WorldWideScience

Sample records for total contact area

  1. Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis.

    Science.gov (United States)

    Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio

    2017-11-25

    Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.

  2. Thigh-calf contact parameters for six high knee flexion postures: Onset, maximum angle, total force, contact area, and center of force.

    Science.gov (United States)

    Kingston, David C; Acker, Stacey M

    2018-01-23

    In high knee flexion, contact between the posterior thigh and calf is expected to decrease forces on tibiofemoral contact surfaces, therefore, thigh-calf contact needs to be thoroughly characterized to model its effect. This study measured knee angles and intersegmental contact parameters in fifty-eight young healthy participants for six common high flexion postures using motion tracking and a pressure sensor attached to the right thigh. Additionally, we introduced and assessed the reliability of a method for reducing noise in pressure sensor output. Five repetitions of two squatting, two kneeling, and two unilateral kneeling movements were completed. Interactions of posture by sex occurred for thigh-calf and heel-gluteal center of force, and thigh-calf contact area. Center of force in thigh-calf regions was farther from the knee joint center in females, compared to males, during unilateral kneeling (82 and 67 mm respectively) with an inverted relationship in the heel-gluteal region (331 and 345 mm respectively), although caution is advised when generalizing these findings from a young, relatively fit sample to a population level. Contact area was larger in females when compared to males (mean of 155.61 and 137.33 cm 2 across postures). A posture main effect was observed in contact force and sex main effects were present in onset and max angle. Males had earlier onset (121.0°) and lower max angle (147.4°) with onset and max angles having a range between movements of 8° and 3° respectively. There was a substantial total force difference of 139 N between the largest and smallest activity means. Force parameters measured in this study suggest that knee joint contact models need to incorporate activity-specific parameters when estimating loading. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  4. Relationship between the real contact area and contact force in pre-sliding regime

    International Nuclear Information System (INIS)

    Song Baojiang; Yan Shaoze

    2017-01-01

    The pre-sliding regime is typically neglected in the dynamic modelling of mechanical systems. However, the change in contact state caused by static friction may decrease positional accuracy and control precision. To investigate the relationship between contact status and contact force in pre-sliding friction, an optical experimental method is presented in this paper. With this method, the real contact state at the interface of a transparent material can be observed based on the total reflection principle of light by using an image processing technique. A novel setup, which includes a pair of rectangular trapezoidal blocks, is proposed to solve the challenging issue of accurately applying different tangential and normal forces to the contact interface. The improved Otsu’s method is used for measurement. Through an experimental study performed on polymethyl methacrylate (PMMA), the quantity of contact asperities is proven to be the dominant factor that affects the real contact area. The relationship between the real contact area and the contact force in the pre-sliding regime is studied, and the distribution of static friction at the contact interface is qualitatively discussed. New phenomena in which the real contact area expands along with increasing static friction are identified. The aforementioned relationship is approximately linear at the contact interface under a constant normal pressure, and the distribution of friction stress decreases from the leading edge to the trailing edge. (paper)

  5. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Total contact cast for neuropathic diabetic foot ulcers

    International Nuclear Information System (INIS)

    Ali, R.; Yaqoob, M.Y.

    2008-01-01

    To determine the outcome of diabetic neuropathic foot ulcers treated with Total Contact Cast (TCC) in terms of percentage of ulcers healed and time to heal. The study included diabetic patients with non-ischemic neuropathic foot ulcers of upto grade 2 of Wagner's classification. Ulcers were debrided off necrotic tissues and Total Contact Cast (TCC) was applied. TCC was renewed every 2 weeks till healing. Cases were labeled as cast failure when there was no reduction in wound size in 4 consecutive weeks or worsening to a higher grade. Main outcome measures were the percentage of ulcers healed and time to heal in the cast. Thirty four (87.17%) patients were males and 5(12.82%) were females. The mean age was 62 +- 13.05 years. All patients had NIDDM. Out of the 52 ulcers, 41(78.84%) healed with TCC in an average 2 casts duration (mean 32 days). There were 11(21.15%) cast failure. Majority (63.63%) of cast failure ulcers were located on pressure bearing area of heel. Most (90%) of the ulcers on forefoot and midsole region healed with TCC (p<0.001). Longer ulcer duration (mean 57.45 +- 29.64 days) significantly reduced ulcer healing (p<0.001). Total contact cast was an effective treatment modality for neuropathic diabetic foot ulcers of Wagner's grade 2, located on forefoot and midsole region. (author)

  7. Molecular dynamics study of contact mechanics: contact area and interfacial separation from small to full contact

    OpenAIRE

    Yang, C.; Persson, B. N. J.

    2007-01-01

    We report a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. We study the contact area and the interfacial separation from small contact (low load) to full contact (high load). For small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For high load the contact area approaches to the nominal contact area (i.e., complete contact), and the i...

  8. Totally Contact Umbilical Lightlike Hypersurfaces of Indefinite -Manifolds

    Directory of Open Access Journals (Sweden)

    Rachna Rani

    2013-01-01

    Full Text Available We study totally contact umbilical lightlike hypersurfaces of indefinite -manifolds and prove the nonexistence of totally contact umbilical lightlike hypersurface in indefinite -space form.

  9. Can foot anthropometric measurements predict dynamic plantar surface contact area?

    Directory of Open Access Journals (Sweden)

    Collins Natalie

    2009-10-01

    Full Text Available Abstract Background Previous studies have suggested that increased plantar surface area, associated with pes planus, is a risk factor for the development of lower extremity overuse injuries. The intent of this study was to determine if a single or combination of foot anthropometric measures could be used to predict plantar surface area. Methods Six foot measurements were collected on 155 subjects (97 females, 58 males, mean age 24.5 ± 3.5 years. The measurements as well as one ratio were entered into a stepwise regression analysis to determine the optimal set of measurements associated with total plantar contact area either including or excluding the toe region. The predicted values were used to calculate plantar surface area and were compared to the actual values obtained dynamically using a pressure sensor platform. Results A three variable model was found to describe the relationship between the foot measures/ratio and total plantar contact area (R2 = 0.77, p R2 = 0.76, p Conclusion The results of this study indicate that the clinician can use a combination of simple, reliable, and time efficient foot anthropometric measurements to explain over 75% of the plantar surface contact area, either including or excluding the toe region.

  10. Solar Cels With Reduced Contact Areas

    Science.gov (United States)

    Daud, T.; Crotty, G. T.; Kachare, A. H.; Lewis, J. T.

    1987-01-01

    Efficiency of silicon solar cells increased about 20 percent using smaller metal-contact area on silicon at front and back of each cell. Reduction in contact area reduces surface recombination velocity under contact and thus reduces reverse saturation current and increases opencircuit voltage..

  11. An analytical method for computing atomic contact areas in biomolecules.

    Science.gov (United States)

    Mach, Paul; Koehl, Patrice

    2013-01-15

    We propose a new analytical method for detecting and computing contacts between atoms in biomolecules. It is based on the alpha shape theory and proceeds in three steps. First, we compute the weighted Delaunay triangulation of the union of spheres representing the molecule. In the second step, the Delaunay complex is filtered to derive the dual complex. Finally, contacts between spheres are collected. In this approach, two atoms i and j are defined to be in contact if their centers are connected by an edge in the dual complex. The contact areas between atom i and its neighbors are computed based on the caps formed by these neighbors on the surface of i; the total area of all these caps is partitioned according to their spherical Laguerre Voronoi diagram on the surface of i. This method is analytical and its implementation in a new program BallContact is fast and robust. We have used BallContact to study contacts in a database of 1551 high resolution protein structures. We show that with this new definition of atomic contacts, we generate realistic representations of the environments of atoms and residues within a protein. In particular, we establish the importance of nonpolar contact areas that complement the information represented by the accessible surface areas. This new method bears similarity to the tessellation methods used to quantify atomic volumes and contacts, with the advantage that it does not require the presence of explicit solvent molecules if the surface of the protein is to be considered. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.

  12. [Determination of joint contact area using MRI].

    Science.gov (United States)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  13. Determination of joint contact area using MRI

    International Nuclear Information System (INIS)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-01-01

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo. (author)

  14. Friction and universal contact area law for randomly rough viscoelastic contacts.

    Science.gov (United States)

    Scaraggi, M; Persson, B N J

    2015-03-18

    We present accurate numerical results for the friction force and the contact area for a viscoelastic solid (rubber) in sliding contact with hard, randomly rough substrates. The rough surfaces are self-affine fractal with roughness over several decades in length scales. We calculate the contribution to the friction from the pulsating deformations induced by the substrate asperities. We also calculate how the area of real contact, A(v, p), depends on the sliding speed v and on the nominal contact pressure p, and we show how the contact area for any sliding speed can be obtained from a universal master curve A(p). The numerical results are found to be in good agreement with the predictions of an analytical contact mechanics theory.

  15. Changes of contact pressure and area in patellofemoral joint after different meniscectomies.

    Science.gov (United States)

    Bai, Bo; Shun, Hui; Yin, Zhi Xun; Liao, Zhuang-Wen; Chen, Ni

    2012-05-01

    We investigated the contact pressure and area of the patellofemoral joint both before and after different meniscectomies to provide a biomechanical basis for selecting meniscectomy and its clinical application for meniscus injuries. Six fresh cadaveric knees were used in the study. Using Staubli robots and an ultra-low-min-type pressure-sensitive tablet, changes in contact area and stress in the patellofemoral joint were measured at various flexion angles following different parts and degrees of meniscectomy. The patellofemoral contact area enlarged with the increase of knee flexion angle. From the values obtained from contact areas and average contact pressure of the patellofemoral joint, we found no significant difference between partial meniscectomy and intact knees, but a significant difference was found between total meniscectomy and intact knees. The contact area after lateral meniscectomy was statistically less than that of intact knees. The mean patellofemoral contact pressure after lateral meniscectomy was larger than in intact knees at each angle of flexion. No significant difference in contact area was observed between intact knees and medial meniscectomy. The average patellofemoral contact pressure after medial meniscectomy was larger than in intact knees from 0° ~ 30° of knee flexion, and no significant differences were found between intact knees and medial meniscectomy while knee bending from 60° to 90°. Different meniscectomies result in high contact pressure or disordered distribution of contact pressure, which may be the cause of postoperative patellofemoral degenerative arthrosis.

  16. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  17. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  18. Contact area measurements on structured surfaces

    DEFF Research Database (Denmark)

    Kücükyildiz, Ömer Can; Jensen, Sebastian Hoppe Nesgaard; De Chiffre, Leonardo

    In connection with the use of brass specimens featuring structured surfaces in a tribology test, an algorithm was developed for automatic measurement of the contact area by optical means.......In connection with the use of brass specimens featuring structured surfaces in a tribology test, an algorithm was developed for automatic measurement of the contact area by optical means....

  19. Tibiofemoral contact stress and stress distribution evaluation of total knee arthroplasties.

    Science.gov (United States)

    Szivek, J A; Cutignola, L; Volz, R G

    1995-08-01

    The Fuji film (Itochu, Los Angeles, CA) area analysis technique demonstrates that a more accurate assessment of tibiofemoral contact stresses is possible when the film is used at 37 degrees C and at the upper end of its sensitivity range (in this case, a 2,000-N load). An AMK with a regular and Hylamer-M insert (DePuy, Warsaw, IN), an MG II (Zimmer, Warsaw, IN), an Omnifit (Osteonics, Allendale, NJ), an Ortholoc III (Dow Corning Wright, Midland, MI), a PCA II (Howmedica, Rutherford, NJ), and a PFC (Johnson & Johnson Orthopaedics, Raynham, MA) had average contact stresses that varied only 12% at 60 degrees flexion. At 0 degrees, 15 degrees and 60 degrees flexion, stresses ranged from 13 to 25 MPa. Contact area distribution ratios, which were smaller at 37 degrees C than at 24 degrees C, provide a quantitative means of grouping implants according to the shape of the tibiofemoral contact area. The Omnifit, MG II, PCA II, and PFC had small ratios (symmetric areas). The AMK and Ortholoc III had large ratios (asymmetric contact areas). If the impression is reflective of wear, it would be expected to be focal in knees with small ratios and contact areas, and uniform in knees with large ratios and contact areas, whereas large ratios and small areas would imply a linear wear pattern. Calibrated electrical resistance contact stress measurements indicated that the Fuji film measurements underestimated the magnitude of contact stresses. They also provided a means of quantifying the rate of area increase during initial loading of the knees, with the highest area increase noted for the knee with the roughest insert (Ortholoc III) and the lowest area increase for the knee with the smoothest insert (PCA II).

  20. Reducing contact resistance in graphene devices through contact area patterning.

    Science.gov (United States)

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  1. Deformation processes within wheel-rail adhesion in contact area

    Science.gov (United States)

    Albagachiev, A. Yu; Keropyan, A. M.

    2018-03-01

    The study of working surface deformation during interaction of open-pit locomotive tires allowed defining outstanding features of phenomena occurring in the contact area of interacting surfaces. It was found that processes typical for plastic saturated contact occur in the area of wheel-rail interaction of industrial railway transport. In case of plastic deformation exposed to heavy loads typical for open-pit locomotives, upon all rough surfaces of the contour contact area being fully deformed, the frame on which they are found is exposed to plastic deformation. Plastic deformation of roughness within the contact area of interacting surfaces leads to the increase in the actual area of their contact and, therefore, increases the towing capacity of mining machines. Finally, the available data on deformation characteristics with regard to processes occurring in the contact area of wheel-rail interaction will allow making theoretical forecasts on the expected design value of friction coefficient and, therefore, the towing capacity of open-pit locomotives.

  2. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  3. Plastic deformation and contact area of an elastic-plastic contact of ellipsoid bodies after unloading

    NARCIS (Netherlands)

    Jamari, Jamari; Schipper, Dirk J.

    2007-01-01

    This paper presents theoretical and experimental results of the residual or plastic deformation and the plastic contact area of an elastic–plastic contact of ellipsoid bodies after unloading. There are three regime responses of the deformation and contact area: elastic, elastic–plastic and fully

  4. The relationship between area deprivation and contact with community intellectual disability psychiatry.

    Science.gov (United States)

    Nicholson, L; Hotchin, H

    2015-05-01

    People with intellectual disabilities (ID) have high rates of psychiatric illness and are known to live in more deprived areas than the general population. This study investigated the relationship between area deprivation and contact with ID psychiatry. Psychiatric case notes and electronic records were used to identify all patients who had face-to-face contact with community ID psychiatric services over 1 year in the North East Community Health Partnership of Greater Glasgow and Clyde (estimated population 177,867). The Scottish Index of Multiple Deprivation (SIMD) were determined for the patient sample and for the general population living in the same area. Between 1 June 2012 and 1 June 2013, 184 patients were seen by ID psychiatry over a total of 553 contacts, with valid SIMD data for 179 patients and 543 contacts. Fifty-two per cent of patients (n = 93) lived in the most deprived SIMD decile, and 90.5% (n = 152) in the lowest 5 deciles. Compared with the general population, there were significantly more patients than expected living in the most deprived decile (Fisher's Exact test, P = 0.009) and in the most deprived 5 deciles (Fisher's Exact test, P = 0.001). The median number of contacts was 2 (interquartile range = 1-3). There was no significant association between the number of contacts and SIMD decile. Forty-eight point one per cent (n = 261) of all contacts were with patients living in the most deprived decile and 88.6% (n = 481) in the most deprived 5 deciles. This was significantly more than expected compared with general population data (Fisher's Exact test, P = 0.008 and Fisher's Exact test, P ≤ 0.001). In the area under study, contact with ID psychiatry was greater in more deprived areas. Given the high psychiatric morbidity of people with ID, if services do not adjust for deprivation, this may lead to further discrimination in an already disadvantaged population. © 2014 MENCAP and International Association of the Scientific Study of Intellectual

  5. Comparison of plantar pressures and contact area between normal and cavus foot.

    Science.gov (United States)

    Fernández-Seguín, Lourdes M; Diaz Mancha, Juan Antonio; Sánchez Rodríguez, Raquel; Escamilla Martínez, Elena; Gómez Martín, Beatriz; Ramos Ortega, Javier

    2014-02-01

    In pes cavus, the medial longitudinal arch elevation reduces the contact surface area and consequently increases the corresponding plantar pressure measurements. This poor distribution of loads may produce associated pathology and pain in this or other areas of the body. Normal reference values need to be established in order to determine which patterns are prone to pathology. To compare the plantar pressures and weight-bearing surface in a population with pes cavus to a population with neutral feet. The sample comprised 68 adults, 34 with pes cavus and 34 with neutral feet. The Footscan USB Gait Clinical System(®) was used as a platform to measure the total contact area and plantar pressure under the forefoot, midfoot, hindfoot, each metatarsal head, and the overall metatarsal area. A statistical analysis of the data was performed using Student's t-test for independent samples. The pes cavus subjects showed a significant reduction in their weight-bearing area [neutral feet: 165.04 ( ± 20.68) cm(2); pes cavus: 118.26 ( ± 30.31) cm(2); p contact surface and the load under the first toe. A significant increase is present in the load under the metatarsal areas, but the relative distribution of this load is similar in both groups. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Determination of the nano-scaled contact area of staphylococcal cells.

    Science.gov (United States)

    Spengler, Christian; Thewes, Nicolas; Jung, Philipp; Bischoff, Markus; Jacobs, Karin

    2017-07-20

    Bacterial adhesion is a crucial step during the development of infections as well as the formation of biofilms. Hence, fundamental research of bacterial adhesion mechanisms is of utmost importance. So far, less is known about the size of the contact area between bacterial cells and a surface. This gap will be filled by this study using a single-cell force spectroscopy-based method to investigate the contact area between a single bacterial cell of Staphylococcus aureus and a solid substrate. The technique relies on the strong influence of the hydrophobic interaction on bacterial adhesion: by incrementally crossing a very sharp hydrophobic/hydrophilic interface while performing force-distance curves with a single bacterial probe, the bacterial contact area can be determined. Assuming circular contact areas, their radii - determined in our experiments - are in the range from tens of nanometers to a few hundred nanometers. The contact area can be slightly enlarged by a larger load force, yet does not resemble a Hertzian contact, rather, the enlargement is a property of the individual bacterial cell. Additionally, Staphylococcus carnosus has been probed, which is less adherent than S. aureus, yet both bacteria exhibit a similar contact area size. This corroborates the notion that the adhesive strength of bacteria is not a matter of contact area, but rather a matter of which and how many molecules of the bacterial species' cell wall form the contact. Moreover, our method of determining the contact area can be applied to other microorganisms and the results might also be useful for studies using nanoparticles covered with soft, macromolecular coatings.

  7. Automatic quantification of tibio-femoral contact area and congruity

    DEFF Research Database (Denmark)

    Tummala, Sudhakar; Nielsen, Mads; Lillholm, Martin

    2012-01-01

    We present methods to quantify the medial tibio- femoral (MTF) joint contact area (CA) and congruity index (CI) from low-field magnetic resonance imaging (MRI). Firstly, based on the segmented MTF cartilage compartments, we computed the contact area using the Euclidian distance transformation....... The CA was defined as the area of the tibial superior surface and the femoral inferior surface that are less than a voxel width apart. Furthermore, the CI is computed point-by-point by assessing the first- and second-order general surface features over the contact area. Mathematically, it is the inverse...

  8. Effect of time derivative of contact area on dynamic friction

    OpenAIRE

    Arakawa, Kazuo

    2015-01-01

    This study investigated dynamic friction during oblique impact of a golf ball by evaluating the ball’s angular velocity, contact force, and the contact area between the ball and target. The effect of the contact area on the angular velocities was evaluated, and the results indicated that the contact area plays an important role in dynamic friction. In this study, the dynamic friction force F was given by F= μN+μη.dA/dt, where μ is the coefficient of friction, N is the contact force, dA/dt is ...

  9. Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.

    Science.gov (United States)

    Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D

    2011-10-01

    To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.

  10. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    Science.gov (United States)

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  11. Optimizing pressurized contact area in rotator cuff repair: the diamondback repair.

    Science.gov (United States)

    Burkhart, Stephen S; Denard, Patrick J; Obopilwe, Elifho; Mazzocca, Augustus D

    2012-02-01

    The purpose of this study was to compare tendon-bone footprint contact area over time under physiologic loads for 4 different rotator cuff repair techniques: single row (SR), triangle double row (DR), chain-link double row (CL), and diamondback double row (DBK). A supraspinatus tear was created in 28 human cadavers. Tears were fixed with 1 of 4 constructs: SR, DR, CL, or DBK. Immediate post-repair measurements of pressurized contact area were taken in neutral rotation and 0° of abduction. After a static tensile load, pressurized contact area was observed over a 160-minute period after repair. Cyclic loading was then performed. The DBK repair had the highest pressurized contact area initially, as well as the highest pressurized contact area and lowest percentage decrease in pressurized contact area after 160 minutes of testing. The DBK repair had significantly larger initial pressurized contact than CL (P = .003) and SR (P = .004) but not DR (P = .06). The DBK technique was the only technique that produced a pressurized contact area that exceeded the native footprint both at initial repair (P = .01) and after 160 minutes of testing (P = .01). DBK had a significantly larger mean pressurized contact area than all the repairs after 160 minutes of testing (P = .01). DBK had a significantly larger post-cyclic loading pressurized contact area than CL (P = .01) and SR (P = .004) but not DR (P = .07). This study showed that a diamondback repair (a modification of the transosseous repair) can significantly increase the rotator cuff pressurized contact area in comparison with other standard rotator cuff repair constructs when there is sufficient tendon mobility to perform a double-row repair without excessive tension on the repair site. The persistent pressurized contact area of a DBK repair may be desirable to enhance healing potential when there is sufficient tendon mobility to perform a double-row repair, particularly for large or massive rotator cuff tears where it is

  12. Effect of load, area of contact, and contact stress on the tribological properties of polyimide bonded graphite fluoride films

    Science.gov (United States)

    Fusaro, R. L.

    1981-01-01

    A pin-on-disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide-bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically-tipped riders. Different projected contact stresses were obtained by applying loads of 2.5-to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build-up of thick rider transfer films.

  13. Effect of load, area of contact, and contact stress on the wear mechanisms of a bonded solid lubricant film

    Science.gov (United States)

    Fusaro, R. L.

    1980-01-01

    A pin on disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically tipped riders. Different projected contact stresses were obtained by applying loads of 2.5- to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build up of thick rider transfer films.

  14. A novel algorithm for determining contact area between a respirator and a headform.

    Science.gov (United States)

    Lei, Zhipeng; Yang, James; Zhuang, Ziqing

    2014-01-01

    The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P contact area dimensions (P contact area, while the large and small headforms produced the smallest.

  15. Transmission of vibration through gloves: effects of contact area.

    Science.gov (United States)

    Md Rezali, Khairil Anas; Griffin, Michael J

    2017-01-01

    For three samples of material (12.5, 25.0 and 37.5 mm diameter) from each of three gloves, the dynamic stiffnesses and the vibration transmissibilities of the materials (to both the palm of the hand and the thenar eminence) were measured at frequencies from 10 to 300 Hz. Additional measurements showed the apparent masses of the hand at the palm and the thenar eminence were independent of contact area at frequencies less than about 40 Hz, but increased with increasing area at higher frequencies. The stiffness and damping of the glove materials increased with increasing area. These changes caused material transmissibilities to the hand to increase with increasing area. It is concluded that the size of the area of contact has a large influence on the transmission of vibration through a glove to the hand. The area of contact should be well-defined and controlled when evaluating the transmission of vibration through gloves. Practitioner Summary: The transmission of vibration through gloves depends on both the dynamic stiffness of glove material and the dynamic response of the hand. Both of these depend on the size of the contact area between a glove material and the hand, which should be taken into account when assessing glove transmissibility.

  16. Experimental and numerical investigation of contact-area-limited doping for top-contact pentacene thin-film transistors with Schottky contact.

    Science.gov (United States)

    Noda, Kei; Wada, Yasuo; Toyabe, Toru

    2015-10-28

    Effects of contact-area-limited doping for pentacene thin-film transistors with a bottom-gate, top-contact configuration were investigated. The increase in the drain current and the effective field-effect mobility was achieved by preparing hole-doped layers underneath the gold contact electrodes by coevaporation of pentacene and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ), confirmed by using a thin-film organic transistor advanced simulator (TOTAS) incorporating Schottky contact with a thermionic field emission (TFE) model. Although the simulated electrical characteristics fit the experimental results well only in the linear regime of the transistor operation, the barrier height for hole injection and the gate-voltage-dependent hole mobility in the pentacene transistors were evaluated with the aid of the device simulation. This experimental data analysis with the simulation indicates that the highly-doped semiconducting layers prepared in the contact regions can enhance the charge carrier injection into the active semiconductor layer and concurrent trap filling in the transistor channel, caused by the mitigation of a Schottky energy barrier. This study suggests that both the contact-area-limited doping and the device simulation dealing with Schottky contact are indispensable in designing and developing high-performance organic thin-film transistors.

  17. Development of a computational technique to measure cartilage contact area.

    Science.gov (United States)

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.

    Science.gov (United States)

    Armstrong, D G; Liswood, P J; Todd, W F

    1995-12-01

    The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.

  19. Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow.

    Science.gov (United States)

    Bellato, Enrico; Fitzsimmons, James S; Kim, Youngbok; Bachman, Daniel R; Berglund, Lawrence J; Hooke, Alexander W; O'Driscoll, Shawn W

    2018-03-21

    Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p contact area increased from 80 ± 8 mm to 150 ± 58 mm (p contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.

  20. Analysis of in vitro and in vivo function of total knee replacements using dynamic contact models

    Science.gov (United States)

    Zhao, Dong

    Despite the high incidence of osteoarthritis in human knee joint, its causes remain unknown. Total knee replacement (TKR) has been shown clinically to be effective in restoring the knee function. However, wear of ultra-high molecular weight polyethylene has limited the longevity of TKRs. To address these important issues, it is necessary to investigate the in vitro and in vivo function of total knee replacements using dynamic contact models. A multibody dynamic model of an AMTI knee simulator was developed. Incorporating a wear prediction model into the contact model based on elastic foundation theory enables the contact surface to take into account creep and wear during the dynamic simulation. Comparisons of the predicted damage depth, area, and volume lost with worn retrievals from a physical machine were made to validate the model. In vivo tibial force distributions during dynamic and high flexion activities were investigated using the dynamic contact model. In vivo medial and lateral contact forces experienced by a well-aligned instrumented knee implant, as well as upper and lower bounds on contact pressures for a variety of activities were studied. For all activities, the predicted medial and lateral contact forces were insensitive to the selected material model. For this patient, the load split during the mid-stance phase of gait and during stair is more equal than anticipated. The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. In vivo data collected from a subject with an instrumented knee implant were analyzed to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe out) while instrumented implant, video motion, and ground reaction data were simultaneously collected. The high correlation coefficient

  1. External Validation of Contact Surface Area as a Predictor of Postoperative Renal Function in Patients Undergoing Partial Nephrectomy.

    Science.gov (United States)

    Haifler, Miki; Ristau, Benjamin T; Higgins, Andrew M; Smaldone, Marc C; Kutikov, Alexander; Zisman, Amnon; Uzzo, Robert G

    2017-09-20

    We sought to externally validate a mathematical formula for tumor contact surface area as a predictor of postoperative renal function in patients undergoing partial nephrectomy for renal cell carcinoma. We queried a prospectively maintained kidney cancer database for patients who underwent partial nephrectomy between 2014 and 2016. Contact surface area was calculated using data obtained from preoperative cross-sectional imaging. The correlation between contact surface area and perioperative variables was examined. The correlation between postoperative renal functional outcomes, contact surface area and the R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to collecting system or sinus, anterior/posterior, location relative to polar lines and tumor touches main renal artery or vein) nephrometry score was also assessed. A total of 257 patients who underwent partial nephrectomy had sufficient data to enter the study. Median contact surface area was 14.5 cm 2 (IQR 6.2-36) and the median nephrometry score was 9 (IQR 7-10). Spearman correlation analysis showed that contact surface area correlated with estimated blood loss (r s = 0.42, p contact surface area and nephrometry score were independent predictors of the absolute change in the estimated glomerular filtration rate (each p contact surface area was a better predictor of a greater than 20% postoperative decline in the estimated glomerular filtration rate compared with the nephrometry score (AUC 0.94 vs 0.80). Contact surface area correlated with the change in postoperative renal function after partial nephrectomy. It can be used in conjunction with the nephrometry score to counsel patients about the risk of renal functional decline after partial nephrectomy. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. A measurement method for distinguishing the real contact area of rough surfaces of transparent solids using improved Otsu technique

    International Nuclear Information System (INIS)

    Song Bao-Jiang; Yan Shao-Ze; Xiang Wu-Wei-Kai

    2015-01-01

    An experimental method of measuring the real contact area of transparent blocks based on the principle of total internal reflection is presented, intending to support the investigation of friction characteristics, heat conduction, and energy dissipation at the contact interface. A laser sheet illuminates the contact interface, and the transmitted laser sheet is projected onto a screen. Then the contact information is acquired from the screen by a camera. An improved Otsu method is proposed to process the data of experimental images. It can compute the threshold of the overall image and filter out all the pixels one by one. Through analyzing the experimental results, we describe the relationship between the real contact area and the positive pressure during a continuous loading process, at different loading rates, with the polymethyl methacrylate (PMMA) material. A hysteresis phenomenon in the relationship between the real contact area and the positive pressure is found and explained. (paper)

  3. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  4. Effect of hoof angle on joint contact area in the equine metacarpophalangeal joint following simulated impact loading ex vivo.

    Science.gov (United States)

    McCarty, C A; Thomason, J J; Gordon, K; Hurtig, M; Bignell, W

    2015-11-01

    To add to the existing data on impact loading of the metacarpophalangeal (MCP) joint as a precursor to assessing the potential role of impact in joint disease. To examine the effect of impact loading on contact areas of the first phalanx (P1) and proximal sesamoids (PS) with the third metacarpal (McIII) under 3 hoof-strike conditions (toe-first, flat, heel-first). Randomised, repeated controlled experiment using cadaver material. Eight cadaver limbs were subjected to randomised, repeated controlled trials where the hoof was struck by a pendulum impact machine (impact velocity 3.55 m/s) under 3 strike conditions. Data from pressure sensitive film placed over medial and lateral McIII condyles and lateromedially across the dorsal aspect of McIII were quantified: total areas of P1 and PS contact (cm(2) ) at maximum recorded pressure; centroid locations of contact areas relative to the sagittal ridge (cm) and transverse ridge (cm) and dispersion of pixels (cm(4) ) for each McIII condyle (medial/lateral). The effect of the strike conditions on each variable were statistically tested using repeated-measures ANOVA (α = 0.05). Contact area between P1 and McIII condyles fell in well-defined areas bounded by the sagittal and transverse ridge, contact areas from PS were smaller and widely dispersed across McIII palmar border. Ratio of contact area of P1 to PS was 2.83 (Pcontact area (P>0.54) CONCLUSIONS: Contact at impact (primarily from P1 and distally situated on McIII), contrasts with contact areas at midstance from both P1 and PS, symmetrically placed. Under impact, the greatest contact area was on the dorsal aspect of the medial condyle and coincides with the area subjected to the greatest increase in subchondral bone stiffening in joint disease. © 2014 EVJ Ltd.

  5. Effect of 3D fractal dimension on contact area and asperity interactions in elastoplastic contact

    Directory of Open Access Journals (Sweden)

    Abdeljalil Jourani

    2016-05-01

    Full Text Available Few models are devoted to investigate the effect of 3D fractal dimension Ds on contact area and asperity interactions. These models used statistical approaches or two-dimensional deterministic simulations without considering the asperity interactions and elastic–plastic transition regime. In this study, a complete 3D deterministic model is adopted to simulate the contact between fractal surfaces which are generated using a modified two-variable Weierstrass–Mandelbrot function. This model incorporates the asperity interactions and considers the different deformation modes of surface asperities which range from entirely elastic through elastic-plastic to entirely plastic contact. The simulations reveal that the elastoplastic model is more appropriate to calculate the contact area ratio and pressure field. It is also shown that the influence of the asperity interactions cannot be neglected, especially at lower fractal dimension Ds and higher load.

  6. Influence of occlusal contact area on cusp defection and stress distribution.

    Science.gov (United States)

    Costa, Anna Karina Figueiredo; Xavier, Thaty Aparecida; Paes-Junior, Tarcisio José Arruda; Andreatta-Filho, Oswaldo Daniel; Borges, Alexandre Luiz Souto

    2014-11-01

    The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental

  7. Total contact cast wall load in patients with a plantar forefoot ulcer and diabetes.

    Science.gov (United States)

    Begg, Lindy; McLaughlin, Patrick; Vicaretti, Mauro; Fletcher, John; Burns, Joshua

    2016-01-01

    The total contact cast (TCC) is an effective intervention to reduce plantar pressure in patients with diabetes and a plantar forefoot ulcer. The walls of the TCC have been indirectly shown to bear approximately 30 % of the plantar load. A new direct method to measure inside the TCC walls with capacitance sensors has shown that the anterodistal and posterolateral-distal regions of the lower leg bear the highest load. The objective of this study was to directly measure these two regions in patients with Diabetes and a plantar forefoot ulcer to further understand the mechanism of pressure reduction in the TCC. A TCC was applied to 17 patients with Diabetes and a plantar forefoot ulcer. TCC wall load (contact area, peak pressure and max force) at the anterodistal and posterolateral-distal regions of the lower leg were evaluated with two capacitance sensor strips measuring 90 cm(2) (pliance®, novel GmbH, Germany). Plantar load (contact area, peak pressure and max force) was measured with a capacitance sensor insole (pedar®, novel GmbH, Germany) placed inside the TCC. Both pedar® and pliance® collected data simultaneously at a sampling rate of 50Hz synchronised to heel strike. The magnitude of TCC wall load as a proportion of plantar load was calculated. The TCC walls were then removed to determine the differences in plantar loading between the TCC and the cut down shoe-cast for the whole foot, rearfoot, midfoot and forefoot (region of interest). TCC wall load was substantial. The anterodistal lower leg recorded 48 % and the posterolateral-distal lower leg recorded 34 % of plantar contact area. The anterodistal lower leg recorded 28 % and the posterolateral-distal lower leg recorded 12 % of plantar peak pressure. The anterodistal lower leg recorded 12 % and the posterolateral-distal lower leg recorded 4 % of plantar max force. There were significant differences in plantar load between the TCC and the cut down shoe-cast for the whole foot, rearfoot, midfoot and

  8. The contact area and sliding friction in nanotribological systems

    International Nuclear Information System (INIS)

    Wolloch, M.

    2014-01-01

    Although friction, wear, and lubrication have been investigated for hundreds of years, many important questions in the field, now dubbed tribology, remain open. Two of these are the determination of the real area of contact and the direction dependence of friction forces on the nanoscale, which are investigated in this thesis. The invention of the atomic force microscope (AFM) in 1986 by Binnig , Quate, and Gerber was invaluable for the investigation of frictional forces on the atomic scale, giving a boost to the emerging field of nanotribology. While experimental AFM set-ups where quickly modeled with classical molecular dynamic (MD) simulations, the use of 'ab-initio' methods on tribological problems remained scarce until recently. In this thesis density functional theory (DFT) is used to develop parameter free methods in the field of nanotribology. Since the discovery that the apparent area of contact can be orders of magnitude larger than the true area of contact, the definition and determination of the latter has been an important topic of research. While classical contact mechanics provides satisfactory theories and results for various macroscopic systems, the application of these methods to atomistic systems is dubious, as the contacting bodies are not continuous at this length scale. We developed a parameter free approach to define and calculate the real area of contact between two bodies depending on distance. Strong relaxations at distinct distances, like the j ump to contact , which is often observed in AFM experiments, are used to define the onset of contact and Bader-s Quantum Theory of Atoms in Molecules is used to calculate the real area of contact at a given distance. Bader's method partitions the charge density ρ unambiguously into atoms, which theoretically fill all space and thus give non zero contact areas for all distances. It is therefore necessary to use a density cutoff ρ cut which assigns all regions in space where ρ <

  9. Changes in Contact Area in Meniscus Horizontal Cleavage Tears Subjected to Repair and Resection.

    Science.gov (United States)

    Beamer, Brandon S; Walley, Kempland C; Okajima, Stephen; Manoukian, Ohan S; Perez-Viloria, Miguel; DeAngelis, Joseph P; Ramappa, Arun J; Nazarian, Ara

    2017-03-01

    To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier

  10. Current Enhancement with Contact-Area-Limited Doping for Bottom-Gate, Bottom-Contact Organic Thin-Film Transistors

    Science.gov (United States)

    Noda, Kei; Wakatsuki, Yusuke; Yamagishi, Yuji; Wada, Yasuo; Toyabe, Toru; Matsushige, Kazumi

    2013-02-01

    The current enhancement mechanism in contact-area-limited doping for bottom-gate, bottom-contact (BGBC) p-channel organic thin-film transistors (OTFTs) was investigated both by simulation and experiment. Simulation results suggest that carrier shortage and large potential drop occur in the source-electrode/channel interface region in a conventional BGBC OTFT during operation, which results in a decrease in the effective field-effect mobility. These phenomena are attributed to the low carrier concentration of active semiconductor layers in OTFTs and can be alleviated by contact-area-limited doping, where highly doped layers are prepared over source-drain electrodes. According to two-dimensional current distribution obtained from the device simulation, a current flow from the source electrode to the channel region via highly doped layers is generated in addition to the direct carrier injection from the source electrode to the channel, leading to the enhancement of the drain current and effective field-effect mobility. The expected current enhancement mechanism in contact-area-limited doping was experimentally confirmed in typical α-sexithiophene (α-6T) BGBC thin-film transistors.

  11. Growth of contact area between rough surfaces under normal stress

    Science.gov (United States)

    Stesky, R. M.; Hannan, S. S.

    1987-05-01

    The contact area between deforming rough surfaces in marble, alabaster, and quartz was measured from thin sections of surfaces bonded under load with low viscosity resin epoxy. The marble and alabaster samples had contact areas that increased with stress at an accelerating rate. This result suggests that the strength of the asperity contacts decreased progressively during the deformation, following some form of strain weakening relationship. This conclusion is supported by petrographic observation of the thin sections that indicate that much of the deformation was cataclastic, with minor twinning of calcite and kinking of gypsum. In the case of the quartz, the observed contact area was small and increased approximately linearly with normal stress. Only the irreversible cataclastic deformation was observed; however strain-induced birefringence and cracking of the epoxy, not observed with the other rocks, suggests that significant elastic deformation occurred, but recovered during unloading.

  12. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    Science.gov (United States)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  13. The steady-state tangential contact problem for a falling drop type of contact area on corrugated rail by simplified theory of rolling contact

    Science.gov (United States)

    Piotrowski, Jerzy

    1991-10-01

    Investigation of contact mechanical nonlinearities of a mathematical model of corrugation revealed that the typical shape of contact patch resembles a falling drop of water. A contact patch of that shape was approximated with a figure composed of two parts of ellipses with different eccentricities. The contact pressure distribution was assumed as a smoothing ensemble of two paraboloidal distributions. The description of a general case of double half elliptical contact area was given but a special case of double half elliptical contact is more interesting as it possesses some Hertzian properties. It was shown how three geometrical parameters of double half elliptical contact can be chosen when actual, non-Hertzian contact is known. A linear theory was written which indicates that the lateral vibrations of the rail may be excited only due to shape variation on corrugation even if any other cause for these vibrations does not exist. For nonlinear theory a computer program, based on FASTSIM algorithm by Kalker, was written. The aim is to calculate the creep forces and frictional power density distribution over the contact area. Also, a graphic program visualizing the solution was written. Numerical results are not provided; unattended and unsolved problems relevant for this type of contact are listed.

  14. Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness.

    Science.gov (United States)

    Abduo, Jaafar

    2017-01-01

    This study evaluated and compared the effect of conventional and digital wax-ups on three lateral occlusion variables: contact number, contact area, and steepness. Dental casts of 10 patients with Angle Class I relationship were included in the study. All patients required fixed prosthodontic treatment that would affect lateral occlusion. The casts of all patients received conventional and digital wax-ups. For pretreatment, conventional wax-up, and digital wax-up casts, contact number, contact area, and occlusion steepness were measured at four lateral positions, that is, at excursions of 0.5, 1.0, 2.0, and 3.0 mm from maximal intercuspation. Lateral occlusion scheme variables were affected by use of diagnostic wax-ups. For all types of casts, contact number decreased as excursion increased. The two types of wax-ups had similar contact number patterns, and contact number was significantly greater for these casts than for pretreatment casts in the earlier stages of excursion. Similarly, contact area gradually decreased with increasing excursion in the pretreatment and conventional and digital wax-up casts. There was only a minimal decrease in occlusion steepness as excursion increased. However, lateral occlusion was generally steeper for digital wax-up casts.

  15. Large area optical mapping of surface contact angle.

    Science.gov (United States)

    Dutra, Guilherme; Canning, John; Padden, Whayne; Martelli, Cicero; Dligatch, Svetlana

    2017-09-04

    Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.

  16. Labral reconstruction with iliotibial band autografts and semitendinosus allografts improves hip joint contact area and contact pressure: an in vitro analysis.

    Science.gov (United States)

    Lee, Simon; Wuerz, Thomas H; Shewman, Elizabeth; McCormick, Frank M; Salata, Michael J; Philippon, Marc J; Nho, Shane J

    2015-01-01

    Labral reconstruction using iliotibial band (ITB) autografts and semitendinosus (Semi-T) allografts has recently been described in cases of labral deficiency. To characterize the joint biomechanics with a labrum-intact, labrum-deficient, and labrum-reconstructed acetabulum in a hip cadaveric model. The hypothesis was that labral resection would decrease contact area, increase contact pressure, and increase peak force, while subsequent labral reconstruction with ITB autografts or Semi-T allografts would restore these values toward the native intact labral state. Controlled laboratory study. Ten fresh-frozen human cadaveric hips were analyzed utilizing thin-film piezoresistive load sensors to measure contact area, contact pressure, and peak force (1) with the native intact labrum, (2) after segmental labral resection, and (3) after graft labral reconstruction with either ITB autografts or Semi-T allografts. Each specimen was examined at 20° of extension and 60° of flexion. Statistical analysis was conducted through 1-way analysis of variance with post hoc Games-Howell tests. For the ITB group, labral resection significantly decreased contact area (at 20°: 73.2%±5.38%, P=.0010; at 60°: 78.5%±6.93%, P=.0063) and increased contact pressure (at 20°: 106.7%±4.15%, P=.0387; at 60°: 103.9%±1.15%, P=.0428). In addition, ITB reconstruction improved contact area (at 20°: 87.2%±12.3%, P=.0130; at 60°: 90.5%±8.81%, P=.0079) and contact pressure (at 20°: 98.5%±5.71%, P=.0476; at 60°: 96.6%±1.13%, P=.0056) from the resected state. Contact pressure at 60° of flexion was significantly lower compared with the native labrum (P=.0420). For the Semi-T group, labral resection significantly decreased contact area (at 20°: 68.1%±12.57%, P=.0002; at 60°: 67.5%±6.70%, P=.0002) and increased contact pressure (at 20°: 105.3%±3.73%, P=.0304; at 60°: 106.8%±4.04%, P=.0231). Semi-T reconstruction improved contact area (at 20°: 87.9%±7.95%, P=.0087; at 60°: 92.9%±13

  17. Atomistic simulations of contact area and conductance at nanoscale interfaces.

    Science.gov (United States)

    Hu, Xiaoli; Martini, Ashlie

    2017-11-09

    Atomistic simulations were used to study conductance across the interface between a nanoscale gold probe and a graphite surface with a step edge. Conductance on the graphite terrace was observed to increase with load and be approximately proportional to contact area calculated from the positions of atoms in the interface. The relationship between area and conductance was further explored by varying the position of the contact relative to the location of the graphite step edge. These simulations reproduced a previously-reported current dip at step edges measured experimentally and the trend was explained by changes in both contact area and the distribution of distances between atoms in the interface. The novel approach reported here provides a foundation for future studies of the fundamental relationships between conductance, load and surface topography at the atomic scale.

  18. Self-affine roughness effects on the contact area between elastic bodies

    NARCIS (Netherlands)

    Palasantzas, G; De Hosson, JTM

    2003-01-01

    We have calculated the real contact area between elastic bodies with self-affine rough surfaces, which are described in terms of analytical correlation models in Fourier space. It is found that the roughness has a strong influence on the real contact area A(lambda) at lateral length scales lambda

  19. High inter-specimen variability of baseline data for the tibio-talar contact area.

    Science.gov (United States)

    Matricali, Giovanni A; Bartels, Ward; Labey, Luc; Dereymaeker, Greta Ph E; Luyten, Frank P; Vander Sloten, Jos

    2009-01-01

    The tibio-talar contact area has been widely investigated to monitor biomechanical changes due to articular incongruities or an altered loading. This study aims to investigate for the first time in a systematic way the extent of the inter-specimen variability of the tibio-talar contact area, and its repercussions when analyzing data concerning this parameter. Ten specimens were loaded to record the tibio-talar contact characteristics by use of pressure sensitive film. The size of the talar dome area, the size of the (normalized) tibio-talar contact area, the position of the tibio-talar contact area, and the shape of the latter were determined and analyzed. Inter-specimen variability was expressed as the coefficient of variation and was calculated for the datasets of previous studies as well. The size of the tibio-talar contact area showed a very high inter-specimen variability, as is the case in previous studies. This high variability persisted when a normalized tibio-talar contact area was calculated. The shape of the tibio-talar contact area showed some basic characteristics, but a high variation in details could be observed. Every specimen can be considered to have its own "ankle print". By this variability, articular incongruities are expected to have a different effect on local biomechanical characteristics in every single individual. Therefore, every single case has to be evaluated and reported for significant changes. In case of modeling, this also underscores the need to use subject specific models fed by sets of parameters derived from a series of single specimens.

  20. Contact area calculation between elastic solids bounded by mound rough surfaces

    NARCIS (Netherlands)

    Palasantzas, G

    In this work, we investigate the influence of mound roughness on the contact area between elastic bodies. The mound roughness is described by the r.m.s. roughness amplitude w, the average mound separation Lambda, and the system correlation length xi. In general, the real contact area has a complex

  1. Effect of contact area on electron transport through graphene-metal interface.

    Science.gov (United States)

    Liu, Hongmei; Kondo, Hisashi; Ohno, Takahisa

    2013-08-21

    We perform first-principles investigations of electron transport in armchair graphene nanoribbons adsorbed on Cu(111) and Ni(111) surfaces with various contact areas. We find that the contact area between metals and graphene has different influences on the conductance. The Cu-graphene system shows an increase in differential conductance for more contact area at a low bias voltage, primarily originating from the shift of transmission peaks relative to the Fermi energy. As the bias increases, there is an irregular change of conductance, including a weak negative differential conductance for more contact area. In contrast, the conductance of the Ni-graphene junction is monotonically enhanced with increasing overlap area. The minority spin which shows a broad transmission is responsible for the conductance increase of Ni-graphene. These behaviors can be attributed to different mechanisms of the interfacial electron transport: Charge transfer between graphene and Cu largely dominates the transmission enhancement of Cu-graphene, whereas hybridization between graphene and Ni states plays a more important role in the transmission enhancement of Ni-graphene. The different behaviors of transmission increase correlate with not only the strength of the graphene-metal interaction but also the location of metal d states.

  2. Microscopic contact area and friction between medical textiles and skin.

    Science.gov (United States)

    Derler, S; Rotaru, G-M; Ke, W; El Issawi-Frischknecht, L; Kellenberger, P; Scheel-Sailer, A; Rossi, R M

    2014-10-01

    The mechanical contact between medical textiles and skin is relevant in the health care for patients with vulnerable skin or chronic wounds. In order to gain new insights into the skin-textile contact on the microscopic level, the 3D surface topography of a normal and a new hospital bed sheet with a regular surface structure was measured using a digital microscope. The topographic data was analysed concerning material distribution and real contact area against smooth surfaces as a function of surface deformations. For contact conditions that are relevant for the skin of patients lying in a hospital bed it was found that the order of magnitude of the ratio of real and apparent contact area between textiles and skin or a mechanical skin model lies between 0.02 and 0.1 and that surface deformations, i.e. penetration of the textile surface asperities into skin or a mechanical skin model, range from 10 to 50µm. The performed analyses of textile 3D surface topographies and comparisons with previous friction measurement results provided information on the relationship between microscopic surface properties and macroscopic friction behaviour of medical textiles. In particular, the new bed sheet was found to be characterised by a trend towards a smaller microscopic contact area (up to a factor of two) and by a larger free interfacial volume (more than a factor of two) in addition to a 1.5 times lower shear strength when in contact with counter-surfaces. The applied methods can be useful to develop improved and skin-adapted materials and surfaces for medical applications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. A Novel Algorithm for Determining Contact Area Between a Respirator and a Headform

    OpenAIRE

    Lei, Zhipeng; Yang, James; Zhuang, Ziqing

    2014-01-01

    The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 ...

  4. Prediction of contact mechanics in metal-on-metal Total Hip Replacement for parametrically comprehensive designs and loads.

    Science.gov (United States)

    Donaldson, Finn E; Nyman, Edward; Coburn, James C

    2015-07-16

    Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation. Published by Elsevier Ltd.

  5. Cell-Cell Contact Area Affects Notch Signaling and Notch-Dependent Patterning.

    Science.gov (United States)

    Shaya, Oren; Binshtok, Udi; Hersch, Micha; Rivkin, Dmitri; Weinreb, Sheila; Amir-Zilberstein, Liat; Khamaisi, Bassma; Oppenheim, Olya; Desai, Ravi A; Goodyear, Richard J; Richardson, Guy P; Chen, Christopher S; Sprinzak, David

    2017-03-13

    During development, cells undergo dramatic changes in their morphology. By affecting contact geometry, these morphological changes could influence cellular communication. However, it has remained unclear whether and how signaling depends on contact geometry. This question is particularly relevant for Notch signaling, which coordinates neighboring cell fates through direct cell-cell signaling. Using micropatterning with a receptor trans-endocytosis assay, we show that signaling between pairs of cells correlates with their contact area. This relationship extends across contact diameters ranging from micrometers to tens of micrometers. Mathematical modeling predicts that dependence of signaling on contact area can bias cellular differentiation in Notch-mediated lateral inhibition processes, such that smaller cells are more likely to differentiate into signal-producing cells. Consistent with this prediction, analysis of developing chick inner ear revealed that ligand-producing hair cell precursors have smaller apical footprints than non-hair cells. Together, these results highlight the influence of cell morphology on fate determination processes. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. The Change in Fingertip Contact Area as a Novel Proprioceptive Cue.

    Science.gov (United States)

    Moscatelli, Alessandro; Bianchi, Matteo; Serio, Alessandro; Terekhov, Alexander; Hayward, Vincent; Ernst, Marc O; Bicchi, Antonio

    2016-05-09

    Humans, many animals, and certain robotic hands have deformable fingertip pads [1, 2]. Deformable pads have the advantage of conforming to the objects that are being touched, ensuring a stable grasp for a large range of forces and shapes. Pad deformations change with finger displacements during touch. Pushing a finger against an external surface typically provokes an increase of the gross contact area [3], potentially providing a relative motion cue, a situation comparable to looming in vision [4]. The rate of increase of the area of contact also depends on the compliance of the object [5]. Because objects normally do not suddenly change compliance, participants may interpret an artificially induced variation in compliance, which coincides with a change in the gross contact area, as a change in finger displacement, and consequently they may misestimate their finger's position relative to the touched object. To test this, we asked participants to compare the perceived displacements of their finger while contacting an object varying pseudo-randomly in compliance from trial to trial. Results indicate a bias in the perception of finger displacement induced by the change in compliance, hence in contact area, indicating that participants interpreted the altered cutaneous input as a cue to proprioception. This situation highlights the capacity of the brain to take advantage of knowledge of the mechanical properties of the body and of the external environment. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Post-Cam Design and Contact Stress on Tibial Posts in Posterior-Stabilized Total Knee Prostheses: Comparison Between a Rounded and a Squared Design.

    Science.gov (United States)

    Watanabe, Toshifumi; Koga, Hideyuki; Horie, Masafumi; Katagiri, Hiroki; Sekiya, Ichiro; Muneta, Takeshi

    2017-12-01

    The post-cam mechanism in posterior stabilized (PS) prostheses plays an important role in total knee arthroplasty (TKA). The purpose of this study is to clarify the difference of the contact stress on the tibial post between a rounded post-cam design and a squared design during deep knee flexion and at hyperextension using the three-dimensional (3D) finite element models. We created 2 types of 3D, finite element models of PS prostheses (types A and B), whose surfaces were identical except for the post-cam geometries: type A has a rounded post-cam design, while type B has a squared design. Both types have a similar curved-shape intercondylar notch of the femoral component. Stress distributions, peak contact stresses, and contact areas on the tibial posts at 90°, 120°, and 150° flexion with/without 10° tibial internal rotation and at 10° hyperextension were compared between the 2 models. Type B demonstrated more concentrated stress distribution compared to type A. The peak contact stresses were similar in both groups during neutral flexion; however, the stresses were much higher in type B during flexion with 10° rotation and at hyperextension. The higher peak contact stresses corresponded to the smaller contact areas in the tibial post. A rounded post-cam design demonstrated less stress concentration during flexion with rotation and at hyperextension compared with a squared design. The results would be useful for development of implant designs and prediction of the contact stress on the tibial post in PS total knee arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Non-contact ulcer area calculation system for neuropathic foot ulcer.

    Science.gov (United States)

    Shah, Parth; Mahajan, Siddaram; Nageswaran, Sharmila; Paul, Sathish Kumar; Ebenzer, Mannam

    2017-08-11

    Around 125,785 new cases in year 2013-14 of leprosy were detected in India as per WHO report on leprosy in September 2015 which accounts to approximately 62% of the total new cases. Anaesthetic foot caused by leprosy leads to uneven loading of foot leading to ulcer in approximately 20% of the cases. Much efforts have gone in identifying newer techniques to efficiently monitor the progress of ulcer healing. Current techniques followed in measuring the size of ulcers, have not been found to be so accurate but are still is followed by clinicians across the globe. Quantification of prognosis of the condition would be required to understand the efficacy of current treatment methods and plan for further treatment. This study aims at developing a non contact technique to precisely measure the size of ulcer in patients affected by leprosy. Using MATLAB software, GUI was designed to process the acquired ulcer image by segmenting and calculating the pixel area of the image. The image was further converted to a standard measurement using a reference object. The developed technique was tested on 16 ulcer images acquired from 10 leprosy patients with plantar ulcers. Statistical analysis was done using MedCalc analysis software to find the reliability of the system. The analysis showed a very high correlation coefficient (r=0.9882) between the ulcer area measurements done using traditional technique and the newly developed technique, The reliability of the newly developed technique was significant with a significance level of 99.9%. The designed non-contact ulcer area calculating system using MATLAB is found to be a reliable system in calculating the size of ulcers. The technique would help clinicians have a reliable tool to monitor the progress of ulcer healing and help modify the treatment protocol if needed. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  9. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein-Protein Interactions.

    Science.gov (United States)

    Kang, Beom Sik; Pugalendhi, GaneshKumar; Kim, Ku-Jin

    2017-10-13

    Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  10. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein–Protein Interactions

    Directory of Open Access Journals (Sweden)

    Beom Sik Kang

    2017-10-01

    Full Text Available Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  11. Analysis of main parameters affecting substrate/mortar contact area through tridimensional laser scanner.

    Science.gov (United States)

    Stolz, Carina M; Masuero, Angela B

    2015-10-01

    This study assesses the influence of the granulometric composition of sand, application energy and the superficial tension of substrates on the contact area of rendering mortars. Three substrates with distinct wetting behaviors were selected and mortars were prepared with different sand compositions. Characterization tests were performed on fresh and hardened mortars, as well as the rheological characterization. Mortars were applied to substrates with two different energies. The interfacial area was then digitized with 3D scanner. Results show that variables are all of influence on the interfacial contact in the development area. Furthermore, 3D laser scanning proved to be a good method to contact area measurement. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Evaluation of recovery in lip closing pressure and occlusal force and contact area after orthognathic surgery.

    Science.gov (United States)

    Ueki, Koichiro; Moroi, Akinori; Sotobori, Megumi; Ishihara, Yuri; Marukawa, Kohei; Iguchi, Ran; Kosaka, Akihiko; Ikawa, Hiroumi; Nakazawa, Ryuichi; Higuchi, Masatoshi

    2014-10-01

    The purpose of this study was to evaluate the relationship between lip closing force, occlusal contact area and occlusal force after orthognathic surgery in skeletal Class III patients. The subjects consisted of 54 patients (28 female and 26 male) diagnosed with mandibular prognathism who underwent sagittal split ramus osteotomy with and without Le Fort I osteotomy. Maximum and minimum lip closing forces, occlusal contact area and occlusal force were measured pre-operatively, 6 months and 1 year post-operative. Maximum and minimum lip closing forces, occlusal contact area and occlusal force increased with time after surgery, however a significant increase was not found in the occlusal contact area in women. In increased ratio (6 months/pre-operative and 1 year/pre-operative), the maximum lip closing force was significantly correlated with the occlusal contact area (P contact area and lip closing force, and an increase ratio in maximum lip closing force was associated with an increased ratio in occlusal contact area. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Opening wedge trapezial osteotomy as possible treatment for early trapeziometacarpal osteoarthritis: a biomechanical investigation of radial subluxation, contact area, and contact pressure.

    Science.gov (United States)

    Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana

    2012-04-01

    Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first

  14. Pattern of maxillary and mandibular proximal enamel thickness at the contact area of the permanent dentition from first molar to first molar.

    Science.gov (United States)

    Sarig, Rachel; Vardimon, Alexander D; Sussan, Celine; Benny, Lea; Sarne, Ofer; Hershkovitz, Israel; Shpack, Nir

    2015-04-01

    Proximal enamel thickness (PET) at the mesial and distal contact areas of the complete permanent dentition has not been previously reported. Anatomic investigation of PET is essential for interproximal reduction treatment. Our objectives were to measure the PETs of the complete maxillary and mandibular dentitions at the contact areas, to compare the PETs of adjacent teeth, and to evaluate the vertical position of each contact area. We evaluated 720 extracted teeth; of these, 109 intact teeth were selected. The mesial and distal contact areas were demarcated, and each tooth was embedded in transparent epoxy resin. Blocks were prepared so that the 2 demarcated contact areas were exposed, and 6 measurements were taken and statistically analyzed. Both jaws showed the same PET pattern characterized by 5 features: PET increased progressively from incisor (0.63 mm) to first molar (1.48 mm). Per tooth, mesial and distal PET did not differ. Total maxillary (26.86 mm) and mandibular (24.52 mm) PETs were similar. Paired PETs at the interproximal interface were similar, with the exception of the lateral incisor-canine interfaces. From incisor to first molar, the contact area becomes located farther gingivally. The existing guideline of maximal 0.5-mm interproximal reduction per 2 adjacent teeth should be kept in the anterior region and could be increased to 1 mm in the posterior region, when an equal amount is removed. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  15. Evolution of real contact area under shear and the value of static friction of soft materials.

    Science.gov (United States)

    Sahli, R; Pallares, G; Ducottet, C; Ben Ali, I E; Al Akhrass, S; Guibert, M; Scheibert, J

    2018-01-16

    The frictional properties of a rough contact interface are controlled by its area of real contact, the dynamical variations of which underlie our modern understanding of the ubiquitous rate-and-state friction law. In particular, the real contact area is proportional to the normal load, slowly increases at rest through aging, and drops at slip inception. Here, through direct measurements on various contacts involving elastomers or human fingertips, we show that the real contact area also decreases under shear, with reductions as large as 30[Formula: see text], starting well before macroscopic sliding. All data are captured by a single reduction law enabling excellent predictions of the static friction force. In elastomers, the area-reduction rate of individual contacts obeys a scaling law valid from micrometer-sized junctions in rough contacts to millimeter-sized smooth sphere/plane contacts. For the class of soft materials used here, our results should motivate first-order improvements of current contact mechanics models and prompt reinterpretation of the rate-and-state parameters.

  16. Effect of radial head implant shape on joint contact area and location during static loading.

    Science.gov (United States)

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Contact area of rough spheres: Large scale simulations and simple scaling laws

    Energy Technology Data Exchange (ETDEWEB)

    Pastewka, Lars, E-mail: lars.pastewka@kit.edu [Institute for Applied Materials & MicroTribology Center muTC, Karlsruhe Institute of Technology, Engelbert-Arnold-Straße 4, 76131 Karlsruhe (Germany); Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218 (United States); Robbins, Mark O., E-mail: mr@pha.jhu.edu [Department of Physics and Astronomy, Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218 (United States)

    2016-05-30

    We use molecular simulations to study the nonadhesive and adhesive atomic-scale contact of rough spheres with radii ranging from nanometers to micrometers over more than ten orders of magnitude in applied normal load. At the lowest loads, the interfacial mechanics is governed by the contact mechanics of the first asperity that touches. The dependence of contact area on normal force becomes linear at intermediate loads and crosses over to Hertzian at the largest loads. By combining theories for the limiting cases of nominally flat rough surfaces and smooth spheres, we provide parameter-free analytical expressions for contact area over the whole range of loads. Our results establish a range of validity for common approximations that neglect curvature or roughness in modeling objects on scales from atomic force microscope tips to ball bearings.

  18. Contact area of rough spheres: Large scale simulations and simple scaling laws

    Science.gov (United States)

    Pastewka, Lars; Robbins, Mark O.

    2016-05-01

    We use molecular simulations to study the nonadhesive and adhesive atomic-scale contact of rough spheres with radii ranging from nanometers to micrometers over more than ten orders of magnitude in applied normal load. At the lowest loads, the interfacial mechanics is governed by the contact mechanics of the first asperity that touches. The dependence of contact area on normal force becomes linear at intermediate loads and crosses over to Hertzian at the largest loads. By combining theories for the limiting cases of nominally flat rough surfaces and smooth spheres, we provide parameter-free analytical expressions for contact area over the whole range of loads. Our results establish a range of validity for common approximations that neglect curvature or roughness in modeling objects on scales from atomic force microscope tips to ball bearings.

  19. Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.

    Science.gov (United States)

    Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K

    2013-11-01

    To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (pcontact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (Pcontact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.

  20. Evolution of the Contact Area with Normal Load for Rough Surfaces: from Atomic to Macroscopic Scales.

    Science.gov (United States)

    Huang, Shiping

    2017-11-13

    The evolution of the contact area with normal load for rough surfaces has great fundamental and practical importance, ranging from earthquake dynamics to machine wear. This work bridges the gap between the atomic scale and the macroscopic scale for normal contact behavior. The real contact area, which is formed by a large ensemble of discrete contacts (clusters), is proven to be much smaller than the apparent surface area. The distribution of the discrete contact clusters and the interaction between them are key to revealing the mechanism of the contacting solids. To this end, Green's function molecular dynamics (GFMD) is used to study both how the contact cluster evolves from the atomic scale to the macroscopic scale and the interaction between clusters. It is found that the interaction between clusters has a strong effect on their formation. The formation and distribution of the contact clusters is far more complicated than that predicted by the asperity model. Ignorance of the interaction between them leads to overestimating the contacting force. In real contact, contacting clusters are smaller and more discrete due to the interaction between the asperities. Understanding the exact nature of the contact area with the normal load is essential to the following research on friction.

  1. Tibiofemoral joint contact area and pressure after single- and double-bundle anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Morimoto, Yusuke; Ferretti, Mario; Ekdahl, Max; Smolinski, Patrick; Fu, Freddie H

    2009-01-01

    The purpose of this study was to compare the tibiofemoral contact area and pressure after single-bundle (SB) and double-bundle (DB) anterior cruciate ligament (ACL) reconstruction by use of 2 femoral and 2 tibial tunnels in intact cadaveric knees. Tibiofemoral contact area and mean and maximum pressures were measured by pressure-sensitive film (Fujifilm, Valhalla, NY) inserted between the tibia and femur. The knee was subjected to a 1,000-N axial load by use of a uniaxial testing machine at 0 degrees , 15 degrees , 30 degrees , and 45 degrees of flexion. Three conditions were evaluated: (1) intact ACL, (2) SB ACL reconstruction (n = 10 knees), and (3) DB ACL reconstruction (n = 9 knees). When compared with the intact knee, DB ACL reconstruction showed no significant difference in tibiofemoral contact area and mean and maximum pressures. SB ACL reconstruction had a significantly smaller contact area on the lateral and medial tibiofemoral joints at 30 degrees and 15 degrees of flexion. SB ACL reconstruction also had significantly higher mean pressures at 15 degrees of flexion on the medial tibiofemoral joint and at 0 degrees and 15 degrees of flexion on the lateral tibiofemoral joint, as well as significantly higher maximum pressures at 15 degrees of flexion on the lateral tibiofemoral joint. SB ACL reconstruction resulted in a significantly smaller tibiofemoral contact area and higher pressures. DB ACL more closely restores the normal contact area and pressure mainly at low flexion angles. Our findings suggest that the changes in the contact area and pressures after SB ACL reconstruction may be one of the causes of osteoarthritis on long-term follow-up. DB ACL reconstruction may reduce the incidence of osteoarthritis by closely restoring contact area and pressure.

  2. In vivo tibiofemoral cartilage-to-cartilage contact area of females with medial osteoarthritis under acute loading using MRI.

    Science.gov (United States)

    Shin, Choongsoo S; Souza, Richard B; Kumar, Deepak; Link, Thomas M; Wyman, Bradley T; Majumdar, Sharmila

    2011-12-01

    To investigate the effect of acute loading on in vivo tibiofemoral contact area changes in both compartments, and to determine whether in vivo tibiofemoral contact area differs between subjects with medial knee osteoarthritis (OA) and healthy controls. Ten subjects with medial knee OA (KL3) and 11 control subjects (KL0) were tested. Coronal three-dimensional spoiled gradient-recalled (3D-SPGR) and T(2) -weighted fast spin-echo FSE magnetic resonance imaging (MRI) of the knee were acquired under both unloaded and loaded conditions. Tibiofemoral cartilage contact areas were measured using image-based 3D models. Tibiofemoral contact areas in both compartments significantly increased under loading (P contact area in the medial compartment was significantly larger than in the lateral compartment (P contact area was significantly larger in KL3 subjects than KL0 subjects, both at unloaded and loaded conditions (P Contact areas measured from 3D-SPGR and T(2) -weighted FSE images were strongly correlated (r = 0.904). Females with medial OA increased tibiofemoral contact area in the medial compartment compared to healthy subjects under both unloaded and loaded conditions. The contact area data presented in this study may provide a quantitative reference for further cartilage contact biomechanics such as contact stress analysis and cartilage biomechanical function difference between osteoarthritic and healthy knees. Copyright © 2011 Wiley Periodicals, Inc.

  3. Comparison Between Bandage Contact Lenses and Pressure Patching on the Erosion Area and Pain Scale in Patients With Corneal Erosion.

    Science.gov (United States)

    Triharpini, Ni Nyoman; Gede Jayanegara, I Wayan; Handayani, Ariesanti Tri; Widiana, I Gde Raka

    2015-01-01

    Corneal erosion is common in eye emergency cases. Extensive corneal erosions result in severe pain and prolonged healing time. This study aimed to compare bandage contact lenses with pressure patching in terms of reducing the size of the erosion area, pain scale in patients with corneal erosion and its complications. A randomized open-label clinical trial was conducted. Subjects with mechanical corneal erosion were selected to use either bandage contact lenses or pressure patching. All subjects received antibiotic eye drops and 0.5% tropicamide eye drops. Evaluations were done 24 and 72 hours after treatment. The size of the corneal erosion area, pain scale, and complications were assessed. A total of 32 eyes (16 eyes in each group) were studied. The change in the size of the corneal erosion area was greater in the bandage contact lens group than in the pressure patching group, although there was no significant difference. In the bandage contact lens group, 56.25% of the eyes were healed at 24 hours and 43.75% were healed at 72 hours. In the pressure patching group, 62.50% were healed at 24 hours and 12.50% were healed at 72 hours. The change in pain scale was significantly greater in the bandage contact lens group than in the pressure patching group. No complications were found in both groups. Bandage contact lenses are an effective alternative to treating mechanical corneal erosion because of their effect in reducing pain without causing any complications.

  4. Determination of the total attenuation coefficient for six contact lens materials using the Beer-Lambert law.

    Science.gov (United States)

    Hull, C C; Crofts, N C

    1996-03-01

    The Beer-Lambert law has been used to determine the total attenuation coefficient, mu t, of three hard and three soft contact lens materials. The three hard contact lens materials were PMMA, Polycon II and Boston IV whereas the 3 soft materials were chosen with differing water contents of 38, 55 and 70%, respectively. The total attenuation coefficients of all six materials were obtained from measurements of the axial transmission at 632.8 nm of a series of plano powered lenses varying in axial thickness from 0.5 to 3.5 mm. The value of the total attenuation coefficient depends on both scattering and absorption and hence PMMA and Boston IV, which both incorporated a handling tint, showed significantly higher values (P 0.5) was found between any of the hydrated soft contact lens materials tested.

  5. Time Dependent Frictional Changes in Ice due to Contact Area Changes

    Science.gov (United States)

    Sevostianov, V.; Lipovsky, B. P.; Rubinstein, S.; Dillavou, S.

    2017-12-01

    Sliding processes along the ice-bed interface of Earth's great ice sheets are the largest contributor to our uncertainty in future sea level rise. Laboratory experiments that have probed sliding processes have ubiquitously shown that ice-rock interfaces strengthen while in stationary contact (Schulson and Fortt, 2013; Zoet et al., 2013; McCarthy et al., 2017). This so-called frictional ageing effect may have profound consequences for ice sheet dynamics because it introduces the possibility of basal strength hysteresis. Furthermore this effect is quite strong in ice-rock interfaces (more than an order of magnitude more pronounced than in rock-rock sliding) and can double in frictional strength in a matter of minutes, much faster than most frictional aging (Dieterich, 1972; Baumberger and Caroli, 2006). Despite this importance, the underling physics of frictional ageing of ice remain poorly understood. Here we conduct laboratory experiments to image the microscopic points of contact along an ice-glass interface. We optically measure changes in the real area of contact over time using measurements of this reflected optical light intensity. We show that contact area increases with time of stationary contact. This result suggests that thermally enhanced creep of microscopic icy contacts is responsible for the much larger frictional ageing observed in ice-rock versus rock-rock interfaces. Furthermore, this supports a more physically detailed description of the thermal dependence of basal sliding than that used in the current generation of large scale ice sheet models.

  6. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    Science.gov (United States)

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  7. Comparison of MRI-based estimates of articular cartilage contact area in the tibiofemoral joint.

    Science.gov (United States)

    Henderson, Christopher E; Higginson, Jill S; Barrance, Peter J

    2011-01-01

    Knee osteoarthritis (OA) detrimentally impacts the lives of millions of older Americans through pain and decreased functional ability. Unfortunately, the pathomechanics and associated deviations from joint homeostasis that OA patients experience are not well understood. Alterations in mechanical stress in the knee joint may play an essential role in OA; however, existing literature in this area is limited. The purpose of this study was to evaluate the ability of an existing magnetic resonance imaging (MRI)-based modeling method to estimate articular cartilage contact area in vivo. Imaging data of both knees were collected on a single subject with no history of knee pathology at three knee flexion angles. Intra-observer reliability and sensitivity studies were also performed to determine the role of operator-influenced elements of the data processing on the results. The method's articular cartilage contact area estimates were compared with existing contact area estimates in the literature. The method demonstrated an intra-observer reliability of 0.95 when assessed using Pearson's correlation coefficient and was found to be most sensitive to changes in the cartilage tracings on the peripheries of the compartment. The articular cartilage contact area estimates at full extension were similar to those reported in the literature. The relationships between tibiofemoral articular cartilage contact area and knee flexion were also qualitatively and quantitatively similar to those previously reported. The MRI-based knee modeling method was found to have high intra-observer reliability, sensitivity to peripheral articular cartilage tracings, and agreeability with previous investigations when using data from a single healthy adult. Future studies will implement this modeling method to investigate the role that mechanical stress may play in progression of knee OA through estimation of articular cartilage contact area.

  8. Fibreglass Total Contact Casting, Removable Cast Walkers, and Irremovable Cast Walkers to Treat Diabetic Neuropathic Foot Ulcers: A Health Technology Assessment

    Science.gov (United States)

    Costa, Vania; Tu, Hong Anh; Wells, David; Weir, Mark; Holubowich, Corinne; Walter, Melissa

    2017-01-01

    Background Diabetic neuropathic foot ulcers are a risk factor for lower leg amputation. Many experts recommend offloading with fibreglass total contact casting, removable cast walkers, and irremovable cast walkers as a way to treat these ulcers. Methods We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences for offloading devices. We performed a systematic literature search on August 17, 2016, to identify randomized controlled trials that compared fibreglass total contact casting, removable cast walkers, and irremovable cast walkers with other treatments (offloading or non-offloading) in patients with diabetic neuropathic foot ulcers. We developed a decision-analytic model to assess the cost-effectiveness of fibreglass total contact casting, removable cast walkers, and irremovable cast walkers, and we conducted a 5-year budget impact analysis. Finally, we interviewed people with diabetes who had lived experience with foot ulcers, asking them about the different offloading devices and the factors that influenced their treatment choices. Results We identified 13 randomized controlled trials. The evidence suggests that total contact casting, removable cast walkers, and irremovable cast walkers are beneficial in the treatment of neuropathic, noninfected foot ulcers in patients with diabetes but without severe peripheral arterial disease. Compared to removable cast walkers, ulcer healing was improved with total contact casting (moderate quality evidence; risk difference 0.17 [95% confidence interval 0.00–0.33]) and irremovable cast walkers (low quality evidence; risk difference 0.21 [95% confidence interval 0.01–0.40]). We found no difference in ulcer healing between total contact casting and irremovable cast walkers (low quality evidence; risk difference 0.02 [95% confidence interval −0.11–0.14]). The economic analysis showed that total contact casting and irremovable

  9. Relationship Between the Electroglottographic Signal and Vocal Fold Contact Area.

    Science.gov (United States)

    Hampala, Vít; Garcia, Maxime; Švec, Jan G; Scherer, Ronald C; Herbst, Christian T

    2016-03-01

    Electroglottography (EGG) is a widely used noninvasive method that purports to measure changes in relative vocal fold contact area (VFCA) during phonation. Despite its broad application, the putative direct relation between the EGG waveform and VFCA has to date only been formally tested in a single study, suggesting an approximately linear relationship. However, in that study, flow-induced vocal fold (VF) vibration was not investigated. A rigorous empirical evaluation of EGG as a measure of VFCA under proper physiological conditions is therefore still needed. Three red deer larynges were phonated in an excised hemilarynx preparation using a conducting glass plate. The time-varying contact between the VF and the glass plate was assessed by high-speed video recordings at 6000 fps, synchronized to the EGG signal. The average differences between the normalized [0, 1] VFCA and EGG waveforms for the three larynges were 0.180 (±0.156), 0.075 (±0.115), and 0.168 (±0.184) in the contacting phase and 0.159 (±0.112), -0.003 (±0.029), and 0.004 (±0.032) in the decontacting phase. Overall, there was a better agreement between VFCA and the EGG waveform in the decontacting phase than in the contacting phase. Disagreements may be caused by nonuniform tissue conductance properties, electrode placement, and electroglottograph hardware circuitry. Pending further research, the EGG waveform may be a reasonable first approximation to change in medial contact area between the VFs during phonation. However, any quantitative and statistical data derived from EGG should be interpreted cautiously, allowing for potential deviations from true VFCA. Copyright © 2016 The Auhors. Published by Elsevier Inc. All rights reserved.

  10. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Takaharu E-mail: yamazaki@image.med.osaka-u.ac.jp; Watanabe, Tetsu; Nakajima, Yoshikazu; Sugamoto, Kazuomi; Tomita, Tetsuya; Maeda, Daisuke; Sahara, Wataru; Yoshikawa, Hideki; Tamura, Shinichi

    2005-01-01

    The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

  11. Technique eliminates high voltage arcing at electrode-insulator contact area

    Science.gov (United States)

    Mealy, G.

    1967-01-01

    Coating the electrode-insulator contact area with silver epoxy conductive paint and forcing the electrode and insulator tightly together into a permanent connection, eliminates electrical arcing in high-voltage electrodes supplying electrical power to vacuum facilities.

  12. Effects of mid-foot contact area ratio on lower body kinetics/kinematics in sagittal plane during stair descent in women.

    Science.gov (United States)

    Lee, Jinkyu; Hong, Yoon No Gregory; Shin, Choongsoo S

    2016-07-01

    The mid-foot contact area relative to the total foot contact area can facilitate foot arch structure evaluation. A stair descent motion consistently provides initial fore-foot contact and utilizes the foot arch more actively for energy absorption. The purpose of this study was to compare ankle and knee joint angle, moment, and work in sagittal plane during stair descending between low and high Mid-Foot-Contact-Area (MFCA) ratio group. The twenty-two female subjects were tested and classified into two groups (high MFCA and low MFCA) using their static MFCA ratios. The ground reaction force (GRF) and kinematics of ankle and knee joints were measured while stair descending. During the period between initial contact and the first peak in vertical GRF (early absorption phase), ankle negative work for the low MFCA ratio group was 33% higher than that for the high MFCA ratio group (pcontact and peak dorsiflexion angle (early absorption phase+late absorption phase). The peak ankle dorsiflexion angle was smaller in the low MFCA ratio group (p<0.05). Our results suggest that strategy of energy absorption at the ankle and foot differs depending upon foot arch types classified by MFCA. The low MFCA ratio group seemed to absorb more impact energy using strain in the planar fascia during early absorption phase, whereas the high MFCA ratio group absorbed more impact energy using increased dorsiflexion during late absorption phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter.

    Science.gov (United States)

    Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A

    2016-04-01

    Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc

  14. A Feasibility Study on the Worn Area Estimation by Measuring a Contact Resistance (I)

    International Nuclear Information System (INIS)

    Lee, Young-Ho; Kim, Hyung-Kyu

    2007-01-01

    In order to improve the fretting wear resistance of the nuclear fuel rod with considering the effect of the contacting spring shape, it is necessary to examine the formation procedure of the worn area during the fretting wear experiments with including its shape, size and the debris removal path. This is because the wear volume and the maximum wear depth are dominantly affected by the worn area and the wear resistance of the nuclear fuel rod was dominantly affected by the spring shape rather than the test environment and the contact mode (i.e. impact, sliding, rubbing, etc.). Unfortunately, it is almost impossible to archive the size and shape of the worn area on real-time basis because the contact surfaces are always hidden. If we could measure the worn area properties during fretting wear tests, it enables us to promptly estimate the wear resistance or behavior with various contacting spring shapes. Generally, fretting wear degradation is generated by the localized plastic deformation, fracture and finally detachment of wear debris. Generally, wear debris easily oxidized by frictional heat, test environment, etc. From the previous studies, most of the wear debris was detached from the worn surface in the distilled water condition while the wear debris in the dry condition remained on or adhered to the worn surface. At this time, it is reasonable that the accumulated wear debris on the worn surface is existed in the form of oxide. If small amount of electric current was applied between the contacting surfaces, wear debris could be an obstacle to flow the electric current. This means that the variation of the contact resistance under constant electric current during the fretting wear tests has much information on the formation of the worn area even though the applying current could accelerate the oxidation of the generated wear debris. So, in this study, fretting wear tests have been performed with applying an electric current in room temperature air in order to

  15. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    Science.gov (United States)

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  16. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    Science.gov (United States)

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  17. Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

    Science.gov (United States)

    Witt, Florian; Gührs, Julian; Morlock, Michael M; Bishop, Nicholas E

    2015-01-01

    Corrosion of modular taper junctions of hip implants may be associated with clinical failure. Taper design parameters, as well as the intraoperatively applied assembly forces, have been proposed to affect corrosion. Fretting corrosion is related to relative interface shear motion and fluid ingress, which may vary with contact force and area. It was hypothesised in this study that assembly forces modify the extent and distribution of the surface contact area at the taper interface between a cobalt chrome head and titanium stem taper with a standard threaded surface profile. Local abrasion of a thin gold coating applied to the stem taper prior to assembly was used to determine the contact area after disassembly. Profilometry was then used to assess permanent deformation of the stem taper surface profile. With increasing assembly force (500 N, 2000 N, 4000 N and 8000 N) the number of stem taper surface profile ridges in contact with the head taper was found to increase (9.2±9.3%, 65.4±10.8%, 92.8±6.0% and 100%) and the overall taper area in contact was also found to increase (0.6±0.7%, 5.5±1.0%, 9.9±1.1% and 16.1±0.9%). Contact was inconsistently distributed over the length of the taper. An increase in plastic radial deformation of the surface ridges (-0.05±0.14 μm, 0.1±0.14 μm, 0.21±0.22 μm and 0.96±0.25 μm) was also observed with increasing assembly force. The limited contact of the taper surface ridges at lower assembly forces may influence corrosion rates, suggesting that the magnitude of the assembly force may affect clinical outcome. The method presented provides a simple and practical assessment of the contact area at the taper interface.

  18. CONTACT RESISTANCE MODELING

    Directory of Open Access Journals (Sweden)

    S. V. LOSKUTOV

    2018-05-01

    Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.

  19. Longitudinal analysis of tibiofemoral cartilage contact area and position in ACL reconstructed patients.

    Science.gov (United States)

    Chen, Ellison; Amano, Keiko; Pedoia, Valentina; Souza, Richard B; Ma, C Benjamin; Li, Xiaojuan

    2018-04-18

    Patients who have suffered ACL injury are more likely to develop early onset post-traumatic osteoarthritis despite reconstruction. The purpose of our study was to evaluate the longitudinal changes in the tibiofemoral cartilage contact area size and location after ACL injury and reconstruction. Thirty-one patients with isolated unilateral ACL injury were followed with T 2 weighted Fast Spin Echo, T 1ρ and T 2 MRI at baseline prior to reconstruction, and 6 months, 1 year, and 2 years after surgery. Areas were delineated in FSE images with an in-house Matlab program using a spline-based semi-automated segmentation algorithm. Tibiofemoral contact area and centroid position along the anterior-posterior axis were calculated along with T 1ρ and T 2 relaxation times on both the injured and non-injured knees. At baseline, the injured knees had significantly smaller and more posteriorly positioned contact areas on the medial tibial surface compared to corresponding healthy knees. These differences persisted 6 months after reconstruction. Moreover, subjects with more anterior medial centroid positions at 6 months had elevated T 1ρ and T 2 measures in the posterior medial tibial plateau at 1 year. Changes in contact area and centroid position after ACL injury and reconstruction may characterize some of the mechanical factors contributing to post-traumatic osteoarthritis. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. A Mathematical Method to Calculate Tumor Contact Surface Area: An Effective Parameter to Predict Renal Function after Partial Nephrectomy.

    Science.gov (United States)

    Hsieh, Po-Fan; Wang, Yu-De; Huang, Chi-Ping; Wu, Hsi-Chin; Yang, Che-Rei; Chen, Guang-Heng; Chang, Chao-Hsiang

    2016-07-01

    We proposed a mathematical formula to calculate contact surface area between a tumor and renal parenchyma. We examined the applicability of using contact surface area to predict renal function after partial nephrectomy. We performed this retrospective study in patients who underwent partial nephrectomy between January 2012 and December 2014. Based on abdominopelvic computerized tomography or magnetic resonance imaging, we calculated the contact surface area using the formula (2*π*radius*depth) developed by integral calculus. We then evaluated the correlation between contact surface area and perioperative parameters, and compared contact surface area and R.E.N.A.L. (Radius/Exophytic/endophytic/Nearness to collecting system/Anterior/Location) score in predicting a reduction in renal function. Overall 35, 26 and 45 patients underwent partial nephrectomy with open, laparoscopic and robotic approaches, respectively. Mean ± SD contact surface area was 30.7±26.1 cm(2) and median (IQR) R.E.N.A.L. score was 7 (2.25). Spearman correlation analysis showed that contact surface area was significantly associated with estimated blood loss (p=0.04), operative time (p=0.04) and percent change in estimated glomerular filtration rate (p contact surface area and R.E.N.A.L. score independently affected percent change in estimated glomerular filtration rate (p contact surface area was a better independent predictor of a greater than 10% change in estimated glomerular filtration rate compared to R.E.N.A.L. score (AUC 0.86 vs 0.69). Using this simple mathematical method, contact surface area was associated with surgical outcomes. Compared to R.E.N.A.L. score, contact surface area was a better predictor of functional change after partial nephrectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Dual-joint modeling for estimation of total knee replacement contact forces during locomotion.

    Science.gov (United States)

    Hast, Michael W; Piazza, Stephen J

    2013-02-01

    Model-based estimation of in vivo contact forces arising between components of a total knee replacement is challenging because such forces depend upon accurate modeling of muscles, tendons, ligaments, contact, and multibody dynamics. Here we describe an approach to solving this problem with results that are tested by comparison to knee loads measured in vivo for a single subject and made available through the Grand Challenge Competition to Predict in vivo Tibiofemoral Loads. The approach makes use of a "dual-joint" paradigm in which the knee joint is alternately represented by (1) a ball-joint knee for inverse dynamic computation of required muscle controls and (2) a 12 degree-of-freedom (DOF) knee with elastic foundation contact at the tibiofemoral and patellofemoral articulations for forward dynamic integration. Measured external forces and kinematics were applied as a feedback controller and static optimization attempted to track measured knee flexion angles and electromyographic (EMG) activity. The resulting simulations showed excellent tracking of knee flexion (average RMS error of 2.53 deg) and EMG (muscle activations within ±10% envelopes of normalized measured EMG signals). Simulated tibiofemoral contact forces agreed qualitatively with measured contact forces, but their RMS errors were approximately 25% of the peak measured values. These results demonstrate the potential of a dual-joint modeling approach to predict joint contact forces from kinesiological data measured in the motion laboratory. It is anticipated that errors in the estimation of contact force will be reduced as more accurate subject-specific models of muscles and other soft tissues are developed.

  2. Label free imaging of cell-substrate contacts by holographic total internal reflection microscopy.

    Science.gov (United States)

    Mandracchia, Biagio; Gennari, Oriella; Marchesano, Valentina; Paturzo, Melania; Ferraro, Pietro

    2017-09-01

    The study of cell adhesion contacts is pivotal to understand cell mechanics and interaction at substrates or chemical and physical stimuli. We designed and built a HoloTIR microscope for label-free quantitative phase imaging of total internal reflection. Here we show for the first time that HoloTIR is a good choice for label-free study of focal contacts and of cell/substrate interaction as its sensitivity is enhanced in comparison with standard TIR microscopy. Finally, the simplicity of implementation and relative low cost, due to the requirement of less optical components, make HoloTIR a reasonable alternative, or even an addition, to TIRF microscopy for mapping cell/substratum topography. As a proof of concept, we studied the formation of focal contacts of fibroblasts on three substrates with different levels of affinity for cell adhesion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Identifying sensitive areas on intercultural contacts: An exploratory study

    Directory of Open Access Journals (Sweden)

    Ignacio Ramos-Vidal

    2011-06-01

    Full Text Available This paper analyzes the negative influence that cultural friction areas can promote on intercultural contacts. First, we expose the critical incident method like cross-cultural training model (Arthur, 2001. Then we show the negative effects that sensitive cultural zones can exert on the formation of prejudices and stereotypes about culturally diverse groups, analyzing 77 critical incidents collected in two different formative contexts. The main cultural shock areas detected are a intercultural communication barriers, b gender roles, and c the cultural expressions statement. Strategies to improve the method validity are proposed.

  4. Quantitative assessment and prediction of the contact area development during spherical tip indentation of glassy polymers.

    NARCIS (Netherlands)

    Pelletier, C.G.N.; Toonder, den J.M.J.; Govaert, L.E.; Hakiri, N.; Sakai, M.

    2008-01-01

    This paper describes the development of the contact area during indentation of polycarbonate. The contact area was measured in situ using an instrumented indentation microscope and compared with numerical simulations using an elasto-plastic constitutive model. The parameters in the model were

  5. Rubber friction: The contribution from the area of real contact.

    Science.gov (United States)

    Tiwari, A; Miyashita, N; Espallargas, N; Persson, B N J

    2018-06-14

    There are two contributions to the friction force when a rubber block is sliding on a hard and rough substrate surface, namely, a contribution F ad = τ f A from the area of real contact A and a viscoelastic contribution F visc from the pulsating forces exerted by the substrate asperities on the rubber block. Here we present experimental results obtained at different sliding speeds and temperatures, and we show that the temperature dependency of the shear stress τ f , for temperatures above the rubber glass transition temperature T g , is weaker than that of the bulk viscoelastic modulus. The physical origin of τ f for T > T g is discussed, and we propose that its temperature dependency is determined by the rubber molecule segment mobility at the sliding interface, which is higher than in the bulk because of increased free-volume effect due to the short-wavelength surface roughness. This is consistent with the often observed reduction in the glass transition temperature in nanometer-thick surface layers of glassy polymers. For temperatures T contact regions and the contact area is determined by the rubber penetration hardness. For this case, we propose that the frictional shear stress is due to slip at the interface between the rubber and a transfer film adsorbed on the concrete surface.

  6. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Effect of difference in occlusal contact area of mandibular free-end edentulous area implants on periodontal mechanosensitive threshold of adjacent premolars.

    Science.gov (United States)

    Terauchi, Rie; Arai, Korenori; Tanaka, Masahiro; Kawazoe, Takayoshi; Baba, Shunsuke

    2015-01-01

    Implant treatment is believed to cause minimal invasion of remaining teeth. However, few studies have examined teeth adjacent to an implant region. Therefore, this study investigated the effect of occlusal contact size of implants on the periodontal mechanosensitive threshold of adjacent premolars. A cross-sectional study design was adopted. The Department of Oral Implantology, Osaka Dental University, was the setting where patients underwent implant treatment in the mandibular free-end edentulous area. The study population comprised of 87 patients (109 teeth) who underwent follow-up observation for at least 3 years following implant superstructure placement. As variables, age, sex, duration following superstructure placement, presence or absence of dental pulp, occlusal contact area, and periodontal mechanosensitive threshold were considered. The occlusal contact area was measured using Blue Silicone(®)and Bite Eye BE-I(®). Periodontal mechanosensitive threshold were measured using von Frey hair. As quantitative variables for periodontal mechanosensitive threshold, we divided subjects into two groups: normal (≤5 g) and high (≥5.1 g). For statistical analysis, we compared the two groups for the sensation thresholds using the Chi square test for categorical data and the Mann-Whitney U test for continuous volume data. For variables in which a significant difference was noted, we calculated the odds ratio (95 % confidence interval) and the effective dose. There were 93 teeth in the normal group and 16 teeth in the high group based on periodontal mechanosensitive threshold. Comparison of the two groups indicated no significant differences associated with age, sex, duration following superstructure placement, or presence or absence of dental pulp. A significant difference was noted with regard to occlusal contact area, with several high group subjects belonging to the small contact group (odds ratio: 4.75 [1.42-15.87]; effective dose: 0.29). The results of

  8. The Effect of Pile-Up and Contact Area on Hardness Test by Nanoindentation

    Science.gov (United States)

    Miyake, Koji; Fujisawa, Satoru; Korenaga, Atsushi; Ishida, Takao; Sasaki, Shinya

    2004-07-01

    We used atomic force microscopy (AFM) for the indentation test evaluating the indentation hardness of materials in the nanometer range. BK7, fused silica, and single-crystal silicon were used as test sample materials. The data analysis processes used to determine the contact area were important in evaluating the indentation hardness of the materials. The direct measurement of the size of the residual hardness impression was useful in evaluating the contact area even in the nanometer region. The results led us to conclude that AFM indentation using a sharp indenter is a powerful method for estimating the indentation hardness in the nanometer range.

  9. Investigation of force, contact area, and dwell time in finger-tapping tasks on membrane touch interface.

    Science.gov (United States)

    Liu, Na; Yu, Ruifeng

    2018-06-01

    This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area, and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area, and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area, and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives.

  10. VoroMQA: Assessment of protein structure quality using interatomic contact areas.

    Science.gov (United States)

    Olechnovič, Kliment; Venclovas, Česlovas

    2017-06-01

    In the absence of experimentally determined protein structure many biological questions can be addressed using computational structural models. However, the utility of protein structural models depends on their quality. Therefore, the estimation of the quality of predicted structures is an important problem. One of the approaches to this problem is the use of knowledge-based statistical potentials. Such methods typically rely on the statistics of distances and angles of residue-residue or atom-atom interactions collected from experimentally determined structures. Here, we present VoroMQA (Voronoi tessellation-based Model Quality Assessment), a new method for the estimation of protein structure quality. Our method combines the idea of statistical potentials with the use of interatomic contact areas instead of distances. Contact areas, derived using Voronoi tessellation of protein structure, are used to describe and seamlessly integrate both explicit interactions between protein atoms and implicit interactions of protein atoms with solvent. VoroMQA produces scores at atomic, residue, and global levels, all in the fixed range from 0 to 1. The method was tested on the CASP data and compared to several other single-model quality assessment methods. VoroMQA showed strong performance in the recognition of the native structure and in the structural model selection tests, thus demonstrating the efficacy of interatomic contact areas in estimating protein structure quality. The software implementation of VoroMQA is freely available as a standalone application and as a web server at http://bioinformatics.lt/software/voromqa. Proteins 2017; 85:1131-1145. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    OpenAIRE

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization ...

  12. Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

    Science.gov (United States)

    Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim

    2013-08-26

    Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only

  13. The effect of body postures on the distribution of air gap thickness and contact area.

    Science.gov (United States)

    Mert, Emel; Psikuta, Agnes; Bueno, Marie-Ange; Rossi, René M

    2017-02-01

    The heat and mass transfer in clothing is predominantly dependent on the thickness of air layer and the magnitude of contact area between the body and the garment. The air gap thickness and magnitude of the contact area can be affected by the posture of the human body. Therefore, in this study, the distribution of the air gap and the contact area were investigated for different body postures of a flexible manikin. In addition, the effect of the garment fit (regular and loose) and style (t-shirts, sweatpants, jacket and trousers) were analysed for the interaction between the body postures and the garment properties. A flexible manikin was scanned using a three-dimensional (3D) body scanning technique, and the scans were post-processed in dedicated software. The body posture had a strong effect on the air gap thickness and the contact area for regions where the garment had a certain distance from the body. Furthermore, a mathematical model was proposed to estimate the possible heat transfer coefficient for the observed air layers and their change with posture. The outcome of this study can be used to improve the design of the protective and functional garments and predict their effect on the human body.

  14. Excitable waves at the margin of the contact area between a cell and a substrate

    International Nuclear Information System (INIS)

    Ali, O; Albigès-Rizo, C; Block, M R; Fourcade, B

    2009-01-01

    In this paper, we study a new physical mechanism to generate an activator field which signals the extreme margin of the contact area between an adherent cell and the substrate. This mechanism is based on the coupling between the adhesive bridges connecting the substrate to the cytoskeleton and a cytosolic activator. Once activated by adhesion on the adhesive bridges, this activator is free to diffuse on the membrane. We propose that this activator is part of the mecano-transduction pathway which links adhesion to actin polymerization and, thus, to cellular motility. The consequences of our model are as follows: (a) the activator is localized at the rim of the contact area, (b) the adhesion is reinforced at the margin of the contact area between the cell and the substrate, (c) excitable waves of the activator can propagate along the adhesion rim

  15. Three-dimensional in vivo patellofemoral kinematics and contact area of anterior cruciate ligament-deficient and -reconstructed subjects using magnetic resonance imaging.

    Science.gov (United States)

    Shin, Choongsoo S; Carpenter, R Dana; Majumdar, Sharmila; Ma, C Benjamin

    2009-11-01

    The purpose of this study was to test whether (1) the 3-dimensional in vivo patellofemoral kinematics and patellofemoral contact area of anterior cruciate ligament (ACL)-deficient knees are different from those of normal, contralateral knees and (2) ACL reconstruction restores in vivo patellofemoral kinematics and contact area. Ten ACL-deficient knees and twelve ACL-reconstructed knees, as well as the contralateral uninjured knees, were tested. Magnetic resonance imaging was performed at full extension and 40 degrees of flexion under simulated partial weight-bearing conditions. Six-degrees of freedom patellofemoral kinematics, patellofemoral contact area, and contact location were analyzed by use of magnetic resonance image-based 3-dimensional patellofemoral knee models. The patella in the ACL-deficient knees underwent significantly more lateral tilt during flexion (P contact areas of ACL-deficient knees at both the extended and flexed positions (37 +/- 22 mm(2) and 357 +/- 53 mm(2), respectively) were significantly smaller than those of contralateral knees (78 +/- 45 mm(2) and 437 +/- 119 mm(2), respectively) (P contact area of ACL-reconstructed knees in the extended position (86 +/- 41 mm(2)) was significantly larger (P contact centroid translation, and contact area showed coefficients of variation of less than 6.8%. ACL injuries alter patellofemoral kinematics including patellar tilt and patellar lateral translation, but ACL reconstruction with hamstring or allograft restores altered patellar tilt. ACL injuries reduce the patellofemoral contact area at both the extended and flexed positions, but ACL reconstruction enlarges the patellofemoral contact area at extension and restores the normal contact area at low angles of flexion. Level III, case-control study.

  16. Technical Note: Validation of two methods to determine contact area between breast and compression paddle in mammography

    NARCIS (Netherlands)

    Branderhorst, Woutjan; de Groot, Jerry E.; van Lier, Monique G. J. T. B.; Highnam, Ralph P.; den Heeten, Gerard J.; Grimbergen, Cornelis A.

    2017-01-01

    Purpose: To assess the accuracy of two methods of determining the contact area between the compression paddle and the breast in mammography. An accurate method to determine the contact area is essential to accurately calculate the average compression pressure applied by the paddle. Methods: For a

  17. A Numerical Study of Effects of the Manufacture Perturbations to Contacts of the Total Hip Replacement

    Czech Academy of Sciences Publication Activity Database

    Koukal, M.; Fuis, Vladimír; Florian, Z.; Janíček, P.

    2011-01-01

    Roč. 18, č. 1 (2011), s. 33-42 ISSN 1802-1484 Institutional research plan: CEZ:AV0Z20760514 Keywords : total hip replacement * FEM * roundness * contact pressure * frictional moment Subject RIV: BO - Biophysics

  18. Simultaneous measurement of eye stiffness and contact area for living human eyes.

    Science.gov (United States)

    Kurita, Yuichi; Iida, Yoshichika; Kaneko, Makoto; Mishima, Hiromu K; Katakura, Seiki; Kiuchi, Yoshiaki

    2007-01-01

    Goldmann applanation tonometry is commonly used for measuring IOP (IntraOcular Pressure) to diagnose glaucoma. However, the measured IOP by the applanation tonometry is valid only under the assumption that all the subjects have the same structural eye stiffness. Abnormal eye stiffness makes abnormal corneal deformation and thus the current applanation tonometer misestimates the IOP. This study challenges to measure the eye stiffness in vivo with a non-invasive approach for detecting the abnormal deformation. The deformation of the cornea and the contact area between the probe and the cornea are simultaneously captured by cameras during the experiment. Experimental results show that some subjects have different relationship among the force, the displacement and the contact area even with same IOP. The proposed eye stiffness measurement can help detecting the abnormal deformation and the eyes with misestimated IOP.

  19. Hardness and posting of foot orthoses modify plantar contact area, plantar pressure, and perceived comfort when cycling.

    Science.gov (United States)

    Bousie, Jaquelin A; Blanch, Peter; McPoil, Thomas G; Vicenzino, Bill

    2018-07-01

    To evaluate the effects of hardness and posting of orthoses on plantar profile and perceived comfort and support during cycling. A repeated measures study with randomised order of orthoses, hardness, and posting conditions. Twenty-three cyclists cycled at a cadence of 90rpm and a perceived exertion rating of twelve. Contoured soft and hard orthoses with or without a medial forefoot or lateral forefoot post were evaluated. Plantar contact area, mean pressure and peak pressure were measured for nine plantar regions using the pedar ® -X system and represented as a percentage of the total (CA%, MP%, and PP% respectively). Perceived comfort and support was rated on a visual analogue scale. The softer orthosis significantly increased CA% (p=0.014) across the midfoot and heel with a decrease in the toe region and forefoot. MP% (p=0.034) and PP% (p=0.012) were significantly increased at the mid and lateral forefoot with reductions in MP% at the midfoot and in PP% at the hallux and toes. Forefoot posting significantly increased CA% (p=0.018) at the toes and forefoot and decreased it at the heel. PP% was significantly altered (p=0.013) based on posting position. Lateral forefoot posting significantly decreased heel comfort (p=0.036). When cycling, a soft, contoured orthosis increased contact across the midfoot and heel, modulating forefoot and midfoot plantar pressures but not altering comfort or support. Forefoot postings significantly modified contact areas and plantar pressures and reduced comfort at the heel. Copyright © 2017. Published by Elsevier Ltd.

  20. [Measurements of tibio-femoral contact area after experimental partial and subtotal meniscectomie (author's transl)].

    Science.gov (United States)

    Hehne, H J; Riede, U N; Hauschild, G; Schlageter, M

    1981-02-01

    By means of section material, 24 partial and 58 subtotal meniscectomies were performed and the loss of tibio-femoral contact was evaluated by the Touchier-method planimetrically. In cases of partial resection this loss was 12% only, where as in subtotal resection 46%, where by the remaining contact zones lay in the central-, anyway meniscusfree area. The diagram of the chondral splitting lines showed a maximum of compression here, consecutively the remaining contact zone is reduced to the in earlier times most affected cartilage areas. The result correlates to the appearance of chondromalacies of the central tibial plateau in our own section cases and of postoperative osteoarthritis after subtotal meniscectomies in literature. Subtotal meniscectomies lead to incongruence and increased pressure. a pseudo-regeneration seems not to compensate the meniscus function sufficiently. A result for the clinic one should, when possible, resect menisci only partially.

  1. Effect of solution and leaf surface polarity on droplet spread area and contact angle.

    Science.gov (United States)

    Nairn, Justin J; Forster, W Alison; van Leeuwen, Rebecca M

    2016-03-01

    How much an agrochemical spray droplet spreads on a leaf surface can significantly influence efficacy. This study investigates the effect solution polarity has on droplet spreading on leaf surfaces and whether the relative leaf surface polarity, as quantified using the wetting tension dielectric (WTD) technique, influences the final spread area. Contact angles and spread areas were measured using four probe solutions on 17 species. Probe solution polarity was found to affect the measured spread area and the contact angle of the droplets on non-hairy leaves. Leaf hairs skewed the spread area measurement, preventing investigation of the influence of surface polarity on hairy leaves. WTD-measured leaf surface polarity of non-hairy leaves was found to correlate strongly with the effect of solution polarity on spread area. For non-polar leaf surfaces the spread area decreases with increasing solution polarity, for neutral surfaces polarity has no effect on spread area and for polar leaf surfaces the spread area increases with increasing solution polarity. These results attest to the use of the WTD technique as a means to quantify leaf surface polarity. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  2. Prediction of bead area contact load at the tire-wheel interface using NASTRAN

    Science.gov (United States)

    Chen, C. H. S.

    1982-01-01

    The theoretical prediction of the bead area contact load at the tire wheel interface using NASTRAN is reported. The application of the linear code to a basically nonlinear problem results in excessive deformation of the structure and the tire-wheel contact conditions become impossible to achieve. A psuedo-nonlinear approach was adopted in which the moduli of the cord reinforced composite are increased so that the computed key deformations matched that of the experiment. Numerical results presented are discussed.

  3. Intraoral versus extraoral measurement of the height of the interproximal contact area in maxillary anterior teeth.

    Science.gov (United States)

    Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K

    2015-01-01

    This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.

  4. Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

    Science.gov (United States)

    Leumann, Andre; Fortuna, Rafael; Leonard, Tim; Valderrabano, Victor; Herzog, Walter

    2015-01-01

    The menisci are thought to modulate load transfer and to absorb shocks in the knee joint. No study has experimentally measured the meniscal functions in the intact, in vivo joint loaded by physiologically relevant muscular contractions. Right knee joints of seven New Zealand white rabbits were loaded using isometric contractions of the quadriceps femoris muscles controlled by femoral nerve stimulation. Isometric knee extensor torques at the maximal and two submaximal force levels were performed at knee angles of 70°, 90°, 110°, and 130°. Patellofemoral and tibiofemoral contact areas and pressure distributions were measured using Fuji Presensor film inserted above and below the menisci and also with the menisci removed. Meniscectomy was associated with a decrease in tibiofemoral contact area ranging from 30 to 70% and a corresponding increase in average contact pressures. Contact areas measured below the menisci were consistently larger than those measured on top of the menisci. Contact areas in the patellofemoral joint (PFJ), and peak pressures in tibiofemoral and PFJs, were not affected by meniscectomy. Contact areas and peak pressures in all joints depended crucially on knee joint angle and quadriceps force: The more flexed the knee joint was, the larger were the contact areas and the higher were the peak pressures. In agreement with the literature, removal of the menisci was associated with significant decreases in tibiofemoral contact area and corresponding increases in average contact pressures, but surprisingly, peak pressures remained unaffected, indicating that the function of the menisci is to distribute loads across a greater contact area.

  5. Electrokinetic desalination of protruded areas of stone avoiding the direct contact with electrodes

    DEFF Research Database (Denmark)

    Feijoo, J.; Matyscák, O.; Ottosen, Lisbeth M.

    2017-01-01

    of the sandstone highly contaminated with salts. Therefore, these results confirmed that it was possible to desalinate the sandstone using electrokinetic methods without the need to put in contact the affected areas with the equipment, reducing the possibility of altering it by manipulation.......Soluble salts are considered one of the main deterioration factors of porous building materials such as rocks, bricks or granites. The desalination treatments currently used in order to mitigate this alteration process are usually applied directly on the affected areas, which have often a low...... degree of cohesion precisely due to the deteriorating effect of the salts. The present study aimed to investigate the evaluation of a new approach based on electrokinetic techniques to desalinate rocks in monuments, specifically to desalinate carved reliefs. The procedure avoids the direct contact...

  6. Axoglial contacts in the area postrema of the cat - An ultrastructural study

    Science.gov (United States)

    Damelio, Fernando E.; Gibbs, Michael A.; Mehler, William R.; Philpott, Delbert E.; Savage, Wayne

    1986-01-01

    Axoglial contacts were observed in an ultrastructural study of the area postrema of the cat. According to the disposition of the electron-dense projections attached to the adjoining membranes these contacts were classified as symmetrical or asymmetrical. The axon profiles contained aggregations of clear vesicles randomly distributed or grouped in clusters adjacent to the electron-dense projections. Dense core vesicles were occasionally seen. The neuroglial profiles were either astrocytic or ependymoglial in nature. The astrocytes showed a clear cytoplasm, polymorphous vesicles, mitochondria, glycogen granules, and bundles of filaments. The ependymal cells, in contrast, had a more electron-dense and granular appearance, tubular structures, irregular vesicular formations, profiles of smooth reticuloendoplasm, and filaments grouped in bundles or isolated in the cytoplasm. The possibility that these contacts might play a role in the chemical transfer from neurons to glial cells is discussed on the basis of existing biochemical data.

  7. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living.

    Science.gov (United States)

    Yoshida, H; Faust, A; Wilckens, J; Kitagawa, M; Fetto, J; Chao, Edmund Y-S

    2006-01-01

    Estimation of the hip joint contact area and pressure distribution during activities of daily living is important in predicting joint degeneration mechanism, prosthetic implant wear, providing biomechanical rationales for preoperative planning and postoperative rehabilitation. These biomechanical data were estimated utilizing a generic hip model, the Discrete Element Analysis technique, and the in vivo hip joint contact force data. The three-dimensional joint potential contact area was obtained from the anteroposterior radiograph of a subject and the actual joint contact area and pressure distribution in eight activities of daily living were calculated. During fast, normal, and slow walking, the peak pressure of moderate magnitude was located at the lateral roof of the acetabulum during mid-stance. In standing up and sitting down, and during knee bending, the peak pressures were located at the edge of the posterior horn and the magnitude of the peak pressure during sitting down was 2.8 times that of normal walking. The peak pressure was found at the lateral roof in climbing up stairs which was higher than that in going down stairs. These results can be used to rationalize rehabilitation protocols, functional restrictions after complex acetabular reconstructions, and prosthetic component wear and fatigue test set up. The same model and analysis can provide further insight to soft tissue loading and pathology such as labral injury. When the pressure distribution on the acetabulum is inverted onto the femoral head, prediction of subchondral bone collapse associated with avascular necrosis can be achieved with improved accuracy.

  8. AFM-based tribological study of nanopatterned surfaces: the influence of contact area instabilities.

    Science.gov (United States)

    Rota, A; Serpini, E; Gazzadi, G C; Valeri, S

    2016-04-06

    Although the importance of morphology on the tribological properties of surfaces has long been proved, an exhaustive understanding of nanopatterning effects is still lacking due to the difficulty in both fabricating 'really nano-' structures and detecting their tribological properties. In the present work we show how the probe-surface contact area can be a critical parameter due to its remarkable local variability, making a correct interpretation of the data very difficult in the case of extremely small nanofeatures. Regular arrays of parallel 1D straight nanoprotrusions were fabricated by means of a low-dose focused ion beam, taking advantage of the amorphization-related swelling effect. The tribological properties of the patterns were detected in the presence of air and in vacuum (dry ambient) by atomic force microscopy. We have introduced a novel procedure and data analysis to reduce the uncertainties related to contact instabilities. The real time estimation of the radius of curvature of the contacting asperity enables us to study the dependence of the tribological properties of the patterns from their geometrical characteristics. The effect of the patterns on both adhesion and the coefficient of friction strongly depends on the contact area, which is linked to the local radius of curvature of the probe. However, a detectable hydrophobic character induced on the hydrophilic native SiO2 has been observed as well. The results suggest a scenario for capillary formation on the patterns.

  9. AFM-based tribological study of nanopatterned surfaces: the influence of contact area instabilities

    International Nuclear Information System (INIS)

    Rota, A; Serpini, E; Gazzadi, G C; Valeri, S

    2016-01-01

    Although the importance of morphology on the tribological properties of surfaces has long been proved, an exhaustive understanding of nanopatterning effects is still lacking due to the difficulty in both fabricating ‘really nano-’ structures and detecting their tribological properties. In the present work we show how the probe–surface contact area can be a critical parameter due to its remarkable local variability, making a correct interpretation of the data very difficult in the case of extremely small nanofeatures. Regular arrays of parallel 1D straight nanoprotrusions were fabricated by means of a low-dose focused ion beam, taking advantage of the amorphization-related swelling effect. The tribological properties of the patterns were detected in the presence of air and in vacuum (dry ambient) by atomic force microscopy. We have introduced a novel procedure and data analysis to reduce the uncertainties related to contact instabilities. The real time estimation of the radius of curvature of the contacting asperity enables us to study the dependence of the tribological properties of the patterns from their geometrical characteristics. The effect of the patterns on both adhesion and the coefficient of friction strongly depends on the contact area, which is linked to the local radius of curvature of the probe. However, a detectable hydrophobic character induced on the hydrophilic native SiO 2 has been observed as well. The results suggest a scenario for capillary formation on the patterns. (paper)

  10. On the Influence of Clearance in Orthotropic Disc-Pin Contacts

    DEFF Research Database (Denmark)

    Pedersen, Pauli

    2007-01-01

    , an orthotropic disc-pin contact problem. The most simple solutions are named Hertz solutions (from 1882), and we use one of these solutions for comparison with finite element results. As a function of the total contact force we find (inversely) the size of the contact area, the distribution of the contact......Solutions to contact problems are important in mechanical as well as in civil engineering, and even for the most simple problems there is still a need for research results. In the present paper we use an alternative super element procedure to solve directly, without iteration and incrementation...... pressure, and the contact compliance. In models of finite size the compliance depends on the flexibility of the total model, including the boundary condition of the model, and therefore disagreement with the locally based analytical models is expected. The examples of an earlier paper were restricted...

  11. Wound healing: total contact cast vs. custom-made temporary footwear for patients with diabetic foot ulceration

    NARCIS (Netherlands)

    van der Weg, F.B.; van der Windt, D.A.W.M.; Vahl, A.C.

    2008-01-01

    The objective of this study was to compare the effectiveness of irremovable total-contact casts (TCC) and custom-made temporary footwear (CTF) to heal neuropathic foot ulcerations in individuals with diabetes. In this prospective clinical trial, 43 patients with plantar ulcer Grade 1 or 2 (Wagner

  12. High-frequency imaging of elastic contrast and contact area with implications for naturally observed changes in fault properties

    Science.gov (United States)

    Nagata, Kohei; Kilgore, Brian D.; Beeler, Nicholas M.; Nakatani, Masao

    2014-01-01

    During localized slip of a laboratory fault we simultaneously measure the contact area and the dynamic fault normal elastic stiffness. One objective is to determine conditions where stiffness may be used to infer changes in area of contact during sliding on nontransparent fault surfaces. Slip speeds between 0.01 and 10 µm/s and normal stresses between 1 and 2.5 MPa were imposed during velocity step, normal stress step, and slide-hold-slide tests. Stiffness and contact area have a linear interdependence during rate stepping tests and during the hold portion of slide-hold-slide tests. So long as linearity holds, measured fault stiffness can be used on nontransparent materials to infer changes in contact area. However, there are conditions where relations between contact area and stiffness are nonlinear and nonunique. A second objective is to make comparisons between the laboratory- and field-measured changes in fault properties. Time-dependent changes in fault zone normal stiffness made in stress relaxation tests imply postseismic wave speed changes on the order of 0.3% to 0.8% per year in the two or more years following an earthquake; these are smaller than postseismic increases seen within natural damage zones. Based on scaling of the experimental observations, natural postseismic fault normal contraction could be accommodated within a few decimeter wide fault core. Changes in the stiffness of laboratory shear zones exceed 10% per decade and might be detectable in the field postseismically.

  13. An examination of the interparticle contact area during sintering of W-0.3 wt pct Co

    International Nuclear Information System (INIS)

    Mitlin, D.; German, R.M.

    1998-01-01

    As a powder compact sinters, its microstructure evolves. One way to quantify the scale of the microstructure is to consider the interparticle contact area. This study examines two known models for calculating the interparticle contact area: the classic two-sphere model and the Voronoi cell model. Both models have particular assumptions about the microstructure that make them not applicable for treating densification to near full density with concurrent grain growth. The classic two-sphere model assumes a regular packing of particles and a perfectly spherical particle geometry and neglects an increasing particle coordination number with sintering. The Voronoi cell model assumes that the scale of the microstructure remains constant; i.e., as long as the compact is densifying, grain growth does not occur. The authors propose a modified Voronoi cell that accounts for an increasing grain size, making it applicable to a general case where grain growth occurs during sintering. The three models are compared to the interparticle contact area data, obtained by stereology techniques, for W-0.3 wt pct Co sintered from green state to near full density. The original Voronoi cell model fits the data only at low temperatures, before the onset of grain growth. Below approximately 90 pct relative density, the two-sphere model with an assumed coordination number of six (coordination number in a green compact) and the modified Voronoi cell model provide a good fit to the data. At higher densities, both models overestimate the interparticle contact area

  14. Silicide-to-silicon specific contact resistance characterization

    NARCIS (Netherlands)

    Stavitski, N.

    2009-01-01

    The performance of Si integrated circuits depends on the transistor drive current. The drive current of a MOS transistor is determined by the total device resistance, which consists of the channel resistance and the parasitic resistances associated with dopant diffusion areas and contacts. It is

  15. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II program we propose to develop a manufacturable production process to introduce backside contacts to MicroLink Devices? large-area, multi-junction...

  16. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I program we propose to develop an innovative fabrication process to introduce backside contacts to MicroLink Devices' large-area, multi-junction...

  17. Modelling of real area of contact between tool and workpiece in metal forming processes including the influence of subsurface deformation

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Martins, Paulo A. F.; Bay, Niels Oluf

    2016-01-01

    New equipment for testing asperity deformation at various normal loads and subsurface elongations is presented. Resulting real contact area ratios increase heavily with increasing subsurface expansion due to lowered yield pressure on the asperities when imposing subsurface normal stress parallel ...... for estimating friction in the numerical modelling of metal forming processes.......New equipment for testing asperity deformation at various normal loads and subsurface elongations is presented. Resulting real contact area ratios increase heavily with increasing subsurface expansion due to lowered yield pressure on the asperities when imposing subsurface normal stress parallel...... to the surface. Finite element modelling supports the presentation and contributes by extrapolation of results to complete the mapping of contact area as function of normal pressure and one-directional subsurface strain parallel to the surface. Improved modelling of the real contact area is the basis...

  18. The influence of muscle pennation angle and cross-sectional area on contact forces in the ankle joint.

    Science.gov (United States)

    Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan Rt

    2017-01-01

    Data about a muscle's fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep

  19. Tear ascorbic acid levels and the total antioxidant status in contact lens wearers: A pilot study

    Directory of Open Access Journals (Sweden)

    Venkata Sai

    2009-01-01

    Full Text Available Aims: The tear ascorbate owing to its high concentration, functions as an effective antioxidant against the oxidative damage of cornea. Contact lens wearers (CLW are prone to oxidative stress due to the lens-induced hypoxic conditions. A pilot study was done to compare the tear ascorbic acid level and the total antioxidant capacity give as in normal and CLW. Materials and Methods: In this study 21 CLW (Mean age 23 ± 3 years ; M-2, F-19, who were daily wear users, with duration of wear not more than four years, along with age-matched 28 controls (Mean age 28 ± 3 ; M-15, F-13 were recruited in the study for collection of reflex tears using Schirmer′s strip. Ascorbic acid in tears was determined using high-performance liquid chromatography (HPLC, total antioxidant capacity (TAC and total protein assay by spectrophotometric analysis. Results: CLW showed no significant change in the tear ascorbic acid levels (0.4 ± 0.26 mM compared to the control subjects (0.61 ± 0.59 mM. The amount of ascorbic acid in tears did not correlate with the TAC or the total protein of the tears. The mean TAC in CLW was 0.69 ± 0.16 mM, with a total protein of 1.35 ± 0.46 mg/ml while in controls it was 0.7 ± 0.18 mM and 1.21 ± 0.47 mg/ml respectively . Conclusions: Soft contact lens wear did not show any significant change in tear ascorbic acid, TAC and total protein levels compared to controls.

  20. Analysis of contact pressure between the parts of total hip joint endoprosthesis with shape deviations

    Czech Academy of Sciences Publication Activity Database

    Fuis, Vladimír; Návrat, Tomáš; Hlavoň, Pavel; Koukal, M.; Houfek, Martin

    2007-01-01

    Roč. 40, č. 2 (2007), S558-S558 ISSN 0021-9290. [ISB 2007. Taipei, 01.07.2007-05.07.2007] R&D Projects: GA ČR GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : shape deviation * hip joint endoprosthesis * contact areas Subject RIV: BO - Biophysics Impact factor: 2.897, year: 2007

  1. Defining the value of injection current and effective electrical contact area for EGaIn-based molecular tunneling junctions.

    Science.gov (United States)

    Simeone, Felice C; Yoon, Hyo Jae; Thuo, Martin M; Barber, Jabulani R; Smith, Barbara; Whitesides, George M

    2013-12-04

    Analysis of rates of tunneling across self-assembled monolayers (SAMs) of n-alkanethiolates SCn (with n = number of carbon atoms) incorporated in junctions having structure Ag(TS)-SAM//Ga2O3/EGaIn leads to a value for the injection tunnel current density J0 (i.e., the current flowing through an ideal junction with n = 0) of 10(3.6±0.3) A·cm(-2) (V = +0.5 V). This estimation of J0 does not involve an extrapolation in length, because it was possible to measure current densities across SAMs over the range of lengths n = 1-18. This value of J0 is estimated under the assumption that values of the geometrical contact area equal the values of the effective electrical contact area. Detailed experimental analysis, however, indicates that the roughness of the Ga2O3 layer, and that of the Ag(TS)-SAM, determine values of the effective electrical contact area that are ~10(-4) the corresponding values of the geometrical contact area. Conversion of the values of geometrical contact area into the corresponding values of effective electrical contact area results in J0(+0.5 V) = 10(7.6±0.8) A·cm(-2), which is compatible with values reported for junctions using top-electrodes of evaporated Au, and graphene, and also comparable with values of J0 estimated from tunneling through single molecules. For these EGaIn-based junctions, the value of the tunneling decay factor β (β = 0.75 ± 0.02 Å(-1); β = 0.92 ± 0.02 nC(-1)) falls within the consensus range across different types of junctions (β = 0.73-0.89 Å(-1); β = 0.9-1.1 nC(-1)). A comparison of the characteristics of conical Ga2O3/EGaIn tips with the characteristics of other top-electrodes suggests that the EGaIn-based electrodes provide a particularly attractive technology for physical-organic studies of charge transport across SAMs.

  2. Evaluation of footprint contact area and pressure using a triple-row modification of the suture-bridge technique for rotator cuff repair.

    Science.gov (United States)

    Ostrander, Roger V; McKinney, Bart I

    2012-10-01

    Studies suggest that arthroscopic repair techniques may have high recurrence rates for larger rotator cuff tears. A more anatomic repair may improve the success rate when performing arthroscopic rotator cuff repair. We hypothesized that a triple-row modification of the suture-bridge technique for rotator cuff repair would result in significantly more footprint contact area and pressure between the rotator cuff and the humeral tuberosity. Eighteen ovine infraspinatus tendons were repaired using 1 of 3 simulated arthroscopic techniques: a double-row repair, the suture-bridge technique, and a triple-row repair. The triple-row repair technique is a modification of the suture-bridge technique that uses an additional reducing anchor between the medial and lateral rows. Six samples were tested per group. Pressure-indicating film was used to measure the footprint contact area and pressure after each repair. The triple-row repair resulted in significantly more rotator cuff footprint contact area and contact pressure compared with the double-row technique and the standard suture-bridge technique. No statistical difference in contact area or contact pressure was found between the double-row technique and the suture-bridge technique. The triple-row technique for rotator cuff repair results in significantly more footprint contact area and contact pressure compared with the double-row and standard suture-bridge techniques. This more anatomic repair may improve the healing rate when performing arthroscopic rotator cuff repair. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  3. Citation parameters of contact lens-related articles published in the ophthalmic literature.

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2014-09-01

    This study aimed at exploring the citation parameters of contact lenses articles published in the Ophthalmology thematic category of the Journal Citation Reports (JCR). The Thompson Reuters Web of Science database was accessed to record bibliometric information and citation parameters of all journals listed under the Ophthalmology area of the 2011 JCR edition, including the journals with main publication interests in the contact lens field. In addition, the same database was used to unveil all contact lens-related articles published in 2011 in the same thematic area, whereupon differences in citation parameters between those articles published in contact lens and non-contact lens-related journals were explored. Significant differences in some bibliometric indicators such as half-life and overall citation count were found between contact lens-related journals (shorter half-life and fewer citations) and the median values for the Ophthalmology thematic area of the JCR. Visual examination of all Ophthalmology journals uncovered a total of 156 contact lens-related articles, published in 28 different journals, with 27 articles each for Contact Lens & Anterior Eye, Eye & Contact Lens, and Optometry and Vision Science. Significant differences in citation parameters were encountered between those articles published in contact lens and non-contact lens source journals. These findings, which disclosed contact lenses to be a fertile area of research, may be of interest to researchers and institutions. Differences in bibliometric indicators are of relevance to avoid unwanted bias when conducting between- and within-discipline comparisons of articles, journals, and researchers.

  4. Chewing side, bite force symmetry, and occlusal contact area of subjects with different facial vertical patterns

    Directory of Open Access Journals (Sweden)

    Simone Guimarães Farias Gomes

    2011-10-01

    Full Text Available Craniofacial dimensions influence oral functions; however, it is not known whether they are associated with function asymmetry. The objective of this study was to evaluate chewing side preference and lateral asymmetry of occlusal contact area and bite force of individuals with different craniofacial patterns. Seventy-eight dentate subjects were divided into 3 groups according to the VERT index as follows: (1 mesofacial, (2 brachyfacial and (3 dolichofacial. Chewing side preference was evaluated using jaw tracking equipment, occlusal contact area was measured by silicon registration of posterior teeth, and bite force was measured unilaterally on molar regions using 2.25 mm-thick sensors. Statistical analysis was performed using ANOVA on Ranks, Student's t-test, and Mann-Whitney tests at a 5% significance level. Mesofacial, brachyfacial, and dolichofacial subjects presented more occlusal contact area on the left side. Only dolichofacial subjects showed lateral asymmetry for bite force, presenting higher force on the left side. No statistically significant differences were found for chewing side preference among all groups. Within the limitations of this study, it can be concluded that craniofacial dimensions play a role in asymmetry of bite force. ClinicalTrials.gov ID: NCT01286363.

  5. Constructal Optimization of Top Contact Metallization of a Photovoltaic Solar Cell

    OpenAIRE

    Bhakta, Aditya; Bandyopadhyay, Santanu

    2010-01-01

    A top contact metallization of a photovoltaic solar cell collects the current generated by incident solar radiation. Several power-loss mechanisms are associated with the current flow through the front contact grid. The design of the top metal contact grid is one of the most important areas of efficient photovoltaic solar cell design. In this paper, an approach based on the constructal theory is proposed to design the grid pattern in a photovoltaic solar cell, minimizing total resistive losse...

  6. What Governs Friction of Silicon Oxide in Humid Environment: Contact Area between Solids, Water Meniscus around the Contact, or Water Layer Structure?

    Science.gov (United States)

    Chen, Lei; Xiao, Chen; Yu, Bingjun; Kim, Seong H; Qian, Linmao

    2017-09-26

    In order to understand the interfacial parameters governing the friction force (F t ) between silicon oxide surfaces in humid environment, the sliding speed (v) and relative humidity (RH) dependences of F t were measured for a silica sphere (1 μm radius) sliding on a silicon oxide (SiO x ) surface, using atomic force microscopy (AFM), and analyzed with a mathematical model describing interfacial contacts under a dynamic condition. Generally, F t decreases logarithmically with increasing v to a cutoff value below which its dependence on interfacial chemistry and sliding condition is relatively weak. Above the cutoff value, the logarithmic v dependence could be divided into two regimes: (i) when RH is lower than 50%, F t is a function of both v and RH; (ii) in contrast, at RH ≥ 50%, F t is a function of v only, but not RH. These complicated v and RH dependences were hypothesized to originate from the structure of the water layer adsorbed on the surface and the water meniscus around the annulus of the contact area. This hypothesis was tested by analyzing F t as a function of the water meniscus area (A m ) and volume (V m ) estimated from a thermally activated water-bridge formation model. Surprisingly, it was found that F t varies linearly with V m and correlates poorly with A m at RH contact under ambient conditions.

  7. Technical Note: Validation of two methods to determine contact area between breast and compression paddle in mammography.

    Science.gov (United States)

    Branderhorst, Woutjan; de Groot, Jerry E; van Lier, Monique G J T B; Highnam, Ralph P; den Heeten, Gerard J; Grimbergen, Cornelis A

    2017-08-01

    To assess the accuracy of two methods of determining the contact area between the compression paddle and the breast in mammography. An accurate method to determine the contact area is essential to accurately calculate the average compression pressure applied by the paddle. For a set of 300 breast compressions, we measured the contact areas between breast and paddle, both capacitively using a transparent foil with indium-tin-oxide (ITO) coating attached to the paddle, and retrospectively from the obtained mammograms using image processing software (Volpara Enterprise, algorithm version 1.5.2). A gold standard was obtained from video images of the compressed breast. During each compression, the breast was illuminated from the sides in order to create a dark shadow on the video image where the breast was in contact with the compression paddle. We manually segmented the shadows captured at the time of x-ray exposure and measured their areas. We found a strong correlation between the manual segmentations and the capacitive measurements [r = 0.989, 95% CI (0.987, 0.992)] and between the manual segmentations and the image processing software [r = 0.978, 95% CI (0.972, 0.982)]. Bland-Altman analysis showed a bias of -0.0038 dm 2 for the capacitive measurement (SD 0.0658, 95% limits of agreement [-0.1329, 0.1252]) and -0.0035 dm 2 for the image processing software [SD 0.0962, 95% limits of agreement (-0.1921, 0.1850)]. The size of the contact area between the paddle and the breast can be determined accurately and precisely, both in real-time using the capacitive method, and retrospectively using image processing software. This result is beneficial for scientific research, data analysis and quality control systems that depend on one of these two methods for determining the average pressure on the breast during mammographic compression. © 2017 Sigmascreening B.V. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. Mapping the spatiotemporal evolution of solute transport in articular cartilage explants reveals how cartilage recovers fluid within the contact area during sliding.

    Science.gov (United States)

    Graham, Brian T; Moore, Axel C; Burris, David L; Price, Christopher

    2018-04-11

    The interstitial fluid within articular cartilage shields the matrix from mechanical stresses, reduces friction and wear, enables biochemical processes, and transports solutes into and out of the avascular extracellular matrix. The balanced competition between fluid exudation and recovery under load is thus critical to the mechanical and biological functions of the tissue. We recently discovered that sliding alone can induce rapid solute transport into buried cartilage contact areas via a phenomenon termed tribological rehydration. In this study, we use in situ confocal microscopy measurements to track the spatiotemporal propagation of a small neutral solute into the buried contact area to clarify the fluid mechanics underlying the tribological rehydration phenomenon. Sliding experiments were interrupted by periodic static loading to enable scanning of the entire contact area. Spatiotemporal patterns of solute transport combined with tribological data suggested pressure driven flow through the extracellular matrix from the contact periphery rather than into the surface via a fluid film. Interestingly, these testing interruptions also revealed dynamic, repeatable and history-independent fluid loss and recovery processes consistent with those observed in vivo. Unlike the migrating contact area, which preserves hydration by moving faster than interstitial fluid can flow, our results demonstrate that the stationary contact area can maintain and actively recover hydration through a dynamic competition between load-induced exudation and sliding-induced recovery. The results demonstrate that sliding contributes to the recovery of fluid and solutes by cartilage within the contact area while clarifying the means by which it occurs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Estimation of contact resistance in proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lianhong; Liu, Ying; Song, Haimin; Wang, Shuxin [School of Mechanical Engineering, Tianjin University, 92 Weijin Road, Nankai District, Tianjin 300072 (China); Zhou, Yuanyuan; Hu, S. Jack [Department of Mechanical Engineering, The University of Michigan, Ann Arbor, MI 48109-2125 (United States)

    2006-11-22

    The contact resistance between the bipolar plate (BPP) and the gas diffusion layer (GDL) is an important factor contributing to the power loss in proton exchange membrane (PEM) fuel cells. At present there is still not a well-developed method to estimate such contact resistance. This paper proposes two effective methods for estimating the contact resistance between the BPP and the GDL based on an experimental contact resistance-pressure constitutive relation. The constitutive relation was obtained by experimentally measuring the contact resistance between the GDL and a flat plate of the same material and processing conditions as the BPP under stated contact pressure. In the first method, which was a simplified prediction, the contact area and contact pressure between the BPP and the GDL were analyzed with a simple geometrical relation and the contact resistance was obtained by the contact resistance-pressure constitutive relation. In the second method, the contact area and contact pressure between the BPP and GDL were analyzed using FEM and the contact resistance was computed for each contact element according to the constitutive relation. The total contact resistance was then calculated by considering all contact elements in parallel. The influence of load distribution on contact resistance was also investigated. Good agreement was demonstrated between experimental results and predictions by both methods. The simplified prediction method provides an efficient approach to estimating the contact resistance in PEM fuel cells. The proposed methods for estimating the contact resistance can be useful in modeling and optimizing the assembly process to improve the performance of PEM fuel cells. (author)

  10. Mechanical Contact Experiments and Simulations

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Martins, P; Zhang, W.

    2011-01-01

    Mechanical contact is studied under dynamic development by means of a combined numerical and experimental investigation. The experiments are designed to allow dynamical development of non-planar contact areas with significant expansion in all three directions as the load is increased. Different....... The overall investigation serves for testing and validating the numerical implementation of the mechanical contact, which is one of the main contributions to a system intended for 3D simulation of resistance welding. Correct modelling of contact between parts to be welded, as well as contact with electrodes......, is crucial for satisfactory modelling of the resistance welding process. The resistance heating at the contact interfaces depends on both contact area and pressure, and as the contact areas develop dynamically, the presented tests are relevant for assessing the validity and accuracy of the mechanical contact...

  11. Wound healing: total contact cast vs. custom-made temporary footwear for patients with diabetic foot ulceration.

    Science.gov (United States)

    Van De Weg, F B; Van Der Windt, D A W M; Vahl, A C

    2008-03-01

    The objective of this study was to compare the effectiveness of irremovable total-contact casts (TCC) and custom-made temporary footwear (CTF) to heal neuropathic foot ulcerations in individuals with diabetes. In this prospective clinical trial, 43 patients with plantar ulcer Grade 1 or 2 (Wagner scale) were randomized to one of two off-loading modalities: TCC or CTF. Outcomes assessed were wound surface area reduction (cm2) and time to wound healing (days) at 2, 4, 8 and 16 weeks. To evaluate safety, possible side effects were recorded at each follow-up visit. The results showed no significant difference in wound surface area reduction (adjusted for baseline wound surface) at 2, 4, 8 or 16 weeks (adjusted mean difference 0.10 cm2; 95% CI -0.92-0.72 at 16 weeks). At 16 weeks, 12 patients had a completely healed ulcer, 6 per group. The median time to healing was shorter for the patients using a cast (52 vs. 90 days, p = 0.26). Five patients with TCC and two with CTF developed device-related complications. It was concluded that: (i) the rate of wound healing is not significantly different for patients treated with CTF or TCC. The difference in wound surface area was small and not significant at any time during follow-up; and (ii) the difference in healing time (38 days) may have attained statistical significance if the numbers in these sub-groups (2 x 6) had been higher. Since there appears to be little difference in effectiveness between both off-loading modalities, further investigation into the benefits of CTF is warranted.

  12. A pressure plate study on fore and hindlimb loading and the association with hoof contact area in sound ponies at the walk and trot.

    Science.gov (United States)

    Oosterlinck, M; Pille, F; Back, W; Dewulf, J; Gasthuys, F

    2011-10-01

    The aim of this study was to evaluate the association between fore- and hind-hoof contact area and limb loading. Data from a previous study on forelimb loading and symmetry were compared with data on hindlimb kinetics, and the fore- and hind-hoof contact area at the walk and trot was evaluated. Five sound ponies, selected for symmetrical feet, were walked and trotted over a pressure plate embedded in a custom-made runway. The hindlimb peak vertical force (PVF) and vertical impulse (VI) were found to be significantly lower than in the forelimb, whereas their high symmetry ratios (>95%) did not show a significant difference from forelimb data. Hindlimb PVF in ponies was found to be slightly higher when compared to data reported for horses even though the ponies moved at a similar or lower relative velocity. The contact area had low intra-individual variability and was significantly smaller in the hind- than in the fore-hooves. A larger contact area was significantly associated with lower peak vertical pressure (PVP) but higher PVF and VI. No significant differences between left and right sides were found for contact area or loading variables. Pressure plate measurements demonstrated a significant association between hoof contact area and limb loading, in addition to intrinsic differences between fore and hindlimb locomotor function. The pressure plate provides the clinician with a tool to quantify simultaneously contralateral differences in hoof contact area and limb loading. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Schottky Barrier Height of Pd/MoS2 Contact by Large Area Photoemission Spectroscopy.

    Science.gov (United States)

    Dong, Hong; Gong, Cheng; Addou, Rafik; McDonnell, Stephen; Azcatl, Angelica; Qin, Xiaoye; Wang, Weichao; Wang, Weihua; Hinkle, Christopher L; Wallace, Robert M

    2017-11-08

    MoS 2 , as a model transition metal dichalcogenide, is viewed as a potential channel material in future nanoelectronic and optoelectronic devices. Minimizing the contact resistance of the metal/MoS 2 junction is critical to realizing the potential of MoS 2 -based devices. In this work, the Schottky barrier height (SBH) and the band structure of high work function Pd metal on MoS 2 have been studied by in situ X-ray photoelectron spectroscopy (XPS). The analytical spot diameter of the XPS spectrometer is about 400 μm, and the XPS signal is proportional to the detection area, so the influence of defect-mediated parallel conduction paths on the SBH does not affect the measurement. The charge redistribution by Pd on MoS 2 is detected by XPS characterization, which gives insight into metal contact physics to MoS 2 and suggests that interface engineering is necessary to lower the contact resistance for the future generation electronic applications.

  14. Effects of low-density feeding on elk–fetus contact rates on Wyoming feedgrounds

    Science.gov (United States)

    Creech, Tyler G.; Cross, Paul C.; Scurlock, Brandon M.; Maichak, Eric J.; Rogerson, Jared D.; Henningsen, John C.; Creel, Scott

    2012-01-01

    High seroprevalance for Brucella abortus among elk on Wyoming feedgrounds suggests that supplemental feeding may influence parasite transmission and disease dynamics by altering the rate at which elk contact infectious materials in their environment. We used proximity loggers and video cameras to estimate rates of elk-to-fetus contact (the primary source of brucellosis transmission) during winter supplemental feeding. We compared contact rates during high-density and low-density (LD) feeding treatments that provided the same total amount of food distributed over different areas. Low-density feeding led to >70% reductions in total number of contacts and number of individuals contacting a fetus. Proximity loggers and video cameras provided similar estimates of elk–fetus contact rates. Elk contacted fetuses and random control points equally, suggesting that elk were not attracted to fetuses but encountered them incidentally while feeding. The modeled relationship between contact rate and disease prevalence is nonlinear and LD feeding may result in large reductions in brucellosis prevalence, but this depends on the amount of transmission that occurs on and off feedgrounds.

  15. The nature of electrical interaction of Schottky contacts

    International Nuclear Information System (INIS)

    Torkhov, N. A.

    2011-01-01

    Electrical interaction between metal-semiconductor contacts combined in a diode matrix with a Schottky barrier manifests itself in an appreciable variation in their surface potentials and static current-volt-characteristics. The necessary condition for appearance of electrical interaction between such contacts consists in the presence of a peripheral electric field (a halo) around them; this field propagates to a fairly large distances ( i,j ), concentration of doping impurities in the semiconductor N D , and physical nature of a metal-semiconductor system with a Schottky barrier (with the barrier height φ b ). It is established that bringing the contacts closer leads to a relative decrease in the threshold value of the “dead” zone in the forward current-voltage characteristics, an increase in the effective height of the barrier, and an insignificant increase in the nonideality factor. An increase in the total area of contacts (a total electric charge in the space charge region) in the matrix brings about an increase in the threshold value of the “dead” zone, a relative decrease in the effective barrier height, and an insignificant increase in the ideality factor.

  16. Comparing the occlusal contact area of individual teeth during low-level clenching.

    Science.gov (United States)

    Nishimori, Hideta; Iida, Takashi; Kamiyama, Hirona; Komoda, Yoshihiro; Obara, Ryoko; Uchida, Takashi; Kawara, Misao; Komiyama, Osamu

    2017-09-14

    The aim of this study was to investigate the occlusal contact area (OCA) in individual teeth during low-level tooth clenching in 24 healthy participants. Before measurements were made, the 100% maximum voluntary contraction (MVC) was determined. At baseline, all subjects were instructed to close their mouth and touch the opposing teeth with minimal force. Occlusal contact was recorded during three jaw motor tasks (baseline, 20% MVC, and 40% MVC) using a blue silicone material. OCA thickness was determined from images and defined on five levels: level 1 (0-149 µm), level 2 (0-89 µm), level 3 (0-49 µm), level 4 (0-29 µm), and level 5 (0-4 µm). Premolar and molar OCAs increased significantly from baseline to 20% MVC and 40% MVC. The OCA of each anterior tooth did not change significantly with increasing clenching intensity at all levels. Our findings suggest that premolar and molar OCAs may be altered by low-intensity clenching, affecting the teeth and periodontal tissues.

  17. Gas fireplace contact burns in young children.

    Science.gov (United States)

    Zettel, Julie C; Khambalia, Amina; Barden, Wendy; Murthy, Trisha; Macarthur, Colin

    2004-01-01

    Contact burns from domestic appliances are common in young children. Recently, gas fireplaces have been recognized as a potential cause of contact burns in young children. We sought to quantify the frequency of gas fireplace contact burns in young children, to identify the etiology of contact, to describe the clinical presentation, and to describe clinical outcomes. Children with gas fireplace contact burn injuries presenting to The Hospital for Sick Children in Toronto (1999-2002) were identified using three data sources: the Canadian Hospitals Injury Reporting and Prevention Program Database, the Burn Unit Registry, and the Rehabilitation Services Database. Demographic, clinical, and outcomes data were collected on all children. During the 4-year study period, 27 children presented to the hospital because of a gas fireplace contact burn (approximately 9% of all contact burns). The median age of the children was 14 months (range, 8-36 months), with 16 boys (59%). Most children were burned in their own home. With regard to etiology, 10 children (37%) lost their balance near the fireplace, 2 (7%) walked too close to the glass front, and 8 (30%) touched the glass front out of curiosity. Almost half (44%) of the children burned the palms and digits of both hands. The median total burn surface area was 1% (range, 0.2-2.5%). In total, 30% of children were admitted to hospital, and 11% required skin grafts. All children had full wound closure after 4 to 43 days. Given the etiology of these burns (loss of balance or curiosity), passive prevention, such as barriers or changes in the composition of glass panels, may be the most effective approach to combat them.

  18. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Two-year follow-up of changes in bite force and occlusal contact area after intraoral vertical ramus osteotomy with and without Le Fort I osteotomy.

    Science.gov (United States)

    Choi, Y J; Lim, H; Chung, C J; Park, K H; Kim, K H

    2014-06-01

    This study was performed to examine the longitudinal changes in bite force and occlusal contact area after mandibular setback surgery via intraoral vertical ramus osteotomy (IVRO). Patients with mandibular prognathism who underwent IVRO (surgical group: 39 men and 39 women) were compared with subjects with class I skeletal and dental relationships (control group; 32 men and 35 women). The surgical group was divided into two subgroups: 1-jaw surgery (n = 30) and 2-jaw surgery (n = 48). Bite force and contact area were measured in maximum intercuspation with the Dental Prescale System before treatment, within 1 month before surgery, and at 1, 3, 6, 9, 12, and 24 months postsurgery. A linear mixed model was used to investigate the time-dependent changes and associated factors. Bite force and contact area decreased during presurgical orthodontic treatment, were minimal at 1 month postsurgery, and increased gradually thereafter. The 1-jaw and 2-jaw subgroups showed no significant differences in bite force. The time-dependent changes in bite force were significantly different according to the contact area (P contact area gradually increase throughout the postsurgical evaluation period. Increasing the occlusal contact area may be essential for improving bite force after surgery. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

    Science.gov (United States)

    Inoue, Daisuke; Kabata, Tamon; Maeda, Toru; Kajino, Yoshitomo; Fujita, Kenji; Hasegawa, Kazuhiro; Yamamoto, Takashi; Takagi, Tomoharu; Ohmori, Takaaki; Tsuchiya, Hiroyuki

    2015-12-01

    It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant-femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.

  1. Are undesirable contact kinematics minimized after kinematically aligned total knee arthroplasty? An intersurgeon analysis of consecutive patients.

    Science.gov (United States)

    Howell, Stephen M; Hodapp, Esther E; Vernace, Joseph V; Hull, Maury L; Meade, Thomas D

    2013-10-01

    Tibiofemoral contact kinematics or knee implant motions have a direct influence on patient function and implant longevity and should be evaluated for any new alignment technique such as kinematically aligned total knee arthroplasty (TKA). Edge loading of the tibial liner and external rotation (reverse of normal) and adduction of the tibial component on the femoral component are undesirable contact kinematics that should be minimized. Accordingly, this study determined whether the overall prevalence of undesirable contact kinematics during standing, mid kneeling near 90 degrees and full kneeling with kinematically aligned TKA are minimal and not different between groups of consecutive patients treated by different surgeons. Three surgeons were asked to perform cemented, kinematically aligned TKA with patient-specific guides in a consecutive series of patients with their preferred cruciate-retaining (CR) implant. In vivo tibiofemoral contact positions were obtained using a 3- to 2-dimensional image registration technique in 69 subjects (Vanguard CR-TKA N = 22, and Triathlon CR-TKA N = 47). Anterior or posterior edge loading of the tibial liner was not observed. The overall prevalence of external rotation of the tibial component on the femoral component of 6 % was low and not different between surgeons (n.s.). The overall prevalence of adduction of the tibial component on the femoral component of 4 % was low and not different between surgeons (n.s.). Kinematically aligned TKA minimized the undesirable contact kinematics of edge loading of the tibial liner, and external rotation and adduction of the tibial component on the femoral component during standing and kneeling, which suggests an optimistic prognosis for durable long-term function. III.

  2. An approximate JKR solution for a general contact, including rough contacts

    Science.gov (United States)

    Ciavarella, M.

    2018-05-01

    In the present note, we suggest a simple closed form approximate solution to the adhesive contact problem under the so-called JKR regime. The derivation is based on generalizing the original JKR energetic derivation assuming calculation of the strain energy in adhesiveless contact, and unloading at constant contact area. The underlying assumption is that the contact area distributions are the same as under adhesiveless conditions (for an appropriately increased normal load), so that in general the stress intensity factors will not be exactly equal at all contact edges. The solution is simply that the indentation is δ =δ1 -√{ 2 wA‧ /P″ } where w is surface energy, δ1 is the adhesiveless indentation, A‧ is the first derivative of contact area and P‧‧ the second derivative of the load with respect to δ1. The solution only requires macroscopic quantities, and not very elaborate local distributions, and is exact in many configurations like axisymmetric contacts, but also sinusoidal waves contact and correctly predicts some features of an ideal asperity model used as a test case and not as a real description of a rough contact problem. The solution permits therefore an estimate of the full solution for elastic rough solids with Gaussian multiple scales of roughness, which so far was lacking, using known adhesiveless simple results. The result turns out to depend only on rms amplitude and slopes of the surface, and as in the fractal limit, slopes would grow without limit, tends to the adhesiveless result - although in this limit the JKR model is inappropriate. The solution would also go to adhesiveless result for large rms amplitude of roughness hrms, irrespective of the small scale details, and in agreement with common sense, well known experiments and previous models by the author.

  3. Single-row versus double-row capsulolabral repair: a comparative evaluation of contact pressure and surface area in the capsulolabral complex-glenoid bone interface.

    Science.gov (United States)

    Kim, Doo-Sup; Yoon, Yeo-Seung; Chung, Hoi-Jeong

    2011-07-01

    Despite the attention that has been paid to restoration of the capsulolabral complex anatomic insertion onto the glenoid, studies comparing the pressurized contact area and mean interface pressure at the anatomic insertion site between a single-row repair and a double-row labral repair have been uncommon. The purpose of our study was to compare the mean interface pressure and pressurized contact area at the anatomic insertion site of the capsulolabral complex between a single-row repair and a double-row repair technique. Controlled laboratory study. Thirty fresh-frozen cadaveric shoulders (mean age, 61 ± 8 years; range, 48-71 years) were used for this study. Two types of repair were performed on each specimen: (1) a single-row repair and (2) a double-row repair. Using pressure-sensitive films, we examined the interface contact area and contact pressure. The mean interface pressure was greater for the double-row repair technique (0.29 ± 0.04 MPa) when compared with the single-row repair technique (0.21 ± 0.03 MPa) (P = .003). The mean pressurized contact area was also significantly greater for the double-row repair technique (211.8 ± 18.6 mm(2), 78.4% footprint) compared with the single-row repair technique (106.4 ± 16.8 mm(2), 39.4% footprint) (P = .001). The double-row repair has significantly greater mean interface pressure and pressurized contact area at the insertion site of the capsulolabral complex than the single-row repair. The double-row repair may be advantageous compared with the single-row repair in restoring the native footprint area of the capsulolabral complex.

  4. Large area, low cost space solar cells with optional wraparound contacts

    Science.gov (United States)

    Michaels, D.; Mendoza, N.; Williams, R.

    1981-01-01

    Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

  5. The Risk of Depressive Disorder Among Contacts of Tuberculosis Patients in a TB-endemic Area

    Science.gov (United States)

    Pan, Sheng-Wei; Yen, Yung-Feng; Feng, Jia-Yih; Su, Vincent Yi-Fong; Kou, Yu Ru; Su, Wei-Juin

    2015-01-01

    Abstract Tuberculosis (TB) disease may be transmitted to close contacts of index cases, causing physical illness. No studies have investigated the risk of developing depressive disorder among TB contacts in a TB-endemic area. Adult participants with a new diagnosis of TB contact (ICD-9-CM codes V01.1 plus chest radiographic order) since January 1, 2008, were identified from the National Health Insurance Research Database in Taiwan. A control cohort matched for age (±5 y), sex, enrolled years, and income level was selected. These 2 cohorts were followed until December 31, 2012, and observed for the development of depressive disorder. The Kaplan-Meier method and the log-rank test were used to examine the difference in cumulative incidences of depressive disorder between groups. Cox proportional-hazard models were used to calculate adjusted hazard ratios (aHRs) for depressive disorder. The TB contact cohort consisted of 9046 patients and matched controls of 36,184 ones. The mean age of TB contacts was 44.7 years, and 56.0% of them were women. During a mean follow-up period of 2.5 years, 127 (1.40%) TB contacts and 521 (1.44%) matched controls developed depressive disorder. TB exposure was found to be an independent risk factor of depressive disorder in women (aHR 1.34, 95% confidence interval [CI] 1.07–1.68), but not in men (aHR 0.71, 95% CI 0.48–1.06) after adjusting for age, comorbidities, and income levels. The risk of depression was significantly higher for female TB contacts than for matched controls in the first and second years (aHR 1.49, 95% CI 1.03–2.14; and aHR 1.53, 95% CI 1.05–2.23, respectively), but not thereafter. Of note, 67 (0.74%) TB contacts and 88 (0.24%) matched controls developed active TB, but none of them had subsequent depressive disorder during follow-up periods. Female TB contacts had an increased risk of depression within the first 2 years after exposure. Clinicians should consider conducting depression evaluations in addition to

  6. The effect of baking conditions on the effective contact areas of screen-printed silver layer on silicon substrate

    Energy Technology Data Exchange (ETDEWEB)

    Tietun Sun; Jianmin Miao; Rongming Lin; Yongqing Fu [Nanyang Technological Univ., Micromachines Lab., Singapore (Singapore)

    2005-01-01

    In this paper, Ag-based paste was screen-printed on polished as well as on textured p-type (100) single crystalline silicon wafers. Three types of baking processes were studied: the tube furnace, the belt furnace and the hot plate baking. The effective contact areas of Ag/Si system were measured with a novel method, namely metal insulator semiconductor structure measurement. The results show that after baking on the hot plate at 400 deg C for 5 min, the size and number of pores in the Ag film layer as well as at the interface between silver layer and silicon decreases significantly, the effective contact area also increases about 20%, particularly on the textured silicon substrate. (Author)

  7. The effect of baking conditions on the effective contact areas of screen-printed silver layer on silicon substrate

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Tietun; Miao, Jianmin; Lin, Rongming; Fu, Yongqing [Micromachines Laboratory, School of Mechanical and Production Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)

    2005-01-01

    In this paper, Ag-based paste was screen-printed on the polished as well as on the textured p-type (100) single crystalline silicon wafers. Three types of baking processes were studied: the tube furnace, the belt furnace and the hot plate baking. The effective contact areas of Ag/Si system were measured with a novel method, namely metal insulator semiconductor structure measurement. The results show that after baking on the hot plate at 400{sup o}C for 5min, the size and number of pores in the Ag film layer as well as at the interface between silver layer and silicon decreases significantly, the effective contact area also increases about 20%, particularly on the textured silicon substrate.

  8. Bony contact area and displacement of the temporomandibular joint after high-oblique and bilateral sagittal split osteotomy: a computer-simulated comparison.

    Science.gov (United States)

    Möhlhenrich, Stephan Christian; Kamal, Mohammad; Peters, Florian; Fritz, Ulrike; Hölzle, Frank; Modabber, Ali

    2016-04-01

    The most common way to move the mandible during orthognathic surgery is by bilateral sagittal split osteotomy (BSSO). The high-oblique sagittal split osteotomy (HSSO) is an alternative, although its use is limited by potential complications, mainly to do with the position of the condyle and reduced contact with bone. The aim of this study was to find out the optimal intercondylar distance and area of contact with the surface of the bone for mandibular advancement and setback in BSSO and HSSO. Data from computed tomographic (CT) images from 40 patients were loaded into special planning software, and virtual operations done for mandibular advancement and setback at 3, 5, 8, and 10mm using BSSO and HSSO, which resulted in 640 individual mandibular displacements. The resultant area of bony contact and intercondylar distance were calculated by the software. The mean (SD) areas of contact with the bony surface after 10mm advancement for HSSO and BSSO were 193.94 (63.76) mm(2) and 967.92 (229.21) mm(2), respectively, and after 10mm setback 202.64 (62.30) mm(2) and 1108.86 (247.38) mm(2). The mean corresponding intercondylar distance after maximum advancement were 86.76 (6.40) mm and 86.59 (6.24) mm, and after maximum setback 74.90 (5.73) mm and 73.06 (6.06) mm. There were significant differences between the two for the area of contact with the surface at each displacement distance (parea of bony contact can be expected at any displacement distance for BSSO, so the changes in intercondylar distance should not be considered when deciding which osteotomy to select. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Full area covered 3D profile measurement of special-shaped optics based on a new prototype non-contact profiler.

    Science.gov (United States)

    Du, Hui-Lin; Zhou, Zhao-Zhong; Sun, Ze-Qing; Ju, Bing-Feng; Xu, Shaoning; Sun, Anyu

    2017-06-01

    A new prototype non-contact profiler based on surface tracking has been specially developed. Surface tracking is carried out by a specially designed dual stage probe system with the aid of a four-Degree Of Freedom high-precision motion platform. The dual stage probe system keeps a short-range optical probe constantly tracking the surface by a self-developed voice coil motor servo, by which a wide measuring range of up to 10 mm is realized. The system performance evaluation including resolution, repeatability, and scanning speed proved the good capability of the new prototype non-contact profiler. To realize a full area covered 3D profile measurement of special-shaped optics within one scanning procedure, a signal intensity monitor integrated in the surface tracking controller is specially developed. In the experiment, a snip-single-corner-rectangular-shaped freeform surface was successfully measured over full area by the new non-contact profiler. This work provides an effective solution for 3D profile measurement of special-shaped optical surfaces over full reflecting area. Experimental results demonstrate that the proposed measuring system is of great significance in quality evaluation of optical surfaces.

  10. Footprint Contact Area and Interface Pressure Comparison Between the Knotless and Knot-Tying Transosseous-Equivalent Technique for Rotator Cuff Repair.

    Science.gov (United States)

    Kim, Sung-Jae; Kim, Sung-Hwan; Moon, Hyun-Soo; Chun, Yong-Min

    2016-01-01

    To quantify and compare the footprint contact area and interface pressure on the greater tuberosity between knotless and knot-tying transosseous-equivalent (TOE) repair using pressure-sensitive film. We used 11 pairs of fresh-frozen cadaveric shoulders (22 specimens), in which rotator cuff tears were created before repair. Each pair was randomized to either conventional medial knot-tying TOE repair (group A) or medial knotless TOE repair using the modified Mason-Allen technique (group B). Pressure-sensitive film was used to quantify the pressurized contact area and interface pressure between the greater tuberosity and supraspinatus tendon. The mean pressurized contact area was 33.2 ± 2.5 mm(2) for group A and 28.4 ± 2.4 mm(2) for group B. There was a significant difference between groups (P = .005). Although the overall contact configuration of both groups was similar and showed an M shape, group A showed a greater pressurized configuration around the medial row. The mean interface pressure was 0.20 ± 0.02 MPa for group A and 0.17 ± 0.02 MPa for group B. There was a significant difference between groups (P = .001). Contrary to our hypothesis, in this time-zero study, medial knotless TOE repair using a modified Mason-Allen suture produced a significantly inferior footprint contact area and interface pressure compared with conventional medial knot-tying TOE repair. Even though we found a statistically significant difference between the 2 repair methods, it is still unknown if this statistical difference seen in our study has any clinical and radiologic significance. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Label-free potentiometric biosensor based on solid-contact for determination of total phenols in honey and propolis.

    Science.gov (United States)

    Draghi, Patrícia Ferrante; Fernandes, Julio Cesar Bastos

    2017-03-01

    We developed a label-free potentiometric biosensor using tyrosinase extracted from Musa acuminata and immobilized by covalent bond on a surface of a solid-contact transducer. The transducer was manufactured containing two layers. The first layer contained a blend of poly(vinyl) chloride carboxylated (PVC-COOH), graphite and potassium permanganate. On this layer, we deposited a second layer containing just a mixture of poly(vinyl chloride) carboxylated and graphite. On the last layer of the transducer, we immobilized the tyrosinase enzyme by reaction with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride. The solid-contact potentiometric biosensor presented at low detection limit of 7.3×10 -7 M and a linear range to catechol concentration between 9.3×10 -7 M and 8.3×10 -2 M. This biosensor was applied to determine the amount of total phenols in different samples of honey and propolis. The results agreed with the Folin-Ciocalteu method. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Rough Surface Contact

    Directory of Open Access Journals (Sweden)

    T Nguyen

    2017-06-01

    Full Text Available This paper studies the contact of general rough curved surfaces having nearly identical geometries, assuming the contact at each differential area obeys the model proposed by Greenwood and Williamson. In order to account for the most general gross geometry, principles of differential geometry of surface are applied. This method while requires more rigorous mathematical manipulations, the fact that it preserves the original surface geometries thus makes the modeling procedure much more intuitive. For subsequent use, differential geometry of axis-symmetric surface is considered instead of general surface (although this “general case” can be done as well in Chapter 3.1. The final formulas for contact area, load, and frictional torque are derived in Chapter 3.2.

  13. [Sport injuries in full contact and semi-contact karate].

    Science.gov (United States)

    Greier, K; Riechelmann, H; Ziemska, J

    2014-03-01

    Karate enjoys great popularity both in professional and recreational sports and can be classified into full, half and low contact styles. The aim of this study was the analysis of sports injuries in Kyokushinkai (full contact) and traditional Karate (semi-contact). In a retrospective study design, 215 active amateur karateka (114 full contact, 101 semi-contact) were interviewed by means of a standardised questionnaire regarding typical sport injuries during the last 36 months. Injuries were categorised into severity grade I (not requiring medical treatment), grade II (single medical treatment), grade III (several outpatient medical treatments) and grade IV (requiring hospitalisation). In total, 217 injuries were reported in detail. 125 injuries (58%) occurred in full contact and 92 (42%) in semi-contact karate. The time related injury rate of full contact karateka was 1.9/1000 h compared to 1.3/1000 h of semi-contact karateka (p injuries were musculoskeletal contusions (33% full contact, 20% semi-contact), followed by articular sprains with 19% and 16%. The lower extremity was affected twice as often in full contact (40%) as in semi-contact (20%) karate. Training injuries were reported by 80% of the full contact and 77% of the semi-contact karateka. Most injuries, both in training and competition, occurred in kumite. 75% of the reported injuries of full contact and 70% of semi-contact karateka were classified as low grade (I or II). The high rate of injuries during training and kumite (sparring) points to specific prevention goals. The emphasis should be put on proprioceptive training and consistent warm-up. In the actual competition the referees play a vital role regarding prevention. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Contact-free sheet resistance determination of large area graphene layers by an open dielectric loaded microwave cavity

    International Nuclear Information System (INIS)

    Shaforost, O.; Wang, K.; Adabi, M.; Guo, Z.; Hanham, S.; Klein, N.; Goniszewski, S.; Gallop, J.; Hao, L.

    2015-01-01

    A method for contact-free determination of the sheet resistance of large-area and arbitrary shaped wafers or sheets coated with graphene and other (semi) conducting ultrathin layers is described, which is based on an open dielectric loaded microwave cavity. The sample under test is exposed to the evanescent resonant field outside the cavity. A comparison with a closed cavity configuration revealed that radiation losses have no significant influence of the experimental results. Moreover, the microwave sheet resistance results show good agreement with the dc conductivity determined by four-probe van der Pauw measurements on a set of CVD samples transferred on quartz. As an example of a practical application, correlations between the sheet resistance and deposition conditions for CVD graphene transferred on quartz wafers are described. Our method has a high potential as measurement standard for contact-free sheet resistance measurement and mapping of large area graphene samples

  15. Contact with turf algae alters the coral microbiome: contact versus systemic impacts

    Science.gov (United States)

    Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.

    2018-03-01

    Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.

  16. A pairwise residue contact area-based mean force potential for discrimination of native protein structure

    Directory of Open Access Journals (Sweden)

    Pezeshk Hamid

    2010-01-01

    Full Text Available Abstract Background Considering energy function to detect a correct protein fold from incorrect ones is very important for protein structure prediction and protein folding. Knowledge-based mean force potentials are certainly the most popular type of interaction function for protein threading. They are derived from statistical analyses of interacting groups in experimentally determined protein structures. These potentials are developed at the atom or the amino acid level. Based on orientation dependent contact area, a new type of knowledge-based mean force potential has been developed. Results We developed a new approach to calculate a knowledge-based potential of mean-force, using pairwise residue contact area. To test the performance of our approach, we performed it on several decoy sets to measure its ability to discriminate native structure from decoys. This potential has been able to distinguish native structures from the decoys in the most cases. Further, the calculated Z-scores were quite high for all protein datasets. Conclusions This knowledge-based potential of mean force can be used in protein structure prediction, fold recognition, comparative modelling and molecular recognition. The program is available at http://www.bioinf.cs.ipm.ac.ir/softwares/surfield

  17. Tracing contacts of TB patients in Malaysia: costs and practicality.

    Science.gov (United States)

    Atif, Muhammad; Sulaiman, Syed Azhar Syed; Shafie, Asrul Akmal; Ali, Irfhan; Asif, Muhammad

    2012-01-01

    Tuberculin skin testing (TST) and chest X-ray are the conventional methods used for tracing suspected tuberculosis (TB) patients. The purpose of the study was to calculate the cost incurred by Penang General Hospital on performing one contact tracing procedure using an activity based costing approach. Contact tracing records (including the demographic profile of contacts and outcome of the contact tracing procedure) from March 2010 until February 2011 were retrospectively obtained from the TB contact tracing record book. The human resource cost was calculated by multiplying the mean time spent (in minutes) by employees doing a specific activity by their per-minute salaries. The costs of consumables, Purified Protein Derivative vials and clinical equipment were obtained from the procurement section of the Pharmacy and Radiology Departments. The cost of the building was calculated by multiplying the area of space used by the facility with the unit cost of the public building department. Straight-line deprecation with a discount rate of 3% was assumed for the calculation of equivalent annual costs for the building and machines. Out of 1024 contact tracing procedures, TST was positive (≥10 mm) in 38 suspects. However, chemoprophylaxis was started in none. Yield of contact tracing (active tuberculosis) was as low as 0.5%. The total unit cost of chest X-ray and TST was MYR 9.23 (2.90 USD) & MYR 11.80 (USD 3.70), respectively. The total cost incurred on a single contact tracing procedure was MYR 21.03 (USD 6.60). Our findings suggest that the yield of contact tracing was very low which may be attributed to an inappropriate prioritization process. TST may be replaced with more accurate and specific methods (interferon gamma release assay) in highly prioritized contacts; or TST-positive contacts should be administered 6H therapy (provided that the chest radiography excludes TB) in accordance with standard protocols. The unit cost of contact tracing can be significantly

  18. Daily patterns of communication and contact between Italian early adolescents and their friends.

    Science.gov (United States)

    Baiocco, Roberto; Laghi, Fiorenzo; Schneider, Barry H; Dalessio, Maria; Amichai-Hamburger, Yair; Coplan, Robert J; Koszycki, Diana; Flament, Martine

    2011-01-01

    The goal of the present study was to explore patterns of communication between adolescents and their friends across both "online" and "in-person" contexts. The participants were adolescents (n = 727) aged 11-16 years attending middle schools in urban and rural areas of Italy. Participants completed daily logs of their in-person and online contacts with friends for 20 consecutive school days. Girls reported more total contacts with their friends than did boys as well as friendships that were closer and more intimate. However, boys indicated more contact than girls via electronic communication and online. Contacts with peers in general were less frequent among the older participants, perhaps because of increasing academic demands. Participants who complemented in-person contact with friends with electronic contact were less lonely than their counterparts who were less versatile in accessing different modalities of making contact with friends.

  19. Service contacts prior to death in people dying by suicide in the Scottish Highlands.

    Science.gov (United States)

    Stark, Cameron R; Vaughan, Susan; Huc, Sara; O'Neill, Noelle

    2012-01-01

    Many people who die by suicide have been in contact with health services prior to their death. This study examined service contacts in people in urban and rural areas of the Scottish Highlands. Highland residents dying by suicide or undetermined intent in 2001-2004 were identified using routine death records. Health service databases were searched to identify general hospital, mental health and general practice notes. 177 residents died in the time period (136 males). At least one type of record was identified on 175 people, including general practice records (167 people, 94.4%), psychiatric hospital records (n=87, 49.2%) and general hospital records (n=142, 80.2%). Of these, 52.5% had been in contact with at least one health service in the month before their death, including 18.6% with mental health services, and 46.4% with general practice. In total, 68.9% had a previous diagnosis of mental illness, 52.5% of substance misuse problems, and 40.1% of self-harm. The commonest mental illness diagnosis was depression (n=97, 54.8%). There was no difference in rates of GP contact in rural and urban areas. Of those dying in urban areas, 32% had been in contact with mental health services in the previous month, compared with 21% in Accessible Rural/Accessible Small Towns, and 11% in Remote Rural/Remote Small Towns (prural areas were less likely to have had contact with mental health services in the year before their death (prural than urban areas, and this finding increased with greater rurality.

  20. Effect of meniscus replacement fixation technique on restoration of knee contact mechanics and stability.

    Science.gov (United States)

    D'Lima, D D; Chen, P C; Kessler, O; Hoenecke, H R; Colwell, C W

    2011-06-01

    The menisci are important biomechanical components of the knee. We developed and validated a finite element model of meniscal replacement to assess the effect of surgical fixation technique on contact behavior and knee stability. The geometry of femoral and tibial articular cartilage and menisci was segmented from magnetic resonance images of a normal cadaver knee using MIMICS (Materialise, Leuven, Belgium). A finite element mesh was generated using HyperWorks (Altair Inc, Santa Ana, CA). A finite element solver (Abaqus v6.9, Simulia, Providence, RI) was used to compute contact area and stresses under axial loading and to assess stability (reaction force generated during anteroposterior translation of the femur). The natural and surgical attachments of the meniscal horns and peripheral rim were simulated using springs. After total meniscectomy, femoral contact area decreased by 26% with a concomitant increase in average contact stresses (36%) and peak contact stresses (33%). Replacing the meniscus without suturing the horns did little to restore femoral contact area. Suturing the horns increased contact area and reduced peak contact stresses. Increasing suture stiffness correlated with increased meniscal contact stresses as a greater proportion of tibiofemoral load was transferred to the meniscus. A small incremental benefit was seen of simulated bone plug fixation over the suture construct with the highest stiffness (50 N/mm). Suturing the rim did little to change contact conditions. The nominal anteroposterior stiffness reduced by 3.1 N/mm after meniscectomy. In contrast to contact area and stress, stiffness of the horn fixation sutures had a smaller effect on anteroposterior stability. On the other hand suturing the rim of the meniscus affected anteroposterior stability to a much larger degree. This model emphasizes the importance of the meniscus in knee biomechanics. Appropriate meniscal replacement fixation techniques are likely to be critical to the clinical

  1. Contact Tracing during an Outbreak of Ebola Virus Disease in the Western Area Districts of Sierra Leone: Lessons for Future Ebola Outbreak Response.

    Science.gov (United States)

    Olu, Olushayo Oluseun; Lamunu, Margaret; Nanyunja, Miriam; Dafae, Foday; Samba, Thomas; Sempiira, Noah; Kuti-George, Fredson; Abebe, Fikru Zeleke; Sensasi, Benjamin; Chimbaru, Alexander; Ganda, Louisa; Gausi, Khoti; Gilroy, Sonia; Mugume, James

    2016-01-01

    Contact tracing is a critical strategy required for timely prevention and control of Ebola virus disease (EVD) outbreaks. Available evidence suggests that poor contact tracing was a driver of the EVD outbreak in West Africa, including Sierra Leone. In this article, we answered the question as to whether EVD contact tracing, as practiced in Western Area (WA) districts of Sierra Leone from 2014 to 2015, was effective. The goal is to describe contact tracing and identify obstacles to its effective implementation. Mixed methods comprising secondary data analysis of the EVD case and contact tracing data sets collected from WA during the period from 2014 to 2015, key informant interviews of contact tracers and their supervisors, and a review of available reports on contact tracing were implemented to obtain data for this study. During the study period, 3,838 confirmed cases and 32,706 contacts were listed in the viral hemorrhagic fever and contact databases for the district (mean 8.5 contacts per case). Only 22.1% (852) of the confirmed cases in the study area were listed as contacts at the onset of their illness, which indicates incomplete identification and tracing of contacts. Challenges associated with effective contact tracing included lack of community trust, concealing of exposure information, political interference with recruitment of tracers, inadequate training of contact tracers, and incomplete EVD case and contact database. While the tracers noted the usefulness of community quarantine in facilitating their work, they also reported delayed or irregular supply of basic needs, such as food and water, which created resistance from the communities. Multiple gaps in contact tracing attributed to a variety of factors associated with implementers, and communities were identified as obstacles that impeded timely control of the EVD outbreak in the WA of Sierra Leone. In future outbreaks, early community engagement and participation in contact tracing, establishment of

  2. Evaluation of anti-tuberculosis antibodies in healthy contact and non-contacts persons

    International Nuclear Information System (INIS)

    Aziz, N; Bukhari, M.H; Muneer, M; Tayyab, M; Chaudhry, N.A.

    2006-01-01

    This study was conducted to see the presence of the antimycobacterial antibodies in healthy household contacts of tuberculosis patients and healthy normal subjects who have never been in contact with tuberculosis patients. A total of 200 subjects, 120 with history of household contact and 80 without such history were included in the study. Routine Haematological investigations were performed and all the sera of 200 subjects were tested who 19M, 19G and IgA anti tuberculosis antibodies using ELISA technique. There was no difference in the average age of the household contacts and non-contacts. The complaints of pyrexia, night sweats and loss of weight was more in house hold contacts as compared to non-contacts. The awareness about BCG vaccination was equal among the household contacts and non-contacts. The combined serological positivity of the household contacts was 65.8% and the combined serological positivity for non-contacts was 34.1%. There was no statistically significant difference in the presence of 19M among household contacts as compared to non-contacts. However both IgG and 19A were present in significantly higher number of household contacts as compared to non contacts. This study concludes that the persons living in the house with a patient suffering from active pulmonary tuberculosis (household contact) have more chances of being infected with Mycobacterium tuberculosis as compared to the healthy non-contacts. (author)

  3. Elevation of surficial sediment/basalt contact in the Subsurface Disposal Area, Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Hubbell, J.M.

    1993-01-01

    The elevation of the surficial sediment/basalt contact at the Subsurface Disposal Area (SDA), within the Radioactive Waste Management Complex (RWMC) is presented to provide a data base for future remedial actions at this site. About 1,300 elevation data from published and unpublished reports, maps, and surveyors notes were compiled to generate maps and cross-sections of the surficial sediment/basalt contact. In general, an east to west trending depression exists in the south central portion of the SDA with basalt closer to land surface on the northern and southern boundaries of the SDA. The lowest elevation of the surficial sediment/basalt contact is 4,979 ft and the greatest is land surface at 5,012 ft. The median elevation of the sediment/basalt interface is 4,994 ft. The median depth to basalt in the SDA is 16 ft if land surface elevation is assumed to be 5,010 ft. The depth from land surface to the sediment/basalt interface ranges from 24 ft in the southeast corner of the SDA to less than 3 ft at the north-central boundary of the SDA

  4. Improvements To Micro Contact Performance And Reliability

    Science.gov (United States)

    2016-12-22

    layers approximately 0.2mm thick. The extruder is controlled in both the x and y directions by servo motors while the plate height is controlled with a...and contact area as the contacts pressed together and shared more surface area as the contacts elastically or plastically pressed together[164]. Figure...CrossRef 33. M. Braunovic, N. K. Myshkin, and V. V. Konchits, Electrical contacts: funda- mentals, applications and technology. CRC press , 2010, vol

  5. Current contact device for a superconducting magnet coil

    International Nuclear Information System (INIS)

    Hieronymus, H.

    1987-01-01

    The invention concerns a current supply device for a superconducting magnet coil to be shortcircuited, with a separating device per coil end, which contains a fixed cooled contact and a moving contact connected to a power supply device and a mechanical actuating device for closing and opening the contacts. When closing the heated contact on to the cooled contact, relatively large quantities of heat can be transferred to the cooled contact and therefore to the connected superconducting coil end and can cause normal conduction there. The invention therefore provides that the mass ratio of the cooled contact to the moving contact is at least 5:1, preferably at least 10:1, and that the cooled contact part is provided, at the end away from the contact area, with means for increasing the area, for example cooling fins and is connected to the coil end has a thermal resistance between the contact area and the coil end of at least 0.2 k/W, preferably at least 0.5 k/W per 1000 A of current to be transmitted. (orig.) [de

  6. Effect of occlusal contact stability on the jaw closing point during tapping movements.

    Science.gov (United States)

    Nishigawa, Keisuke; Suzuki, Yoshitake; Ishikawa, Teruaki; Bando, Eiichi

    2012-04-01

    We studied the relationship between tapping point reproducibility and stability of occlusal contacts at maximum intercuspation. Tapping movements of 12 adult volunteers who had dentition with natural teeth were recorded, and distances between the tapping point (TP) and the intercuspal position (ICP) at the incisal point were calculated. Occlusal contacts at the ICP of individual subjects were also evaluated with black-colored silicone impression material. The correlation between TP-ICP distance and occlusal contact stability was studied. TP-ICP distance exhibited negative correlations with the total number of teeth showing occlusal contact at the ICP. Standard deviations of TP-ICP distance also negatively correlated with the extension of occlusal contact area over dentition. This finding indicates that occlusal contacts at the ICP affect the kinematic behavior of tapping movements. The results of this study also suggest that jaw movement data may provide useful clinical information for the evaluation of occlusal contact at ICP. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. Effect of Length, Diameter, Chirality, Deformation, and Strain on Contact Thermal Conductance between Single Wall Carbon Nanotubes

    Science.gov (United States)

    Varshney, Vikas; Lee, Jonghoon; Brown, Joshua S.; Farmer, Barry L.; Voevodin, Andrey A.; Roy, Ajit K.

    2018-04-01

    Thermal energy transfer across physically interacting single-wall carbon nanotube (SWCNT) interconnects has been investigated using non-equilibrium molecular dynamics simulations. The role of various geometrical and structural (length, diameter, chirality) as well as external (deformation and strain) carbon nanotube (CNT) parameters has been explored to estimate total as well as area-normalized thermal conductance across cross-contact interconnects. It is shown that the CNT aspect ratio and degree of lateral as well as tensile deformation play a significant role in determining the extent of thermal energy exchange across CNT contacts, while CNT chirality has a negligible influence on thermal transport. Depending on the CNT diameter, aspect ratio, and degree of deformation at the contact interface, the thermal conductance values can vary significantly –by more than an order of magnitude for total conductance and a factor of 3 to 4 for area-normalized conductance. The observed trends are discussed from the perspective of modulation in number of low frequency out-of-plane (transverse, flexural, and radial) phonons that transmit thermal energy across the contact and govern the conductance across the interface. The established general dependencies for phonon governed thermal transport at CNT contacts are anticipated to help design and performance prediction of CNT-based flexible nanoelectronic devices, where CNT-CNT contact deformation and strain are routinely encountered during device operations.

  8. Contact mechanics of reverse engineered distal humeral hemiarthroplasty implants.

    Science.gov (United States)

    Willing, Ryan; King, Graham J W; Johnson, James A

    2015-11-26

    Erosion of articular cartilage is a concern following distal humeral hemiarthroplasty, because native cartilage surfaces are placed in contact with stiff metallic implant components, which causes decreases in contact area and increases in contact stresses. Recently, reverse engineered implants have been proposed which are intended to promote more natural contact mechanics by reproducing the native bone or cartilage shape. In this study, finite element modeling is used in order to calculate changes in cartilage contact areas and stresses following distal humeral hemiarthroplasty with commercially available and reverse engineered implant designs. At the ulna, decreases in contact area were -34±3% (p=0.002), -27±1% (pengineered and cartilage reverse engineered designs, respectively. Peak contact stresses increased by 461±57% (p=0.008), 387±127% (p=0.229) and 165±16% (p=0.003). At the radius, decreases in contact area were -21±3% (p=0.013), -13±2% (p0.999), 241±32% (p=0.010) and 61±10% (p=0.021). Between the three different implant designs, the cartilage reverse engineered design yielded the largest contact areas and lowest contact stresses, but was still unable to reproduce the contact mechanics of the native joint. These findings align with a growing body of evidence indicating that although reverse engineered hemiarthroplasty implants can provide small improvements in contact mechanics when compared with commercially available designs, further optimization of shape and material properties is required in order reproduce native joint contact mechanics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Effect of skin hydration on the dynamics of fingertip gripping contact.

    Science.gov (United States)

    André, T; Lévesque, V; Hayward, V; Lefèvre, P; Thonnard, J-L

    2011-11-07

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction.

  10. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  11. Effect of electrode contact area on the information content of the recorded electrogastrograms: An analysis based on Rényi entropy and Teager-Kaiser Energy

    Science.gov (United States)

    Alagumariappan, Paramasivam; Krishnamurthy, Kamalanand; Kandiah, Sundravadivelu; Ponnuswamy, Mannar Jawahar

    2017-06-01

    Electrogastrograms (EGG) are electrical signals originating from the digestive system, which are closely correlated with its mechanical activity. Electrogastrography is an efficient non-invasive method for examining the physiological and pathological states of the human digestive system. There are several factors such as fat conductivity, abdominal thickness, change in electrode surface area etc, which affects the quality of the recorded EGG signals. In this work, the effect of variations in the contact area of surface electrodes on the information content of the measured electrogastrograms is analyzed using Rényi entropy and Teager-Kaiser Energy (TKE). Two different circular cutaneous electrodes with approximate contact areas of 201.14 mm2 and 283.64 mm2, have been adopted and EGG signals were acquired using the standard three electrode protocol. Further, the information content of the measured EGG signals were analyzed using the computed values of entropy and energy. Results demonstrate that the information content of the measured EGG signals increases by 6.72% for an increase in the contact area of the surface electrode by 29.09%. Further, it was observed that the average energy increases with increase in the contact surface area. This work appears to be of high clinical significance since the accurate measurement of EGG signals without loss in its information content, is highly useful for the design of diagnostic assistance tools for automated diagnosis and mass screening of digestive disorders.

  12. Non-contact ultrasound techniques

    International Nuclear Information System (INIS)

    Khazali Mohd Zin

    2001-01-01

    Non-contact ultrasound plays significant role in material characterisation and inspection. Unlike conventional ultrasonic techniques, non-contact ultrasonic is mostly applicable to areas where the former has its weaknesses and limitations. It is interesting to note that the non-contact ultrasonic technique has an important significant application in industry. The technique is signified by the fact that the object to be inspected is further away from the ultrasonic source, no couplant is needed and inconsistent pressure between the transducer and the specimen can be eliminated. The paper discusses some of the non-contact ultrasound technique and its applications. (Author)

  13. In vivo cartilage contact deformation in the healthy human tibiofemoral joint.

    Science.gov (United States)

    Bingham, J T; Papannagari, R; Van de Velde, S K; Gross, C; Gill, T J; Felson, D T; Rubash, H E; Li, G

    2008-11-01

    In vivo cartilage contact deformation is instrumental for understanding human joint function and degeneration. This study measured the total deformation of contacting articular cartilage in the human tibiofemoral joint during in vivo weight-bearing flexion. Eleven healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system while the subject performed a weight-bearing single-leg lunge. The tibia, femur and associated articulating cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation from full extension to 120 degrees of flexion. In both compartments, minimum peak compartmental contact deformation occurred at 30 degrees of flexion (24 +/- 6% medial, 17 +/- 7% lateral) and maximum peak compartmental deformation occurred at 120 degrees of flexion (30 +/- 13% medial, 30 +/- 10% lateral) during the weight-bearing flexion from full extension to 120 degrees. Average medial contact areas and peak contact deformations were significantly greater than lateral compartment values (P In addition, cartilage thickness in regions of contact was on average 1.4- and 1.1-times thicker than the average thickness of the tibial and femoral cartilage surfaces, respectively (P line knowledge for investigating the effects of various knee injuries on joint contact biomechanics and the aetiology of cartilage degeneration.

  14. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Estimating the total leaf area of the green dwarf coconut tree (Cocos nucifera L.

    Directory of Open Access Journals (Sweden)

    Sousa Elias Fernandes de

    2005-01-01

    Full Text Available Leaf area has significant effect on tree transpiration, and its measurement is important to many study areas. This work aimed at developing a non-destructive, practical, and empirical method to estimate the total leaf area of green dwarf coconut palms (Cocos nucifera L. in plantations located at the northern region of Rio de Janeiro state, Brazil. A mathematical model was developed to estimate total leaf area values (TLA as function of the average lengths of the last three leaf raquis (LR3, and of the number of leaves in the canopy (NL. The model has satisfactory degree of accuracy for agricultural engineering purposes.

  16. Experimental Investigation of Coal Dust Wettability Based on Surface Contact Angle

    Directory of Open Access Journals (Sweden)

    Gang Zhou

    2016-01-01

    Full Text Available Wettability is one of the key chemical properties of coal dust, which is very important to dedusting. In this paper, the theory of liquid wetting solid was presented firstly; then, taking the gas coal of Xinglongzhuang coal mine in China as an example, by determination of critical surface tension of coal piece, it can be concluded that only when the surface tension of surfactant solution is less than 45 mN/m can the coal sample be fully wetted. Due to the effect of particle dispersity, compared with the contact angle of milled coal particle, not all the contact angles of screened coal powder with different sizes have a tendency to increase. Furthermore, by the experiments of coal samples’ specific surface areas and porosities, it can be achieved that the volume of single-point total pore decreases with the gradual decreasing of coal’s porosity, while the ultramicropores’ dispersities and multipoint BET specific surface areas increase. Besides, by a series of contact angle experiments with different surfactants, it can be found that with the increasing of porosity and the decreasing of volume percentage of ultramicropore, the contact angle tends to reduce gradually and the coal dust is much easier to get wetted.

  17. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  18. Direct Laser Interference Patterning: Tailoring of Contact Area for Frictional and Antibacterial Properties

    Directory of Open Access Journals (Sweden)

    Andreas Rosenkranz

    2016-01-01

    Full Text Available Surface functionalization by topographic micro- and nano-structures in order to achieve unique properties, like super-hydrophobicity or ultrahigh light absorption, is a common strategy in nature. In this paper, direct laser interference patterning (DLIP is presented as a promising tool allowing for the generation of such surface patterns on technical surfaces in order to mimic these biological surfaces and effects. Friction optimization and antibacterial effects by DLIP are exemplarily described. Topographic surface patterns on the micro- and nano-scale demonstrated a significant reduction in the coefficient of friction and bacterial adhesion. It was shown that in both cases, the control of the contact area between surfaces or between surface and bacteria is of utmost importance.

  19. Hand hygiene compliance in patients under contact precautions and in the general hospital population.

    Science.gov (United States)

    Almaguer-Leyva, Martín; Mendoza-Flores, Lidia; Medina-Torres, Ana Gabriela; Salinas-Caballero, Ana Gabriela; Vidaña-Amaro, Jose Antonio; Garza-Gonzalez, Elvira; Camacho-Ortiz, Adrián

    2013-11-01

    Hand hygiene (HH) is the single most important intervention for preventing hospital-acquired infections. Contact precautions are a series of actions that infection control units take to reduce the transmission of nosocomial pathogens. We conducted an observational study of HH compliance. Observations were stratified as opportunities in patients under contact precautions and in the general hospital population. Trained infection control personnel performed all direct evaluations. A total of 3,270 opportunities were recorded. HH compliance was statistically higher in patients on contact precautions than in the overall population (70.3% vs 60.4%; P = .0001). Critical care areas had higher HH compliance when patients were isolated by contact precautions. Medical wards were statistically lower in HH when patients were under contact precautions. Respiratory technicians had the highest HH compliance in both overall performance and in patients under contact precautions. Medical students had a lower HH compliance in both evaluations (P Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  20. Mental Health Services Use Predicted by Number of Mental Health Problems and Gender in a Total Population Study

    Directory of Open Access Journals (Sweden)

    Maj-Britt Posserud

    2013-01-01

    Full Text Available We examined the relationship between service use and the number of problem areas as reported by parents and teachers on questionnaires among children aged 7–9 years old in the Bergen Child Study, a total population study including more than 9000 children. A problem area was counted as present if the child scored above the 95th percentile on parent and/or teacher questionnaire. A total number of 13 problem areas were included. Odd ratios (ORs for contact with child and adolescent mental health services (CAMH, school psychology services (SPS, health visiting nurse/physician, and school support were calculated with gender as covariate. The number of symptom areas was highly predictive of service use, showing a dose-response relationship for all services. Children scoring on ≥4 problem areas had a more than hundredfold risk of being in contact with CAMH services compared to children without problems. The mean number of problem areas for children in CAMH and SPS was 6.1 and 4.4 respectively, strongly supporting the ESSENCE model predicting multisymptomatology in children in specialized services. Even after controlling for number of problem areas, boys were twice as likely as girls to be in contact with CAMH, replicating previous findings of female gender being a strong barrier to mental health services.

  1. 77 FR 59629 - Statutorily Mandated Designation of Difficult Development Areas for 2013

    Science.gov (United States)

    2012-09-28

    ... ranking ratio, as described above, was identical (to four decimal places) to the last area selected, and... questions on how areas are designated and on geographic definitions, contact Michael K. Hollar, Senior... year. 2010 Census, 2000 Census, and Metropolitan Area Definitions Data from the 2010 Census on total...

  2. Definition and detection of contact in atomistic simulations

    NARCIS (Netherlands)

    Solhjoo, Soheil; Vakis, Antonis I.

    In atomistic simulations, contact depends on the accurate detection of contacting atoms as well as their contact area. While it is common to define contact between atoms based on the so-called ‘contact distance’ where the interatomic potential energy reaches its minimum, this discounts, for example,

  3. Definition and detection of contact in atomistic simulations

    NARCIS (Netherlands)

    Solhjoo, Soheil; Vakis, Antonis I.

    2015-01-01

    In atomistic simulations, contact depends on the accurate detection of contacting atoms as well as their contact area. While it is common to define contact between atoms based on the so-called ‘contact distance’ where the interatomic potential energy reaches its minimum, this discounts, for example,

  4. Tunnel oxide passivated rear contact for large area n-type front junction silicon solar cells providing excellent carrier selectivity

    Directory of Open Access Journals (Sweden)

    Yuguo Tao

    2016-01-01

    Full Text Available Carrier-selective contact with low minority carrier recombination and efficient majority carrier transport is mandatory to eliminate metal-induced recombination for higher energy conversion efficiency for silicon (Si solar cells. In the present study, the carrier-selective contact consists of an ultra-thin tunnel oxide and a phosphorus-doped polycrystalline Si (poly-Si thin film formed by plasma enhanced chemical vapor deposition (PECVD and subsequent thermal crystallization. It is shown that the poly-Si film properties (doping level, crystallization and dopant activation anneal temperature are crucial for achieving excellent contact passivation quality. It is also demonstrated quantitatively that the tunnel oxide plays a critical role in this tunnel oxide passivated contact (TOPCON scheme to realize desired carrier selectivity. Presence of tunnel oxide increases the implied Voc (iVoc by ~ 125 mV. The iVoc value as high as 728 mV is achieved on symmetric structure with TOPCON on both sides. Large area (239 cm2 n-type Czochralski (Cz Si solar cells are fabricated with homogeneous implanted boron emitter and screen-printed contact on the front and TOPCON on the back, achieving 21.2% cell efficiency. Detailed analysis shows that the performance of these cells is mainly limited by boron emitter recombination on the front side.

  5. Potential Bone to Implant Contact Area of Short Versus Standard Implants: An In Vitro Micro-Computed Tomography Analysis.

    Science.gov (United States)

    Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo

    2016-02-01

    To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.

  6. "Hot cores" in proteins: Comparative analysis of the apolar contact area in structures from hyper/thermophilic and mesophilic organisms

    Directory of Open Access Journals (Sweden)

    Bossa Francesco

    2008-02-01

    Full Text Available Abstract Background A wide variety of stabilizing factors have been invoked so far to elucidate the structural basis of protein thermostability. These include, amongst the others, a higher number of ion-pairs interactions and hydrogen bonds, together with a better packing of hydrophobic residues. It has been frequently observed that packing of hydrophobic side chains is improved in hyperthermophilic proteins, when compared to their mesophilic counterparts. In this work, protein crystal structures from hyper/thermophilic organisms and their mesophilic homologs have been compared, in order to quantify the difference of apolar contact area and to assess the role played by the hydrophobic contacts in the stabilization of the protein core, at high temperatures. Results The construction of two datasets was carried out so as to satisfy several restrictive criteria, such as minimum redundancy, resolution and R-value thresholds and lack of any structural defect in the collected structures. This approach allowed to quantify with relatively high precision the apolar contact area between interacting residues, reducing the uncertainty due to the position of atoms in the crystal structures, the redundancy of data and the size of the dataset. To identify the common core regions of these proteins, the study was focused on segments that conserve a similar main chain conformation in the structures analyzed, excluding the intervening regions whose structure differs markedly. The results indicated that hyperthermophilic proteins underwent a significant increase of the hydrophobic contact area contributed by those residues composing the alpha-helices of the structurally conserved regions. Conclusion This study indicates the decreased flexibility of alpha-helices in proteins core as a major factor contributing to the enhanced termostability of a number of hyperthermophilic proteins. This effect, in turn, may be due to an increased number of buried methyl groups in

  7. CAB-Align: A Flexible Protein Structure Alignment Method Based on the Residue-Residue Contact Area.

    Directory of Open Access Journals (Sweden)

    Genki Terashi

    Full Text Available Proteins are flexible, and this flexibility has an essential functional role. Flexibility can be observed in loop regions, rearrangements between secondary structure elements, and conformational changes between entire domains. However, most protein structure alignment methods treat protein structures as rigid bodies. Thus, these methods fail to identify the equivalences of residue pairs in regions with flexibility. In this study, we considered that the evolutionary relationship between proteins corresponds directly to the residue-residue physical contacts rather than the three-dimensional (3D coordinates of proteins. Thus, we developed a new protein structure alignment method, contact area-based alignment (CAB-align, which uses the residue-residue contact area to identify regions of similarity. The main purpose of CAB-align is to identify homologous relationships at the residue level between related protein structures. The CAB-align procedure comprises two main steps: First, a rigid-body alignment method based on local and global 3D structure superposition is employed to generate a sufficient number of initial alignments. Then, iterative dynamic programming is executed to find the optimal alignment. We evaluated the performance and advantages of CAB-align based on four main points: (1 agreement with the gold standard alignment, (2 alignment quality based on an evolutionary relationship without 3D coordinate superposition, (3 consistency of the multiple alignments, and (4 classification agreement with the gold standard classification. Comparisons of CAB-align with other state-of-the-art protein structure alignment methods (TM-align, FATCAT, and DaliLite using our benchmark dataset showed that CAB-align performed robustly in obtaining high-quality alignments and generating consistent multiple alignments with high coverage and accuracy rates, and it performed extremely well when discriminating between homologous and nonhomologous pairs of proteins

  8. CAB-Align: A Flexible Protein Structure Alignment Method Based on the Residue-Residue Contact Area.

    Science.gov (United States)

    Terashi, Genki; Takeda-Shitaka, Mayuko

    2015-01-01

    Proteins are flexible, and this flexibility has an essential functional role. Flexibility can be observed in loop regions, rearrangements between secondary structure elements, and conformational changes between entire domains. However, most protein structure alignment methods treat protein structures as rigid bodies. Thus, these methods fail to identify the equivalences of residue pairs in regions with flexibility. In this study, we considered that the evolutionary relationship between proteins corresponds directly to the residue-residue physical contacts rather than the three-dimensional (3D) coordinates of proteins. Thus, we developed a new protein structure alignment method, contact area-based alignment (CAB-align), which uses the residue-residue contact area to identify regions of similarity. The main purpose of CAB-align is to identify homologous relationships at the residue level between related protein structures. The CAB-align procedure comprises two main steps: First, a rigid-body alignment method based on local and global 3D structure superposition is employed to generate a sufficient number of initial alignments. Then, iterative dynamic programming is executed to find the optimal alignment. We evaluated the performance and advantages of CAB-align based on four main points: (1) agreement with the gold standard alignment, (2) alignment quality based on an evolutionary relationship without 3D coordinate superposition, (3) consistency of the multiple alignments, and (4) classification agreement with the gold standard classification. Comparisons of CAB-align with other state-of-the-art protein structure alignment methods (TM-align, FATCAT, and DaliLite) using our benchmark dataset showed that CAB-align performed robustly in obtaining high-quality alignments and generating consistent multiple alignments with high coverage and accuracy rates, and it performed extremely well when discriminating between homologous and nonhomologous pairs of proteins in both

  9. The contact mechanics and occurrence of edge loading in modular metal-on-polyethylene total hip replacement during daily activities.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Jin, Zhongmin; Fisher, John

    2016-06-01

    The occurrence of edge loading in hip joint replacement has been associated with many factors such as prosthetic design, component malposition and activities of daily living. The present study aimed to quantify the occurrence of edge loading/contact at the articulating surface and to evaluate the effect of cup angles and edge loading on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip replacement (THR) during different daily activities. A three-dimensional finite element model was developed based on a modular MoP bearing system. Different cup inclination and anteversion angles were modelled and six daily activities were considered. The results showed that edge loading was predicted during normal walking, ascending and descending stairs activities under steep cup inclination conditions (≥55°) while no edge loading was observed during standing up, sitting down and knee bending activities. The duration of edge loading increased with increased cup inclination angles and was affected by the cup anteversion angles. Edge loading caused elevated contact pressure at the articulating surface and substantially increased equivalent plastic strain of the polyethylene liner. The present study suggested that correct positioning the component to avoid edge loading that may occur during daily activities is important for MoP THR in clinical practice. Copyright © 2016. Published by Elsevier Ltd.

  10. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    Science.gov (United States)

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  11. Effect of weed control treatments on total leaf area of plantation black walnut (Juglans nigra)

    Science.gov (United States)

    Jason Cook; Michael R. Saunders

    2013-01-01

    Determining total tree leaf area is necessary for describing tree carbon balance, growth efficiency, and other measures used in tree-level and stand-level physiological growth models. We examined the effects of vegetation control methods on the total leaf area of sapling-size plantation black walnut trees using allometric approaches. We found significant differences in...

  12. Estimating the Contact Endurance of the AISI 321 Stainless Steel Under Contact Gigacycle Fatigue Tests

    Science.gov (United States)

    Savrai, R. A.; Makarov, A. V.; Osintseva, A. L.; Malygina, I. Yu.

    2018-02-01

    Mechanical testing of the AISI 321 corrosion resistant austenitic steel for contact gigacycle fatigue has been conducted with the application of a new method of contact fatigue testing with ultrasonic frequency of loading according to a pulsing impact "plane-to-plane" contact scheme. It has been found that the contact endurance (the ability to resist the fatigue spalling) of the AISI 321 steel under contact gigacycle fatigue loading is determined by its plasticity margin and the possibility of additional hardening under contact loading. It is demonstrated that the appearance of localized deep and long areas of spalling on a material surface can serve as a qualitative characteristic for the loss of the fatigue strength of the AISI 321 steel under impact contact fatigue loading. The value of surface microhardness measured within contact spots and the maximum depth of contact damages in the peripheral zone of contact spots can serve as quantitative criteria for that purpose.

  13. 78 FR 22501 - Designation of Areas for Air Quality Planning Purposes; State of Nevada; Total Suspended Particulate

    Science.gov (United States)

    2013-04-16

    ... Areas for Air Quality Planning Purposes; State of Nevada; Total Suspended Particulate AGENCY... designations for total suspended particulate within the State of Nevada because the designations are no longer necessary. These designations relate to the attainment or unclassifiable areas for total suspended...

  14. The Study of the Impacts of "Running" on the Contact Area of Soles and Maximal Strength among Elite Middle Distance Runners

    Science.gov (United States)

    Uzun, Ahmet; Aydos, Latif; Kaya, Metin; Yuksel, Mehmet Fatih; Pekel, Haci Ahmet

    2017-01-01

    It is possible that running training for many years in athletics affects athletes' running patterns and sole structure. The main aim of this study is to examine the effect of maximal force applied to the floor area and contact area of the athletes with related to mid-distance training for athletics. 18 male athletes who represent Turkey on the…

  15. Quantitative Study of Nanoscale Contact and Pre-Contact Mechanics Using Force Modulation

    National Research Council Canada - National Science Library

    Syed Asif, S. A; Wahl, K. J; Colton, R. J

    1999-01-01

    .... However cantilever instability, conventional force detection and displacement sensing make contact area measurement difficult, hence the measured mechanical properties are usually only qualitative...

  16. Novel patterning of CdS / CdTe thin film with back contacts for photovoltaic application

    Science.gov (United States)

    Ilango, Murugaiya Sridar; Ramasesha, Sheela K.

    2018-04-01

    The heterostructure of patterned CdS / CdTe thin films with back contact have been devised with electron beam lithography and fabricated using sputter deposition technique. The metallic contacts for n-CdS and p-CdTe are patterned such that both are placed at the bottom of the cell. This avoids losses due to contact shading and increases absorption in the window layer. Patterning of the device surface helps in increasing the junction area which can modulate the absorption of more number of photons due to total internal reflection. Computing the surface area between a planar and a patterned device has revealed 133% increase in the junction area. The physical and optical properties of the sputter-deposited CdS / CdTe layers are also presented. J- V characteristics of the solar cell showed the fill factor to be 25.9%, open circuit voltage to be 17 mV and short-circuit current density to be 113.68 A/m2. The increase in surface area is directly related to the increase in the short circuit current of the photovoltaic cell, which is observed from the results of simulated model in Atlas / Silvaco.

  17. The dynamic contact area of elastomers at different velocities

    NARCIS (Netherlands)

    Khafidh, Muhammad; Rodriguez, N.V.; Masen, Marc Arthur; Schipper, Dirk J.

    2016-01-01

    The friction in tribo-systems that contain viscoelastic materials, such as elastomers, is relevant for a large number of applications. Examples include tyres, hoses, transmission and conveyor belts. To quantify the friction in these applications, one must first understand the contact behaviour of

  18. Post-cam mechanics and tibiofemoral kinematics: a dynamic in vitro analysis of eight posterior-stabilized total knee designs.

    Science.gov (United States)

    Arnout, N; Vanlommel, L; Vanlommel, J; Luyckx, J P; Labey, L; Innocenti, B; Victor, J; Bellemans, J

    2015-11-01

    Posterior cruciate ligament (PCL)-substituting total knee arthroplasty (TKA) designs were introduced to avoid paradoxical roll forward of the femur and to optimize knee kinematics. The aim of this in vitro study was to investigate post-cam function and contact mechanics and relate it to knee kinematics during squatting in eight contemporary posterior-stabilized TKA designs. All prostheses were fixed on custom-designed metal fixtures and mounted in a knee rig and five sequential-loaded squats were performed between 30° and 130° of flexion. Contact pressure and contact area were measured using pressure-sensitive Tekscan sensors on the posterior face of the post. Kinematics was recorded with reflective markers and infrared light-capturing cameras. The post-cam mechanisms analyzed in this study are very variable in terms of design features. This leads to large variations in terms of the flexion angle at which the post and cam engage maximal contact force, contact pressure and contact area. We found that more functional post-cam mechanisms, which engage at lower flexion angle and have a similar behavior as normal PCL function, generally show more normal rollback and tibial rotation at the expense of higher contact forces and pressures. All designs show high contact forces. A positive correlation was found between contact force and initial contact angle. Post-cam contact mechanics and kinematics were documented in a standardized setting. Post-cam contact mechanics are correlated with post-cam function. Outcomes of this study can help to develop more functional designs in future. Nevertheless, a compromise will always be made between functional requirements and risk of failure. We assume that more normal knee kinematics leads to more patient satisfaction because of better mobility. Understanding of the post-cam mechanism, and knowing how this system really works, is maybe the clue in further development of new total knee designs.

  19. Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review.

    Science.gov (United States)

    Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray

    2016-05-01

    Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.

  20. Observation of proportionality between friction and contact area at the nanometer scale

    NARCIS (Netherlands)

    Enachescu, M.; Oetelaar, van den R.J.A.; Carpick, R.W.; Ogletree, D.F.; Flipse, C.F.J.; Salmeron, M.B.

    1999-01-01

    The nanotribological properties of a hydrogen-terminated diamond(111)/tungsten-carbide interface have been studied using ultra-high vacuum atomic force microscopy. Both friction and local contact conductance were measured as a function of applied load. The contact conductance experiments provide a

  1. 78 FR 69113 - Statutorily Mandated Designation of Difficult Development Areas for 2014

    Science.gov (United States)

    2013-11-18

    ... identical (to four decimal places) to the last area selected, and its inclusion resulted in only a minor... designated and on geographic definitions, contact Michael K. Hollar, Senior Economist, Economic Development..., 2000 Census, and Metropolitan Area Definitions Data from the 2010 Census on total population of...

  2. Sliding friction: From microscopic contacts to Amontons’ law

    OpenAIRE

    Weber, B.A.

    2017-01-01

    Most engineers describe sliding friction using the friction coefficient, the ratio of frictional force to normal force. While this proportionality is very simple, its origin is not trivial at all and has been subject of investigation for more than a century. The current consensus is that both frictional and normal force are proportional to the 'real contact area'. Surface roughness prevents surfaces from coming into full contact; the real contact area is simply the fraction of the apparent co...

  3. Contact resistance at ceramic interfaces and its dependence on mechanical load

    DEFF Research Database (Denmark)

    Koch, Søren; Hendriksen, P.V.

    2004-01-01

    Low contact resistance between individual components is important for solid oxide fuel cell stacks if high performance is to be achieved. Several mechanisms may result in high contact resistance, e.g., current constriction due to low area of contact and formation of resistive phases between...... the components. In this study, the importance of current constriction due to limited area of contact at an interface is investigated by comparing the characteristics of contacts between LSM pellets with different surface finish. The load behaviour of the contact resistance has been investigated and a power law...... of the contact resistance was calculated using a simple model describing the variation of the contact area with load based on the measured surface roughness. Good agreement between the calculations and the experimentally observed resistances was found. (C) 2004 Elsevier B.V. All rights reserved....

  4. Contact engineering for nano-scale CMOS

    KAUST Repository

    Hussain, Muhammad Mustafa

    2012-09-10

    High performance computation with longer battery lifetime is an essential component in our today\\'s digital electronics oriented life. To achieve these goals, field effect transistors based complementary metal oxide semiconductor play the key role. One of the critical requirements of transistor structure and fabrication is efficient contact engineering. To catch up with high performance information processing, transistors are going through continuous scaling process. However, it also imposes new challenges to integrate good contact materials in a small area. This can be counterproductive as smaller area results in higher contact resistance thus reduced performance for the transistor itself. At the same time, discovery of new one or two-dimensional materials like nanowire, nanotube, or atomic crystal structure materials, introduces new set of challenges and opportunities. In this paper, we are reviewing them in a synchronized fashion: fundamentals of contact engineering, evolution into non-planar field effect transistors, opportunities and challenges with one and two-dimensional materials and a new opportunity of contact engineering from device architecture perspective. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Total effects of contact and residual exposure of bifenthrin and λ-cyhalothrin on the predatory mite Galendromus occidentalis (Acari: Phytoseiidae).

    Science.gov (United States)

    Hamby, Kelly A; Alifano, Jesse A; Zalom, Frank G

    2013-10-01

    Pyrethroid insecticides are generally regarded as acutely toxic to predatory phytoseiid mites; however, persistence of hull split spray pyrethroid residues on almond trees and their effects on phytoseiids have not been quantified over time. Hull split, the separation of the almond hull along the suture, exposes the new crop nuts to infestation by Amyelois transitella (Walker) larvae, and is the preferred timing for insecticides applied for their control. Galendromus occidentalis (Nesbitt) is the most important phytoseiid biocontrol agent for web-spinning spider mites in California (USA) almond orchards, and the impact of bifenthrin and λ-cyhalothrin pyrethroid residue on their survival, fertility, and fecundity was determined. The total effects of direct contact with esfenvalerate, permethrin, bifenthrin and λ-cyhalothrin were also evaluated for comparison. The total effects (E) of direct contact treatments of the four pyrethroids ranged from 77.8 % for esfenvalerate to 98.8 % for bifenthrin. Both bifenthrin and λ-cyhalothrin twig residue would be considered harmful (IOBC class 4) following field application at hull split timing. Bifenthrin twig residue would be considered slightly harmful (IOBC class 2) for up to 3.5 months and harmless (IOBC class 1) after 6 months. λ-cyhalothrin residue would be considered moderately harmful (IOBC class 3) for up to 3.5 months following application and harmless (IOBC class 1) after 6 months. Bifenthrin and λ-cyhalothrin twig residue on treated trees significantly reduced G. occidentalis female survival for up to 6 months post-treatment, however total effects (E) classify these residues as harmless (IOBC class 1) after 6 months. Harmful effects of direct and residual exposure following application have implications for the use of these pyrethroids in an integrated mite management program for perennial crops.

  6. A close-form solution to predict the total melting time of an ablating slab in contact with a plasma

    International Nuclear Information System (INIS)

    Yeh, F.-B.

    2007-01-01

    An exact melt-through time is derived for a one-dimensional heated slab in contact with a plasma when the melted material is immediately removed. The plasma is composed of a collisionless presheath and sheath on a slab, which partially reflects and secondarily emits ions and electrons. The energy transport from plasma to the surface accounting for the presheath and sheath is determined from the kinetic analysis. This work proposes a semi-analytical model to calculate the total melting time of a slab based on a direct integration of the unsteady heat conduction equation, and provides quantitative results applicable to control the total melting time of the slab. The total melting time as a function of plasma parameters and thermophysical properties of the slab are obtained. The predicted energy transmission factor as a function of dimensionless wall potential agrees well with the experimental data. The effects of reflectivities of the ions and electrons on the wall, electron-to-ion source temperature ratio at the presheath edge, charge number, ion-to-electron mass ratio, ionization energy, plasma flow work-to-heat conduction ratios, Stefan number, melting temperature, Biot number and bias voltage on the total melting time of the slab are quantitatively provided in this work

  7. Laser-fired contact formation on metallized and passivated silicon wafers under short pulse durations

    Science.gov (United States)

    Raghavan, Ashwin S.

    The objective of this work is to develop a comprehensive understanding of the physical processes governing laser-fired contact (LFC) formation under microsecond pulse durations. Primary emphasis is placed on understanding how processing parameters influence contact morphology, passivation layer quality, alloying of Al and Si, and contact resistance. In addition, the research seeks to develop a quantitative method to accurately predict the contact geometry, thermal cycles, heat and mass transfer phenomena, and the influence of contact pitch distance on substrate temperatures in order to improve the physical understanding of the underlying processes. Finally, the work seeks to predict how geometry for LFCs produced with microsecond pulses will influence fabrication and performance factors, such as the rear side contacting scheme, rear surface series resistance and effective rear surface recombination rates. The characterization of LFC cross-sections reveals that the use of microsecond pulse durations results in the formation of three-dimensional hemispherical or half-ellipsoidal contact geometries. The LFC is heavily alloyed with Al and Si and is composed of a two-phase Al-Si microstructure that grows from the Si wafer during resolidification. As a result of forming a large three-dimensional contact geometry, the total contact resistance is governed by the interfacial contact area between the LFC and the wafer rather than the planar contact area at the original Al-Si interface within an opening in the passivation layer. By forming three-dimensional LFCs, the total contact resistance is significantly reduced in comparison to that predicted for planar contacts. In addition, despite the high energy densities associated with microsecond pulse durations, the passivation layer is well preserved outside of the immediate contact region. Therefore, the use of microsecond pulse durations can be used to improve device performance by leading to lower total contact resistances

  8. The effect of facial expressions on respirators contact pressures.

    Science.gov (United States)

    Cai, Mang; Shen, Shengnan; Li, Hui

    2017-08-01

    This study investigated the effect of four typical facial expressions (calmness, happiness, sadness and surprise) on contact characteristics between an N95 filtering facepiece respirator and a headform. The respirator model comprised two layers (an inner layer and an outer layer) and a nose clip. The headform model was comprised of a skin layer, a fatty tissue layer embedded with eight muscles, and a skull layer. Four typical facial expressions were generated by the coordinated contraction of four facial muscles. After that, the distribution of the contact pressure on the headform, as well as the contact area, were calculated. Results demonstrated that the nasal clip could help make the respirator move closer to the nose bridge while causing facial discomfort. Moreover, contact areas varied with different facial expressions, and facial expressions significantly altered contact pressures at different key areas, which may result in leakage.

  9. Spreading depression analysis of contact behaviour of rats.

    Science.gov (United States)

    Tikal, K

    1977-08-01

    Social contact behaviour induced by spreading cortical depression was studied in rats. The controls looked for and remained in contact, whereas between the rats with spreading cortical depression and their other partners there was no contact. This phenomenon is due mainly to the absence of an active urge for contact. The contact behaviour of rats is evidently controlled by the cerebral cortex or by subcortical areas of the brain which are inhibited after the elicitation of spreading depression. The experiments show that the contact behaviour of rats has at least two components - an active urge for contact and passive tolerance of contact.

  10. Ink-Jet Printer Forms Solar-Cell Contacts

    Science.gov (United States)

    Alexander, Paul, Jr.; Vest, R. W.; Binford, Don A.; Tweedell, Eric P.

    1988-01-01

    Contacts formed in controllable patterns with metal-based inks. System forms upper metal contact patterns on silicon photovoltaic cells. Uses metallo-organic ink, decomposes when heated, leaving behind metallic, electrically conductive residue in printed area.

  11. Estimation of Magnetic Basement Depth of Oyo Area from ...

    African Journals Online (AJOL)

    Locations and depths to magnetic contacts were estimated from the total intensity magnetic field using Horizontal gradient magnitude (HGM), Analytic signal amplitude (ASA) and Local wavenumber (LWN). The digitized magnetic intensity data of Oyo area, south western Nigeria was analyzed to estimate depths to magnetic ...

  12. The Risk of Depressive Disorder Among Contacts of Tuberculosis Patients in a TB-endemic Area: A Population-based Cohort Study.

    Science.gov (United States)

    Pan, Sheng-Wei; Yen, Yung-Feng; Feng, Jia-Yih; Su, Vincent Yi-Fong; Kou, Yu Ru; Su, Wei-Juin

    2015-10-01

    Tuberculosis (TB) disease may be transmitted to close contacts of index cases, causing physical illness. No studies have investigated the risk of developing depressive disorder among TB contacts in a TB-endemic area.Adult participants with a new diagnosis of TB contact (ICD-9-CM codes V01.1 plus chest radiographic order) since January 1, 2008, were identified from the National Health Insurance Research Database in Taiwan. A control cohort matched for age (±5 y), sex, enrolled years, and income level was selected. These 2 cohorts were followed until December 31, 2012, and observed for the development of depressive disorder. The Kaplan-Meier method and the log-rank test were used to examine the difference in cumulative incidences of depressive disorder between groups. Cox proportional-hazard models were used to calculate adjusted hazard ratios (aHRs) for depressive disorder.The TB contact cohort consisted of 9046 patients and matched controls of 36,184 ones. The mean age of TB contacts was 44.7 years, and 56.0% of them were women. During a mean follow-up period of 2.5 years, 127 (1.40%) TB contacts and 521 (1.44%) matched controls developed depressive disorder. TB exposure was found to be an independent risk factor of depressive disorder in women (aHR 1.34, 95% confidence interval [CI] 1.07-1.68), but not in men (aHR 0.71, 95% CI 0.48-1.06) after adjusting for age, comorbidities, and income levels. The risk of depression was significantly higher for female TB contacts than for matched controls in the first and second years (aHR 1.49, 95% CI 1.03-2.14; and aHR 1.53, 95% CI 1.05-2.23, respectively), but not thereafter. Of note, 67 (0.74%) TB contacts and 88 (0.24%) matched controls developed active TB, but none of them had subsequent depressive disorder during follow-up periods.Female TB contacts had an increased risk of depression within the first 2 years after exposure. Clinicians should consider conducting depression evaluations in addition to routine TB contact

  13. Contact conductance between graphene and quantum wires

    International Nuclear Information System (INIS)

    Li Haidong; Zheng Yisong

    2009-01-01

    The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads

  14. Mathematical Modeling of Contact Problems of Elasticity Theory with Unilateral Discrete Contact

    Directory of Open Access Journals (Sweden)

    I. V. Stankevich

    2015-01-01

    Full Text Available Development and operation of modern machinery and latest technology require reliable estimates of the strength characteristics of the critical elements of structures and technological equipment under the impact of high-intensity thermomechanical loading, accompanied, as a rule, by complex contact interaction. Mathematical modeling of stress-strain state of such parts and components in the contact area, based on adequate mathematical models, modern numerical methods and efficient algorithms that implement the direct determination of displacement fields, strains and stresses, is the main tool that allows fast acquisition of data required for the calculations of strength and durability. The paper considers an algorithm for constructing the numerical solution of the contact problem of elasticity theory in relation to the body, which has an obvious one-sided discrete contact interaction with an elastic half-space. The proposed algorithm is specially designed to have a correction of the tangential forces at discrete contact points, allowing us to achieve sufficiently accurate implementation of the adopted law of friction. The algorithm is embedded in a general finite element technology, with which the application code is generated. Numerical study of discrete unilateral contact interaction of an elastic plate and a rigid half-space showed a high efficiency of the developed algorithm and the application code that implements it.

  15. Contact and non-contact ultrasonic measurement in the food industry: a review

    International Nuclear Information System (INIS)

    Mohd Khairi, Mohd Taufiq; Ibrahim, Sallehuddin; Md Yunus, Mohd Amri; Faramarzi, Mahdi

    2016-01-01

    The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated. (topical review)

  16. Contact and non-contact ultrasonic measurement in the food industry: a review

    Science.gov (United States)

    Taufiq Mohd Khairi, Mohd; Ibrahim, Sallehuddin; Yunus, Mohd Amri Md; Faramarzi, Mahdi

    2016-01-01

    The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated.

  17. Is there a link between blastomere contact surfaces of day 3 embryos and live birth rate?

    Directory of Open Access Journals (Sweden)

    Paternot Goedele

    2012-09-01

    Full Text Available Abstract Background Cell-cell communication and adhesion are essential for the compaction process of early stage embryos. The aim of this study was to develop a non-invasive objective calculation system of embryo compaction in order to test the hypothesis that embryos with a larger mean contact surface result in a higher live birth rate compared to embryos with a lower mean contact surface. Methods Multilevel images of 474 embryos transferred on day 3 were evaluated by the Cellify software. This software calculates the contact surfaces between the blastomeres. The primary outcome of this study was live birth. An ideal range of contact surface was determined and the positive and negative predictive value, the sensitivity, the specificity and the area under the curve for this new characteristic were calculated. Results In total, 115 (24% transferred embryos resulted in a live birth. Selection of an embryo for transfer on its mean contact surface could predict live birth with a high sensitivity (80% and high negative predicting value (83% but with a low positive predictive value (27%, a low specificity (31% and low area under the ROC curve (0.56. The mean contact surface of embryos cultured in a single medium was significantly higher compared to the mean contact surface of embryos cultured in a sequential medium (p = 0.0003. Conclusions Neither the mean contact surface nor the number of contact surfaces of a day 3 embryo had an additional value in the prediction of live birth. The type of culture medium, however, had an impact on the contact surface of an embryo. Embryos cultured in a single medium had a significant larger contact surface compared to embryos cultured in the sequential medium.

  18. Publication analysis of the contact lens field: what are the current topics of interest?

    Science.gov (United States)

    Cardona, Genís; Sanz, Joan P

    2015-01-01

    To determine the main current research interests of scientists working in the contact lens field. All articles published in the 2011 issues of all journals included in the Journal Citation Reports subject category Ophthalmology were inspected to expose those papers related to the contact lens field. Information regarding source journal was obtained and authorship details were recorded to determine the top most prolific authors, institutions and countries. A comprehensive list of key words was compiled to generate a two-dimensional term map in which the frequency of occurrence of a particular term is defined by label size and the distance between two terms is an indication of the relatedness of these terms, based on their co-occurrences within groups of key words. Clusters of related terms were also identified. Visual examination of all articles uncovered a total of 156 papers, published in 28 different journals. Contact Lens & Anterior Eye, Eye & Contact Lens and Optometry and Vision Science had 27 articles each. The most prolific authors and institutions revealed the predominance of countries with long research tradition in the contact lens field. Ten different word clusters or areas of interest were identified, including both traditional, yet unresolved issues (e.g., comfort or dry eye), and the latest research efforts (e.g., myopia control). These findings, which revealed contact lenses to be a fertile area of research, may be of relevance to new researchers as well as to those interested in exploring the latest research trends in this scientific discipline. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  19. Contact Stress Generation on the UHMWPE Tibial Insert

    Directory of Open Access Journals (Sweden)

    S. Petrović Savić

    2014-12-01

    Full Text Available Total knee replacement (TKR is considered, during last years, as a very successful surgical technique for removing knee joint deformities and eliminating pain caused by cartilage damage. In literature, as primary causes for knee joint endoprothesis damage are cited complex movements which cause occurrences of complex stress conditions, sagital radius conformity, sliding, types of materials etc. Aim of this study is analysis of contact stresses that occur on tibial implant for 15°, 45° and 60° knee flexion and 50 kg, 75 kg, 100 kg and 125 kg weight. Knee joint prosthesis model and finite elements method (FEM analysis are done in software Catia V5. For this analysis we used ultra-high molecular weight polyethylene (UHMWPE for tibial implant material and AISI 316, AISI 317, AISI 321, 17-4PH, CoCrMo, Ti6Al4V and SAE A-286 for femoral component materials. Results show that area of maximal contact stress is identified in medial and lateral part of tibial implant. Von Mises stress values vary regarding of flexion degree and weight, but values are approximate for types of chosen materials. Contact stress location corresponds to damage that occur on tibial implant during exploitation.

  20. Numerical simulations of rough contacts between viscoelastic materials

    Science.gov (United States)

    Spinu, S.; Cerlinca, D.

    2017-08-01

    The durability of the mechanical contact is often plagued by surface-related phenomena like rolling contact fatigue, wear or crack propagation, which are linked to the important gradients of stress arising in the contacting bodies due to interaction at the asperity level. The semi-analytical computational approach adopted in this paper is based on a previously reported algorithm capable of simulating the contact between bodies with arbitrary limiting surfaces and viscoelastic behaviour, which is enhanced and adapted for the contact of real surfaces with microtopography. As steep slopes at the asperity level inevitably lead to localized plastic deformation at the tip of the asperities that are first brought into contact, the viscoelastic behaviour is amended by limiting the maximum value of the pressure on the contact area to that of the material hardness, according to the Tabor equation. In this manner, plasticity is considered in a simplified manner that assures the knowledge of the contact area and of the pressure distribution without estimation of the residual state. The main advantage of this approach is the preservation of the algorithmic complexity, allowing the simulation of very fine meshes capable of capturing particular features of the investigated contacting surface. The newly advanced model is expected to predict the contact specifics of rough surfaces as resulting from various manufacturing processes, thus assisting the design of durable machine elements using elastomers or rubbers.

  1. Device including a contact detector

    DEFF Research Database (Denmark)

    2011-01-01

    arms (12) may extend from the supporting body in co-planar relationship with the first surface. The plurality of cantilever arms (12) may extend substantially parallel to each other and each of the plurality of cantilever arms (12) may include an electrical conductive tip for contacting the area......The present invention relates to a probe for determining an electrical property of an area of a surface of a test sample, the probe is intended to be in a specific orientation relative to the test sample. The probe may comprise a supporting body defining a first surface. A plurality of cantilever...... of the test sample by movement of the probe relative to the surface of the test sample into the specific orientation.; The probe may further comprise a contact detector (14) extending from the supporting body arranged so as to contact the surface of the test sample prior to any one of the plurality...

  2. Disinfection Contact Time study plan (100-N Area tracer protocol). Revision 1

    International Nuclear Information System (INIS)

    Kretzschmar, S.P.; Bedi, G.S.; Martinez, P.; Ervin, K.

    1996-07-01

    Bechtel Hanford, Inc. will prepare an Engineering Tracer Study Protocol for the determination of contact time for the disinfection process at Group A Non-transient Non-community water treatment plant for the 100-N Water Plant at the Hanford Site in Richland, Washington. Included in this report are the results of a study that determine the actual detention time within the plant clearwell, and thus the disinfection contact time at several clearwell effluent flow rates

  3. Head-disk interface nanotribology for Tbit/inch2 recording densities: near-contact and contact recording

    Science.gov (United States)

    Vakis, Antonis I.; Polycarpou, Andreas A.

    2010-06-01

    In the effort to achieve Tbit/inch2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.

  4. Head-disk interface nanotribology for Tbit/inch2 recording densities: near-contact and contact recording

    International Nuclear Information System (INIS)

    Vakis, Antonis I; Polycarpou, Andreas A

    2010-01-01

    In the effort to achieve Tbit/inch 2 recording densities, thermal fly-height control (TFC) nanotechnology was developed to effectively reduce the clearance (which is of the order of a few nanometres) at the head-disk interface (HDI) of hard-disk drives. In this work, we present a model of the HDI that can predict the dynamic flying and nanotribological contacting behaviour, allowing for accurate predictions and characterization of the operating regime as a function of TFC actuation. A geometric model for TFC is presented and an improved definition of contact at the interface is developed in the presence of nanoscale topographical roughness and dynamic microwaviness. A new methodology is proposed for the calculation of the nominal area of contact, which affects both near- and at-contact behaviour, while the stiffening of the air bearing force with TFC actuation is also accounted for. Slider behaviour is analysed by quantifying the approach, jump-to-contact, lubricant and solid contact regimes of operation and identifying the critical and optimum TFC actuations. The feasibility of near-contact, light molecularly thin lubricant contact versus solid contact recording is explored under the effect of the interfacial forces and stresses present at the HDI. The clearance and the state of vibrations are analysed and design guidelines are proposed for improved performance.

  5. Simple processing of back-contacted silicon heterojunction solar cells using selective-area crystalline growth

    KAUST Repository

    Tomasi, Andrea; Paviet-Salomon, Bertrand; Jeangros, Quentin; Haschke, Jan; Christmann, Gabriel; Barraud, Loris; Descoeudres, Antoine; Seif, Johannes Peter; Nicolay, Sylvain; Despeisse, Matthieu; De Wolf, Stefaan; Ballif, Christophe

    2017-01-01

    For crystalline-silicon solar cells, voltages close to the theoretical limit are nowadays readily achievable when using passivating contacts. Conversely, maximal current generation requires the integration of the electron and hole contacts at the back of the solar cell to liberate its front from any shadowing loss. Recently, the world-record efficiency for crystalline-silicon single-junction solar cells was achieved by merging these two approaches in a single device; however, the complexity of fabricating this class of devices raises concerns about their commercial potential. Here we show a contacting method that substantially simplifies the architecture and fabrication of back-contacted silicon solar cells. We exploit the surface-dependent growth of silicon thin films, deposited by plasma processes, to eliminate the patterning of one of the doped carrier-collecting layers. Then, using only one alignment step for electrode definition, we fabricate a proof-of-concept 9-cm2 tunnel-interdigitated back-contact solar cell with a certified conversion efficiency >22.5%.

  6. Simple processing of back-contacted silicon heterojunction solar cells using selective-area crystalline growth

    KAUST Repository

    Tomasi, Andrea

    2017-04-24

    For crystalline-silicon solar cells, voltages close to the theoretical limit are nowadays readily achievable when using passivating contacts. Conversely, maximal current generation requires the integration of the electron and hole contacts at the back of the solar cell to liberate its front from any shadowing loss. Recently, the world-record efficiency for crystalline-silicon single-junction solar cells was achieved by merging these two approaches in a single device; however, the complexity of fabricating this class of devices raises concerns about their commercial potential. Here we show a contacting method that substantially simplifies the architecture and fabrication of back-contacted silicon solar cells. We exploit the surface-dependent growth of silicon thin films, deposited by plasma processes, to eliminate the patterning of one of the doped carrier-collecting layers. Then, using only one alignment step for electrode definition, we fabricate a proof-of-concept 9-cm2 tunnel-interdigitated back-contact solar cell with a certified conversion efficiency >22.5%.

  7. Static or breakloose friction for lubricated contacts: the role of surface roughness and dewetting

    International Nuclear Information System (INIS)

    Lorenz, B; Persson, B N J; Krick, B A; Sawyer, W G; Rodriguez, N; Mangiagalli, P

    2013-01-01

    We present experimental data for the static or breakloose friction for lubricated elastomer contacts, as a function of the time of stationary contact. Due to fluid squeeze-out from the asperity contact regions, the breakloose friction force increases continuously with the time of stationary contact. We consider three different cases: (a) PDMS rubber balls against flat smooth glass surfaces, (b) PDMS cylinder ribs against different substrates (glass, smooth and rough PMMA and an inert polymer) and (c) application to syringes. Due to differences in the surface roughness and contact pressures the three systems exhibit very different time dependences of the breakloose friction. In case (a) for rough surfaces the dry contact area A is a small fraction of the nominal contact area A 0 , and the fluid squeeze-out is fast. In case (b) the dry contact area is close to the nominal contact area, A/A 0 ≈ 1, and fluid squeeze-out is very slow due to percolation of the contact area. In this case, remarkably, different fluids with very different viscosities, ranging from 0.005 Pa s (water–glycerol mixture) to 1.48 Pa s (glycerol), give very similar breakloose friction forces as a function of the time of stationary contact. In case (c) the contact pressure and the surface roughness are larger than in case (b), and the squeeze-out is very slow so that even after a very long time the area of real contact is below the percolation threshold. For all cases (a)–(c), the increase in the breakloose friction is mainly due to the increase in the area of real contact with increasing time, because of the fluid squeeze-out and dewetting. (paper)

  8. Static or breakloose friction for lubricated contacts: the role of surface roughness and dewetting.

    Science.gov (United States)

    Lorenz, B; Krick, B A; Rodriguez, N; Sawyer, W G; Mangiagalli, P; Persson, B N J

    2013-11-06

    We present experimental data for the static or breakloose friction for lubricated elastomer contacts, as a function of the time of stationary contact. Due to fluid squeeze-out from the asperity contact regions, the breakloose friction force increases continuously with the time of stationary contact. We consider three different cases: (a) PDMS rubber balls against flat smooth glass surfaces, (b) PDMS cylinder ribs against different substrates (glass, smooth and rough PMMA and an inert polymer) and (c) application to syringes. Due to differences in the surface roughness and contact pressures the three systems exhibit very different time dependences of the breakloose friction. In case (a) for rough surfaces the dry contact area A is a small fraction of the nominal contact area A0, and the fluid squeeze-out is fast. In case (b) the dry contact area is close to the nominal contact area, A/A0 ≈ 1, and fluid squeeze-out is very slow due to percolation of the contact area. In this case, remarkably, different fluids with very different viscosities, ranging from 0.005 Pa s (water–glycerol mixture) to 1.48 Pa s (glycerol), give very similar breakloose friction forces as a function of the time of stationary contact. In case (c) the contact pressure and the surface roughness are larger than in case (b), and the squeeze-out is very slow so that even after a very long time the area of real contact is below the percolation threshold. For all cases (a)–(c), the increase in the breakloose friction is mainly due to the increase in the area of real contact with increasing time, because of the fluid squeeze-out and dewetting.

  9. The role of the roughness spectral breadth in elastic contact of rough surfaces

    Science.gov (United States)

    Yastrebov, Vladislav A.; Anciaux, Guillaume; Molinari, Jean-François

    2017-10-01

    We study frictionless and non-adhesive contact between elastic half-spaces with self-affine surfaces. Using a recently suggested corrective technique, we ensure an unprecedented accuracy in computation of the true contact area evolution under increasing pressure. This accuracy enables us to draw conclusions on the role of the surface's spectrum breadth (Nayak parameter) in the contact area evolution. We show that for a given normalized pressure, the contact area decreases logarithmically with the Nayak parameter. By linking the Nayak parameter with the Hurst exponent (or fractal dimension), we show the effect of the latter on the true contact area. This effect, undetectable for surfaces with poor spectral content, is quite strong for surfaces with rich spectra. Numerical results are compared with analytical models and other available numerical results. A phenomenological equation for the contact area growth is suggested with coefficients depending on the Nayak parameter. Using this equation, the pressure-dependent friction coefficient is deduced based on the adhesive theory of friction. Some observations on Persson's model of rough contact, whose prediction does not depend on Nayak parameter, are reported. Overall, the paper provides a unifying picture of rough elastic contact and clarifies discrepancies between preceding results.

  10. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  11. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    Science.gov (United States)

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  12. Contact Resistance of Ceramic Interfaces Between Materials Used for Solid Oxide Fuel Cell Applications

    DEFF Research Database (Denmark)

    Koch, Søren

    The contact resistance can be divided into two main contributions. The small area of contact between ceramic components results in resistance due to current constriction. Resistive phases or potential barriers at the interface result in an interface contribution to the contact resistance, which may....... The influence of the mechanical load on the contact resistance was ascribed to an area effect. The contact resistance of the investigated materials was dominated by current constric-tion at high temperatures. The measured contact resistance was comparable to the resis-tance calculated on basis of the contact...... areas found by optical and electron microscopy. At low temperatures, the interface contribution to the contact resistance was dominating. The cobaltite interface could be described by one potential barrier at the contact interface, whereas the manganite interfaces required several consecutive potential...

  13. Dependence of compressive strength of green compacts on pressure, density and contact area of powder particles

    International Nuclear Information System (INIS)

    Salam, A.; Akram, M.; Shahid, K.A.; Javed, M.; Zaidi, S.M.

    1994-08-01

    The relationship between green compressive strength and compacting pressure as well as green density has been investigated for uniaxially pressed aluminium powder compacts in the range 0 - 520 MPa. Two linear relationships occurred between compacting pressure and green compressive strength which corresponded to powder compaction stages II and III respectively, increase in strength being large during stage II and quite small in stage III with increasing pressure. On the basis of both, the experimental results and a previous model on cold compaction of powder particles, relationships between green compressive strength and green density and interparticle contact area of the compacts has been established. (author) 9 figs

  14. The Analysis of Three-Body Contact Temperature under the Different Third Particle Size, Density, and Value of Friction

    Directory of Open Access Journals (Sweden)

    Horng-Wen Wu

    2017-10-01

    Full Text Available Recently, many studies have investigated the friction, wear, and temperature characteristics of the interface between two relative movements. Such analyses often set the coefficient of friction as a fixed value and are analyzed in cases of two-body contact; however, the interface is often a three-body contact and the coefficient of friction varies depending on the operating conditions. This is a significant error in the analysis of contact characteristics, therefore, in this study, the actual interface and the change of the coefficient of friction were analyzed based on three-body micro-contact theory where the contact temperature was also analyzed and the difference between the generally assumed values were compared. The results showed that under three-body contact, the coefficient of total friction increased with an increase in particle size; and at a different particle size and area density of particles, the surface contact temperature increased with the plasticity index and load increases, and the particle contact temperature increased with the increasing particle size. The surface temperature rise was mainly affected by the ratio of the average temperature between surface 1 and surface 2 to the multiplication between the 100th root of the area density of particles and the square root of the equivalent surface roughness (Ts1s2_ave*/ηa0.01σ0.5 and the ratio of the 10th root of the mean particle diameter to the 100th root of the equivalent surface roughness (xa0.1/σ0.001. Particle temperature was mainly affected by the ratio of the 10th root of the mean particle diameter to the 100th root of the equivalent surface roughness (xa0.1/σ0.001 and the area density of particles ηa. Our study indicated that when the contact of surface with surface and the contact of the particles with the surface, the resulting heat balance was assigned to the particles and the surface in a three-body contact situation. Under this contact behavior, it could avoid

  15. Lake Chad Total Surface Water Area as Derived from Land Surface Temperature and Radar Remote Sensing Data

    Directory of Open Access Journals (Sweden)

    Frederick Policelli

    2018-02-01

    Full Text Available Lake Chad, located in the middle of the African Sahel belt, underwent dramatic decreases in the 1970s and 1980s leaving less than ten percent of its 1960s surface water extent as open water. In this paper, we present an extended record (dry seasons 1988–2016 of the total surface water area of the lake (including both open water and flooded vegetation derived using Land Surface Temperature (LST data (dry seasons 2000–2016 from the NASA Terra MODIS sensor and EUMETSAT Meteosat-based LST measurements (dry seasons 1988–2001 from an earlier study. We also examine the total surface water area for Lake Chad using radar data (dry seasons 2015–2016 from the ESA Sentinel-1a mission. For the limited number of radar data sets available to us (18 data sets, we find on average a close match between the estimates from these data and the corresponding estimates from LST, though we find spatial differences in the estimates using the two types of data. We use these spatial differences to adjust the record (dry seasons 2000–2016 from MODIS LST. Then we use the adjusted record to remove the bias of the existing LST record (dry seasons 1988–2001 derived from Meteosat measurements and combine the two records. From this composite, extended record, we plot the total surface water area of the lake for the dry seasons of 1988–1989 through 2016–2017. We find for the dry seasons of 1988–1989 to 2016–2017 that the maximum total surface water area of the lake was approximately 16,800 sq. km (February and May, 2000, the minimum total surface water area of the lake was approximately 6400 sq. km (November, 1990, and the average was approximately 12,700 sq. km. Further, we find the total surface water area of the lake to be highly variable during this period, with an average rate of increase of approximately 143 km2 per year.

  16. Relationship between surface, free tropospheric and total column ozone in 2 contrasting areas in South-Africa

    CSIR Research Space (South Africa)

    Combrink, J

    1995-04-01

    Full Text Available Measurements of surface ozone in two contrasting areas of South Africa are compared with free tropospheric and Total Ozone Mapping Spectrometer (TOMS) total column ozone data. Cape Point is representative of a background monitoring station which...

  17. Nordic project food contact materials

    DEFF Research Database (Denmark)

    Li, Ågot; Tesdal Håland, Julie; Petersen, Jens Højslev

    Denmark, Finland, Faroe Islands, Iceland, Norway and Sweden have in 2013––2015 conducted a Nordic project on food contact materials. Food contact materials are used in all stages of food production and can be a general source of contamination. The food safety authorities in most of the Nordic...... countries have had a limited focus on the FCM area with the exception of Denmark and Finland. The aim of the project was therefore to control establishments producing, importing or using plastic food contact materials as well as to increase the knowledge of the inspectors performing these controls....... The focus of the inspections was to control the declaration of compliance (DoC) for plastic food contact materials. The requirement for a Doc is mandatory in order to ensure that the FCM complies with the legislation. In addition some products were analyzed for phthalates....

  18. Leprosy reactions: the effect of gender and household contacts

    Directory of Open Access Journals (Sweden)

    Giuseppe Mastrangelo

    2011-02-01

    Full Text Available Various host-related factors have been reported as relevant risk factors for leprosy reactions. To support a new hypothesis that an antigenic load in local tissues that is sufficient to trigger the immune response may come from an external supply of Mycobacterium leprae organisms, the prevalence of reactional leprosy was assessed against the number of household contacts. The number of contacts was ascertained at diagnosis in leprosy patients coming from an endemic area of Brazil. The prevalence of reactions (patients with reactions/total patients was fitted by binomial regression and the risk difference (RD was estimated with a semi-robust estimation of variance as a measure of effect. Five regression models were fitted. Model 1 included only the main exposure variable "number of household contacts"; model 2 included all four explanatory variables ("contacts", "fertile age", "number of skin lesions" and "bacillary index" that were found to be associated with the outcome upon univariate analysis; models 3-5 contained various combinations of three predictors. Male and female patients were analyzed separately. In females, household contacts were a significant predictor for leprosy reactions in model 1 [crude RD = 0.06; 95% confidence interval (CI = 0.01; 0.12] and model 5 (RD = 0.05; CI = 0.02; 0.09, which included contacts, bacillary index and skin lesions as predictors. Other models were unsatisfactory because the joint presence of fertile age and bacillary index was a likely source of multicollinearity. No significant results were obtained for males. The likely interpretation of our findings might suggest that in female patients, leprosy reactions may be triggered by an external spreading of M. leprae by healthy carrier family members. The small number of observations is an obvious limitation of our study which requires larger confirmatory studies.

  19. Nature Contacts: Employee Wellness in Healthcare.

    Science.gov (United States)

    Trau, Deborah; Keenan, Kimberly A; Goforth, Meggan; Large, Vernon

    2016-04-01

    This study was designed to ascertain the amount of outdoor, indoor, and indirect nature contact exposures hospital employees have in a workweek. Hospital employees have been found particularly vulnerable to work-related stress. Increasing the nature contact exposure for hospital employees can reduce perceived stress; stress-related health behaviors; and stress-related health outcomes from outdoor, indoor, and indirect exposures to nature. Staff on the fourth floor postsurgical unit of a large hospital (N = 42) were ask to participate in an employee questionnaire "nature contact questionnaire". This 16-item nature environment questionnaire measures the amount and types of nature contact exposures employees have during a workweek. Majority of employees reported few, if any, nature contact exposures, specifically in the area of outdoor nature contacts with limited indoor and indirect contacts. These results indicated that employees on the fourth floor postsurgical floor have limited ability to reduce stress through nature contact exposures which could impact their perceived levels of work stress and stress-related behaviors and health outcomes. Nature contact exposures are both a relatively easy and an inexpensive way to improve employee stress. These findings indicate limitations to employees' exposure to nature contacts. Healthcare environments would benefit from a concerted effort to provide increased outdoor, indoor, and indirect nature contact exposures for employees. © The Author(s) 2015.

  20. Deterministic Model for Rubber-Metal Contact Including the Interaction Between Asperities

    NARCIS (Netherlands)

    Deladi, E.L.; de Rooij, M.B.; Schipper, D.J.

    2005-01-01

    Rubber-metal contact involves relatively large deformations and large real contact areas compared to metal-metal contact. Here, a deterministic model is proposed for the contact between rubber and metal surfaces, which takes into account the interaction between neighboring asperities. In this model,

  1. Surface topography and contact mechanics of dry and wet human skin

    Directory of Open Access Journals (Sweden)

    Alexander E. Kovalev

    2014-08-01

    Full Text Available The surface topography of the human wrist skin is studied by using optical and atomic force microscopy (AFM methods. By using these techniques the surface roughness power spectrum is obtained. The Persson contact mechanics theory is used to calculate the contact area for different magnifications, for the dry and wet skin. The measured friction coefficient between a glass ball and dry and wet skin can be explained assuming that a frictional shear stress σf ≈ 13 MPa and σf ≈ 5 MPa, respectively, act in the area of real contact during sliding. These frictional shear stresses are typical for sliding on surfaces of elastic bodies. The big increase in friction, which has been observed for glass sliding on wet skin as the skin dries up, can be explained as result of the increase in the contact area arising from the attraction of capillary bridges. Finally, we demonstrated that the real contact area can be properly defined only when a combination of both AFM and optical methods is used for power spectrum calculation.

  2. Analysis of Tire Contact Parameters Using Visual Processing

    Directory of Open Access Journals (Sweden)

    Valentin Ivanov

    2010-01-01

    The first part of this paper presents the results of experimental estimation of the contact patch area depending on the normal wheel load and inflation pressure for different car tires. The data were obtained for test bench conditions on the basis of the visual processing of tread footprint. Further, the contact length in the cohesion area during wheel rolling for single points on the tire profile has been chosen as a benchmark criterion. This paper has analyzed the influence of the wheel normal load and tire inflation pressure on the contact length with small rolling velocities. The results of the investigations are given for winter and racing tires with different grades of wear.

  3. Gas-liquid contacting in mixing vessels

    International Nuclear Information System (INIS)

    Mann, R.

    1983-01-01

    This report by Dr. R. Mann of UMIST presents a critical survey of literature on the contacting of gases with liquids in stirred vessels. Research undertaken in the last fifteen years in analysed, and promising areas for future research are identified. The report deals with physical contacting, mass transfer between the gas and liquid phases and the utilisation of the stirred vessel as a gas-liquid reactor. Three sections are given on gas-liquid contacting: physical aspects; interphase mass transfer; and chemical reactions. It also discusses recent new approaches and includes a summary of conclusions, nomenclature and references

  4. Contact Estimation in Robot Interaction

    Directory of Open Access Journals (Sweden)

    Filippo D'Ippolito

    2014-07-01

    Full Text Available In the paper, safety issues are examined in a scenario in which a robot manipulator and a human perform the same task in the same workspace. During the task execution, the human should be able to physically interact with the robot, and in this case an estimation algorithm for both interaction forces and a contact point is proposed in order to guarantee safety conditions. The method, starting from residual joint torque estimation, allows both direct and adaptive computation of the contact point and force, based on a principle of equivalence of the contact forces. At the same time, all the unintended contacts must be avoided, and a suitable post-collision strategy is considered to move the robot away from the collision area or else to reduce impact effects. Proper experimental tests have demonstrated the applicability in practice of both the post-impact strategy and the estimation algorithms; furthermore, experiments demonstrate the different behaviour resulting from the adaptation of the contact point as opposed to direct calculation.

  5. Linear and non-linear simulation of joints contact surface using ...

    African Journals Online (AJOL)

    The joint modelling including non-linear effects needs accurate and precise study of their behaviors. When joints are under the dynamic loading, micro, macro- slip happens in contact surface which is non-linear reason of the joint contact surface. The non-linear effects of joint contact surface on total behavior of structure are ...

  6. Fermilab Education Office - Contacts

    Science.gov (United States)

    Search The Office of Education and Public Outreach: Contacts All telephone numbers require area code Presentations for Presenters 840-3094 Office of Education and Public Outreach Spencer Pasero spasero@fnal.gov Education Office 840-3076 Fermilab Friends for Science Education General Questions Susan Dahl sdahl@fnal.gov

  7. Spatial Relation Between Left Atrial Anatomical Contact Areas and Circular Activation in Persistent Atrial Fibrillation.

    Science.gov (United States)

    Nakahara, Shiro; Yamaguchi, Takanori; Hori, Yuichi; Anjo, Naofumi; Hayashi, Akiko; Kobayashi, Sayuki; Komatsu, Takaaki; Sakai, Yoshihiko; Fukui, Akira; Tsuchiya, Takeshi; Taguchi, Isao

    2016-05-01

    Atrial low-voltage zones (LVZs) may be related to maintenance of atrial fibrillation (AF). The influence of left atrial (LA) contact areas (CoAs) on reentrant or rotor-like sources maintaining AF has not been investigated. Forty patients with persistent AF (PsAF) were analyzed. Three representative CoA regions in the LA (ascending aorta: anterior wall; descending aorta: left inferior pulmonary vein; and vertebrae: posterior wall) were visualized by enhanced CT. Using circular catheters, the LVZs (80% of the mean AF cycle length. A pivot was defined as the core of the localized circular activation. Anterior (39/40 patients, 98%), left pulmonary vein antrum (27/40, 68%), and posterior (19/40, 48%) CoAs were identified, and 80% (68/85) of those sites were overlapped by or close (<3 mm) to LVZs. Thirty-six (90%) patients demonstrated circular activation (3.1±1.7 sites/patients) along with significantly higher organized dominant frequencies (6.3 ± 0.5 Hz, regularity-index: 0.26 [0.23-0.41]) within the LA, and the average electrogram amplitude of those pivots was 0.30 mV (0.18-0.52). Of those sites, 55% (66/120) were located at or close to CoA regions. Catheter ablation including of LVZs neighboring CoAs terminated AF in 9 (23%) patients. External anatomical structures contacting the LA may be related to unique conduction properties in diseased myocardium necessary for PsAF maintenance. © 2016 Wiley Periodicals, Inc.

  8. A new theory for the static contact between rough, unmated surfaces in non-elastically deforming rock and its implications for rock friction

    Science.gov (United States)

    Stesky, R. M.; Hannan, S. S.

    The closure behavior of fractures in marble and alabaster is markedly different from that in quartzite. The aperture decreases considerably more under normal stress and remains permanently reduced, for the same ratio of normal stress to unconfined compressive strength. Also, a larger permanent relative contact area develops between the surfaces of marble and alabaster than it does between surfaces of quartzite. The permanent contact area increases at an increasing rate with normal stress in marble and alabaster, unlike the nearly linear increase in quartzite. The failure of surface asperities of calcite and gypsum during closure accounts for these differences. We modeled this process by considering the surfaces to consist of paraboloids lying on a flat plane and having a range of initial heights. Closure occurs by pressing a plane rigid surface against the 'hills', flattening their peaks, keeping the base area of the hills constant. To allow for a changing resistance to deformation, the contact stress is assumed to vary linearly with the shortening strain, to a first approximation. This model was tested against measurements of fracture closure and contact area of rough surfaces of calcite marble with a known initial height distribution of surface peaks. The fit to the data is quite good. In all cases, the model shows that closure is accompanied by a decrease in contact strength of deforming asperities, suggested also by the cataclastic deformation observed petrographically. The number of contact spots and the total length of contact seen in profile are also reasonably well modeled. These results have important implications for our understanding of frictional strength of fractures. The overall resistance to shear along rough surfaces depends upon the product of the shear strength and true area of the contacts, both of which are affected by normal stress. Application of this model approach shows that the initial frictional resistance of some fractures in ductile

  9. Total mercury in water and sediment from Honda Bay area in Palawan

    International Nuclear Information System (INIS)

    Kapauan, A.F.; Kapauan, P.A.; Tan, E.O.; Verceluz, F.P.

    1980-01-01

    This project is intended to pinpoint the sources of mercury contamination from the Honda Bay area in Palawan. Sampling sites were pinpointed which water and sediment samples were to be taken and kept in virgin polyethylene liter bottles. Analytical procedures were applied. The results of the analysis for total mercury content vary cosiderably from ml, less than 0.003 ng/9 to high of 0.419 ng/g with a considerable number of the sample going above the 0.100 ng/g level. Sediment samples also gave similar results, from a low of 0.004 ng/g to value higher than 2 ng/g round the jetty. It can be concluded, therefore, that the area surveyed is contaminated with mercury but not severely so. (author)

  10. Biomechanical Effects of Posterior Condylar Offset and Posterior Tibial Slope on Quadriceps Force and Joint Contact Forces in Posterior-Stabilized Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Kyoung-Tak Kang

    2017-01-01

    Full Text Available This study aimed to determine the biomechanical effect of the posterior condylar offset (PCO and posterior tibial slope (PTS in posterior-stabilized (PS fixed-bearing total knee arthroplasty (TKA. We developed ±1, ±2, and ±3 mm PCO models in the posterior direction and −3°, 0°, 3°, and 6° PTS models using a previously validated FE model. The influence of changes in the PCO and PTS on the biomechanical effects under deep-knee-bend loading was investigated. The contact stress on the PE insert increased by 14% and decreased by 7% on average as the PCO increased and decreased, respectively, compared to the neutral position. In addition, the contact stress on post in PE insert increased by 18% on average as PTS increased from −3° to 6°. However, the contact stress on the patellar button decreased by 11% on average as PTS increased from −3° to 6° in all different PCO cases. The quadriceps force decreased by 14% as PTS increased from −3° to 6° in all PCO models. The same trend was found in patellar tendon force. Changes in PCO had adverse biomechanical effects whereas PTS increase had positive biomechanical effects. However, excessive PTS should be avoided to prevent knee instability and subsequent failure.

  11. Occupational allergic contact dermatitis among construction workers in India

    Directory of Open Access Journals (Sweden)

    Sarma Nilendu

    2009-01-01

    Full Text Available Background: Allergic contact dermatitis is one of the important occupational hazards in construction workers and it often leads to poor quality of life of the workers with substantial financial loss. However, this is often a neglected entity. There are no past studies on the construction workers in Indian subcontinent. Objective: This pilot study has been done to assess the allergological profile among the workers engaged in construction of roads and bridges. Materials and Methods: The study was conducted among the workers working on construction of a bridge, flyover, and roads in West Bengal, India. Sixteen workers were selected on clinical suspicion. Ten were selected randomly and patch tested with Indian standard battery of patch test allergens. Analysis of reactions and relevance of positive test was assessed as per standard guidelines. Results: All the workers were men. Average age of workers was 24.8 years (range, 19-34 years. Dermatitis affected exposed parts in 93.75% and covered areas in 62.5%. Total positive test was 24 and relevant 11. Most common allergens were chromate (relevant allergy/RA: in 60% of patch tested workers, epoxy resin (RA: 30%, cobalt (RA: 20%, nickel (RA: 20%, thiuram mixture (RA: 10% and black rubber mix (RA: 10%. Two cases (20% had irritant contact dermatitis. Conclusion: The result indicated that chromate is the most frequent allergen among construction workers in this part of India. High frequency of involvement of the covered areas as well as the exposed areas highlighted the fact that the allergens had access to most body parts of the workers.

  12. Static friction in elastic adhesive MEMS contacts, models and experiment

    NARCIS (Netherlands)

    Tas, Niels Roelof; Gui, C.; Elwenspoek, Michael Curt

    2000-01-01

    Static friction in shearing mode can be expressed as the product of the shear strength of the interface and the real contact area. The influence of roughness on friction in elastic adhesive contact is analyzed. Special attention is paid to low loading conditions, in which the number of contact

  13. The contact sport of rough surfaces

    Science.gov (United States)

    Carpick, Robert W.

    2018-01-01

    Describing the way two surfaces touch and make contact may seem simple, but it is not. Fully describing the elastic deformation of ideally smooth contacting bodies, under even low applied pressure, involves second-order partial differential equations and fourth-rank elastic constant tensors. For more realistic rough surfaces, the problem becomes a multiscale exercise in surface-height statistics, even before including complex phenomena such as adhesion, plasticity, and fracture. A recent research competition, the “Contact Mechanics Challenge” (1), was designed to test various approximate methods for solving this problem. A hypothetical rough surface was generated, and the community was invited to model contact with this surface with competing theories for the calculation of properties, including contact area and pressure. A supercomputer-generated numerical solution was kept secret until competition entries were received. The comparison of results (2) provides insights into the relative merits of competing models and even experimental approaches to the problem.

  14. Modelo matemático para estimativa da área foliar total de bananeira 'Prata-anã' Esteem method of total leaf area of 'Prata anã' banana tree

    Directory of Open Access Journals (Sweden)

    Moises Zucoloto

    2008-12-01

    Full Text Available O objetivo deste trabalho foi desenvolver um modelo para estimar a área foliar total de bananeira, cultivar Prata-Anã, utilizando dimensões lineares da terceira folha, como o comprimento, a largura e o número total de folhas na emissão da inflorescência. As regressões lineares foram determinadas considerando-se a área foliar total de cada planta (AFT como variável dependente e o comprimento (C e a largura (L da terceira folha, o produto de CxL, o número total de folhas por planta (N e o produto de CxLxN como variáveis independentes. O modelo linear que melhor estimou a área foliar total (AFTe da bananeira 'Prata-Anã', ao nível de 5% de significância com R² de 0,89, foi a equação AFTe = 0,5187(CxLxN + 9603,5.The objective of this work was to estimate the total leaf area of banana, cultivar Prata Anã, according to the linear dimensions of the third leaf, such as the length and the width and the total number of leves in the inflorescence emission. The linear regressions were determined considering total leaf area of each plant (AFT such as dependent variable and the length (C and the width (L of the third leaf, the product of CxL, the total number of leaf per plant (N and the product of CxLxN as independent variables. The best linear model that estimated the total leaf area (AFTe of banana 'Prata Anã' at the level of 5% of significance with R² of 0,89 was the equation AFTe = 0.5187 (CxLxN + 9603.5.

  15. Large-Area Chemical Vapor Deposited MoS2 with Transparent Conducting Oxide Contacts toward Fully Transparent 2D Electronics

    KAUST Repository

    Dai, Zhenyu

    2017-09-08

    2D semiconductors are poised to revolutionize the future of electronics and photonics, much like transparent oxide conductors and semiconductors have revolutionized the display industry. Herein, these two types of materials are combined to realize fully transparent 2D electronic devices and circuits. Specifically, a large-area chemical vapor deposition process is developed to grow monolayer MoS2 continuous films, which are, for the first time, combined with transparent conducting oxide (TCO) contacts. Transparent conducting aluminum doped zinc oxide contacts are deposited by atomic layer deposition, with composition tuning to achieve optimal conductivity and band-offsets with MoS2. The optimized process gives fully transparent TCO/MoS2 2D electronics with average visible-range transmittance of 85%. The transistors show high mobility (4.2 cm2 V−1 s−1), fast switching speed (0.114 V dec−1), very low threshold voltage (0.69 V), and large switching ratio (4 × 108). To our knowledge, these are the lowest threshold voltage and subthreshold swing values reported for monolayer chemical vapor deposition MoS2 transistors. The transparent inverters show fast switching properties with a gain of 155 at a supply voltage of 10 V. The results demonstrate that transparent conducting oxides can be used as contact materials for 2D semiconductors, which opens new possibilities in 2D electronic and photonic applications.

  16. Static friction in elastic adhesion contacts in MEMS

    NARCIS (Netherlands)

    Tas, Niels Roelof; Gui, C.; Elwenspoek, Michael Curt

    2003-01-01

    Static friction in a shearing mode can be expressed as the product of the shear strength of the interface and the real contact area. The influence of roughness on friction in elastic adhesion contact is analyzed. The effect of adhesion is included using Maugis' expansion of the Greenwood and

  17. Performance evaluation of delefilcon a water gradient daily disposable contact lenses in first-time contact lens wearers.

    Science.gov (United States)

    Marx, Sebastian; Lauenborg, Bo; Kern, Jami R

    2018-02-06

    To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1 ® ) daily disposable contact lenses in first-time contact lens wearers. This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction. Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects' habitual spectacles during the day, at the end of the day, and overall (all p ≤ 0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p disposable contact lenses. Copyright © 2017. Published by Elsevier Ltd.

  18. Fluid load support and contact mechanics of hemiarthroplasty in the natural hip joint.

    Science.gov (United States)

    Pawaskar, Sainath Shrikant; Ingham, Eileen; Fisher, John; Jin, Zhongmin

    2011-01-01

    The articular cartilage covering the ends of the bones of diarthrodial synovial joints is thought to have evolved so that the loads are transferred under different and complex conditions, with a very high degree of efficiency and without compromising the structural integrity of the tissue for the life of an individual. These loading conditions stem from different activities such as walking, and standing. The integrity of cartilage may however become compromised due to congenital disease, arthritis or trauma. Hemiarthroplasty is a potentially conservative treatment when only the femoral cartilage is affected as in case of femoral neck fractures. In hemiarthroplasty, a metallic femoral prosthesis is used to articulate against the natural acetabular cartilage. It has also been hypothesized that biphasic lubrication is the predominant mechanism protecting the cartilage through a very high fluid load support which lowers friction. This may be altered due to hemiarthroplasty and have a direct effect on the frictional shear stresses and potentially cartilage degradation and wear. This study modelled nine activities of daily living and investigated the contact mechanics of a hip joint with a hemiarthroplasty, focussing particularly on the role of the fluid phase. It was shown that in most of the activities studied the peak contact stresses and peak fluid pressures were in the superior dome or lateral roof of the acetabulum. Total fluid load support was very high (~90%) in most of the activities which would shield the solid phase from being subjected to very high contact stresses. This was dependent not only on the load magnitude but also the direction and hence on the location of the contact area with respect to the cartilage coverage. Lower fluid load support was found when the contact area was nearer the edges where the fluid drained easily. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Design and fabrication stable LNF contact for future IC application

    International Nuclear Information System (INIS)

    Bhuiyan, M M I; Bhuiyan, M; Rashid, M M; Ahmed, Sayem; Kajihara, M

    2013-01-01

    Enable the design of a small contact spring for applications requiring high density, high speed and high durability. A low normal force (LNF) contact spring with high performance is fabricated using a unique combined MEMS photo resist lithography and electro fine forming (EFF) technology. Reducing a total contact material cost of a connector, a high-Hertz stress with LNF contact will be a key technology in the future. Only radius R 5μm tip with 0.1N force contact provides an excellent electrical performance which is much sharper than conventional contact. 0.30million cycle's durability test was passed at 300μm displacement and the contact resistance was ≤50mΩ

  20. Effect of the periphery of metal-semiconductor contacts with Schottky barriers on their static current-voltage characteristic

    International Nuclear Information System (INIS)

    Torkhov, N. A.

    2010-01-01

    Kelvin probe atomic-force microscopy of the electrostatic surface potential of gold Schottky contacts on n-GaAs showed that there is an extended transition area (halo) (tens of micrometers) around contacts in which the surface potential varies from the n-GaAs free surface potential to the gold contact surface potential. The contact potential and its distribution in the surrounding halo are controlled by the contact structure. The study of spreading currents showed that there is a high-conductance area (periphery) around the contact perimeter due to strong electric fields of the halo, which causes leakage currents. The conductivity of the main contact area is caused by 100- to 200-nm local areas with higher and lower conducting abilities. Mesa formation around contacts causes a decrease in the work function, a decrease in the halo extent and electric field strength, which is accompanied by spreading and decreasing of the peripheral area conductance. This results in disappearance of leakage currents and a decrease in the ideality index. In contrast, protection of the peripheral area by a SiO 2 insulating film 0.5 μm thick increases the work function, which is accompanied by the formation of potential lobes around the contact in two mutually perpendicular crystallographic directions. A stronger penetration of halo electric fields into the contact area results in an increase in the ideality index and disappearance of high-conductance peripheral area and leakage currents. The difference between the electrical properties of the periphery, gold grains, and their boundaries controls the contact switching mechanism when applying forward or reverse biases.

  1. Measurements methods and variability assesment of the Norway spruce total leaf area. Implications for remote sensing

    Czech Academy of Sciences Publication Activity Database

    Homolová, L.; Lukeš, Petr; Malenovský, Z.; Lhotáková, Z.; Kaplan, Věroslav; Hanuš, Jan

    2013-01-01

    Roč. 27, č. 1 (2013), s. 111-121 ISSN 0931-1890 R&D Projects: GA ČR GA205/09/ 1989 Institutional support: RVO:67179843 Keywords : chlorophyll content * conversion factor * Picea abies * projected leaf area * remote sensing * total leaf area Subject RIV: EH - Ecology, Behaviour Impact factor: 1.869, year: 2013

  2. Influence of the degree of thermal contact in fin and tube heat exchanger

    DEFF Research Database (Denmark)

    Singh, Shobhana; Sørensen, Kim; Condra, Thomas Joseph

    2016-01-01

    Present work aims to investigate the significance of thermal contact area between fins and tubes in a heat exchanger. The heat exchanger type selected for the study is a liquid-gas fin and tube heat exchanger. Four different cases namely I, II, III, and IV, based on a variable degree of thermal...... contact between fins and tubes are investigated. Case-I with 100% thermal contact area between the fin and tube is set as a reference to cases-II, III, and IV with a thermal contact area of approximately 70%, 50%, and 35%, respectively. Three-dimensional (3D) steady-state numerical models based on finite...... and to compare the performance of heat exchanger design in different cases. Comparative analysis indicates a significant influence of the degree of the thermal contact area between fin and tube on the overall performance. Case-I is found to have higher overall heat transfer coefficient of 47.332 W/(m2 K), higher...

  3. Optimization of Contact Force and Pull-in Voltage for Series based MEMS Switch

    Directory of Open Access Journals (Sweden)

    Abhijeet KSHIRSAGAR

    2010-04-01

    Full Text Available Cantilever based metal-to-metal contact type MEMS series switch has many applications namely in RF MEMS, Power MEMS etc. A typical MEMS switch consists of a cantilever as actuating element to make the contact between the two metal terminals of the switch. The cantilever is pulled down by applying a pull-in voltage to the control electrode that is located below the middle portion of the cantilever while only the tip portion of the cantilever makes contact between the two terminals. Detailed analysis of bending of the cantilever for different pull-in voltages reveals some interesting facts. At low pull-in voltage the cantilever tip barely touches the two terminals, thus resulting in very less contact area. To increase contact area a very high pull-in voltage is applied, but it lifts the tip from the free end due to concave curving of the cantilever in the middle region of the cantilever where the electrode is located. Again it results in less contact area. Furthermore, the high pull-in voltage produces large stress at the base of the cantilever close to the anchor. Therefore, an optimum, pull-in voltage must exist at which the concave curving is eliminated and contact area is maximum. In this paper authors report the finding of optimum contact force and pull-in voltage.

  4. Preliminary study of the uranium favorability of granitic and contact-metamorphic rocks of the Owens Valley area, Inyo and Mono Counties, California, and Esmeralda and Mineral Counties, Nevada

    International Nuclear Information System (INIS)

    Cupp, G.M.; Mitchell, T.P.

    1978-01-01

    Granitic and contact-metamorphic rocks of the Owens Valley area were sampled to determine their favorability for uranium. Uranium deposits associated with these rocks were examined to determine the mode of occurrence. Metamorphic rocks near contacts with intrusive rocks include skarns, schists, quartzites, metaconglomerates, hornfels, gneisses, and metavolcanics. The grade of contact metamorphism ranges from slight to intense, depending upon the distance from the intrusive contact. The average U 3 O 8 content of the metamorphic rock samples is 3 ppM. Metamorphic rock samples in a roof pendant at the Claw prospect contain as much as 3 percent U 3 O 8 . Skarn samples from the Birch Creek pluton contain as much as 114 ppM U 3 O 8 ; those from the Santa Rita Flat pluton contain as much as 23 ppM U 3 O 8 . Most of the intrusive rocks are granite, quartz monzonite, or monzonite. Granodiorite and diorite are less common, and gabbro is rare. The average U 3 O 8 content of the crystalline rock samples is 4 ppM. Samples from a quartz-monzonite pluton east of Lone Pine, California, and quartz monzonite in the Santa Rosa Hills had maximum contents of 28 and 13 ppM U 3 O 8 , respectively. Areas of contact metamorphism and metasomatism, such as those at the Claw prospect and Birch Creek pluton, are probably the most favorable sites for uranium deposits. There are many miles of granitic and contact-metamorphic zones in which undiscovered uranium deposits may exist. Although the overall uranium content of granitic rocks appears to be low, the pluton east of Lone Pine and the Hunter Mountain pluton in the area of the Santa Rosa Hills have sufficient uranium to have acted as uranium and detrital source rocks for uranium deposits that may now be buried in Tertiary sediments in the basins around the plutons. The Claw deposit is the only known uranium deposit of a size and grade to be of possible commercial interest

  5. Contact pressures and the impact of farm equipment on Latosol with the presence and absence of sugarcane straw

    Directory of Open Access Journals (Sweden)

    Reginaldo Barboza da Silva

    2016-06-01

    Full Text Available ABSTRACT High contact pressures applied to soil result in a greater degree of compaction, in addition to promoting other negative effects. The objective of this study was to quantify contact areas by using different methodologies, and pressures of farm equipment employed in production activity and evaluate structural changes caused in a Red Latosol with the presence and absence of straw cover. The design was completely randomized in a factorial scheme of type 4 (tire on front axle, tire on rear axle, tire on a sugarcane wagon and metallic track of sugar cane Harvester x 2 (presence and absence of straw. The contact area (CA of the run was obtained by three procedures: analytical measure of the area of an ellipse (CA1; digital measurement of area of an ellipse (CA2; and measurement of real contact area (RCA, with digital resources. The contact pressure was calculated from the ratio of mass of each machine's axle and the contact area of the run. The contact area obtained according to the procedure of the ellipse (CA1 and CA2 is overrated when compared to actual area obtained digitally (RCA. The straw reduces the contact pressure in the soil, due to the deep tire treads and consequently, increased contact area. Areas where the traffic of the machines occurred with soil covered with the presence of straw showed reduced soil resistance to penetration, cone index and pre-consolidation pressure, confirming that the increased contact area produced by straw reduced the pressure applied and the compression power dissipated in the soil.

  6. Unexpected current lowering of Mg contact on SI-GaAs

    International Nuclear Information System (INIS)

    Dubecky, F.; Bohacek, F.; Sekacova, M.; Hubik, P.; Kindl, D.; Gombia, E.; Necas, V.

    2016-01-01

    Four SI-GaAs surface barrier diodes with different contact metallization and/or contact areas were prepared and characterized in terms of the I-V measurements. The possibility of tuning their performance has been demonstrated by virtue of the device engineering, involving a low work-function Mg metallization and manipulation of the contact area. A device with a remarkable current lowering, by almost two orders of magnitude with respect to the 'standard' sample, was prepared. Such a possibility opens new application choices for SI-GaAs not recognized before. We suggest its use, with appropriate metal contact/s, in devices with a low current at low-voltage requirements, such as photonic devices, photodiodes or different physical sensors. The reported data and evidence from the existing literature rule out the widely accepted mechanism of ohmic/bulk-limited and thermionic emission transport as general rules for the interpretation of the low-bias regime in SI-GaAs diodes. The strong blocking ability of the low work function Mg contact was attributed to the downwards band bending, near contact charge carriers accumulation and the corresponding lowering of the bulk SI-GaAs free carrier concentration. (authors)

  7. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Science.gov (United States)

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  8. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  9. Contact parameter identification for vibrational response variability prediction

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester; Brunskog, Jonas; Jensen, Jakob Søndergaard

    2018-01-01

    industry, where the vibrational behavior of the structures within the hearing frequency range is critical for the performance of the devices. A procedure to localize the most probable contact areas and determine the most sensitive contact points with respect to variations in the modes of vibration......Variability in the dynamic response of assembled structures can arise due to variations in the contact conditions between the parts that conform them. Contact conditions are difficult to model accurately due to randomness in physical properties such as contact surface, load distribution...... or geometric details. Those properties can vary for a given structure due to the assembly and disassembly process, and also across nominally equal items that are produced in series. This work focuses on modeling the contact between small light-weight plastic pieces such as those used in the hearing aid...

  10. Establishing an upper bound on contact resistivity of ohmic contacts to n-GaN nanowires

    International Nuclear Information System (INIS)

    Blanchard, Paul; Bertness, Kris A; Harvey, Todd; Sanford, Norman

    2014-01-01

    Contact resistivity ρ c is an important figure of merit in evaluating and improving the performance of electronic and optoelectronic devices. Due to the small size, unique morphology, and uncertain transport properties of semiconductor nanowires (NWs), measuring ρ c of contacts to NWs can be particularly challenging. In this work, Si-doped n-GaN NWs were grown by molecular beam epitaxy. Four-contact structures with 20 nm Ti/200 nm Al contacts were fabricated on individual NWs by photolithography, and the contacts were annealed to achieve ohmic behavior. Two-point resistances R 23  and four-point collinear resistances R 23collinear  were measured between the middle two contacts on each NW. These resistances were then modeled by taking into account the non-uniform distribution of current flow along the length of each contact. Contrary to the assumption that the resistance difference R 23 −R 23collinear  is equal to the total contact resistance R c , the distributed-current-flow contact model shows that R 23 −R 23collinear  ≪ R c when ρ c is sufficiently small. Indeed, the measured R 23 −R 23collinear  was so small in these devices that it was within the measurement uncertainty, meaning that it was not possible to directly calculate ρ c from these data. However, it was possible to calculate an upper bound on ρ c for each device based on the largest possible value of R 23 −R 23collinear . In addition, we took into account the large uncertainties in the NW transport properties by numerically maximizing ρ c with respect to the uncertainty range of each measured and assumed parameter in the contact model. The resulting upper limits on ρ c ranged from 4.2 × 10 −6  to 7.6 × 10 −6  Ω cm 2 , indicating that 20 nm Ti/200 nm Al is a good choice of ohmic contact for moderately-doped n-GaN NWs. The measurement and numerical analysis demonstrated here offer a general approach to modeling ohmic contact resistivity via NW four

  11. 29 CFR 42.10 - Farm labor contact persons and regional coordinators (OSHA).

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Farm labor contact persons and regional coordinators (OSHA... contact persons and regional coordinators (OSHA). (a) OSHA Area Directors shall be responsible for... taken; and (2) migrant farmworker camp inspections are scheduled promptly. (b) OSHA Area Directors shall...

  12. Estimating Contact Exposure in Football Using the Head Impact Exposure Estimate

    OpenAIRE

    Kerr, Zachary Y.; Littleton, Ashley C.; Cox, Leah M.; DeFreese, J.D.; Varangis, Eleanna; Lynall, Robert C.; Schmidt, Julianne D.; Marshall, Stephen W.; Guskiewicz, Kevin M.

    2015-01-01

    Over the past decade, there has been significant debate regarding the effect of cumulative subconcussive head impacts on short and long-term neurological impairment. This debate remains unresolved, because valid epidemiological estimates of athletes' total contact exposure are lacking. We present a measure to estimate the total hours of contact exposure in football over the majority of an athlete's lifespan. Through a structured oral interview, former football players provided information rel...

  13. Stress distribution and contact area measurements of a gecko toe using a high-resolution tactile sensor.

    Science.gov (United States)

    Eason, Eric V; Hawkes, Elliot W; Windheim, Marc; Christensen, David L; Libby, Thomas; Cutkosky, Mark R

    2015-02-02

    The adhesive systems of geckos have been widely studied and have been a great source of bioinspiration. Load-sharing (i.e. preventing stress concentrations through equal distribution of loads) is necessary to maximize the performance of an adhesive system, but it is not known to what extent load-sharing occurs in gecko toes. In this paper, we present in vivo measurements of the stress distribution and contact area on the toes of a tokay gecko (Gekko gecko) using a custom tactile sensor with 100 μm spatial resolution. We found that the stress distributions were nonuniform, with large variations in stress between and within lamellae, suggesting that load-sharing in the tokay gecko is uneven. These results may be relevant to the understanding of gecko morphology and the design of improved synthetic adhesive systems.

  14. Stress distribution and contact area measurements of a gecko toe using a high-resolution tactile sensor

    International Nuclear Information System (INIS)

    Eason, Eric V; Hawkes, Elliot W; Christensen, David L; Cutkosky, Mark R; Windheim, Marc; Libby, Thomas

    2015-01-01

    The adhesive systems of geckos have been widely studied and have been a great source of bioinspiration. Load-sharing (i.e. preventing stress concentrations through equal distribution of loads) is necessary to maximize the performance of an adhesive system, but it is not known to what extent load-sharing occurs in gecko toes. In this paper, we present in vivo measurements of the stress distribution and contact area on the toes of a tokay gecko (Gekko gecko) using a custom tactile sensor with 100 μm spatial resolution. We found that the stress distributions were nonuniform, with large variations in stress between and within lamellae, suggesting that load-sharing in the tokay gecko is uneven. These results may be relevant to the understanding of gecko morphology and the design of improved synthetic adhesive systems. (paper)

  15. Contact resistance of ceramic interfaces between materials used for solid oxide fuel cell applications

    Energy Technology Data Exchange (ETDEWEB)

    Koch, S.

    2002-01-01

    The contact resistance can be divided into two main contributions. The small area of contact between ceramic components results in resistance due to current constriction. Resistive phases or potential barriers at the interface result in an interface contribution to the contact resistance, which may be smaller or larger than the constriction resistance. The contact resistance between pairs of three different materials were analysed (strontium doped lanthanum manganite, yttria stabilised zirconia and strontium and nickel doped lanthanum cobaltite), and the effects of temperature, atmosphere, polarisation and mechanical load on the contact resistance were investigated. The investigations revealed that the mechanical load of a ceramic contact has a high influence on the contact resistance, and generally power law dependence between the contact resistance and the mechanical load was found. The influence of the mechanical load on the contact resistance was ascribed to an area effect. The contact resistance of the investigated materials was dominated by current constriction at high temperatures. The measured contact resistance was comparable to the resistance calculated on basis of the contact areas found by optical and electron microscopy. At low temperatures, the interface contribution to the contact resistance was dominating. The cobaltite interface could be described by one potential barrier at the contact interface, whereas the manganite interfaces required several consecutive potential barriers to model the observed behaviour. The current-voltage behaviour of the YSZ contact interfaces was only weakly non-linear, and could be described by 22{+-}1 barriers in series. Contact interfaces with sinterable contact layers were also investigated, and the measured contact resistance for these interfaces were more than 10 times less than for the other interfaces. (au)

  16. Total water production capacity inversion phenomenon in multi-stage direct contact membrane distillation: A theoretical study

    KAUST Repository

    Lee, Jung Gil

    2017-09-09

    The low thermal efficiency and low water production are among the major challenges that prevent membrane distillation (MD) process from being commercialized. In an effort to design an efficient multi-stage direct contact MD (DCMD) unit through mathematical simulation, a new phenomenon that we refer to as total water production capacity inversion (WPI) has been detected. It is represented by a decrease in the total water production beyond a number of stages or a certain module length. WPI phenomenon, which was confirmed by using two different mathematical models validated experimentally, was found to take place due to the decrease in water vapor flux across the membrane as well as the increase in heat loss by conduction as the membrane length increases. Therefore, WPI should be considered as a critical MD design-criterion, especially for large scale units. Investigations conducted for a simulated multi-stage DCMD process showed that inlet feed and permeate temperatures difference, feed and permeate flow rates, and feed salinity have different effects on WPI. The number of stages (or module length at constant width) that leads to a maximum water production has been determined for different operating parameters. Decreasing inlet feed and permeate temperatures difference, or inlet feed and permeate flow rates and increasing inlet feed temperature at constant temperature difference or inlet feed salinity cause the WPI to take place at lower number of stages. Even though the feed salinity affects negligibly the mean permeate flux, it was clearly shown that it can affect WPI. The results presented herein unveil a hidden phenomenon that is likely to occur during process scale-up procedures and should be considered by process engineers for a proper choice of system design and operating conditions.

  17. Estimating Contact Exposure in Football Using the Head Impact Exposure Estimate.

    Science.gov (United States)

    Kerr, Zachary Y; Littleton, Ashley C; Cox, Leah M; DeFreese, J D; Varangis, Eleanna; Lynall, Robert C; Schmidt, Julianne D; Marshall, Stephen W; Guskiewicz, Kevin M

    2015-07-15

    Over the past decade, there has been significant debate regarding the effect of cumulative subconcussive head impacts on short and long-term neurological impairment. This debate remains unresolved, because valid epidemiological estimates of athletes' total contact exposure are lacking. We present a measure to estimate the total hours of contact exposure in football over the majority of an athlete's lifespan. Through a structured oral interview, former football players provided information related to primary position played and participation in games and practice contacts during the pre-season, regular season, and post-season of each year of their high school, college, and professional football careers. Spring football for college was also included. We calculated contact exposure estimates for 64 former football players (n = 32 college football only, n = 32 professional and college football). The head impact exposure estimate (HIEE) discriminated between individuals who stopped after college football, and individuals who played professional football (p < 0.001). The HIEE measure was independent of concussion history (p = 0.82). Estimating total hours of contact exposure may allow for the detection of differences between individuals with variation in subconcussive impacts, regardless of concussion history. This measure is valuable for the surveillance of subconcussive impacts and their associated potential negative effects.

  18. Contact area between femoral tunnel and interference screw in anatomic rectangular tunnel ACL reconstruction: a comparison of outside-in and trans-portal inside-out techniques.

    Science.gov (United States)

    Hiramatsu, Kunihiko; Mae, Tatsuo; Tachibana, Yuta; Nakagawa, Shigeto; Shino, Konsei

    2018-02-01

    The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3-5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel (P contact ratio than the TP technique after ART ACLR. Retrospective comparative study, Level III.

  19. Impact of the shape of geological contact on mining losses in the process of near-contact zone development

    Directory of Open Access Journals (Sweden)

    Г. С. Курчин

    2017-03-01

    Full Text Available In Russia development of mineral resources is carried out on a truly grand scale, and mining industry is in its essence a basic sector, supporting and facilitating the development of national economy. It predetermines the need of safe and responsible attitude towards riches of our subsoil – mineral resources. With this in mind, one of the key requirements to extraction technologies is minimization of mining losses and ore dilution.The biggest ore losses in the mining block take place in the process of development of contact areas between the ore body and surrounding rocks, due to differences between development pattern and surface of geological contact. Complexity of the contact between ore and surrounding rocks is traditionally characterized by so called «stochastic contact zone». Technological difficulty of extracting ore from the ore – wallrock contact is determined by volatility of geometric parameters in «stochastic contact zone» in the plane of geological contact.Current paper focuses on the issues of standard-setting for mining losses and ore dilution in the process of near-contact zone development. A method is suggested to estimate standard values of losses and ore dilution in stochastic zones. Authors have developed an algorithm of defining the shape of the contact. In the stochastic zone the contact can have a rectangular, sinusoidal, serrate and straight-line shapes. Research has established a relation between the contact shape and amounts of mining losses and ore dilution, formulas to calculate standard values are presented. Using suggested method, standard values for contact ore losses can be obtained in a quicker and more reliable way.

  20. Hydrodynamic instability induced liquid--solid contacts in film boiling

    International Nuclear Information System (INIS)

    Yao, S.; Henry, R.E.

    1976-01-01

    The film boiling liquid-solid contacts of saturated ethanol and water to horizontal flat gold plated copper are examined by using electric conductance probe. It is observed that the liquid-solid contacts occur over a wide temperature range, and generally, induced by hydrodynamic instabilities. The area of contact decreases exponentially with interface temperature and is liquid depth dependent. The averaged duration of contacts is strongly influenced by the dominant nucleation process, and thus, depends on the interface temperature and the wettability of the solid during the contact. The frequency of major contacts is about 1.5 times the bubble detaching frequency. It is found that the liquid-solid contacts may account for a large percentage of the film boiling heat transfer near the low temperature end of film boiling and decreases as the interface temperature increases

  1. Significance of neurovascular contact in classical trigeminal neuralgia

    DEFF Research Database (Denmark)

    Maarbjerg, Stine; Wolfram, Frauke; Gozalov, Aydin

    2015-01-01

    and degree of neurovascular contact. Severe neurovascular contact was defined as displacement or atrophy of the trigeminal nerve. A total of 135 patients with classical trigeminal neuralgia were included. Average age of disease onset was 53.0 years (95% confidence interval mean 40.5-55.5) and current age...... was 60.1 years (95% % confidence interval mean 57.5-62.7). Eighty-two (61%, 95% confidence interval 52-69%) patients were female. Neurovascular contact was prevalent both on the symptomatic and asymptomatic side [89% versus 78%, P = 0.014, odds ratio = 2.4 (1.2-4.8), P = 0.017], while severe...

  2. Children’s Contact With Their Incarcerated Parents

    Science.gov (United States)

    Poehlmann, Julie; Dallaire, Danielle; Loper, Ann Booker; Shear, Leslie D.

    2014-01-01

    Approximately 1.7 million children have parents who are incarcerated in prison in the United States, and possibly millions of additional children have a parent incarcerated in jail. Many affected children experience increased risk for developing behavior problems, academic failure, and substance abuse. For a growing number of children, incarcerated parents, caregivers, and professionals, parent– child contact during the imprisonment period is a key issue. In this article, we present a conceptual model to provide a framework within which to interpret findings about parent– child contact when parents are incarcerated. We then summarize recent research examining parent–child contact in context. On the basis of the research reviewed, we present initial recommendations for children’s contact with incarcerated parents and also suggest areas for future intervention and research with this vulnerable population. PMID:20822198

  3. Increasing coupling properties of locomotive by magnetizing contact area of wheel with rail

    Science.gov (United States)

    Antipin, D. Ya; Vorobyov, V. I.; Korchagin, V. O.; Kobishchanov, V. V.; Shorokhov, S. G.

    2017-10-01

    The authors of the paper consider a section of the magnetic circuit, which includes a band of a wheel pair, a railhead and an air gap between them. The parameters of the magnetic field and magnetic resistance between the wheel and the rail are obtained. Attention is paid to the decrease in the magnetic permeability of saturated steel regions and to the change in the magnetic susceptibility of the contact regions at high temperatures in the contact spot. The epicenters of the magnetic field concentration at different modes of magnetization are determined taking into account the change in the wheel position relative to the rail.

  4. Program Contacts for Northwest Indiana Area (Indiana)

    Science.gov (United States)

    Northwest Indiana Area (Indiana) of the Urban Waters Federal Partnership (UWFP) reconnects urban communities with their waterways by improving coordination among federal agencies and collaborating with community-led efforts.

  5. Numerical and experimental analysis of thermosonic bond strength considering interfacial contact phenomena

    International Nuclear Information System (INIS)

    He Jun; Guo Yongjin; Lin Zhongqin

    2008-01-01

    The theoretical equation of thermosonic bond strength involving interfacial deformation and microcontact phenomena is presented in this study. The constitutive equation of gold considering the ultrasonic softening mechanism was developed based on the thermosonic bonding experiments and coded into the FE software. The numerical model of bonding was established to estimate the surface exposure and the effective normal pressure. The real contact area was calculated by a microcontact model. Accordingly, the nominal bond strength can be obtained and verified by the experimental data. It is found that a better conjunction exists at the edge of the contact area because large surface exposure is produced there, which is also proved by the SEM image of a sheared ball bond. Increasing the bonding force or the ultrasonic power will increase the interfacial plastic deformation, the nominal and real contact areas, but decreases the effective normal pressure. The contact ratio increases to a maximum with the increase in the bonding force, and then decreases while it continues to decrease with the increase in the ultrasonic power. In addition, both the stress analysis and experimental result show that cratering and damage to the pad structure are easily produced below the edge region of the contact area under an excessive bonding force or ultrasonic power

  6. A Contact Pressure Analysis Comparing an All-Inside and Inside-Out Surgical Repair Technique for Bucket-Handle Medial Meniscus Tears.

    Science.gov (United States)

    Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B

    2017-10-01

    To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P contact pressure at all flexion angles (all P contact pressure at all flexion angles (all P contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P contact area at 60° and 90° and peak contact pressure at 90° (both P contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of

  7. Radionuclide contaminant analysis of small mammals at Area G, Technical Area 54, 1996 (with cumulative summary for 1994--1996)

    International Nuclear Information System (INIS)

    Biggs, J.R.; Bennett, K.D.; Fresquez, P.R.

    1997-07-01

    Small mammals were sampled at two waste burial sites at Area G, Technical Area (TA) 54 and a control site within the proposed Area G expansion area in 1996 to (1) identify radionuclides that are present within rodent tissues at waste burial sites, (2) to compare the amount of radionuclide uptake by small mammals at waste burial sites to a control site, and (3) to identify the primary mode of contamination to small mammals, either through surface contact or ingestion/inhalation. Three composite samples of approximately five animals per sample were collected at each site. Pelts and carcasses of each animal were separated and analyzed independently. Samples were analyzed for 241 Am, 90 Sr, 238 Pu, 239 Pu, total U, 137 Cs, and 3 H. Higher levels of total U, 241 Am, 238 Pu, and 239 Pu were detected in pelts as compared to the carcasses of small mammals at TA-54. Concentrations of other measured radionuclides in carcasses were nearly equal to or exceeded the mean concentrations in the pelts. Due to low sample sizes in total number of animals captured, statistical analysis to compare site to site could not be conducted. However, mean concentrations of total U, 238 Pu, 239 Pu, and 137 Cs in rodent carcasses were higher at Site 1 than site 2 or the Control Site and 241 Am was higher at Site 2 than Site 1 or the Control Site

  8. Three 3-axis accelerometers fixed inside the tyre for studying contact patch deformations in wet conditions

    Science.gov (United States)

    Niskanen, Arto J.; Tuononen, Ari J.

    2014-05-01

    The tyre-road contact area was studied visually by means of a high-speed camera and three accelerometers fixed to the inner liner of the tyre carcass. Both methods show a distorted contact area in wet conditions, but interesting differences appeared. First, the contact area in full aquaplaning seems strongly distorted on a glass plate when subjected to visual inspection, while the accelerometers indicate a more even hydrodynamic aquaplaning contact length (CL) across the tyre width. Secondly, the acceleration sensors predict the clear shortening of the CL of the tyre before the critical aquaplaning speed. It can be concluded that the visual contact area and shape are heavily dependent on the transparency of the liquid and smoothness of the glass. Meanwhile, the tyre sensors can provide a CL estimate on any road surface imaginable.

  9. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    Science.gov (United States)

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  10. The "Parachute" Technique: A Simple and Effective Single-Row Procedure to Achieve an Increased Contact Area Between the Cuff-Tendon and Its Footprint.

    Science.gov (United States)

    Natera, Luis; Consigliere, Paolo; Witney-Lagen, Caroline; Brugera, Juan; Sforza, Giuseppe; Atoun, Ehud; Levy, Ofer

    2017-10-01

    Many techniques of arthroscopic rotator cuff repair have been described. No significant differences in clinical outcomes or rerupture rates have been observed when comparing single-row with double-row methods. Not all single- and double-row repairs are the same. The details of the technique used are crucial. It has been shown that the suture-tendon interface is the weakest point of the reconstruction. Therefore, the biomechanical properties of rotator cuff repairs might be influenced more by the suture configuration than by the number of anchors or by the number of rows involved. Techniques that secure less amount of tendon over a smaller area of the healing zone might be expected to have higher failure rates. The way the sutures of the "parachute technique" are configured represents a quadruple mattress that increases the contact and pressure between the tendon and its footprint and increases the primary load to failure of the repair. We present a simple and effective single-row technique that involves the biomechanical and biological advantages related to the increased contact area and pressure between the cuff and its footprint.

  11. Improved contact metallization for high efficiency EFG polycrystalline silicon solar cells

    International Nuclear Information System (INIS)

    Dube, C.E.; Gonsiorawski, R.C.

    1990-01-01

    Improvements in the performance of polycrystalline silicon solar cells based on a novel, laser patterned contact process are described. Small lots of cells having an average conversion efficiency of 14 + %, with several cells approaching 15%, are reported for cells of 45 cm 2 area. The high efficiency contact design is based on YAG laser patterning of the silicon nitride anti-reflection coating. The Cu metallization is done using light-induced plating, with the cell providing the driving voltage for the plating process. The Cu electrodeposits into the laser defined windows in the AR coating for reduced contact area, following which the Cu bridges on top of the Ar coating to form a continuous finger pattern. The higher cell conversion efficiency is attributed to reduced shadow loss, higher junction quality, and reduced metal-semiconductor interfacial area

  12. Evaluation of a Surrogate Contact Model in Force-Dependent Kinematic Simulations of Total Knee Replacement

    NARCIS (Netherlands)

    Marra, M.A.; Andersen, M.S.; Damsgaard, M.; Koopman, B.; Janssen, D.W.; Verdonschot, N.J.

    2017-01-01

    Knowing the forces in the human body is of great clinical interest and musculoskeletal (MS) models are the most commonly used tool to estimate them in vivo. Unfortunately, the process of computing muscle, joint contact, and ligament forces simultaneously is computationally highly demanding. The goal

  13. Evaluation of a surrogate contact model in force-dependent kinematic simulations of total knee replacement

    NARCIS (Netherlands)

    Marra, Marco Antonio; Andersen, Michael S.; Damsgaard, Michael; Koopman, Bart F.J.M.; Janssen, Dennis; Verdonschot, Nico

    2017-01-01

    Knowing the forces in the human body is of great clinical interest and musculoskeletal (MS) models are the most commonly used tool to estimate them in vivo. Unfortunately, the process of computing muscle, joint contact, and ligament forces simultaneously is computationally highly demanding. The goal

  14. Optimal contact definition for reconstruction of Contact Maps

    Directory of Open Access Journals (Sweden)

    Stehr Henning

    2010-05-01

    Full Text Available Abstract Background Contact maps have been extensively used as a simplified representation of protein structures. They capture most important features of a protein's fold, being preferred by a number of researchers for the description and study of protein structures. Inspired by the model's simplicity many groups have dedicated a considerable amount of effort towards contact prediction as a proxy for protein structure prediction. However a contact map's biological interest is subject to the availability of reliable methods for the 3-dimensional reconstruction of the structure. Results We use an implementation of the well-known distance geometry protocol to build realistic protein 3-dimensional models from contact maps, performing an extensive exploration of many of the parameters involved in the reconstruction process. We try to address the questions: a to what accuracy does a contact map represent its corresponding 3D structure, b what is the best contact map representation with regard to reconstructability and c what is the effect of partial or inaccurate contact information on the 3D structure recovery. Our results suggest that contact maps derived from the application of a distance cutoff of 9 to 11Å around the Cβ atoms constitute the most accurate representation of the 3D structure. The reconstruction process does not provide a single solution to the problem but rather an ensemble of conformations that are within 2Å RMSD of the crystal structure and with lower values for the pairwise average ensemble RMSD. Interestingly it is still possible to recover a structure with partial contact information, although wrong contacts can lead to dramatic loss in reconstruction fidelity. Conclusions Thus contact maps represent a valid approximation to the structures with an accuracy comparable to that of experimental methods. The optimal contact definitions constitute key guidelines for methods based on contact maps such as structure prediction through

  15. Models of epidemics: when contact repetition and clustering should be included

    Directory of Open Access Journals (Sweden)

    Scholz Roland W

    2009-06-01

    Full Text Available Abstract Background The spread of infectious disease is determined by biological factors, e.g. the duration of the infectious period, and social factors, e.g. the arrangement of potentially contagious contacts. Repetitiveness and clustering of contacts are known to be relevant factors influencing the transmission of droplet or contact transmitted diseases. However, we do not yet completely know under what conditions repetitiveness and clustering should be included for realistically modelling disease spread. Methods We compare two different types of individual-based models: One assumes random mixing without repetition of contacts, whereas the other assumes that the same contacts repeat day-by-day. The latter exists in two variants, with and without clustering. We systematically test and compare how the total size of an outbreak differs between these model types depending on the key parameters transmission probability, number of contacts per day, duration of the infectious period, different levels of clustering and varying proportions of repetitive contacts. Results The simulation runs under different parameter constellations provide the following results: The difference between both model types is highest for low numbers of contacts per day and low transmission probabilities. The number of contacts and the transmission probability have a higher influence on this difference than the duration of the infectious period. Even when only minor parts of the daily contacts are repetitive and clustered can there be relevant differences compared to a purely random mixing model. Conclusion We show that random mixing models provide acceptable estimates of the total outbreak size if the number of contacts per day is high or if the per-contact transmission probability is high, as seen in typical childhood diseases such as measles. In the case of very short infectious periods, for instance, as in Norovirus, models assuming repeating contacts will also behave

  16. 5th Contact Mechanics International Symposium

    CERN Document Server

    2013-01-01

    Contact mechanics is an active research area with deep theoretical and numerical roots. The links between nonsmooth analysis and optimization with mechanics have been investigated intensively during the last decades, especially in Europe. The study of complementarity problems, variational -, quasivariational- and hemivariational inequalities arising in contact mechanics and beyond is a hot topic for interdisciplinary research and cooperation. The needs of industry for robust solution algorithms suitable for large scale applications and the regular updates of the respective elements in major commercial computational mechanics codes, demonstrate that this interaction is not restricted to the academic environment. The contributions of this book have been selected from the participants of the CMIS 2009 international conference which took place in Crete and continued a successful series of specialized contact mechanics conferences.

  17. Geohelminth contamination of public areas and epidemiological risk factors in Curitiba, Brazil

    Directory of Open Access Journals (Sweden)

    Lew Kan Sprenger

    Full Text Available This study aimed to investigate the frequency of geohelminthic contamination of public parks and squares in Curitiba, state of Paraná, Brazil, between August and December 2010. A total of 345 samples were collected from 69 sandboxes in different areas and were tested using the Faust, Lutz and Baermann parasitological techniques. Potential risk factors associated with soil contamination were also analyzed. A total of 36% of the samples (124/345 were positive for helminths and 65.2% of the areas (45/69 were classified as contaminated in one or more samples. The most commonly identified parasite eggs were Ancylostoma sp. (14.5%; 50/345; followed by Toxocara sp. (9.6%; 33/345 and the Strongyloidea superfamily (excluding hookworms (2.3%; 8/345. The analysis on the epidemiological risk factors indicated that the presence of dogs and feces in the sandboxes increased the chances of contamination of the site. Use of fences had a protective positive impact that reduced soil contamination. Health education programs should be applied within the community to minimize the risk of human contact with dogs' feces. Use of fencing in these areas is highly recommended to prevent or reduce the users' contact with animal excrement.

  18. Mind the Organelle Gap - Peroxisome Contact Sites in Disease.

    Science.gov (United States)

    Castro, Inês Gomes; Schuldiner, Maya; Zalckvar, Einat

    2018-03-01

    The eukaryotic cell is organized as a complex grid system where membrane-bound cellular compartments, organelles, must be localized to the right place at the right time. One way to facilitate correct organelle localization and organelle cooperation is through membrane contact sites, areas of close proximity between two organelles that are bridged by protein/lipid complexes. It is now clear that all organelles physically contact each other. The main focus of this review is contact sites of peroxisomes, central metabolic hubs whose defects lead to a variety of diseases. New peroxisome contacts, their tethering complexes and functions have been recently discovered. However, if and how peroxisome contacts contribute to the development of peroxisome-related diseases is still a mystery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Novel vertical silicon photodiodes based on salicided polysilicon trenched contacts

    International Nuclear Information System (INIS)

    Kaminski, Yelena; Shauly, Eitan; Paz, Yaron

    2015-01-01

    The classical concept of silicon photodiodes comprises of a planar design characterized by heavily doped emitters. Such geometry has low collection efficiency of the photons absorbed close to the surface. An alternative, promising, approach is to use a vertical design. Nevertheless, realization of such design is technologically challenged, hence hardly explored. Herein, a novel type of silicon photodiodes, based on salicided polysilicon trenched contacts, is presented. These contacts can be prepared up to 10 μm in depth, without showing any leakage current associated with the increase in the contact area. Consequently, the trenched photodiodes revealed better performance than no-trench photodiodes. A simple two dimensional model was developed, allowing to estimate the conditions under which a vertical design has the potential to have better performance than that of a planar design. At large, the deeper the trench is, the better is the vertical design relative to the planar (up to 10 μm for silicon). The vertical design is more advantageous for materials characterized by short diffusion lengths of the carriers. Salicided polysilicon trenched contacts open new opportunities for the design of solar cells and image sensors. For example, these contacts may passivate high contact area buried contacts, by virtue of the conformity of polysilicon interlayer, thus lowering the via resistance induced recombination enhancement effect

  20. Novel vertical silicon photodiodes based on salicided polysilicon trenched contacts

    Energy Technology Data Exchange (ETDEWEB)

    Kaminski, Yelena [Department of Chemical Engineering, Technion, Haifa (Israel); TowerJazz Ltd. Migdal Haemek (Israel); Shauly, Eitan [TowerJazz Ltd. Migdal Haemek (Israel); Paz, Yaron, E-mail: paz@tx.technion.ac.il [Department of Chemical Engineering, Technion, Haifa (Israel)

    2015-12-07

    The classical concept of silicon photodiodes comprises of a planar design characterized by heavily doped emitters. Such geometry has low collection efficiency of the photons absorbed close to the surface. An alternative, promising, approach is to use a vertical design. Nevertheless, realization of such design is technologically challenged, hence hardly explored. Herein, a novel type of silicon photodiodes, based on salicided polysilicon trenched contacts, is presented. These contacts can be prepared up to 10 μm in depth, without showing any leakage current associated with the increase in the contact area. Consequently, the trenched photodiodes revealed better performance than no-trench photodiodes. A simple two dimensional model was developed, allowing to estimate the conditions under which a vertical design has the potential to have better performance than that of a planar design. At large, the deeper the trench is, the better is the vertical design relative to the planar (up to 10 μm for silicon). The vertical design is more advantageous for materials characterized by short diffusion lengths of the carriers. Salicided polysilicon trenched contacts open new opportunities for the design of solar cells and image sensors. For example, these contacts may passivate high contact area buried contacts, by virtue of the conformity of polysilicon interlayer, thus lowering the via resistance induced recombination enhancement effect.

  1. Contact angle and local wetting at contact line.

    Science.gov (United States)

    Li, Ri; Shan, Yanguang

    2012-11-06

    This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.

  2. Prediction of medial and lateral contact force of the knee joint during normal and turning gait after total knee replacement.

    Science.gov (United States)

    Purevsuren, Tserenchimed; Dorj, Ariunzaya; Kim, Kyungsoo; Kim, Yoon Hyuk

    2016-04-01

    The computational modeling approach has commonly been used to predict knee joint contact forces, muscle forces, and ligament loads during activities of daily living. Knowledge of these forces has several potential applications, for example, within design of equipment to protect the knee joint from injury and to plan adequate rehabilitation protocols, although clinical applications of computational models are still evolving and one of the limiting factors is model validation. The objective of this study was to extend previous modeling technique and to improve the validity of the model prediction using publicly available data set of the fifth "Grand Challenge Competition to Predict In Vivo Knee Loads." A two-stage modeling approach, which combines conventional inverse dynamic analysis (the first stage) with a multi-body subject-specific lower limb model (the second stage), was used to calculate medial and lateral compartment contact forces. The validation was performed by direct comparison of model predictions and experimental measurement of medial and lateral compartment contact forces during normal and turning gait. The model predictions of both medial and lateral contact forces showed strong correlations with experimental measurements in normal gait (r = 0.75 and 0.71) and in turning gait trials (r = 0.86 and 0.72), even though the current technique over-estimated medial compartment contact forces in swing phase. The correlation coefficient, Sprague and Geers metrics, and root mean squared error indicated that the lateral contact forces were predicted better than medial contact forces in comparison with the experimental measurements during both normal and turning gait trials. © IMechE 2016.

  3. Effect of Complete Syndesmotic Disruption and Deltoid Injuries and Different Reduction Methods on Ankle Joint Contact Mechanics.

    Science.gov (United States)

    LaMothe, Jeremy; Baxter, Josh R; Gilbert, Susannah; Murphy, Conor I; Karnovsky, Sydney C; Drakos, Mark C

    2017-06-01

    Syndesmotic injuries can be associated with poor patient outcomes and posttraumatic ankle arthritis, particularly in the case of malreduction. However, ankle joint contact mechanics following a syndesmotic injury and reduction remains poorly understood. The purpose of this study was to characterize the effects of a syndesmotic injury and reduction techniques on ankle joint contact mechanics in a biomechanical model. Ten cadaveric whole lower leg specimens with undisturbed proximal tibiofibular joints were prepared and tested in this study. Contact area, contact force, and peak contact pressure were measured in the ankle joint during simulated standing in the intact, injured, and 3 reduction conditions: screw fixation with a clamp, screw fixation without a clamp (thumb technique), and a suture-button construct. Differences in these ankle contact parameters were detected between conditions using repeated-measures analysis of variance. Syndesmotic disruption decreased tibial plafond contact area and force. Syndesmotic reduction did not restore ankle loading mechanics to values measured in the intact condition. Reduction with the thumb technique was able to restore significantly more joint contact area and force than the reduction clamp or suture-button construct. Syndesmotic disruption decreased joint contact area and force. Although the thumb technique performed significantly better than the reduction clamp and suture-button construct, syndesmotic reduction did not restore contact mechanics to intact levels. Decreased contact area and force with disruption imply that other structures are likely receiving more loads (eg, medial and lateral gutters), which may have clinical implications such as the development of posttraumatic arthritis.

  4. Comparison of dwarf bamboos (Indocalamus sp.) leaf parameters to determine relationship between spatial density of plants and total leaf area per plant.

    Science.gov (United States)

    Shi, Pei-Jian; Xu, Qiang; Sandhu, Hardev S; Gielis, Johan; Ding, Yu-Long; Li, Hua-Rong; Dong, Xiao-Bo

    2015-10-01

    The relationship between spatial density and size of plants is an important topic in plant ecology. The self-thinning rule suggests a -3/2 power between average biomass and density or a -1/2 power between stand yield and density. However, the self-thinning rule based on total leaf area per plant and density of plants has been neglected presumably because of the lack of a method that can accurately estimate the total leaf area per plant. We aimed to find the relationship between spatial density of plants and total leaf area per plant. We also attempted to provide a novel model for accurately describing the leaf shape of bamboos. We proposed a simplified Gielis equation with only two parameters to describe the leaf shape of bamboos one model parameter represented the overall ratio of leaf width to leaf length. Using this method, we compared some leaf parameters (leaf shape, number of leaves per plant, ratio of total leaf weight to aboveground weight per plant, and total leaf area per plant) of four bamboo species of genus Indocalamus Nakai (I. pedalis (Keng) P.C. Keng, I. pumilus Q.H. Dai and C.F. Keng, I. barbatus McClure, and I. victorialis P.C. Keng). We also explored the possible correlation between spatial density and total leaf area per plant using log-linear regression. We found that the simplified Gielis equation fit the leaf shape of four bamboo species very well. Although all these four species belonged to the same genus, there were still significant differences in leaf shape. Significant differences also existed in leaf area per plant, ratio of leaf weight to aboveground weight per plant, and leaf length. In addition, we found that the total leaf area per plant decreased with increased spatial density. Therefore, we directly demonstrated the self-thinning rule to improve light interception.

  5. A survey of wheel-rail contact models for rail vehicles

    Science.gov (United States)

    Meymand, Sajjad Z.; Keylin, Alexander; Ahmadian, Mehdi

    2016-03-01

    Accurate and efficient contact models for wheel-rail interaction are essential for the study of the dynamic behaviour of a railway vehicle. Assessment of the contact forces and moments, as well as contact geometry provide a fundamental foundation for such tasks as design of braking and traction control systems, prediction of wheel and rail wear, and evaluation of ride safety and comfort. This paper discusses the evolution and the current state of the theories for solving the wheel-rail contact problem for rolling stock. The well-known theories for modelling both normal contact (Hertzian and non-Hertzian) and tangential contact (Kalker's linear theory, FASTSIM, CONTACT, Polach's theory, etc.) are reviewed. The paper discusses the simplifying assumptions for developing these models and compares their functionality. The experimental studies for evaluation of contact models are also reviewed. This paper concludes with discussing open areas in contact mechanics that require further research for developing better models to represent the wheel-rail interaction.

  6. Children in Greenland: disease patterns and contacts to the health care system

    Directory of Open Access Journals (Sweden)

    Marius Kløvgaard

    2016-12-01

    Full Text Available Background: Previous studies of Greenlandic children’s disease pattern and contacts to the health care system are sparse and have focused on the primary health care sector. Objective: We aimed to identify the disease pattern and use of health care facilities of children aged 0–10 in two Greenlandic cohorts. Methods and design: In a retrospective, descriptive follow-up of the Ivaaq (The Greenland Child Cohort and the CLEAR (climate changes, environmental contaminants and reproductive health birth cohorts (total n=1,000, we reviewed medical records of children aged 6–10 in 2012 with residence in Nuuk or Ilulissat (n=332. Data on diseases and health care system contacts were extracted. Diagnoses were validated retrospectively. Primary health care contacts were reviewed for a random sample of 1:6. Results: In 311 children with valid social security number, the total number of health care system contacts was 12,471 equalling 4.6 contacts per child per year. The annual incidence rate of hospital admissions was 1:10 children (total n=266, 1,220 days, 4.6 days/admission, outpatient contacts 2:10 children and primary care 3.6 per child. Contacts were overall more frequent in boys compared with girls, 39.5 versus 34.6 during the study period, p=0.02. The highest annual contact rates for diseases were: hospitalisations/acute respiratory diseases 13.9:1,000; outpatient contacts/otitis media 5.1:1,000; primary care/conjunctivitis or nasopharyngitis 410:1,000 children. Outpatient screening for respiratory tuberculosis accounted 6.2:1,000, primary care non-disease (Z-diagnosis 2,081:1,000 annually. Complete adherence to the child vaccination programme was seen in 40%, while 5% did not receive any vaccinations. Conclusions: In this first study of its kind, the health care contact pattern in Greenlandic children showed a relatively high hospitalisation rate and duration per admission, and a low primary health care contact rate. The overall contact rate and

  7. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users

    Directory of Open Access Journals (Sweden)

    Deeksha V Thakur

    2014-01-01

    Full Text Available Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200 were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey′s agar and Sabouraud′s dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62% and lens care solution (42%, respectively. The most frequently isolated contaminant was Staphylococcus aureus (21% followed by Pseudomonas species (19.5%. Majority (64% of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75% ( p0 <0.05. Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

  8. Contact and Non-contact Measurements of Grinding Pins

    Directory of Open Access Journals (Sweden)

    Magdziak Marek

    2015-01-01

    Full Text Available The paper presents the results of contact and non-contact measurements of external profiles of selected grinding pins. The measurements were conducted in order to choose the appropriate measuring technique in the case of the considered measurement task. In the case of contact measurements the coordinate measuring machine ACCURA II was applied. The used coordinate measuring machine was equipped with the contact scanning probe VAST XT and the Calypso inspection software. Contact coordinate measurements were performed by using of different measurement strategies. The applied strategies included different scanning velocities and distances between measured points. Non-contact measurements were conducted by means of the tool presetter produced by the Mahr company. On the basis of gained results the guidelines concerning measurements of grinding pins were formulated. The measurements of analyzed grinding pins performed by means of the non-contact measuring system are characterized by higher reproducibility than the contact measurements. The low reproducibility of contact measurements may be connected with the inaccuracy of the selected coordinate measuring machine and the measuring probe, the measurement parameters and environmental conditions in the laboratory where the coordinate measuring machine is located. Moreover, the paper presents the possible application of results of conducted investigations. The results of non-contact measurements can be used in the simulation studies of grinding processes. The simulations may reduce the costs of machining processes.

  9. Motivation for social contact in horses measured by operant conditioning

    DEFF Research Database (Denmark)

    Søndergaard, Eva; Jensen, Margit Bak; Nicol, Christine J.

    2011-01-01

    and muzzle contact, respectively, to a familiar companion horse. Horses were housed individually next to their companion horse and separations between pens prevented physical contact. During daily test sessions horses were brought to a test area where they could access an arena allowing social contact. Arena......Although horses are social animals they are often housed individually with limited social contact to other horses and this may compromise their welfare. The present study included eight young female horses and investigated the strength of motivation for access to full social contact, head contact...... test session was recorded. All horses could access all three types of social contact in a cross-over design, and an empty arena was used as control. Motivational strength was assessed using elasticity of demand functions, which were estimated based on the number of rewards earned and FR. Elasticities...

  10. Consumption-based Total Suspended Particulate Matter Emissions in Jing-Jin-Ji Area of China

    Science.gov (United States)

    Yang, S.; Chen, S.; Chen, B.

    2014-12-01

    The highly-industrialized regions in China have been facing a serious problem of haze mainly consisted of total suspended particulate matter (TSPM), which has attracted great attention from the public since it directly impairs human health and clinically increases the risks of various respiratory and pulmonary diseases. In this paper, we set up a multi-regional input-output (MRIO) model to analyze the transferring routes of TSPM emissions between regions through trades. TSPM emission from particulate source regions and sectors are identified by analyzing the embodied TSPM flows through monetary flow and carbon footprint. The track of TSPM from origin to end via consumption activities are also revealed by tracing the product supply chain associated with the TSPM emissions. Beijing-Tianjin-Hebei (Jing-Jin-Ji) as the most industrialized area of China is selected for a case study. The result shows that over 70% of TSPM emissions associated with goods consumed in Beijing and Tianjin occurred outside of their own administrative boundaries, implying that Beijing and Tianjin are net embodied TSPM importers. Meanwhile, 63% of the total TSPM emissions in Hebei Province are resulted from the outside demand, indicating Hebei is a net exporter. In addition, nearly half of TSPM emissions are the by-products related to electricity and heating supply and non-metal mineral products in Jing-Jin-Ji Area. Based on the model results, we provided new insights into establishing systemic strategies and identifying mitigation priorities to stem TSPM emissions in China. Keywords: total suspended particulate matter (TSPM); urban ecosystem modeling; multi-regional input-output (MRIO); China

  11. Prediction of static friction coefficient in rough contacts based on the junction growth theory

    Science.gov (United States)

    Spinu, S.; Cerlinca, D.

    2017-08-01

    The classic approach to the slip-stick contact is based on the framework advanced by Mindlin, in which localized slip occurs on the contact area when the local shear traction exceeds the product between the local pressure and the static friction coefficient. This assumption may be too conservative in the case of high tractions arising at the asperities tips in the contact of rough surfaces, because the shear traction may be allowed to exceed the shear strength of the softer material. Consequently, the classic frictional contact model is modified in this paper so that gross sliding occurs when the junctions formed between all contacting asperities are independently sheared. In this framework, when the contact tractions, normal and shear, exceed the hardness of the softer material on the entire contact area, the material of the asperities yields and the junction growth process ends in all contact regions, leading to gross sliding inception. This friction mechanism is implemented in a previously proposed numerical model for the Cattaneo-Mindlin slip-stick contact problem, which is modified to accommodate the junction growth theory. The frictionless normal contact problem is solved first, then the tangential force is gradually increased, until gross sliding inception. The contact problems in the normal and in the tangential direction are successively solved, until one is stabilized in relation to the other. The maximum tangential force leading to a non-vanishing stick area is the static friction force that can be sustained by the rough contact. The static friction coefficient is eventually derived as the ratio between the latter friction force and the normal force.

  12. Industrially feasible, dopant-free, carrier-selective contacts for high-efficiency silicon solar cells

    KAUST Repository

    Yang, Xinbo; Weber, Klaus; Hameiri, Ziv; De Wolf, Stefaan

    2017-01-01

    quality and cell processing, a remarkable efficiency of 22.1% has been achieved using an n-type silicon solar cell featuring a full-area TiO contact. Next, we demonstrate the compatibility of TiO contacts with an industrial contact-firing process, its low

  13. Characteristics of total gaseous mercury concentrations at a coastal area of the Yangtze Delta, China.

    Science.gov (United States)

    Diao, Chunyan; Li, Jianfeng; Zhang, Bin; Tang, Shichuang

    2017-03-01

    In this study, we report on total gaseous mercury (TGM) field observations made in the rural area of Shanghai, Chongming Island, China, from September 2009 to April 2012. The average TGM was 2.65 ± 1.73 ng m -3 in Chongming Island, which is higher than the TGM background value of the Northern Hemisphere (1.5-1.7 ng m -3 ); this indicates that to some extent, the Chongming area has been affected by anthropogenic mercury emissions. The observed TGM follows a seasonal pattern; concentrations are highest in winter, followed by autumn, summer, and spring. There is also a clear diurnal variation in TGM. All peak values appear between 7:00 and 9:00 in all four seasons; this appears to be the result of the height change in the atmospheric boundary layer that occurs between day and night. TGM concentrations in Chongming remain high in the westerly wind direction, especially in the southwest direction because of its low frequency, so the greatest source contribution to TGM in Chongming lies to the northwest. Wind speed is also a significant factor affecting TGM, and was negatively correlated with TGM concentrations. TGM is also closely related to carbon monoxide (CO) concentrations, indicating that TGM is impacted by human activities. The slope of the linear fitting of TGM and CO demonstrates that the contribution of noncoal source emissions to TGM in summer is greater than in autumn, mainly because the high temperature and intensive sunlight in summer increase mercury emissions from natural sources. Except for some studies in the coastal areas (e.g., Kang Hwa Island by Kim et al., 2006, An-Myun Island by Kim et al., 2002, and Okinawa by Chan et al., 2008), data specifically for coastal areas are lacking. Monitoring of total gaseous mercury (TGM) in the rural area of Shanghai, Chongming Island, can help us understand mercury distribution.

  14. Contact dermatitis in cement workers in Isfahan

    Directory of Open Access Journals (Sweden)

    Iraji Fariba

    2006-01-01

    Full Text Available BACKGROUND: Due to recent industrialization and inadequately protected workers or in other words poor supervision on constructive workers habits in our large city of Isfahan cement contact dermatitis is relatively high especially among cement factory workers and constructive personnel. PURPOSES: To investigate the prevalence rate of cement contact dermatitis in cement factory workers in Isfahan. METHODS: A case-control clinical study was carried out by randomly selecing 150 factory workders and 150 official clerks in a cement factory in Isfahan in 2001. After a complete physical examination, data was recorded in observational checklists. FINDINGS: The percentages of contact dermatitis prevalences in the first and the second groups were 22% and 5.3% respectively. About 60% of cement workers with contact dermatitis were between 30-40 years of age. There was a direct relationship with age in both groups of the workers. In the high-exposure group, the hand eczema along was 70% but in the other group the percentage of involvement was the same in exposed and unexposed anatomical areas. CONCLUSIONS: There was a direct relationship between occurrence and the severity of involvement and duration of contact in the first group. Cent percent of cement workers had contact dermatitis after 10 or less years, but the percentage among the other group was 35%. LIMITATION: Irritant contact dermatitis to cement has not been detected.

  15. Fragrance contact allergy in Iran.

    Science.gov (United States)

    Firooz, A; Nassiri-Kashani, M; Khatami, A; Gorouhi, F; Babakoohi, S; Montaser-Kouhsari, L; Davari, P; Dowlati, Y

    2010-12-01

    Fragrances are considered as one of the most common causes of allergic contact dermatitis. About 1-4% of the general population suffer from fragrance contact allergy (FCA). To determine the frequency of FCA and its clinical relevance in a sample of Iranian patients with history of contact and/or atopic dermatitis from January 2004 to December 2008. Standardized patch testing with 28-allergen screening series recommended by the German Contact Dermatitis Research Group and European Standard Series was used at six dermatological clinics in Iran. Fragrance allergens comprised of fragrance mix I (FM I), Myroxylon pereirae (MP; balsam of Peru), Lyral, turpentine and FM II. Fragrance contact allergy was detected in 7.2% of the patients. The frequency of positive reactions to FM I, MP and FM II were 3.7% (41/1105), 2.8% (32/1135) and 1.1% (3/267) respectively. 82.4% of the reactions to fragrance allergens were clinically relevant. The most common involved areas were hands (68.4%) and face (35.4%). Fragrance allergy predominantly affected women aged more than 40 years (P=0.008). Positive reaction to more than two allergens was significantly higher in FCA patients compared with other contact dermatitis patients (P<0.0001), and FM I, nickel and MP were the most frequent allergens in these patients. Despite less frequency of FCA in comparison with some European countries, its clinical relevance in Iranian patients seems to be high. It mostly affects the hands and the face predominantly in women aged more than 40 years. © 2010 The Authors. Journal compilation © 2010 European Academy of Dermatology and Venereology.

  16. Adherens junction distribution mechanisms during cell-cell contact elongation in Drosophila.

    Directory of Open Access Journals (Sweden)

    Gabrielle Goldenberg

    Full Text Available During Drosophila gastrulation, amnioserosa (AS cells flatten and spread as an epithelial sheet. We used AS morphogenesis as a model to investigate how adherens junctions (AJs distribute along elongating cell-cell contacts in vivo. As the contacts elongated, total AJ protein levels increased along their length. However, genetically blocking this AJ addition indicated that it was not essential for maintaining AJ continuity. Implicating other remodeling mechanisms, AJ photobleaching revealed non-directional lateral mobility of AJs along the elongating contacts, as well as local AJ removal from the membranes. Actin stabilization with jasplakinolide reduced AJ redistribution, and live imaging of myosin II along elongating contacts revealed fragmented, expanding and contracting actomyosin networks, suggesting a mechanism for lateral AJ mobility. Actin stabilization also increased total AJ levels, suggesting an inhibition of AJ removal. Implicating AJ removal by endocytosis, clathrin endocytic machinery accumulated at AJs. However, dynamin disruption had no apparent effect on AJs, suggesting the involvement of redundant or dynamin-independent mechanisms. Overall, we propose that new synthesis, lateral diffusion, and endocytosis play overlapping roles to populate elongating cell-cell contacts with evenly distributed AJs in this in vivo system.

  17. Mapping contact metamorphic aureoles in Extremadura, Spain, using Landsat thematic mapper images

    Science.gov (United States)

    Rowan, L.C.; Anton-Pacheco, C.; Brickey, D.W.; Kingston, M.J.; Payas, A.

    1987-01-01

    In the Extremadura region of western Spain, Ag, Pb, Zn, and Sn deposits occur in the pieces of late Hercynian granitic plutons and near the pluton contacts in late Proterozoic slate and metagraywacke that have been regionally metamorphosed to the green schist facies. The plutons generally are well exposed and have distinctive geomorphological expression and vegetation; poor exposures of the metasedimentary host rocks and extensive cultivation, however, make delineation of the contact aureoles difficult. Landsat Thematic Mapper (TM) images have been used to distinguish soil developed on the contact metamorphic rocks from soil formed on the stratigraphically equivalent slate-metagraywacke sequence. The mineral constituents of these soils are similar, except that muscovite is more common in the contact metamorphic soil; carbonaceous material is common in both soils. Contact metamorphic soil have lower reflectance, especially in the 1.6-micrometers wavelength region (TM 5), and weaker Al-OH, Mg-OH, and Fe3+ absorption features than do spectra of the slate-metagraywacke soil. The low-reflectance and subdued absorption features exhibited by the contact metamorphic soil spectra are attributed to the high absorption coefficient f the carbonaceous material caused by heating during emplacement of the granitic plutons. These spectral differences are evident in a TM 4/3, 4/5, 3/1 color-composite image. Initially, this image was used to outline the contact aureoles, but digital classification of the TM data was necessary for generating internally consistent maps of the distribution of the exposed contact metamorphic soil. In an August 1984, TM scene of the Caceras area, the plowed, vegetation-free fields were identified by their low TM 4/3 values. Then, ranges of TM 4/5 and 3/1 values were determine for selected plower fields within and outside the contact aureoles; TM 5 produced results similar to TM 4/5. Field evaluation, supported by X-ray diffraction and petrographic

  18. Viscoelastic reciprocating contacts in presence of finite rough interfaces: A numerical investigation

    Science.gov (United States)

    Putignano, Carmine; Carbone, Giuseppe

    2018-05-01

    Viscoelastic reciprocating contacts are crucial in a number of systems, ranging from sealing components to viscoelastic dampers. Roughness plays in these conditions a central role, but no exhaustive assessment in terms of influence on area, separation and friction has been drawn so far. This is due to the huge number of time and space scales involved in the problem. By means of an innovative Boundary Element methodology, which treats the time as a parameter and then requires only to discretize the space domain, we investigate the viscoelastic reciprocating contact mechanics between rough solids. In particular, we consider the alternate contact of a rigid finite-size rough punch over a viscoelastic layer: the importance of the domain finiteness in the determination of the contact area and the contact solution anisotropy is enlightened. Implications on real system may be drawn on this basis. Finally, we focus on the hysteretic cycle related to the viscoelastic tangential forces.

  19. Effect of surface texturing on superoleophobicity, contact angle hysteresis, and "robustness".

    Science.gov (United States)

    Zhao, Hong; Park, Kyoo-Chul; Law, Kock-Yee

    2012-10-23

    Previously, we reported the creation of a fluorosilane (FOTS) modified pillar array silicon surface comprising ~3-μm-diameter pillars (6 μm pitch with ~7 μm height) that is both superhydrophobic and superoleophobic, with water and hexadecane contact angles exceeding 150° and sliding angles at ~10° owing to the surface fluorination and the re-entrant structure in the side wall of the pillar. In this work, the effects of surface texturing (pillar size, spacing, and height) on wettability, contact angle hysteresis, and "robustness" are investigated. We study the static, advancing, and receding contact angles, as well as the sliding angles as a function of the solid area fraction. The results reveal that pillar size and pillar spacing have very little effect on the static and advancing contact angles, as they are found to be insensitive to the solid area fraction from 0.04 to ~0.4 as the pillar diameter varies from 1 to 5 μm and the center-to-center spacing varies from 4.5 to 12 μm. On the other hand, sliding angle, receding contact angle, and contact angle hysteresis are found to be dependent on the solid area fraction. Specifically, receding contact angle decreases and sliding angle and hysteresis increase as the solid area fraction increases. This effect can be attributable to the increase in pinning as the solid area fraction increases. Surface Evolver modeling shows that water wets and pins the pillar surface whereas hexadecane wets the pillar surface and then penetrates into the side wall of the pillar with the contact line pinning underneath the re-entrant structure. Due to the penetration of the hexadecane drop into the pillar structure, the effect on the receding contact angle and hysteresis is larger relative to that of water. This interpretation is supported by studying a series of FOTS pillar array surfaces with varying overhang thickness. With the water drop, the contact line is pinned on the pillar surface and very little overhang thickness effect

  20. An elastic-plastic contact model for line contact structures

    Science.gov (United States)

    Zhu, Haibin; Zhao, Yingtao; He, Zhifeng; Zhang, Ruinan; Ma, Shaopeng

    2018-06-01

    Although numerical simulation tools are now very powerful, the development of analytical models is very important for the prediction of the mechanical behaviour of line contact structures for deeply understanding contact problems and engineering applications. For the line contact structures widely used in the engineering field, few analytical models are available for predicting the mechanical behaviour when the structures deform plastically, as the classic Hertz's theory would be invalid. Thus, the present study proposed an elastic-plastic model for line contact structures based on the understanding of the yield mechanism. A mathematical expression describing the global relationship between load history and contact width evolution of line contact structures was obtained. The proposed model was verified through an actual line contact test and a corresponding numerical simulation. The results confirmed that this model can be used to accurately predict the elastic-plastic mechanical behaviour of a line contact structure.

  1. Bimetallic nanoparticles for surface modification and lubrication of MEMS switch contacts

    International Nuclear Information System (INIS)

    Patton, Steven T; Hu Jianjun; Slocik, Joseph M; Campbell, Angela; Naik, Rajesh R; Voevodin, Andrey A

    2008-01-01

    Reliability continues to be a critical issue in microelectromechanical systems (MEMS) switches. Failure mechanisms include high contact resistance (R), high adhesion, melting/shorting, and contact erosion. Little previous work has addressed the lubrication of MEMS switches. In this study, bimetallic nanoparticles (NPs) are synthesized using a biotemplated approach and deposited on Au MEMS switch contacts as a nanoparticle-based lubricant. Bimetallic nanoparticles are comprised of a metallic core (∼10 nm diameter gold nanoparticle) with smaller metallic nanoparticles (∼2-3 nm diameter Pd nanoparticles) populating the core surface. Adhesion and resistance (R) were measured during hot switching experiments at low (10 μA) and high (1 mA) current. The Au/Pd NP coated contacts led to reduced adhesion as compared to pure Au contacts with a compromise of slightly higher R. For switches held in the closed position at low current, R gradually decreased over tens of seconds due to increased van der Waals force and growth of the real area of contact with temporal effects being dominant over load effects. Contact behavior transitioned from 'Pd-like' to 'Au-like' during low current cycling experiments. Melting at high current resulted in rapid formation of large real contact area, low and stable R, and minimal effect of load on R. Durability at high current was excellent with no failure through 10 6 hot switching cycles. Improvement at high current is due to controlled nanoscale surface roughness that spreads current through multiple nanocontacts, which restricts the size of melting regions and causes termination of nanowire growth (prevents shorting) during contact opening. Based on these results, bimetallic NPs show excellent potential as surface modifiers/lubricants for MEMS switch contacts

  2. The loaded surface profile: a new technique for the investigation of contact surfaces

    OpenAIRE

    McBride, J.W.

    2006-01-01

    Contact between rough surfaces produces a complex contact profile. The contact area is usually estimated according to roughness statistics in conjunction withsurface models or by examining the surfaces before and after contact. Most of the existing literature on loaded surface profiles is theoretical or numerical in nature. This paper presents a methodology for a new system to measure the loaded surface profile, based on a non-contact 3D laser profiler. The system allows the measurement of...

  3. Review on prevention of bacterial adhesion on contact lens using plasma treatment

    Science.gov (United States)

    Ramli, N. A. H.; Zaaba, S. K.; Mustaffa, M. T.; Zakaria, A.; Shahriman A., B.

    2017-03-01

    Many researches had been conducted to enhance the properties of contact lens. Most of the research conducted discussed on the factors that affect the adhesion process to contact lenses, rate of contact lens contamination, and type of microbe that adhere on the contact lens surface and contact lens casing. Studies on the proposed strategies or technology that can be used to slower down the formation of bacteria on contact lens are being explored. New technologies or strategies to prevent or slow down the adhesion of bacteria on contact lens have become a priority in this area. This review paper covers two main aspects, namely factor that affect the bacteria adhesion on contact lens and also the introduction of plasma treatment as a potential method for contact lens treatment.

  4. Equilibrium contact angle or the most-stable contact angle?

    Science.gov (United States)

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  5. Culicoides (Diptera: Ceratopogonidae) midges, the vectors of African horse sickness virus--a host/vector contact study in the Niayes area of Senegal.

    Science.gov (United States)

    Fall, Moussa; Diarra, Maryam; Fall, Assane G; Balenghien, Thomas; Seck, Momar T; Bouyer, Jérémy; Garros, Claire; Gimonneau, Geoffrey; Allène, Xavier; Mall, Iba; Delécolle, Jean-Claude; Rakotoarivony, Ignace; Bakhoum, Mame T; Dusom, Ange M; Ndao, Massouka; Konaté, Lassana; Faye, Ousmane; Baldet, Thierry

    2015-01-21

    African horse sickness (AHS) is an equine disease endemic to Senegal. The African horse sickness virus (AHSV) is transmitted to the mammalian hosts by midges of the Culicoides Latreille genus. During the last epizootic outbreak of AHS in Senegal in 2007, 1,169 horses died from this disease entailing an estimated cost of 1.4 million euros. In spite of the serious animal health and economic implications of AHS, very little is known about determinants involved in transmission such as contact between horses and the Culicoides species suspected of being its vectors. The monthly variation in host/vector contact was determined in the Niayes area, Senegal, an area which was severely affected by the 2007 outbreak of AHS. A horse-baited trap and two suction light traps (OVI type) were set up at each of five sites for three consecutive nights every month for one year. Of 254,338 Culicoides midges collected 209,543 (82.4%) were female and 44,795 (17.6%) male. Nineteen of the 41 species collected were new distribution records for Senegal. This increased the number of described Culicoides species found in Senegal to 53. Only 19 species, of the 41 species found in light trap, were collected in the horse-baited trap (23,669 specimens) largely dominated by Culicoides oxystoma (22,300 specimens, i.e. 94.2%) followed by Culicoides imicola (482 specimens, i.e. 2.0%) and Culicoides kingi (446 specimens, i.e. 1.9%). Culicoides oxystoma should be considered as a potential vector of AHSV in the Niayes area of Senegal due to its abundance on horses and its role in the transmission of other Culicoides-borne viruses.

  6. Multiple contacts with diversion at the point of arrest.

    Science.gov (United States)

    Riordan, Sharon; Wix, Stuart; Haque, M Sayeed; Humphreys, Martin

    2003-04-01

    A diversion at the point of arrest (DAPA) scheme was set up in five police stations in South Birmingham in 1992. In a study of all referrals made over a four-year period a sub group of multiple contact individuals was identified. During that time four hundred and ninety-two contacts were recorded in total, of which 130 were made by 58 individuals. The latter group was generally no different from the single contact group but did have a tendency to be younger. This research highlights the need for a re-evaluation of service provision and associated education of police officers and relevant mental health care professionals.

  7. Measurement methods and variability assessment of the Norway spruce total leaf area: Implications for remote sensing

    NARCIS (Netherlands)

    Homolova, L.; Lukes, P.; Malenovsky, Z.; Lhotakova, Z.; Kaplan, V.; Hanus, J.

    2013-01-01

    Estimation of total leaf area (LAT) is important to express biochemical properties in plant ecology and remote sensing studies. A measurement of LAT is easy in broadleaf species, but it remains challenging in coniferous canopies. We proposed a new geometrical model to estimate Norway spruce LAT and

  8. Changes in contact area characteristics of the ankle after a cartilage biopsy at the postero-medial rim of the talar dome.

    Science.gov (United States)

    Matricali, G A; Bartels, W; Labey, L; Dereymaeker, G Ph E; Luyten, F P; Vander Sloten, J

    2009-11-01

    Study the changes in local and generalized biomechanical characteristics of the ankle joint, associated with a well defined cartilage biopsy at the postero-medial rim of the talar dome, to evaluate its safety. Ten cadaver ankles were (sub-) physiologically loaded pre- and post-biopsy; in neutral position, 10 degrees of plantar-flexion (PF) and 10 degrees of dorsi-flexion (DF). Fuji film was used as transducer. Qualitatively, the coverage of the biopsy by the tibial plafond, and changes in the shape of the footprint were analyzed. Quantitatively, the pressure profile plot, normalized-tibio-talar contact area and the centroid position of pressure were examined. Results were reported as a mean for all specimens, and as individual values for every single specimen as well. Mean results did not show significant changes, but those of some single specimens did. The majority of those changes were in PF. Some occurred in N, and besides two exceptions none occurred in DF. Two specimens did not show any change. One specimen showed an isolated quantitative change. Seven specimens showed both qualitative and quantitative changes. However, all changes were of low-magnitude and contact stresses did not show any rebound effect. Although biopsies at the postero-medial rim of the talar dome did not induce on average significant changes in quantitative contact characteristics, few specimens did show some alterations. Currently, the investigated biopsy site seems safe, but long term follow-up studies in patients are needed for confirmation.

  9. Probing into frictional contact dynamics by ultrasound and electrical simulations

    Directory of Open Access Journals (Sweden)

    Changshan Jin

    2014-12-01

    Full Text Available Friction arises in the interface of friction pair, and therefore, it is difficult to detect it. Ultrasonic means, as a NDT, is the correct alternative. This paper introduces a means of detecting dynamic contact and an interpretation of behaviors of dry friction. It has been determined that frictional surfaces have a specific property of dynamic response hardening (DRH. Dynamic response forces and oscillation arise during static–kinetic transition process. While the contact zone of sliding surfaces appears “hard” in motion, it appears “soft” at rest. Consequently, a separation of the surfaces occurs and the real area of contact is decreased as sliding velocity increases. This is the cause of F–v descent phenomenon. When the friction comes to a rest, the remaining process of DRH and micro-oscillation do not disappear instantaneously, instead they gradually return to their original static position. The contact area, therefore, is increased by rest period (F–T ascent characteristics. Based on analogies between a solid unit (η–m–k and an R-L-C circuit, the DRH is demonstrated by electrical simulations.

  10. Repertoire of free-living protozoa in contact lens solutions.

    Science.gov (United States)

    Bouchoucha, Ibtissem; Aziz, Aurore; Hoffart, Louis; Drancourt, Michel

    2016-10-29

    The repertoire of free-living protozoa in contact lens solutions is poorly known despite the fact that such protozoa may act as direct pathogens and may harbor intra-cellular pathogens. Between 2009 and 2014, the contact lens solutions collected from patients presenting at our Ophthalmology Department for clinically suspected keratitis, were cultured on non-nutrient agar examined by microscope for the presence of free-living protozoa. All protozoa were identified by 18S rRNA gene sequencing. A total of 20 of 233 (8.6 %) contact lens solution specimens collected from 16 patients were cultured. Acanthamoeba amoeba in 16 solutions (80 %) collected from 12 patients and Colpoda steini, Cercozoa sp., Protostelium sp. and a eukaryotic more closely related to Vermamoeba sp., were each isolated in one solution. Cercozoa sp., Colpoda sp., Protostelium sp. and Vermamoeba sp. are reported for the first time as contaminating contact lens solutions. The repertoire of protozoa in contact lens solutions is larger than previously known.

  11. An argon ion beam milling process for native AlOx layers enabling coherent superconducting contacts

    Science.gov (United States)

    Grünhaupt, Lukas; von Lüpke, Uwe; Gusenkova, Daria; Skacel, Sebastian T.; Maleeva, Nataliya; Schlör, Steffen; Bilmes, Alexander; Rotzinger, Hannes; Ustinov, Alexey V.; Weides, Martin; Pop, Ioan M.

    2017-08-01

    We present an argon ion beam milling process to remove the native oxide layer forming on aluminum thin films due to their exposure to atmosphere in between lithographic steps. Our cleaning process is readily integrable with conventional fabrication of Josephson junction quantum circuits. From measurements of the internal quality factors of superconducting microwave resonators with and without contacts, we place an upper bound on the residual resistance of an ion beam milled contact of 50 mΩ μm2 at a frequency of 4.5 GHz. Resonators for which only 6% of the total foot-print was exposed to the ion beam milling, in areas of low electric and high magnetic fields, showed quality factors above 106 in the single photon regime, and no degradation compared to single layer samples. We believe these results will enable the development of increasingly complex superconducting circuits for quantum information processing.

  12. High-speed railway lines. Fatigue of contact wires

    Energy Technology Data Exchange (ETDEWEB)

    Avronsart, Stephane; Kalsbeek, Guido van [SNCF, La Plaine St. Denis (France); Mai, Si Hai; Massat, Jean Pierre; Nguyen-Tajan, Thi Mac-Lan [SNCF, Paris (France)

    2013-06-15

    With more than 30 years of operation of High-Speed Lines, SNCF has a large feedback on behaviour of components. Regarding the contact wire, the only operation of maintenance consists in measuring the thickness in order to estimate the remaining lifetime which in total is around 50 years. With such a long period of operation the question was raised on fatigue phenomena. The research project launched by SNCF on this topic in 2011 includes tests on copper material characteristics, modelling of the crack initiation and propagation and detection of cracks on the contact wire. The result of this research project could lead to request for changes in EN 50149 by introducing new material characteristic parameters for contact wire related to fatigue. (orig.)

  13. Performance Analysis of Functionally Graded Coatings in Contact with Cylindrical Rollers

    Directory of Open Access Journals (Sweden)

    Reza Jahedi

    2015-01-01

    Full Text Available This work presents finite element analysis (FEA and results for rolling contact of a cylindrical roller on an elastic substrate coated by functionally graded material (FGM. The rolling process and the graded coating material property and layers arrangement are modeled using finite element codes which lead to a new methodology. This novel methodology provides a trend in determining surface contact stresses, deformations, contact zones, and energy dissipation through the contact area. Effects of stiffness ratio, friction, and exponentially variation of material property on the contact stresses and deformations are studied. Some of the results are verified with analytical solutions. The study results may be beneficial in graded coated cylindrical components analysis against rolling contact failure and wear.

  14. The Nature Contact Questionnaire: a measure of healthy workplace exposure.

    Science.gov (United States)

    Largo-Wight, Erin; Chen, W William; Dodd, Virginia; Weiler, Robert

    2011-01-01

    Understanding and promoting healthy workplaces is an important and growing area of interest in occupational health. Nature contact is a central component to the study of and promotion of healthy places. Previous findings suggest that nature contact influences health via stress appraisal process. Currently, there are no known comprehensive valid and reliable measures of nature contact, which presents obstacles to research and worksite health promotion. This study was designed to develop and test an instrument to measure nature contact at work, entitled the Nature Contact Questionnaire (NCQ), 16-item self-reported checklist to measure actual exposure. A sample of 503 (30% response rate) office staff completed the questionnaire. Office staff were sent an email with a link to the electronic survey twice, two weeks apart. Content and construct validity (KMO=0.68), internal consistency (Alpha=0.64), and test-retest reliability (r=0.85, pnature contact, which allows research to compare forms of nature contact to best inform practice and design of healthy places.

  15. Quality control related to total quality: why not to nuclear area too?

    International Nuclear Information System (INIS)

    Vasques, R.J.

    1992-01-01

    We're living in a new economical age, where quality, productivity, competence, competitiveness and costumer satisfaction are necessary. We must develop our capacity more and more, daily, for could survive and to excel in this new age. Only through Total Quality Control (TQC) is that we'll go to achieve these requirements. TQC is expanding all over the world and is already, the new universal language. Why not get the TQC's benefits to nuclear area too? We must stay within this reality. With our quality assurance systems turned to TQC, certainly we'll get best results. This is the intention of this paper: to call the nuclear professionals attention to knowledge, application and commitment to TQC's philosophy. (author)

  16. Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area.

    Science.gov (United States)

    Takemoto, Mitsuru; Fujibayashi, Shunsuke; Ota, Eigo; Otsuki, Bungo; Kimura, Hiroaki; Sakamoto, Takeshi; Kawai, Toshiyuki; Futami, Tohru; Sasaki, Kiyoyuki; Matsushita, Tomiharu; Nakamura, Takashi; Neo, Masashi; Matsuda, Shuich

    2016-06-01

    Image-based navigational patient-specific templates (PSTs) for pedicle screw (PS) placement have been described. With recent advances in three-dimensional computer-aided designs and additive manufacturing technology, various PST designs have been reported, although the template designs were not optimized. We have developed a novel PST design that reduces the contact area without sacrificing stability. It avoids susceptibility to intervening soft tissue, template geometric inaccuracy, and difficulty during template fitting. Fourteen candidate locations on the posterior aspect of the vertebra were evaluated. Among them, locations that had high reproducibility on computed tomography (CT) images and facilitated accurate PS placement were selected for the final PST design. An additive manufacturing machine (EOSINT M270) fabricated the PSTs using commercially pure titanium powder. For the clinical study, 36 scoliosis patients and 4 patients with ossification of the posterior longitudinal ligament (OPLL) were treated with thoracic PSs using our newly developed PSTs. We intraoperatively and postoperatively evaluated the accuracy of the PS hole created by the PST. Based on the segmentation reproducibility and stability analyses, we selected seven small, round contact points for our PST: bilateral superior and inferior points on the transverse process base, bilateral inferior points on the laminar, and a superior point on the spinous process. Clinically, the success rates of PS placement using this PST design were 98.6 % (414/420) for scoliosis patients and 100 % (46/46) for OPLL patients. This study provides a useful design concept for the development and introduction of patient-specific navigational templates for placing PSs.

  17. Contact characteristics of the subtalar joint after a simulated calcaneus fracture.

    Science.gov (United States)

    Sangeorzan, B J; Ananthakrishnan, D; Tencer, A F

    1995-06-01

    A simple calcaneus fracture consisting of two parts was modeled in nine fresh cadaver hindfoot specimens to assess changes in subtalar joint contact characteristics with increasing plantar depression of the posterolateral fracture component. To perform the experiment, rods were placed in the tibial and fibular shafts of each specimen, which was mounted in a frame in neutral stance. A pneumatic cylinder was used to deliver a vertical compressive load through the rods into the foot while permitting free motion of the foot in the horizontal plane. Sealed packets of pressure-sensitive film were inserted into the anterior-middle and posterior facets of the talocalcaneal articulation, and a 700-N load was applied. After testing of the intact foot, a primary fracture line was created using a microoscillating saw. The osteotomized posterolateral component was anatomically reduced and fixed, the film inserted, and the load reapplied. The test was repeated after the posterolateral fragment was displaced 2, 5, and 10 mm in a plantar direction. The resulting pressure prints were scanned along with pressure/color density calibration strips using a flat-bed scanner, and an image analysis system was used to determine contact areas within specified pressure intervals. The contact area (> 0.5 MPa) of the posterior facet was significantly decreased with 2, 5, and 10 mm displacements of the posterolateral calcaneus fracture component. The ratio of high-pressure area (< 5.0 MPa) to contact area in the posterior facet was significantly increased only with displacements of 5 and 10 mm. There were no significant changes in any contact parameters in the anterior-middle facet.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Cost-of-illness of patients with contact dermatitis in Denmark

    DEFF Research Database (Denmark)

    Saetterstrøm, Bjørn; Olsen, Jens; Johansen, Jeanne Duus

    2014-01-01

    BACKGROUND: Contact dermatitis is a frequent occupational and non-occupational skin disease. OBJECTIVES: To investigate the effects of contact dermatitis on labour market affiliation and societal costs in terms of healthcare costs and production loss. METHODS: A total of 21 441 patients patch...... tested either in hospital departments or at dermatological clinics in the period 2004-2009 were included in the study. The analyses were stratified by children (age 0-15 years), occupational contact dermatitis (age 16-65 years), and non-occupational dermatitis (age ≥ 16 years). Controls were selected...... prior to patch testing (1 year for children) and the year after patch testing were €959 for children, €724 for occupational contact dermatitis, and €1794 for non-occupational dermatitis. Productivity costs for the same period were €10 722 for occupational contact dermatitis and €3074 for non...

  19. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  20. Corner S-N-D contacts in magnetic field

    CERN Document Server

    Barash, Yu S

    2001-01-01

    The dependence of the critical current of the S-N-D angular contacts with high transparency on the applied magnetic field field for various orientations of the superconductor with the d-coupling is established. It is shown that availability of the plateau in the certain interval of the magnetic field values is characteristic feature of critical current interference dependences in the angular contacts with high transparency on the current by sufficiently low temperatures. The plateau is mostly expressed in the characteristics of the S-N-D angular contacts with the orientations (100) and (010) the boundary in the superconductor with the d-coupling. With the temperature growth the area with the plateau gets distorted and disappears

  1. Bimetallic nanoparticles for surface modification and lubrication of MEMS switch contacts

    Energy Technology Data Exchange (ETDEWEB)

    Patton, Steven T; Hu Jianjun [University of Dayton Research Institute, Dayton, OH 45469-0168 (United States); Slocik, Joseph M; Campbell, Angela; Naik, Rajesh R; Voevodin, Andrey A [Materials and Manufacturing Directorate, Air Force Research Laboratory, Wright-Patterson Air Force Base, OH 45433-7750 (United States)], E-mail: steve.patton@wpafb.af.mil, E-mail: rajesh.naik@wpafb.af.mil

    2008-10-08

    Reliability continues to be a critical issue in microelectromechanical systems (MEMS) switches. Failure mechanisms include high contact resistance (R), high adhesion, melting/shorting, and contact erosion. Little previous work has addressed the lubrication of MEMS switches. In this study, bimetallic nanoparticles (NPs) are synthesized using a biotemplated approach and deposited on Au MEMS switch contacts as a nanoparticle-based lubricant. Bimetallic nanoparticles are comprised of a metallic core ({approx}10 nm diameter gold nanoparticle) with smaller metallic nanoparticles ({approx}2-3 nm diameter Pd nanoparticles) populating the core surface. Adhesion and resistance (R) were measured during hot switching experiments at low (10 {mu}A) and high (1 mA) current. The Au/Pd NP coated contacts led to reduced adhesion as compared to pure Au contacts with a compromise of slightly higher R. For switches held in the closed position at low current, R gradually decreased over tens of seconds due to increased van der Waals force and growth of the real area of contact with temporal effects being dominant over load effects. Contact behavior transitioned from 'Pd-like' to 'Au-like' during low current cycling experiments. Melting at high current resulted in rapid formation of large real contact area, low and stable R, and minimal effect of load on R. Durability at high current was excellent with no failure through 10{sup 6} hot switching cycles. Improvement at high current is due to controlled nanoscale surface roughness that spreads current through multiple nanocontacts, which restricts the size of melting regions and causes termination of nanowire growth (prevents shorting) during contact opening. Based on these results, bimetallic NPs show excellent potential as surface modifiers/lubricants for MEMS switch contacts.

  2. Active Surveillance of Hansen's Disease (Leprosy): Importance for Case Finding among Extra-domiciliary Contacts

    Science.gov (United States)

    Moura, Maria L. N.; Dupnik, Kathryn M.; Sampaio, Gabriel A. A.; Nóbrega, Priscilla F. C.; Jeronimo, Ana K.; do Nascimento-Filho, Jose M.; Miranda Dantas, Roberta L.; Queiroz, Jose W.; Barbosa, James D.; Dias, Gutemberg; Jeronimo, Selma M. B.; Souza, Marcia C. F.; Nobre, Maurício L.

    2013-01-01

    Hansen's disease (leprosy) remains an important health problem in Brazil, where 34,894 new cases were diagnosed in 2010, corresponding to 15.3% of the world's new cases detected in that year. The purpose of this study was to use home visits as a tool for surveillance of Hansen's disease in a hyperendemic area in Brazil. A total of 258 residences were visited with 719 individuals examined. Of these, 82 individuals had had a previous history of Hansen's disease, 209 were their household contacts and 428 lived in neighboring residences. Fifteen new Hansen's disease cases were confirmed, yielding a detection rate of 2.0% of people examined. There was no difference in the detection rate between household and neighbor contacts (p = 0.615). The two groups had the same background in relation to education (p = 0.510), household income (p = 0.582), and the number of people living in the residence (p = 0.188). Spatial analysis showed clustering of newly diagnosed cases and association with residential coordinates of previously diagnosed multibacillary cases. Active case finding is an important tool for Hansen's disease control in hyperendemic areas, enabling earlier diagnosis, treatment, decrease in disability from Hansen's disease and potentially less spread of Mycobacterium leprae. PMID:23516645

  3. Rough viscoelastic sliding contact: Theory and experiments

    Science.gov (United States)

    Carbone, G.; Putignano, C.

    2014-03-01

    In this paper, we show how the numerical theory introduced by the authors [Carbone and Putignano, J. Mech. Phys. Solids 61, 1822 (2013), 10.1016/j.jmps.2013.03.005] can be effectively employed to study the contact between viscoelastic rough solids. The huge numerical complexity is successfully faced up by employing the adaptive nonuniform mesh developed by the authors in Putignano et al. [J. Mech. Phys. Solids 60, 973 (2012), 10.1016/j.jmps.2012.01.006]. Results mark the importance of accounting for viscoelastic effects to correctly simulate the sliding rough contact. In detail, attention is, first, paid to evaluate the viscoelastic dissipation, i.e., the viscoelastic friction. Fixed the sliding speed and the normal load, friction is completely determined. Furthermore, since the methodology employed in the work allows to study contact between real materials, a comparison between experimental outcomes and numerical prediction in terms of viscoelastic friction is shown. The good agreement seems to validate—at least partially—the presented methodology. Finally, it is shown that viscoelasticity entails not only the dissipative effects previously outlined, but is also strictly related to the anisotropy of the contact solution. Indeed, a marked anisotropy is present in the contact region, which results stretched in the direction perpendicular to the sliding speed. In the paper, the anisotropy of the deformed surface and of the contact area is investigated and quantified.

  4. Prevalence of Contact Allergy to p-Phenylenediamine in the European General Population

    NARCIS (Netherlands)

    Diepgen, Thomas L.; Naldi, Luigi; Bruze, Magnus; Cazzaniga, Simone; Schuttelaar, Marie-Louise; Elsner, Peter; Goncalo, Margarida; Ofenloch, Robert; Svensson, Ake

    Population-based studies on contact allergy to p-phenylenediamine (PPD) are scarce. A cross-sectional study was performed to assess the prevalence of contact allergy to PPD and its risk factors in the general population of 5 European countries. A total of 10,425 subjects were interviewed, and a

  5. Racial Prejudice, Interracial Contact, and Personality Variables.

    Science.gov (United States)

    Moore, J. William; And Others

    1984-01-01

    This study examined the relationship of childrens' racial prejudice to child's race, interracial contact, grade, sex, intelligence, locus of control, anxiety, and self-concept. Five facets of racial prejudice were examined: a total index of racial prejudice, dating and marriage, school, social relationships, and racial interactions in restaurants.…

  6. Total mercury, methylmercury and selenium in mercury polluted areas in the province Guizhou, China.

    Science.gov (United States)

    Horvat, Milena; Nolde, Natasa; Fajon, Vesna; Jereb, Vesna; Logar, Martina; Lojen, Sonja; Jacimovic, Radojko; Falnoga, Ingrid; Liya, Qu; Faganeli, Jadran; Drobne, Damjana

    2003-03-20

    The province of Guizhou in Southwestern China is currently one of the world's most important mercury production areas. Emissions of mercury from the province to the global atmosphere have been estimated to be approximately 12% of the world total anthropogenic emissions. The main objective of this study was to assess the level of contamination with Hg in two geographical areas of Guizhou province. Mercury pollution in the areas concerned originates from mercury mining and ore processing in the area of Wanshan, while in the area of Quingzhen mercury pollution originates from the chemical industry discharging Hg through wastewaters and emissions to the atmosphere due to coal burning for electricity production. The results of this study confirmed high contamination with Hg in soil, sediments and rice in the Hg mining area in Wanshan. High levels of Hg in soil and rice were also found in the vicinity of the chemical plant in Quingzhen. The concentrations of Hg decreased with distance from the main sources of pollution considerably. The general conclusion is that Hg contamination in Wanshan is geographically more widespread, due to deposition and scavenging of Hg from contaminated air and deposition on land. In Quingzhen Hg contamination of soil is very high close to the chemical plant but the levels reach background concentrations at a distance of several km. Even though the major source of Hg in both areas is inorganic Hg, it was observed that active transformation of inorganic Hg to organic Hg species (MeHg) takes place in water, sediments and soils. The concentration of Hg in rice grains can reach up to 569 microg/kg of total Hg of which 145 microg/kg was in MeHg form. The percentage of Hg as MeHg varied from 5 to 83%. The concentrations of selenium can reach up to 16 mg/kg in soil and up to 1 mg/g in rice. A correlation exists between the concentration of Se in soil and rice, indicating that a portion of Se is bioavailable to plants. No correlation between Hg and Se

  7. Prioritized Contact Transport Stream

    Science.gov (United States)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  8. In vitro power profiles of daily disposable contact lenses.

    Science.gov (United States)

    Belda-Salmerón, Lurdes; Madrid-Costa, David; Ferrer-Blasco, Teresa; García-Lázaro, Santiago; Montés-Micó, Robert

    2013-10-01

    To evaluate and compare the distribution of refractive power within the optic zone of different soft contact lenses and to investigate the effect of lens decentration on the power profiles. The Nimo TR1504 instrument was used to measure the optical power across different aperture diameters (from 1.5mm to 5.5mm in steps of 0.5mm) of four daily disposable contact lenses: DAILIES TOTAL1, Proclear 1-Day, SofLens daily disposable and 1-DAY ACUVUE MOIST. Measurements were performed using a wet cell. Power data were evaluated when contact lenses were in its centered position and after inducing different amounts of lens decentration (from 0.2mm to 1.0mm in steps of 0.2mm). All contact lenses showed an increase - more negative - in lens power with distance from the lens center. The amount of change varied depending on the lens. It was about 10% of lens power for DAILIES TOTAL1 (-0.29diopters (D)), SofLens daily disposable (-0.36D), and Proclear 1-Day (-0.32D) whereas 1-DAY ACUVUE MOIST showed a percentage variation of 3.3% (-0.10D). After inducing a lens decentration up to 1mm, the power curves were shifted in the negative direction. However, the change obtained in lens power compared with well-centered position was always lower than a quarter of diopter both for all the lenses and aperture diameters. Our results showed a variation of the refractive power from the lens center, becoming more negative toward the periphery, with a negligible effect of the decentration for all disposable contact lenses studied. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  9. American Contact Dermatitis Society Contact Allergy Management Program: An Epidemiologic Tool to Determine Relative Prevalence of Contact Allergens.

    Science.gov (United States)

    Scheman, Andrew; Severson, David

    2016-01-01

    Data on the prevalence of contact allergy in North America are currently reported by groups of academic contact allergy specialists at select academic centers. Sampling of data from numerous centers across North America, including practices performing more limited patch testing, would provide a broader perspective of contact allergen prevalence in North America. The American Contact Dermatitis Society Contact Allergy Management Program is an ideal tool for collection of epidemiologic data regarding contact allergy prevalence in North America. The aim of the study was to identify the relative prevalence of contact allergy to common contact allergens in North America. Mapping of Contact Allergy Management Program (CAMP) data was performed to allow analysis of how frequently searches were performed for various contact allergens. The number of searches performed for specific allergens provides a measure of the relative prevalence of contact allergy to these allergens. The top 35 allergens for the period from November 18, 2012 to November 18, 2013 are reported. Although these data are useful, specific recommendations for minor alterations to CAMP are discussed, which will allow future CAMP data to be stratified and more powerful. With minor modifications, CAMP can provide a quantum leap in the reporting of contact allergy epidemiologic data in North America.

  10. Cost-effectiveness of a chemoprophylactic intervention with single dose rifampicin in contacts of new leprosy patients.

    Directory of Open Access Journals (Sweden)

    Willemijn J Idema

    Full Text Available BACKGROUND: With 249,007 new leprosy patients detected globally in 2008, it remains necessary to develop new and effective interventions to interrupt the transmission of M. leprae. We assessed the economic benefits of single dose rifampicin (SDR for contacts as chemoprophylactic intervention in the control of leprosy. METHODS: We conducted a single centre, double blind, cluster randomised, placebo controlled trial in northwest Bangladesh between 2002 and 2007, including 21,711 close contacts of 1,037 patients with newly diagnosed leprosy. We gave a single dose of rifampicin or placebo to close contacts, with follow-up for four years. The main outcome measure was the development of clinical leprosy. We assessed the cost effectiveness by calculating the incremental cost effectiveness ratio (ICER between the standard multidrug therapy (MDT program with the additional chemoprophylaxis intervention versus the standard MDT program only. The ICER was expressed in US dollars per prevented leprosy case. FINDINGS: Chemoprophylaxis with SDR for preventing leprosy among contacts of leprosy patients is cost-effective at all contact levels and thereby a cost-effective prevention strategy. In total, $6,009 incremental cost was invested and 38 incremental leprosy cases were prevented, resulting in an ICER of $158 per one additional prevented leprosy case. It was the most cost-effective in neighbours of neighbours and social contacts (ICER $214, slightly less cost-effective in next door neighbours (ICER $497 and least cost-effective among household contacts (ICER $856. CONCLUSION: Chemoprophylaxis with single dose rifampicin given to contacts of newly diagnosed leprosy patients is a cost-effective intervention strategy. Implementation studies are necessary to establish whether this intervention is acceptable and feasible in other leprosy endemic areas of the world.

  11. Total nitrogen and total phosphorus removal from brackish aquaculture wastewater using effective microorganism

    Science.gov (United States)

    Mohamad, K. A.; Mohd, S. Y.; Sarah, R. S.; Mohd, H. Z.; Rasyidah, A.

    2017-09-01

    Aquaculture is one of dominant food based industry in the world with 8.3% annual growth rate and its development had led to adverse effect on the environment. High nutrient production in form of nitrogenous compound and phosphorus contributed to environmental deterioration such as eutrophication and toxicity to the industry. Usage of Effective Microorganism (EM), one of the biological approaches to remove Total Nitrogen (TN) and Total Phosphorus (TP) in aquaculture pond was proposed. Samples were obtained from the Sea Bass intensive brackish aquaculture wastewater (AW) from fish farm at Juru, Penang and the parameters used to measure the removal of nitrogenous compounds include, pH, EM dosage, shaking, contact time and optimum variable conditions. From the study, for effective contact time, day 6 is the optimum contact time for both TN and TP with 99.74% and 62.78% removal respectively while in terms of optimum pH, the highest TN removal was at pH 7 with 66.89 %. The optimum dosage of EM is 1.5 ml with ratio 1:166 for 81.5 % TN removal was also found appropriate during the experiment. At varied optimum conditions of EM, the removal efficiency of TN and TP were 81.53% and 38.94% respectively while the removal mechanism of TN was highly dependent on the decomposition rate of specific bacteria such as Nitrobacter bacteria, Yeast and Bacillus Subtilis sp. The study has established the efficacy of EM's ability to treat excessive nutrient of TN and TP from AW.

  12. Identification of contact and respiratory sensitizers using flow cytometry

    International Nuclear Information System (INIS)

    Goutet, Michele; Pepin, Elsa; Langonne, Isabelle; Huguet, Nelly; Ban, Masarin

    2005-01-01

    Identification of the chemicals responsible for respiratory and contact allergies in the industrial area is an important occupational safety issue. This study was conducted in mice to determine whether flow cytometry is an appropriate method to analyze and differentiate the specific immune responses to the respiratory sensitizer trimellitic anhydride (TMA) and to the contact sensitizer dinitrochlorobenzene (DNCB) used at concentrations with comparable immunogenic potential. Mice were exposed twice on the flanks (days 0, 5) to 10% TMA or 1% DNCB and challenged three times on the ears (days 10, 11, 12) with 2.5% TMA or 0.25% DNCB. Flow cytometry analyses were conducted on draining lymph node cells harvested on days 13 and 18. Comparing TMA and DNCB immune responses on day 13, we found obvious differences that persisted for most of them on day 18. An increased proportion of IgE+ cells correlated to total serum IgE level and an enhancement of MHC II molecule expression were observed in the lymph node B lymphocytes from TMA-treated mice. The percentage of IL-4-producing CD4+ lymphocytes and the IL-4 receptor expression were clearly higher following TMA exposure. In contrast, higher proportions of IL-2-producing cells were detected in CD4+ and CD8+ cells from DNCB-treated mice. Both chemicals induced a significant increase in the percentage of IFN-γ-producing cells among CD8+ lymphocytes but to a greater proportion following TMA treatment. In conclusion, this study encourages the use of flow cytometry to discriminate between contact and respiratory sensitizers by identifying divergent expression of immune response parameters

  13. Allergic Contact Dermatitis Is Associated with Significant Oxidative Stress

    Directory of Open Access Journals (Sweden)

    S. Kaur

    2014-01-01

    Full Text Available Background. Research has confirmed the involvement of oxidative stress (OxS in allergic contact dermatitis whilst other inflammation-related biomarkers have been less studied. Objective. To evaluate systemic levels of selected inflammatory markers, OxS indices and adipokines as well as their associations in allergic contact dermatitis. Methods. In 40 patients, interleukin- (IL- 6, monocyte chemoattractant protein (MCP-1, and IL-10 levels were measured in sera with the Evidence Investigator Cytokine & Growth factors High-Sensitivity Array, total peroxide concentration (TPX and total antioxidant capacity (TAC by means of spectrophotometry, and the plasma concentrations of adiponectin and leptin by the quantitative sandwich enzyme immunoassay technique. Results. TNF-α level (P < 0.01 and TPX (P < 0.0001 were increased whilst IL-10 (P < 0.05 and TAC (P < 0.0001 were decreased in the patients as compared to controls. Correlation and multiple linear regression analysis identified both, TPX and TAC (inversely, as possible independent markers for evaluating allergic contact dermatitis. Adiponectin level in patients was increased (P < 0.0001, but neither adiponectin nor leptin correlated significantly with the biomarkers of inflammation or OxS. Conclusion. OxS parameters, especially TPX and OSI, reflect the degree of systemic inflammation associated with allergic contact dermatitis in the best way. The relation between OxS and adiponectin level warrants further studies.

  14. Holding the baby: early mother-infant contact after childbirth and outcomes.

    Science.gov (United States)

    Redshaw, Maggie; Hennegan, Julie; Kruske, Sue

    2014-05-01

    to describe the timing, type and duration of initial infant contact and associated demographic and clinical factors in addition to investigating the impact of early contact on breastfeeding and maternal health and well being after birth. data from a recent population survey of women birthing in Queensland, Australia were used to describe the nature of the first hold and associated demographic characteristics. Initial comparisons, with subsequent adjustment for type of birthing facility and mode of childbirth, were used to assess associations between timing, type and duration of initial contact and outcomes. Further analyses were conducted to investigate a dose-response relationship between duration of first contact and outcomes. women who had an unassisted vaginal birth held their infant sooner, and for longer than women who had an assisted vaginal birth or caesarean and were more satisfied with their early contact. Multivariate models showed a number of demographic and clinical interventions contributing to timing, duration and type of first contact with type of birthing facility (public/private), area of residence, and assisted birth as prominent factors. For women who had a vaginal birth; early, skin-to-skin, and longer duration of initial contact were associated with high rates of breastfeeding initiation and breastfeeding at discharge, but not breastfeeding at 13 weeks. Some aspects of early contact were associated with improved maternal well being. However, these associations were not found for women who had a caesarean birth. With longer durations of first contact, a dose-response effect was found for breastfeeding. results of the study provide a description of current practice in Queensland, Australia and factors impacting on early contact. For vaginal births, findings add to the evidence in support of early skin-to-skin contact for an extended period. It is suggested that all research in this area should consider the effects of early contact separately for

  15. Effects of counteracting external valgus moment on lateral tibial cartilage contact conditions and tibial rotation.

    Science.gov (United States)

    Shriram, Duraisamy; Parween, Rizuwana; Lee, Yee Han Dave; Subburaj, Karupppasamy

    2017-07-01

    Knee osteoarthritis that prevalently occurs at the medial compartment is a progressive chronic disorder affecting the articular cartilage of the knee joint, and lead to loss of joint functionality. Valgus braces have been used as a treatment procedure to unload the medial compartment for patients with medial osteoarthritis. Valgus braces through the application of counteracting external valgus moment shift the load from medial compartment towards the lateral compartment. Previous biomechanical studies focused only on the changes in varus moments before and after wearing the brace. The objective of this study was to investigate the influence of opposing external valgus moment applied by knee braces on the lateral tibial cartilage contact conditions using a 3D finite element model of the knee joint. Finite element simulations were performed on the knee joint model without and with the application of opposing valgus moment to mimic the unbraced and braced conditions. Lateral tibial cartilage contact pressures and contact area, and tibial rotation (varus-valgus and internal-external) were estimated for the complete walking gait cycle. The opposing valgus moment increased the maximum contact pressure and contact area on the lateral tibial cartilage compared to the normal gait moment. A peak contact pressure of 8.2 MPa and maximum cartilage loaded area of 28% (loaded cartilage nodes) on the lateral cartilage with the application of external valgus moment were induced at 50% of the gait cycle. The results show that the use of opposing valgus moment may significantly increase the maximum contact pressures and contact area on the lateral tibial cartilage and increases the risk of articular cartilage damage on the lateral compartment.

  16. Thermodynamic analysis of effects of contact angle on interfacial interactions and its implications for membrane fouling control.

    Science.gov (United States)

    Chen, Jianrong; Shen, Liguo; Zhang, Meijia; Hong, Huachang; He, Yiming; Liao, Bao-Qiang; Lin, Hongjun

    2016-02-01

    Concept of hydrophobicity always fails to accurately assess the interfacial interaction and membrane fouling, which calls for reliable parameters for this purpose. In this study, effects of contact angle on interfacial interactions related to membrane fouling were investigated based on thermodynamic analysis. It was found that, total interaction energy between sludge foulants and membrane monotonically decreases and increases with water and glycerol contact angle, respectively, indicating that these two parameters can be reliable indicators predicting total interaction energy and membrane fouling. Membrane roughness decreases interaction strength for over 20 times, and effects of membrane roughness on membrane fouling should consider water and glycerol contact angle on membrane. It was revealed existence of a critical water and glycerol contact angle for a given membrane bioreactor. Meanwhile, diiodomethane contact angle has minor effect on the total interaction, and cannot be regarded as an effective indicator assessing interfacial interactions and membrane fouling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Language Contact.

    Science.gov (United States)

    Nelde, Peter Hans

    1995-01-01

    Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)

  18. Contact area affects frequency-dependent responses to vibration in the peripheral vascular and sensorineural systems.

    Science.gov (United States)

    Krajnak, Kristine; Miller, G R; Waugh, Stacey

    2018-01-01

    Repetitive exposure to hand-transmitted vibration is associated with development of peripheral vascular and sensorineural dysfunctions. These disorders and symptoms associated with it are referred to as hand-arm vibration syndrome (HAVS). Although the symptoms of the disorder have been well characterized, the etiology and contribution of various exposure factors to development of the dysfunctions are not well understood. Previous studies performed using a rat-tail model of vibration demonstrated that vascular and peripheral nervous system adverse effects of vibration are frequency-dependent, with vibration frequencies at or near the resonant frequency producing the most severe injury. However, in these investigations, the amplitude of the exposed tissue was greater than amplitude typically noted in human fingers. To determine how contact with vibrating source and amplitude of the biodynamic response of the tissue affects the risk of injury occurring, this study compared the influence of frequency using different levels of restraint to assess how maintaining contact of the tail with vibrating source affects the transmission of vibration. Data demonstrated that for the most part, increasing the contact of the tail with the platform by restraining it with additional straps resulted in an enhancement in transmission of vibration signal and elevation in factors associated with vascular and peripheral nerve injury. In addition, there were also frequency-dependent effects, with exposure at 250 Hz generating greater effects than vibration at 62.5 Hz. These observations are consistent with studies in humans demonstrating that greater contact and exposure to frequencies near the resonant frequency pose the highest risk for generating peripheral vascular and sensorineural dysfunction.

  19. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

    Science.gov (United States)

    Tan, Daniel W; Schiefer, Matthew A; Keith, Michael W; Anderson, J Robert; Tyler, Dustin J

    2015-04-01

    Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. Multi-contact cuff electrodes were implanted in the median, ulnar, and radial nerves of the upper-limb. Nerve stimulation produced a selective sensory response on 19 of 20 contacts and 16 of 16 contacts in subjects 1 and 2, respectively. Stimulation elicited multiple, distinct percept areas on the phantom and residual limb. Consistent threshold, impedance, and percept areas have demonstrated that the neural interface is stable for the duration of this on-going, chronic study. We have achieved selective nerve response from multi-contact cuff electrodes by demonstrating characteristic percept areas and thresholds for each contact. Selective sensory response remains consistent in two upper-limb amputees for 1 and 2 years, the longest multi-contact sensory feedback system to date. Our approach demonstrates selectivity and stability can be achieved through an extraneural interface, which can provide sensory feedback to amputees.

  20. Contact mechanics for layered materials with randomly rough surfaces.

    Science.gov (United States)

    Persson, B N J

    2012-03-07

    The contact mechanics model of Persson is applied to layered materials. We calculate the M function, which relates the surface stress to the surface displacement, for a layered material, where the top layer (thickness d) has different elastic properties than the semi-infinite solid below. Numerical results for the contact area as a function of the magnification are presented for several cases. As an application, we calculate the fluid leak rate for laminated rubber seals.

  1. Contact of a spherical probe with a stretched rubber substrate

    Science.gov (United States)

    Frétigny, Christian; Chateauminois, Antoine

    2017-07-01

    We report on a theoretical and experimental investigation of the normal contact of stretched neo-Hookean substrates with rigid spherical probes. Starting from a published formulation of surface Green's function for incremental displacements on a prestretched, neo-Hookean, substrate [J. Mech. Phys. Solids 56, 2957 (2008), 10.1016/j.jmps.2008.07.002], a model is derived for both adhesive and nonadhesive contacts. The shape of the elliptical contact area together with the contact load and the contact stiffness are predicted as a function of the in-plane stretch ratios λx and λy of the substrate. The validity of this model is assessed by contact experiments carried out using an uniaxally stretched silicone rubber. For stretch ratio below about 1.25, a good agreement is observed between theory and experiments. Above this threshold, some deviations from the theoretical predictions are induced as a result of the departure of the mechanical response of the silicone rubber from the neo-Hokeean description embedded in the model.

  2. Thermal effect on the thermomechanical behavior of contacts in a Traveling Wave Tube

    Directory of Open Access Journals (Sweden)

    Chbiki Mounir

    2016-01-01

    Full Text Available A new elasto-plastic study of the contact between the helix and the rods of the delay line of Traveling Waves Tubes (TWT was realized. Our study is focused on the analysis of the hot lines shrinking phenomenon. In the studied case, unlike brazed configuration, the contact areas are not perfect, resulting in a diminution of the heat transfer process. In order to maximize the contact area and to homogenize the contact pressure, a soft thermal conductive material is coated on the helix: copper was chosen for this study. In the present work, an analytical model is used to identify the properties of the copper coating at a given temperature. We focused on the mechanical properties in order to improve the assembly process with a better numerical study. Experimental method have been made to validate the proposed model. The first comparison results seem to indicate that the model represents the reality with a good agreement. It is very clearly shown that the temperature decreases the mechanical properties. (Young’s modulus, yield strength, tensile strength…. And the thickness of the coating increases the contact area. This last point is less important at room temperature (6% of increase than at 140°C (22%.

  3. Comparison of mechanical properties for several electrical spring contact alloys

    International Nuclear Information System (INIS)

    Nordstrom, T.V.

    1976-06-01

    Work was conducted to determine whether beryllium-nickel alloy 440 had mechanical properties which made it suitable as a substitute for the presently used precious metal contact alloys Paliney 7 and Neyoro G, in certain electrical contact applications. Possible areas of applicability for the alloy were where extremely low contact resistance was not necessary or in components encountering elevated temperatures above those presently seen in weapons applications. Evaluation of the alloy involved three major experimental areas: 1) measurement of the room temperature microplastic (epsilon approximately 10 -6 ) and macroplastic (epsilon approximately 10 -3 ) behavior of alloy 440 in various age hardening conditions, 2) determination of applied stress effects on stress relaxation or contact force loss and 3) measurement of elevated temperature mechanical properties and stress relaxation behavior. Similar measurements were also made on Neyoro G and Paliney 7 for comparison. The primary results of the study show that beryllium-nickel alloy 440 is from a mechanical properties standpoint, equal or superior to the presently used Paliney 7 and Neyoro G for normal Sandia requirements. For elevated temperature applications, alloy 440 has clearly superior mechanical properties

  4. Unilateral contact problems variational methods and existence theorems

    CERN Document Server

    Eck, Christof; Krbec, Miroslav

    2005-01-01

    The mathematical analysis of contact problems, with or without friction, is an area where progress depends heavily on the integration of pure and applied mathematics. This book presents the state of the art in the mathematical analysis of unilateral contact problems with friction, along with a major part of the analysis of dynamic contact problems without friction. Much of this monograph emerged from the authors'' research activities over the past 10 years and deals with an approach proven fruitful in many situations. Starting from thin estimates of possible solutions, this approach is based on an approximation of the problem and the proof of a moderate partial regularity of the solution to the approximate problem. This in turn makes use of the shift (or translation) technique - an important yet often overlooked tool for contact problems and other nonlinear problems with limited regularity. The authors pay careful attention to quantification and precise results to get optimal bounds in sufficient conditions f...

  5. The CAD-score web server: contact area-based comparison of structures and interfaces of proteins, nucleic acids and their complexes.

    Science.gov (United States)

    Olechnovič, Kliment; Venclovas, Ceslovas

    2014-07-01

    The Contact Area Difference score (CAD-score) web server provides a universal framework to compute and analyze discrepancies between different 3D structures of the same biological macromolecule or complex. The server accepts both single-subunit and multi-subunit structures and can handle all the major types of macromolecules (proteins, RNA, DNA and their complexes). It can perform numerical comparison of both structures and interfaces. In addition to entire structures and interfaces, the server can assess user-defined subsets. The CAD-score server performs both global and local numerical evaluations of structural differences between structures or interfaces. The results can be explored interactively using sortable tables of global scores, profiles of local errors, superimposed contact maps and 3D structure visualization. The web server could be used for tasks such as comparison of models with the native (reference) structure, comparison of X-ray structures of the same macromolecule obtained in different states (e.g. with and without a bound ligand), analysis of nuclear magnetic resonance (NMR) structural ensemble or structures obtained in the course of molecular dynamics simulation. The web server is freely accessible at: http://www.ibt.lt/bioinformatics/cad-score. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  6. Contact angle hysteresis on superhydrophobic stripes.

    Science.gov (United States)

    Dubov, Alexander L; Mourran, Ahmed; Möller, Martin; Vinogradova, Olga I

    2014-08-21

    We study experimentally and discuss quantitatively the contact angle hysteresis on striped superhydrophobic surfaces as a function of a solid fraction, ϕS. It is shown that the receding regime is determined by a longitudinal sliding motion of the deformed contact line. Despite an anisotropy of the texture the receding contact angle remains isotropic, i.e., is practically the same in the longitudinal and transverse directions. The cosine of the receding angle grows nonlinearly with ϕS. To interpret this we develop a theoretical model, which shows that the value of the receding angle depends both on weak defects at smooth solid areas and on the strong defects due to the elastic energy of the deformed contact line, which scales as ϕS(2)lnϕS. The advancing contact angle was found to be anisotropic, except in a dilute regime, and its value is shown to be determined by the rolling motion of the drop. The cosine of the longitudinal advancing angle depends linearly on ϕS, but a satisfactory fit to the data can only be provided if we generalize the Cassie equation to account for weak defects. The cosine of the transverse advancing angle is much smaller and is maximized at ϕS ≃ 0.5. An explanation of its value can be obtained if we invoke an additional energy due to strong defects in this direction, which is shown to be caused by the adhesion of the drop on solid sectors and is proportional to ϕS(2). Finally, the contact angle hysteresis is found to be quite large and generally anisotropic, but it becomes isotropic when ϕS ≤ 0.2.

  7. Association of urogenital symptoms with history of water contact in young women in areas endemic for S. haematobium

    DEFF Research Database (Denmark)

    Galappaththi-Arachchige, Hashini Nilushika; Hegertun, Ingrid Elise Amlie; Holmen, Sigve

    2016-01-01

    schistosomiasis. In a cross-sectional study in rural South Africa, 883 sexually active women aged 16–22 years were included. Questions were asked about urogenital symptoms and water contact history. Urine samples were tested for S. haematobium ova. A score based on self-reported water contact was calculated......Female genital schistosomiasis is a neglected tropical disease caused by Schistosoma haematobium. Infected females may suffer from symptoms mimicking sexually transmitted infections. We explored if self-reported history of unsafe water contact could be used as a simple predictor of genital...... and the association with symptoms was explored while adjusting for other genital infections using multivariable logistic regression analyses. S. haematobium ova were detected in the urine of 30.5% of subjects. Having ova in the urine was associated with the water contact score (p

  8. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  9. Tourism potential value assessment model for rural-mountain and boundary contact areas. Case study: Cluj County, the district of Ciceu and the balneal area of Bacău County (Romania

    Directory of Open Access Journals (Sweden)

    Bianca Sorina RĂCĂŞAN

    2016-11-01

    Full Text Available This paper aimed to develop a specific assessment method focused on the tourism potential of the rural-mountain and boundary contact areas. Once elaborated, the model was employed within three appropriate territories of Cluj, Bistrița and Bacău counties (Romania, who’s investigated administrative units, were repeatedly ranked into hierarchical order according to the different tourist categories, invested with numerical values. In order to reach its goals, several objectives were assigned, from awarding the components of the primary and secondary tourism supply certain scores, proposing scales and calculating values, to comparing the results and identifying best rated tourism potential categories, units and areas. With respect to the research methodology, the most commonly used methods dealt with observation, analysis and synthesis along with comparison, cartographical, statistical and mathematical techniques. Therefore, main results regarded both proposal and testing the evaluation model, highlighting values and ranging territorial units in concordance with the tourist attractiveness power.

  10. Frictionless contact of a rigid punch indenting a transversely isotropic elastic layer

    Directory of Open Access Journals (Sweden)

    Rajesh Patra

    2016-03-01

    Full Text Available This article is concerned with the study of frictionless contact between a rigid punch and a transversely isotropic elastic layer. The rigid punch is assumed to be axially symmetric and is being pressed towards the layer by an applied concentrated load. The layer is resting on a rigid base and is assumed to be ufficiently thick in comparison with the amount of indentation by the rigid punch. The relationship between the applied load $P$ and the contact area is obtained by solving the mathematically formulated problem through use of Hankel transform of different order. Effect of indentation on the distribution of normal stress at the surface as well as the relationship between the applied load and the area of contact have been shown graphically.

  11. Increased perirenal fat area is not associated with adverse outcomes after laparoscopic total mesorectal excision for rectal cancer

    DEFF Research Database (Denmark)

    Levic, Katarina; Bulut, Orhan; Schødt, Mette

    2017-01-01

    Introduction Intraabdominal visceral obesity may increase technical challenges during laparoscopic rectal resection and hypothetically therefore increase the risk of perioperative complications. The aim of this study was to analyze intraabdominal obesity by means of perirenal fat against risk...... of adverse outcomes in patients undergoing laparoscopic rectal cancer surgery. Methods This study was a single-institution retrospective analysis of consecutive patients undergoing laparoscopic total mesorectal surgery for rectal cancer between January 2009 and January 2013. Abdominal CT scans...... with intravenous contrast were assessed in a blinded manner to estimate the perirenal fat area (cm2). Result A total of 195 patients were included (median age 70 years (range 27–87), 58 women and 137 men) for analysis. There was a moderate correlation between BMI and perirenal fat area (r = 0.499, p = 0...

  12. Corrosion failure analysis of hearing aid battery-spring contacts

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Ambat, Rajan

    2017-01-01

    the susceptibility of these systems to galvanic corrosion. In this study, traditional behind the ear (BTE) hearing aid systems, which failed during service were analysed. Failure analysis was performed on the dome type battery-spring contact systems. The morphology of the contact areas was observed using scanning......Reliability of low power electrical contacts such as those in hearing aid battery-spring systems is a very critical aspect for the overall performance of the device. These systems are exposed to certain harsh environments like high humidity and elevated temperatures, and often in combination...... electron microscopy, and the compositional analysis of the corrosion products and contaminants was performed using energy dispersive X-ray spectroscopy. Wear track morphology was observed on the contact points, and the top coating on the dome was worn out exposing the substrate spring material...

  13. Influence of tyre-road contact model on vehicle vibration response

    Science.gov (United States)

    Múčka, Peter; Gagnon, Louis

    2015-09-01

    The influence of the tyre-road contact model on the simulated vertical vibration response was analysed. Three contact models were compared: tyre-road point contact model, moving averaged profile and tyre-enveloping model. In total, 1600 real asphalt concrete and Portland cement concrete longitudinal road profiles were processed. The linear planar model of automobile with 12 degrees of freedom (DOF) was used. Five vibration responses as the measures of ride comfort, ride safety and dynamic load of cargo were investigated. The results were calculated as a function of vibration response, vehicle velocity, road quality and road surface type. The marked differences in the dynamic tyre forces and the negligible differences in the ride comfort quantities were observed among the tyre-road contact models. The seat acceleration response for three contact models and 331 DOF multibody model of the truck semi-trailer was compared with the measured response for a known profile of test section.

  14. Inter- and intra-rater reliability of patellofemoral kinematic and contact area quantification by fast spin echo MRI and correlation with cartilage health by quantitative T1ρ MRI.

    Science.gov (United States)

    Lau, Brian C; Thuillier, Daniel U; Pedoia, Valentina; Chen, Ellison Y; Zhang, Zhihong; Feeley, Brian T; Souza, Richard B

    2016-01-01

    Patellar maltracking is a leading cause of patellofemoral pain syndrome (PFPS). The aim of this study was to determine the inter- and intra-rater reliability of a semi-automated program for magnetic resonance imaging (MRI) based patellofemoral kinematics. Sixteen subjects (10 with PFPS [mean age 32.3; SD 5.2; eight females] and six controls without PFPS 19 [mean age 28.6; SD 2.8; three females]) participated in the study. One set of T2-weighted, fat-saturated fast spin-echo (FSE) MRIs were acquired from each subject in full extension and 30° of knee flexion. MRI including axial T1ρ relaxation time mapping sequences was also performed on each knee. Following image acquisitions, regions of interest for kinematic MRI, and patellar and trochlear cartilage were segmented and quantified with in-house designed spline- based MATLAB semi-automated software. Intraclass Correlations Coefficients (ICC) of calculated kinematic parameters were good to excellent, ICC > 0.8 in patellar flexion, rotation, tilt, and translation (anterior -posterior, medial -lateral, and superior -inferior), and contact area translation. Only patellar tilt in the flexed position and motion from extended to flexed state was significantly different between PFPS and control patients (p=0.002 and p=0.006, respectively). No significant correlations were identified between patellofemoral kinematics and contact area with T1ρ relaxation times. A semi-automated, spline-based kinematic MRI technique for patellofemoral kinematic and contact area quantification is highly reproducible with the potential to help better understand the role of patellofemoral maltracking in PFPS and other knee disorders. Level IV. Published by Elsevier B.V.

  15. Inter- and intra-rater reliability of patellofemoral kinematic and contact area quantification by fast spin echo MRI and correlation with cartilage health by quantitative T1ρ MRI☆

    Science.gov (United States)

    Lau, Brian C.; Thuillier, Daniel U.; Pedoia, Valentina; Chen, Ellison Y.; Zhang, Zhihong; Feeley, Brian T.; Souza, Richard B.

    2016-01-01

    Background Patellar maltracking is a leading cause of patellofemoral pain syndrome (PFPS). The aim of this study was to determine the inter- and intra-rater reliability of a semi-automated program for magnetic resonance imaging (MRI) based patellofemoral kinematics. Methods Sixteen subjects (10 with PFPS [mean age 32.3; SD 5.2; eight females] and six controls without PFPS 19 [mean age 28.6; SD 2.8; three females]) participated in the study. One set of T2-weighted, fat-saturated fast spin-echo (FSE) MRIs were acquired from each subject in full extension and 30° of knee flexion. MRI including axial T1ρ relaxation time mapping sequences was also performed on each knee. Following image acquisitions, regions of interest for kinematic MRI, and patellar and trochlear cartilage were segmented and quantified with in-house designed spline- based MATLAB semi-automated software. Results Intraclass Correlations Coefficients (ICC) of calculated kinematic parameters were good to excellent, ICC > 0.8 in patellar flexion, rotation, tilt, and translation (anterior -posterior, medial -lateral, and superior -inferior), and contact area translation. Only patellar tilt in the flexed position and motion from extended to flexed state was significantly different between PFPS and control patients (p = 0.002 and p = 0.006, respectively). No significant correlations were identified between patellofemoral kinematics and contact area with T1ρ relaxation times. Conclusions A semi-automated, spline-based kinematic MRI technique for patellofemoral kinematic and contact area quantification is highly reproducible with the potential to help better understand the role of patellofemoral maltracking in PFPS and other knee disorders. PMID:26746045

  16. A soft-contact model for computing safety margins in human prehension.

    Science.gov (United States)

    Singh, Tarkeshwar; Ambike, Satyajit

    2017-10-01

    The soft human digit tip forms contact with grasped objects over a finite area and applies a moment about an axis normal to the area. These moments are important for ensuring stability during precision grasping. However, the contribution of these moments to grasp stability is rarely investigated in prehension studies. The more popular hard-contact model assumes that the digits exert a force vector but no free moment on the grasped object. Many sensorimotor studies use this model and show that humans estimate friction coefficients to scale the normal force to grasp objects stably, i.e. the smoother the surface, the tighter the grasp. The difference between the applied normal force and the minimal normal force needed to prevent slipping is called safety margin and this index is widely used as a measure of grasp planning. Here, we define and quantify safety margin using a more realistic contact model that allows digits to apply both forces and moments. Specifically, we adapt a soft-contact model from robotics and demonstrate that the safety margin thus computed is a more accurate and robust index of grasp planning than its hard-contact variant. Previously, we have used the soft-contact model to propose two indices of grasp planning that show how humans account for the shape and inertial properties of an object. A soft-contact based safety margin offers complementary insights by quantifying how humans may account for surface properties of the object and skin tissue during grasp planning and execution. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Effect of surfaces similarity on contact resistance of fractal rough surfaces under cyclic loading

    Science.gov (United States)

    Gao, Yuanwen; Liu, Limei; Ta, Wurui; Song, Jihua

    2018-03-01

    Although numerous studies have shown that contact resistance depends significantly on roughness and fractal dimension, it remains elusive how they affect contact resistance between rough surfaces. The interface similarity index is first proposed to describe the similarity of the contact surfaces, which gives a good indication of the actual contact area between surfaces. We reveal that the surfaces' similarity be an origin of contact resistance variation. The cyclic loading can increase the contact stiffness, and the contact stiffness increases with the increase of the interface similarity index. These findings explain the mechanism of surface roughness and fractal dimension on contact resistance, and also provide reference for the reliability design of the electrical connection.

  18. [The usage of protective gloves for routine disinfection of patient contact areas : An anonymous survey of work doctors and hygienists (infection control nurses, link nurses and physicians)].

    Science.gov (United States)

    Dittmann, Kathleen; Morch-Röder, Alexandra; Kramer, Axel; Kagel, Verena; Hübner, Nils-Olaf

    2017-10-01

    Disinfection, routinely carried out in healthcare facilities and known as "ongoing disinfection" or "untargeted disinfection", covers areas that are suspected of being contaminated with pathogen-containing material without being recognizable or visible in individual cases. The use of chemical resistant protective gloves is indispensable for surface disinfection. However, it is unclear if healthcare facilities set specific requirements regarding the selection and application of gloves. The usage of protective gloves for routine disinfection of patient contact areas was assessed in an anonymous cross-sectional study. Work doctors and hygienists (infection control nurses, link nurses and physicians) were queried by questionnaire. Disposable gloves were predominantly used, in most cases largely in accordance with EN 374. The most common glove material was nitrile. Glove change was mostly reported between rooms. Reprocessing of reusable gloves is inconsistent. Several professions are responsible for selecting protective gloves. Procedures for glove selection and application for disinfection of contact surfaces vary between the surveyed institutions. Therefore, more attention has to be paid to these three aspects in the future and these must be included in the hygiene plans.

  19. Patch test results in patients with allergic contact dermatitis in Yozgat

    Directory of Open Access Journals (Sweden)

    Emine Çölgeçen Özel

    2013-09-01

    Full Text Available Background and Design: Patch testing is valuable in the diagnosis of allergic contact dermatitis (ACD as well as in determining the causative agent and thus is helpful in prevention of the disease and also provides information for the patient Material and Method: Hundred and sixty-eight patients (94 female and 74 male with ACD were patch tested with European standard series. Patch test result were assessed according to suggestion of International Contact Dermatitis Research Group at 48 and 72 hours after initial application. Results: Of the patients, 64.3% were between 16-45 years of age and majority of the lesions (57.1% were localized on the hands. A total of 86 (51.1% patients had one or more positive patch test reactions. The most common allergens were nickel sulfate (20.2% followed by potassium dichromate (8.3%, cobalt chloride (7.1%, fragrance mix (7.1%, paraphenylendiamine base (6%, paraben mix 3.6%, N-isopropyl-N-phenyl-p-phenylenediamine (3.6%, wool alcohols (3.6%, formaldehyde (3.6%, quaternium-15 (3.6%. Positive reactions to nickel sulfate were more common among women, especially those in younger group. Frequency of contact allergy to neomycin sulfate, epoxy resin, 4-tert-butylphenolformaldehyde resin, sesquiterpenelactone mix, primin, 5-chloro-2-methyl-4-isothiazolin-3-1, budesonide, lyral were relatively low (1.2%, while no positive reaction was obtained to clioquinol and methyldibromoglutaronitrile in any case. Conclusion: Since no similar study has been previously performed in our area, this study provides information about contact allergen profile in patients underwent skin patch test with a diagnosis of AKD at Yozgat. The most frequent allergens detected with ASS and frequency rates may vary among different facilities at various cities of Turkey. A standard series for our country may be created after assessment of regional variability by new studies conducted in same time zone.

  20. Lifestyle factors and contact to general practice with respiratory alarm symptoms

    DEFF Research Database (Denmark)

    Sele, Lisa Maria Falk; Elnegaard, Sandra; Balasubramaniam, Kirubakaran

    2016-01-01

    BACKGROUND: A prerequisite for early lung cancer diagnosis is that individuals with respiratory alarm symptoms (RAS) contact a general practitioner (GP). This study aims to determine the proportion of individuals in the general population who contact a GP with RAS and to analyse the association...... between lifestyle factors and contact to GPs with RAS. METHODS: A web-based survey of 100 000 individuals randomly selected from the Danish Civil Registration System. Items regarding experience of RAS (prolonged coughing, shortness of breath, coughing up blood, and prolonged hoarseness), GP contacts......, and lifestyle factors (smoking status, alcohol intake, and body mass index) were included. RESULTS: In total 49 706 (52.5 %) individuals answered the questionnaire. Overall 7870 reported at least one respiratory alarm symptom, and of those 39.6 % (3 080) had contacted a GP. Regarding specific symptoms...

  1. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan

    2013-08-31

    We present the results of the assessment of the intramolecular residue-residue contact predictions from 26 prediction groups participating in the 10th round of the CASP experiment. The most recently developed direct coupling analysis methods did not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i.e., prediction accuracy and the difference between the distribution of the predicted contacts and that of all pairs of residues in the target protein), as well as new measures, such as the Matthews correlation coefficient, the area under the precision-recall curve and the ranks of the first correctly and incorrectly predicted contact. We also evaluated the ability to detect interdomain contacts and tested whether the difficulty of predicting contacts depends upon the protein length and the depth of the family sequence alignment. The analyses were carried out on the target domains for which structural homologs did not exist or were difficult to identify. The evaluation was performed for all types of contacts (short, medium, and long-range), with emphasis placed on long-range contacts, i.e. those involving residues separated by at least 24 residues along the sequence. The assessment suggests that the best CASP10 contact prediction methods perform at approximately the same level, and comparably to those participating in CASP9.

  2. Radiofrequency contact currents: sensory responses and dosimetry

    International Nuclear Information System (INIS)

    Kavet, Robert; Tell, R.A.; Olsen, R.G.

    2014-01-01

    The process of setting science-based exposure standards (or guidelines) for radiofrequency (RF) contact current exposure has been disadvantaged by a lack of relevant data. The authors first review the essential features and results of the available studies and illustrate the apparent discrepancies among them. Then, they examine the manner in which current was administered in these studies and suggest as to how the physical relationship of a contacting finger to the current electrode may play a role in affecting sensory thresholds specific to those configurations. A major factor in this analysis relates to whether current density is uniformly distributed across the contact area or whether an electrode's 'edge effects' enhance currents with a net effect of decreasing apparent thresholds, when expressed as the bulk current entering a subject. For an exposure with a clear hazard potential, thresholds of human sensory response to RF currents require further investigation. (authors)

  3. Prevalence of Pulmonary Tuberculosis among Household Contacts in Hyderabad, Sindh: Active Contact Tracing in Children with Tuberculosis

    International Nuclear Information System (INIS)

    Sheikh, M.A.; Shah, S.A.A.

    2017-01-01

    Background: Tuberculosis (TB) in children is clearly linked to TB in adults therefore active household contact tracing is an important method of early diagnosis and treatment particularly in high-TB-burden countries. Objectives: To estimate the prevalence of TB among household contacts of children suffering from tuberculosis using active contact tracing and linking them to TB program for treatment. Subjects and Methods: A total of 125 children suffering from active tuberculosis (index cases)aged 12 years or less were randomly selected from the outpatient department of a tertiary care hospital of Hyderabad. Using their home address, all house hold members of the index cases (sharing one kitchen) were identified. The households were visited by a team including a doctor and the supported staff and were screened for TB using history, physical examination, sputum for AFB and X-ray of chest. Clinical suspects were divided in to two populations, equal to or less than 12 years of age and greater than this age. All suspected cases were brought to outpatient's department of the hospital where children were examined and diagnosed by pediatrician and adults were examined by the pulmonologist. Results: There were 125 children and 1365 household members. Prevalence of active TB in adult household contacts was 8.1 percent and among children was 5.7 percent. Mother, father, grand parents or siblings were the source of disease spread in children. Family history of TB was present in 95 percent (pulmonary 78 percent, extra-pulmonary 22 percent). Conclusion: Tuberculosis in children is mostly spreading from household member hence deeply required to undertake active contact tracing in each new case that is diagnosed or being treated. Policy message: National and Provincial TB programs should advocate and undertake active screening of all household contacts of all TB cases. (author)

  4. Contact Mechanics of a Small Icosahedral Virus

    NARCIS (Netherlands)

    Zeng, Cheng; Hernando-Pérez, Mercedes; Ma, Xiang; Schoot, Paul van der; Zandi, Roya; Dragnea, Bogdan

    2017-01-01

    Virus binding to a surface results at least locally, at the contact area, in stress and potential structural perturbation of the virus cage. Here we address the question of the role of substrate-induced deformation in the overall virus mechanical response to the adsorption event. This question may

  5. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    Science.gov (United States)

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  6. Evaluation of metal–nanowire electrical contacts by measuring contact end resistance

    International Nuclear Information System (INIS)

    Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung

    2012-01-01

    It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)

  7. Deposition of lipid, protein, and secretory phospholipase A2 on hydrophilic contact lenses.

    Science.gov (United States)

    Mochizuki, Hiroshi; Yamada, Masakazu; Hatou, Shin; Kawashima, Motoko; Hata, Seiichiro

    2008-01-01

    Recent studies have shown that low tear phospholipid levels are associated with tear film instability in hydrophilic contact lens wearers. The concentration of secretory phospholipase A2 (sPLA2), the enzyme that hydrolyzes phospholipids, in tears is known to exceed the levels found in serum by four orders of magnitude. This study was performed to determine the levels of sPLA2 from the deposition on two different frequent-replacement contact lens materials. Polymacon and etafilcon A contact lenses worn for 2 weeks by 16 experienced contact lens wearers were used for the analysis. Total lipids were determined by the sulfo-phospho-vanillin reaction. Phospholipids in lipid extracts were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Total protein was measured by bicinchoninic acid analysis. Double-antibody sandwich enzyme-linked immunosorbent assay was used to determine sPLA2 concentrations. Total lipid deposition was found to be greater in the polymacon group (66.3+/-16.3 microg/lens) than in the etafilcon A group, although phospholipids were not detected in either group. The etafilcon A group had greater deposition of protein (3.7+/-0.7 mg/lens) than the polymacon group had. The etafilcon A group deposited statistically significantly more group IIa sPLA2 (1.1+/-0.3 microg/lens) than the polymacon group (0.07+/-0.04 microg/lens) did (P<0.001). There was a significant difference in the lipid and protein deposition profiles in the two lenses tested. A significant amount of sPLA2 in the deposition on contact lenses may play a role in tear film instability in hydrophilic contact lens wearers.

  8. Contextualizing Intergroup Contact: Do Political Party Cues Enhance Contact Effects?

    DEFF Research Database (Denmark)

    Sønderskov, Kim Mannemar; Thomsen, Jens Peter Frølund

    2015-01-01

    This article examines intergroup contact effects in different political contexts. We expand on previous efforts of social psychologists by incorporating the messages of political parties as a contextual trigger of group membership awareness in contact situations. We argue that the focus among...... political parties on us-them categorizations heightens the awareness of group memberships. This focus in turn enhances the positive intergroup contact effect by stimulating majority members to perceive contacted persons as prototypical outgroup members. A multilevel analysis of 22 countries and almost 37......,000 individuals confirms that the ability of intergroup contact to reduce antiforeigner sentiment increases when political parties focus intensively on immigration issues and cultural differences. Specifically, both workplace contact and interethnic friendship become more effective in reducing antiforeigner...

  9. Specific interface area in a thin layer system of two immiscible liquids with vapour generation at the contact interface

    Science.gov (United States)

    Pimenova, Anastasiya V.; Gazdaliev, Ilias M.; Goldobin, Denis S.

    2017-06-01

    For well-stirred multiphase fluid systems the mean interface area per unit volume, or “specific interface area” SV, is a significant characteristic of the system state. In particular, it is important for the dynamics of systems of immiscible liquids experiencing interfacial boiling. We estimate the value of parameter SV as a function of the heat influx {\\dot{Q}}V to the system or the average system overheat above the interfacial boiling point. The derived results can be reformulated for the case of an endothermic chemical reaction between two liquid reagents with the gaseous form of one of the reaction products. The final results are restricted to the case of thin layers, where the potential gravitational energy of bubbles leaving the contact interface is small compared to their surface tension energy.

  10. Surface Sediment Analysis on Petroleum Hydrocarbon and Total Organic Carbon from Coastal Area of Papar to Tuaran, Sabah

    International Nuclear Information System (INIS)

    Siti Aishah Mohd Ali; Payus, C.; Masni Mohd Ali

    2015-01-01

    Total petroleum hydrocarbons (TPH) and total organic carbon (TOC) were investigated in surface sediments along coastal area of Papar to Tuaran, Sabah. Surface sediment samples were collected in 24 different stations in each area by using Ponar grab sampler. Samples were extracted for TPH using standard method sediment/ sludge APHA 5520E and analyzed using UV/VIS spectrophotometer while for TOC method analysis using United Nations Environment Programme (UNEP)/ MAP Athens (2006). The range of TPH concentrations in surface sediments were recorded at 0.24 - 20.65 mg/ kg dw Miri crude oil equivalents, meanwhile the TOC percentage ranged from 0.03 - 4.02 %. In the mean time, the statistical analysis by Pearson correlation showed a positive correlation with coefficient, r = 0.790 which showing the TPH concentrations significantly have influence on the TOC accumulations in the surface sediment. (author)

  11. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  12. Risk factors and common contact allergens in facial allergic contact dermatitis patients.

    Science.gov (United States)

    Kasemsarn, Pranee; Iamphonrat, Thanawan; Boonchai, Waranya

    2016-04-01

    Facial dermatitis is commonly encountered in dermatologic practice. It is sometimes difficult to manage because its causative factors may be multiple and difficult to diagnose. This study was designed to identify the characteristics, patch test results, and final diagnoses of facial dermatitis patients who were referred to a contact dermatitis clinic and to identify factors associated with facial allergic contact dermatitis (ACD). We retrospectively reviewed case records of facial dermatitis patients who underwent patch testing at the clinic during the period from July 2006 to June 2011. Of the 891 patients patch-tested, 244 (27.4%) had facial dermatitis. Female patients were 9.1 times more predominant than male patients. The mean ± standard deviation age of patients was 37.3 ± 14.8 years. A total of 199 (81.6%) patients demonstrated at least one positive reaction to a patch test, 66.7% of which were clinically relevant. Allergic contact dermatitis was diagnosed in 45.5% of patients. Independent factors predisposing towards facial dermatitis were female sex, having a previous history of cosmetic allergy, a positive patch test reaction to hairdressing product-related allergens, and a positive allergic reaction to preservative allergens. The prevalence of facial dermatitis was 27.4%. Almost half of all patients with facial dermatitis demonstrated ACD. Factors associated with facial ACD were female gender, a history of cosmetic allergy, and positive patch test reactions to hairdressing product-related allergens and preservatives. © 2015 The International Society of Dermatology.

  13. Multi-Material Front Contact for 19% Thin Film Solar Cells

    Directory of Open Access Journals (Sweden)

    Joop van Deelen

    2016-02-01

    Full Text Available The trade-off between transmittance and conductivity of the front contact material poses a bottleneck for thin film solar panels. Normally, the front contact material is a metal oxide and the optimal cell configuration and panel efficiency were determined for various band gap materials, representing Cu(In,GaSe2 (CIGS, CdTe and high band gap perovskites. Supplementing the metal oxide with a metallic copper grid improves the performance of the front contact and aims to increase the efficiency. Various front contact designs with and without a metallic finger grid were calculated with a variation of the transparent conductive oxide (TCO sheet resistance, scribing area, cell length, and finger dimensions. In addition, the contact resistance and illumination power were also assessed and the optimal thin film solar panel design was determined. Adding a metallic finger grid on a TCO gives a higher solar cell efficiency and this also enables longer cell lengths. However, contact resistance between the metal and the TCO material can reduce the efficiency benefit somewhat.

  14. Tantalum Nitride Electron-Selective Contact for Crystalline Silicon Solar Cells

    KAUST Repository

    Yang, Xinbo

    2018-04-19

    Minimizing carrier recombination at contact regions by using carrier‐selective contact materials, instead of heavily doping the silicon, has attracted considerable attention for high‐efficiency, low‐cost crystalline silicon (c‐Si) solar cells. A novel electron‐selective, passivating contact for c‐Si solar cells is presented. Tantalum nitride (TaN x ) thin films deposited by atomic layer deposition are demonstrated to provide excellent electron‐transporting and hole‐blocking properties to the silicon surface, due to their small conduction band offset and large valence band offset. Thin TaNx interlayers provide moderate passivation of the silicon surfaces while simultaneously allowing a low contact resistivity to n‐type silicon. A power conversion efficiency (PCE) of over 20% is demonstrated with c‐Si solar cells featuring a simple full‐area electron‐selective TaNx contact, which significantly improves the fill factor and the open circuit voltage (Voc) and hence provides the higher PCE. The work opens up the possibility of using metal nitrides, instead of metal oxides, as carrier‐selective contacts or electron transport layers for photovoltaic devices.

  15. Shigella Infections in Household Contacts of Pediatric Shigellosis Patients in Rural Bangladesh.

    Science.gov (United States)

    George, Christine Marie; Ahmed, Shahnawaz; Talukder, Kaisar A; Azmi, Ishrat J; Perin, Jamie; Sack, R Bradley; Sack, David A; Stine, O Colin; Oldja, Lauren; Shahnaij, Mohammad; Chakraborty, Subhra; Parvin, Tahmina; Bhuyian, Sazzadul Islam; Bouwer, Edward; Zhang, Xiaotong; Hasan, Trisheeta N; Luna, Sharmin J; Akter, Fatema; Faruque, Abu S G

    2015-11-01

    To examine rates of Shigella infections in household contacts of pediatric shigellosis patients, we followed contacts and controls prospectively for 1 week after the index patient obtained care. Household contacts of patients were 44 times more likely to develop a Shigella infection than were control contacts (odds ratio 44.7, 95% CI 5.5-361.6); 29 (94%) household contacts of shigellosis patients were infected with the same species and serotype as the index patient's. Pulsed-field gel electrophoresis showed that 14 (88%) of 16 with infected contacts had strains that were indistinguishable from or closely related to the index patient's strain. Latrine area fly counts were higher in patient households compared with control households, and 2 patient household water samples were positive for Shigella. We show high susceptibility of household contacts of shigellosis patients to Shigella infections and found environmental risk factors to be targeted in future interventions.

  16. Should close contacts of returning travellers with typhoid fever be protected by vaccination?

    Science.gov (United States)

    Kantele, A

    2015-03-17

    Increasing international travel to areas endemic for typhoid fever correlates with increased risk for travellers to contract the disease. At home, the acutely ill/convalescent patients may pose some risk to their close contacts. In Finland an unofficial guideline suggests vaccination for close contacts of patients with acute typhoid fever; in other developed countries, routine typhoid vaccinations are only recommended to contacts of chronic carriers. This paper discusses the possibilities and limitations of prophylactic/post-exposure typhoid vaccination for contacts of patients with acute disease. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Acute non-contact anterior cruciate ligament tears are associated with relatively increased vastus medialis to semimembranosus cross-sectional area ratio: a case-control retrospective MR study

    International Nuclear Information System (INIS)

    Wieschhoff, Ged G.; Mandell, Jacob C.; Czuczman, Gregory J.; Nikac, Violeta; Shah, Nehal; Smith, Stacy E.

    2017-01-01

    Hamstring muscle deficiency is increasingly recognized as a risk factor for anterior cruciate ligament (ACL) tears. The purpose of this study is to evaluate the vastus medialis to semimembranosus cross-sectional area (VM:SM CSA) ratio on magnetic resonance imaging (MRI) in patients with ACL tears compared to controls. One hundred knee MRIs of acute ACL tear patients and 100 age-, sex-, and side-matched controls were included. Mechanism of injury, contact versus non-contact, was determined for each ACL tear subject. The VM:SM CSA was measured on individual axial slices with a novel method using image-processing software. One reader measured all 200 knees and the second reader measured 50 knees at random to assess inter-reader variability. The intraclass correlation coefficient (ICC) was calculated to evaluate for correlation between readers. T-tests were performed to evaluate for differences in VM:SM CSA ratios between the ACL tear group and control group. The ICC for agreement between the two readers was 0.991 (95% confidence interval 0.984-0.995). Acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.44 vs. 1.28; p = 0.005). Non-contact acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.48 vs. 1.20; p = 0.003), whereas contact acute ACL tear patients do not (1.23 vs. 1.26; p = 0.762). Acute non-contact ACL tears are associated with increased VM:SM CSA ratios, which may imply a relative deficiency in hamstring strength. This study also demonstrates a novel method of measuring the relative CSA of muscles on MRI. (orig.)

  18. Acute non-contact anterior cruciate ligament tears are associated with relatively increased vastus medialis to semimembranosus cross-sectional area ratio: a case-control retrospective MR study.

    Science.gov (United States)

    Wieschhoff, Ged G; Mandell, Jacob C; Czuczman, Gregory J; Nikac, Violeta; Shah, Nehal; Smith, Stacy E

    2017-11-01

    Hamstring muscle deficiency is increasingly recognized as a risk factor for anterior cruciate ligament (ACL) tears. The purpose of this study is to evaluate the vastus medialis to semimembranosus cross-sectional area (VM:SM CSA) ratio on magnetic resonance imaging (MRI) in patients with ACL tears compared to controls. One hundred knee MRIs of acute ACL tear patients and 100 age-, sex-, and side-matched controls were included. Mechanism of injury, contact versus non-contact, was determined for each ACL tear subject. The VM:SM CSA was measured on individual axial slices with a novel method using image-processing software. One reader measured all 200 knees and the second reader measured 50 knees at random to assess inter-reader variability. The intraclass correlation coefficient (ICC) was calculated to evaluate for correlation between readers. T-tests were performed to evaluate for differences in VM:SM CSA ratios between the ACL tear group and control group. The ICC for agreement between the two readers was 0.991 (95% confidence interval 0.984-0.995). Acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.44 vs. 1.28; p = 0.005). Non-contact acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.48 vs. 1.20; p = 0.003), whereas contact acute ACL tear patients do not (1.23 vs. 1.26; p = 0.762). Acute non-contact ACL tears are associated with increased VM:SM CSA ratios, which may imply a relative deficiency in hamstring strength. This study also demonstrates a novel method of measuring the relative CSA of muscles on MRI.

  19. Acute non-contact anterior cruciate ligament tears are associated with relatively increased vastus medialis to semimembranosus cross-sectional area ratio: a case-control retrospective MR study

    Energy Technology Data Exchange (ETDEWEB)

    Wieschhoff, Ged G.; Mandell, Jacob C.; Czuczman, Gregory J.; Nikac, Violeta; Shah, Nehal; Smith, Stacy E. [Brigham and Women' s Hospital, Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States)

    2017-11-15

    Hamstring muscle deficiency is increasingly recognized as a risk factor for anterior cruciate ligament (ACL) tears. The purpose of this study is to evaluate the vastus medialis to semimembranosus cross-sectional area (VM:SM CSA) ratio on magnetic resonance imaging (MRI) in patients with ACL tears compared to controls. One hundred knee MRIs of acute ACL tear patients and 100 age-, sex-, and side-matched controls were included. Mechanism of injury, contact versus non-contact, was determined for each ACL tear subject. The VM:SM CSA was measured on individual axial slices with a novel method using image-processing software. One reader measured all 200 knees and the second reader measured 50 knees at random to assess inter-reader variability. The intraclass correlation coefficient (ICC) was calculated to evaluate for correlation between readers. T-tests were performed to evaluate for differences in VM:SM CSA ratios between the ACL tear group and control group. The ICC for agreement between the two readers was 0.991 (95% confidence interval 0.984-0.995). Acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.44 vs. 1.28; p = 0.005). Non-contact acute ACL tear patients have an increased VM:SM CSA ratio compared to controls (1.48 vs. 1.20; p = 0.003), whereas contact acute ACL tear patients do not (1.23 vs. 1.26; p = 0.762). Acute non-contact ACL tears are associated with increased VM:SM CSA ratios, which may imply a relative deficiency in hamstring strength. This study also demonstrates a novel method of measuring the relative CSA of muscles on MRI. (orig.)

  20. American Contact Dermatitis Society Contact Allergy Management Program: An Epidemiologic Tool to Quantify Ingredient Usage.

    Science.gov (United States)

    Scheman, Andrew; Severson, David

    2016-01-01

    The usage prevalence of ingredients in topical products is important to dermatologists and industry. To determine the prevalence of methylisothiazolinone (MI) in various types of consumer products The Contact Allergy Management Program (CAMP) database was mapped and sorted in spreadsheet format to determine the prevalence of MI in various types of consumer products. Methylisothiazolinone was found in 13.2% of 4660 total products in CAMP. High usage of MI was seen in dishwashing products (64%), shampoos (53%), bathroom/kitchen/all-purpose cleaners (47%), hair conditioners (45%), hair dyes (43%), laundry additives/fresheners/softeners (30%), soaps/cleansers (29%), and surface cleaners/disinfectants (27%). Of the products containing MI, MI alone (without methylchloroisothiazolinone) was most common in makeup products (100%), cleaning/dish/laundry products (>99%), moisturizers (82%), shaving products (78%), sunscreens (71%), and antiaging products (67%). The American Contact Dermatitis Society's CAMP is a valuable tool to collect epidemiologic data on the incidence of specific ingredient usage in various types of topical products.

  1. Perspectives on setting limits for RF contact currents: a commentary.

    Science.gov (United States)

    Tell, Richard A; Tell, Christopher A

    2018-01-15

    Limits for exposure to radiofrequency (RF) contact currents are specified in the two dominant RF safety standards and guidelines developed by the Institute of Electrical and Electronics Engineers (IEEE) and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These limits are intended to prevent RF burns when contacting RF energized objects caused by high local tissue current densities. We explain what contact currents are and review some history of the relevant limits with an emphasis on so-called "touch" contacts, i.e., contact between a person and a contact current source during touch via a very small contact area. Contact current limits were originally set on the basis of controlling the specific absorption rate resulting from the current flowing through regions of small conductive cross section within the body, such as the wrist or ankle. More recently, contact currents have been based on thresholds of perceived heating. In the latest standard from the IEEE developed for NATO, contact currents have been based on two research studies in which thresholds for perception of thermal warmth or thermal pain have been measured. Importantly, these studies maximized conductive contact between the subject and the contact current source. This factor was found to dominate the response to heating wherein high resistance contact, such as from dry skin, can result in local heating many times that from a highly conductive contact. Other factors such as electrode size and shape, frequency of the current and the physical force associated with contact are found to introduce uncertainty in threshold values when comparing data across multiple studies. Relying on studies in which the contact current is minimized for a given threshold does not result in conservative protection limits. Future efforts to develop limits on contact currents should include consideration of (1) the basis for the limits (perception, pain, tissue damage); (2) understanding of the

  2. Evaluation of touch-sensitive screen tablet terminal button size and spacing accounting for effect of fingertip contact angle.

    Science.gov (United States)

    Nishimura, T; Doi, K; Fujimoto, H

    2015-08-01

    Touch-sensitive screen terminals enabling intuitive operation are used as input interfaces in a wide range of fields. Tablet terminals are one of the most common devices with a touch-sensitive screen. They have a feature of good portability, enabling use under various conditions. On the other hand, they require a GUI designed to prevent decrease of usability under various conditions. For example, the angle of fingertip contact with the display changes according to finger posture during operation and how the case is held. When a human fingertip makes contact with an object, the contact area between the fingertip and contact object increases or decreases as the contact angle changes. A touch-sensitive screen detects positions using the change in capacitance of the area touched by the fingertip; hence, differences in contact area between the touch-sensitive screen and fingertip resulting from different forefinger angles during operation could possibly affect operability. However, this effect has never been studied. We therefore conducted an experiment to investigate the relationship between size/spacing and operability, while taking the effect of fingertip contact angle into account. As a result, we have been able to specify the button size and spacing conditions that enable accurate and fast operation regardless of the forefinger contact angle.

  3. Contact allergy to isoeugenol and its derivatives

    DEFF Research Database (Denmark)

    Tanaka, Susumu; Royds, C; Buckley, Christopher D

    2004-01-01

    A total of 2261 (808 male, 1453 female) consecutive patients attending contact dermatitis clinics were patch tested to isoeugenol and its derivatives listed in the EU Inventory of Fragrance Ingredients. Positive reactions were found to isoeugenol in 40, transisoeugenol in 40, isoeugenyl acetate...... and 15/16 of those to isoeugenyl phenylacetate but in none of those 6 positive to isoeugenyl methyl ether and in neither of those 2 positive to benzyl isoeugenyl ether. Concomitant contact allergy between isoeugenol and its derivatives may occur through chemical cross-reactivity or local skin metabolism...... of the derivatives. It is more commonly observed with the esters rather than the ethers. Isoeugenyl acetate has been proposed as an alternative to isoeugenol, but there is a high degree of concomitant reactivity with isoeugenol....

  4. Influence of lake surface area and total phosphorus on annual bluegill growth in small impoundments of central Georgia

    Science.gov (United States)

    Jennings, Cecil A.; Sundmark, Aaron P.

    2017-01-01

    The relationships between environmental variables and the growth rates of fishes are important and rapidly expanding topics in fisheries ecology. We used an informationtheoretic approach to evaluate the influence of lake surface area and total phosphorus on the age-specific growth rates of Lepomis macrochirus (Bluegill) in 6 small impoundments in central Georgia. We used model averaging to create composite models and determine the relative importance of the variables within each model. Results indicated that surface area was the most important factor in the models predicting growth of Bluegills aged 1–4 years; total phosphorus was also an important predictor for the same age-classes. These results suggest that managers can use water quality and lake morphometry variables to create predictive models specific to their waterbody or region to help develop lake-specific management plans that select for and optimize local-level habitat factors for enhancing Bluegill growth.

  5. Contact with friction modeling for the study of a bolted junction

    International Nuclear Information System (INIS)

    Lebon, F.; Raous, M.; Boulegues, D.

    1987-01-01

    Many structural analysis problems are concerned by contact phenomena. A good knowledge of the contact displacements and the contact forces between the different parts of the structure is generally essential in structure assembling. The special boundary behaviour has a strong influence on the distribution of the stresses in the whole structure and on his total fiability. The contact behaviour is strongly non linear because of the non penetration conditions on the one hand, and because of the friction on the other. On such problems the real contact zone and the contact forces are unknown 'a priori' and have to be determined during the resolution. The non-penetration is characterized by unilateral conditions and the friction is described by a constitutive law (Coulomb friction law). The application presented here concerns the assembling of the three parts of a bolted junction using a pressing ring. There are three contact zones in this program. A good description of the contact phenomena is essential to ensure tightness. Our methods are based on projection techniques coupled with overrelaxed Gauss-Seidel methods including condensation procedures (reduction of the number of variables). Non linear programming methods and iterative procedures on special boundary conditions are also used. (orig./HP)

  6. Experimental investigation on the electrical contact behavior of rolling contact connector

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Junxing; Yang, Fei, E-mail: yfei2007@mail.xjtu.edu.cn; Luo, Kaiyu; Zhu, Mingliang; Wu, Yi; Rong, Mingzhe [State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049 (China)

    2015-12-15

    Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.

  7. Unexpected Languages: Multilingualism and Contact in Eighteenth- and Nineteenth-Century North America

    Science.gov (United States)

    Phillips, Lisa

    2011-01-01

    This exploration of the languages of contact in the North American British-US borderlands in the period between 1783 and 1860 provides insights into the types of extended contact that occurred in the areas north of 42[degrees] and south of 50[degrees]. Although multilingualism was the norm in the Old Northwest and the old Oregon Territory during…

  8. The relationship between J waves and contact of lung cancer with the heart.

    Science.gov (United States)

    Hayashi, Hideki; Wu, Qi; Horie, Minoru

    2017-09-01

    J waves result mainly from an increased density of transient outward current (I to ). Mechanical stretch to the heart activates multiple signal transduction pathways, in which I to may be involved. The purpose of this study was to test the hypothesis that mechanical contact of lung cancer with the heart may manifest J waves. We reviewed 12-lead electrocardiograms to examine whether J waves were associated with contact of lung cancer with the heart. J waves were defied as an elevation of ≥0.1 mV at the junction between QRS complex and ST segment with either notching or slurring morphology. The locational interaction between lung cancer and the heart was determined by computed tomography image. A total of 264 patients (176 men; mean 68.5 ± 10.7 years) with lung cancer were evaluated. The prevalence of J waves was 25.4% in the total population. J waves were present in 40 of 44 (90.9%) patients with the contact. In contrast, J waves were present in 25 of 220 (11.4%) patients without the contact. The sensitivity and specificity of the contact for J waves were 90.9% and 88.6%, respectively. The odds ratio of the contact with the heart to the presence of J waves was 78 (95% confidence interval 25.7-236.4). The appearance of J waves that coincided with the development of lung cancer was observed in 12 patients. The presence of J waves was associated with the contact of lung cancer with the heart. © 2017 Wiley Periodicals, Inc.

  9. Low resistive edge contacts to CVD-grown graphene using a CMOS compatible metal

    Energy Technology Data Exchange (ETDEWEB)

    Shaygan, Mehrdad; Otto, Martin; Sagade, Abhay A.; Neumaier, Daniel [Advanced Microelectronic Center Aachen, AMO GmbH, Aachen (Germany); Chavarin, Carlos A. [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany); Innovations for High Performance Microelectronics, IHP GmbH, Frankfurt (Oder) (Germany); Bacher, Gerd; Mertin, Wolfgang [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany)

    2017-11-15

    The exploitation of the excellent intrinsic electronic properties of graphene for device applications is hampered by a large contact resistance between the metal and graphene. The formation of edge contacts rather than top contacts is one of the most promising solutions for realizing low ohmic contacts. In this paper the fabrication and characterization of edge contacts to large area CVD-grown monolayer graphene by means of optical lithography using CMOS compatible metals, i.e. Nickel and Aluminum is reported. Extraction of the contact resistance by Transfer Line Method (TLM) as well as the direct measurement using Kelvin Probe Force Microscopy demonstrates a very low width specific contact resistance down to 130 Ωμm. The contact resistance is found to be stable for annealing temperatures up to 150 C enabling further device processing. Using this contact scheme for edge contacts, a field effect transistor based on CVD graphene with a high transconductance of 0.63 mS/μm at 1 V bias voltage is fabricated. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    Energy Technology Data Exchange (ETDEWEB)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-12-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of /sup 111/indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential.

  11. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    International Nuclear Information System (INIS)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-01-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of 111 indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential

  12. Health sciences librarians, patient contact, and secondary traumatic stress.

    Science.gov (United States)

    Becker, Rachel W; McCrillis, Aileen

    2015-04-01

    The purpose of this study was to determine the prevalence of secondary traumatic stress (STS) in health sciences librarians (HSLs) who have direct contact with traumatized individuals and their families. A twenty-five-item survey and the Secondary Traumatic Stress Scale (STSS) were distributed via email to three Medical Library Association email discussion lists. A total of fifty-five HSLs responded to the survey. Survey results indicate moderate levels of STS and variability of symptoms among participants. Library and employee assistance program managers should be aware of the emotional toll of patient and/or family contact for HSLs.

  13. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    DEFF Research Database (Denmark)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant...... and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include...... genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet...

  14. Coordinate transformation in the model of long Josephson contacts: geometrically equivalent contacts

    International Nuclear Information System (INIS)

    Semerdzhieva, E.G.; Boyadzhiev, T.L.; ); Shukrinov, Yu.M.; Physical Technical Institute Dushanbe, 734063

    2005-01-01

    The transition from model of long Josephson variable-width contact to the contact model with coordinate-dependent Josephson current amplitude is realized by transforming the coordinates. This sets up a correspondence between Josephson contacts of variable width and quasi-one-dimensional contacts of variable thickness barrier layer. It is shown, that for contacts of exponentially varying width the barrier layer of the corresponding quasi-one-dimensional contact contains the distributed resistive inhomogeneity which is an attractor to magnetic flux vortices. With numerical experiments, a 'critical current-magnetic field' dependence for a resistive microinhomogeneity Josephson contact was plotted, and its comparison with the critical curve for a contact of exponentially varying width was made. Thus, this demonstrates that the distributed inhomogeneity may be replaced by a local one at the JC end what technologically, may offer definite advantages

  15. Simulation Results: Optimization of Contact Ratio for Interdigitated Back-Contact Solar Cells

    Directory of Open Access Journals (Sweden)

    Vinay Budhraja

    2017-01-01

    Full Text Available In the fabrication of interdigitated back contact (IBC solar cells, it is very important to choose the right size of contact to achieve the maximum efficiency. Line contacts and point contacts are the two possibilities, which are being chosen for IBC structure. It is expected that the point contacts would give better results because of the reduced recombination rate. In this work, we are simulating the effect of contact size on the performance of IBC solar cells. Simulations were done in three dimension using Quokka, which numerically solves the charge carrier transport. Our simulation results show that around 10% of contact ratio is able to achieve optimum cell efficiency.

  16. Methylisothiazolinone in rinse-off products causes allergic contact dermatitis

    DEFF Research Database (Denmark)

    Yazar, K; Lundov, Michael Dyrgaard; Faurschou, A

    2015-01-01

    the potential to cause allergic contact dermatitis. METHODS: Nineteen MI-allergic subjects and 19 controls without MI allergy applied two liquid hand soaps five times per day on areas of 5 × 10 cm(2) on the ventral side of their forearms. One soap contained 100 ppm MI, the maximum allowed concentration......BACKGROUND: In recent years, the prevalence of contact allergy to the preservative methylisothiazolinone (MI) has increased dramatically. Cosmetic products are one of the major sources of exposure. OBJECTIVES: To examine whether allowed concentrations of MI in cosmetic rinse-off products have...

  17. Industrially feasible, dopant-free, carrier-selective contacts for high-efficiency silicon solar cells

    KAUST Repository

    Yang, Xinbo

    2017-05-31

    Dopant-free, carrier-selective contacts (CSCs) on high efficiency silicon solar cells combine ease of deposition with potential optical benefits. Electron-selective titanium dioxide (TiO) contacts, one of the most promising dopant-free CSC technologies, have been successfully implemented into silicon solar cells with an efficiency over 21%. Here, we report further progress of TiO contacts for silicon solar cells and present an assessment of their industrial feasibility. With improved TiO contact quality and cell processing, a remarkable efficiency of 22.1% has been achieved using an n-type silicon solar cell featuring a full-area TiO contact. Next, we demonstrate the compatibility of TiO contacts with an industrial contact-firing process, its low performance sensitivity to the wafer resistivity, its applicability to ultrathin substrates as well as its long-term stability. Our findings underscore the great appeal of TiO contacts for industrial implementation with their combination of high efficiency with robust fabrication at low cost.

  18. Accumulation of total mercury and methylmercury in rice plants collected from different mining areas in China

    International Nuclear Information System (INIS)

    Meng, Mei; Li, Bing; Shao, Jun-juan; Wang, Thanh; He, Bin; Shi, Jian-bo; Ye, Zhi-hong; Jiang, Gui-bin

    2014-01-01

    A total of 155 rice plants were collected from ten mining areas in three provinces of China (Hunan, Guizhou and Guangdong), where most of mercury (Hg) mining takes place in China. During the harvest season, whole rice plants were sampled and divided into root, stalk and leaf, husk and seed (brown rice), together with soil from root zone. Although the degree of Hg contamination varied significantly among different mining areas, rice seed showed the highest ability for methylmercury (MeHg) accumulation. Both concentrations of total mercury (THg) and MeHg in rice plants were significantly correlated with Hg levels in soil, indicating soil is still an important source for both inorganic mercury (IHg) and MeHg in rice plants. The obvious discrepancy between the distribution patterns of THg and MeHg reflected different pathways of IHg and MeHg accumulation. Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- Highlights: • Distribution patterns indicated different pathways of IHg and MeHg accumulation. • Soil is an important source for both THg and MeHg to rice plants. • Water soluble Hg may play more important role in MeHg accumulation in rice plants. -- The distribution patterns indicate different pathways of IHg and MeHg accumulation in rice plants

  19. Effect of Tabor parameter on hysteresis losses during adhesive contact

    Science.gov (United States)

    Ciavarella, M.; Greenwood, J. A.; Barber, J. R.

    2017-01-01

    The Tabor parameter μ is conventionally assumed to determine the range of applicability of the classical 'JKR' solution for adhesive elastic contact of a sphere and a plane, with the variation of the contact area and approach with load, and in particular the maximum tensile force (the pull-off force) being well predicted for μ > 5 . Here we show that the hysteretic energy loss during a contact separation cycle is significantly overestimated by the JKR theory, even at quite large values of μ. This stems from the absence of long-range tensile forces in the JKR theory, which implies that jump into contact is delayed until the separation α = 0 . We develop an approximate solution based on the use of Wu's solution with van der Waals interactions for jump-in, and the JKR theory for jump out of contact, and show that for μ > 5 , the predicted hysteresis loss is then close to that found by direct numerical solutions using the Lennard-Jones force law. We also show how the same method can be adapted to allow for contact between bodies with finite support stiffness.

  20. First contact diagnosis and management of contact lens-related complications.

    Science.gov (United States)

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  1. Defects in Al casting alloy in contact with Ni coat - as the Frenkla effect

    Directory of Open Access Journals (Sweden)

    A. Patejuk

    2007-04-01

    Full Text Available The subjects of analysis of this work are the defects occurring in the contact area of aluminium and nickel. The purpose of this work was to do a model research. The research concerns the mechanism of the occurrence of the defects in the area of contact: aluminium alloy - nickel coat. The model research describes the making of joints between the above mentioned metals in the warming temperature lower than the time of melting temperature of aluminium and the time of welding. It was affirmed that these defects appear as the result of special diffusion - presented in professional literature as the Kirkendall - Frenkla. The made analysis of results allowed to define parameters and factors of pores - appearing it defined plane shifting in the line of parting between the metals. Appearing of three zones of diffusive alloy was observed in the contact area of given (examined metals. Observed phenomenon of the Frenkl porosity appeared in the area of the occurrence of the Al3Ni and Al3Ni + Al phases.

  2. Effect of the cut off frequency on rough point and flat surface contacts

    International Nuclear Information System (INIS)

    Meng, Fan Ming

    2012-01-01

    In the past years, contact between two bodies has been studied from various ways that do not consider the cut off frequency effect on the contact mechanism. This paper reports the correlation between rough point contact and flat surface contact at different cut off frequencies of filter. The similarity and difference between the two types of contact mechanisms are presented for materials with linear or elastic perfectly plastic deformation. The conjugate gradient method (CGM) is used for analysing the rough point contact, while the rough flat surface contact is studied with an improved CGM in which the influence coefficient for the elastic deformation of the rough flat surface is obtained with finite element method. Numerical results show that for the above two types of contacts, their von Mises stress and maximum shear stress are greatly affected by the cut-off frequency of a high pass filter. Moreover, a decrease in the cut-off frequency leads to an increase in the contact area and a decrease in the approach for the rough flat surface contact, while the opposite variations is for the point contact between rough bodies with the small radii

  3. Reverse-contact UV nanoimprint lithography for multilayered structure fabrication

    DEFF Research Database (Denmark)

    Kehagias, N.; Reboud, V.; Chansin, G.

    2007-01-01

    In this paper, we report results on a newly developed nanofabrication technique, namely reverse-contact UV nanoimprint lithography. This technique is a combination of nanoimprint lithography and contact printing lithography. In this process, a lift-off resist and a UV cross-linkable polymer...... are spin-coated successively onto a patterned UV mask-mould. These thin polymer films are then transferred from the mould to the substrate by contact at a suitable temperature and pressure. The whole assembly is then exposed to UV light. After separation of the mould and the substrate, the unexposed...... polymer areas are dissolved in a developer solution leaving behind the negative features of the original stamp. This method delivers resist pattern transfer without a residual layer, thereby rending unnecessary the etching steps typically needed in the imprint lithography techniques for three...

  4. Synchrotron radiation stimulated etching of SiO sub 2 thin films with a Co contact mask for the area-selective deposition of self-assembled monolayer

    CERN Document Server

    Wang, C

    2003-01-01

    The area-selective deposition of a self-assembled monolayer (SAM) was demonstrated on a pattern structure fabricated by synchrotron radiation (SR) stimulated etching of a SiO sub 2 thin film on the Si substrate. The etching was conducted by irradiating the SiO sub 2 thin film with SR through a Co contact mask and using a mixture of SF sub 6 + O sub 2 as the reaction gas. The SR etching stopped completely at the SiO sub 2 /Si interface. After the SR etching, the Si surface and the SiO sub 2 surface beneath the Co mask were evaluated by an atomic force microscope (AFM). A dodecene SAM was deposited on the Si surface, and trichlorosilane-derived SAMs (octadecyltrichlorosilane, and octenyltrichlorosilane) were deposited on the SiO sub 2 surface beneath the Co mask. The structure of the deposited SAMs showed a densely packed and well-ordered molecular architecture, which was characterized by infrared spectroscopy, ellipsometry, and water contact angle (WCA) measurements. (author)

  5. The effect of protein-coated contact lenses on the adhesion and viability of gram negative bacteria.

    Science.gov (United States)

    Williams, Timothy J; Schneider, Rene P; Willcox, Mark D P

    2003-10-01

    Gram negative bacterial adhesion to contact lenses can cause adverse responses. During contact lens wear, components of the tear film adsorb to the contact lens. This study aimed to investigate the effect of this conditioning film on the viability of bacteria. Bacteria adhered to contact lenses which were either unworn, worn for daily-, extended- or overnight-wear or coated with lactoferrin or lysozyme. Numbers of viable and total cells were estimated. The number of viable attached cells was found to be significantly lower than the total number of cells on worn (50% for strain Paer1 on daily-wear lenses) or lactoferrin-coated lenses (56% for strain Paer1). Lysozyme-coated lenses no statistically significant effect on adhesion. The conditioning film gained through wear may not inhibit bacterial adhesion, but may act adversely upon those bacteria that succeed in attaching.

  6. A Modified Approach in Modeling and Calculation of Contact Characteristics of Rough Surfaces

    Directory of Open Access Journals (Sweden)

    J.A. Abdo

    2005-12-01

    Full Text Available A mathematical formulation for the contact of rough surfaces is presented. The derivation of the contact model is facilitated through the definition of plastic asperities that are assumed to be embedded at a critical depth within the actual surface asperities. The surface asperities are assumed to deform elastically whereas the plastic asperities experience only plastic deformation. The deformation of plastic asperities is made to obey the law of conservation of volume. It is believed that the proposed model is advantageous since (a it provides a more accurate account of elasticplastic behavior of surfaces in contact and (b it is applicable to model formulations that involve asperity shoulder-to shoulder contact. Comparison of numerical results for estimating true contact area and contact force using the proposed model and the earlier methods suggest that the proposed approach provides a more realistic prediction of elastic-plastic contact behavior.

  7. Social network diversity and risks of ischemic heart disease and total mortality

    DEFF Research Database (Denmark)

    Barefoot, John C; Grønbaek, Morten; Jensen, Gorm

    2005-01-01

    Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991-1994, and pa......Measures of various types of social contacts were used as predictors of ischemic heart disease events and total mortality in an age-stratified random sample of 9,573 adults enrolled in the Copenhagen City Heart Study (Copenhagen, Denmark). Baseline examinations were conducted in 1991...

  8. Repulsion-based model for contact angle saturation in electrowetting.

    Science.gov (United States)

    Ali, Hassan Abdelmoumen Abdellah; Mohamed, Hany Ahmed; Abdelgawad, Mohamed

    2015-01-01

    We introduce a new model for contact angle saturation phenomenon in electrowetting on dielectric systems. This new model attributes contact angle saturation to repulsion between trapped charges on the cap and base surfaces of the droplet in the vicinity of the three-phase contact line, which prevents these surfaces from converging during contact angle reduction. This repulsion-based saturation is similar to repulsion between charges accumulated on the surfaces of conducting droplets which causes the well known Coulombic fission and Taylor cone formation phenomena. In our model, both the droplet and dielectric coating were treated as lossy dielectric media (i.e., having finite electrical conductivities and permittivities) contrary to the more common assumption of a perfectly conducting droplet and perfectly insulating dielectric. We used theoretical analysis and numerical simulations to find actual charge distribution on droplet surface, calculate repulsion energy, and minimize energy of the total system as a function of droplet contact angle. Resulting saturation curves were in good agreement with previously reported experimental results. We used this proposed model to predict effect of changing liquid properties, such as electrical conductivity, and system parameters, such as thickness of the dielectric layer, on the saturation angle, which also matched experimental results.

  9. Beyond bushmeat: animal contact, injury, and zoonotic disease risk in Western Uganda.

    Science.gov (United States)

    Paige, Sarah B; Frost, Simon D W; Gibson, Mhairi A; Jones, James Holland; Shankar, Anupama; Switzer, William M; Ting, Nelson; Goldberg, Tony L

    2014-12-01

    Zoonotic pathogens cause an estimated 70% of emerging and re-emerging infectious diseases in humans. In sub-Saharan Africa, bushmeat hunting and butchering is considered the primary risk factor for human-wildlife contact and zoonotic disease transmission, particularly for the transmission of simian retroviruses. However, hunting is only one of many activities in sub-Saharan Africa that bring people and wildlife into contact. Here, we examine human-animal interaction in western Uganda, identifying patterns of injuries from animals and contact with nonhuman primates. Additionally, we identify individual-level risk factors associated with contact. Nearly 20% (246/1,240) of participants reported either being injured by an animal or having contact with a primate over their lifetimes. The majority (51.7%) of injuries were dog bites that healed with no long-term medical consequences. The majority (76.8%) of 125 total primate contacts involved touching a carcass; however, butchering (20%), hunting (10%), and touching a live primate (10%) were also reported. Red colobus (Piliocolobus rufomitratus tephrosceles) accounted for most primate contact events. Multivariate logistic regression indicated that men who live adjacent to forest fragments are at elevated risk of animal contact and specifically primate contact. Our results provide a useful comparison to West and Central Africa where "bushmeat hunting" is the predominant paradigm for human-wildlife contact and zoonotic disease transmission.

  10. TEM/SEM investigation of microstructural changes within the white etching area under rolling contact fatigue and 3-D crack reconstruction by focused ion beam

    International Nuclear Information System (INIS)

    Grabulov, A.; Ziese, U.; Zandbergen, H.W.

    2007-01-01

    The white etching area (WEA) surrounding the cracks formed under high-cycle rolling contact fatigue was investigated by transmission electron microscopy (TEM) and Dual Beam (scanning electron microscopy (SEM)/focused ion beam). SEM revealed the initiation of cracks formed around artificially introduced Al 2 O 3 inclusions in the model steel (composition similar to SAE 52100). TEM investigations showed a microstructural difference between the WEA (formation of nanocrystalline ferrite) and the steel matrix (tempered martensitic structure). A three-dimensional image of the crack reconstructed from ∼400 Dual Beam cross-section images is reported

  11. Contact isotopic- and contact ion-exchange between two adsorbents

    International Nuclear Information System (INIS)

    Bunzl, K.; Mohan, R.; Haimerl, M.

    1975-01-01

    The kinetics of contact ion exchange processes between an ion exchange membrane and resin ion exchange beads, stirred in pure water, was investigated. A general criterion was derived, which indicates whether diffusion of the ions between the intermingling electric double layers or the collision frequency between the two adsorbents is the rate dermining step. Since the latter process proved to be rate controlling under our experimental conditions, the corresponding rate equations were derived under various initial and boundary conditions. Experimentally, the kinetics of contact isotopic exchange of Cs + - and Na + -ions as well as of the reverse contact ion exchange process of Cs + -versus Na + -ions were investigated by using Na 22 and Cs 137 radioisotopes. The experiments reveal in quantitative accord with the theory that the rate of collision controlled contact ion exchange processes depends mainly on the 'exchange coefficient', the separation factor and the collision frequency. While the latter two quantities were determined independently by separate experiments, the 'exchange coefficient' was evaluated from a contact isotopic exchange experiment. (orig.) [de

  12. ComplexContact: a web server for inter-protein contact prediction using deep learning

    KAUST Repository

    Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo

    2018-01-01

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  13. ComplexContact: a web server for inter-protein contact prediction using deep learning

    KAUST Repository

    Zeng, Hong

    2018-05-20

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  14. ComplexContact: a web server for inter-protein contact prediction using deep learning.

    Science.gov (United States)

    Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo

    2018-05-22

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  15. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis.

    Science.gov (United States)

    Koppes, Sjors A; Engebretsen, Kristiane A; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M; Khnykin, Denis; Molin, Sonja; Holm, Jan O; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F; Thyssen, Jacob P

    2017-07-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet to be described. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Predicted tyre-soil interface area and vertical stress distribution based on loading characteristics

    DEFF Research Database (Denmark)

    Schjønning, Per; Stettler, M.; Keller, Thomas

    2015-01-01

    The upper boundary condition for all models simulating stress patterns throughout the soil profile is the stress distribution at the tyre–soil interface. The so-called FRIDA model (Schjønning et al., 2008. Biosyst. Eng. 99, 119–133) treats the contact area as a superellipse and has been shown...... of the actual to recommended inflation pressure ratio. We found that VT and Kr accounted for nearly all variation in the data with respect to the contact area. The contact area width was accurately described by a combination of tyre width and Kr, while the superellipse squareness parameter, n, diminished...... slightly with increasing Kr. Estimated values of the contact area length related to observed data with a standard deviation of about 0.06 m. A difference between traction and implement tyres called for separate prediction equations, especially for the contact area. The FRIDA parameters α and β, reflecting...

  17. Quaternionic contact Einstein structures and the quaternionic contact Yamabe problem

    CERN Document Server

    Ivanov, Stefan; Vassilev, Dimiter

    2014-01-01

    A partial solution of the quaternionic contact Yamabe problem on the quaternionic sphere is given. It is shown that the torsion of the Biquard connection vanishes exactly when the trace-free part of the horizontal Ricci tensor of the Biquard connection is zero and this occurs precisely on 3-Sasakian manifolds. All conformal transformations sending the standard flat torsion-free quaternionic contact structure on the quaternionic Heisenberg group to a quaternionic contact structure with vanishing torsion of the Biquard connection are explicitly described. A "3-Hamiltonian form" of infinitesimal conformal automorphisms of quaternionic contact structures is presented.

  18. Contact Dermatitis in Pediatrics.

    Science.gov (United States)

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  19. Contact dermatitis to cobalt chloride with an unusual mechanism.

    Science.gov (United States)

    Arslan, Sevket; Aksan, Serkan; Ucar, Ramazan; Caliskaner, Ahmet Zafer

    2015-10-01

    Contact dermatitis is a frequent inflammatory skin disease. A suspected diagnosis is based on clinical symptoms, a plausible contact to allergens and a suitable history of dermatitis. Therefore, careful diagnosis by patch testing is of great importance because the patch testing is important to find out which allergen/material causes the complaints. Metallic allergens such as cobalt are among the most common causes of allergic contact dermatitis, but frequencies of contact dermatitis to these allergens may vary in different skin areas. Here, we report an unusual case of cobalt allergy on the skin contact with the prosthetic leg of a 30-year-old female patient. The patient developed maculopapular and vesicular lesions on her contact region of residual limb to prosthetic leg. She underwent standard patch testing, which resulted in a strong positive reaction to cobalt chloride. This case report may serve to remind doctors to be aware of potential allergic reactions to prostheses and to enable them to recognize a metal allergy if it appears. Prosthetists should also be reminded of potential allergic reactions. Cobalt can be used as an accelerator in making a prosthetic socket. Several cases have been reported concerning allergies to components of the prosthetic socket. This is the first report of sensitization to cobalt which is used in making a prosthetic leg. © The International Society for Prosthetics and Orthotics 2014.

  20. Program Contacts for Lake Pontchartrain Area/New Orleans (Louisiana)

    Science.gov (United States)

    Lake Pontchartrain Area/New Orleans (Louisiana) of the Urban Waters Federal Partnership (UWFP) reconnects urban communities with their waterways by improving coordination among federal agencies and collaborating with community-led efforts

  1. Nonlocal laser annealing to improve thermal contacts between multi-layer graphene and metals

    International Nuclear Information System (INIS)

    Ermakov, Victor A; Alaferdov, Andrei V; Vaz, Alfredo R; Moshkalev, Stanislav A; Baranov, Alexander V

    2013-01-01

    The accuracy of thermal conductivity measurements by the micro-Raman technique for suspended multi-layer graphene flakes has been shown to depend critically on the quality of the thermal contacts between the flakes and the metal electrodes used as the heat sink. The quality of the contacts can be improved by nonlocal laser annealing at increased power. The improvement of the thermal contacts to initially rough metal electrodes is attributed to local melting of the metal surface under laser heating, and increased area of real metal–graphene contact. Improvement of the thermal contacts between multi-layer graphene and a silicon oxide surface was also observed, with more efficient heat transfer from graphene as compared with the graphene–metal case. (paper)

  2. Contact Tools in Japanese Acupuncture: An Ethnography of Acupuncture Practitioners in Japan.

    Science.gov (United States)

    Chant, Benjamin Cw; Madison, Jeanne; Coop, Paul; Dieberg, Gudrun

    2017-10-01

    This study aimed to identify procedural elements of Japanese acupuncture, describe these elements in detail, and explain them in terms of the key thematic category of treatment principles. Between August 2012 and December 2016, ethnographic fieldwork was conducted in Japan. In total, 38 participants were recruited by chain referral and emergent sampling. Data was collected through participant observation, interviews, and by analyzing documents. A total of 22 participants agreed to clinical observation; 221 treatments were observed with 172 patients. Seventeen consented to formal interviews and 28 to informal interviews. Thematic analysis was used to critically evaluate data. One especially interesting theme was interpreted from the data: a variety of contact tools were applied in treatment and these were manipulated by adjusting elements of form, speed, repetition, and pressure. Tapping, holding, pressing/pushing, and stroking were the most important ways contact tools were used on patients. Contact tools are noninvasive, painless, can be applied in almost any environment, and may be easily accepted by patients worldwide. Contact tool theory and practice may be successfully integrated into acupuncture curricula outside of Japan, used to inform clinical trials, and contribute to an expanded repertoire of methods for practitioners to benefit individual patients in international contexts. Copyright © 2017. Published by Elsevier B.V.

  3. Projecting social contact matrices in 152 countries using contact surveys and demographic data.

    Directory of Open Access Journals (Sweden)

    Kiesha Prem

    2017-09-01

    Full Text Available Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school, and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for

  4. Projecting social contact matrices in 152 countries using contact surveys and demographic data.

    Science.gov (United States)

    Prem, Kiesha; Cook, Alex R; Jit, Mark

    2017-09-01

    Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school), and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for societies for which

  5. Contact allergy and allergic contact dermatitis in adolescents: prevalence measures and associations

    DEFF Research Database (Denmark)

    Mørtz, Charlotte G; Lauritsen, Jens Martin; Bindslev-Jensen, Carsten

    2002-01-01

    The aims of this cross-sectional study were to establish the prevalence measures of contact allergy and allergic contact dermatitis in 8th grade schoolchildren (aged 12-16 years) in Odense, Denmark, and to examine the associations with atopic dermatitis, inhalant allergy and hand eczema. Contact...... allergy to a standard series allergen was found in 15.2% of schoolchildren. The point prevalence of allergic contact dermatitis was 0.7% and the lifetime prevalence 7.2%, predominantly in girls. The most common contact allergens were nickel (8.6%) and fragrance mix (1.8%). Nickel allergy was clinically...... relevant in 69% and fragrance allergy in 29% of cases. A significant association was found between contact allergy and hand eczema while no association was found between contact allergy and atopic dermatitis or inhalant allergy. In the future this cohort of schoolchildren will be followed with regard...

  6. Contact angle of sessile drops in Lennard-Jones systems.

    Science.gov (United States)

    Becker, Stefan; Urbassek, Herbert M; Horsch, Martin; Hasse, Hans

    2014-11-18

    Molecular dynamics simulations are used for studying the contact angle of nanoscale sessile drops on a planar solid wall in a system interacting via the truncated and shifted Lennard-Jones potential. The entire range between total wetting and dewetting is investigated by varying the solid-fluid dispersive interaction energy. The temperature is varied between the triple point and the critical temperature. A correlation is obtained for the contact angle in dependence of the temperature and the dispersive interaction energy. Size effects are studied by varying the number of fluid particles at otherwise constant conditions, using up to 150,000 particles. For particle numbers below 10,000, a decrease of the contact angle is found. This is attributed to a dependence of the solid-liquid surface tension on the droplet size. A convergence to a constant contact angle is observed for larger system sizes. The influence of the wall model is studied by varying the density of the wall. The effective solid-fluid dispersive interaction energy at a contact angle of θ = 90° is found to be independent of temperature and to decrease linearly with the solid density. A correlation is developed that describes the contact angle as a function of the dispersive interaction, the temperature, and the solid density. The density profile of the sessile drop and the surrounding vapor phase is described by a correlation combining a sigmoidal function and an oscillation term.

  7. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    NARCIS (Netherlands)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M.; Khnykin, Denis; Molin, Sonja; Holm, Jan O.; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F.; Thyssen, Jacob P.

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and

  8. Impact of measurable physical phenomena on contact thermal comfort

    Science.gov (United States)

    Fojtlín, Miloš; Pokorný, Jan; Fišer, Jan; Toma, Róbert; Tuhovčák, Ján

    Cabin HVAC (Heating Ventilation and Air-conditioning) systems have become an essential part of personal vehicles as demands for comfortable transport are still rising. In fact, 85 % of the car trips in Europe are shorter than 18 km and last only up to 30 minutes. Under such conditions, the HVAC unit cannot often ensure desired cabin environment and passengers are prone to experience thermal stress. For this reason, additional comfort systems, such as heated or ventilated seats, are available on the market. However, there is no straightforward method to evaluate thermal comfort at the contact surfaces nowadays. The aim of this work is to summarise information about heated and ventilated seats. These technologies use electrical heating and fan driven air to contact area in order to achieve enhanced comfort. It is also expected, that such measures may contribute to lower energy consumption. Yet, in real conditions it is almost impossible to measure the airflow through the ventilated seat directly. Therefore, there is a need for an approach that would correlate measurable physical phenomena with thermal comfort. For this reason, a method that exploits a measurement of temperatures and humidity at the contact area is proposed. Preliminary results that correlate comfort with measurable physical phenomena are demonstrated.

  9. Impact of measurable physical phenomena on contact thermal comfort

    Directory of Open Access Journals (Sweden)

    Fojtlín Miloš

    2017-01-01

    Full Text Available Cabin HVAC (Heating Ventilation and Air-conditioning systems have become an essential part of personal vehicles as demands for comfortable transport are still rising. In fact, 85 % of the car trips in Europe are shorter than 18 km and last only up to 30 minutes. Under such conditions, the HVAC unit cannot often ensure desired cabin environment and passengers are prone to experience thermal stress. For this reason, additional comfort systems, such as heated or ventilated seats, are available on the market. However, there is no straightforward method to evaluate thermal comfort at the contact surfaces nowadays. The aim of this work is to summarise information about heated and ventilated seats. These technologies use electrical heating and fan driven air to contact area in order to achieve enhanced comfort. It is also expected, that such measures may contribute to lower energy consumption. Yet, in real conditions it is almost impossible to measure the airflow through the ventilated seat directly. Therefore, there is a need for an approach that would correlate measurable physical phenomena with thermal comfort. For this reason, a method that exploits a measurement of temperatures and humidity at the contact area is proposed. Preliminary results that correlate comfort with measurable physical phenomena are demonstrated.

  10. [HORIZONTAL TRANSMISSION OF HBV INFECTION IN MIGRANTSFROM A HYPERENDEMIC AREA TO THEIR CONTACTS IN A LOW ENDEMICITY AREA IN PERU

    Science.gov (United States)

    Cabezas, César; Anaya, Elizabeth; Bartalesi, Filippo; Sánchez, Jaime

    1997-01-01

    Migration of inhabitants from high endemicity to low endemicity areas, where the majority of population is susceptible, implies a risk of transmission. This factor suggested the study of the presence of HBV infection on migrants from Huanta and in their host communities in Lima.MATERIAL AND METHODS: Forty families from a human settlement in the District of San Juan de Lurigancho, Lima, were chosen at random. This sample included migrant families and people who had born in Lima.The members of these families were subjected to a survey to obtain demographic data and possible risk factor for HBV infection, and venous blood sample was obtained to determine HBV serological markers by ELIZA techniques.RESULTS: A total of 215 people were evaluated, 130 (60,5%) were female, and 85 (39,5%) were male. There were 9 (4,2%) HbsAg carriers; 4 (1,9%) of them were born in Huanta; the other 5 (2,3%) were born in Lima, and had never been to Huanta. They were under 20 years of age. No significant association was found between the presence of HbsAg and the use of injectables, blood transfusions, tatoos, previous surgery, dental extractions or sexual relations.CONCLUSION: The presence of HbsAg carrier on people born in Lima, with no "classical" risk factor for HBV infection, could be associated with carriers migrating from a hyperendemic HBV area, suggesting a mechanism of horizontal transmission.

  11. Microbial counts of food contact surfaces at schools depending on a feeding scheme

    Directory of Open Access Journals (Sweden)

    Nthabiseng Nhlapo

    2014-11-01

    Full Text Available The prominence of disease transmission between individuals in confined environments is a concern, particularly in the educational environment. With respect to school feeding schemes, food contact surfaces have been shown to be potential vehicles of foodborne pathogens. The aim of this study was to assess the cleanliness of the surfaces that come into contact with food that is provided to children through the National School Nutrition Programme in central South Africa. In each school under study, microbiological samples were collected from the preparation surface and the dominant hand and apron of the food handler. The samples were analysed for total viable counts, coliforms, Escherichia coli, Staphylococcus aureus and yeasts and moulds. The criteria specified in the British Columbia Guide for Environmental Health Officers were used to evaluate the results. Total viable counts were high for all surfaces, with the majority of colonies being too numerous to count (over 100 colonies per plate. Counts of organisms were relatively low, with 20% of the surfaces producing unsatisfactory enumeration of S. aureus and E. coli and 30% unsatisfactory for coliforms. Yeast and mould produced 50% and 60% unsatisfactory counts from preparation surfaces and aprons, respectively. Statistically significant differences could not be established amongst microbial counts of the surfaces, which suggests cross-contamination may have occurred. Contamination may be attributed to foodstuffs and animals in the vicinity of the preparation area rather than to the food handlers, because hands had the lowest counts of enumerated organisms amongst the analysed surfaces.

  12. Vulnerability of Karangkates dams area by means of zero crossing analysis of data magnetic

    Energy Technology Data Exchange (ETDEWEB)

    Sunaryo,, E-mail: sunaryo@ub.ac.id, E-mail: sunaryo.geofis.ub@gmail.com; Susilo, Adi [Geophysics Program Study, Physics Dept., Sciences Faculty, University of Brawijaya, Malang (Indonesia)

    2015-04-24

    Study with entitled Vulnerability Karangkates Dam Area By Means of Zero Crossing Analysis of Data Magnetic has been done. The study was aimed to obtain information on the vulnerability of two parts area of Karangkates dams, i.e. Lahor dam which was inaugurated in 1977 and Sutami dam inaugurated in 1981. Three important things reasons for this study are: 1). The dam age was 36 years old for Lahor dam and 32 years old for Sutami dam, 2). Geologically, the location of the dams are closed together to the Pohgajih local shear fault, Selorejo local fault, and Selorejo limestone-andesite rocks contact plane, and 3). Karangkates dams is one of the important Hydro Power Plant PLTA with the generating power of about 400 million KWH per year from a total of about 29.373MW installed in Indonesia. Geographically, the magnetic data acquisition was conducted at coordinates (112.4149oE;-8.2028oS) to (112.4839oE;-8.0989oS) by using Proton Precession Magnetometer G-856. Magnetic Data acquisition was conducted in the radial direction from the dams with diameter of about 10 km and the distance between the measurements about 500m. The magnetic data acquisition obtained the distribution of total magnetic field value in the range of 45800 nT to 44450 nT. Residual anomalies obtained by doing some corrections, including diurnal correction, International Geomagnetic Reference Field (IGRF) correction, and reductions so carried out the distribution of the total magnetic field value in the range of -650 nT to 700 nT. Based on the residual anomalies, indicate the presence of 2 zones of closed closures dipole pairs at located in the west of the Sutami dam and the northwest of the Lahor dam from 5 total zones. Overlapping on the local geological map indicated the lineament of zero crossing patterns in the contour of residual anomaly contour with the Pohgajih shear fault where located at about 4 km to the west of the Sutami dam approximately and andesite-limestone rocks contact where located

  13. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  14. Noneczematous Contact Dermatitis

    Science.gov (United States)

    Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni

    2013-01-01

    Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520

  15. Local air gap thickness and contact area models for realistic simulation of human thermo-physiological response

    Science.gov (United States)

    Psikuta, Agnes; Mert, Emel; Annaheim, Simon; Rossi, René M.

    2018-02-01

    To evaluate the quality of new energy-saving and performance-supporting building and urban settings, the thermal sensation and comfort models are often used. The accuracy of these models is related to accurate prediction of the human thermo-physiological response that, in turn, is highly sensitive to the local effect of clothing. This study aimed at the development of an empirical regression model of the air gap thickness and the contact area in clothing to accurately simulate human thermal and perceptual response. The statistical model predicted reliably both parameters for 14 body regions based on the clothing ease allowances. The effect of the standard error in air gap prediction on the thermo-physiological response was lower than the differences between healthy humans. It was demonstrated that currently used assumptions and methods for determination of the air gap thickness can produce a substantial error for all global, mean, and local physiological parameters, and hence, lead to false estimation of the resultant physiological state of the human body, thermal sensation, and comfort. Thus, this model may help researchers to strive for improvement of human thermal comfort, health, productivity, safety, and overall sense of well-being with simultaneous reduction of energy consumption and costs in built environment.

  16. Apparent Contact Angle and Contact Angle Hysteresis on Liquid Infused Surfaces

    OpenAIRE

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-01-01

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a strong dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small b...

  17. The effect of contact precautions on healthcare worker activity in acute care hospitals.

    Science.gov (United States)

    Morgan, Daniel J; Pineles, Lisa; Shardell, Michelle; Graham, Margaret M; Mohammadi, Shahrzad; Forrest, Graeme N; Reisinger, Heather S; Schweizer, Marin L; Perencevich, Eli N

    2013-01-01

    Contact precautions are a cornerstone of infection prevention but have also been associated with less healthcare worker (HCW) contact and adverse events. We studied how contact precautions modified HCW behavior in 4 acute care facilities. Prospective cohort study. Four acute care facilities in the United States performing active surveillance for methicillin-resistant Staphylococcus aureus. Trained observers performed "secret shopper" monitoring of HCW activities during routine care, using a standardized collection tool and fixed 1-hour observation periods. A total of 7,743 HCW visits were observed over 1,989 hours. Patients on contact precautions had 36.4% fewer hourly HCW visits than patients not on contact precautions (2.78 vs 4.37 visits per hour; [Formula: see text]) as well as 17.7% less direct patient contact time with HCWs (13.98 vs 16.98 minutes per hour; [Formula: see text]). Patients on contact precautions tended to have fewer visitors (23.6% fewer; [Formula: see text]). HCWs were more likely to perform hand hygiene on exiting the room of a patient on contact precautions (63.2% vs 47.4% in rooms of patients not on contact precautions; [Formula: see text]). Contact precautions were found to be associated with activities likely to reduce transmission of resistant pathogens, such as fewer visits and better hand hygiene at exit, while exposing patients on contact precautions to less HCW contact, less visitor contact, and potentially other unintended outcomes.

  18. 21 CFR 886.5925 - Soft (hydrophilic) contact lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section 886.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as...

  19. Contact dermatitis in saffron workers: clinical profile and identification of contact sensitizers in a saffron-cultivating area of Kashmir Valley of North India.

    Science.gov (United States)

    Hassan, Iffat; Kamili, Afifa; Rasool, Farhan; Nehvi, Firdous; Rather, Parvaiz; Yasmin, Salwee; Pampori, Rafiq A; Jabeen, Yasmeen; Yaseen, Atiya; Bashir, Safia; Naaz, Saima

    2015-01-01

    Saffron, a bulbous perennial plant belonging to Iridaceae family, is the most expensive cultivated herb that is widely used for industrial and nonindustrial purposes. However, besides its attractive and valuable properties, contact dermatitis due to saffron is an uncommon reported entity. The aims of this study were to determine the clinical pattern patch-testing profile of contact dermatitis in saffron workers and to identify the most common allergens/sensitizers. One hundred ten saffron workers were patch-tested with 39 allergens, which included Indian standard series antigens, plant series antigens, and extracts from different parts of saffron flower. The allergens in Indian standard series accounted for 52.44% of positive reactions. Plant series and different parts of saffron accounted for 47.56% of the positive reactions. Among those patients with positive responses to the supplemental saffron allergens, 83.3% were of present or past relevance. The data observed in the present study confirm that the saffron dermatitis is a distinct clinical entity with characteristic clinical presentation and has a strong significance as an occupational allergen in those handling this plant. Patch testing with different parts of saffron flower has a role to play in finding out the etiological cause.

  20. Methodology of Evaluation of the Impact of Picking Area Location on the Total Costs of Warehouse

    Directory of Open Access Journals (Sweden)

    Apsalons Raitis

    2017-12-01

    Full Text Available The picking system and the layout of the picking area are the key drivers for the evaluation of a warehouse picking cost. There are five variants for organizing the picking process of orders in a warehouse. The choice of a specific variant depends on the total cost of picking. The picking cost is evaluated within an uninterrupted picking process. It means that no stock out occurs in the time period of the picking process. The storing area and the picking area are created as two separate zones for picking quantities of the customer’s orders; the principle of division of orders is observed strictly. Referring to the locations of stock keeping units (SKU, two approaches of the layout of SKU in the picking area can be estimated. The first one is the single picking location for each single SKU, where replenishment is realized in the picking process. The second one - various picking locations for each single SKU, and the replenishment here is realized just only prior to a picking process or after it. The main benefits of the economy of the picking cost as far as these two approaches are concerned are the shortest picking route in the first case and one common replenishment option in the second case.

  1. Mapping the electrical properties of large-area graphene

    DEFF Research Database (Denmark)

    Bøggild, Peter; Mackenzie, David; Whelan, Patrick Rebsdorf

    2017-01-01

    The significant progress in terms of fabricating large-area graphene films for transparent electrodes, barriers, electronics, telecommunication and other applications has not yet been accompanied by efficient methods for characterizing the electrical properties of large-area graphene. While......, and a high measurement effort per device. In this topical review, we provide a comprehensive overview of the issues that need to be addressed by any large-area characterisation method for electrical key performance indicators, with emphasis on electrical uniformity and on how this can be used to provide...... a more accurate analysis of the graphene film. We review and compare three different, but complementary approaches that rely either on fixed contacts (dry laser lithography), movable contacts (micro four point probes) and non-contact (terahertz time-domain spectroscopy) between the probe and the graphene...

  2. Evaluation of Tire/Surfacing/Base Contact Stresses and Texture Depth

    Directory of Open Access Journals (Sweden)

    W.J.vdM. Steyn

    2015-03-01

    Full Text Available Tire rolling resistance has a major impact on vehicle fuel consumption. Rolling resistance is the loss of energy due to the interaction between the tire and the pavement surface. This interaction is a complicated combination of stresses and strains which depend on both tire and pavement related factors. These include vehicle speed, vehicle weight, tire material and type, road camber, tire inflation pressure, pavement surfacing texture etc. In this paper the relationship between pavement surface texture depth and tire/surfacing contact stress and area is investigated. Texture depth and tire/surfacing contact stress were measured for a range of tire inflation pressures on five different pavement surfaces. In the analysis the relationship between texture and the generated contact stresses as well as the contact stress between the surfacing and base layer are presented and discussed, and the anticipated effect of these relationships on the rolling resistance of vehicles on the surfacings, and subsequent vehicle fuel economy discussed.

  3. Contact Thermal Analysis and Wear Simulation of a Brake Block

    Directory of Open Access Journals (Sweden)

    Nándor Békési

    2013-01-01

    Full Text Available The present paper describes an experimental test and a coupled contact-thermal-wear analysis of a railway wheel/brake block system through the braking process. During the test, the friction, the generated heat, and the wear were evaluated. It was found that the contact between the brake block and the wheel occurs in relatively small and slowly moving hot spots, caused by the wear and the thermal effects. A coupled simulation method was developed including numerical frictional contact, transient thermal and incremental wear calculations. In the 3D simulation, the effects of the friction, the thermal expansion, the wear, and the temperature-dependent material properties were also considered. A good agreement was found between the results of the test and the calculations, both for the thermal and wear results. The proposed method is suitable for modelling the slowly oscillating wear caused by the thermal expansions in the contact area.

  4. Contact Resistance Reduction of ZnO Thin Film Transistors (TFTs) with Saw-Shaped Electrode

    KAUST Repository

    Park, Woojin

    2018-05-15

    We report a saw-shaped electrode architecture ZnO thin film transistor (TFT) for effectively increase channel width. Such a saw-shaped electrode has ~2 times longer contact line at the contact metal/ZnO channel junction. We experimentally observed an enhancement in the output drive current by 50% and reduction in the contact resistance by over 50%, when compared to a typical shaped electrode ZnO TFT consuming the same chip area. This performance enhancement is attributed to extension of channel width. This technique can contribute to device performance enhancement and especially reduction in the contact resistance which is a serious challenge.

  5. How pinning and contact angle hysteresis govern quasi-static liquid drop transfer.

    Science.gov (United States)

    Chen, H; Tang, T; Zhao, H; Law, K-Y; Amirfazli, A

    2016-02-21

    This paper presents both experimental and numerical simulations of liquid transfer between two solid surfaces with contact angle hysteresis (CAH). Systematic studies on the role of the advancing contact angle (θa), receding contact angle (θr) and CAH in determining the transfer ratio (volume of the liquid transferred onto the acceptor surface over the total liquid volume) and the maximum adhesion force (Fmax) were performed. The transfer ratio was found to be governed by contact line pinning at the end of the transfer process caused by CAH of surfaces. A map based on θr of the two surfaces was generated to identify the three regimes for liquid transfer: (I) contact line pinning occurs only on the donor surface, (II) contact line pinning occurs on both surfaces, and (III) contact line pinning occurs only on the acceptor surface. With this map, an empirical equation is provided which is able to estimate the transfer ratio by only knowing θr of the two surfaces. The value of Fmax is found to be strongly influenced by the contact line pinning in the early stretching stage. For symmetric liquid bridges between two identical surfaces, Fmax may be determined only by θa, only by θr, or by both θa and θr, depending on the magnitude of the contact angles. For asymmetric bridges, Fmax is found to be affected by the period when contact lines are pinned on both surfaces.

  6. The Arctic: Glacial Refugium or Area of Secondary Contact? Inference from the Population Genetic Structure of the Thick-Billed Murre (Uria lomvia), with Implications for Management.

    Science.gov (United States)

    Tigano, Anna; Damus, Martin; Birt, Tim P; Morris-Pocock, Jamie A; Artukhin, Yuri B; Friesen, Vicki L

    2015-01-01

    Quaternary glaciations affected the distribution of many species. Here, we investigate whether the Arctic represented a glacial refugium during the Last Glacial Maximum or an area of secondary contact following the ice retreat, by analyzing the genetic population structure of the thick-billed murre (Uria lomvia), a seabird that breeds throughout the North Atlantic, North Pacific and Arctic Oceans. The thick-billed murre is a species of socio-economic importance and faces numerous threats including hunting, oil pollution, gill netting, and climate change. We compared variation in the mitochondrial DNA (mtDNA) control region (n = 424), supplemented by 4 microsatellite loci (n = 445), among thick-billed murres sampled throughout their range. MtDNA data indicated that colonies comprise 4 genetically differentiated groups (Φst = 0.11-0.81): 1) Atlantic Ocean plus New Siberian Islands region, 2) Cape Parry, 3) Chukchi Sea, and 4) Pacific Ocean. Microsatellite variation differed between Atlantic and Pacific populations. Otherwise, little substructure was found within either ocean. Atlantic and Pacific populations appear to have been genetically isolated since the last interglacial period and should be considered separate evolutionary significant units for management. The Chukchi Sea and Cape Parry appear to represent areas of secondary contact, rather than arctic refugial populations. © The American Genetic Association 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Cost-of-illness of patients with contact dermatitis in Denmark.

    Science.gov (United States)

    Saetterstrøm, Bjørn; Olsen, Jens; Johansen, Jeanne Duus

    2014-09-01

    Contact dermatitis is a frequent occupational and non-occupational skin disease. To investigate the effects of contact dermatitis on labour market affiliation and societal costs in terms of healthcare costs and production loss. A total of 21 441 patients patch tested either in hospital departments or at dermatological clinics in the period 2004-2009 were included in the study. The analyses were stratified by children (age 0-15 years), occupational contact dermatitis (age 16-65 years), and non-occupational dermatitis (age ≥ 16 years). Controls were selected from a 30% random sample of the population. Individual encrypted data were retrieved on healthcare utilization, socio-demographics, education, labour market affiliation and transfer payments from public registers in Denmark for cases and controls. Attributable healthcare costs for 4 years prior to patch testing (1 year for children) and the year after patch testing were €959 for children, €724 for occupational contact dermatitis, and €1794 for non-occupational dermatitis. Productivity costs for the same period were €10 722 for occupational contact dermatitis and €3074 for non-occupational contact dermatitis. The main findings of this study were that there were statistically significant attributable healthcare costs for both children and adults, and statistically significant productivity loss for adults. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Approaching total absorption at near infrared in a large area monolayer graphene by critical coupling

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yonghao; Chadha, Arvinder; Zhao, Deyin; Shuai, Yichen; Menon, Laxmy; Yang, Hongjun; Zhou, Weidong, E-mail: wzhou@uta.edu [Nanophotonics Lab, Department of Electrical Engineering, University of Texas at Arlington, Arlington, Texas 76019 (United States); Piper, Jessica R.; Fan, Shanhui [Ginzton Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Jia, Yichen; Xia, Fengnian [Department of Electrical Engineering, Yale University, New Haven, Connecticut 06520 (United States); Ma, Zhenqiang [Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2014-11-03

    We demonstrate experimentally close to total absorption in monolayer graphene based on critical coupling with guided resonances in transfer printed photonic crystal Fano resonance filters at near infrared. Measured peak absorptions of 35% and 85% were obtained from cavity coupled monolayer graphene for the structures without and with back reflectors, respectively. These measured values agree very well with the theoretical values predicted with the coupled mode theory based critical coupling design. Such strong light-matter interactions can lead to extremely compact and high performance photonic devices based on large area monolayer graphene and other two–dimensional materials.

  9. Determination of free cyanide and total cyanide concentrations in surface and underground waters in Bogoso and its surrounding areas in Ghana

    Directory of Open Access Journals (Sweden)

    S. Obiri

    2007-08-01

    Full Text Available Concentrations of free cyanide and total cyanide in water samples in Bogoso and its surrounding areas in Ghana have been measured in this study. Concentrations of free cyanide and total cyanide were found to be above the maximum permissible discharge limit of effluent from mining companies into natural waters set by Environmental Protection Agency, Ghana (GEPA. A comparison of the results obtained in this study with permissible levels set by US Environmental Protection Agency and the World Health Organization reveals that surface waters in the study areas are highly polluted with cyanide and it's not safe for human consumptions. This means that, the resident in and around Bogoso are at risk.

  10. Sulfur passivation and contact methods for GaAs nanowire solar cells

    International Nuclear Information System (INIS)

    Tajik, N; Peng, Z; Kuyanov, P; LaPierre, R R

    2011-01-01

    The effect of sulfur passivation on core-shell p-n junction GaAs nanowire (NW) solar cells has been investigated. Devices of two types were investigated, consisting of indium tin oxide contact dots or opaque Au finger electrodes. Lateral carrier transport from the NWs to the contact fingers was achieved via a p-doped GaAs surface conduction layer. NWs between the opaque contact fingers had sidewall surfaces exposed for passivation by sulfur. The relative cell efficiency increased by 19% upon passivation. The contribution of the thin film grown between the NWs to the total cell efficiency was estimated by removing the NWs using a sonication procedure. Mechanisms of carrier transport and photovoltaic effects are discussed on the basis of spatially resolved laser scanning measurements.

  11. Patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil

    2008-01-01

    Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....

  12. Blink patterns and lid-contact times in dry-eye and normal subjects

    Directory of Open Access Journals (Sweden)

    Ousler GW 3rd

    2014-05-01

    Full Text Available George W Ousler 3rd,1 Mark B Abelson,1,2 Patrick R Johnston,1 John Rodriguez,1 Keith Lane,1 Lisa M Smith11Ora, Andover, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USAPurpose: To classify blinks in dry eye and normal subjects into six subtypes, and to define the blink rate and duration within each type of blink, as well as the total lid-contact time/minute.Materials and methods: This was a single-centered, prospective, double-blind study of eleven dry-eye and ten normal subjects. Predefined subjects watched a video while blinks were recorded for 10 minutes. Partial blinks were classified by percentage closure of maximal palpebral fissure opening: 25%, 50%, 75%. Complete blinks were characterized as full (>0 seconds, extended (>0.1 seconds, or superextended (>0.5 seconds. The mean duration of each type of blink was determined and standardized per minute as total lid-contact time.Results: Total blinks observed were 4,990 (1,414 normal, 3,756 dry eye: 1,809 (50.59% partial and 1,767 (49.41% complete blinks among dry-eye subjects versus 741 (52.90% partial and 673 (47.60% complete blinks among normal subjects. Only superextended blinks of ≥0.5-second duration were significantly more frequent in dry-eye subjects than normals (2.3% versus 0.2%, respectively; P=0.023. Total contact time was seven times higher in dry-eye subjects than normals (0.565 versus 0.080 seconds, respectively; P<0.001. Isolating only extended blinks (>0.1 second, the average contact time (seconds was four times longer in dry-eye versus normal subjects (2.459 in dry eye, 0.575 in normals; P=0.003. Isolating only superextended blinks (>0.5 seconds, average contact time was also significantly different (7.134 in dry eye, 1.589 in normals; P<0.001. The contact rate for all full closures was 6.4 times longer in dry-eye (0.045 versus 0.007, P<0.001 than normal subjects.Conclusion: Dry-eye subjects spent 4.5% of a

  13. Electrical contact arrangement for a coating process

    Science.gov (United States)

    Kabagambe, Benjamin; McCamy, James W; Boyd, Donald W

    2013-09-17

    A protective coating is applied to the electrically conductive surface of a reflective coating of a solar mirror by biasing a conductive member having a layer of a malleable electrically conductive material, e.g. a paste, against a portion of the conductive surface while moving an electrodepositable coating composition over the conductive surface. The moving of the electrodepositable coating composition over the conductive surface includes moving the solar mirror through a flow curtain of the electrodepositable coating composition and submerging the solar mirror in a pool of the electrodepositable coating composition. The use of the layer of a malleable electrically conductive material between the conductive member and the conductive surface compensates for irregularities in the conductive surface being contacted during the coating process thereby reducing the current density at the electrical contact area.

  14. Water hammers in direct contact heater systems

    International Nuclear Information System (INIS)

    Uffer, R.

    1983-01-01

    This paper discusses the causes and mitigation or prevention of water hammers occurring in direct contact heaters and their attached lines. These water hammers are generally caused by rapid pressure reductions in the heaters or by water lines not flowing full. Proper design and operating measures can prevent or mitigate water hammer occurrence. Water hammers often do not originate at the areas where damage is noted

  15. The effect of changing the contact surface area between pleural liquid and pleura on the turnover of pleural liquid.

    Science.gov (United States)

    Nakamura, T; Hara, H; Ijima, F; Arai, T; Kira, S

    1984-03-01

    To study the dynamics of pleural liquid, 250 ml of saline labeled with markers were injected into the pleural cavity of anesthetized dogs. For 3 h, liquid volume and concentration of these markers were measured. In a control group of dogs, the turnover rate of pleural liquid was 19.6 +/- 5.6 ml/min and lymphatic flow was 0.58 +/- 0.07 ml/min. In a group of pneumonectomized dogs, the turnover rate and lymphatic flow fell to about one fourth of those in the control group. When the left pulmonary artery was occluded, the turnover rate was halved, but lymphatic flow was not significantly different from that in the control group. These results suggest that the turnover rate of pleural liquid is dependent on the area of contact between pleural liquid and pleura and on the blood flow of the pleura. In addition, it appears that changes in pleural liquid volume are dependent on lymphatic flow.

  16. Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    Science.gov (United States)

    Kern, Andrew M; Anderson, Donald D

    2015-09-18

    Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promising agreement with PTOA development was seen, the inherent complexities of contact FEA limited the numbers of subjects that could be analyzed. Discrete element analysis (DEA) is a simplified methodology for contact stress computation, which idealizes contact surfaces as a bed of independent linear springs. In this study, DEA was explored as an expedited alternative to FEA contact stress exposure computation. DEA was compared to FEA using results from a previously completed validation study of two cadaveric human ankles, as well as a previous study of post-operative contact stress exposure in 11 patients with tibial plafond fracture. DEA-computed maximum contact stresses were within 19% of those experimentally measured, with 90% of the contact area having computed contact stress values within 1MPa of those measured. In the 11 fractured ankles, maximum contact stress and contact area differences between DEA and FEA were 0.85 ± 0.64 MPa and 22.5 ± 11.5mm(2). As a predictive measure for PTOA development, both DEA and FEA had 100% concordance with presence of OA (KL grade ≥ 2) and >95% concordance with KL grade at 2 years. These results support DEA as a reasonable alternative to FEA for computing contact stress exposures following surgical reduction of a tibial plafond fracture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Acanthamoeba keratitis in Scotland: risk factors for contact lens wearers.

    Science.gov (United States)

    Seal, D V; Kirkness, C M; Bennett, H G; Peterson, M

    1999-01-01

    To investigate risk factors for Acanthamoeba keratitis amongst contact lens wearers in Scotland. Patients with Acanthamoeba keratitis in the Scottish study, all of whom wore contact lenses, were compared with 46 healthy asymptomatic contact lens-wearing controls. They were all visited at home for contact lens and environmental microbiological sampling. In addition, all 288 optical practices in the West of Scotland were polled for contact lens types and disinfecting solutions sold in 1995, and a sample, each of whom fitted more than 500 contact lenses per year, were polled for a second time. Independently, a poll was commissioned by the Eyecare Information Service in July/August 1995 to estimate the numbers of contact lens wearers in Scotland and the UK. Industry was polled for numbers of each contact lens disinfecting regimen sold in Scotland in 1995. West of Scotland, UK. All contact lens wearers among the 3 million population of the West of Scotland Health Board Areas. Risk factors for Acanthamoeba infection and recommendations for its prevention. When Acanthamoeba infection occurred, patients' home water systems were frequently (54%) found to be colonised by this amoeba. Patients more frequently washed their storage cases in tap water than controls (Pmethods (chlorine tablets or no disinfection). However further investigation showed that these methods were associated with an increased probability of rinsing the storage case in tap water, so that these two behaviours are confounded in the group studied. Failure to disinfect contact lenses, non-compliant use of chlorine tablets and/or introduction of tap water rinsing of storage cases were associated with increased risk of Acanthamoeba infection. New multipurpose solutions and hydrogen peroxide gave the lowest risk of Acanthamoeba infection, with no statistically significant difference between them. Ionic high-water content (FDA group 4) contact lenses were at increased risk of being associated with Acanthamoeba

  18. Submicron three-dimensional structures fabricated by reverse contact UV nanoimprint lithography

    DEFF Research Database (Denmark)

    Kehagias, N.; Reboud, Vincent; Chansin, G.

    2006-01-01

    The fabrication of a three-dimensional multilayered nanostructure is demonstrated with a newly developed nanofabrication technique, namely, reverse contact ultraviolet nanoimprint lithography. This technique is a combination of reverse nanoimprint lithography and contact ultraviolet lithography....... In this process, a UV cross-linkable polymer and a thermoplastic polymer are spin coated onto a patterned hybrid metal-quartz stamp. These thin polymer films are then transferred from the stamp to the substrate by contact at a suitable temperature and pressure. The whole assembly is then exposed to UV light....... After separation of the stamp and the substrate, the unexposed polymer areas are rinsed away with acetone leaving behind the negative features of the original stamp with no residual layer....

  19. Implementation and applications of a finite-element model for the contact between rough surfaces

    DEFF Research Database (Denmark)

    Poulios, Konstantinos; Klit, Peder

    2013-01-01

    Due to the rough nature of real mechanical surfaces, the contact between elastic bodies occurs at several size-scales. Statistical and fractal contact models can take a wide range of roughness wavelengths into account, without additional computational cost. However, deterministic models are more ...... in the examples. Among the presented results one can find the distribution of the contact pressure at the interface and diagrams of the real area of contact as a function of the nominal contact pressure. © 2013 Elsevier B.V.......Due to the rough nature of real mechanical surfaces, the contact between elastic bodies occurs at several size-scales. Statistical and fractal contact models can take a wide range of roughness wavelengths into account, without additional computational cost. However, deterministic models are more...... straightforward to understand and easier to extend to more complex cases like contacting bodies that demonstrate elasto-plastic behavior. This paper presents a finite-element model for studying the frictionless contact between nominally flat rough surfaces. Apart from a description of the model implementation...

  20. Radiological implications of contact maintenance: Impacts on facility design

    International Nuclear Information System (INIS)

    Brown, R.C.

    1994-01-01

    The purpose of this document is to provide an initial, rough order of magnitude, evaluation of the relationship between the concentrations of selected radionuclides in process streams of a chemical process plant and the required degree of protective features for plant operations personnel. The evaluation provided in this document specifies ''trigger level'' concentrations of 90 Sr, 137 Cs, and transuranics (TRU) for ''contact maintenance'' activities. Concentrations above the ''trigger levels'' can be accommodated provided offsetting design features are incorporated (e.g., improved shielding partial to total confinement, etc.). This information will assist in defining the degree of reduction of concentrations of radionuclides required for the feed used in a low-level liquid waste processing plant to utilize a contact maintenance design concept. Offsetting design features that influence maintenance personnel exposures in a contact maintenance situation are identified. All concentrations are expressed in terms of actual process fluids before any flushing and decontamination steps