linear CCD

    International Nuclear Information System (INIS)

    Tang Benqi; Zhang Yong; Xiao Zhigang; Wang Zujun; Huang Shaoyan

    2004-01-01

    We carry out the ionization radiation experiment of linear CCDs operated in unbiased, biased, biased and driven mode respectively by Co-60 γ source with our self-designed test system, and offline test the Dark signal and Saturation voltage and SNR varied with total dose for TCD132D, and get some valuable results. On the basis of above work, we set forth a primary experiment approaches to simulate the total dose radiation effects of charge coupled devices. (authors)

  11. Methods of assessing total doses integrated across pathways

    International Nuclear Information System (INIS)

    Grzechnik, M.; Camplin, W.; Clyne, F.; Allott, R.; Webbe-Wood, D.

    2006-01-01

    Calculated doses for comparison with limits resulting from discharges into the environment should be summed across all relevant pathways and food groups to ensure adequate protection. Current methodology for assessments used in the radioactivity in Food and the Environment (R.I.F.E.) reports separate doses from pathways related to liquid discharges of radioactivity to the environment from those due to gaseous releases. Surveys of local inhabitant food consumption and occupancy rates are conducted in the vicinity of nuclear sites. Information has been recorded in an integrated way, such that the data for each individual is recorded for all pathways of interest. These can include consumption of foods, such as fish, crustaceans, molluscs, fruit and vegetables, milk and meats. Occupancy times over beach sediments and time spent in close proximity to the site is also recorded for inclusion of external and inhalation radiation dose pathways. The integrated habits survey data may be combined with monitored environmental radionuclide concentrations to calculate total dose. The criteria for successful adoption of a method for this calculation were: Reproducibility can others easily use the approach and reassess doses? Rigour and realism how good is the match with reality?Transparency a measure of the ease with which others can understand how the calculations are performed and what they mean. Homogeneity is the group receiving the dose relatively homogeneous with respect to age, diet and those aspects that affect the dose received? Five methods of total dose calculation were compared and ranked according to their suitability. Each method was labelled (A to E) and given a short, relevant name for identification. The methods are described below; A) Individual doses to individuals are calculated and critical group selection is dependent on dose received. B) Individual Plus As in A, but consumption and occupancy rates for high dose is used to derive rates for application in

  12. Total dose effects on the matching properties of deep submicron MOS transistors

    International Nuclear Information System (INIS)

    Wang Yuxin; Hu Rongbin; Li Ruzhang; Chen Guangbing; Fu Dongbing; Lu Wu

    2014-01-01

    Based on 0.18 μm MOS transistors, for the first time, the total dose effects on the matching properties of deep submicron MOS transistors are studied. The experimental results show that the total dose radiation magnifies the mismatch among identically designed MOS transistors. In our experiments, as the radiation total dose rises to 200 krad, the threshold voltage and drain current mismatch percentages of NMOS transistors increase from 0.55% and 1.4% before radiation to 17.4% and 13.5% after radiation, respectively. PMOS transistors seem to be resistant to radiation damage. For all the range of radiation total dose, the threshold voltage and drain current mismatch percentages of PMOS transistors keep under 0.5% and 2.72%, respectively. (semiconductor devices)

  13. An experimental study on total dose effects in SRAM-based FPGAs

    International Nuclear Information System (INIS)

    Yao Zhibin; He Baoping; Zhang Fengqi; Guo Hongxia; Luo Yinhong; Wang Yuanming; Zhang Keying

    2009-01-01

    In order to study testing methods and find sensitive parameters in total dose effects on SRAM-based FPGA, XC2S100 chips were irradiated by 60 Co γ-rays and tested with two test circuit designs. By analyzing the experimental results, the test flow of configuration RAM and bock RAM was given, and the most sensitive parameter was obtained. The results will be a solid foundation for establishing test specification and evaluation methods of total dose effects on SRAM-based FPGAs. (authors)

  14. The Sandia total-dose estimator: SANDOSE description and user guide

    International Nuclear Information System (INIS)

    Turner, C.D.

    1995-02-01

    The SANdia total-DOSe Estimator (SANDOSE) is used to estimate total radiation dose to a (BRL-CAT) solid model, SANDOSE uses the mass-sectoring technique to sample the model using ray-tracing techniques. The code is integrated directly into the BRL-CAD solid model editor and is operated using a simple graphical user interface. Several diagnostic tools are available to allow the user to analyze the results. Based on limited validation using several benchmark problems, results can be expected to fall between a 10% underestimate and a factor of 2 overestimate of the actual dose predicted by rigorous radiation transport techniques. However, other situations may be encountered where the results might fall outside of this range. The code is written in C and uses X-windows graphics. It presently runs on SUN SPARCstations, but in theory could be ported to any workstation with a C compiler and X-windows. SANDOSE is available via license by contacting either the Sandia National Laboratories Technology Transfer Center or the author

  15. Dose rate and dose fractionation studies in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Netzel, B.; Schaffer, E.; Kolb, H.

    1979-01-01

    Total body irradiation (TBI) with 800-900 rads and allogeneic bone marrow transplantation according to the regimen designated by the Seattle group has induced remissions in patients with otherwise refractory acute leukemias. Relapse of leukemia after bone marrow transplantation remains the major problem, when the Seattle set up of two opposing 60 Co-sources and a low dose rate is used in TBI. Studies in dogs with TBI at various dose rates confirmed observations in mice that gastrointestinal toxicity is unlike toxicity against hemopoietic stem cells and possibly also leukemic stem cells depending on the dose rate. However, following very high single doses (2400 R) and marrow infusion acute gastrointestinal toxicity was not prevented by the lowest dose rate studied (0.5 R/min). Fractionated TBI with fractions of 600 R in addition to 1200 R (1000 rads) permitted the application of total doses up to 300 R followed by marrow infusion without irreversible toxicity. 26 dogs given 2400-3000 R have been observed for presently up to 2 years with regard to delayed radiation toxicity. This toxicity was mild in dogs given single doses at a low dose rate or fractionated TBI. Fractionated TBI is presently evaluated with allogeneic transplants in the dog before being applied to leukemic patients

  16. Single event effects and total ionizing dose effects of typical VDMOSFET devices

    International Nuclear Information System (INIS)

    Lou Jianshe; Cai Nan; Liu Jiaxin; Wu Qinzhi; Wang Jia

    2012-01-01

    In this work, single event effects and total ionizing dose effects of typical VDMOSFET irradiated by 60 Co γ-rays and 252 Cf source were studied. The single event burnout and single event gate rupture (SEB/SEGR) effects were investigated, and the relationship between drain-source breakdown voltage and ionizing dose was obtained. The results showed that the VDMOSFET devices were sensitive to SEB and SEGR, and measures to improve their resistance to SEB and SEGR should be considered seriously for their space applications. The drain-source breakdown voltage was sensitive to total ionizing dose effects as the threshold voltage. In assessing the devices' resistance to the total ionizing dose effects, both the threshold voltage and the drain-source breakdown voltage should be taken into account. (authors)

  17. Airborne and total gamma absorbed dose rates at Patiala - India

    International Nuclear Information System (INIS)

    Tesfaye, Tilahun; Sahota, H.S.; Singh, K.

    1999-01-01

    The external gamma absorbed dose rate due to gamma rays originating from gamma emitting aerosols in air, is compared with the total external gamma absorbed dose rate at the Physics Department of Punjabi University, Patiala. It has been found out that the contribution, to the total external gamma absorbed dose rate, of radionuclides on particulate matter suspended in air is about 20% of the overall gamma absorbed dose rate. (author)

  18. Effect of different doses of aerobic exercise on total white blood cell (WBC and WBC subfraction number in postmenopausal women: results from DREW.

    Directory of Open Access Journals (Sweden)

    Neil M Johannsen

    Full Text Available BACKGROUND: Elevated total white blood cell (WBC count is associated with an increased risk of coronary heart disease and death. Aerobic exercise is associated with lower total WBC, neutrophil, and monocyte counts. However, no studies have evaluated the effect of the amount of aerobic exercise (dose on total WBC and WBC subfraction counts. PURPOSE: To examine the effects of 3 different doses of aerobic exercise on changes in total WBC and WBC subfraction counts and independent effects of changes in fitness, adiposity, markers of inflammation (IL-6, TNF-α, C-reactive protein, fasting glucose metabolism, and adiponectin. METHODS: Data from 390 sedentary, overweight/obese postmenopausal women from the DREW study were used in these analyses. Women were randomized to a non-exercise control group or one of 3 exercise groups: energy expenditure of 4, 8, or 12 kcal kg(-1⋅week(-1 (KKW for 6 months at an intensity of 50% VO2peak. RESULTS: A dose-dependent decrease in total WBC counts (trend P = 0.002 was observed with a significant decrease in the 12KKW group (-163.1±140.0 cells/µL; mean±95%CI compared with the control (138.6±144.7 cells/µL. A similar response was seen in the neutrophil subfraction (trend P = 0.001 with a significant decrease in the 12KKW group (-152.6±115.1 cells/µL compared with both the control and 4KKW groups (96.4±119.0 and 21.9±95.3 cells/µL, respectively and in the 8KKW group (-102.4±125.0 cells/µL compared with the control. When divided into high/low baseline WBC categories (median split, a dose-dependent decrease in both total WBCs (P = 0.003 and neutrophils (P<0.001 was observed in women with high baseline WBC counts. The effects of exercise dose on total WBC and neutrophil counts persisted after accounting for significant independent effects of change in waist circumference and IL-6. CONCLUSION: Aerobic exercise training reduces total WBC and neutrophil counts, in a dose-dependent manner, in

  19. Dose calculation method with 60-cobalt gamma rays in total body irradiation

    International Nuclear Information System (INIS)

    Scaff, Luiz Alberto Malaguti

    2001-01-01

    Physical factors associated to total body irradiation using 60 Co gamma rays beams, were studied in order to develop a calculation method of the dose distribution that could be reproduced in any radiotherapy center with good precision. The method is based on considering total body irradiation as a large and irregular field with heterogeneities. To calculate doses, or doses rates, of each area of interest (head, thorax, thigh, etc.), scattered radiation is determined. It was observed that if dismagnified fields were considered to calculate the scattered radiation, the resulting values could be applied on a projection to the real size to obtain the values for dose rate calculations. In a parallel work it was determined the variation of the dose rate in the air, for the distance of treatment, and for points out of the central axis. This confirm that the use of the inverse square law is not valid. An attenuation curve for a broad beam was also determined in order to allow the use of absorbers. In this work all the adapted formulas for dose rate calculations in several areas of the body are described, as well time/dose templates sheets for total body irradiation. The in vivo dosimetry, proved that either experimental or calculated dose rate values (achieved by the proposed method), did not have significant discrepancies. (author)

  20. The total dose effects on the 1/f noise of deep submicron CMOS transistors

    International Nuclear Information System (INIS)

    Hu Rongbin; Wang Yuxin; Lu Wu

    2014-01-01

    Using 0.18 μm CMOS transistors, the total dose effects on the 1/f noise of deep-submicron CMOS transistors are studied for the first time in mainland China. From the experimental results and the theoretic analysis, we realize that total dose radiation causes a lot of trapped positive charges in STI (shallow trench isolation) SiO 2 layers, which induces a current leakage passage, increasing the 1/f noise power of CMOS transistors. In addition, we design some radiation-hardness structures on the CMOS transistors and the experimental results show that, until the total dose achieves 750 krad, the 1/f noise power of the radiation-hardness CMOS transistors remains unchanged, which proves our conclusion. (semiconductor devices)

  1. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    International Nuclear Information System (INIS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B.L.; Guha, Sujoy K.

    2010-01-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  2. Total dose and dose rate models for bipolar transistors in circuit simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Wix, Steven D.

    2013-05-01

    The objective of this work is to develop a model for total dose effects in bipolar junction transistors for use in circuit simulation. The components of the model are an electrical model of device performance that includes the effects of trapped charge on device behavior, and a model that calculates the trapped charge densities in a specific device structure as a function of radiation dose and dose rate. Simulations based on this model are found to agree well with measurements on a number of devices for which data are available.

  3. Theoretical considerations for SRAM total-dose hardening

    International Nuclear Information System (INIS)

    Francis, P.; Flandre, D.; Colinge, J.P.

    1995-01-01

    The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented

  4. Total dose and dose rate radiation characterization of EPI-CMOS radiation hardened memory and microprocessor devices

    International Nuclear Information System (INIS)

    Gingerich, B.L.; Hermsen, J.M.; Lee, J.C.; Schroeder, J.E.

    1984-01-01

    The process, circuit discription, and total dose radiation characteristics are presented for two second generation hardened 4K EPI-CMOS RAMs and a first generation 80C85 microprocessor. Total dose radiation performance is presented to 10M rad-Si and effects of biasing and operating conditions are discussed. The dose rate sensitivity of the 4K RAMs is also presented along with single event upset (SEU) test data

  5. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; Label, Kenneth A.; Ladbury, Raymond L.; Mondy, Timothy K.; O'Bryan, Martha V.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

  6. p-MOSFET total dose dosimeter

    Science.gov (United States)

    Buehler, Martin G. (Inventor); Blaes, Brent R. (Inventor)

    1994-01-01

    A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

  7. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  8. Determination of the total indicative dose in drinking and mineral waters

    International Nuclear Information System (INIS)

    Flesch, K.; Schulz, H.; Knappik, R.; Koehler, M.

    2006-01-01

    In Europe and Germany administrative regulations exist for the surveillance of the total indicative dose of water supplied for human consumption. This parameter, which cannot be analyzed directly, has to be calculated using nuclide specific activity concentration and age specific dose conversion factors and consumption rates. Available calculation methods differ regarding the used radionuclides, consumption rates and whether they use age specific dose conversion factors or not. In Germany administrative guidelines for the determination of the total indicative dose are still not available. As they have analyzed a large number of waters in the past, the authors derive a praxis orientated concept for the determination of the total indicative dose which respects radiological, analytical and hydrochemical aspects as well. Finally it is suggested to handle sparkling waters in the same manner as drinking waters. (orig.)

  9. Marrow toxicity of fractionated vs. single dose total body irradiation is identical in a canine model

    International Nuclear Information System (INIS)

    Storb, R.; Raff, R.F.; Graham, T.; Appelbaum, F.R.; Deeg, H.J.; Schuening, F.G.; Shulman, H.; Pepe, M.

    1993-01-01

    The authors explored in dogs the marrow toxicity of single dose total body irradiation delivered from two opposing 60 Co sources at a rate of 10 cGy/min and compared results to those seen with total body irradiation administered in 100 cGy fractions with minimum interfraction intervals of 6 hr. Dogs were not given marrow transplants. They found that 200 cGy single dose total body irradiation was sublethal, with 12 of 13 dogs showing hematopoietic recovery and survival. Seven of 21 dogs given 300 cGy single dose total body irradiation survived compared to 6 of 10 dogs given 300 cGy fractionated total body irradiation. One of 28 dogs given 400 cGy single dose total body irradiation survived compared to none of six given fractionated radiation. With granulocyte colony stimulating factor (GCSF) administered from day 0-21 after 400 cGy total body irradiation, most dogs survived with hematological recovery. Because of the almost uniform success with GCSF after 400 cGy single dose total body irradiation, a study of GCSF after 400 cGy fractionated total body irradiation was deemed not to be informative and, thus, not carried out. Additional comparisons between single dose and fractionated total body irradiation were carried out with GCSF administered after 500 and 600 cGy of total body irradiation. As with lower doses of total body irradiation, no significant survival differences were seen between the two modes of total body irradiation, and only 3 of 26 dogs studied survived with complete hematological recovery. Overall, therefore, survival among dogs given single dose total body irradiation was not different from that of dogs given fractionated total body irradiation (p = .67). Similarly, the slopes of the postirradiation declines of granulocyte and platelet counts and the rates of their recovery in surviving dogs given equal total doses of single versus fractionated total body irradiation were indistinguishable. 24 refs., 3 figs., 2 tabs

  10. Laboratory Bioaccumulation, Depuration And Total Dose Rate Of Waterborne Th-232 In Freshwater Fish Of Anabas Testudineus

    International Nuclear Information System (INIS)

    Zal U'yun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2014-01-01

    Preliminary results on the study of bioaccumulation, depuration and total dose rate of Th-232 in the whole body of Anabas testudineus are presented. The objective of this study was to evaluate the effect of Th-232 concentration activity on the laboratory bioaccumulation, depuration and total dose rate in Anabas testudineus. Anabas testudineus adults were exposed to different waterborne Th-232 levels: 0 BqL -1 (control), 50 BqL -1 and 100 BqL -1 for 30 day (uptake phase), followed by exposure to radionuclide-free water for 30 days (loss phase). Radionuclide concentration ratios between the whole body levels and water levels, percentage of Th-232 remaining in fish were calculated and total dose rates using ERICA Assessment Tool were also estimated. The results showed the increase of waterborne Th-232 concentration corresponded to a progressive increase of Th accumulation and total dose rate (internal and external) in the whole body of Anabas testudineus. Considering the ERICA dose rate screening value of 10 μGyh -1 , the findings can be concluded the estimated of total dose rate (< 5 μGyh -1 ) in Anabas testudineus is in order of small magnitude. Nevertheless, these preliminary results showed that the Anabas testudineus has a potential to accumulate thorium. (author)

  11. Estimation of the dose distribution within, and total dose to, the body of an acutely overexposed person

    International Nuclear Information System (INIS)

    Beer, G.P. de; Feather, J.I.; Oude, A. de; Language, A.E.

    1981-01-01

    In a case of accidental overexposure of a person, it is important to obtain a reliable value of the whole body dose as well as of the dose distribution within the body. Any follow-up treatment based only on the clinical effects as and when they appear, may result in insufficient or even erroneous therapy. In this respect knowledge of total dose and its distribution within the body may be a valuable aid in deciding on the follow-up treatment, taking into account the latent nature of the clinical effects. The calculated whole body dose and its distribution within the body of a person overexposed to a 192 Ir radiography source, are compared to experimentally determined values. In both cases the calculated values prove to be of sufficient accuracy to serve as an aid in decisions on the follow-up treatment. (author)

  12. Dose equivalent distributions in the AAEC total body nitrogen facility

    International Nuclear Information System (INIS)

    Allen, B.J.; Bailey, G.M.; McGregor, B.J.

    1985-01-01

    The incident neutron dose equivalent in the AAEC total body nitrogen facility is measured by a calibrated remmeter. Dose equivalent rates and distributions are calculated by Monte Carlo techniques which take account of the secondary neutron flux from the collimator. Experiment and calculation are found to be in satisfactory agreement. The effective dose equivalent per exposure is determined by weighting organ doses, and the potential detriment per exposure is calculated from ICRP risk factors

  13. Low-dose-rate total lymphoid irradiation: a new method of rapid immunosuppression

    International Nuclear Information System (INIS)

    Blum, J.E.; de Silva, S.M.; Rachman, D.B.; Order, S.E.

    1988-01-01

    Total Lymphoid Irradiation (TLI) has been successful in inducing immunosuppression in experimental and clinical applications. However, both the experimental and clinical utility of TLI are hampered by the prolonged treatment courses required (23 days in rats and 30-60 days in humans). Low-dose-rate TLI has the potential of reducing overall treatment time while achieving comparable immunosuppression. This study examines the immunosuppressive activity and treatment toxicity of conventional-dose-rate (23 days) vs low-dose-rate (2-7 days) TLI. Seven groups of Lewis rats were given TLI with 60Co. One group was treated at conventional-dose-rates (80-110 cGy/min) and received 3400 cGy in 17 fractions over 23 days. Six groups were treated at low-dose-rate (7 cGy/min) and received total doses of 800, 1200, 1800, 2400, 3000, and 3400 cGy over 2-7 days. Rats treated at conventional-dose-rates over 23 days and at low-dose-rate over 2-7 days tolerated radiation with minimal toxicity. The level of immunosuppression was tested using allogeneic (Brown-Norway) skin graft survival. Control animals retained allogeneic skin grafts for a mean of 14 days (range 8-21 days). Conventional-dose-rate treated animals (3400 cGy in 23 days) kept their grafts 60 days (range 50-66 days) (p less than .001). Low-dose-rate treated rats (800 to 3400 cGy total dose over 2-7 days) also had prolongation of allogeneic graft survival times following TLI with a dose-response curve established. The graft survival time for the 3400 cGy low-dose-rate group (66 days, range 52-78 days) was not significantly different from the 3400 cGy conventional-dose-rate group (p less than 0.10). When the total dose given was equivalent, low-dose-rate TLI demonstrated an advantage of reduced overall treatment time compared to conventional-dose-rate TLI (7 days vs. 23 days) with no increase in toxicity

  14. Total Risk Management for Low Dose Radiation Exposures

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Sterc, D.

    2012-01-01

    health. This view is supported with numerous evidences, and explained with beneficial effects from the increased activity of immune system activated with small radiation exposures. Finally, theory in between is that small doses are less than linearly proportionally harmful and that they are presenting a much smaller risks than according to the LNT. This view is derived from the use of different evidences. Difficulties to find one single theory about effects of small radiation doses are related to existence of huge variability and uncertainty in the evidence data. This is very hard experimental and theoretical problem. It will require lots of additional research to reduce these uncertainties and find final theory. This might be too late for the number of people affected in different ways with current single most conservative LNT approach. The problem with the conservative LNT regulatory approach is resulting in enormous additional costs of nuclear energy and medical applications. Which is reasonable and acceptable during the regular operation when source is high and concentrated. But, this becomes unreasonable huge economic burden after accidents and for cleanups with nuclear facilities. Similar problem arises with restriction of medical examinations and treatments based on over conservative risk estimate. Special circumstances are with evacuated people from contaminated areas where they are on the one side saved from small radiation exposures, and on the other side exposed to years of life away from their home and with numerous direct and indirect additional risks (i.e., stress, social problems, etc.). It seems reasonable that some alternative (total) risk management approach might be much more suitable for this situation. Evacuation of people from contaminated area with small doses sources should not be done when that induces larger risks from even what is expected from radiation based on LNT. Similar total risk management could be also applied for with medical

  15. Total dose effects on ATLAS-SCT front-end electronics

    CERN Document Server

    Ullán, M; Dubbs, T; Grillo, A A; Spencer, E; Seiden, A; Spieler, H; Gilchriese, M G D; Lozano, M

    2002-01-01

    Low dose rate effects (LDRE) in bipolar technologies complicate the hardness assurance testing for high energy physics applications. The damage produced in the ICs in the real experiment can be underestimated if fast irradiations are carried out, while experiments done at the real dose rate are usually unpractical due to the still high total doses involved. In this work the sensitivity to LDRE of two bipolar technologies proposed for the ATLAS-SCT experiment at CERN is evaluated, finding one of them free of those effects. (12 refs).

  16. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  17. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  18. Total dose hardness of a commercial SiGe BiCMOS technology

    International Nuclear Information System (INIS)

    Van Vonno, N.; Lucas, R.; Thornberry, D.

    1999-01-01

    Over the past decade SiGe HBT technology has progress from the laboratory to actual commercial applications. When integrated into a BiMOS process, this technology has applications in low-cost space systems. In this paper, we report results of total dose testing of a SiGe/CMOS process accessible through a commercial foundry. (authors)

  19. Relative effect of radiation dose rate on hemopoietic and nonhemopoietic lethality of total-body irradiation

    International Nuclear Information System (INIS)

    Peters, L.J.; McNeill, J.; Karolis, C.; Thames, H.D. Jr.; Travis, E.L.

    1986-01-01

    Experiments were undertaken to determine the influence of dose rate on the toxicity of total-body irrdiation (TBI) with and without syngeneic bone-marrow rescue in mice. The results showed a much greater dose-rate dependence for death from nonhemopoietic toxicity than from bone-marrow ablation, with the ratio of LD 50 's increasing from 1.73 at 25 cGy/min to 2.80 at 1 cGy/min. At the higher dose rates, dose-limiting nonhemopoietic toxicity resulted from late organ injury, affecting the lungs, kidneys, and liver. At 1 cGy/min the major dose-limiting nonhemopoietic toxicity was acute gastrointestinal injury. The implications of these results in the context of TBI in preparation for bone-marrow transplantation are discussed. 15 refs., 4 figs

  20. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kalend, A [Pittsburgh University School of Medicine (USA). Department of Radiation Oncology Pittsburg Cancer Institute (USA)

    1990-03-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab.

  1. Use of normalized total dose to represent the biological effect of fractionated radiotherapy

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Kalend, A.

    1990-01-01

    There are currently a number of radiobiological models to account for the effects of dose fractionation and time. Normalized total dose (NTD) is not another new model but is a previously reported, clinically useful form in which to represent the biological effect, determined by any specific radiobiological dose-fractionation model, of a course of radiation using a single set of standardized, easily understood terminology. The generalized form of NTD reviewed in this paper describes the effect of a course of radiotherapy administered with nonstandard fractionation as the total dose of radiation in Gy that could be administered with a given reference fractionation such as 2 Gy per fraction, 5 fractions per week that would produce an equivalent biological effect (probability of complications or tumor control) as predicted by a given dose-fractionation formula. The use of normalized total dose with several different exponential and linear-quadratic dose-fraction formulas is presented. (author). 51 refs.; 1 fig.; 1 tab

  2. Simulation of Shielding Effects on the Total Dose Observed in TDE of KISAT-1

    Directory of Open Access Journals (Sweden)

    Sung-Joon Kim

    2001-06-01

    Full Text Available The threshold voltage shift observed in TDE (Total Dose Experiment on board the KITSAT-1 is converted into dose (rad(SiO2 usinsg the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute. Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  3. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    International Nuclear Information System (INIS)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor; Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette

    2017-01-01

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D mean ), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D mean was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m 2 , with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D mean exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [de

  4. Total 2004 results

    International Nuclear Information System (INIS)

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  5. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  6. Total 2004 results

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-02-01

    This document presents the 2004 results of Total Group: consolidated account, special items, number of shares, market environment, adjustment for amortization of Sanofi-Aventis merger-related intangibles, 4. quarter 2004 results (operating and net incomes, cash flow), upstream (results, production, reserves, recent highlights), downstream (results, refinery throughput, recent highlights), chemicals (results, recent highlights), Total's full year 2004 results (operating and net income, cash flow), 2005 sensitivities, Total SA parent company accounts and proposed dividend, adoption of IFRS accounting, summary and outlook, main operating information by segment for the 4. quarter and full year 2004: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refined product sales by region, chemicals), Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  7. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Flament, O.; Paillet, P.; Leray, J.L.

    1999-01-01

    Radiation-induced hole and electron transport and trapping are fundamental to MOS total-dose models. Here we separate the effects of electron-hole annihilation and electron trapping on the neutralization of radiation-induced charge during switched-bias irradiation for hard and soft oxides, via combined thermally stimulated current (TSC) and capacitance-voltage measurements. We also show that present total-dose models cannot account for the thermal stability of deeply trapped electrons near the Si/SiO 2 interface, or the inability of electrons in deep or shallow traps to contribute to TSC at positive bias following (1) room-temperature, (2) high-temperature, or (3) switched-bias irradiation. These results require revisions of modeling parameters and boundary conditions for hole and electron transport in SiO 2 . The nature of deep and shallow electron traps in the near-interfacial SiO 2 is discussed

  8. Estimation of the Radon-induced Dose for Russia's Population: Methods and Results

    International Nuclear Information System (INIS)

    Marenny, A.M.; Savkin, M.N.; Shinkarev, S.M.

    2000-01-01

    A model is proposed for inferring the radon-induced annual average collective and personal doses, as well as the dose distribution of the population, all over Russia from selective radon monitoring in some regions of Russia. The model assumptions and the selective radon monitoring results that underlie the numerical estimates obtained for different population groups are presented. The current estimate of the collective radon-induced dose received by the population of Russia (148,100,000 as of 1996) is about 130,000 man Sv, of which 55,000 man Sv is for the rural population (27% of the total population) and 75,000 man Sv for the urban population (73% of the total). The average radon-induced personal dose in Russia is estimated to be about 0.87 mSv. About 1,000,000 people receive annual doses above 10 mSv, including some 200,000 people who receive doses above 20 mSv annually. The ways of making the current estimates more accurate are outlined. (author)

  9. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  10. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co γ rays in a specially constructed facility. The exposure rates were either 5, 10, 17, or 35 R/day, and the exposures were terminated at either 600, 1400, 2000, or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for γ-ray exposures given at a number of exposure rates. They also allow comparison of the relative importance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 258 rad delivered at 15 R/minute to approximately 3000 rad at 10 R/day. Over this entire range, the LD 50 is dependent upon hematopoietic damage. At 5 R/day and less, no meaningful LD 50 can be determined; there is nearly normal continued hematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in other organ systems. Although the experiment is not complete, interim data allow several important conclusions. Terminated exposures, while not as effective as radiation continued until death, can produce myelogenous leukemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates are more damaging than higher rates on the basis of the rate and degree of hematological recovery that occurs after termination of irradiation. Thus, the rate of hematologic depression, the nadir of the depression, and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the former two are directly related to exposure rate

  11. Relationship of dose rate and total dose to responses of continuously irradiated beagles

    International Nuclear Information System (INIS)

    Fritz, T.E.; Norris, W.P.; Tolle, D.V.; Seed, T.M.; Poole, C.M.; Lombard, L.S.; Doyle, D.E.

    1978-01-01

    Young-adult beagles were exposed continuously (22 hours/day) to 60 Co gamma rays in a specially constructed facility. The exposure rates were 5, 19, 17 or 35 R/day, and the exposures were terminated at 600, 1400, 2000 or 4000 R. A total of 354 dogs were irradiated; 221 are still alive as long-term survivors, some after more than 2000 days. The data on survival of these dogs, coupled with data from similar preliminary experiments, allow an estimate of the LD 50 for gamma-ray exposures given at a number of exposure rates. They also allow comparison of the relativeimportance of dose rate and total dose, and the interaction of these two variables, in the early and late effects after protracted irradiation. The LD 50 for the beagle increases from 344 R (258 rads) delivered at 15 R/minute to approximately 4000 R (approximately 3000 rads) at 10 R/day. Over this entire range, the LD 50 is dependent upon haematopoietic damage. At 5 R/day and less, no definitive LD 50 can be determined; there is nearly normal continued haematopoietic function, survival is prolonged, and the dogs manifest varied individual responses in the organ systems. Although the experiment is not complete, interim data allow serveral important conclusions. Terminated exposures, while not as effective as irradiation continued until death, can produce myelogenous leukaemia at the same exposure rate, 10 R/day. More importantly, at the same total accumulated dose, lower exposure rates appear more damaging than higher rates on the basis of the rate and degree of haematological recovery that occurs after termination of irradiation. Thus, the rate of haematologic depression, the nadir of the depression and the rate of recovery are dependent upon exposure rate; the latter is inversely related and the first two are directly related to exposure rate. ( author)

  12. Enchanced total dose damage in junction field effect transistors and related linear integrated circuits

    International Nuclear Information System (INIS)

    Flament, O.; Autran, J.L.; Roche, P.; Leray, J.L.; Musseau, O.

    1996-01-01

    Enhanced total dose damage of Junction Field-effect Transistors (JFETs) due to low dose rate and/or elevated temperature has been investigated for elementary p-channel structures fabricated on bulk and SOI substrates as well as for related linear integrated circuits. All these devices were fabricated with conventional junction isolation (field oxide). Large increases in damage have been revealed by performing high temperature and/or low dose rate irradiations. These results are consistent with previous studies concerning bipolar field oxides under low-field conditions. They suggest that the transport of radiation-induced holes through the oxide is the underlying mechanism. Such an enhanced degradation must be taken into account for low dose rate effects on linear integrated circuits

  13. Application of a Pelletron accelerator to study total dose radiation effects on 50 GHz SiGe HBTs

    Energy Technology Data Exchange (ETDEWEB)

    Praveen, K.C.; Pushpa, N.; Naik, P.S. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India); Cressler, John D. [School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA (United States); Tripathi, Ambuj [Inter University Accelerator Centre (IUAC), New Delhi 110 067 (India); Gnana Prakash, A.P., E-mail: gnanaprakash@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570 006 (India)

    2012-02-15

    Highlights: Black-Right-Pointing-Pointer Total dose effects of 50 MeV Li3+ ion on 50 GHz SiGe HBTs is investigated. Black-Right-Pointing-Pointer Ion irradiated results were compared with Co-60 gamma results. Black-Right-Pointing-Pointer 50 MeV Li ions create more damage in E-B spacer oxide when compared to Co-60 gamma radiation. Black-Right-Pointing-Pointer Co-60 gamma radiation create more damage in STI oxide when compared to 50 MeV Li ions. Black-Right-Pointing-Pointer Worst case total dose radiation effects can be studied using Pelletron accelerator facilities. - Abstract: We have investigated the effects of 50 MeV lithium ion irradiation on the DC electrical characteristics of first-generation silicon-germanium heterojunction bipolar transistors (50 GHz SiGe HBTs) in the dose range of 600 krad to 100 Mrad. The results of 50 MeV Li{sup 3+} ion irradiation on the SiGe HBTs are compared with 63 MeV proton and Co-60 gamma irradiation results in the same dose range in order to understand the damage induced by different LET species. The radiation response of emitter-base (EB) spacer oxide and shallow trench isolation (STI) oxide to different irradiation types are discussed in this paper. We have also focused on the efficacy in the application of a Pelletron accelerator to study total dose irradiation studies in SiGe HBTs.

  14. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  15. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Healy, W.L.; Lo, T.C.; Covall, D.J.; Pfeifer, B.A.; Wasilewski, S.A.

    1990-01-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700 centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy

  16. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  17. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  18. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  19. Estimation of the total absorbed dose by quartz in retrospective conditions

    International Nuclear Information System (INIS)

    Correcher, V.; Delgado, A.

    2003-01-01

    The estimation of the total absorbed dose is of great interest in areas affected by a radiological accident when no conventional dosimetric systems are available. This paper reports about the usual methodology employed in dose reconstruction from the thermoluminescence (TL) properties of natural quartz, extracted from selected ceramic materials (12 bricks) picked up in the Chernobyl area. It has been possible to evaluate doses under 50mGy after more than 11 years later since the radiological accident happened. The main advance of this fact is the reduction of the commonly accepted limit dose estimation more than 20 times employing luminescence methods. (Author) 11 refs

  20. Analytical models for total dose ionization effects in MOS devices.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Bogdan, Carolyn W.

    2008-08-01

    MOS devices are susceptible to damage by ionizing radiation due to charge buildup in gate, field and SOI buried oxides. Under positive bias holes created in the gate oxide will transport to the Si / SiO{sub 2} interface creating oxide-trapped charge. As a result of hole transport and trapping, hydrogen is liberated in the oxide which can create interface-trapped charge. The trapped charge will affect the threshold voltage and degrade the channel mobility. Neutralization of oxidetrapped charge by electron tunneling from the silicon and by thermal emission can take place over long periods of time. Neutralization of interface-trapped charge is not observed at room temperature. Analytical models are developed that account for the principal effects of total dose in MOS devices under different gate bias. The intent is to obtain closed-form solutions that can be used in circuit simulation. Expressions are derived for the aging effects of very low dose rate radiation over long time periods.

  1. Study of total ionization dose effects in electronic devices

    International Nuclear Information System (INIS)

    Nidhin, T.S.; Bhattacharyya, Anindya; Gour, Aditya; Behera, R.P.; Jayanthi, T.

    2018-01-01

    Radiation effects in electronic devices are a major challenge in the dependable application developments of nuclear power plant instrumentation and control systems. The main radiation effects are total ionization dose (TID) effects, displacement damage dose (DDD) effects and single event effects (SEE). In this study, we are concentrating on TID effects in electronic devices. The focus of the study is mainly on SRAM based field programmable gate arrays (FPGA) along with that the devices of our interest are voltage regulators, flash memory and optocoupler. The experiments are conducted by exposing the devices to gamma radiation in power off condition and the degradation in the performances are analysed

  2. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  3. Three-dimensional Finite Elements Method simulation of Total Ionizing Dose in 22 nm bulk nFinFETs

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikyriakou, Eleni, E-mail: ec3g12@soton.ac.uk; Potter, Kenneth; Redman-White, William; De Groot, C.H.

    2017-02-15

    Highlights: • Simulation of Total Ionizing Dose using the Finite Elements Method. • Carrier generation, transport and trapping in the oxide. • Application in three-dimensional bulk FinFET model of 22 nm node. • Examination of trapped charge in the Shallow Trench Isolation. • Trapped charge dependency of parasitic transistor current. - Abstract: Finite Elements Method simulation of Total Ionizing Dose effects on 22 nm bulk Fin Field Effect Transistor (FinFET) devices using the commercial software Synopsys Sentaurus TCAD is presented. The simulation parameters are extracted by calibrating the charge trapping model to experimental results on 400 nm SiO{sub 2} capacitors irradiated under zero bias. The FinFET device characteristics are calibrated to the Intel 22 nm bulk technology. Irradiation simulations of the transistor performed with all terminals unbiased reveal increased hardness up to a total dose of 1 MRad(SiO{sub 2}).

  4. Test methods of total dose effects in very large scale integrated circuits

    International Nuclear Information System (INIS)

    He Chaohui; Geng Bin; He Baoping; Yao Yujuan; Li Yonghong; Peng Honglun; Lin Dongsheng; Zhou Hui; Chen Yusheng

    2004-01-01

    A kind of test method of total dose effects (TDE) is presented for very large scale integrated circuits (VLSI). The consumption current of devices is measured while function parameters of devices (or circuits) are measured. Then the relation between data errors and consumption current can be analyzed and mechanism of TDE in VLSI can be proposed. Experimental results of 60 Co γ TDEs are given for SRAMs, EEPROMs, FLASH ROMs and a kind of CPU

  5. Revisiting Low-Dose Total Skin Electron Beam Therapy in Mycosis Fungoides

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Cameron, E-mail: cameronh@stanford.edu [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Young, James; Navi, Daniel [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Riaz, Nadeem [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States); Lingala, Bharathi; Kim, Youn [Department of Dermatology, Stanford Cancer Center, Stanford, California (United States); Hoppe, Richard [Department of Radiation Oncology, Stanford Cancer Center, Stanford, California (United States)

    2011-11-15

    Purpose: Total skin electron beam therapy (TSEBT) is a highly effective treatment for mycosis fungoides (MF). The standard course consists of 30 to 36 Gy delivered over an 8- to 10-week period. This regimen is time intensive and associated with significant treatment-related toxicities including erythema, desquamation, anhydrosis, alopecia, and xerosis. The aim of this study was to identify a lower dose alternative while retaining a favorable efficacy profile. Methods and Materials: One hundred two MF patients were identified who had been treated with an initial course of low-dose TSEBT (5-<30 Gy) between 1958 and 1995. Patients had a T stage classification of T2 (generalized patch/plaque, n = 51), T3 (tumor, n = 29), and T4 (erythrodermic, n = 22). Those with extracutaneous disease were excluded. Results: Overall response (OR) rates (>50% improvement) were 90% among patients with T2 to T4 disease receiving 5 to <10 Gy (n = 19). In comparison, OR rates between the 10 to <20 Gy and 20 to <30 Gy subgroups were 98% and 97%, respectively. There was no significant difference in median progression free survival (PFS) in T2 and T3 patients when stratified by dose group, and PFS in each was comparable to that of the standard dose. Conclusions: OR rates associated with low-dose TSEBT in the ranges of 10 to <20 Gy and 20 to <30 Gy are comparable to that of the standard dose ({>=} 30 Gy). Efficacy measures including OS, PFS, and RFS are also favorable. Given that the efficacy profile is similar between 10 and <20 Gy and 20 and <30 Gy, the utility of TSEBT within the lower dose range of 10 to <20 Gy merits further investigation, especially in the context of combined modality treatment.

  6. Clinical responses after total body irradiation by over permissible dose of γ-rays in one time

    International Nuclear Information System (INIS)

    Jiang Benrong; Wang Guilin; Liu Huilan; Tang Xingsheng; Ai Huisheng

    1990-01-01

    The clinical responses of patients after total body over permissilbe dose γ-ray irradiation were observed and analysed. The results showed: when the dose was above 5 cGy, there was some immunological depression, but no significant change in hematopoietic functions. 5 cases showed some transient changes of ECG, perhaps due to vagotonia caused by psychological imbalance, One case vomitted 3-4 times after 28 cGy irradiation, this suggested that a few times of vomitting had no significance in the estimation of the irradiated dose and the whole clinical manifestations must be concretely analysed

  7. Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Kal, H.B.; Kempen-Harteveld, M.L. van; Heijenbrok-Kal, M.H.; Struikmans, H.

    2006-01-01

    Background and Purpose: Total-body irradiation (TBI) is an important part of the conditioning regimen for hematopoietic stem cell transplantation (HSCT) in patients with hematologic malignancies. The results after treatment with various TBI regimes were compared, and dose-effect relationships for the endpoints relapse incidence, disease-free survival, treatment-related mortality, and overall survival were derived. The aim was to define requirements for an optimal treatment schedule with respect to leukemic cell kill and late normal-tissue morbidity. Material and Methods: A literature search was performed. Three randomized studies, four studies comparing results of two or three TBI regimens, and nine reports with results of one specific TBI regimen were identified. Biologically effective doses (BEDs) were calculated. The results of the randomized studies and the studies comparing results of two or three TBI regimens were pooled, and the pooled relative risk (RR) was calculated for the treatments with high BED values versus treatments with a low BED. BED-effect relationships were obtained. Results: RRs for the high BED treatments were significantly lower for relapse incidence, not significantly different for disease-free survival and treatment-related mortality, and significantly higher for overall survival. BED-effect relationships indicate a decrease in relapse incidence and treatment-related mortality and an increase in disease-free and overall survival with higher BED values. Conclusion: 'More dose is better', provided that a TBI setting is used limiting the BEDs of lungs, kidneys, and eye lenses. (orig.)

  8. Monitoring of doses to patients in interventional cardiology: first results from three Serbian hospitals

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, Olivera; Arandjic, Danijela; Kosutic, Dushko

    2010-01-01

    The aim of this work is to assess level of radiation dose to patients in interventional cardiology procedures in three large Serbian hospitals and to investigate possibility for setting of trigger levels if dose quantities exceed certain levels. Three dedicated interventional cardiology laboratories were included in the survey. Information on annual workload was estimated based on number of coronary angiography (CA) procedures and percutaneous coronary interventions (PCI). Patients doses were assessed in terms of air kerma area product (PKA) and air kerma in international reference point (KIRP). Results were compared with internationally proposed Diagnostic Reference Levels (DRL) and similar surveys results. Average total annual number of procedures was 820, 1100 and 2500 in three hospitals, respectively, while total number of dose measurements was 337. All three centers reported PKA values higher than 100 Gy·cm 2 and even values above 200 Gy·cm 2 , corresponding to 42% and 16% of all measurements. Measured KIRP value higher than 5 Gy was reported in one center, indicating that skin doses associated possibility of skin injuries were observed. PKA mean hospital values for CA ranged from 33 to 78 Gy·cm 2 and for PCI from 73 to 113 Gy·cm 2 , while associated vales for KIRP were: 0.45-1.2 Gy and 1.1-1.8 Gy, respectively. Comparison of obtained results with international DRL indicated that significant number of procedures is not optimally performed as in some centers more than a half of patients receive doses above DRL. The presented results are valuable input for dose optimization strategies and increased awareness related to importance of dose management. With respect to high dose values, risk for stochastic effects and tissue reactions, dose management methods were proposed. (Author)

  9. Serum protein concentration in low-dose total body irradiation of normal and malnourished rats

    International Nuclear Information System (INIS)

    Viana, W.C.M.; Lambertz, D.; Borges, E.S.; Neto, A.M.O.; Lambertz, K.M.F.T.; Amaral, A.

    2016-01-01

    Among the radiotherapeutics' modalities, total body irradiation (TBI) is used as treatment for certain hematological, oncological and immunological diseases. The aim of this study was to evaluate the long-term effects of low-dose TBI on plasma concentration of total protein and albumin using prematurely and undernourished rats as animal model. For this, four groups with 9 animals each were formed: Normal nourished (N); Malnourished (M); Irradiated Normal nourished (IN); Irradiated Malnourished (IM). At the age of 28 days, rats of the IN and IM groups underwent total body gamma irradiation with a source of cobalt-60. Total protein and Albumin in the blood serum was quantified by colorimetry. This research indicates that procedures involving low-dose total body irradiation in children have repercussions in the reduction in body-mass as well as in the plasma levels of total protein and albumin. Our findings reinforce the periodic monitoring of total serum protein and albumin levels as an important tool in long-term follow-up of pediatric patients in treatments associated to total body irradiation. - Highlights: • Low-dose total body irradiation (TBI) in children have repercussions in their body-mass. • Long-term total protein and albumin levels are affected by TBI. • The monitoring of total protein and albumin levels are useful in the follow-up of TBI pediatric patients.

  10. Worst-Case Bias During Total Dose Irradiation of SOI Transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Colladant, T.; Paillet, P.; Leray, J.-L; Musseau, O.; Schwank, James R.; Shaneyfelt, Marty R.; Pelloie, J.L.; Du Port de Poncharra, J.

    2000-01-01

    The worst case bias during total dose irradiation of partially depleted SOI transistors (from SNL and from CEA/LETI) is correlated to the device architecture. Experiments and simulations are used to analyze SOI back transistor threshold voltage shift and charge trapping in the buried oxide

  11. Dose compensation of the total body irradiation therapy

    International Nuclear Information System (INIS)

    Lin, J.-P.; Chu, T.-C.; Liu, M.-T.

    2001-01-01

    The aim of the study is to improve dose uniformity in the body by the compensator-rice and to decrease the dose to the lung by the partial lung block. Rando phantom supine was set up to treat bilateral fields with a 15 MV linear accelerator at 415 cm treatment distance. The experimental procedure included three parts. The first part was the bilateral irradiation without rice compensator, and the second part was with rice compensator. In the third part, rice compensator and partial lung block were both used. The results of thermoluminescent dosimeters measurements indicated that without rice compensator the dose was non-uniform. Contrarily, the average dose homogeneity with rice compensator was measured within ±5%, except for the thorax region. Partial lung block can reduce the dose which the lung received. This is a simple method to improve the dose homogeneity and to reduce the lung dose received. The compensator-rice is cheap, and acrylic boxes are easy to obtain. Therefore, this technique is suitable for more studies

  12. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Arican, Zumre; Bar-Deroma, Raquel; Tamir, Ada; Kuten, Abraham

    2003-01-01

    In this study, in vivo dosimetic data of 67 total skin electron irradiation (TSEI) treatments were analyzed. Thermoluminescent dosimetry (TLD) measurements were made at 10 different body points for every patient. The results demonstrated that the dose inhomogeneity throughout the skin surface is around 15%. The homogeneity was better at the trunk than at the extratrunk points, and was worse when a degrader was used. There was minimal improvement of homogeneity in subsequent days of treatment

  13. Concentration of total proteins in blood plasma of chickens hatched from irradiated eggs with low dose gamma radiation

    International Nuclear Information System (INIS)

    Vilic, M.; Kraljevic, P.; Miljanic, S.; Simpraga, M.

    2005-01-01

    It is known that low-dose ionising radiation may have stimulating effects on chickens. Low doses may also cause changes in the concentration of blood plasma total proteins, glucose and cholesterol in chickens. This study investigates the effects of low dose gamma-radiation on the concentration of total proteins in the blood plasma of chickens hatched from eggs irradiated with a dose of 0.15 Gy on incubation days 7 and 19. Results were compared with the control group (chickens hatched from non-irradiated eggs). After hatching, all other conditions were the same for both groups. Blood samples were drawn from the heart, and later from the wing vein on days 1, 3, 5, 7,10, 20, 30 and 42. The concentration of total proteins was determined spectrophotometrically using Boehringer Mannheim GmbH optimised kits. The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 7 showed a statistically significant decrease on the sampling day 3 (P less than 0.05) and 7 (P less than 0.01). The concentration of total proteins in blood plasma in chickens hatched from eggs irradiated with 0.15 Gy on incubation day 19 showed a statistically significant increase only on sampling day 1 (P less than 0.05). These results suggest that exposure of eggs to 0.15 Gy of gamma-radiation on the 7th and 19th day of incubation could produce different effects on the protein metabolism in chickens.(author)

  14. Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and Selected NASA Electronic Parts and Packaging Program

    Science.gov (United States)

    Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Mondy, Timothy K.; hide

    2017-01-01

    Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  15. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    International Nuclear Information System (INIS)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G.

    2002-01-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7±17.1 and 40.4±16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7±4.8 ccm for 3D-HOF and 10.7±12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma

  16. Modelling normal tissue isoeffect distribution in conformal radiotherapy of glioblastoma provides an alternative dose escalation pattern through hypofractionation without reducing the total dose

    Energy Technology Data Exchange (ETDEWEB)

    Mangel, L.; Skriba, Z.; Major, T.; Polgar, C.; Fodor, J.; Somogyi, A.; Nemeth, G. [National Research Inst. for Radiobiology and Radiohygiene, Budapest (Hungary)

    2002-04-01

    The purpose of this study was to prove that by using conformal external beam radiotherapy (RT) normal brain structures can be protected even when applying an alternative approach of biological dose escalation: hypofractionation (HOF) without total dose reduction (TDR). Traditional 2-dimensional (2D) and conformal 3-dimensional (3D) treatment plans were prepared for 10 gliomas representing the subanatomical sites of the supratentorial brain. Isoeffect distributions were generated by the biologically effective dose (BED) formula to analyse the effect of conventionally fractionated (CF) and HOF schedules on both the spatial biological dose distribution and biological dose-volume histograms. A comparison was made between 2D-CF (2.0 Gy/day) and 3D-HOF (2.5 Gy/day) regimens, applying the same 60 Gy total doses. Integral biologically effective dose (IBED) and volumes received biologically equivalent to a dose of 54 Gy or more (V-BED54) were calculated for the lower and upper brain stem as organs of risk. The IBED values were lower with the 3D-HOF than with the 2D-CF schedule in each tumour location, means 22.7{+-}17.1 and 40.4{+-}16.9 in Gy, respectively (p<0.0001). The V-BED54 values were also smaller or equal in 90% of the cases favouring the 3D-HOF scheme. The means were 2.7{+-}4.8 ccm for 3D-HOF and 10.7{+-}12.7 ccm for 2D-CF (p=0.0006). Our results suggest that with conformal RT, fraction size can gradually be increased. HOF radiotherapy regimens without TDR shorten the treatment time and seem to be an alternative way of dose escalation in the treatment of glioblastoma.

  17. Total 2003 Results

    International Nuclear Information System (INIS)

    2003-01-01

    This document presents the 2003 results of Total Group: consolidated account, special items, number of shares, market environment, 4. quarter 2003 results, full year 2003 results, upstream (key figures, proved reserves), downstream key figures, chemicals key figures, parent company accounts and proposed dividends, 2004 sensitivities, summary and outlook, operating information by segment for the 4. quarter and full year 2003: upstream (combined liquids and gas production by region, liquids production by region, gas production by region), downstream (refinery throughput by region, refined product sales by region, chemicals), impact of allocating contribution of Cepsa to net operating income by business segment: equity in income (loss) and affiliates and other items, Total financial statements: consolidated statement of income, consolidated balance sheet (assets, liabilities and shareholder's equity), consolidated statements of cash flows, business segments information. (J.S.)

  18. High-dose total-body irradiation and autologous marrow reconstitution in dogs: dose-rate-related acute toxicity and fractionation-dependent long-term survival

    International Nuclear Information System (INIS)

    Deeg, H.J.; Storb, R.; Weiden, P.L.; Schumacher, D.; Shulman, H.; Graham, T.; Thomas, E.D.

    1981-01-01

    Beagle dogs treated by total-body irradiation (TBI) were given autologous marrow grafts in order to avoid death from marrow toxicity. Acute and delayed non-marrow toxicities of high single-dose (27 dogs) and fractionated TBI (20 dogs) delivered at 0.05 or 0.1 Gy/min were compared. Fractionated TBI was given in increments of 2 Gy every 6 hr for three increments per day. Acute toxicity and early mortality (<1 month) at identical total irradiation doses were comparable for dogs given fractionated or single-dose TBI. With single-dose TBI, 14, 16, and 18 Gy, respectively, given at 0.05 Gy/min, 0/5, 5/5, and 2/2 dogs died from acute toxicity; with 10, 12, and 14 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 5/5 dogs died acutely. With fractionated TBI, 14 and 16 Gy, respectively, given at 0.1 Gy/min, 1/5, 4/5, and 2/2 dogs died auctely. Early deaths were due to radiation enteritis with or without associated septicemia (29 dogs; less than or equal to Day 10). Three dogs given 10 Gy of TBI at 0.1 Gy/min died from bacterial pneumonia; one (Day 18) had been given fractionated and two (Days 14, 22) single-dose TBI. Fifteen dogs survived beyond 1 month; eight of these had single-dose TBI (10-14 Gy) and all died within 7 months of irradiation from a syndrome consisting of hepatic damage, pancreatic fibrosis, malnutrition, wasting, and anemia. Seven of the 15 had fractionated TBI, and only one (14 Gy) died on Day 33 from hepatic failure, whereas 6 (10-14 Gy) are alive and well 250 to 500 days after irradiation. In conclusion, fractionated TBI did not offer advantages over single-dose TBI with regard to acute toxicity and early mortality; rather, these were dependent upon the total dose of TBI. The total acutely tolerated dose was dependent upon the exposure rate; however, only dogs given fractionated TBI became healthy long-term survivors

  19. Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

    International Nuclear Information System (INIS)

    Molloy, Janelle A.

    2010-01-01

    Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than ±10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times

  20. The effect of low-dose total body irradiation on tumor control

    International Nuclear Information System (INIS)

    Sakamoto, Kiyohiko; Miyamoto, Miyako; Watabe, Nobuyuki.

    1987-01-01

    Total body irradiation (TBI) is considered to bring about an immunosuppressive effect on an organism, on the basis of data obtained from sublethal doses of TBI. However, there are no data on how low-dose TBI affects an organism. Over the last five years, we have been studying the effects of low-dose TBI on normal or tumor-bearing mice and the immunological background of these effects. In experimental studies, an increase in the TD50 value (the number of cells required for a tumor incidence of 50 %) in mice exposed to 10 rad was recognized and showed a remarkable increase at 6 hours to 15 hours after irradiation. TBI of 10 rad also showed an enhancement effect on tumor cell killing when given 12 hours before local tumor irradiation. In order to clarify the mechanism of this kind of effect, some immunological studies were performed using several immunological procedures, and the results suggested that 10 rad of TBI caused increasing tumor immunity in irradiated mice. Clinical trials in some patients with advanced tumors are now being undertaken on the basis of these experimental data, and the effect of TBI on tumor control appears promising, although it is too early to draw conclusions. (author)

  1. Dose characteristics of total-skin electron-beam irradiation with six-dual electron fields

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1998-01-01

    To obtain the uniform dose at limited depth to entire surface of the body, the dose characteristics of degraded electron beam of the large target-skin distance and the dose distribution of the six-dual electron fields were investigated. The experimental dose distributions included the depth dose curve, spatial dose and attenuated electron beam were determined with 300 cm of Target-Skin Distance (TSD) and full collimator size (35x35 cm 2 on TSD 100 cm) in 4 MeV electron beam energy. Actual collimated field size of 105 cmx105 cm at the distance of 300 cm could include entire hemibody. A patient was standing on step board with hands up and holding the pole to stabilize his/her positions for the six-dual fields technique. As a scatter-degrader, 0.5 cm of acrylic plate was inserted at 20 cm from the body surface on the electron beam path to induce ray scattering and to increase the skin dose. The Full Width at Half Maximum(FWHM) of dose profile was 130 cm in large field of 105x105 cm 2 . The width of 100±10% of the resultant dose from two adjacent fields which were separated at 25 cm from field edge for obtaining the dose uniformity was extended to 186 cm. The depth of maximum dose lies at 5 mm and the 80% depth dose lies between 7 and 8 mm for the degraded electron beam by using the 0.5 cm thickness of acrylic absorber. Total skin electron beam irradiation (TSEBI) was carried out using the six dual fields has been developed at Stanford University. The dose distribution in TSEBI showed relatively uniform around the flat region of skin except the protruding and deeply curvatured portion of the body, which showed excess of dose at the former and less dose at the latter. The percent depth dose, profile curves and superimposed dose distribution were investigated using the degraded using the degraded electron beam through the beam absorber. The dose distribution obtained by experiments of TSEBI showed within±10% difference excepts the protruding area of skin which needs a

  2. Dose rate and total dose dependence of the 1/f noise performance of a GaAs operational amplifier during irradiation

    International Nuclear Information System (INIS)

    Hiemstra, D.M.

    1995-01-01

    A pictorial of a sectioned view of the torus of the International Thermonuclear Experimental Reactor (ITER) is shown. Maintenance and inspection of the reactor are required to be performed remotely. This is due to the high gamma radiation environment in vessel during inspection and maintenance activities. The custom GaAs operational amplifier is to be used to readout sensors on the in-vessel manipulator and inspection equipment. The gamma dose rate during maintenance and inspection is anticipated to be 3 Mrad(GaAs)/hour. Here, dose rate and total dose dependence of the 1/f noise performance of a custom GaAs MESFET operational amplifier during irradiation are presented. Dose rate dependent 1/f noise degradation during irradiation is believed to be due to electron trapping in deep levels, enhanced by backgating and shallow traps excited during irradiation. The reduction of this affect with accumulated total dose is believed to be due a reduction of deep level site concentration associated with substitutional oxygen. Post irradiation 1/f noise degradation is also presented.The generation-recombination noise observed post irradiation can be attributed to the production of shallow traps due to ionizing radiation

  3. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  4. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  5. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  6. Safety aspects of preoperative high-dose glucocorticoid in primary total knee replacement

    DEFF Research Database (Denmark)

    Jørgensen, C C; Pitter, F T; Kehlet, H

    2017-01-01

    Background: Preoperative single high-dose glucocorticoid may have early outcome benefits in total hip arthroplasty (THA) and knee arthroplasty (TKA), but long-term safety aspects have not been evaluated. Methods: From October 2013, the departments reporting to the prospective Lundbeck Foundation....... Conclusions: In this detailed prospective cohort study, preoperative high-dose glucocorticoid administration was not associated with LOS >4 days, readmissions or infectious complications in TKA patients without contraindications....

  7. Enhancement of Transistor-to-Transistor Variability Due to Total Dose Effects in 65-nm MOSFETs

    CERN Document Server

    Gerardin, S; Cornale, D; Ding, L; Mattiazzo, S; Paccagnella, A; Faccio, F; Michelis, S

    2015-01-01

    We studied device-to-device variations as a function of total dose in MOSFETs, using specially designed test structures and procedures aimed at maximizing matching between transistors. Degradation in nMOSFETs is less severe than in pMOSFETs and does not show any clear increase in sample-to-sample variability due to the exposure. At doses smaller than 1 Mrad( SiO2) variability in pMOSFETs is also practically unaffected, whereas at very high doses-in excess of tens of Mrad( SiO2)-variability in the on-current is enhanced in a way not correlated to pre-rad variability. The phenomenon is likely due to the impact of random dopant fluctuations on total ionizing dose effects.

  8. Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    LaBel, Kenneth A.; OBryan, Martha V.; Chen, Dakai; Campola, Michael J.; Casey, Megan C.; Pellish, Jonathan A.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Topper, Alyson D.; Ladbury, Raymond L.; hide

    2014-01-01

    We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

  9. Design of spray dried insulin microparticles to bypass deposition in the extrathoracic region and maximize total lung dose.

    Science.gov (United States)

    Ung, Keith T; Rao, Nagaraja; Weers, Jeffry G; Huang, Daniel; Chan, Hak-Kim

    2016-09-25

    Inhaled drugs all too often deliver only a fraction of the emitted dose to the target lung site due to deposition in the extrathoracic region (i.e., mouth and throat), which can lead to increased variation in lung exposure, and in some instances increases in local and systemic side effects. For aerosol medications, improved targeting to the lungs may be achieved by tailoring the micromeritic properties of the particles (e.g., size, density, rugosity) to minimize deposition in the mouth-throat and maximize the total lung dose. This study evaluated a co-solvent spray drying approach to modulate particle morphology and dose delivery characteristics of engineered powder formulations of insulin microparticles. The binary co-solvent system studied included water as the primary solvent mixed with an organic co-solvent, e.g., ethanol. Factors such as the relative rate of evaporation of each component of a binary co-solvent mixture, and insulin solubility in each component were considered in selecting feedstock compositions. A water-ethanol co-solvent mixture with a composition range considered suitable for modulating particle shell formation during drying was selected for experimental investigation. An Alberta Idealized Throat model was used to evaluate the in vitro total lung dose of a series of spray dried insulin formulations engineered with different bulk powder properties and delivered with two prototype inhalers that fluidize and disperse powder using different principles. The in vitro total lung dose of insulin microparticles was improved and favored for powders with low bulk density and small primary particle size, with reduction of deposition in the extrathoracic region. The results demonstrated that a total lung dose >95% of the delivered dose can be achieved with engineered particles, indicating a high degree of lung targeting, almost completely bypassing deposition in the mouth-throat. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Intralesional Versus Oral Chloroquine in Cutaneous Leishmaniasis: Comparison of Outcome, Duration of Treatment and Total Dose of Drug

    International Nuclear Information System (INIS)

    Hanif, M. M.; Akram, K.; Mustafa, G.

    2016-01-01

    Objective: To compare intralesional versus oral chloroquine in cutaneous leishmaniasis and determine the cure rate, duration of treatment, and total dose of drug. Study Design: Randomized controlled study. Place and Duration of Study: Department of Dermatology, Sheikh Zayed Medical College/Hospital, Rahim Yar Khan, from November 2013 to June 2014. Methodology: Consecutive 86 patients of cutaneous leishmaniasis, with single to multiple lesions of various sizes were enrolled and divided randomly into group A and B for the purpose of intralesional and oral chloroquine administration, respectively to compare the effect of the two routes on duration of treatment and total dose of the drug. SPSS version 16 was used for data analysis after data entry into it. Quantitative variables like, duration, cost and total dose of treatment were calculated as mean and standard deviation and compared by using T-test. P-value of less than 0.05 was taken as significant. Results: Cure rate was 100% in both groups towards the end of treatment. Mean duration of treatment was 9.17 ± 3 weeks in intralesional (A) group as against 11.37 ± 3 weeks in oral (B) group (p = 0.0028). Mean total dose of the drug given to each patient in group A was 5.8 ± 0.5 gm and in group B, it was 19.2 ± 1.5 gm, which is significantly higher (p=0.001). The total cost of treatment in group A was Rs. 90 ± 8 and in group B it was Rs. 91 ± 1 (p=0.446). Conclusion: Duration of treatment is significantly shorter and total dose is lesser with intralesional compared to oral chloroquine in treatment of cutaneous leishmaniasis. (author)

  11. Central axis dose verification in patients treated with total body irradiation of photons using a Computed Radiography system

    International Nuclear Information System (INIS)

    Rubio Rivero, A.; Caballero Pinelo, R.; Gonzalez Perez, Y.

    2015-01-01

    To propose and evaluate a method for the central axis dose verification in patients treated with total body irradiation (TBI) of photons using images obtained through a Computed Radiography (CR) system. It was used the Computed Radiography (Fuji) portal imaging cassette readings and correlate with measured of absorbed dose in water using 10 x 10 irradiation fields with ionization chamber in the 60 Co equipment. The analytical and graphic expression is obtained through software 'Origin8', the TBI patient portal verification images were processed using software ImageJ, to obtain the patient dose. To validate the results, the absorbed dose in RW3 models was measured with ionization chamber with different thickness, simulating TBI real conditions. Finally it was performed a retrospective study over the last 4 years obtaining the patients absorbed dose based on the reading in the image and comparing with the planned dose. The analytical equation obtained permits estimate the absorbed dose using image pixel value and the dose measured with ionization chamber and correlated with patient clinical records. Those results are compared with reported evidence obtaining a difference less than 02%, the 3 methods were compared and the results are within 10%. (Author)

  12. Dose-escalated total body irradiation and autologous stem cell transplantation for refractory hematologic malignancy

    International Nuclear Information System (INIS)

    McAfee, Steven L.; Powell, Simon N.; Colby, Christine; Spitzer, Thomas R.

    2002-01-01

    Purpose: To evaluate the feasibility of dose escalation of total body irradiation (TBI) above the previously reported maximally tolerated dose, we have undertaken a Phase I-II trial of dose-escalated TBI with autologous peripheral blood stem cell transplantation (PBSCT) for chemotherapy-refractory lymphoma. Methods and Materials: Nine lymphoma patients with primary refractory disease (PRD) or in resistant relapse (RR) received dose-escalated TBI and PBSCT. The three dose levels of fractionated TBI (200 cGy twice daily) were 1,600 cGy, 1,800 cGy, and 2,000 cGy. Lung blocks were used to reduce the TBI transmission dose by 50%, and the chest wall dose was supplemented to the prescribed dose using electrons. Shielding of the kidneys was performed to keep the maximal renal dose at 1,600 cGy. Three patients, two with non-Hodgkin's lymphoma (NHL) in RR and one with PRD Hodgkin's disease, received 1,600 cGy + PBSCT, three patients (two NHL in RR, one PRD) received 1,800 cGy + PBSCT, and three patients with NHL (two in RR, one PRD) received 2,000 cGy + PBSCT. Results: Toxicities associated with this high-dose TBI regimen included reversible hepatic veno-occlusive disease in 1 patient, Grade 2 mucositis requiring narcotic analgesics in 8 patients, and neurologic toxicities consisting of a symmetrical sensory neuropathy (n=4) and Lhermitte's syndrome (n=1). Interstitial pneumonitis developed in 1 patient who received 1,800 cGy after receiving recombinant α-interferon (with exacerbation after rechallenge with interferon). Six (66%) patients achieved a response. Four (44%) patients achieved complete responses, three of which were of a duration greater than 1 year, and 2 (22%) patients achieved a partial response. One patient remains disease-free more than 5 years posttransplant. Corticosteroid-induced gastritis and postoperative infection resulted in the death of 1 patient in complete response, 429 days posttransplant. Conclusion: TBI in a dose range 1,600-2,000 cGy as

  13. A prospective, open-label study of low-dose total skin electron beam therapy in mycosis fungoides

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Specht, Lena; Skovgaard, Gunhild L

    2008-01-01

    causes and did not complete treatment. Acute side effects included desquamation, xerosis, and erythema of the skin. No severe side effects were observed. CONCLUSION: Low-dose total skin electron beam therapy can induce complete and partial responses in Stage IB-II mycosis fungoides; however, the duration......PURPOSE: To determine the effect of low-dose (4 Gy) total skin electron beam therapy as a second-line treatment of Stage IB-II mycosis fungoides in a prospective, open-label study. METHODS AND MATERIALS: Ten patients (6 men, 4 women, average age 68.7 years [range, 55-82 years......]) with histopathologically confirmed mycosis fungoides T2-T4 N0-N1 M0 who did not achieve complete remission or relapsed within 4 months after treatment with psoralen plus ultraviolet-A were included. Treatment consisted of low-dose total skin electron beam therapy administered at a total skin dose of 4 Gy given in 4...

  14. Total dose induced latch in short channel NMOS/SOI transistors

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Quoizola, S.; Musseau, O.; Flament, O.; Leray, J.L.; Pelloie, J.L.; Raynaud, C.; Faynot, O.

    1998-01-01

    A latch effect induced by total dose irradiation is observed in short channel SOI transistors. This effect appears on NMOS transistors with either a fully or a partially depleted structure. It is characterized by a hysteresis behavior of the Id-Vg characteristics at high drain bias for a given critical dose. Above this dose, the authors still observe a limited leakage current at low drain bias (0.1 V), but a high conduction current at high drain bias (2 V) as the transistor should be in the off-state. The critical dose above which the latch appears strongly depends on gate length, transistor structure (fully or partially depleted), buried oxide thickness and supply voltage. Two-dimensional (2D) numerical simulations indicate that the parasitic condition is due to the latch of the back gate transistor triggered by charge trapping in the buried oxide. To avoid the latch induced by the floating body effect, different techniques can be used: doping engineering, body contacts, etc. The study of the main parameters influencing the latch (gate length, supply voltage) shows that the scaling of technologies does not necessarily imply an increased latch sensitivity. Some technological parameters like the buried oxide hardness and thickness can be used to avoid latch, even at high cumulated dose, on highly integrated SOI technologies

  15. Total Ionizing Dose Effects on Threshold Switching in 1T-Tantalum Disulfide Charge-Density-Wave Devices

    OpenAIRE

    Liu, G.; Zhang, E. X.; Liang, C. D.; Bloodgood, M. A.; Salguero, T. T.; Fleetwood, D. M.; Balandin, A. A.

    2017-01-01

    The 1T polytype of TaS2 exhibits voltage-triggered threshold switching as a result of a phase transition from nearly commensurate to incommensurate charge density wave states. Threshold switching, persistent above room temperature, can be utilized in a variety of electronic devices, e.g., voltage controlled oscillators. We evaluated the total-ionizing-dose response of thin film 1T-TaS2 at doses up to 1 Mrad(SiO2). The threshold voltage changed by less than 2% after irradiation, with persisten...

  16. Statistical analysis of dose heterogeneity in circulating blood: implications for sequential methods of total body irradiation.

    Science.gov (United States)

    Molloy, Janelle A

    2010-11-01

    Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these "sequential" techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than +/- 10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was

  17. Low-dose total skin electron beam therapy for cutaneous lymphoma : Minimal risk of acute toxicities.

    Science.gov (United States)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor

    2017-12-01

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T‑cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses.

  18. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    International Nuclear Information System (INIS)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu

    2001-01-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52±15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m 2 or higher were assigned to the high dose group and those given doses under 300 mg/m 2 to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3±218.2 mg/m 2 . In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m 2 appeared to be the borderline dose beyond which there were

  19. Clinical study on the adriamycin induced cardiomyopathy using the cardiac magnetic resonance imaging. Total dose and cardiac dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Kyoko; Teraoka, Kunihiko; Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    2001-05-01

    We studied cardiac functional disorders caused by Adoriamycin using gadolinium (Gd) contrast cine MRI. Forty-eight patients were given ACT (31 men and 17 women; mean age, 52{+-}15 years). First, the relationship between dose and the left ventricular volume, cardiac function, left ventricular cardiac mass and localized wall motion were examined in all patients. Patients given a total dose of 300 mg/m{sup 2} or higher were assigned to the high dose group and those given doses under 300 mg/m{sup 2} to the low dose group. The same parameters were studied in both groups and compared. A 1.5-Tesla superconductive MRI was used for all studies. Cine images of the long and short axes at the papillary muscle level were obtained by ECG R-wave synchronized Gd contrast cine MRI. Left ventricular volume and cardiac function were analyzed using the long-axis cine images and the wall thickness in diastole and systole was measured at each site using the short-axis cine images. The percentage of wall thickness was calculated at each site. The mean ACT dose was 273.3{+-}218.2 mg/m{sup 2}. In all patients the total dose directly correlated with ESVI and inversely correlated with the ejection fraction (EF). In the high dose group, the total dose and EF were inversely correlated, but no significant differences were observed in the low dose group. In the high dose group, the ESVI was significantly greater and the SVI and EF were more significantly reduced than in the low dose group. In the high dose group, the thickness of the anterior, lateral and posterior walls, excluding the septum, was significantly lower than in the low dose group. However, changes in wall thickness were not significantly different between the groups. Gd contrast cine MRI was useful in examining cardiac functional disorders caused by anthracyclines. The total dose of anthracycline correlated directly with the ESVI, and inversely with the EF. A total dose of 300 mg/m{sup 2} appeared to be the borderline dose beyond

  20. Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

    International Nuclear Information System (INIS)

    Martin, K.E.; Gauthier, M.K.; Coss, J.R.; Dantas, A.R.V.; Price, W.E.

    1986-05-01

    Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose

  1. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  2. The biological effects of high dose total body irradiation in beagle dogs

    International Nuclear Information System (INIS)

    Luo Qingliang; Liu Xiaolan; Hao Jing; Xiong Guolin; Dong Bo; Zhao Zhenhu; Xia Zhengbiao; Qiu Liling; Mao Bingzhi

    2002-01-01

    Objective: To evaluate the biological effects of Beagle dogs irradiated by γ-rays at different doses. Methods: All Beagle dogs were divided into six groups and were subjected respectively to total-body irradiation (TBI) with a single dose of 6.5, 5.5, 5.0, 4.5, 3, 5 and 2.5 Gy γ-rays delivered by 60 Co sources at 7.224 x 10 -2 C/kg per minute. The general condition, blood cell counts and bone marrow cell CFC assays were observed. Results: Vomiting occurred at 0.5 to 2 hours after TBI in all groups. In 6.5 Gy group 3/5 dogs had blood-watery stool and 1/5 in 5.5 Gy group had watery stool. Diarrhea occurred in all other animals. Only one dog in 2.5 Gy group survived, all of others died. in order of decreasing irradiation dosage, the average survival time was 5.0, 8.0, 9.3, 9.5, 10.5 and 14.1 days, respectively. Conclusions: According to the clinical symptoms, leukocyte count and survival time of the dogs, the irradiation dose which will induce very severe hematopoietic radiation syndrome in Beagle dogs is 4.5 to 5.0 Gy

  3. The Role of Electron Transport and Trapping in MOS Total-Dose Modeling

    International Nuclear Information System (INIS)

    Flament, O.; Fleetwood, D.M.; Leray, J.L.; Paillet, P.; Riewe, L.C.; Winokur, P.S.

    1999-01-01

    Deep and shallow electron traps form in irradiated thermal SiO 2 as a natural response to hole transport and trapping. The density and stability of these defects are discussed, as are their implications for total-dose modeling

  4. Use of an electron reflector to improve dose uniformity at the vertex during total skin electron therapy

    International Nuclear Information System (INIS)

    Peters, V.G.

    2000-01-01

    Purpose: The vertex of the scalp is always tangentially irradiated during total skin electron therapy (TSET). This study was conducted to determine the dose distribution at the vertex for a commonly used irradiation technique and to evaluate the use of an electron reflector, positioned above the head, as a means of improving the dose uniformity. Methods and Materials: Phantoms, simulating the head of a patient, were irradiated using our standard procedure for TSET. The technique is a six-field irradiation using dual angled electron beams at a treatment distance of 3.6 meters. Vertex dosimetry was performed using ionization methods and film. Measurements were made for an unmodified 6 MeV electron beam and for a 4 MeV beam obtained by placing an acrylic scattering plate in the beam line. Studies were performed to examine the effect of electron scattering on vertex dose when a lead reflector, 50 x 50 cm in area, was positioned above the phantom. Results: The surface dose at the vertex, in the absence of the reflector, was found to be less than 40% of the prescribed skin dose. Use of the lead reflector increased this value to 73% for the 6 MeV beam and 99% for the degraded 4 MeV beam. Significant improvements in depth dose were also observed. The dose enhancement is not strongly dependent on reflector distance or angulation since the reflector acts as a large source of broadly scattered electrons. Conclusion: The vertex may be significantly underdosed using standard techniques for total skin electron therapy. Use of an electron reflector improves the dose uniformity at the vertex and may reduce or eliminate the need for supplemental irradiation

  5. A first-principles approach to total-dose hardness assurance

    International Nuclear Information System (INIS)

    Fleetwood, D.M.

    1995-01-01

    A first-principles approach to radiation hardness assurance was described that provides the technical background to the present US and European total-dose radiation hardness assurance test methods for MOS technologies, TM 1019.4 and BS 22900. These test methods could not have been developed otherwise, as their existence depends not on a wealth of empirical comparisons of IC data from ground and space testing, but on a fundamental understanding of MOS defect growth and annealing processes. Rebound testing should become less of a problem for advanced MOS small-signal electronics technologies for systems with total dose requirements below 50--100 krad(SiO 2 ) because of trends toward much thinner gate oxides. For older technologies with thicker gate oxides and for power devices, rebound testing is unavoidable without detailed characterization studies to assess the impact of interface traps on devices response in space. The QML approach is promising for future hardened technologies. A sufficient understanding of process effects on radiation hardness has been developed that should be able to reduce testing costs in the future for hardened parts. Finally, it is hoped that the above discussions have demonstrated that the foundation for cost-effective hardness assurance tests is laid with studies of the basic mechanisms of radiation effects. Without a diligent assessment of new radiation effects mechanisms in future technologies, one cannot be assured that the present generation of radiation test standards will continue to apply

  6. Inclusion of Radiation Environment Variability in Total Dose Hardness Assurance Methodology

    Science.gov (United States)

    Xapsos, M. A.; Stauffer, C.; Phan, A.; McClure, S. S.; Ladbury, R. L.; Pellish, J. A.; Campola, M. J.; LaBel, K. A.

    2016-01-01

    Variability of the space radiation environment is investigated with regard to parts categorization for total dose hardness assurance methods. It is shown that it can have a significant impact. A modified approach is developed that uses current environment models more consistently and replaces the radiation design margin concept with one of failure probability during a mission.

  7. Long term results of a prospective dose escalation phase-II trial: Interstitial pulsed-dose-rate brachytherapy as boost for intermediate- and high-risk prostate cancer

    International Nuclear Information System (INIS)

    Lettmaier, Sebastian; Lotter, Michael; Kreppner, Stephan; Strnad, Annedore; Fietkau, Rainer; Strnad, Vratislav

    2012-01-01

    Purpose: We reviewed our seven year single institution experience with pulsed dose rate brachytherapy dose escalation study in patients with intermediate and high risk prostate cancer. Materials and methods: We treated a total of 130 patients for intermediate and high risk prostate cancer at our institution between 2000 and 2007 using PDR-brachytherapy as a boost after conformal external beam radiation therapy to 50.4 Gy. The majority of patients had T2 disease (T1c 6%, T2 75%, T3 19%). Seventy three patients had intermediate-risk and 53 patients had high-risk disease according to the D’Amico classification. The dose of the brachytherapy boost was escalated from 25 to 35 Gy – 33 pts. received 25 Gy (total dose 75 Gy), 63 pts. 30 Gy (total dose 80 Gy) and 34 pts. 35 Gy, (total dose 85 Gy) given in one session (dose per pulse was 0.60 Gy or 0.70 Gy/h, 24 h per day, night and day, with a time interval of 1 h between two pulses). PSA-recurrence-free survival according to Kaplan–Meier using the Phoenix definition of biochemical failure was calculated and also late toxicities according to Common Toxicity Criteria scale were assessed. Results: At the time of analysis with a median follow-up of 60 months biochemical control was achieved by 88% of patients – only 16/130 patients (12.3%) developed a biochemical relapse. Biochemical relapse free survival calculated according to Kaplan–Meier for all patients at 5 years was 85.6% (83.9% for intermediate-risk patients and 84.2% for high-risk patients) and at 9 years’ follow up it was 79.0%. Analysing biochemical relapse free survival separately for different boost dose levels, at 5 years it was 97% for the 35 Gy boost dose and 82% for the 25 and 30 Gy dose levels. The side effects of therapy were negligible: There were 18 cases (15%) of grade 1/2 rectal proctitis, one case (0.8%) of grade 3 proctitis, 18 cases (15%) of grade 1/2 cystitis, and no cases (0%) with dysuria grade 3. No patient had a bulbourethral

  8. Emesis as a Screening Diagnostic for Low Dose Rate (LDR) Total Body Radiation Exposure.

    Science.gov (United States)

    Camarata, Andrew S; Switchenko, Jeffrey M; Demidenko, Eugene; Flood, Ann B; Swartz, Harold M; Ali, Arif N

    2016-04-01

    Current radiation disaster manuals list the time-to-emesis (TE) as the key triage indicator of radiation dose. The data used to support TE recommendations were derived primarily from nearly instantaneous, high dose-rate exposures as part of variable condition accident databases. To date, there has not been a systematic differentiation between triage dose estimates associated with high and low dose rate (LDR) exposures, even though it is likely that after a nuclear detonation or radiologic disaster, many surviving casualties would have received a significant portion of their total exposure from fallout (LDR exposure) rather than from the initial nuclear detonation or criticality event (high dose rate exposure). This commentary discusses the issues surrounding the use of emesis as a screening diagnostic for radiation dose after LDR exposure. As part of this discussion, previously published clinical data on emesis after LDR total body irradiation (TBI) is statistically re-analyzed as an illustration of the complexity of the issue and confounding factors. This previously published data includes 107 patients who underwent TBI up to 10.5 Gy in a single fraction delivered over several hours at 0.02 to 0.04 Gy min. Estimates based on these data for the sensitivity of emesis as a screening diagnostic for the low dose rate radiation exposure range from 57.1% to 76.6%, and the estimates for specificity range from 87.5% to 99.4%. Though the original data contain multiple confounding factors, the evidence regarding sensitivity suggests that emesis appears to be quite poor as a medical screening diagnostic for LDR exposures.

  9. Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation

    International Nuclear Information System (INIS)

    Choi, Jong Hwan; Kim, Jong Sik; Choi, Ji Min; Shin, Eun Hyuk; Song, Ki Won; Park, Young Hwan

    2007-01-01

    Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = 40 x 40 cm 2 . The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is 14.58-14.92 cGy. Therefore, The surface dose was measured 99.4-101% with got near most to the prescription dose. In clinical case, distance between beam spoiler and patient affect surface dose. If once 50-60 cm of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  10. Low Dose Gamma Irradiation Does Not Affect the Quality or Total Ascorbic Acid Concentration of "Sweetheart" Passionfruit (Passiflora edulis).

    Science.gov (United States)

    Golding, John B; Blades, Barbara L; Satyan, Shashirekha; Spohr, Lorraine J; Harris, Anne; Jessup, Andrew J; Archer, John R; Davies, Justin B; Banos, Connie

    2015-08-26

    Passionfruit ( Passiflora edulis , Sims, cultivar "Sweetheart") were subject to gamma irradiation at levels suitable for phytosanitary purposes (0, 150, 400 and 1000 Gy) then stored at 8 °C and assessed for fruit quality and total ascorbic acid concentration after one and fourteen days. Irradiation at any dose (≤1000 Gy) did not affect passionfruit quality (overall fruit quality, colour, firmness, fruit shrivel, stem condition, weight loss, total soluble solids level (TSS), titratable acidity (TA) level, TSS/TA ratio, juice pH and rot development), nor the total ascorbic acid concentration. The length of time in storage affected some fruit quality parameters and total ascorbic acid concentration, with longer storage periods resulting in lower quality fruit and lower total ascorbic acid concentration, irrespective of irradiation. There was no interaction between irradiation treatment and storage time, indicating that irradiation did not influence the effect of storage on passionfruit quality. The results showed that the application of 150, 400 and 1000 Gy gamma irradiation to "Sweetheart" purple passionfruit did not produce any deleterious effects on fruit quality or total ascorbic acid concentration during cold storage, thus supporting the use of low dose irradiation as a phytosanitary treatment against quarantine pests in purple passionfruit.

  11. Total dose hardening of buried insulator in implanted silicon-on-insulator structures

    International Nuclear Information System (INIS)

    Mao, B.Y.; Chen, C.E.; Pollack, G.; Hughes, H.L.; Davis, G.E.

    1987-01-01

    Total dose characteristics of the buried insulator in implanted silicon-on-insulator (SOI) substrates have been studied using MOS transistors. The threshold voltage shift of the parasitic back channel transistor, which is controlled by charge trapping in the buried insulator, is reduced by lowering the oxygen dose as well as by an additional nitrogen implant, without degrading the front channel transistor characteristics. The improvements in the radiation characteristics of the buried insulator are attributed to the decrease in the buried oxide thickness or to the presence of the interfacial oxynitride layer formed by the oxygen and nitrogen implants

  12. In pediatric leukemia, dose evaluation according to the type of compensators in total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yeon [Dongnam Inst. of Radiological and Medical science, Busan (Korea, Republic of); Kim, Chang Soo; Kim, Jung Hoon [Dept. of Radiological Science, College of Health Science, Catholic University of Busan, Busan (Korea, Republic of)

    2015-04-15

    Total body irradiation (TBI) and chemotherapy are the pre-treatment method of a stem cell transplantations of the childhood leukemia. in this study, we evaluate the Quantitative human body dose prior to the treatment. The MCNPX simulation program evaluated by changing the material of the tissue compensators with imitation material of pediatric exposure in a virtual space. As a result, first, the average skin dose with the material of the tissue compensators of Plexiglass tissue compensators is 74.60 mGy/min, Al is 73.96 mGy/min, Cu is 72.26 mGy/min and Pb 67.90 mGy/min respectively. Second, regardless of the tissue compensators material that organ dose were thyroid, gentile, digestive system, brain, lungs, kidneys higher in order. Finally, the ideal distance between body compensator and the patient were 50 cm aparting each other. In conclusion, tissue compensators Al, Cu, Pb are able to replace of the currently used in Plexiglass materials.

  13. An improved standard total dose test for CMOS space electronics

    International Nuclear Information System (INIS)

    Fleetwood, D.M.; Winokur, P.S.; Riewe, L.C.; Pease, R.L.

    1989-01-01

    The postirradiation response of hardened and commercial CMOS devices is investigated as a function of total dose, dose rate, and annealing time and temperature. Cobalt-60 irradiation at ≅ 200 rad(SiO 2 )/s followed by a 1-week 100 degrees C biased anneal and testing is shown to be an effective screen of hardened devices for space use. However, a similar screen and single-point test performed after Co-60 irradiation and elevated temperature anneal cannot be generally defined for commercial devices. In the absence of detailed knowledge about device and circuit radiation response, a two-point standard test is proposed to ensure space surviability of CMOS circuits: a Co-60 irradiation and test to screen against oxide-trapped charge related failures, and an additional rebound test to screen against interface-trap related failures. Testing implications for bipolar technologies are also discussed

  14. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  15. Compendium of Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.; hide

    2012-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.

  16. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  17. Time- and dose-dependent effects of total-body ionizing radiation on muscle stem cells

    Science.gov (United States)

    Masuda, Shinya; Hisamatsu, Tsubasa; Seko, Daiki; Urata, Yoshishige; Goto, Shinji; Li, Tao-Sheng; Ono, Yusuke

    2015-01-01

    Exposure to high levels of genotoxic stress, such as high-dose ionizing radiation, increases both cancer and noncancer risks. However, it remains debatable whether low-dose ionizing radiation reduces cellular function, or rather induces hormetic health benefits. Here, we investigated the effects of total-body γ-ray radiation on muscle stem cells, called satellite cells. Adult C57BL/6 mice were exposed to γ-radiation at low- to high-dose rates (low, 2 or 10 mGy/day; moderate, 50 mGy/day; high, 250 mGy/day) for 30 days. No hormetic responses in proliferation, differentiation, or self-renewal of satellite cells were observed in low-dose radiation-exposed mice at the acute phase. However, at the chronic phase, population expansion of satellite cell-derived progeny was slightly decreased in mice exposed to low-dose radiation. Taken together, low-dose ionizing irradiation may suppress satellite cell function, rather than induce hormetic health benefits, in skeletal muscle in adult mice. PMID:25869487

  18. Origins of Total-Dose Response Variability in Linear Bipolar Microcircuits

    International Nuclear Information System (INIS)

    Barnaby, H.J.; Cirba, C.R.; Schrimpf, R.D.; Fleetwood, D.M.; Pease, R.L.; Shaneyfelt, Marty R.; Turflinger, T.; Krieg, J.F.; Maher, M.C.

    2000-01-01

    LM1ll voltage comparators exhibit a wide range of total-dose-induced degradation. Simulations show this variability may be a natural consequence of the low base doping of the substrate PNP (SPNP) input transistors. Low base doping increases the SPNP's collector to base breakdown voltage, current gain, and sensitivity to small fluctuations in the radiation-induced oxide defect densities. The build-up of oxide trapped charge (N ot ) and interface traps (N it ) is shown to be a function of pre-irradiation bakes. Experimental data indicate that, despite its structural similarities to the LM111, irradiated input transistors of the LM124 operational amplifier do not exhibit the same sensitivity to variations in pre-irradiation thermal cycles. Further disparities in LM111 and LM124 responses may result from a difference in the oxide defect build-up in the two part types. Variations in processing, packaging, and circuit effects are suggested as potential explanations

  19. Fast method for in-flight estimation of total dose from protons and electrons using RADE Minstrument on JUICE

    Science.gov (United States)

    Hajdas, Wojtek; Mrigakshi, Alankrita; Xiao, Hualin

    2017-04-01

    The primary concern of the ESA JUICE mission to Jupiter is the harsh particle radiation environment. Ionizing particles introduce radiation damage by total dose effects, displacement damages or single events effects. Therefore, both the total ionizing dose and the displacement damage equivalent fluence must be assessed to alert spacecraft and its payload as well as to quantify radiation levels for the entire mission lifetime. We present a concept and implementations steps for simplified method used to compute in flight a dose rate and total dose caused by protons. We also provide refinement of the method previously developed for electrons. The dose rates values are given for predefined active volumes located behind layers of materials with known thickness. Both methods are based on the electron and proton flux measurements provided by the Electron and Proton Detectors inside the Radiation Hard Electron Monitor (RADEM) located on-board of JUICE. The trade-off between method accuracy and programming limitations for in-flight computations are discussed. More comprehensive and precise dose rate computations based on detailed analysis of all stack detectors will be made during off-line data processing. It will utilize full spectral unfolding from all RADEM detector subsystems.

  20. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  1. Total Ambient Dose Equivalent Buildup Factor Determination for Nbs04 Concrete.

    Science.gov (United States)

    Duckic, Paulina; Hayes, Robert B

    2018-06-01

    Buildup factors are dimensionless multiplicative factors required by the point kernel method to account for scattered radiation through a shielding material. The accuracy of the point kernel method is strongly affected by the correspondence of analyzed parameters to experimental configurations, which is attempted to be simplified here. The point kernel method has not been found to have widespread practical use for neutron shielding calculations due to the complex neutron transport behavior through shielding materials (i.e. the variety of interaction mechanisms that neutrons may undergo while traversing the shield) as well as non-linear neutron total cross section energy dependence. In this work, total ambient dose buildup factors for NBS04 concrete are calculated in terms of neutron and secondary gamma ray transmission factors. The neutron and secondary gamma ray transmission factors are calculated using MCNP6™ code with updated cross sections. Both transmission factors and buildup factors are given in a tabulated form. Practical use of neutron transmission and buildup factors warrants rigorously calculated results with all associated uncertainties. In this work, sensitivity analysis of neutron transmission factors and total buildup factors with varying water content has been conducted. The analysis showed significant impact of varying water content in concrete on both neutron transmission factors and total buildup factors. Finally, support vector regression, a machine learning technique, has been engaged to make a model based on the calculated data for calculation of the buildup factors. The developed model can predict most of the data with 20% relative error.

  2. Dose-effect relationship for cataract induction after single-dose total body irradiation and bone marrow transplantation for acute leukemia

    International Nuclear Information System (INIS)

    Kempen-Harteveld, M. Loes van; Belkacemi, Yazid; Kal, Henk B.; Labopin, Myriam; Frassoni, Francesco

    2002-01-01

    Purpose: To determine a dose-effect relationship for cataract induction, the tissue-specific parameter, α/β, and the rate of repair of sublethal damage, μ value, in the linear-quadratic formula have to be known. To obtain these parameters for the human eye lens, a large series of patients treated with different doses and dose rates is required. The data of patients with acute leukemia treated with single-dose total body irradiation (STBI) and bone marrow transplantation (BMT) collected by the European Group for Blood and Marrow Transplantation were analyzed. Methods and Materials: The data of 495 patients who underwent BMT for acute leukemia, who had STBI as part of their conditioning regimen, were analyzed using the linear-quadratic concept. The end point was the incidence of cataract formation after BMT. Of the analyzed patients, 175 were registered as having cataracts. Biologic effective doses (BEDs) for different sets of values for α/β and μ were calculated for each patient. With Cox regression analysis, using the overall chi-square test as the parameter evaluating the goodness of fit, α/β and μ values were found. Risk factors for cataract induction were the BED of the applied TBI regimen, allogeneic BMT, steroid therapy for >14 weeks, and heparin administration. To avoid the influence of steroid therapy and heparin on cataract induction, patients who received steroid or heparin treatment were excluded, leaving only the BED as a risk factor. Next, the most likely set of α/β and μ values was obtained. With this set, the cataract-free survival rates were calculated for specific BED intervals, according to the Kaplan-Meier method. From these calculations, cataract incidences were obtained as function of the BED at 120 months after STBI. Results: The use of BED instead of the TBI dose enabled the incidence of cataract formation to be predicted in a reasonably consistent way. With Cox regression analysis for all STBI data, a maximal chi-square value was

  3. Fractionated total body irradiation and autologous bone marrow transplantation in dogs: Hemopoietic recovery after various marrow cell doses

    International Nuclear Information System (INIS)

    Bodenburger, U.; Kolb, H.J.; Thierfelder, S.; Netzel, B.; Schaeffer, E.; Kolb, H.

    1980-01-01

    Hemopoietic recovery was studied in dogs given 2400 R fractionated total body irradiation within one week and graded doses of cryopreserved autologous bone marrow. Complete hemopoietic recovery including histology was observed after this dose and sufficient doses of marrow cells. Doses of more than 5.5 x 10 7 mononuclear marrow cells/kg body weight were sufficient for complete recovery in all dogs, 1.5 to 5.5 x 10 7 cells/kg were effective in some of the dogs and less than 1.5 x 10 7 cells/kg were insufficient for complete recovery. Similarly, more than 30000 CFUsub(c)/kg body weight were required for hemopoietic recovery. The optimal marrow cell dose which has been defined as the minimal dose required for the earliest possible recovery of leukocyte and platelet counts was 7-8 x 10 7 mononuclear marrow cells/kg body weight. It has been concluded that fractionated total body irradiation with 2400 R dose not require greater doses of marrow cells for hemopoietic reconstitution than lower single doses and that the hemopoietic microenvironment is not persistently disturbed after this dose. (author)

  4. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  5. Total ionizing dose radiation hardness of the ATLAS MDT-ASD and the HP-Agilent 0.5 um CMOS process

    CERN Document Server

    Posch, C

    2002-01-01

    A total ionizing dose (TID) test of the MDT-ASD, the ATLAS MDT front-end chip has been performed at the Harvard Cyclotron Lab. The MDT-ASD is an 8-channel drift tube read-out ASIC fabricated in a commercial 0.5 um CMOS process (AMOS14TB). The accumulated TID at the end of the test was 300 krad, delivered by 160 MeV protons at a rate of approximately 70 rad/sec. All 10 irradiated chips retained their full functionality and performance and showed only irrelevantly small changes in device parameters. As the total accumulated dose is substantially higher than the relevant ATLAS Radiation Tolerance Criteria (RTCtid), the results of this test indicate that MDT-ASD meets the ATLAS TID radiation hardness requirements. In addition, the results of this test correspond well with results of a 30 keV gamma TID irradiation test performed by us on an earlier prototype at the CERN x-ray facility as well as with results of other irradiation test on this process found in literature.

  6. In vivo dosimetry with semiconducting diodes for dose verification in total-body irradiation. A 10-year experience

    International Nuclear Information System (INIS)

    Ramm, U.; Licher, J.; Moog, J.; Scherf, C.; Kara, E.; Boettcher, H.D.; Roedel, C.; Mose, S.

    2008-01-01

    Background and purpose: for total-body irradiation (TBI) using the translation method, dose distribution cannot be computed with computer-assisted three-dimensional planning systems. Therefore, dose distribution has to be primarily estimated based on CT scans (beam-zone method) which is followed by in vivo measurements to ascertain a homogeneous dose delivery. The aim of this study was to clinically establish semiconductor probes as a simple and fast method to obtain an online verification of the dose at relevant points. Patients and methods: in 110 consecutively irradiated TBI patients (12.6 Gy, 2 x 1.8 Gy/day), six semiconductor probes were attached to the body surface at dose-relevant points (eye/head, neck, lung, navel). The mid-body point of the abdomen was defined as dose reference point. The speed of translation was optimized to definitively reach the prescribed dose in this point. Based on the entrance and exit doses, the mid-body doses at the other points were computed. The dose homogeneity in the entire target volume was determined comparing all measured data with the dose at the reference point. Results: after calibration of the semiconductor probes under treatment conditions the dose in selected points and the dose homogeneity in the target volume could be quantitatively specified. In the TBI patients, conformity of calculated and measured doses in the given points was achieved with small deviations of adequate accuracy. The data of 80% of the patients are within an uncertainty of ± 5%. Conclusion: during TBI using the translation method, dose distribution and dose homogeneity can be easily controlled in selected points by means of semiconductor probes. Semiconductor probes are recommended for further use in the physical evaluation of TBI. (orig.)

  7. Impact of radiation technique, radiation fraction dose, and total cisplatin dose on hearing. Retrospective analysis of 29 medulloblastoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Scobioala, Sergiu; Kittel, Christopher; Ebrahimi, Fatemeh; Wolters, Heidi; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiotherapy and Radiooncology, Muenster (Germany); Parfitt, Ross; Matulat, Peter; Am Zehnhoff-Dinnesen, Antoinette [University Hospital of Muenster, Department of Phoniatrics and Pediatric Audiology, Muenster (Germany)

    2017-11-15

    To analyze the incidence and degree of sensorineural hearing loss (SNHL) resulting from different radiation techniques, fractionation dose, mean cochlear radiation dose (D{sub mean}), and total cisplatin dose. In all, 29 children with medulloblastoma (58 ears) with subclinical pretreatment hearing thresholds participated. Radiotherapy (RT) and cisplatin had been applied sequentially according to the HIT MED Guidance. Audiological outcomes up to the latest follow-up (median 2.6 years) were compared. Bilateral high-frequency SNHL was observed in 26 patients (90%). No significant differences were found in mean hearing threshold between left and right ears at any frequency. A significantly better audiological outcome (p < 0.05) was found after tomotherapy at the 6 kHz bone-conduction threshold (BCT) and left-sided 8 kHz air-conduction threshold (ACT) than after a combined radiotherapy technique (CT). Fraction dose was not found to have any impact on the incidence, degree, and time-to-onset of SNHL. Patients treated with CT had a greater risk of SNHL at high frequencies than tomotherapy patients even though D{sub mean} was similar. Increase in severity of SNHL was seen when the total cisplatin dose reached above 210 mg/m{sup 2}, with the highest abnormal level found 8-12 months after RT regardless of radiation technique or fraction dose. The cochlear radiation dose should be kept as low as possible in patients who receive simultaneous cisplatin-based chemotherapy. The risk of clinically relevant HL was shown when D{sub mean} exceeds 45 Gy independent of radiation technique or radiation regime. Cisplatin ototoxicity was shown to have a dose-dependent effect on bilateral SNHL, which was more pronounced in higher frequencies. (orig.) [German] Analyse von Inzidenz und Schweregrad einer sensorineuralen Schwerhoerigkeit (''sensorineural hearing loss'', SNHL) infolge der Wirkung unterschiedlicher Bestrahlungstechniken, Fraktionierungen, mittlerer

  8. In vivo dosimetry for total body irradiation: five‐year results and technique comparison

    Science.gov (United States)

    Warry, Alison J.; Eaton, David J.; Collis, Christopher H.; Rosenberg, Ivan

    2014-01-01

    The aim of this work is to establish if the new CT‐based total body irradiation (TBI) planning techniques used at University College London Hospital (UCLH) and Royal Free Hospital (RFH) are comparable to the previous technique at the Middlesex Hospital (MXH) by analyzing predicted and measured diode results. TBI aims to deliver a homogeneous dose to the entire body, typically using extended SSD fields with beam modulation to limit doses to organs at risk. In vivo dosimetry is used to verify the accuracy of delivered doses. In 2005, when the Middlesex Hospital was decommissioned and merged with UCLH, both UCLH and the RFH introduced updated CT‐planned TBI techniques, based on the old MXH technique. More CT slices and in vivo measurement points were used by both; UCLH introduced a beam modulation technique using MLC segments, while RFH updated to a combination of lead compensators and bolus. Semiconductor diodes were used to measure entrance and exit doses in several anatomical locations along the entire body. Diode results from both centers for over five years of treatments were analyzed and compared to the previous MXH technique for accuracy and precision of delivered doses. The most stable location was the field center with standard deviations of 4.1% (MXH), 3.7% (UCLH), and 1.7% (RFH). The least stable position was the ankles. Mean variation with fraction number was within 1.5% for all three techniques. In vivo dosimetry can be used to verify complex modulated CT‐planned TBI, and demonstrate improvements and limitations in techniques. The results show that the new UCLH technique is no worse than the previous MXH one and comparable to the current RFH technique. PACS numbers: 87.55.Qr, 87.56.N‐ PMID:25207423

  9. Doses resulting from intrusion into uranium tailings areas

    International Nuclear Information System (INIS)

    Walsh, M.L.

    1986-02-01

    In the future, it is conceivable that institutional controls of uranium tailings areas may cease to exist and individuals may intrude into these areas unaware of the potential radiation hazards. The objective of this study was to estimate the potential doses to the intruders for a comprehensive set of intrusion scenarios. Reference tailings areas in the Elliot Lake region of northern Ontario and in northern Saskatchewan were developed to the extent required to calculate radiation exposures. The intrusion scenarios for which dose calculations were performed, were categorized into the following classes: habitation of the tailings, agricultural activities, construction activities, and recreational activities. Realistic exposure conditions were specified and annual doses were calculated by applying standard dose conversion factors. The exposure estimates demonstrated that the annual doses resulting from recreational activities and from construction activities would be generally small, less than twenty millisieverts, while the habitational and agricultural activities could hypothetically result in doses of several hundred millisieverts. However, the probability of occurrence of these latter classes of scenarios is considered to be much lower than scenarios involving either construction or recreational activities

  10. Preliminary results of measurement of natural environmental radiation levels and doses to population in China

    International Nuclear Information System (INIS)

    Wang Qiliang; He Miaoting; Shu Qi

    1985-01-01

    In this paper the preliminary results of measurement of natural environmental radiation levels in China with RSS-111 high pressure ionization chamber and estimated doses to population are reported. A total of 2,723 indoor locales throughout China were measured. The results showed that the average absorbed dose rates in air due to gamma radiation for indoors and outdoors were 11.0 x 10 -8 Gy.h -1 and 7.4 x 10 -8 Gy.h -1 , respectively, and those due to cosmic rays were 3.2 x 10 -8 Gy.h -1 and 3.7 x 10 -8 Gy.h -1 , respectively. The annual average effective dose equivalent to population was 919 μSv, including 630 μSv from natural gamma radiation and 289 μSv from cosmic rays

  11. Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone

    Energy Technology Data Exchange (ETDEWEB)

    Shipley, William U; Verhey, Lynn J; Munzenrider, John E; Suit, Herman D; Urie, Marcia M; McManus, Patricia L; Young, Robert H; Shipley, Jenot W; Zietman, Anthony L; Biggs, Peter J; Heney, Niall M; Goitein, Michael

    1995-04-30

    Purpose: Following a thorough Phase I/II study, we evaluated by a Phase III trial high versus conventional dose external beam irradiation as mono-therapy for patients with Stage T3-T4 prostate cancer. Patient outcome following standard dose radiotherapy or following a 12.5% increase in total dose to 75.6 Cobalt Gray Equivalent (CGE) using a conformal perineal proton boost was compared for local tumor control, disease-free survival, and overall survival. Methods and Materials: Stage T3-T4, Nx, N0-2, M0 patients received 50.4 Gy by four-field photons and were randomized to receive either an additional 25.2 CGE by conformal protons (arm 1--the high dose arm, 103 patients, total dose 75.6 CGE) or an additional 16.8 Gy by photons (arm 2--the conventional dose arm, 99 patients, total dose 67.2 Gy). Actuarial overall survival (OS), disease-specific survival (DSS), total recurrence-free survival (TRFS), (clinically free, prostate specific antigen (PSA) less than 4ng/ml and a negative prostate rebiopsy, done in 38 patients without evidence of disease) and local control (digital rectal exam and rebiopsy negative) were evaluated. Results: The protocol completion rate was 90% for arm 1 and 97% for arm 2. With a median follow-up of 61 months (range 3 to 139 months) 135 patients are alive and 67 have died, 20 from causes other than prostate cancer. We found no significant differences in OS, DSS, TRFS or local control between the two arms. Among those completing randomized treatment (93 in arm 1 and 96 in arm 2), the local control at 5 and 8 years for arm 1 is 92% and 77%, respectively and is 80% and 60%, respectively for arm 2 (p = .089) and there are no significant differences in OS, DSS, and TRFS. The local control for the 57 patients with poorly differentiated (Gleason 4 or 5 of 5) tumors at 5 and 8 years for arm 1 is 94% and 84% and is 64% and 19% on arm 2 (p 0.0014). In patients whose digital rectal exam had normalized following treatment and underwent prostate rebiopsy

  12. Advanced prostate cancer: the results of a randomized comparative trial of high dose irradiation boosting with conformal protons compared with conventional dose irradiation using photons alone

    International Nuclear Information System (INIS)

    Shipley, William U.; Verhey, Lynn J.; Munzenrider, John E.; Suit, Herman D.; Urie, Marcia M.; McManus, Patricia L.; Young, Robert H.; Shipley, Jenot W.; Zietman, Anthony L.; Biggs, Peter J.; Heney, Niall M.; Goitein, Michael

    1995-01-01

    Purpose: Following a thorough Phase I/II study, we evaluated by a Phase III trial high versus conventional dose external beam irradiation as mono-therapy for patients with Stage T3-T4 prostate cancer. Patient outcome following standard dose radiotherapy or following a 12.5% increase in total dose to 75.6 Cobalt Gray Equivalent (CGE) using a conformal perineal proton boost was compared for local tumor control, disease-free survival, and overall survival. Methods and Materials: Stage T3-T4, Nx, N0-2, M0 patients received 50.4 Gy by four-field photons and were randomized to receive either an additional 25.2 CGE by conformal protons (arm 1--the high dose arm, 103 patients, total dose 75.6 CGE) or an additional 16.8 Gy by photons (arm 2--the conventional dose arm, 99 patients, total dose 67.2 Gy). Actuarial overall survival (OS), disease-specific survival (DSS), total recurrence-free survival (TRFS), (clinically free, prostate specific antigen (PSA) less than 4ng/ml and a negative prostate rebiopsy, done in 38 patients without evidence of disease) and local control (digital rectal exam and rebiopsy negative) were evaluated. Results: The protocol completion rate was 90% for arm 1 and 97% for arm 2. With a median follow-up of 61 months (range 3 to 139 months) 135 patients are alive and 67 have died, 20 from causes other than prostate cancer. We found no significant differences in OS, DSS, TRFS or local control between the two arms. Among those completing randomized treatment (93 in arm 1 and 96 in arm 2), the local control at 5 and 8 years for arm 1 is 92% and 77%, respectively and is 80% and 60%, respectively for arm 2 (p = .089) and there are no significant differences in OS, DSS, and TRFS. The local control for the 57 patients with poorly differentiated (Gleason 4 or 5 of 5) tumors at 5 and 8 years for arm 1 is 94% and 84% and is 64% and 19% on arm 2 (p 0.0014). In patients whose digital rectal exam had normalized following treatment and underwent prostate rebiopsy

  13. New insights into fully-depleted SOI transistor response during total-dose irradiation

    International Nuclear Information System (INIS)

    Schwank, J.R.; Shaneyfelt, M.R.; Dodd, P.E.; Burns, J.A.; Keast, C.L.; Wyatt, P.W.

    1999-01-01

    In this paper, we present irradiation results on 2-fully depleted processes (HYSOI6, RKSOI) that show SOI (silicon on insulator) device response can be more complicated than originally suggested by others. The major difference between the 2 process versions is that the RKSOI process incorporates special techniques to minimize pre-irradiation parasitic leakage current from trench sidewalls. Transistors were irradiated at room temperature using 10 keV X-ray source. Worst-case bias configuration for total-dose testing fully-depleted SOI transistors was found to be process dependent. It appears that the worst-case bias for HYPOI6 process is the bias that causes the largest increase in sidewall leakage. The RKSOI process shows a different response during irradiation, the transition response appears to be dominated by charge trapping in the buried oxide. These results have implications for hardness assurance testing. (A.C.)

  14. Anti-tumor effect of total body irradiation of low doses on WHT/Ht mice

    International Nuclear Information System (INIS)

    Miyamoto, Miyako; Sakamoto, Kiyohiko

    1987-01-01

    The effect of low dose (0.05 - 1.0 Gy) of total body irradiation (TBI) on non-tumor bearing and tumor bearing mice were investigated. Mice received TBI of 0.1 Gy during 6 - 12 hours before tumor cell inoculation demonstrated to need larger number of tumor cells (approximately 2.5 times) for 50 per cent tumor incidence, compared to recipient mice not to receive TBI. On the other hand, in tumor bearing mice given 0.1 Gy of TBI only tumor cell killing effect was not detected, however enhancement of tumor cell killing effect and prolonged growth delay were observed when tumor bearing mice were treated with 0.1 Gy of TBI in combined with local irradiation on tumors, especially cell killing effect was remarkable in dose range over 6 Gy of local exposure. The mechanism of the effect of 0.1 Gy TBI is considered to be host mediated reactions from the other our experimental results. (author)

  15. TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

    Energy Technology Data Exchange (ETDEWEB)

    Yi, B; Xu, H; Mutaf, Y; Prado, K [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

  16. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    Science.gov (United States)

    Zheng, Qi-Wen; Yu, Xue-Feng; Cui, Jiang-Wei; Guo, Qi; Ren, Di-Yuan; Cong, Zhong-Chao; Zhou, Hang

    2014-10-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device.

  17. Results of radiotherapy with different doses in epicondylitis humeri. Ergebnisse der Strahlentherapie der Epicondylitis humeri bei unterschiedlicher Dosierung

    Energy Technology Data Exchange (ETDEWEB)

    Kammerer, R.; Bollmann, G.; Schwenger, P.; Michael, G.; Koeppen, D. (Klinik fuer Radiologie, Medizinische Akademie Magdeburg (Germany))

    1990-01-01

    In a prospective analysis the effectiveness of roentgen irradiation with minimal doses (daily single dosis 0.3Gy up to a total dose of 1.5Gy) was investigated in 207 patients with an epicondylitis humeri. Compared with a group of 92 patients, who were irradiated with higher doses beeing in general use (weekly 2 x single dosis 1.0 Gy to a total dose of 4.0 Gy), the therapeutic results show no sihnificant differences. After termination of the first irradiation series an improvement of complaints was seen in half of the patients (48.8% or 50.0%). A further increase of the quota in success to 74.9% or 70.6% was found 6 weeks after termination or irradiation. By reason of radiotherapeutic results, mainly attained in chronic states of epicondylitis humeri after primary conservative therapy without success for months and partly surgical pretreatment, the radiotherapy should be used more frequently than till now, especially in consideration of its slight side-effects and injuries of patients. (orig.).

  18. Total Skin Electron Beam Therapy in the Treatment of Mycosis Fungoides: A Review of Conventional and Low-Dose Regimens.

    Science.gov (United States)

    Chowdhary, Mudit; Chhabra, Arpit M; Kharod, Shivam; Marwaha, Gaurav

    2016-12-01

    Mycosis fungoides (MF) is the most prevalent subtype of cutaneous T-cell lymphoma, which is characterized by the proliferation of CD4 + T cells. While often an indolent disease, most patients eventually develop progression from isolated patches to tumors and finally nodal or visceral involvement. Treatment choice is largely based on disease burden, though prognostic factors such as disease stage, patient age, and extracutaneous involvement must be taken into consideration. Radiotherapy represents one of the most effective therapeutic modalities in the treatment of MF. Lymphocytes are exquisitely radiosensitive, and excellent responses are observed even with low doses of radiation. Total skin electron beam therapy (TSEBT) is a special technique that allows for the homogenous irradiation of the entire skin. There are well-documented radiation dose-response relationships for achieving a complete response. As such, TSEBT doses ≥ 30 Gy comprise the current standard of care. Although highly effective, most patients experience recurrent disease even after conventional-dose (≥ 30 Gy) TSEBT. In addition, toxicity is cumulatively dose dependent, and there is reluctance to administer multiple courses of conventional-dose TSEBT. Consequently, there has been renewed interest in determining the utility of TSEBT at lower total (≤ 30 Gy) doses. Advantages of low-total-dose (with standard dose per fraction) TSEBT include a shortened treatment course, the potential to minimize the risk of adverse events, and the opportunity to allow for retreatment in cases of disease recurrence. This comprehensive review compares the impact of different TSEBT dosing schemes on clinical outcomes of MF. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Image-guided total marrow and total lymphatic irradiation using helical tomotherapy

    International Nuclear Information System (INIS)

    Schultheiss, Timothy E.; Wong, Jeffrey; Liu, An; Olivera, Gustavo; Somlo, George

    2007-01-01

    Purpose: To develop a treatment technique to spare normal tissue and allow dose escalation in total body irradiation (TBI). We have developed intensity-modulated radiotherapy techniques for the total marrow irradiation (TMI), total lymphatic irradiation, or total bone marrow plus lymphatic irradiation using helical tomotherapy. Methods and Materials: For TBI, we typically use 12 Gy in 10 fractions delivered at an extended source-to-surface distance (SSD). Using helical tomotherapy, it is possible to deliver equally effective doses to the bone marrow and lymphatics while sparing normal organs to a significant degree. In the TMI patients, whole body skeletal bone, including the ribs and sternum, comprise the treatment target. In the total lymphatic irradiation, the target is expanded to include the spleen and major lymph node areas. Sanctuary sites for disease (brain and testes) are included when clinically indicated. Spared organs include the lungs, esophagus, parotid glands, eyes, oral cavity, liver, kidneys, stomach, small and large intestine, bladder, and ovaries. Results: With TBI, all normal organs received the TBI dose; with TMI, total lymphatic irradiation, and total bone marrow plus lymphatic irradiation, the visceral organs are spared. For the first 6 patients treated with TMI, the median dose to organs at risk averaged 51% lower than would be achieved with TBI. By putting greater weight on the avoidance of specific organs, greater sparing was possible. Conclusion: Sparing of normal tissues and dose escalation is possible using helical tomotherapy. Late effects such as radiation pneumonitis, veno-occlusive disease, cataracts, neurocognitive effects, and the development of second tumors should be diminished in severity and frequency according to the dose reduction realized for the organs at risk

  20. Recent Total Ionizing Dose and Displacement Damage Compendium of Candidate Electronics for NASA Space Systems

    Science.gov (United States)

    Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.; hide

    2011-01-01

    Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.

  1. Effect of high-dose preoperative methylprednisolone on pain and recovery after total knee arthroplasty: a randomized, placebo-controlled trial

    DEFF Research Database (Denmark)

    Lunn, Troels; Kristensen, Billy Bjarne; Andersen, Lasse

    2011-01-01

    Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied.......Total knee arthroplasty (TKA) is associated with severe pain and inflammation despite an extensive multimodal analgesic approach, but the effect of high-dose glucocorticoid administration has not been studied....

  2. Pattern imprinting in deep sub-micron static random access memories induced by total dose irradiation

    International Nuclear Information System (INIS)

    Zheng Qi-Wen; Yu Xue-Feng; Cui Jiang-Wei; Guo Qi; Ren Di-Yuan; Cong Zhong-Chao; Zhou Hang

    2014-01-01

    Pattern imprinting in deep sub-micron static random access memories (SRAMs) during total dose irradiation is investigated in detail. As the dose accumulates, the data pattern of memory cells loading during irradiation is gradually imprinted on their background data pattern. We build a relationship between the memory cell's static noise margin (SNM) and the background data, and study the influence of irradiation on the probability density function of ΔSNM, which is the difference between two data sides' SNMs, to discuss the reason for pattern imprinting. Finally, we demonstrate that, for micron and deep sub-micron devices, the mechanism of pattern imprinting is the bias-dependent threshold shift of the transistor, but for a deep sub-micron device the shift results from charge trapping in the shallow trench isolation (STI) oxide rather than from the gate oxide of the micron-device. (condensed matter: structural, mechanical, and thermal properties)

  3. Synergistic effects of total ionizing dose on single event upset sensitivity in static random access memory under proton irradiation

    International Nuclear Information System (INIS)

    Xiao Yao; Guo Hong-Xia; Zhang Feng-Qi; Zhao Wen; Wang Yan-Ping; Zhang Ke-Ying; Ding Li-Li; Luo Yin-Hong; Wang Yuan-Ming; Fan Xue

    2014-01-01

    Synergistic effects of the total ionizing dose (TID) on the single event upset (SEU) sensitivity in static random access memories (SRAMs) were studied by using protons. The total dose was cumulated with high flux protons during the TID exposure, and the SEU cross section was tested with low flux protons at several cumulated dose steps. Because of the radiation-induced off-state leakage current increase of the CMOS transistors, the noise margin became asymmetric and the memory imprint effect was observed. (interdisciplinary physics and related areas of science and technology)

  4. Total-dose hardness assurance for low earth orbit

    International Nuclear Information System (INIS)

    Maurer, R.H.; Suter, J.J.

    1987-01-01

    The Low Earth Orbit radiation environment has two significant characteristics that make laboratory simulation exposures difficult: (1) a low dose rate and (2) many cycles of low dose accumulation followed by dose-free annealing. Hardness assurance considerations for this environment are discussed and related to data from the testing of Advanced Low Power Schottky and High-speed CMOS devices

  5. Tennessee Valley region study: potential year 2000 radiological dose to population resulting from nuclear facility operations

    International Nuclear Information System (INIS)

    1978-06-01

    A companion report, DOE/ET-0064/1, presents a geographic, cultural, and demographic profile of the Tennessee Valley Region study area. This report describes the calculations of radionuclide release and transport and of the resultant dose to the regional population, assuming a projected installed capacity of 220,000 MW in the year 2000, of which 144,000 MW would be nuclear. All elements of the fuel cycle were assumed to be in operation. The radiological dose was calculated as a one-year dose based on ingestion of 35 different food types as well as for nine non-food pathways, and was reported as dose to the total body and for six specific organs for each of four age groups (infant, child, teen, and adult). Results indicate that the average individual would receive an incremental dose of 7 x 10 -4 millirems in the year 2000 from the operation of nuclear facilities within and adjacent to the region, five orders of magnitude smaller than the dose from naturally occurring radiation in the area. The major contributor to dose was found to be tritium, and the most significant pathways were immersion in air, inhalation of air, transpiration of tritium (absorption through the skin), and exposure radionuclide-containing soil. 60 references

  6. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  7. A rapid infusion protocol is safe for total dose iron polymaltose: time for change.

    Science.gov (United States)

    Garg, M; Morrison, G; Friedman, A; Lau, A; Lau, D; Gibson, P R

    2011-07-01

    Intravenous correction of iron deficiency by total dose iron polymaltose is inexpensive and safe, but current protocols entail prolonged administration over more than 4 h. This results in reduced patient acceptance, and hospital resource strain. We aimed to assess prospectively the safety of a rapid intravenous protocol and compare this with historical controls. Consecutive patients in whom intravenous iron replacement was indicated were invited to have up to 1.5 g iron polymaltose by a 58-min infusion protocol after an initial 15-min test dose without pre-medication. Infusion-related adverse events (AE) and delayed AE over the ensuing 5 days were also prospectively documented and graded as mild, moderate or severe. One hundred patients, 63 female, mean age 54 (range 18-85) years were studied. Thirty-four infusion-related AE to iron polymaltose occurred in a total of 24 patients--25 mild, 8 moderate and 1 severe; higher than previously reported for a slow protocol iron infusion. Thirty-one delayed AE occurred in 26 patients--26 mild, 3 moderate and 2 severe; similar to previously reported. All but five patients reported they would prefer iron replacement through the rapid protocol again. The presence of inflammatory bowel disease (IBD) predicted infusion-related reactions (54% vs 14% without IBD, P cost, resource utilization and time benefits for the patient and hospital system. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  8. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    International Nuclear Information System (INIS)

    Lucero, J. F.; Rojas, J. I.

    2016-01-01

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  9. Clinical implementation of total skin electron irradiation treatment with a 6 MeV electron beam in high-dose total skin electron mode

    Energy Technology Data Exchange (ETDEWEB)

    Lucero, J. F., E-mail: fernando.lucero@hoperadiotherapy.com.gt [Universidad Nacional de Costa Rica, Heredia (Costa Rica); Hope International, Guatemala (Guatemala); Rojas, J. I., E-mail: isaac.rojas@siglo21.cr [Centro Médico Radioterapia Siglo XXI, San José (Costa Rica)

    2016-07-07

    Total skin electron irradiation (TSEI) is a special treatment technique offered by modern radiation oncology facilities, given for the treatment of mycosis fungoides, a rare skin disease, which is type of cutaneous T-cell lymphoma [1]. During treatment the patient’s entire skin is irradiated with a uniform dose. The aim of this work is to present implementation of total skin electron irradiation treatment using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films.

  10. Single dose total lymphoid irradiation combined with cyclophosphamide as immunosuppression for human marrow transplantation in aplastic anemia

    International Nuclear Information System (INIS)

    Kim, T.H.; Kersey, J.H.; Khan, F.M.; Sewchand, W.; Ramsey, N.; Krivit, W.; Coccia, P.; Nesbit, M.E.; Levitt, S.H.

    1979-01-01

    Six patients with aplastic anemia underwent bone marrow transplantation following conditioning with high dose cyclophosphamide and single dose total lymphoid irradiation with 750 rad, 26 rad/min at the midplane of the patient. They all received bone marrow from human leukocyte antigens/mixed lymphocyte culture (HLA/MLC) matched siblings. Five of 6 patients were alive without complications at 12, 11, 7, 4 and 4 months respectively. The remaining patient died from sepis which he had prior to transplantation. There were no graft rejection, graft-vs-Host Disease (GVHD) or interstitial pneumonitis among these patients. The procedure was well tolerated with minimal side effects. The results will be compared with those of groups whose bone marrow was previously transplanted with different immunosuppressive methods

  11. Time- and radiation-dose dependent changes in the plasma proteome after total body irradiation of non-human primates: Implications for biomarker selection.

    Directory of Open Access Journals (Sweden)

    Stephanie D Byrum

    Full Text Available Acute radiation syndrome (ARS is a complex multi-organ disease resulting from total body exposure to high doses of radiation. Individuals can be exposed to total body irradiation (TBI in a number of ways, including terrorist radiological weapons or nuclear accidents. In order to determine whether an individual has been exposed to high doses of radiation and needs countermeasure treatment, robust biomarkers are needed to estimate radiation exposure from biospecimens such as blood or urine. In order to identity such candidate biomarkers of radiation exposure, high-resolution proteomics was used to analyze plasma from non-human primates following whole body irradiation (Co-60 at 6.7 Gy and 7.4 Gy with a twelve day observation period. A total of 663 proteins were evaluated from the plasma proteome analysis. A panel of plasma proteins with characteristic time- and dose-dependent changes was identified. In addition to the plasma proteomics study reported here, we recently identified candidate biomarkers using urine from these same non-human primates. From the proteomic analysis of both plasma and urine, we identified ten overlapping proteins that significantly differentiate both time and dose variables. These shared plasma and urine proteins represent optimal candidate biomarkers of radiation exposure.

  12. TLD-300 detectors for separate measurement of total and gamma absorbed dose distributions of single, multiple, and moving-field neutron treatments

    International Nuclear Information System (INIS)

    Rassow, J.

    1984-01-01

    Fast neutron therapy requirements, because of the poor depth dose characteristic of present therapeutical sources, are at least as complex in treatment plans as photon therapy. The physical part of the treatment planning is very important; however, it is much more complicated than for photons or electrons owing to the need for: Separation of total and gamma absorbed dose distributions (Dsub(T) and Dsub(G)); and more stringent tissue-equivalence conditions of phantoms than in photon therapy. Therefore, methods of clinical dosimetry for the separate determination of total and gamma absorbed dose distributions in irregularly shaped (inhomogeneous) phantoms are needed. A method using TLD-300 (CaF 2 :Tm) detectors is described, which is able to give an approximate solution of the above-mentioned dosimetric requirements. The two independent doses, Dsub(T) and Dsub(G), can be calculated by an on-line computer analysis of the digitalized glow curve of TLD-300 detectors, irradiated with d(14)+Be neutrons of the cyclotron isocentric neutron therapy facility CIRCE in Essen. Results are presented for depth and lateral absorbed dose distributions (Dsub(T) and Dsub(G)) for fixed neutron beams of different field sizes compared with measurements by standard procedures (TE-TE ionization chamber, GM counter) in an A-150 phantom. The TLD-300 results for multiple and moving-field treatments (with and without wedge filters) in a patient simulating irregularly shaped (inhomogeneous) phantoms, are shown together with computer calculations of these dose distributions. The probable causes for some systematic deviations are discussed, which lead to open problems for further investigations owing to features of the detector material and the evaluation method, but mainly to differences in the composition of phantom materials used for the calculations (standard dose distributions) and TLD-300 measurements. (author)

  13. Low-dose dual-energy cone-beam CT using a total-variation minimization algorithm

    International Nuclear Information System (INIS)

    Min, Jong Hwan

    2011-02-01

    Dual-energy cone-beam CT is an important imaging modality in diagnostic applications, and may also find its use in other application such as therapeutic image guidance. Despite of its clinical values, relatively high radiation dose of dual-energy scan may pose a challenge to its wide use. In this work, we investigated a low-dose, pre-reconstruction type of dual-energy cone-beam CT (CBCT) using a total-variation minimization algorithm for image reconstruction. An empirical dual-energy calibration method was used to prepare material-specific projection data. Raw data at high and low tube voltages are converted into a set of basis functions which can be linearly combined to produce material-specific data using the coefficients obtained through the calibration process. From much fewer views than are conventionally used, material specific images are reconstructed by use of the total-variation minimization algorithm. An experimental study was performed to demonstrate the feasibility of the proposed method using a micro-CT system. We have reconstructed images of the phantoms from only 90 projections acquired at tube voltages of 40 kVp and 90 kVp each. Aluminum-only and acryl-only images were successfully decomposed. We evaluated the quality of the reconstructed images by use of contrast-to-noise ratio and detectability. A low-dose dual-energy CBCT can be realized via the proposed method by greatly reducing the number of projections

  14. Enrichment increases hippocampal neurogenesis independent of blood monocyte-derived microglia presence following high-dose total body irradiation.

    Science.gov (United States)

    Ruitenberg, Marc J; Wells, Julia; Bartlett, Perry F; Harvey, Alan R; Vukovic, Jana

    2017-06-01

    Birth of new neurons in the hippocampus persists in the brain of adult mammals and critically underpins optimal learning and memory. The process of adult neurogenesis is significantly reduced following brain irradiation and this correlates with impaired cognitive function. In this study, we aimed to compare the long-term effects of two environmental paradigms (i.e. enriched environment and exercise) on adult neurogenesis following high-dose (10Gy) total body irradiation. When housed in standard (sedentary) conditions, irradiated mice revealed a long-lasting (up to 4 months) deficit in neurogenesis in the granule cell layer of the dentate gyrus, the region that harbors the neurogenic niche. This depressive effect of total body irradiation on adult neurogenesis was partially alleviated by exposure to enriched environment but not voluntary exercise, where mice were single-housed with unlimited access to a running wheel. Exposure to voluntary exercise, but not enriched environment, did lead to significant increases in microglia density in the granule cell layer of the hippocampus; our study shows that these changes result from local microglia proliferation rather than recruitment and infiltration of circulating Cx 3 cr1 +/gfp blood monocytes that subsequently differentiate into microglia-like cells. In summary, latent neural precursor cells remain present in the neurogenic niche of the adult hippocampus up to 8 weeks following high-dose total body irradiation. Environmental enrichment can partially restore the adult neurogenic process in this part of the brain following high-dose irradiation, and this was found to be independent of blood monocyte-derived microglia presence. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  15. Effect of radiation dose rate and cyclophosphamide on pulmonary toxicity after total body irradiation in a mouse model

    International Nuclear Information System (INIS)

    Safwat, Akmal; Nielsen, Ole S.; El-Badawy, Samy; Overgaard, Jens

    1996-01-01

    Purpose: Interstitial pneumonitis (IP) is still a major complication after total body irradiation (TBI) and bone marrow transplantation (BMT). It is difficult to determine the exact role of radiation in this multifactorial complication, especially because most of the experimental work on lung damage was done using localized lung irradiation and not TBI. We have thus tested the effect of radiation dose rate and combining cyclophosphamide (CTX) with single fraction TBI on lung damage in a mouse model for BMT. Methods and Materials: TBI was given as a single fraction at a high dose rate (HDR, 0.71 Gy/min) or a low dose rate (LDR, 0.08 Gy/min). CTX (250 mg/kg) was given 24 h before TBI. Bone marrow transplantation (BMT) was performed 4-6 h after the last treatment. Lung damage was assessed using ventilation rate (VR) and lethality between 28 and 180 days (LD (50(28))-180 ). Results: The LD 50 for lung damage, ± standard error (SE), increased from 12.0 (± 0.2) Gy using single fraction HDR to 15.8 (± 0.6) Gy using LDR. Adding CTX shifted the dose-response curves towards lower doses. The LD 50 values for the combined treatment were 5.3 (± 0.2) and 3.5 (± 0.2) Gy for HDR and LDR, respectively. This indicates that the combined effect of CTX and LDR was more toxic than that of combined CTX and HDR. Lung damage evaluated by VR demonstrated two waves of VR increase. The first wave of VR increase occurred after 6 weeks using TBI only and after 3 weeks in the combined CTX-TBI treatment, irrespective of total dose or dose rate. The second wave of VR elevation resembled the IP that follows localized thoracic irradiation in its time of occurrence. Conclusions: Lung damage following TBI could be spared using LDR. However, CTX markedly enhances TBI-induced lung damage. The combination of CTX and LDR is more toxic to the lungs than combining CTX and HDR

  16. Low-dose total skin electron beam therapy for cutaneous lymphoma. Minimal risk of acute toxicities

    Energy Technology Data Exchange (ETDEWEB)

    Kroeger, Kai; Elsayad, Khaled; Moustakis, Christos; Haverkamp, Uwe; Eich, Hans Theodor [University Hospital of Muenster, Department of Radiation Oncology, Muenster (Germany)

    2017-12-15

    Low-dose total skin electron beam therapy (TSEBT) is attracting increased interest for the effective palliative treatment of primary cutaneous T-cell lymphoma (pCTCL). In this study, we compared toxicity profiles following various radiation doses. We reviewed the records of 60 patients who underwent TSEBT for pCTCL between 2000 and 2016 at the University Hospital of Munster. The treatment characteristics of the radiotherapy (RT) regimens and adverse events (AEs) were then analyzed and compared. In total, 67 courses of TSEBT were administered to 60 patients. Of these patients, 34 (51%) received a standard dose with a median surface dose of 30 Gy and 33 patients (49%) received a low dose with the median surface dose of 12 Gy (7 salvage low-dose TSEBT courses were administered to 5 patients). After a median follow-up of 15 months, the overall AE rate was 100%, including 38 patients (57%) with grade 2 and 7 (10%) with grade 3 AEs. Patients treated with low-dose TSEBT had significantly fewer grade 2 AEs than those with conventional dose regimens (33 vs. 79%, P < 0.001). A lower grade 3 AE rate was also observed in patients who had received the low-dose regimen compared to those with the conventional dose regimens (6 vs. 15%, P = 0.78). Multiple/salvage low-dose TSEBT courses were not associated with an increased risk of acute AEs. Low-dose TSEBT regimens are associated with significantly fewer grade 2 acute toxicities compared with conventional doses of TSEBT. Repeated/Salvage low-dose TSEBT, however, appears to be tolerable and can even be applied safely in patients with cutaneous relapses. (orig.) [German] Eine niedrigdosierte Ganzhautelektronenbestrahlung (TSEBT) wird vermehrt zur effektiven palliativen Behandlung von Patienten mit primaer kutanen T-Zell-Lymphomen (pCTCL) eingesetzt. In dieser Studie vergleichen wir die Toxizitaetsprofile verschiedener Dosiskonzepte. Untersucht wurden 60 zwischen 2000 und 2016 am Universitaetsklinikum Muenster mittels TSEBT

  17. Unscheduled DNA synthesis in spleen cells of mice exposed to low doses of total body irradiation

    International Nuclear Information System (INIS)

    Tuschl, H.; Kovac, R.; Hruby, E.

    1983-07-01

    Unscheduled DNA synthesis was induced by UV irradiation of spleen cells obtained from C 57 Bl mice after repeated total body irradiation of 0.05 Gy 60 Co (0.00125 Gy/mice) and determined autoradiographically. An enhancement in the ability for repair of UV induced DNA lesions was observed in cells of gamma irradiated animals. While the amount of 3 H-thymidine incorporated per cell was increased, the percentage of labeled cells remained unchanged. The present results are compared with previous data on low dose radiation exposure in men. (Author) [de

  18. Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Radiology, Genoa (Italy); Origgi, Daniela; Palorini, Federica [Istituto Europeo di Oncologia, Department of Medical Physics, Milan (Italy); Matranga, Domenica [University of Palermo, Department of Sciences for Health Promotion and Mother and Child Care ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [University of Palermo, Department of Medical and Forensic Biopathology and Biotechnologies, Section of Radiology, Palermo (Italy)

    2015-05-01

    Multidetector CT (MDCT) scanners have contributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition parameters of CT examinations in three age groups (1-5, 6-10, 11-15 years) for studies of head, chest and abdomen. The dosimetric results were reported in terms of third-quartile volumetric CT dose index (CTDI{sub vol}) (mGy), size-specific dose estimate (SSDE) (mGy), dose length product (DLP) (mGy cm), and total DLP for multiphase studies. These results were compared with paediatric European and adult Italian published data. A multivariate analysis assessed the association of CTDI{sub vol} with patient characteristics and scanning modalities. We collected data from 993 MDCT examinations performed at 25 centres. For age groups 1-5 years, 6-10 years and 11-15 years, the CTDI{sub vol}, DLP and total DLP values were statistically significantly below the values observed in our analogous national survey in adults, although the difference decreased with increasing age. CTDI{sub vol} variability among centres was statistically significant (variance = 0.07; 95% confidence interval = 0.03-0.16; P < 0.001). This study reviewed practice in Italian centres performing paediatric imaging with MDCT scanners. The variability of doses among centres suggests that the use of standardised CT protocols should be encouraged. (orig.)

  19. Higher hydrocortisone dose increases bilirubin in hypopituitary patients- results from an RCT.

    Science.gov (United States)

    Werumeus Buning, Jorien; Kootstra-Ros, Jenny E; Brummelman, Pauline; van den Berg, Gerrit; van der Klauw, Melanie; Wolffenbuttel, Bruce H R; van Beek, André P; Dullaart, Robin P F

    2016-05-01

    Bilirubin has anti-oxidative and anti-inflammatory properties, which may explain its proposed protective effects on the development of cardiometabolic disorders. Glucocorticoids affect heme oxygenase regulation in vitro, which plays a key role in bilirubin production. Effects of variations in glucocorticoid exposure on circulating bilirubin levels in humans are unknown. Here we tested whether a higher hydrocortisone replacement dose affects circulating bilirubin in hypopituitary patients. A randomized double-blind cross-over study (ClinicalTrials.gov, number NCT01546992) was performed in 47 patients with secondary adrenal failure [10-week exposure to a higher hydrocortisone dose (0·4-0·6 mg/kg body weight) vs. 10 weeks of a lower hydrocortisone dose (0·2-0·3 mg/kg body weight)]. Plasma total bilirubin was increased by 10% from 7 to 8 μM in response to the higher hydrocortisone dose (P = 0·033). This effect was inversely related to age (P = 0·042), but was unaffected by sex, obesity and (replacement for) other hormonal insufficiencies. The higher hydrocortisone dose also resulted in lower alkaline phosphatase (P = 0·006) and aspartate aminotransferase activities (P = 0·001). Bilirubin is modestly increased in response to higher glucocorticoid exposure in humans, in conjunction with lower alkaline phosphatase and aspartate aminotransferase activities, which are supposed to represent biomarkers of a pro-inflammatory state and enhanced liver fat accumulation. © 2016 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.

  20. Use of BEIR V and UNSCEAR 1988 in radiation risk assessment: Lifetime total cancer mortality risk estimates at low doses and low dose rates for low-LET radiation

    International Nuclear Information System (INIS)

    1992-12-01

    In November 1986, the Department of Defense (DoD) asked the Committee on Interagency Radiation Research and Policy Coordination (CIRRPC) to develop a coordinated Federal position on risk assessment for low levels of ionizing radiation. Since Federal risk assessment activities are based primarily on the scientific data and analyses in authoritative review documents prepared by groups like the National Academy of Sciences' Committee on the Biological Effects of Ionizing Radiation (BEIR), the National Council on Radiation Protection and Measurements (NCRP) and the United Nations' Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), DoD proposed that the CIRRPC Science Panel undertake the task of providing coordinated interagency positions on the use of information in the reports of such groups. The practice has been for individual Federal agencies to interpret and decide independently how to use the information provided in such reports. As a result of its deliberations, the Subpanel recommends two nominal risk estimates for lifetime total cancer mortality following whole-body exposure to low levels of low-LET ionizing radiation, one for the general population and one for the working-age population (see Section II). The recommended risk estimates reflect the general agreement of information in BEIR V and UNSCEAR 1988 for total cancer mortality. The Subpanel's risk estimates and associated statements are intended to meet the needs of the Federal agencies for: (a) values that are current; (b) values that are relevant to the low-dose and low dose-rate ionizing radiation exposures principally encountered in carrying out Federal responsibilities; (c) a statement of the change in the estimates of lifetime total cancer mortality relative to estimates in previous authoritative review documents; and (d) a practical statement on the scientific uncertainty associated with applying the lifetime total cancer mortality values at very low doses

  1. The review of radiation effects of γ total dose in CMOS circuits

    International Nuclear Information System (INIS)

    Chen Panxun; Gao Wenming; Xie Zeyuan; Mi Bang

    1992-01-01

    Radiation performances of commercial and rad-hard CMOS circuits are reviewed. Threshold voltage, static power current, V in -V out characteristic and propagation delay time related with total dose are presented for CMOS circuits from several manufacturing processes. The performance of radiation-annealing of experimental circuits had been observed for two years. The comparison has been made between the CMOS circuits made in China and the commercial RCA products. 60 Co γ source can serve as γ simulator of the nuclear explosion

  2. A Cs-137 afterloading device. Preliminary results of cell kinetic effects of low dose-rate irradiation in an experimental tumour

    International Nuclear Information System (INIS)

    Rutgers, D.H.

    1988-01-01

    A Cs-137 afterloading technique is described which can be used in experimental tumours. Preliminary results, obtained with the human cervical carcinoma ME-180 xenografted to nude athymic mice, demonstrated that 20 Gy of low dose-rate irradiation induced an important redistribution of cells over cell cycle. The proportion of cells in G2-phase increased from 14.4% to 44.2% at 140 hours after irradiation. This method allows an accurate calculation of the dose-rate distribution in the tumour. Investigations of the cell kinetic effects of low dose-rate irradiation, at different dose-rates and different total doses, are therefore facilitated by the technique. (orig.) [de

  3. CY 1995 radiation dose reconciliation report and resulting CY 1996 dose estimate for the 324 nuclear facility

    International Nuclear Information System (INIS)

    Landsman, S.D.; Thornhill, R.E.; Peterson, C.A.

    1996-04-01

    In this report, the dose estimate for CY 1995 is reconciled by month wih actual doses received. Results of the reconciliation were used to revise estimates of worker dose for CY 1996. Resulting dose estimate for the facility is also included. Support for two major programs (B-Cell Cleanout and Surveillance and Maintenance) accounts for most of the exposure received by workers in the faility. Most of the expousre received by workers comes from work in the Radiochemical Engineering Complex airlock. In spite of schedule and work scope changes during CY 1995, dose estimates were close to actual exposures received. A number of ALARA measures were taken throughout the year; exposure reduction due to those was 20.6 Man-Rem, a 28% reduction from the CY 1995 estimate. Baseline estimates for various tasks in the facility were used to compile the CY 1996 dose estimate of 45.4 Man-Rem; facility goal for CY 1996 is to reduce worker dose by 20%, to 36.3 Man-Rem

  4. Effect of treatment with single total-dose intravenous iron versus daily oral iron(III-hydroxide polymaltose on moderate puerperal iron-deficiency anemia

    Directory of Open Access Journals (Sweden)

    Iyoke CA

    2017-05-01

    Full Text Available Chukwuemeka Anthony Iyoke,1 Fausta Chioma Emegoakor,1 Euzebus Chinonye Ezugwu,1 Lucky Osaheni Lawani,2 Leonard Ogbonna Ajah,1 Jude Anazoeze Madu,3 Hyginus Uzo Ezegwui,1 Frank Okechukwu Ezugwu4 1Department of Obstetrics and Gynaecology, University of Nigeria, Enugu Campus, 2Department of Obstetrics and Gynaecology, Federal Teaching Hospital, Abakaliki, 3Department of Haematology, University of Nigeria, Nsukka, 4Department of Obstetrics and Gynaecology, College of Medicine, Enugu State University, Enugu, Nigeria Background: Iron-deficiency anemia is the most common nutritional cause of anemia in pregnancy and is often responsible for puerperal anemia. Puerperal anemia can impair postpartum maternal and neonatal well-being. Objective: To determine the effect of treatment of moderate puerperal iron-deficiency anemia using a single intravenous total-dose iron dextran versus daily single dose oral iron(III-hydroxide polymaltose. Methodology: A randomized controlled study in which postpartum women with moderate iron-deficiency anemia were randomized into treatment with either a single total-dose intravenous iron dextran or with daily single doses of oral iron(III-hydroxide polymaltose tablets for 6 weeks. Effects on hemoglobin concentration using either method were compared at 6 weeks postpartum. Analysis was per protocol using SPSS version 17 for windows. P-values ≤0.05 were considered significant. Results: Two hundred eighty-four women were recruited for the study: 142 women received single total dose intravenous infusion of iron dextran while 142 received daily oral iron(III-hydroxide polymaltose tablets. Approximately 84.0% (237/282 completed the study and were analyzed including 81% (115/142 of those randomized to injectable iron therapy compared to 85.9% (122/142 of those randomized to oral treatment. The proportions of women who had attained hemoglobin concentration of at least 10 g/dL by the 6 weeks postpartum visit did not differ

  5. Influence of radioprotectors on total body weight evolution and on oxygen consumption in lethal dose irradiated animals. (Preliminary study)

    International Nuclear Information System (INIS)

    Fatome, M.; Martine, G.; Bargy, E.; Andrieu, L.

    Comparison of total body weight evolution and oxygen consumption in lethal dose irradiated animals, protected by various well known radioprotective substances, isolated or in mixture, with evolution and consumption of non protected animals irradiated at the same dose and with these of check animals [fr

  6. A trial of radiation dose prescription based on dose-cell survival formula

    International Nuclear Information System (INIS)

    Allen, E.P.

    1984-01-01

    Radiation treatment has been prescribed for 379 basal cell carcinomata on the basis of a selected equivalent single dose derived from the standard multi-target dose-cell survival formula using values of m = 2 and Do = 130 rads for orthovoltage x-rays. The results suggest that the approach provides a flexible and acceptable alternative to prescription by total dose or by Nominal Standard Dose. It is submitted that Total Dose is an inadequate expression of radiobiological effects: that the NSD and related systems are valuable measures of the ability of normal tissues to recover from radiation damage: and that a parallel measure of the degree of tumour depopulation has become necessary to allow further progress in alternative fractionation schedules

  7. Northern Marshall Islands radiological survey: terrestrial food chain and total doses

    International Nuclear Information System (INIS)

    Robison, W.L.; Mount, M.E.; Phillips, W.A.; Conrado, C.A.; Stuart, M.L.; Stoker, C.E.

    1982-01-01

    A radiological survey was conducted from September through November of 1978 to assess the concentrations of persistent manmade radionuclides in the terrestrial and marine environments of 11 atolls and 2 islands in the Northern Marshall Islands. The survey consisted mainly of an aerial radiological reconnaissance to map the external gamma-ray exposure rates over the islands of each atoll. The logistical support for the entire survey was designed to accommodate this operation. As a secondary phase of the survey, shore parties collected appropriate terrestrial and marine samples to assess the radiological dose from pertinent food chains to those individuals residing on the atolls, who may in the future reside on some of the presently uninhabited atolls, or who collect food from these atolls. Over 5000 terrestrial and marine samples were collected for radionuclide analysis from 76 different islands. Soils, vegetation, indigenous animals, and cistern water and groundwater were collected from the islands. Reef and pelagic fish, clams, lagoon water, and sediments were obtained from the lagoons. The concentration data for 90 Sr, 137 Cs, 238 Pu, 239 240 Pu, and 241 Am in terrestrial food crops, fowl, and animals collected at the atolls or islands are summarized. An assessment of the total dose from the major exposure pathways including external gamma, terrestrial food chain including food products and drinking water, marine food chain, and inhalation is provided. Radiological doses at each atoll or island are calculated from the average radionuclide concentrations in the terrestrial foods, marine foods, etc. assuming the average daily intake for each food item

  8. Pill content, dose and resulting plasma concentrations of 3,4-methylendioxymethamphetamine (MDMA) in recreational 'ecstasy' users.

    Science.gov (United States)

    Morefield, Kate M; Keane, Michael; Felgate, Peter; White, Jason M; Irvine, Rodney J

    2011-07-01

    To improve our understanding of the pharmacology of 'ecstasy' in recreational environments; in particular, to describe the composition of ecstasy pills, patterns of ecstasy use and the relationship between dose of 3,4-methylendioxymethamphetamine (MDMA) and resulting plasma concentrations. A naturalistic observational study of 56 experienced 'ecstasy' users in recreational settings in Australia. Drug use patterns (number of pills consumed, other drugs consumed). drug content of pills and resultant plasma concentrations of MDMA and related drugs were assessed by gas chromatography/mass spectrometry (GC/MS). Ecstasy pills generally contained MDMA, but this was often combined with other drugs such as 3,4-ethylendioxyethylamphetamine (MDEA) and methamphetamine. The dose of MDMA per pill ranged from 0 to 245 mg and users consumed from one-half to five pills, with the total dose consumed ranging up to 280 mg. Plasma concentrations of MDMA increased with number of pills consumed and cumulative MDMA dose. Use of larger numbers of pills was associated with extended exposure to the drug. MDMA is the major active drug in ecstasy pills, but there is a high degree of variation in doses. Use of multiple pills over the course of one session is common and results in a sustained increase in MDMA plasma concentrations over a number of hours. This is likely to lead to a much greater exposure of the brain to MDMA than would be predicted from controlled single-dose pharmacokinetic studies. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  9. Total body irradiation: current indications; L`irradiation corporelle totale: les indications actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Giraud, P.; Danhier, S.; Dubray, B.; Cosset, J.M. [Institut Curie, 75 - Paris (France)

    1998-05-01

    The choice of dose and fractionation for total body irradiation is made difficult by the large number of considerations to be taken into account. The outcome of bone marrow transplantation after total body irradiation can be understood in terms of tumor cell killing, engraftment, and normal tissue damage, each of these endpoints being influenced by irradiation-, disease-, transplant-, and patient- related factors. Interpretation of clinical data is further hampered by the overwhelming influence of logistic constraints, the small numbers of randomized studies, and the concomitant variations in total dose and fraction size or dose rate. So far, three cautious conclusions can be drawn in order to tentatively adapt the total body irradiation schedule to clinically-relevant situations. Firstly, the organs at risk for normal tissue damage (lung, liver, lens, kidney) are protected by delivering small doses per fraction at low dose rate. This suggests that, when toxicity is at stake (e.g. in children), fractionated irradiation should be preferred, provided that inter-fraction intervals are long enough. Secondly, fractionated irradiation should be avoided in case of T-cell depleted transplant, given the high risk of graft rejection in this setting. An alternative would be to increase total (or fractional) dose of fractionated total body irradiation, but this approach is likely to induce more normal tissue toxicity. Thirdly, clinical data have shown higher relapse rates in chronic myeloid leukemia after fractionated or low dose rate total body irradiation, suggesting that fractionated irradiation should not be recommended, unless total (or fractional) dose is increased. Total body irradiation-containing regimens, primarily cyclophosphamide / total body irradiation, are either equivalent to or better than the chemotherapy-only regimens, primarily busulfan / cyclophosphamide. Busulfan / cyclophosphamide certainly represents a reasonable alternative, especially in patients who

  10. Urinary excretion of total isothiocyanates from cruciferous vegetables shows high dose-response relationship and may be a useful biomarker for isothiocyanate exposure

    DEFF Research Database (Denmark)

    Kristensen, Mette; Krogholm, Kirstine Suszkiewicz; Frederiksen, Hanne

    2007-01-01

    in urine was quanti- fied as the cyclocondensation product of 1,2-bezenedithiol by high performance liquid chromatography. Results The total urinary excretion of ITCs correlated significantly with the two doses of ITC from diets with high or low cruciferous content (r(s) = 0.90, P

  11. IAEA/ WHO TLD postal dose intercomparison results in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Bhuiyan, N.U.; Rahman, S.

    2001-01-01

    Full text: For the accurate delivery of prescribed dose to the patients, high precision and accuracy in radiation dosimetry is required. The hospital/medical physicist is responsible for the accurate delivery of whole planned radiation doses to the patients prescribed by the radio therapist. The proper delivery of radiation doses depends upon the accurate output measurements of doses from the therapy machines. In Bangladesh, only six 60 Co units and five deep therapy machines are in use. Some more are expected to be installed soon. Still in 2001, none of the Government radiotherapy centers in Bangladesh was properly equipped with medical physicists as well as radiotherapy dosimetry equipment. Bangladesh Atomic Energy Commission (BAEC) is responsible for radiation safety in Bangladesh and BAEC has assigned Secondary Standard Dosimetry Laboratory (SSDL) of Bangladesh for providing dosimetry calibration to all radiotherapy centers in Bangladesh. The output measurements of therapy machines are performed once in a year by SSDL and the results are compared by participating in the annual TLD postal dose intercomparison program organized by IAEA/WHO SSDL Network. The absorbed dose to water is determined using IAEA dosimetry protocol (TRS 277 and 381) and water phantom of size 30 x 30 x 30 cm 3 , The measurements of SSDL are traceable to NPL of UK. The accuracy achieved in SSDL, Bangladesh has been found better than ± 3.5%, which is within the prescribed limit of dosimetry standard of IAEA. The methodology of output dose measurements in different radiotherapy centers in Bangladesh is described along with the IAEA/WHO intercomparison results

  12. Tennessee Valley region study: potential year 2000 radiological dose to population resulting from nuclear facility operations. [Includes glossary

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-06-01

    A companion report, DOE/ET-0064/1, presents a geographic, cultural, and demographic profile of the Tennessee Valley Region study area. This report describes the calculations of radionuclide release and transport and of the resultant dose to the regional population, assuming a projected installed capacity of 220,000 MW in the year 2000, of which 144,000 MW would be nuclear. All elements of the fuel cycle were assumed to be in operation. The radiological dose was calculated as a one-year dose based on ingestion of 35 different food types as well as for nine non-food pathways, and was reported as dose to the total body and for six specific organs for each of four age groups (infant, child, teen, and adult). Results indicate that the average individual would receive an incremental dose of 7 x 10/sup -4/ millirems in the year 2000 from the operation of nuclear facilities within and adjacent to the region, five orders of magnitude smaller than the dose from naturally occurring radiation in the area. The major contributor to dose was found to be tritium, and the most significant pathways were immersion in air, inhalation of air, transpiration of tritium (absorption through the skin), and exposure radionuclide-containing soil. 60 references.

  13. Analysis of functional failure mode of commercial deep sub-micron SRAM induced by total dose irradiation

    International Nuclear Information System (INIS)

    Zheng Qi-Wen; Cui Jiang-Wei; Zhou Hang; Yu De-Zhao; Yu Xue-Feng; Lu Wu; Guo Qi; Ren Di-Yuan

    2015-01-01

    Functional failure mode of commercial deep sub-micron static random access memory (SRAM) induced by total dose irradiation is experimentally analyzed and verified by circuit simulation. We extensively characterize the functional failure mode of the device by testing its electrical parameters and function with test patterns covering different functional failure modes. Experimental results reveal that the functional failure mode of the device is a temporary function interruption caused by peripheral circuits being sensitive to the standby current rising. By including radiation-induced threshold shift and off-state leakage current in memory cell transistors, we simulate the influence of radiation on the functionality of the memory cell. Simulation results reveal that the memory cell is tolerant to irradiation due to its high stability, which agrees with our experimental result. (paper)

  14. THE RESULTS OF INDIVIDUAL DOSE CONTROL OF HEALTH INSTITUTIONS STAFF

    Directory of Open Access Journals (Sweden)

    E. N. Shleenkova

    2014-01-01

    Full Text Available The  work  provides  comparative  assessment  of  the  levels  of  occupational  exposure  of  Saint-Petersburg health institutions staff. The analysis was carried out of the 891 individual doses measurement results which have  being  obtained  during  5  years  investigations  (2009-2013.  The  comparing  of  the  average  annual effective doses was carried out for 4 groups of medical specialists: x-ray laboratory assistant, radiotherapist, radiographer of dental clinics and X-ray surgery staff (surgeons, anesthesiologists and surgical nurses who are working close to irradiation source. It is shown that the annual effective dose average value is about 0.5 mSv for the first three groups of medical specialists. The same value for X-ray surgery staff is 1.6 mSv. Individual  annual  exposure  doses  have  not  exceeded  the  main  dose  limits  required  by  Radiation  Safety Standard 99/2009. The issues are considered of the estimation exactness of the effective dose basing on the results of individual dose equivalent measurement. 

  15. Total-ionizing-dose effects on isolation oxides in modern CMOS technologies

    International Nuclear Information System (INIS)

    Barnaby, Hugh J.; Mclain, Michael; Esqueda, Ivan Sanchez

    2007-01-01

    This paper presents experimental data on the total dose response of deep sub-micron bulk CMOS devices and integrated circuits. Ionizing radiation experiments on shallow trench isolation (STI) field oxide MOS capacitors (FOXCAP) indicate a characteristic build-up of radiation-induced defects in the dielectric. In this paper, capacitors fabricated with STI, thermal, SIMOX and bipolar base oxides of similar thickness are compared and show the STI oxide to be most susceptible to radiation effects. Experimental data on irradiated shift registers and n-channel MOSFETs are also presented. These data indicate that radiation damage to the STI can increase the off-state current of n-channel devices and the standby current of CMOS integrated circuits

  16. Simulation and measurement of total ionizing dose radiation induced image lag increase in pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China); State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Chen, Wei, E-mail: chenwei@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Wang, Zujun, E-mail: wangzujun@nint.ac.cn [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China); Xue, Yuanyuan; Yao, Zhibin; He, Baoping; Ma, Wuying; Jin, Junshan; Sheng, Jiangkun; Dong, Guantao [State Key Laboratory of Intense Pulsed Irradiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an (China)

    2017-06-01

    This paper presents an investigation of total ionizing dose (TID) induced image lag sources in pinned photodiodes (PPD) CMOS image sensors based on radiation experiments and TCAD simulation. The radiation experiments have been carried out at the Cobalt −60 gamma-ray source. The experimental results show the image lag degradation is more and more serious with increasing TID. Combining with the TCAD simulation results, we can confirm that the junction of PPD and transfer gate (TG) is an important region forming image lag during irradiation. These simulations demonstrate that TID can generate a potential pocket leading to incomplete transfer.

  17. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids: Feasibility and Early Results

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping, E-mail: ping.jiang@uksh.de [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Baumann, René [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Dunst, Juergen [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, University of Copenhagen, Copenhagen (Denmark); Geenen, Matthias [Department of Reconstructive Surgery, Lubinus Clinic Kiel, Kiel (Germany); Siebert, Frank-André [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Niehoff, Peter [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, Community Clinic Köln, Köln (Germany); Department of Radiation Oncology, University Witten/Herdecke, Witten (Germany); Bertolini, Julia; Druecke, Daniel [Department of Reconstructive Surgery, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany)

    2016-03-01

    Purpose: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. Methods and Materials: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immediate perioperative high-dose-rate brachytherapy; 3 patients had been previously treated with adjuvant external beam radiation therapy and presented with recurrences in the pretreated areas. Two or more different treatment modalities had been tried in all patients and had failed to achieve remission. After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volume covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours after surgery, the other 2 fractions on the first postoperative day. Thus, a total dose of 18 Gy in 3 fractions was administered within 36 hours after the resection. Results: The treatment was feasible in all patients. No procedure-related complications (eg, secondary infections) occurred. Nineteen patients had keloid-related symptoms before treatment like pain and pruritus; disappearance of symptoms was noticed in all patients after treatment. After a median follow-up of 29.4 months (range, 7.9-72.4 months), 2 keloid recurrences and 2 mildly hypertrophied scars were observed. The local control rate was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. Conclusions: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest that brachytherapy may be advantageous in the management of high-risk keloids or as salvage treatment for failure after external beam therapy.

  18. Low-Dose (10-Gy) Total Skin Electron Beam Therapy for Cutaneous T-Cell Lymphoma: An Open Clinical Study and Pooled Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kamstrup, Maria R., E-mail: mkam0004@bbh.regionh.dk [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Gniadecki, Robert [Department of Dermatology, Bispebjerg Hospital, University of Copenhagen, Copenhagen (Denmark); Iversen, Lars [Department of Dermatology, Aarhus University Hospital, Aarhus (Denmark); Skov, Lone [Department of Dermatology, Gentofte Hospital, University of Copenhagen, Copenhagen (Denmark); Petersen, Peter Meidahl [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Loft, Annika [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Specht, Lena [Department of Oncology and Hematology, Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-01

    Purpose: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. Methods and Materials: In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over <2.5 weeks, receiving a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. Results: The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (<1% skin involvement with patches or plaques) documented in 57% of the patients. Median duration of overall cutaneous response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. Conclusions: Low-dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT.

  19. Estimation of the {beta}+ dose to the embryo resulting from {sup 18}F-FDG administration during early pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Zanotti-Fregonara, P.; Trebossen, R.; Maroy, R. [CEA, DSV, I2BM, SHFJ, LIME, Orsay (France); Champion, C. [Univ Paul Verlaine Metz, Inst Phys, Lab Phys Mol et Collis, Metz (France); Hindie, E. [Univ Paris 07, IUH, Ecole Doctorale B2T, Paris (France); Hindie, E. [Hop St Louis, AP-HP, Nucl Med Serv, F-75475 Paris 10 (France)

    2008-07-01

    Although {sup 18}F-FDG examinations are widely used, data are lacking on the dose to human embryo tissues in cases of exposure in early pregnancy. Although the photon component can easily be estimated from available data on the pharmacokinetics of {sup 18}F-FDG in female organs and from phantom measurements (considering the uterus as the target organ), the intensity of embryo tissue uptake, which is essential for deriving the {beta}+ dose, is not known. We report the case of a patient who underwent {sup 18}F-FDG PET/CT for tumor surveillance and who was later found to have been pregnant at the time of the examination(embryo age, 8 wk). Methods: The patient received 320 MBq of {sup 18}F-FDG. Imaging started with an unenhanced CT scan 1 h after the injection, followed by PET acquisition. PET images were used to compute the total number of {beta}+ emissions in embryo tissues per unit of injected activity, from standardized uptake value (SUV) measurements corrected for partial-volume effects. A Monte Carlo track structure code was then used to derive the {beta}+ self-dose and the {beta}+ cross-dose from amniotic fluid. The photon and CT doses were added to obtain the final dose received by the embryo. Results: The mean SUV in embryo tissues was 2.7, after correction for the partial-volume effect. The mean corrected SUV of amniotic fluid was 1.1. Monte Carlo simulation showed that the {beta}+ dose to the embryo (self-dose plus cross-dose from amniotic fluid) was 1.8 E-2 mGy per MBq of injected {sup 18}F-FDG. Based on MIRD data for the photon dose to the uterus, the estimated photon dose to the embryo was 1.5 E-2 mGy/MBq. Thus, the specific {sup 18}F-FDG dose to the embryo was 3.3 E-2 mGy/MBq (10.6 mGy in this patient). The CT scan added a further 8.3 mGy. Conclusion: The dose to the embryo is 3.3 E-2 mGy/MBq of {sup 18}F-FDG. The {beta}+ dose contributes 55% of the total dose. This value is higher than previous estimates in late nonhuman-primate pregnancies. (authors)

  20. 85Kr management trade-offs: a perspective to total radiation dose commitment

    International Nuclear Information System (INIS)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for 85 Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether 85 Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person

  1. Total Dose Effects on Bipolar Integrated Circuits at Low Temperature

    Science.gov (United States)

    Johnston, A. H.; Swimm, R. T.; Thorbourn, D. O.

    2012-01-01

    Total dose damage in bipolar integrated circuits is investigated at low temperature, along with the temperature dependence of the electrical parameters of internal transistors. Bandgap narrowing causes the gain of npn transistors to decrease far more at low temperature compared to pnp transistors, due to the large difference in emitter doping concentration. When irradiations are done at temperatures of -140 deg C, no damage occurs until devices are warmed to temperatures above -50 deg C. After warm-up, subsequent cooling shows that damage is then present at low temperature. This can be explained by the very strong temperature dependence of dispersive transport in the continuous-time-random-walk model for hole transport. For linear integrated circuits, low temperature operation is affected by the strong temperature dependence of npn transistors along with the higher sensitivity of lateral and substrate pnp transistors to radiation damage.

  2. High Total Ionizing Dose and Temperature Effects on Micro- and Nano-electronic Devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Martinez, M.; Paillet, P.; Leray, J.L.; Marcandella, C.; Duhamel, O.; Raine, M.; Richard, N.; Girard, S.; Ouerdane, Y.; Boukenter, A.; Goiffon, V.; Magnan, P.; Andrieu, F.; Barraud, S.; Faynot, O.

    2013-06-01

    This paper investigates the vulnerability of several micro- and nano-electronic technologies to a mixed harsh environment including high total ionizing dose at MGy levels and high temperature. Such operating conditions have been revealed recently for several applications like new security systems in existing or future nuclear power plants, fusion experiments, or deep space missions. In this work, the competing effects already reported in literature of ionizing radiations and temperature are characterized in elementary devices made of MOS transistors from several technologies. First, devices are irradiated using a radiation laboratory X-ray source up to MGy dose levels at room temperature. Devices are grounded during irradiation to simulate a circuit which waits for a wake up signal, representing most of the lifetime of an integrated circuit operating in a harsh environment. Devices are then annealed at several temperatures to discuss the post-irradiation behavior and to determine whether an elevated temperature is an issue or not for circuit function in mixed harsh environments. (authors)

  3. Total Ionizing Dose effects in 130-nm commercial CMOS technologies for HEP experiments

    CERN Document Server

    Gonella, L; Silvestri, M; Gerardin, S; Pantano, D; Re, V; Manghisoni, M; Ratti, L; Ranieri, A

    2007-01-01

    The impact of foundry-to-foundry variability and bias conditions during irradiation on the Total Ionizing Dose (TID) response of commercial 130-nm CMOS technologies have been investigated for applications in High Energy Physics (HEP) experiments. n- and p-channel MOSFETs from three different manufacturers have been irradiated with X-rays up to more than 100 Mrad (SiO2). Even though the effects of TID are qualitatively similar, the amount of degradation is shown to vary considerably from foundry to foundry, probably depending on the processing of the STI oxide and/or doping profile in the substrate. The bias during irradiation showed to have a strong impact as well on the TID response, proving that exposure at worst case bias conditions largely overestimates the degradation a device may experience during its lifetime. Overall, our results increase the confidence that 130-nm CMOS technologies can be used in future HEP experiments even without Hardness-By-Design solutions, provided that constant monitoring of th...

  4. 85Kr management trade-offs: a perspective to total radiation dose commitment

    Energy Technology Data Exchange (ETDEWEB)

    Mellinger, P.J.; Hoenes, G.R.; Brackenbush, L.W.; Greenborg, J.

    1980-01-01

    Radiological consequences arising from the trade-offs for /sup 85/Kr waste management from possible nuclear fuel resource recovery activities have been investigated. The reference management technique is to release all the waste gas to the atmosphere where it is diluted and dispersed. A potential alternative is to collect, concentrate, package and submit the gas to long-term storage. This study compares the radiation dose commitment to the public and to the occupationally exposed work force from these alternatives. The results indicate that it makes little difference to the magnitude of the world population dose whether /sup 85/Kr is captured and stored or chronically released to the environment. Further, comparisons of radiation exposures (for the purpose of estimating health effects) at very low dose rates to very large populations with exposures to a small number of occupationally exposed workers who each receive much higher dose rates may be misleading. Finally, cost studies (EPA 1976 and DOE 1979a) show that inordinate amounts of money will be required to lower this already extremely small 80-year cumulative world population dose of 0.05 mrem/person (<0.001% of natural background radiation for the same time period).

  5. Quantitative analysis of biological responses to low dose-rate γ-radiation, including dose, irradiation time, and dose-rate

    International Nuclear Information System (INIS)

    Magae, J.; Furukawa, C.; Kawakami, Y.; Hoshi, Y.; Ogata, H.

    2003-01-01

    Full text: Because biological responses to radiation are complex processes dependent on irradiation time as well as total dose, it is necessary to include dose, dose-rate and irradiation time simultaneously to predict the risk of low dose-rate irradiation. In this study, we analyzed quantitative relationship among dose, irradiation time and dose-rate, using chromosomal breakage and proliferation inhibition of human cells. For evaluation of chromosome breakage we assessed micronuclei induced by radiation. U2OS cells, a human osteosarcoma cell line, were exposed to gamma-ray in irradiation room bearing 50,000 Ci 60 Co. After the irradiation, they were cultured for 24 h in the presence of cytochalasin B to block cytokinesis, cytoplasm and nucleus were stained with DAPI and propidium iodide, and the number of binuclear cells bearing micronuclei was determined by fluorescent microscopy. For proliferation inhibition, cells were cultured for 48 h after the irradiation and [3H] thymidine was pulsed for 4 h before harvesting. Dose-rate in the irradiation room was measured with photoluminescence dosimeter. While irradiation time less than 24 h did not affect dose-response curves for both biological responses, they were remarkably attenuated as exposure time increased to more than 7 days. These biological responses were dependent on dose-rate rather than dose when cells were irradiated for 30 days. Moreover, percentage of micronucleus-forming cells cultured continuously for more than 60 days at the constant dose-rate, was gradually decreased in spite of the total dose accumulation. These results suggest that biological responses at low dose-rate, are remarkably affected by exposure time, that they are dependent on dose-rate rather than total dose in the case of long-term irradiation, and that cells are getting resistant to radiation after the continuous irradiation for 2 months. It is necessary to include effect of irradiation time and dose-rate sufficiently to evaluate risk

  6. Poster - 43: Analysis of SBRT and SRS dose verification results using the Octavius 1000SRS detector

    Energy Technology Data Exchange (ETDEWEB)

    Cherpak, Amanda [Nova Scotia Cancer Centre, Nova Scotia Health Authority, Halifax, NS, Department of Radiation Oncology, Dalhousie University, Halifax, NS, Department of Physics and Atmospheric Sciences, Dalhousie University, Halifax, NS (Canada)

    2016-08-15

    Purpose: The Octavius 1000{sup SRS} detector was commissioned in December 2014 and is used routinely for verification of all SRS and SBRT plans. Results of verifications were analyzed to assess trends and limitations of the device and planning methods. Methods: Plans were delivered using a True Beam STx and results were evaluated using gamma analysis (95%, 3%/3mm) and absolute dose difference (5%). Verification results were analyzed based on several plan parameters including tumour volume, degree of modulation and prescribed dose. Results: During a 12 month period, a total of 124 patient plans were verified using the Octavius detector. Thirteen plans failed the gamma criteria, while 7 plans failed based on the absolute dose difference. When binned according to degree of modulation, a significant correlation was found between MU/cGy and both mean dose difference (r=0.78, p<0.05) and gamma (r=−0.60, p<0.05). When data was binned according to tumour volume, the standard deviation of average gamma dropped from 2.2% – 3.7% for the volumes less than 30 cm{sup 3} to below 1% for volumes greater than 30 cm{sup 3}. Conclusions: The majority of plans and verification failures involved tumour volumes smaller than 30 cm{sup 3}. This was expected due to the nature of disease treated with SBRT and SRS techniques and did not increase rate of failure. Correlations found with MU/cGy indicate that as modulation increased, results deteriorated but not beyond the previously set thresholds.

  7. Ionizing Radiation Effects on the Noise of 65 nm CMOS Transistors for Pixel Sensor Readout at Extreme Total Dose Levels

    CERN Document Server

    Re, V.; Manghisoni, M.; Riceputi, E.; Traversi, G.; Ratti, L.

    2018-01-01

    This paper is focused on the study of the noise performance of 65 nm CMOS transistors at extremely high total ionizing dose (TID) levels of the order of several hundreds of Mrad(SiO2). Noise measurements are reported and discussed, analyzing radiation effects on 1/ f noise and channel thermal noise. In nMOSFETs, up to 10 Mrad(SiO2), the experimental behavior is consistent with a damage mechanism mainly associ- ated with lateral isolation oxides, and can be modeled by parasitic transistors turning on after irradiation and contributing to the total noise of the device. At very high dose, these parasitic transistors tend to be turned off by negative charge accumulating in interface states and compensating radiation-induced positive charge building up inside thick isolation oxides. Effects associated with ionization and hydrogen transport in spacer oxides may become dominant at 600 Mrad(SiO2) and may explain the observed noise behavior at extremely high TID. The results of this analysis provide an understanding o...

  8. SU-E-T-515: Field-In-Field Compensation Technique Using Multi-Leaf Collimator to Deliver Total Body Irradiation (TBI) Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [The State University of New York at Buffalo (United States); Wang, IZ [The State University of New York at Buffalo (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2014-06-01

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been used conventionally to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern field-in-field (FIF) technique with the multi-leaf collimator (MLC) to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the FIF technique to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Treatment fields include one pair of opposed open large fields (collimator=45°) with a specific weighting and a succession of smaller fields (collimator=90°) each with their own weighting. The smaller fields are shaped by moving MLC to block the sections of the patient which have already received close to 100% of the prescribed dose. The weighting factors for each of these fields were calculated using the attenuation coefficient of the initial lead compensators and the separation of the patient in different positions in the axial plane. Results: Dose-volume histograms (DVH) were calculated for evaluating the FIF compensation technique. The maximum body doses calculated from the DVH were reduced from the non-compensated 179.3% to 148.2% in the FIF plans, indicating a more uniform dose with the FIF compensation. All calculated monitor units were well within clinically acceptable limits and exceeded those of the original lead compensation plan by less than 50 MU (only ~1.1% increase). Conclusion: MLC FIF technique for TBI will not significantly increase the beam on time while it can substantially reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.

  9. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  10. Feasibility study of helical tomotherapy for total body or total marrow irradiation

    International Nuclear Information System (INIS)

    Hui, Susanta K.; Kapatoes, Jeff; Fowler, Jack; Henderson, Douglas; Olivera, Gustavo; Manon, Rafael R.; Gerbi, Bruce; Mackie, T. R.; Welsh, James S.

    2005-01-01

    Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (±10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (±7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In

  11. High-dose, hyperfractionated, accelerated radiotherapy using a concurrent boost for the treatment of nonsmall cell lung cancer: unusual toxicity and promising early results

    International Nuclear Information System (INIS)

    King, Stephen C.; Acker, Jeffrey C.; Kussin, Peter S.; Marks, Lawrence B.; Weeks, Kenneth J.; Leopold, Kenneth A.

    1996-01-01

    Purpose: The treatment of nonsmall cell lung cancer (NSCLC) with conventional radiotherapy (RT) results in inadequate local tumor control and survival. We report results of a Phase II trial designed to treat patients with a significantly increased total dose administered in a reduced overall treatment time using a hyperfractionated, accelerated treatment schedule with a concurrent boost technique. Methods and Materials: A total of 49 patients with unresectable Stage IIIA/IIIB (38 patients) or medically inoperable Stage I/II (11 patients) NSCLC were prospectively enrolled in this protocol. Radiation therapy was administered twice daily, 5 days/week with > 6 h between each treatment. The primary tumor and adjacent enlarged lymph nodes were treated to a total dose of 73.6 Gy in 46 fractions of 1.6 Gy each. Using a concurrent boost technique, electively irradiated nodal regions were simultaneously treated with a dose of 1.25 Gy/fraction for the first 36 fractions to a total dose of 45 Gy. Results: Median survival for the entire group of 49 patients is 15.3 months. Actuarial survival at 2 years is 46%: 60% for 11 Stage I/II patients, 55% for 21 Stage IIIA patients, and 26% for 17 Stage IIIB patients. The actuarial rate of freedom from local progression at 2 years is 64% for the entire group of 49 patients: 62% for Stage I/II patients, 70% for Stage IIIA patients, and 55% for Stage IIIB patients. Patients who underwent serial bronchoscopic reevaluation (4 Stage I/II, 8 Stage IIIA, and 6 Stage IIIB) have an actuarial rate of local control of 71% at 2 years. The median total treatment time was 32 days. Nine of 49 patients (18%) experienced Grade III acute esophageal toxicity. The 2-year actuarial risk of Grade III or greater late toxicity is 30%. The 2-year actuarial rate of severe-late pulmonary and skin-subcutaneous toxicity is 20% and 15%, respectively. Conclusion: This treatment regimen administers a substantially higher biologically effective dose compared with

  12. Dynamically accumulated dose and 4D accumulated dose for moving tumors

    International Nuclear Information System (INIS)

    Li Heng; Li Yupeng; Zhang Xiaodong; Li Xiaoqiang; Liu Wei; Gillin, Michael T.; Zhu, X. Ronald

    2012-01-01

    Purpose: The purpose of this work was to investigate the relationship between dynamically accumulated dose (dynamic dose) and 4D accumulated dose (4D dose) for irradiation of moving tumors, and to quantify the dose uncertainty induced by tumor motion. Methods: The authors established that regardless of treatment modality and delivery properties, the dynamic dose will converge to the 4D dose, instead of the 3D static dose, after multiple deliveries. The bounds of dynamic dose, or the maximum estimation error using 4D or static dose, were established for the 4D and static doses, respectively. Numerical simulations were performed (1) to prove the principle that for each phase, after multiple deliveries, the average number of deliveries for any given time converges to the total number of fractions (K) over the number of phases (N); (2) to investigate the dose difference between the 4D and dynamic doses as a function of the number of deliveries for deliveries of a “pulsed beam”; and (3) to investigate the dose difference between 4D dose and dynamic doses as a function of delivery time for deliveries of a “continuous beam.” A Poisson model was developed to estimate the mean dose error as a function of number of deliveries or delivered time for both pulsed beam and continuous beam. Results: The numerical simulations confirmed that the number of deliveries for each phase converges to K/N, assuming a random starting phase. Simulations for the pulsed beam and continuous beam also suggested that the dose error is a strong function of the number of deliveries and/or total deliver time and could be a function of the breathing cycle, depending on the mode of delivery. The Poisson model agrees well with the simulation. Conclusions: Dynamically accumulated dose will converge to the 4D accumulated dose after multiple deliveries, regardless of treatment modality. Bounds of the dynamic dose could be determined using quantities derived from 4D doses, and the mean dose

  13. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT

    International Nuclear Information System (INIS)

    Rampado, Osvaldo; Giglioli, Francesca Romana; Rossetti, Veronica; Ropolo, Roberto; Fiandra, Christian; Ragona, Riccardo

    2016-01-01

    Purpose: The aim of this study was to evaluate various approaches for assessing patient organ doses resulting from radiotherapy cone-beam CT (CBCT), by the use of thermoluminescent dosimeter (TLD) measurements in anthropomorphic phantoms, a Monte Carlo based dose calculation software, and different dose indicators as presently defined. Methods: Dose evaluations were performed on a CBCT Elekta XVI (Elekta, Crawley, UK) for different protocols and anatomical regions. The first part of the study focuses on using PCXMC software (PCXMC 2.0, STUK, Helsinki, Finland) for calculating organ doses, adapting the input parameters to simulate the exposure geometry, and beam dose distribution in an appropriate way. The calculated doses were compared to readouts of TLDs placed in an anthropomorphic Rando phantom. After this validation, the software was used for analyzing organ dose variability associated with patients’ differences in size and gender. At the same time, various dose indicators were evaluated: kerma area product (KAP), cumulative air-kerma at the isocenter (K_a_i_r), cone-beam dose index, and central cumulative dose. The latter was evaluated in a single phantom and in a stack of three adjacent computed tomography dose index phantoms. Based on the different dose indicators, a set of coefficients was calculated to estimate organ doses for a range of patient morphologies, using their equivalent diameters. Results: Maximum organ doses were about 1 mGy for head and neck and 25 mGy for chest and pelvis protocols. The differences between PCXMC and TLDs doses were generally below 10% for organs within the field of view and approximately 15% for organs at the boundaries of the radiation beam. When considering patient size and gender variability, differences in organ doses up to 40% were observed especially in the pelvic region; for the organs in the thorax, the maximum differences ranged between 20% and 30%. Phantom dose indexes provided better correlation with organ doses

  14. Automated extraction of radiation dose information from CT dose report images.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  15. Evaluation of Total Daily Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the Hospital

    Science.gov (United States)

    2016-05-20

    regular insulin has significantly increased in recent years. These patients are severely insulin resistant requiring high doses of insulin to achieve...on U-500 Insulin Admitted to the Hospital presented at SURF Conference, San Antonio, TX 20 May 201 6 with MDWI 41-108, and has been assigned local...59th CSPG/SGVU) C.201 4 . I 52d PROTOCOL TITLE Evaluation of Total Dai ly Dose and Glycemic Control for Patients on U-500 Insulin Admitted to the

  16. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  17. Biosphere transport and radiation dose calculations resulting from radioactive waste stored in deep salt formation (PACOMA-project)

    International Nuclear Information System (INIS)

    Jong, E.J. de; Koester, H.W.; Vries, W.J. de; Lembrechts, J.F.

    1990-03-01

    Parts are presented of the results of a safety-assessment study of disposal of medium and low level radioactive waste in salt formations in the Netherlands. The study concerns several disposal concepts for 2 kinds of salt formation, a deep dome and a shallow dome. 7 cases were studied with the same Dutch inventory and 1 with a reference inventory R, in order to compare results with those of other PACOMA participants. The total activity of the reference inventory R is 30 percent lower than the Dutch inventory, but some long living nuclides such as I-129, Np-237 and U-238 have a considerably higher activity. This reference inventor R has been combined with the disposal concept of mined cavities in a shallow salt dome. In each case. the released fraction of stored radio-nuclides moves gradually with water through the geosphere to the bio-sphere where it enters a river. River water is used for sprinkler irrigation and for drinking by man and livestock. The dispersal of the radionuclides into the biosphere is calculated with the BIOS program of the NRPB. Subroutines linked to the program add doses via different pathways to obtain a maximum individual dose, a collective dose and an integrated collective dose. This study presents results of these calculations. (author). 11 refs.; 39 figs.; 111 tabs

  18. Prediction of total dose effects on sub-micron process metal oxide semiconductor devices

    International Nuclear Information System (INIS)

    Kamimura, Hiroshi; Kato, Masataka.

    1991-01-01

    A method for correcting leakage currents is described to predict the radiation-induced threshold voltage shift of sub-micron MOSFETs. A practical model for predicting the leakage current generated by irradiation is also given on the basis of experimental results on 0.8-μm process MOSFETs. The constants in the threshold voltage shift model are determined from the 'true' I-V characteristic of the MOSFET, which is obtained by correction of leakage currents due to characteristic change of a parasitic transistor. In this way, the threshold voltage shift of the n-channel MOSFET irradiated at a low dose rate of 2 Gy(Si)/h was also calculated by using data from a high dose rate irradiation experiment (100 Gy(Si)/h, 5 h). The calculated result well represented the tendency of measured data on threshold voltage shift. The radiation-induced leakage current was considered to decay approximately in two exponential modes. The constants in this leakage current model were determined from the above high dose rate experiment. The response of leakage current predicted at a low dose rate of 2 Gy(Si)/h approximately agreed with that measured during and after irradiation. (author)

  19. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  20. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    International Nuclear Information System (INIS)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A

    2016-01-01

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm"2 size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  1. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  2. Impact of Drug Therapy, Radiation Dose, and Dose Rate on Renal Toxicity Following Bone Marrow Transplantation

    International Nuclear Information System (INIS)

    Cheng, Jonathan C.; Schultheiss, Timothy E.; Wong, Jeffrey Y.C.

    2008-01-01

    Purpose: To demonstrate a radiation dose response and to determine the dosimetric and chemotherapeutic factors that influence the incidence of late renal toxicity following total body irradiation (TBI). Methods and Materials: A comprehensive retrospective review was performed of articles reporting late renal toxicity, along with renal dose, fractionation, dose rate, chemotherapy regimens, and potential nephrotoxic agents. In the final analysis, 12 articles (n = 1,108 patients), consisting of 24 distinct TBI/chemotherapy conditioning regimens were included. Regimens were divided into three subgroups: adults (age ≥18 years), children (age <18 years), and mixed population (both adults and children). Multivariate logistic regression was performed to identify dosimetric and chemotherapeutic factors significantly associated with late renal complications. Results: Individual analysis was performed on each population subgroup. For the purely adult population, the only significant variable was total dose. For the mixed population, the significant variables included total dose, dose rate, and the use of fludarabine. For the pediatric population, only the use of cyclosporin or teniposide was significant; no dose response was noted. A logistic model was generated with the exclusion of the pediatric population because of its lack of dose response. This model yielded the following significant variables: total dose, dose rate, and number of fractions. Conclusion: A dose response for renal damage after TBI was identified. Fractionation and low dose rates are factors to consider when delivering TBI to patients undergoing bone marrow transplantation. Drug therapy also has a major impact on kidney function and can modify the dose-response function

  3. The role of total dose in conservative surgery and radiation therapy for early stage breast cancer: is there a critical level?

    Energy Technology Data Exchange (ETDEWEB)

    White, Julia; Brown, Douglas; Gustafson, Greg; Chen, Peter; Matter, Richard; Cook, Carla; Martinez, Alvaro; Vicini, Frank A

    1995-07-01

    Purpose: Over the past several years, it has been our standard policy after breast conserving surgery to treat the entire breast to 45-50 Gy followed by a supplemental boost dose to the tumor bed to a minimum of 60 Gy with standard fractionation. We reviewed patients who received < 60 Gy to the tumor bed to identify any differences in recurrence rates in the breast. Materials and Methods: From 1/1/75 through 12/31/87, 443 consecutive patients diagnosed with stage I and II breast cancer (unilateral) were treated with conservative surgery and radiation therapy (CSRT) at William Beaumont Hospital. All patients underwent at least an excisional biopsy and 268 (60%) patients were re-excised. An ipsilateral axillary lymph node dissection was performed on 420 patients (95%). All patients received whole breast irradiation to 45-50 Gy. A supplemental boost dose was delivered to the tumor bed with either an implant, electrons, or photons in 404 (91%) patients. Median follow-up of surviving patients is 88 months. Results: Thirty-three patients of the 443 have suffered a failure in the treated breast for a 5 and 10 yr actuarial rate of local recurrence of 5 and 10%, respectively. Evaluation by total dose to the tumor bed is as follows: The distribution of patient's respective histology, tumor size, hormonal status, age, re-excision status, and adjuvant systemic therapy was similar among the dose groups. On multivariate analysis (Cox), in addition to total dose to tumor bed (p=0.002), the only other factor which was significantly associated with local recurrence was patient age {<=} 35 (p=0.002). Conclusions: Patients who receive {<=} 50 Gy to the tumor bed without careful attention to excisional status are at a significantly higher risk of local failure. This underlies the importance of supplementing the tumor bed dose after whole breast radiation therapy in those patients whose status of excision is not definitely known.

  4. Intraoperative Low-Dose Ketamine Infusion Reduces Acute Postoperative Pain Following Total Knee Replacement Surgery: A Prospective, Randomized Double-Blind Placebo-Controlled Trial

    International Nuclear Information System (INIS)

    Pelin Cengiz, P.; Gokcinar, D.; Karabeyoglu, I.; Topcu, H.; Cicek, G. S.; Gogus, N.

    2014-01-01

    Objective: To evaluate the effect of intraoperative low-dose ketamine with general anesthesia on postoperative pain after total knee replacement surgery. Study Design: A randomized, double-blind comparative study. Place and Duration of Study: Ankara Numune Training and Research Hospital, Turkey, from January and June 2011. Methodology: Sixty adults undergoing total knee arthroplasty were enrolled in this study. The patients were randomly allocated into two groups of equal size to receive either racemic ketamine infusion (6.25 g/kg/minute) or the same volume of saline. A visual analogue scale (VAS) was used to measure each patient's level of pain at 1, 3, 6, 12, and 24 hours after surgery. Time to first analgesic request, postoperative morphine consumption and the incidence of side effects were also recorded. Results: Low-dose ketamine infusion prolonged the time to first analgesic request. It also reduced postoperative cumulative morphine consumption at 1, 3, 6, 12, and 24 hours postsurgery (p < 0.001). Postoperative VAS scores were also significantly lower in the ketamine group than placebo, at all observation times. Incidences of side effects were similar in both study groups. Conclusion: Intraoperative continuous low-dose ketamine infusion reduced pain and postoperative analgesic consumption without affecting the incidence of side effects. (author)

  5. Biological responses to low dose rate gamma radiation

    International Nuclear Information System (INIS)

    Magae, Junji; Ogata, Hiromitsu

    2003-01-01

    Linear non-threshold (LNT) theory is a basic theory for radioprotection. While LNT dose not consider irradiation time or dose-rate, biological responses to radiation are complex processes dependent on irradiation time as well as total dose. Moreover, experimental and epidemiological studies that can evaluate LNT at low dose/low dose-rate are not sufficiently accumulated. Here we analyzed quantitative relationship among dose, dose-rate and irradiation time using chromosomal breakage and proliferation inhibition of human cells as indicators of biological responses. We also acquired quantitative data at low doses that can evaluate adaptability of LNT with statistically sufficient accuracy. Our results demonstrate that biological responses at low dose-rate are remarkably affected by exposure time, and they are dependent on dose-rate rather than total dose in long-term irradiation. We also found that change of biological responses at low dose was not linearly correlated to dose. These results suggest that it is necessary for us to create a new model which sufficiently includes dose-rate effect and correctly fits of actual experimental and epidemiological results to evaluate risk of radiation at low dose/low dose-rate. (author)

  6. Accelerated hyperfractionated hepatic irradiation in the management of patients with liver metastases: Results of the RTOG dose escalating protocol

    International Nuclear Information System (INIS)

    Russell, A.H.; Clyde, C.; Wasserman, T.H.; Turner, S.S.; Rotman, M.

    1993-01-01

    This study was prepared to address two objectives: (a) to determine whether progressively higher total doses of hepatic irradiation can prolong survival in a selected population of patients with liver metastases and (b) to refine existing concepts of liver tolerance for fractionated external radiation. One hundred seventy-three analyzable patients with computed tomography measurable liver metastases from primary cancers of the gastrointestinal tract were entered on a dose escalating protocol of twice daily hepatic irradiation employing fractions of 1.5 Gy separated by 4 hr or longer. Sequential groups of patients received 27 Gy, 30 Gy, and 33 Gy to the entire liver and were monitored for acute and late toxicities, survival, and cause of death. Dose escalation was implemented following survival of 10 patients at each dose level for a period of 6 months or longer without clinical or biochemical evidence of radiation hepatitis. The use of progressively larger total doses of radiation did not prolong median survival or decrease the frequency with which liver metastases were the cause of death. None of 122 patients entered at the 27 Gy and 30 Gy dose levels revealed clinical or biochemical evidence of radiation induced liver injury. Five of 51 patients entered at the 33 Gy level revealed clinical or biochemical evidence of late liver injury with an actuarial risk of severe (Grade 3) radiation hepatitis of 10.0% at 6 months, resulting in closure of the study to patient entry. The study design could not credibly establish a safe dose for hepatic irradiation, however, it did succeed in determining that 33 Gy in fractions of 1.5 Gy is unsafe, carrying a substantial risk of delayed radiation injury. The absence of apparent late liver injury at the 27 Gy and 30 Gy dose levels suggests that a prior clinical trial of adjuvant hepatic irradiation in patients with resected colon cancer may have employed an insufficient radiation dose (21 Gy) to fully test the question

  7. The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography

    Directory of Open Access Journals (Sweden)

    Toon Van Cauteren

    2017-01-01

    Full Text Available Objectives. To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR techniques on the iodine dose in coronary CTA. Methods. Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR, and contrast-to-noise ratio (CNR in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. Results. Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11, except for streak artifacts (p=0.02 which were considered to be more severe, although acceptable, with the 80 kVp protocol. Conclusions. Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.

  8. The carcinogenic risk of high dose total body irradiation in non-human primates

    International Nuclear Information System (INIS)

    Broerse, J.J.; Bartstra, R.W.; Bekkum, D.W. van; Hage, M.H. van der; Zurcher, C.; Zwieten, M.J. van; Hollander, C.F.

    2000-01-01

    High dose total body irradiation (TBI) in combination with chemotherapy, followed by rescue with bone marrow transplantation (BMT), is increasingly used for the treatment of haematological malignancies. With the increasing success of this treatment and its current introduction for treating refractory autoimmune diseases the risk of radiation carcinogenesis is of growing concern. Studies on turnout induction in non-human primates are of relevance in this context since the response of this species to radiation does not differ much from that in man. Since the early sixties, studies have been performed on acute effects in Rhesus monkeys and the protective action of bone marrow transplantation after irradiation with X-rays (average total body dose 6.8 Gy) and fission neutrons (average dose 3.4 Gy). Of those monkeys, which were irradiated and reconstituted with autologous bone marrow, 20 animals in the X-irradiated group and nine animals in the neutron group survived more than 3 years. A group of 21 non-irradiated Rhesus monkeys of a comparable age distribution served as controls. All animals were regularly screened for the occurrence of neoplasms. Complete necropsies were performed after natural death or euthanasia. At post-irradiation intervals of 4-21 years an appreciable number of tumours was observed. In the neutron irradiated group eight out of nine animals died with one or more malignant tumours. In the X-irradiated group this fraction was 10 out of 20. The tumours in the control group, in seven out of the 21 animals, appeared at much older a-e compared with those in the irradiated cohorts. The histogenesis of the tumours was diverse with a preponderance of renal carcinoma, sarcomas among which osteosarcormas, and malignant glomus tumours in the irradiated groups. When corrected for competing risks, the carcinogenic risk of TBI in the Rhesus monkeys is similar to that derived from the studies of the Japanese atomic bomb survivors. The increase of the risk by a

  9. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.

  10. The role of low-dose total body irradiation in treatment of non-Hodgkin's lymphoma: a new look at an old method

    International Nuclear Information System (INIS)

    Safwat, A.

    2000-01-01

    The use of low-dose total body irradiation (LTBI) in treatment of lymphomatous malignancies dates back to the 1920s. The usual practice was to give very low individual TBI fraction sizes (0. 1-0.25 Gy) several times a week to a total dose of 1.5-2 Gy. Despite this very low total dose, LTBI could induce long term remissions and was always as effective as the chemotherapy to which it was compared. In modem radiotherapy, LTBI is still a valid option in treatment of chronic lymphocytic leukaemia (CLL) and the advanced stages of indolent low-grade non-Hodgkin's lymphoma (NHL). Its use in the early stages of low-grade NHL is under investigation in a large multi-institutional trial. The efficacy of LTBI is believed to stem from three mechanisms, namely; immune-enhancement, induction of apoptosis, and the intrinsic hypersensitivity to low-radiation doses demonstrated in many cell lines and tumour systems. Thus, LTBI seems to provide 'alternative' mechanisms of action against cancer cells. This should encourage researchers to explore strategies that integrate LTBI in new and innovative experimental treatment protocols that explore the possible synergism between LTBI and chemotherapy, biological response modifiers and/or immunotherapy. The increased incidence of secondary leukaemia that occurs when LTBI is combined with alkylating agents and/or total lymphoid irradiation should be kept in mind when designing such protocols as it may limit the use of LTBI in highly curable diseases and young patients in whom long survival is expected. (author)

  11. SU-E-T-92: Achieving Desirable Lung Doses in Total Body Irradiation Based On in Vivo Dosimetry and Custom Tissue Compensation

    International Nuclear Information System (INIS)

    Cui, G; Shiu, A; Zhou, S; Cui, J; Ballas, L

    2015-01-01

    Purpose: To achieve desirable lung doses in total body irradiation (TBI) based on in vivo dosimetry and custom tissue compensation. Methods: The 15 MV photon beam of a Varian TrueBeam STx linac was used for TBI. Patients were positioned in the lateral decubitus position for AP/PA treatment delivery. Dose was calculated using the midpoint of the separation distance across the patient’s umbilicus. Patients received 200 cGy twice daily for 3 days. The dose rate at the patient’s midplane was approximately 10 cGy/min. Cerrobend blocks with a 5-HVL thickness were used for the primary lung shielding. A custom styrofoam holder for rice-flour filled bags was created based on the lung block cutouts. This was used to provide further lung shielding based on in vivo dose measurements. Lucite plates and rice-flour bags were placed in the head, neck, chest, and lower extremity regions during the treatment to compensate for the beam off-axis output variations. Two patients were included in the study. Patients 1 and 2 received a craniospinal treatment (1080 cGy) and a mediastinum treatment (2520 cGy), respectively, before the TBI. During the TBI nanoDot dosimeters were placed on the patient skin in the forehead, neck, umbilicus, and lung regions for dose monitoring. The doses were readout immediately after the treatment. Based on the readings, fine tuning of the thickness of the rice-flour filled bags was exploited to achieve the desirable lung doses. Results: For both patients the mean lung doses, which took into consideration all treatments, were controlled within 900 +/−10% cGy, as desired. Doses to the forehead, neck, and umbilicus were achieved within +/−10% of the prescribed dose (1200 cGy). Conclusion: A reliable and robust method was developed to achieve desirable lung doses and uniform body dose in TBI based on in vivo dosimetry and custom tissue compensator

  12. SU-E-T-92: Achieving Desirable Lung Doses in Total Body Irradiation Based On in Vivo Dosimetry and Custom Tissue Compensation

    Energy Technology Data Exchange (ETDEWEB)

    Cui, G; Shiu, A; Zhou, S; Cui, J; Ballas, L [Univ Southern California, Los Angeles, CA (United States)

    2015-06-15

    Purpose: To achieve desirable lung doses in total body irradiation (TBI) based on in vivo dosimetry and custom tissue compensation. Methods: The 15 MV photon beam of a Varian TrueBeam STx linac was used for TBI. Patients were positioned in the lateral decubitus position for AP/PA treatment delivery. Dose was calculated using the midpoint of the separation distance across the patient’s umbilicus. Patients received 200 cGy twice daily for 3 days. The dose rate at the patient’s midplane was approximately 10 cGy/min. Cerrobend blocks with a 5-HVL thickness were used for the primary lung shielding. A custom styrofoam holder for rice-flour filled bags was created based on the lung block cutouts. This was used to provide further lung shielding based on in vivo dose measurements. Lucite plates and rice-flour bags were placed in the head, neck, chest, and lower extremity regions during the treatment to compensate for the beam off-axis output variations. Two patients were included in the study. Patients 1 and 2 received a craniospinal treatment (1080 cGy) and a mediastinum treatment (2520 cGy), respectively, before the TBI. During the TBI nanoDot dosimeters were placed on the patient skin in the forehead, neck, umbilicus, and lung regions for dose monitoring. The doses were readout immediately after the treatment. Based on the readings, fine tuning of the thickness of the rice-flour filled bags was exploited to achieve the desirable lung doses. Results: For both patients the mean lung doses, which took into consideration all treatments, were controlled within 900 +/−10% cGy, as desired. Doses to the forehead, neck, and umbilicus were achieved within +/−10% of the prescribed dose (1200 cGy). Conclusion: A reliable and robust method was developed to achieve desirable lung doses and uniform body dose in TBI based on in vivo dosimetry and custom tissue compensator.

  13. A method for total body irradiation

    International Nuclear Information System (INIS)

    Yasukochi, Hiroshi; Higashi, Shizuka; Okuhata, Yoshitaka; Lee, Keiichi; Ishioka, Kuniaki; Murakami, Koji; Nagai, Jun; Kuniyasu, Yoshio

    1988-01-01

    In these two years, we have treated four infant patients of acute leukemia by Cobalt-60 total body irradiation and bone marrow transplantation. During total body irradiation, thermoluminescence dosimeters were attached to the skin of patients. For four patients, nine dosimetries were performed. Reliability of this method was examined by phantom experiment. Every irradiation for the patient per fraction was 2.4 Gy, that is, 60 cGy for each four positions, right decubitus A-P and PA directions and left decubitus A-P and PA directions under aseptic circumstances. Radiation dose was uniform by this technique for each patient, and average determined dose for surface of the patients was between 87 % and 106 % compared with the air dose of the center of aseptic space (wagon). As the result, we suggest that this method is suitable for the total body irradiation of acute leukemia of infant. (author)

  14. Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign

    International Nuclear Information System (INIS)

    Nikodemová, D.; Brodecki, M.; Carinou, E.; Domienik, J.; Donadille, L.; Koukorava, C.; Krim, S.; Ruiz-López, N.; Sans-Merce, M.; Struelens, L.; Vanhavere, F.; Zaknoune, R.

    2011-01-01

    The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10–12% increase in the number of IR examinations every year (). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed. The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses. -- Highlights: ► We present a set of data on extremity doses for staff in selected interventional radiology procedures. ► We studied the influence of different parameters. ► The measured doses are analyzed according to the operators skill,his position during work, tube configuration, etc. ► Maximum doses recorded for all types of embolisation, in all

  15. SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, H; Kumar, S; Sarkar, B; Ganesh, T; Giri, U; Jassal, K; Rathinamuthu, S; Gulia, G; Gopal, V; Mohanti, B; Munshi, A [Fortis Memorial Research Institute, Gurgaon, Haryana (India)

    2016-06-15

    Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

  16. Natural radiation dose to Gammarus from Hudson river

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Wrenn, M.E.; Eisenbud, M.

    1979-01-01

    The purpose of this investigation is to evaluate the natural radiation dose rate to whole body and components of the Gammarus species, a zooplankton which occurs in the Hudson River among other places, and to compare the results with the upper limits of dose rates from man-made sources. The alpha dose rates to the exoskeleton and soft tissues are about 10 times the average alpha dose rate to the whole body, assuming uniform distribution of 226 Ra. The natural alpha radiation dose rate to Gammarus represents only about 5% of the total natural dose to the organism, i.e., 492 mrad/yr. The external dose rate due to 40 K, 238 U plus daughters and 232 Th plus daughters accumulated in the sediments comprise 91% of that total natural dose rate, the remaining percentage being due to natural internal beta emitters and cosmic radiation. Man-made sources can cause an external dose rate up to 224 mrad/yr, which comprises roughly 1/3 of the total dose rate (up to 716 mrad/yr; natural plus man-made) to the Gammarus of Hudson River in front of Indian Point Nuclear Power Station. However, in terms of dose-equivalent the natural sources of radiation would contribute more than 75% of the total dose to Gammarus

  17. Results of large scale thyroid dose reconstruction in Ukraine

    International Nuclear Information System (INIS)

    Likhtarev, I.; Sobolev, B.; Kairo, I.; Tabachny, L.; Jacob, P.; Proehl, G.; Goulko, G.

    1996-01-01

    In 1993, the Ukrainian Ministry on Chernobyl Affairs initiated a large scale reconstruction of thyroid exposures to radioiodine after the Chernobyl accident. The objective was to provide the state policy on social compensations with a scientific background. About 7000 settlements from five contaminated regions have gotten certificates of thyroid exposure since then. Certificates contain estimates of the average thyroid dose from 131 I for seven age groups. The primary dose estimates used about 150000 direct measurements of the 131 I activity in the thyroid glands of inhabitants from Chernigiv, Kiev, Zhytomyr, and also Vinnytsa regions. Parameters of the assumed intake function were related to environmental and questionnaire data. The dose reconstruction for the remaining territory was based on empirical relations between intake function parameters and the 137 Cs deposition. The relationship was specified by the distance and the direction to the Chernobyl Nuclear Power Plant. The relations were first derived for territories with direct measurements and then they were spread on other areas using daily iodine releases and atmospheric transportation routes. The results of the dose reconstruction allowed to mark zones on the territory of Ukraine according to the average levels of thyroid exposures. These zones underlay a policy of post-accidental health care and social compensations. Another important application of the thyroid dose reconstruction is the radiation risk assessment of thyroid cancer among people exposed during childhood due to the Chernobyl accident

  18. SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

    Energy Technology Data Exchange (ETDEWEB)

    Cvetkovic, D; Zhang, P; Wang, B; Chen, L; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

  19. Radiation doses to patients in radiodiagnostic in five Spanish hospitals. First results

    International Nuclear Information System (INIS)

    Grupo Aula Salinas

    1995-01-01

    We present the first results obtained from a study of radiation doses received by patients in diagnostic radiology in real examinations performed with a transmission camera. The study is being carried out in several Spanish hospitals and their dependent specialist outpatient centres where a quality control programme is being applied. The hospitals have over 4,600 beds and attend a population of over 2 million. The dose-area product was measured and the patient surface dose was calculated from it. Median values are presented for both parameters for a number of simple frequently-performed explorations. For most of these, the reference surface-dose values recommended by the C.E.C. are available. Although the corresponding assessment of image quality has not yet been performed, the results indicate that recommendations are generally being satisfied. However, the lack of correlation in the variation of the two values leads us to conclude that use of a single parameter to indicate the dose received by patients is inadequate. 4 refs

  20. Patient dose assessment in various Interventional radiology and cardiology procedures in Algeria (IAEA regional project results)

    International Nuclear Information System (INIS)

    Khelassi-Toutaoui, Nadia; Merad, Ahmed; Toutaoui, A.E.K.; Bairi, Souad

    2008-01-01

    Full text: Purpose: To evaluate patient doses in Interventional Radiology (IR) and Cardiology (IC) procedures in Algeria, within the framework of an International Atomic Energy Agency (IAEA) regional project on radiation protection of patients and medical exposure control (RAF 9033). Materials and Methods: Three public hospitals (CHU Bab el Oued, CHU Parnet and CHU Mustapha) and one specialised Cardiology Service (Clinique Maouche) were chosen for the study. For Maximum Skin Dose (MSD) evaluation, gafchromic films XR type R were used, placed on patient's back before the procedure. The Dose Area Product (DAP) and MSD were measured in 57 IR and IC procedures, either diagnostic or therapeutic. Results: The results revealed large variations in MSD (0.06-3.3 Gy) and DAP (5.5-332 mGycm 2 ). Mean MSD was 0.227 Gy in cerebral angiography, 0.202 Gy in coronary angiography, 1.162 Gy in Percutaneus Transluminal Coronary Angioplasty (PTCA) and 0.128 in abdominal angiography. The correlation of DAP and MSD was significant (r = 0.7). The correlation was DAP and fluoroscopy time was also significant (r = 0.8). Conclusion: The highest MSD values were found in PTCA which is a therapeutic procedure. Two PTCAs out of the 57 procedures measured in total had MSD over the threshold of 2 Gy for deterministic effects (MSD 1 = 3.0 Gy and MSD 2 3.3 Gy). The large variations in MSD reveal the need to continuously monitor patient doses in IR and IC procedures with special emphasis in PTCA procedure. (author)

  1. TU-F-CAMPUS-T-01: Dose and Energy Spectra From Neutron Induced Radioactivity in Medical Linear Accelerators Following High Energy Total Body Irradiation

    International Nuclear Information System (INIS)

    Keehan, S; Taylor, M; Franich, R; Smith, R; Dunn, L; Kron, T

    2015-01-01

    Purpose: To assess the risk posed by neutron induced activation of components in medical linear accelerators (linacs) following the delivery of high monitor unit 18 MV photon beams such as used in TBI. Methods: Gamma spectroscopy was used to identify radioisotopes produced in components of a Varian 21EX and an Elekta Synergy following delivery of photon beams. Dose and risk estimates for TBI were assessed using dose deliveries from an actual patient treatment. A 1 litre spherical ion chamber (PTW, Germany) has been used to measure the dose at the beam exit window and at the total body irradiation (TBI) treatment couch following large and small field beams with long beam-on times. Measurements were also made outside of the closed jaws to quantify the benefit of the attenuation provided by the jaws. Results: The radioisotopes produced in the linac head have been identified as 187 W, 56 Mn, 24 Na and 28 Al, which have half-lives from between 2.3 min to 24 hours. The dose at the beam exit window following an 18 MV 2197 MU TBI beam delivery was 12.6 µSv in ten minutes. The dose rate at the TBI treatment couch 4.8 m away is a factor of ten lower. For a typical TBI delivered in six fractions each consisting of four beams and an annual patient load of 24, the annual dose estimate for a staff member at the treatment couch for ten minutes is 750 µSv. This can be further reduced by a factor of about twelve if the jaws are closed before entering the room, resulting in a dose estimate of 65 µSv. Conclusion: The dose resulting from the activation products for a representative TBI workload at our clinic of 24 patients per year is 750 µSv, which can be further reduced to 65 µSv by closing the jaws

  2. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  3. Radiobiological basis of total body irradiation with different dose rate and fractionation: repair capacity of hemopoietic cells

    International Nuclear Information System (INIS)

    Song, C.W.; Kim, T.H.; Khan, F.M.; Kersey, J.H.; Levitt, S.H.

    1981-01-01

    Total body irradiation (TBI) followed by bone marrow transplantation is being used in the treatment of malignant or non-malignant hemopoietic disorders. It has been believed that the ability of hemopoietic cells to repair sublethal radiation damage is negligible. Therefore, several schools of investigators suggested that TBI in a single exposure at extremely low dose rate (5 rad/min) over several hours, or in several fractions in 2-3 days, should yield a higher therapeutic gain, as compared with a single exposure at a high dose rate (26 rad/min). We reviewed the existing data in the literature, in particular, the response of hemopoietic cells to fractionated doses of irradiation and found that the repair capacity of both malignant and non-malignant hemopoietic cells might be greater than has been thought. It is concluded that we should not underestimate the ability of hemopoietic cells to repair sublethal radiation damage in using TBI

  4. Doses in pediatric patients undergoing chest and abdomen CT examinations. Preliminary results

    International Nuclear Information System (INIS)

    Jornada, Tiago S.; Silva, Teogenes A. da

    2011-01-01

    Computed tomography (CT) is a non-invasive method of image production that imparts significant doses to a patient, it is expected that pediatric CT examinations will increase the risk of induced cancer in children. In this study the effective doses in a five year-old child submitted to chest or abdomen CT scans were assessed for comparison purposes. The CTEXPO computed program was used with data from routine protocols of a 0 to 13 year-old children in two public hospitals in Belo Horizonte. Hospital A used a Siemens Dual-Slice unit with 80 kV, 41 mA and pitch 2 for chest or abdomen; hospital B used a Multislice GE unit with 120 kV, 45 mA and pitch 1 for chest and 120 kV, 55 mA. and pitch 1 for abdomen. Results of effective doses in a five year-old child were 1.7 and 1.0 mSv in hospital A and 9.1 and 7.2 mSv in hospital B, for chest and abdomen, respectively. Results were compared to the reference effective doses of 7.2 and 5.0 mSv for chest and abdomen respectively that were derived from the air kerma length product values given in ICRP publication 87. Results of hospital A showed that low dose exposures also can be achieved in CT scans of children. Results showed that even a hospital with a modern facility (hospital B) can provided doses higher than reference values if protocols are not adjusted for children. Preliminary results suggested that there is a room for optimizing children exposure submitted to CT scans. (author)

  5. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  6. SPE dose prediction using locally weighted regression

    International Nuclear Information System (INIS)

    Hines, J. W.; Townsend, L. W.; Nichols, T. F.

    2005-01-01

    When astronauts are outside earth's protective magnetosphere, they are subject to large radiation doses resulting from solar particle events (SPEs). The total dose received from a major SPE in deep space could cause severe radiation poisoning. The dose is usually received over a 20-40 h time interval but the event's effects may be mitigated with an early warning system. This paper presents a method to predict the total dose early in the event. It uses a locally weighted regression model, which is easier to train and provides predictions as accurate as neural network models previously used. (authors)

  7. SPE dose prediction using locally weighted regression

    International Nuclear Information System (INIS)

    Hines, J. W.; Townsend, L. W.; Nichols, T. F.

    2005-01-01

    When astronauts are outside Earth's protective magnetosphere, they are subject to large radiation doses resulting from solar particle events. The total dose received from a major solar particle event in deep space could cause severe radiation poisoning. The dose is usually received over a 20-40 h time interval but the event's effects may be reduced with an early warning system. This paper presents a method to predict the total dose early in the event. It uses a locally weighted regression model, which is easier to train, and provides predictions as accurate as the neural network models that were used previously. (authors)

  8. Recent advances in understanding total-dose effects in bipolar transistors

    International Nuclear Information System (INIS)

    Schrimpf, R.D.

    1996-01-01

    Gain degradation in irradiated bipolar transistors can be a significant problem, particularly in linear integrated circuits. In many bipolar technologies, the degradation is greater for irradiation at low dose rates than it is for typical laboratory dose rates. Ionizing radiation causes the base current in bipolar transistors to increase, due to the presence of net positive charge in the oxides covering sensitive device areas and increases in surface recombination velocity. Understanding the mechanisms responsible for radiation-induced gain degradation in bipolar transistors is important in developing appropriate hardness assurance methods. This paper reviews recent modeling and experimental work, with the emphasis on low-dose-rate effects. A promising hardness assurance method based on irradiation at elevated temperatures is described

  9. The evaluation of a modified technique of Total Body Irradiation in respect of treatment results and toxicity

    International Nuclear Information System (INIS)

    Skowronska-Gardas, A.; Dabrowski, R.; Pedziwiatr, K.

    2006-01-01

    Total body irradiation (TBI) is a well established part of the conditioning regimen prior to bone marrow transplantation (BMT). Numerous different techniques are used and every center elaborates own solutions. The aim of our study to present the method of TBI developed in our department, and to discuss the results of treatment with respect of early and late toxicity. Between 11.2000 and 08.2004, 23 patients were with fractionated TBI at the Department of Radiotherapy of the M. Sklodowska-Curie Memorial Cancer Center and Institute of Oncology in Warsaw (MSCMCC). Conditioning chemotherapy and BMT were performed in different hematological departments. All patients were irradiated with a total midline dose of 12 Gy in 6 fractions over 3 consecutive days. Doses to the lung did not exceed 11 Gy. The TBI method used in our department was evaluated over a few years. The following modifications have been introduced to the previously applied technique: change of photon energy 6 MV to 15 MV; increase of lung dose from 9 Gy to 11 Gy; the use of an individual bolus as a lung compensator in lateral fields; more frequent boost irradiation of the mediastinum and legs with small fields; calculations of Monitor Units based on dosimetric data. Boost irradiation of chest wall with electrons been abandoned. Median follow up was 12 months. Up till now, 17/23 patients are alive, of these 16 with no relapse. Immediate toxicity was low. Early complications were observed during the first 6 months after BMT in 11 patients. In the case of 4 patients these complications were fatal. Late complications were observed in 10 patients, including chronic GVHD and hormone disturbance. Only one patient had developed the first symptoms of cataract. In one case Lhermitte's syndrome was observed. One patient died due to liver insufficiency. The results of treatment and the complications rates in patients treated with TBI at our department are consistent with those published in literature. We conclude that

  10. Total-dose radiation-induced degradation of thin film ferroelectric capacitors

    International Nuclear Information System (INIS)

    Schwank, J.R.; Nasby, R.D.; Miller, S.L.; Rodgers, M.S.; Dressendorfer, P.V.

    1990-01-01

    Thin film PbZr y Ti 1-y O 3 (PZT) ferroelectric memories offer the potential for radiation-hardened, high-speed nonvolatile memories with good retention and fatigue properties. In this paper we explore in detail the radiation hardness of PZT ferroelectric capacitors. Ferroelectric capacitors were irradiated using x-ray and Co-60 sources to dose levels up to 16 Mrad(Si). The capacitors were characterized for their memory properties both before and after irradiation. The radiation hardness was process dependent. Three out of four processes resulted in capacitors that showed less than 30% radiation-induced degradation in retained polarization charge and remanent polarization after irradiating to 16 Mrad(Si). On the other hand, one of the processes showed significant radiation-induced degradation in retained polarization charge and remanent polarization at dose levels above 1 Mrad(Si). The decrease in retained polarization charge appears to be due to an alteration of the switching characteristics of the ferroelectric due to changes in the internal fields. The radiation-induced degradation is recoverable by a postirradiation biased anneal and can be prevented entirely if devices are cycled during irradiation. The authors have developed a model to simulate the observed degradation

  11. Radiation therapy in the management of symptomatic bone metastases: the effect of total dose and histology on pain relief and response duration

    International Nuclear Information System (INIS)

    Arcangeli, Giorgio; Giovinazzo, Giuseppe; Saracino, Biancamaria; D'Angelo, Luciano; Giannarelli, Diana; Arcangeli, Giancarlo; Micheli, Adriana

    1998-01-01

    Purpose: In order to better define variables and factors that may influence the pain response to radiation, and to look for a radiation regimen that can assure the highest percentage and the longest duration of pain relief, we performed a prospective, although not randomized, study on patients with bone metastases from various primary sites. Methods and Materials: From December 1988 to March 1994, 205 patients with a total of 255 solitary or multiple bone metastases from several primary tumors were treated in our radiotherapy center with palliative intent. Irradiation fields were treated with three main fractionation schedules: (1) Conventional fractionation: 40-46 Gy/20-23 fractions in 5-5.5 weeks; (2) Short course: 30-36 Gy/10-12 fractions in 2-2.3 weeks; (3) Fast course: 8-28 Gy/1-4 consecutive fractions. Pain intensity was self-assessed by patients using a visual analogic scale graduated from 0 (no pain) to 10 (the strongest pain one can experience). Analgesic requirement was assessed by using a five-point scale, scoring both analgesic strength and frequency (0 = no drug or occasional nonopioids; 1 = Nonopioids once daily; 2 = Nonopioids more than once daily; 3 = Mild opioids (oral codeine, pentazocine, etc.), once daily; 4 = Mild opioids more than once daily; 5 = Strong opioids (morphine, meperidine, etc.). Complete pain relief meant the achievement of a score ≤ 2 in the pain scale or 0 in the analgesic requirement scale. Partial pain relief indicated a score of 3 to 4 or of 1 to 2 on the former and latter scale, respectively. Results: Total pain relief (complete + partial) was observed in 195 (76%) sites, in 158 of which (62%) a complete response was obtained. Metastases from NSC lung tumors appeared to be the least responsive among all primary tumors, with 46% complete pain relief in comparison to 65% and 83% complete relief in breast (p = 0.04) and in prostate metastases (p 0.002), respectively. A significant difference in pain relief was detected among

  12. Ladtap XL Version 2017: A Spreadsheet For Estimating Dose Resulting From Aqueous Releases

    Energy Technology Data Exchange (ETDEWEB)

    Minter, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jannik, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-15

    LADTAP XL© is an EXCEL© spreadsheet used to estimate dose to offsite individuals and populations resulting from routine and accidental releases of radioactive materials to the Savannah River. LADTAP XL© contains two worksheets: LADTAP and IRRIDOSE. The LADTAP worksheet estimates dose for environmental pathways including external exposure resulting from recreational activities on the Savannah River and internal exposure resulting from ingestion of water, fish, and invertebrates originating from the Savannah River. IRRIDOSE estimates offsite dose to individuals and populations from irrigation of foodstuffs with contaminated water from the Savannah River. In 2004, a complete description of the LADTAP XL© code and an associated user’s manual was documented in LADTAP XL©: A Spreadsheet for Estimating Dose Resulting from Aqueous Release (WSRC-TR-2004-00059) and revised input parameters, dose coefficients, and radionuclide decay constants were incorporated into LADTAP XL© Version 2013 (SRNL-STI-2011-00238). LADTAP XL© Version 2017 is a slight modification to Version 2013 with minor changes made for more user-friendly parameter inputs and organization, updates in the time conversion factors used within the dose calculations, and fixed an issue with the expected time build-up parameter referenced within the population shoreline dose calculations. This manual has been produced to update the code description, verification of the models, and provide an updated user’s manual. LADTAP XL© Version 2017 has been verified by Minter (2017) and is ready for use at the Savannah River Site (SRS).

  13. Low-Dose Total Skin Electron Beam Therapy as a Debulking Agent for Cutaneous T-Cell Lymphoma: An open-label prospective phase II study

    DEFF Research Database (Denmark)

    Kamstrup, M R; Lindahl, Lise Maria; Gniadecki, R

    2012-01-01

    Background: Total skin electron beam therapy (TSEBT) is a powerful treatment for cutaneous T-cell lymphomas (CTCL). Based on the occurrence of relapses with low radiation doses, doses of 30-36 Gy are commonly used but most patients still eventually relapse and repeat treatment courses are limited...... due to the cumulative toxicity. Complete response rates are about 60-90% for T2-4 stages with a 5-year relapse-free survival of 10-25% for stages IB-III. Objectives: To evaluate prospectively the efficacy of low-dose TSEBT (10 Gy) in terms of complete cutaneous response rate, overall response rate...... and response duration in CTCL. Methods: Ten patients with stage IB-IV mycosis fungoides (MF) were treated in an open-label manner with 4 fractions of 1 Gy/week TSEB to a total skin dose of 10 Gy. Treatment responses were assessed at 1 and 3 months after treatment and subsequently at least every 6 months...

  14. Results of comparative assessment of US and foreign nuclear power plant dose experience and dose reduction programs

    International Nuclear Information System (INIS)

    Baum, J.W.; Horan, J.R.; Dionne, B.J.

    1985-01-01

    The objectives of this study were to determine how collective dose equivalents at US nuclear power plants compare to those of other technically advanced countries, and to evaluate factors that contribute to the differences. Fifty Health Physicists and nuclear engineers from 10 countries met at BNL May 29 - June 1, 1984 to exchange information and hold discussions on ''Historical Dose Experience and Dose Reduction (ALARA) at Nuclear Power Plants''. Results of evaluation of data from this meeting and other data from recent publications are summarized. Based on data evaluated to date it is clear that US plants have higher collective dose equivalents per reactor and per MW-yr generated than most other countries. Factors which contribute to low doses include: 1) minimization of cobalt in primary system components exposed to water, 2) careful control of primary system oxygen and pH, 3) good primary system water purity to minimize corrosion product formation, 4) careful plant design, layout and component segregation and shielding, 5) management interest and commitment, 6) minimum number of workers and in-depth worker training, 7) use of special tools, and 8) plant standardization

  15. Cataract incidence after total-body irradiation

    International Nuclear Information System (INIS)

    Zierhut, D.; Lohr, F.; Schraube, P.; Huber, P.; Haas, R.; Hunstein, W.; Wannenmacher, M.

    1997-01-01

    Purpose: Aim of this retrospective study was to evaluate cataract incidence in a homogeneous group of patients after total-body irradiation followed by autologous bone marrow transplantation or peripheral blood stem cell transplantation. Method and Materials: Between 11/1982 and 6/1994 in total 260 patients received in our hospital total-body irradiation for treatment of haematological malignancy. In 1996-96 patients out of these 260 patients were still alive. 85 from these still living patients (52 men, 33 women) answered evaluable on a questionnaire and could be examined ophthalmologically. Median age of these patients was 38,5 years (15 - 59 years) at time of total-body irradiation. Radiotherapy was applied as hyperfractionated total-body irradiation with a median dose of 14,4 Gy in 12 fractions over 4 days. Minimum time between fractions was 4 hours, photons with a energy of 23 MeV were used, and the dose rate was 7 - 18 cGy/min. Results: Median follow-up is now 5,8 years (1,7 - 13 years). Cataract occurred in (28(85)) patients after a median time of 47 months (1 - 104 months). In 6 out of these 28 patients who developed a cataract, surgery of the cataract was performed. Whole-brain irradiation prior to total-body irradiation was more often in the group of patients developing a cataract (14,3%) vs. 10,7% in the group of patients without cataract. Conclusion: Cataract is a common side effect of total-body irradiation. Cataract incidence found in our patients is comparable to results of other centres using a fractionated regimen for total-body irradiation. The hyperfractionated regimen used in our hospital does obviously not result in a even lower cataract incidence. In contrast to acute and late toxicity in other organ/organsystems, hyperfractionation of total-body irradiation does not further reduce toxicity for the eye-lens. Dose rate may have more influence on cataract incidence

  16. The effect of total body irradiation dose and chronic graft-versus-host disease on leukaemic relapse after allogeneic bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Frassoni, F; Bacigalupo, A [Ospedale San Martino (Italy). Centro Trapianti Midollo Osseo; Scarpati, D [Univ. di Genova (Italy). Ist. di Radiologia; and others

    1989-10-01

    One-hundred and five patients undergoing allo-geneic bone marrow transplantation (BMT) for acute myeloid leukaemia (AML) (n=61) and chronic myeloid leukaemia (n=44) were analysed for risk factors associated with relapse. All patients received marrow from an HLA identical sibling after preparation with cyclophosphamide 120 mg/kg and total body irradiation (TBI) 330 cGy on each of the three days prior to transplantation. A multivariate Cox analysis indicated that a lower TBI dose (less than 990 cGy) was the most significant factor associated with relapse and the second most important factor associated with recurrence of leukaemia was the absence of chronic graft-versus-host-disease (cGvHD). Actuarial relapse incidence was 62%, 28% and 18% for patients with no, limited or extensive chronic GvHD respectively. However, chronic GvHD had no significant impact on survival. Combined stratification for TBI dose and cGvHD showed that the dose effect of TBI on relapse was evident both in patients with and without cGvHD. Chronic GvHD influenced the risk of relapse only in patients receiving less than 990 cGy. These results suggest that a higher dose of TBI, within this schedule, produced long-term disease-free survival in the majority of AMLs and CMLs. Minor radiobiological side effects were experienced, but a small reduction of the dose may significantly increase the risk of relapse. (author).

  17. The effect of total body irradiation dose and chronic graft-versus-host disease on leukaemic relapse after allogeneic bone marrow transplantation

    International Nuclear Information System (INIS)

    Frassoni, F.; Bacigalupo, A.; Scarpati, D.

    1989-01-01

    One-hundred and five patients undergoing allo-geneic bone marrow transplantation (BMT) for acute myeloid leukaemia (AML) (n=61) and chronic myeloid leukaemia (n=44) were analysed for risk factors associated with relapse. All patients received marrow from an HLA identical sibling after preparation with cyclophosphamide 120 mg/kg and total body irradiation (TBI) 330 cGy on each of the three days prior to transplantation. A multivariate Cox analysis indicated that a lower TBI dose (less than 990 cGy) was the most significant factor associated with relapse and the second most important factor associated with recurrence of leukaemia was the absence of chronic graft-versus-host-disease (cGvHD). Actuarial relapse incidence was 62%, 28% and 18% for patients with no, limited or extensive chronic GvHD respectively. However, chronic GvHD had no significant impact on survival. Combined stratification for TBI dose and cGvHD showed that the dose effect of TBI on relapse was evident both in patients with and without cGvHD. Chronic GvHD influenced the risk of relapse only in patients receiving less than 990 cGy. These results suggest that a higher dose of TBI, within this schedule, produced long-term disease-free survival in the majority of AMLs and CMLs. Minor radiobiological side effects were experienced, but a small reduction of the dose may significantly increase the risk of relapse. (author)

  18. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    International Nuclear Information System (INIS)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C.; Muenscher, A.; Blessmann, M.; Todorovic, M.; Tennstedt, P.

    2013-01-01

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  19. Xerostomia after radiotherapy. What matters - mean total dose or dose to each parotid gland?

    Energy Technology Data Exchange (ETDEWEB)

    Tribius, S.; Sommer, J.; Prosch, C.; Bajrovic, A.; Kruell, A.; Petersen, C. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Radiation Oncology; Muenscher, A. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Otorhinolaryngology and Head and Neck Surgery; Blessmann, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Oral and Maxillofacial Surgery; Todorovic, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Medical Physics; Tennstedt, P. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Martini-Clinic, Prostate Cancer Center

    2013-03-15

    Purpose: Xerostomia is a debilitating side effect of radiotherapy in patients with head and neck cancer. We undertook a prospective study of the effect on xerostomia and outcomes of sparing one or both parotid glands during radiotherapy for patients with squamous cell carcinoma of the head and neck. Methods and materials: Patients with locally advanced squamous cell carcinoma of the head and neck received definitive (70 Gy in 2 Gy fractions) or adjuvant (60-66 Gy in 2 Gy fractions) curative-intent radiotherapy using helical tomotherapy with concurrent chemotherapy if appropriate. Group A received < 26 Gy to the left and right parotids and group B received < 26 Gy to either parotid. Results: The study included 126 patients; 114 (55 in group A and 59 in group B) had follow-up data. There were no statistically significant differences between groups in disease stage. Xerostomia was significantly reduced in group A vs. group B (p = 0.0381). Patients in group A also had significantly less dysphagia. Relapse-free and overall survival were not compromised in group A: 2-year relapse-free survival was 86% vs. 72% in group B (p = 0.361); 2-year overall survival was 88% and 76%, respectively (p = 0.251). Conclusion: This analysis suggests that reducing radiotherapy doses to both parotid glands to < 26 Gy can reduce xerostomia and dysphagia significantly without compromising survival. Sparing both parotids while maintaining target volume coverage and clinical outcome should be the treatment goal and reporting radiotherapy doses delivered to the individual parotids should be standard practice. (orig.)

  20. Dose Escalation of Total Marrow Irradiation With Concurrent Chemotherapy in Patients With Advanced Acute Leukemia Undergoing Allogeneic Hematopoietic Cell Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Jeffrey Y.C., E-mail: jwong@coh.org [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California (United States); Forman, Stephen; Somlo, George [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States); Rosenthal, Joseph [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States); Department of Pediatrics, City of Hope National Medical Center, Duarte, California (United States); Liu An; Schultheiss, Timothy; Radany, Eric [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, California (United States); Palmer, Joycelynne [Department of Biostatistics, City of Hope National Medical Center, Duarte, California (United States); Stein, Anthony [Department of Hematology/Hematopoietic Cell Transplantation, City of Hope National Medical Center, Duarte, California (United States)

    2013-01-01

    Purpose: We have demonstrated that toxicities are acceptable with total marrow irradiation (TMI) at 16 Gy without chemotherapy or TMI at 12 Gy and the reduced intensity regimen of fludarabine/melphalan in patients undergoing hematopoietic cell transplantation (HCT). This article reports results of a study of TMI combined with higher intensity chemotherapy regimens in 2 phase I trials in patients with advanced acute myelogenous leukemia or acute lymphoblastic leukemia (AML/ALL) who would do poorly on standard intent-to-cure HCT regimens. Methods and Materials: Trial 1 consisted of TMI on Days -10 to -6, etoposide (VP16) on Day -5 (60 mg/kg), and cyclophosphamide (CY) on Day -3 (100 mg/kg). TMI dose was 12 (n=3 patients), 13.5 (n=3 patients), and 15 (n=6 patients) Gy at 1.5 Gy twice daily. Trial 2 consisted of busulfan (BU) on Days -12 to -8 (800 {mu}M min), TMI on Days -8 to -4, and VP16 on Day -3 (30 mg/kg). TMI dose was 12 (n=18) and 13.5 (n=2) Gy at 1.5 Gy twice daily. Results: Trial 1 had 12 patients with a median age of 33 years. Six patients had induction failures (IF), and 6 had first relapses (1RL), 9 with leukemia blast involvement of bone marrow ranging from 10%-98%, 5 with circulating blasts (24%-85%), and 2 with chloromas. No dose-limiting toxicities were observed. Eleven patients achieved complete remission at Day 30. With a median follow-up of 14.75 months, 5 patients remained in complete remission from 13.5-37.7 months. Trial 2 had 20 patients with a median age of 41 years. Thirteen patients had IF, and 5 had 1RL, 2 in second relapse, 19 with marrow blasts (3%-100%) and 13 with peripheral blasts (6%-63%). Grade 4 dose-limiting toxicities were seen at 13.5 Gy (stomatitis and hepatotoxicity). Stomatitis was the most frequent toxicity in both trials. Conclusions: TMI dose escalation to 15 Gy is possible when combined with CY/VP16 and is associated with acceptable toxicities and encouraging outcomes. TMI dose escalation is not possible with BU/VP16 due to

  1. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  2. First Results from the Online Radiation Dose Monitoring System in ATLAS experiment

    CERN Document Server

    Mandić, I; The ATLAS collaboration; Deliyergiyev, M; Gorišek, A; Kramberger, G; Mikuž, M; Franz, S; Hartert, J; Dawson, I; Miyagawa, P; Nicolas, L

    2011-01-01

    High radiation doses which will accumulate in components of ATLAS experiment during data taking will causes damage to detectors and readout electronics. It is therefore important to continuously monitor the doses to estimate the level of degradation caused by radiation. Online radiation monitoring system measures ionizing dose in SiO2 , displacement damage in silicon in terms of 1-MeV(Si) equivalent neutron fluence and fluence of thermal neutrons at several locations in ATLAS detector. In this paper design of the system, results of measurements and comparison of measured integrated doses and fluences with predictions from FLUKA simulation will be shown.

  3. Carbohydrate-to-insulin ratio is estimated from 300-400 divided by total daily insulin dose in type 1 diabetes patients who use the insulin pump.

    Science.gov (United States)

    Kuroda, Akio; Yasuda, Tetsuyuki; Takahara, Mitsuyoshi; Sakamoto, Fumie; Kasami, Ryuichi; Miyashita, Kazuyuki; Yoshida, Sumiko; Kondo, Eri; Aihara, Ken-ichi; Endo, Itsuro; Matsuoka, Taka-aki; Kaneto, Hideaki; Matsumoto, Toshio; Shimomura, Iichiro; Matsuhisa, Munehide

    2012-11-01

    To optimize insulin dose using insulin pump, basal and bolus insulin doses are widely calculated from total daily insulin dose (TDD). It is recommended that total daily basal insulin dose (TBD) is 50% of TDD and that the carbohydrate-to-insulin ratio (CIR) equals 500 divided by TDD. We recently reported that basal insulin requirement is approximately 30% of TDD. We therefore investigated CIR after adjustment of the proper basal insulin rate. Forty-five Japanese patients with type 1 diabetes were investigated during several weeks of hospitalization. The patients were served standard diabetes meals (25-30 kcal/kg of ideal body weight). Each meal omission was done to confirm basal insulin rate. Target blood glucose level was set at 100 and 150 mg/dL before and 2 h after each meal, respectively. After the basal insulin rate was fixed and target blood glucose levels were achieved, TBD, CIR, TDD, and their products were determined. Mean (±SD) blood glucose levels before and 2 h after meals were 121±47 and 150±61 mg/dL, respectively. TDD was 31.5±9.0 U, and TBD was 27.0±6.5% of TDD. CIR×TDD of breakfast was significantly lower than those of lunch and supper (288±73 vs. 408±92 and 387±83, respectively; Plunch and supper in type 1 diabetes patients. These results indicate that the insulin dose has been underestimated by using previously established calculations.

  4. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    International Nuclear Information System (INIS)

    Damkaer, D.M.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm -2 sub([DNA]) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm -2 sub([DNA]). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation. (orig.)

  5. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    Energy Technology Data Exchange (ETDEWEB)

    Damkaer, D.M.; Dey, D.B.; Heron, G.A.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm/sup -2/sub((DNA)) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm/sup -2/sub((DNA)). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation.

  6. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    International Nuclear Information System (INIS)

    Abdollahi, Hamid; Shiri, Isaac; Salimi, Yazdan; Sarebani, Maghsoud; Mehdinia, Reza; Deevband, Mohammad Reza; Mahdavi, Seied Rabi; Sohrabi, Ahmad; Bitarafan-Rajabi, Ahmad

    2016-01-01

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  7. Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahi, Hamid, E-mail: Hamid_rbp@yahoo.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Shiri, Isaac [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Salimi, Yazdan [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sarebani, Maghsoud; Mehdinia, Reza [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Deevband, Mohammad Reza [Biomedical Engineering and Medical Physics Department, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of); Mahdavi, Seied Rabi [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Radiation Biology Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Sohrabi, Ahmad [Department of Biostatistics, School of Public Health, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Bitarafan-Rajabi, Ahmad, E-mail: bitarafan@hotmail.com [Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Department of Nuclear Medicine, Rajaei Cardiovascular, Medical and Research Center, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2016-12-15

    Aims: The dose levels for Computed Tomography (CT) localization and attenuation correction of Single Photon Emission Computed Tomography (SPECT) are limited and reported as Volume Computed Tomography Dose Index (CTDIvol) and Dose-Length Product (DLP). This work presents CT dose estimation from Cardiac SPECT/CT based on new American Association of Physicists in Medicine (AAPM) Size Specific Dose Estimation (SSDE) parameter, effective dose, organ doses and also emission dose from nuclear issue. Material and methods: Myocardial perfusion SPECT/CT for 509 patients was included in the study. SSDE, effective dose and organ dose were calculated using AAPM guideline and Impact-Dose software. Data were analyzed using R and SPSS statistical software. Spearman-Pearson correlation test and linear regression models were used for finding correlations and relationships among parameters. Results: The mean CTDIvol was 1.34 mGy ± 0.19 and the mean SSDE was 1.7 mGy ± 0.16. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The mean ± SD of effective dose from emission, CT and total dose were 11.5 ± 1.4, 0.49 ± 0.11 and 12.67 ± 1.73 (mSv) respectively. The spearman test showed that correlation between body size and organ doses is significant except thyroid and red bone marrow. CTDIvol was strongly dependent on patient size, but SSDE was not. Emission dose was strongly dependent on patient weight, but its dependency was lower to effective diameter. Conclusion: The dose parameters including CTDIvol, DLP, SSDE, effective dose values reported here are very low and below the reference level. This data suggest that appropriate CT acquisition parameters in SPECT/CT localization and attenuation correction are very beneficial for patients and lowering cancer risks.

  8. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  9. Patient radiation doses in the most common interventional cardiology procedures in croatia: First results

    International Nuclear Information System (INIS)

    Brnic, Z.; Krpan, T.; Faj, D.; Kubelka, D.; Ramac, J. P.; Posedel, D.; Steiner, R.; Vidjak, V.; Brnic, V.; Viskovic, K.; Baraban, V.

    2010-01-01

    Apart from its benefits, the interventional cardiology (IC) is known to generate high radiation doses to patients and medical staff involved. The European Union Medical Exposures Directive 97/43/EURATOM strongly recommend patient dosimetry in interventional radiology, including IC. IC patient radiation doses in four representative IC rooms in Croatia were investigated. Setting reference levels for these procedures have difficulties due to the large difference in procedure complexity. Nevertheless, it is important that some guideline values are available as a benchmark to guide the operators during these potentially high-dose procedures. Local and national diagnostic reference levels (DRLs) were proposed as a guidance. A total of 138 diagnostic (coronary angiography, CA) and 151 therapeutic (PTCA, stenting) procedures were included. Patient irradiation was measured in terms of kerma-area product (KAP), fluoroscopy time (FT) and number of cine-frames (F). KAP was recorded using calibrated KAP-meters. DRLs of KAP, FT and F were calculated as third quartile values rounded up to the integer. Skin doses were assessed on a selected sample of high skin dose procedures, using radiochromic films, and peak skin doses (PSD) were presented. A relative large range of doses in IC was detected. National DRLs were proposed as follows: 32 Gy cm 2 , 6.6 min and 610 frames for CA and 72 Gy cm 2 , 19 min and 1270 frames for PTCA. PSD 2 Gy in 8% of selected patients. Measuring the patient doses in radiological procedures is required by law, but rarely implemented in Croatia. The doses recorded in the study are acceptable when compared with the literature, but optimisation is possible. The preliminary DRL values proposed may be used as a guideline for local departments, and should be a basis for radiation reduction measures and quality assurance programmes in IC in Croatia. (authors)

  10. Dose distribution in lungs and thyroid from scatter photons of x-ray mammography imaging

    International Nuclear Information System (INIS)

    Faghihi, R.; Mehdizadeh, S.

    2006-01-01

    The contribution of scatter photons in dose of mammography image in thyroid and lungs are studied. Thyroid and in the form of distribution function and total delivered dose studied by direct measurement with Thermoluminescence dosimeter. The results of measurements compared to other published measurements and the total dose compared to our modelling with Monte Carlo method.. Our phantoms for direct measurement of Dose are a compressed breast phantom placed on a female RANDO phantom. The results of modelling and measurement are in agreement for the total delivered dose to thyroid and lungs and comparable to doses reported by the other researcher

  11. Muscle-invasive bladder cancer treated with external beam radiation: influence of total dose, overall treatment time, and treatment interruption on local control

    International Nuclear Information System (INIS)

    Moonen, L.; Voet, H. van der; Nijs, R. de; Horenblas, S.; Hart, A.A.M.; Bartelink, H.

    1998-01-01

    Purpose: To evaluate and eventually quantify a possible influence of tumor proliferation during the external radiation course on local control in muscle invasive bladder cancer. Methods and Materials: The influence of total dose, overall treatment time, and treatment interruption has retrospectively been analyzed in a series of 379 patients with nonmetastasized, muscle-invasive transitional cell carcinoma of the urinary bladder. All patients received external beam radiotherapy at the Netherlands Cancer Institute between 1977 and 1990. Total dose varied between 50 and 75 Gy with a mean of 60.5 Gy and a median of 60.4 Gy. Overall treatment time varied between 20 and 270 days with a mean of 49 days and a median of 41 days. Number of fractions varied between 17 and 36 with a mean of 27 and a median of 26. Two hundred and forty-four patients had a continuous radiation course, whereas 135 had an intended split course or an unintended treatment interruption. Median follow-up was 22 months for all patients and 82 months for the 30 patients still alive at last follow-up. A stepwise procedure using proportional hazard regression has been used to identify prognostic treatment factors with respect to local recurrence as sole first recurrence. Results: One hundred and thirty-six patients experienced a local recurrence and 120 of these occurred before regional or distant metastases. The actuarial local control rate was 40.3% at 5 years and 32.3% at 10 years. In a multivariate analysis total dose showed a significant association with local control (p 0.0039), however in a markedly nonlinear way. In fact only those patients treated with a dose below 57.5 Gy had a significant higher bladder relapse rate, whereas no difference in relapse rate was found among patients treated with doses above 57.5 Gy. This remained the case even after adjustment for overall treatment time and all significant tumor and patient characteristics. The Normalized Tumor Dose (NTD) (α/β = 10) and NTD (

  12. A reviewed technique for total body electron therapy using a Varian Clinac 2100C/D high dose rate treatment beam facility

    International Nuclear Information System (INIS)

    Oliver, L.D.; Xuereb, E.M.A.; Last, V.; Hunt, P.B.; Wilfert, A.

    1996-01-01

    Our (Royal North Shore Hospital) most recent linear accelerator acquisition is a Varian Clinac 2100C/D which has a high dose rate (approximately 25Gy per minute at 1 metre) total body electron option. We investigated the physical characteristics of the electron beam to develop a suitable method of treatment for total body electron therapy. The useful electron beam width is defined as 80cm above and below the reference height. Measurements of the electron dose received from the two angled electron beams showed a critical dependence on the gantry angles. The treatment protocol uses ten different patient angles, fractionated into directly opposing fields and treated seuqentially each day. A full cycle of treatment is completed in five days. (author)

  13. Predicting thyroxine requirements following total thyroidectomy.

    Science.gov (United States)

    Mistry, Dipan; Atkin, Stephen; Atkinson, Helen; Gunasekaran, Sinnappa; Sylvester, Deborah; Rigby, Alan S; England, R James

    2011-03-01

    Optimal thyroxine replacement following total thyroidectomy is critical to avoid symptoms of hypothyroidism. The aim of this study was to determine the best formula to determine the initiated replacement dose of levothyroxine immediately following total thyroidectomy. Prospective study. All patients were initiated on 100 μg levothyroxine and titrated to within the reference range for TSH and free T4. Correlations to height, weight, age, lean body mass (LBM), body surface area (BSA) and body mass index (BMI) were calculated. One hundred consecutive adult patients underwent total thyroidectomy for non-malignant disease. Comparison between three methods of levothyroxine dose prediction, aiming for a levothyroxine dose correct to within 25 μg of actual dose required. Correlations were seen between levothyroxine dose and patient age (r=-0.346, Pregression equation was calculated (predicted levothyroxine dose=[0·943 × bodyweight] + [-1.165 × age] + 125.8), simplified to (levothyroxine dose= bodyweight - age + 125) pragmatically. Initiating patients empirically on 100 μg post-operatively showed that 40% of patients achieved target within 25 μg of their required dose; this increased to 59% when using a weight-only dose calculation (1.6 μg/kg) and to 72% using the simplified regression equation. A simple calculated regression equation gives a more accurate prediction of initiated levothyroxine dose following total thyroidectomy, reducing the need for outpatient attendance for dose titration. © 2011 Blackwell Publishing Ltd.

  14. Chronic total coronary occlusion: treatment results.

    Science.gov (United States)

    Kirk Christensen, Martin; Freeman, Phillip Fischer; Rasmussen, Jeppe Groendal; Villadsen, Anton Boel; Raungaard, Bent; Eggert Jensen, Svend; Thuesen, Leif

    2017-08-01

    To describe the clinical and procedural coronary chronic total occlusion (CTO) treatment results in a Nordic PCI centre during the implementation of a CTO treatment program. In a retrospective registry study, we assessed; (1) indication for the procedure, (2) Canadian Cardiovascular Society angina pectoris score (CCS)/New York Heart Association (NYHA) heart failure score, (3) lesion complexity and (4) adverse events during hospital stay and three months following the index procedure. The study cohort included 503 patients (594 lesions). From 2010 to 2013 96% of procedures were performed with antegrade wire-escalation technique and 4% performed using retrograde techniques, from 2013-2016 the corresponding numbers were 83% and 17.0%. The procedural success rate was 69%, increasing from 64% before to 72% (p = .06) after routinely using the retrograde approach. No individual patient characteristic, lesion variable or score was strongly associated with procedural success or failure. There were 4% serious procedure related complications. In patients with PCI of a CTO lesion only, 87% were in CCS or NYHA functional class ≥2 before the index procedure vs. 22% at follow-up. Routine use of retrograde techniques tended to increase the procedural success rate. Clinical results after three months were acceptable, but the complication rate was higher than for non-CTO PCI. Individual patient and lesion characteristics had a low predictability for procedural success. Therefore, clinical symptoms, objective signs of myocardial ischemia and procedural risk should be focus points in coronary chronic total occlusion treatment strategies.

  15. Collagen synthesis in CBA mouse heart after total thoracic irradiation

    International Nuclear Information System (INIS)

    Murray, J.C.; Parkins, C.S.; Institute of Cancer Research, Sutton

    1988-01-01

    CBA mice were irradiated to the whole thorax with single doses of 240 kVp X-rays in the dose range 8-16 Gy. Collagen and total protein synthesis rates in the heart were measured at 2-monthly intervals using a radio-isotope incorporation techniques. Doses of 10 Gy or greater caused a slight increase in collagen synthesis, followed by significantly reduced collagen synthesis by 16 weeks or longer after treatment. The depression in synthesis appeared correspondingly earlier with increasing dose. Total protein synthesis in heart followed similar patterns although changes were not statistically significant, indicating that the changes reflected alterations to collagen synthesis specifally, and not protein synthesis in geneal. Total hydroxyproline measurements showed no significant changes in heart collagen at any time as a result of X-irradiation. 18 refs.; 7 figs

  16. A combination of high dose rate (10X FFF/2400 MU/min/10 MV X-rays) and total low dose (0.5 Gy) induces a higher rate of apoptosis in melanoma cells in vitro and superior preservation of normal melanocytes.

    Science.gov (United States)

    Sarojini, Sreeja; Pecora, Andrew; Milinovikj, Natasha; Barbiere, Joseph; Gupta, Saakshi; Hussain, Zeenathual M; Tuna, Mehmet; Jiang, Jennifer; Adrianzen, Laura; Jun, Jaewook; Catello, Laurice; Sanchez, Diana; Agarwal, Neha; Jeong, Stephanie; Jin, Youngjin; Remache, Yvonne; Goy, Andre; Ndlovu, Alois; Ingenito, Anthony; Suh, K Stephen

    2015-10-01

    The aim of this study was to determine the apoptotic effects, toxicity, and radiosensitization of total low dose irradiation delivered at a high dose rate in vitro to melanoma cells, normal human epidermal melanocytes (HEM), or normal human dermal fibroblasts (HDF) and to study the effect of mitochondrial inhibition in combination with radiation to enhance apoptosis in melanoma cells. Cells irradiated using 10X flattening filter-free (FFF) 10 MV X-rays at a dose rate of 400 or 2400 MU/min and a total dose of 0.25-8 Gy were analyzed by cell/colony counting, MitoTracker, MTT, and DNA-damage assays, as well as by quantitative real-time reverse transcriptase PCR in the presence or absence of mitochondrial respiration inhibitors. A dose rate of 2400 MU/min killed on average five-fold more melanoma cells than a dose rate 400 MU/min at a total dose of 0.5 Gy and preserved 80% survival of HEM and 90% survival of HDF. Increased apoptosis at the 2400 MU/min dose rate is mediated by greater DNA damage, reduced cell proliferation, upregulation of apoptotic genes, and downregulation of cell cycle genes. HEM and HDF were relatively unharmed at 2400 MU/min. Radiation induced upregulation of mitochondrial respiration in both normal and cancer cells, and blocking the respiration with inhibitors enhanced apoptosis only in melanoma cells. A high dose rate with a low total dose (2400 MU/min, 0.5 Gy/10X FFF 10 MV X-rays) enhances radiosensitivity of melanoma cells while reducing radiotoxicity toward HEM and HDF. Selective cytotoxicity of melanoma cells is increased by blocking mitochondrial respiration.

  17. The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restriction and total sleep deprivation

    Science.gov (United States)

    Van Dongen, Hans P A.; Maislin, Greg; Mullington, Janet M.; Dinges, David F.

    2003-01-01

    OBJECTIVES: To inform the debate over whether human sleep can be chronically reduced without consequences, we conducted a dose-response chronic sleep restriction experiment in which waking neurobehavioral and sleep physiological functions were monitored and compared to those for total sleep deprivation. DESIGN: The chronic sleep restriction experiment involved randomization to one of three sleep doses (4 h, 6 h, or 8 h time in bed per night), which were maintained for 14 consecutive days. The total sleep deprivation experiment involved 3 nights without sleep (0 h time in bed). Each study also involved 3 baseline (pre-deprivation) days and 3 recovery days. SETTING: Both experiments were conducted under standardized laboratory conditions with continuous behavioral, physiological and medical monitoring. PARTICIPANTS: A total of n = 48 healthy adults (ages 21-38) participated in the experiments. INTERVENTIONS: Noctumal sleep periods were restricted to 8 h, 6 h or 4 h per day for 14 days, or to 0 h for 3 days. All other sleep was prohibited. RESULTS: Chronic restriction of sleep periods to 4 h or 6 h per night over 14 consecutive days resulted in significant cumulative, dose-dependent deficits in cognitive performance on all tasks. Subjective sleepiness ratings showed an acute response to sleep restriction but only small further increases on subsequent days, and did not significantly differentiate the 6 h and 4 h conditions. Polysomnographic variables and delta power in the non-REM sleep EEG-a putative marker of sleep homeostasis--displayed an acute response to sleep restriction with negligible further changes across the 14 restricted nights. Comparison of chronic sleep restriction to total sleep deprivation showed that the latter resulted in disproportionately large waking neurobehavioral and sleep delta power responses relative to how much sleep was lost. A statistical model revealed that, regardless of the mode of sleep deprivation, lapses in behavioral alertness

  18. Radiological dose reconstruction for birds reconciles outcomes of Fukushima with knowledge of dose-effect relationships

    International Nuclear Information System (INIS)

    Garnier-Laplace, Jacqueline; Beaugelin-Seiller, Karine; Della-Vedova, Claire; Metivier, Jean-Michel; Ritz, Christian; Mousseau, Timothy A.; Pape Moeller, Anders

    2015-01-01

    We reconstructed the radiological dose for birds observed at 300 census sites in the 50-km northwest area affected by the accident at the Fukushima Daiichi nuclear power plant over 2011-2014. Substituting the ambient dose rate measured at the census points (from 0.16 to 31 μGy h -1 ) with the dose rate reconstructed for adult birds of each species (from 0.3 to 97 μGy h -1 ), we confirmed that the overall bird abundance at Fukushima decreased with increasing total doses. This relationship was directly consistent with exposure levels found in the literature to induce physiological disturbances in birds. Among the 57 species constituting the observed bird community, we found that 90% were likely chronically exposed at a dose rate that could potentially affect their reproductive success. We quantified a loss of 22.6% of the total number of individuals per increment of one unit log10-transformed total dose (in Gy), over the four-year post-accident period in the explored area. We estimated that a total dose of 0.55 Gy reduced by 50% the total number of birds in the study area over 2011-2014. The data also suggest a significant positive relationship between total dose and species diversity. (authors)

  19. Correlation of patient maximum skin doses in cardiac procedures with various dose indicators

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.; Werduch, A.; Religa, W.

    2008-01-01

    In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose-area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7-27.3) min, (16-317) Gy cm 2 and (43-1507) mGy, respectively, and for interventions, accordingly (2.1-43.6) min, (17-425) Gy cm 2 , (71-1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295-4689) mGy and (121-1768) mGy and for PCI (267-6524) mGy and (68-2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities. (authors)

  20. Estimation of the genetically significant dose resulting from diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1978-01-01

    Based on the average gonad dose received per examination or per film and on the frequency of x-ray examinations (36 million per annum), the mean annual gonad dose to individuals in the GDR has been determined to be 33 mR. Considering different age groups of patients and the fact that the gonad dose to children is often significantly reduced in comparison to adults, estimates of the genetically significant dose (GSD) range from 7 to 19 mR per annum. Examinations of women have accounted for about 66 per cent of the GSD. The highest contribution to the GSD result from examinations of the following organs: kidneys, colon, bile duct (only in women), lumbar spine, pelois, hips, and proximal femur. Despite their high frequency, examinations of the stomach account for only about 3 per cent of the GSD. All thorax examinations (nearly 10,000,000 per annum) contribute less than 0.5 per cent, and the most frequent x-ray examinations of the skeletal system, skull, cervical spine, and teeth account for less than 3 per cent. The GSD values obtained are comparable with those from countries such as India, Japan, Netherlands, USSR, and USA. (author)

  1. Low-dose 4D cone-beam CT via joint spatiotemporal regularization of tensor framelet and nonlocal total variation

    Science.gov (United States)

    Han, Hao; Gao, Hao; Xing, Lei

    2017-08-01

    Excessive radiation exposure is still a major concern in 4D cone-beam computed tomography (4D-CBCT) due to its prolonged scanning duration. Radiation dose can be effectively reduced by either under-sampling the x-ray projections or reducing the x-ray flux. However, 4D-CBCT reconstruction under such low-dose protocols is prone to image artifacts and noise. In this work, we propose a novel joint regularization-based iterative reconstruction method for low-dose 4D-CBCT. To tackle the under-sampling problem, we employ spatiotemporal tensor framelet (STF) regularization to take advantage of the spatiotemporal coherence of the patient anatomy in 4D images. To simultaneously suppress the image noise caused by photon starvation, we also incorporate spatiotemporal nonlocal total variation (SNTV) regularization to make use of the nonlocal self-recursiveness of anatomical structures in the spatial and temporal domains. Under the joint STF-SNTV regularization, the proposed iterative reconstruction approach is evaluated first using two digital phantoms and then using physical experiment data in the low-dose context of both under-sampled and noisy projections. Compared with existing approaches via either STF or SNTV regularization alone, the presented hybrid approach achieves improved image quality, and is particularly effective for the reconstruction of low-dose 4D-CBCT data that are not only sparse but noisy.

  2. Results of the Phase I Dose-Escalating Study of Motexafin Gadolinium With Standard Radiotherapy in Patients With Glioblastoma Multiforme

    International Nuclear Information System (INIS)

    Ford, Judith M.; Seiferheld, Wendy; Alger, Jeffrey R.; Wu, Genevieve; Endicott, Thyra J.; Mehta, Minesh; Curran, Walter; Phan, See-Chun

    2007-01-01

    Purpose: Motexafin gadolinium (MGd) is a putative radiation enhancer initially evaluated in patients with brain metastases. This Phase I trial studied the safety and tolerability of a 2-6-week course (10-22 doses) of MGd with radiotherapy for glioblastoma multiforme. Methods and Materials: A total of 33 glioblastoma multiforme patients received one of seven MGd regimens starting at 10 doses of 4 mg/kg/d MGd and escalating to 22 doses of 5.3 mg/kg/d MGd (5 or 10 daily doses then three times per week). The National Cancer Institute Cancer Therapy Evaluation Program toxicity and stopping rules were applied. Results: The maximal tolerated dose was 5.0 mg/kg/d MGd (5 d/wk for 2 weeks, then three times per week) for 22 doses. The dose-limiting toxicity was reversible transaminase elevation. Adverse reactions included rash/pruritus (45%), chills/fever (30%), and self-limiting vesiculobullous rash of the thumb and fingers (42%). The median survival of 17.6 months prompted a case-matched analysis. In the case-matched analysis, the MGd patients had a median survival of 16.1 months (n = 31) compared with the matched Radiation Therapy Oncology Group database patients with a median survival of 11.8 months (hazard ratio, 0.43; 95% confidence interval, 0.20-0.94). Conclusion: The maximal tolerated dose of MGd with radiotherapy for glioblastoma multiforme in this study was 5 mg/kg/d for 22 doses (daily for 2 weeks, then three times weekly). The baseline survival calculations suggest progression to Phase II trials is appropriate, with the addition of MGd to radiotherapy with concurrent and adjuvant temozolomide

  3. Doses of irradiation to the Ukrainian population as a result of the Chernobyl accident

    International Nuclear Information System (INIS)

    Lichtarjov, I.A.; Kovgan, L.N.

    1991-01-01

    In the middle of 1990 the whole problem of the assessment of exposure doses to the population living near the Chernobyl plant can be divided into several separate problems: - storage, handling, organization and primary analysis of direct measurement results of external and internal doses to the people; - usage of the available information for the models of retrospective reconstruction of the past exposure doses and for prediction of possible future doses; - verification and validation of mentioned models by means of constant comparison of calculation results received on their basis to the results of current instrumental monitoring. Three problems mentioned above are solving in the laboratory of mathematical models and radiation prediction in dosimetry and radiation hygiene department of AUSCRM USSR AMS. The given report presents the description of the first results of this work. (author)

  4. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  5. Total dose radiation effects of pressure sensors fabricated on uni-bond-SOI materials

    International Nuclear Information System (INIS)

    Zhu Shiyang; Huang Yiping; Wang Jin; Li Anzhen; Shen Shaoqun; Bao Minhang

    2001-01-01

    Piezoresistive pressure sensors with a twin-island structure were successfully fabricated using high quality Uni-bond-SOI (On Insulator) materials. Since the piezoresistors were structured by the single crystalline silicon overlayer of the SOI wafer and were totally isolated by the buried SiO 2 , the sensors are radiation-hard. The sensitivity and the linearity of the pressure sensors keep their original values after being irradiated by 60 Co γ-rays up to 2.3 x 10 4 Gy(H 2 O). However, the offset voltage of the sensor has a slight drift, increasing with the radiation dose. The absolute value of the offset voltage deviation depends on the pressure sensor itself. For comparison, corresponding polysilicon pressure sensors were fabricated using the similar process and irradiated at the same condition

  6. Dose escalation without split-course chemoradiation for anal cancer: results of a phase II RTOG study

    International Nuclear Information System (INIS)

    John, Madhu; Pajak, Thomas; Kreig, Richard; Pinover, Wayne H.; Myerson, Robert

    1997-01-01

    PURPOSE: An attempt at radiotherapy (RT) dose escalation (from 45 Gy to 59.6 Gy) in a Radiation Therapy Oncology Group (RTOG) chemoradiation protocol for advanced anal cancers had resulted in an unexpectedly high 1-year colostomy rate (23%) and local failure (The Cancer Journal from Scientific American 2 (4):205-211, 1996). This was felt to be probably secondary to the split course chemoradiation (CR) that was mandated in the protocol. A second phase of this dose escalation study was therefore undertaken without a mandatory split and with an identical RT dose (59.6 Gy) and chemotherapy. MATERIALS AND METHODS: Twenty patients with anal cancers ≥2 cms were treated with a concurrent combination of 59.6 Gy to the pelvis and perineum (1.8 Gy daily, 5 times per week in 33 fractions over 6 (1(2)) weeks) and two cycles of 5 fluorouracil infusion (1000 mg/m 2 over 24 hours for 4 days) and mitomycin C (10 mg/m 2 bolus). A 10 day rest period was allowed only for severe skin reactions. A comparative analysis was made with the 47 patients in the earlier phase of this study who were treated with the identical chemoradiation course but with a mandatory 2-week break at the 36.00 Gy level. RESULTS: Predominant Grade 3 and 4 toxicities in 18 evaluable patients with dermatitis ((14(18)) or 78%), hematologic ((14(18)) or 78%), infection ((3(18)) or 17%) and gastrointestinal ((5(18)) or 28%). There were no fatalities. Nine patients (50%) completed the planned course without a break; 9 others (50%) had their treatments interrupted for a median of 11 days (range 7-19 days) at a median dose of 41.4 Gy (range 32.4 to 48.6 Gy). This compared to (40(47)) patients (85%) who had a 12 day treatment interruption at 36 Gy total dose in a planned break group. One patient had an abdomino-perineal resection (APR) for persistent disease and another for an anal fissure for (2(18)) or 11% 1-year colostomy rate. This was again favorably comparable to 23% 1-year colostomy rate for the earlier group of

  7. Comparison of high dose rate (HDR) and low dose rate (LDR) brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone. The preliminary results

    International Nuclear Information System (INIS)

    Trippe, Nivaldo; Novaes, P.E.; Ferrigno, R.; Pellizzon, A.C.; Salvajoli, J.V.; Fogaroli, R.C.; Maia, M.A.C.; Baraldi, H.E.

    1996-01-01

    Purpose/Objective: To compare the results between HDR and LDR brachytherapy in the treatment of stage IIIB cervix cancer with radiation therapy alone through a prospective and randomized trial. Materials and Methods: From September 1992 to December 1993, 65 patients with stage IIIB cervical cancer were randomized to one of the following treatment schedule according to the brachytherapy used to complement the dose of external beam radiotherapy (EBRT): 1 - High dose rate (HDR) - 36 patients - 4 weekly insertions of 6,0 Gy at point A 2 - Low dose rate (LDR) - 29 patients - 2 insertions two weeks apart of 17,5 Gy at point A The External Beam radiotherapy was performed through a Linac 4MV, in box arrangement for whole pelvis and in AP-PA fields for parametrial complementation of dose. The dose at the whole pelvis was 45 Gy in 25 fractions of 1,8 Gy and the parametrial dose was 16 Gy. The brachytherapy was realized with Fletcher colpostats and intrauterine tandem, in both arms. The HDR brachytherapy was realized through a Micro-Selectron device, working with Iridium-192 with initial activity of 10 Ci and started ten days after the beginning of EBRT. The total treatment time was shortened in two weeks for this group. The LDR brachytherapy started only after the end of EBRT. Results: With the minimum follow up of 24 months and medium of 31 months, the disease free survival was 50% among the 36 patients in HDR group and 47,8% among the 29 patients in LDR group. Local failures occurred in 50% and 52,8% respectively. Grade I and II complications were restricted to rectites and cistites and the incidence of them was 8,3% for HDR group and 13% for LDR group. Until the time of evaluation there were no grade III complications in any group. Conclusions: Although the number of patients is small and the time of follow up still short, these preliminary results suggest that the HDR brachytherapy has an equivalent efficiency in local control as the LDR in the treatment of stage IIIB

  8. Financial, operating results, assets total down for OGJ300

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Financial and operating results of the Oil and Gas Journal 300 dropped again in 1992. It was the second consecutive set of declines for OGJ's list of the largest publicly traded, oil and gas producing companies in the U.S. Totals fell from 1991 results in almost all categories for financial and operating performance. Group net income fell sharply in 1992. Large, integrated companies reported sharp earnings declines, many of them related to special charges for restructuring and mandatory accounting changes. In addition, revenues were suppressed by lower crude and product prices below levels of 1991 and a decline in total crude production. This was partially offset by higher prices and demand for natural gas and by increased demand for petroleum products. The paper discusses the economic situation in the petroleum and natural gas industries then gives extensive data on the following: total assets, total income, net income, stockholders' equity, capital spending, worldwide and US liquids production, worldwide and US natural gas production, worldwide and US liquids reserves, worldwide and US natural gas reserves, and US net wells drilled

  9. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  10. Study of hard X-ray dose enhancement effects for some kinds of semiconductor devices

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Zhou Hui; He Chao Hui; Xie Ya Ning; Huang Yu Ying; He Wei; Hu Tian Dou

    2002-01-01

    Experimental results of X-ray dose enhancement effects are given for CMOS4069 and floating gate ROMs irradiated in Beijing Synchrotron Radiation Facility and in cobalt source. Shift of threshold voltage vs. total dose for CMOS4069 and the errors vs. total dose for 28f256 and 29c256 have been tested on line and the equivalent relation of total dose damage under the same accumulated dose is provided comparing the response of devices irradiated by X-ray and gamma-ray source. These results can be provided for X-ray radiation hardening technology as an effective evaluation data

  11. Effects of total dose of ionizing radiation on integrated circuits

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Marcilei A.G.; Cirne, K.H.; Gimenez, S.; Santos, R.B.B. [Centro Universitario da FEI, Sao Bernardo do Campo, SP (Brazil); Added, N.; Barbosa, M.D.L.; Medina, N.H.; Tabacniks, M.H. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica; Lima, J.A. de; Seixas Junior, L.E.; Melo, W. [Centro de Tecnologia da Informacao Paulo Archer, Sao Paulo, SP (Brazil)

    2011-07-01

    Full text: The study of ionizing radiation effects on materials used in electronic devices is of great relevance for the progress of global technological development and, particularly, it is a necessity in some strategic areas in Brazil. Electronic circuits are strongly influenced by radiation and the need for IC's featuring radiation hardness is largely growing to meet the stringent environment in space electronics. On the other hand, aerospace agencies are encouraging both scientific community and semiconductors industry to develop hardened-by-design components using standard manufacturing processes to achieve maximum performance, while significantly reducing costs. To understand the physical phenomena responsible for changes in devices exposed to ionizing radiation several kinds of radiation should then be considered, among them alpha particles, protons, gamma and X-rays. Radiation effects on the integrated circuits are usually divided into two categories: total ionizing dose (TID), a cumulative dose that shifts the threshold voltage and increases transistor's off-state current; single events effects (SEE), a transient effect which can deposit charge directly into the device and disturb the properties of electronic circuits. TID is one of the most common effects and may generate degradation in some parameters of the CMOS electronic devices, such as the threshold voltage oscillation, increase of the sub-threshold slope and increase of the off-state current. The effects of ionizing radiation are the creation of electron-hole pairs in the oxide layer changing operation mode parameters of the electronic device. Indirectly, there will be also changes in the device due to the formation of secondary electrons from the interaction of electromagnetic radiation with the material, since the charge carriers can be trapped both in the oxide layer and in the interface with the oxide. In this work we have investigated the behavior of MOSFET devices fabricated with

  12. Effects on Ferroelectric Thin-Film Stacks and Devices for Piezoelectric MEMS Applications at Varied Total Ionizing Dose (TID)

    Science.gov (United States)

    2017-03-01

    non -linearly mobile internal interfaces, e.g. domain walls and eventual phase boundaries. Radiation exposure is expected...zirconate titanate; PZT; actuator; radiation ; gamma; total ionization dose; TID; top electrode; Pt; IrO2; polarization; PE; hysteresis; permittivity...Hayashigawa, et. al., “A 2 Mbit Radiation Hardened Stackable Ferroelectric Memory” Non - Volatile Memory Technology Symposium, NVMTS 07, Nov 10-13, 2007 Albuquerque, NM, USA

  13. Effect of high-dose preoperative methylprednisolone on recovery after total hip arthroplasty

    DEFF Research Database (Denmark)

    Lunn, T H; Andersen, Lasse Østergaard; Kristensen, B B

    2013-01-01

    (IQR) (95% CI), MP vs placebo]: 23.5 (23.3-23.7) (17.8-43.8) vs 23.5 (23.0-23.8) (20.0-46.8) h, the mean difference (95% CI) being -1.3 (-4.7 to 2.2) h, P=0.65. Overall pain for the first 24 h after surgery was significantly reduced in the MP vs the placebo group (PMP 125 mg i.v. before surgery added......BACKGROUND: /st>High-dose glucocorticoid may reduce postsurgical pain and improve recovery. We hypothesized that 125 mg methylprednisolone (MP) would reduce time to meet functional discharge criteria after total hip arthroplasty (THA). METHODS: /st>Forty-eight patients undergoing unilateral THA...... under spinal anaesthesia were consecutively included in this randomized, double-blind, placebo-controlled trial receiving preoperative i.v. MP or saline. All patients received a standardized, multimodal analgesic regime with paracetamol, celecoxib, and gabapentin. The primary outcome was time to meet...

  14. Estimation of population doses from chest mass screening, 1975

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Maruyama, Takashi

    1977-01-01

    The population doses in mass photofluorography of the chest were estimated on the basis of nation-wide radiological survey. A total frequency of photofluorographic examinations for the chest mass survey was 18.3 million for males and 15.0 million for females, with a total of 33.3 million. Mass surveys of the chest during the school age are carried out only at the time of admission into the primary school (5 or 6 years old) and at the second class of the junior high school (13 or 14 years old). The gonad doses were determined with an ionization chamber placed at the position of gonad in tissue-equivalent phantoms. The active bone marrow was subdivided into 72 elements. The dose contribution to the marrow arising from the particular exposure conditions was calculated at each site within the elements, using the depth-dose curves experimentally determined and the proportion of the total active bone marrow present at that site. The resultant genetically significant dose for males and females was 0.07 and 0.025 mrad per person per year, respectively, with a total of 0.032 mrad per person per year. The per Caput mean marrow dose for male and female was 5.5 and 4.2 mrad per year, respectively, with a total of 9.7 mrad per year. The leukemia significant dose was calculated from the per Caput mean marrow dose by adopting weighting factor, that is leukemia significant factor. The resultant leukemia significant factor for male and female was 5.2 and 4.1 mrad per person per year, respectively. (auth.)

  15. Thyroid doses in Belarus resulting from the Chernobyl accident: comparison of the estimates based on direct thyroid measurements and on measurements of 131I in milk

    International Nuclear Information System (INIS)

    Shinkarev, Sergey; Gavrilin, Yury; Khrouch, Valery; Savkin, Mikhail; Bouville, Andre; Luckyanov, Nicholas

    2008-01-01

    A substantial increase of childhood cancer cases observed in Belarus, Ukraine and Russia after the Chernobyl accident has been associated with thyroid exposure to radio iodines following the accident. A large number of direct thyroid measurements (i.e. measurement of the exposure rate near the thyroid of the subject)were conducted in Belarus during a few weeks after the accident. Individual thyroid doses based on results of the direct thyroid measurements were estimated for about 126,000 Belarusian residents and settlement-average thyroid doses for adults were calculated for 426 contaminated settlements in Gomel and Mogilev Oblasts. Another set of settlement-average thyroid doses for adults was estimated based on results of activity measurements in milk samples for 28 settlements (with not less than 2 spectrometric measurements) and 155 settlements (with not less than 5 total beta-activity measurements) in Gomel and Mogilev Oblasts. Concentrations of 131 I in milk were derived from these measurements. In the estimation of this set of thyroid doses, it was assumed that adults consumed 0.5 L d -1 of milk locally produced. The two sets of dose estimates were compared for 47 settlements, for which simultaneously were available a dose estimate based on thyroid measurements and a dose estimate based either on spectrometric or radiometric milk data. The settlement average thyroid doses based on milk activity measurements were higher than those based on direct thyroid measurements by a factor of 1.8 for total beta-activity measurements (30 settlements were compared) and by a factor of 2.4 for spectrometric measurements (17 settlements). This systematic difference can be explained by overestimation of the milk consumption rate used in the calculation of the milk-based thyroid doses and/or by application of individual countermeasures by people. (author)

  16. The effects of dose rate in total body irradiation of dogs

    International Nuclear Information System (INIS)

    Kolb, H.J.; Bodenberger, U.; Holler, E.; Thierfelder, S.; Eckstein, R.

    1986-01-01

    In summary the studies in dogs show that the dose rate or exposure time has a great impact on survival of acute radiation syndromes. In contrast the inactivation of colony forming hemopoietic precursors is less influenced by the dose rate. The potential of hemopoietic recovery is determined by the survival of hemopoietic precursor cells. Therefore in patients with a suspected whole body exposure of more than 1.50 Gy, bacterial and fungal decontamination and reverse isolation in a sterile environment has to be started immediately. Human patients treated with about 10 Gy of TBI frequently developed nausea, elevated temperatures and swelling of the parotic glands at the first and second day. The extent of these changes varies from patient to patient. The temperature is rarely elevated above 38.5 0 C. The swelling of parotics and the nausea subside within 48 hours. The presence of such systemic symptoms may suggest the exposure to a lethal dose of radiation. The disappearance of immature red cells, i.e. reticulocytes, and bandforms of granulocytes within the first 5 days supports this suggestion. HLA typing of the victim and his family should be performed as soon as possible after the accident. An HLA-identical sibling would be a suitable bone marrow donor. Unlike therapeutic TBI accidental exposures bring about uncertainties in the calculation of dose, dose distribution and dose rate. Early after irradiation biological changes are extremely variable. Both biological and physical data have to be considered, when microbiological decontamination, reverse isolation and transplantation of bone marrow are to be decided upon. Obviously these intensive therapeutic efforts are limited to a small number of victims. (orig.)

  17. Determination of the maximum individual dose exposure resulting from a hypothetical LEU plate-melt accident

    International Nuclear Information System (INIS)

    Abdelhady, Amr

    2013-01-01

    Highlights: ► Studying the radioactive release results from hypothetical plate-melt accident. ► Hotspot code was used to study the dose distributions around the reactor. ► A 90% decrease in the received dose in proper operation of filtration. ► The received dose is lower than the annual permissible dose after filtration. - Abstract: The objective of this study was to provide an estimate of the potential impact of accidental radioactive release from the testing cell of the Egyptian second research reactor ETRR-2 on the dose level of public around the reactor. The assessment was performed for two cases: an evaluation of the impact that accidental release has on the dose that would be received by public around the reactor in case of proper operation of testing cell filtration system; and an assessment of the potential dose in case of loss of testing cell filtration system. The results show that the filtration system has a great role in decreasing the dose received by an individual located outside the reactor to a dose level lower than the annual permissible dose

  18. Fetal dose evaluation during breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Antypas, Christos; Sandilos, Panagiotis; Kouvaris, John; Balafouta, Ersi; Karinou, Eleftheria; Kollaros, Nikos; Vlahos, Lambros

    1998-01-01

    Purpose: The aim of the work was to estimate the radiation dose delivered to the fetus in a pregnant patient irradiated for breast cancer. Methods and Materials: A 45-year woman was treated for left breast cancer using a 6 MV photon beam with two isocentric opposing tangential unwedged fields. Daily dose was 2.3 Gy at 95% isodose line given by two fields/day, 5 days/week. A total dose of 46 Gy was given in 20 fractions over a 4-week period. Pregnancy confirmed during the second therapeutic week. Treatment lasted between the second and sixth gestation week. Radiation dose to fetus was estimated from in vivo and phantom measurements using thermoluminescence dosimeters and an ionization chamber. In vivo measurements were performed by inserting either a catheter with TL dosimeters or ionization chamber into the patient's rectum. Phantom measurements were performed by simulating the treatment conditions on an anthropomorphic phantom. Results: TLD measurements (in vivo and phantom) revealed fetal dose to be 0.085% of the tumor dose, corresponding to a cumulative fetal dose of 3.9 cGy for the entire treatment of 46 Gy. Chamber measurements (in vivo and phantom) revealed a fetal dose less than the TLD result: 0.079 and 0.083% of the tumor dose corresponding to cumulative fetal dose of 3.6 cGy and 3.8 cGy for in vivo and phantom measurement, respectively. Conclusions: It was concluded that the cumulative dose delivered to the unshielded fetus was 3.9 cGy for a 46 Gy total tumor dose. The estimated fetal dose is low compared to the total tumor dose given due to the early stage of pregnancy, the large distance between fundus-radiation field, and the fact that no wedges and/or lead blocks were used. No deterministic biological effects of radiation on the live-born embryo are expected. The lifetime risk for radiation-induced fatal cancer is higher than the normal incidence, but is considered as inconsequential

  19. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    International Nuclear Information System (INIS)

    Nalichowski, Adrian; Eagle, Don G.; Burmeister, Jay

    2016-01-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  20. Dosimetric evaluation of total marrow irradiation using 2 different planning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nalichowski, Adrian, E-mail: nalichoa@karmanos.org [Karmanos Cancer Center, Detroit, MI (United States); Eagle, Don G. [Wayne State University School of Medicine, Detroit, MI (United States); Burmeister, Jay [Karmanos Cancer Center, Detroit, MI (United States); Wayne State University School of Medicine, Detroit, MI (United States)

    2016-10-01

    This study compared 2 different treatment planning systems (TPSs) for quality and efficiency of total marrow irradiation (TMI) plans. The TPSs used in this study were VOxel-Less Optimization (VoLO) (Accuray Inc, Sunnyvale, CA) using helical dose delivery on a Tomotherapy Hi-Art treatment unit and Eclipse (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) dose delivery on a Varian iX treatment unit. A total dose of 1200 cGy was prescribed to cover 95% of the planning target volume (PTV). The plans were optimized and calculated based on a single CT data and structure set using the Alderson Rando phantom (The Phantom Laboratory, Salem, NY) and physician contoured target and organ at risk (OAR) volumes. The OARs were lungs, heart, liver, kidneys, brain, and small bowel. The plans were evaluated based on plan quality, time to optimize the plan and calculate the dose, and beam on time. The resulting mean and maximum doses to the PTV were 1268 and 1465 cGy for VoLO and 1284 and 1541 cGy for Eclipse, respectively. For 5 of 6 OAR structures the VoLO system achieved lower mean and D10 doses ranging from 22% to 52% and 3% to 44%, respectively. Total computational time including only optimization and dose calculation were 0.9 hours for VoLO and 3.8 hours for Eclipse. These times do not include user-dependent target delineation and field setup. Both planning systems are capable of creating high-quality plans for total marrow irradiation. The VoLO planning system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing. VoLO's graphics processing unit (GPU)–based optimization and dose calculation algorithm also allowed much faster creation of TMI plans.

  1. Recent results on the linearity of the dose-response relationship for radiation-induced mutations in human cells by low dose levels

    International Nuclear Information System (INIS)

    Traut, H.

    1987-01-01

    Five studies made by various authors in the last years are discussed, which are significant in that the response of human cells to low-dose irradiation is determined directly and not by extrapolation, and which also provide information on the mutagenic effects of low radiation doses. The results of these studies do not indicate any other than a linear response for induction of mutations by low-dose irradiation, nor are there any reasons observable for assuming the existence of a threshold dose. It is very likely therefore that cancer initiation at the low dose level also is characterized by a linear relationship. Although threshold dose levels cannot generally be excluded, and maybe are only too low to be detected by experiment, there is no plausible biophysical argument for assuming the existence of such microdose threshold. (orig./MG) [de

  2. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    Science.gov (United States)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  3. A graphical review of radiogenic animal cancer data using the 'dose and dose-rate map'

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Hoshi, Yuko; Sakai, Kazuo

    2008-01-01

    We have been investigating the effects of low dose or low dose rate irradiation on mice, using our low dose-rate irradiation facilities. In these studies, we found that the effects were highly dependent on both total dose and dose rate. To show this visually, we proposed the 'dose/dose rate map', and plotted the results of our laboratory and our co-workers. The map demonstrated that dose/dose rate plane could be divided into three areas; 1) An area where harmful effects are observed, 2) An area where no harmful effects are observed, and 3) Another area, between previous two areas, where certain protective functions are enhanced. As this map would be a powerful tool to find some trend among the vast numbers of data relating the biological effects of ionizing radiation, we have developed a computer program which plots the collected data on the dose/dose rate map sorting by experimental conditions. In this study, we graphically reviewed and analyzed the data relating to the lifespan studies of animals with a view to determining the relationships between doses and dose rates of ionizing radiation and cancer incidence. The data contains about 800 sets of experiments, which concerns 187,000 animals exposed to gamma ray or X-ray and their 112,000 controls, and total of about 30,000 cancers in exposed animals and 14,000 cancers in controls. About 800 points of data were plotted on the dose/dose rate map. The plot showed that 1) The divided three areas in the dose/dose rate map were generally confirmed by these 800 points of data, and 2) In some particular conditions, e.g. sarcoma by X-rays, the biologically effective area is extended to relatively high dose/dose rate area. (author)

  4. Models for Total-Dose Radiation Effects in Non-Volatile Memory

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Philip Montgomery; Wix, Steven D.

    2017-04-01

    The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models and compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.

  5. Estimation of population doses from diagnostic medical examinations in Japan, 1974. III. Per caput mean marrow dose and leukemia significant dose

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Kumamoto, Y [National Inst. of Radiological Sciences, Chiba (Japan)

    1976-03-01

    The mean per capita marrow dose and leukemia-significant dose from radiographic and fluoroscopic examinations in Japan have been estimated based on a 1974 nation wide survey of randomly sampled hospitals and clinics. To determine the mean marrow dose to an individual from a certain exposure of a given type of examination, the active marrow in the whole body was divided into 119 parts for an adult and 103 for a child. Dosimetric points on which the individual marrow doses were determined were set up in the center of each marrow part. The individual marrow doses at the dosimetric points in the beams of practical diagnostic x-rays were calculated on the basis of the exposure data on the patients selected in the nation wide survey, using depth dose curves experimentally determined for diagnostic x-rays. The mean individual marrow dose was averaged over the active marrow by summing, for each dosimetric point, the product of the fraction of active marrow exposed and the individual marrow dose at the dosimetric point. The leukemia significant dose was calculated by adopting a weighting factor that is, a leukemia significant factor. The factor was determined from the shape of the time-incidence curve for radiation-induced leukemia from the Hiroshima A-bomb and from the survival statistics for the average population. The resultant mean per capita marrow dose from radiographic and fluoroscopic examination was 37.0 and 70.0 mrad/person/year, respectively, with a total of 107.05 mrad/person/year. The leukemia significant dose was 32.1 mrad/person/year for radiographic examination and 61.2 mrad/person/year, with a total of 93.3. These values were compared with those of 1960 and 1969.

  6. Possible changes in the dose of biologically active ultraviolet radiation received by the biosphere in the summertime Arctic due to total ozone interannual variability

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, Aleksandr N. (Institute of Atmospheric Physics, Russian Academy of Sciences, Moscow (Russian Federation))

    1994-12-01

    Data for total ozone measurements since 1972 from the world ozone measuring network have been analyzed to study ozone interannual variability and estimate its possible effect on the UV-B dose received by the arctic biosphere. Possible interannual changes in the UV-B dose received by DNA associated with overall interannual ozone variability, as well as with the quasi-biennial oscillation (QBO) in total ozone were computed for different summer months. In general, the largest interannual variations in UV-B dose may occur in the Russian Arctic, whereas the possible variations in the Canadian Arctic are the smallest. Overall variations in the UV-B dose received by DNA can exceed 25% (2[sigma] criterion) in the Taimyr and Severnaya Zemlya for June and July, and 30% in the Laptev Sea for August. In the European sector of the Arctic, the possible variations are greater than 10%, and can exceed 15% in the north Norwegian Sea for July and 20% in Spitsbergen for August. Possible overall variations in the Canadian Arctic and Alaska are [<=]10%, reaching 15% in Alaska for August, however. The total ozone QBO can also cause essential and (statistically) predicted changes in UV-B radiation. In general, the UV-B dose received by DNA is found to be greater in the Arctic during the westerly phase of the QBO of the equatorial stratospheric wind at 50 mb level than during the easterly phase. The difference can reach or exceed 15% (relative to the mean value) in Taimyr for June and in Severnaya Zemlya for July and August. In northern Europe and Iceland, the difference can reach 10% for August. In the Canadian Arctic, the QBO-related effect is small. In Alaska, the appropriate difference in UV-B dose has an opposite sign for August, exceeding 5% in magnitude

  7. Results of radioiodine therapy of patients with immunogenic and non-immunogenic hyperthyroidism using different radiation doses

    International Nuclear Information System (INIS)

    Moser, E.; Pickardt, C.R.; Mann, K.; Engelhardt, D.; Kirsch, C.M.; Knesewitsch, P.; Tatsch, K.; Kreisig, T.; Kurz, C.; Saller, B.; Klinikum Grosshadern, Muenchen; Muenchen Univ.

    1988-01-01

    The aim of this study was to check the efficacy of radioiodine ( 131 I) therapy (RIT) in a large number of patients (n = 506) suffering from immunogenic or non-immunogenic hyperthyroidism (Graves' disease, Plummer's disease). Since there is no causal cure for immunogenic hyperthyroidism RIT provides, like all other modalities, only a moderate rate of success which is clearly dose-related. Applying 60 Gy, normal thyroid function can be achieved is only 54% of the cases. A dose of 150 Gy succeeds in 86% of the cases. The solitary decompensated autonomous adenoma (DAA) can be eliminated surgically as well as by RIT with a high degree of success (95%). Contrary to surgery, RIT does not have any noticeable early or late morbidity. The high rate of success of RIT in patients with DAA could be confirmed in two groups with different follow-up periods (16 and 65 months). As expected, the rate of hypothyroidism increased from 11% in the early group to 23% in the late group. Multinodular autonomous adenomas can be eliminated successfully using RIT as well. The concept to apply a dose of 400 Gy to the total functional autonomous tissue as determined by ultrasound yields better results (95%) than 150 Gy to the whole thyroid gland as measured by ultrasound (88%). The rate of hypothyroidism as shown by these results (up to a maximum of 62% after RIT of Graves' disease using 150 Gy) is the lesser evil compared to remaining or recurrent hyperthyroidism since these patients can be treated with thyroid hormones without problems. (orig.) [de

  8. Favorable results after total wrist arthroplasty

    DEFF Research Database (Denmark)

    Boeckstyns, Michel E. H.; Herzberg, G.; Merser, Søren

    2013-01-01

    survival was 0.9 at 5–9 years. Interpretation The clinical results in terms of pain, motion, strength, and function were similar to those in previous reports. The implant survival was 0.9 at 9 years, both in rheumatoid and non-rheumatoid cases, which is an important improvement compared to the earlier......Background and purpose During the past 40 years, several attempts have been made with total wrist arthroplasty to avoid fusion in severely destroyed wrists. The results have often been disappointing. There is only modest clinical documentation due to the small number of patients (especially non......-rheumatoid cases) and short follow-up times. Here we report a multicenter series using a third-generation implant with a minimum follow-up time of 5 years. Methods In 2012, data were retrieved from a registry of consecutive wrist operations at 7 centers with units specialized in hand surgery, between 2003 and 2007...

  9. Experimental study on x-rays dose enhancement effects for floating gate ROMs

    CERN Document Server

    Guo Hong Xia; Chen Yu Sheng; Han Fu Bin; He Chao Hui; Zhao Hui

    2002-01-01

    Experimental results of x-ray dose enhancement effects are given for floating gate read-only memory (ROMs) irradiated in the Beijing Synchrotron Radiation Facility. The wrong byte numbers vs. total irradiation dose have been tested and the equivalent relation of total dose damage is provided compared the response of devices irradiated with sup 6 sup 0 Co gamma-ray source. The x-ray dose enhancement factors for floating gate ROMs are obtained firstly in China. These results can be an effective evaluation data for x-rays radiation hardening technology

  10. Stereotactic ablative radiotherapy for small lung tumors with a moderate dose. Favorable results and low toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Duncker-Rohr, V.; Nestle, U. [Universitaetsklinikum Freiburg (Germany); Momm, F. [Ortenau Klinikum Offenburg (Germany)] [and others

    2013-01-15

    Background: Stereotactic ablative body radiotherapy (SBRT, SABR) is being increasingly applied because of its high local efficacy, e.g., for small lung tumors. However, the optimum dosage is still under discussion. Here, we report data on 45 lung lesions [non-small cell lung cancer (NSCLC) or metastases] in 39 patients treated between 2009 and 2010 by SABR. Patients and methods: SABR was performed with total doses of 35 Gy (5 fractions) or 37.5 Gy (3 fractions) prescribed to the 60% isodose line encompassing the planning target volume. Three-monthly follow-up CT scans were supplemented by FDG-PET/CT if clinically indicated. Results: The median follow-up was 17 months. Local progression-free survival rates were 90.5% (all patients), 95.0% (NSCLC), and 81.8% (metastases) at 1 year. At 2 years, the respective local progression-free survival rates were 80.5%, 95.0%, and 59.7%. Overall survival rates were 71.1% (all patients), 65.4% (NSCLC), and 83.3% (metastases) at 1 year. Overall survival rates at 2 years were 52.7%, 45.9%, and 66.7%, respectively. Acute side effects were mild. Conclusion: With the moderate dose schedule used, well-tolerated SABR led to favorable local tumor control as in other published series. Standardization in reporting the dose prescription for SABR is needed to allow comparison of different series in order to determine optimum dosage. (orig.)

  11. Absorbed body dose simulation in Thyroid cancer therapy using MCNP4Cand ITScodes and comparison to experimental results

    International Nuclear Information System (INIS)

    Hadad, K.; Gorji, Y.

    2004-01-01

    Two standard particle transport codes of MCNP4C and integrated tiger series were used to estimate the total body dose in a thyroid cancer therapy study, with I-131 as the radionuclide source. Human body was modeled by water and soft tissue ellipsoids. Phantoms' dimensions were selected according to Brow nell recommendation. Absorbed fractions were calculated by both codes for different phantoms and for gammas with 0.364 MeV energy, which has the highest fraction in I-131 emitting gammas. Results were compared to the data published by Brow nell et.al.. Figure 1 shows the results of MCNP4C and Integrated Tiger Series with results published by Brow nell et. al.

  12. Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels

    International Nuclear Information System (INIS)

    Antic, V.; Ciraj-Bjelac, O.; Rehani, M.; Aleksandric, S.; Arandjic, D.; Ostojic, M.

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy -1 cm -2 for the first operator, 0.33 mSv Gy -1 cm -2 for the second operator/nurse and 0.16 mSv Gy -1 cm -2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. (authors)

  13. Total dose behavior of partially depleted SOI dynamic threshold voltage MOS (DTMOS) for very low supply voltage applications (0.6 - 1 V)

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Musseau, O.; Leray, J.L.; Faynot, O.; Raynaud, C.; Pelloie, J.L.

    1999-01-01

    In this paper, we presented two DTMOS architectures processed with a partially depleted SOI technology. The first architecture, DTMOS without limiting transistor, is dedicated to ultra-low voltage applications, at 0.6 V. For 1V applications, the second architecture, DTMOS with limiting transistor, needs an additional transistor to limit the body-source diode current. The total dose irradiation of both DTMOS architectures induces no change of the drain current, but an increase of the body-source diode current. Total dose induced trapped charge in the buried oxide increases the body potential of the DTMOS transistor. It induces an increase of the current flow at the back interface of the silicon film. Irradiation of complex circuits using DTMOS transistors would lead to a degradation of the stand-by consumption. (authors)

  14. Increased mortality by septicemia, interstitial pneumonitis and pulmonary fibrosis among bone marrow transplant recipients receiving an increased mean dose rate of total irradiation

    International Nuclear Information System (INIS)

    Ringden, O.; Baaryd, I.; Johansson, B.

    1983-01-01

    Seven bone marrow transplant recipients with acute lymphoblastic leukemia receiving a mean dose rate of 0.07 Gy/min of total body irradiation towards the pelvic midpoint and the lungs had an increased (p<0.01) overall death rate of 86 per cent compared with 33 per cent among 27 patients with acute non-lymphoblastic leukemia or acute lymphoblastic leukemia treated with a mean dose rate of 0.04 Gy/min. Among the patients receiving the higher dose rate there was an increased mortality in causes related to radiation toxicity like early septicemia, interstitial pneumonitis and pulmonary fibrosis, compared with all patients receiving the lower dose rate (p<0.01) and also with 10 patients from this group with acute lymphoblastic leukemia (p<0.02). (Auth.)

  15. Clinical results of entrance dose in vivo dosimetry for high energy photons in external beam radiotherapy using MOSFETs

    International Nuclear Information System (INIS)

    Morton, J. P.; Bhat, M.; Williams, T.; Kovendy, A.

    2007-01-01

    Full text: Thomson and Nielsen T N -502 R D MOSFETs were used for entrance dose in vivo dosimetry for 6 and 10 MV photons. A total of 24 patients were tested, 10 breast. 8 prostate, 5 lung and 1 head and neck. For prostates three fields were checked. For all other plans all fields were checked. An action threshold of 8% was set for any one field and 5% for all fields combined. The total number of fields tested was 56, with a mean discrepancy of 1.4% and S.D. of 2.6%. Breasts had a mean discrepancy of 1.8% and S.D. of 2.8%. Prostates had a mean discrepancy of 1.3% and S.D. of 2.9%. For 3 fields combined, prostates had a mean of 1.3% and S.D. of 1.8%. These results are similar to results obtained with diodes and TLDs for the same techniques.

  16. beta. and. gamma. -comparative dose estimates on Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L. (California Univ., Livermore (USA). Lawrence Livermore National Lab.)

    1982-05-01

    Enewetak Atoll in the Pacific is used for atmospheric testing of U.S. nuclear weapons. Beta dose and ..gamma..-ray exposure measurements were made on two islands of the Enewetak Atoll during July-August 1976 to determine the ..beta.. and low energy ..gamma..-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a ..beta..-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to ..beta..- or low energy ..gamma..-contribution. The contribution at any particular site, however, is reduced by vegetation. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey. Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the ..beta..'s or low energy ..gamma..'s, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  17. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  18. Low-dose fractionated percutaneous teletherapy in age-related macular degeneration with subfoveolar neovascularization - 3 year results

    International Nuclear Information System (INIS)

    Schittkowski, M.; Schneider, H.; Guthoff, R.; Grueschow, K.; Ziegler, P.G.; Fietkau, R.

    2001-01-01

    The effect of low dose fractionated percutaneous teletherapy to visual acuity and the changes in subfoveolar neovascular membranes in age-related macular degeneration were investigated. Patients and Method: 126 eyes of 118 patients (age 55-89 years; mean 74 ys.) were treated. Best distal and near visual acuity was assessed prior to (= initial visual acuity [IVA]) and 3, 6, 12, 18, 24, and 36 months after teletherapy. Fluorescein angiography was performed prior to and 6, 12, 24 and 36 months after radiation therapy. For analysis patients were divided into different groups by IVA and membrane size. Maximal duration of observation was 36 months. Teletherapy was done by a 9-MeV photon linear accelerator through a lateral port in half-beam technique with a single dose of 2 Gy up to a total dose of 20 Gy within 12 days. Results: No severe negative side effects have been observed. Eight patients reported of epiphora and four patients complained of transient sicca syndrome. Visual acuity decreased more than one line in the group IVA 0.05-0.2. The group IVA 0.3-0.5 remained unchanged for 1 year. We found a tendency for increased visual acuity in group IVA ≥ 0.6 for 18 months. After that time both groups showed decreased visual acuity, but all these patients reported of reduced metamorphopsia and increased color and contrast perception. Conclusions: There is an influence of low dose fractionated percutaneous teletherapy on visual acuity, subfoveal neovascular membranes and metamorphopsia. IVA and duration of anamnesis play an important role. There seems to be no persistent effect; possibly increased dosage will bring a benefit. (orig.) [de

  19. Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H.; Streekstra, G.J.; Maas, M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Boomsma, M.F.; Osch, J.A.C. van [Department of Radiology, Zwolle (Netherlands); Vlassenbroek, A. [Philips Medical Systems, Brussels (Belgium); Milles, J. [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A. [Department of Innovation and Science, Zwolle (Netherlands); Slump, C.H. [University of Twente, MIRA Institute for Biomedical Technology and Technical Medicine, Enschede (Netherlands)

    2017-05-15

    To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. Scans were acquired from high- to low-dose (CTDI{sub vol}: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose{sup 4} level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose{sup 4} in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose{sup 4} in the CT imaging of a THA phantom. (orig.)

  20. Intraoperative low-dose ketamine infusion reduces acute postoperative pain following total knee replacement surgery: a prospective, randomized double-blind placebo-controlled trial.

    Science.gov (United States)

    Cengiz, Pelin; Gokcinar, Derya; Karabeyoglu, Isil; Topcu, Hulya; Cicek, Gizem Selen; Gogus, Nermin

    2014-05-01

    To evaluate the effect of intraoperative low-dose ketamine with general anesthesia on postoperative pain after total knee replacement surgery. A randomized, double-blind comparative study. Ankara Numune Training and Research Hospital, Turkey, from January and June 2011. Sixty adults undergoing total knee arthroplasty were enrolled in this study. The patients were randomly allocated into two groups of equal size to receive either racemic ketamine infusion (6 μg/kg/minute) or the same volume of saline. A visual analogue scale (VAS) was used to measure each patient's level of pain at 1, 3, 6, 12, and 24 hours after surgery. Time to first analgesic request, postoperative morphine consumption and the incidence of side effects were also recorded. Low-dose ketamine infusion prolonged the time to first analgesic request. It also reduced postoperative cumulative morphine consumption at 1, 3, 6, 12, and 24 hours postsurgery (p < 0.001). Postoperative VAS scores were also significantly lower in the ketamine group than placebo, at all observation times. Incidences of side effects were similar in both study groups. Intraoperative continuous low-dose ketamine infusion reduced pain and postoperative analgesic consumption without affecting the incidence of side effects.

  1. Calculation of doses received while crossing a plume of radioactive material

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Desrosiers, A.E.

    1981-04-01

    A method has been developed for determining the dose received by a person while crossing a plume of radioactive material. The method uses a Gaussian plume model to arrive at a dose rate on the plume centerline at the position of the plume crossing. This dose rate may be due to any external or internal dose pathway. An algebraic formula can then be used to convert the plume centerline dose rate to a total dose integrated over the total time of plume crossing. Correction factors are presented for dose pathways in which the dose rate is not normally distributed about the plume centerline. The method is illustrated by a study done at the Pacific Northwest Laboratory, and results of this study are presented

  2. Estimation of the committed radiation dose resulting from gamma radionuclides ingested with food

    International Nuclear Information System (INIS)

    Piotr Godyn; Agnieszka Dolhanczuk-Srodka; Zbigniew Ziembik; Ewa Moliszewska

    2014-01-01

    The objective of the study was to estimate the value of the radiation dose absorbed in consequence of consumption of popular food products for individual age groups. Potatoes, corn and sugar beet were selected for the study. Edible parts of these plants were collected in experimental fields of the KWS Lochow Polska Sp. z o.o. seeding company in Kondratowice (Poland). On the basis of the obtained study results, it can be stated that in consequence of consumption of the selected food products, people may receive increased doses from both natural and artificial radioactive isotopes. The doses calculated for several age groups do not show any health hazards in consequence of consumption of the tested food. One of the determined radionuclides was 137 Cs; however, its presence in the absorbed dose is lower than the doses from natural radioactive isotopes, in particular 40 K. (author)

  3. Evaluation of radiation dose resulting from the ingestion of [3H]-and [14C]thymidine in the rat

    International Nuclear Information System (INIS)

    Takeda, H.; Iwakura, T.

    1987-01-01

    Average doses to rat tissues from the ingestion of 2-[ 14 C]thymidine were compared with those from methyl-[ 3 H]thymidine or 6-[ 3 H]thymidine. [ 14 C]thymidine gave the highest dose to spleen and small intestine. Doses to other tissues from [ 14 ]thymidine were almost the same or lower compared with those from [ 3 H]thymidine, irrespective of the 9 times higher β-ray energy of 14 C than that of 3 H. In the case of [ 14 C]thymidine, most of the dose was given by radioactivity incorporated into the organic tissue constituents (non-volatile radioactivity). In the case of [ 3 H]thymidine, the dose contributions by non-volatile radioactivity were very small and major contributions were rather from volatile radioactivity ( 3 HHO), formed by degradation of [ 3 H]thymidine. No significant difference in their total doses was found between the two [ 3 H]precursors, but the dose from non-volatile radioactivity alone was 2-3 times higher with methyl-[ 3 H]thymidine than with 6-[ 3 H]thymidine. Estimates of dose to cell nuclei in various tissues after ingestion of [ 3 H]thymidine were also made in order to predict more precisely possible radiation hazards. (author)

  4. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  5. Cosmetic results in early stage breast cancer patients with high-dose brachytherapy after conservative surgery

    International Nuclear Information System (INIS)

    Torres, Felipe; Pineda, Beatriz E

    2004-01-01

    Purpose: to reveal cosmetic results in patients at early stages of low risk breast cancer treated with partial accelerated radiotherapy using high dose rate brachytherapy. Methods and materials: from March 2001 to July 2003,14 stages l and ll breast cancer patients were treated at the Colombian national cancer institute in Bogota with conservative surgery and radiotherapy upon the tumor bed (partial accelerated radiotherapy), using interstitial implants with iridium 192 (high dose rate brachytherapy) with a dose of 32 Gys, over 4 days, at 8 fractions twice a day. Results: with an average follow up of 17.7 months, good cosmetic results were found among 71.4 % of patients and excellent results among 14.3% of patients, furthermore none of the patients neither local nor regional or distant relapses. Conclusion: among patients who suffer from breast cancer at early stages, it showed is possible to apply partial accelerated radiotherapy upon the tumor bed with high doses over 4 days with good to excellent cosmetic results

  6. Time-dose modifications

    International Nuclear Information System (INIS)

    Kian Ang, K.

    1987-01-01

    Changes in fractionation schedule can be made by various approaches. However, from the first principle, it is anticipated that strategies of hyperfractionation and/or accelerated fractionation offer the most promised in improving the therapeutic ratio. Hyperfractionation is defined as a treatment schedule in which a large number of significantly reduced dose fractions (--1.2 Gy/fraction) is used to give a greater total dose in a conventional overall time period. The results of the pilot studies testing the efficacy of hyperfractionation have been encouraging. The most valid clinical trial of pure hyperfractionation, however, is that conducted by the EORTC. This study compared 70 Gy in 35 fractions or 80.5 Gy in 70 fractions over 7 weeks in the treatment of patients with oropharyngeal carcinomas. The local tumor control was significantly improved in the hyperfractionated arm without increasing the morbidity. Accelerated fractionation is defined as a schedule in which the overall time of treatment is reduced without significant changes in the total dose and fraction size. The strategy has been used to treat patients with malignant gliomas, melanomas and Head and Neck cancers. The data in Head and Neck Cancers seem to be promising

  7. Characterization of total ionizing dose damage in COTS pinned photodiode CMOS image sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn; Ma, Wuying; Huang, Shaoyan; Yao, Zhibin; Liu, Minbo; He, Baoping; Sheng, Jiangkun; Xue, Yuan [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, P.O.Box 69-10, Xi’an, Shaanxi 710024 (China); Liu, Jing [School of Materials Science and Engineering, Xiangtan University, Hunan (China)

    2016-03-15

    The characterization of total ionizing dose (TID) damage in COTS pinned photodiode (PPD) CMOS image sensors (CISs) is investigated. The radiation experiments are carried out at a {sup 60}Co γ-ray source. The CISs are produced by 0.18-μm CMOS technology and the pixel architecture is 8T global shutter pixel with correlated double sampling (CDS) based on a 4T PPD front end. The parameters of CISs such as temporal domain, spatial domain, and spectral domain are measured at the CIS test system as the EMVA 1288 standard before and after irradiation. The dark current, random noise, dark signal non-uniformity (DSNU), photo response non-uniformity (PRNU), overall system gain, saturation output, dynamic range (DR), signal to noise ratio (SNR), quantum efficiency (QE), and responsivity versus the TID are reported. The behaviors of the tested CISs show remarkable degradations after radiation. The degradation mechanisms of CISs induced by TID damage are also analyzed.

  8. Bayesian estimation of dose rate effectiveness

    International Nuclear Information System (INIS)

    Arnish, J.J.; Groer, P.G.

    2000-01-01

    A Bayesian statistical method was used to quantify the effectiveness of high dose rate 137 Cs gamma radiation at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice. The Bayesian approach considers both the temporal and dose dependence of radiation carcinogenesis and total mortality. This paper provides the first direct estimation of dose rate effectiveness using Bayesian statistics. This statistical approach provides a quantitative description of the uncertainty of the factor characterising the dose rate in terms of a probability density function. The results show that a fixed dose from 137 Cs gamma radiation delivered at a high dose rate is more effective at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice than the same dose delivered at a low dose rate. (author)

  9. Failure-probability driven dose painting

    International Nuclear Information System (INIS)

    Vogelius, Ivan R.; Håkansson, Katrin; Due, Anne K.; Aznar, Marianne C.; Kristensen, Claus A.; Rasmussen, Jacob; Specht, Lena; Berthelsen, Anne K.; Bentzen, Søren M.

    2013-01-01

    Purpose: To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study using the optimized dose prescription in 20 patients is performed.Methods: Patients treated at our center have five tumor subvolumes from the center of the tumor (PET positive volume) and out delineated. The spatial distribution of 48 failures in patients with complete clinical response after (chemo)radiation is used to derive a model for tumor control probability (TCP). The total TCP is fixed to the clinically observed 70% actuarial TCP at five years. Additionally, the authors match the distribution of failures between the five subvolumes to the observed distribution. The steepness of the dose–response is extracted from the literature and the authors assume 30% and 20% risk of subclinical involvement in the elective volumes. The result is a five-compartment dose response model matching the observed distribution of failures. The model is used to optimize the distribution of dose in individual patients, while keeping the treatment intensity constant and the maximum prescribed dose below 85 Gy.Results: The vast majority of failures occur centrally despite the small volumes of the central regions. Thus, optimizing the dose prescription yields higher doses to the central target volumes and lower doses to the elective volumes. The dose planning study shows that the modified prescription is clinically feasible. The optimized TCP is 89% (range: 82%–91%) as compared to the observed TCP of 70%.Conclusions: The observed distribution of locoregional failures was used to derive an objective, data-driven dose prescription function. The optimized dose is predicted to result in a substantial increase in local control without increasing the predicted risk of toxicity

  10. High dose rate versus low dose rate interstitial radiotherapy for carcinoma of the floor of mouth

    International Nuclear Information System (INIS)

    Inoue, Takehiro; Inoue, Toshihiko; Yamazaki, Hideya; Koizumi, Masahiko; Kagawa, Kazufumi; Yoshida, Ken; Shiomi, Hiroya; Imai, Atsushi; Shimizutani, Kimishige; Tanaka, Eichii; Nose, Takayuki; Teshima, Teruki; Furukawa, Souhei; Fuchihata, Hajime

    1998-01-01

    Purpose: Patients with cancer of the floor of mouth are treated with radiation because of functional and cosmetic reasons. We evaluate the treatment results of high dose rate (HDR) and low dose rate (LDR) interstitial radiation for cancer of the floor of mouth. Methods and Materials: From January 1980 through March 1996, 41 patients with cancer of the floor of mouth were treated with LDR interstitial radiation using 198 Au grains, and from April 1992 through March 1996 16 patients with HDR interstitial radiation. There were 26 T1 tumors, 30 T2 tumors, and 1 T3 tumor. For 21 patients treated with interstitial radiation alone, a total radiation dose of interstitial therapy was 60 Gy/10 fractions/6-7 days in HDR and 85 Gy within 1 week in LDR. For 36 patients treated with a combination therapy, a total dose of 30 to 40 Gy of external radiation and a total dose of 48 Gy/8 fractions/5-6 days in HDR or 65 Gy within 1 week in LDR were delivered. Results: Two- and 5-year local control rates of patients treated with HDR interstitial radiation were 94% and 94%, and those with LDR were 75% and 69%, respectively. Local control rate of patients treated with HDR brachytherapy was slightly higher than that with 198 Au grains (p = 0.113). For late complication, bone exposure or ulcer occurred in 6 of 16 (38%) patients treated with HDR and 13 of 41 (32%) patients treated with LDR. Conclusion: HDR fractionated interstitial brachytherapy can be an alternative to LDR brachytherapy for cancer of the floor of mouth and eliminate radiation exposure for the medical staff

  11. Noise reduction technology reduces radiation dose in chronic total occlusions percutaneous coronary intervention: a propensity score-matched analysis.

    Science.gov (United States)

    Maccagni, Davide; Benincasa, Susanna; Bellini, Barbara; Candilio, Luciano; Poletti, Enrico; Carlino, Mauro; Colombo, Antonio; Azzalini, Lorenzo

    2018-03-23

    Chronic total occlusions (CTO) percutaneous coronary intervention (PCI) is associated with high radiation dose. Our study aim was to evaluate the impact of the implementation of a noise reduction technology (NRT) on patient radiation dose during CTO PCI. A total of 187 CTO PCIs performed between February 2016 and May 2017 were analyzed according to the angiographic systems utilized: Standard (n = 60) versus NRT (n = 127). Propensity score matching (PSM) was performed to control for differences in baseline characteristics. Primary endpoints were Cumulative Air Kerma at Interventional Reference Point (AK at IRP), which correlates with patient's tissue reactions; and Kerma Area Product (KAP), a surrogate measure of patient's risk of stochastic radiation effects. An Efficiency Index (defined as fluoroscopy time/AK at IRP) was calculated for each procedure. Image quality was evaluated using a 5-grade Likert-like scale. After PSM, n = 55 pairs were identified. Baseline and angiographic characteristics were well matched between groups. Compared to the Standard system, NRT was associated with lower AK at IRP [2.38 (1.80-3.66) vs. 3.24 (2.04-5.09) Gy, p = 0.035], a trend towards reduction for KAP [161 (93-244) vs. 203 (136-363) Gycm 2 , p = 0.069], and a better Efficiency Index [16.75 (12.73-26.27) vs. 13.58 (9.92-17.63) min/Gy, p = 0.003]. Image quality was similar between the two groups (4.39 ± 0.53 Standard vs. 4.34 ± 0.47 NRT, p = 0.571). In conclusion, compared with a Standard system, the use of NRT in CTO PCI is associated with lower patient radiation dose and similar image quality.

  12. Investigation of the impact of dose fluctuations on tumour control

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.; Royal Adelaide Hospital,; Booth, J.; Adelaide University,; Rosenfeld, A.

    2001-01-01

    Full text: The importance of spatial uniformity of the dose across the Planning Target Volume (PTV) has been investigated previously with the conclusion stated in 'uniform dose theorem' concluding that the uniform dose results in the highest Tumour Control Probability (TCP). The dose fluctuations, which appear in fractionated treatments as a result of setup errors, organ motion, treatment machine calibration and other reasons can be seen as temporal dose non-uniformity. The intuitive expectation, that the temporal dose non-uniformity would also reduce TCP, has been tested. The impact of temporal dose non-uniformity has been investigated considering intra and inter-treatment dose fluctuations. The dose was considered to be spatially uniform. The convolution technique was used and analytical expression of TCP accounting for the dose fluctuation has also been derived. Both techniques used Probability Density Function (PDF) to account for the dose fluctuations. The dose fluctuations with PDF symmetrical around its mean value (Gaussian) as well as non-symmetrical PDFs were both investigated. The symmetrical PDFs represented the fluctuations, which appear in the whole PTV as a result of day to day variation in treatment machine output. Non-symmetrical PDFs represented the dose fluctuations at the edges of PTV as a result of setup errors and organ motion. The effect of the dose fluctuations has been expressed in terms of an extra dose δ (positive or negative) which should be added to the value of temporally uniform dose in order to provide the same TCP as the one resulting from temporally non-uniform (fluctuating) dose. Intra-treatment dose fluctuations resulted in an increased TCP, though the effect is relatively small (δ<1 Gy for the treatment dose of 60 Gy). However, inter-treatment fluctuations of the dose reduced TCP for a patient population. The size of effect increases with the standard deviation of the PDF. Random ultra-treatment dose fluctuations resulted in

  13. [Ranking of radionuclides and pathways according to their contribution to the dose burden to the population resulting from NPP releases].

    Science.gov (United States)

    Spiridonov, S I; Karpenko, E I; Sharpan, L A

    2013-01-01

    Approaches are described towards estimating the consequences of radioactive contamination of ecosystems by nuclear fuel cycle enterprises with the rationale for the optimal specification level for nuclear power plants (NPP) operating in the normal mode. Calculations are made based on the initial data of the IAEA project, INPRO ENV, dealing with the ranking of radionuclides escaping to the environment from the operating NPPs. Influence of various factors on rankings of radionuclides and pathways of public exposure is demon- strated. An important factor is the controlled radionuclide composition of atmospheric NPP releases. It has been found that variation in the dose coefficients for some radionuclides leads to significant changes not only in the ranking results but also in the estimates of total dose burdens. Invariability is shown of the estimation concerning the greatest contribution of the peroral route to the population dose of irradiation in the situation considered. A conclusion was drawn on the need of taking into consideration uncertainties of different factors when comparing effects on the environment from enterprises of conventional and innovative nuclear fuel cycles.

  14. The effect of dose, dose rate, route of administration, and species on tissue and blood levels of benzene metabolites

    International Nuclear Information System (INIS)

    Henderson, R.F.; Sabourin, P.J.; Bechtold, W.E.; Griffith, W.C.; Medinsky, M.A.; Birnbaum, L.S.; Lucier, G.W.

    1989-01-01

    Studies were completed in F344/N rats and B6C3F 1 mice to determine the effect of dose, dose rate, route of administration, and rodent species on formation of total and individual benzene metabolites. Oral doses of 50 mg/kg or higher saturated the capacity for benzene metabolism in both rats and mice, resulting in an increased proportion of the administered dose being exhaled as benzene. The saturating air concentration for benzene metabolism during 6-hr exposures was between 130 and 900 ppm. At the highest exposure concentration, rats exhaled approximately half of the internal dose retained at the end of the 6-hr exposure as benzene; mice exhaled only 15% as benzene. Mice were able to convert more of the inhaled benzene to metabolites than were rats. In addition, mice metabolized more of the benzene by pathways leading to the putative toxic metabolites, benzoquinone and muconaldehyde, than did rats. In both rats and mice, the effect of increasing dose, administered orally or by inhalation, was to increase the proportion of the total metabolites that were the products of detoxification pathways relative to the products of pathways leading to putative toxic metabolites. This indicates low-affinity, high-capacity pathways for detoxification and high-affinity, low-capacity pathways leading to putative toxic metabolites. If the results of rodent studied performed at high doses were used to assess the health risk at low-dose exposures to benzene, the toxicity of benzene would be underestimated

  15. The Relative Effects of Manual Versus Automatic Exposure Control on Radiation Dose to Vital Organs in Total Hip Arthroplasty.

    Science.gov (United States)

    Harper, Katharine D; Li, Shidong; Jennings, Rachel; Amer, Kamil M; Haydel, Christopher; Ali, Sayed

    2018-01-01

    Technologic advances have reduced medical radiation exposure while maintaining image quality. The purpose of this study was to determine the effects of the presence of total hip arthroplasty implants, compared with native hips, on radiation exposure of the most radiosensitive organs when manual and automatic exposure control settings are used. Detection probes were placed at six locations (stomach, sigmoid colon, right pelvic wall, left pelvic wall, pubic symphysis, and anterior pubic skin) in a cadaver. Radiographs were obtained with the use of manual and automatic exposure control protocols, with exposures recorded. A total hip arthroplasty implant was placed in the cadaver, probe positioning was confirmed, and the radiographs were repeated, with exposure values recorded. The control probe placed at the stomach had values ranging from 0.00 mSv to 0.01 mSv in protocols with and without implants. With the manual protocol, exposures in the pelvis ranged from 0.36 mSv to 2.74 mSv in the native hip and from 0.33 mSv to 2.24 mSv after implant placement. The increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 0.818; left pelvic wall, 1.381; sigmoid colon, 1.550; right pelvic wall, 0.917; and anterior pubic skin, 1.015. With automatic exposure control, exposures in the pelvis ranged from 0.07 mSv to 0.89 mSv in the native hip and from 0.21 mSv to 1.15 mSv after implant placement. With automatic exposure control, the increases in exposure after implant placement, represented as relative risk, were as follows: stomach, 1.000; pubic symphysis, 1.292; left pelvic wall, 1.476; sigmoid colon, 2.182; right pelvic wall, 3.000; and anterior pubic skin, 1.378. The amount of radiation to which patients are exposed as a result of medical procedures or imaging, and whether exposure is associated with an increased risk of malignant transformation, are the subject of ongoing debate. We found that after insertion

  16. Fluorouracil and high-dose leucovorin with radiotherapy as adjuvant therapy for rectal cancer. Results of a phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Giralt, J. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rubio, D. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Maldonado, X. [Radiation Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Naval, J. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Casado, S. [Medical Oncology Service, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Lara, F. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Rosello, J.M. [Dept. of Preventive Medicine, Hospital General Universitari Vall d`Hebron, Barcelona (Spain); Armengol, M. [Dept. of Surgery, Hospital General Universitari Vall d`Hebron, Barcelona (Spain)

    1997-07-01

    The purpose of this phase II study was to evaluate the efficacy and toxicity of fluorouracil and high-dose leucovorin (5-FU/LV) with pelvic irradiation as adjuvant therapy for patients with macroscopical resected rectal or recto-sigmoid cancer. Following surgery for stages II-III primary (52) or recurrent rectal cancer (4), 56 patients received 8 cycles of 5-FU/LV and pelvic irradiation. 5-FU doses were 200 mgr/m{sup 2} for cycles 2-3 and 300 mgr/m{sup 2} for cycles 1 and 4-8. LV doses remained fixed at 200 mgr/m{sup 2}. Pelvic radiation was started in the third week, between the first and second cycle. The total dose was 50.4 Gy. No serve complications had been recorded. The incidence of grade 3 diarrhea was 19%. Three patients presented leukopenia grade 3 (5%). In 44 patients (78%) the planned treatment could be administered. The median follow-up was 40 months (range 22-66). Seven patients had a local relapse (13%) and 6 developed distant metastasis (10%). The 3-year disease-free survival was 72% and the overall survival was 76%. These preliminary results show that combined post-operative 5-FU/LV and pelvic radiotherapy are well tolerated and present a reasonable local control and survival rates. This adjuvant treatment should be evaluated in randomized trials. (orig.).

  17. Final toxicity results of a radiation-dose escalation study in patients with non-small-cell lung cancer (NSCLC): Predictors for radiation pneumonitis and fibrosis

    International Nuclear Information System (INIS)

    Kong, F.-M.; Hayman, James A.; Griffith, Kent A.; Kalemkerian, Gregory P.; Arenberg, Douglas; Lyons, Susan; Turrisi, Andrew; Lichter, Allen; Fraass, Benedick; Eisbruch, Avraham; Lawrence, Theodore S.; Haken, Randall K. ten

    2006-01-01

    Purpose: We aimed to report the final toxicity results on a radiation-dose escalation trial designed to test a hypothesis that very high doses of radiation could be safely administered to patients with non-small-cell lung cancer (NSCLC) by quantifying the dose-volume toxicity relationship of the lung. Methods and Materials: A total of 109 patients with unresectable or medically inoperable NSCLC were enrolled and treated with radiation-dose escalation (on the basis of predicted normal-lung toxicity) either alone or with neoadjuvant chemotherapy by use of 3D conformal techniques. Eighty-four patients (77%) received more than 69 Gy, the trial was stopped after the dose reached 103 Gy. Estimated median follow-up was 110 months. Results: There were 17 (14.6%) Grade 2 to 3 pneumonitis and 15 (13.8%) Grade 2 to 3 fibrosis and no Grade 4 to 5 lung toxicity. Multivariate analyses showed them to be (1) not associated with the dose prescribed to the tumor, and (2) significantly (p < 0.001) associated with lung-dosimetric parameters such as the mean lung dose (MLD), volume of lung that received at least 20 Gy (V20), and the normal-tissue complication probability (NTCP) of the lung. If cutoffs are 30% for V20, 20 Gy for MLD, and 10% for NTCP, these factors have positive predictive values of 50% to 71% and negative predictive value of 85% to 89%. Conclusions: With long-term follow-up for toxicity, we have demonstrated that much higher doses of radiation than are traditionally administered can be safely delivered to a majority of patients with NSCLC. Quantitative lung dose-volume toxicity-based dose escalation can form the basis for individualized high-dose radiation treatment to maximize the therapeutic ratio in these patients

  18. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 {approx} 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 {approx} 50.4 Gy (median: 50.4 Gy) over 5 {approx} 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 {approx} 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy{sub 10} (range:77 {approx} 94 Gy{sub 10}). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy{sub 3} (range: 122 {approx} 140 Gy{sub 3}) at point A, 109 Gy{sub 3} (range:88{approx} 125 Gy{sub 3}) at the rectum and 111 Gy{sub 3} (range: 91 {approx} 123 Gy{sub 3}) at the urinary bladder. Cisplatin (60 mg/m{sup 2}) and 5-FU (1,000 mg/m{sup 2}) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 {approx} 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8{approx} 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure

  19. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk

    2006-01-01

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 ∼ 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 ∼ 50.4 Gy (median: 50.4 Gy) over 5 ∼ 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 ∼ 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy 10 (range:77 ∼ 94 Gy 10 ). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy 3 (range: 122 ∼ 140 Gy 3 ) at point A, 109 Gy 3 (range:88∼ 125 Gy 3 ) at the rectum and 111 Gy 3 (range: 91 ∼ 123 Gy 3 ) at the urinary bladder. Cisplatin (60 mg/m 2 ) and 5-FU (1,000 mg/m 2 ) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 ∼ 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8∼ 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic

  20. Mesorad dose assessment model. Volume 1. Technical basis

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; Bander, T.J.; Athey, G.F.; Ramsdell, J.V.

    1986-03-01

    MESORAD is a dose assessment model for emergency response applications. Using release data for as many as 50 radionuclides, the model calculates: (1) external doses resulting from exposure to radiation emitted by radionuclides contained in elevated or deposited material; (2) internal dose commitment resulting from inhalation; and (3) total whole-body doses. External doses from airborne material are calculated using semi-infinite and finite cloud approximations. At each stage in model execution, the appropriate approximation is selected after considering the cloud dimensions. Atmospheric processes are represented in MESORAD by a combination of Lagrangian puff and Gaussian plume dispersion models, a source depletion (deposition velocity) dry deposition model, and a wet deposition model using washout coefficients based on precipitation rates

  1. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  2. Responses of rat R-1 cells to low dose rate gamma radiation and multiple daily dose fractions

    International Nuclear Information System (INIS)

    Kal, H.B.; Bijman, J.Th.

    1981-01-01

    Multifraction irradiation may offer the same therapeutic gain as continuous irradiation. Therefore, a comparison of the efficacy of low dose rate irradiation and multifraction irradiation was the main objective of the experiments to be described. Both regimens were tested on rat rhabdomyosarcoma (R-1) cells in vitro and in vivo. Exponentially growing R-1 cells were treated in vitro by a multifraction irradiation procedure with dose fractions of 2 Gy gamma radiation and time intervals of 1 to 3 h. The dose rate was 1.3 Gy.min -1 . The results indicate that multifractionation of the total dose is more effective with respect to cell inactivation than continuous irradiation. (Auth.)

  3. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma: an open clinical study and pooled data analysis.

    Science.gov (United States)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars; Skov, Lone; Petersen, Peter Meidahl; Loft, Annika; Specht, Lena

    2015-05-01

    Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments is limited to 2 to 3 courses in a lifetime due to skin toxicity. This study aimed to determine the clinical effect of low-dose TSEBT in patients with MF and SS. In an open clinical study, 21 patients with MF/SS stages IB to IV were treated with low-dose TSEBT over dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. The overall response rate was 95% with a complete cutaneous response or a very good partial response rate (dose (10-Gy) TSEBT offers a high overall response rate and is relatively safe. With this approach, reirradiation at times of relapse or progression is likely to be less toxic than standard dose TSEBT. It remains to be established whether adjuvant and combination treatments can prolong the beneficial effects of low-dose TSEBT. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Reduced-intensity conditioning regimen using low-dose total body irradiation before allogeneic transplant for hematologic malignancies: Experience from the European Group for Blood and Marrow Transplantation

    International Nuclear Information System (INIS)

    Belkacemi, Yazid; Labopin, Myriam; Hennequin, Christophe; Hoffstetter, Sylvette; Mungai, Raffaello; Wygoda, Marc; Lundell, Marie; Finke, Jurgen; Aktinson, Chris; Lorchel, Frederic; Durdux, Catherine; Basara, Nadezda

    2007-01-01

    Purpose: The high rate of toxicity is the limitation of myelobalative regimens before allogeneic transplantation. A reduced intensity regimen can allow engraftment of stem cells and subsequent transfer of immune cells for the induction of a graft-vs.-tumor reaction. Methods and Materials: The data from 130 patients (80 males and 50 females) treated between 1998 and 2003 for various hematologic malignancies were analyzed. The median patient age was 50 years (range, 3-72 years). Allogeneic transplantation using peripheral blood or bone marrow, or both, was performed in 104 (82%), 22 (17%), and 4 (3%) patients, respectively, from HLA identical sibling donors (n = 93, 72%), matched unrelated donors (n = 23, 18%), mismatched related donors (4%), or mismatched unrelated donors (6%). Total body irradiation (TBI) at a dose of 2 Gy delivered in one fraction was given to 101 patients (78%), and a total dose of 4-6 Gy was given in 29 (22%) patients. The median dose rate was 14.3 cGy/min (range, 6-16.4). Results: After a median follow-up period of 20 months (range, 1-62 months), engraftment was obtained in 122 patients (94%). Acute graft-vs.-host disease of Grade 2 or worse was observed in 37% of patients. Multivariate analysis showed three favorable independent factors for event-free survival: HLA identical sibling donor (p < 0.0001; relative risk [RR], 0.15), complete remission (p < 0.0001; RR, 3.08), and female donor to male patient (p = 0.006; RR 2.43). For relapse, the two favorable prognostic factors were complete remission (p < 0.0001, RR 0.11) and HLA identical sibling donor (p = 0.0007; RR 3.59). Conclusions: In this multicenter study, we confirmed high rates of engraftment and chimerism after the reduced intensity regimen. Our results are comparable to those previously reported. Radiation parameters seem to have no impact on outcome. However, the lack of a statistically significant difference in terms of dose rate may have been due, in part, to the small population

  5. Method to account for dose fractionation in analysis of IMRT plans: Modified equivalent uniform dose

    International Nuclear Information System (INIS)

    Park, Clinton S.; Kim, Yongbok; Lee, Nancy; Bucci, Kara M.; Quivey, Jeanne M.; Verhey, Lynn J.; Xia Ping

    2005-01-01

    Purpose: To propose a modified equivalent uniform dose (mEUD) to account for dose fractionation using the biologically effective dose without losing the advantages of the generalized equivalent uniform dose (gEUD) and to report the calculated mEUD and gEUD in clinically used intensity-modulated radiotherapy (IMRT) plans. Methods and Materials: The proposed mEUD replaces the dose to each voxel in the gEUD formulation by a biologically effective dose with a normalization factor. We propose to use the term mEUD D o /n o that includes the total dose (D o ) and number of fractions (n o ) and to use the term mEUD o that includes the same total dose but a standard fraction size of 2 Gy. A total of 41 IMRT plans for patients with nasopharyngeal cancer treated at our institution between October 1997 and March 2002 were selected for the study. The gEUD and mEUD were calculated for the planning gross tumor volume (pGTV), planning clinical tumor volume (pCTV), parotid glands, and spinal cord. The prescription dose for these patients was 70 Gy to >95% of the pGTV and 59.4 Gy to >95% of the pCTV in 33 fractions. Results: The calculated average gEUD was 72.2 ± 2.4 Gy for the pGTV, 54.2 ± 7.1 Gy for the pCTV, 26.7 ± 4.2 Gy for the parotid glands, and 34.1 ± 6.8 Gy for the spinal cord. The calculated average mEUD D o /n o using 33 fractions was 71.7 ± 3.5 Gy for mEUD 70/33 of the pGTV, 49.9 ± 7.9 Gy for mEUD 59.5/33 of the pCTV, 27.6 ± 4.8 Gy for mEUD 26/33 of the parotid glands, and 32.7 ± 7.8 Gy for mEUD 45/33 of the spinal cord. Conclusion: The proposed mEUD, combining the gEUD with the biologically effective dose, preserves all advantages of the gEUD while reflecting the fractionation effects and linear and quadratic survival characteristics

  6. Evolution of doses in the IEA-R1/NRR environment and tendencies based on the current results

    International Nuclear Information System (INIS)

    Toyoda, Eduardo Yoshio; Sordi, Gian-Maria; Vaz, Antonio C.A.

    2015-01-01

    The IPEN / CNEN-SP has a Nuclear Research Reactor-NRR named IEA-R1, in operation since 1957. Until 1995 the reactor operated daily at a power of 2,0 MW. From June of that year, after a few safety modifications the reactor began operating in continuous way from Monday to Wednesday without shutdown totaling 64 hours per week, also the power was increased until 4,5MW in 2012. Because of these changes, continuous operation and increased power, workers' doses increased. In the past, several studies were conducted seeking ways to reduce the workers' doses. The purpose of this paper is to analyze the individual doses of OEI (occupationally exposed individual), considering the changes in reactor operation mode and to suggest the viable protection and safety options, in the first instance to reduce the doses in question aimed at the goal of reaching acceptable region, that is, lower or at most equal to 5 mSv / year for the International Commission on Radiological Protection(ICRP). (author)

  7. 8 Gy single-dose radiotherapy is effective in metastatic spinal cord compression: Results of a phase III randomized multicentre Italian trial

    International Nuclear Information System (INIS)

    Maranzano, Ernesto; Trippa, Fabio; Casale, Michelina; Costantini, Sara; Lupattelli, Marco; Bellavita, Rita; Marafioti, Luigi; Pergolizzi, Stefano; Santacaterina, Anna; Mignogna, Marcello; Silvano, Giovanni; Fusco, Vincenzo

    2009-01-01

    Background and purpose: In a previous randomized trial we showed that the short-course radiotherapy (RT) regimen of 8 Gy x 2 was feasible in patients with metastatic spinal cord compression (MSCC) and short life expectancy. This phase III trial was planned to determine whether in the same category of patients 8 Gy single-dose is as effective as 8 Gy x 2. Materials and methods: Three hundred and twenty-seven patients with MSCC and short life expectancy were randomly assigned to a short-course of 8 Gy x 2 or to 8 Gy single-dose RT. Median follow-up was 31 months (range, 4-58). Results: A total of 303 (93%) patients are assessable, 150 treated with the short-course and 153 with the single-dose RT. No difference in response was found between the two RT schedules adopted. Median duration of response was 5 and 4.5 months for short-course and single-dose RT (p = 0.4), respectively. The median overall survival was 4 months for all cases. Light acute toxicity was registered in a minority of cases. Late toxicity was never recorded. Conclusions: Both RT schedules adopted were effective. As already shown in several trials evaluating RT regimens in uncomplicated painful bone metastases, also MSCC patients may achieve palliation with minimal toxicity and inconvenience with a single-dose of 8 Gy.

  8. Total Flavonoids from Mimosa Pudica Protects Carbon Tetrachloride -Induced Acute Liver Injury in Mice

    Directory of Open Access Journals (Sweden)

    Zhen-qin QIU

    2015-03-01

    Full Text Available Objective: To observe the protective effect of total flavonoids from Mimosa pudica on carbon tetrachloride (CCl4-induced acute liver injury in mice. Methods: CCl4-induced acute liver injury model in mice was established. The activity of ALT and AST, the content of serum albumin (Alb and total antioxidant capacity (T-AOC were determined. The content of malondiadehyde (MDA was measured and the activity of superoxide dismutase (SOD was determined. The histopathological changes of liver were observed.Results: Compared with CCl4 modle group, each dose group of total flavonouida from Mimosa pudica couldreduced the activity of ALT and AST in mice obviously (P<0.01, indicating they had remarkably protective effect on CCl4-induced acute liver injury in mice. high and middle dose groups of total flavonouida from Mimosa pudica couldincrease the content of Alb in mice (P<0.01. Each dose group of total flavonouida from Mimosa pudica could enhance the level of T-AOC (P<0.01. each dose group of total flavonouida from Mimosa pudica could lower the content of liver homogenate MDA but enhance the activity of SOD in a dose-depended manner (P<0.01. Conclusion: Total flavones from Mimosa Pudica have obvious protective effect on CCl4-induced acute liver injury in mice.

  9. Differences in Clinical Results After LINAC-Based Single-Dose Radiosurgery Versus Fractionated Stereotactic Radiotherapy for Patients With Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Welzel, Thomas; Schulz-Ertner, Daniela; Huber, Peter E.; Debus, Juergen

    2010-01-01

    Purpose: To evaluate the outcomes of patients with vestibular schwannoma (VS) treated with fractionated stereotactic radiotherapy (FSRT) vs. those treated with stereotactic radiosurgery (SRS). Methods and Materials: This study is based on an analysis of 200 patients with 202 VSs treated with FSRT (n = 172) or SRS (n = 30). Patients with tumor progression and/or progression of clinical symptoms were selected for treatment. In 165 out of 202 VSs (82%), RT was performed as the primary treatment for VS, and for 37 VSs (18%), RT was conducted for tumor progression after neurosurgical intervention. For patients receiving FSRT, a median total dose of 57.6 Gy was prescribed, with a median fractionation of 5 x 1.8 Gy per week. For patients who underwent SRS, a median single dose of 13 Gy was prescribed to the 80% isodose. Results: FSRT and SRS were well tolerated. Median follow-up time was 75 months. Local control was not statistically different for both groups. The probability of maintaining the pretreatment hearing level after SRS with doses of ≤13 Gy was comparable to that of FSRT. The radiation dose for the SRS group (≤13 Gy vs. >13 Gy) significantly influenced hearing preservation rates (p = 0.03). In the group of patients treated with SRS doses of ≤13 Gy, cranial nerve toxicity was comparable to that of the FSRT group. Conclusions: FSRT and SRS are both safe and effective alternatives for the treatment of VS. Local control rates are comparable in both groups. SRS with doses of ≤13 Gy is a safe alternative to FSRT. While FSRT can be applied safely for the treatment of VSs of all sizes, SRS should be reserved for smaller lesions.

  10. Comparison of three techniques for skin total irradiation with electrons; Comparacao de tres tecnicas de irradiacao total da pele com eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Delano V.S., E-mail: dbatista@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Bardella, Lucia H. [Instituto Nacional de Cancer (INCa), Rio de Janeiro, RJ (Brazil); Rosa, Luiz A.R. da, E-mail: lrosa@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    This paper compared three techniques of skin total irradiation with electrons: 1) horizontal positioning, 2) vertical positioning - rotatory technique and 3) vertical positioning - six fields technique. For that, a anthropomorphic phantom was positioned according to the recommendation for each technique and was i radiated at the linear accelerator by using the 6 MeV electrons. Radiochromic films were positioned on the surface in various regions of the phantom for measurement of absorbed dose. A ionization chamber was positioned inside of equivalent issue plates for dose evaluation due to the photons produced by electron stopping. The technique 2 and 3 have shown too similar in the results and number or discrepant points (8 and 10 respectively) of prescription lower than the technique 1 (22 points). The total body dose of photons of the 1, 2 and 3 techniques was 2.2%, 5.3% and 5.2% respectively

  11. Hyperfractionated conformal radiotherapy in locally advanced prostate cancer: results of a dose escalation study

    International Nuclear Information System (INIS)

    Forman, Jeffrey D.; Duclos, Marie; Shamsa, Falah; Porter, Arthur T.; Orton, Colin

    1996-01-01

    Purpose: This study was initiated to assess the incidence of chronic complications and histologic and biochemical control following hyperfractionated conformal radiotherapy in patients with locally advanced prostate cancer. Methods and Materials: Between October 1991 and October 1994, 49 patients with locally advanced prostate cancer were entered on the first two dose levels of a prospective dose-escalation study using hyperfractionated three dimensional conformal radiotherapy. The first 25 patients received a minimum tumor dose of 78 Gy to the prostate and seminal vesicles in 6 weeks at 1.3 Gy, b.i.d. No increase in chronic toxicity compared with conventional radiotherapy was noted; therefore, an additional 24 patients were treated to a minimum tumor dose of 82.8 Gy to the prostate and seminal vesicles in 7 weeks at 1.15 Gy, b.i.d. Toxicity was scored according to the Radiation Therapy Oncology Group morbidity grading scale. Efficacy was assessed through scheduled postradiation prostate specific antigen values and ultrasound-guided biopsies. The median follow-up for the entire group was 20 months. Results: The hyperfractionated external radiation was well tolerated with minimal acute morbidity. At 30 months, the actuarial probability of Grade 2 gastrointestinal toxicity was 17%. At 30 months, the actuarial probability of Grade 2 genitourinary toxicity was 16%. There was no statistically significant difference between the two dose levels. No Grade 3 or 4 gastrointestinal or genitourinary toxicity was noted. At 12 months, 84% of patients had a prostate specific antigen ≤ 4; and 53%; ≤ 1 ng/ml. At 12 months, 71% of patients had post radiation biopsies that were either negative (55%) or showed a marked therapeutic effect (16%). Conclusion: The use of hyperfractionated conformal radiotherapy facilitated dose escalation with no increase in chronic toxicity compared to standard doses. The initial tumor response based on prostate specific antigen measurements and

  12. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    International Nuclear Information System (INIS)

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-01-01

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  13. beta- and gamma-Comparative dose estimates on Eniwetok Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Crase, K.W.; Gudiksen, P.H.; Robison, W.L.

    1982-05-01

    Eniwetok Atoll is one of the Pacific atolls used for atmospheric testing of U.S. nuclear weapons. Beta dose and gamma-ray exposure measurements were made on two islands of the Eniwetok Atoll during July-August 1976 to determine the beta and low energy gamma-contribution to the total external radiation doses to the returning Marshallese. Measurements were made at numerous locations with thermoluminescent dosimeters (TLD), pressurized ionization chambers, portable NaI detectors, and thin-window pancake GM probes. Results of the TLD measurements with and without a beta-attenuator indicate that approx. 29% of the total dose rate at 1 m in air is due to beta- or low energy gamma-contribution. The contribution at any particular site, however, is somewhat dependent on ground cover, since a minimal amount of vegetation will reduce it significantly from that over bare soil, but thick stands of vegetation have little effect on any further reductions. Integral 30-yr external shallow dose estimates for future inhabitants were made and compared with external dose estimates of a previous large scale radiological survey (En73). Integral 30-yr shallow external dose estimates are 25-50% higher than whole body estimates. Due to the low penetrating ability of the beta's or low energy gamma's, however, several remedial actions can be taken to reduce the shallow dose contribution to the total external dose.

  14. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, G. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  15. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    International Nuclear Information System (INIS)

    Jannik, G. T.; Dixon, K. L.

    2016-01-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  16. Research on total-dose hardening for H-gate PD NMOSFET/SIMOX by ion implanting into buried oxide

    International Nuclear Information System (INIS)

    Qian Cong; Zhang Zhengxuan; Zhang Feng; Lin Chenglu

    2008-01-01

    In this work, we investigate the back-gate I-V characteristics for two kinds of NMOSFET/SIMOX transistors with H gate structure fabricated on two different SOI wafers. A transistors are made on the wafer implanted with Si + and then annealed in N 2 , and B transistors are made on the wafer without implantation and annealing. It is demonstrated experimentally that A transistors have much less back-gate threshold voltage shift ΔV th than B transistors under X-ray total close irradiation. Subthreshold charge separation technique is employed to estimate the build-up of oxide charge and interface traps during irradiation, showing that the reduced ΔV th for A transistors is mainly due to its less build-up of oxide charge than B transistors. Photo-luminescence (PL) research indicates that Si implantation results in the formation of silicon nanocrystalline (nanocluster) whose size increases with the implant dose. This structure can trap electrons to compensate the positive charge build-up in the buried oxide during irradiation, and thus reduce the threshold voltage negative shift. (authors)

  17. Reirradiation for recurrent head and neck cancer with salvage interstitial pulsed-dose-rate brachytherapy. Long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Strnad, Vratislav; Lotter, Michael; Kreppner, Stephan; Fietkau, Rainer [University Hospital Erlangen, Dept. of Radiation Oncology, Erlangen (Germany)

    2015-01-10

    To assess the long-term results of protocol-based interstitial pulsed-dose-rate (PDR) brachytherapy as reirradiation combined with simultaneous chemotherapy and interstitial hyperthermia in selected patients with recurrent head and neck tumors. A total of 104 patients with biopsy-proven recurrent head and neck cancer were treated with interstitial PDR brachytherapy. Salvage surgery had also been undergone by 53/104 (51 %) patients (R1 or R2 resection in > 80 % of patients). Salvage brachytherapy alone was administered in 81 patients (78 %), with a median total dose of 56.7 Gy. Salvage brachytherapy in combination with external beam radiotherapy (EBRT) was performed in 23/104 patients (32 %), using a median total dose of D{sub REF} = 24 Gy. Simultaneously to PDR brachytherapy, concomitant chemotherapy was administered in 58/104 (55.8 %) patients. A single session of interstitial hyperthermia was also used to treat 33/104 (31.7 %) patients. The analysis was performed after a median follow-up of 60 months. Calculated according to Kaplan-Meier, local tumor control rates after 2, 5, and 10 years were 92.5, 82.4, and 58.9 %, respectively. Comparing results of salvage PDR brachytherapy with or without simultaneous chemotherapy, the 10-year local control rates were 76 vs. 39 % (p= 0014), respectively. No other patient- or treatment-related parameters had a significant influence on treatment results. Soft tissue necrosis or bone necrosis developed in 18/104 (17.3 %) and 11/104 (9.6 %) patients, respectively, but only 3 % of patients required surgical treatment. PDR interstitial brachytherapy with simultaneous chemotherapy is a very effective and, in experienced hands, also a safe treatment modality in selected patients with head and neck cancer in previously irradiated areas. (orig.) [German] Es erfolgte die Analyse der Langzeitergebnisse einer protokollbasierten interstitiellen Brachytherapie (Re-Bestrahlung) mit simultaner Chemotherapie und interstitieller Hyperthermie

  18. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives

    International Nuclear Information System (INIS)

    Castellani, C.M.; Battisti, P.; Tarroni, G.

    1998-01-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated [it

  19. Time-dose relationship in radiotherapy of gingival carcinoma. Therapeutic results

    International Nuclear Information System (INIS)

    Maciejewski, B.; Wojcieszek, Z.; Majewski, S.

    1982-01-01

    Therapeutic results were analysed in 30 patients with gingival carcinoma irradiated with 60 Co at the Institute of Oncology in Gliwice. Three-year asymptomatic survival rate was 26%. Administration of 1950 rets dose was associated with a high probability of cure and low risk of complications. Tumour diameter exceeding 3 cm, involvement of adjacent anatomical structures and metastases to cervical lymph nodes worsened considerably the prognosis. (author)

  20. Population dose due to natural radiation in Hong Kong

    International Nuclear Information System (INIS)

    Tso, M.Y.W.; Leung, J.K.C.

    2000-01-01

    In densely populated cities such as Hong Kong where people live and work in high-rise buildings that are all built with concrete, the indoor gamma dose rate and indoor radon concentration are not wide ranging. Indoor gamma dose rates (including cosmic rays) follow a normal distribution with an arithmetic mean of 0.22 ± 0.04 (micro)Gy h -1 , whereas indoor radon concentrations follow a log-normal distribution with geometric means of 48 ± 1 Bq m -3 and 90 ± 2 Bq m -3 for the two main categories of buildings: residential and non-residential. Since different occupations result in different occupancy in different categories of buildings, the annual total dose [indoor and outdoor radon effective dose + indoor and outdoor gamma absorbed dose (including cosmic ray)] to the population in Hong Kong was estimated based on the number of people for each occupation; the occupancy of each occupation; indoor radon concentration distribution and indoor gamma dose rate distribution for each category of buildings; outdoor radon concentration and gamma dose rate; and indoor and outdoor cosmic ray dose rates. The result shows that the annual doses for every occupation follow a log-normal distribution. This is expected since the total dose is dominated by radon effective dose, which has a log-normal distribution. The annual dose to the population of Hong Kong is characterized by a log-normal distribution with a geometric mean of 2.4 mSv and a geometric standard deviation of 1.3 mSv

  1. Radiation doses in Sweden as a result of the Chernobyl fallout

    Energy Technology Data Exchange (ETDEWEB)

    Wiktorson, Christor [Statens Stralskyddsinstitut, National Institute of Radiation Protection, Stockholm (Sweden)

    1986-07-01

    The radiation doses from the Chernobyl fallout originate mainly from two sources: External irradiation (ground radiation) and internal irradiation from radioactive materials accumulated in the human body via food. In addition there are an inhalation dose and a radiation dose from the radioactive cloud. The level of doses from the various sources is presented.

  2. Radiation doses in Sweden as a result of the Chernobyl fallout

    International Nuclear Information System (INIS)

    Wiktorson, Christor

    1986-01-01

    The radiation doses from the Chernobyl fallout originate mainly from two sources: External irradiation (ground radiation) and internal irradiation from radioactive materials accumulated in the human body via food. In addition there are an inhalation dose and a radiation dose from the radioactive cloud. The level of doses from the various sources is presented

  3. A real time dose monitoring and dose reconstruction tool for patient specific VMAT QA and delivery

    International Nuclear Information System (INIS)

    Tyagi, Neelam; Yang Kai; Gersten, David; Yan Di

    2012-01-01

    Purpose: To develop a real time dose monitoring and dose reconstruction tool to identify and quantify sources of errors during patient specific volumetric modulated arc therapy (VMAT) delivery and quality assurance. Methods: The authors develop a VMAT delivery monitor tool called linac data monitor that connects to the linac in clinical mode and records, displays, and compares real time machine parameters with the planned parameters. A new measure, called integral error, keeps a running total of leaf overshoot and undershoot errors in each leaf pair, multiplied by leaf width, and the amount of time during which the error exists in monitor unit delivery. Another tool reconstructs Pinnacle 3 ™ format delivered plan based on the saved machine logfile and recalculates actual delivered dose in patient anatomy. Delivery characteristics of various standard fractionation and stereotactic body radiation therapy (SBRT) VMAT plans delivered on Elekta Axesse and Synergy linacs were quantified. Results: The MLC and gantry errors for all the treatment sites were 0.00 ± 0.59 mm and 0.05 ± 0.31°, indicating a good MLC gain calibration. Standard fractionation plans had a larger gantry error than SBRT plans due to frequent dose rate changes. On average, the MLC errors were negligible but larger errors of up to 6 mm and 2.5° were seen when dose rate varied frequently. Large gantry errors occurred during the acceleration and deceleration process, and correlated well with MLC errors (r= 0.858, p= 0.0004). PTV mean, minimum, and maximum dose discrepancies were 0.87 ± 0.21%, 0.99 ± 0.59%, and 1.18 ± 0.52%, respectively. The organs at risk (OAR) doses were within 2.5%, except some OARs that showed up to 5.6% discrepancy in maximum dose. Real time displayed normalized total positive integral error (normalized to the total monitor units) correlated linearly with MLC (r= 0.9279, p < 0.001) and gantry errors (r= 0.742, p= 0.005). There is a strong correlation between total integral

  4. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, David J., E-mail: davideaton@nhs.net [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom); Warry, Alison J. [Department of Radiotherapy Physics, University College London Hospital, London (United Kingdom); Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H. [Department of Radiotherapy, Royal Free Hospital, London (United Kingdom)

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources.

  5. Benefits of online in vivo dosimetry for single-fraction total body irradiation

    International Nuclear Information System (INIS)

    Eaton, David J.; Warry, Alison J.; Trimble, Rachel E.; Vilarino-Varela, Maria J.; Collis, Christopher H.

    2014-01-01

    Use of a patient test dose before single-fraction total body irradiation (TBI) allows review of in vivo dosimetry and modification of the main treatment setup. However, use of computed tomography (CT) planning and online in vivo dosimetry may reduce the need for this additional step. Patients were treated using a supine CT-planned extended source-to-surface distance (SSD) technique with lead compensators and bolus. In vivo dosimetry was performed using thermoluminescent dosimeters (TLDs) and diodes at 10 representative anatomical locations, for both a 0.1-Gy test dose and the treatment dose. In total, 28 patients were treated between April 2007 and July 2013, with changes made in 10 cases (36%) following test dose results. Overall, 98.1% of measured in vivo treatment doses were within 10% of the prescribed dose, compared with 97.0% of test dose readings. Changes made following the test dose could have been applied during the single-fraction treatment itself, assuming that the dose was delivered in subportions and online in vivo dosimetry was available for all clinically important anatomical sites. This alleviates the need for a test dose, saving considerable time and resources

  6. Long-term brain structural magnetic resonance imaging and cognitive functioning in children treated for acute lymphoblastic leukemia with high-dose methotrexate chemotherapy alone or combined with CNS radiotherapy at reduced total dose to 12 Gy

    Energy Technology Data Exchange (ETDEWEB)

    Zajac-Spychala, Olga; Pilarczyk, Jakub; Derwich, Katarzyna; Wachowiak, Jacek [Poznan University of Medical Sciences, Department of Pediatric Oncology, Hematology and Transplantology, Poznan (Poland); Pawlak, Mikolaj A. [Poznan University of Medical Sciences, Department of Neurology and Cerebrovascular Disorders, Poznan (Poland); Karmelita-Katulska, Katarzyna [Poznan University of Medical Sciences, Department of Neuroradiology, Poznan (Poland)

    2017-02-15

    The aim of this study was to assess the long-term side effects of central nervous system prophylaxis (high-dose chemotherapy alone vs chemotherapy and CNS radiotherapy) according to the ALL IC-BFM 2002. Thirty-tree children aged 6.7-19.9 years have been studied. The control group consisted of 12 children newly diagnosed with acute lymphoblastic leukemia. We assessed subcortical gray matter volume using automatic MRI segmentation and cognitive performance to identify differences between two therapeutic schemes and patients prior to treatment. Patients treated with chemotherapy and CNS radiotherapy had smaller hippocampi than two other subgroups and lower IQ score than patients treated with chemotherapy alone. Both treated groups, whether with chemotherapy only or in combination with CNS radiotherapy, had significantly lower volumes of caudate nucleus and performed significantly worse on measures of verbal fluency in comparison with patients prior to treatment. There were no differences in the mean volumes of total white matter, total gray matter, thalamus, putamen, and amygdala between the studied groups. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment was observed, especially in children who received chemotherapy in combination with reduced dose CNS radiotherapy. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment were observed, especially in children who received chemotherapy in combination with CNS radiotherapy. (orig.)

  7. Long-term brain structural magnetic resonance imaging and cognitive functioning in children treated for acute lymphoblastic leukemia with high-dose methotrexate chemotherapy alone or combined with CNS radiotherapy at reduced total dose to 12 Gy

    International Nuclear Information System (INIS)

    Zajac-Spychala, Olga; Pilarczyk, Jakub; Derwich, Katarzyna; Wachowiak, Jacek; Pawlak, Mikolaj A.; Karmelita-Katulska, Katarzyna

    2017-01-01

    The aim of this study was to assess the long-term side effects of central nervous system prophylaxis (high-dose chemotherapy alone vs chemotherapy and CNS radiotherapy) according to the ALL IC-BFM 2002. Thirty-tree children aged 6.7-19.9 years have been studied. The control group consisted of 12 children newly diagnosed with acute lymphoblastic leukemia. We assessed subcortical gray matter volume using automatic MRI segmentation and cognitive performance to identify differences between two therapeutic schemes and patients prior to treatment. Patients treated with chemotherapy and CNS radiotherapy had smaller hippocampi than two other subgroups and lower IQ score than patients treated with chemotherapy alone. Both treated groups, whether with chemotherapy only or in combination with CNS radiotherapy, had significantly lower volumes of caudate nucleus and performed significantly worse on measures of verbal fluency in comparison with patients prior to treatment. There were no differences in the mean volumes of total white matter, total gray matter, thalamus, putamen, and amygdala between the studied groups. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment was observed, especially in children who received chemotherapy in combination with reduced dose CNS radiotherapy. In all children treated according to the ALL IC-BFM 2002 with high-dose chemotherapy, both decreased volume of selected subcortical structures and cognitive impairment were observed, especially in children who received chemotherapy in combination with CNS radiotherapy. (orig.)

  8. Radiation doses in Sweden as a result of the Chernobyl fallout

    International Nuclear Information System (INIS)

    1987-04-01

    The dose to people living in Sweden originates mainly from external radiation from the ground and from internal radiation from radioactive materials accumulated in the body via foodstuff. In addition there are an inhalation dose and a dose from the radioactive cloud. The collective dose in nSv for the 1st year and for 50 years is evaluated. (orig./HP)

  9. Preliminary results on food consumption rates for off-site dose calculation of nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Gab Bock; Chung, Yang Geun; Bang, Sun Young; Kang, Duk Won

    2005-01-01

    The Internal dose by food consumption mostly account for radiological dose of public around nuclear power plants(NPP). But, food consumption rate applied to off-site dose calculation in Korea which is the result of field investigation around Kori NPP by the KAERI in 1988. is not reflected of the latest dietary characteristics. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. To update the food consumption rates of the maximum individual, the analysis of the national food investigation results and field surveys around nuclear power plant sites have been carried out

  10. The evolution of doses in the IEA-R1 reactor environment and tendencies based on the current results

    International Nuclear Information System (INIS)

    Toyoda, Eduardo Yoshio

    2016-01-01

    The IPEN / CNEN-SP have a Nuclear Research Reactor-NRR named IEA-R1, in operation from 1957. It is an open swimming pool reactor using light water as shielding, moderator and as cooling, the volume of this pool is 273m 3 .Until 1995 the reactor operated daily at a power of 2,0 MW. From June of that year, after a few safety modifications the reactor began operating in continuous way from Monday to Wednesday without shutdown totalizing 64 hours per week and the power was increased to 4,5MW also. Because of these changes, continuous operation and increased power, workers' doses would tend to increase. In the past several studies were conducted seeking ways to reduce the workers' doses. A study was made on the possibility to introduce a shielding at the top of the reactor core with a hot water layer. Studies have shown that a major limitation for operating a reactor at high power comes from the gamma radiation emitted by the sodium-24. Other elements such as magnesium-27, aluminum-28, Argon-51, contribute considerably to the water activity of the pool. The introduction of a hot water layer on the swimming pool would form a layer of surface, stable and free of radioactive elements with a 1.5m to 2m thickness creates a shielding to radiation from radioactive elements dissolved in water. Optimization studies proved that the installation of the hot layer was not necessary for the regime and the current power reactor operation, because other procedures adopted were more effective. From this decision the Radiological Protection Reactor Team, set up a dose assessment program to ensure them remained in low values based on principles established in national and international standards. The purpose of this paper is to analyze the individual doses of OEI (Occupationally Exposed Individual), which will be checked increasing doses resulting from recent changes in reactor operation regime and suggested viable safety and protection options, in the first instance to reducing

  11. Infinite slab-shield dose calculations

    International Nuclear Information System (INIS)

    Russell, G.J.

    1989-01-01

    I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab

  12. Total body irradiation for children with malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sanuki, Eiichi; Maeno, Toshio; Kamata, Rikisaburo; Tanaka, Yoshiaki; Mugishima, Hideo [Nihon Univ., Tokyo (Japan). School of Medicine

    1995-12-01

    Total body irradiation combined with high dose chemotherapy has been performed just before bone marrow transplantation in 35 children with advanced malignancies, with the object of achieving successful transplantation and improving the prognosis. Simulation was performed as follows: back scatter, flatness, dose accumulation using randophantom and dose distribution using a thermo-luminescence dosimeter and linac-graphy. The standard error of dose distribution was within 10%. In neuroblastoma, of which there were 14 cases in stage IV and one case in stage III, the 5-year survival rate was 55%. In leukemia, of which all cases were in the high-risk group (7 cases of acute lymphoblastic leukemia and 2 of acute myeloblastic leukemia) the 5-year survival rate was 55%. The 5 cases having first remission survived disease-free while the 4 cases having non-first remission died. In malignant lymphoma (6 cases in stage IV and one case in stage III, with bulky mass) the 5-year survival rate was 67%. Four cases with other diagnoses (severe aplastic anemia, and others) all survived. As yet no side effects resulting from total body irradiation have been recognized in our cases, but a longer follow-up period is necessary to observe possible late side effects. (author).

  13. Monitoring and radiation dose estimation for internal contamination of occupational workers

    Energy Technology Data Exchange (ETDEWEB)

    Kol, R; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    The assessment of interval radiation doses due to intake of radionuclides differs totally from external dosimetry. External dosimetry is relatively straight forward: Workers are equipped with appropriate dosimeters that give the dose upon direct reading. Internal dosimetry is actually an assessment of the dose based on results of personnel and environmental monitoring (authors).

  14. Dose optimization with first-order total-variation minimization for dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hojin; Li Ruijiang; Lee, Rena; Goldstein, Thomas; Boyd, Stephen; Candes, Emmanuel; Xing Lei [Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States) and Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Department of Radiation Oncology, Ehwa University, Seoul 158-710 (Korea, Republic of); Department of Electrical Engineering, Stanford University, Stanford, California 94305-9505 (United States); Department of Statistics, Stanford University, Stanford, California 94305-4065 (United States); Department of Radiation Oncology, Stanford University, Stanford, California 94305-5304 (United States)

    2012-07-15

    Purpose: A new treatment scheme coined as dense angularly sampled and sparse intensity modulated radiation therapy (DASSIM-RT) has recently been proposed to bridge the gap between IMRT and VMAT. By increasing the angular sampling of radiation beams while eliminating dispensable segments of the incident fields, DASSIM-RT is capable of providing improved conformity in dose distributions while maintaining high delivery efficiency. The fact that DASSIM-RT utilizes a large number of incident beams represents a major computational challenge for the clinical applications of this powerful treatment scheme. The purpose of this work is to provide a practical solution to the DASSIM-RT inverse planning problem. Methods: The inverse planning problem is formulated as a fluence-map optimization problem with total-variation (TV) minimization. A newly released L1-solver, template for first-order conic solver (TFOCS), was adopted in this work. TFOCS achieves faster convergence with less memory usage as compared with conventional quadratic programming (QP) for the TV form through the effective use of conic forms, dual-variable updates, and optimal first-order approaches. As such, it is tailored to specifically address the computational challenges of large-scale optimization in DASSIM-RT inverse planning. Two clinical cases (a prostate and a head and neck case) are used to evaluate the effectiveness and efficiency of the proposed planning technique. DASSIM-RT plans with 15 and 30 beams are compared with conventional IMRT plans with 7 beams in terms of plan quality and delivery efficiency, which are quantified by conformation number (CN), the total number of segments and modulation index, respectively. For optimization efficiency, the QP-based approach was compared with the proposed algorithm for the DASSIM-RT plans with 15 beams for both cases. Results: Plan quality improves with an increasing number of incident beams, while the total number of segments is maintained to be about the

  15. A comparison of the effects of 2 doses of soy protein or casein on serum lipids, serum lipoproteins, and plasma total homocysteine in hypercholesterolemic subjects.

    Science.gov (United States)

    Tonstad, Serena; Smerud, Knut; Høie, Lars

    2002-07-01

    Studies have shown that soy protein reduces some atherogenic lipid and lipoprotein concentrations, although lipoprotein(a) concentrations may be increased. The dose response of soy protein has not been established; neither has its effect on plasma total homocysteine. Our objective was to evaluate the effect of 2 doses of soy protein on lipid, lipoprotein, and homocysteine concentrations. Four to 24 wk after being instructed to consume a lipid-lowering diet, 130 men and women with LDL-cholesterol concentrations > or = 4 mmol/L were studied during a parallel group trial in which 4 interventions were assigned randomly. Thirty grams isolated soy protein (ISP) and 10 g cotyledon fiber or 50 g ISP and 16.6 g cotyledon fiber or equivalent doses of casein and cellulose were consumed daily as a beverage for 16 wk. When the 2 groups who consumed ISP were compared with the 2 groups who consumed casein, the differences in the net changes from baseline to week 16 in the concentrations of LDL cholesterol and plasma total homocysteine were -0.26 mmol/L (95% CI: -0.43, -0.09 mmol/L; P = 0.01) and -0.8 micromol/L (-1.4, -0.2 micromol/L; P = 0.005), respectively. The effect of the ISP dose was not significant. There were no significant differences between the 2 ISP and the 2 casein groups in changes in lipoprotein(a), HDL-cholesterol, or triacylglycerol concentrations. Adding 30-50 g soy protein/d to a lipid-lowering diet significantly reduced LDL-cholesterol concentrations without increasing lipoprotein(a) concentrations. Plasma total homocysteine concentrations also decreased, suggesting a novel, possibly antiatherosclerotic effect.

  16. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  17. Effective dose to patients from thoracic spine examinations with tomosynthesis

    International Nuclear Information System (INIS)

    Svalkvist, Angelica; Baath, Magnus; Soederman, Christina

    2016-01-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm -2 was obtained. (authors)

  18. Effective dose and cancer risk in PET/CT exams; Dose efetiva e risco de cancer em exames de PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Gabriella M.; Sa, Lidia Vasconcellos de, E-mail: montezano@ird.gov.br, E-mail: Iidia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    Due to the use of radiopharmaceutical positron-emitting in PET exam and realization of tomography by x-ray transmission in CT examination, an increase of dose with hybrid PET/CT technology is expected. However, differences of doses have been reported in many countries for the same type of procedure. It is expected that the dose is an influent parameter to standardize the protocols of PET/CT. This study aimed to estimate the effective doses and absorbed in 65 patients submitted to oncological Protocol in a nuclear medicine clinic in Rio de Janeiro, considering the risk of induction of cancer from the scan. The CT exam-related doses were estimated with a simulator of PMMA and simulated on the lmPACT resistance, which for program effective dose, were considered the weight factors of the lCRP 103. The PET exam doses were estimated by multiplying the activity administered to the patient with the ICRP dose 80 factors. The radiological risk for cancer incidence were estimated according to the ICRP 103. The results showed that the effective dose from CT exam is responsible for 70% of the effective total in a PET/CT scan. values of effective dose for the PET/CT exam reached average values of up to 25 mSv leading to a risk of 2, 57 x 10{sup -4}. Considering that in staging of oncological diseases at least four tests are performed annually, the total risk comes to 1,03x 10{sup -3}.

  19. Estimation of thyroid doses received by the population of Belarus as a result of the Chernobyl accident

    International Nuclear Information System (INIS)

    Gavrilin, Yu.; Khrouch, V.; Shinkarev, S.; Drozdovitch, V.; Minenko, V.; Shemyakina, E.; Bouville, A.; Anspaugh, L.

    1996-01-01

    Within weeks of the Chernobyl accident, about 300000 measurements of human thyroidal 131 I content were conducted in the more contaminated territories of the Republic of Belarus. Results of these and other measurements form the basis of thyroid-dose reconstruction for residents of Belarus. Preliminary estimates of thyroid doses have been divided into three classes. Class 1 ('measured' doses). Individual doses are estimated directly from the measured thyroidal 131 I content of the person considered, plus information on life style and dietary habits. Such estimates are available for about 130000 individuals from the contaminated areas of Gomel and Mogilev Region and Minsk city. Class 2 ('passport' doses). For every settlement with a sufficient number of residents with 'measured' doses, individual thyroid-dose distributions are determined for several age groups and levels of milk consumption. This action has been called the 'passportization' of the settlement. A population of about 2.7 million people resides in the 'passportized' settlements. Class 3 ('inferred' doses). For any settlement where the number of residents with 'measured' doses is small or equal to zero, individual thyroid doses are derived from the relationship obtained between the mean adult-thyroid dose and the deposition density of 131 I or 137 Cs in settlements with 'passport' doses presenting characteristics similar to those of the settlement considered. This method can be applied to the remainder of the population (about 7.3 million people). An approximate estimate of the collective thyroid dose for the residents of Belarus is presented. Illustrative results of individual thyroid dose and associated uncertainty are discussed for rural settlements and urban areas

  20. Acute tolerance of hyperfractionated accelerated total body irradiation

    International Nuclear Information System (INIS)

    Latz, D.; Schraube, P.; Wannenmacher, M.

    1996-01-01

    Background: Acute side effects of total body irradiation lead to intense molestations of the patients. Therefore, it is desirable to take measures to reduce these side effects. In a retrospective study the frequency on acute side effects of a hyperfractionated accelerated total body irradiation was assessed and compared to frequencies of other exposure schedules published in the literature. Additionally the influence of ondansetron on the frequency of nausea and vormiting was investigated. Patients and Method: From 1989 to 1992, 76 patients (47 male, 29 female; median age 38 years) underwent total body irradiation before autologeous bone marrow transplantation. They received 3 daily doses of 1.20 Gy each every 4 h on 4 successive days to a total dose of 14,40 Gy. Thirty-nine patients received 3x8 mg (daily, intravenous or per os) ondansetron during the whole course of irradiation. Results: The most relevant side effects were nausea and vomiting. Patients, who did not receive ondansetron (n=37) showed a nausea and emesis rate of 73%. With ondansetron (n=39) nausea and emesis were reduced to 38%. Also the grade of severity of these side effects was reduced. Conclusions: Ondansetron proved to be an effective medicament for relieving nausea and vormiting during total body irradiation. The results obtained are in concordance with those published in the literature. (orig.) [de

  1. Evaluation and comparison of gamma- and electron beam irradiation effects on total and free gossypol of cottonseed meal

    International Nuclear Information System (INIS)

    Shawrang, P.; Mansouri, M.H.; Sadeghi, A.A.; Ziaie, F.

    2011-01-01

    Impact of gamma- and electron beam irradiation on total and free gossypol content of cottonseed meal was assessed by exposing them to doses of 10, 15, 20, 25 and 30 kGy. Gamma rays and electron beam showed the same effects with significant dose-dependent decrease in total and free gossypol content. Based on these results, ionizing irradiation at doses of 25 kGy and above could completely remove free gossypol and bring down total gossypol content to permissible level in poultry feed.

  2. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  3. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    Energy Technology Data Exchange (ETDEWEB)

    Kohlbrenner, R; Kolli, KP; Taylor, A; Kohi, M; Fidelman, N; LaBerge, J; Kerlan, R; Gould, R [University of California, San Francisco, San Francisco, CA (United States)

    2014-06-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav

  4. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    International Nuclear Information System (INIS)

    Kohlbrenner, R; Kolli, KP; Taylor, A; Kohi, M; Fidelman, N; LaBerge, J; Kerlan, R; Gould, R

    2014-01-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav

  5. Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results

    International Nuclear Information System (INIS)

    Bodelle, B.; Wichmann, J.L.; Klotz, N.; Lehnert, T.; Vogl, T.J.; Luboldt, W.; Schulz, B.

    2015-01-01

    Aim: To evaluate the diagnostic image quality and radiation dose of low-dose 70 kV computed tomography (CT) of the paranasal sinus in comparison to 100 and 120 kV CT. Materials and methods: CT of the paranasal sinus was performed in 127 patients divided into three groups using different tube voltages and currents (70 kV/75 mAs, ultra-low dose protocol, n = 44; 100 kV/40 mAs, standard low-dose protocol, n = 42; 120 kV/40 mAs, standard protocol, n = 41). CT dose index (CTDIvol), dose–length product (DLP), attenuation, image noise and signal-to-noise ratio (SNR) were compared between the groups using Wilcoxon–Mann–Whitney U-test. Subjective diagnostic image quality was compared by using a five-point scale (1 = non-diagnostic, 5 = excellent, read by two readers in consensus) and Cohen's weighted kappa analysis for interobserver agreement. Results: Radiation dose was significantly lower with 70 kV acquisition than 100 and 120 kV (DLP: 31 versus 52 versus 82 mGy·cm; CTDI 2.33 versus 3.95 versus 6.31 mGy, all p < 0.05). Mean SNR (70 kV: 0.37; 100 kV: 0.21; 120 kV: 0.13; p < 0.05) and organ attenuation increased significantly with lower voltages. All examinations showed diagnostic image quality. Subjective diagnostic image quality was higher with standard protocols than the 70 kV protocol (120 kV: 5.0; 100 kV: 4.5; 70 kV: 3.5, p < 0.05) without significant differences with substantial interobserver agreement (κ > 0.59). Conclusion: The ultra-low dose (70 kV) CT imaging of the paranasal sinus allowed for significant dose reduction by 61% and an increased attenuation of organ structures in comparison to standard acquisition while maintaining diagnostic image quality with a slight reduction in subjective image quality. -- Highlights: •Image quality and radiation dose of 70 kV ultra-low dose CT of the paranasal sinus. •70 kV ultra-low dose CT of the paranasal sinus allows for dose reduction by 61%. •70 kV CT of the

  6. Clinical result of high-dose rate intraluminal brachytherapy for esophageal carcinoma with a remote afterloading system

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Toshifumi; Tada, Takuhito; Tanaka, Masahiro; Tsumura, Masashi; Onoyama, Yasuto

    1992-01-01

    During the period from 1977 through 1987, 105 patients with esophageal carcinoma were radically treated by radiotherapy. Forty-six patients receiving therapy before August 1982 were all treated by external beam therapy alone (Group 1). Since September 1982, 26 patients were treated by external beam therapy alone (Group 2) and 33 patients were treated by high-dose-rate intraluminal brachytherapy with a remote afterloading system combined with external beam therapy (Group 3). Dose of external beam therapy for Group 1, Group 2 and Group 3 patients were 66.7 Gy, 68.7 Gy and 55.9 Gy on the average. The intraluminal brachytherapy was performed with a total dose of 12 Gy consisting of 3 Gy twice a week. Ten of 72 patients (14%) treated by external beam therapy alone achieved complete response, whereas 14 of 33 patients (42%) treated by high-dose-rate intraluminal brachytherapy combined with external beam therapy had complete response. One-, and 3-year survival rates were 36% and 10% in the Group 1, 32% and 12% in the Group 2 and 56% and 36% in the Group 3. For Group 3, good survival rate was obtained in tumorous type and serrated type. Patients with tumor of less than 5 cm in Group 3 had good survival. The data suggest that the high-dose-rate intraluminal bracytherapy prescribed as a boost therapy following external beam therapy is an effective therapy modality for esophageal carcinoma which is of non-circumferential tumor or less than 5 cm. (author)

  7. Optimum curative dose and the results of radiotherapy of the lower lip, larynx and cervix uteri neoplasms

    International Nuclear Information System (INIS)

    Kholin, V.V.; Libson, I.L.; Bartova, V.F.; Lubenets, Eh.N.

    1982-01-01

    An analysis of the results of radiotherapy of 951 patients with cancer of the lower lip, larynx and cervix uteri on the basis of the concept of a single optimum curative dose (OCD 1 ) is presented. The best long-term results (in good health for 3 years and more) were obtained for T 1 Stage with summary focal doses that were equivalent to OCD 1 : 98% for the lowel lip, 95% for the larynx, and 93.9% for cervix uteri. It has been shown that OCD 1 estimated for identical tumor volumes (1 cm 3 ) taking account of the character of fractionation and dose rate for all known sites is practically the same - about 24 Gy. It has been demonstrated that to reach a maximum effect with the growth of tumor volume, the summary curative dose should be increased; however, of common knowledge is that under the conditions of γ-beam therapy by simple fractionation the summary focal doses cannot exceed 60-80 Gy. The above doses can result in a radical effect in tumor volumes not more than 5-6 cm 3 . This tumor volume is regarded as a maximum one for cure of malignant epithelial tumors. In large volume tumors one should rely upon palliative radiotherapeutic results [ru

  8. Analgesic and sedative effects of perioperative gabapentin in total knee arthroplasty A randomized, double-blind, placebo-controlled, dose-finding study

    DEFF Research Database (Denmark)

    Lunn, Troels Haxholdt; Husted, Henrik; Laursen, Mogens Berg

    2015-01-01

    (1:1:1) to either gabapentin 1300 mg/d (group A), gabapentin 900 mg/d (group B), or placebo (group C) daily from 2 hours preoperatively to postoperative day 6 in addition to a standardized multimodal analgesic regime. The primary outcome was pain upon ambulation 24 hours after surgery......Gabapentin has shown acute postoperative analgesic effects, but the optimal dose and procedure-specific benefits vs harm have not been clarified. In this randomized, double-blind, placebo-controlled dose-finding study, 300 opioid-naive patients scheduled for total knee arthroplasty were randomized......, and the secondary outcome was sedation 6 hours after surgery. Other outcomes were overall pain during well-defined mobilizations and at rest and sedation during the first 48 hours and from days 2-6, morphine use, anxiety, depression, sleep quality, and nausea, vomiting, dizziness, concentration difficulty, headache...

  9. First results of radioiodine therapy of multifocal and disseminated functional thyroid autonomy using a TcTUs-adapted dose concept

    International Nuclear Information System (INIS)

    Oexle, C.; Reinhardt, M.; Moser, E.

    1998-01-01

    Aim: The presented study examines prospectively the efficiency of a dose concept for radioiodine therapy (RIT) adapted to the pretherapeutic 99m Tc-pertechnetate thyroid uptake under suppression (TcTU s ) in patients with multifocal (MFA) and disseminated (DISA) autonomy. This concept considers the total thyroid as target volume and uses target doses from 150 Gy to 300 Gy according to the TcTU s , which is as a measure for the 'autonomous volume' of the thyroid. Methods: The data of 75 patients (54 female, 21 male; age 71±9 years) with MFA or DISA were evaluated. RIT was performed on patients presenting with normal values for free triiodothyronine and thyroxine and endogenous suppression of the basal thyrotropin (TSH). The following target doses were used: For a TcTU s of 1,5-2,5% 150 Gy, for 2,51-3,5% 200 Gy, for 3,51-4,5% 250 Gy, and for >4,5% 300 Gy. The radiation dose to be administered was calculated using a modified Marinelli formula. The therapy was considered as successful when the basal TSH was above 0,5 mU/l and autonomous areas had disapeared in thyroid scintigraphy or the TcTU was below 1,5%, respectively. The average follow-up period was 8±4 months. Results: The success rates average to 92%. Only in one case a subsequent subclinical hypothyroidism and in a further case an immunogenic hyperthyroidism occured. Conclusion: The presented data indicate, that even patients with a marked autonomy (TcTU s >3,5%) can thus expected to be cured by of a onetime therapy with success rate of over 90% using the presented dose concept. The rate of early hypothyroidism can alltogether be estimated as very low. (orig.) [de

  10. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  11. Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan

    International Nuclear Information System (INIS)

    Maruyama, Takashi; Nishizawa, Kanae; Kumamoto, Yoshikazu; Iwai, Kazuo; Mase, Naomichi.

    1993-01-01

    Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord length technique and with data from ICRP publications. The annual collective effective dose equivalent were estimated to be about 21.94 person·Sv for medical workers, 7.73 person·Sv for industrial workers, 0.75 person·Sv for research and educational workers, 2.48 person·Sv for atomic energy industry and 84.4 person ·Sv for workers in nuclear power station. The population doses were calculated to be about 1.07 Sv for genetically significant dose, 0.89 Sv for leukemia significant dose and 0.42 Sv for malignant significant dose. The population risks were estimated using these population doses. (author)

  12. Absorbed bone marrow dose in certain dental radiographic techniques

    International Nuclear Information System (INIS)

    White, S.C.; Rose, T.C.

    1979-01-01

    The absorbed dose of radiation in the bone marrow of the region of the head and neck was measured during intraoral, panoramic, and cephalometric radiography. Panoramic radiography results in a dose a fifth or less than that from an intraoral survey. The use of rectangular collimation reduces the bone marrow absorbed dose from an intraoral survey by about 60%. Comparison of the doses from dental radiography with natural environmental radiation shows that an intraoral set of films results in the same total dose to the bone marrow as 65 days of background exposure. The use of rectangular collimation reduces this value to 25 days. Panoramic radiography results in significantly less irradiation, as it reduces the value to 14 days or fewer. Dental radiography thus involves exposures in the range of variation of natural environmental background values

  13. Total lymphoid irradiation

    International Nuclear Information System (INIS)

    Sutherland, D.E.; Ferguson, R.M.; Simmons, R.L.; Kim, T.H.; Slavin, S.; Najarian, J.S.

    1983-01-01

    Total lymphoid irradiation by itself can produce sufficient immunosuppression to prolong the survival of a variety of organ allografts in experimental animals. The degree of prolongation is dose-dependent and is limited by the toxicity that occurs with higher doses. Total lymphoid irradiation is more effective before transplantation than after, but when used after transplantation can be combined with pharmacologic immunosuppression to achieve a positive effect. In some animal models, total lymphoid irradiation induces an environment in which fully allogeneic bone marrow will engraft and induce permanent chimerism in the recipients who are then tolerant to organ allografts from the donor strain. If total lymphoid irradiation is ever to have clinical applicability on a large scale, it would seem that it would have to be under circumstances in which tolerance can be induced. However, in some animal models graft-versus-host disease occurs following bone marrow transplantation, and methods to obviate its occurrence probably will be needed if this approach is to be applied clinically. In recent years, patient and graft survival rates in renal allograft recipients treated with conventional immunosuppression have improved considerably, and thus the impetus to utilize total lymphoid irradiation for its immunosuppressive effect alone is less compelling. The future of total lymphoid irradiation probably lies in devising protocols in which maintenance immunosuppression can be eliminated, or nearly eliminated, altogether. Such protocols are effective in rodents. Whether they can be applied to clinical transplantation remains to be seen

  14. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  15. Long-Term Results After High-Dose Radiotherapy and Adjuvant Hormones in Prostate Cancer: How Curable Is High-Risk Disease?

    Energy Technology Data Exchange (ETDEWEB)

    Zapatero, Almudena, E-mail: azapatero.hlpr@salud.madrid.org [Department of Radiation Oncology, Hospital Universitario de la Princesa, Madrid (Spain); Garcia-Vicente, Feliciano [Department of Medical Physics, Hospital Universitario de la Princesa, Madrid (Spain); Martin de Vidales, Carmen; Cruz Conde, Alfonso; Ibanez, Yamile [Department of Radiation Oncology, Hospital Universitario de la Princesa, Madrid (Spain); Fernandez, Inmaculada; Rabadan, Mariano [Department of Urology, Hospital Universitario de la Princesa, Madrid (Spain)

    2011-12-01

    Purpose: To analyze long-term outcome and prognostic factors for high-risk prostate cancer defined by National Comprehensive Cancer Network criteria treated with high-dose radiotherapy and androgen deprivation in a single institution. Methods and Materials: A total of 306 patients treated between 1995 and 2007 in a radiation dose-escalation program fulfilled the National Comprehensive Cancer Network high-risk criteria. Median International Commission on Radiation Units and Measurements radiation dose was 78 Gy (range, 66.0-84.1 Gy). Long-term androgen deprivation (LTAD) was administered in 231 patients, short-term androgen deprivation (STAD) in 59 patients, and no hormones in 16 patients. The Phoenix (nadir plus 2 ng/mL) consensus definition was used for biochemical control. Multivariate analysis was performed to determine the independent prognostic impact of clinical and treatment factors. Median follow-up time was 64 months (range, 24-171 months). Results: The actuarial overall survival at 5 and 10 years was 95.7% and 89.8%, respectively, and the corresponding biochemical disease-free survival (bDFS) was 89.5% and 67.2%, respectively. Fourteen patients (4.6%) developed distant metastasis. Multivariate analysis showed that Gleason score >7 (p = 0.001), pretreatment prostate-specific antigen (PSA) level >20 ng/mL (p = 0.037), higher radiation dose (p = 0.005), and the use of adjuvant LTAD vs. STAD (p = 0.011) were independent prognostic factors affecting bDFS in high-risk disease. The 5-year bDFS for patients treated with LTAD plus radiotherapy dose >78 Gy was 97%. Conclusions: For high-risk patients the present series showed that the use of LTAD in conjunction with higher doses (>78 Gy) of radiotherapy was associated with improved biochemical tumor control. We observed that the presence of Gleason sum >7 and pretreatment PSA level >20 ng/mL in the same patient represents a 6.8 times higher risk of PSA failure. These men could be considered for clinical trials with

  16. Serum total homocystein, folate and vitamin B12 levels and their correlation with antipsychotic drug doses in adult male patients with chronic schizophrenia.

    Science.gov (United States)

    Eren, Esin; Yeğin, Ayşenur; Yilmaz, Necat; Herken, Hasan

    2010-01-01

    Elevated blood levels of homocysteine (hCY) have been associated with schizophrenic male patients. However, controversy remains regarding the association between lowered plasma folate and vitamin B12, hyperhomocysteinemia, and schizophrenia. Sixty-six (66) male patients with chronic schizophrenia were investigated to test the hypotheses that alterations in Hcy, folate, and vitamin B12 levels might be related to the antipsychotic drug doses used in treatment. Serum total homocysteine, folic acid, and vitamin B12 levels were determined by chemiluminescence methods in both patients and control subjects. The patients were grouped according to the antipsychotic drug doses used in their treatment. Patients had higher homocysteine levels but they did not differ from controls in terms of folate and vitamin B12 levels. On the other hand, only folate levels were negatively correlated in the patient group treated with higher therapeutic doses of chlorpromazine equivalents (> 400 mg/day) compared to the patient group with lower doses (< 400 mg/day). Our findings show that higher typical antipsychotic drugs may play a role as modifiying factor for folate metabolism in chronic schizoprenic male patients.

  17. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Kondziolka, D; Flickinger, J; Lunsford, L D; Young, R; Vermeulen, S; Duma, C; Jacques, D B; Rand, R; Regis, J; Peragut, J C; Epstein, M H; Lindquist, C

    1995-07-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of {>=} 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  18. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    International Nuclear Information System (INIS)

    Kondziolka, D.; Flickinger, J.; Lunsford, L.D.; Young, R.; Vermeulen, S.; Duma, C.; Jacques, D.B.; Rand, R.; Regis, J.; Peragut, J.C.; Epstein, M.H.; Lindquist, C.

    1995-01-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of ≥ 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  19. Sexual Function After Three-Dimensional Conformal Radiotherapy for Prostate Cancer: Results From a Dose-Escalation Trial

    International Nuclear Information System (INIS)

    Wielen, Gerard J. van der; Putten, Wim van; Incrocci, Luca

    2007-01-01

    Purpose: The purpose of this study is to provide information about sexual function (SF) after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer while taking important factors into account that influence SF. Methods and Materials: Between June 1997 and February 2003, a total of 268 patients from a randomized dose-escalation trial comparing 68 Gy and 78 Gy agreed to participate in an additional part of the trial that evaluated SF. Results: At baseline 28% of patients had erectile dysfunction (ED). After 1 year, 27% of the pretreatment potent patients had developed ED. After 2 years this percentage had increased to 36%. After 3 years it almost stabilized at 38%. Satisfaction with sexual life was significantly correlated with ED. After 2 years one third of the pre-treatment potent patients still had considerable to very much sexual desire and found sex (very) important. No significant differences were found between the two dose-arms. Potency aids were used on a regular base by 14% of the patients. Conclusion: By taking adjuvant hormonal therapy (HT), HT during follow-up and potency aids into account, we found a lower percentage of ED after 3D-CRT than reported in previous prospective studies. A large group of patients still had sexual desire, considered sex important and 14% used potency aids after 3D-CRT

  20. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    International Nuclear Information System (INIS)

    Rahimi, Asal; Thomas, Kimberly; Spangler, Ann; Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha; Seiler, Stephen; Albuquerque, Kevin; Stevenson, Stella; Goudreau, Sally; Garwood, Dan; Haley, Barbara; Euhus, David; Heinzerling, John; Ding, Chuxiong; Gao, Ang; Ahn, Chul; Timmerman, Robert

    2017-01-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  1. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Asal, E-mail: asal.rahimi@utsouthwestern.edu [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Thomas, Kimberly; Spangler, Ann [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha [Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Seiler, Stephen [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Albuquerque, Kevin; Stevenson, Stella [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Goudreau, Sally [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Garwood, Dan [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Haley, Barbara [Department of Medical Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Euhus, David [Department of Surgery, Johns Hopkins University, Baltimore, Maryland (United States); Heinzerling, John [Department of Radiation Oncology, Levine Cancer Institute, Charlotte, North Carolina (United States); Ding, Chuxiong [University of Texas Southwestern Medical Center, Dallas, Texas (United States); Gao, Ang; Ahn, Chul [Department of Statistics, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Timmerman, Robert [University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2017-05-01

    Purpose: To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Methods and Materials: Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. Results: In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Conclusion: Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for

  2. High-dose preoperative radiation for cancer of the rectum: Impact of radiation dose on patterns of failure and survival

    International Nuclear Information System (INIS)

    Ahmad, N.R.; Mohiuddin, M.; Marks, G.

    1993-01-01

    A variety of dose-time schedules are currently used for preoperative radiation therapy of rectal cancer. An analysis of patients treated with high-dose preoperative radiation therapy was undertaken to determine the influence of radiation dose on the patterns of failure, survival, and complications. Two hundred seventy-five patients with localized rectal cancer were treated with high-dose preoperative radiation therapy. One hundred fifty-six patients received 45 Gy (low-dose group). Since 1985, 119 patients with clinically unfavorable cancers were given a higher dose, 55 Gy using a shrinking field technique (high-dose group). All patients underwent curative resection. Median follow-up was 66 months in the low-dose group and 28 months in the high-dose group. Patterns of failure, survival, and complications were analyzed as a function of radiation dose. Fourteen percent of the total group developed a local recurrence; 20% in the low-dose group as compared with 6% in the high-dose group. The actuarial local recurrence rate at 5 years was 20% for the low-dose group and 8% for the high-dose group, and approached statistical significance with p = .057. For tethered/fixed tumors the actuarial local recurrence rates at 5 years were 28% and 9%, respectively, with p = .05. Similarly, for low-lying tumors (less than 6 cm from the anorectal junction) the rates were 24% and 9%, respectively, with p = .04. The actuarial rate of distant metastasis was 28% in the low-dose group and 20% in the high-dose group and was not significantly different. Overall actuarial 5-year survival for the total group of patients was 66%. No significant difference in survival was observed between the two groups, despite the higher proportion of unfavorable cancers in the high-dose group. The incidence of complications was 2%, equally distributed between the two groups. High-dose preoperative radiation therapy for rectal cancer results in excellent local control rates. 27 refs., 2 figs., 8 tabs

  3. Pulsed dose rate and fractionated high dose rate brachytherapy: choice of brachytherapy schedules to replace low dose rate treatments

    International Nuclear Information System (INIS)

    Visser, Andries G.; Aardweg, Gerard J.M.J. van den; Levendag, Peter C.

    1996-01-01

    Purpose: Pulsed dose rate (PDR) brachytherapy is a new type of afterloading brachytherapy (BT) in which a continuous low dose rate (LDR) treatment is simulated by a series of 'pulses,' i.e., fractions of short duration (less than 0.5 h) with intervals between fractions of 1 to a few hours. At the Dr. Daniel den Hoed Cancer Center, the term 'PDR brachytherapy' is used for treatment schedules with a large number of fractions (at least four per day), while the term 'fractionated high dose rate (HDR) brachytherapy' is used for treatment schedules with just one or two brachytherapy fractions per day. Both treatments can be applied as alternatives for LDR BT. This article deals with the choice between PDR and fractionated HDR schedules and proposes possible fractionation schedules. Methods and Materials: To calculate HDR and PDR fractionation schedules with the intention of being equivalent to LDR BT, the linear-quadratic (LQ) model has been used in an incomplete repair formulation as given by Brenner and Hall, and by Thames. In contrast to earlier applications of this model, both the total physical dose and the overall time were not kept identical for LDR and HDR/PDR schedules. A range of possible PDR treatment schedules is presented, both for booster applications (in combination with external radiotherapy (ERT) and for BT applications as a single treatment. Because the knowledge of both α/β values and the half time for repair of sublethal damage (T (1(2)) ), which are required for these calculations, is quite limited, calculations regarding the equivalence of LDR and PDR treatments have been performed for a wide range of values of α/β and T (1(2)) . The results are presented graphically as PDR/LDR dose ratios and as ratios of the PDR/LDR tumor control probabilities. Results: If the condition that total physical dose and overall time of a PDR treatment must be exactly identical to the values for the corresponding LDR treatment regimen is not applied, there appears

  4. Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

    International Nuclear Information System (INIS)

    Richter, Daniel; Saito, Nami; Chaudhri, Naved; Härtig, Martin; Ellerbrock, Malte; Jäkel, Oliver; Combs, Stephanie E.; Habermehl, Daniel; Herfarth, Klaus; Durante, Marco; Bert, Christoph

    2014-01-01

    Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V 95 ) and 107% (V 107 ) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V 95 and V 107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V 95 > 87%, SD < 3%) and overdose (mean V 107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment

  5. Evaluation and distribution of doses received by Cuban population due to environmental sources of radioactivity

    International Nuclear Information System (INIS)

    Zerquera, Juan T.; Prendes Alonso, Miguel; Fernandez Gomez, Isis M.; Lopez Bejerano, Gladys

    2008-01-01

    Full text: In the frame of a national research project supported by the Nuclear Energy Agency of the Ministry of Science, Technology and Environment of the Republic of Cuba doses received by Cuban population due to the exposure to existing in the environment sources of radiation were assessed. Direct measurements of sources representing 90% of average total doses to world population according to UNSCEAR data were made and estimations of doses were obtained for the different components of the total dose: doses due to the exposure to cosmic radiation, external terrestrial radiation, potassium contained in human body and inhalation and ingestion of radionuclides present in the environment. Using the obtained results it was made an estimation of total doses to Cuban population due to environmental radiation sources and the contributions of different dose components were assessed. This was carried out through a Monte Carlo simulation of the total doses using the parameter of dose distributions obtained for the different contributors (components) to total dose. On the basis of the estimations the average total effective dose to Cuban population due to the exposure to environmental sources was estimated as 1.1 ± 0.3 mSv per year. This low dose value is in the range of doses estimated by UNSCEAR for world population due to natural background and can be explained by the specific of Cuban environment: a majority of the population living at the sea level or at low altitudes, relative low content of primordial radionuclides in soils and high ventilation rates in dwellings. All the instructions specified in the Call for Abstracts should be taken into account. e/ 41 and 457. (author)

  6. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  7. The total ozone and UV solar radiation over Stara Zagora, Bulgaria

    Science.gov (United States)

    Mendeva, B. D.; Gogosheva, Ts. N.; Petkov, B. H.; Krastev, D. G.

    The results from direct ground-based solar UV irradiance measurements and the total ozone content (TOC) over Stara Zagora (42° 25'N, 25° 37'E), Bulgaria are presented. During the period 1999-2003 the TOC data show seasonal variations, typical for the middle latitudes - maximum in the spring and minimum in the autumn. The comparison between TOC ground-based data and Global Ozone Monitoring Experiment (GOME) satellite-borne ones shows a seasonal dependence of the differences between them. A strong negative relationship between the total ozone and the 305 nm wavelength irradiance was found. The dependence between the two variables is significant ( r = -0.62 ± 0.18) at 98% confidence level. The direct sun UV doses for some specific biological effects (erythema and eyes) are obtained. The estimation of the radiation amplification factor RAF shows that the ozone reduction by 1% increases the erythemal dose by 2.3%. The eye-damaging doses are more influenced by the TOC changes and in this case RAF = -2.7%. The amount of these biological doses depended on the solar altitude over the horizon. This dependence was not so strong when the total ozone content in the atmosphere was lower.

  8. Radiological protection in a patient during a total body irradiation procedure

    International Nuclear Information System (INIS)

    Hernandez O, J. O.; Hinojosa G, J.; Gomez M, E.; Balam de la Vega, J. A.; Deheza V, J. C.

    2010-09-01

    A technique used in the Service of Radiotherapy of the Cancer Center of the American British Cowdray Medical Center (ABC) for the bone marrow transplantation, is the total body irradiation. It is known that the dose calculation, for this irradiation type, is old, since the dosimetric calculation is carried out by hand and they exist infinity of techniques for the patients irradiation and different forms of protecting organs of risk, as well as a great uncertainty in the given dose. In the Cancer Center of the ABC Medical Center, was carried out an irradiation procedure to total body with the following methodology: Computerized tomography of the patient total body (two vacuum mattresses in the following positions: dorsal and lateral decubitus), where is combined the two treatment techniques anterior-posterior and bilateral, skin delineate and reference volumes, dose calculation with the planning system Xi O of CMS, dose determination using an ionization chamber and a lung phantom IMRT Thorax Phantom of the mark CIRS and dosimetry in vivo. In this work is presented the used treatment technique, the results, statistics and the actualization of the patient clinical state. (Author)

  9. Occupational radiation dose in Indonesia 1981-1986

    International Nuclear Information System (INIS)

    Hiswara, E.; Ismono, A.

    1993-01-01

    Occupational radiation dose in Indonesia 1981-1986. This paper presents the occupational radiation dose in Indonesia during the period of 1981-1986. The highest collective dose accurated in 1983 was calculated to be 2.68 man-Sv, with the maximum mean dose per worker, who received dose more than zero, was around 11.07 mSv in the same year. In 1985, a relative collective dose from medical occupations of 1.88 man mSv for 10 6 population was estimated based on its total collective dose of 0.31 man-mSv. The total number of workers who received annual collective dose less than 5 mSv varied from 97.0% in 1981 to 99.5% in 1986. As a group, the industrial occupations has considerably higher risk in receiving a dose than others. (authors). 11 refs., 7 tabs

  10. Serum level modifications of female sex hormones after radiocastration with different total doses

    International Nuclear Information System (INIS)

    Naujokat, B.; Rohloff, R.; Willich, N.; Eiermann, W.

    1988-01-01

    We determined serum level of estradiol, FSH and LH over a period of six to eight weeks after ovarian irradiation for castration with different doses (2x2.5 Gy/3x2.5 Gy/4x2.5 Gy) in 15 patients with metastatic breast cancer as compared to changes after ovarectomy in five patients. The time course of the changing estradiol-, FSH and LH-serum levels sigificantly depends on the ovarian dose. After radiological castration with a dose of 4x2.5 Gy = 10 Gy in four days the estrogen levels decrease within two to three weeks, and the FSH- and LH-levels increase after three to four weeks into the postmenopausal range. Therefore, the time course is not very different from changes after ovarectomy. (orig.) [de

  11. EFFECTIVE DOSE TO PATIENTS FROM THORACIC SPINE EXAMINATIONS WITH TOMOSYNTHESIS.

    Science.gov (United States)

    Svalkvist, Angelica; Söderman, Christina; Båth, Magnus

    2016-06-01

    The purposes of the present work were to calculate the average effective dose to patients from lateral tomosynthesis examinations of the thoracic spine, compare the results with the corresponding conventional examination and to determine a conversion factor between dose-area product (DAP) and effective dose for the tomosynthesis examination. Thoracic spine examinations from 17 patients were included in the study. The registered DAP and information about the field size for each projection radiograph were, together with patient height and mass, used to calculate the effective dose for each projection radiograph. The total effective doses for the tomosynthesis examinations were obtained by adding the effective doses from the 60 projection radiographs included in the examination. The mean effective dose was 0.47 mSv (range 0.24-0.81 mSv) for the tomosynthesis examinations and 0.20 mSv (range 0.07-0.29 mSv) for the corresponding conventional examinations (anteroposterior + left lateral projection). For the tomosynthesis examinations, a conversion factor between total DAP and effective dose of 0.092 mSv Gycm(-2) was obtained. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Global Collective Dose Commitments from Release of Long-Lived Radionuclides

    DEFF Research Database (Denmark)

    Gjørup, H. L.

    1977-01-01

    The concept of global collective dose commitment as a measure of total detriment from the release of radioactivity to the environment is outlined. Estimates are given of global collective dose commitments resulting from the release of 14C and uranium daughter products from the nuclear fuel cycle...... that the use of global collective dose commitments in differential cost-benefit analysis can lead to questionable results. In differential cost-benefit analysis it is suggested that population exposures should not simply be integrated irrespective of their time of occurrence, but that a certain discount rate...

  13. Dose assessment, radioecology, and community interaction at former nuclear test sites

    International Nuclear Information System (INIS)

    Robison, W.L.

    1994-11-01

    The US conducted a nuclear testing program at Bikini and Enewetak Atolls in the Marshall Islands from 1946 through 1958. A total of 66 nuclear devices were tested--23 at Bikini Atoll (total yield of 77 megatons) and 43 at Enewetak Atoll (total yield of 33 megatons). This resulted in contamination of many of the islands at each atoll. The BRAVO test (yield 15 megatons) on March 1, 1954 contaminated several atolls to the east of Bikini Atoll some of which were inhabited. The author has conducted an experimental, monitoring, and dose assessment program at atolls in the northern Marshall Islands for the past 20 years. The goals have been to: (1) determine the radiological conditions at the atolls; (2) provide dose assessments for resettlement options and alternate living patterns; (3) develop and evaluate remedial measures to reduce the dose to people reinhabiting the atolls; and (4) discuss the results with each of the communities and the Republic of the Marshall Islands government officials to help them understand the data as a basis for resettlement decisions. The remaining radionuclides at the atolls that contribute any significant dose are 137 Cs, 90 Sr, 239+240 Pu, and 241 Am

  14. Allogeneic marrow transplantation following cyclophosphamide and escalating doses of hyperfractionated total body irradiation in patients with advanced lymphoid malignancies: a phase I/II trial

    International Nuclear Information System (INIS)

    Demirer, Taner; Petersen, Finn B.; Appelbaum, Frederick R.; Barnett, Todd A.; Sanders, Jean; Deeg, H. Joachim; Storb, Rainer; Doney, Kristine; Bensinger, William I.; Shannon-Dorcy, Kathleen; Buckner, C. Dean

    1995-01-01

    Purpose: To define the maximum tolerated dose (MTD) of unshielded total body irradiation (TBI) delivered from dual 60 C sources at an exposure rate of 0.08 Gy/min and given in thrice daily fractions of 1.2 Gy in patients with advanced lymphoid malignancies. Methods and Materials: Forty-four patients with a median age of 28 (range 6-48) years were entered into a Phase I/II study. All patients received cyclophosphamide (CY), 120 mg/kg administered over 2 days before TBI. Marrow from human leukocyte antigen (HLA) identical siblings was infused following the last dose of TBI. An escalation-deescalation schema designed to not exceed an incidence of 25% of Grade 3-4 regimen-related toxicities (RRTs) was used. The first dose level tested was 13.2 Gy followed by 14.4 Gy. Results: None of the four patients at the dose level of 13.2 Gy developed Grade 3-4 RRT. Two of the first eight patients receiving 14.4 Gy developed Grade 3-4 RRT, establishing this as the MTD. An additional 32 patients were evaluated at the 14.4 Gy level to confirm these initial observations. Of 40 patients receiving 14.4 Gy, 13 (32.5%) developed Grade 3-4 RRTs; 46% in adults and 12% in children. The primary dose limiting toxicity was Grade 3-4 hepatic toxicity, which occurred in 12.5% of patients. Noninfectious Grade 3-4 interstitial pneumonia syndrome occurred in 5% of patients. The actuarial probabilities of event-free survival, relapse, and nonrelapse mortality at 2 years were 0.10, 0.81, and 0.47, respectively, for patients who received 14.4 Gy of TBI. Conclusions: The outcome for patients receiving 14.4 Gy of TBI was not different from previous studies of other CY and TBI regimens in patients with advanced lymphoid malignancies. These data showed that the incidence of Grade 3-4 RRTs in adults was greater than the 25% maximum set as the goal of this study, suggesting that 13.2 Gy is a more appropriate dose of TBI for adults, while 14.4 Gy is an appropriate dose for children

  15. The Dose Response Relationship for Radiation Carcinogenesis

    Science.gov (United States)

    Hall, Eric

    2008-03-01

    case of radiation oncology, modern innovations such as Intensity Modulated Radiation Oncology or Proton Therapy both result in a substantial total-body dose to the patient, which must result in an increased incidence of second cancers. The technology exists to reduce these total body doses and the problem needs to be addressed.

  16. Linac-based total body irradiation (TBI) with volumetric modulated arc therapy (VMAT)

    Science.gov (United States)

    Tas, B.; Durmus, I. F.; Okumus, A.; Uzel, O. E.

    2017-02-01

    To evaluate dose distribution of Volumetric modulated arc therapy (VMAT) planning tecnique using Versa HD® lineer accelerator to deliver Total Body Irradiation (TBI) on the coach. Eight TBI patient's Treatment Planning System (TPS) were performed with dual arc VMAT for each patient. The VMAT-TBI consisted of three isocentres and three dual overlapping arcs. The prescribed dose was 12 Gy. Mean dose to lung and kidney were restricted less than 10 Gy and max. dose to lens were restricted less than 6 Gy. The plans were verified using 2D array and ion chamber. The comparison between calculation and measurement were made by γ-index analysis and absolute dose. An average total delivery time was determined 923±34 seconds and an average MU was determined 2614±228 MUs for dual arc VMAT. Mean dose to lungs was 9.7±0.2 Gy, mean dose to kidneys was 8.8±0.3 Gy, max. dose to lens was 5.5±0.3 Gy and max. dose was 14.6±0.3 Gy, HI of PTV was 1.13±0.2, mean dose to PTV was 12.6±1.5 Gy and mean γ-index pass rate was %97.1±1.9. The results show that the tecnique for TBI using VMAT on the treatment coach is feasible.

  17. ELDRS Characterization for a Very High Dose Mission

    Science.gov (United States)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  18. Long-term results of total lymphoid irradiation in the treatment of cardiac allograft rejection

    International Nuclear Information System (INIS)

    Wolden, Suzanne L.; Tate, David J.; Hunt, Sharon A.; Strober, Samuel; Hoppe, Richard T.

    1997-01-01

    Purpose: To evaluate the short and long-term effects of total lymphoid irradiation (TLI) in the treatment of cardiac transplant rejection. Methods and Materials: Between 1986 and 1995, 48 courses of TLI were delivered to 47 cardiac transplant patients. In 37 patients, TLI was administered for intractable allograft rejection despite conventional therapy while 10 patients received TLI prophylactically. The prescribed radiation dose was 8 Gy in 0.8 Gy fractions twice weekly to mantle and inverted-Y plus spleen fields. Postirradiation follow-up ranged from 6 months to 9.1 years, with a mean of 3.1 years. Results: The actual mean dose was 7.3 Gy delivered over a mean of 39 days. Fifty-six percent of patients required treatment delay or abbreviation because of thrombocytopenia, leukopenia, infection, or unrelated problems. In patients treated for intractable rejection, rejection rates dropped from 0.46 to 0.14 and to 0.06 episodes/patient/month before, during, and after TLI (p < 0.0001). Rejection rates continued to drop throughout follow-up. Prednisone requirements decreased from 0.41 mg/kg before treatment to 0.21 mg/kg afterward (p < 0.0001). The ratio of helper to cytotoxic-suppressor T-cells decreased during TLI from 1.33 to 0.89, and remained low at 0.44, 2-4 months after treatment. Infection rates were not increased and two patients developed malignancy. Rejection rates were high during prophylactic treatment and this protocol was abandoned. Three-year actuarial survival after irradiation was 60% for patients with intractable rejection and 70% for the prophylactic cohort. Conclusion: TLI is an effective treatment for control of intractable cardiac rejection. Episodes of rejection and steroid dosage requirements are decreased for up to 9.1 years. A possible mechanism of action is long term alteration in T-lymphocyte subsets. Patients experience transient bone marrow suppression but no increase in infection or bleeding. Long-term complications of TLI are not

  19. Comparison of three techniques for skin total irradiation with electrons

    International Nuclear Information System (INIS)

    Batista, Delano V.S.; Bardella, Lucia H.; Rosa, Luiz A.R. da

    2011-01-01

    This paper compared three techniques of skin total irradiation with electrons: 1) horizontal positioning, 2) vertical positioning - rotatory technique and 3) vertical positioning - six fields technique. For that, a anthropomorphic phantom was positioned according to the recommendation for each technique and was i radiated at the linear accelerator by using the 6 MeV electrons. Radiochromic films were positioned on the surface in various regions of the phantom for measurement of absorbed dose. A ionization chamber was positioned inside of equivalent issue plates for dose evaluation due to the photons produced by electron stopping. The technique 2 and 3 have shown too similar in the results and number or discrepant points (8 and 10 respectively) of prescription lower than the technique 1 (22 points). The total body dose of photons of the 1, 2 and 3 techniques was 2.2%, 5.3% and 5.2% respectively

  20. ATG-Fresenius treatment and low-dose tacrolimus: results of a randomized controlled trial in liver transplantation.

    Science.gov (United States)

    Benítez, C E; Puig-Pey, I; López, M; Martínez-Llordella, M; Lozano, J J; Bohne, F; Londoño, M C; García-Valdecasas, J C; Bruguera, M; Navasa, M; Rimola, A; Sánchez-Fueyo, A

    2010-10-01

    We report the results of a prospective randomized controlled trial in liver transplantation assessing the efficacy and safety of antithymocyte globulin (ATG-Fresenius) plus tacrolimus monotherapy at gradually decreasing doses. Patients were randomized to either: (a) standard-dose tacrolimus plus steroids;or (b) peritransplant ATG-Fresenius plus reduced-dose tacrolimus monotherapy followed by weaning of tacrolimus starting 3 months after transplantation. The primary end-point was the achievement of very low-dose tacrolimus (every-other-day or once daily dose with Fresenius group but no benefits in terms of improved renal function, lower metabolic complications or increased prevalence of tolerance-related biomarkers were observed. In conclusion, the use of ATG-Fresenius and tacrolimus at gradually decreasing doses was associated with a high rate of rejection, did not allow for the administration of very low doses of tacrolimus and failed to provide detectable clinical benefits. ClinicalTrials.gov identifier: NCT00436722. © 2010 The Authors Journal compilation © 2010 The American Society of Transplantation and the American Society of Transplant Surgeons.

  1. Measurement of radiation dose with a PC-based instrument

    International Nuclear Information System (INIS)

    Jangland, L.; Neubeck, R.

    1994-01-01

    The purpose of this study was to investigate in what way the introduction of Digital Subtraction Angiography has influenced absorbed doses to the patient and personnel. Calculation of the energy imparted to the patient, ε, was based on measurements of the dose-area product, tube potential and tube current which were registered with a PC-based instrument. The absorbed doses to the personnel were measured with TLD. The measurements on the personnel were made only at the digital system. The results indicate large variations in ε between different types of angiographic examinations of the same type. The total ε were similar on both systems, although the relative contribution from image acquisition and fluoroscopy were different. At the conventional system fluoroscopy and image acquisition contributed almost equally to the total ε. At the digital system 25% of the total ε was due to fluoroscopy and 75% to image acquisition. The differences were due to longer fluoroscopic times on the conventional system, mainly due to lack of image memory and road mapping, and lower ε/image, due to lower dose settings to the film changer compared to the image intensifier on the digital system. 11 refs., 8 figs., 9 tabs

  2. Noise and dose modeling for pediatric CT optimization: preliminary results

    International Nuclear Information System (INIS)

    Miller Clemente, Rafael A.; Perez Diaz, Marlen; Mora Reyes, Yudel; Rodriguez Garlobo, Maikel; Castillo Salazar, Rafael

    2008-01-01

    Full text: A Multiple Linear Regression Model was developed to predict noise and dose in computed tomography pediatric imaging for head and abdominal examinations. Relative values of Noise and Volumetric Computed Tomography Dose Index was used to estimate de model respectively. 54 images of physical phantoms were performed. Independent variables considered included: phantom diameter, tube current and kilovolts, x ray beam collimation, reconstruction diameter and equipment's post processing filters. Predicted values show good agreement with measurements, which were better in noise model (R 2 adjusted =0.953) than the dose model (R 2 adjusted =0.744). Tube current, object diameter, beam collimation and reconstruction filter were identified as the most influencing factors in models. (author)

  3. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  4. The dependence of radiation response on the dose per fraction

    International Nuclear Information System (INIS)

    Joiner, M.C.

    1989-01-01

    The linear-quadratic (LQ) model explains the dependence of total dose in a fractionated course on the dose per fraction, in a very wide range of tumour and normal tissue studies, providing the dose per fraction remains above 2 Gy. In the range 2-1 Gy per fraction, some experimental studies show less increase in total dose than predicted by LQ; a probable explanation is incomplete repair between fractions given 2 seen between 1 and 0.1 Gy per fraction. This cannot be explained by incomplete repair; a modified LQ model where α decreases sharply with increasing dose per fraction in the range 0-1 Gy fits these data. The basic LQ model describes data from neutron fractionation studies, so the relationship between relative biological effectiveness (RBE) and X-ray dose per fraction can be expressed in terms of LQ parameters and fitted directly to RBE data. Results from different experiments, different assays and both top-up and full-course fractionation techniques, can all be included in one analysis. (author)

  5. Absorbed doses to patients from angioradiology

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez-Romero, R; Hernandez-Armas, J [Servicio de Fisica Medica, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain); Diaz-Romero, F [Servicio de Radiodiagnostico, Hospital Universitario de Canarias, La Laguna, Tenerife (Spain)

    2001-03-01

    The aim of study was to know patients doses exposes when three different procedures of angioradiology were carried out. The explorations considered were drainage biliary, varicocele embolization and dacriocistography made in the Radiodiagnostic Service at the University Hospital of Canary Islands, Tenerife (Spain). In total 14 patients were studied. The measurements were made using large area transmission ionisation chamber which gives the values of Dose Area Product (DAP). In addition, thermoluminescent dosimeters type TLD-100 were used in anthropomorphic phantom in order to obtain values of organ doses when the phantom was submitted to the same procedures rather than the actual patients. Furthermore, the Effdose program was used to estimate the effective doses in the procedures conditions. The values for DAP were in the range of 70-300 for drainage biliary, 43-180 for varicocele embolization and 1.4-9 for dacriocistography. The organ doses measured with TLD-100 were higher than the corresponding values estimated by Effdose program. The results for varicocele embolization were higher than other published data. In the case of drainage biliary procedure, the values were closed to other published results. It was not possible to find data for dacriocistography from other authors. (author)

  6. Absorbed doses to patients from angioradiology

    International Nuclear Information System (INIS)

    Rodriguez-Romero, R.; Hernandez-Armas, J.; Diaz-Romero, F.

    2001-01-01

    The aim of study was to know patients doses exposes when three different procedures of angioradiology were carried out. The explorations considered were drainage biliary, varicocele embolization and dacriocistography made in the Radiodiagnostic Service at the University Hospital of Canary Islands, Tenerife (Spain). In total 14 patients were studied. The measurements were made using large area transmission ionisation chamber which gives the values of Dose Area Product (DAP). In addition, thermoluminescent dosimeters type TLD-100 were used in anthropomorphic phantom in order to obtain values of organ doses when the phantom was submitted to the same procedures rather than the actual patients. Furthermore, the Effdose program was used to estimate the effective doses in the procedures conditions. The values for DAP were in the range of 70-300 for drainage biliary, 43-180 for varicocele embolization and 1.4-9 for dacriocistography. The organ doses measured with TLD-100 were higher than the corresponding values estimated by Effdose program. The results for varicocele embolization were higher than other published data. In the case of drainage biliary procedure, the values were closed to other published results. It was not possible to find data for dacriocistography from other authors. (author)

  7. Dosimetric verification of helical tomotherapy for total scalp irradiation

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Soisson, Emilie; Metcalfe, Peter; Rosenfeld, Anatoly B.; Tome, Wolfgang A.

    2008-01-01

    Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface (≤2 mm depth) bolus or a custom thermoplastic helmet is used.

  8. Some aspects of time-dose relationships

    International Nuclear Information System (INIS)

    Sugawara, Tadashi; Koito, Kazumitsu; Aihara, Toshinori

    1985-01-01

    One hundred thirty-seven patients with non-small cell lung cancers, 57 with oral cavity cancers and 98 with postoperative breast cancers treated with external radiotherapy from 1974 to 1980 were analyzed to determine optimal trends of time-dose relationships. Superiorities of fractionation factors were examined by comparing the relative local recurrence or expire rates among the subgroups prognostically homogenized in each entities of the diseases. Faborable fractionation factors for the former two diseases were those in which treatment was given in shortened over-all times, and frequently with low fraction dose to the considerably high daily dose. These results indicate the superiority of accelerated fractionation regime to conventional one in the treatment of those diseases. In contrast, any optimal trend was not found with postoperative breast cancers but total dose administered more than 43 Gy. (author)

  9. THE ANALYSIS OF TOTAL EXPENSES AT 1000 LEI TOTAL REVENUES AND OF THE RESULT OF THE GROWTH OF THEIR EFFICIENCY

    Directory of Open Access Journals (Sweden)

    LĂPĂDUŞI MIHAELA LOREDANA

    2013-12-01

    Full Text Available act The analysis of the company’s expenses is mainly important in the management and control activity, because it highlights the way in which are used the resources (material, human, financial and the impact of their allocation on the company’s performances. The optimization of the level of costs or the their reduction, where it is possible, without affecting the quality of the products and working conditions of the activity, represent the primary objectives of the management of companies.[9] Expenses have been and will remain one of the key indicators of a company requiring continuous application of a control and monitoring mechanism because when it comes to expenses we never speak of their growth, but their reduction. This reduction is the main objective of any economic agent that will result in increasing the efficiency of the entire activity. The costs of a company reflect in cash the total consumption of material, human and financial resources used in manufacturing and selling of the products. The level, dynamics and structure of these expenses reflect synthetically the activity of industrial enterprises when using effectively the available resources. The purpose of this article is to analyze synthetically a company's expenses efficiency based on the efficiency ratio of total expenses at 1000 lei total revenues and the purpose of the article results in a set of conclusions that will highlight a number of important issues concerning the role and the importance of the efficiency of total expenses related to total revenue, as well as the result of the growth of the efficiency of total expenses.

  10. Selective fallopian tube catheterisation in female infertility: clinical results and absorbed radiation dose

    International Nuclear Information System (INIS)

    Nakamura, K.; Ishiguchi, T.; Maekoshi, H.; Ando, Y.; Tsuzaka, M.; Tamiya, T.; Suganuma, N.; Ishigaki, T.

    1996-01-01

    Clinical results of fluoroscopic fallopian tube catheterisation and absorbed radiation doses during the procedure were evaluated in 30 infertility patients with unilateral or bilateral tubal obstruction documented on hysterosalpingography. The staged technique consisted of contrast injection through an intrauterine catheter with a vacuum cup device, ostial salpingography with the wedged catheter, and selective salpingography with a coaxial microcatheter. Of 45 fallopian tubes examined, 35 (78 %) were demonstrated by the procedure, and at least one tube was newly demonstrated in 26 patients (87 %). Six of these patients conceived spontaneously in the follow-up period of 1-11 months. Four pregnancies were intrauterine and 2 were ectopic. This technique provided accurate and detailed information in the diagnosis and treatment of tubal obstruction in infertility patients. The absorbed radiation dose to the ovary in the average standardised procedure was estimated to be 0.9 cGy. Further improvement in the X-ray equipment and technique is required to reduce the radiation dose. (orig.). With 3 figs., 3 tabs

  11. DOSE-ESCALATED EXTERNAL BEAM RADIOTHERAPY DURING HORMONO-RADIOTHERAPY FOR PROSTATE CANCER

    Directory of Open Access Journals (Sweden)

    Yu. V. Gumenetskaya

    2016-01-01

    Full Text Available Introduction. The introduction of modern technologies of conformal external beam radiotherapy (EBRT into clinical practice for the treatment of prostate cancer requires proper quality assurance measures as well as a careful analysis of both the efficacy and toxicity data of treatments. The purpose of this study was to inves- tigate tolerance and the immediate efficacy of conformal dose-escalated EBRT during hormono-radiotherapy for prostate cancer. material and methods. The study involved 156 prostate cancer patients treated with EBRT. Among them, 30 patients received a total dose of 70 Gy, and in 126 patients the total dose was esca- lated to 72-76 Gy (median total dose - 74.0 Gy. Fifty-nine patients received intensity modulated radiation therapy. Results. The prescribed course of treatment was completed in all the patients with prostate cancer. Acute radiation-induced bladder reactions (RTOG were observed in 50 (32.1 % patients, of whom 48 (30.8 % experienced grade I reactions, and 2 (1.3 % experienced grade II reactions. Eighteen (11.5 % patients had radiation-induced rectum reactions, not above grade I. The development of grade II dysuric phenomena necessitated treatment interruption only in two patients. Of 9 (5.8 % patients who had late bladder complica- tions (RTOG/EORTC, 8 (5.1 % patients developed grade I complications, and one (0.6 % patient developed grade II complications. Of 11 (7.1 % patients who had rectum complications, 8 (5.1 % patients developed grade I complications, and 3 (1.9 % patients developed grade II complications. No patients experienced the increase in toxicity of treatment during dose escalation up to a total dose exceeding 70 Gy. During the follow-up period, only one patient developed recurrent disease. Conclusion. The results of our study suggest acceptable levels of toxicity following a continuous course of dose-escalated EBRT given in conjunction with hormono-radiotherapy to prostate cancer patients. Further

  12. Small dose multi-fractionation therapy, its radiobiological aspects and clinics

    International Nuclear Information System (INIS)

    Iwai, Hiroshi; Katagiri, Shiro; Furuhata, Akihiko; Fukusi, Itsuhisa

    1979-01-01

    Recent radiobiological data reveal that cell killings by small dose fractionation are almost due to nonrepairable damage with low oxygen enhancement ratio. Then, Small dose multi-fractionation method suggests a higher therapeutic-ratio than that in conventional high dose fractionated irradiation. Using these data of radiobiology, intermittent irradiations three times a day, four hours interval, with 60 - 80 rads for multi-fractionation, with high total doses of 7,200 - 7,500 rads/6.5 - 7 weeks mainly on bladder, laryngeal and esophageal tumour are applied. The results obtained are slightly improved. (author)

  13. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    International Nuclear Information System (INIS)

    Willemsen, U.F.; Knesewitsch, P.; Kreisig, T.; Pickardt, C.R.; Kirsch, C.M.

    1993-01-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  14. Effective dose and cancer risk in PET/CT exams

    International Nuclear Information System (INIS)

    Pinto, Gabriella M.; Sa, Lidia Vasconcellos de

    2013-01-01

    Due to the use of radiopharmaceutical positron-emitting in PET exam and realization of tomography by x-ray transmission in CT examination, an increase of dose with hybrid PET/CT technology is expected. However, differences of doses have been reported in many countries for the same type of procedure. It is expected that the dose is an influent parameter to standardize the protocols of PET/CT. This study aimed to estimate the effective doses and absorbed in 65 patients submitted to oncological Protocol in a nuclear medicine clinic in Rio de Janeiro, considering the risk of induction of cancer from the scan. The CT exam-related doses were estimated with a simulator of PMMA and simulated on the lmPACT resistance, which for program effective dose, were considered the weight factors of the lCRP 103. The PET exam doses were estimated by multiplying the activity administered to the patient with the ICRP dose 80 factors. The radiological risk for cancer incidence were estimated according to the ICRP 103. The results showed that the effective dose from CT exam is responsible for 70% of the effective total in a PET/CT scan. values of effective dose for the PET/CT exam reached average values of up to 25 mSv leading to a risk of 2, 57 x 10 -4 . Considering that in staging of oncological diseases at least four tests are performed annually, the total risk comes to 1,03x 10 -3

  15. Survey of food radioactivity and estimation of internal dose from ingestion in China

    International Nuclear Information System (INIS)

    Zhang Jingyuan; Zhu Hongda; Han Peizhen

    1988-01-01

    In order to provide necessary bases for establishing 'Radionuclide Concentration Limits in Food stuffs', survey on radionuclide contents in Chinese food and estimation of internal dose from ingestion were carried out with the cooperation of 30 radiation protection establishments during the period 1982-1986. Activity concentrations in 14 categories (27 kinds) of Chinese food for 22 radionuclides were determined. In the light of three principal types of Chinese diet, food samples were collected from normal radiation background areas in 14 provinces or autonomous regions and three similarly elevated natural background areas. Annual intake by ingestion and resultant committed dose equivalents to general public for 15 radionuclides in these areas were estimated. In normal background areas the total annual intake of the 15 radionuclides by the public (adlut males) is about 4.2 x 10 4 Bq, and the resultant total committed dose equivalent is about 3.43 x 10 -4 Sv, but in two elevated natural background area the public annual intake and resulting committed dose equivalents for some natural radionulides are much higher than those in normal areas, while no obvious radiocontamination was discoveried relative contribution of each food category or each radionuclide to the total are discussed

  16. A 0.18 micrometer CMOS Thermopile Readout ASIC Immune to 50 MRAD Total Ionizing Dose (SI) and Single Event Latchup to 174MeV-cm(exp 2)/mg

    Science.gov (United States)

    Quilligan, Gerard T.; Aslam, Shahid; Lakew, Brook; DuMonthier, Jeffery J.; Katz, Richard B.; Kleyner, Igor

    2014-01-01

    Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.

  17. Population dose commitments due to radioactive releases from nuclear power plant sites in 1980

    International Nuclear Information System (INIS)

    Baker, D.A.; Peloquin, R.A.

    1983-08-01

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1980. In addition doses derived from the shutdown reactors at the Three Mile Island site were included. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways ranged from a high of 40 person-rem to a low of 0.02 person-rem with an arithmetic mean of 4 person-rem. The total population dose for all sites was estimated at 180 person-rem for the 96 million people considered at risk

  18. Dose measurements in the treatment of mycosis fungoides with total skin irradiation using a 4 MeV electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Poli, M.E.R. [Hospital Real e Benemerita Sociedade Portuguesa de Beneficencia (Brazil); Todo, A.S.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, CNEN/SP Travessa R, Sao Paulo (Brazil)

    2000-05-01

    The total skin irradiation (TSI) is one of the most efficient techniques in the treatment administered with curative intent of the mycosis fungoides. The cure may be obtained in 10% to 40% of cases. The original Stanford University technique, created in 1960, was applied in a 4.8 MeV linear accelerator, that provided 2.5 MeV electrons in the patient, by the use of 4 couple beams with the patient placed in front of the beam, 3 meters distant from the apparatus. In this work we describe a 4 MeV electrons beam treatment method. We intend to improve the uniformity of the dose in the patient, as well, to reduce the problems with the overlapping treatment fields, that occurs in conventional treatment that uses 1 meter of focus-skin distance, and the treatment time to the patient. Only one modification was done in the apparatus: the dose rate for this treatment was doubled. The patient is placed on a rotative base and he assumes successively 6 positions: stand up and perpendicular to the beam, distant 2.83 meters from the gantry, with 60 degrees of interval between the rotations. In each position, the patient receives a couple of beams (the beam angulation is 19.5 degrees above the transversal axis in the middle of the patient and 19.5 degrees below it). The dosimetric data obtained were compared to the international protocols (AAPM). The delivered doses in the patient were measured with thermoluminescent dosimeters placed on skin surface and with Kodak XV-2 films placed between different slabs of an anthropomorphic phantom. The dose distribution in the phantom shows a good uniformity, in all thickness of interest, so it is possible to use this technique in the treatment of the mycosis fungoides as well Kaposi's sarcoma. (author)

  19. Recovery Profiles of T-Cell Subsets Following Low-Dose Total Body Irradiation and Improvement With Cinnamon

    International Nuclear Information System (INIS)

    Zheng, Xiaodan; Guo, Yuqi; Wang, Lei; Zhang, Honghai; Wang, Shaobo; Wang, Li; An, Lei; Zhou, Xianbin; Li, Xia; Yao, Chengfang

    2015-01-01

    Purpose: Inefficient T-cell reconstitution from x-ray–induced immune damage reduces antitumor response. To understand the profile of T-cell reconstitution after irradiation will overcome the barrier of antitumor immunity. This study aimed to identify the recovery profile of T-cell subsets following x-ray irradiation and to highlight the role of cinnamon on efficient T-cell restoration postexposure in the antitumor response. Methods and Materials: CD3"+, CD8"+, and CD4"+ T cells and Th1, Th2, Th17, and regulatory T (Treg) cells were evaluated at different time points after single low-dose total body irradiation (SLTBI) with or without cinnamon treatments. T-bet, GATA3, RORγt, and Foxp3 signaling specific for Th1, Th2, Th17, and Treg were also analyzed by RT-PCR assay. The effects of cinnamon on efficient T-cell subset reconstitution was confirmed in a lung melanoma model in irradiated mice. Results: Reconstitution of CD4"+ T cells was delayed more than that of CD8"+ T cells in T-cell restoration after SLTBI. The production of IFNγ by Th1 or Tc1 cells was sharply decreased and was accompanied by reduced T-bet mRNA, even when total T-cell numbers had recovered; the frequencies of Th17 and Treg cells and their specific transcription factors (RORγt and Foxp3, respectively) were obviously increased. Irradiation-induced inefficient T-cell reconstitution impaired the antitumor capacities in the lung melanoma model. Pretreatment with cinnamon in irradiated mice accelerated the generation of Th1 and reduced the differentiation of Treg cells by activating T-bet and limiting transcriptions of Foxp3. Improvement resulting from cinnamon pretreatment on the efficient T-cell recovery profile from SLTBI promoted antitumor immunity in the lung melanoma model. Conclusions: T-cell reconstitution from SLTBI was characterized by impaired Th1 and elevated Th17 and Treg cells. Cinnamon effectively improved the imbalance of T-cell subsets by promoting the proliferation of Th1 and

  20. Recovery Profiles of T-Cell Subsets Following Low-Dose Total Body Irradiation and Improvement With Cinnamon

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xiaodan [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); School of Medicine and Life Science, University of Jinan-Shandong Academy of Medical Science, Jinan (China); Guo, Yuqi [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Wang, Lei [Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan (China); Zhang, Honghai [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Wang, Shaobo [Shandong University, Jinan (China); Wang, Li [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); An, Lei [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); School of Medicine and Life Science, University of Jinan-Shandong Academy of Medical Science, Jinan (China); Zhou, Xianbin; Li, Xia [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China); Yao, Chengfang, E-mail: yaocf9941@163.com [Key Laboratory for Tumor Immunology and Traditional Chinese Medicine Immunology, Institute of Basic Medicine, Shandong Academy of Medical Sciences, Jinan (China)

    2015-12-01

    Purpose: Inefficient T-cell reconstitution from x-ray–induced immune damage reduces antitumor response. To understand the profile of T-cell reconstitution after irradiation will overcome the barrier of antitumor immunity. This study aimed to identify the recovery profile of T-cell subsets following x-ray irradiation and to highlight the role of cinnamon on efficient T-cell restoration postexposure in the antitumor response. Methods and Materials: CD3{sup +}, CD8{sup +}, and CD4{sup +} T cells and Th1, Th2, Th17, and regulatory T (Treg) cells were evaluated at different time points after single low-dose total body irradiation (SLTBI) with or without cinnamon treatments. T-bet, GATA3, RORγt, and Foxp3 signaling specific for Th1, Th2, Th17, and Treg were also analyzed by RT-PCR assay. The effects of cinnamon on efficient T-cell subset reconstitution was confirmed in a lung melanoma model in irradiated mice. Results: Reconstitution of CD4{sup +} T cells was delayed more than that of CD8{sup +} T cells in T-cell restoration after SLTBI. The production of IFNγ by Th1 or Tc1 cells was sharply decreased and was accompanied by reduced T-bet mRNA, even when total T-cell numbers had recovered; the frequencies of Th17 and Treg cells and their specific transcription factors (RORγt and Foxp3, respectively) were obviously increased. Irradiation-induced inefficient T-cell reconstitution impaired the antitumor capacities in the lung melanoma model. Pretreatment with cinnamon in irradiated mice accelerated the generation of Th1 and reduced the differentiation of Treg cells by activating T-bet and limiting transcriptions of Foxp3. Improvement resulting from cinnamon pretreatment on the efficient T-cell recovery profile from SLTBI promoted antitumor immunity in the lung melanoma model. Conclusions: T-cell reconstitution from SLTBI was characterized by impaired Th1 and elevated Th17 and Treg cells. Cinnamon effectively improved the imbalance of T-cell subsets by promoting the

  1. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  2. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-12-07

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.

  3. Reducing dose to the lungs through loosing target dose homogeneity requirement for radiotherapy of non small cell lung cancer.

    Science.gov (United States)

    Miao, Junjie; Yan, Hui; Tian, Yuan; Ma, Pan; Liu, Zhiqiang; Li, Minghui; Ren, Wenting; Chen, Jiayun; Zhang, Ye; Dai, Jianrong

    2017-11-01

    It is important to minimize lung dose during intensity-modulated radiation therapy (IMRT) of nonsmall cell lung cancer (NSCLC). In this study, an approach was proposed to reduce lung dose by relaxing the constraint of target dose homogeneity during treatment planning of IMRT. Ten NSCLC patients with lung tumor on the right side were selected. The total dose for planning target volume (PTV) was 60 Gy (2 Gy/fraction). For each patient, two IMRT plans with six beams were created in Pinnacle treatment planning system. The dose homogeneity of target was controlled by constraints on the maximum and uniform doses of target volume. One IMRT plan was made with homogeneous target dose (the resulting target dose was within 95%-107% of the prescribed dose), while another IMRT plan was made with inhomogeneous target dose (the resulting target dose was more than 95% of the prescribed dose). During plan optimization, the dose of cord and heart in two types of IMRT plans were kept nearly the same. The doses of lungs, PTV and organs at risk (OARs) between two types of IMRT plans were compared and analyzed quantitatively. For all patients, the lung dose was decreased in the IMRT plans with inhomogeneous target dose. On average, the mean dose, V5, V20, and V30 of lung were reduced by 1.4 Gy, 4.8%, 3.7%, and 1.7%, respectively, and the dose to normal tissue was also reduced. These reductions in DVH values were all statistically significant (P target dose could protect lungs better and may be considered as a choice for treating NSCLC. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Review of time-dose effects in radiation therapy

    International Nuclear Information System (INIS)

    Peschel, R.E.; Fischer, J.J.

    1980-01-01

    A historical review of conventional fractionation offers little confidence that such treatment is optimal for all tumors. Thus manipulation of time-dose schedules may provide a relatively inexpensive yet potentially useful technique for improving therapeutic results in radiation therapy. Consideration of basic radiobiological principles and animal model data illustrates the complex and heterogeneous nature of normal tissue and tumor response to time-dose effects and supports the hypothesis that better time-dose prescriptions can be found in clinical practice. The number of possible time-dose prescriptions is very large, and a review of the clinical trials using nonconventional fractionation demonstrates that the sampled portion of the total three-dimensional space of time, fraction number, and dose has been very small. Only carefully designed clinical trials can establish the therapeutic advantage of a new treatment schedule, and methods for selecting the most promising schedules are discussed. The use of simple data reduction formulas for time-dose effects should be discarded since they ignore the very complexity and heterogeneity of tissues and tumors which may form the basis of improved clinical results

  5. [Single intravenous tranexamic acid dose to reduce blood loss in primary total knee replacement].

    Science.gov (United States)

    Sanz-Reig, J; Parra Ruiz, B; Ferrández Martínez, J; Martínez López, J F

    2016-01-01

    To evaluate the effectiveness and safety of a single intravenous dose of tranexamic acid in order to reduce blood loss in total knee replacement. Prospective observational study of the administration of tranexamic acid in patients undergoing primary total knee arthroplasty from November 2013 to February 2015, in which an autologous blood recovery system was used. The study included 98 patients, distributed into two groups of 49 patients according to whether or not they received intravenous tranexamic acid. The primary endpoint was the number of patients requiring autologous transfusion from the recovery system autologous blood recovery system. No drop-outs were recorded during follow-up. There were no significant differences between groups as regards the preoperative and hospital variables. The mean preoperative haemoglobin and haematocrit at 24 and 48 hours postoperatively were similar in both groups. The average volume of bleeding in the autologous blood recovery system and estimated average blood loss was lower in patients who had been administered tranexamic acid, with significant differences. No patients in the group that was administered tranexamic acid required blood autotransfusion. The transfusion rate was zero in the two groups. No adverse events related to the administration of tranexamic acid were recorded. Intravenous administration of tranexamic acid, according to the described protocol, has presented a non-autotransfusion or allo-transfusion rate of 100%, with no increased incidence of thrombotic events. Thus, its use in this group of patients is recommended. The indication should be individualized, its use justified in the patient medical records, and informed consent is mandatory. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  6. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    International Nuclear Information System (INIS)

    Yaparpalvi, R; Mynampati, D; Kuo, H; Garg, M; Tome, W; Kalnicki, S

    2016-01-01

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V_2_0 and V_5 to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm"3. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V_2_0 (+3.1%) and V_5 (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates attributable to algorithm

  7. SU-F-T-600: Influence of Acuros XB and AAA Dose Calculation Algorithms On Plan Quality Metrics and Normal Lung Doses in Lung SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Yaparpalvi, R; Mynampati, D; Kuo, H; Garg, M; Tome, W; Kalnicki, S [Montefiore Medical Center, Bronx, NY (United States)

    2016-06-15

    Purpose: To study the influence of superposition-beam model (AAA) and determinant-photon transport-solver (Acuros XB) dose calculation algorithms on the treatment plan quality metrics and on normal lung dose in Lung SBRT. Methods: Treatment plans of 10 Lung SBRT patients were randomly selected. Patients were prescribed to a total dose of 50-54Gy in 3–5 fractions (10?5 or 18?3). Doses were optimized accomplished with 6-MV using 2-arcs (VMAT). Doses were calculated using AAA algorithm with heterogeneity correction. For each plan, plan quality metrics in the categories- coverage, homogeneity, conformity and gradient were quantified. Repeat dosimetry for these AAA treatment plans was performed using AXB algorithm with heterogeneity correction for same beam and MU parameters. Plan quality metrics were again evaluated and compared with AAA plan metrics. For normal lung dose, V{sub 20} and V{sub 5} to (Total lung- GTV) were evaluated. Results: The results are summarized in Supplemental Table 1. PTV volume was mean 11.4 (±3.3) cm{sup 3}. Comparing RTOG 0813 protocol criteria for conformality, AXB plans yielded on average, similar PITV ratio (individual PITV ratio differences varied from −9 to +15%), reduced target coverage (−1.6%) and increased R50% (+2.6%). Comparing normal lung doses, the lung V{sub 20} (+3.1%) and V{sub 5} (+1.5%) were slightly higher for AXB plans compared to AAA plans. High-dose spillage ((V105%PD - PTV)/ PTV) was slightly lower for AXB plans but the % low dose spillage (D2cm) was similar between the two calculation algorithms. Conclusion: AAA algorithm overestimates lung target dose. Routinely adapting to AXB for dose calculations in Lung SBRT planning may improve dose calculation accuracy, as AXB based calculations have been shown to be closer to Monte Carlo based dose predictions in accuracy and with relatively faster computational time. For clinical practice, revisiting dose-fractionation in Lung SBRT to correct for dose overestimates

  8. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    Science.gov (United States)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  9. Subantimicrobial dose doxycycline effects on osteopenic bone loss: microbiologic results.

    Science.gov (United States)

    Walker, Clay; Puumala, Susan; Golub, Lorne M; Stoner, Julie A; Reinhardt, Richard A; Lee, Hsi-Ming; Payne, Jeffrey B

    2007-08-01

    Based on microbiologic concerns, the safety of a 24-month regimen of subantimicrobial dose doxycycline (SDD; 20 mg twice a day) was evaluated in postmenopausal osteopenic women with periodontitis in a double-blind, placebo-controlled, randomized clinical trial. Subgingival samples were collected from two sites (probing depth > or = 5 mm) in each of 128 subjects at baseline, with the same sites resampled at the conclusion of the 2-year period. The samples were enumerated on selective and non-selective media and on doxycycline (4 microg/ml) medium. Up to five different colonial morphologies were subcultured from the doxycycline medium, identified to species, and susceptibilities determined to doxycycline and five other antibiotics. Data were analyzed for microbial differences in total colony forming units (CFU), periodontal and opportunistic pathogens, and changes in species and in susceptibilities of isolates recovered on doxycycline medium. There was no significant evidence that changes in total anaerobic counts over the treatment period (P = 0.96) differed between treatment groups. Likewise, periodontal pathogens, opportunistic pathogens, or normal flora did not differ descriptively between groups. Although there was a significant increase (P or = 16 microg/ml) decreased over the 24-month period in both groups and did not differ between the treatment groups (SDD: 79% to 76%; placebo: 83% to 70%; P = 0.2). There were no significant differences (P >0.28 for each) in the change in cross-resistance between the groups for doxycycline and the other five antibiotics. No antimicrobial effect on the subgingival flora was detected following treatment with SDD for 24 months, relative to baseline or to placebo. The increase in initial resistance (at 4 microg/ml) did not translate into a significant increase in the percent resistant to doxycycline (MIC > or = 16 microg/ml) for patients in the SDD group.

  10. Total and single doses influence the effectiveness of radiotherapy in palliative treatment of plasmacytoma

    Energy Technology Data Exchange (ETDEWEB)

    Stoelting, T.; Knauerhase, H.; Klautke, G. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Kundt, G. [Inst. for Medical Informatics and Biometry, Univ. of Rostock (Germany); Fietkau, R. [Dept. of Radiotherapy, Univ. of Rostock (Germany); Dept. of Radiotherapy, Univ. of Erlangen (Germany)

    2008-09-15

    Purpose: in a retrospective analysis of radiotherapy of plasmacytomas, the effectiveness and the prognostic factors in regard to pain reduction and recalcification were evaluated. Patients and methods: 138 patients (70 women, 68 men; 15-86 years, median 61 years) were irradiated at 272 target volumes (TVs) from January 1970 to December 2003. Results: in 192/225 TVs (85.3%), there was a pain reduction. The recalcification rate was 44.7% (51/114 TVs). Significant parameters for pain relief in the multivariate analysis were completeness of therapy (odds ratio [OR] 87.8; p < 0.001 vs. interruption), patients < 60 years (OR 23.0; p < 0.001 vs. {>=} 70 years), and a single dose of 2 Gy (OR 11.0; p = 0.027 vs. 4-15.0 Gy). Significant parameters for recalcification in the multivariate analysis were concurrent chemotherapy (OR 12.3; p < 0.001 vs. no chemotherapy), no fractures in the TV (OR 5.9; p < 0.004 vs. fracture), and a dose of 40-< 50 Gy (OR 21.9; p = 0.035 vs. < 30 Gy) or {>=} 50 Gy (OR 26.4; p = 0.033 vs. < 30 Gy). Conclusion: radiotherapy is a very effective palliative treatment. Patients with a reduced general condition, with multiple bone lesions and a poor prognosis profit from short-term schemes (e.g., 1 x 8 Gy to 10 x 3 Gy). Patients in good general condition with a life expectancy of > 1 year and an osteolysis at risk of fracture, should be treated with doses up to 40-50 Gy (20-25 x 2 Gy), in order to achieve the best possible recalcification and pain relief. (orig.)

  11. Late biological effects of ionizing radiation as influenced by dose, dose rate, age at exposure, and genetic sensitivity to neoplastic transformation

    International Nuclear Information System (INIS)

    Spalding, J.F.; Prine, J.R.; Tietjen, G.L.

    1978-01-01

    A most comprehensive investigation is in progress at the Los Alamos Scientific Laboratory to study the late biological effects of whole-body exposure to gamma irradiation as they may be influenced by total dose, dose rate, age at exposure, and genetic background. Strain C57B1/6J mice of four age groups (newborn, 2, 6, and 15 months) were given five doses (20, 60, 180, 540, and 1620 rad) of gamma rays, with each dose being delivered at six dose rates (0.7, 2.1, 6.3, 18.9, 56.7 rad/day and 25 rad/min). Forty to sixty mice were used in each of the approximately 110 dose/dose-rate and age combinations. The study was done in two replications with an equal number of mice per replication. Strain RF/J mice were used in a companion study to investigate the influence of genetic background on the type and magnitude of effect. Results of the first and second replications of the 15-month-old age group and data on the influence of genetic background on biological response have been completed, and the results show no significant life shortening within the dose and dose-rate range used

  12. Comparative influence of dose rate and radiation nature, on lethality after big mammals irradiation

    International Nuclear Information System (INIS)

    Destombe, C.; Le Fleche, Ph.; Grasseau, A.; Reynal, A.

    1997-01-01

    For the same dose and the 30 days lethality as biological criterion, the dose rate influence is more important than the radiation nature on the results of an big mammals total body irradiation. (authors)

  13. Text book of dose calculation for operators

    International Nuclear Information System (INIS)

    Aoyagi, Haruki; Gonda, Kozo

    1979-07-01

    This is a text book of dose calculation for the operators of the reprocessing factory of Power Reactor and Nuclear Fuel Development Corporation. The radiations considered are beta-ray and gamma-ray. The method used is a point attenuation nuclear integral method. Radiation sources are considered as the assemblies of point sources. Dose from each point source is calculated, then, total dose is obtained by the integration for all sources. Attenuation is calculated by considering the attenuation owing to distance and the absorption by absorbers. The build-up factor is introduced for the correction for scattered gamma-ray. The build-up factor is given in a table for various scatterers. The operators are able to calculate dose by themselves. The results of integral calculation expressed with formulas are given in graphs. (Kato, T.)

  14. Intercomparison programme of dose calibration used in nuclear medicine center in Malaysia

    International Nuclear Information System (INIS)

    Norhayati Abdullah; Abdul Aziz Mohd Ramli; Muhammad Jamal Md Isa; Siti Sara Deraman; Shahrul Azlan Azizan; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of dose calibrator is significant in order to ensure that the equipment operates optimally and provides accurate and reliable measurements of the total activity of radiopharmaceuticals before being administered into the patients. Through this work, the response between the secondary standard dose calibrator and users radioactivity measurement are obtained by using standard sources such as 57 Co, 133 Ba, 1 '3 7 Cs and 60 Co. The calibration procedure is in accordance with the NPLs (National Physical Laboratory, United Kingdom) document; Guide No. 93[1] and the IAEA (International Atomic Energy Agency) Technical Report Series No. 454 [2] is used as a reference for maintaining secondary standard dose calibrator. A total of 21 units of dose calibrator from eight nuclear medicine departments comprising five hospitals, two medical centres and one production laboratory were calibrated. The measurement results were inter compared with the national standard equipment and a baseline data was established for future comparison as well as dose optimization purposes. Results showed that the overall response of all dose calibrators are within NPLs tolerance limit of ±10 % except for 5 units which exceed the tolerance limit for radionuclide 133 Ba and 57 Co.(author)

  15. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F., E-mail: falima@cnen.gov.br, E-mail: mendes_sb@hotmail.com [Centro Regional de Ciências Nucleares, (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Melo, Ana Maria M.A., E-mail: july_cgm@yahoo.com.br [Universidade Federal de Pernambuco (UFPE), Vitória de Santo Antão, PE (Brazil). Centro Acadêmico de Vitória

    2017-07-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  16. Validation of dose-response calibration curve for X-Ray field of CRCN-NE/CNEN: preliminary results

    International Nuclear Information System (INIS)

    Silva, Laís Melo; Mendonç, Julyanne Conceição de Goes; Andrade, Aida Mayra Guedes de; Hwang, Suy F.; Mendes, Mariana Esposito; Lima, Fabiana F.; Melo, Ana Maria M.A.

    2017-01-01

    It is very important in accident investigations that accurate estimating of absorbed dose takes place, so that it contributes to medical decisions and overall assessment of long-term health consequences. Analysis of chromosome aberrations is the most developed method for biological monitoring, and frequencies of dicentric chromosomes are related to absorbed dose of human peripheral blood lymphocytes using calibration curves. International Atomic Energy Agency (IAEA) recommends that each biodosimetry laboratory sets its own calibration curves, given that there are intrinsic differences in protocols and dose interpretations when using calibration curves produced in other laboratories, which could add further uncertainties to dose estimations. The Laboratory for Biological Dosimetry CRCN-NE recently completed dose-response calibration curves for X ray field. Curves of chromosomes dicentrics and dicentrics plus rings were made using Dose Estimate. This study aimed to validate the calibration curves dose-response for X ray with three irradiated samples. Blood was obtained by venipuncture from healthy volunteer and three samples were irradiated by x-rays of 250 kVp with different absorbed doses (0,5Gy, 1Gy and 2Gy). The irradiation was performed at the CRCN-NE/CNEN Metrology Service with PANTAK X-ray equipment, model HF 320. The frequency of dicentric and centric rings chromosomes were determined in 500 metaphases per sample after cultivation of lymphocytes, and staining with Giemsa 5%. Results showed that the estimated absorbed doses are included in the confidence interval of 95% of real absorbed dose. These Dose-response calibration curves (dicentrics and dicentrics plus rings) seems valid, therefore other tests will be done with different volunteers. (author)

  17. Total Skin Electron Beam for Primary Cutaneous T-cell Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Elsayad, Khaled; Kriz, Jan; Moustakis, Christos; Scobioala, Sergiu; Reinartz, Gabriele; Haverkamp, Uwe; Willich, Normann [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany); Weishaupt, Carsten [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Stadler, Rudolf [Department of Dermatology, Johannes-Wesling-Klinikum Minden, Minden (Germany); Sunderkötter, Cord [Department of Dermatology, University Hospital of Muenster, Muenster (Germany); Eich, Hans Theodor, E-mail: Hans.Eich@ukmuenster.de [Department of Radiation Oncology, University Hospital of Muenster, Muenster (Germany)

    2015-12-01

    Purpose: Recent trials with low-dose total skin electron beam (TSEB) therapy demonstrated encouraging results for treating primary cutaneous T-cell lymphoma (PCTCL). In this study, we assessed the feasibility of different radiation doses and estimated survival rates of different pathologic entities and stages. Methods and Materials: We retrospectively identified 45 patients with PCTCL undergoing TSEB therapy between 2000 and 2015. Clinical characteristics, treatment outcomes, and toxicity were assessed. Results: A total of 49 courses of TSEB therapy were administered to the 45 patients. There were 26 pathologically confirmed cases of mycosis fungoides (MF) lymphoma, 10 cases of Sézary syndrome (SS), and 9 non-MF/SS PCTCL patients. In the MF patients, the overall response rate (ORR) was 92% (50% complete remission [CR]), 70% ORR in SS patients (50% CR), and 89% ORR in non-MF/SS patients (78% CR). The ORR for MF/SS patients treated with conventional dose (30-36 Gy) regimens was 92% (63% CR) and 75% (25% CR) for low-dose (<30-Gy) regimens (P=.09). In MF patients, the overall survival (OS) was 77 months with conventional dose regimens versus 14 months with low-dose regimens (P=.553). In SS patients, the median OS was 48 versus 16 months (P=.219), respectively. Median event-free survival (EFS) for MF in conventional dose patients versus low-dose patients was 15 versus 8 months, respectively (P=.264) and 19 versus 3 months for SS patients (P=.457). Low-dose regimens had shorter treatment time (P=.009) and lower grade 2 adverse events (P=.043). A second TSEB course was administered in 4 MF patients with 100% ORR. There is a possible prognostic impact of supplemental/boost radiation (P<.001); adjuvant treatment (P<.001) and radiation tolerability (P=.021) were detected. Conclusions: TSEB therapy is an efficacious treatment modality in the treatment of several forms of cutaneous T-cell lymphoma. There is a nonsignificant trend to higher and longer clinical benefit

  18. Dose from drinking water Finland

    International Nuclear Information System (INIS)

    Maekelaeinen, Ilona; Salonen, Laina; Huikuri, Pia; Arvela, Hannu

    1999-01-01

    The dose from drinking water originates almost totally from naturally occurring radionuclides in the uranium-238 series, the most important nuclide being radon-222. Second comes lead-210, and third polonium-210. The mean age-group-weighted dose received by ingestion of drinking water is 0.14 mSv per year. More than half of the total cumulative dose of 750 manSv is received by the users of private wells, forming 13% of the population. The most exposed group comprises the users of wells drilled in bedrock, who receive 320 manSv while comprising only 4% of the population. The calculated number of annual cancer incidences due to drinking water is very sensitive to the dose-conversion factors of ingested radon used, as well as to the estimated lung cancer incidences caused by radon released from water into indoor air. (au)

  19. Low doses of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C.; Arthur, Valter; Arthur, Paula B.; Franco, Caio H.

    2017-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  20. Low doses of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C., E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio H. [Universidade Federal de São Paulo (UNIFESP), SP (Brazil). Departamento de Microbiologia, Imunologia e Parasitologia

    2017-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  1. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  2. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  3. Capecitabine based postoperative accelerated chemoradiation of pancreatic carcinoma. A dose-escalation study

    International Nuclear Information System (INIS)

    Morganti, Alessio G.; Picardi, Vincenzo; Ippolito, Edy; Massaccesi, Mariangela; Macchia, Gabriella; Deodato, Francesco; Caravatta, Luciana; Tambaro, Rosa; Mignogna, Samantha; Cellini, Numa; Valentini, Vincenzo; Mattiucci, Gian Carlo; Di Lullo, Liberato; Giglio, Gianfranco; Caprino, Paola; Sofo, Luigi; Ingrosso, Marcello

    2010-01-01

    The objective of this study was to evaluate the safety of escalating up to 55 Gy within five weeks, the dose of external beam radiotherapy to the previous tumor site concurrently with a fixed daily dose of capecitabine, in patients with resected pancreatic cancer. Material and methods. Patients with resected pancreatic carcinoma were eligible for this study. Capecitabine was administered at a daily dose of 1600 mg/m 2 . Regional lymph nodes received a total radiation dose of 45 Gy with 1.8 Gy per fractions. The starting radiation dose to the tumor bed was 50.0 Gy (2.0 Gy/fraction, 25 fractions). Escalation was achieved up to a total dose of 55.0 Gy by increasing the fraction size by 0.2 Gy (2.2 Gy/fraction), while keeping the duration of radiotherapy to five weeks (25 fractions). A concomitant boost technique was used. Dose limiting toxicity (DLT) was defined as any grade>3 hematologic toxicity, grade>2 liver, renal, neurologic, gastrointestinal, or skin toxicity, by RTOG criteria, or any toxicity producing prolonged (> 10 days) radiotherapy interruption. Results and discussion. Twelve patients entered the study (median age: 64 years). In the first cohort (six patients), no patient experienced DLT. Similarly in the second cohort, no DLT occurred. All 12 patients completed the planned regimen of therapy. Nine patients experienced grade 1-2 nausea and/or vomiting. Grade 2 hematological toxicity occurred in four patients. The results of our study indicate that a total radiation dose up to 55.0 Gy/5 weeks can be safely administered to the tumor bed, concurrently with capecitabine (1600 mg/m 2 ) in patients with resected pancreatic carcinoma.

  4. Analysis of bias effects on the total ionizing dose response in a 180 nm technology

    International Nuclear Information System (INIS)

    Liu Zhangli; Hu Zhiyuan; Zhang, Zhengxuan; Shao Hua; Chen Ming; Bi Dawei; Ning Bingxu; Zou Shichang

    2011-01-01

    The effects of gamma ray irradiation on the shallow trench isolation (STI) leakage current in a 180 nm technology are investigated. The radiation response is strongly influenced by the bias modes, gate bias during irradiation, substrate bias during irradiation and operating substrate bias after irradiation. We found that the worst case occurs under the ON bias condition for the ON, OFF and PASS bias mode. A positive gate bias during irradiation significantly enhances the STI leakage current, indicating the electric field influence on the charge buildup process during radiation. Also, a negative substrate bias during irradiation enhances the STI leakage current. However a negative operating substrate bias effectively suppresses the STI leakage current, and can be used to eliminate the leakage current produced by the charge trapped in the deep STI oxide. Appropriate substrate bias should be introduced to alleviate the total ionizing dose (TID) response, and lead to acceptable threshold voltage shift and subthreshold hump effect. Depending on the simulation results, we believe that the electric field distribution in the STI oxide is the key parameter influencing bias effects on the radiation response of transistor. - Highlights: → ON bias is the worst bias condition for the ON, PASS and OFF bias modes. → Larger gate bias during irradiation leads to more pronounced characteristic degradation. → TID induced STI leakage can be suppressed by negative operating substrate bias voltage. → Negative substrate bias during irradiation leads to larger increase of off-state leakage. → Electric field in the STI oxide greatly influences the device's radiation effect.

  5. Bremsstrahlung doses from natural uranium ingots

    International Nuclear Information System (INIS)

    Anderson, J. L.; Hertel, N. E.

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and Bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and Bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from ∼51-84 μSv h -1 and 17-95 μSv h -1 using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and Bremsstrahlung were the same order of magnitude for each object. (authors)

  6. Bremsstrahlung doses from natural uranium ingots.

    Science.gov (United States)

    Anderson, Jeri L; Hertel, Nolan E

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from approximately 51-84 microSv h(-1) and 17-95 microSv h(-1) using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and bremsstrahlung were the same order of magnitude for each object.

  7. Cardiovascular effects, induction and recovery characteristics and alfaxalone dose assessment in alfaxalone versus alfaxalone-fentanyl total intravenous anaesthesia in dogs.

    Science.gov (United States)

    Dehuisser, Virginie; Bosmans, Tim; Kitshoff, Adriaan; Duchateau, Luc; de Rooster, Hilde; Polis, Ingeborgh

    2017-11-01

    To compare cardiovascular effects and anaesthetic quality of alfaxalone alone or in combination with a fentanyl constant rate infusion (CRI) when used for total intravenous anaesthesia (TIVA) in dogs. Prospective, blinded, randomized, experimental study. A group of 12 intact female dogs. Following intramuscular dexmedetomidine (10 μg kg -1 ) and methadone (0.1 mg kg -1 ) administration, anaesthesia was induced intravenously with alfaxalone (2 mg kg -1 ) (group AP) or alfaxalone (2 mg kg -1 ) preceded by fentanyl (2 μg kg -1 ) (group AF). Anaesthetic maintenance was obtained with an alfaxalone variable rate infusion (VRI) started at 0.15 mg kg -1 minute -1 (group AP) or an alfaxalone VRI (same starting rate) combined with a CRI of fentanyl (10 μg kg -1 hour -1 ) (group AF). The alfaxalone VRI was adjusted every 5 minutes, based on clinical assessment. Cardiovascular parameters (recorded every 5 minutes) and recovery characteristics (using a numerical rating scale) were compared between groups. A mixed model statistical approach was used to compare the mean VRI alfaxalone dose and cardiovascular parameters between groups; recovery scores were analysed using the Wilcoxon rank-sum test (α = 0.05). The mean CRI alfaxalone dose for anaesthetic maintenance differed significantly between treatments [0.16 ± 0.01 mg kg -1 minute -1 (group AP) versus 0.13 ± 0.01 mg kg -1 minute -1 (group AF)]. Overall heart rate, systolic, mean and diastolic arterial pressures were lower in group AF than in group AP (p < 0.0001, p = 0.0058, p < 0.0001 and p < 0.0001, respectively. Recovery quality scores did not differ significantly and were poor in both groups. In combination with a fentanyl CRI, an alfaxalone TIVA provides a cardiovascular stable anaesthesia in dogs. The addition of fentanyl results in a significant dose reduction. The quality of anaesthetic recovery remains poor. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia

  8. Integrated boost IMRT with FET-PET-adapted local dose escalation in glioblastomas. Results of a prospective phase II study

    International Nuclear Information System (INIS)

    Piroth, M.D.; Pinkawa, M.; Holy, R.; Forschungszentrum Juelich GmbH

    2012-01-01

    Dose escalations above 60 Gy based on MRI have not led to prognostic benefits in glioblastoma patients yet. With positron emission tomography (PET) using [ 18 F]fluorethyl-L-tyrosine (FET), tumor coverage can be optimized with the option of regional dose escalation in the area of viable tumor tissue. In a prospective phase II study (January 2008 to December 2009), 22 patients (median age 55 years) received radiochemotherapy after surgery. The radiotherapy was performed as an MRI and FET-PET-based integrated-boost intensity-modulated radiotherapy (IMRT). The prescribed dose was 72 and 60 Gy (single dose 2.4 and 2.0 Gy, respectively) for the FET-PET- and MR-based PTV-FET (72 Gy) and PTV-MR (60 Gy) . FET-PET and MRI were performed routinely for follow-up. Quality of life and cognitive aspects were recorded by the EORTC-QLQ-C30/QLQ Brain20 and Mini-Mental Status Examination (MMSE), while the therapy-related toxicity was recorded using the CTC3.0 and RTOG scores. Median overall survival (OS) and disease-free survival (DFS) were 14.8 and 7.8 months, respectively. All local relapses were detected at least partly within the 95% dose volume of PTV-MR (60 Gy) . No relevant radiotherapy-related side effects were observed (excepted alopecia). In 2 patients, a pseudoprogression was observed in the MRI. Tumor progression could be excluded by FET-PET and was confirmed in further MRI and FET-PET imaging. No significant changes were observed in MMSE scores and in the EORTC QLQ-C30/QLQ-Brain20 questionnaires. Our dose escalation concept with a total dose of 72 Gy, based on FET-PET, did not lead to a survival benefit. Acute and late toxicity were not increased, compared with historical controls and published dose-escalation studies. (orig.)

  9. Integrated boost IMRT with FET-PET-adapted local dose escalation in glioblastomas. Results of a prospective phase II study

    Energy Technology Data Exchange (ETDEWEB)

    Piroth, M.D.; Pinkawa, M.; Holy, R. [RWTH Aachen University Hospital (Germany). Dept. of Radiation Oncology; Forschungszentrum Juelich GmbH (DE). Juelich-Aachen Research Alliance (JARA) - Section JARA-Brain] (and others)

    2012-04-15

    Dose escalations above 60 Gy based on MRI have not led to prognostic benefits in glioblastoma patients yet. With positron emission tomography (PET) using [{sup 18}F]fluorethyl-L-tyrosine (FET), tumor coverage can be optimized with the option of regional dose escalation in the area of viable tumor tissue. In a prospective phase II study (January 2008 to December 2009), 22 patients (median age 55 years) received radiochemotherapy after surgery. The radiotherapy was performed as an MRI and FET-PET-based integrated-boost intensity-modulated radiotherapy (IMRT). The prescribed dose was 72 and 60 Gy (single dose 2.4 and 2.0 Gy, respectively) for the FET-PET- and MR-based PTV-FET{sub (72 Gy)} and PTV-MR{sub (60 Gy)}. FET-PET and MRI were performed routinely for follow-up. Quality of life and cognitive aspects were recorded by the EORTC-QLQ-C30/QLQ Brain20 and Mini-Mental Status Examination (MMSE), while the therapy-related toxicity was recorded using the CTC3.0 and RTOG scores. Median overall survival (OS) and disease-free survival (DFS) were 14.8 and 7.8 months, respectively. All local relapses were detected at least partly within the 95% dose volume of PTV-MR{sub (60 Gy)}. No relevant radiotherapy-related side effects were observed (excepted alopecia). In 2 patients, a pseudoprogression was observed in the MRI. Tumor progression could be excluded by FET-PET and was confirmed in further MRI and FET-PET imaging. No significant changes were observed in MMSE scores and in the EORTC QLQ-C30/QLQ-Brain20 questionnaires. Our dose escalation concept with a total dose of 72 Gy, based on FET-PET, did not lead to a survival benefit. Acute and late toxicity were not increased, compared with historical controls and published dose-escalation studies. (orig.)

  10. Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation.

    Science.gov (United States)

    Storb, R; Raff, R F; Graham, T; Appelbaum, F R; Deeg, H J; Schuening, F G; Sale, G; Seidel, K

    1999-01-01

    We evaluated the marrow toxicity of 200 and 300 cGy total-body irradiation (TBI) delivered at 10 and 60 cGy/min, respectively, in dogs not rescued by marrow transplant. Additionally, we compared toxicities after 300 cGy fractionated TBI (100 cGy fractions) to that after single-dose TBI at 10 and 60 cGy/min. Marrow toxicities were assessed on the basis of peripheral blood cell count changes and mortality from radiation-induced pancytopenia. TBI doses studied were just below the dose at which all dogs die despite optimal support. Specifically, 18 dogs were given single doses of 200 cGy TBI, delivered at either 10 (n=13) or 60 (n=5) cGy/min. Thirty-one dogs received 300 cGy TBI at 10 cGy/min, delivered as either single doses (n=21) or three fractions of 100 cGy each (n=10). Seventeen dogs were given 300 cGy TBI at 60 cGy/min, administered either as single doses (n=5) or three fractions of 100 cGy each (n=10). Within the limitations of the experimental design, three conclusions were drawn: 1) with 200 and 300 cGy single-dose TBI, an increase of dose rate from 10 to 60 cGy/min, respectively, caused significant increases in marrow toxicity; 2) at 60 cGy/min, dose fractionation resulted in a significant decrease in marrow toxicities, whereas such a protective effect was not seen at 10 cGy/min; and 3) with fractionated TBI, no significant differences in marrow toxicity were seen between dogs irradiated at 60 and 10 cGy/min. The reduced effectiveness of TBI when a dose of 300 cGy was divided into three fractions of 100 cGy or when dose rate was reduced from 60 cGy/min to 10 cGy/min was consistent with models of radiation toxicity that allow for repair of sublethal injury in DNA.

  11. Efficacy of Low-Dose Protocol in Follow-Up of Lymphoproliferative Disorders - Preliminary Results

    International Nuclear Information System (INIS)

    Popic-Ramac, J.; Brnic, Z.; Klasic, B.; Hebrang, A.; Knezevic, Z.

    2011-01-01

    Most medically-related radiation is caused by diagnostic examinations, in particular by computed tomography (CT). The purpose of this research is to reduce radiation doses faced by the population frequently exposed to such procedures-those with lymphoproliferative disorders. The research was conducted comparing radiation-exposition doses received by the radiosensitive organs (thyroid, lens, breast and gonad) using the standard thoracic CT protocol with the radiation received using the low-dose protocol, while maintaining display quality. The standard-dose thoracic protocol implies 120 kV and 150 mAs. The low-dose protocol was conducted on the same device using 120 kV and 30 mAs. We confirmed the hypothesis that the use of the low-dose thoracic CT protocol leads to a reduction in radiation dose without compromising display quality. It is further expected that a reduction in doses will reduce the risk of radiation-related mutations. (author)

  12. Tritium metabolism in newborn mice and estimation of the accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Saito, M; Ishida, M R

    1986-01-01

    Suckling mice received tritium from their mothers who were supplied with tritiated water as drinking water. After weaning, the offspring were sacrificed and the tritium concentration was determined for various organs and various molecular components including acid soluble component, lipid, RNA, DNA and protein. The accumulated dose for the period between 3 and 41 weeks after birth was calculated for various organs and the contributions of the acid insoluble components to the total dose estimated. The per cent contribution of the acid insoluble components to the total dose was organ specific and was between about 17% and 42%. The result indicates that the inhomogeneous distribution of tritium in subcellular structures needs to be taken into account. The contribution of organically bound tritium to dose is then comparable to that of tritium in the free water component.

  13. Hyperfractionated high-dose total body irradiation in bone marrow transplantation for Ph{sup 1}-positive acute lymphoblastic leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Akira; Ebihara, Yasuhiro; Mitsui, Tetsuo [Tokyo Univ. (Japan). Hospital of the Institute of Medical Science] [and others

    1998-12-01

    In two cases of Philadelphia-positive childhood acute lymphoblastic leukemia (Ph{sup 1} ALL), we performed allogeneic bone marrow transplantation (AlloBMT) with preconditioning regimen, including hyperfractionated high-dose total body irradiation (TBI) (13.5 Gy, in 9 fractions). Their disease statuses at BMT were hematological relapse in case 1 and molecular relapse in case 2. Bone marrow donors were unrelated in case 1, and HLA was a partially mismatched mother in case 2. Regimen-related toxicity was tolerable in both cases. Hematological recovery was rapid, and engraftment was obtained on day 14 in case 1 and on day 12 in case 2. BCR/ABL message in bone marrow disappeared on day 89 in case 1 and on day 19 in case 2 and throughout their subsequent clinical courses. Although short-term MTX and Cy-A continuous infusion were used for GVHD prophylaxis, grade IV GVHD was observed in case 1 and grade III in case 2. Both cases experienced hemorrhagic cystitis because of adenovirus type 11 infection. Although case 1 died of interstitial pneumonitis on day 442, case 2 has been free of disease through day 231. AlloBMT for Ph{sup 1} ALL with preconditioning regimen including hyperfractionated high-dose TBI is considered to be worth further investigation. (author)

  14. First Italian intercomparison on methodologies for dose assessment from internal contamination. Results and perspectives; Primo interconfronto italiano sulle metodiche di valutazione di dose da contaminazione interna: risultati e prospettive

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Battisti, P.; Tarroni [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1998-07-01

    In the frame of the MIDIA activities (coordination of whole body counters operating in Italy) an intercomparison on dose evaluation methods was promoted and carried out between October 1995 and March 1996 by 5 WBC centres. The main results related to the estimation of Intake and effective dose equivalent on the four case studies are reported. A comparison with European preliminary results is also presented. Finally perspectives related to the quality assurance of internal dosimetry estimates are indicated. [Italian] Vengono riportati i risultati delle valutazioni di Intake e di equivalente di dose nei centri MIDIA (coordinamento dei WBC operanti in Italia) per effettuare un interconfronto sui metodi di valutazione di dose da contaminazione interna utilizzando casi di studio reperiti in ambiente europeo. Vengono indicate le prospettive per la valutazione della qualita' della stima di dose in dosimetria interna.

  15. Dietary acrylamide exposure of the French population: results of the second French Total Diet Study.

    Science.gov (United States)

    Sirot, Véronique; Hommet, Frédéric; Tard, Alexandra; Leblanc, Jean-Charles

    2012-03-01

    Acrylamide is a heat-induced carcinogen compound that is found in some foods consequently to cooking or other thermal processes. In the second French Total Diet Study (TDS), acrylamide was analysed in 192 food samples collected in mainland France to be representative of the population diet and prepared "as consumed". Highest mean concentrations were found in potato chips/crisps (954 μg/kg), French fries and other fried potatoes (724 μg/kg), and salted biscuits other than potato chips (697 μg/kg). Exposure of general adult and child populations was assessed by combining analytical results with national consumption data. Mean acrylamide exposure was assessed to be 0.43±0.33 μg/kg of body weight (bw) per day for adults and 0.69±0.58 μg/kg bw/day for children. Although the exposure assessed is lower than in previous evaluations, the calculated margins of exposure, based on benchmark dose limits defined for carcinogenic effects, remain very low especially for young children (below 100 at the 95th percentile of exposure), indicating a health concern. It is therefore advisable to continue efforts in order to reduce dietary exposure to acrylamide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  17. Population dose commitments due to radioactive releases from nuclear power plant sites in 1983

    International Nuclear Information System (INIS)

    Baker, D.A.; Peloquin, R.A.

    1987-04-01

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1983. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teen-ager and adult) residing between 2 and 80 km from each of 52 sites. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each of the sites is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitments (from both liquid and airborne pathways) for each site ranged from a high of 45 person-rem to a low of 0.002 person-rem for the sites with plants operating throughout the year with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 170 person-rem for the 100 million people considered at risk

  18. nduced hyperlipidemic rats. Methods: Column chromatographic fractionation of butanol fraction of total methanol extract of leaves of Bauhinia variegata (Linn. yields four sub-fractions (sub-fraction A-D. All sub-fractions tested for their anti-hyperlipidemic activity. Sub-fractions administered at a dose of 65 mg/kg (oral to the Triton WR-1339 induced hyperlipidemic rats and total cholesterol, triglycerides, HDL, LDL and VLDL

    Directory of Open Access Journals (Sweden)

    Deepak Kumar

    2012-10-01

    Full Text Available Objective: To investigate the effect and evaluation of Anti-hyperlipidemic activity guided subfraction isolated from total methanolic extract of Bauhinia variegata (Linn. leaves on Triton WR-1339 induced hyperlipidemic rats. Methods: Column chromatographic fractionation of butanol fraction of total methanol extract of leaves of Bauhinia variegata (Linn. yields four subfractions (sub-fraction A-D. All sub-fractions tested for their anti-hyperlipidemic activity. Subfractions administered at a dose of 65 mg/kg (oral to the Triton WR-1339 induced hyperlipidemic rats and total cholesterol, triglycerides, HDL, LDL and VLDL level in the blood were checked. Results: Sub-fraction D showed significant reduction (P<0.05 among four sub-fraction in comparison with standard drug fenofibrate. Conclusions: From the above study it could be concluded that butanol sub-fraction D of Bauhinia variegata (Linn. not only have resulted in significant reduction in cholesterol, triglyceride, LDL, VLDL level but also increases the HDL level at a reduced dose level.

  19. Maximum tolerated dose in a phase I trial on adaptive dose painting by numbers for head and neck cancer

    International Nuclear Information System (INIS)

    Madani, Indira; Duprez, Fréderic; Boterberg, Tom; Van de Wiele, Christophe; Bonte, Katrien; Deron, Philippe; De Gersem, Werner; Coghe, Marc; De Neve, Wilfried

    2011-01-01

    Purpose: To determine the maximum tolerated dose (MTD) in a phase I trial on adaptive dose-painting-by-numbers (DPBN) for non-metastatic head and neck cancer. Materials and methods: Adaptive intensity-modulated radiotherapy was based on voxel intensity of pre-treatment and per-treatment [ 18 F]fluoro-2-deoxy-D-glucose positron emission tomography ( 18 F-FDG-PET) scans. Dose was escalated to a median total dose of 80.9 Gy in the high-dose clinical target volume (dose level I) and 85.9 Gy in the gross tumor volume (dose level II). The MTD would be reached, if ⩾33% of patients developed any grade ⩾4 toxicity (DLT) up to 3 months follow-up. Results: Between February 2007 and August 2009, seven patients at dose level I and 14 at dose level II were treated. All patients completed treatment without interruption. At a median follow-up for surviving patients of 38 (dose level I) and 22 months (dose level II) there was no grade ⩾4 toxicity during treatment and follow-up but six cases of mucosal ulcers at latency of 4–10 months, of which five (36%) were observed at dose level II. Mucosal ulcers healed spontaneously in four patients. Conclusions: Considering late mucosal ulcers as DLT, the MTD of a median dose of 80.9 Gy has been reached in our trial.

  20. Total integrated dose testing of solid-state scientific CD4011, CD4013, and CD4060 devices by irradiation with CO-60 gamma rays

    Science.gov (United States)

    Dantas, A. R. V.; Gauthier, M. K.; Coss, J. R.

    1985-01-01

    The total integrated dose response of three CMOS devices manufactured by Solid State Scientific has been measured using CO-60 gamma rays. Key parameter measurements were made and compared for each device type. The data show that the CD4011, CD4013, and CD4060 produced by this manufacturers should not be used in any environments where radiation levels might exceed 1,000 rad(Si).

  1. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Oral Tranexamic Acid Reduces Transfusions in Total Knee Arthroplasty.

    Science.gov (United States)

    Perreault, Roger E; Fournier, Christine A; Mattingly, David A; Junghans, Richard P; Talmo, Carl T

    2017-10-01

    Tranexamic acid (TXA) reduces intraoperative blood loss and transfusions in patients undergoing total knee arthroplasty. Although numerous studies demonstrate the efficacy of intravenous and topical TXA in these patients, few demonstrate the effectiveness and appropriate dosing recommendations of oral formulations. A retrospective cohort study was performed to evaluate differences in transfusion requirements in patients undergoing primary unilateral total knee arthroplasty with either no TXA (n = 866), a single-dose of oral TXA (n = 157), or both preoperative and postoperative oral TXA (n = 1049). Secondary outcomes included postoperative hemoglobin drop, total units transfused, length of stay, drain output, and cell salvage volume. Transfusion rates decreased from 15.4% in the no-oral tranexamic acid (OTA) group to 9.6% in the single-dose OTA group (P < .001) and 7% in the 2-dose group (P < .001), with no difference in transfusion rates between the single- and 2-dose groups (P = .390). In addition, postoperative hemoglobin drop was reduced from 4.2 g/dL in the no-OTA group to 3.5 g/dL in the single-dose group (P < .01) and to 3.4 g/dL in the 2-dose group (P < .01), without a difference between the single- and 2-dose groups (P = .233). OTA reduces transfusions, with greater ease of administration and improved cost-effectiveness relative to other forms of delivery. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  4. Evaluation of indoor radon equilibrium factor using CFD modeling and resulting annual effective dose

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2018-04-01

    The equilibrium factor is an important parameter for reasonably estimating the population dose from radon. However, the equilibrium factor value depended mainly on the ventilation rate and the meteorological factors. Therefore, this study focuses on investigating numerically the influence of the ventilation rate, temperature and humidity on equilibrium factor between radon and its progeny. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on indoor equilibrium factor. The variations of equilibrium factor with the ventilation, temperature and relative humidity are discussed. Moreover, the committed equivalent doses due to 218Po and 214Po radon short-lived progeny were evaluated in different tissues of the respiratory tract of the members of the public from the inhalation of indoor air. The annual effective dose due to radon short lived progeny from the inhalation of indoor air by the members of the public was investigated.

  5. Influence of dose distribution homogeneity on the tumor control probability in heavy-ion radiotherapy

    International Nuclear Information System (INIS)

    Wen Xiaoqiong; Li Qiang; Zhou Guangming; Li Wenjian; Wei Zengquan

    2001-01-01

    In order to estimate the influence of the un-uniform dose distribution on the clinical treatment result, the Influence of dose distribution homogeneity on the tumor control probability was investigated. Basing on the formula deduced previously for survival fraction of cells irradiated by the un-uniform heavy-ion irradiation field and the theory of tumor control probability, the tumor control probability was calculated for a tumor mode exposed to different dose distribution homogeneity. The results show that the tumor control probability responding to the same total dose will decrease if the dose distribution homogeneity gets worse. In clinical treatment, the dose distribution homogeneity should be better than 95%

  6. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: Dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1993, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. 9 patients were excluded from analysis secondary to co-morbidities or disease progression. 43 records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in (7(63)) (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to treat

  7. Post-treatment visual acuity in patients treated with episcleral plaque therapy for choroidal melanoma: dose and dose rate effects

    International Nuclear Information System (INIS)

    Jones, Robert; Gore, Elizabeth; Mieler, William; Murray, Kevin; Gillin, Michael; Albano, Katherine; Erickson, Beth

    1996-01-01

    Purpose: To determine the relationship between the long-term visual function and the dose and dose rates delivered to critical ocular structures in patients with choroidal melanoma treated with 125 I episcleral plaque radiotherapy. Methods and Materials: From 1987 to 1994, 63 patients underwent 125 I episcleral plaque application for the treatment of choroidal melanoma. Mean tumor height was 4.6 mm (range 1.7-8.3 mm). Plaques utilized were of COMS design. Doses and dose rates at the tumor apex, macula, and optic disc were obtained. Visual acuity data prior to and after plaque application was available for 52 patients. Nine patients were excluded from analysis secondary to co-morbidities or disease progression. Forty-three records were scored to assess if a decrease in visual acuity of ≥ 2 lines on a standard Snellen eye chart had occurred. Statistical analysis was performed using chi-square tests of significance. Results: Of the 63 total patients, 59 (93.7%) were alive at a median follow-up of 36 months. Local progression occurred in 7/63 (11.1%). Median dose and dose rate to the tumor apex were 90 Gy and 97.2 cGy/hr, respectively. Of the 43 patients with post-treatment visual acuity analysis, 28 (65.1%) experienced visual loss of ≥ 2 lines on a standard eye chart. Median time to altered visual acuity was 20 months. Median dose and dose rates to the macula in patients with a significant visual loss were 123.3 Gy and 122.5 cGy/hr, respectively, compared with 38 Gy and 51.9 cGy/hr in those without notable visual change. These differences reached statistical significance at a dose and dose rate to the macula of 82.0 Gy (p 125 I plaque brachytherapy for choroidal melanoma experienced favorable tumor control, but with a measurable incidence of decreased visual acuity. Both total dose and dose rates to the macula and optic disc correlated strongly with post-treatment visual outcome. This information may be valuable in decisions about the dose and dose rates used to

  8. Estimation of organ and effective dose due to Compton backscatter security scans

    International Nuclear Information System (INIS)

    Hoppe, Michael E.; Schmidt, Taly Gilat

    2012-01-01

    Purpose: To estimate organ and effective radiation doses due to backscatter security scanners using Monte Carlo simulations and a voxelized phantom set. Methods: Voxelized phantoms of male and female adults and children were used with the GEANT4 toolkit to simulate a backscatter security scan. The backscatter system was modeled based on specifications available in the literature. The simulations modeled a 50 kVp spectrum with 1.0 mm-aluminum-equivalent filtration and a previously measured exposure of approximately 4.6 μR at 30 cm from the source. Photons and secondary interactions were tracked from the source until they reached zero kinetic energy or exited from the simulation’s boundaries. The energy deposited in the phantoms’ respective organs was tallied and used to calculate total organ dose and total effective dose for frontal, rear, and full scans with subjects located 30 and 75 cm from the source. Results: For a full screen, all phantoms’ total effective doses were below the established 0.25 μSv standard, with an estimated maximum total effective dose of 0.07 μSv for full screen of a male child. The estimated maximum organ dose due to a full screen was 1.03 μGy, deposited in the adipose tissue of the male child phantom when located 30 cm from the source. All organ dose estimates had a coefficient of variation of less than 3% for a frontal scan and less than 11% for a rear scan. Conclusions: Backscatter security scanners deposit dose in organs beyond the skin. The effective dose is below recommended standards set by the Health Physics Society (HPS) and the American National Standards Institute (ANSI) assuming the system provides a maximum exposure of approximately 4.6 μR at 30 cm.

  9. Absorbed dose estimation of gonads resulting from fault work of staff during injection of radiopharmaceuticals to the patients

    International Nuclear Information System (INIS)

    Maleki, M.; Karimian, A.

    2012-01-01

    Radiopharmaceuticals are used in nuclear medicine in a variety of diagnostic and therapeutic procedures and generally delivered to the patient via intravenous injection. 201 Tl and 99m Tc are the two most used radiopharmaceuticals in nuclear medicine. The maximum activity injected to the patient in nuclear medicine for 201 Tl and 99m Tc is 5 and 20-25 mCi respectively. In this research by using Monte Carlo method and MCNPX code the absorbed dose to Gonads due to drop of radiopharmaceutical on foot thigh during injection to the patient has been calculated. The activity of 201 Tl and 99m Tc has been considered 1 and 5mCi respectively. The amount of absorbed dose in gonads for 99m Tc for male and female during 8 hours of work has been measured 0.37 and 0.055 μSv respectively. Also the amount of absorbed dose for 201 Tl during working hours at first day, second day and third day after work fault for male has been measured 0.387, 0.308 and 0.246 μSv and for female 0.06, 0.048 and 0.038 μSv respectively. The total dose in these three working days for male and female has been 0.941 and 0.146 μSv respectively. Since absorbed dose of gonads was far enough from the limits of ICRP, so it can be concluded that if a fault work occurs and even staff does not be aware there is no need to treat him. (authors)

  10. Medium dose rate brachytherapy for patients with cervical carcinoma; early result of a prospective study

    Directory of Open Access Journals (Sweden)

    Amouzegar Hashemi F

    2009-03-01

    Full Text Available "nBackground: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. "nMethods: Between March 2006 and July 2008, 140 patients with histologic diagnosis of cervical carcinoma referred to Tehran Cancer Institute; were treated with external beam radiotherapy (44-64 Gy to whole pelvis and MDR brachytherapy (8-30 Gy to Point A with a dose rate of 2.2±0.3 Gy/h. "nResults: 121 patients were followed up for a median time of 18 months (range: 9-39 m. There were 11%(6/54 local recurrence for surgery and adjuvant radiotherapy group; 25%(16/65 for radical radiotherapy group, and 19%(23/121 for all patients. Rectal and bladder complications incidence for all patients were 10%(12/121 and 13%(16/121 respectively. High grade complication was shown only in one patient in radical radiotherapy group. In this study 3-years disease free survival and overall survival were 73% and 92% respectively, and disease stage (p=0.007 and overall treatment time (p=0.05 were the significant factors affecting disease free survival. "nConclusions: Results of this series suggest that the use of external beam radiotherapy and MDR brachytherapy with about 20% dose reduction in comparison with LDR can be an acceptable technique with regard to local control and complications.

  11. Treatment of neuroblastoma. Role of total Body Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Dini, G; Perin, G P; Franzone, P; Corvo, R; Scarpati, D

    1986-01-01

    Advanced neuroblastoma, scarcely responsive to conventional therapies, can take advantage of high dose chemio-radiotherapic treatment followed by bone marrow transplant. Nineteen young patients underwent an ablative chemotherapy with high dose Vincristine and Melphalan plus Total Body Irradiation in Genoa, Italy; all of them underwent autologus bone marrow transplantation. Fourteen children were in complete remission (CR), 5 had residual disease. Thirteen are alive after a median of 7 months following transplant; 9 are in CR; 4 have disease; 1 died for toxicity; 5 for relapse. The results seem to suggest that ablative therapy should be given to patients in CR. Toxicity was not remarkable mainly as far as TBI is concerned.

  12. Hyperfractionated total body irradiation for bone marrow transplantation. Results in seventy leukemia patients with allogeneic transplants

    International Nuclear Information System (INIS)

    Shank, B.; Chu, F.C.H.; Dinsmore, R.

    1983-01-01

    From May, 1979 to March, 1981, 76 leukemia patients were prepared for bone marrow transplantation (BMT) with a new hyperfractionated total body irradiation (TBI) regimen (1320 cGy in 11 fractions, 3x/day), followed by cyclophosphamide, 60 mg/kg, for two days. Partial lung shielding was done on each treatment, with supplemental electron beam treatments of the chest wall to compensate, and of the testes, a sanctuary site. This regimen was initiated to potentially reduce fatal interstitial pneumonitis as well as decrease leukemic relapse. Overall actuarial survival at 1 year for acute non-lymphocytic leukemia (ANLL) patients is 63%, while relapse-free survival at 1 year is 53%. On the other hand, for acute lymphocytic leukemia (ALL) patients, there is no significant difference between relapse or remission patients with regard to overall survival or relapse-free survival, when relapse is defined as > 5% blasts in the marrow at the time of cytoreduction. Overall actuarial survival at 1 year for ALL is 61% and relapse-free survival is 45% at 1 year. Fatal interstitial pneumonitis has dropped to 18% compared with 50% in our previous single-dose TBI regimen (1000 cGy), in which the same doses of cyclophosphamide were given prior to TBI. In conclusion, not only has fatal interstitial pneumonitis been reduced by hyperfractionation and partial lung blocking, but there may be a survival advantage in ALL patients in relapse, who have a survival equal to that of remission patients. This may indicate a greater cell kill with the higher dose (1320 cGy) attained with this regimen, in these patients with a higher leukemic cell burden

  13. Experiences with using a concept of organ-dose combination as a basis for practical measures in radiation protection

    International Nuclear Information System (INIS)

    Wernli, C.

    1977-01-01

    The concept of organ-dose combination is presented and its practical consequences for working-place and personnel monitoring and for the improvement of working methods are shown. Two years of practical experience have demonstrated the applicability and usefullness of the concept and have resulted in a better concentration and economization of the monitoring and protection efforts. The values for external total body dose and skin dose, in special cases also those for hand dose and internal contamination, are combined to form a criterion for the total radiation detriment which is easy to use and interpret: each measured external or internal exposure is registered as a fraction of the appropriate maximum permissible annual limit (expressed as dose for external exposures and as activity for incorporations). This fraction is called 'exposure index'. Over one year the sum of all registered 'exposure index' values for an employee must not exceed one. This 'total exposure index' values can also be expressed as an 'effective dose' if its value is multiplied by five rem. While the external body exposures clearly dominate in most departments of EIR, the 'effective doses' in the isotope production department are combinations of different organ doses. 'Low' and 'high risk' groups of employee differ by the relative importance of the four 'effective dose' components: 'low risk group' (effective dose 2 rem): (hand dose, total body dose, incorporation, skin dose). The total value of the 'effective dose' and the relative importance of its components determine the practical radiation protection measures and the appropriate combination and frequency of personnel monitoring for each employee

  14. Results of comparative assessment of US and Foreign Nuclear Power Plant dose experience and dose reduction programs

    International Nuclear Information System (INIS)

    Baum, J.W.; Horan, J.R.; Dionne, B.J.

    1984-01-01

    Based on data evaluated to date it is clear that US plants have higher collective dose equivalents per reactor and per MW-y generated than most other countries. Factors which contribute to low doses include: (1) minimization of cobalt in primary system components exposed to water, (2) careful control of primary system oxygen and pH, (3) good primary system water purity to minimize corrosion product formation, (4) careful plant design, layout and component segration and shielding, (5) management interest and commitment, (6) minimum number of workers and in-depth worker training, (7) use of special tools, and (8) plant standardization. It should be pointed out that reductions in exposure are more difficult and costly in plants already built and operating. The cost-effectiveness of dose reduction efforts at US plants should be carefully evaluated before recommendations are made concerning existing plants

  15. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  16. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  17. Pediatric Obesity: Pharmacokinetic Alterations and Effects on Antimicrobial Dosing.

    Science.gov (United States)

    Natale, Stephanie; Bradley, John; Nguyen, William Huy; Tran, Tri; Ny, Pamela; La, Kirsten; Vivian, Eva; Le, Jennifer

    2017-03-01

    Limited data exist for appropriate drug dosing in obese children. This comprehensive review summarizes pharmacokinetic (PK) alterations that occur with age and obesity, and these effects on antimicrobial dosing. A thorough comparison of different measures of body weight and specific antimicrobial agents including cefazolin, cefepime, ceftazidime, daptomycin, doripenem, gentamicin, linezolid, meropenem, piperacillin-tazobactam, tobramycin, vancomycin, and voriconazole is presented. PubMed (1966-July 2015) and Cochrane Library searches were performed using these key terms: children, pharmacokinetic, obesity, overweight, body mass index, ideal body weight, lean body weight, body composition, and specific antimicrobial drugs. PK studies in obese children and, if necessary, data from adult studies were summarized. Knowledge of PK alterations stemming from physiologic changes that occur with age from the neonate to adolescent, as well as those that result from increased body fat, become an essential first step toward optimizing drug dosing in obese children. Excessive amounts of adipose tissue contribute significantly to body size, total body water content, and organ size and function that may modify drug distribution and clearance. PK studies that evaluated antimicrobial dosing primarily used total (or actual) body weight (TBW) for loading doses and TBW or adjusted body weight for maintenance doses, depending on the drugs' properties and dosing units. PK studies in obese children are imperative to elucidate drug distribution, clearance, and, consequently, the dose required for effective therapy in these children. Future studies should evaluate the effects of both age and obesity on drug dosing because the incidence of obesity is increasing in pediatric patients. © 2017 Pharmacotherapy Publications, Inc.

  18. Radioiodine (I-131) treatment for uncomplicated hyperthyroidism: An assessment of optimal dose and cost-effectiveness

    International Nuclear Information System (INIS)

    Paul, A.K.; Rahman, H.A.; Jahan, N.

    2002-01-01

    Aim: Radioiodine (I-131) is increasingly being considered for the treatment of hyperthyroidism but there is no general agreement for the initial dose. To determine the cost-effectiveness and optimal dose of I-131 to cure disease, we prospectively studied the outcome of radioiodine therapy of 423 patients. Material and Methods: Any of the fixed doses of 6, 8, 10, 12 or 15 mCi of I-131 was administered to the patients relating to thyroid gland size. The individual was excluded from this study who had multinodular goitre and autonomous toxic nodule. Patients were classified as cured if the clinical and biochemical status was either euthyroid or hypothyroid at one year without further treatment by antithyroid drugs or radioiodine. The costs were assessed by analyzing the total cost of care including office visit, laboratory testing, radioiodine treatment, average conveyance and income loss of patient and attendant and thyroxine replacement for a period of 2 years from the day of I-131 administration. Results: The results showed a progressive increase of cure rate from the doses of 6, 8 and 10 mCi by 67%, 76.5% and 85.7% respectively but the cure rate for the doses of 12 and 15 mCi was 87.9% and 88.8% respectively. Cure was directly related to the dose between 6 and 10 mCi but at higher doses the cure rate was increased marginally at the expense of increased total body radiation. There was little variation in total costs, but was higher for low dose-therapy and the cost proportion between the 6 mCi regimen and 10 mCi regimen was 1.04:1. Conclusion: We could conclude that an initial 10 mCi of I-131 may be the optimal dose for curing hyperthyroidism and will also limit the total costs

  19. Hematological toxicity in radioimmunotherapy is predicted both by the computed absorbed whole body dose (cGy) and by the administered dose (mCi)

    International Nuclear Information System (INIS)

    Marquez, Sheri D.; Knox, Susan J.; Trisler, Kirk D.; Goris, Michael L.

    1997-01-01

    -90 anti-CD20 antibody treated group, in which the estimated whole body dose varied (D(cGy)), the decrease in these values was predicted by the linear (zero intercept) equations: DWBC = 0.01158 D(cGy) + 0.05247 D(mCi), DPLAT = 0.1476 D(cGy) + 3.043 D(mCi), and DN=0.0047 D(cGy)+0.0507D(mCi). In the Iodine-131 anti-CD20 antibody treated group, where D(cGy) was constant and equal to 75 cGy, the variation in toxicity was predicted by the linear equation DPLAT = -241 + 5.53 D(mCi), with F=12.184 (p<0.01) and DWBC = -2.62 + 0.0757 D (mCi), with F=3.14 (NS). Conclusion: The results suggest that the total absorbed dose is not an absolute predictor of effect, but in this restricted data set a significant predominant effect of the administered dose on toxicity could not be demonstrated either. The data however do not invalidate the theoretical view that 1) with internal radionuclides a large fraction of the total absorbed dose is delivered at very low dose rates, which may be too low for any appreciable effect, and 2) if variation in the kinetics of the agents lead to an adaptation of the administered dose, the initial dose rate is affected. The therapeutic and toxic effects of RIT are probably a function of both the total dose and the dose rate. Further optimization of this therapy needs to take this into consideration

  20. Population dose commitments due to radioactive releases from nuclear power plant sites in 1981. Volume 3

    International Nuclear Information System (INIS)

    Baker, D.A.; Peloquin, R.A.

    1985-01-01

    Population radiation dose commitments have been estimated from reported radionuclide releases from commercial power reactors operating during 1981. Fifty-year dose commitments from a one-year exposure were calculated from both liquid and atmospheric releases for four population groups (infant, child, teenager and adult) residing between 2 and 80 km from each site. This report tabulates the results of these calculations, showing the dose commitments for both liquid and airborne pathways for each age group and organ. Also included for each site is a histogram showing the fraction of the total population within 2 to 80 km around each site receiving various average dose commitments from the airborne pathways. The total dose commitment from both liquid and airborne pathways from 48 sites ranged from a high of 20 person-rem to a low of 0.008 person-rem with an arithmetic mean of 3 person-rem. The total population dose for all sites was estimated at 160 person-rem for the 98 million people considered at risk

  1. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons.

    Science.gov (United States)

    Ballester, Facundo; Granero, Domingo; Pérez-Calatayud, José; Melhus, Christopher S; Rivard, Mark J

    2009-09-01

    The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (60Co, 137CS, 192Ir, and 169Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta-, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the 192Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Electronic equilibrium within 1% is reached for 60Co, 137CS, 192Ir, and 169Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for 60Co and 192Ir, respectively. Electron emissions become important (i.e., > 0.5%) within 3.3 mm of 60Co and 1.7 mm of 192Ir sources, yet are negligible over all distances for 137Cs and 169Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

  2. Assessment of population external irradiation doses with consideration of Rospotrebnadzor bodies equipment for monitoring of photon radiation dose

    Directory of Open Access Journals (Sweden)

    I. P. Stamat

    2016-01-01

    Full Text Available This paper provides review of equipment and methodology for measurement of photon radiation dose; analysis of possible reasons for considerable deviation between the Russian Federation population annual effective external irradiation doses and the relevant average global value. Data on Rospotrebnadzor bodies dosimetry equipment used for measurement of gamma radiation dose are collected and systematized. Over 60 kinds of dosimeters are used for monitoring of population external irradiation doses. Most of dosimeters used in the country have gas-discharge detectors (Geiger-Mueller counters, minor biochemical annunciators, etc. which have higher total values of own background level and of space radiation response than the modern dosimeters with scintillation detectors. This feature of dosimeters is apparently one of most plausible reasons of a bit overstating assessment of population external irradiation doses. The options for specification of population external irradiation doses assessment are: correction of gamma radiation dose measurement results with consideration of dosimeters own background level and space radiation response, introduction of more up-to-date dosimeters with scintillation detectors, etc. The most promising direction of research in verification of population external irradiation doses assessment is account of dosimetry equipment.

  3. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Willemsen, U.F. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Knesewitsch, P. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Kreisig, T. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Pickardt, C.R. (Dept. of Internal Medicine, Muenchen Univ. (Germany)); Kirsch, C.M. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany))

    1993-11-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  4. Local tumor control and cosmetic outcome following breast-conserving surgery and radiation up to a total dose of 56 Gy without boost in breast cancer patients

    International Nuclear Information System (INIS)

    Bayerl, A.

    2001-01-01

    Purpose: To evaluate overall survival, local tumor control and cosmetic outcome after breast-conserving surgery followed by radiotherapy without boost irradiation. Patients and Methods: In a retrospective study 270 breast cancer patients were treated with breast conserving surgery combined with a homogenous radiation of the tumor bearing breast up to a total dose of 56 Gy without local boost irradiation. Mean follow-up was 48 months. Local tumor control, side effects, cosmetic results and contentment with treatment were assessed using physical examinations and interviews based on a standardized questionnaire. Results: Cause-specific survival at 5 years after treatment was 88.3%, actuarial disease-free survival at 5 years was 76.1%. Within 23 to 78 months after treatment 12 patients suffered from ipsilateral breast recurrence. The actuarial freedom from local recurrence (single tumor manifestation) was 96.8% at 5 years after treatment, 89% at 10 years. The occurrence of local failures was not significantly correlated to tumor size, margins, grading, nodal status, age or lymphangiosis. 15.6% of the patients developed distant metastases. In all patients treatment was performed without interruption. Side effects were predominantly of mild degree, no severe side effects were detected. 73% of physicians and 81% of patients scored their cosmetic outcome as excellent or good. 93% of patients would again decide in favor of this procedure. Whereas, use of adjuvant chemotherapy as well as subcutaneous reconstruction of breast tissue did not significantly affect breast cosmesis, analysis demonstrated impaired cosmetic results related to a larger breast size. Conclusion: The data of this study show that tumor control achieved by breast conserving surgery in combination with a radiation technique up to a total dose of 56 Gy which omits boost irradiation is within the range of literature data. Side effects of the therapy were tolerable. The treatment displayed a good

  5. Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey.

    Science.gov (United States)

    Ekpo, Ernest U; Adejoh, Thomas; Akwo, Judith D; Emeka, Owujekwe C; Modu, Ali A; Abba, Mohammed; Adesina, Kudirat A; Omiyi, David O; Chiegwu, Uche H

    2018-01-29

    To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDI vol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E DLP  =  k × DLP ). The proposed 75th percentile CTDI vol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDI vol comparable to international standards, but considerably higher DLP and effective doses.

  6. Dose-rate effects of low-dropout voltage regulator at various biases

    International Nuclear Information System (INIS)

    Wang Yiyuan; Zheng Yuzhan; Gao Bo; Chen Rui; Fei Wuxiong; Lu Wu; Ren Diyuan

    2010-01-01

    A low-dropout voltage regulator, LM2941, was irradiated by 60 Co γ-rays at various dose rates and biases for investigating the total dose and dose rate effects. The radiation responses show that the key electrical parameters, including its output and dropout voltage, and the maximum output current, are sensitive to total dose and dose rates, and are significantly degraded at low dose rate and zero bias. The integrated circuits damage change with the dose rates and biases, and the dose-rate effects are relative to its electric field. (authors)

  7. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    International Nuclear Information System (INIS)

    Olerud, H.M.

    1998-01-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs

  8. Assessment of patient doses and image quality in X-ray diagnostics in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Olerud, H M

    1998-06-01

    Results from other industrialized countries indicate that the annual number of diagnostic procedures approaches one for every member of the population, and in many cases the individual radiation doses are higher than from any other human activity. Furthermore, the doses to patients for the same type of examination differ widely from place to place, suggesting that there is a considerable potential for dose reduction. This motivated an investigation of the diagnostic use of X-rays in Norway. The trends in the number of X-ray examinations performed annually have been studied. The patient doses (all diagnostics) and image quality (mammography and computed tomography) have been assessed for various radiological procedures. This form the basis for the assessment of total collective effective dose (CED) from X-rays in Norway, and further risk estimates. The radiological practice has then been evaluated according to the radiation protection principles of justification and optimisation. Based on the 1993 examination frequency, the total CED was assessed to 3400 manSv (0.78 mSv/inhabitant). It is estimated that this radiation burden may cause about 100 excess cancer deaths annually. The frequency of CT examination has doubled every fifth year, and did in 1993 represent 7% of the total number of examinations and 30% of the total CED. 129 refs.

  9. The effectiveness of Patient Controlled Analgesia (PCA morphine-ketamine compared to Patient Controlled Analgesia (PCA morphine to reduce total dose of morphine and Visual Analog Scale (VAS in postoperative laparotomy surgery

    Directory of Open Access Journals (Sweden)

    I Gusti Ngurah Mahaalit Aribawa

    2017-05-01

    Full Text Available Background: Laparotomy may cause moderate to severe after surgery pain, thus adequate pain management is needed. The addition of ketamine in patient controlled analgesia (PCA morphine after surgery can be the option. This study aims to evaluate the effectiveness of PCA morphine-ketamine compared to PCA morphine in patient postoperative laparotomy surgery to reduce total dose of morphine requirement and pain intensity evaluated with visual analog scale (VAS. Methods: This study was a double-blind RCT in 58 patients of ASA I and II, age 18-64 years, underwent an elective laparotomy at Sanglah General Hospital. Patients were divided into 2 groups. Group A, got addition of ketamine (1mg/ml in PCA morphine (1mg/ml and patients in group B received morphine (1mg/ml by PCA. Prior to surgical incision both group were given a bolus ketamine 0,15mg/ kg and ketorolac 0,5mg/kg. The total dose of morphine and VAS were measured at 6, 12, and 24 hours postoperatively. Result: Total dose of morphine in the first 24 hours postoperatively at morphine-ketamine group (5,1±0,8mg is lower than morphine only group (6,5±0,9mg p<0,001. VAS (resting 6 and 12 hour postoperative in morphine-ketamine group (13,4±4,8 mm and (10,7±2,6 mm are lower than morphine (17,9±4,1mm p≤0,05 and (12,8±5,3mm p≤0,05. VAS (moving 6, 12, and 24 hour postoperative morphineketamine group (24,8±5,1mm, (18±5,6mm and (9±5,6mm are lower than morphine (28,7±5,2mm p≤0,05, (23,1±6,0mm p≤0,05, and (12,8±5,3mm p≤0,05. Conclusions: Addition of ketamine in PCA morphine for postoperative laparotomy surgery reduces total morphine requirements in 24 hours compared to PCA morphine alone.

  10. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose- effect curve)

    International Nuclear Information System (INIS)

    Al Achkar, W.

    2002-01-01

    In order to draw a dose-effect curve, blood from eight healthy people were studied. Samples were irradiated in tubes with 0.15-2.5 gray of gamma ray.Irradiated and control samples were incubated for cell cultures. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics+ rings and total numbers of breaks were drawn. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  11. COSANI-2, Gamma Doses from SABINE Calculation, Activity from ANISN Flux Calculation

    International Nuclear Information System (INIS)

    Dupont, C.

    1975-01-01

    1 - Nature of physical problem solved: Retrieval of SABINE and/or ANISN results. Calculates in case of SABINE results the individual contributions of capture gamma rays in each region to the total gamma dose and to the total gamma heating may calculate in case of ANISN new activity rates starting from ANISN flux saved on tape and activity cross sections taken on an ANISN binary library tape. The program can draw on a BENSON plotter any of the following quantities: - group flux; - activity rates; - dose rates; - neutron spectra for SABINE; - neutron or gamma direct or adjoint spectra for ANISN; - gamma heating and dose rate for SABINE including individual contributions from each region. Several ANISN and/or SABINE cases can be drawn on the same graph for comparison purposes. 2 - Restrictions on the complexity of the problem: Maximum number of: - tapes containing ANISN and/or SABINE results: 5; - curves per graph: 3; - regions: 40; - points per curve: 500; - energy groups: 200

  12. Latin American dose survey results in mammography studies under IAEA programme: radiological protection of patients in medical exposures (TSA3).

    Science.gov (United States)

    Mora, Patricia; Blanco, Susana; Khoury, Helen; Leyton, Fernando; Cárdenas, Juan; Defaz, María Yolanda; Garay, Fernando; Telón, Flaviano; Aguilar, Juan Garcia; Roas, Norma; Gamarra, Mirtha; Blanco, Daniel; Quintero, Ana Rosa; Nader, Alejandro

    2015-03-01

    Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. The mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For Phase 2, RLA9/067 (2010-11), it was decided to include also digital systems in order to see their impact in future dose optimisation activities. Any new country that joined the project received training in the activities through IAEA expert missions. Twenty-nine new institutions participated (9 analogue and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them D(G) (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO views, respectively: RLA9/057 (analogue) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analogue) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO, respectively, computed radiography systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3 mGy), it can be observed that there is enough room to start

  13. Latin American dose survey results in mammography studies under IAEA programme: radiological protection of patients in medical exposures (TSA3)

    International Nuclear Information System (INIS)

    Mora, Patricia; Blanco, Susana; Khoury, Helen; Leyton, Fernando; Cardenas, Juan; Defaz, Maria Yolanda; Garay, Fernando; Telon, Flaviano; Garcia Aguilar, Juan; Roas, Norma; Gamarra, Mirtha; Blanco, Daniel; Quintero, Ana Rosa; Nader, Alejandro

    2015-01-01

    Latin American countries (Argentina, Brazil, Chile, Costa Rica, Cuba, Ecuador, El Salvador, Guatemala, Mexico, Nicaragua, Paraguay, Uruguay and Venezuela) working under the International Atomic Energy Agency (IAEA) Technical Cooperation Programme: TSA3 Radiological Protection of Patients in Medical Exposures have joined efforts in the optimisation of radiation protection in mammography practice. Through surveys of patient doses, the region has a unique database of diagnostic reference levels for analogue and digital equipment that will direct future optimisation activities towards the early detection of breast cancer among asymptomatic women. During RLA9/057 (2007-09) 24 institutions participated with analogue equipment in a dose survey. Regional training on methodology and measurement equipment was addressed in May 2007. The mean glandular dose (DG) was estimated using the incident kerma in air and relevant conversion coefficients for both projections craneo caudal and mediolateral oblique (CC and MLO). For Phase 2, RLA9/067 (2010-11), it was decided to include also digital systems in order to see their impact in future dose optimisation activities. Any new country that joined the project received training in the activities through IAEA expert missions. Twenty-nine new institutions participated (9 analogue and 20 digital equipment). A total of 2262 patient doses were collected during this study and from them D G (mGy) for both projections were estimated for each institution and country. Regional results (75 percentile in mGy) show for CC and MLO views, respectively: RLA9/057 (analogue) 2.63 and 3.17; RLA/067: 2.57 and 3.15 (analogue) and 2.69 and 2.90 (digital). Regarding only digital equipment for CC and MLO, respectively, computed radiography systems showed 2.59 and 2.78 and direct digital radiography (DDR) systems 2.78 and 3.04. Based on the IAEA Basic Safety Standard (BSS) reference dose (3 mGy), it can be observed that there is enough room to start

  14. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  15. Yield and Chemical Composition of Cucumber Treated by Nitrogen Levels and Doses of Gamma Rays

    International Nuclear Information System (INIS)

    Fath El-Bab, T.Sh.; Abo El-Khier, Om.M.; Abdallah, A.A.G.

    2013-01-01

    Two field experiments were performed at the Atomic Energy Authority, Experimental farm, Inshas, Egypt during 2010 and 2011 summer growing seasons in sandy soil. The experiments were conducted to study the effect of pre-sowing seeds which treated by gamma irradiation with different doses of 0, 2, 4 and 6 Gy. This was in combination with three rates of nitrogen, fertilizer i.e., 30, 60 and 90 Kg N/fed. The experiments were laid out using drip irrigation system. The obtained results indicated that gamma rays doses showed significant differences on cucumber yield per plot or per Fed., increasing doses of gamma rays gradually increased cucumber yield per plot up to highest dose, i.e., (6 Gy). The highest value of total yield was obtained with the highest nitrogen rate (90 Kg N/fed.). Doses of gamma rays significantly increased total soluble solids (T.S.S.), total Carbohydrates, fats, total protein, NPK and Ca of cucumber fruits. Application of 60 Kg N/fed. recorded the highest values of all above mentioned chemical characters except of total protein with 90 kg N/fed. every all dose treatments. The effect of interaction between doses and fertilizer levels on chemical characters were significant therefore, the highest values was found at 4 Gy and 60 Kg N/fed. treatment for protein, fat, nitrogen and potassium contents while the carbohydrate and calcium contents had the highest value with the treatment of 6 Gy and 60 Kg N/fed

  16. Dose rate effect on low-dose hyper-radiosensitivity with cells in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Geon-Min; Kim, Eun-Hee [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Low-dose hyper-radiosensitivity (HRS) is the phenomenon that mammalian cells exhibit higher sensitivity to radiation at low doses (< 0.5 Gy) than expected by the linear-quadratic model. At doses above 0.5Gy, the cellular response is recovered to the level expected by the linear-quadratic model. This transition is called the increased radio-resistance (IRR). HRS was first verified using Chinese hamster V79 cells in vitro by Marples and has been confirmed in studies with other cell lines including human normal and tumor cells. HRS is known to be induced by inactivation of ataxia telangiectasia-mutated (ATM), which plays a key role in repairing DNA damages. Considering the connection between ATM and HRS, one can infer that dose rate may affect cellular response regarding HRS at low doses. In this study, we quantitated the effect of dose rate on HRS by clonogenic assay with normal and tumor cells. The HRS of cells at low dose exposures is a phenomenon already known. In this study, we observed HRS of rat normal diencephalon cells and rat gliosarcoma cells at doses below 1 Gy. In addition, we found that dose rate mattered. HRS occurred at low doses, but only when total dose was delivered at a rate below certain level.

  17. Hanford Dose Overview Program. Comparison of AIRDOS-EPA and Hanford site dose codes

    International Nuclear Information System (INIS)

    Aaberg, R.L.; Napier, B.A.

    1985-11-01

    Radiation dose commitments for persons in the Hanford environs calculated using AIRDOS-EPA were compared with those calculated using a suite of Hanford codes: FOOD, PABLM, DACRIN, and KRONIC. Dose commitments to the population and to the maximally exposed individual (MI) based on annual releases of eight radionuclides from the N-Reactor, were calculated by these codes. Dose commitments from each pathway to the total body, lung, thyroid, and lower large intestine (LLI) are given for the population and MI, respectively. 11 refs., 25 tabs

  18. Total Phenolics and Total Flavonoids Contents and Hypnotic Effect in Mice of Ziziphus mauritiana Lam. Seed Extract

    Directory of Open Access Journals (Sweden)

    Aye Moh Moh San

    2013-01-01

    Full Text Available The seeds of Ziziphus mauritiana Lam. have been traditionally used for treatment of various complications including insomnia and anxiety. They are popularly used as sedative and hypnotic drugs in China, Korea, Myanmar, Vietnam, and other Asian countries. However, no scientific proof on hypnotic activity of Z. mauritiana seeds (ZMS was reported. In this study, the hypnotic activity of 50% ethanolic extract from ZMS was observed on the loss of righting reflex in mice using pentobarbital-induced sleep mice method. The contents of total phenolics and total flavonoids in the extract were also determined. The results showed that the 50% ethanolic extract from ZMS contained total phenolics  mg gallic acid equivalent (GAE/g extract and total flavonoids  mg quercetin equivalent (QE/g extract. Oral administration of the extract at the dose of 200 mg/kg significantly increased the sleeping time in mice intraperitoneally administered with sodium pentobarbital (50 mg/kg body weight. These results supported the traditional use of ZMS for the treatment of insomnia. The seeds of Z. mauritiana should be further developed as an alternative sedative and/or hypnotic product.

  19. Long-term results of total body irradiation in adults with acute lymphoblastic leukemia

    International Nuclear Information System (INIS)

    Marnitz, Simone; Zich, Alexander; Budach, Volker; Jahn, Ulrich; Neumann, Oliver; Martus, Peter; Arnold, Renate

    2014-01-01

    The aim of this chart review of adult patients treated for acute lymphoblastic leukemia (ALL) with total body irradiation (TBI) was to evaluate early and late toxicity and long-term outcome. A total of 110 adult patients (34 ± 12 years) with ALL underwent TBI (6 fractions of 2 Gy for a total of 12 Gy) as a part of the treatment regimen before transplantation. Treatment-related toxicity, mortality, and hematologic outcome are reported. Mean follow-up was 70 months. The 2- and 5-year leukemia-free survival rates were 78 and 72 %, respectively. In all, 29 % (32/110) patients suffered from medullary recurrence after a median time of 7 months. Gender was the only statistically significant prognostic factor in terms of overall survival in favor of female patients. Treatment-related mortality and overall survival after 2 and 5 years were 16 and 22 %, and 60 and 52.7 %, respectively. The most frequent late reaction wascGVHD of the skin (n = 33, 30 %). In addition, 15.5 % (17/110 patients) suffered pulmonary symptoms, and 6 patients developed lung fibrosis. Eyes were frequently affected by the radiation (31/110 = 28 %); 12 of 110 patients (11 %) presented with symptoms from osteoporosis, 5 of 110 patients (4.5 %) developed hypothyreosis and 2 patients diabetes mellitus. Of the male patients, 11 % reported erectile dysfunction or loss of libido, while 2 of 36 women reported menopausal syndrome at the mean time of 28 months after treatment with requirement for substitution. No women became pregnant after treatment. No acute or late cardiac toxicities were documented in our patients. No secondary malignancies were documented. Although hematologic outcome was in the upper range of that reported in the literature, treatment-related mortality (TRM) and medullary recurrences remain a challenge. Sophisticated radiation techniques allow for decreasing toxicity to certain organs and/or dose escalation to the bone marrow in highly selected patients in order to improve therapeutic

  20. Can results from animal studies be used to estimate dose or low dose effects in humans

    International Nuclear Information System (INIS)

    Thomas, J.M.; Eberhardt, L.L.

    1981-01-01

    A method has been devised to extrapolate biological equilibrium levels between animal species and subsequently to humans. Our initial premise was based on the observation that radionuclide retention is normally a function of metabolism so that direct or indirect measures could be described by a power law based on body weights of test animal species. However, we found that such interspecies comparisons ought to be based on the coefficient of the power equation rather than on the exponential parameter. The method is illustrated using retention data obtained from five non-ruminant species (including humans) that were fed radionuclides with different properties. It appears that biological equilibrium level for radionuclides in man can be estimated using data from mice, rats, and dogs. The need to extrapolate low-dose effects data obtained from small animals (usually rodents) to humans is not unique to radiation dosimetry or radiation protection problems. Therefore, some quantitative problems connected with estimating low-dose effects from other disciplines have been reviewed, both because of the concern about effects induced by the radionuclide moiety of a radiopharmaceutical and those of the nonradioactive component. The possibility of extrapolating low-dose effects calculated from animal studies to human is discussed