WorldWideScience

Sample records for total cod removal

  1. Optimizing TOC and COD removal for the biodiesel wastewater by electrocoagulation

    Science.gov (United States)

    Tanattı, N. Pınar; Şengil, İ. Ayhan; Özdemir, Abdil

    2018-05-01

    In this study, the chemical oxygen demand (COD) and the total organic carbon content (TOC) in biodiesel wastewater iron and aluminum electrodes arranged in a bipolar position. In the EC of the biodiesel wastewater, the effects of the supporting electrolyte, initial pH, electrolysis time and current density were examined. The results showed that the majority of the pollutants in the biodiesel wastewater were effectively removed when the iron or aluminum electrodes were used as a sacrificial anode. The highest COD and TOC removal efficiencies were successfully obtained with the iron electrode. COD removal efficiencies are 91.74 and 90.94% for iron and aluminum electrode, respectively. In the same way, TOC removal efficiencies were obtained as 91.79 and 91.98% for the iron and aluminum electrodes, respectively, at initial pH of 6, the current density of 0.3226 mA/cm2, NaCl concentration 1 g/L and 1 min of operating time.

  2. COD and colour removal from molasses spent wash using activated ...

    African Journals Online (AJOL)

    The removal of COD and colour from a melanoidin solution with this activated carbon was carried out using an experimental design taking 4 factors into account. These were adsorbent dose, contact time, pH and initial COD concentration, with removal of COD and colour as response variables. COD reduction was ...

  3. Removal of COD from laundry wastewater by electrocoagulation/electroflotation

    International Nuclear Information System (INIS)

    Wang, C.-T.; Chou, W.-L.; Kuo, Y.-M.

    2009-01-01

    The removal efficiency of COD in the treatment of simulated laundry wastewater using electrocoagulation/electroflotation technology is described. The experimental results showed that the removal efficiency was better, reaching to about 62%, when applying ultrasound to the electrocoagulation cell. The solution pH approached neutrality in all experimental runs. The optimal removal efficiency of COD was obtained by using the applied voltage of 5 V when considering the energy efficiency and the acceptable removal efficiency simultaneously. The Cl - concentration of less than 2500 ppm had a positive effect on the removal efficiency. The performance of the monopolar connection of electrodes was better than that of the bipolar connection in this work. In addition, the removal efficiency of using Al electrodes was higher in comparison with using Fe electrodes in the study. The highest COD removal amount per joule was found to be 999 mg dm -3 kW h -1 while using two Al electrodes, although the removal efficiency increased with the number of Al plates

  4. COD removal characteristics in air-cathode microbial fuel cells

    KAUST Repository

    Zhang, Xiaoyuan

    2015-01-01

    © 2014 Elsevier Ltd. Exoelectrogenic microorganisms in microbial fuel cells (MFCs) compete with other microorganisms for substrate. In order to understand how this affects removal rates, current generation, and coulombic efficiencies (CEs), substrate removal rates were compared in MFCs fed a single, readily biodegradable compound (acetate) or domestic wastewater (WW). Removal rates based on initial test conditions fit first-order kinetics, but rate constants varied with circuit resistance. With filtered WW (100Ω), the rate constant was 0.18h- 1, which was higher than acetate or filtered WW with an open circuit (0.10h- 1), but CEs were much lower (15-24%) than acetate. With raw WW (100Ω), COD removal proceeded in two stages: a fast removal stage with high current production, followed by a slower removal with little current. While using MFCs increased COD removal rate due to current generation, secondary processes will be needed to reduce COD to levels suitable for discharge.

  5. Potential of hydrolysis of particulate COD in extended anaerobic conditions to enhance biological phosphorous removal.

    Science.gov (United States)

    Jabari, P; Yuan, Q; Oleszkiewicz, J A

    2016-11-01

    The effect of anaerobic hydrolysis of particulate COD (pCOD) on biological phosphorous removal in extended anaerobic condition was investigated through (i) sequencing batch reactors (SBR)s with anaerobic hydraulic retention time (HRT) of 0.8, 2, and 4 h; (ii) batch tests using biomass from a full scale biological nutrient removal (BNR) plant; and (iii) activated sludge modeling (BioWin 4.1 simulation). The results from long-term SBRs operation showed that phosphorus removal was correlated to the ratio of filtered COD (FCOD) to total phosphorus (TP) in the influent. Under conditions with low FCOD/TP ratio (average of 20) in the influent, extending anaerobic HRT to 4 h in the presence of pCOD did not significantly improve overall phosphorous removal. During the period with high FCOD/TP ratio (average of 37) in the influent, all SBRs removed phosphorous completely, and the long anaerobic HRT did not have negative effect on overall phosphorous removal. The batch tests also showed that pCOD at different concentration during 4 h test did not affect the rate of anaerobic phosphorus release. The rate of anaerobic hydrolysis of pCOD was significantly low and extending the anaerobic HRT was ineffective. The simulation (BioWin 4.1) of SBRs with low influent FCOD/TP ratio showed that the default kinetics of anaerobic hydrolysis in ASM2d overestimated phosphorous removal in the SBRs (high anaerobic hydrolysis of pCOD). The default anaerobic hydrolysis rate in BioWin 4.1 (ten times lower) could produce similar phosphorous removal to that in the experiment. Results showed that the current kinetics of anaerobic hydrolysis in ASM2d could lead to considerable error in predicting phosphorus removal in processes with extended anaerobic HRT. Biotechnol. Bioeng. 2016;113: 2377-2385. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Long term operation of continuous-flow system with enhanced biological phosphorus removal granules at different COD loading.

    Science.gov (United States)

    Li, Dong; Lv, Yufeng; Zeng, Huiping; Zhang, Jie

    2016-09-01

    In this study, a continuous-flow system with enhanced biological phosphorus removal (EBPR) granules was operated at different COD concentrations (200, 300 and 400mgL(-)(1)) to investigate the effect of COD loading on this system. The results showed that when the COD concentration in influent was increased to 400mgL(-)(1), the anaerobic COD removal efficiency and total phosphorus removal efficiency reduced obviously and the settling ability of granules deteriorated due to the proliferation of filamentous bacteria. Moreover, high COD loading inhibited the EPS secretion and destroyed the stability of granules. Results of high-through pyrosequencing indicated that filamentous bacteria had a competitive advantage over polyphosphate-accumulating organisms (PAOs) at high COD loading. The performance of system, settling ability of granules and proportion of PAOs gradually recovered to the initial level after the COD concentration was reduced to 200mgL(-)(1) on day 81. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Removal of COD from laundry wastewater by electrocoagulation/electroflotation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C.-T. [Department of Safety Health and Environmental Engineering, Chung Hwa University of Medical Technology, Tainan County, Hsien 717, Taiwan (China)], E-mail: ctwwang@mail.hwai.edu.tw; Chou, W.-L. [Department of Safety Health and Environmental Engineering and Institute of Occupational Safety and Hazard Prevention, HungKuang University, Sha-Lu, Taichung 433, Taiwan (China); Kuo, Y.-M. [Department of Safety Health and Environmental Engineering, Chung Hwa University of Medical Technology, Tainan County, Hsien 717, Taiwan (China)

    2009-05-15

    The removal efficiency of COD in the treatment of simulated laundry wastewater using electrocoagulation/electroflotation technology is described. The experimental results showed that the removal efficiency was better, reaching to about 62%, when applying ultrasound to the electrocoagulation cell. The solution pH approached neutrality in all experimental runs. The optimal removal efficiency of COD was obtained by using the applied voltage of 5 V when considering the energy efficiency and the acceptable removal efficiency simultaneously. The Cl{sup -} concentration of less than 2500 ppm had a positive effect on the removal efficiency. The performance of the monopolar connection of electrodes was better than that of the bipolar connection in this work. In addition, the removal efficiency of using Al electrodes was higher in comparison with using Fe electrodes in the study. The highest COD removal amount per joule was found to be 999 mg dm{sup -3} kW h{sup -1} while using two Al electrodes, although the removal efficiency increased with the number of Al plates.

  8. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation

    International Nuclear Information System (INIS)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-01-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (±0.2) and a total COD of 12,100 (±910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32 ± 2 deg. C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m 3 day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe 2+ and H 2 O 2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H 2 O 2 and Fe 2+ dosages, and the ratio of H 2 O 2 /Fe 2+ . Preliminary tests conducted with the dosages of 100 mg Fe 2+ /L and 200 mg H 2 O 2 /L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe 2+ and H 2 O 2 were investigated. Under the condition of 400 mg Fe 2+ /L and 200 mg H 2 O 2 /L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe 2+ /L and 1200 mg H 2 O 2 /L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit

  9. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation.

    Science.gov (United States)

    Yetilmezsoy, Kaan; Sakar, Suleyman

    2008-03-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (+/-0.2) and a total COD of 12,100 (+/-910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32+/-2 degrees C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m3day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe2+ and H2O2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H2O2 and Fe2+ dosages, and the ratio of H2O2/Fe2+. Preliminary tests conducted with the dosages of 100 mg Fe2+/L and 200 mg H2O2/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe2+ and H2O2 were investigated. Under the condition of 400 mg Fe2+/L and 200 mg H2O2/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe2+/L and 1200 mg H2O2/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit.

  10. Comparison of COD removal from pharmaceutical wastewater by electrocoagulation, photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes.

    Science.gov (United States)

    Farhadi, Sajjad; Aminzadeh, Behnoush; Torabian, Ali; Khatibikamal, Vahid; Alizadeh Fard, Mohammad

    2012-06-15

    This work makes a comparison between electrocoagulation (EC), photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes to investigate the removal of chemical oxygen demand (COD) from pharmaceutical wastewater. The effects of operational parameters such as initial pH, current density, applied voltage, amount of hydrogen peroxide and electrolysis time on COD removal efficiency were investigated and the optimum operating range for each of these operating variables was experimentally determined. In electrocoagulation process, the optimum values of pH and voltage were determined to be 7 and 40 V, respectively. Desired pH and hydrogen peroxide concentration in the Fenton-based processes were found to be 3 and 300 mg/L, respectively. The amounts of COD, pH, electrical conductivity, temperature and total dissolved solids (TDS) were on-line monitored. Results indicated that under the optimum operating range for each process, the COD removal efficiency was in order of peroxi-electrocoagulation > peroxi-photoelectrocoagulation > photoelectrocoagulation>electrocoagulation. Finally, a kinetic study was carried out using the linear pseudo-second-order model and results showed that the pseudo-second-order equation provided the best correlation for the COD removal rate. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Treatment of coal gasification wastewater by a two-continuous UASB system with step-feed for COD and phenols removal

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W.; Han, H.J.; Yuan, M.; Li, H.Q.; Fang, F.; Wang, K. [Harbin Institute of Technology, Harbin (China)

    2011-05-15

    A two-continuous mesophilic (37 {+-} 2{sup o}C) UASB system with step-feed was investigated as an attractive optimization strategy for enhancing COD and total phenols removal of the system and improving aerobic biodegradability of real coal gasification wastewater. Through the step-feed period, the maximum removal efficiencies of COD and total phenols reached 55-60% and 58-63% respectively in the system, at an influent flow distribution ratio of 0.2 and influent COD concentration of 2500 mg/L; the corresponding efficiencies were at low levels of 45-50% and 43-50% respectively at total HRT of 48 h during the single-feed period. The maximum specific methanogenic activity and substrate utilization rate were 592 {+-} 16 mg COD-CH{sub 4}/(gVSS d) and 89 {+-} 12 mg phenol/(gVSS d) during the step-feed operation. After the anaerobic digestion with step-feed, the aerobic effluent COD concentration decreased from 270 {+-} 9 to 215 {+-} 10 mg/L. The results suggested that step-feed enhanced the degradation of refractory organics in the second reactor.

  12. Comparison of COD removal from pharmaceutical wastewater by electrocoagulation, photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes

    International Nuclear Information System (INIS)

    Farhadi, Sajjad; Aminzadeh, Behnoush; Torabian, Ali; Khatibikamal, Vahid; Alizadeh Fard, Mohammad

    2012-01-01

    Highlights: ► Hydrogen peroxide improves the performance of electrocoagulation process. ► UV light can be effective on the performance on peroxi-electrocoagulation and electrocoagulation processes. ► The optimal amount of hydrogen peroxide for peroxi-electrocoagulation process for COD removal from pharmaceutical wastewater is 300 mg/L. ► The optimal values of pH for electrocoagulation and peroxi-electrocoagulation are 7 and 3, respectively. - Abstract: This work makes a comparison between electrocoagulation (EC), photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes to investigate the removal of chemical oxygen demand (COD) from pharmaceutical wastewater. The effects of operational parameters such as initial pH, current density, applied voltage, amount of hydrogen peroxide and electrolysis time on COD removal efficiency were investigated and the optimum operating range for each of these operating variables was experimentally determined. In electrocoagulation process, the optimum values of pH and voltage were determined to be 7 and 40 V, respectively. Desired pH and hydrogen peroxide concentration in the Fenton-based processes were found to be 3 and 300 mg/L, respectively. The amounts of COD, pH, electrical conductivity, temperature and total dissolved solids (TDS) were on-line monitored. Results indicated that under the optimum operating range for each process, the COD removal efficiency was in order of peroxi-electrocoagulation > peroxi-photoelectrocoagulation > photoelectrocoagulation > electrocoagulation. Finally, a kinetic study was carried out using the linear pseudo-second-order model and results showed that the pseudo-second-order equation provided the best correlation for the COD removal rate.

  13. Comparison of COD removal from pharmaceutical wastewater by electrocoagulation, photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes

    Energy Technology Data Exchange (ETDEWEB)

    Farhadi, Sajjad, E-mail: sajjadfarhadi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran (Iran, Islamic Republic of); Aminzadeh, Behnoush, E-mail: bamin@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran (Iran, Islamic Republic of); Torabian, Ali, E-mail: atorabi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran (Iran, Islamic Republic of); Khatibikamal, Vahid, E-mail: vahidkhatibi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran (Iran, Islamic Republic of); Alizadeh Fard, Mohammad, E-mail: malizadeh1987@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran (Iran, Islamic Republic of)

    2012-06-15

    Highlights: Black-Right-Pointing-Pointer Hydrogen peroxide improves the performance of electrocoagulation process. Black-Right-Pointing-Pointer UV light can be effective on the performance on peroxi-electrocoagulation and electrocoagulation processes. Black-Right-Pointing-Pointer The optimal amount of hydrogen peroxide for peroxi-electrocoagulation process for COD removal from pharmaceutical wastewater is 300 mg/L. Black-Right-Pointing-Pointer The optimal values of pH for electrocoagulation and peroxi-electrocoagulation are 7 and 3, respectively. - Abstract: This work makes a comparison between electrocoagulation (EC), photoelectrocoagulation, peroxi-electrocoagulation and peroxi-photoelectrocoagulation processes to investigate the removal of chemical oxygen demand (COD) from pharmaceutical wastewater. The effects of operational parameters such as initial pH, current density, applied voltage, amount of hydrogen peroxide and electrolysis time on COD removal efficiency were investigated and the optimum operating range for each of these operating variables was experimentally determined. In electrocoagulation process, the optimum values of pH and voltage were determined to be 7 and 40 V, respectively. Desired pH and hydrogen peroxide concentration in the Fenton-based processes were found to be 3 and 300 mg/L, respectively. The amounts of COD, pH, electrical conductivity, temperature and total dissolved solids (TDS) were on-line monitored. Results indicated that under the optimum operating range for each process, the COD removal efficiency was in order of peroxi-electrocoagulation > peroxi-photoelectrocoagulation > photoelectrocoagulation > electrocoagulation. Finally, a kinetic study was carried out using the linear pseudo-second-order model and results showed that the pseudo-second-order equation provided the best correlation for the COD removal rate.

  14. Improvement of COD and color removal from UASB treated poultry manure wastewater using Fenton's oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Yetilmezsoy, Kaan [Department of Environmental Engineering, Yildiz Technical University, 34349 Yildiz, Besiktas, Istanbul (Turkey)], E-mail: yetilmez@yildiz.edu.tr; Sakar, Suleyman [Department of Environmental Engineering, Yildiz Technical University, 34349 Yildiz, Besiktas, Istanbul (Turkey)

    2008-03-01

    The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 ({+-}0.2) and a total COD of 12,100 ({+-}910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32 {+-} 2 deg. C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m{sup 3} day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe{sup 2+} and H{sub 2}O{sub 2} solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H{sub 2}O{sub 2} and Fe{sup 2+} dosages, and the ratio of H{sub 2}O{sub 2}/Fe{sup 2+}. Preliminary tests conducted with the dosages of 100 mg Fe{sup 2+}/L and 200 mg H{sub 2}O{sub 2}/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe{sup 2+} and H{sub 2}O{sub 2} were investigated. Under the condition of 400 mg Fe{sup 2+}/L and 200 mg H{sub 2}O{sub 2}/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe{sup 2+}/L and 1200 mg H{sub 2}O{sub 2}/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a

  15. Particulate COD balance of particulate cod in eletrocuagulation/flotation reactor treating tannery effluent

    Directory of Open Access Journals (Sweden)

    Rodrigo Babora Borri

    2012-04-01

    Full Text Available Mass balance or particulate organic matter was studied in terms of COD, by means of electrocoagulation/flotation (ECF reactor treating tannery effluent. Reactor was operated in fill and draw (batch mode. Operating in hydraulic residence time of 65 minutes, ECF reactor reached 55 % COD removal. Although volatile solids were also removed from liquid phase (removal of 40%, fixed solids concentration, and hence total solids concentration, showed to be higher in withdrawn effluent than in ECF’s influent. This was assigned to NaCl added in order to enhance conductivity in wastewater.

  16. Performance of Anaerobic Baffled Reactor with Three Compartments in Removal of COD of Wastewater of Chilly Sauce

    Directory of Open Access Journals (Sweden)

    Sumantri Indro

    2018-01-01

    Full Text Available The objective in this study is to examine the performance of each compartment of the number of compartments of anaerobic baffled reactor (ABR to the COD removal of the chilly sauce wastewater. Three-compartments of ABR were conducted in this experiment with the total volume of 60 l. ABR is very suitable for processing waste water with high content of COD. Wastewater conducted in this research is a degradable chilly sauce synthetic and high content of organic compounds. While the COD parameter is the main parameter to indicate the achievement of wastewater treatment plant. Stepwise in the research starting with the preparation of raw materials such as sample preparation of synthetic wastewater and preparation of activated sludge. Variable used is the time digestion in the ABR, sludge volume (50% and 70%, and initial COD concentrations (6000 – 14000 mg/L. The response is observed up to 7 days process. For a load of organic compounds, the first compartment has high degree of decomposition of organic compounds than 2nd and 3rd, it is shown that the COD removal the second and third compartment increase insignificantly compare the first compartment. As for the different height of the activated sludge indicated that for organic load of of 6170 mg/L up to 14265 mg/L, the first compartment has removal efficiency 79-73%, in the second compartment is 81-75%, 81-77% and third compartment.

  17. COD removal from pulp and paper effluents by Advanced Oxidation Processes (AOP); COD:n vaehentaeminen aop-menetelmaellae metsaeteollisuuden jaetevesistae - EKY 04

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, K.; Wikberg, H. [Kemira Chemicals Oy, Vaasa (Finland)

    1998-12-31

    The aim of this project is to develop a process where COD from pulp and paper industry can be removed by an AOP process. AOP is a process utilizing the oxidation power of the hydroxyl radical, which can be produced in many different ways. Compared to evaporation and membrane techniques, the benefits of this process are lack of condense, concentrate and sludge. It is a very simple process, based on adjusting the COD removal by means of hydrogen peroxide dosage. The study focuses on using heterogeneous catalyst together with hydrogen peroxide to produce hydroxyl radicals in order to remove COD at low temperatures (< 100 deg C) and normal pressures. The project started by screening catalysts able to perform this task in laboratory scale. Later on pilot scale equipment will be constructed for use in pulp and paper mill trials. The project will be carried out during 1997-1999. The study started by screening the possibilities of different catalysts together with hydrogen peroxide to remove phenols from a model water. Sofar, about hundred catalysts have been screened. These tests show that many of the heterogeneous catalysts are working, but most of them have actually dissolved in the water and `translated` to homogenous catalysts. This means that they cannot be used in this project. A few catalysts have been found to meet the targets for synthetic phenol waters. Next step will be to test these catalysts on actual water samples from pulp and paper mills, and after that a pilot and full-scale trial will be planned. In these trials we will find out which mill streams are possible to treat, and the cost/performances of a system totally based on the catalyst in use. Also, measurements of catalyst leaching and clogging will be made during these tests. The last test series is planned to be a full-scale trial. (orig.)

  18. COD removal from pulp and paper effluents by Advanced Oxidation Processes (AOP); COD:n vaehentaeminen aop-menetelmaellae metsaeteollisuuden jaetevesistae - EKY 04

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, K; Wikberg, H [Kemira Chemicals Oy, Vaasa (Finland)

    1999-12-31

    The aim of this project is to develop a process where COD from pulp and paper industry can be removed by an AOP process. AOP is a process utilizing the oxidation power of the hydroxyl radical, which can be produced in many different ways. Compared to evaporation and membrane techniques, the benefits of this process are lack of condense, concentrate and sludge. It is a very simple process, based on adjusting the COD removal by means of hydrogen peroxide dosage. The study focuses on using heterogeneous catalyst together with hydrogen peroxide to produce hydroxyl radicals in order to remove COD at low temperatures (< 100 deg C) and normal pressures. The project started by screening catalysts able to perform this task in laboratory scale. Later on pilot scale equipment will be constructed for use in pulp and paper mill trials. The project will be carried out during 1997-1999. The study started by screening the possibilities of different catalysts together with hydrogen peroxide to remove phenols from a model water. Sofar, about hundred catalysts have been screened. These tests show that many of the heterogeneous catalysts are working, but most of them have actually dissolved in the water and `translated` to homogenous catalysts. This means that they cannot be used in this project. A few catalysts have been found to meet the targets for synthetic phenol waters. Next step will be to test these catalysts on actual water samples from pulp and paper mills, and after that a pilot and full-scale trial will be planned. In these trials we will find out which mill streams are possible to treat, and the cost/performances of a system totally based on the catalyst in use. Also, measurements of catalyst leaching and clogging will be made during these tests. The last test series is planned to be a full-scale trial. (orig.)

  19. Removal of COD and turbidity to improve wastewater quality using electrocoagulation technique

    International Nuclear Information System (INIS)

    Mohd Faiqun Niam; Fadil Othman; Johan Sohaili; Zulfa Fauzia

    2007-01-01

    Electrocoagulation (EC) is becoming a popular process to be used for wastewater treatment. The removal of COD and turbidity from wastewater by EC using iron (Fe) electrode material was investigated in this paper. Several working parameters, such as pH, current density, and operating time were studied in an attempt to achieve a higher removal capacity. Wastewater sample was made from milk powder with initial COD of 1140 mgL -1 and turbidity of 491 NTU. Current density was varied from 3.51 to 5.62 mA cm -2 , and operating time of between 30 and 50 minutes. The results show that the effluent wastewater was very clear and its quality exceeded the direct discharge standard. The removal efficiencies of COD and turbidity were high, being more than 65 % and 95 %. In addition, the experimental results also show that the electrocoagulation can neutralize pH of wastewater. (author)

  20. Simultaneous removal of AOX and COD from real recycled paper wastewater using GAC-SBBR.

    Science.gov (United States)

    Osman, Wan Hasnidah Wan; Abdullah, Siti Rozaimah Sheikh; Mohamad, Abu Bakar; Kadhum, Abdul Amir H; Rahman, Rakmi Abd

    2013-05-30

    A lab-scale granular activated carbon sequencing batch biofilm reactor (GAC-SBBR), a combined adsorption and biological process, was developed to treat real wastewater from a recycled paper mill. In this study, one-consortia of mixed culture (4000-5000 mg/L) originating from recycled paper mill activated sludge from Kajang, Malaysia was acclimatized. The GAC-SBBR was fed with real wastewater taken from the same recycled paper mill, which had a high concentration of chemical oxygen demand (COD) and adsorbable organic halides (AOX). The operational duration of the GAC-SBBR was adjusted from 48 h to 24, 12 and finally 8 h to evaluate the effect of the hydraulic retention time (HRT) on the simultaneous removal of COD and AOX. The COD and AOX removals were in the range of 53-92% and 26-99%, respectively. From this study, it was observed that the longest HRT (48 h) yielded a high removal of COD and AOX, at 92% and 99%, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Removal of colour and COD from wastewater containing acid blue 22 by electrochemical oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Panizza, Marco [Dipartimento di Ingegneria Chimica e di Processo ' G.B. Bonino' , Universita degli Studi di Genova, p.le J.F. Kennedy 1, 16129 Genova (Italy)], E-mail: marco.panizza@unige.it; Cerisola, Giacomo [Dipartimento di Ingegneria Chimica e di Processo ' G.B. Bonino' , Universita degli Studi di Genova, p.le J.F. Kennedy 1, 16129 Genova (Italy)

    2008-05-01

    Electrochemical oxidation of synthetic wastewater containing acid blue 22 on a boron-doped diamond electrode (BDD) was studied, using cyclic voltammetry and bulk electrolysis. The influence of current density, dye concentration, flow rate, and temperature was investigated, in order to find the best conditions for COD and colour removal. It was found that, during oxidation, a polymeric film, causing BDD deactivation, was formed in the potential region of water stability, and that it was removed by anodic polarisation at high potentials in the region of O{sub 2} evolution. Bulk electrolysis results showed that the electrochemical process was suitable for completely removing COD and effectively decolourising wastewaters, due to the production of hydroxyl radicals on the diamond surface. In particular, under optimal experimental conditions of flow rates (i.e. 300 dm{sup 3} h{sup -1}) and current density (i.e. 20 mA cm{sup -2}), 97% of COD was removed in 12 h electrolysis, with 70 kWh m{sup -3}energy consumption.

  2. Removal of colour and COD from wastewater containing acid blue 22 by electrochemical oxidation

    International Nuclear Information System (INIS)

    Panizza, Marco; Cerisola, Giacomo

    2008-01-01

    Electrochemical oxidation of synthetic wastewater containing acid blue 22 on a boron-doped diamond electrode (BDD) was studied, using cyclic voltammetry and bulk electrolysis. The influence of current density, dye concentration, flow rate, and temperature was investigated, in order to find the best conditions for COD and colour removal. It was found that, during oxidation, a polymeric film, causing BDD deactivation, was formed in the potential region of water stability, and that it was removed by anodic polarisation at high potentials in the region of O 2 evolution. Bulk electrolysis results showed that the electrochemical process was suitable for completely removing COD and effectively decolourising wastewaters, due to the production of hydroxyl radicals on the diamond surface. In particular, under optimal experimental conditions of flow rates (i.e. 300 dm 3 h -1 ) and current density (i.e. 20 mA cm -2 ), 97% of COD was removed in 12 h electrolysis, with 70 kWh m -3 energy consumption

  3. Hierarchical eco-restoration: A systematical approach to removal of COD and dissolved nutrients from an intensive agricultural area

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yonghong, E-mail: yhwu@issas.ac.c [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, 71 Beijing East Road, Nanjing 210008 (China); Graduate Schools, Chinese Academy of Sciences, Beijing 100049 (China); Hu Zhengyi [Graduate Schools, Chinese Academy of Sciences, Beijing 100049 (China); Yang Linzhang, E-mail: lzyang@issas.ac.c [State Key Laboratory of Soil and Sustainable Agriculture, Institute of Soil Science, Chinese Academy of Sciences, 71 Beijing East Road, Nanjing 210008 (China)

    2010-10-15

    A systematical approach based on hierarchical eco-restoration system for the simultaneous removal of COD and dissolved nutrients was proposed and applied in a complex residential-cropland area in Kunming, China from August 2006 to August 2008, where the self-purifying capacity of the agricultural ecosystem had been lost. The system includes four main parts: (1) fertilizer management and agricultural structure optimization, (2) nutrients reuse, (3) wastewater treatment, and (4) catchment restoration. The results showed that the average removal efficiencies were 90% for COD, 93% for ammonia, 94% for nitrate and 71% for total dissolved phosphorus (TDP) when the hierarchical eco-restoration agricultural system was in a relatively steady-state condition. The emergence of 14 species of macrophytes and 4 species of zoobenthos indicated that the growth conditions for the plankton were improved. The results demonstrated that this promising and environmentally benign hierarchical eco-restoration system could decrease the output of nutrients and reduce downstream eutrophication risk. - A systematical approach based on hierarchical eco-restoration system has proven highly effective for simultaneously removing COD and dissolved nutrients, decreasing the output of nutrients, and reducing the eutrophic risk of downstream surface waters.

  4. Hierarchical eco-restoration: A systematical approach to removal of COD and dissolved nutrients from an intensive agricultural area

    International Nuclear Information System (INIS)

    Wu Yonghong; Hu Zhengyi; Yang Linzhang

    2010-01-01

    A systematical approach based on hierarchical eco-restoration system for the simultaneous removal of COD and dissolved nutrients was proposed and applied in a complex residential-cropland area in Kunming, China from August 2006 to August 2008, where the self-purifying capacity of the agricultural ecosystem had been lost. The system includes four main parts: (1) fertilizer management and agricultural structure optimization, (2) nutrients reuse, (3) wastewater treatment, and (4) catchment restoration. The results showed that the average removal efficiencies were 90% for COD, 93% for ammonia, 94% for nitrate and 71% for total dissolved phosphorus (TDP) when the hierarchical eco-restoration agricultural system was in a relatively steady-state condition. The emergence of 14 species of macrophytes and 4 species of zoobenthos indicated that the growth conditions for the plankton were improved. The results demonstrated that this promising and environmentally benign hierarchical eco-restoration system could decrease the output of nutrients and reduce downstream eutrophication risk. - A systematical approach based on hierarchical eco-restoration system has proven highly effective for simultaneously removing COD and dissolved nutrients, decreasing the output of nutrients, and reducing the eutrophic risk of downstream surface waters.

  5. The effect of pH and operation mode for COD removal of slaughterhouse wastewater with Anaerobic Batch Reactor (ABR

    Directory of Open Access Journals (Sweden)

    Maria Octoviane Dyan

    2015-01-01

    Full Text Available Disposal of industrial wastes in large quantities was not in accordance with today's standards of waste into environmental issues that must be overcome with proper treatment. Similarly, the abattoir wastewater that contains too high organic compounds and suspended solids. The amount of liquid waste disposal Slaughterhouse (SW with high volume also causes pollution. The research aim to resolve this problem by lowering the levels of BOD-COD to comply with effluent quality standard. Anaerobic process is the right process for slaughterhouse wastewater treatment because of high content of organic compounds that can be utilized by anaerobic bacteria as a growth medium. Some research has been conducted among abattoir wastewater treatment using anaerobic reactors such as ABR, UASB and ASBR. Our research focuses on the search for the optimum results decline effluent COD levels to match the quality standards limbah and cow rumen fluid with biodigester ABR (Anaerobic Batch Reactor. The variables used were PH of 6, 7, and 8, as well as the concentration ratio of COD: N is 400:7; 450:7, and 500:7. COD value is set by the addition of N derived from urea [CO(NH2 2]. COD levels will be measured daily by water displacement technique. The research’s result for 20 days seen that optimum PH for biogas production was PH 7,719 ml. The optimum PH for COD removal is PH 6, 72.39 %. The operation mode COD:N for biogas production and COD removal is 500:7, with the production value is 601 ml and COD removal value is 63.85 %. The research’s conclusion, the PH optimum for biogas production was PH 7, then the optimum PH for COD removal is PH 6. The optimum operation mode COD:N for biogas production and COD removal was 500:7

  6. Optimizing removal of cod from water by catalytic ozonation of cephalexin using response surface methodology

    International Nuclear Information System (INIS)

    Akhtar, J.; Amin, N.S.; Zahoor, M.K.

    2013-01-01

    Response surface methodology (RSM) has been used to optimize the effect of circulation rates, ozone supply, cephalexin (CEX) concentration, and granular activated carbon (GAC) dose on removal of COD from solution. According to statistical analysis, all of the input variables exerted significant influence on COD removal, however, the effect of interaction variables was not found to be significant on comparative basis. Further, the developed quadratic regression model based on obtained results emphasized the significance of individual terms and little of interaction terms. The values of r/sup 2/ (0.959), adjusted r/sup 2/ (0.902) obtained by analysis of variance (ANOVA) indicates the significance of quadratic model in predicting desired response. The maximum of 70% of COD was removed in these experiments and optimized value according to main effect of variables was 60%. (author)

  7. Controlling the COD removal of an A-stage pilot study with instrumentation and automatic process control.

    Science.gov (United States)

    Miller, Mark W; Elliott, Matt; DeArmond, Jon; Kinyua, Maureen; Wett, Bernhard; Murthy, Sudhir; Bott, Charles B

    2017-06-01

    The pursuit of fully autotrophic nitrogen removal via the anaerobic ammonium oxidation (anammox) pathway has led to an increased interest in carbon removal technologies, particularly the A-stage of the adsorption/bio-oxidation (A/B) process. The high-rate operation of the A-stage and lack of automatic process control often results in wide variations of chemical oxygen demand (COD) removal that can ultimately impact nitrogen removal in the downstream B-stage process. This study evaluated the use dissolved oxygen (DO) and mixed liquor suspended solids (MLSS) based automatic control strategies through the use of in situ on-line sensors in the A-stage of an A/B pilot study. The objective of using these control strategies was to reduce the variability of COD removal by the A-stage and thus the variability of the effluent C/N. The use of cascade DO control in the A-stage did not impact COD removal at the conditions tested in this study, likely because the bulk DO concentration (>0.5 mg/L) was maintained above the half saturation coefficient of heterotrophic organisms for DO. MLSS-based solids retention time (SRT) control, where MLSS was used as a surrogate for SRT, did not significantly reduce the effluent C/N variability but it was able to reduce COD removal variation in the A-stage by 90%.

  8. Enhanced nitrogen removal from piggery wastewater with high NH4+ and low COD/TN ratio in a novel upflow microaerobic biofilm reactor.

    Science.gov (United States)

    Meng, Jia; Li, Jiuling; Li, Jianzheng; Antwi, Philip; Deng, Kaiwen; Nan, Jun; Xu, Pianpian

    2018-02-01

    To enhance nutrient removal more cost-efficiently in microaerobic process treating piggery wastewater characterized by high ammonium (NH 4 + -N) and low chemical oxygen demand (COD) to total nitrogen (TN) ratio, a novel upflow microaerobic biofilm reactor (UMBR) was constructed and the efficiency in nutrient removal was evaluated with various influent COD/TN ratios and reflux ratios. The results showed that the biofilm on the carriers had increased the biomass in the UMBR and enhanced the enrichment of slow-growth-rate bacteria such as nitrifiers, denitrifiers and anammox bacteria. The packed bed allowed the microaerobic biofilm process perform well at a low reflux ratio of 35 with a NH 4 + -N and TN removal as high as 93.1% and 89.9%, respectively. Compared with the previously developed upflow microaerobic sludge reactor, the UMBR had not changed the dominant anammox approach to nitrogen removal, but was more cost-efficiently in treating organic wastewater with high NH 4 + -N and low COD/TN ratio. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Improving bioelectricity generation and COD removal of sewage sludge in microbial desalination cell.

    Science.gov (United States)

    Ebrahimi, Atieh; Yousefi Kebria, Daryoush; Darzi, Ghasem Najafpour

    2018-05-01

    Improving wastewater treatment process and water desalination are two important solutions for increasing the available supply of fresh water. Microbial desalination cells (MDCs) with common electrolytes display relatively low organic matter removal and high cost. In this study, sewage sludge was used as the substrate in the Microbial desalination cell (MDC) under three different initial salt concentrations (5, 20 and 35 g.L -1 ) and the maximum salt removal rates of 50.6%, 64% and 69.6% were obtained under batch condition, respectively. The MDC also produced the maximum power density of 47.1 W m -3 and the averaged chemical oxygen demand (COD) removal of 58.2 ± 0.89% when the initial COD was 6610 ± 83 mg L -1 . Employing treated sludge as catholyte enhanced COD removal and power density to 87.3% and 54.4 W m -3 , respectively, with counterbalancing pH variation in treated effluent. These promising results showed, for the first time, that the excess sewage sludge obtained from biological wastewater treatment plants could be successfully used as anolyte and catholyte in MDC, achieving organic matter biodegradation along with salt removal and energy production. In addition, using treated sludge as catholyte will improve the performance of MDC and introduce a more effective method for both sludge treatment and desalination.

  10. Removal of hard COD, nitrogenous compounds and phenols from a ...

    African Journals Online (AJOL)

    The objective of this study was to identify the factors affecting the suspended and fixed biomass in the removal of hard COD, nitrogenous compounds and phenols from a coal gasification wastewater (CGWW) stream using a hybrid fixed-film bioreactor (H-FFBR) process under real-time plant operational conditions and ...

  11. Cultivation of Chlorella vulgaris JSC-6 with swine wastewater for simultaneous nutrient/COD removal and carbohydrate production.

    Science.gov (United States)

    Wang, Yue; Guo, Wanqian; Yen, Hong-Wei; Ho, Shih-Hsin; Lo, Yung-Chung; Cheng, Chieh-Lun; Ren, Nanqi; Chang, Jo-Shu

    2015-12-01

    Swine wastewater, containing a high concentration of COD and ammonia nitrogen, is suitable for the growth of microalgae, leading to simultaneous COD/nutrients removal from the wastewater. In this study, an isolated carbohydrate-rich microalga Chlorella vulgaris JSC-6 was adopted to perform swine wastewater treatment. Nearly 60-70% COD removal and 40-90% NH3-N removal was achieved in the mixotrophic and heterotrophic culture, depending on the dilution ratio of the wastewater, while the highest removal percentage was obtained with 20-fold diluted wastewater. Mixotrophic cultivation by using fivefold diluted wastewater resulted in the highest biomass concentration of 3.96 g/L. The carbohydrate content of the microalga grown on the wastewater can reach up to 58% (per dry weight). The results indicated that the microalgae-based wastewater treatment can efficiently reduce the nutrients and COD level, and the resulting microalgal biomass had high carbohydrate content, thereby having potential applications for the fermentative production of biofuels or chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Optimizing COD removal from greywater by photoelectro-persulfate process using Box-Behnken design: assessment of effluent quality and electrical energy consumption.

    Science.gov (United States)

    Ahmadi, Mehdi; Ghanbari, Farshid

    2016-10-01

    Greywater (GW) is a potential source for water reuse in various applications. However, GW treatment is still a vital issue in water reuse in cases of environmental standards and risk to public health. This study investigates optimization and modeling of a hybrid process for COD removal from GW. Persulfate (PS) was simultaneously activated by electrogenerated ferrous ion (EC) and UV to generate sulfate radical. Photoelectro-persulfate (PEPS) was optimized by Box-Behnken design and the effects of four variables (pH, PS dosage, current density, and electrolysis time) were evaluated on COD removal. The results and several coefficients showed that the obtained model was acceptable for predicting the COD removal. Moreover, under optimum conditions (pH = 6.9, PS = 8.8 mM, current density = 2.0 mA/cm(2), and 49.3 min electrolysis time), BOD5, turbidity, TSS, phosphate, and UV254 were effectively removed and COD and BOD5 values reached to discharge standards. Different configurations of the processes were assessed for COD removal. The order of COD removal efficiency followed: PS electrical energy consumption was far less than that of photolysis process in hybrid PEPS process.

  13. Textile wastewater treatment: colour and COD removal of reactive black-5 by ozonation

    Science.gov (United States)

    Suryawan, I. W. K.; Helmy, Q.; Notodarmojo, S.

    2018-01-01

    Textile industries produced a large amount of highly coloured wastewater containing variety of dyes in different concentrations. Due to the high concentration of organics in the effluents and the higher stability of modern synthetic dyes, the conventional biological treatment methods are ineffective for the complete colour removal and degradation of organics and dyes. On the other hand, physical-chemical treatment are not destructive, mainly just concentrate and separate the pollutants phases. This research paper investigates the removal of colour and chemical oxygen demand/COD from textile wastewater using ozone treatment. Varied ozone dosages of 1.16; 3.81; 18.79; and 40.88 mg/minute were used in the experiment. Varied wastewater containing Reactive Black 5 (RB-5) concentrations of 40 mg/L, 100 mg/L were also applied. Research result showed the highest colour removal efficiency of 96.9 % was achieved after 5 hours incubation time, while the highest COD removal efficiency of 77.5% was achieved after 2 hours incubation time.

  14. Process contribution evaluation for COD removal and energy production from molasses wastewater in a BioH2-BioCH4-MFC-integrated system.

    Science.gov (United States)

    Yun, Jeonghee; Lee, Yun-Yeong; Choi, Hyung Joo; Cho, Kyung-Suk

    2017-01-01

    In this study, a three-stage-integrated process using the hydrogenic process (BioH 2 ), methanogenic process (BioCH 4 ), and a microbial fuel cell (MFC) was operated using molasses wastewater. The contribution of individual processes to chemical oxygen demand (COD) removal and energy production was evaluated. The three-stage integration system was operated at molasses of 20 g-COD L -1 , and each process achieved hydrogen production rate of 1.1 ± 0.24 L-H 2 L -1 day -1 , methane production rate of 311 ± 18.94 mL-CH 4 L -1 day -1 , and production rate per electrode surface area of 10.8 ± 1.4 g m -2 day -1 . The three-stage integration system generated energy production of 32.32 kJ g-COD -1 and achieved COD removal of 98 %. The contribution of BioH 2 , BioCH 4 , and the MFC reactor was 20.8, 72.2, and, 7.0 % of the total COD removal, and 18.7, 81.2, and 0.16 % of the total energy production, respectively. The continuous stirred-tank reactor BioH 2 at HRT of 1 day, up-flow anaerobic sludge blanket BioCH 4 at HRT of 2 days, and MFC reactor at HRT of 3 days were decided in 1:2:3 ratios of working volume under hydraulic retention time consideration. This integration system can be applied to various configurations depending on target wastewater inputs, and it is expected to enhance energy recovery and reduce environmental impact of the final effluent.

  15. Removal of COD and color loads in bleached kraft pulp effluents by bottom ashes from boilers.

    Science.gov (United States)

    Van Tran, A

    2008-07-01

    The effectiveness of the bottom ashes from biomass and coal-fired boilers in removing chemical oxygen demand (COD) and colorloads in effluents of a kraft pulp bleachery plant is investigated. The effluents tested are those of the sulfuric acid treatment (A stage) of a hardwood kraft pulp, and of the first acidic (chlorine or chlorine dioxide) and second alkaline (extraction) stages in the chlorine and elemental chlorine-free (ECF) bleaching lines of hardwood and softwood kraft pulps. The coal-fired boiler's bottom ashes are unable to remove either COD or color load in the bleached kraft pulp effluents. However, the bottom ashes of the biomass boiler are effective in removing COD and color loads of the acidic and alkaline effluents irrespective of the bleaching process or wood species. In particular, these ashes increase the pH of all the effluents examined.

  16. Degradation and COD removal of catechol in wastewater using the catalytic ozonation process combined with the cyclic rotating-bed biological reactor.

    Science.gov (United States)

    Aghapour, Ali Ahmad; Moussavi, Gholamreza; Yaghmaeian, Kamyar

    2015-07-01

    The effect of ozonation catalyzed with MgO/granular activated carbon (MgO/GAC) composite as a pretreatment process on the performance of cyclic rotating-bed biological reactor (CRBR) for the catechol removal from wastewater has been investigated. CRBR with acclimated biomasses could efficiently remove catechol and its related COD from wastewater at organic loading rate (OLR) of 7.82 kg COD/m(3).d (HRT of 9 h). Then, OLR increased to 15.64 kg COD/m(3).d (HRT of 4.5 h) and CRBR failed. Catalytic ozonation process (COP) used as a pre-treatment and could improve the performance of the failed CRBR. The overall removal efficiency of the combined process attained respective steady states of 91% and 79% for degradation and COD removal of catechol. Therefore, the combined process is more effective in degradation and COD removal of catechol; it is also a viable alternative for upgrading industrial wastewater treatment plant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. An integrated mathematical model for chemical oxygen demand (COD) removal in moving bed biofilm reactors (MBBR) including predation and hydrolysis.

    Science.gov (United States)

    Revilla, Marta; Galán, Berta; Viguri, Javier R

    2016-07-01

    An integrated mathematical model is proposed for modelling a moving bed biofilm reactor (MBBR) for removal of chemical oxygen demand (COD) under aerobic conditions. The composite model combines the following: (i) a one-dimensional biofilm model, (ii) a bulk liquid model, and (iii) biological processes in the bulk liquid and biofilm considering the interactions among autotrophic, heterotrophic and predator microorganisms. Depending on the values for the soluble biodegradable COD loading rate (SCLR), the model takes into account a) the hydrolysis of slowly biodegradable compounds in the bulk liquid, and b) the growth of predator microorganisms in the bulk liquid and in the biofilm. The integration of the model and the SCLR allows a general description of the behaviour of COD removal by the MBBR under various conditions. The model is applied for two in-series MBBR wastewater plant from an integrated cellulose and viscose production and accurately describes the experimental concentrations of COD, total suspended solids (TSS), nitrogen and phosphorous obtained during 14 months working at different SCLRs and nutrient dosages. The representation of the microorganism group distribution in the biofilm and in the bulk liquid allow for verification of the presence of predator microorganisms in the second reactor under some operational conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Nitrogen and COD removal from domestic and synthetic wastewater in subsurface-flow constructed wetlands.

    Science.gov (United States)

    Collison, R S; Grismer, M E

    2013-09-01

    Comparisons of the performance of constructed-wetland systems (CWs) for treating domestic wastewater in the laboratory and field may use pathogen-free synthetic wastewater to avoid regulatory health concerns. However, little to no data are available describing the relative treatment efficiencies of CWs to both actual and synthetic domestic wastewaters so as to enable such comparison. To fill this gap, treatment performances with respect to organics (chemical organic demand; COD) and nitrogen (ammonium and nitrate) removal from domestic (septic tank) and a similar-strength synthetic wastewater under planted and non-planted subsurface-flow CWs are determined. One pair of CWs was planted with cattails in May 2008, whereas the adjacent system was non-planted. Collected septic tank or synthesized wastewater was allowed to gravity feed each CWs, and effluent samples were collected and tested for COD and nitrogen species regularly during four different periods over six months. Overall, statistically significant greater removal of COD (-12%) and nitrogen (-5%) occurred from the synthetic as compared with the domestic wastewater from the planted and non-planted CWs. Effluent BOD5/COD ratios from the synthetic wastewater CWs averaged nearly twice that from the domestic wastewater CWs (0.17 vs 0.10), reflecting greater concentrations of readily degraded compounds. That removal fractions were consistent across the mid-range loading rates to the CWs suggests that the synthetic wastewater can be used in testing laboratory CWs with reasonable success in application of their results to the field.

  19. THE EFFECT OF INFLUENT CONCENTRATION AND HYDRAULIC LOADING RATE (HLR TO BOD AND COD REMOVAL ON ARTIFICIAL DOMESTIC WASTEWATER TREATMENT (GREY WATER USING UASB REACTOR

    Directory of Open Access Journals (Sweden)

    Syafrudin Syafrudin

    2014-05-01

    Full Text Available Upflow anaerobic sludge blanket (UASB reactor is one of anaerobic biological treatment was develop in late 1970’s. UASB reactor is suitable for the tropic areas because it has a high temperature about 20°-30°C. Domestic wastewater is divided into two types, namely black water and grey water. But in this case used domestic grey water. Grey water is household wastewater from showers, sinks and kitchen. Grey water has a total 75% of the domestic wastewater volume. The research was conducted in laboratory scale. This study performed a variation of Hydraulic Loading Rate (HLR and the influent concentration. There were 25 reactors include 5 variations of influent concentration and 5 Hydraulic Loading Rate’s (HLR variation. The research could asses BOD5 and COD removal with treatment in UASB. Efficiency of BOD5 removal by varying the influent concentration and HLR was about 38%-75% and COD was about 40%-77%. The lower concentration could be increase efficiency BOD5 and COD removal. Influent concentration optimum occurred when middle concentration was about 840 mg/L COD and HLR optimum was 0,05 m3/m2/hour.

  20. Efficacy of HRF in COD Removal from Secondary Effluent of Yasuj Municipal Wastewater

    Directory of Open Access Journals (Sweden)

    M Ehteshami

    2011-10-01

    Full Text Available Background & Aim: Re-use of wastewater is an appropriate approach for development of water resources and water supply strategies. The purpose of this study was to determine the efficacy of HRF in COD removal from secondary effluent of municipal wastewater in Yasouj. Methods: The pilot which was used in the present study was a horizontal roughing filter designed and prepared according to the Wegelin’s Design Criteria. The Samples were removed daily and instantaneous based on the predicted number of samples (28 samples at each filtration rate from the input and output filter, and then tested in the laboratory by the D5000 device. The collected data was analyzed using ANOVA and paired t-test. Results: The results indicated that the average COD removal in the filtration rate of 0.5, 1, and 1.5 were 60, 51, and 38 percent respectively. Conclusion: The average output of the HRF for all three filtration rates was lower than the maximum EPA standard of Iran.

  1. Effect of Vermifiltration on COD and Color Removal from Textile Factories’ Waste Water

    Directory of Open Access Journals (Sweden)

    Rabbani D.1 PhD,

    2015-09-01

    Full Text Available Aims Textile industries are among the manufactures which produce the highly polluted waste water. The purpose of this research was to evaluate the effect of vermifiltration on COD and color removal from textile waste water. Materials & Methods This experimental research was performed March to August 2014 in one of the textile factories of Kashan region, Iran. The glass cubic kits with- without Eisenia fetida were used to filter the waste water samples. Data was analyzed using Kruskal–Wallis and two-way analysis of variance in SPSS 19 statistical software. Findings The mean of COD concentration in the raw waste water samples was 1324.24±757.01mg/l which was decreased to 598.22±349.33 and 831.32±445.19mg/l after the experimental and control kits usage, respectively (p<0.001. The mean of color intensity in raw waste water samples was 51.2±30.6% which was decreased to 27.8±15.0 and 27.4±15.1% (p=0.635 in experimental and control kits, respectively. There was a significant negative correlation between COD removal and hydraulic loads (p<0.001; r=-0.804 and a significant negative correlation between color removal and hydraulic loads (p<0.001; r=- 0.278 in both experimental and control kits. Conclusion The most important risk groups in our study were abattoir workers, butchers, housewives and students who handle infected animals.

  2. Reactor performance in terms of COD and nitrogen removal and bacterial community structure of a three-stage rotating bioelectrochemical contactor

    KAUST Repository

    Sayess, Rassil R.

    2013-02-01

    Integrating microbial fuel cell (MFC) into rotating biological contactor (RBC) creates an opportunity for enhanced removal of COD and nitrogen coupled with energy generation from wastewater. In this study, a three-stage rotating bioelectrochemical contactor (referred to as RBC-MFC unit) integrating MFC with RBC technology was constructed for simultaneous removal of carbonaceous and nitrogenous compounds and electricity generation from a synthetic medium containing acetate and ammonium. The performance of the RBC-MFC unit was compared to a control reactor (referred to as RBC unit) that was operated under the same conditions but without current generation (i.e. open-circuit mode). The effect of hydraulic loading rate (HLR) and COD/N ratio on the performance of the two units was investigated. At low (3.05 gCOD g-1N) and high COD/N ratio (6.64 gCOD g-1N), both units achieved almost similar COD and ammonia-nitrogen removal. However, the RBC-MFC unit achieved significantly higher denitrification and nitrogen removal compared to the RBC unit indicating improved denitrification at the cathode due to current flow. The average voltage under 1000 Ω external resistance ranged between 0.03 and 0.30 V and between 0.02 and 0.21 V for stages 1 and 2 of the RBC-MFC unit. Pyrosequencing analysis of bacterial 16S rRNA gene revealed high bacterial diversity at the anode and cathode of both units. Genera that play a role in nitrification (Nitrospira; Nitrosomonas), denitrification (Comamonas; Thauera) and electricity generation (Geobacter) were identified at the electrodes. Geobacter was only detected on the anode of the RBC-MFC unit. Nitrifiers and denitrifiers were more abundant in the RBC-MFC unit compared to the RBC unit and were largely present on the cathode of both units suggesting that most of the nitrogen removal occurred at the cathode. © 2012 Elsevier Ltd.

  3. Assessment of Electrocoagulation Method for Simultaneous Removal of Phosphate, Nitrate and COD by Fe Electrodes from Laundry Wastewater

    Directory of Open Access Journals (Sweden)

    Marzieh Razavi

    2013-12-01

    Full Text Available Background & Objectives: Discharging of wastewaters containing detergents either by manufacturers or through domestic and industrial usages has caused the incidence of serious environmental problems. Entering these materials in to the surface waters reduces the amount of dissolved oxygen in the water and causes unsightly environment and groundwater pollution that is always has been notified by environmental experts. Methods: This study focuses on the treatment of laundry wastewater containing phosphate, nitrate and COD using iron as sacrificial electrode by EC process. Various operating conditions such as pH (3, 4, 5, 6, 7, 9, distance between the electrode (3, 5, 10,15mm and current density (3, 6,9,12 mA/cm2 were investigated. Results: Experimental results showed that pollutant removal efficiency varied by changing pH, distance between the electrodes and current density. According to the results, optimum operating conditions for the removal of phosphate, nitrate and COD, were current density of 12mA/cm2, pH of 7.0, distance between the electrodes equal to 10 mm with Fe electrodes. The removal efficiency of phosphate, nitrate and COD were showed 99.33%, 96.67% and 91.43%. Also Kinetic analysis indicates that the adsorption system obeys a second- order kinetic model. Conclusion: According to the results, the Fe electrodes have been achieved the high removal efficiency of phosphate, nitrate and COD by using electrocoagulation.

  4. The removal of COD and NH3-N from atrazine production wastewater treatment using UV/O3: experimental investigation and kinetic modeling.

    Science.gov (United States)

    Jing, Liang; Chen, Bing; Wen, Diya; Zheng, Jisi; Zhang, Baiyu

    2018-01-01

    In this study, a UV/O 3 hybrid advanced oxidation system was used to remove chemical oxygen demand (COD), ammonia nitrogen (NH 3 -N), and atrazine (ATZ) from ATZ production wastewater. The removal of COD and NH 3 -N, under different UV and O 3 conditions, was found to follow pseudo-first-order kinetics with rate constants ranging from 0.0001-0.0048 and 0.0015-0.0056 min -1 , respectively. The removal efficiency of ATZ was over 95% after 180 min treatment, regardless the level of UV power. A kinetic model was further proposed to simulate the removal processes and to quantify the individual roles and contributions of photolysis, direct O 3 oxidation, and hydroxyl radical (OH·) induced oxidation. The experimental and kinetic modeling results agreed reasonably well with deviations of 12.2 and 13.1% for the removal of COD and NH 3 -N, respectively. Photolysis contributed appreciably to the degradation of ATZ, while OH· played a dominant role for the removal of both COD and NH 3 -N, especially in alkaline environments. This study provides insights into the treatment of ATZ containing wastewater using UV/O 3 and broadens the knowledge of kinetics of ozone-based advanced oxidation processes.

  5. Removal of COD, phenols and ammonium from Lurgi coal gasification wastewater using A2O-MBR system

    International Nuclear Information System (INIS)

    Wang, Zixing; Xu, Xiaochen; Gong, Zheng; Yang, Fenglin

    2012-01-01

    Highlights: ► Anaerobic–anoxic–aerobic MBR system treated the coal gasification wastewater. ► COD removal rate was 97.4% with effluent concentration less than 100 mg/L. ► NH 4 + -N removal rate was 92.8% with effluent concentration less than 12 mg/L. ► HRT and recycle ratio strongly affected the performance of the system. ► GC/MS analysis found refractory organic removal in anaerobic and anoxic stage. - Abstract: As a typical industrial wastewater, coal gasification wastewater has poor biodegradability and high toxicity. In this paper, a laboratory-scale anaerobic–anoxic–oxic membrane reactor (A 2 O-MBR) system was developed to investigate the treatment ability of coal gasification wastewater. The removal capacity of each pollutants used in this system were determined at different hydraulic residence times (HRT) and mixed liquor recycle ratios (R). The experimental results showed that this system could effectively deal with COD and phenol removal and remain in a stable level when the operational parameters altered, while the nitrification was sensitive to operational conditions. The best performance was obtained at HRT of 48 h and R of 3. The maximum removal efficiencies of COD, NH 4 + -N and phenols were 97.4%, 92.8% and 99.7%, with final concentrations in the effluent of 71 mg/L, 9.6 mg/L and 3 mg/L, respectively. Organics degradation and transformation were analyzed by GC/MS and it was found that anaerobic process played an important role in degradation of refractory compounds.

  6. The Use of Electrocoagulation Process for Removal of Turbidity, COD, Detergent and Phosphorus from Carwash Effluent

    Directory of Open Access Journals (Sweden)

    Afshin Takdastan

    2011-10-01

    Full Text Available This study evaluated the efficiency of Electrical coagulation process in removal of COD, turbidity, detergent and phosphate from carwash effluent. An experimental study in laboratory scale was carried out and a glass tank with volume of 3 liters (effective volume of 2 liters containing 4 electrode-page iron and aluminum (AL-AL, AL-Fe, Fe-Fe were used. Electrodes were connected to a power supply with using bipolar method to convert alternative electricity to direct current. Daily samples were collected from different carwash effluents. Initial pH of samples were reported between 7 to 9.At first different tests were performed on primary samples. Percentage of removal was calculated in range pH and electrical potential of 11, 7, 3 and 30, 20, 10 volts respectively. Reaction times were set 90, 60, 30 minutes with middle intervals of 2 cm. The results showed the efficiency of COD removal in the optimum range of  pH=3, voltage of 30 and retention time of 90 minutes removal efficiency in pH of 7 after 90 minutes retention time, voltage of 30, with aluminum electrode reached more than 99%. According to the results obtained electrical energy consumption in aluminum electrodes was less than others. However aluminum is more expensive than iron and the difference in energy consumption between iron and aluminum can be ingnored. Apart from that COD and detergent removal efficiency of iron electrodes is higher than aluminum electrodes therefore, using iron as the electrode is more economical and recommended. Altogether it was found that this method can be use as a safe and convenient method for treating carwash effluent and according to the high removal efficiency of process, effluent can be discharged safely into the environment.

  7. The effect of COD loading on the granule-based enhanced biological phosphorus removal system and the recoverability.

    Science.gov (United States)

    Yu, Shenjing; Sun, Peide; Zheng, Wei; Chen, Lujun; Zheng, Xiongliu; Han, Jingyi; Yan, Tao

    2014-11-01

    In this study, the effect of varied COD loading (200, 400, 500, 600 and 800 mg L(-1)) on stability and recoverability of granule-based enhanced biological phosphorus removal (EBPR) system was investigated during continuously 53-d operation. Results showed that COD loading higher than 500 mg L(-1) could obviously deteriorate the granular EBPR system and result in sludge bulking with filamentous bacteria. High COD loading also changed the transformation patterns of poly-β-hydroxyalkanoates (PHAs) and glycogen in metabolism process of polyphosphate-accumulating organisms (PAOs) and inhibited the EPS secretion, which completely destroyed the stability and integrality of granules. Results of FISH indicated that glycogen-accumulating organisms (GAOs) and other microorganisms had a competitive advantage over PAOs with higher COD loading. The community composition and EBPR performance were recovered irreversibly in long time operation when COD loading was higher than 500 mg L(-1). Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Comparison of coagulation, ozone and ferrate treatment processes for color, COD and toxicity removal from complex textile wastewater.

    Science.gov (United States)

    Malik, Sameena N; Ghosh, Prakash C; Vaidya, Atul N; Waindeskar, Vishal; Das, Sera; Mudliar, Sandeep N

    2017-09-01

    In this study, the comparative performance of coagulation, ozone, coagulation + ozone + coagulation and potassium ferrate processes to remove chemical oxygen demand (COD), color, and toxicity from a highly polluted textile wastewater were evaluated. Experimental results showed that ferrate alone had no effect on COD, color and toxicity removal. Whereas, in combination with FeSO 4 , it has shown the highest removal efficiency of 96.5%, 83% and 75% for respective parameters at the optimal dose of 40 mgL -1 + 3 ml FeSO 4 (1 M) in comparison with other processes. A seed germination test using seeds of Spinach (Spinacia oleracea) also indicated that ferrate was more effective in removing toxicity from contaminated textile wastewater. Potassium ferrate also produces less sludge with maximum contaminant removal, thereby making the process more economically feasible. Fourier transform infrared spectroscopy (FTIR) analysis also shows the cleavage of the chromophore group and degradation of textile wastewater during chemical and oxidation treatment processes.

  9. Evaluation of simultaneous nutrient and COD removal with polyhydroxybutyrate (PHB) accumulation using mixed microbial consortia under anoxic condition and their bioinformatics analysis.

    Science.gov (United States)

    Jena, Jyotsnarani; Kumar, Ravindra; Dixit, Anshuman; Pandey, Sony; Das, Trupti

    2015-01-01

    Simultaneous nitrate-N, phosphate and COD removal was evaluated from synthetic waste water using mixed microbial consortia in an anoxic environment under various initial carbon load (ICL) in a batch scale reactor system. Within 6 hours of incubation, enriched DNPAOs (Denitrifying Polyphosphate Accumulating Microorganisms) were able to remove maximum COD (87%) at 2 g/L of ICL whereas maximum nitrate-N (97%) and phosphate (87%) removal along with PHB accumulation (49 mg/L) was achieved at 8 g/L of ICL. Exhaustion of nitrate-N, beyond 6 hours of incubation, had a detrimental effect on COD and phosphate removal rate. Fresh supply of nitrate-N to the reaction medium, beyond 6 hours, helped revive the removal rates of both COD and phosphate. Therefore, it was apparent that in spite of a high carbon load, maximum COD and nutrient removal can be maintained, with adequate nitrate-N availability. Denitrifying condition in the medium was evident from an increasing pH trend. PHB accumulation by the mixed culture was directly proportional to ICL; however the time taken for accumulation at higher ICL was more. Unlike conventional EBPR, PHB depletion did not support phosphate accumulation in this case. The unique aspect of all the batch studies were PHB accumulation was observed along with phosphate uptake and nitrate reduction under anoxic conditions. Bioinformatics analysis followed by pyrosequencing of the mixed culture DNA from the seed sludge revealed the dominance of denitrifying population, such as Corynebacterium, Rhodocyclus and Paraccocus (Alphaproteobacteria and Betaproteobacteria). Rarefaction curve indicated complete bacterial population and corresponding number of OTUs through sequence analysis. Chao1 and Shannon index (H') was used to study the diversity of sampling. "UCI95" and "LCI95" indicated 95% confidence level of upper and lower values of Chao1 for each distance. Values of Chao1 index supported the results of rarefaction curve.

  10. Evaluation of simultaneous nutrient and COD removal with polyhydroxybutyrate (PHB accumulation using mixed microbial consortia under anoxic condition and their bioinformatics analysis.

    Directory of Open Access Journals (Sweden)

    Jyotsnarani Jena

    Full Text Available Simultaneous nitrate-N, phosphate and COD removal was evaluated from synthetic waste water using mixed microbial consortia in an anoxic environment under various initial carbon load (ICL in a batch scale reactor system. Within 6 hours of incubation, enriched DNPAOs (Denitrifying Polyphosphate Accumulating Microorganisms were able to remove maximum COD (87% at 2 g/L of ICL whereas maximum nitrate-N (97% and phosphate (87% removal along with PHB accumulation (49 mg/L was achieved at 8 g/L of ICL. Exhaustion of nitrate-N, beyond 6 hours of incubation, had a detrimental effect on COD and phosphate removal rate. Fresh supply of nitrate-N to the reaction medium, beyond 6 hours, helped revive the removal rates of both COD and phosphate. Therefore, it was apparent that in spite of a high carbon load, maximum COD and nutrient removal can be maintained, with adequate nitrate-N availability. Denitrifying condition in the medium was evident from an increasing pH trend. PHB accumulation by the mixed culture was directly proportional to ICL; however the time taken for accumulation at higher ICL was more. Unlike conventional EBPR, PHB depletion did not support phosphate accumulation in this case. The unique aspect of all the batch studies were PHB accumulation was observed along with phosphate uptake and nitrate reduction under anoxic conditions. Bioinformatics analysis followed by pyrosequencing of the mixed culture DNA from the seed sludge revealed the dominance of denitrifying population, such as Corynebacterium, Rhodocyclus and Paraccocus (Alphaproteobacteria and Betaproteobacteria. Rarefaction curve indicated complete bacterial population and corresponding number of OTUs through sequence analysis. Chao1 and Shannon index (H' was used to study the diversity of sampling. "UCI95" and "LCI95" indicated 95% confidence level of upper and lower values of Chao1 for each distance. Values of Chao1 index supported the results of rarefaction curve.

  11. Rice hull/MnFe2O4 composite: Preparation, characterization and its rapid microwave-assisted COD removal for organic wastewater

    International Nuclear Information System (INIS)

    Lv Shuangshuang; Chen Xuegang; Ye Ying; Yin Suhang; Cheng Jipeng; Xia Meisheng

    2009-01-01

    Adsorbent/ferrite composites can adsorb and degrade organics in the organic wastewater treatment. In this study, a rice hull/MnFe 2 O 4 composite (RHM) was prepared via calcination under nitrogen atmosphere and was used to treat organic wastewater with the assistance of microwave radiation. Rice hull was pyrolysed to a porous substrate that consisted of silica and activated carbon under high temperature. Monodisperse spinel MnFe 2 O 4 nanoparticles whose mean diameter is around 59 nm are distributed on the substrate. With the assistance of microwave radiation, RHM was motivated to a hotspot of adsorption and catalysis which could remove more than 70% COD of wastewater within 6 min. The maximum COD removal was 73.5% when the concentration of RHM was 15 mg mL -1 and the irradiation time of microwave radiation was 6 min. Although the BET surface area and iodine value of RHM are half of rice hull ash (RHA), the COD removal of RHM is 7-20% higher than that of RHA. It is attributed to the presence of MnFe 2 O 4 , which enhances the catalytic activity of RHM. RHM can be regenerated via water washing. However, the surface area and the maximum COD removal of RHM decrease for each regeneration cycle. With the advantages of low cost and rapid processing, this novel rice hull/MnFe 2 O 4 composite could gain promising application in wastewater treating-agent.

  12. Low-cost adsorbent prepared from sewage sludge and corn stalk for the removal of COD in leachate.

    Science.gov (United States)

    He, Ying; Liao, Xiaofeng; Liao, Li; Shu, Wei

    2014-01-01

    Sewage sludge (SS) with corn stalk (CS) was used to prepare SS-based activated carbon (SAC) by pyrolysis with ZnCl2. The effects of mixing ratio on surface area and pore size distribution, elemental composition, surface chemistry, and morphology were investigated. The results demonstrated that the addition of CS into SS samples improved the surface area (from 92 to 902 m(2)/g) and the microporosity (from 1.2 to 4.1%) of the adsorbents and, therefore, enhancing the adsorption performance. The removal of leachate chemical oxygen demand (COD) was also determined. It was found that the COD removal rate reached 85% at pH 4 with the SAC (90 wt% CS) dosage of 2% (g/mL) and an adsorption time of 40 min. The adsorption experimental data were fitted by both Langmuir and Freundlich adsorption isotherms. Long-chain alkanes and refractory organics were found in raw leachate, but could be removed by SAC largely.

  13. Effect of sludge retention time on continuous-flow system with enhanced biological phosphorus removal granules at different COD loading.

    Science.gov (United States)

    Li, Dong; Lv, Yufeng; Zeng, Huiping; Zhang, Jie

    2016-11-01

    The effect of sludge retention time (SRT) on the continuous-flow system with enhanced biological phosphorus removal (EBPR) granules at different COD loading was investigated during the operation of more than 220days. And the results showed that when the system operated at long SRT (30days) and low COD loading (200mg·L(-1)), it could maintain excellent performance. However, long SRT and high COD loading (300mg·L(-1)) deteriorated the settling ability of granules and the performance of system and resulted in the overgrowth of filamentous bacteria. Meanwhile, the transformation of poly-β-hydroxyalkanoates (PHAs) and glycogen in metabolism process was inhibited. Moreover, the results of pyrosequencing indicated that filamentous bacteria had a competitive advantage over polyphosphate-accumulating organisms (PAOs) at high COD loading and long SRT. The PAOs specious of Candidatus_Accumlibater and system performance increased obviously when the SRT was reduced to 20days at high COD loading. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Lipid production from tapioca wastewater by culture of Scenedesmus sp. with simultaneous BOD, COD and nitrogen removal

    Science.gov (United States)

    Romaidi; Hasanudin, Muhammad; Kholifah, Khusnul; Maulidiyah, Alik; Putro, Sapto P.; Kikuchi, Akira; Sakaguchi, Toshifumi

    2018-05-01

    The use of microalgae to produce biodiesel or possibly remove nutrients from industrial wastewater has gained important attention during recent years due to their photosynthetic rate and its versatile nature to grow in various wastewater systems. In this study, a microalgae, Scenedesmus sp., was cultured to enhance the lipid production and nutrients removal from tapioca wastewater sample. To assess lipid production, Scenedesmus sp. was cultured in different concentration of tapioca wastewater sample (from 0 to 100 %), and nutrient removal including BOD, COD, NH4, NO2, NO3 level by Scenedesmus sp. was assessed in 100% of tapioca wastewater culture. After 8 days of culture, it was found out that 50% of tapioca wastewater sample resulted in highest concentration of lipid content than that of the other concentrations. The level of environment indicator as nutrient removal such as BOD, COD, NH4, NO2, NO3 were also decreased up to 74%, 72%, 95%, 91%, and 91%, respectively. The pH condition changed from initial condition acidic (pH: 4) to neutral or basic condition (pH: 7-8) as recommended in wastewater treatment system. This research provided a novel approach and achieved efficient simultaneous lipid production and nutrients removal from tapioca wastewater sample by Scenedesmus’s culture system.

  15. Nitrogen and COD Removal from Septic Tank Wastewater in Subsurface Flow Constructed Wetlands: Plants Effects.

    Science.gov (United States)

    Collison, R S; Grismer, M E

    2015-11-01

    We evaluated subsurface flow (SSF) constructed wetland treatment performance with respect to organics (COD) and nitrogen (ammonium and nitrate) removal from domestic (septic tank) wastewater as affected by the presence of plants, substrate "rock" cation exchange capacity (CEC), laboratory versus field conditions and use of synthetic as compared to actual domestic wastewater. This article considers the effects of plants on constructed wetland treatment in the field. Each constructed wetland system was comprised of two beds (2.6 m long by 0.28 m wide and deep filled with ~18 mm crushed lava rock) separated by an aeration tank connected in series. The lava rock had a porosity of ~47% and a CEC of 4 meq/100 gm. One pair of constructed wetland systems was planted with cattails in May 2008, while an adjacent pair of systems remained un-planted. Collected septic tank or synthesized wastewater was allowed to gravity feed each constructed wetland system and effluent samples were regularly collected and tested for COD and nitrogen species during four time periods spanning November 2008 through June 2009. These effluent concentrations were tested for statistical differences at the 95% level for individual time periods as well as the overall 6-month period. Organics removal from domestic wastewater was 78.8% and 76.1% in the planted and un-planted constructed wetland systems, respectively, while ammonium removal was 94.5% and 90.2%, respectively. Similarly, organics removal from the synthetic wastewater of equivalent strength was 88.8% and 90.1% for planted and un-planted constructed wetland systems, respectively, while ammonium removal was 96.9% and 97.3%, respectively.

  16. Effect of influent COD/SO4(2-) ratios on UASB treatment of a synthetic sulfate-containing wastewater.

    Science.gov (United States)

    Hu, Yong; Jing, Zhaoqian; Sudo, Yuta; Niu, Qigui; Du, Jingru; Wu, Jiang; Li, Yu-You

    2015-07-01

    The effect of the chemical oxygen demand/sulfate (COD/SO4(2-)) ratio on the anaerobic treatment of synthetic chemical wastewater containing acetate, ethanol, and sulfate, was investigated using a UASB reactor. The experimental results show that at a COD/SO4(2-) ratio of 20 and a COD loading rate of 25.2gCODL(-1)d(-1), a COD removal of as high as 87.8% was maintained. At a COD/SO4(2-) ratio of 0.5 (sulfate concentration 6000mgL(-1)), however, the COD removal was 79.2% and the methane yield was 0.20LCH4gCOD(-1). The conversion of influent COD to methane dropped from 80.5% to 54.4% as the COD/SO4(2-) ratio decreased from 20 to 0.5. At all the COD/SO4(2-) ratios applied, over 79.4% of the total electron flow was utilized by methane-producing archaea (MPA), indicating that methane fermentation was the predominant reaction. The majority of the methane was produced by acetoclastic MPA at high COD/SO4(2-) ratios and both acetoclastic and hydrogenthrophic MPA at low COD/SO4(2-) ratios. Only at low COD/SO4(2-) ratios were SRB species such as Desulfovibrio found to play a key role in ethanol degradation, whereas all the SRB species were found to be incomplete oxidizers at both high and low COD/SO4(2-) ratios. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Relationships between chemical oxygen demand (COD) components and toxicity in a sequential anaerobic baffled reactor/aerobic completely stirred reactor system treating Kemicetine

    Energy Technology Data Exchange (ETDEWEB)

    Sponza, Delia Teresa, E-mail: delya.sponza@deu.edu.tr [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eyluel University, Buca Kaynaklar Campus, Tinaztepe, 35160 Izmir (Turkey); Demirden, Pinar, E-mail: pinar.demirden@kozagold.com [Environmental Engineer, Koza Gold Company, Environmental Department, Ovacik, Bergama Izmir (Turkey)

    2010-04-15

    In this study the interactions between toxicity removals and Kemicetine, COD removals, intermediate products of Kemicetine and COD components (CODs originating from slowly degradable organics, readily degradable organics, inert microbial products and from the inert compounds) were investigated in a sequential anaerobic baffled reactor (ABR)/aerobic completely stirred tank reactor (CSTR) system with a real pharmaceutical wastewater. The total COD and Kemicetine removal efficiencies were 98% and 100%, respectively, in the sequential ABR/CSTR systems. 2-Amino-1 (p-nitrophenil)-1,3 propanediol, l-p-amino phenyl, p-amino phenol and phenol were detected in the ABR as the main readily degradable inter-metabolites. In the anaerobic ABR reactor, the Kemicetin was converted to corresponding inter-metabolites and a substantial part of the COD was removed. In the aerobic CSTR reactor the inter-metabolites produced in the anaerobic reactor were completely removed and the COD remaining from the anerobic reactor was biodegraded. It was found that the COD originating from the readily degradable organics did not limit the anaerobic degradation process, while the CODs originating from the slowly degradable organics and from the inert microbial products significantly decreased the anaerobic ABR reactor performance. The acute toxicity test results indicated that the toxicity decreased from the influent to the effluent of the aerobic CSTR reactor. The ANOVA test statistics showed that there was a strong linear correlation between acute toxicity, CODs originating from the slowly degradable organics and inert microbial products. A weak correlation between acute toxicity and CODs originating from the inert compounds was detected.

  18. Relationships between chemical oxygen demand (COD) components and toxicity in a sequential anaerobic baffled reactor/aerobic completely stirred reactor system treating Kemicetine

    International Nuclear Information System (INIS)

    Sponza, Delia Teresa; Demirden, Pinar

    2010-01-01

    In this study the interactions between toxicity removals and Kemicetine, COD removals, intermediate products of Kemicetine and COD components (CODs originating from slowly degradable organics, readily degradable organics, inert microbial products and from the inert compounds) were investigated in a sequential anaerobic baffled reactor (ABR)/aerobic completely stirred tank reactor (CSTR) system with a real pharmaceutical wastewater. The total COD and Kemicetine removal efficiencies were 98% and 100%, respectively, in the sequential ABR/CSTR systems. 2-Amino-1 (p-nitrophenil)-1,3 propanediol, l-p-amino phenyl, p-amino phenol and phenol were detected in the ABR as the main readily degradable inter-metabolites. In the anaerobic ABR reactor, the Kemicetin was converted to corresponding inter-metabolites and a substantial part of the COD was removed. In the aerobic CSTR reactor the inter-metabolites produced in the anaerobic reactor were completely removed and the COD remaining from the anerobic reactor was biodegraded. It was found that the COD originating from the readily degradable organics did not limit the anaerobic degradation process, while the CODs originating from the slowly degradable organics and from the inert microbial products significantly decreased the anaerobic ABR reactor performance. The acute toxicity test results indicated that the toxicity decreased from the influent to the effluent of the aerobic CSTR reactor. The ANOVA test statistics showed that there was a strong linear correlation between acute toxicity, CODs originating from the slowly degradable organics and inert microbial products. A weak correlation between acute toxicity and CODs originating from the inert compounds was detected.

  19. Effect of color removal agent on textiles waste water

    International Nuclear Information System (INIS)

    Khomsaton Abu Bakar; Selambakknu, Sarala; Jamaliah Shariff; Ting, Teo Ming; Khairul Zaman Dahlan

    2010-01-01

    The effect of color removal agent (CRA) on textile waste water has been studied. The aim of this work is to determine the optimum condition for CRA to react on the textile waste water and to see the effect of CRA on waste water with different Chemical Oxygen Demand. 8 ml CRA was used to treat 800 mls of sample with various COD ranging between 2500 mg/ l-500 mg/ l. The results showed that CRA totally remove the colour of textile waste water at pH ranging from 6 to 8. At an optimum condition CRA works efficiently on waste water with COD 2300 mg/ l for reduction of suspended solid and turbidity. It also observed, sludge accumulation was depended on COD concentration. Color removal curves for different initial COD concentration also obtained. (author)

  20. Evaluating photo-degradation of COD and TOC in petroleum refinery wastewater by using TiO2/ZnO photo-catalyst.

    Science.gov (United States)

    Aljuboury, Dheeaa Al Deen Atallah; Palaniandy, Puganeshwary; Abdul Aziz, Hamidi Bin; Feroz, Shaik; Abu Amr, Salem S

    2016-09-01

    The aim of this study is to investigate the performance of combined solar photo-catalyst of titanium oxide/zinc oxide (TiO 2 /ZnO) with aeration processes to treat petroleum wastewater. Central composite design with response surface methodology was used to evaluate the relationships between operating variables for TiO 2 dosage, ZnO dosage, air flow, pH, and reaction time to identify the optimum operating conditions. Quadratic models for chemical oxygen demand (COD) and total organic carbon (TOC) removals prove to be significant with low probabilities (TOC removal rates of 99% and 74%, respectively. The TOC and COD removal rates correspond well with the predicted models. The maximum removal rate for TOC and COD was 99.3% and 76%, respectively at optimum operational conditions of TiO 2 dosage (0.5 g/L), ZnO dosage (0.54 g/L), air flow (4.3 L/min), reaction time (170 min) and pH (6.8). The new treatment process achieved higher degradation efficiencies for TOC and COD and reduced the treatment time comparing with other related processes.

  1. Improvement of COD and TOC reactive dyes in textile wastewater by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-07-06

    Jul 6, 2009 ... This study was designed to investigate the removal of reactive dyes, Samofix Red V-RBL and Samofix. Green V-G from wastewater using a two step Al (III) coagulation/activated carbon adsorption method. ... (90%) of chemical oxygen demand (COD), total organic carbon (TOC) ..... a liquid to a solid surface.

  2. Two-stage soil infiltration treatment system for treating ammonium wastewaters of low COD/TN ratios.

    Science.gov (United States)

    Lei, Zhongfang; Wu, Ting; Zhang, Yi; Liu, Xiang; Wan, Chunli; Lee, Duu-Jong; Tay, Joo-Hwa

    2013-01-01

    Soil infiltration treatment (SIT) is ineffective to treat ammonium wastewaters of total nitrogen (TN) > 100 mg l(-1). This study applied a novel two-stage SIT process for effective TN removal from wastewaters of TN>100 mg l(-1) and of chemical oxygen demand (COD)/TN ratio of 3.2-8.6. The wastewater was first fed into the soil column (stage 1) at hydraulic loading rate (HLR) of 0.06 m(3) m(-2) d(-1) for COD removal and total phosphorus (TP) immobilization. Then the effluent from stage 1 was fed individually into four soil columns (stage 2) at 0.02 m(3) m(-2) d(-1) of HLR with different proportions of raw wastewater as additional carbon source. Over the one-year field test, balanced nitrification and denitrification in the two-stage SIT revealed excellent TN removal (>90%) from the tested wastewaters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Removal of veterinary antibiotics from anaerobically digested swine wastewater using an intermittently aerated sequencing batch reactor.

    Science.gov (United States)

    Zheng, Wei; Zhang, Zhenya; Liu, Rui; Lei, Zhongfang

    2018-03-01

    A lab-scale intermittently aerated sequencing batch reactor (IASBR) was applied to treat anaerobically digested swine wastewater (ADSW) to explore the removal characteristics of veterinary antibiotics. The removal rates of 11 veterinary antibiotics in the reactor were investigated under different chemical organic demand (COD) volumetric loadings, solid retention times (SRT) and ratios of COD to total nitrogen (TN) or COD/TN. Both sludge sorption and biodegradation were found to be the major contributors to the removal of veterinary antibiotics. Mass balance analysis revealed that greater than 60% of antibiotics in the influent were biodegraded in the IASBR, whereas averagely 24% were adsorbed by sludge under the condition that sludge sorption gradually reached its equilibrium. Results showed that the removal of antibiotics was greatly influenced by chemical oxygen demand (COD) volumetric loadings, which could achieve up to 85.1%±1.4% at 0.17±0.041kgCOD/m -3 /day, while dropped to 75.9%±1.3% and 49.3%±12.1% when COD volumetric loading increased to 0.65±0.032 and 1.07±0.073kgCOD/m -3 /day, respectively. Tetracyclines, the dominant antibiotics in ADSW, were removed by 87.9% in total at the lowest COD loading, of which 30.4% were contributed by sludge sorption and 57.5% by biodegradation, respectively. In contrast, sulfonamides were removed about 96.2%, almost by biodegradation. Long SRT seemed to have little obvious impact on antibiotics removal, while a shorter SRT of 30-40day could reduce the accumulated amount of antibiotics and the balanced antibiotics sorption capacity of sludge. Influent COD/TN ratio was found not a key impact factor for veterinary antibiotics removal in this work. Copyright © 2017. Published by Elsevier B.V.

  4. PENURUNAN COD, TSS DAN TOTAL FOSFAT PADA SEPTIC TANK LIMBAH MATARAM CITRA SEMBADA CATERING DENGAN MENGGUNAKAN WASTEWATER GARDEN (Degradation of COD, TSS and Total Phosphate in Septic Tank Wastewater of Mataram Citra Sembada Catering Using Wastewater

    Directory of Open Access Journals (Sweden)

    Dradjat Suhardjo

    2008-07-01

    Full Text Available ABSTRAK  Sumber limbah berasal dari septictank industri restauran (catering Citra Sembada Catering, termasuk dalam kategori limbah domestik. Limbah tersebut banyak mengandung komponen yang tidak diinginkan bila dibuang ke badan air. Konsentrasi limbah yang masih di atas baku mutu, di antaranya akan memunculkan masalah pencemaran. Reaktor Wastewater Garden yang menggunakan krikil (0,5Cm-1cm dan 6 jenis tanaman yaitu : melati air (Echinodoras paleafias, Cyperus (Cyperus, Futoi (Hippochaetes lymnenalis, Pisang air (Typhonodorum indleyanum, Pickerel rush (Pontedoria cordata, Cattail (Typha latifulia. Penelitian ini bertujuan untuk mengetahui tingkat efektivitas reaktor Wastewater Garden, apabila digunakan untuk menurunkan konsentrasi Chemical Oxygen Demand (COD, Total Suspended Solid (TSS dan Fosfat Total sebagai faktor pencemar pada limbah industri restauran (Citra Sembada Catering yang tertampung pada septictank. Penelitian dilakukan dengan menggunakan reaktor Wastewater Garden dengan sistem batch dan dimensi reaktor lm x 0.5m x lm. Zona air limbah 75 cm, dan zona substrat atau krikil 80 cm, akar tanaman ditanam sedalam l0-15 cm. Metode penelitian yang digunakan berdasarkan SNI, di mana COD mengacu pada SNI 06-6989.2-2004 metode refluks tertutup secara spektrofotometri, TSS mengacu pada SK SNI M-03-1990-F metode pengujian secara gravimetri dan Fosfat total mengacu pada SNI M-52-1990-03 metode asam askorbat dengan alat spektrofotometer. Penelitian ini dilakukan selama 12 hari di mana setiap 3 hari sampel diambil pada outlel kemudian dianalisis. Berdasarkan hasil penelitian ini, diperoleh bahwa penggunaan wastewater garden pada limbah cair Mataram Citra Sembada Catering dapat menurunkan COD dengan efektivitas optimum 40,81% pada hari ke-6, penurunan TSS 89,l2% pada efektifitas optirnum hari ke-12 dan penurunan fosfat total dengan efektivitas optimum pada hari ke-6 yaitu sebesar 99,73 %. Tanaman dapat hidup dengan subur.   ABSTRACT  Wastewater

  5. Contaminant removal performances on domestic sewage using modified anoxic/anaerobic/oxic process and micro-electrolysis.

    Science.gov (United States)

    Zhou, Jun; Gao, Jingqing; Liu, Yifan; Xiao, Shuai; Zhang, Ruiqin; Zhang, Zhenya

    2013-01-01

    The objective of this study was to enhance removal of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) from domestic sewage in a sequencing batch reactor with added new materials. A modified anoxic/anaerobic/oxic (MAAO) process, integrating a micro-electrolysis (ME) bed in an anoxic tank, and complex biological media (CBM) in anoxic, anaerobic and oxic tanks to treat domestic sewage, and their performances were investigated. The MAAO system was operated at controlled hydraulic retention time (HRT) of 8 h and mixed liquor recirculation (MLR) at 75%. The results showed that the MAAO system could effectively remove COD, TN and TP with average rates of 93%, 80% and 94%, respectively, in March, and 94%, 76% and 91%, respectively, in August. In this system, TP was primarily removed from the anoxic tank regardless of the operational conditions; removal contribution ratios to TP of the anoxic tank reached 56% both in March and August, indicating that the ME bed can effectively enhance phosphorus removal. TN was primarily removed from the anoxic and anaerobic tanks; removal contribution ratios to TN of anoxic and anaerobic tanks reached 36-38% and 37-38%, respectively. The oxic tank had the highest share of COD removal (56% both in March and August) in the removal of phosphorus. The outflow concentrations of COD, TN and TP were 3-46, 7-14 and 0.3-0.5 mg/L, respectively, in March, and 26-49, 9-15 and 0.04-0.1 mg/L, respectively, in August. COD and TN removal performances indicated that the innovative materials of the ME bed and CBM can effectively enhance COD and TN removal.

  6. Electrically enhanced MBR system for total nutrient removal in remote northern applications.

    Science.gov (United States)

    Wei, V; Elektorowicz, M; Oleszkiewicz, J A

    2012-01-01

    Thousands of sparsely populated communities scatter in the remote areas of northern Canada. It is economically preferable to adopt the decentralized systems to treat the domestic wastewater because of the vast human inhabitant distribution and cold climatic conditions. Electro-technologies such as electrofiltration, elctrofloatation, electrocoagulation and electrokinetic separation have been applied in water and conventional wastewater treatment for decades due to the minimum requirements of chemicals as well as ease of operation. The membrane bioreactor (MBR) is gaining popularity in recent years as an alternative water/wastewater treatment technology. However, few studies have been conducted to hyphenate these two technologies. The purpose of this work is to design a novel electrically enhanced membrane bioreactor (EMBR) as an alternative decentralized wastewater treatment system with improved nutrient removal and reduced membrane fouling. Two identical submerged membranes (GE ZW-1 hollow fiber module) were used for the experiment, with one as a control. The EMBR and control MBR were operated for 4 months at room temperature (20 ± 2 °C) with synthetic feed and 2 months at 10 °C with real sewage. The following results were observed: (1) the transmembrane pressure (TMP) increased significantly more slowly in the EMBR and the interval between the cleaning cycles of the EMBR increased at least twice; (2) the dissolved chemical oxygen demand (COD) or total organic carbon (TOC) in the EMBR biomass was reduced from 30 to 51%, correspondingly, concentrations of the extracellular polymeric substances (EPS), the major suspicious membrane foulants, decreased by 26-46% in the EMBR; (3) both control and EMBR removed >99% of ammonium-N and >95% of dissolved COD, in addition, ortho-P removal in the EMBR was >90%, compared with 47-61% of ortho-P removal in the MBR; and (4) the advantage of the EMBR over the conventional MBR in terms of membrane fouling retardation and

  7. Occurrence of anisakid nematodes in Atlantic cod (Gadus morhua) and Greenland cod (Gadus ogac), West Greenland

    DEFF Research Database (Denmark)

    Mouritsen, Kim N.; Hedeholm, Rasmus; Schack, Henriette B.

    2010-01-01

    Anisakid nematodes commonly infect gadids, and are of economic and aesthetic importance to the commercial fishing industry in Greenland as some species are pathogenic to humans. However, very little is known about the occurrence of these parasites and their impact on the hosts in Greenland waters....... During a survey in 2005, stomach sample of 227 Atlantic cod (Gadus morhua) and 64 Greenland cod (Gadus ogac) was collected in Godthaab and Sisimiut fiord systems in West Greenland waters. All cod were dissected for stomach contents and anisakid nematodes were removed from the visceral cavity. Third stage...... nematode species regarding prevalence of infection and mean infection intensity was evident, and there was no relationship between fish condition and the intensity of nematode infections. Standardised for size, capelin-eating cod were in better condition and more heavily infected than fish subsisting...

  8. Replacement of chemical oxygen demand (COD) with total organic carbon (TOC) for monitoring wastewater treatment performance to minimize disposal of toxic analytical waste.

    Science.gov (United States)

    Dubber, Donata; Gray, Nicholas F

    2010-10-01

    Chemical oxygen demand (COD) is widely used for wastewater monitoring, design, modeling and plant operational analysis. However this method results in the production of hazardous wastes including mercury and hexavalent chromium. The study examined the replacement of COD with total organic carbon (TOC) for general performance monitoring by comparing their relationship with influent and effluent samples from 11 wastewater treatment plants. Biochemical oxygen demand (BOD5) was also included in the comparison as a control. The results show significant linear relationships between TOC, COD and BOD5 in settled (influent) domestic and municipal wastewaters, but only between COD and TOC in treated effluents. The study concludes that TOC can be reliably used for the generic replacement of both COD (COD=49.2+3.00*TOC) and BOD5 (BOD5=23.7+1.68*TOC) in influent wastewaters but only for COD (COD=7.25+2.99*TOC) in final effluents.

  9. Constructed wetland using corncob charcoal substrate: pollutants removal and intensification.

    Science.gov (United States)

    Liu, Mao; Li, Boyuan; Xue, Yingwen; Wang, Hongyu; Yang, Kai

    2017-09-01

    To investigate the feasibility of using corncob charcoal substrate in constructed wetlands, four laboratory-scale vertical flow constructed wetlands (VFCWs) were built. Effluent pollutant (chemical oxygen demand (COD), NH 4 + -N, total phosphorus (TP)) concentrations during the experiment were determined to reveal pollutant removal mechanisms and efficiencies at different stages. In the stable stage, a VFCW using clay ceramisite substrate under aeration attained higher COD (95.1%), and NH 4 + -N (95.1%) removal efficiencies than a VFCW using corncob charcoal substrate (91.5% COD, 91.3% NH 4 + -N) under aeration, but lower TP removal efficiency (clay ceramisite 32.0% and corncob charcoal 40.0%). The VFCW with raw corncob substrate showed stronger COD emissions (maximum concentration 3,108 mg/L) than the corncob charcoal substrate (COD was lower than influent). The VFCW using corncob charcoal substrate performed much better than the VFCW using clay ceramisite substrate under aeration when the C/N ratio was low (C/N = 1.5, TN removal efficiency 36.89%, 4.1% respectively). These results suggest that corncob charcoal is a potential substrate in VFCWs under aeration with a unique self -supplying carbon source property in the denitrification process.

  10. Characterization and removal of specific organic constituents in an UASB-trickling-filter system treating domestic wastewater.

    Science.gov (United States)

    Pontes, Patrícia Procópio; Chernicharo, Carlos Augusto de Lemos

    2011-01-01

    This paper presents the characterization of specific organic constituents (carbohydrates, proteins and lipids) in raw sewage and in the anaerobic and aerobic effluents of a demo-scale (500 inhabitants) UASB- trickling-filter system. The evaluation of such parameters was carried out for two operating conditions, either without sludge recirculation (experiment I) from the trickling filter to the UASB reactor or with sludge recirculation (experiment II), for sludge thickening and stabilization, in the anaerobic reactor. The results showed that the contribution of acetic acid, carbohydrates, proteins and lipids amounted for approximately 70% of the total COD fed to the UASB during experiment I, whereas during experiment II these constituents amounted for only around 40% of the total COD. Although very high BOD and COD overall removal efficiencies were observed for the treatment system (around 90% and 80%, respectively), it was possible to infer that these efficiencies were mainly related to the removal of carbohydrates and lipids (around 80% removal), and of other non-identified constituents. The removal of proteins was much lower (around 50% removal), and the relative contribution of proteins to the total COD increased along the treatment course, being responsible for most of the residual COD of the treatment units. In the present system configuration, the UASB reactor played a major role in the removal of carbohydrates, whereas the trickling filter was very effective in the removal of lipids. The return of aerobic sludge for thickening and stabilization in the UASB reactor did not affect its performance.

  11. Nutrients removal in hybrid fluidised bed bioreactors operated with aeration cycles.

    Science.gov (United States)

    Martin, Martin; Enríquez, L López; Fernández-Polanco, M; Villaverde, S; Garcia-Encina, P A

    2007-01-01

    Abstract Two hybrid fluidised bed reactors filled with sepiolite and granular activated carbon (GAC) were operated with short cycled aeration for removing organic matter, total nitrogen and phosphorous, respectively. Both reactors were continuously operated with synthetic and/or industrial wastewater containing 350-500 mg COD/L, 110-130 mg NKT/L, 90-100 mg NH3-N/L and 12-15 mg P/L for 8 months. The reactor filled with sepiolite, treating only synthetic wastewater, removed COD, ammonia, total nitrogen and phosphorous up to 88, 91, 55 and 80% with a hydraulic retention time (HRT) of 10 h, respectively. These efficiencies correspond to removal rates of 0.95 kgCODm(-3)d(-1) and 0.16 kg total N m(-3)d(-1). The reactor filled with GAC was operated for 4 months with synthetic wastewater and 4 months with industrial wastewater, removing 98% of COD, 96% of ammonia, and 66% of total nitrogen, with an HRT of 13.6 h. No significant phosphorous removing activity was observed in this reactor. Microbial communities growing with both reactors were followed using polymerase chain reaction (PCR) and denaturing gradient gel electrophoresis (DGGE) techniques. The microbial fingerprints, i.e. DGGE profiles, indicated that biological communities in both reactors were stable along the operational period even when the operating conditions were changed.

  12. Artificial intelligence based model for optimization of COD removal efficiency of an up-flow anaerobic sludge blanket reactor in the saline wastewater treatment.

    Science.gov (United States)

    Picos-Benítez, Alain R; López-Hincapié, Juan D; Chávez-Ramírez, Abraham U; Rodríguez-García, Adrián

    2017-03-01

    The complex non-linear behavior presented in the biological treatment of wastewater requires an accurate model to predict the system performance. This study evaluates the effectiveness of an artificial intelligence (AI) model, based on the combination of artificial neural networks (ANNs) and genetic algorithms (GAs), to find the optimum performance of an up-flow anaerobic sludge blanket reactor (UASB) for saline wastewater treatment. Chemical oxygen demand (COD) removal was predicted using conductivity, organic loading rate (OLR) and temperature as input variables. The ANN model was built from experimental data and performance was assessed through the maximum mean absolute percentage error (= 9.226%) computed from the measured and model predicted values of the COD. Accordingly, the ANN model was used as a fitness function in a GA to find the best operational condition. In the worst case scenario (low energy requirements, high OLR usage and high salinity) this model guaranteed COD removal efficiency values above 70%. This result is consistent and was validated experimentally, confirming that this ANN-GA model can be used as a tool to achieve the best performance of a UASB reactor with the minimum requirement of energy for saline wastewater treatment.

  13. Enhanced removal of chemical oxygen demand, nitrogen and phosphorus using the ameliorative anoxic/anaerobic/oxic process and micro-electrolysis.

    Science.gov (United States)

    Bao, K Q; Gao, J Q; Wang, Z B; Zhang, R Q; Zhang, Z Y; Sugiura, N

    2012-01-01

    Synthetic wastewater was treated using a novel system integrating the reversed anoxic/anaerobic/oxic (RAAO) process, a micro-electrolysis (ME) bed and complex biological media. The system showed superior chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal rates. Performance of the system was optimised by considering the influences of three major controlling factors, namely, hydraulic retention time (HRT), organic loading rate (OLR) and mixed liquor recirculation (MLR). TP removal efficiencies were 69, 87, 87 and 83% under the HRTs of 4, 8, 12 and 16 h. In contrast, HRT had negligible effects on the COD and TN removal efficiencies. COD, TN and TP removal efficiencies from synthetic wastewater were 95, 63 and 87%, respectively, at an OLR of 1.9 g/(L·d). The concentrations of COD, TN and TP in the effluent were less than 50, 15 and 1 mg/L, respectively, at the controlled MLR range of 75-100%. In this system, organics, TN and TP were primarily removed from anoxic tank regardless of the operational conditions.

  14. Removal of carbon, nitrogen and phosphorus from the separated liquid phase of hog manure by the multi-zone BioCAST technology.

    Science.gov (United States)

    Yerushalmi, Laleh; Alimahmoodi, Mahmood; Afroze, Niema; Godbout, Stephane; Mulligan, Catherine N

    2013-06-15

    The removal of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) at concentrations of 960 ± 38 to 2400 ± 96 mg/L, 143 ± 9 to 235 ± 15 mg/L and 25 ± 2 to 57 ± 4 mg/L, respectively, from the separated liquid phase of hog manure by the multi-zone BioCAST technology is discussed. Despite the inhibitory effect of hog waste toward microbial activities, removal efficiencies up to 89.2% for COD, 69.2% for TN and 47.6% for TP were obtained during 185 d of continuous operation. The free ammonia inhibition was postulated to be responsible for the steady reduction of COD and TP removal with the increase of TN/TP ratio from 3.6 to 5.8. On the contrary, the increase of COD/TN ratio from 4.8 to 14.1 improved the removal of all contaminants. Nitrogen removal did not show any dependence on the COD/TP ratio, despite the steady increase of COD and TP removal with this ratio in the range of 19.3-50.6. The removal efficiencies of organic and inorganic contaminants increased progressively owing to the adaptation of microbial biomass, resulting from the presence of suspended biomass in the mixed liquor that circulated continuously between the three zones of aerobic, microaerophilic and anoxic, as well as the attached biomass immobilized inside the aerobic zone. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Cycle length and COD/N ratio determine properties of aerobic granules treating high-nitrogen wastewater.

    Science.gov (United States)

    Cydzik-Kwiatkowska, Agnieszka; Bernat, Katarzyna; Zielińska, Magdalena; Wojnowska-Baryła, Irena

    2014-07-01

    Aerobic granule characteristic in sequencing batch reactors treating high-nitrogen digester supernatant was investigated at cycle lengths (t) of 6, 8 and 12 h with the COD/N ratios in the influent of 4.5 and 2.3. The biomass production (Y obs) correlated with the extracellular polymeric substances (EPS) in grams per COD removed. Denitrification efficiency significantly decreased as the amount of EPS in biomass increased, suggesting that organic assimilation in EPS hampers nitrogen removal. Granule hydrophobicity was highest at t of 8 h; the t has to be long enough to remove pollutants, but not so long that excessive biomass starvation causes extracellular protein consumption that decreases hydrophobicity. At a given t, reducing the COD/N ratio improved hydrophobicity that stimulates cell aggregation. At t of 6 h and the COD/N ratio of 2.3, the dominance of 0.5-1.0 mm granules favored simultaneous nitrification and denitrification and resulted in the highest nitrogen removal.

  16. Anaerobic treatment of antibiotic production wastewater pretreated with enhanced hydrolysis: Simultaneous reduction of COD and ARGs.

    Science.gov (United States)

    Yi, Qizhen; Zhang, Yu; Gao, Yingxin; Tian, Zhe; Yang, Min

    2017-03-01

    The presence of high concentration antibiotics in wastewater can disturb the stability of biological wastewater treatment systems and promote generation of antibiotic resistance genes (ARGs) during the treatment. To solve this problem, a pilot system consisting of enhanced hydrolysis pretreatment and an up-flow anaerobic sludge bed (UASB) reactor in succession was constructed for treating oxytetracycline production wastewater, and the performance was evaluated in a pharmaceutical factory in comparison with a full-scale anaerobic system operated in parallel. After enhanced hydrolysis under conditions of pH 7 and 85 °C for 6 h, oxytetracycline production wastewater with an influent chemical oxygen demand (COD) of 11,086 ± 602 mg L -1 was directly introduced into the pilot UASB reactor. With the effective removal of oxytetracycline and its antibacterial potency (from 874 mg L -1 to less than 0.61 mg L -1 and from 900 mg L -1 to less than 0.84 mg L -1 , respectively) by the enhanced hydrolysis pretreatment, an average COD removal rate of 83.2%, 78.5% and 68.9% was achieved at an organic loading rate of 3.3, 4.8 and 5.9 kg COD m -3  d -1 , respectively. At the same time, the relative abundances of the total tetracycline (tet) genes and a mobile element (Class 1 integron (intI1)) in anaerobic sludge on day 96 were one order of magnitude lower than those in inoculated sludge on day 0 (P anaerobic system treating oxytetracycline production wastewater with an influent COD of 3720 ± 128 mg L -1 after dilution exhibited a COD removal of 51 ± 4% at an organic loading rate (OLR) 1.2 ± 0.2 kg m -3  d -1 , and a total tet gene abundance in sludge was five times higher than the pilot-scale system (P anaerobic treatment of oxytetracycline production wastewater containing high concentrations of oxytetracycline with significantly lower generation of ARGs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Microbial monitoring of ammonia removal in a UASB reactor treating pre-digested chicken manure with anaerobic granular inoculum.

    Science.gov (United States)

    Yangin-Gomec, Cigdem; Pekyavas, Goksen; Sapmaz, Tugba; Aydin, Sevcan; Ince, Bahar; Akyol, Çağrı; Ince, Orhan

    2017-10-01

    Performance and microbial community dynamics in an upflow anaerobic sludge bed (UASB) reactor coupled with anaerobic ammonium oxidizing (Anammox) treating diluted chicken manure digestate (Total ammonia nitrogen; TAN=123±10mg/L) were investigated for a 120-d operating period in the presence of anaerobic granular inoculum. Maximum TAN removal efficiency reached to above 80% with as low as 20mg/L TAN concentrations in the effluent. Moreover, total COD (tCOD) with 807±215mg/L in the influent was removed by 60-80%. High-throughput sequencing revealed that Proteobacteria, Actinobacteria, and Firmicutes were dominant phyla followed by Euryarchaeota and Bacteroidetes. The relative abundance of Planctomycetes significantly increased from 4% to 8-9% during the late days of the operation with decreased tCOD concentration, which indicated a more optimum condition to favor ammonia removal through anammox route. There was also significant association between the hzsA gene and ammonia removal in the UASB reactor. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Application of response surface methodology (RSM) for optimisation of COD, NH3-N and 2,4-DCP removal from recycled paper wastewater in a pilot-scale granular activated carbon sequencing batch biofilm reactor (GAC-SBBR).

    Science.gov (United States)

    Muhamad, Mohd Hafizuddin; Sheikh Abdullah, Siti Rozaimah; Mohamad, Abu Bakar; Abdul Rahman, Rakmi; Hasan Kadhum, Abdul Amir

    2013-05-30

    In this study, the potential of a pilot-scale granular activated carbon sequencing batch biofilm reactor (GAC-SBBR) for removing chemical oxygen demand (COD), ammoniacal nitrogen (NH3-N) and 2,4-dichlorophenol (2,4-DCP) from recycled paper wastewater was assessed. For this purpose, the response surface methodology (RSM) was employed, using a central composite face-centred design (CCFD), to optimise three of the most important operating variables, i.e., hydraulic retention time (HRT), aeration rate (AR) and influent feed concentration (IFC), in the pilot-scale GAC-SBBR process for recycled paper wastewater treatment. Quadratic models were developed for the response variables, i.e., COD, NH3-N and 2,4-DCP removal, based on the high value (>0.9) of the coefficient of determination (R(2)) obtained from the analysis of variance (ANOVA). The optimal conditions were established at 750 mg COD/L IFC, 3.2 m(3)/min AR and 1 day HRT, corresponding to predicted COD, NH3-N and 2,4-DCP removal percentages of 94.8, 100 and 80.9%, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Performance of denitrifying microbial fuel cell subjected to variation in pH, COD concentration and external resistance.

    Science.gov (United States)

    Li, Jin-Tao; Zhang, Shao-Hui; Hua, Yu-Mei

    2013-01-01

    The effects of pH, chemical oxygen demand (COD) concentration and external resistance on denitrifying microbial fuel cell were evaluated in terms of electricity generation characteristics and pollutant removal performance. The results showed that anodic influent with weakly alkaline or neutral pH and cathodic influent with weakly acidic pH favored pollutant removal and electricity generation. The suitable influent pH of the anode and cathode were found to be 7.5-8.0 and 6.0-6.5, respectively. In the presence of sufficient nitrate in the cathode, higher influent COD concentration led to more electricity generation and greater pollutant removal rates. With an anodic influent pH of 8.0 and a cathodic influent pH of 6.0, an influent COD concentration of 400 mg/L was deemed to be appropriate. Low external resistance favored nitrate and COD removal. The results suggest that operation of denitrifying microbial fuel cell at a lower external resistance would be desirable for pollutant removal but not electricity generation.

  20. Effect of powdered activated carbon technology on short-cut nitrogen removal for coal gasification wastewater.

    Science.gov (United States)

    Zhao, Qian; Han, Hongjun; Xu, Chunyan; Zhuang, Haifeng; Fang, Fang; Zhang, Linghan

    2013-08-01

    A combined process consisting of a powdered activated carbon technology (PACT) and short-cut biological nitrogen removal reactor (SBNR) was developed to enhance the removal efficiency of the total nitrogen (TN) from the effluent of an upflow anaerobic sludge bed (UASB) reactor, which was used to treat coal gasification wastewater (CGW). The SBNR performance was improved with the increasing of COD and TP removal efficiency via PACT. The average removal efficiencies of COD and TP in PACT were respectively 85.80% and 90.30%. Meanwhile, the NH3-N to NO2-N conversion rate was achieved 86.89% in SBNR and the total nitrogen (TN) removal efficiency was 75.54%. In contrast, the AOB in SBNR was significantly inhibited without PACT or with poor performance of PACT in advance, which rendered the removal of TN. Furthermore, PAC was demonstrated to remove some refractory compounds, which therefore improved the biodegradability of the coal gasification wastewater. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Effect of influent COD/SO4(2-) ratios on biodegradation behaviors of starch wastewater in an upflow anaerobic sludge blanket (UASB) reactor.

    Science.gov (United States)

    Lu, Xueqin; Zhen, Guangyin; Ni, Jialing; Hojo, Toshimasa; Kubota, Kengo; Li, Yu-You

    2016-08-01

    A lab-scale upflow anaerobic sludge blanket (UASB) has been run for 250days to investigate the influence of influent COD/SO4(2-) ratios on the biodegradation behavior of starch wastewater and process performance. Stepwise decreasing COD/SO4(2-) ratio enhanced sulfidogenesis, complicating starch degradation routes and improving process stability. The reactor exhibited satisfactory performance at a wide COD/SO4(2-) range ⩾2, attaining stable biogas production of 1.15-1.17LL(-1)d(-1) with efficient simultaneous removal of total COD (73.5-80.3%) and sulfate (82.6±6.4%). Adding sulfate favored sulfidogenesis process and diversified microbial community, invoking hydrolysis-acidification of starch and propionate degradation and subsequent acetoclastic methanogenesis; whereas excessively enhanced sulfidogenesis (COD/SO4(2-) ratios UASB technology in water industry from basic science. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Organics removal of combined wastewater through shallow soil infiltration treatment: a field and laboratory study.

    Science.gov (United States)

    Zhang, Zhiyin; Lei, Zhongfang; Zhang, Zhenya; Sugiura, Norio; Xu, Xiaotian; Yin, Didi

    2007-11-19

    Soil infiltration treatment (SIT) was proved to be an effective and low-cost treatment technique for decentralized effluents in the areas without perfect sewage systems. Field-scale experiments were conducted under several conditions to assess organics removals through a shallow soil infiltration treatment (SSIT, with effective depth 0.3m) of combined wastewater (discharge from toilets, restaurants and a gas station), while bench-scale soil column experiments were performed in laboratory in parallel to investigate biological and abiological effects of this kind of system. From the start-up to the 10th month, the field SSIT trenches experienced the lowest and highest temperatures of the operation period in Shanghai and exhibited effective organics removals after maturation, with the highest removal rate 75.8% of chemical oxygen demand (COD), highest ultraviolet absorption at 254 nm (UV(254)) decrease by 67.2% and 35.2-100% removals of phenolic and phthalate pollutants. The laboratory results indicated that more organics could be removed in room-temperatured (25+/-2 degrees C) SSIT systems under different influent COD concentrations from 45 mg/l to 406 mg/l, and the highest total COD removal rate could reach 94.0%, in which biological effect accounted for 57.7-71.9%. The results showed that temperature and hydraulic loading rate were the most important factors influencing the removals of COD and organic pollutants in SSIT.

  3. Achieving low effluent NO3-N and TN concentrations in low influent chemical oxygen demand (COD) to total Kjeldahl nitrogen (TKN) ratio without using external carbon source

    Science.gov (United States)

    Cao, Jiashun; Oleyiblo, Oloche James; Xue, Zhaoxia; Otache, Y. Martins; Feng, Qian

    2015-07-01

    Two mathematical models were used to optimize the performance of a full-scale biological nutrient removal (BNR) activated treatment plant, a plug-flow bioreactors operated in a 3-stage phoredox process configuration, anaerobic anoxic oxic (A2/O). The ASM2d implemented on the platform of WEST2011 software and the BioWin activated sludge/anaerobic digestion (AS/AD) models were used in this study with the aim of consistently achieving the designed effluent criteria at a low operational cost. Four ASM2d parameters (the reduction factor for denitrification , the maximum growth rate of heterotrophs (µH), the rate constant for stored polyphosphates in PAOs ( q pp), and the hydrolysis rate constant ( k h)) were adjusted. Whereas three BioWin parameters (aerobic decay rate ( b H), heterotrophic dissolved oxygen (DO) half saturation ( K OA), and Y P/acetic) were adjusted. Calibration of the two models was successful; both models have average relative deviations (ARD) less than 10% for all the output variables. Low effluent concentrations of nitrate nitrogen (N-NO3), total nitrogen (TN), and total phosphorus (TP) were achieved in a full-scale BNR treatment plant having low influent chemical oxygen demand (COD) to total Kjeldahl nitrogen (TKN) ratio (COD/TKN). The effluent total nitrogen and nitrate nitrogen concentrations were improved by 50% and energy consumption was reduced by approximately 25%, which was accomplished by converting the two-pass aerobic compartment of the plug-flow bioreactor to anoxic reactors and being operated in an alternating mode. Findings in this work are helpful in improving the operation of wastewater treatment plant while eliminating the cost of external carbon source and reducing energy consumption.

  4. Association between nematode Hysterothylacium aduncum invasion of cod larvae and growth

    DEFF Research Database (Denmark)

    Mehrdana, Foojan; Bahlool, Qusay Z. M.; Kuhn, Jesper

    , lapillus otoliths were removed, polished and the number of growth zones in each otolith counted by light microscopy. Each growth zone indicates one day of the fish life span. Covariance analysis demonstrated highly significant differences (p≤ 0.001) between the growth rate of infected and uninfected cod...... invertebrates and fish species and for some species also higher vertebrate hosts. We have recently demonstrated that fry of North Sea cod has a high prevalence of infection with regard to the nematode Hysterothylacium aduncum and it was indicated that these infections could affect survival of cod and thereby...... affect the cod stock in the North Sea. The objective of the present study was to elucidate if infections are associated with a decrease or an increase of fish size when examining fish of the same age. We investigated effects of H. aduncum infections on the growth rate of cod larvae by using the otolith...

  5. Cod Liver Oil

    Science.gov (United States)

    Cod liver oil can be obtained from eating fresh cod liver or by taking supplements. Cod liver oil is used as a source of vitamin A ... called macular degeneration. Some people put cod liver oil on their skin to speed healing of wounds, ...

  6. The Effect of COD Concentration Containing Leaves Litter, Canteen and Composite Waste to the Performance of Solid Phase Microbial Fuel Cell (SMFC)

    Science.gov (United States)

    Samudro, Ganjar; Syafrudin; Nugraha, Winardi Dwi; Sutrisno, Endro; Priyambada, Ika Bagus; Muthi'ah, Hilma; Sinaga, Glory Natalia; Hakiem, Rahmat Tubagus

    2018-02-01

    This research is conducted to analyze and determine the optimum of COD concentration containing leaves litter, canteen and composite waste to power density and COD removal efficiency as the indicator of SMFC performance. COD as the one of organic matter parameters perform as substrate, nutrient and dominating the whole process of SMFC. Leaves litter and canteen based food waste were obtained from TPST UNDIP in Semarang and treated in SMFC reactor. Its reactor was designed 2 liter volume and equipped by homemade graphene electrodes that were utilized at the surface of organic waste as cathode and in a half of reactor height as anode. COD concentration was initially characterized and became variations of initial COD concentration. Waste volume was maintained 2/3 of volume of reactor. Bacteria sources as the important process factor in SMFC were obtained from river sediment which contain bacteroides and exoelectrogenic bacteria. Temperature and pH were not maintained while power density and COD concentration were periodically observed and measured during 44 days. The results showed that power density up to 4 mW/m2 and COD removal efficiency performance up to 70% were reached by leaves litter, canteen and composite waste at days 11 up to days 44 days. Leaves litter contain 16,567 mg COD/l providing higher COD removal efficiency reached approximately 87.67%, more stable power density reached approximately 4.71 mW/m2, and faster optimum time in the third day than canteen based food waste and composite waste. High COD removal efficiency has not yet resulted in high power density.

  7. Comparison of recirculation configurations for biological nutrient removal in a membrane bioreactor.

    Science.gov (United States)

    Bekir Ersu, Cagatayhan; Ong, Say Kee; Arslankaya, Ertan; Brown, Patrick

    2008-03-01

    A 12-L lab-scale membrane bioreactor (MBR), consisting of an anaerobic and anoxic compartment followed by an oxic plate-frame membrane compartment, was evaluated for carbonaceous and nutrient removals by varying the recirculation of mixed liquor and permeate. The hydraulic retention times (HRTs) for the anaerobic, anoxic, and oxic compartments were 2, 2, and 8h, respectively. The solids residence time (SRT) for the oxic compartment was 25 days. Five different recirculation configurations were tested by recirculating mixed liquor and/or permeate recirculation equal to the influent flow rate (identified as 100%) into different locations of the anaerobic and anoxic compartments. Of the five configurations, the configuration with 100% mixed liquor recirculation to the anaerobic compartment and 100% permeate recirculation to the anoxic compartment gave the highest percentage removal with an average 92.3+/-0.5% soluble chemical oxygen demand (sCOD), 75.6+/-0.4% total nitrogen (TN), and 62.4+/-1.3% total phosphorus (TP) removal. When the mixed liquor and permeate recirculation rates were varied for the same configuration, the highest TP removal was obtained for 300% mixed liquor recirculation and 100% permeate recirculation (300%/100%) with a TP removal of 88.1+/-1.3% while the highest TN removal (90.3+/-0.3%) was obtained for 200%/300% recirculation. TN and TP concentrations as low as 4.2+/-0.1 and 1.4+/-0.2mg/L respectively were obtained. Mass loading rates were generally low in the range of 0.11-0.22kgCOD/kgMLSS/d due to high biomass concentrations within the oxic reactor (approx. 8000mg/L). The BioWin model was calibrated against one set of the experimental data and was found to predict the experimental data of effluent TN, TP, and NO(3)(-)-N but over-predicted sCOD and NH(3)-N for various recirculation rates. The anoxic heterotrophic yield for the calibrated model was 0.2kg biomass COD/kg COD utilized while the maximum growth rates were found to be 0.45day(-1) for mu

  8. Clofibric acid and gemfibrozil removal in membrane bioreactors.

    Science.gov (United States)

    Gutierrez-Macias, Tania; Nacheva, Petia Mijaylova

    2015-01-01

    The removal of two blood lipid regulators, clofibric acid (CLA) and gemfibrozil (GFZ), was evaluated using two identical aerobic membrane bioreactors with 6.5 L effective volume each. Polysulfone ultrafiltration hollow fiber membranes were submerged in the reactors. Different operating conditions were tested varying the organic load (F/M), hydraulic residence time (HRT), biomass concentration measured as total suspended solids in the mixed liquor (MLTSS) and the sludge retention time (SRT). Complete GFZ removal was obtained with F/M of 0.21-0.48 kg COD kgTSS⁻¹ d⁻¹, HRT of 4-10 hours, SRT of 10-32 d and MLTSS of 6-10 g L⁻¹. The GFZ removal can be attributed to biodegradation and there was no accumulation of the compound in the biomass. The CLA removals improved with the SRT and HRT increase and F/M decrease. Average removals of 78-79% were obtained with SRT 16-32 d, F/M of 0.21-0.34 kgCOD kgTSS⁻¹ d⁻¹, HRT of 7-10 hours and MLTSS of 6-10 g L⁻¹. Biodegradation was found to be the main removal pathway.

  9. Effect of the two-stage thermal disintegration and anaerobic digestion of sewage sludge on the COD fractions

    Directory of Open Access Journals (Sweden)

    Ciaciuch Anna

    2017-09-01

    Full Text Available The research presents the changes in chemical oxygen demand (COD fractions during the two-stage thermal disintegration and anaerobic digestion (AD of sewage sludge in municipal wastewater treatment plant (WWTP. Four COD fractions have been separated taking into account the solubility of substrates and their susceptibility to biodegradation: inert soluble organic matter SI, readily biodegradable substrate SS, slowly biodegradable substrates XS and inert particulate organic material XI. The results showed that readily biodegradable substrates SS (46.8% of total COD and slowly biodegradable substrates XS (36.1% of total COD were dominant in the raw sludge effluents. In sewage effluents after two-stage thermal disintegration, the percentage of SS fraction increased to 90% of total COD and percentage of XS fraction decreased to 8% of total COD. After AD, percentage of SS fraction in total COD decreased to 64%, whereas the percentage of other fractions in effluents increased.

  10. A study of lipid- and water-soluble arsenic species in liver of Northeast Arctic cod (Gadus morhua) containing high levels of total arsenic

    DEFF Research Database (Denmark)

    Sele, Veronika; Sloth, Jens Jørgen; Julshamn, Kale

    2015-01-01

    In the present study liver samples (n = 26) of Northeast Arctic cod (Gadus morhua), ranging in total arsenic concentrations from 2.1 to 240 mg/kg liver wet weight (ww), were analysed for their content of total arsenic and arsenic species in the lipid-soluble and water-soluble fractions. The arsen...

  11. Enhancing organic matter removal, biopolymer recovery and electricity generation from distillery wastewater by combining fungal fermentation and microbial fuel cell.

    Science.gov (United States)

    Ghosh Ray, S; Ghangrekar, M M

    2015-01-01

    For enhancing organic matter removal from cereal-based distillery stillage two-stage treatment consisting of fermentation by Aspergillus awamori followed by microbial fuel cell (MFC) is proposed. Considerable reduction in total and soluble chemical oxygen demand (COD) up to 70% and 40%, respectively, along with 98% reduction of suspended solids (SS) has been achieved during fungal pretreatment. The process generated chitosan, a useful fermentation byproduct from fungal mycelia, as 0.6-0.7g/l of settled sludge with mycelium (3.8% solids). Prior treatment of wastewater with fungal strain enhanced the power generation in MFC by 2.9 times at an organic loading rate of 1.5kgCOD/m(3)day, demonstrating soluble COD reduction of 92% in MFC. While treating distillery wastewater, this two-stage integrated biological process demonstrated overall 99% COD removal and almost complete removal of SS, delivering ample scope for scale-up and industrial application to offer effective solution for distillery wastewater treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Removal of nitrogen and organic matter in a submerged-membrane bioreactor operating in a condition of simultaneous nitrification and denitrification

    Directory of Open Access Journals (Sweden)

    Izabela Major Barbosa

    2016-04-01

    Full Text Available This study evaluated the removal of nitrogen and organic matter in a membrane bioreactor system operating in a condition of simultaneous nitrification and denitrification controlled by intermittent aeration. A submerged-membrane system in a bioreactor was used in a pilot scale to treat domestic wastewater. The dissolved oxygen concentration was maintained between 0.5 and 0.8 mg L-1. The concentration of the mixed liquor suspended solids (MLSS in the system ranged from 1 to 6 g L-1. The system efficiency was evaluated by the removal efficiency of organic matter, quantified by Chemical Oxygen Demand (COD, Biochemical Oxygen Demand (BOD5 and Total Organic Carbon (TOC. Nitrogen removal was assessed by quantifying Total Kjeldahl Nitrogen (TKN and ammonia nitrogen. During the system start-up, the removal efficiencies of COD and NTK were around 90% and 80%, respectively. After the simultaneous nitrification and denitrification (SND conditions were established, the removal efficiencies of COD and NTK were 70% and 99%, respectively. These results showed that sewage treatment with the membrane bioreactor (MBR system, operating with simultaneous nitrification and denitrification conditions, was able to remove organic matter and promote nitrification and denitrification in a single reactor, producing a high-quality permeate.

  13. Enhanced energy recovery from cassava ethanol wastewater through sequential dark hydrogen, photo hydrogen and methane fermentation combined with ammonium removal.

    Science.gov (United States)

    Lin, Richen; Cheng, Jun; Yang, Zongbo; Ding, Lingkan; Zhang, Jiabei; Zhou, Junhu; Cen, Kefa

    2016-08-01

    Cassava ethanol wastewater (CEW) was subjected to sequential dark H2, photo H2 and CH4 fermentation to maximize H2 production and energy yield. A relatively low H2 yield of 23.6mL/g soluble chemical oxygen demand (CODs) was obtained in dark fermentation. To eliminate the inhibition of excessive NH4(+) on sequential photo fermentation, zeolite was used to remove NH4(+) in residual dark solution (86.5% removal efficiency). The treated solution from 5gCODs/L of CEW achieved the highest photo H2 yield of 369.7mL/gCODs, while the solution from 20gCODs/L gave the lowest yield of 259.6mL/gCODs. This can be explained that photo H2 yield was correlated to soluble metabolic products (SMPs) yield in dark fermentation, and specific SMPs yield decreased from 38.0 to 18.1mM/g CODs. The total energy yield significantly increased to 8.39kJ/gCODs by combining methanogenesis with a CH4 yield of 117.9mL/gCODs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Eficiência do reator seqüencial em batelada (RSB na remoção de nitrogênio no tratamento de esgoto doméstico com DQO baixa The sequencing batch reactor (SBR efficiency in the removal of nitrogen on the treatment of domestic sewage with low COD

    Directory of Open Access Journals (Sweden)

    Luiz Fernando de Abreu Cybis

    2004-09-01

    Full Text Available Este trabalho tem como objetivo avaliar a eficiência e a estabilidade do RSB na remoção de nitrogênio no tratamento de esgoto doméstico com DQO baixa. O reator utilizado no experimento possui volume de trabalho de 600 L e trata 1200 L/d de esgoto bruto em três bateladas de oito horas. A partir dos dados obtidos na pesquisa, observou-se que o reator seqüencial em batelada possibilitou a remoção média de nitrogênio total igual a 88 % no tratamento de esgoto doméstico com DQO média de 257 mg/L. A remoção de DQO foi de 90 %, a média da alcalinidade total no efluente foi 72 mgCaCO3/L e o índice volumétrico de lodo médio ficou em 86 mL/g. Estes resultados indicam que é possível utilizar RSB para o tratamento de esgoto doméstico com matéria orgânica reduzida sem comprometer a qualidade do efluente, a remoção de nitrogênio e a estabilidade operacional do sistema.This work had the objective of evaluating the SBR efficiency and stability in the removal of nitrogen on the treatment of domestic sewage with low COD. The reactor used in the experiment has a working volume of 600 L, and treats 1200 L/d of raw sewage in three 8-hour cycles. From the data gathered during the research, it was realized that the SBR fostered an average removal of total nitrogen equal to 88% in the treatment of a domestic sewage with an average COD of 257 mg/L. The COD removal was 90%, the final effluent total alkalinity was 72 mgCaCO3/L, and the sludge volumetric index was 86 mL/g. The results indicate that is possible to use SBR for the treatment of domestic sewage with low organic matter without compromising the final effluent quality, the nitrogen removal ability, and the stability of the system.

  15. COD fractions of leachate from aerobic and anaerobic pilot scale landfill reactors

    International Nuclear Information System (INIS)

    Bilgili, M. Sinan; Demir, Ahmet; Akkaya, Ebru; Ozkaya, Bestamin

    2008-01-01

    One of the most important problems with designing and maintaining a landfill is managing leachate that generated when water passes through the waste. In this study, leachate samples taken from aerobic and anaerobic landfill reactors operated with and without leachate recirculation are investigated in terms of biodegradable and non-biodegradable fractions of COD. The operation time is 600 days for anaerobic reactors and 250 days for aerobic reactors. Results of this study show that while the values of soluble inert COD to total COD in the leachate of aerobic landfill with leachate recirculation and aerobic dry reactors are determined around 40%, this rate was found around 30% in the leachate of anaerobic landfill with leachate recirculation and traditional landfill reactors. The reason for this difference is that the aerobic reactors generated much more microbial products. Because of this condition, it can be concluded that total inert COD/total COD ratios of the aerobic reactors were 60%, whereas those of anaerobic reactors were 50%. This study is important for modeling, design, and operation of landfill leachate treatment systems and determination of discharge limits

  16. Re-use of winery wastewaters for biological nutrient removal.

    Science.gov (United States)

    Rodríguez, L; Villaseñor, J; Buendía, I M; Fernández, F J

    2007-01-01

    The aim of this study was to evaluate the feasibility of the re-use of the winery wastewater to enhance the biological nutrient removal (BNR) process. In batch experiments it was observed that the addition of winery wastewater mainly enhanced the nitrogen removal process because of the high denitrification potential (DNP), of about 130 mg N/g COD, of the contained substrates. This value is very similar to that obtained by using pure organic substrates such as acetate. The addition of winery wastewater did not significantly affect either phosphorus or COD removal processes. Based on the experimental results obtained, the optimum dosage to remove each mg of N-NO3 was determined, being a value of 6.7 mg COD/mg N-NO3. Because of the good properties of the winery wastewater to enhance the nitrogen removal, the viability of its continuous addition in an activated sludge pilot-scale plant for BNR was studied. Dosing the winery wastewater to the pilot plant a significant increase in the nitrogen removal was detected, from 58 to 75%. The COD removal was slightly increased, from 89 to 95%, and the phosphorus removal remained constant.

  17. Removal of algal blooms from freshwater by the coagulation-magnetic separation method.

    Science.gov (United States)

    Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck

    2013-01-01

    This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.

  18. Characterization of landfill leachates and studies on heavy metal removal.

    Science.gov (United States)

    Ceçen, F; Gürsoy, G

    2000-10-01

    This study covers a thorough characterisation of landfill leachates emerging from a sanitary landfill area. The landfill leachates were obtained in the acidic stage of landfill stabilisation. Their organic content was high as reflected by the high BOD5 (5 day biological oxygen demand) and COD (chemical oxygen demand) values. They were also highly polluted in terms of the parameters TKN (total Kjeldahl nitrogen), NH4-N, alkalinity, hardness and heavy metals. Nickel was present in these wastewaters at a significant concentration. With regard to the high heavy metal content of these wastewaters, several physicochemical removal alternatives for the heavy metals Cu, Pb, Zn, Ni, Cd, Cr, Mn and Fe were tested using coagulation, flocculation, precipitation, base addition and aeration. Additionally, COD removal and ammonia stripping were examined. Co-precipitation with either alum or iron salts did not usually lead to significantly higher heavy metal removal than lime alone. The major methods leading to an effective heavy metal removal were aeration and lime addition. Nickel and cadmium seemed to be strongly complexed and were not removed by any method. Also lead removal proved to be difficult. The results are also discussed in terms of compliance with standards.

  19. Salt removal using multiple microbial desalination cells under continuous flow conditions

    KAUST Repository

    Qu, Youpeng; Feng, Yujie; Liu, Jia; He, Weihua; Shi, Xinxin; Yang, Qiao; Lv, Jiangwei; Logan, Bruce E.

    2013-01-01

    %, but coulombic efficiencies decreased from 49 ± 4% to 35 ± 1%. Total COD removals were similar at both HRTs (60 ± 2%, 2. days; 59 ± 2%, 1. day). Community analysis of the anode biofilms showed that bacteria most similar to the xylose fermenting bacterium

  20. The Evaluation of Removal Efficiency of COD Due to Water Contaminated by Gasoline by Granular Active Carbon

    Directory of Open Access Journals (Sweden)

    MH Salmani

    2014-11-01

    Conclusion: We can conclude from this study that the activated carbon is an appropriate adsorbent for decreasing of COD due to gasoline contamination in water. The use of this adsorbent can well decrease COD of water contamination due to gasoline at times of 30 min.

  1. Investigation the Efficiency of Combined Coagulation and Advanced Oxidation by Fenton Process in the Removal of Clarithromycin Antibiotic COD

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Yazdanbakhsh

    2012-07-01

    Full Text Available Antibiotics are considered among the major pollutants in water environments. In this study, removal of Claritromycine antibiotic has been studied from synthetic wastewater by combined coagulation and advanced oxidation processes. This study, was done in laboratory scale .  Samples of synthetic wastewater  were prepared from Claritromycin antibiotic. Concentration of samples were 200 mg/l. COD index was selected as a parameter evaluated in this study. In the first stage, coagulation process was done on synthetic wastewater and the proper condition was achieved (proper coagulant, optimum pH, dosage of coagulant. After that, Fenton oxidation process was done, on the effluent of coagulation process. In Fenton process the influence of pH, Fe2+ and hydrogen peroxide were studied on the removal efficiency of Claritromycin antibiotic and the optimum values for each parameter were determined. According to the results of this study, Poly Aluminum Chloride (PAC  is the proper coagulant. With pH equal to 7 and 100 mg/l PAC, 84.37% removal of Claritromycine was achieved.  For fenton process, optimum parameters for the removal of Claritromycin were determined. The optimum condition for fenton process were, pH= 7, Fe2+ equal to 0.45 mmol/ l , hydrogen proxide equal to 0. 16 mmol/l, ratio of H2O2/Fe2+ equal to 0.4 and detention time of 1hour .With Applying of optimum conditions for combined coagulation and Fenton processes, 96.3% removal of Claritromycin was obtained.

  2. Compounds of parasitic roundworm absorbing in the visible region: target molecules for detection of roundworm in Atlantic cod.

    Science.gov (United States)

    Stormo, Svein K; Ernstsen, Arild; Nilsen, Heidi; Heia, Karsten; Sivertsen, Agnar H; Elvevoll, Edel

    2004-07-01

    The objective of this study was to contribute to the development of technology that will be able to replace manual operations in processing of fish fillets. Removal of parasites, black lining, remnants of skin, and bloodstains are costly and time-consuming operations to the fish processing industry. The presence of parasites in fish products tends to spoil consumers' appetites. Recent reports questioning the safety of eating cod infected with parasites might lower consumer acceptance of seafood. Presently, parasites are detected and removed manually. An average efficiency of about 75% under commercial conditions has been reported. In this study, we focused on biochemical differences between cod muscle and the prevalent anisakine nematode species (Anisakis simplex and Pseudoterranova decipiens) infecting Atlantic cod (Gadus morhua). Using reversed phase high-performance liquid chromatography equipped with a photodiode array detector, substances absorbing in the range 300 to 600 nm were identified in extracts from parasite material. These substances were not detected in extracts from cod tissue. Significant biochemical differences between cod muscle and parasite material have thus been demonstrated.

  3. Evaluation of trickle-bed air biofilter performance for MEK removal.

    Science.gov (United States)

    Cai, Zhangli; Kim, Daekeun; Sorial, George A

    2004-10-18

    A lab-scale trickle-bed air biofilter (TBAB) was operated to evaluate the removal of methyl ethyl ketone (MEK) from waste gas. Three biomass control strategies were investigated, namely, backwashing and two non-use periods (starvation and stagnant). Five volumetric loading rates from 0.70 to 7.04 kg COD/m(3)day were employed. Backwashing once a week removed the excess biomass and obtained long-term, stable performance over 99% removal efficiency for loading rates less than 5.63 kg COD/m(3)day. The two non-use periods could also sustain 99% removal efficiency and could be employed as another means of biomass control for loading rates up to 3.52 kg COD/m(3)day. The non-use periods did not delay the recovery when the loading rate did not exceed 3.52 kg COD/m(3)day. The pseudo-first-order removal rate constant decreased with increase in volumetric loading rate. The effect of non-use periods on removal rate showed apparent transition from positive to negative with the increase in loading rate.

  4. Enhanced nitrogen removal in single-chamber microbial fuel cells with increased gas diffusion areas

    KAUST Repository

    Yan, Hengjing

    2012-11-23

    Single-chamber microbial fuel cells (MFCs) with nitrifiers pre-enriched at the air cathodes have previously been demonstrated as a passive strategy for integrating nitrogen removal into current-generating bioelectrochemical systems. To further define system design parameters for this strategy, we investigated in this study the effects of oxygen diffusion area and COD/N ratio in continuous-flow reactors. Doubling the gas diffusion area by adding an additional air cathode or a diffusion cloth significantly increased the ammonia and COD removal rates (by up to 115% and 39%), ammonia removal efficiency (by up to 134%), the cell voltage and cathode potentials, and the power densities (by a factor of approximately 2). When the COD/N ratio was lowered from 13 to 3, we found up to 244% higher ammonia removal rate but at least 19% lower ammonia removal efficiency. An increase of COD removal rate by up to 27% was also found when the COD/N ratio was lowered from 11 to 3. The Coulombic efficiency was not affected by the additional air cathode, but decreased by an average of 11% with the addition of a diffusion cloth. Ammonia removal by assimilation was also estimated to understand the ammonia removal mechanism in these systems. These results showed that the doubling of gas diffusion area enhanced N and COD removal rates without compromising electrochemical performance. © 2012 Wiley Periodicals, Inc.

  5. Biogas Production and Removal COD – BOD and TSS from Wastewater Industrial Alcohol (Vinasse by Modified UASB Bioreactor

    Directory of Open Access Journals (Sweden)

    Utami Isni

    2016-01-01

    Full Text Available Biogas production and decreased organic loading of vinasse using a modified UASB bioreactor has been done successfully. Vinasse is waste from the ethanol industry which contains COD: 9.360 mg / L , BOD : 4.013 mg/L, and TSS: 317.5 mg/L. The purpose of this research was to study the performance of bioreactors Upflow Anaerobic Sludge Blanket (UASB to decompose the vinasse into biogas or methane. UASB operating principle is to distribute wastewater in the bioreactor to flow upward through the sludge blanket by setting the hidrolic retention time (HRT. Four UASB bioreactor columns were used in this experiment wherein each with a capacity of 50 L in volume; 23 cm inside diameter, and 120 cm. The variations of hydraulic capacity followed the variations of HRT in the range of 72-36 hours. Modifications were carried out on the top of column UASB with the aim of preventing gas losses and increasing the flowrate of gas out from the top of the column. The results showed that HRT increased from 36 h to 72 h followed by an increase in COD removal efficiency of 55.64% to 66.81%; BOD5 from 67.85% to 74.58%; and TSS from 66.69% to 84.19%. The maximum volume of biogas produced was in the range of 5.826 L / day (42.89% methane to 7.930 L / day (methane 58.06%.

  6. Anaerobic treatment of agro-industrial wastewaters for COD removal in expanded granular sludge bed bioreactor

    Directory of Open Access Journals (Sweden)

    Abumalé Cruz-Salomón

    2017-12-01

    Full Text Available Untreated agro-industrial wastewaters are undesirable in the aquatic environment due to the presence of high organic matter contents. However, they may constitute a large potential for biogas production. The present investigation is focused on three laboratory-scale anaerobic expanded granular sludge bed (EGSB bioreactors, continuously operated for 60 d under mesophilic condition with the aim of exploring the feasibility of treating three most significant agro-industrial wastewaters in Chiapas, Mexico (i.e., cheese whey, vinasse, and coffee-processing wastewater. The EGSB bioreactors were operated with a hydraulic retention time (HRT of 6 d under stable conditions (i.e., buffer index (BI of 0.31, 0.34, and 0.03, generating a maximum chemical oxygen demand (COD removal efficiency of 91, 74, and 96% with an average methane production of 340, 245, and 300 mL/g COD∙d for cheese whey, vinasse, and coffee-processing wastewater, respectively. According to the obtained results, the EGSB bioreactors could be a sustainable alternative to simultaneously solve the environmental problems and to produce bioenergy.

  7. Effect of Molasses on Phenol Removal Rate Using Pilot-Scale Anaerobic Reactors

    Directory of Open Access Journals (Sweden)

    Abdollah Dargahi

    2014-10-01

    Full Text Available With the growing industrial and social development through time, toxic substances such as phenol and its derivatives are increasingly released into the environment from a variety of sources. The present study aims to investigate the effects of molasses on phenol removal. For this purpose, five pilot scale batch reactors (5 Erlenmeyer flasks equipped with the air and gas diffusion control system were used in the laboratory scale. The volumes of the reactors were kept constant with a final volume content of 550 ml in each reactor. Phenol with a fixed concentration of 100 mg/l was tested under anaerobic conditions in each reactor in contact with beet molasses (organic matter used as the auxiliary substrate with COD concentrations of 10000, 5000, 2000, 1000, and 500 mg/l over 5 retention times (10, 20, 30, 40, and 50 days. All the sampling and testing procedures wer e performed according to the standard methods. The results showed that in all the five experimental reactors, increasing retention time was accompanied by a continuous decline in initial phenol and COD concentrations. However, for each retention time, increasing COD concentration led to a decrease in COD removal efficiency such that increasing the initial COD concentration up to a certain level was associated with an increase in chemical oxygen demanding materials, but beyond this range, COD removal decreased slowly. It was also found that phenol removal increased with increasing retention time but it was not proportional to the concentration of the biodegradable COD. After 50 days of contact with 1000 mg/l of the supporting substrate, phenol removal in the reactors reached 98.62%. Another finding of the study was the fact that the highest phenol removal was achieved when 1000-2000 mg/l of biodegradable COD was used over 50 days of retention time

  8. Association between nematode Hysterothylacium aduncum invasion of cod larvae and growth

    DEFF Research Database (Denmark)

    Mehrdana, Foojan; Bahlool, Qusay Z. M.; Kuhn, Jesper

    Parasitic nematodes of the superfamily Ascaridoidea are distributed worldwide also with numerous representatives in fish. They have an important role to play in the aquatic environment and may affect survivability of fish. The life cycle of many of these fish infecting roundworm species includes...... invertebrates and fish species and for some species also higher vertebrate hosts. We have recently demonstrated that fry of North Sea cod has a high prevalence of infection with regard to the nematode Hysterothylacium aduncum and it was indicated that these infections could affect survival of cod and thereby......, lapillus otoliths were removed, polished and the number of growth zones in each otolith counted by light microscopy. Each growth zone indicates one day of the fish life span. Covariance analysis demonstrated highly significant differences (p≤ 0.001) between the growth rate of infected and uninfected cod...

  9. Removal of chemical oxygen demand from textile wastewater using a natural coagulant

    Energy Technology Data Exchange (ETDEWEB)

    Ramavandi, Bahman [Bushehr University of Medical Sciences, Bushehr (Iran, Islamic Republic of); Farjadfard, Sima [Islamic Azad University, Tehran (Iran, Islamic Republic of)

    2014-01-15

    A biomaterial was successfully synthesized from Plantago ovata by using an FeCl{sub 3}-induced crude extract (FCE). The potential of FCE to act as a natural coagulant was tested for the pretreatment of real textile wastewater. Tests were performed to evaluate the effects of FCE quantity, salt concentration, and wastewater pH on chemical oxygen demand (COD) reduction during a coagulation/flocculation process. Experimental results indicated that the wastewater could be effectively treated by using a coagulation/flocculation process, where the BOD{sub 5}/COD ratio of the effluent was improved to 0.48. A low coagulant dose, 1.5mg/L, achieved a high COD removal percentage, 89%, at operational conditions of neutral pH and room temperature. The experimental data revealed that the maximum COD removal occurred at water pH<8. Increasing the salt promoted the COD removal. The settling and filterability characteristics of the sludge were also studied. Scanning electron microscopy and energy dispersive spectroscopy studies were conducted to determine the sludge structure and composition, respectively. Overall, FCE as an eco-friendly biomaterial was revealed to be a very efficient coagulant and a promising option for the removal of COD from wastewaters.

  10. APPLICATION OF ELECTROCHEMICAL METHODS FOR DECREASING OF CHEMICAL OXYGEN DEMAND (COD AND TOTAL SUSPENDED SOLID (TSS OF TOFU INDUSTRIAL WASTEWATER

    Directory of Open Access Journals (Sweden)

    Suyata

    2015-05-01

    Full Text Available Tofu industrial wastewater has high COD and TSS level, which it cause an environmental pollution. Therefore, it is necessary to decrease the value of COD and TSS of tofu industrial wastewater before discharge into the water body. Decreasing of COD and TSS values can be carried out using an electrochemical method. The purpose of this research was to determine the effect of potential, electrode distance, pH, and time to decrease of COD and TSS value of the tofu industrial wastewater. The experiment has been performed by electrolysis tofu industrial wastewater using PbO2 as anode and Pb as cathode. The result of the research showed that under the optimum conditions of 12 V voltage, 1 cm electrode distance, pH 1, and electrolysis time of 120 minutes, decreasing COD and TSS of 96.33% and 87.87% respectively

  11. Multi-Level Contact Oxidation Process Performance When Treating Automobile Painting Wastewater: Pollutant Removal Efficiency and Microbial Community Structures

    Directory of Open Access Journals (Sweden)

    Yufang Zhu

    2017-11-01

    Full Text Available This study applied a multi-level contact oxidation process system in a pilot-scale experiment to treat automobile painting wastewater. The experimental wastewater had been pre-treated through a series of physicochemical methods, but the water still contained a high concentration of chemical oxygen demand (COD and had poor biodegradability. After the biological treatment, the COD concentration of effluent could stay below 300 mg/L. The study analyzed the effects of hydraulic residence time (HRT on COD, ammonia nitrogen (NH4+-N, and total nitrogen (TN. The optimal HRT was 8 h; at that time, removal efficiencies of COD, ammonia nitrogen, and total nitrogen were 83.8%, 86.3%, and 65%, respectively. The system also greatly reduced excess sludge production; the removal efficiency was 82.8% with a HRT of 8 h. The study applied high-throughput pyrosequencing technology to evaluate the microbial diversity and community structures in distinct stages of the biological reactor. The relevance between process performance and microbial community structure was analyzed at the phylum and class level. The abundant Firmicutes made a large contribution to improving the biodegradability of painting wastewater through hydrolysis acidification and reducing sludge production through fermentation in the biological reactor.

  12. Effects of sludge retention time (SRT) and biosurfactant on the removal of polyaromatic compounds and toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Sponza, Delia Teresa, E-mail: delya.sponza@deu.edu.tr [Dokuz Eylul University, Engineering Faculty, Environmental Engineering Department, Buca Kaynaklar Campus, 35160 Izmir (Turkey); Gok, Oguzhan [Dokuz Eylul University, Engineering Faculty, Environmental Engineering Department, Buca Kaynaklar Campus, 35160 Izmir (Turkey)

    2011-12-15

    Graphical abstract: Acute toxicities in (a) influent wastewater (EC{sub 50} = 45.02 ng ml{sup -1}) and (b) effluent wastewater in aerobic activated sludge reactor at SRT = 25 days (EC{sub 6} = 5.30 ng ml{sup -1}). Highlights: Black-Right-Pointing-Pointer Over 90% of the total PAHs was removed at Rhamnolipid and sludge retention time of 15 mg l{sup -1} and 25 days. Black-Right-Pointing-Pointer 93% of the COD originating from the inert organics was removed in the aerobic reactor. 96-97% of the Rhamnolipid was biodegraded. Black-Right-Pointing-Pointer The EC50 value was reduced from EC{sub 50} = 45.02 ng ml{sup -1} to C{sub 6} = 5.30 ng ml{sup -1} with Daphnia magna. Toxicity removals originating from the PAHs were 96%. - Abstract: A laboratory-scale aerobic activated sludge reactor (AASR) system was employed to investigate the effects of SRT on the removal of three less hydrophobic and six more hydrophobic PAHs in the presence of rhamnolipid (RD), emulsan (EM) and surfactine (SR) biosurfactants. Among the biosurfactants it was found that RD exhibits a better performance than the others in the removal of PAHs. At a RD of 15 mg l{sup -1} aerobic treatment for 25 days SRT was enough to remove over 90% of the total PAHs, 88% of the COD originating from the inert organics (COD{sub inert}) and 93% of the COD originating from the inert soluble microbial products (COD{sub imp}). At this SRT and RD concentration, about 96-98% of the RD was biodegraded by the AASR system, 1.2-1.4% was accumulated in the system, 1.1-1.3% was released in the effluent, and 1.2-1.4% remained in the waste sludge. The addition of electron acceptors (NO{sub 3}{sup -1}, SO{sub 4}{sup -2}) and increasing of temperature up to 45 Degree-Sign C enhanced the PAH yields. The most effective PAH degradation occurred in high-oxygenated and neutral pH conditions. The PAH concentration affecting half of the Daphnia magna organism (EC{sub 50} value) was reduced from EC{sub 50} = 45.02 ng ml{sup -1} to the PAH

  13. Effects of sludge retention time (SRT) and biosurfactant on the removal of polyaromatic compounds and toxicity

    International Nuclear Information System (INIS)

    Sponza, Delia Teresa; Gok, Oguzhan

    2011-01-01

    Graphical abstract: Acute toxicities in (a) influent wastewater (EC 50 = 45.02 ng ml −1 ) and (b) effluent wastewater in aerobic activated sludge reactor at SRT = 25 days (EC 6 = 5.30 ng ml −1 ). Highlights: ► Over 90% of the total PAHs was removed at Rhamnolipid and sludge retention time of 15 mg l −1 and 25 days. ► 93% of the COD originating from the inert organics was removed in the aerobic reactor. 96–97% of the Rhamnolipid was biodegraded. ► The EC50 value was reduced from EC 50 = 45.02 ng ml −1 to C 6 = 5.30 ng ml −1 with Daphnia magna. Toxicity removals originating from the PAHs were 96%. - Abstract: A laboratory-scale aerobic activated sludge reactor (AASR) system was employed to investigate the effects of SRT on the removal of three less hydrophobic and six more hydrophobic PAHs in the presence of rhamnolipid (RD), emulsan (EM) and surfactine (SR) biosurfactants. Among the biosurfactants it was found that RD exhibits a better performance than the others in the removal of PAHs. At a RD of 15 mg l −1 aerobic treatment for 25 days SRT was enough to remove over 90% of the total PAHs, 88% of the COD originating from the inert organics (COD inert ) and 93% of the COD originating from the inert soluble microbial products (COD imp ). At this SRT and RD concentration, about 96–98% of the RD was biodegraded by the AASR system, 1.2–1.4% was accumulated in the system, 1.1–1.3% was released in the effluent, and 1.2–1.4% remained in the waste sludge. The addition of electron acceptors (NO 3 −1 , SO 4 −2 ) and increasing of temperature up to 45 °C enhanced the PAH yields. The most effective PAH degradation occurred in high-oxygenated and neutral pH conditions. The PAH concentration affecting half of the Daphnia magna organism (EC 50 value) was reduced from EC 50 = 45.02 ng ml −1 to the PAH concentration affecting only 6% of the live Daphnia magna (EC 6 = 5.30 ng ml −1 ) at the end of the aerobic treatment at a SRT of 25 days. Toxicity

  14. Removal of organic pollutants from produced water using Fenton oxidation

    Directory of Open Access Journals (Sweden)

    Afzal Talia

    2018-01-01

    Full Text Available Produced water (PW is the largest stream of wastewater from oil and gas exploration. It is highly polluted and requires proper treatment before disposal. The main objective of this study was to investigate the effectiveness of Fenton oxidation in degradation of organic matter in PW. The role of operating factors viz., H2O2 concentration (0.12 × 10-3 moles/L to 3 moles/L, [H2O2]/[Fe2+] molar ratio (2 to 75, and reaction time (30 to 200 minutes, on COD removal was determined through a series of batch experiments conducted in acidic environment at room temperature. The experiments were conducted with 500 mL PW samples in 1L glass beakers covered on the outside with aluminum foil to protect them from sunlight. Pre-decided amounts of ferrous sulfate heptahydrate (FeSO4.7H2O and hydrogen peroxide (H2O2 were added to initiate the Fenton reaction. An increase in COD removal was observed with increase in reaction time and [H2O2]/[Fe2+] molar ratio. COD removal also increased with H2O2 concentration up to 0.01 moles/L; further increase in H2O2 concentration decreased the COD removal efficiency. Over 90% COD removal was achieved under optimum reaction conditions. The study indicates that Fenton oxidation is effective for remediation of PW in terms of organic matter removal.

  15. Removal of organic pollutants from produced water using Fenton oxidation

    Science.gov (United States)

    Afzal, Talia; Hasnain Isa, Mohamed; Mustafa, Muhammad Raza ul

    2018-03-01

    Produced water (PW) is the largest stream of wastewater from oil and gas exploration. It is highly polluted and requires proper treatment before disposal. The main objective of this study was to investigate the effectiveness of Fenton oxidation in degradation of organic matter in PW. The role of operating factors viz., H2O2 concentration (0.12 × 10-3 moles/L to 3 moles/L), [H2O2]/[Fe2+] molar ratio (2 to 75), and reaction time (30 to 200 minutes), on COD removal was determined through a series of batch experiments conducted in acidic environment at room temperature. The experiments were conducted with 500 mL PW samples in 1L glass beakers covered on the outside with aluminum foil to protect them from sunlight. Pre-decided amounts of ferrous sulfate heptahydrate (FeSO4.7H2O) and hydrogen peroxide (H2O2) were added to initiate the Fenton reaction. An increase in COD removal was observed with increase in reaction time and [H2O2]/[Fe2+] molar ratio. COD removal also increased with H2O2 concentration up to 0.01 moles/L; further increase in H2O2 concentration decreased the COD removal efficiency. Over 90% COD removal was achieved under optimum reaction conditions. The study indicates that Fenton oxidation is effective for remediation of PW in terms of organic matter removal.

  16. Presence of helminth eggs in domestic wastewater and its removal at low temperature UASB reactors in Peruvian highlands.

    Science.gov (United States)

    Yaya-Beas, Rosa-Elena; Cadillo-La-Torre, Erika-Alejandra; Kujawa-Roeleveld, Katarzyna; van Lier, Jules B; Zeeman, Grietje

    2016-03-01

    This work studied the anaerobic sludge filtration capacity for pathogens reduction in a 29 L and 1.65 m height lab-scale UASB reactor treating domestic wastewater at low temperatures in the city of Puno (Peru). The anaerobic sludge filtration capacity was performed applying upflow velocities of 0.12, 0.14, 0.16, 0.20, 0.27 and 0.41 m/h. Results show that the HE removal varied between 89 and 95% and the most common specie was Ascaris lumbricoides. Faecal coliform and Escherichia coli removal varied in the range of 0.9-2.1 and 0.8-1.6 log10 respectively. Likely related to the low operational temperatures, the total COD removal varied between 37 and 62%. The best performance in terms of removal of HE, total COD and turbidity was obtained at the lowest upflow velocity of 0.12 m/h. In order to meet WHO standards for water reuse a post-treatment unit will be required to polish the effluent. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Genomics of Arctic cod

    Science.gov (United States)

    Wilson, Robert E.; Sage, George K.; Sonsthagen, Sarah A.; Gravley, Megan C.; Menning, Damian; Talbot, Sandra L.

    2017-01-01

    The Arctic cod (Boreogadus saida) is an abundant marine fish that plays a vital role in the marine food web. To better understand the population genetic structure and the role of natural selection acting on the maternally-inherited mitochondrial genome (mitogenome), a molecule often associated with adaptations to temperature, we analyzed genetic data collected from 11 biparentally-inherited nuclear microsatellite DNA loci and nucleotide sequence data from from the mitochondrial DNA (mtDNA) cytochrome b (cytb) gene and, for a subset of individuals, the entire mitogenome. In addition, due to potential of species misidentification with morphologically similar Polar cod (Arctogadus glacialis), we used ddRAD-Seq data to determine the level of divergence between species and identify species-specific markers. Based on the findings presented here, Arctic cod across the Pacific Arctic (Bering, Chukchi, and Beaufort Seas) comprise a single panmictic population with high genetic diversity compared to other gadids. High genetic diversity was indicated across all 13 protein-coding genes in the mitogenome. In addition, we found moderate levels of genetic diversity in the nuclear microsatellite loci, with highest diversity found in the Chukchi Sea. Our analyses of markers from both marker classes (nuclear microsatellite fragment data and mtDNA cytb sequence data) failed to uncover a signal of microgeographic genetic structure within Arctic cod across the three regions, within the Alaskan Beaufort Sea, or between near-shore or offshore habitats. Further, data from a subset of mitogenomes revealed no genetic differentiation between Bering, Chukchi, and Beaufort seas populations for Arctic cod, Saffron cod (Eleginus gracilis), or Walleye pollock (Gadus chalcogrammus). However, we uncovered significant differences in the distribution of microsatellite alleles between the southern Chukchi and central and eastern Beaufort Sea samples of Arctic cod. Finally, using ddRAD-Seq data, we

  18. Kinetic rates and mass balance of COD, TKN, and TP using SBR treating domestic and industrial wastewater.

    Science.gov (United States)

    Warodomrungsimun, Chaowalit; Fongsatitkul, Prayoon

    2009-12-01

    To assess the performance of SBR to treat three different types of wastewater from domestic, hospital, slaughterhouse and investigate the kinetic rates of active biomass. Mass balance calculation of COD, TKN and TP was further performed to explain the mechanisms of the biological nutrient removals processed in the SBR system. The measured kinetic rates were in turn used to evaluate the process performances under different types of wastewater. Experimental research involving 3 similar SBR lab-scales were installed and operated at the Sanitary Engineering Laboratory. The reactors were seeded with sludge biomass obtained from the Sri-Phraya Domestic Wastewater Treatment Plant in Bangkok. The slaughterhouse, hospital and domestic wastewaters were treated by SBR system for biological organic carbon (COD), nitrogen (TKN) and phosphorus removals. Biological methods for kinetic rates evaluation were conducted in five replicated batch tests. The removal efficiencies of COD and TKN were greater than 90% for all three types of wastewater while the biological phosphorus removal for domestic and hospital wastewaters were less than 60% and phosphorus removal for slaughterhouse exceeded 95%. The kinetic rates of nitrification and denitrification of hospital wastewater was lower than those the domestic and slaughterhouse wastewaters. Phosphorus release and uptake rates of slaughterhouse wastewater were high but domestic and hospital wastewaters were very low. The result of system removal efficiency and batch test for kinetic rates confirmed that the domestic and hospital wastewaters were in deficiency of organic carbon with respect to its ability to support successful biological phosphorus removal.

  19. Investigation and optimization of the novel UASB-MFC integrated system for sulfate removal and bioelectricity generation using the response surface methodology (RSM).

    Science.gov (United States)

    Zhang, Baogang; Zhang, Jing; Yang, Qi; Feng, Chuanping; Zhu, Yuling; Ye, Zhengfang; Ni, Jinren

    2012-11-01

    COD/sulfate ratio and hydraulic residence time (HRT), both of which influence sulfate loadings jointly, are recognized as the most two important affecting factors for sulfate removal and bioelectricity generation in the novel up-flow anaerobic sludge blanket reactor-microbial fuel cell (UASB-MFC) integrated system. The response surface methodology (RSM) was employed for the optimization of this system and the optimum condition with COD/sulfate ratio of 2.3 and HRT of 54.3h was obtained with the target of maximizing the power output. In terms of maximizing the total sulfate removal efficiency, the obtained optimum condition was COD/sulfate ratio of 3.7 and HRT of 55.6h. Experimental results indicated the undistorted simulation and reliable optimized results. These demonstrated that RSM was effective to evaluate and optimize the UASB-MFC system for sulfate removal and energy recovery, providing a promising guide to further improvement of the system for potential applications. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Effect of feed strategy and cod/sulfate ratio on the removal of sulfate in an AnSBBR with recirculation of the liquid phase

    International Nuclear Information System (INIS)

    Archilha, N. C.; Canto, C. S. A.; Ratusznei, S. M.; Rodrigues, J. A.D.; Zaiat, M.; Foresti, E.

    2009-01-01

    The objective of this work was to analyze the effect of the interaction between feed strategy and COD/[SO 4 2 ] ratio on the efficiency of sulfate removal from a synthetic wastewater. To this end, an anaerobic sequencing batch reactor, with recirculation of the liquid phase, containing immobilized biomass on polyurethane foam (AnSBBR) was used. The reactor, with a working volume of 2.7 L, treated 2.0 L synthetic wastewater in 8-h cycles. The system was inoculated with anaerobic biomass from a UASB reactor and was maintained at 30± 1 degree centigrade in a chamber with temperature control. (Author)

  1. Removal of contaminants in a paper mill effluent by Azolla caroliniana

    Directory of Open Access Journals (Sweden)

    D. Sivakumar

    2015-09-01

    Full Text Available This study was focused on removal of various parameters in paper mill effluent using a method called bioremediation by Azolla caroliniana.  The experimental investigations have been carried out using Azolla caroliniana for conducting the sorption study with various dilution ratios (2, 4, 6, 8, and 10, pH (3, 4, 5, 6, 7, 8 and 9 and biomass (200, 400, 600, 800 and 1000 g. The maximum removal percentage of TDS, BOD and COD in a paper mill effluent was obtained at the optimum dilution ratio of 6, pH of 8 and biomass of 800 g. The results of this study indicated that the maximum removal percentage of TDS, BOD and COD in a paper mill effluent was 82.3 %, 88.6 % and 79.1 % respectively.  Also, the study focused on uptake of TDS, BOD and COD in paper mill effluent by Azolla caroliniana through bioaccumulation factor and translocation factor. The results of bioaccumulation factor revealed that TDS, BOD and COD in paper mill effluent were adsorbed by Azolla caroliniana.  The results of translocation factor revealed that the roots of Azolla caroliniana translocate the TDS, BOD and COD in a paper mill effluent to the shoots of Azolla caroliniana. From the results, this study concluded that bioremediation by Azolla caroliniana could be effectively used for removing TDS, BOD and COD in a paper mill effluent. This study also suggested that Azolla caroliniana may be used for removing various contaminants, not only from paper mill effluent, but also from any other industrial effluents.

  2. Colour and organic removal of biologically treated coffee curing wastewater by electrochemical oxidation method.

    Science.gov (United States)

    Bejankiwar, Rajesh S; Lokesh, K S; Gowda, T P Halappa

    2003-05-01

    The treatment of biologically treated wastewater of coffee-curing industry by the electrochemical oxidation using steel anode was investigated. Bench-scale experiments were conducted for activated sludge process on raw wastewater and the treated effluents were further treated by electrochemical oxidation method for its colour and organic content removal. The efficiency of the process was determined in terms of removal percentage of COD, BOD and colour during the course of reaction. Several operating parameters like time, pH and current density were examined to ascertain their effects on the treatment efficiency. Steel anode was found to be effective for the COD and colour removal with anode efficiency of 0.118 kgCOD x h(-1) x A(-1) x m(-2) and energy consumption 20.61 kWh x kg(-1) of COD at pH 9. The decrease in pH from 9 to 3 found to increase the anode efficiency from 0.118 kgCOD x h(-1) x A(-1) x m(-2) to 0.144 kWh x kg(-1) of COD while decrease the energy consumption from 20.61 kWh x kg(-1) of COD to 12.86 kWh x kg(-1) of COD. The pH of 5 was considered an ideal from the present treatment process as it avoids the addition of chemicals for neutralization of treated effluents and also economical with respect to energy consumption. An empirical relation developed for relationship between applied current density and COD removal efficiency showed strong predictive capability with coefficient of determination of 96.5%.

  3. Anammox for ammonia removal from pig manure effluents: Effect of organic matter content on process performance

    DEFF Research Database (Denmark)

    Salces, Beatriz Molinuevo; García, M. C.; Karakashev, Dimitar Borisov

    2009-01-01

    oxidation) diluted with synthetic wastewater. High ammonium removal was achieved, up to 92.1 +/- 4.9% for diluted UASB-post-digested effluent (95 mg COD L-1) and up to 98.5 +/- 0.8% for diluted partially oxidized effluent (121 mg COD L-1). Mass balance clearly showed that an increase in organic loading......The anammox process, under different organic loading rates (COD), was evaluated using a semi-continous UASB reactor at 37 degrees C. Three different substrates were used: initially, synthetic wastewater, and later, two different pig manure effluents (after UASB-post-digestion and after partial...... improved ammonium removal at high organic matter concentration. Up to threshold organic load concentration of 142 mg COD L-1 of UASB-post-digested effluent and 242 mg COD L-1 of partially oxidized effluent, no effect of organic loading on ammonia removal was registered (ammonium removal was above 80...

  4. Submerged anaerobic membrane bioreactor (SAnMBR) performance on sewage treatment: removal efficiencies, biogas production and membrane fouling.

    Science.gov (United States)

    Chen, Rong; Nie, Yulun; Ji, Jiayuan; Utashiro, Tetsuya; Li, Qian; Komori, Daisuke; Li, Yu-You

    2017-09-01

    A submerged anaerobic membrane reactor (SAnMBR) was employed for comprehensive evaluation of sewage treatment at 25 °C and its performance in removal efficiency, biogas production and membrane fouling. Average 89% methanogenic degradation efficiency as well as 90%, 94% and 96% removal of total chemical oxygen demand (TCOD), biochemical oxygen demand (BOD) and nonionic surfactant were obtained, while nitrogen and phosphorus were only subjected to small removals. Results suggest that SAnMBRs can effectively decouple organic degradation and nutrients disposal, and reserve all the nitrogen and phosphorus in the effluent for further possible recovery. Small biomass yields of 0.11 g mixed liquor volatile suspended solids (MLVSS)/gCOD were achieved, coupled to excellent methane production efficiencies of 0.338 NLCH 4 /gCOD, making SAnMBR an attractive technology characterized by low excess sludge production and high bioenergy recovery. Batch tests revealed the SAnMBR appeared to have the potential to bear a high food-to-microorganism ratio (F/M) of 1.54 gCOD/gMLVSS without any inhibition effect, and maximum methane production rate occurred at F/M 0.7 gCOD/gMLVSS. Pore blocking dominated the membrane fouling behaviour at a relative long hydraulic retention time (HRT), i.e. >12 hours, while cake layer dominated significantly at shorter HRTs, i.e. <8 hours.

  5. PENGGUNAAN BIOCATALYS ELECTROLYSIS DALAM PENURUNAN KONSENTRASI TOTAL SUSPENDED SOLID (TSS DAN CHEMICAL OXYGEN DEMAND (COD LIMBAH DOMESTIK

    Directory of Open Access Journals (Sweden)

    Wiharyanto Oktiawan

    2016-09-01

    Full Text Available Secara umum air limbah kegiatan rumah tangga (domestik dibuang langsung menuju badan air seperti sungai dan danau. Pengolahan limbah cair secara biologis (aerob sering menghasilkan lumpur dalam jumlah besar. Jumlah lumpur dapat dikurangi dengan pengolahan anaerob. Sistem bioelektrokimia merupakan salah satu terobosan teknologi yang memungkinkan untuk mengolah limbah sekaligus menghasilkan energi berupa gas metana. Penggunaan biocatalys electrolysis dapat mengatasi kelemahan proses anaerob secara konvensional dalam penurunan konsentrasi TSS dan COD limbah domestik salah satunya mampu menghasilkan gas H2 dari proses elektrolisis. Penambahan daya ekternal sebesar 6 volt mampu menyisihkan TSS sampai kadar 82 mg/l dari kadar semula 157 mg/l. Tegangan 12 volt mampu menurunkan kadar COD sampai 47,46 mg/l dari kadar awal 223 mg/l. Penyisihan TSS paling rendah pada waktu elektrolisis 15 menit dengan kadar 87 mg/l. Penambahan waktu elektrolisis sebanding dengan penurunan konsentrasi COD limbah domestik. Pada penelitian ini kualitas maupun kuantitas gas metana tidak diketahui secara jelas. Selain gas metan, produk fermentasi juga belum diketahui.

  6. Prediction of COD and NH4+-N Concentrations in Leachate from Lab-scale Landfill Bioreactors Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohamad Javad Zoqi

    2010-06-01

    Full Text Available In this study, we present an Artificial Neural Network (ANN model for predicting COD and NH4+-N concentrations in landfill leachate from lab-scale landfill bioreactors. For this purpose, two different lab-scale systems were modeled. for neural network’s data obtained. In the first system, the leachate from a fresh-waste reactor was drained to a recirculation tank and recycled every two days. In the second, the leachate from a fresh waste landfill reactor was fed through a well-decomposed refuse landfill reactor, while the leachate from a well-decomposed refuse landfill reactor was simultaneously recycled to a fresh waste landfill reactor. The results indicate that leachate NH4+-N and COD concentrations accumulated to a high level in the first system, while. NH4+-N and COD removals were successfully carried out in the second. Also, average removal efficiencies in the second system reached 85% and 34% for COD and NH4+-N, respectively. Finally, the ANN’s results exhibited the success of the model as witnessed by the excellent agreement obtained between measured and predicted values.

  7. Simultaneous removal of carbon and nitrogen by mycelial pellets of a heterotrophic nitrifying fungus-Penicillium sp. L1.

    Science.gov (United States)

    Liu, Yuxiang; Hu, Tingting; Zhao, Jing; Lv, Yongkang; Ren, Ruipeng

    2017-02-01

    A novel heterotrophic nitrifying fungus, defined as Penicillium sp. L1, can form mycelial pellets in liquid medium in this study. The effects of inoculation method, C/N ratio, initial pH, and temperature were gradually evaluated to improve the simultaneous removal of total nitrogen (TN) and chemical oxygen demand (COD) in wastewater by Penicillium sp. L1. Results showed that compared with spore inoculation, 48 h pellet inoculum could significantly increase the pellet size (from about 1.5 mm to 3.2 mm) and improve the removal capability, particularly for COD removal (from less than 50-86.20%). The removal efficiencies of TN and COD reached 98.38% (from 136.01 mg/L to 2.20 mg/L) and 92.40% (from 10,720 mg/L to 815 mg/L) under the following conditions: C/N 36, pH 3, 30°C, and inoculation with 48 h pellets. The pellet diameter reached 4.8 mm after 4-day cultivation. In this case, Penicillium sp. L1 removed TN from 415.93 mg/L to 43.39 mg/L, as well as COD from 29,533 mg/L to 8850 mg/L. Overall, the results indicated that the pellet size was closely related to the pollutant-removal ability of Penicillium sp. L1. Furthermore, mycelial pellets (4.8 mm, dead) only adsorbed 38.08% TN (from 125.45 mg/L to 77.78 mg/L), which indicated that adsorption did not play a major role in the nitrogen-removal process. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  8. Total nitrogen and total phosphorus removal from brackish aquaculture wastewater using effective microorganism

    Science.gov (United States)

    Mohamad, K. A.; Mohd, S. Y.; Sarah, R. S.; Mohd, H. Z.; Rasyidah, A.

    2017-09-01

    Aquaculture is one of dominant food based industry in the world with 8.3% annual growth rate and its development had led to adverse effect on the environment. High nutrient production in form of nitrogenous compound and phosphorus contributed to environmental deterioration such as eutrophication and toxicity to the industry. Usage of Effective Microorganism (EM), one of the biological approaches to remove Total Nitrogen (TN) and Total Phosphorus (TP) in aquaculture pond was proposed. Samples were obtained from the Sea Bass intensive brackish aquaculture wastewater (AW) from fish farm at Juru, Penang and the parameters used to measure the removal of nitrogenous compounds include, pH, EM dosage, shaking, contact time and optimum variable conditions. From the study, for effective contact time, day 6 is the optimum contact time for both TN and TP with 99.74% and 62.78% removal respectively while in terms of optimum pH, the highest TN removal was at pH 7 with 66.89 %. The optimum dosage of EM is 1.5 ml with ratio 1:166 for 81.5 % TN removal was also found appropriate during the experiment. At varied optimum conditions of EM, the removal efficiency of TN and TP were 81.53% and 38.94% respectively while the removal mechanism of TN was highly dependent on the decomposition rate of specific bacteria such as Nitrobacter bacteria, Yeast and Bacillus Subtilis sp. The study has established the efficacy of EM's ability to treat excessive nutrient of TN and TP from AW.

  9. Evaluation of feed COD/sulfate ratio as a control criterion for the biological hydrogen sulfide production and lead precipitation

    International Nuclear Information System (INIS)

    Velasco, Antonio; Ramirez, Martha; Volke-Sepulveda, Tania; Gonzalez-Sanchez, Armando; Revah, Sergio

    2008-01-01

    The ability of sulfate-reducing bacteria to produce hydrogen sulfide and the high affinity of sulfide to react with divalent metallic cations represent an excellent option to remove heavy metals from wastewater. Different parameters have been proposed to control the hydrogen sulfide production by anaerobic bacteria, such as the organic and sulfate loading rates and the feed COD/SO 4 2- ratio. This work relates the feed COD/SO 4 2- ratio with the hydrogen sulfide production and dissolved lead precipitation, using ethanol as carbon and energy source in an up-flow anaerobic sludge blanket reactor. A maximum dissolved sulfide concentration of 470 ± 7 mg S/L was obtained at a feed COD/SO 4 2- ratio of 2.5, with sulfate and ethanol conversions of approximately 94 and 87%, respectively. The lowest dissolved sulfide concentration (145 ± 10 mg S/L) was observed with a feed COD/SO 4 2- ratio of 0.67. Substantial amounts of acetate (510-1730 mg/L) were produced and accumulated in the bioreactor from ethanol oxidation. Although only incomplete oxidation of ethanol to acetate was observed, the consortium was able to remove 99% of the dissolved lead (200 mg/L) with a feed COD/SO 4 2- ratio of 1.5. It was found that the feed COD/SO 4 2- ratio could be an adequate parameter to control the hydrogen sulfide production and the consequent precipitation of dissolved lead

  10. Removal of High -Concentration and Refractory Organic Matter from Diosgenin Manufacture Wastewater : a case study of a demonstration project in Hubei Province, P R China

    Science.gov (United States)

    Bao, J.; Wang, L.

    2009-12-01

    , the volume loading and the removal efficiency of COD reached 3.42 kg COD/(m3.d) and 75% respectively. Bio-contact oxidation process dealt with the effluent from the Improved UASB at room temperature. The HRT was 54 hrs and dissolved oxygen was controlled between 2 to 4 mg/L. Currently, the COD volume loading reached 1.05 kg COD/(m3.d) and the removal efficiency of COD was over 90%. The total removal efficiencies of COD and color were over 99% and 98% respectively in the overall process. The pH, color and COD content of the final effluent were 7, about 200 mg/L and 50 times of the chroma respectively. All these indexes met the criteria of “The National Discharge Standard of Industry Water Pollutants for Sapogenin”(GB 20425-2006). This work was supported by National Key Technologies R&D Program No. 2006BAB04A14-2), the Hubei Provincial Science and Technology Department (No. 2006AA305A05) and Wuhan Science and Technology Bureau (20066002101).

  11. Simultaneous nitrification-denitrification and phosphorus removal in a fixed bed sequencing batch reactor (FBSBR)

    International Nuclear Information System (INIS)

    Rahimi, Yousef; Torabian, Ali; Mehrdadi, Naser; Shahmoradi, Behzad

    2011-01-01

    Research highlights: → Sludge production in FSBR reactor is 20-30% less than SBR reactor. → FSBR reactor showed more nutrient removal rate than SBR reactor. → FSBR reactor showed less VSS/TSS ratio than SBR reactor. - Abstract: Biological nutrient removal (BNR) was investigated in a fixed bed sequencing batch reactor (FBSBR) in which instead of activated sludge polypropylene carriers were used. The FBSBR performance on carbon and nitrogen removal at different loading rates was significant. COD, TN, and phosphorus removal efficiencies were at range of 90-96%, 60-88%, and 76-90% respectively while these values at SBR reactor were 85-95%, 38-60%, and 20-79% respectively. These results show that the simultaneous nitrification-denitrification (SND) is significantly higher than conventional SBR reactor. The higher total phosphorus (TP) removal in FBSBR correlates with oxygen gradient in biofilm layer. The influence of fixed media on biomass production yield was assessed by monitoring the MLSS concentrations versus COD removal for both reactors and results revealed that the sludge production yield (Y obs ) is significantly less in FBSBR reactors compared with SBR reactor. The FBSBR was more efficient in SND and phosphorus removal. Moreover, it produced less excess sludge but higher in nutrient content and stabilization ratio (less VSS/TSS ratio).

  12. Simultaneous nitrification-denitrification and phosphorus removal in a fixed bed sequencing batch reactor (FBSBR)

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Yousef, E-mail: you.rahimi@gmail.com [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave, Tehran (Iran, Islamic Republic of); Torabian, Ali, E-mail: atorabi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave, Tehran (Iran, Islamic Republic of); Mehrdadi, Naser, E-mail: mehrdadi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave, Tehran (Iran, Islamic Republic of); Shahmoradi, Behzad, E-mail: bshahmorady@gmail.com [Department of Environmental Science, University of Mysore, MGM-06 Mysore (India)

    2011-01-30

    Research highlights: {yields} Sludge production in FSBR reactor is 20-30% less than SBR reactor. {yields} FSBR reactor showed more nutrient removal rate than SBR reactor. {yields} FSBR reactor showed less VSS/TSS ratio than SBR reactor. - Abstract: Biological nutrient removal (BNR) was investigated in a fixed bed sequencing batch reactor (FBSBR) in which instead of activated sludge polypropylene carriers were used. The FBSBR performance on carbon and nitrogen removal at different loading rates was significant. COD, TN, and phosphorus removal efficiencies were at range of 90-96%, 60-88%, and 76-90% respectively while these values at SBR reactor were 85-95%, 38-60%, and 20-79% respectively. These results show that the simultaneous nitrification-denitrification (SND) is significantly higher than conventional SBR reactor. The higher total phosphorus (TP) removal in FBSBR correlates with oxygen gradient in biofilm layer. The influence of fixed media on biomass production yield was assessed by monitoring the MLSS concentrations versus COD removal for both reactors and results revealed that the sludge production yield (Y{sub obs}) is significantly less in FBSBR reactors compared with SBR reactor. The FBSBR was more efficient in SND and phosphorus removal. Moreover, it produced less excess sludge but higher in nutrient content and stabilization ratio (less VSS/TSS ratio).

  13. Effect of feed strategy and cod/sulfate ratio on the removal of sulfate in an AnSBBR with recirculation of the liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Archilha, N. C.; Canto, C. S. A.; Ratusznei, S. M.; Rodrigues, J. A.D.; Zaiat, M.; Foresti, E.

    2009-07-01

    The objective of this work was to analyze the effect of the interaction between feed strategy and COD/[SO{sub 4}{sup 2}] ratio on the efficiency of sulfate removal from a synthetic wastewater. To this end, an anaerobic sequencing batch reactor, with recirculation of the liquid phase, containing immobilized biomass on polyurethane foam (AnSBBR) was used. The reactor, with a working volume of 2.7 L, treated 2.0 L synthetic wastewater in 8-h cycles. The system was inoculated with anaerobic biomass from a UASB reactor and was maintained at 30{+-} 1 degree centigrade in a chamber with temperature control. (Author)

  14. Achieving mainstream nitrogen removal through simultaneous partial nitrification, anammox and denitrification process in an integrated fixed film activated sludge reactor.

    Science.gov (United States)

    Wang, Chao; Liu, Sitong; Xu, Xiaochen; Zhang, Chaolei; Wang, Dong; Yang, Fenglin

    2018-07-01

    The anaerobic ammonium oxidation (anammox) is becoming a critical technology for energy neutral in mainstream wastewater treatment. However, the presence of chemical oxygen demanding in influent would result in a poor nitrogen removal efficiency during the deammonification process. In this study, the simultaneous partial nitrification, anammox and denitrification process (SNAD) for mainstream nitrogen removal was investigated in an integrated fixed film activated sludge (IFAS) reactor. SNAD-IFAS process achieved a total nitrogen (TN) removal efficiency of 72 ± 2% and an average COD removal efficiency was 88%. The optimum COD/N ratio for mainstream wastewater treatment was 1.2 ± 0.2. Illumina sequencing analysis and activity tests showed that anammox and denitrifying bacteria were the dominant nitrogen removal microorganism in the biofilm and the high COD/N ratios (≥2.0) leaded to the proliferation of heterotrophic bacteria (Hydrogenophaga) and nitrite-oxidizing bacteria (Nitrospira) in the suspended sludge. Network analysis confirmed that anammox bacteria (Candidatus Kuenenia) could survive in organic matter environment due to that anammox bacteria displayed significant co-occurrence through positive correlations with some heterotrophic bacteria (Limnobacter) which could protect anammox bacteria from hostile environments. Overall, the results of this study provided more comprehensive information regarding the community composition and assemblies in SNAD-IFAS process for mainstream nitrogen removal. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Improvement of NOM Removal from Water Resources by Modifying the Coagulation Process

    Directory of Open Access Journals (Sweden)

    F Vaezi, A Mohagheghian, J Nouri, MR Eshraghian, A Ghasri

    2005-01-01

    Full Text Available As a result of the regulations on DBPs, interest in NOM removal is increasing and many water treatment plants in developed countries have started to measure the concentration of TOC in their finished waters. Promulgation of the rules will substantially increase these efforts in other countries too. Since the cost of TOC (and DBPs determination was high, it was decided to study the traditional analysis of COD as a surrogate measure to detect the organic constituents in raw water and the extent to which optimized coagulation with ferric chloride can increase COD removal. The two water samples studied belonged to Karaj and Jajrood Rivers. For both samples the observed values of COD removal by coagulation at lower pH (about 1-1.5 pH values less than the regular pH were about 85-95 percent without making water turbidity unacceptable. In order to determine the effects of organic content on coagulation, synthetic samples were also prepared with much higher COD values. Again, considerable increases in COD removal have been observed for most of these samples only by decreasing 0.5-2 pH value. The results indicated that a modified coagulation process without need to much increasing the amount of coagulant can be developed for these water samples.

  16. Sono assisted electrocoagulation process for the removal of pollutant from pulp and paper industry effluent.

    Science.gov (United States)

    Asaithambi, P; Aziz, Abdul Raman Abdul; Sajjadi, Baharak; Daud, Wan Mohd Ashri Bin Wan

    2017-02-01

    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm 2 ), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm 2 , electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.

  17. Simultaneous nitrogen and organics removal using membrane aeration and effluent ultrafiltration in an anaerobic fluidized membrane bioreactor

    KAUST Repository

    Ye, Yaoli; Saikaly, Pascal; Logan, B.E.

    2017-01-01

    Dissolved methane and a lack of nutrient removal are two concerns for treatment of wastewater using anaerobic fluidized bed membrane bioreactors (AFMBRs). Membrane aerators were integrated into an AFMBR to form an Aeration membrane fluidized bed membrane bioreactor (AeMFMBR) capable of simultaneous removal of organic matter and ammonia without production of dissolved methane. Good effluent quality was obtained with no detectable suspended solids, 93±5% of chemical oxygen demand (COD) removal to 14±11 mg/L, and 74±8% of total ammonia (TA) removal to 12±3 mg-N/L for domestic wastewater (COD of 193±23 mg/L and TA of 49±5 mg-N/L) treatment. Nitrate and nitrite concentrations were always low (< 1 mg-N/L) during continuous flow treatment. Membrane fouling was well controlled by fluidization of the granular activated carbon (GAC) particles (transmembrane pressures maintained <3 kPa). Analysis of the microbial communities suggested that nitrogen removal was due to nitrification and denitrification based on the presence of microorganisms associated with these processes.

  18. Simultaneous nitrogen and organics removal using membrane aeration and effluent ultrafiltration in an anaerobic fluidized membrane bioreactor

    KAUST Repository

    Ye, Yaoli

    2017-08-03

    Dissolved methane and a lack of nutrient removal are two concerns for treatment of wastewater using anaerobic fluidized bed membrane bioreactors (AFMBRs). Membrane aerators were integrated into an AFMBR to form an Aeration membrane fluidized bed membrane bioreactor (AeMFMBR) capable of simultaneous removal of organic matter and ammonia without production of dissolved methane. Good effluent quality was obtained with no detectable suspended solids, 93±5% of chemical oxygen demand (COD) removal to 14±11 mg/L, and 74±8% of total ammonia (TA) removal to 12±3 mg-N/L for domestic wastewater (COD of 193±23 mg/L and TA of 49±5 mg-N/L) treatment. Nitrate and nitrite concentrations were always low (< 1 mg-N/L) during continuous flow treatment. Membrane fouling was well controlled by fluidization of the granular activated carbon (GAC) particles (transmembrane pressures maintained <3 kPa). Analysis of the microbial communities suggested that nitrogen removal was due to nitrification and denitrification based on the presence of microorganisms associated with these processes.

  19. Enhanced nitrogen removal in single-chamber microbial fuel cells with increased gas diffusion areas

    KAUST Repository

    Yan, Hengjing; Regan, John M.

    2012-01-01

    significantly increased the ammonia and COD removal rates (by up to 115% and 39%), ammonia removal efficiency (by up to 134%), the cell voltage and cathode potentials, and the power densities (by a factor of approximately 2). When the COD/N ratio was lowered

  20. Comparative study on the removal of COD from POME by electrocoagulation and electro-Fenton methods: Process optimization

    Science.gov (United States)

    Chairunnisak, A.; Arifin, B.; Sofyan, H.; Lubis, M. R.; Darmadi

    2018-03-01

    This research focuses on the Chemical Oxygen Demand (COD) treatment in palm oil mill effluent by electrocoagulation and electro-Fenton methods to solve it. Initially, the aqueous solution precipitates in acid condition at pH of about two. This study focuses on the palm oil mill effluent degradation by Fe electrodes in a simple batch reactor. This work is conducted by using different parameters such as voltage, electrolyte concentration of NaCl, volume of H2O2 and operation time. The processing of data resulted is by using response surface method coupled with Box-Behnken design. The electrocoagulation method results in the optimum COD reduction of 94.53% from operating time of 39.28 minutes, 20 volts, and without electrolyte concentration. For electro-Fenton process, experiment points out that voltage 15.78 volts, electrolyte concentration 0.06 M and H2O2 volume 14.79 ml with time 35.92 minutes yield 99.56% degradation. The result concluded that the electro-Fenton process was more effective to degrade COD of the palm-oil-mill effluent compared to electrocoagulation process.

  1. Removal of oxytetracycline (OTC) in a synthetic pharmaceutical wastewater by a sequential anaerobic multichamber bed reactor (AMCBR)/completely stirred tank reactor (CSTR) system: biodegradation and inhibition kinetics.

    Science.gov (United States)

    Sponza, Delia Teresa; Çelebi, Hakan

    2012-01-01

    An anaerobic multichamber bed reactor (AMCBR) was effective in removing both molasses-chemical oxygen demand (COD), and the antibiotic oxytetracycline (OTC). The maximum COD and OTC removals were 99% in sequential AMCBR/completely stirred tank reactor (CSTR) at an OTC concentration of 300 mg L(-1). 51%, 29% and 9% of the total volatile fatty acid (TVFA) was composed of acetic, propionic acid and butyric acids, respectively. The OTC loading rates at between 22.22 and 133.33 g OTC m(-3) d(-1) improved the hydrolysis of molasses-COD (k), the maximum specific utilization of molasses-COD (k(mh)) and the maximum specific utilization rate of TVFA (k(TVFA)). The direct effect of high OTC loadings (155.56 and -177.78 g OTC m(-3) d(-1)) on acidogens and methanogens were evaluated with Haldane inhibition kinetic. A significant decrease of the Haldane inhibition constant was indicative of increases in toxicity at increasing loading rates. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. The stimulating effects of the addition of glucose on denitrification and removal of recalcitrant organic compounds

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2014-03-01

    Full Text Available A laboratory scale aerobic oxidation ditch combined with an anoxic reactor was conducted to treat wastewater from a chemical industrial park in Tianjin, China. The wastewater exhibited a low biodegradability, and the results of gas chromatography mass spectrometry (GC-MS analysis showed that some recalcitrant organic components are present in the wastewater. Ammonia nitrogen (NH4+-N removal efficiency of over 90% was obtained. However, the removal efficiencies of total nitrogen (TN and chemical oxygen demand (COD were below 16% and 15%, respectively. The addition of glucose to the anoxic reactor in the system increased the removal efficiencies of TN and COD to approximately 72% and 25.57%, respectively. Results of mass balance indicate that about 60% of the external carbon was consumed as electron donor for denitrification, while 40% was consumed as a substrate for co-metabolism. The optimal dose of added glucose was also investigated, which was determined at 0.35 to 1.20 (CODglucose:CODoriginal.

  3. Evaluation of feed COD/sulfate ratio as a control criterion for the biological hydrogen sulfide production and lead precipitation

    Energy Technology Data Exchange (ETDEWEB)

    Velasco, Antonio [Direccion General del Centro Nacional de Investigacion y Capacitacion Ambiental-Instituto Nacional de Ecologia, Av. San Rafael Atlixco 186, Col. Vicentina. Iztapalapa, Mexico 09340, D.F. (Mexico)], E-mail: jvelasco@ine.gob.mx; Ramirez, Martha [Direccion General del Centro Nacional de Investigacion y Capacitacion Ambiental-Instituto Nacional de Ecologia, Av. San Rafael Atlixco 186, Col. Vicentina. Iztapalapa, Mexico 09340, D.F. (Mexico); Volke-Sepulveda, Tania [Departamento de Biotecnologia, UAM-Cuajimalpa, San Rafael Atlixco 186, Col. Vicentina. Iztapalapa, Mexico 09340, D.F. (Mexico); Gonzalez-Sanchez, Armando [Departamento de Ingenieria de Procesos, Universidad Autonoma Metropolitana-Iztapalapa, UAM-Cuajimalpa, San Rafael Atlixco 186, Col. Vicentina. Iztapalapa, Mexico 09340, D.F. (Mexico); Revah, Sergio [Departamento de Procesos y Tecnologia, UAM-Cuajimalpa, San Rafael Atlixco 186, Col. Vicentina. Iztapalapa, Mexico 09340, D.F. (Mexico)

    2008-03-01

    The ability of sulfate-reducing bacteria to produce hydrogen sulfide and the high affinity of sulfide to react with divalent metallic cations represent an excellent option to remove heavy metals from wastewater. Different parameters have been proposed to control the hydrogen sulfide production by anaerobic bacteria, such as the organic and sulfate loading rates and the feed COD/SO{sub 4}{sup 2-} ratio. This work relates the feed COD/SO{sub 4}{sup 2-} ratio with the hydrogen sulfide production and dissolved lead precipitation, using ethanol as carbon and energy source in an up-flow anaerobic sludge blanket reactor. A maximum dissolved sulfide concentration of 470 {+-} 7 mg S/L was obtained at a feed COD/SO{sub 4}{sup 2-} ratio of 2.5, with sulfate and ethanol conversions of approximately 94 and 87%, respectively. The lowest dissolved sulfide concentration (145 {+-} 10 mg S/L) was observed with a feed COD/SO{sub 4}{sup 2-} ratio of 0.67. Substantial amounts of acetate (510-1730 mg/L) were produced and accumulated in the bioreactor from ethanol oxidation. Although only incomplete oxidation of ethanol to acetate was observed, the consortium was able to remove 99% of the dissolved lead (200 mg/L) with a feed COD/SO{sub 4}{sup 2-} ratio of 1.5. It was found that the feed COD/SO{sub 4}{sup 2-} ratio could be an adequate parameter to control the hydrogen sulfide production and the consequent precipitation of dissolved lead.

  4. Chemical oxygen demand removal efficiency and limited factors study of aminosilicone polymers in a water emulsion by iron-carbon micro-electrolysis.

    Science.gov (United States)

    Yang, Shangyuan; Liang, Zhiwei; Yu, Huadong; Wang, Yunlong; Chen, Yingxu

    2014-02-01

    Micro-electrolysis was applied in the present study to investigate the effect of pH, iron-carbon mass ratio, contact time, and treatment batch on the removal efficiency of chemical oxygen demand (COD) within an aminosilicone emulsion. The results exhibited that the removal efficiency of COD decreased linearly with the batch increase, and this tendency was consistent under the various conditions. The adsorption of activated carbons contributes a large portion to the elimination of COD within the aminosilicone emulsion. The oxidation action of iron-carbon micro-electrolysis was proven and the aminosilicone emulsion's COD removal contribution was approximately 16%. Aminosilicone polymers were adsorbed on the surface of activated carbons and iron chips, which contributes to the decline of COD removal efficiency and limits the contribution of oxidation action.

  5. Effect of influent aeration on removal of organic matter from coffee processing wastewater in constructed wetlands.

    Science.gov (United States)

    Rossmann, Maike; Matos, Antonio Teixeira; Abreu, Edgar Carneiro; Silva, Fabyano Fonseca; Borges, Alisson Carraro

    2013-10-15

    The aim of the present study was to evaluate the influence of aeration and vegetation on the removal of organic matter in coffee processing wastewater (CPW) treated in 4 constructed wetlands (CWs), characterized as follows: (i) ryegrass (Lolium multiflorum) cultivated system operating with an aerated influent; (ii) non-cultivated system operating with an aerated influent, (iii) ryegrass cultivated system operating with a non-aerated influent; and (iv) non-cultivated system operating with a non-aerated influent. The lowest average chemical oxygen demand (COD), biochemical oxygen demand (BOD) and total suspended solids (TSS) removal efficiencies of 87, 84 and 73%, respectively, were obtained in the ryegrass cultivated system operating with a non-aerated influent. However, ryegrass cultivation did not influence the removal efficiency of organic matter. Artificial aeration of the CPW, prior to its injection in the CW, did not improve the removal efficiencies of organic matter. On other hand it did contribute to increase the instantaneous rate at which the maximum COD removal efficiency was reached. Although aeration did not result in greater organic matter removal efficiencies, it is important to consider the benefits of aeration on the removal of the other compounds. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Satellite monitoring temperature conditions spawning area of the Northeast Arctic cod in the Norwegian Sea and assessment its abundance

    Science.gov (United States)

    Vanyushin, George; Bulatova, Tatiana; Klochkov, Dmitriy; Troshkov, Anatoliy; Kruzhalov, Michail

    2013-04-01

    In this study, the attempt to consider the relationship between sea surface anomalies of temperature (SST anomalies °C) in spawning area of the Norwegian Arctic cod off the Lofoten islands in coastal zone of the Norwegian Sea and modern cod total stock biomass including forecasting assessment of future cod generation success. Continuous long-term database of the sea surface temperature (SST) was created on the NOAA satellites data. Mean monthly SST and SST anomalies are computed for the selected area on the basis of the weekly SST maps for the period of 1998-2012. These maps were plotted with the satellite SST data, as well as information of vessels, byoies and coastal stations. All data were classified by spawning seasons (March-April) and years. The results indicate that poor and low middle generations of cod (2001, 2006, 2007) occurred in years with negative or extremely high positive anomalies in the spawning area. The SST anomalies in years which were close to normal or some more normal significances provide conditions for appearance strong or very strong generations of cod (1998, 2000, 2002, 2004, 2005, 2006, 2008, 2009). Temperature conditions in concrete years influence on different indexes of cod directly. So, the mean temperature in spawning seasons in years 1999-2005 was ≈5,0°C and SST anomaly - +0,35°C, by the way average year significances indexes of cod were: total stock biomass - 1425,0 th.t., total spawning biomass - 460,0 th.t., recruitment (age 3+) - 535,0 mln. units and landings - 530,0 th.t. In spawning seasons 2006-2012 years the average data were following: mean SST ≈6,0°C, SST anomaly - +1,29°C, total stock biomass - 2185,0 th.t., total spawning biomass - 1211,0 th.t., recruitment (age 3+) - 821,0 mln. units and landings - 600,0 th.t. The SST and SST anomalies (the NOAA satellite data) characterize increase of decrease in input of warm Atlantic waters which form numerous eddies along the flows of the main warm currents thus creating

  7. Post-treatment of anaerobically degraded azo dye Acid Red 18 using aerobic moving bed biofilm process: Enhanced removal of aromatic amines

    International Nuclear Information System (INIS)

    Hosseini Koupaie, E.; Alavi Moghaddam, M.R.; Hashemi, S.H.

    2011-01-01

    Highlights: → Biofilm process was applied as post-treatment of anaerobically degraded an azo dye. → More than 65% of the dye total metabolites was completely mineralized. → Based on HPLC analysis, more than 80% of 1-naphthylamine-4-sulfonate was removed. → Inhibition of biofilm growth was increased with increasing the initial dye concentration. → Considerable porous morphology was observed in the SEM photographs of the biofilm. - Abstract: The application of aerobic moving bed biofilm process as post-treatment of anaerobically degraded azo dye Acid Red 18 was investigated in this study. The main objective of this work was to enhance removal of anaerobically formed the dye aromatic metabolites. Three separate sequential treatment systems were operated with different initial dye concentrations of 100, 500 and 1000 mg/L. Each treatment system consisted of an anaerobic sequencing batch reactor (An-SBR) followed by an aerobic moving bed sequencing batch biofilm reactor (MB-SBBR). Up to 98% of the dye decolorization and more than 80% of the COD removal occurred anaerobically. The obtained results suggested no significant difference in COD removal as well as the dye decolorization efficiency using three An-SBRs receiving different initial dye concentrations. Monitoring the dye metabolites through HPLC suggested that more than 80% of anaerobically formed 1-naphthylamine-4-sulfonate was completely removed in the aerobic biofilm reactors. Based on COD analysis results, at least 65-72% of the dye total metabolites were mineralized during the applied treatment systems. According to the measured biofilm mass and also based on respiration-inhibition test results, increasing the initial dye concentration inhibited the growth and final mass of the attached-growth biofilm in MB-SBBRs.

  8. Cod monitoring; results 2015, quarter 3

    NARCIS (Netherlands)

    Reijden, van der K.J.; Machiels, M.A.M.; Trapman, B.K.; Kraan, M.L.

    2015-01-01

    The Cod monitoring program is part of the Dutch cod avoidance plan developed by the Dutch Government together with the Dutch fishing sector. The aim of this cod monitoring program is to provide information on the Catch per Unit Effort (CpUE) in the TR fleet (bottom trawls and seines). This is needed

  9. Cod monitoring : results 2015, quarter 2

    NARCIS (Netherlands)

    Teal, L.R.; Reijden, van der K.J.; Machiels, M.A.M.; Kraan, M.L.

    2015-01-01

    The Cod monitoring program is part of the Dutch cod avoidance plan developed by the Dutch Government together with the Dutch fishing sector. The aim of this cod monitoring program is to provide information on the Catch per Unit Effort (CpUE) in the TR fleet (bottom trawls and seines). This is needed

  10. Treatment of Synthetic Wastewater by Aerobic¬-anaerobic Bioreactor with Granular Sludge Developed for Removal of Nutrients

    Directory of Open Access Journals (Sweden)

    Malihe Amini

    2014-05-01

    Full Text Available The excessive accumulation of nutrient (C, N, and P discharge to surface water can pose serious ecological problems that affect the health of aquatic life and consequently that of human and animals. It is, therefore, necessary to remove these substances from wastewaters for reducing their harm to environments. A novel upflow aerobic/anoxic flocculated sludge bioreactor (UAASB will be establish and apply as a single treatment unit for carbon, nitrogen and phosphorus removal. In this study, nutrients (C, N and P removal efficiency in a time-based control UAASB reactor has studied. Analyze of nutrients removal efficiency were investigated from wastewater using optimization of factors and effects of variables: COD/N/P ratio and flow rate. Results of experiments showed that COD/N/P ratio 1000/250/2 and Q 7 L/h in HRT 6 h, F/M 0.054 kg COD/kg MLVSS.h and OLR 0.15 kg/m3.h were desirable for removal of nutrients from wastewater in aerobic/anaerobic bioreactor. In these conditions SVI 53.12 mL/g, COD removal efficiency 86% and PO43- removal efficiency 97.5% were showed. According all results of responses for best nutrient removal, UAASB bioreactor is desirable for removal efficiency of C and P.

  11. Improved removal performance and mechanism investigation of papermaking wastewater treatment using manganese enhanced Fenton reaction.

    Science.gov (United States)

    Wang, Yingcai; Wang, Can; Shi, Shuai; Fang, Shuai

    2018-06-01

    The effects of Mn(II) on Fenton system to treat papermaking wastewater and the mechanism of Mn(II) enhanced Fenton reaction were investigated in this study. The chemical oxygen demand (COD) removal efficiency was enhanced in the presence of Mn(II), which increased by 19% compared with that of the Fenton system alone. The pseudo-first order reaction kinetic rate constant of Mn(II)/Fenton system was 2.11 times higher than that of Fenton system. 67%-81% COD were removed with the increasing Mn(II) concentration from 0 to 0.8 g/L. COD removal efficiency was also enhanced in a wider pH range (3-7), which indicated the operation parameters of Fenton technology could be broadened to a milder condition. The study of the mechanism showed that Mn(II) participated in the oxidation and coagulation stages in Fenton system. In the oxidation stage, Mn(II) promotes the production of HO 2 •/ O 2 • - , then HO 2 •/ O 2 • - reacts with Fe(III) to accelerate the formation of Fe(II), and finally accelerates the production of HO•. Meantime MnMnO 3 and Fe(OH) 3 forms in the coagulation stage, facilitating the removal of suspended substances and a large amount of COD, which enhances the overall COD removal of papermaking wastewater. This study provided a detailed mechanism to improve practical applications of Fenton technology.

  12. The Effect of H2O2 Interference in Chemical Oxygen Demand Removal During Advanced Oxidation Processes

    Directory of Open Access Journals (Sweden)

    Afsane Chavoshani

    2016-07-01

    Full Text Available Hydrogen peroxide (H2O2 is one of the most oxidants in AOPs. By H2O2 dissociation, hydroxyl radical with a standard oxidation potential of 2.7 is produced. It is reported H2O¬ residual in AOPs has been led to interference in chemical oxygen demand (COD test and it is able to hinder biological treatment of waste water. Because of high mixed organic load of solid waste leachate, this study investigated effect of H2O2 interference in COD removal from solid waste leachate. In this study effect of parameters such as pH (3,5,7,12, H2O2 dose (0.01, 0.02, 0.03, 0.04 mol l-1, and time reaction(10,20,30,40,50,60 min evaluated on H2O2 interference in COD removal from solid waste leachate. Optimum pH and concentration were 3 and 0.02 moll-1 respectively. With increasing reaction time, COD removal was increased. The false COD obtained between 0.49mg per 1mg of H2O2. The average of COD removal by H2O2 for 60 min was 6.57%. Also reaction rate of this process was 0.0029 min-1. The presence of H2O2 leads to overestimation of COD values after reaction time because it consumes the oxidation agent. The extent of H2O2 interference in COD analysis was proportional to the remaining H2O2 concentration at the moment of sampling.

  13. Algae-facilitated chemical phosphorus removal during high-density Chlorella emersonii cultivation in a membrane bioreactor.

    Science.gov (United States)

    Xu, Meng; Bernards, Matthew; Hu, Zhiqiang

    2014-02-01

    An algae-based membrane bioreactor (A-MBR) was evaluated for high-density algae cultivation and phosphorus (P) removal. The A-MBR was seeded with Chlorella emersonii and operated at a hydraulic retention time of 1day with minimal biomass wastage for about 150days. The algae concentration increased from initially 385mg/L (or 315mg biomass COD/L) to a final of 4840mg/L (or 1664mg COD/L), yielding an average solids (algae biomass+minerals) production rate of 32.5gm(-3)d(-1) or 6.2gm(-2)d(-1). The A-MBR was able to remove 66±9% of the total P from the water while the algal biomass had an average of 7.5±0.2% extracellular P and 0.4% of intracellular P. The results suggest that algae-induced phosphate precipitation by algae is key to P removal and high-density algae cultivation produces P-rich algal biomass with excellent settling properties. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Microbial nitrate removal in biologically enhanced treated coal gasification wastewater of low COD to nitrate ratio by coupling biological denitrification with iron and carbon micro-electrolysis.

    Science.gov (United States)

    Zhang, Zhengwen; Han, Yuxing; Xu, Chunyan; Ma, Wencheng; Han, Hongjun; Zheng, Mengqi; Zhu, Hao; Ma, Weiwei

    2018-04-21

    Mixotrophic denitrification coupled biological denitrification with iron and carbon micro-electrolysis (IC-ME) is a promising emerging bioprocess for nitrate removal of biologically enhanced treated coal gasification wastewater (BECGW) with low COD to nitrate ratio. TN removal efficiency in R1 with IC-ME assisted was 16.64% higher than R2 with scrap zero valent iron addition, 23.05% higher than R3 with active carbon assisted, 30.51% higher than R4 with only active sludge addition, 80.85% higher than R5 utilizing single IC-ME as control. Fe 2+ generated from IC-ME decreased the production of N 2 O and enriched more Nitrate-reducing Fe(Ⅱ) oxidation bacteria (NRFOB) Acidovorax and Thiobacillus, which could convert nitrate to nitrogen gas. And the presence of Fe 3+ , as the Fe 2+ oxidation product, could stimulate the growth of Fe(III)-reducing strain (FRB) that indicated by redundancy analysis. Microbial network analysis demonstrated FRB Geothrix had a co-occurrence relationship with other bacteria, revealing its dominant involvement in nitrate removal of BECGW. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Organic Removal Efficiency of the Nanofiltration and Adsorption Hybrid System in High Strength Wastewater

    Directory of Open Access Journals (Sweden)

    Amir Hessam Hassani

    2011-03-01

    Full Text Available Surface and groundwater resources are increasingly jeopardized by discharges from pharmaceutical, chemical, and detergent plants. The high pollutant load of the effluents from these industries requires specific treatments. The objective of this research was to study and compare the nanofiltration and adsorption hybrid system with the plain nanofiltration system in wastewater treatment.For this purpose, a pilot nanofiltration system with a capacity of 7.6 m3/d using 1 and 5 micron filters and a FILMTEC NF90-4040 membrane was used in the first phase of the study. In the second phase, granular activated carbon cartridges were used. Inluent and effluent discharges as well as the COD removal were measured in both systems under variable times and organic load conditions. The results showed that COD removal efficiency was higher in the hybrid system than in the plain naonofiltration one. In the hybrid system, the Maximum in the hybrid system, the COD removal efficiencies achieved for organic loads of 1000, 2000, and 3000 mg/L were 99%, 95.86%, and 92.93%, respectively. The same values for the plain nanofiltration system were 87.34%, 50%, and 29.41%, respectively. It was found that polarization and membrane fouling decreased both the effluent flow and the COD removal efficiency with time. Fouling of the membrane was, however, lower in the hybrid system compared to the plain nanofiltration; thus, the hybrid system was associated with higher values of COD removal and delayed membrane fouling.

  16. AFSC/REFM: Pacific cod Localized Depletion Study

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Data from Localized Depletion study for Pacific cod 2001-2005. Study was conducted using cod pot gear to measure localized abundance of Pacific cod inside and...

  17. Coupling Fenton and biological oxidation for the removal of nitrochlorinated herbicides from water.

    Science.gov (United States)

    Sanchis, S; Polo, A M; Tobajas, M; Rodriguez, J J; Mohedano, A F

    2014-02-01

    The combination of Fenton and biological oxidation for the removal of the nitrochlorinated herbicides alachlor, atrazine and diuron in aqueous solution has been studied. The H2O2 dose was varied from 20 to 100% of the stoichiometric amount related to the initial chemical oxygen demand (COD). The effluents from Fenton oxidation were analyzed for ecotoxicity, biodegradability, total organic carbon (TOC), COD and intermediate byproducts. The chemical step resulted in a significant improvement of the biodegradability in spite of its negligible or even slightly negative effect on the ecotoxicity. Working at 60% of the stoichiometric H2O2 dose allowed obtaining highly biodegradable effluents in the cases of alachlor and atrazine. That dose was even lower (40% of the stoichiometric) for diuron. The subsequent biological treatment was carried out in a sequencing batch reactor (SBR) and the combined Fenton-biological treatment allowed up to around 80% of COD reduction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Removal of nutrients and veterinary antibiotics from swine wastewater by a constructed macrophyte floating bed system.

    Science.gov (United States)

    Xian, Qiming; Hu, Lixia; Chen, Hancheng; Chang, Zhizhou; Zou, Huixian

    2010-12-01

    The potential of three varieties of Italian ryegrass (Lolium multiflorum Lam.), Dryan, Tachimasari and Waseyutaka, to improve the water quality of swine wastewater was evaluated using a constructed macrophyte floating bed system. With respect to reductions in levels of nutrients, chemical oxygen demand (COD), and sulfonamide antimicrobials (SAs, including sulfadiazine, sulfamethazine, and sulfamethoxazole), Dryan performed better than Tachimasari and Waseyutaka. For Dryan, total N was reduced by 84.0%, total P by 90.4%, COD by 83.4% and sulfonamide antimicrobials by 91.8-99.5%. Similar results were observed for Tachimasari and Waseyutaka. The results indicated that the treatment of swine wastewater using the constructed macrophyte floating bed system was effective in the removal of nutrients and veterinary antibiotics. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Optimization study for Pb(II) and COD sequestration by consortium of sulphate-reducing bacteria

    Science.gov (United States)

    Verma, Anamika; Bishnoi, Narsi R.; Gupta, Asha

    2017-09-01

    In this study, initial minimum inhibitory concentration (MIC) of Pb(II) ions was analysed to check optimum concentration of Pb(II) ions at which the growth of sulphate-reducing consortium (SRC) was found to be maximum. 80 ppm of Pb(II) ions was investigated as minimum inhibitory concentration for SRC. Influence of electron donors such as lactose, sucrose, glucose and sodium lactate was examined to investigate best carbon source for growth and activity of sulphate-reducing bacteria. Sodium lactate was found to be the prime carbon source for SRC. Later optimization of various parameters was executed using Box-Behnken design model of response surface methodology to explore the effectiveness of three independent operating variables, namely, pH (5.0-9.0), temperature (32-42 °C) and time (5.0-9.0 days), on dependent variables, i.e. protein content, precipitation of Pb(II) ions, and removal of COD by SRC biomass. Maximum removal of COD and Pb(II) was observed to be 91 and 98 %, respectively, at pH 7.0 and temperature 37 °C and incubation time 7 days. According to response surface analysis and analysis of variance, the experimental data were perfectly fitted to the quadratic model, and the interactive influence of pH, temperature and time on Pb(II) and COD removal was highly significant. A high regression coefficient between the variables and response ( r 2 = 0.9974) corroborate eminent evaluation of experimental data by second-order polynomial regression model. SEM and Fourier transform infrared analysis was performed to investigate morphology of PbS precipitates, sorption mechanism and involved functional groups in metal-free and metal-loaded biomass of SRC for Pb(II) binding.

  20. Pollutant removal performance of an integrated upflow-constructed wetland filled with haydites made of Al-based drinking water treatment residuals.

    Science.gov (United States)

    Wang, Wendong; Han, Yu; Liu, Hui; Zhang, Ke; Yue, Qiang; Bo, Longli; Wang, Xiaochang

    2017-05-01

    This study examined the pollutants removal performance of an integrated upflow-constructed wetland (IUCW) system in a 1.5 years' continuous operation. The average concentrations of chemical oxygen demand (COD), NH 4 -N, total nitrogen (TN), and total phosphorus (TP) in the effluent were 21.9, 1.47, 2.63, and 0.18 mg/L, respectively, which corresponded to 90.1%, 23.3%, 86.1%, and 97.2% removals from the raw water, respectively. The residual concentration of COD was 219 mg/L at start-up and decreased notably to 52.8 mg/L after 50 days of operation. NH 4 -N was difficult to remove because the average concentration of dissolved oxygen in the IUCW system was lower than 0.6 mg/L. In contrast, the residual concentrations of both TN and TP in the effluent were stable, with average removal rates as high as 89% and 99%, respectively, at start-up of the system. Changing the organic loading rates from 45.0 g/(m 2 ·day) to 20.0 or 60.0 g/(m 2 ·day) both inhibited the removal of TN. Further study showed that the removal of organic matter mainly occurred within 10-20 cm of the wetland cell. Considering its strong organic, nitrogen, and phosphate removal capacity, the IUCW system was determined to be effective in decentralized wastewater treatment.

  1. Studies on Removal of Dyes from wastewater using Electro-coagulation Process

    OpenAIRE

    N B. Patel; B D. Soni; J P. Ruparelia

    2000-01-01

    Electro-coagulation (EC) is one of the effective techniques to remove colour, COD and organic compounds from wastewater. In this paper electro coagulation technique has been used for the removal of colour and COD from dye solutions containing Direct Black 22 and Acid Red 97 using batch process. For batch the process effect of operational parameters such as current density, initial pH of the solution, time of electrolysis and electrode materials were studied to attempt max...

  2. Chromium (VI) biosorption and removal of chemical oxygen demand by Spirulina platensis from wastewater-supplemented culture medium.

    Science.gov (United States)

    Magro, Clinei D; Deon, Maitê C; De Rossi, Andreia; Reinehr, Christian O; Hemkemeier, Marcelo; Colla, Luciane M

    2012-01-01

    The inappropriate discharge of wastewater containing high concentrations of toxic metals is a serious threat to the environment. Given that the microalga Spirulina platensis has demonstrated a capacity for chromium VI (Cr (VI) biosorption, we assessed the ideal concentration of chromium-containing wastewater required for maximum removal of Cr (VI) and chemical oxygen demand (COD) from the environment by using this microalga. The Paracas and Leb-52 strains of S. platensis, with initial wastewater concentrations of 0%, 12.5%, 25%, and 50%, were cultured in Zarrouk medium diluted to 50% under controlled air, temperature, and lighting conditions. The cultures were maintained for 28 days, and pH, biomass growth, COD, and Cr (VI) were assessed. The wastewater concentration influenced microalgal growth, especially at high concentrations. Removal of 82.19% COD and 60.92% Cr (VI) was obtained, but the COD removal was greater than the Cr (VI) removal in both strains of S. platensis.

  3. Explaining the catch efficiency of different cod pots using underwater video to observe cod entry and exit behaviour

    DEFF Research Database (Denmark)

    Hedgärde, Maria; Berg, Casper Willestofte; Kindt-Larsen, Lotte

    2016-01-01

    Cod pots are considered seal-safe fishing gear and are proposed as a solution to mitigate the ongoing seal-fisheries conflict in the Baltic Sea. This study examined various factors which could affect the entry and exit behaviour of cod in relation to cod pots. Statistical modelling was used...

  4. Bioelectricity generation and microcystins removal in a blue-green algae powered microbial fuel cell

    International Nuclear Information System (INIS)

    Yuan Yong; Chen Qing; Zhou Shungui; Zhuang Li; Hu Pei

    2011-01-01

    Bioelectricity production from blue-green algae was examined in a single chamber tubular microbial fuel cell (MFC). The blue-green algae powered MFC produced a maximum power density of 114 mW/m 2 at a current density of 0.55 mA/m 2 . Coupled with the bioenergy generation, high removal efficiencies of chemical oxygen demand (COD) and nitrogen were also achieved in MFCs. Over 78.9% of total chemical oxygen demand (TCOD), 80.0% of soluble chemical oxygen demand (SCOD), 91.0% of total nitrogen (total-N) and 96.8% ammonium-nitrogen (NH 3 -N) were removed under closed circuit conditions in 12 days, which were much more effective than those under open circuit and anaerobic reactor conditions. Most importantly, the MFC showed great ability to remove microcystins released from blue-green algae. Over 90.7% of MC-RR and 91.1% of MC-LR were removed under closed circuit conditions (500 Ω). This study showed that the MFC could provide a potential means for electricity production from blue-green algae coupling algae toxins removal.

  5. The eastern Baltic cod fishery: a fleet-based management strategy evaluation framework to assess the cod recovery plan of 2008

    DEFF Research Database (Denmark)

    Bastardie, Francois; Nielsen, J. Rasmus; Kraus, Gerd

    2010-01-01

    The eastern Baltic cod fishery: a fleet-based management strategy evaluation framework to assess the cod recovery plan of 2008. - ICES Journal of Marine Science, 67: 71-86.......The eastern Baltic cod fishery: a fleet-based management strategy evaluation framework to assess the cod recovery plan of 2008. - ICES Journal of Marine Science, 67: 71-86....

  6. N2O emissions from an intermittently aerated semi-aerobic aged refuse bioreactor: Combined effect of COD and NH4+-N in influent leachate.

    Science.gov (United States)

    Li, Weihua; Sun, Yingjie; Bian, Rongxing; Wang, Huawei; Zhang, Dalei

    2017-11-01

    The carbon-nitrogen ratio (COD/NH 4 + -N) is an important factor affecting nitrification and denitrification in wastewater treatment; this factor also influences nitrous oxide (N 2 O) emissions. This study investigated two simulated intermittently aerated semi-aerobic aged refuse bioreactors (SAARB) filled with 8-year old aged refuse (AR). The research analyzed how differences in and the combination of influent COD and NH 4 + -N impact N 2 O emissions in leachate treatment. Experimental results showed that N 2 O emissions increased as the influent COD/NH 4 + -N decreased. The influent COD had a greater effect on N 2 O emissions than NH 4 + -N at the same influent ratios of COD/NH 4 + -N (2.7 and 8.0, respectively). The maximum N 2 O emission accounted for 8.82±2.65% of the total nitrogen removed from the influent leachate; the maximum level occurred when the COD was 2000mg/L. An analysis of differences in influent carbon sources at the same COD/NH 4 + -N ratios concluded that the availability of biodegradable carbon substrates (i.e. glucose) is an important factor affecting N 2 O emissions. At a low influent COD/NH 4 + -N ratio (2.7), the N 2 O conversion rate was greater when there were more biodegradable carbon substrates. Although the SAARB included the N 2 O generation and reduction processes, N 2 O reduction mainly occurred later in the process, after leachate recirculation. The maximum N 2 O emission rate occurred in the first hour of single-period (24h) experiments, as leachate contacted the surface AR. In practical SAARB applications, N 2 O emissions may be reduced by measures such as reducing the initial recirculation loading of NH 4 + -N substrates, adding a later supplement of biodegradable carbon substrates, and/or prolonging hydraulic retention time (HRT) of influent leachate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Sequencing Batch Reactor (SBR) for the removal of Hg2+ and Cd2+ from synthetic petrochemical factory wastewater

    International Nuclear Information System (INIS)

    Malakahmad, Amirhossein; Hasani, Amirhesam; Eisakhani, Mahdieh; Isa, Mohamed Hasnain

    2011-01-01

    Highlights: → We assessed SBR performances to treat synthetic wastewater containing Hg 2+ and Cd 2+ . → SBR was able to remove 76-90% of Hg 2+ and 96-98% of Cd 2+ . → COD removal efficiency and MLVSS was affected by Hg 2+ and Cd 2+ concentrations. → Removal was not only biological process but also by biosorption process of sludge. - Abstract: Petrochemical factories which manufacture vinyl chloride monomer and poly vinyl chloride (PVC) are among the largest industries which produce wastewater contains mercury and cadmium. The objective of this research is to evaluate the performance of a lab-scale Sequencing Batch Reactor (SBR) to treat a synthetic petrochemical wastewater containing mercury and cadmium. After acclimatization of the system which lasted 60 days, the SBR was introduced to mercury and cadmium in low concentrations which then was increased gradually to 9.03 ± 0.02 mg/L Hg and 15.52 ± 0.02 mg/L Cd until day 110. The SBR performance was assessed by measuring Chemical Oxygen Demand, Total and Volatile Suspended Solids as well as Sludge Volume Index. At maximum concentrations of the heavy metals, the SBR was able to remove 76-90% of Hg 2+ and 96-98% of Cd 2+ . The COD removal efficiency and MLVSS (microorganism population) in the SBR was affected by mercury and cadmium concentrations in influent. Different species of microorganisms such as Rhodospirilium-like bacteria, Gomphonema-like algae, and sulfate reducing-like bacteria were identified in the system. While COD removal efficiency and MLVSS concentration declined during addition of heavy metals, the appreciable performance of SBR in removal of Hg 2+ and Cd 2+ implies that the removal in SBR was not only a biological process, but also by the biosorption process of the sludge.

  8. Efeito da taxa de carregamento sobre a remoção de poluentes de esgoto em sistemas alagados construídos Effect of loading rate on removal of pollutants from wastewater in constructed wetlands

    Directory of Open Access Journals (Sweden)

    Antonio T. de Matos

    2013-04-01

    Full Text Available Objetivou-se estudar o efeito da taxa de carregamento sobre a eficiência de sistemas alagados, construídos de escoamento horizontal subsuperficial (SAC-EHSS, em remover poluentes de esgoto sanitário. Os SAC-EHSS foram alimentados com efluente proveniente de tanque séptico, sob taxas de carregamento orgânico volumétrico (TCO V de 53 a 231 g m-3d-1 de demanda química de oxigênio (DQO total e as associadas taxas de carregamento (TC V de demanda química de oxigênio solúvel, sólidos suspensos totais (SST, nitrogênio total (N-Total e fósforo total (P-Total. Para avaliação de desempenho dos SAC-EHSS, as mesmas variáveis foram quantificadas em seu efluente. Relação linear e positiva foi obtida entre as taxas de remoção de DQO total, DQO solúvel e SST, e as TC V, nas faixas em que foram aplicadas, além de não terem sido observados efeitos negativos desta variável sobre a eficiência na remoção desses poluentes. As taxas de remoção de N-Total e P-Total não apresentaram, entretanto, tendência de aumento com a TC V aplicada nos SAC- EHSS, cultivados com taboa e utilizados no tratamento de efluente sanitário. As cargas aplicadas desses nutrientes devem ser consideradas referenciais no dimensionamento desses sistemas, caso se queira maximizar a remoção global de poluentes da água residuária.This research aimed to study the effect of loading rate on the efficiency of constructed wetlands with horizontal subsurface flow (CW-HSSF to remove pollutants from wastewater. The CW-HSSF were fed with effluent from septic tank under volumetric organic loading rate (OLR V of 53 to 231 g m-3d-1 of chemical oxygen demand (total-COD and associated loading rates (LR V of soluble chemical oxygen demand (soluble COD, total suspended solids (TSS, total nitrogen (total-N and total phosphorus (total-P. To evaluate the performance of CW-HSSF the same variables were quantified in its effluent. Linear and positive relationship was found between the

  9. Removal of organic pollutants from 2,2',5,5'-tetrachlorobenzidine (TCB) industrial wastewater by micro-electrochemical oxidation and air-stripping

    International Nuclear Information System (INIS)

    Xia Shibin; Xia Shuichun; Zhu Changqing

    2007-01-01

    A feasible method for treatment of the wastewater from the two-staged neutralization in 2,2',5,5'-tetrachlorobenzidine (TCB) manufacturing processes, a refractory dye intermediate effluents, based on combined micro-electrochemical oxidation or iron-chipping filtration (ICF) and air-stripping reactor (ASR), was developed. On conditions of HRT 1 h, pH 3.0 in ICF and HRT 38 h, gas-liquid ratio 15, pH 6.0-8.65, temperature 26 deg. C in ASR, the overall COD, color, TCB and NH 4 + -N removal were 96.8%, 91%, 87.61% and 62%, respectively, during the treatment of TCB wastewater from the two-staged neutralization dissolved by methanol. The averaged 18.3%, 81.7% of the total degraded COD, 35.2%, 64.8% of TCB were carried out in ICF and ASR, respectively. NH 4 + -N removal was finished mainly in ASR. The experimental results indicated that the combined micro-electrochemical oxidation and air-stripping process performed good treatment of COD, color, TCB and NH 4 + -N removal in TCB wastewater from the two-staged neutralization dissolved by ethanol or acetone, came up the discharge standard in China. But the TCB wastewater from the two-staged neutralization dissolved by methanol should be deeply treated before discharged

  10. Combined Pre-Precipitation, Biological Sludge Hydrolysis and Nitrogen Reduction - A Pilot Demonstration of Integrated Nutrient Removal

    DEFF Research Database (Denmark)

    Kristensen, G. H.; Jørgensen, P. E.; Strube, R.

    1992-01-01

    solubilization was 10-13% of the suspended COD. The liquid phase of the hydrolyzed sludge, the hydrolysate, was separated from the suspended fraction by centrifugation and added to the biological nitrogen removal stage to support denitrification. The hydrolysate COD consisted mainly of volatile fatty acids......A pilot study was performed to investigate advanced wastewater treatment by pre-precipitation in combination with biological nitrogen removal supported by biological sludge hydrolysis. The influent wastewater was pretreated by addition of a pre-polymerized aluminum salt, followed by flocculation......, resulting in high denitrification rates. Nitrogen reduction was performed based on the Bio-Denitro principle in an activated sludge system. Nitrogen was reduced from 45 mg/l to 9 mg/l and phosphorus was reduced from 11 mg/l to 0.5 mg/l. The sludge yield was low, approx. 0.3-0.4 gCOD/gCOD removed...

  11. Anaerobic treatment of cellulose bleach plant wastewater: chlorinated organics and genotoxicity removal

    Directory of Open Access Journals (Sweden)

    T. R. Chaparro

    2011-12-01

    Full Text Available This study assessed the removal efficiency of organic matter and how it relates to the decrease of toxic and mutagenic effects when an anaerobic reactor is used to treat the bleaching effluent from two kraft pulp mills. Parameters such as COD (chemical oxygen demand, DOC (dissolved organic carbon, AOX (adsorbable organic halogen, ASL (acid soluble lignin, color, chlorides, total phenols and absorbance values in the UV-VIS spectral region were measured. The acute and chronic toxicity and genetic toxicity assessments were performed with Daphnia similis, Ceriodaphnia sp. and Allium cepa L, respectively. The removal efficiency of organic matter measured as COD, ranged from 45% to 55%, while AOX removal ranged from 40% to 45%. The acute toxic and chronic effects, as well as the cytotoxic, genotoxic and mutagenic effects, decrease as the biodegradable fraction of the organics is removed. These results, together with the organic load measurement of the effluents of the anaerobic treatment, indicate that these effluents are recalcitrant but not toxic. As expected, color increased when the anaerobic treatment was applied. However, the colored compounds are of microbial origin and do not cause an increase in genotoxic effects. To discharge the wastewater, it is necessary to apply a physico-chemical or aerobic biological post-treatment to the effluents of the anaerobic reactor.

  12. Complejidad versus simplicidad en prótesis total removible

    OpenAIRE

    Escuin Henar, Tomás J. (Tomás José); Ferré de Guilarte, Antonio; Gascón Mayordomo, Francisco; Salsench Cabré, Juan

    1992-01-01

    En el presente trabajo valoramos los resultados a distancia (dos años) del método de elaboración de la Prótesis Total Removible, mediante la utilización de parámetros clínicos, con el fin de simplificar el proceso de elaboración de la Prótesis Total.

  13. The examination of the seasonal influence on the efficiency in oil and fats removal through primary treatment from the wastewater of edible oil industry

    Directory of Open Access Journals (Sweden)

    Nikolin Tatjana

    2014-01-01

    Full Text Available This paper investigates the influence of the seasonal change of the air temperature, chemical oxygen demand as well as efficiency of suspended matter removal on the efficiency of oil and fats removal (h, % during primary treatment. The parameters are monitored in the period of time from 2006 to 2011. The efficiency of oil and fats removal in the first and in the fourth quartal is proportional to the efficiency of the removal of suspended matter and of total organic matter, measured as chemical oxygen demand (COD. The measured values for oil and fat are: η (IV quartal = 0.96 % - 50.8 % and η (I quartal = 5.06 % - 95.97 %. The efficiency of oil and fats removal in the second and third quartal is proportional to air temperature so the measured efficiency of fat and oil removal are, η (II quartal = 3.93 % - 82.86 % and η (III quartal = 6.82% - 71.51%. The results of investigation have shown the existence of the correlation between the air temperature during various seasons and the efficiency of the oil and fats removal (h, % as well as the removal of the suspended matter and chemical oxygen demand (COD.

  14. Investigation of Electrocoagulation Process Efficiency for Color Removal from Polyacrylic Textile Industrial astewater

    Directory of Open Access Journals (Sweden)

    2013-08-01

    Full Text Available Dyes due to coloring nature are appearance pollutants and destroys the transparency and aesthetic quality of surface waters even at relatively low concentration. Several processes have been used for dye removal from wastewater. In recent years, electrochemical methods have been successfully employed to treat dying wastewater.In this study, the electrocoagulation method with aluminum electrodes were used for polyacrylic textile wastewater treatment. COD of wastewater was 1400mg/l. This study was conducted in laboratory scale. The sample was placed in to the electrochemical reactor contains 4 electrodes. The electrodes were connected to a DC power supply. Then the effect of the three operational parameters, electrolysis time (20-60 minutes, electrical applied current (0.5-2.5 Ampere and pH (4-9 on color and COD removal efficiency has been investigated. The results showed that the color and COD removal efficiency is a direct relation with increasing of the reaction time and inverse relation with increase of pH. Optimum operation conditions were in applied current of 1.5 A, the retention time of 60 minutes and pH of 4. In this condition, color and COD removals were 86% and 85%, respectively. This study showed that electrocoagulation process is an effective and efficient method to treatment of polyacrylic textile wastewater.

  15. Geologic history of Cape Cod, Massachusetts

    Science.gov (United States)

    ,

    1976-01-01

    Cape Cod, a sandy peninsula built mostly during the Ice Age, juts into the Atlantic Ocean like a crooked arm. Because of its exposed location, Cape Cod was visited by many early explorers. Although clear-cut evidence is lacking, the Vikings may have sighted this land about 1,000 years ago. It was visited by Samuel de Champlain in 1605, and his detailed descriptions and charts have helped present-day scientists to determine the rate of growth of Nauset Beach marsh and Nauset spit. Bartholomew Gosnold, a lesser known explorer, settled for a short time on the Elizabeth Islands to the southwest and gave Cape Cod its name in 1602. The Pilgrims first landed in America on the tip of Lower Cape Cod after they were turned back from their more southerly destination by shoals between Cape Cod and Nantucket Island. On Cape Cod they found potable water and food and had their first fight with the natives. The Pilgrims, however, decided that this land was too isolated, too exposed, and too sandy to support them, and they sailed across Cape Cod Bay to establish Plymouth. These features remain today. Small villages are separated by large areas of forest, dune, beach, and marsh. This unspoiled natural beauty makes Cape Cod one of the most favored vacation areas for the people living in the thickly settled Northeastern States. Cape Cod is of particular interest to geologists because it was formed by glaciers very recently in terms of geologic time. During the Great Ice Age, (the Pleistocene Epoch which began 2 to 3 million years ago), glaciers advanced from the north into the temperate regions of the Earth. Glacial ice covered the land at least four times. Each advance was accompanied by a worldwide lowering of sea level because the source of the ice was water from the seas. When the glaciers melted, the climate and sea level were probably much like they are today. In fact, some scientists believe that the Earth is presently between glacial episodes and that ice once again will

  16. Fluidized pellet bed bioreactor system for SS, COD, nitrogen and phosphorus; Ryudoso zoryu bio reactor system ni yoru SS, COD, chisso oyobi rin jokyo

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, T.; Tanbo, N.; Kudo, K. [Hokkaido University, Sapporo (Japan). Faculty of Engineering; Hamaguchi, T.; Nakabayashi, A. [Tsukishima Kikai Co. Ltd., Tokyo (Japan)

    1995-02-10

    An examination was carried out on a treatment system which was constituted of an aerobic fluidized pellet bed (AFRB) bioreactor and the two steps comprising a contact aeration process and a sand filtration process for sewage/drainage treatment. The following data were obtained from the experiment by a pilot plant installed in a sewage plant. The removal ratios were the same as or above 95% in SS, 95% in total phosphorus, 85% in COD and 80% in total nitrogen. The highly dense sludge pellets formed in the AFPB bioreactor in summer contained aerobic filamentous bacteria that were capable of multiplying. The sludge retention time of this bioreactor was 2.2 to 8.1 days which were sufficient for the multiplication of denitrifiers, whose number and activity were also satisfactory for dinitrification. Further, other microorganisms existed in the bioreactor such as sulfate reducers and methanation bacteria. The role of a contact aeration tank was the oxidized decomposition and nitration of soluble BOD, and the biofilm had niterite and nitrate bacteria adhered to it. Assuming the retention time of the tank was two hours, the nitration ratio was 90% or more at the water temperature of 15{degree}C or higher. 29 refs., 12 figs., 2 tabs.

  17. Host size-dependent anisakid infection in Baltic cod Gadus morhua associated with differential food preferences

    DEFF Research Database (Denmark)

    Zuo, Shaozhi; Huwer, Bastian; Bahlool, Qusay

    2016-01-01

    A significant increase in the infection level of Baltic cod Gadus morhua with the anisakid nematode larvae Contracaecum osculatum and Pseudoterranova decipiens has been recorded during recent years due to the expanding local population of grey seals Halichoerus grypus, which act as final hosts...... for these parasites. Here, we report from an investigation of 368 cod (total length [TL] 6-49 cm; caught in ICES Subdivision 25) that the infection level of juvenile cod (TL 6-30 cm) with larvae of C. osculatum and P. decipiens is absent or very low, whereas it increases drastically in larger cod (TL 31-48 cm...... suggest that the C. osculatum life cycle in the Baltic Sea includes grey seals as final hosts, sprat as the first transport host and cod as second transport host. It may be speculated that sprat obtain infection by feeding on copepods and/or cladocerans, which could serve as the first intermediate hosts...

  18. COD removal and biogas production at the manipueira treatment in anaerobic one-stage reactor with different supporting media; Remocao de DQO e producao de biogas no tratamento de manipueira em reator anaerobico monofasico com diferentes meios de suporte

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Douglas Guedes Batista; Kunzler, Kathia Regina; Gomes, Simone Damasceno; Tavares, Maria Herminia Ferreira; Assis, Tatiane Martins de [Universidade Estadual do Oeste do Parana (UNIOESTE), PR (Brazil)], Emails: simoned@unioeste.br, mhstavar@certto.com.br

    2009-07-01

    This study aims at evaluating the efficiency for organic load removal and biogas production for the manipueira treatment in two anaerobic reactors using as supporting media bamboo rings and polyurethane. The manipueira loads added to the systems were 0.548, 1.156, 1.471 and 3.049 g COD/ L{sub reactorday}, gradually increased. With bamboo as supporting media, the load increasing carried the greatest biogas production, with 3.049 g COD/ L{sub reactorday}. Using polyurethane, the greatest production occurred with the 1.471 g CODL{sub reactorday} {sup -1}load. Therefore, it was shown that the supporting media use allowed greater loads and biogas productions, comparatively to the literature data. (author)

  19. Comparison of Electrocoagulation and Chemical Coagulation Processes in Removing Reactive red 196 from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Ali Assadi

    2016-06-01

    Full Text Available Background: Conventional chemical coagulation is considered as an old method to dye and COD removal in textile effluent. Electrocoagulation (EC process is a robust method to achieve maximum removal. Methods: This study was designed to compare the result of operational parameters including optimum pH and coagulant concentration for chemical coagulation with ferric chloride and alum also, voltage, electrolysis time, initial pH, and conductivity for EC with iron electrodes to remove reactive red 196 (RR 196. Results: The outcomes show that ferric chloride and alum at optimum concentration were capable of removing dye and COD by 79.63 % and 84.83% and 53% and 55%, respectively. In contrast, EC process removed the dye and COD by 99.98% and 90.4%, respectively. Conclusion: The highest treatment efficiency was obtained by increasing the voltage, electrolysis time, pH and conductivity. Increase initial dye concentration reduces removal efficiency. Ultimately, it could be concluded that EC technology is an efficient procedure for handling of colored industrial wastewaters.

  20. Timing of Re-Transfusion Drain Removal Following Total Knee Replacement

    Science.gov (United States)

    Leeman, MF; Costa, ML; Costello, E; Edwards, D

    2006-01-01

    INTRODUCTION The use of postoperative drains following total knee replacement (TKR) has recently been modified by the use of re-transfusion drains. The aim of our study was to investigate the optimal time for removal of re-transfusion drains following TKR. PATIENTS AND METHODS The medical records of 66 patients who had a TKR performed between October 2003 and October 2004 were reviewed; blood drained before 6 h and the total volume of blood drained was recorded. RESULTS A total of 56 patients had complete records of postoperative drainage. The mean volume of blood collected in the drain in the first 6 h was 442 ml. The mean total volume of blood in the drain was 595 ml. Therefore, of the blood drained, 78% was available for transfusion. CONCLUSION Re-transfusion drains should be removed after 6 h, when no further re-transfusion is permissible. PMID:16551400

  1. Removal of the Inert Organic Fraction of Municipal Wastewater Using the Integrated Activated Sludge/Trickling Filter System

    Directory of Open Access Journals (Sweden)

    mehraban sadeghi

    2015-01-01

    Full Text Available The discharge of phenol and chlorinated compounds, fatty acids, tannin, lignin, and their by-products into receptive waters poses serious hazards for the aquatic life. In this study, the efficiency of a tow-step process of activated sludge-trickling filter (AS/TF in the removal of inert chemical materials that defy conventional treatment processes was investigated. For this purpose, an integrated activated sludge process (industrial scale was used sequentially with a trickling filter (pilot scale. Inside a tank with an effective volume of 6.87 m3 was installed 5.78 m3 of polypropylene 2HX media with a specific area of 240 m2/m3. The hydraulic loading rate (HLR of the trickling filter during the startup period (90 days was 3.6 m3/h which was raised to 3.6-6 m3/h in the operation period (120 days, with the best effluent quality achieved at HLR=5.4 m3/h. For the purposes of the experiments in this study, four reactors, each 1256 cm3 in volume, were fed the WWTP effluent and concurrently a glucose substrate containing a COD content equal to that fed to the four reactors was fed into two identical reactors; all the reactors were subsequently run for 480 h in aerobic conditions. Nutrients, pH, and DO (as environmental control indicators as well as soluble and total COD were measured twice daily. The effluent values of soluble inert materials (SI, total soluble COD (STO, degradable suspended materials (XSO, degradable COD (CSO, refractory suspended materials (XI, and degradable soluble materials (SSO for AS were calculated as 40, 227, 94, 281, 251, and 187, respectively, while the same parameters for the AS/TF were 20, 227, 104, 311, 241, and 207 mg/l, respectively. The results showed that the activated sludge process when combined with the trickling filter has a twofold capability, compared to when used alone, in removing inert COD. It was also shown that treatment levels in conventional WWTPs can be improved by integrating conventional treatment

  2. Sequencing Batch Reactor (SBR) for the removal of Hg{sup 2+} and Cd{sup 2+} from synthetic petrochemical factory wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Malakahmad, Amirhossein, E-mail: amirhossein@petronas.com.my [Faculty of Energy and Environmental Studies, Islamic Azad University, Science and Research branch, Hesarak, Tehran (Iran, Islamic Republic of); Civil Engineering Department, Universiti Teknologi PETRONAS, Tronoh, Perak (Malaysia); Hasani, Amirhesam [Faculty of Energy and Environmental Studies, Islamic Azad University, Science and Research branch, Hesarak, Tehran (Iran, Islamic Republic of); Eisakhani, Mahdieh [School of Social, Development and the Environment, Universiti Kebangsaan Malaysia, Bangi, Selangor (Malaysia); Isa, Mohamed Hasnain [Civil Engineering Department, Universiti Teknologi PETRONAS, Tronoh, Perak (Malaysia)

    2011-07-15

    Highlights: {yields} We assessed SBR performances to treat synthetic wastewater containing Hg{sup 2+} and Cd{sup 2+}. {yields} SBR was able to remove 76-90% of Hg{sup 2+} and 96-98% of Cd{sup 2+}. {yields} COD removal efficiency and MLVSS was affected by Hg{sup 2+} and Cd{sup 2+} concentrations. {yields} Removal was not only biological process but also by biosorption process of sludge. - Abstract: Petrochemical factories which manufacture vinyl chloride monomer and poly vinyl chloride (PVC) are among the largest industries which produce wastewater contains mercury and cadmium. The objective of this research is to evaluate the performance of a lab-scale Sequencing Batch Reactor (SBR) to treat a synthetic petrochemical wastewater containing mercury and cadmium. After acclimatization of the system which lasted 60 days, the SBR was introduced to mercury and cadmium in low concentrations which then was increased gradually to 9.03 {+-} 0.02 mg/L Hg and 15.52 {+-} 0.02 mg/L Cd until day 110. The SBR performance was assessed by measuring Chemical Oxygen Demand, Total and Volatile Suspended Solids as well as Sludge Volume Index. At maximum concentrations of the heavy metals, the SBR was able to remove 76-90% of Hg{sup 2+} and 96-98% of Cd{sup 2+}. The COD removal efficiency and MLVSS (microorganism population) in the SBR was affected by mercury and cadmium concentrations in influent. Different species of microorganisms such as Rhodospirilium-like bacteria, Gomphonema-like algae, and sulfate reducing-like bacteria were identified in the system. While COD removal efficiency and MLVSS concentration declined during addition of heavy metals, the appreciable performance of SBR in removal of Hg{sup 2+} and Cd{sup 2+} implies that the removal in SBR was not only a biological process, but also by the biosorption process of the sludge.

  3. Walking the cod: an investigation into the relative robustness of cod, Gadus morhua, skeletal elements

    Directory of Open Access Journals (Sweden)

    Andrew K.G. Jones

    1999-12-01

    Full Text Available A simple experiment is described which details what happens to the bones of cod when they are walked on by a man. The pattern of fragmentation for various elements is illustrated and an index of robustness proposed for those elements in a cod skeleton most frequently recovered from archaeological sites.

  4. Study of Slow Sand Filtration in Removing Total Coliforms and E.Coli

    Directory of Open Access Journals (Sweden)

    Ekha Yogafanny

    2015-08-01

    Full Text Available This study was aimed to evaluate the performance of SSF in removing bacteria (Total Coliforms and E. Coli in regard to grain size distribution and grain shape intermittently. Two methodological approaches used in this reasearch were literature review and laboratory work. Bacteria removal was analyzed considering two different filter media (Rhine sand-spherical shape and Lava sand-angular shape with three different grain size distributions. The best performance was attained by filter column F4 which consisted of Lava sand and had the configuration C2 (d10 = 0.07 mm; Cu = 4.2. This filter column achieved 4.7log-units removal of Total Coliforms and 5.0log-units removal of E. coli. The results show that a smaller grain size and an angular shape of sand grain lead to an increase in bacteria removal.

  5. Nitrogen and Organics Removal during Riverbank Filtration along a Reclaimed Water Restored River in Beijing, China

    Directory of Open Access Journals (Sweden)

    Weiyan Pan

    2018-04-01

    Full Text Available Reclaimed water has been widely used to restore rivers and lakes in water scarce areas as well as in Beijing municipality, China. However, refilling the rivers with reclaimed water may result in groundwater pollution. A three-year field monitoring program was conducted to assess the effect of a riverbank filtration (RBF system on the removal of nitrogen and organics from the Qingyang River of Beijing, which is replenished with reclaimed water. Water samples from the river, sediment, and groundwater were collected for NO3-N, NH4-N, and chemical oxygen demand (COD was measured. The results indicate that about 85% of NO3-N was removed from the riverbed sediments. Approximate 92% of NH4-N was removed during the infiltration of water from river to aquifer. On average, 54% of COD was removed by RBF. The attenuation of NO3-N through RBF to the groundwater varied among seasons and was strongly related to water temperature. On the other hand, no obvious temporal variability was identified in the removal of COD. These results suggest that the RBF system is an effective barrier against NO3-N, NH4-N and COD in the Qingyang River, as well as those rivers with similar geological and climatic conditions refilled with reclaimed water.

  6. CodY-Dependent Regulation of Sporulation in Clostridium difficile.

    Science.gov (United States)

    Nawrocki, Kathryn L; Edwards, Adrianne N; Daou, Nadine; Bouillaut, Laurent; McBride, Shonna M

    2016-08-01

    Clostridium difficile must form a spore to survive outside the gastrointestinal tract. The factors that trigger sporulation in C. difficile remain poorly understood. Previous studies have suggested that a link exists between nutritional status and sporulation initiation in C. difficile In this study, we investigated the impact of the global nutritional regulator CodY on sporulation in C. difficile strains from the historical 012 ribotype and the current epidemic 027 ribotype. Sporulation frequencies were increased in both backgrounds, demonstrating that CodY represses sporulation in C. difficile The 027 codY mutant exhibited a greater increase in spore formation than the 012 codY mutant. To determine the role of CodY in the observed sporulation phenotypes, we examined several factors that are known to influence sporulation in C. difficile Using transcriptional reporter fusions and quantitative reverse transcription-PCR (qRT-PCR) analysis, we found that two loci associated with the initiation of sporulation, opp and sinR, are regulated by CodY. The data demonstrate that CodY is a repressor of sporulation in C. difficile and that the impact of CodY on sporulation and expression of specific genes is significantly influenced by the strain background. These results suggest that the variability of CodY-dependent regulation is an important contributor to virulence and sporulation in current epidemic isolates. This report provides further evidence that nutritional state, virulence, and sporulation are linked in C. difficile This study sought to examine the relationship between nutrition and sporulation in C. difficile by examining the global nutritional regulator CodY. CodY is a known virulence and nutritional regulator of C. difficile, but its role in sporulation was unknown. Here, we demonstrate that CodY is a negative regulator of sporulation in two different ribotypes of C. difficile We also demonstrate that CodY regulates known effectors of sporulation, Opp and Sin

  7. PHOSPHATES REMOVAL FROM REJECT WATER FROM DIGESTION OF SLUDGE

    Directory of Open Access Journals (Sweden)

    Elżbieta Sperczyńska

    2016-06-01

    Full Text Available The aim of the research work was to evaluate if coagulants used on technical scale are useful in phosphates removal from reject water. Effectiveness of phosphorus compounds removal from reject water from digestion of sewage sludge was examined. Selected prehydrolysed alkaline aluminium polychlorides were used. The results were compared to the ones obtained with aluminium sulphate. Reject water from digestion of sewage sludge form WWTP of 100 000 PE were examined. Commercial agents – prehydrolysed PAX 18, PAX XL10, PAX-XL1905 as well as aluminium sulphate were used. Various doses of coagulants: 0.7; 1.0; 1.5 – time higher than stoichiometric dose were applied. Stoichiometric dose was calculated based on chemical reaction of insoluble aluminium phosphate formation. Concentrations of Kiejdahl nitrogen (891 mgNKj/dm3, phosphates (125 mgPO43-/dm3 and organic compounds - COD (592 mgO2/dm3 in reject water were very high. The effectiveness of coagulation process increased as the doses of chemical agents increased. The most effective doses were the highest ones used during the experiment. The most effective agent was PAX 18 (96% removal efficiency. As the phosphates concentration decreased COD content declined simultaneously. Maximum COD removal (47% was obtained when highly alkaline PAX XL 1905 was used. Use of the lowest dose of Al2(SO43 allowed for 50% phosphates removal, whereas the lowest dose of PAX 18 decreased phosphates concentration by 83%.

  8. Spatio-temporal dynamics of cod nursery areas in the Baltic Sea

    Science.gov (United States)

    Hinrichsen, H.-H.; von Dewitz, B.; Lehmann, A.; Bergström, U.; Hüssy, K.

    2017-06-01

    In this study the drift of eastern Baltic cod larvae and juveniles spawned within the historical eastern Baltic cod spawning grounds was investigated by detailed drift model simulations for the years 1971-2010, to examine the spatio-temporal dynamics of environmental suitability in the nursery areas of juvenile cod settlement. The results of the long-term model scenario runs, where juvenile cod were treated as simulated passively drifting particles, enabled us to find strong indications for long-term variations of settlement and potentially the reproduction success of the historically important eastern Baltic cod nursery grounds. Only low proportions of juveniles hatched in the Arkona Basin and in the Gotland Basin were able to settle in their respective spawning ground. Ocean currents were either unfavorable for the juveniles to reach suitable habitats or transported the juveniles to nursery grounds of neighboring subdivisions. Juveniles which hatched in the Bornholm Basin were most widely dispersed and showed the highest settlement probability, while the second highest settlement probability and horizontal dispersal was observed for juveniles originating from the Gdansk Deep. In a long-term perspective, wind-driven transport of larvae/juveniles positively affected the settlement success predominately in the Bornholm Basin and in the Bay of Gdansk. The Bornholm Basin has the potential to contribute on average 54% and the Bay of Gdansk 11% to the production of juveniles in the Baltic Sea. Furthermore, transport of juveniles surviving to the age of settlement with origin in the Bornholm Basin contributed on average 13 and 11% to the total settlement in the Arkona Basin and in the Gdansk Deep, respectively. The time-series of the simulated occupied juvenile cod habitat in the Bornholm Basin and in the Gdansk Deep showed a similar declining trend as the Fulton's K condition factor of demersal 1-group cod, which may confirm the importance of oxygen-dependent habitat

  9. Veratric acid removal from water by electrochemical oxidation on BDD anode

    Science.gov (United States)

    Jum'h, Inshad; Abdelhay, Arwa; Telfah, Ahmad; Al-Akhras, M.-Ali; Al-Kazwini, Akeel; Rosiwal, Stefan

    2018-02-01

    The efficiency of boron doped diamond (BDD) in the electrochemical treatment of synthetically contaminated water with veratric acid (VA), one kind of polyphenolic type compounds, is investigated in this work. A BDD electrode was practically fabricated using hot filament chemical vapor deposition (HFCVD). Later on, the BDD electrode was implemented as an anode in a batch electrolytic reactor. The effect of operating factors such as the initial concentration of VA, NaCl addition, and supporting electrolyte type (H2SO4, H3PO4 and Na2SO4) was studied. The chemical oxygen demand (COD) measurements were conducted to study the VA electrolysis kinetics. The experimental data suggested that sodium sulfate was the best supporting electrolyte as the COD removal reached a percentage of 100% using 1 mmol/dm3 as VA concentration. The kinetics of the COD decay of the VA electrolysis were found to obey the pseudo-first order model. Remarkably, the electrolysis process is significantly speeded up once chloride is added to the reaction. The complete COD removal was achieved in 60 minutes of treatment.

  10. Using interview-based recall surveys to estimate cod Gadus morhua and eel Anguilla anguilla harvest in Danish recreational fishing

    DEFF Research Database (Denmark)

    Sparrevohn, Claus Reedtz; Storr-Paulsen, Marie

    2012-01-01

    Using interview-based recall surveys to estimate cod Gadus morhua and eel Anguilla anguilla harvest in Danish recreational fishing. – ICES Journal of Marine Science, 69: 323–330.Marine recreational fishing is a popular outdoor activity in Denmark, practised by both anglers and passive gear fishers....... However, the impact on the targeted stocks is unknown, so to estimate the 2009 harvest of cod Gadus morhua and eel Anguilla anguilla, two separate interview-based surveys were initiated and carried out in 2009/2010. The first recall survey exclusively targeted fishers who had been issued......, in certain areas, the recreational harvest of cod accounted for more than 30% of the total yield. The majority (81%) of the recreational cod harvest was taken by anglers. Eels, however, are almost exclusively caught with passive gear (fykenets) and a total of 104 t year−1 was harvested, which corresponds...

  11. Use of calcined layered double hydroxides for the removal of color and organic matter from textile effluents: kinetic, equilibrium and recycling studies

    Directory of Open Access Journals (Sweden)

    T. P. F. Teixeira

    2014-03-01

    Full Text Available This paper presents data for the synthesis and characterization of layer double hydroxides (LDH and their use for color and chemical oxygen demand (COD removal from effluents generated by a textile industry. Adsorption studies with raw and biologically treated (activated sludge textile effluent showed that the pseudo-second order model best fitted the experimental data, leading to adsorption coefficients of 39.1 and 102.9 mgCOD/gLDH for raw and treated effluents, respectively. The best conditions for color and COD removal were obtained at lower values of temperature and pH (25 °C and pH 7 and, in these conditions, an LDH dose of 10 g/L resulted in color removal efficiencies of 56% for samples of raw and 66% for samples of treated effluent. Recycling studies indicated that the reuse of thermally treated LDH led to a progressive loss in the removal efficiencies of COD and color. The reduction was more pronounced with samples of the raw textile effluent. LDH characterization performed before and after each adsorption and regeneration experiment showed that there was no intercalation of dye molecules in the interlayer region of the LDH, indicating that COD and color removal might be due to the adsorption of organic molecules onto the LDH surface.

  12. Removal of hazardous dye congored from waste material

    International Nuclear Information System (INIS)

    Jain, Rajeev; Sikarwar, Shalini

    2008-01-01

    The present paper is aimed to investigate and develop cheap adsorption methods for color removal from wastewater using waste material sawdust as adsorbent. Sawdust, a biosorbent, was successfully utilized in removing a water soluble azo dye, congored from wastewater. The paper incorporates effect of pH, temperature, amount of adsorbent, contact time, concentration of adsorbate, particle size on adsorption. Specific rate constants of the processes were calculated by kinetic measurements and a first order adsorption kinetics was observed in each case. Langmuir and Freundlich adsorption isotherm models were then applied to calculate thermodynamics parameters as well as to suggest the plausible mechanism of the ongoing adsorption processes. In order to observe the quality of wastewater COD measurements were also carried out before and after the treatments. A significant decrease in the COD values was observed, which clearly indicates that adsorption method offer good potential to remove congored from wastewater

  13. Effectiveness of pollutants removal in hybrid constructed wetlands – different configurations case study

    Directory of Open Access Journals (Sweden)

    Gajewska Magdalena

    2017-01-01

    Full Text Available In recent years, an increase in interest in hybrid constructed wetland systems (HCWs has been observed. The aim of the paper is to compare different HCW configurations in terms of mass removal rates and efficiency of pollutants removal. Analysed data have been collected at multistage constructed wetlands in Poland, which are composed by at least two beds: horizontal subsurface flow (SSHF and vertical subsurface flow (SSVF. The evaluation was focused on hybrid constructed wetlands performance with HF+VF vs. VF+HF configuration, where influent wastewater of the same composition was treated. In analysed HCWs, the effective removal of organic matter from 75.2 to 91.6% COD was confirmed. Efficiency of total nitrogen removal varied from 47.3 to 91.7%. The most effective removal of TN (8.3 g m−2 d−1 occurred in the system with VF+VF+HF configuration.

  14. 76 FR 73513 - Fisheries of the Exclusive Economic Zone Off Alaska; Revisions to Pacific Cod Fishing in the...

    Science.gov (United States)

    2011-11-29

    ... term of the permit. Third, it requires an operator of any Federally permitted pot or hook-and-line C/P... catching a greater amount of Pacific cod in the parallel fishery than has been allocated to their sector from the BSAI total allowable catch. Maintaining Pacific cod catch amounts within BSAI sector...

  15. Preparation, Characterization and Adsorption Study of Granular Activated Carbon/Iron oxide composite for the Removal of Boron and Organics from Wastewater

    Directory of Open Access Journals (Sweden)

    Affam Augustine Chioma

    2018-01-01

    Full Text Available Boron and organics maybe in high concentration during production of oil and gas, fertilizers, glass, and detergents. In addition, boron added to these industrial processes may require to be removed by the wastewater treatment plant. The preparation, characterization and application of iron oxide-activated carbon composite for removal of boron and COD was studied. The one variable at a time (OVAT method was implemented to obtain desirable operating conditions (adsorbent dosage 5 g/L, reaction time 2 h, agitation speed 100 rpm, pH 5 for COD removal and pH 9 for boron removal. It was found that boron and organics present in a sample wastewater may require to be treated separately to remove the contaminants. The study achieved 97 and 70% for boron and COD removal, respectively. Adsorption as an alternative cheap source of treatment and its practicability for small communities is recommended as effective in removal of contaminants from river water.

  16. Preparation, Characterization and Adsorption Study of Granular Activated Carbon/Iron oxide composite for the Removal of Boron and Organics from Wastewater

    Science.gov (United States)

    Chioma Affam, Augustine; Chung Wong, Chee; Seyam, Mohammed A. B.; Matt, Chelsea Ann Anak Frederick; Lantan Anak Sumbai, Josephine; Evuti, Abdullahi Mohammed

    2018-03-01

    Boron and organics maybe in high concentration during production of oil and gas, fertilizers, glass, and detergents. In addition, boron added to these industrial processes may require to be removed by the wastewater treatment plant. The preparation, characterization and application of iron oxide-activated carbon composite for removal of boron and COD was studied. The one variable at a time (OVAT) method was implemented to obtain desirable operating conditions (adsorbent dosage 5 g/L, reaction time 2 h, agitation speed 100 rpm, pH 5 for COD removal and pH 9 for boron removal). It was found that boron and organics present in a sample wastewater may require to be treated separately to remove the contaminants. The study achieved 97 and 70% for boron and COD removal, respectively. Adsorption as an alternative cheap source of treatment and its practicability for small communities is recommended as effective in removal of contaminants from river water.

  17. [Assessment of production of eggs of Eastern Baltic cod (Gadus morhua callarias L.) on the basis of long-term ichthyoplankton data].

    Science.gov (United States)

    Karaseva, E M

    2011-01-01

    Proceeding from long-term data on the numbers of eggs of cod in ichthyoplankton, the total annual production of cod eggs at four main spawning grounds of the Baltic Sea was calculated. It was shown that the long-term fluctuations of cod egg production were positively related to the dynamics of the volume of waters coming to the Baltic Sea in years of the North Sea advections. It is suggested that this dependence was determined by a set of adaptations providing the extension of cod reproduction upon the improvement of the environment.

  18. Early Removal of Drainage Tube after Fast-Track Primary Total Knee Arthroplasty.

    Science.gov (United States)

    Zhang, Shaoyun; Xu, Bin; Huang, Qiang; Yao, Huan; Xie, Jinwei; Pei, Fuxing

    2017-07-01

    There is no consensus as to whether drainage tube should be used and how long it should remain in use after primary total knee arthroplasty (TKA). As fast-track (FT) program has been implemented in TKA, whether drainage tube could be removed early, and the ideal timing for removal after FT primary TKA has been a new topic. The purpose of this prospective cohort study was to evaluate the safety and feasibility of early removal of drainage tube when FT program was implemented in primary TKA. A total of 101 patients undergoing FT primary TKA were prospectively allocated into three groups. Patients in group A (31 patients) indwelled wound drainage tube for 6 hours after surgery while group B (34 patients) for 12 hours and group C (36 patients) for 18 hours. The knee circumference, resting and moving visual analogue score (VAS), hemoglobin (Hb), hematocrit, white blood count (WBC), erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), interleukin-6 (IL-6), the volume of blood loss and drainage, and postoperative length of stay (LOS) among three groups were recorded and compared. There was no statistically significant difference in the volume of total and hidden blood loss among three groups ( p  > 0.05), but as the time of drainage prolonged, total volume of drainage and dominant blood loss increased gradually ( p   0.05), the decrease of Hb in the perioperative period and postoperative LOS as well. Early removal of wound drainage tube could drain the hematocele and reduce the risk of infection, and it doesn't increase the sense of pain, inflammatory reaction, limb swelling, and total blood loss. It's safe and feasible to remove the drainage tube within 6 to 12 hours after FT primary TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Organic pollutants removal from 2,4,6-trinitrotoluene (TNT) red water using low cost activated coke

    Institute of Scientific and Technical Information of China (English)

    Mohe Zhang; Quanlin Zhao; Zhengfang Ye

    2011-01-01

    We treated 2,4,6-trinitrotoluene (TNT) red water from the Chinese explosive industry with activated coke (AC) from lignite.Since the composition of TNT red water was very complicated,chemical oxygen demand (COD) was used as the index for evaluating treatment efficiency.This study focused on sorption kinetics and equilibrium sorption isotherms of AC for the removal of COD from TNT red water,and the changes of water quality before and after adsorption were evaluated using high performance liquid chromatography,UV-Vis spectra and gas chromatography/mass spectroscopy.The results showed that the sorption kinetics of COD removal from TNT red water onto AC fitted well with the pseudo second-order model.The adsorption process was an exothermic and physical process.The sorption isotherm was in good agreement with Redlich-Peterson isotherm.At the conditions of initial pH =6.28,20°C and 3 hr of agitation,under 160 g/L AC,64.8% of COD was removed.The removal efficiencies of 2,4-dinitrotoluene-3-sulfonate (2,4-DNT-3-SO3-) and 2,4-dinitrotoluene-5-sulfonate (2,4-DNT-5-SO3-) were 80.5% and 84.3%,respectively.After adsorption,the acute toxicity of TNT red water reduced greatly,compared with that of unprocessed TNT red water.

  20. Preparation of Ti/IrO2 Anode with Low Iridium Content by Thermal Decomposition Process: Electrochemical removal of organic pollutants in water

    Science.gov (United States)

    Yaqub, Asim; Isa, Mohamed Hasnain; Ajab, Huma; Kutty, S. R. M.; Ezechi, Ezerie H.; Farooq, Robina

    2018-04-01

    In this study IrO2 (Iridium oxide) was coated onto a titanium plate anode from a dilute (50 mg/10 ml) IrCl3×H2O salt solution. Coating was done at high temperature (550∘C) using thermal decomposition. Surface morphology and characteristics of coated surface of Ti/IrO2 anode were examined by FESEM and XRD. The coated anode was applied for electrochemical removal of organic pollutants from synthetic water samples in 100 mL compartment of batch electrochemical cell. About 50% COD removal was obtained at anode prepared with low Ir content solution while 72% COD removal was obtained with anode prepared at high Ir content. Maximum COD removal was obtained at 10 mA/cm2 current density.

  1. Between Localization and Delocalization: Ru(cod)2+ Units in the Zintl Clusters [Bi9 {Ru(cod)}2 ]3- and [Tl2 Bi6 {Ru(cod)}]2.

    Science.gov (United States)

    Lichtenberger, Niels; Spang, Nils; Eichhöfer, Andreas; Dehnen, Stefanie

    2017-10-16

    Reactions of [K(crypt-222)] 2 (TlBi 3 )⋅0.5 en (1 b) with [Ru(cod)(H 2 CC(Me)CH 2 ) 2 ] (A) in 1,2-diaminoethane (en) led to the formation of two compounds with new bismuth-rich cluster anions, [K(crypt-222)] 3 [Bi 9 {Ru(cod)} 2 ]⋅1.5 en (2) and [K(crypt-222)] 2 [Tl 2 Bi 6 {Ru(cod)}]⋅2 tol (3), alongside the salt of a binary nido cluster, [K(crypt-222)] 3 (Tl 4 Bi 5 )⋅2 en (4). The anions in 2 and 3 are two further examples of rare heterometallic clusters containing Ru atoms. As one cod ligand is retained on each Ru atom in both clusters, the anions may be viewed as intermediates on the way towards larger, ligand-free intermetalloid clusters. Quantum-chemical studies provided insight into the bonding situation in these clusters. According to these studies, the anion of 2 features both electron-precise and electron-deficient parts. Electrospray ionization mass spectrometry analysis indicated that the clusters undergo stepwise fragmentation. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Selective haddock (Melanogrammus aeglefinus) trawling: Avoiding cod (Gadus morhua) bycatch

    DEFF Research Database (Denmark)

    Krag, Ludvig Ahm; Holst, René; Madsen, Niels

    2010-01-01

    The critical condition of the North Sea cod stocks has resulted in restrictions on not only cod, but also haddock and other species that are caught together with cod. Thus full exploitation of the haddock stock is unachievable unless cod can be excluded from the haddock catch. We designed a selec...... dependent: smaller cod escaped the trawl in greater numbers than did larger individuals. Whiting, saithe. lemon sole, and plaice were included in the analysis. (C) 2009 Elsevier B.V. All rights reserved....

  3. Recalcitrant Compounds Removal in Raw Leachate and Synthetic Effluents Using the White-Rot Fungus Bjerkandera adusta

    Directory of Open Access Journals (Sweden)

    Alessandra Bardi

    2017-10-01

    Full Text Available Recalcitrant compounds limit the efficiency of conventional biological processes for wastewater treatment, representing one of the major issues in the field. This study focused on the treatment of three effluents with White-Rot-Fungus (WRF Bjerkandera adusta MUT 2295 in batch tests, with biomass cultivated in attached form on polyurethane foam cubes (PUFs to test its efficiency in the removal of the target effluents’ recalcitrant fraction. Treatment efficiency of B. adusta was evaluated on landfill leachate (Canada and two solutions containing synthetic recalcitrant compounds, which were prepared with tannic and humic acid. Chemical Oxygen Demand (COD and color removal, the production of manganese peroxidases, and the consumption of a co-substrate (glucose were monitored during the experiment. Biological Oxygen Demand (BOD5 and fungal dry weight were measured at the beginning and at the end of the experiment. After co-substrate addition, effluent COD was 2300 ± 85, 2545 ± 84, and 2580 ± 95 (mg/L in raw leachate and tannic and humic acids, respectively. COD removal of 48%, 61%, and 48% was obtained in raw leachate and in the synthetic effluents containing tannic and humic acids, respectively. Color removal of 49%, 25%, and 42% was detected in raw leachate and in tannic and humic acid solutions, respectively. COD and color removals were associated with the increase of fungal dry weight, which was observed in all the trials. These results encourage the use of the selected fungal strain to remove tannic acid, while further investigations are required to optimize leachate and humic acid bioremediation.

  4. COD removal characteristics in air-cathode microbial fuel cells

    KAUST Repository

    Zhang, Xiaoyuan; He, Weihua; Ren, Lijiao; Stager, Jennifer; Evans, Patrick J.; Logan, Bruce E.

    2015-01-01

    © 2014 Elsevier Ltd. Exoelectrogenic microorganisms in microbial fuel cells (MFCs) compete with other microorganisms for substrate. In order to understand how this affects removal rates, current generation, and coulombic efficiencies (CEs

  5. Characterization of Atlantic cod spawning habitat and behavior in Icelandic coastal waters.

    Directory of Open Access Journals (Sweden)

    Timothy B Grabowski

    Full Text Available The physical habitat used during spawning may potentially be an important factor affecting reproductive output of broadcast spawning marine fishes, particularly for species with complex, substrate-oriented mating systems and behaviors, such as Atlantic cod Gadus morhua. We characterized the habitat use and behavior of spawning Atlantic cod at two locations off the coast of southwestern Iceland during a 2-d research cruise (15-16 April 2009. We simultaneously operated two different active hydroacoustic gear types, a split beam echosounder and a dual frequency imaging sonar (DIDSON, as well as a remotely operated underwater vehicle (ROV. A total of five fish species were identified through ROV surveys: including cusk Brosme brosme, Atlantic cod, haddock Melanogrammus aeglefinus, lemon sole Microstomus kitt, and Atlantic redfish Sebastes spp. Of the three habitats identified in the acoustic surveys, the transitional habitat between boulder/lava field and sand habitats was characterized by greater fish density and acoustic target strength compared to that of sand or boulder/lava field habitats independently. Atlantic cod were observed behaving in a manner consistent with published descriptions of spawning. Individuals were observed ascending 1-5 m into the water column from the bottom at an average vertical swimming speed of 0.20-0.25 m s(-1 and maintained an average spacing of 1.0-1.4 m between individuals. Our results suggest that cod do not choose spawning locations indiscriminately despite the fact that it is a broadcast spawning fish with planktonic eggs that are released well above the seafloor.

  6. Characterization of Atlantic cod spawning habitat and behavior in Icelandic coastal waters

    Science.gov (United States)

    Grabowski, Timothy B.; Boswell, Kevin M.; McAdam, Bruce J.; Wells, R. J. David; Marteinsdóttir, Gudrún

    2012-01-01

    The physical habitat used during spawning may potentially be an important factor affecting reproductive output of broadcast spawning marine fishes, particularly for species with complex, substrate-oriented mating systems and behaviors, such as Atlantic cod Gadus morhua. We characterized the habitat use and behavior of spawning Atlantic cod at two locations off the coast of southwestern Iceland during a 2-d research cruise (15–16 April 2009). We simultaneously operated two different active hydroacoustic gear types, a split beam echosounder and a dual frequency imaging sonar (DIDSON), as well as a remotely operated underwater vehicle (ROV). A total of five fish species were identified through ROV surveys: including cusk Brosme brosme, Atlantic cod, haddock Melanogrammus aeglefinus, lemon sole Microstomus kitt, and Atlantic redfish Sebastes spp. Of the three habitats identified in the acoustic surveys, the transitional habitat between boulder/lava field and sand habitats was characterized by greater fish density and acoustic target strength compared to that of sand or boulder/lava field habitats independently. Atlantic cod were observed behaving in a manner consistent with published descriptions of spawning. Individuals were observed ascending 1–5 m into the water column from the bottom at an average vertical swimming speed of 0.20–0.25 m s−1 and maintained an average spacing of 1.0–1.4 m between individuals. Our results suggest that cod do not choose spawning locations indiscriminately despite the fact that it is a broadcast spawning fish with planktonic eggs that are released well above the seafloor.

  7. The effect of external dummy transmitters on oxygen consumption and performance of swimming Atlantic cod

    DEFF Research Database (Denmark)

    Steinhausen, M.F.; Andersen, Niels Gerner; Steffensen, J.F.

    2006-01-01

    Decreased critical swimming speed and increased oxygen consumption (Mo-2) was found for externally tagged Atlantic cod Gadus morhua swimming at a high speed of 0 center dot 9 body length (total length, L-Gamma) s(-1). No difference was found in the standard metabolic rate, indicating...... that the higher Mo-2 for tagged cod was due to drag force rather than increased costs to keep buoyancy. (c) 2006 The Authors Journal compilation (c) 2006 The Fisheries Society of the British Isles....

  8. Larval and small juvenile cod Gadus morhua concentrated in the highly productive areas of a shelf break front

    DEFF Research Database (Denmark)

    Munk, Peter; Larsson, P.O.; Danielsen, D.

    1995-01-01

    describe the identified nursery areas of larvae/juveniles and analyse the connection between the distribution of cod and hydrographical (frontal) characteristics of the areas. A total area of 67000 km(2) was covered by stations in a 10 x 10 nautical mile grid. Salinity, temperature, NO3+NO2 and chlorophyll...... part of the investigation area, and within the zone of the front we observed enhanced primary production and abundance of both phyto- and zooplankton. The distribution of larval and juvenile cod was also related to the hydrography, the abundance of cod peaked within a restricted zone...

  9. Sensory characteristics of different cod products

    DEFF Research Database (Denmark)

    Sveinsdottir, K.; Martinsdottir, E.; Hyldig, Grethe

    2010-01-01

    atmosphere) were evaluated with quantitative descriptive analysis by a trained sensory panel. Signal-to-noise analysis, p*MSE (discrimination and repeatability) and line plots proved to be very useful in studying panelists' performance. Most sensory attributes described significant differences between...... the products, and principal component analysis provided an overview of the differences and similarities between the products with regard to sensory characteristics. Farmed cod had different sensory characteristics compared with wild cod, such as more meat flavor, and rubbery and meaty texture. Different...... storage methods had minor influence on sensory characteristics of cod fillets after short storage time, but after extended storage, the groups were different with regard to most attributes. PRACTICAL APPLICATIONS This paper presents different ways of analyzing sensory data. The process of analysis...

  10. Nitrogen removal from landfill leachate via ex situ nitrification and sequential in situ denitrification

    International Nuclear Information System (INIS)

    Zhong Qi; Li Daping; Tao Yong; Wang Xiaomei; He Xiaohong; Zhang Jie; Zhang Jinlian; Guo Weiqiang; Wang Lan

    2009-01-01

    Ex situ nitrification and sequential in situ denitrification represents a novel approach to nitrogen management at landfills. Simultaneous ammonia and organics removal was achieved in a continuous stirred tank reactor (CSTR). The results showed that the maximum nitrogen loading rate (NLR) and the maximum organic loading rate (OLR) was 0.65 g N l -1 d -1 and 3.84 g COD l -1 d -1 , respectively. The ammonia and chemical oxygen demand (COD) removal was over 99% and 57%, respectively. In the run of the CSTR, free ammonia (FA) inhibition and low dissolved oxygen (DO) were found to be key factors affecting nitrite accumulation. In situ denitrification was studied in a municipal solid waste (MSW) column by recalculating nitrified leachate from CSTR. The decomposition of MSW was accelerated by the recirculation of nitrified leachate. Complete reduction of total oxidized nitrogen (TON) was obtained with maximum TON loading of 28.6 g N t -1 TS d -1 and denitrification was the main reaction responsible. Additionally, methanogenesis inhibition was observed while TON loading was over 11.4 g N t -1 TS d -1 and the inhibition was enhanced with the increase of TON loading

  11. Removal of nutrients in denitrification system using coconut coir fibre for the biological treatment of aquaculture wastewater.

    Science.gov (United States)

    Manoj, Valsa Remony; Vasudevan, Namasivayam

    2012-03-01

    Ideal bacterial support medium for fixed film denitrification processes/bioreactors must be inexpensive, durable and possess large surface area with sufficient porosity. The present study has been focussed on removing nitrate nitrogen at two different nitrate nitrogen loading rates (60 (NLR I) and 120 (NLR II) mg l(-1)) from simulated aquaculture wastewater. Coconut coir fibre and a commercially available synthetic reticulated plastic media (Fujino Spirals) were used as packing medium in two independent upflow anaerobic packed bed column reactors. Removal of nitrate nitrogen was studied in correlation with other nutrients (COD, TKN, dissolved orthophosphate). Maximum removal of 97% at NLR-I and 99% at NLR - II of nitrate nitrogen was observed in with either media. Greater consistency in the case of COD removal of upto 81% was observed at NLR II where coconut coir was used as support medium compared to 72% COD removal by Fujino Spirals. The results observed indicate that the organic support medium is just as efficient in nitrate nitrogen removal as conventionally used synthetic support medium. The study is important as it specifically focuses on denitrification of aquaculture wastewater using cheaper organic support medium in anoxic bioreactors for the removal of nitrate nitrogen; which is seldom addressed as a significant problem.

  12. 77 FR 8177 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Pot Gear in the...

    Science.gov (United States)

    2012-02-14

    ... Using Pot Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using pot gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using pot gear in...

  13. 77 FR 14305 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Jig Gear in the...

    Science.gov (United States)

    2012-03-09

    ... Using Jig Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using jig gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using jig gear in...

  14. 77 FR 6683 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Pot Gear in the...

    Science.gov (United States)

    2012-02-09

    ... Using Pot Gear in the Western Regulatory Area of the Gulf of Alaska AGENCY: National Marine Fisheries...; closure. SUMMARY: NMFS is prohibiting directed fishing for Pacific cod by vessels using pot gear in the... season allowance of the 2012 Pacific cod total allowable catch apportioned to vessels using pot gear in...

  15. Anaerobic biodegradability and treatment of grey water in upflow anaerobic sludge blanket (UASB) reactor.

    Science.gov (United States)

    Elmitwalli, Tarek A; Otterpohl, Ralf

    2007-03-01

    Feasibility of grey water treatment in an upflow anaerobic sludge blanket (UASB) reactor operated at different hydraulic retention time (HRT) of 16, 10 and 6h and controlled temperature of 30 degrees C was investigated. Moreover, the maximum anaerobic biodegradability without inoculum addition and maximum removal of chemical oxygen demand (COD) fractions in grey water were determined in batch experiments. High values of maximum anaerobic biodegradability (76%) and maximum COD removal in the UASB reactor (84%) were achieved. The results showed that the colloidal COD had the highest maximum anaerobic biodegradability (86%) and the suspended and dissolved COD had similar maximum anaerobic biodegradability of 70%. Furthermore, the results of the UASB reactor demonstrated that a total COD removal of 52-64% was obtained at HRT between 6 and 16 h. The UASB reactor removed 22-30% and 15-21% of total nitrogen and total phosphorous in the grey water, respectively, mainly due to the removal of particulate nutrients. The characteristics of the sludge in the UASB reactor confirmed that the reactor had a stable performance. The minimum sludge residence time and the maximum specific methanogenic activity of the sludge ranged between 27 and 93 days and 0.18 and 0.28 kg COD/(kg VS d).

  16. Biogas-pH automation control strategy for optimizing organic loading rate of anaerobic membrane bioreactor treating high COD wastewater.

    Science.gov (United States)

    Yu, Dawei; Liu, Jibao; Sui, Qianwen; Wei, Yuansong

    2016-03-01

    Control of organic loading rate (OLR) is essential for anaerobic digestion treating high COD wastewater, which would cause operation failure by overload or less efficiency by underload. A novel biogas-pH automation control strategy using the combined gas-liquor phase monitoring was developed for an anaerobic membrane bioreactor (AnMBR) treating high COD (27.53 g·L(-1)) starch wastewater. The biogas-pH strategy was proceeded with threshold between biogas production rate >98 Nml·h(-1) preventing overload and pH>7.4 preventing underload, which were determined by methane production kinetics and pH titration of methanogenesis slurry, respectively. The OLR and the effluent COD were doubled as 11.81 kgCOD·kgVSS(-1)·d(-1) and halved as 253.4 mg·L(-1), respectively, comparing with a constant OLR control strategy. Meanwhile COD removal rate, biogas yield and methane concentration were synchronously improved to 99.1%, 312 Nml·gCODin(-1) and 74%, respectively. Using the biogas-pH strategy, AnMBR formed a "pH self-regulation ternary buffer system" which seizes carbon dioxide and hence provides sufficient buffering capacity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Removal of COD and TSS From Dye Solution Using Sand Filtration and Adsorption

    Directory of Open Access Journals (Sweden)

    Heny Juniar

    2016-11-01

    Full Text Available This research was conducted in order to obtain proper compositions and the standard condition for the simple filtration equipments and optimum operational conditions in adsorption column. The research was carried out by analyzing parameters COD and TSS. The result showed that the process was able to reduced parameters observed from filtration step until the process in adsorptions column. The optimum conditions for sand filter equipment were 10 cm sand height, at least 7 cm fibers, 3-4 cm gravel. In the adsorption column, the optimum conditions for green waste water were flow rate at 40 ml/min 60 min adsorptions time, and 60 cm bed height. While purple for waste water; 20 mL/min of flowrate, 60 min of adsorption time, and the 60 cm of bed height

  18. COD correction for laser cooling at S-LSR

    International Nuclear Information System (INIS)

    Souda, Hikaru; Fujimoto, Shinji; Tongu, Hiromu; Shirai, Toshiyuki; Tanabe, Mikio; Ishikawa, Takehiro; Nakao, Masao; Ikegami, Masahiro; Wakita, Akihisa; Iwata, Soma; Fujimoto, Tetsuya; Takeuchi, Takeshi; Noda, Koji; Noda, Akira

    2008-01-01

    A closed orbit is corrected for single-turn injection to perform laser cooling experiments of 40 keV 24 Mg + beam at the small laser-equipped storage ring (S-LSR). Closed orbit distortion (COD) corrections have been carried out using a downhill simplex method, and CODs of less than ±0.5mm have been achieved throughout the whole circumference. The injection orbit and the CODs are optimized to pass through the two aperture holes in the alignment targets located in the laser cooling section with an algorithm to maximize beam lifetime. The CODs at the aperture holes are reduced to be less than ±0.2mm, assuring an overlap between the laser and the 24 Mg + ion beam.

  19. Nitrogen removal from coal gasification wastewater by activated carbon technologies combined with short-cut nitrogen removal process.

    Science.gov (United States)

    Zhao, Qian; Han, Hongjun; Hou, Baolin; Zhuang, Haifeng; Jia, Shengyong; Fang, Fang

    2014-11-01

    A system combining granular activated carbon and powdered activated carbon technologies along with shortcut biological nitrogen removal (GAC-PACT-SBNR) was developed to enhance total nitrogen (TN) removal for anaerobically treated coal gasification wastewater with less need for external carbon resources. The TN removal efficiency in SBNR was significantly improved by introducing the effluent from the GAC process into SBNR during the anoxic stage, with removal percentage increasing from 43.8%-49.6% to 68.8%-75.8%. However, the TN removal rate decreased with the progressive deterioration of GAC adsorption. After adding activated sludge to the GAC compartment, the granular carbon had a longer service-life and the demand for external carbon resources became lower. Eventually, the TN removal rate in SBNR was almost constant at approx. 43.3%, as compared to approx. 20.0% before seeding with sludge. In addition, the production of some alkalinity during the denitrification resulted in a net savings in alkalinity requirements for the nitrification reaction and refractory chemical oxygen demand (COD) degradation by autotrophic bacteria in SBNR under oxic conditions. PACT showed excellent resilience to increasing organic loadings. The microbial community analysis revealed that the PACT had a greater variety of bacterial taxons and the dominant species associated with the three compartments were in good agreement with the removal of typical pollutants. The study demonstrated that pre-adsorption by the GAC-sludge process could be a technically and economically feasible method to enhance TN removal in coal gasification wastewater (CGW). Copyright © 2014. Published by Elsevier B.V.

  20. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands.

    Science.gov (United States)

    Morvannou, Ania; Troesch, Stéphane; Esser, Dirk; Forquet, Nicolas; Petitjean, Alain; Molle, Pascal

    2017-07-01

    French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2-2.5 m 2 /P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter ® is one of the solutions developed in France by Epur Nature. Biho-Filter ® is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study was to assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho-Filter ® plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter ® configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD 5 ), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/NO 3 -N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.

  1. Removal of anaerobic soluble microbial products in a biological activated carbon reactor.

    Science.gov (United States)

    Dong, Xiaojing; Zhou, Weili; He, Shengbing

    2013-09-01

    The soluble microbial products (SMP) in the biological treatment effluent are generally of great amount and are poorly biodegradable. Focusing on the biodegradation of anaerobic SMP, the biological activated carbon (BAC) was introduced into the anaerobic system. The experiments were conducted in two identical lab-scale up-flow anaerobic sludge blanket (UASB) reactors. The high strength organics were degraded in the first UASB reactor (UASB1) and the second UASB (UASB2, i.e., BAC) functioned as a polishing step to remove SMP produced in UASB1. The results showed that 90% of the SMP could be removed before granular activated carbon was saturated. After the saturation, the SMP removal decreased to 60% on the average. Analysis of granular activated carbon adsorption revealed that the main role of SMP removal in BAC reactor was biodegradation. A strain of SMP-degrading bacteria, which was found highly similar to Klebsiella sp., was isolated, enriched and inoculated back to the BAC reactor. When the influent chemical oxygen demand (COD) was 10,000 mg/L and the organic loading rate achieved 10 kg COD/(m3 x day), the effluent from the BAC reactor could meet the discharge standard without further treatment. Anaerobic BAC reactor inoculated with the isolated Klebsiella was proved to be an effective, cheap and easy technical treatment approach for the removal of SMP in the treatment of easily-degradable wastewater with COD lower than 10,000 mg/L.

  2. Influence of chlorothalonil on the removal of organic matter in horizontal subsurface flow constructed wetlands.

    Science.gov (United States)

    Casas-Zapata, Juan C; Ríos, Karina; Florville-Alejandre, Tomás R; Morató, Jordi; Peñuela, Gustavo

    2013-01-01

    This study investigates the effects of chlorothalonil (CLT) on chemical oxygen demand (COD) and dissolved organic carbon (DOC) in pilot-scale horizontal subsurface flow constructed wetlands (HSSFCW) planted with Phragmites australis. Physicochemical parameters of influent and effluent water samples, microbial population counting methods and statistical analysis were used to evaluate the influence of CLT on organic matter removal efficiency. The experiments were conducted on four planted replicate wetlands (HSSFCW-Pa) and one unplanted control wetland (HSSFCW-NPa). The wetlands exhibited high average organic matter removal efficiencies (HSSFCW-Pa: 80.6% DOC, 98.0% COD; HSSFCW-NPa: 93.2% DOC, 98.4% COD). The addition of CLT did not influence organic removal parameters. In all cases CLT concentrations in the effluent occurred in concentrations lower than the detection limit of the analytical method. Microbial population counts from HSSFCW-Pa showed significant correlations among different microbial groups and with different physicochemical variables. The apparent independence of organic matter removal and CLT inputs, along with the CLT depletion observed in effluent samples demonstrated that HSSFCW are a viable technology for the treatment of agricultural effluents contaminated with organo-chloride pesticides like CLT.

  3. CodY-mediated regulation of Streptococcus pyogenes exoproteins

    Directory of Open Access Journals (Sweden)

    McDowell Emily J

    2012-06-01

    Full Text Available Abstract Background The production of Streptococcus pyogenes exoproteins, many of which contribute to virulence, is regulated in response to nutrient availability. CodY is a transcriptional regulator that controls gene expression in response to amino acid availability. The purpose of this study was to identify differences in the expression of streptococcal exoproteins associated with deletion of the codY gene. Results We compared the secreted proteins produced by wild-type S. pyogenes to a codY mutant in the post-exponential phase of growth. We used both one and two-dimensional gel electrophoresis to separate exoproteins. Proteins that were significantly different in abundance upon repeated analysis were identified with tandem mass spectrometry. The production of the secreted cysteine protease SpeB, a secreted chromosomally encoded nuclease (SdaB, and a putative adhesion factor (Spy49_0549 were more abundant in supernatant fluids obtained from the codY mutant. In addition, hyaluronidase (HylA, CAMP factor (Cfa, a prophage encoded nuclease (Spd-3, and an uncharacterized extracellular protein (Spy49_0015 were less abundant in supernatant fluids obtained from the codY mutant strain. Enzymatic assays showed greater DNase activity in culture supernatants isolated in the post-exponential phase of growth from the codY mutant strain compared to the wild-type strain. Because extracellular nucleases and proteases can influence biofilm formation, we also measured the ability of the strains to form biofilms during growth with both rich medium (Todd Hewitt yeast extract; THY and chemically defined media (CDM. No difference was observed with rich media but with CDM the biofilms formed by the codY mutant strain had less biomass compared to the wild-type strain. Conclusions Overall, the results indicate that CodY alters the abundance of a select group of S. pyogenes exoproteins, including DNases, a protease, and hylauronidase, which together may alleviate

  4. Preozonation Effect on Total Organic Carbon Removal in Surface Water Treatment

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2006-06-01

    Full Text Available In drinking water treatment, preozonation is often applied in order to control the microorganisms and taste and odor causing materials, which may influence organics removal by preoxidation and adsorption. Using commercial and natural water humic substances, the positive effect of preozonation as an aid to coagulation-flocculation of these compounds was confirmed by removal of TOC removal in Tehranpars Water Treatment Plant in Tehran. These experiments were conducted as bench-scale studies through a series of jar tests using different pH coagulant dosages and total organic carbon concentration of approximately 4, 8 and 12 mg/L. In addition to TOC removal, the existence of an optimum preozonation dose (OPZD was also confirmed. Experiments show that preozonation can improve coagulation and flocculation depending on influent TOC concentration of raw water. The results demonstrate different effects of preozonation on removal of influent TOC. Preozonation showed a positive effect on a system with low influent TOC and very low molecular weight (noncolloidal humic substances.

  5. Feeding opportunities of larval and juvenile cod (Gadus morhua) in a Greenlandic fjord: temporal and spatial linkages between cod and their preferred prey

    DEFF Research Database (Denmark)

    Swalethorp, Rasmus; Kjellerup, Sanne; Malanski, Evandro

    2014-01-01

    preferences of the early-life stages of Atlantic cod (Gadus morhua) to quantify the availability of prey during a spring-summer season in a West Greenlandic fjord. We hypothesized that abundances of larval and juvenile cod at size were synchronized to optimal availability of preferred prey in space and time....... These findings stress the importance of focusing on abundance of preferred prey when assessing the actual prey availability to young fish. We found a spatio-temporal overlap between cod and their preferred prey, and observations suggest that advection of both zooplankton and cod contributed to this overlap...

  6. Removal of an endocrine disrupting chemical (17 alpha-ethinyloestradiol) from wastewater effluent by activated carbon adsorption: Effects of activated carbon type and competitive adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Ifelebuegu, A.O.; Lester, J.N.; Churchley, J.; Cartmell, E. [Cranfield University, Cranfield (United Kingdom). School of Water Science

    2006-12-15

    Granular activated carbon has been extensively used for the adsorption of organic micropollutants for potable water production. In this study the removal of an endocrine disrupting chemical from wastewater final effluent by three types of granular activated carbon (wood, coconut and coal based) has been investigated in batch adsorption experiments and correlated with the removal of chemical oxygen demand (COD), total organic carbon (TOC) and ultraviolet absorbance (UV). The results obtained demonstrated 17 alpha-ethinyloestradiol (EE2) removals of 98.6%, 99.3%, and 96.4% were achieved by the coal based (ACo), coconut based (ACn) and wood based (AWd) carbons respectively at the lowest dose of carbon (0.1 gl{sup -1}). The other adsorbates investigated all exhibited good removal. At an equilibrium concentration of 7 mgl{sup -1} the COD adsorption capacities were 3.16 mg g{sup -1}, 4.8 mg g{sup -1} and 7.1 mg g{sup -1} for the wood, coconut and coal based carbons respectively. Overall, the order of removal efficiency of EE2 and the other adsorbates for the three activated carbons was ACn {gt} ACo {gt} AWd. The adsorption capacities of the carbons were found to be reduced by the effects of other competing adsorbates in the wastewater effluent.

  7. Male reproductive competition in spawning aggregations of cod ( Gadus morhua , L.)

    DEFF Research Database (Denmark)

    Bekkevold, Dorte; Hansen, Michael Møller; Loeschcke, V.

    2002-01-01

    Reproductive competition may lead to a large skew in reproductive success among individuals. Very few studies have analysed the paternity contribution of individual males in spawning aggregations of fish species with huge census population sizes. We quantified the variance in male reproductive...... success in spawning aggregations of cod under experimental conditions over an entire spawning season. Male reproductive success was estimated by microsatellite-based parentage analysis of offspring produced in six separate groups of spawning cod. In total, 1340 offspring and 102 spawnings distributed...... across a spawning season were analysed. Our results show that multiple males contributed sperm to most spawnings but that paternity frequencies were highly skewed among males, with larger males on average siring higher proportions of offspring. It was further indicated that male reproductive success...

  8. Effect of COD/N ratio on N2O production during nitrogen removal by aerobic granular sludge.

    Science.gov (United States)

    Velho, V F; Magnus, B S; Daudt, G C; Xavier, J A; Guimarães, L B; Costa, R H R

    2017-12-01

    N 2 O-production was investigated during nitrogen removal using aerobic granular sludge (AGS) technology. A pilot sequencing batch reactor (SBR) with AGS achieved an effluent in accordance with national discharge limits, although presented a nitrite accumulation rate of 95.79% with no simultaneous nitrification-denitrification. N 2 O production was 2.06 mg L -1 during the anoxic phase, with N 2 O emission during air pulses and the aeration phase of 1.6% of the nitrogen loading rate. Batch tests with AGS from the pilot reactor verified that at the greatest COD/N ratio (1.55), the N 2 O production (1.08 mgN 2 O-N L -1 ) and consumption (up to 0.05 mgN 2 O-N L -1 ), resulted in the lowest remaining dissolved N 2 O (0.03 mgN 2 O-N L -1 ), stripping the minimum N 2 O gas (0.018 mgN 2 O-N L -1 ). Conversely, the carbon supply shortage, under low C/N ratios, increased N 2 O emission (0.040 mgN 2 O-N L -1 ), due to incomplete denitrification. High abundance of ammonia-oxidizing and low abundance of nitrite-oxidizing bacteria were found, corroborating the fact of partial nitrification. A denitrifying heterotrophic community, represented mainly by Pseudoxanthomonas, was predominant in the AGS. Overall, the AGS showed stable partial nitrification ability representing capital and operating cost savings. The SBR operation flexibility could be advantageous for controlling N 2 O emissions, and extending the anoxic phase would benefit complete denitrification in cases of low C/N influents.

  9. The removal efficiency of constructed wetlands filled with the zeolite-slag hybrid substrate for the rural landfill leachate treatment.

    Science.gov (United States)

    He, Hailing; Duan, Zhiwei; Wang, Zhenqing; Yue, Bo

    2017-07-01

    The removal efficiencies of two horizontal subsurface flow constructed wetlands (HSSF CWs, down-flow (F1) and up-flow (F2)) filled with the zeolite-slag hybrid substrate for the rural landfill leachate treatment were investigated. The adsorption experiment was conducted to evaluate the potential of zeolite and slag as the wetland substrate. The effects of distance variations along the longitudinal profile of wetland bed on pollutant removal were assessed by sampling at four locations (inlet, outlet, 0.55 m, and 1.10 m from the inlet). During the operation time, the influent and effluent concentrations of chemical oxygen demand (COD), ammonia nitrogen (NH 3 -N), total nitrogen (TN), heavy metals, and polycyclic aromatic hydrocarbon (PAH) were measured. The results showed that the constructed wetlands were capable of removing COD, 20.5-48.2% (F1) and 18.6-61.2% (F2); NH 3 -N, 84.0-99.9% (F1) and 93.5-99.2% (F2); TN, 80.3-92.1% (F1) and 80.3-91.2% (F2); and heavy metals, about 90% (F1 and F2). The zeolite-slag hybrid substrate performed excellent removal efficiency for the nitrogen and heavy metals. The inlet area was the most active region of leachate removal. The up-flow constructed wetland (F2) has a higher removal efficiency for the PAH compounds. The significant removal efficiency illustrated that the rural landfill leachate can be treated using the horizontal subsurface flow constructed wetland filled with the zeolite-slag hybrid substrate.

  10. Decolorization and COD reduction of UASB pretreated poultry manure wastewater by electrocoagulation process: A post-treatment study

    International Nuclear Information System (INIS)

    Yetilmezsoy, Kaan; Ilhan, Fatih; Sapci-Zengin, Zehra; Sakar, Suleyman; Gonullu, M. Talha

    2009-01-01

    The performance of electrocoagulation (EC) technique for decolorization and chemical oxygen demand (COD) reduction of anaerobically pretreated poultry manure wastewater was investigated in a laboratory batch study. Two identical 15.7-L up-flow anaerobic sludge blanket (UASB) reactors were first run under various organic and hydraulic loading conditions for 216 days. Effects of operating parameters such as type of sacrificial electrode material, time of electrolysis, current density, initial pH, and electrolyte concentration were further studied to optimize conditions for the post-treatment of UASB pretreated poultry manure wastewater. Preliminary tests conducted with two types of sacrificial electrodes (Al and Fe) resulted that Al electrodes were found to be more effective for both COD and color removals than Fe electrodes. The subsequent EC tests performed with Al electrodes showed that optimal operating conditions were determined to be an initial pH of 5.0, a current density of 15 mA/cm 2 , and an electrolysis time of 20 min. The results indicated that under the optimal conditions, about 90% of COD and 92% of residual color could be effectively removed from the UASB effluent with the further contribution of the EC technology used as a post-treatment unit. In this study, the possible acute toxicity of the EC effluent was also evaluated by a static bioassay test procedure using guppy fish (Lebistes reticulatus). Findings of this study clearly indicated that incorporation of a toxicological test into conventional physicochemical analyses provided a better evaluation of final discharge characteristics

  11. Decolorization and COD reduction of UASB pretreated poultry manure wastewater by electrocoagulation process: A post-treatment study

    Energy Technology Data Exchange (ETDEWEB)

    Yetilmezsoy, Kaan [Department of Environmental Engineering, Yildiz Technical University, 34349 Yildiz, Besiktas, Istanbul (Turkey)], E-mail: yetilmez@yildiz.edu.tr; Ilhan, Fatih; Sapci-Zengin, Zehra; Sakar, Suleyman; Gonullu, M. Talha [Department of Environmental Engineering, Yildiz Technical University, 34349 Yildiz, Besiktas, Istanbul (Turkey)

    2009-02-15

    The performance of electrocoagulation (EC) technique for decolorization and chemical oxygen demand (COD) reduction of anaerobically pretreated poultry manure wastewater was investigated in a laboratory batch study. Two identical 15.7-L up-flow anaerobic sludge blanket (UASB) reactors were first run under various organic and hydraulic loading conditions for 216 days. Effects of operating parameters such as type of sacrificial electrode material, time of electrolysis, current density, initial pH, and electrolyte concentration were further studied to optimize conditions for the post-treatment of UASB pretreated poultry manure wastewater. Preliminary tests conducted with two types of sacrificial electrodes (Al and Fe) resulted that Al electrodes were found to be more effective for both COD and color removals than Fe electrodes. The subsequent EC tests performed with Al electrodes showed that optimal operating conditions were determined to be an initial pH of 5.0, a current density of 15 mA/cm{sup 2}, and an electrolysis time of 20 min. The results indicated that under the optimal conditions, about 90% of COD and 92% of residual color could be effectively removed from the UASB effluent with the further contribution of the EC technology used as a post-treatment unit. In this study, the possible acute toxicity of the EC effluent was also evaluated by a static bioassay test procedure using guppy fish (Lebistes reticulatus). Findings of this study clearly indicated that incorporation of a toxicological test into conventional physicochemical analyses provided a better evaluation of final discharge characteristics.

  12. Nutrient Removal of Grey Water from Wet Market Using Sequencing Batch Reactor

    International Nuclear Information System (INIS)

    Omar Danial; Mohd Razman Salim; Salmiati

    2016-01-01

    Fresh water scarcity has become an important issue in this world today. Water reuse is known as one of the strategies to overcome this problem. Grey water is one of the sources of reused water. Several researches were carried out on water reuse, but limited attention was focused on reusing grey water from wet market, which contains high nutrient and organic matters. This study was carried out on nutrient removal from grey water using sequencing batch reactor (SBR). The grey water sample was taken from a wet market (Pasar Peladang, Skudai). About 1L of grey water was fed into the reactor with a total volume of 4L. Anoxic-aerobic phase were divided with a ratio of 30 % - 70 % of total time respectively. Mixing was maintained at 30 rpm during the start of each cycle until settling phase to achieve uniform condition. Influent and effluent were set for 30 minutes. The SBR was operated with 3 cycles/ day, temperature 30 degree Celsius, cycle time 8 hours and hydraulic retention time (HRT) 1.2 days. Aeration at 35 L/ min was induced for ammonia conversion and assisting nitrification.. The results show that the bacteria growing in alternating anoxic/ aerobic systems could remove organic substrates and nutrient. The COD, Total Nitrogen and Total Phosphorus removal efficiencies were maximum at the levels of 94 %, 88 % and 70 % respectively. Anaerobic-Aerobic-Anoxic phase was proposed to increase the removal percentage. (author)

  13. Relationships between water quality parameters in rivers and lakes: BOD5, COD, NBOPs, and TOC.

    Science.gov (United States)

    Lee, Jaewoong; Lee, Seunghyun; Yu, Soonju; Rhew, Doughee

    2016-04-01

    Biological oxygen demand (BOD5) or chemical oxygen demand (COD) analysis is widely used to evaluate organic pollutants in water systems as well as the efficiency of wastewater treatment plants. However, both analysis methods have restrictions such as being insensitive, imprecise, time-consuming, and the production of chemical waste. Therefore, total organic carbon (TOC) analysis for organic pollutants has been considered for an alternative analysis instead of BOD5 or COD. Several studies have investigated the replacement of BOD5 or COD with TOC in wastewater samples; however, few studies have investigated the relationships between water quality parameters in rivers and lakes. Therefore, this study evaluated the relationships between BOD5, COD, or NBOPs and TOC by the analysis of national water quality monitoring data of rivers and lakes for 5 years. High correlation coefficients (r) of 0.87 and 0.66 between BOD5 and TOC (p TOC (p TOC was 0.93 for rivers and 0.72 for lakes. The coefficients of determination (R 2) were 0.75 and 0.44 between BOD5 and TOC for rivers and lakes as well as were 0.87 and 0.57 between COD and TOC for rivers and lakes, respectively. The coefficient of determination (R 2) between NBOPs and TOC was 0.73 for rivers and 0.52 for lakes.

  14. Anaerobic on-site treatment of black water and dairy parlour wastewater in UASB-septic tanks at low temperatures.

    Science.gov (United States)

    Luostarinen, Sari A; Rintala, Jukka A

    2005-01-01

    Anaerobic on-site treatment of synthetic black water (BW) and dairy parlour wastewater (DPWW) was studied in two-phased upflow anaerobic sludge blanket (UASB)-septic tanks at low temperatures (10-20 degrees C). At all temperatures, total chemical oxygen demand (COD(t)) removal was above 90% with BW and above 80% with DPWW and removal of total suspended solids (TSS) above 90% with both wastewaters. Moreover, dissolved COD (COD(dis)) removal was approx. 70% with both wastewaters indicating good biological activity of the sludges. With BW, a single-phased reactor was found sufficient for good COD removals, while with DPWW, a two-phased process was required. Temperature optimum of reactor sludges was still 35 degrees C after long (398d) operation. Most of the nutrients from BW were removed with TSS, while with DPWW nutrient removal was low. In conclusion, UASB-septic tank was found feasible for (pre)treatment of BW and DPWW at low temperatures.

  15. Cod reproductive ecology

    DEFF Research Database (Denmark)

    Røjbek, Maria

    In recent decades, Baltic cod has experienced a period of low recruitment. In the same period the pelagic Baltic Sea ecosystem experienced a regime shift, due to hydrographic changes, affecting all trophic levels. The rationale for the thesis is built on the hypothesis that the regime shift has r...

  16. Soil aquifer treatment of artificial wastewater under saturated conditions

    KAUST Repository

    Essandoh, H. M K

    2011-05-01

    A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen and phosphate, using high strength artificial wastewater. The removal rates were determined under a combination of constant hydraulic loading rates (HLR) and variable COD concentrations as well as variable HLR under a constant COD. Within the range of COD concentrations considered (42 mg L-1-135 mg L-1) it was found that at fixed hydraulic loading rate, a decrease in the influent concentrations of dissolved organic carbon (DOC), biochemical oxygen demand (BOD), total nitrogen and phosphate improved their removal efficiencies. At the high COD concentrations applied residence times influenced the redox conditions in the soil column. Long residence times were detrimental to the removal process for COD, BOD and DOC as anoxic processes and sulphate reduction played an important role as electron acceptors. It was found that total COD mass loading within the range of 911 mg d-1-1780 mg d-1 applied as low COD wastewater infiltrated coupled with short residence times would provide better effluent quality than the same mass applied as a COD with higher concentration at long residence times. The opposite was true for organic nitrogen where relatively high concentrations coupled with long residence time gave better removal efficiency. © 2011.

  17. Removal of nitrogen from anaerobically digested swine wastewater ...

    African Journals Online (AJOL)

    This result indicates that the sulfur-packed biofilter would be used as an efficient option for denitrification by autotrophic denitrifiers during swine wastewater treatment. Key words: Biological nitrogen removal, nitrification, denitrification, chemical oxygen demand (COD), intermittent aeration, sulfur-packed bed reactor, swine ...

  18. Removal Efficiency of Electrocoagulation Treatment Using Aluminium Electrode for Stabilized Leachate

    Science.gov (United States)

    Mohamad Zailani, L. W.; Amdan, N. S. Mohd; Zin, N. S. M.

    2018-04-01

    This research was conducted to investigate the performance of aluminium electrode in electrocoagulation process removing chemical oxygen demand (COD), ammonia, turbidity, colour and suspended solid (SS) from Simpang Renggam landfill leachate. Effects of current density, electrolysis duration and pH were observed in this study. From the data obtained, optimum condition at current density was recorded at 200 A/m2with the electrolysis duration of 20-minutes and optimum pH value at 4. The removal recorded at this condition for COD, ammonia, colour, turbidity and suspended solid were 60%, 37%, 94%, 88% and 89% respectively. Electrocoagulation treatment give a better result and can be applied for leachate treatment in future. Thus, electrocoagulation treatment has the potential to be used in treatment of leachate.

  19. Kinetics of aerobically activated sludge on terylene artificial silk printing and dyeing wastewater treatment.

    Science.gov (United States)

    Guan, Bao-hong; Wu, Zhong-biao; Xu, Gen-liang

    2004-04-01

    Aerobically activated sludge processing was carried out to treat terylene artificial silk printing and dyeing wastewater (TPD wastewater) in a lab-scale experiment, focusing on the kinetics of the COD removal. The kinetics parameters determined from experiment were applied to evaluate the biological treatability of wastewater. Experiments showed that COD removal could be divided into two stages, in which the ratio BOD/COD (B/C) was the key factor for stage division. At the rapid-removal stage with B/C>0.1, COD removal could be described by a zero order reaction. At the moderate-removal stage with B/Ckinetic parameters, the biological treatability of TPD wastewater was superior to that of traditional textile wastewater. But COD removal from TPD-wastewater was much more difficult than that from domestic and industrial wastewater, such as papermaking, beer, phenol wastewater, etc. The expected effluent quality strongly related to un-biodegradable COD and kinetics rather than total COD. The results provide useful basis for further scaling up and efficient operation of TPD wastewater treatment.

  20. Rationale for restocking the Eastern Baltic cod stock

    DEFF Research Database (Denmark)

    Støttrup, Josianne; Overton, Julia Lynne; Paulsen, Helge

    2008-01-01

    The Danish Institute for Fisheries Research and Bornholm's Salmon Hatchery examined the potential for restocking Baltic cod (Gadus morhua callarias L.) in the eastern Baltic Sea. This cod population has adapted to the unique brackish water conditions where successful spawning depends on regular i...

  1. Coupling of anodic oxidation and adsorption by granular activated carbon for chemical oxygen demand removal from 4,4'-diaminostilbene-2,2'-disulfonic acid wastewater.

    Science.gov (United States)

    Wang, Lizhang; Zhao, Yuemin

    2010-01-01

    Experiments were performed to reduce chemical oxygen demand (COD) from 4,4'-diaminostilbene-2,2'-disulfonic (DSD) acid manufacturing wastewater using electrochemical oxidation coupled with adsorption by granular activated carbon. The COD removal is affected by the residence time and applied voltage. When the residence time is increased, lower value of COD effluent could be obtained, however, the average current efficiency (ACE) decreased rapidly, and so does the applied voltage. In addition, aeration could effectively enhance COD removal efficiency and protect anodes from corrosion. Furthermore, the acidic condition is beneficial to the rapid decrease of COD and the values of pH effluent are independent of the initial solution pH. The optimization conditions obtained from these experiments are applied voltage of 4.8 V, residence time of 180 min and air-liquid ratio of 4.2 with the COD effluent of about 690 mg L⁻¹. In these cases, the ACE and energy consumption are 388% and 4.144 kW h kg⁻¹ COD, respectively. These perfect results from the experiments illustrate that the combined process is a considerable alternative for the treatment of industrial wastewater containing high concentration of organic pollutants and salinity.

  2. Electrochemical oxidation of COD from real textile wastewaters: Kinetic study and energy consumption.

    Science.gov (United States)

    Zou, Jiaxiu; Peng, Xiaolan; Li, Miao; Xiong, Ying; Wang, Bing; Dong, Faqin; Wang, Bin

    2017-03-01

    In the present study, the electrochemical oxidation of real wastewaters discharged by textile industry was carried out using a boron-doped diamond (BDD) anode. The effect of operational variables, such as applied current density (20-100 mA·cm -2 ), NaCl concentration added to the real wastewaters (0-3 g·L -1 ), and pH value (2.0-10.0), on the kinetics of COD oxidation and on the energy consumption was carefully investigated. The obtained experimental results could be well matched with a proposed kinetic model, in which the indirect oxidation mediated by electrogenerated strong oxidants would be described through a pseudo-first-order kinetic constant k. Values of k exhibited a linear increase with increasing applied current density and decreasing pH value, and an exponential increase with NaCl concentration. Furthermore, high oxidation kinetics resulted in low specific energy consumption, but this conclusion was not suitable to the results obtained under different applied current density. Under the optimum operational conditions, it only took 3 h to complete remove the COD in the real textile wastewaters and the specific energy consumption could be as low as 11.12 kWh·kg -1  COD. The obtained results, low energy consumption and short electrolysis time, allowed to conclude that the electrochemical oxidation based on BDD anodes would have practical industrial application for the treatment of real textile wastewater. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Combined soil washing and CDEO for the removal of atrazine from soils

    Energy Technology Data Exchange (ETDEWEB)

    Vieira dos Santos, Elisama [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Sáez, Cristina [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain); Martínez-Huitle, Carlos Alberto [Institute of Chemistry, Federal University of Rio Grande do Norte, Lagoa Nova CEP 59078-970, Natal, RN (Brazil); Cañizares, Pablo; Rodrigo, Manuel Andres [Department of Chemical Engineering, Universidad de Castilla – La Mancha, Enrique Costa Building, Campus Universitario s/n, 13071 Ciudad Real (Spain)

    2015-12-30

    Highlights: • Sequential soil washing-waste electrolysis is an efficient treatment for removing atrazine. • Ratio surfactant/soil influences on the size of micelles and organic load. • Electrolysis with diamond anodes oxidizes pollutants from soils washing wastes. • Electrolysis of soil washing fluids promotes the reduction in size of micelles. • Sulphate ions release from the oxidation of SDS participates in the oxidation process. - Abstract: In this work, it is studied the removal of atrazine from spiked soils by soil washing using surfactant fluids, followed by the treatment of the resulting washing waste by electrolysis with boron doped diamond (BDD) anode. Results confirm that combination of both technologies is efficient for the removal and total mineralization of atrazine. Ratio surfactant/soil is a key parameter for the removal of atrazine from soil and influences significantly in the characteristic of the wastewater produced, affecting not only to the total organic load but also to the mean size of micelles. The higher the ratio surfactant soil, the lower is the size of the particles. Electrolyses of this type of waste attain the complete mineralization. TOC and COD are removed from the start of the treatment but the key of the treatment is the reduction in size of the micelles, which lead to a higher negative charge in the surface and to the faster depletion of the surfactant as compared with the pesticide.

  4. Spatio-temporal variability of the North Sea cod recruitment in relation to temperature and zooplankton.

    Directory of Open Access Journals (Sweden)

    Delphine Nicolas

    Full Text Available The North Sea cod (Gadus morhua, L. stock has continuously declined over the past four decades linked with overfishing and climate change. Changes in stock structure due to overfishing have made the stock largely dependent on its recruitment success, which greatly relies on environmental conditions. Here we focus on the spatio-temporal variability of cod recruitment in an effort to detect changes during the critical early life stages. Using International Bottom Trawl Survey (IBTS data from 1974 to 2011, a major spatio-temporal change in the distribution of cod recruits was identified in the late 1990s, characterized by a pronounced decrease in the central and southeastern North Sea stock. Other minor spatial changes were also recorded in the mid-1980s and early 1990s. We tested whether the observed changes in recruits distribution could be related with direct (i.e. temperature and/or indirect (i.e. changes in the quantity and quality of zooplankton prey effects of climate variability. The analyses were based on spatially-resolved time series, i.e. sea surface temperature (SST from the Hadley Center and zooplankton records from the Continuous Plankton Recorder Survey. We showed that spring SST increase was the main driver for the most recent decrease in cod recruitment. The late 1990s were also characterized by relatively low total zooplankton biomass, particularly of energy-rich zooplankton such as the copepod Calanus finmarchicus, which have further contributed to the decline of North Sea cod recruitment. Long-term spatially-resolved observations were used to produce regional distribution models that could further be used to predict the abundance of North Sea cod recruits based on temperature and zooplankton food availability.

  5. Grey water treatment in UASB reactor at ambient temperature.

    Science.gov (United States)

    Elmitwalli, T A; Shalabi, M; Wendland, C; Otterpohl, R

    2007-01-01

    In this paper, the feasibility of grey water treatment in a UASB reactor was investigated. The batch recirculation experiments showed that a maximum total-COD removal of 79% can be obtained in grey-water treatment in the UASB reactor. The continuous operational results of a UASB reactor treating grey water at different hydraulic retention time (HRT) of 20, 12 and 8 hours at ambient temperature (14-24 degrees C) showed that 31-41% of total COD was removed. These results were significantly higher than that achieved by a septic tank (11-14%), the most common system for grey water pre-treatment, at HRT of 2-3 days. The relatively lower removal of total COD in the UASB reactor was mainly due to a higher amount of colloidal COD in the grey water, as compared to that reported in domestic wastewater. The grey water had a limited amount of nitrogen, which was mainly in particulate form (80-90%). The UASB reactor removed 24-36% and 10-24% of total nitrogen and total phosphorus, respectively, in the grey water, due to particulate nutrients removal by physical entrapment and sedimentation. The sludge characteristics of the UASB reactor showed that the system had stable performance and the recommended HRT for the reactor is 12 hours.

  6. Timing of urinary catheter removal after uncomplicated total abdominal hysterectomy: a prospective randomized trial.

    Science.gov (United States)

    Ahmed, Magdy R; Sayed Ahmed, Waleed A; Atwa, Khaled A; Metwally, Lobna

    2014-05-01

    To assess whether immediate (0h), intermediate (after 6h) or delayed (after 24h) removal of an indwelling urinary catheter after uncomplicated abdominal hysterectomy can affect the rate of re-catheterization due to urinary retention, rate of urinary tract infection, ambulation time and length of hospital stay. Prospective randomized controlled trial conducted at Suez Canal University Hospital, Egypt. Two hundred and twenty-one women underwent total abdominal hysterectomy for benign gynecological diseases and were randomly allocated into three groups. Women in group A (73 patients) had their urinary catheter removed immediately after surgery. Group B (81 patients) had the catheter removed 6h post-operatively while in group C (67 patients) the catheter was removed after 24h. The main outcome measures were the frequency of urinary retention, urinary tract infections, ambulation time and length of hospital stay. There was a significantly higher number of urinary retention episodes requiring re-catheterization in the immediate removal group compared to the intermediate and delayed removal groups (16.4% versus 2.5% and 0% respectively). Delayed urinary catheter removal was associated with a higher incidence of urinary tract infections (15%), delayed ambulation time (10.3h) and longer hospital stay (5.6 days) compared to the early (1.4%, 4.1h and 3.2 days respectively) and intermediate (3.7%, 6.8h and 3.4 days respectively) removal groups. Removal of the urinary catheter 6h postoperatively appears to be more advantageous than early or late removal in cases of uncomplicated total abdominal hysterectomy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Salt removal using multiple microbial desalination cells under continuous flow conditions

    KAUST Repository

    Qu, Youpeng

    2013-05-01

    Four microbial desalination cells (MDCs) were hydraulically connected and operated under continuous flow conditions. The anode solution from the first MDC flowed into the cathode, and then on to the anode of the next reactor, which avoided pH imbalances that inhibit bacterial metabolism. The salt solution also moved through each desalination chamber in series. Increasing the hydraulic retention times (HRTs) of the salt solution from 1 to 2. days increased total NaCl removal from 76 ± 1% to 97 ± 1%, but coulombic efficiencies decreased from 49 ± 4% to 35 ± 1%. Total COD removals were similar at both HRTs (60 ± 2%, 2. days; 59 ± 2%, 1. day). Community analysis of the anode biofilms showed that bacteria most similar to the xylose fermenting bacterium Klebsiella ornithinolytica predominated in the anode communities, and sequences most similar to Geobacter metallireducens were identified in all MDCs except the first one. These results demonstrated successful operation of a series of hydraulically connected MDCs and good desalination rates. © 2013 Elsevier B.V..

  8. Effect of temperature on selenium removal from wastewater by UASB reactors.

    Science.gov (United States)

    Dessì, Paolo; Jain, Rohan; Singh, Satyendra; Seder-Colomina, Marina; van Hullebusch, Eric D; Rene, Eldon R; Ahammad, Shaikh Ziauddin; Carucci, Alessandra; Lens, Piet N L

    2016-05-01

    The effect of temperature on selenium (Se) removal by upflow anaerobic sludge blanket (UASB) reactors treating selenate and nitrate containing wastewater was investigated by comparing the performance of a thermophilic (55 °C) versus a mesophilic (30 °C) UASB reactor. When only selenate (50 μM) was fed to the UASB reactors (pH 7.3; hydraulic retention time 8 h) with excess electron donor (lactate at 1.38 mM corresponding to an organic loading rate of 0.5 g COD L(-1) d(-1)), the thermophilic UASB reactor achieved a higher total Se removal efficiency (94.4 ± 2.4%) than the mesophilic UASB reactor (82.0 ± 3.8%). When 5000 μM nitrate was further added to the influent, total Se removal was again better under thermophilic (70.1 ± 6.6%) when compared to mesophilic (43.6 ± 8.8%) conditions. The higher total effluent Se concentration in the mesophilic UASB reactor was due to the higher concentrations of biogenic elemental Se nanoparticles (BioSeNPs). The shape of the BioSeNPs observed in both UASB reactors was different: nanospheres and nanorods, respectively, in the mesophilic and thermophilic UASB reactors. Microbial community analysis showed the presence of selenate respirers as well as denitrifying microorganisms. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Comparison of COD, R6, and J-contour integral methods of defect assessment, modified to give critical flaw sizes

    International Nuclear Information System (INIS)

    Burdekin, F.M.; Turner, C.E.

    1982-01-01

    A comparative study of the application of different elastic-plastic fracture mechanics methods to the calculation of critical defect sizes in pressure vessels showed widely varying results. The present authors have investigated in detail the reasons for the variations resulting from the use of the CEGB R6, COD design curve, and J-design curve methods to the particular pressure vessel problems. To obtain reasonable agreement between the three methods for the calculation of critical flaw sizes in high stress gradient situations, the published COD method in PD6493 has to be modified to remove its inherent safety factor, and to allow for stress gradients, and a consistent treatment for gross yielding/collapse has to be adopted for all three methods. (author)

  10. Nitrogen and chemical oxygen demand removal from septic tank wastewater in subsurface flow constructed wetlands: substrate (cation exchange capacity) effects.

    Science.gov (United States)

    Collison, Robert S; Grismer, Mark E

    2014-04-01

    The current article focuses on chemical oxygen demand (COD) and nitrogen (ammonium and nitrate) removal performance from synthetic human wastewater as affected by different substrate rocks having a range of porosities and cation exchange capacities (CECs). The aggregates included lava rock, lightweight expanded shale, meta-basalt (control), and zeolite. The first three had CECs of 1 to 4 mequiv/100 gm, whereas the zeolite CEC was much greater (-80 mequiv/100 gm). Synthetic wastewater was gravity fed to each constructed wetland system, resulting in a 4-day retention time. Effluent samples were collected, and COD and nitrogen species concentrations measured regularly during four time periods from November 2008 through June 2009. Chemical oxygen demand and nitrogen removal fractions were not significantly different between the field and laboratory constructed wetland systems when corrected for temperature. Similarly, overall COD and nitrogen removal fractions were practically the same for the aggregate substrates. The important difference between aggregate effects was the zeolite's ammonia removal process, which was primarily by adsorption. The resulting single-stage nitrogen removal process may be an alternative to nitrification and denitrification that may realize significant cost savings in practice.

  11. Quantifying predation on Baltic cod early life stages

    DEFF Research Database (Denmark)

    Neumann, Viola; Schaber, Matthias; Eero, Margit

    2017-01-01

    Predation on cod (Gadus morhua) eggs by sprat (Sprattus sprattus) and herring (Clupea harengus) is known to be one of the processes influencing reproductive success of the eastern Baltic cod and has been reported to have contributed to lack of recovery of the stock in the 1990s. This study quanti...

  12. The influence of ozonated time on the degree of depreciation of BOD, COD, TSS and phosphate in hospital liquid waste

    International Nuclear Information System (INIS)

    Isyuniarto and Andrianto

    2009-01-01

    The influence of ozonated time towards degree depreciation of Bode, COD, TSS and phosphate in hospital liquid waste was done. This research aim study influence of lime adding and ozone using to reduce of BOD, COD, TSS and phosphate in hospital waste. Added of lime mean for total increase ion OH - , while parameter of ozonization time mean to complete organic compounds oxidation in waste and flock formation. From this research it was found that optimum lime addition was 1.1% (% weight) and ozonization time was 20 minutes. In this condition it was achieved degree of BOD = 18.88 mg/l; COD = 25.68 mg/l, TSS = 80 mg/l and phosphate = 1.52 mg/l. This condition fulfil quality standard decided, that has to BOD = 75 mg/l; COD = 100 mg/l, TSS = 100 mg/l and phosphate = 2.0 mg/l. (author)

  13. Comparison of Poly Aluminum Chloride and Chlorinated Cuprous for Chemical Oxygen Demand and Color Removal from Kashan Textile Industries Company Wastewater

    Directory of Open Access Journals (Sweden)

    Hoseindoost Gh.1 MSPH,

    2016-08-01

    Full Text Available Aims Textile wastewaters are the most important health and environmental problems in Kashan. This research was aimed to compare the poly aluminum chloride and chlorinated cuprous efficiency for removal of Chemical Oxygen Demand (COD and color from Kashan Textile Industries Company wastewater. Materials & Methods This experimental bench scale study in a batch system was conducted on 20 composed wastewater samples collected from Kashan Textile Industries Company raw wastewater. During 5 months, in the beginning of every week a day was selected randomly and in the day a composed sample was taken and studied. PAC at the doses of 10, 20, 30, 40 and 50mg.l-1 and chlorinated cuprous at the doses of 100, 200, 300, 400 and 500mg.l-1 were applied. The optimum pH also optimum concentration of PAC and chlorinated cuprous were determined using Jar test. The data was analyzed by SPSS 16 using descriptive statistics and Fisher Exact test. Findings The average concentration of COD in the raw textile wastewater was 2801.56±1398.29mg.l-1. The average COD concentration has been decreased to 1125.47±797.55mg.l-1. There was a significant difference between the effects of these two coagulants efficiency (p<0.05. The average COD removal efficiency for chlorinated cuprous and PAC was 58.52% and 72.56%, respectively. Also, the average color removal efficiency by chlorinated cuprous and PAC were 17.23 and 64.45%, respectively. Conclusion PAC is more efficient than chlorinated cuprous for both COD and color removal from KTIC wastewater.

  14. CodY Regulates Thiol Peroxidase Expression as Part of the Pneumococcal Defense Mechanism against H2O2 Stress.

    Science.gov (United States)

    Hajaj, Barak; Yesilkaya, Hasan; Shafeeq, Sulman; Zhi, Xiangyun; Benisty, Rachel; Tchalah, Shiran; Kuipers, Oscar P; Porat, Nurith

    2017-01-01

    Streptococcus pneumoniae is a facultative anaerobic pathogen. Although it maintains fermentative metabolism, during aerobic growth pneumococci produce high levels of H 2 O 2 , which can have adverse effects on cell viability and DNA, and influence pneumococcal interaction with its host. The pneumococcus is unusual in its dealing with toxic reactive oxygen species (ROS) in that it neither has catalase nor the global regulators of peroxide stress resistance. Previously, we identified pneumococcal thiol peroxidase (TpxD) as the key enzyme for enzymatic removal of H 2 O 2 , and showed that TpxD synthesis is up-regulated upon exposure to H 2 O 2 . This study aimed to reveal the mechanism controlling TpxD expression under H 2 O 2 stress. We hypothesize that H 2 O 2 activates a transcription factor which in turn up-regulates tpxD expression. Microarray analysis revealed a pneumococcal global transcriptional response to H 2 O 2 . Mutation of tpxD abolished H 2 O 2 -mediated response to high H 2 O 2 levels, signifying the need for an active TpxD under oxidative stress conditions. Bioinformatic tools, applied to search for a transcription factor modulating tpxD expression, pointed toward CodY as a potential candidate. Indeed, a putative 15-bp consensus CodY binding site was found in the proximal region of tpxD- coding sequence. Binding of CodY to this site was confirmed by EMSA, and genetic engineering techniques demonstrated that this site is essential for TpxD up-regulation under H 2 O 2 stress. Furthermore, tpxD expression was reduced in a Δ codY mutant. These data indicate that CodY is an activator of tpxD expression, triggering its up-regulation under H 2 O 2 stress. In addition we show that H 2 O 2 specifically oxidizes the 2 CodY cysteines. This oxidation may trigger a conformational change in CodY, resulting in enhanced binding to DNA. A schematic model illustrating the contribution of TpxD and CodY to pneumococcal global transcriptional response to H 2 O 2 is

  15. Removal of organic substances and oxidation of ammonium nitrogen by a down-flow hanging sponge (DHS) reactor under high salinity conditions.

    Science.gov (United States)

    Uemura, Shigeki; Suzuki, Saori; Abe, Kenichi; Kubota, Keiichi; Yamaguchi, Takashi; Ohashi, Akiyoshi; Takemura, Yasuyuki; Harada, Hideki

    2010-07-01

    A down-flow hanging sponge (DHS) reactor, constructed by connecting three identical treatment units in series, was fed with highly saline artificial coke-plant wastewater containing 1400 mg L(-1) of phenol in terms of chemical oxygen demand (COD) and 500 mg-NL(-1) of ammonium nitrogen. The COD was removed by the 1st unit, achieving 92% removal at an average COD loading rate of 3.0 kg-COD m(-3)d(-1) for all units, with oxidation of ammonium nitrogen occurring primarily in the two downstream units. Microbial assays of the different units of the reactor revealed greater numbers of nitrifying bacteria in the 2nd and 3rd units than in the 1st unit, corresponding with the observed ammonium oxidation pattern of the reactor. These findings suggest that a succession of microflora was successfully established along the DHS. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  16. Tuning the pH-shift protein-isolation method for maximum hemoglobin-removal from blood rich fish muscle.

    Science.gov (United States)

    Abdollahi, Mehdi; Marmon, Sofia; Chaijan, Manat; Undeland, Ingrid

    2016-12-01

    A main challenge preventing optimal use of protein isolated from unconventional raw materials (e.g., small pelagic fish and fish by-products) using the pH-shift method is the difficulty to remove enough heme-pigments. Here, the distribution of hemoglobin (Hb) in the different fractions formed during pH-shift processing was studied using Hb-fortified cod mince. Process modifications, additives and prewashing were then investigated to further facilitate Hb-removal. The alkaline pH-shift process version could remove considerably more Hb (77%) compared to the acidic version (37%) when proteins were precipitated at pH 5.5; most Hb was removed during dewatering. Protein precipitation at pH 6.5 improved total Hb removal up to 91% and 74% during alkaline and acid processing, respectively. Adding phytic acid to the first supernatant of the alkaline process version yielded 93% Hb removal. Combining one prewash with phytic acid at pH 5.5 followed by alkaline/acid pH-shift processing increased Hb removal up to 96/92%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Dynamic modeling of nutrient removal by a MBR operated at elevated temperatures.

    Science.gov (United States)

    Sarioglu, M; Sayi-Ucar, N; Cokgor, E; Orhon, D; van Loosdrecht, M C M; Insel, G

    2017-10-15

    The process performance of a MBR operated on municipal sewage at elevated temperatures was evaluated by dynamic modeling. The enhanced biological phosphorus removal (EBPR) performance varied from 40% to 95% with process temperature ranging from 24 to 38 °C. The respective maximum substrate uptake rate (q PHA ) was estimated at 1.5 gCOD S /gCOD X .day -1 for Glycogen Accumulating Organisms (GAO) and 4.7 gCOD S /gCOD X .day -1 for Phosphate Accumulating Organisms (PAO) with Arrhenius coefficients (θ) for GAOs and PAOs of 1.06 and 1.04 respectively. With these parameters the effluent PO 4 levels of the MBR operated for 450 days could be well described. In addition, the impact of mesophilic conditions and low influent P/VFA levels on GAO proliferation was evaluated under dynamic process conditions. Nitrification process was temporarily impaired at high temperatures around 38 °C. Simulations revealed that the contribution of the anoxic reactor to the total overall denitrification was limited to 40%The contribution of simultaneous nitrification and denitrification (SNdN) process to the denitrification was around 40-50% depending upon dissolved oxygen levels in aerobic and MBR tanks. The large contribution of SNdN was due to gas/liquid mass transfer limitation conditions mediated by high mixed liquor viscosities (20-35 mPa.S) in MBR system. The membrane flux was 43 L/m 2 /h corresponding to the specific permeability (K) of 413 L/m 2 /h/bar at 38 °C. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Isolation of an indigenous Chlorella vulgaris from swine wastewater and characterization of its nutrient removal ability in undiluted sewage.

    Science.gov (United States)

    Wen, Yangmin; He, Yongjin; Ji, Xiaowei; Li, Shaofeng; Chen, Ling; Zhou, Youcai; Wang, Mingzi; Chen, Bilian

    2017-11-01

    Bio-treatment of wastewater mediated by microalgae is considered as a promising solution. This work aimed to isolate an indigenous microalgal strain (named MBFJNU-1) from swine wastewater effluent and identify as Chlorella vulgaris. After 12days, the removal efficiencies of total nitrogen (TN) and total phosphorus (TP) in undiluted swine slurry were 90.51% and 91.54%, respectively. Stress tolerance in response to wastewater was verified by cultivating in artificial wastewater containing different levels of chemical oxygen demand (COD), TN and TP. MBFJNU-1 could grow well in undiluted swine slurry and artificial wastewater containing 30,000mg/L COD or 2000mg/L TN. Furthermore, global nuclear DNA methylation (5-mC) of MBFJNU-1 was employed to explore the possible mechanism in response to wastewater stress. The results showed that the level of 5-mC was inversely proportional to the growth of MBFJNU-1 in different diluted swine slurry, helping to understand 5-mC variation in response to stress environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Northeast Regional Cod Tagging Program

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Scientific justification: Canadian and US stock assessments for Atlantic cod indicate considerable fluctuation in stock abundance and recruitment over the last 20...

  20. The effect of amino acids on lipid production and nutrient removal by Rhodotorula glutinis cultivation in starch wastewater.

    Science.gov (United States)

    Liu, Meng; Zhang, Xu; Tan, Tianwei

    2016-10-01

    In this paper, the components of amino acids in mixed starch wastewater (corn steep water/corn gluten water=1/3, v/v) were analyzed by GC-MS. Effects of amino acids on lipid production by Rhodotorula glutinis and COD removal were studied. The results showed that mixed starch wastewater contained 9 kinds of amino acids and these amino acids significantly improved the biomass (13.63g/L), lipid yield (2.48g/L) and COD removal compared to the basic medium (6.23g/L and 1.56g/L). In a 5L fermentor containing mixed starch wastewater as substrate to culture R. glutinis, the maximum biomass, lipid content and lipid yield reached 26.38g/L, 28.90% and 7.62g/L, with the associated removal rates of COD, TN and TP reaching 77.41%, 69.12% and 73.85%, respectively. The results revealed a promising approach for lipid production with using amino acids present in starch wastewater as an alternative nitrogen source. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Simulation-based investigation of the paired-gear method in cod-end selectivity studies

    DEFF Research Database (Denmark)

    Herrmann, Bent; Frandsen, Rikke; Holst, René

    2007-01-01

    In this paper, the paired-gear and covered cod-end methods for estimating the selectivity of trawl cod-ends are compared. A modified version of the cod-end selectivity simulator PRESEMO is used to simulate the data that would be collected from a paired-gear experiment where the test cod-end also ...

  2. Combined organic matter and nitrogen removal from a chemical industry wastewater in a two-stage MBBR system.

    Science.gov (United States)

    Cao, S M S; Fontoura, G A T; Dezotti, M; Bassin, J P

    2016-01-01

    Pesticide-producing factories generate highly polluting wastewaters containing toxic and hazardous compounds which should be reduced to acceptable levels before discharge. In this study, a chemical industry wastewater was treated in a pre-denitrification moving-bed biofilm reactor system subjected to an increasing internal mixed liquor recycle ratio from 2 to 4. Although the influent wastewater characteristics substantially varied over time, the removal of chemical oxygen demand (COD) and dissolved organic carbon was quite stable and mostly higher than 90%. The highest fraction of the incoming organic matter was removed anoxically, favouring a low COD/N environment in the subsequent aerobic nitrifying tank and thus ensuring stable ammonium removal (90-95%). However, during pH and salt shock periods, nitrifiers were severely inhibited but gradually restored their full nitrifying capability as non-stressing conditions were reestablished. Besides promoting an increase in the maximum nitrification potential of the aerobic attached biomass from 0.34 to 0.63 mg [Formula: see text], the increase in the internal recycle ratio was accompanied by an increase in nitrogen removal (60-78%) and maximum specific denitrification rate (2.7-3.3 mg NOx(-)--N). Total polysaccharides (PS) and protein (PT) concentrations of attached biomass were observed to be directly influenced by the influent organic loading rate, while the PS/PT ratio mainly ranged from 0.3 to 0.5. Results of Microtox tests showed that no toxicity was found in the effluent of both the anoxic and aerobic reactors, indicating that the biological process was effective in removing residual substances which might adversely affect the receiving waters' ecosystem.

  3. Removal of pollutants from pulp and paper mill effluent by anaerobic and aerobic treatment in pilot scale bioreactor

    DEFF Research Database (Denmark)

    Singh, P.; Katiyar, D.; Gupta, M.

    2011-01-01

    Pilot-scale anaerobic and aerobic treatment in a two-step bioreactor was performed for the removal of pollutants from pulp and paper mill effluent. After seven days of anaerobic treatment, colour (45%), lignin (60%), COD (26%) and adsorbable organic halogen (AOX) (20%) were reduced. The anaerobic......Pilot-scale anaerobic and aerobic treatment in a two-step bioreactor was performed for the removal of pollutants from pulp and paper mill effluent. After seven days of anaerobic treatment, colour (45%), lignin (60%), COD (26%) and adsorbable organic halogen (AOX) (20%) were reduced....... The anaerobically treated effluent was then treated in a bioreactor in the presence of a fungal strain (Aspergillus fumigatus) or a bacterial strain (Pseudomonas ovalis). The results of this study indicated a reduction in colour (76% and 56%), lignin (78% and 68%), COD (85% and 78%) and AOX (70% and 82...

  4. Evaluation of Organic Matter Removal Efficiency and Microbial Enzyme Activity in Vertical-Flow Constructed Wetland Systems

    Directory of Open Access Journals (Sweden)

    Qiaoling Xu

    2016-09-01

    Full Text Available In this study, enzyme activities and their relationships to organics purification were investigated in three different vertical flow constructed wetlands, namely system A (planting Pennisetum sinese Roxb, system B (planting Pennisetum purpureum Schum., and system C (no plant. These three wetland systems were fed with simulation domestic sewage at an influent flow rate of 20 cm/day. The results showed that the final removal efficiency of Chemical Oxygen Demand (COD in these three systems was 87%, 85% and 63%, respectively. Planting Pennisetum sinese Roxb and Pennisetum purpureum Schum. could improve the amount of adsorption and interception for organic matter in the substrate, and the amount of interception of organic matter in planting the Pennisetum sinese Roxb system was higher than that in planting the Pennisetum purpureum Schum. system. The activities of enzymes (urease, phosphatase and cellulase in systems A and B were higher than those in system C, and these enzyme activities in the top layer (0–30 cm were significantly higher than in the other layers. The correlations between the activities of urease, phosphatase, cellulase and the COD removal rates were R = 0.815, 0.961 and 0.973, respectively. It suggests that using Pennisetum sinese Roxb and Pennisetum purpureum Schum. as wetland plants could promote organics removal, and the activities of urease, phosphatase and cellulase in those three systems were important indicators for COD purification from wastewater. In addition, 0–30 cm was the main function layer. This study could provide a theoretical basis for COD removal in the wetland system and supply new plant materials for selection.

  5. Thermal niche of Atlantic cod Gadus morhua: limits, tolerance and optima

    DEFF Research Database (Denmark)

    Righton, David A.; Andersen, Ken Haste; Neat, Francis

    2010-01-01

    Recent studies in the marine environment have suggested that the limited phenotypic plasticity of cold-adapted species such as Atlantic cod Gadus morhua L. will cause distributions to shift toward the poles in response to rising sea temperatures. Some cod stocks are predicted to collapse, but thi......Recent studies in the marine environment have suggested that the limited phenotypic plasticity of cold-adapted species such as Atlantic cod Gadus morhua L. will cause distributions to shift toward the poles in response to rising sea temperatures. Some cod stocks are predicted to collapse...... niche of approximately 12°C, but latitudinal differences in water temperature meant that cod in the warmer, southern regions experienced 3 times the degree days (DD; ~4000 DD yr–1) than individuals from northern regions (~1200 DD yr–1). Growth rates increased with temperature, reaching a maximum...

  6. Pecan shell-based granular activated carbon for treatment of chemical oxygen demand (COD) in municipal wastewater.

    Science.gov (United States)

    Bansode, R R; Losso, J N; Marshall, W E; Rao, R M; Portier, R J

    2004-09-01

    The present investigation was undertaken to compare the adsorption efficiency of pecan shell-based granular activated carbon with the adsorption efficiency of the commercial carbon Filtrasorb 200 with respect to uptake of the organic components responsible for the chemical oxygen demand (COD) of municipal wastewater. Adsorption efficiencies for these two sets of carbons (experimental and commercial) were analyzed by the Freundlich adsorption model. The results indicate that steam-activated and acid-activated pecan shell-based carbons had higher adsorption for organic matter measured as COD, than carbon dioxide-activated pecan shell-based carbon or Filtrasorb 200 at all the carbon dosages used during the experiment. The higher adsorption may be related to surface area as the two carbons with the highest surface area also had the highest organic matter adsorption. These results show that granular activated carbons made from agricultural waste (pecan shells) can be used with greater effectiveness for organic matter removal from municipal wastewater than a coal-based commercial carbon. Copyright 2004 Elsevier Ltd.

  7. Decentralised treatment of concentrated sewage at low temperature in a two-step anaerobic system: two upflow-hybrid septic tanks.

    Science.gov (United States)

    Elmitwalli, T A; Sayed, S; Groendijk, L; van Lier, J; Zeeman, G; Lettinga, G

    2003-01-01

    The decentralised treatment of concentrated sewage (about 3,600 mgCOD/l) at low temperature was investigated in a two-step anaerobic system: two-anaerobic hybrid (AH) septic tanks (each 0.575 m3). The two reactors were placed in a temperature controlled-room and the HRT was 2.5 days for each reactor. The system was fed with concentrated domestic sewage, mainly black water from about 40 toilets flushed with only 4 litre of water and a limited amount of grey water. The system showed high removal efficiency for the different COD fractions. Mean removal efficiencies in the two-step AH-septic tank at 5 days HRT and 13 degrees C were 94, 98, 74 and 78% for total COD, suspended COD, colloidal COD and dissolved COD respectively. The results of short run experiments indicated that the presence of reticulated polyurethane foam (RPF) media in the AH-septic tank improved the removal of suspended COD by 22%. The first AH-septic tank was full of sludge after 4 months of operation due to the high removal of particulate COD and the limited hydrolysis at low temperature conditions. Therefore, a simple mathematical model was developed based on ADM1 (the IWA model in 2002). Based on the experimental results and the mathematical model, only a one-step AH septic tank is required. An HRT of 5.5-7.5 days is needed for that one-step AH septic tank to treat concentrated sewage at a low temperature of 13 degrees C. Such a system can provide a total COD removal as high as 87% and will be full of sludge after a period of more than a year.

  8. Diet of Norwegian coastal cod (Gadus morhua) studied by using citizen science

    Science.gov (United States)

    Enoksen, Siri Elise; Reiss, Henning

    2018-04-01

    The Norwegian coastal cod (Gadus morhua) is a keystone species in the food web of northern Norwegian fjords. Their relatively stationary populations might specifically depend on local food resources, but the diet of cod has rarely been studied in fjord systems. Using a citizen science approach, where recreational anglers and tourists participated in the sampling, we studied small-scale differences in the diet composition of cod in a fjord system in northern Norway. We compared the cod diet from the MPA Saltstraumen, characterised by strong tidal currents and a highly diverse and abundant fauna, with the inner fjord area of Skjerstadfjord. The diet composition of cod significantly differed between both areas within the fjord. Although fish was the dominant prey in both areas, cod consumed > 40% invertebrates in terms of weight, even in the cod size class of 70-99 cm. The invertebrate prey also caused the observed spatial differences. In Saltstraumen, brittle stars (Ophiuroidea), crabs (Brachyura) and sea cucumbers (Holothuroidea) were important food sources for cod, while sea urchins (Echinoidea), clams (Bivalvia), shrimps (Caridea) and krill (Euphausiacea) dominated the diet in the inner Skjerstadfjord. The high densities of sessile fauna in the dynamic environment of Saltstraumen, was only partly reflected in the diet of cod, with only Holothuroidea found in 17% of the stomachs. High rates of empty stomachs (24%), cannibalism as well as a higher proportion of low-energy prey in the diet of large cod, may indicate a shortage of high quality food in Skjerstadfjord. The samples for this study were collected through a citizen science campaign. This approach might provide opportunities to be used for coastal ecological monitoring with potential applications in local ecosystem management strategies through public involvement.

  9. Bay-scale population structure in coastal Atlantic cod in Labrador and Newfoundland, Canada

    DEFF Research Database (Denmark)

    Ruzzante, D.E.; Wroblewski, J.S.; Taggart, C.T.

    2000-01-01

    Polymorphisms at five microsatellite DNA loci provide evidence that Atlantic cod Gadus morhua inhabiting Gilbert Bay, Labrador are genetically distinguishable from offshore cod on the north- east Newfoundland shelf and from inshore cod in Trinity Bay, Newfoundland. Antifreeze activity in the blood...... of population structure suggest that important barriers to gene flow exist among five components that include two inshore (Gilbert and Trinity Bay) and three offshore cod aggregations on the north-east Newfoundland Shelf and the Grand Bank. D-A and D-SW estimates of genetic distance that involve Gilbert Bay cod...

  10. pH-adjustment strategy for volatile fatty acid production from high-strength wastewater for biological nutrient removal.

    Science.gov (United States)

    Xie, Li; Liu, Hui; Chen, Yin-Guang; Zhou, Qi

    2014-01-01

    Volatile fatty acid (VFA) production from three types of high-strength organic wastewater (cassava thin stillage, starch wastewater and yellow-wine processing wastewater) were compared. The results showed that cassava thin stillage was the most suitable substrate, based on its high specific VFA production (0.68 g chemical oxygen demand (COD)/g initial soluble chemical oxygen demand (SCOD)) and yield (0.72 g COD/g SCOD) as well as low nutrient content in the substrate and fermented liquid. The acid fermented cassava thin stillage was evaluated and compared with sodium acetate in a sequencing batch reactor system. Total nitrogen removal efficiency was higher with fermented cassava thin stillage than with the sodium acetate. The effects of pH and a pH-adjustment strategy on VFA production and composition were determined using cassava thin stillage. At an initial pH range of 7-11, a relatively high VFA concentration of about 9 g COD/L was obtained. The specific VFA production (g COD/g initial SCOD) increased from 0.27 to 0.47 to 0.67 at pH 8 and from 0.26 to 0.68 to 0.81 at pH 9 (initial pH, interval pH, and constant pH adjustment, respectively). The dominant VFA species changed significantly with the increasing frequency of the pH adjustment. Further studies will examine the metabolic pathways responsible for VFA composition.

  11. Industry Based Survey (IBS) Cod

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The "Gulf of Maine Atlantic Cod Industry-Based Survey" was a collaboration of the Massachusetts Division of Marine Fisheries and the fishing industry, with support...

  12. Northeast arctic cod stock and fishery dynamics

    Directory of Open Access Journals (Sweden)

    Oleg Bulatov

    2015-12-01

    Full Text Available Northeast arctic cod stock is one of a most valuable target of fisheries in the Barents Sea. The catches of cod for the period 1960-2014 are widely changed. The minimum level of catches is marked in 1990 (212 thousands ton, and the maximum values of catches were observed in 1969 – 1.2 mill. ton. In the recent years international catch of cod exceeded 1 mill. ton. Fishable and spawning stock biomass (SSB also widely changed in this period. According to ICES data, SSB had a minimum in 1965 (102 thousand tons, and extremely high level in 2013 – 2 150 thousand tons. Fishable biomass changed also widely. The maximum level is registered in 2013 – 3 636 thousand tons, and minimum value was 5 times less, 739 thousand tons (1983. The ratio between historical high level of SSB and catch in 2013 was 2.2:1.0, due to low value of fishing mortality. Possibility to increase catch will be discussed.

  13. Structure of chymotrypsin variant B from Atlantic cod, Gadus morhua

    DEFF Research Database (Denmark)

    Leth-Larsen, Rikke; Asgeirsson, B; Thórólfsson, M

    1996-01-01

    The amino-acid sequence of chymotrypsin variant B isolated from the pyloric caeca of Atlantic cod has been elucidated. The characterization of the primary structure is based on N-terminal Edman degradation and mass spectrometry of the native protein and enzymatically derived peptides. Chymotrypsi...... autolysis sites, cod variant B only contains a single autolysis site. The three-dimensional structures of the A- and B-variants of cod has been modelled on the known crystal structure of bovine alpha-chymotrypsin showing almost superimposable structures....

  14. "XANSONS for COD": a new small BOINC project in crystallography

    Science.gov (United States)

    Neverov, Vladislav S.; Khrapov, Nikolay P.

    2018-04-01

    "XANSONS for COD" (http://xansons4cod.com) is a new BOINC project aimed at creating the open-access database of simulated x-ray and neutron powder diffraction patterns for nanocrystalline phase of materials from the collection of the Crystallography Open Database (COD). The project uses original open-source software XaNSoNS to simulate diffraction patterns on CPU and GPU. This paper describes the scientific problem this project solves, the project's internal structure, its operation principles and organization of the final database.

  15. Aerobic granules formation and nutrients removal characteristics in sequencing batch airlift reactor (SBAR) at low temperature

    International Nuclear Information System (INIS)

    Bao Ruiling; Yu Shuili; Shi Wenxin; Zhang Xuedong; Wang Yulan

    2009-01-01

    To understand the effect of low temperature on the formation of aerobic granules and their nutrient removal characteristics, an aerobic granular sequencing batch airlift reactor (SBAR) has been operated at 10 deg. C using a mixed carbon source of glucose and sodium acetate. The results showed that aerobic granules were obtained and that the reactor performed in stable manner under the applied conditions. The granules had a compact structure and a clear out-surface. The average parameters of the granules were: diameter 3.4 mm, wet density 1.036 g mL -1 , sludge volume index 37 mL g -1 , and settling velocity 18.6-65.1 cm min -1 . Nitrite accumulation was observed, with a nitrite accumulation rate (NO 2 - -N/NO x - -N) between 35% and 43% at the beginning of the start-up stage. During the stable stage, NO x was present at a level below the detection limit. However, when the influent COD concentration was halved (resulting in COD/N a reduction of the COD/N from 20:1 to 10:1) nitrite accumulation was observed once more with an effluent nitrite accumulation rate of 94.8%. Phosphorus release was observed in the static feeding phase and also during the initial 20-30 min of the aerobic phase. Neither the low temperature nor adjustment of the COD/P ratio from 100:1 to 25:1 had any influence on the phosphorus removal efficiency under the operating conditions. In the granular reactor with the influent load rates for COD, NH 4 + -N, and PO 4 3- -P of 1.2-2.4, 0.112 and 0.012-0.024 kg m -3 d -1 , the respective removal efficiencies at low temperature were 90.6-95.4%, 72.8-82.1% and 95.8-97.9%.

  16. Simultaneous nitrogen and phosphorus removal in the sulfur cycle-associated Enhanced Biological Phosphorus Removal (EBPR) process.

    Science.gov (United States)

    Wu, Di; Ekama, George A; Wang, Hai-Guang; Wei, Li; Lu, Hui; Chui, Ho-Kwong; Liu, Wen-Tso; Brdjanovic, Damir; van Loosdrecht, Mark C M; Chen, Guang-Hao

    2014-02-01

    Hong Kong has practiced seawater toilet flushing since 1958, saving 750,000 m(3) of freshwater every day. A high sulfate-to-COD ratio (>1.25 mg SO4(2-)/mg COD) in the saline sewage resulting from this practice has enabled us to develop the Sulfate reduction, Autotrophic denitrification and Nitrification Integrated (SANI(®)) process with minimal sludge production and oxygen demand. Recently, the SANI(®) process has been expanded to include Enhanced Biological Phosphorus Removal (EBPR) in an alternating anaerobic/limited-oxygen (LOS-EBPR) aerobic sequencing batch reactor (SBR). This paper presents further development - an anaerobic/anoxic denitrifying sulfur cycle-associated EBPR, named as DS-EBPR, bioprocess in an alternating anaerobic/anoxic SBR for simultaneous removal of organics, nitrogen and phosphorus. The 211 day SBR operation confirmed the sulfur cycle-associated biological phosphorus uptake utilizing nitrate as electron acceptor. This new bioprocess cannot only reduce operation time but also enhance volumetric loading of SBR compared with the LOS-EBPR. The DS-EBPR process performed well at high temperatures of 30 °C and a high salinity of 20% seawater. A synergistic relationship may exist between sulfur cycle and biological phosphorus removal as the optimal ratio of P-release to SO4(2-)-reduction is close to 1.0 mg P/mg S. There were no conventional PAOs in the sludge. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Nutrients removal from artificial bathroom greywater using Botryococcus sp. strain

    Science.gov (United States)

    Mohamed, RMSR; Al-Gheethi, AA; Wurochekke, AA; Maizatul, AY; Matias-Peralta, HM; Kassim, AH Mohd

    2018-04-01

    The discharge of untreated bathroom greywater directly into drain is a most common practice in the rural area. The uncontrolled discharge of greywater from the village houses escalates the pollution among Malaysian river and provide insanitary environment through mosquito and flies breeding grounds. Therefore, the current work aimed to investigate the potential of Botryococcus sp. for removing total nitrogen (TN), total phosphorus (TP) and total organic carbon (TOC) from artificial bathroom greywater and to determine the bio-kinetic removal rate for these parameters. The artificial bathroom greywater was prepared by using regular brands used in the community, the bathroom greywater quality was tested for BOD, COD, SS, pH, and Turbidity. The removal process was conducted in the lab scale with 108 cell mL-1 of Botryococcus sp. The removal of TN, TP and TOC was measured in interval of 3, 5 and 7 days. The results deduced that Botryococcus sp. removed 51.5% of TN, 49.5% of TP and 42.6% of TOC. Moreover, the bio-kinetic model studies, revealed that the specific removal rate of TN, TP and TOC have a significant relationship with initial concentration in the artificial greywater (R2 = 0.63, 0.95 and 0.95 respectively). The kinetic coefficient of greywater parameters removed by Botryococcus sp. was determined as k=0.357 mg TN 1 log10 cell mL-1 d-1 and km=31.33 mg L-1 (R2=0.73), k=4.58 mg TP 1 log10 cell mL-1 d-1 and km=283.86 mg L-1 (R2=0.95), k=7.9 mg TOC 1 log10 cell mL-1 d-1 and km=322.32 mg L-1 (R2=0.97). The bio-kinetic model indicated that more than 90% of TN, TP and TOC was taken place as a response for Botryococcus sp.

  18. Improved management based on stock identification of eastern and western Baltic cod

    DEFF Research Database (Denmark)

    Hüssy, Karin; Bastardie, Francois; Eero, Margit

    The objective of this project was to establish an empirically founded knowledge base for the sustainable exploitation of the western Baltic cod stock by including the complex stock structure and migration patterns. Stock mapping: Extensive immigration of “Eastern” cod into the Arkona Basin (SD 24......) within the “Western” cod’s management unit was documented using high-powered genetic tools. The majority (91%) of all spawning fish caught in SD 24 in 2011 were “Eastern” cod and only 9% were from the “Western” stock. The results suggest that the stock structure in the Arkona Basin is highly influenced...... by mixing of genetically separate stocks. Trends in mixing: Since the 1980’s where cod in SD 24 consisted primarily of “Western” type, the proportion of “Eastern” cod has increased, particularly since 2005. Throughout that period, the immigration of “Eastern” cod into SD 24 consisted primarily of adult...

  19. A comparative study on the efficiency of ozonation and coagulation-flocculation as pretreatment to activated carbon adsorption of biologically stabilized landfill leachate.

    Science.gov (United States)

    Oloibiri, Violet; Ufomba, Innocent; Chys, Michael; Audenaert, Wim T M; Demeestere, Kristof; Van Hulle, Stijn W H

    2015-09-01

    The present work investigates the potential of coagulation-flocculation and ozonation to pretreat biologically stabilized landfill leachate before granular activated carbon (GAC) adsorption. Both iron (III) chloride (FeCl3) and polyaluminium chloride (PACl) are investigated as coagulants. Better organic matter removal is observed when leachate was treated with FeCl3. At a dose of 1mg FeCl3/mg CODo (CODo: initial COD content), the COD and α254 removal was 66% and 88%, respectively. Dosing 1mg PACl/mg CODo resulted in 44% COD and 72% α254 removal. The settle-ability of sludge generated by PACl leveled off at 252mL/g, while a better settle-ability of 154mL/g was obtained for FeCl3 after dosing 1mg coagulant/mg CODo. For ozonation, the percentage of COD and α254 removal increased as the initial COD concentration decreased. Respectively 44% COD and 77% α254 removal was observed at 112mg COD/L compared to 5% COD and 26% α254 removal at 1846mg COD/L. Subsequent activated carbon adsorption of ozonated, coagulated and untreated leachate resulted in 77%, 53% and 8% total COD removal after treatment of 6 bed volumes. Clearly showing the benefit of treating the leachate before GAC adsorption. Mathematical modeling of the experimental GAC adsorption data with Thomas and Yoon-Nelson models show that ozonation increases the adsorption capacity and breakthrough time of GAC by a factor of 2.5 compared to coagulation-flocculation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. 137CS in cod from Barents sea

    International Nuclear Information System (INIS)

    Kellermann, H.-J.; Kanisch, G.; Krueger, A.

    2003-01-01

    After publication of the Yablovkov report about dumping of radioactive waste by the former Soviet Union the Institute for Fishery Ecology has analysed fish from Barents Sea for radioactivity. In all studies 137 Cs concentrations in cod fillet showed a clear dependance from fish length. Results from an analysis of covariance for cod of 70 cm length have minor changes within Barents Sea and indicate a rapid decay to a value as is expected for marine fish which is only influenced by global fallout. (orig.)

  1. Removal of organic pollutants in tannery wastewater from wet-blue fur processing by integrated Anoxic/Oxic (A/O) and Fenton: Process optimization

    DEFF Research Database (Denmark)

    Wang, Yong; Li, Weiguang; Angelidaki, Irini

    2014-01-01

    Treatment of tannery wastewater has been a challenge in remediation of aquatic environment in developing countries. Removal of organic pollutants in tannery wastewater from wet-blue fur processing was studied using integrated processes of Anoxic/Oxic and Fenton. Analysis of COD composition based...... 80%. In the subsequent Fenton oxidation, effects of initial pH and H2O2 dose on COD removal were investigated, and response surface methodology was adopted to obtain the optimal conditions as initial pH of 4.0, H2O2 dose of 14.0mM, H2O2:Fe2+ molar ratio of 10.6, and reaction time of 3h to achieve...... the highest COD removal of 55.87%. GC-MS analysis was carried out to observe the change of organic composition during Fenton oxidation, and most of the residual organic pollutants resistant to Fenton treatment belonged to organosilanes and saturated alkanes. This study will provide useful information...

  2. Partial Nitrification and Denitrifying Phosphorus Removal in a Pilot-Scale ABR/MBR Combined Process.

    Science.gov (United States)

    Wu, Peng; Xu, Lezhong; Wang, Jianfang; Huang, Zhenxing; Zhang, Jiachao; Shen, Yaoliang

    2015-11-01

    A pilot-scale combined process consisting of an anaerobic baffled reactor (ABR) and an aerobic membrane bioreactor (MBR) for the purpose of achieving easy management, low energy demands, and high efficiencies on nutrient removal from municipal wastewater was investigated. The process operated at room temperature with hydraulic retention time (HRT) of 7.5 h, recycle ratio 1 of 200%, recycle ratio 2 of 100%, and dissolved oxygen (DO) of 1 mg/L and achieved good effluent quality with chemical oxygen demand (COD) of 25 mg/L, NH4 (+)-N of 4 mg/L, total nitrogen (TN) of 11 mg/L, and total phosphorus (TP) of 0.7 mg/L. The MBR achieved partial nitrification, and NO2 (-)-N has been accumulated (4 mg/L). Efficient short-cut denitrification was occurred in the ABR with a TN removal efficiency of 51%, while the role of denitrification and phosphorus removal removed partial TN (14%). Furthermore, nitrogen was further removed (11%) by simultaneous nitrification and denitrification in the MBR. In addition, phosphorus accumulating organisms in the MBR sufficiently uptake phosphorus; thus, effluent TP further reduced with a TP removal efficiency of 84%. Analysis of fluorescence in situ hybridization (FISH) showed that ammonia oxidizing bacteria (AOB) and phosphorus accumulating organisms (PAOs) were enriched in the process. In addition, the accumulation of NO2 (-)-N was contributed to the inhibition on the activities of the NOB rather than its elimination.

  3. The use of Moringa oleifera seed as a natural coagulant for wastewater treatment and heavy metals removal

    Science.gov (United States)

    Shan, Tan Chu; Matar, Manaf Al; Makky, Essam A.; Ali, Eman N.

    2017-06-01

    Moringa oleifera (MO) is a multipurpose tree with considerable potential and its cultivation is currently being actively promoted in many developing countries. Seeds of this tropical tree contain water-soluble, positively charged proteins that act as an effective coagulant for water and wastewater treatment. Based on this, water quality of "Sungai baluk" river was examined before and after the treatment using MO seed. MO seed exhibited high efficiency in the reduction and prevention of the bacterial growth in both wastewater and "Sungai baluk" river samples. The turbidity was removed up to 85-94% and dissolved oxygen (DO) was improved from 2.58 ± 0.01 to 4.00 ± 0.00 mg/L. The chemical oxygen demand (COD) and biological oxygen demand (BOD) were increased after the treatment from 99.5 ± 0.71 to 164.0 ± 2.83 mg/L for COD and from 48.00 ± 0.42 to 76.65 ± 2.33 mg/L for BOD, respectively. Nevertheless, there was no significant alteration of pH, conductivity, salinity and total dissolved solid after the treatment. Heavy metals such as Fe were fully eliminated, whereas Cu and Cd were successfully removed by up to 98%. The reduction of Pb was also achieved by up to 78.1%. Overall, 1% of MO seed cake was enough to remove heavy metals from the water samples. This preliminary laboratory result confirms the great potential of MO seed in wastewater treatment applications.

  4. Removal of two polycyclic musks in sewage treatment plants: Freely dissolved and total concentrations

    NARCIS (Netherlands)

    Artola-Garicano, E.; Borkent, I.; Hermens, J.L.M.; Vaes, W.H.J.

    2003-01-01

    In the current study, the removal of slowly degradable hydrophobic chemicals in sewage treatment plants (STPs) has been evaluated with emphasis on the combination of free and total concentration data. Free and total concentrations of two polycyclic musks were determined in each compartment of four

  5. The removal of phenols from oily wastewater by chlorine dioxide

    OpenAIRE

    Hsu, Chung-Jung

    1988-01-01

    Treatability studies were performed on oily wastewaters produced by petroleum and canning industries. Chlorine dioxide was used for the removal of phenolic compounds from these oily wastewaters. Most of phenolic compounds can be destroyed by chlorine dioxide within 15 minutes if CI02-to-phenol ratios of higher than 5.0 are provided. Factors such as pH, temperature, and COD have little effect on phenol removal. The effectiveness of chlorine dioxide treatment depends critic...

  6. Modelling axisymmetric cod-ends made of different mesh types

    DEFF Research Database (Denmark)

    Priour, D.; Herrmann, Bent; O'Neill, F.G.

    2009-01-01

    the selectivity process has become more important. This paper presents a model of the deformation of an axisymmetric cod-end. The twine tension and the catch pressure acting on the knots of each mesh along the cod-end profile are calculated, and a Newton-Raphson scheme is used to estimate the equilibrium position...

  7. Assessment of the removal of estrogenicity in biological nutrient removal wastewater treatment processes

    International Nuclear Information System (INIS)

    Ogunlaja, O.O.; Parker, W.J.

    2015-01-01

    The removal of estrogenicity in a University of Cape Town-biological nutrient removal (UCT-BNR) wastewater treatment process was investigated using pilot and bench scale systems, batch experiments and mathematical modeling. In the pilot BNR process, 96 ± 5% of the estrogenicity exerted by the influent wastewater was removed by the treatment process. The degradation efficiencies in the anaerobic, anoxic and aerobic zones of the pilot BNR bioreactor were 11 ± 9%, 18 ± 2% and 93 ± 10%, respectively. In order to further understand the performance of the BNR process in the removal of estrogenicity from wastewater, a bench scale BNR process was operated with synthetic wastewater dosed with E1 and E2. The removal of estrogenicity in the bench scale system (95 ± 5%) was comparable to the pilot BNR process and the degradation efficiencies were estimated to be 8 ± 0.8%, 38 ± 4% and 85 ± 22% in the anaerobic, anoxic and aerobic zones, respectively. A biotransformation model developed to predict the fate of E1 and E2 in batch tests using the sludge from the BNR process was calibrated using the data from the experiments. The biotransformation rate constants for the transformation of E2 to E1 were estimated as 71 ± 1.5, 31 ± 3.3 and 1 ± 0.9 L g COD −1 d −1 for the aerobic, anoxic and anaerobic batch tests, respectively, while the corresponding biotransformation rate constants for the transformation of E1 were estimated to be 7.3 ± 1.0, 3 ± 2.0, and 0.85 ± 0.6 L·g COD −1 d −1 . A steady state mass balance model formulated to describe the interactions between E2 and E1 in BNR activated sludge reasonably described the fate of E1 and E2 in the BNR process. - Highlights: • Comparable estrogenicity removal was observed from two BNR processes. • Pseudo first order model described the transformation of E2 and E1 in BNR process. • Biotransformation of E1 in BNR activated sludge controls the degradation of E2

  8. Assessment of the removal of estrogenicity in biological nutrient removal wastewater treatment processes

    Energy Technology Data Exchange (ETDEWEB)

    Ogunlaja, O.O., E-mail: oogunlaj@uwaterloo.ca; Parker, W.J., E-mail: wjparker@uwaterloo.ca

    2015-05-01

    The removal of estrogenicity in a University of Cape Town-biological nutrient removal (UCT-BNR) wastewater treatment process was investigated using pilot and bench scale systems, batch experiments and mathematical modeling. In the pilot BNR process, 96 ± 5% of the estrogenicity exerted by the influent wastewater was removed by the treatment process. The degradation efficiencies in the anaerobic, anoxic and aerobic zones of the pilot BNR bioreactor were 11 ± 9%, 18 ± 2% and 93 ± 10%, respectively. In order to further understand the performance of the BNR process in the removal of estrogenicity from wastewater, a bench scale BNR process was operated with synthetic wastewater dosed with E1 and E2. The removal of estrogenicity in the bench scale system (95 ± 5%) was comparable to the pilot BNR process and the degradation efficiencies were estimated to be 8 ± 0.8%, 38 ± 4% and 85 ± 22% in the anaerobic, anoxic and aerobic zones, respectively. A biotransformation model developed to predict the fate of E1 and E2 in batch tests using the sludge from the BNR process was calibrated using the data from the experiments. The biotransformation rate constants for the transformation of E2 to E1 were estimated as 71 ± 1.5, 31 ± 3.3 and 1 ± 0.9 L g COD{sup −1} d{sup −1} for the aerobic, anoxic and anaerobic batch tests, respectively, while the corresponding biotransformation rate constants for the transformation of E1 were estimated to be 7.3 ± 1.0, 3 ± 2.0, and 0.85 ± 0.6 L·g COD{sup −1} d{sup −1}. A steady state mass balance model formulated to describe the interactions between E2 and E1 in BNR activated sludge reasonably described the fate of E1 and E2 in the BNR process. - Highlights: • Comparable estrogenicity removal was observed from two BNR processes. • Pseudo first order model described the transformation of E2 and E1 in BNR process. • Biotransformation of E1 in BNR activated sludge controls the degradation of E2.

  9. Implications of stock recovery for a neighbouring management unit: experience from the Baltic cod

    DEFF Research Database (Denmark)

    Eero, Margit; Hansen, Jakob Hemmer; Hüssy, Karin

    2014-01-01

    Cod in the Baltic Sea is assessed and managed as two separate stocks, i.e. eastern and western Baltic cod. The eastern Baltic cod has recently started to recover after several decades of severe depletion. In the present study, we suggest that the recovery of the eastern Baltic cod population has ...

  10. Scenario Analysis of Nutrient Removal from Municipal Wastewater by Microalgal Biofilms

    NARCIS (Netherlands)

    Boelee, N.C.; Temmink, H.; Janssen, M.; Buisman, C.J.N.; Wijffels, R.H.

    2012-01-01

    Microalgae can be used for the treatment of municipal wastewater. The application of microalgal biofilms in wastewater treatment systems seems attractive, being able to remove nitrogen, phosphorus and COD from wastewater at a short hydraulic retention time. This study therefore investigates the area

  11. Plasma FITC-dextran exchange between the primary and secondary circulatory systems in the Atlantic cod, Gadus Morhua

    DEFF Research Database (Denmark)

    Fischer, Claes; Steffensen, John Fleng

    2008-01-01

    Fluorescein isothiocyanate dextran (FITC-dextran) exchange between the primary (PCS) and secondary (SCS) circulatory systems in the Atlantic cod, Gadus morhua (Linnaeus, 1752), were studied using 20-kDa (n = 4) and 500-kDa (n = 4) FITC-dextran. In order to give a qualitative perspective...... of the general connection between the PCS and SCS, distribution of plasma-borne tracers (FITC-dextran) in the PCS and SCS were examined. In this study, a total of eight cod were cannulated in the ventral aorta (PCS) and dorsal cutaneous vessel (SCS), for investigation of FITC-dextran disappearance in the PCS...... and its subsequent appearance in the SCS. FITC-dextran of both sizes was found to be in equilibrium between the PCS and SCS in less than 20 min. This indicates a profound connection between the PCS and SCS in the Atlantic cod, and rapid mixing of tracers between the PCS and SCS. The destination...

  12. Total organic carbon removal from a chemical lab’s wastewater using Fenton’s reagent

    Directory of Open Access Journals (Sweden)

    Oscar Mauricio Martínez Ávila

    2013-05-01

    Full Text Available Treating industrial wastewater represents a serious problem nowadays; it requires a strong understanding of the particular systems and (in most of cases ad hoc solutions. This work describes the use of Fenton’s reagent (reaction between H2O2 and Fe(II for removing total organic carbon (TOC from a particular chemical laboratory’s lab-scale batch reactor wastewater. Some operating variables (hydrogen peroxide and ferrous ion concentration, temperature and pH were evaluated regarding final TOC removal. An economic optimisation was made by means of a second order polynomial model representing these variables’ behaviour regarding TOC removal (0.94 R2. The highest experimentally reached TOC removal was 88.8% at 50 mg/L [Fe(II]0, 50 mM [H2O2]0 , pH=2.8 at 80oC, while 53.9% was obtained in optimised conditions, i.e. 36 mg/L [Fe(II]0 , 45.5 mM [H2O2]0 , pH=2.6 at 20°C. It was found that the Fenton process could achieve 41% removal, even in adverse conditions (pH close to 6. It was noted from the analysis that both H2O2 concentration and temperature had a powerful effect on organic matter degradation efficiency, as well as on total treatment cost.

  13. Estimation of bacterial quality of cod fillets with the disc flotation method

    International Nuclear Information System (INIS)

    Boismenu, D.; Lepine, F.; Thibault, C.; Gagnon, M.; Charbonneau, R.; Dugas, H.

    1991-01-01

    Spoilage bacteria of cod fillets were desorbed off the fillet surface by ultrasonication. Catalase activity of these bacteria was determined using the disc flotation method after selective heat inactivation of the endogenous cod catalase and then correlated with the colony forming units. The method was applied to cod fillets from ten retail sources with satisfactory results

  14. Removal of cyanotoxins from surface water resources using reusable molecularly imprinted polymer adsorbents.

    Science.gov (United States)

    Krupadam, Reddithota J; Patel, Govind P; Balasubramanian, Rajasekhar

    2012-06-01

    Microcystins (MCs; cyclic heptapeptides) are produced by freshwater cyanobacteria and cause public health concern in potable water supplies. There are more than 60 types of MCs identified to date, of which MC-LR is the most common found worldwide. For MC-LR, the WHO has established a threshold value of 1 μg L(-1) for drinking water. The present MCs removal methods such as coagulation, flocculation, adsorption, and filtration showed low efficiency for removing dissolved MC fraction from surface waters to the stipulated limit prescribed by WHO based on MC health impacts. The search for cost-effective and efficient removal method is still warranted for remediation of dissolved MC-LR-contaminated water resources. Molecularly imprinted polymer (MIP) adsorbent has been prepared using non-covalent imprinting approach. Using MC-LR as a template, itaconic acid as a functional monomer, and ethylene glycol dimethacrylate as a cross-linking monomer, a MIP has been synthesized. Computer simulations were used to design effective binding sites for MC-LR binding in aqueous solutions. Batch binding adsorption assay was followed to determine binding capacity of MIP under the influence of environmental parameters such as total dissolved solids and pH. The adsorptive removal of MC-LR from lake water has been investigated using MIPs. The MIP showed excellent adsorption potential toward MC-LR in aqueous solutions with a binding capacity of 3.64 μg mg(-1) which is about 60% and 70% more than the commercially used powdered activated carbon (PAC) and resin XAD, respectively. Environmental parameters such as total organic carbon (represented as chemical oxygen demand (COD)) and total dissolved solids (TDS) showed no significant interference up to 300 mg L(-1) for MC-LR removal from lake water samples. It was found that the binding sites on PAC and XAD have more affinity toward COD and TDS than the MC-LR. Further, the adsorption capacity of the MIP was evaluated rigorously by its repeated

  15. Evaluation of the Efficiency of a Biofilter System’s Phenol Removal From Wastewater

    Directory of Open Access Journals (Sweden)

    Reza Shokoohi

    2016-06-01

    Full Text Available Phenol is a toxic hydrocarbon that has been found in the wastewater of several industries, including the petroleum and petrochemical industries. The discharge of untreated wastewater from these industries causes environmental pollution, especially in water. The aim of this study was to evaluate the efficiency of phenol removal from wastewater using a biofiltration system. In this experimental study, a cylindrical plexiglass biofilter reactor with an effective volume of 12 liters was used. A total of 30 pcs of plastic grid discs were placed inside the reactor by plastic pipes to maintain the biofilm media in the reactor. The microorganisms used in this study were obtained from the biological sludge of a municipal wastewater treatment plant. The reproduction and adaptation of the microorganisms to 500 mg/L of phenol lasted three months. The effects of pH, phenol, nitrogen, phosphorus, glucose concentration, and hydraulic retention time on the biofilter system’s performance was evaluated. The results of this study showed that in optimal conditions, this system can reduce the phenol concentration from 500 mg/L to zero within about 4 hr. Maximum efficiency occurred in pH = 7, and the proper COD/N/P ratio was 100/10/2, respectively. In general, this biofilter system is capable of removing 500 mg/L of phenol concentrations and an organic load of 4 - 4.5 kg COD/m3.d within 4 - 5 hr. with high efficiency.

  16. [Characteristics of nitrogen and phosphorus removal and control of membrane fouling in MBR and SMBR].

    Science.gov (United States)

    Guo, Xiao-Ma; Zhao, Yan; Wang, Kai-Yan; Zhao Yang-Guo

    2015-03-01

    To improve the efficiency and running stability of wastewater advanced treatment, a sequencing membrane bioreactor (SMBR) and a traditional membrane bioreactor (MBR) were used to investigate the characteristics of nitrogen and phosphorus removal, and the effect of anoxic time on treatment systems and membrane fouling. Simultaneously, molecular biology techniques were applied to analyze the composition of microbial community and the structure of suspended sludge. The results showed that SMBR had higher efficiency in removing TN than MBR, which indicated that intermittent aeration could enhance the ability of nitrogen removal. SMBR and MBR had a similar removal efficiency of NH4(+)-N, TP, COD, and turbidity with the removal rates of 94%, 78%, 80%, and 97%, respectively. Extension of SMBR anoxic time had no effect on COD, NH4(+) -N removal but decreased TN and TP removal rate, dropping from 61% and 74% to 46% and 52%, respectively. Intermittent aeration and powder activated carbon (PAC) could both mitigate membrane fouling. The analysis on microbial community indicated that there was no difference in the composition and structure of microbial community between SMBR and MBR. Nitrospira and Dechloromonas were both highly abundant functional groups, which provided the basis for highly efficient control of bioreactors.

  17. Bay-scale population structure in coastal Atlantic cod in Labrador and Newfoundland, Canada

    DEFF Research Database (Denmark)

    Ruzzante, D.E.; Wroblewski, J.S.; Taggart, C.T.

    2000-01-01

    Polymorphisms at five microsatellite DNA loci provide evidence that Atlantic cod Gadus morhua inhabiting Gilbert Bay, Labrador are genetically distinguishable from offshore cod on the north- east Newfoundland shelf and from inshore cod in Trinity Bay, Newfoundland. Antifreeze activity in the bloo...

  18. PREDICTION OF BOD AND COD OF A REFINERY WASTEWATER USING MULTILAYER ARTIFICIAL NEURAL NETWORKS

    Directory of Open Access Journals (Sweden)

    Eldon Raj Rene

    2008-06-01

    Full Text Available In the recent past, artificial neural networks (ANNs have shown the ability to learn and capture non-linear static or dynamic behaviour among variables based on the given set of data. Since the knowledge of internal procedure is not necessary, the modelling can take place with minimum previous knowledge about the process through proper training of the network. In the present study, 12 ANN based models were proposed to predict the Biochemical Oxygen Demand (BOD5 and Chemical Oxygen Demand (COD concentrations of wastewater generated from the effluent treatment plant of a petrochemical industry. By employing the standard back error propagation (BEP algorithm, the network was trained with 103 data points for water quality indices such as Total Suspended Solids (TSS, Total Dissolved Solids (TDS, Phenol concentration, Ammoniacal Nitrogen (AMN, Total Organic Carbon (TOC and Kjeldahl’s Nitrogen (KJN to predict BOD and COD. After appropriate training, the network was tested with a separate test data and the best model was chosen based on the sum square error (training and percentage average relative error (% ARE for testing. The results from this study reveal that ANNs can be accurate and efficacious in predicting unknown concentrations of water quality parameters through its versatile training process.

  19. Continuous energy recovery and nutrients removal from molasses wastewater by synergistic system of dark fermentation and algal culture under various fermentation types.

    Science.gov (United States)

    Ren, Hong-Yu; Kong, Fanying; Ma, Jun; Zhao, Lei; Xie, Guo-Jun; Xing, Defeng; Guo, Wan-Qian; Liu, Bing-Feng; Ren, Nan-Qi

    2018-03-01

    Synergistic system of dark fermentation and algal culture was initially operated at batch mode to investigate the energy production and nutrients removal from molasses wastewater in butyrate-type, ethanol-type and propionate-type fermentations. Butyrate-type fermentation was the most appropriate fermentation type for the synergistic system and exhibited the accumulative hydrogen volume of 658.3 mL L -1 and hydrogen yield of 131.7 mL g -1 COD. By-products from dark fermentation (mainly acetate and butyrate) were further used to cultivate oleaginous microalgae. The maximum algal biomass and lipid content reached 1.01 g L -1 and 38.5%, respectively. In continuous operation, the synergistic system was stable and efficient, and energy production increased from 8.77 kJ L -1  d -1 (dark fermentation) to 17.3 kJ L -1  d -1 (synergistic system). Total COD, TN and TP removal efficiencies in the synergistic system reached 91.1%, 89.1% and 85.7%, respectively. This study shows the potential of the synergistic system in energy recovery and wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Simultaneous phosphate and CODcr removals for landfill leachate using modified honeycomb cinders as an adsorbent

    International Nuclear Information System (INIS)

    Yue Xiu; Li Xiaoming; Wang Dongbo; Shen Tingting; Liu Xian; Yang Qi; Zeng Guangming; Liao Dexiang

    2011-01-01

    In this study, honeycomb cinders were employed to remove phosphate and Chemical Oxygen Demand (COD cr ) simultaneously for landfill leachate treatment. Operating conditions of honeycomb cinders pretreatment, pH, temperature, honeycomb cinders dosage, reaction time, and settling time, were evaluated and optimized. The results revealed that the removal efficiencies of both phosphate and COD cr could be increased up to 99.9% and 66.7% under the optimal conditions, respectively. Moreover, the structures of raw/modified honeycomb cinders and resulting precipitates were detected by Scanning Electron Microscope (SEM), Energy Dispersive Spectrometers (EDS) analysis and X-ray Diffraction (XRD). The results suggested that the adsorption method using honeycomb cinders might be an effective strategy as a pretreatment technology for landfill leachate treatment.

  1. Mechanism, kinetics and application studies on enhanced activated sludge by interior microelectrolysis.

    Science.gov (United States)

    Yang, Xiaoyi; Xue, Yu; Wang, Wenna

    2009-01-01

    Enhanced activated sludge by interior microelectrolysis (EAIM) was studied to treat textile wastewater, kinetics, mechanism and application of which were also discussed in comparison with traditional activated sludge and interior microelectrolysis, respectively. The results of kinetics study indicated three different processes all followed first-order kinetics well. In EAIM, three impact factors take effects on COD removal, which are flocculation, activated sludge and electrophoresis and redox. In terms of assumption of no interaction among three COD removal mechanisms, 49.6% of the total COD removal is ascribed to flocculation, 30.1% to activated sludge and 20.3% to electrophoresis and redox. EAIM showed its advantages in COD removal efficiency, extensive adaptability to complex composition and wide range of pH. EAIM-aerobic process provided an efficient and economic performance for dealing with textile wastewater.

  2. Application of Fenton process to remove organic matter and PCBs from waste (fuller's earth) contaminated with insulating oil.

    Science.gov (United States)

    da Silva, Milady Renata Apolinário; Rodrigues, Eduardo de Oliveira; Espanhol-Soares, Melina; Silva, Flavio Soares; Kondo, Márcia Matiko; Gimenes, Rossano

    2018-01-09

    Polychlorinated biphenyls (PCBs) are carcinogenic to humans and can be found in fuller's earth used for the treatment of used transformer oil. This work describes an optimization of the Fenton process for the removal of contaminants from fuller's earth. The effects of pH (2.5 and 4.0), [H 2 O 2 ] (1.47 and 2.07 mol L -1 ), and [Fe 2+ ] (1.7 and 40 mmol L -1 ) were studied. The Fenton process efficiency was monitored using the decreases in the chemical oxygen demand (COD) and the concentrations of oil and grease, total carbon (TC), PCBs, and H 2 O 2 . The fuller's earth contaminated with insulating oil presented 35% (w/w) of TC, 34% (w/w) of oil and grease, 297.0 g L -1 COD, and 64 mg of PCBs per kg. The material could therefore be considered a dangerous waste. After Fenton treatment, using a slurry mode, there was a removal of 55% of COD, 20% of oil and grease, and 20% of TC, achieved at pH 2.5 using 2.07 mol L -1 of H 2 O 2 and 40.0 mmol L -1 of Fe 2+ . No PCBs were detected in the samples after the Fenton treatment, even using smaller amounts of Fenton reagents (1.47 mol L -1 of H 2 O 2 , 1.7 mmol L -1 of Fe 2+ , pH 2.5). The results indicated that the treated fuller's earth was free from PCB residues and could be disposed of in a simple landfill, in accordance with Brazilian PCB regulations.

  3. Effect of physico-chemical pretreatment on the removal efficiency of horizontal subsurface-flow constructed wetlands

    Energy Technology Data Exchange (ETDEWEB)

    Caselles-Osorio, Aracelly [Environmental Engineering Division, Hydraulics, Coastal and Environmental Engineering Department, Technical University of Catalonia, c/Jordi Girona 1-3, Modul D-1, 08034 Barcelona (Spain); Department of Biology, Atlantic University, Km 7 Higway Old Colombia Port, Barranquilla (Colombia); Garcia, Joan [Environmental Engineering Division, Hydraulics, Coastal and Environmental Engineering Department, Technical University of Catalonia, c/Jordi Girona 1-3, Modul D-1, 08034 Barcelona (Spain)]. E-mail: joan.garcia@upc.edu

    2007-03-15

    In this study, we tested the effect of a physico-chemical pretreatment on contaminant removal efficiency in two experimental horizontal subsurface-flow constructed wetlands (SSF CWs). One SSF CW was fed with settled urban wastewater, whereas the other with the same wastewater after it had undergone a physico-chemical pretreatment. The SSF CWs were operated with three different hydraulic retention times. During the experiments the effluent concentrations of COD, ammonia N and sulfate were very similar, and, therefore, the physico-chemical pretreatment did not improve the quality of the effluents. COD removal efficiency (as percentage or mass surface removal rate) was slightly greater in the SSF CW fed with pretreated wastewater. Ammonia N removal efficiency was, in general, similar in both SSF CWs and very high (80-90%). At the end of the experiments it was observed that in the SSF CW fed with settled wastewater the hydraulic conductivity decreased by a 20%. - A physico-chemical pretreatment may help to reduce the risk of clogging of subsurface-flow constructed wetlands.

  4. Effect of physico-chemical pretreatment on the removal efficiency of horizontal subsurface-flow constructed wetlands

    International Nuclear Information System (INIS)

    Caselles-Osorio, Aracelly; Garcia, Joan

    2007-01-01

    In this study, we tested the effect of a physico-chemical pretreatment on contaminant removal efficiency in two experimental horizontal subsurface-flow constructed wetlands (SSF CWs). One SSF CW was fed with settled urban wastewater, whereas the other with the same wastewater after it had undergone a physico-chemical pretreatment. The SSF CWs were operated with three different hydraulic retention times. During the experiments the effluent concentrations of COD, ammonia N and sulfate were very similar, and, therefore, the physico-chemical pretreatment did not improve the quality of the effluents. COD removal efficiency (as percentage or mass surface removal rate) was slightly greater in the SSF CW fed with pretreated wastewater. Ammonia N removal efficiency was, in general, similar in both SSF CWs and very high (80-90%). At the end of the experiments it was observed that in the SSF CW fed with settled wastewater the hydraulic conductivity decreased by a 20%. - A physico-chemical pretreatment may help to reduce the risk of clogging of subsurface-flow constructed wetlands

  5. Development of simulated groundwater-contributing areas to selected streams, ponds, coastal water bodies, and production wells in the Plymouth-Carver region and Cape Cod, Massachusetts

    Science.gov (United States)

    Carlson, Carl S.; Masterson, John P.; Walter, Donald A.; Barbaro, Jeffrey R.

    2017-12-21

    IntroductionThe U.S. Geological Survey (USGS), in support of the Massachusetts Estuaries Project (MEP), delineated groundwater-contributing areas to various hydrologic receptors including ponds, streams, and coastal water bodies throughout southeastern Massachusetts, including portions of the Plymouth-Carver aquifer system and all of Cape Cod. These contributing areas were delineated over a 6-year period from 2003 through 2008 by using previously published regional USGS groundwater-flow models for the Plymouth-Carver region (Masterson and others, 2009), the Sagamore (western) and Monomoy (eastern) flow lenses of Cape Cod (Walter and Whealan, 2005), and lower Cape Cod (Masterson, 2004). The original USGS groundwater-contributing areas were subsequently revised in some locations by the MEP to remove modeling artifacts or to make the contributing areas more consistent with site-specific hydrologic conditions without further USGS review. This report describes the process used to create the USGS groundwater-contributing areas and provides these model results in their original format in a single, publicly accessible publication.

  6. Hydrolysis of Marine Cod (Gadus Morhua) Head - Utilization of rest raw material from cod for production of ingredients for human consumption

    OpenAIRE

    Meldstad, Fataneh

    2015-01-01

    The main objective of this study was to determine the possibility of utilizing frozen marine cod head for further processing into high-quality and high-yield fish protein hydrolysates. The project included determination of the effect of mincing versus whole head, frozen storage and thawing methods on the composition and yield of FPH. The results show that freezing and thawing of cod head lead to small changes in the composition of raw material and consequently the resulting ...

  7. Novel MBR_based main stream biological nutrient removal process: high performance and microbial community.

    Science.gov (United States)

    Zhang, Chuanyi; Xu, Xinhai; Zhao, Kuixia; Tang, Lianggang; Zou, Siqi; Yuan, Limei

    2018-02-01

    For municipal wastewater treatment, main stream biological nutrient removal (BNR) process is becoming more and more important. This lab-scale study, novel MBR_based BNR processes (named A 2 N-MBR and A 2 NO-MBR) were built. Comparison of the COD removal, results obtained demonstrated that COD removal efficiencies were almost the same in three processes, with effluent concentration all bellowed 30 mg L -1 . However, the two-sludge systems (A 2 N-MBR and A 2 NO-MBR) had an obvious advantage over the A 2 /O for denitrification and phosphorus removal, with the average TP removal rates of 91.20, 98.05% and TN removal rates of 73.00, 79.49%, respectively, higher than that of 86.45 and 61.60% in A 2 /O process. Illumina Miseq sequencing revealed that Candidatus_Accumulibacter, which is capable of using nitrate as an electron acceptor for phosphorus and nitrogen removal simultaneously, was the dominant phylum in both A 2 N-MBR and A 2 NO-MBR process, accounting for 28.74 and 23.98%, respectively. Distinguishingly, major organism groups related to nitrogen and phosphorus removal in A 2 /O system were Anaerolineaceae_uncultured, Saprospiraceae_uncultured and Thauera, with proportions of 11.31, 8.56 and 5.00%, respectively. Hence, the diversity of dominant PAOs group was likely responsible for the difference in nitrogen and phosphorus removal in the three processes.

  8. Eastern Baltic cod recruitment revisited—dynamics and impacting factors

    DEFF Research Database (Denmark)

    Köster, Fritz; Huwer, Bastian; Hinrichsen, Hans-Harald

    2017-01-01

    The Eastern Baltic cod abundance started rapidly to increase in the mid-2000s as evidenced by analytical stock assessments, due to increased recruitment and declining fishing mortality. Since 2014, the analytical stock assessment is not available, leaving the present stock status unclear and cast......The Eastern Baltic cod abundance started rapidly to increase in the mid-2000s as evidenced by analytical stock assessments, due to increased recruitment and declining fishing mortality. Since 2014, the analytical stock assessment is not available, leaving the present stock status unclear...... and casting doubts about the magnitude of the recent increase in recruitment. Earlier studies identified main factors impacting on cod reproductive success to be related to the loss of two out of three spawning areas in the 1980s caused by lack of major Baltic inflows with a concurrent reduction in salinity...... decade, as the period was characterized by an absence of large-scale Baltic inflows since 2003 and persistent anoxic conditions in the bottom water of the deep Baltic basins. This questions the perception of the increased recruitment in later years and challenges our present understanding of cod...

  9. Monitoring cod catches of the Dutch demersal fleet in 2016

    NARCIS (Netherlands)

    Hal, van R.; Machiels, M.A.M.

    2017-01-01

    This report presents the results of the cod monitoring program 2016. The research was commissioned by the Dutch Ministry of Economic Affairs within the EZ-program Beleidsondersteunend Onderzoek. Cod catches of the vessels in the fleet segments BT2 (beam trawl and pulse trawl) and TR (otter trawls

  10. Treatment of oilfield wastewater by combined process of micro-electrolysis, Fenton oxidation and coagulation.

    Science.gov (United States)

    Zhang, Zhenchao

    2017-12-01

    In this study, a combined process was developed that included micro-electrolysis, Fenton oxidation and coagulation to treat oilfield fracturing wastewater. Micro-electrolysis and Fenton oxidation were applied to reduce chemical oxygen demand (COD) organic load and to enhance organic components gradability, respectively. Orthogonal experiment were employed to investigate the influence factors of micro-electrolysis and Fenton oxidation on COD removal efficiency. For micro-electrolysis, the optimum conditions were: pH, 3; iron-carbon dosage, 50 mg/L; mass ratio of iron-carbon, 2:3; reaction time, 60 min. For Fenton oxidation, a total reaction time of 90 min, a H 2 O 2 dosage of 12 mg/L, with a H 2 O 2 /Fe 2+ mole ratio of 30, pH of 3 were selected to achieve optimum oxidation. The optimum conditions in coagulation process: pH, cationic polyacrylamide dosage, mixing speed and time is 4.3, 2 mg/L, 150 rpm and 30 s, respectively. In the continuous treatment process under optimized conditions, the COD of oily wastewater fell 56.95%, 46.23%, 30.67%, respectively, from last stage and the total COD removal efficiency reached 83.94% (from 4,314 to 693 mg/L). In the overall treatment process under optimized conditions, the COD of oily wastewater was reduced from 4,314 to 637 mg/L, and the COD removal efficiency reached 85.23%. The contribution of each stage is 68.45% (micro-electrolysis), 24.07% (Fenton oxidation), 7.48% (coagulation), respectively. Micro-electrolysis is the uppermost influencing process on COD removal. Compared with the COD removal efficiency of three processes on raw wastewater under optimized conditions: the COD removal efficiency of single micro-electrolysis, single Fenton oxidation, single coagulation is 58.34%, 44.88% and 39.72%, respectively. Experiments proved the effect of combined process is marvelous and the overall water quality of the final effluent could meet the class III national wastewater discharge standard of petrochemical industry of China

  11. A bio-economic analysis of harvest control rules for the Northeast Arctic cod fishery.

    Science.gov (United States)

    Eikeset, Anne Maria; Richter, Andries P; Dankel, Dorothy J; Dunlop, Erin S; Heino, Mikko; Dieckmann, Ulf; Stenseth, Nils Chr

    2013-05-01

    Harvest control rules (HCRs) have been implemented for many fisheries worldwide. However, in most instances, those HCRs are not based on the explicit feedbacks between stock properties and economic considerations. This paper develops a bio-economic model that evaluates the HCR adopted in 2004 by the Joint Norwegian-Russian Fishery Commission to manage the world's largest cod stock, Northeast Arctic cod (NEA). The model considered here is biologically and economically detailed, and is the first to compare the performance of the stock's current HCR with that of alternative HCRs derived with optimality criteria. In particular, HCRs are optimized for economic objectives including fleet profits, economic welfare, and total yield and the emerging properties are analyzed. The performance of these optimal HCRs was compared with the currently used HCR. This paper show that the current HCR does in fact comes very close to maximizing profits. Furthermore, the results reveal that the HCR that maximizes profits is the most precautionary one among the considered HCRs. Finally, the HCR that maximizes yield leads to un-precautionary low levels of biomass. In these ways, the implementation of the HCR for NEA cod can be viewed as a success story that may provide valuable lessons for other fisheries.

  12. Chemical or electrochemical techniques, followed by ion exchange, for recycle of textile dye wastewater.

    Science.gov (United States)

    Raghu, S; Ahmed Basha, C

    2007-10-22

    This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.

  13. Developing Baltic cod recruitment models I : Resolving spatial and temporal dynamics of spawning stock and recruitment for cod, herring, and sprat

    DEFF Research Database (Denmark)

    Köster, Fritz; Möllmann, C.; Neuenfeldt, Stefan

    2001-01-01

    The Baltic Sea comprises a heterogeneous oceanographic environment influencing the spatial and temporal potential for reproductive success of cod (Gadus morhua) and sprat (Sprattus sprattus) in the different spawning basins. Hence, to quantify stock and recruitment dynamics, it is necessary......-disaggregated multispecies virtual population analyses (MSVPA) were performed for interacting species cod, herring (Clupea harengus), and sprat in the different subdivisions of the Central Baltic. The MSVPA runs revealed distinct spatial trends in population abundance, spawning biomass, recruitment, and predation...

  14. Long-term groundwater contamination after source removal—The role of sorbed carbon and nitrogen on the rate of reoxygenation of a treated-wastewater plume on Cape Cod, MA, USA

    Science.gov (United States)

    Smith, Richard L.; Repert, Deborah A.; Barber, Larry B.; LeBlanc, Denis R.

    2013-01-01

    The consequences of groundwater contamination can remain long after a contaminant source has been removed. Documentation of natural aquifer recoveries and empirical tools to predict recovery time frames and associated geochemical changes are generally lacking. This study characterized the long-term natural attenuation of a groundwater contaminant plume in a sand and gravel aquifer on Cape Cod, Massachusetts, after the removal of the treated-wastewater source. Although concentrations of dissolved organic carbon (DOC) and other soluble constituents have decreased substantially in the 15 years since the source was removed, the core of the plume remains anoxic and has sharp redox gradients and elevated concentrations of nitrate and ammonium. Aquifer sediment was collected from near the former disposal site at several points in time and space along a 0.5-km-long transect extending downgradient from the disposal site and analyses of the sediment was correlated with changes in plume composition. Total sediment carbon content was generally low (rates in laboratory incubations, which ranged from 11.6 to 44.7 nmol (g dry wt)− 1 day− 1. Total water extractable organic carbon was groundwater velocity. This suggests that the total sorbed carbon pool is large relative to the rate of oxygen entrainment and will be impacting groundwater geochemistry for many decades. This has implications for long-term oxidation of reduced constituents, such as ammonium, that are being transported downgradient away from the infiltration beds toward surface and coastal discharge zones.

  15. Optimization of methane production in anaerobic co-digestion of poultry litter and wheat straw at different percentages of total solid and volatile solid using a developed response surface model.

    Science.gov (United States)

    Shen, Jiacheng; Zhu, Jun

    2016-01-01

    Poultry litter (PL) can be good feedstock for biogas production using anaerobic digestion. In this study, methane production from batch co-digestion of PL and wheat straw (WS) was investigated for two factors, i.e., total solid (2%, 5%, and 10%) and volatile solid (0, 25, and 50% of WS), constituting a 3 × 3 experimental design. The results showed that the maximum specific methane volume [197 mL (g VS)(‑1)] was achieved at 50% VS from WS at 5% TS level. It was estimated that the inhibitory threshold of free ammonia was about 289 mg L(--1), beyond which reduction of methanogenic activity by at least 54% was observed. The specific methane volume and COD removal can be expressed using two response surface models (R(2) = 0.9570 and 0.9704, respectively). Analysis of variance of the experimental results indicated that the C/N ratio was the most significant factor influencing the specific methane volume and COD removal in the co-digestion of these two materials.

  16. Enhanced biological phosphorus removal. Carbon sources, nitrate as electron acceptor, and characterization of the sludge community

    Energy Technology Data Exchange (ETDEWEB)

    Christensson, M

    1997-10-01

    Enhanced biological phosphorus removal (EBPR) was studied in laboratory scale experiments as well as in a full scale EBPR process. The studies were focused on carbon source transformations, the use of nitrate as an electron acceptor and characterisation of the microflora. A continuous anaerobic/aerobic laboratory system was operated on synthetic wastewater with acetate as sole carbon source. An efficient EBPR was obtained and mass balances over the anaerobic reactor showed a production of 1.45 g poly-{beta}-hydroxyalcanoic acids (PHA), measured as chemical oxygen demand (COD), per g of acetic acid (as COD) taken up. Furthermore, phosphate was released in the anaerobic reactor in a ratio of 0.33 g phosphorus (P) per g PHA (COD) formed and 0.64 g of glycogen (COD) was consumed per g of acetic acid (COD) taken up. Microscopic investigations revealed a high amount of polyphosphate accumulating organisms (PAO) in the sludge. Isolation and characterisation of bacteria indicated Acinetobacter spp. to be abundant in the sludge, while sequencing of clones obtained in a 16S rDNA clone library showed a large part of the bacteria to be related to the high mole % G+C Gram-positive bacteria and only a minor fraction to be related to the gamma-subclass of proteobacteria to which Acinetobacter belongs. Operation of a similar anaerobic/aerobic laboratory system with ethanol as sole carbon source showed that a high EBPR can be achieved with this compound as carbon source. However, a prolonged detention time in the anaerobic reactor was required. PHA were produced in the anaerobic reactor in an amount of 1.24 g COD per g of soluble DOC taken up, phosphate was released in an amount of 0.4-0.6 g P per g PHA (COD) produced and 0.46 g glycogen (COD) was consumed per g of soluble COD taken up. Studies of the EBPR in the UCT process at the sewage treatment plant in Helsingborg, Sweden, showed the amount of volatile fatty acids (VFA) available to the PAO in the anaerobic stage to be

  17. Efficient Total Nitrogen Removal in an Ammonia Gas Biofilter through High-Rate OLAND

    DEFF Research Database (Denmark)

    De Clippeleir, Haydée; Courtens, Emilie; Mosquera, Mariela

    2012-01-01

    Ammonia gas is conventionally treated in nitrifying biofilters; however, addition of organic carbon to perform post-denitrification is required to obtain total nitrogen removal. Oxygen-limited autotrophic nitrification/denitrification (OLAND), applied in full-scale for wastewater treatment, can...... offer a cost-effective alternative for gas treatment. In this study, the OLAND application thus was broadened toward ammonia loaded gaseous streams. A down flow, oxygen-saturated biofilter (height of 1.5 m; diameter of 0.11 m) was fed with an ammonia gas stream (248 ± 10 ppmv) at a loading rate of 0...... at water flow rates of 1.3 ± 0.4 m3 m–2 biofilter section d–1. Profile measurements revealed that 91% of the total nitrogen activity was taking place in the top 36% of the filter. This study demonstrated for the first time highly effective and sustainable autotrophic ammonia removal in a gas biofilter...

  18. Cultivation of Chlorella vulgaris in a pilot-scale photobioreactor using real centrate wastewater with waste glycerol for improving microalgae biomass production and wastewater nutrients removal.

    Science.gov (United States)

    Ren, Hongyan; Tuo, Jinhua; Addy, Min M; Zhang, Renchuan; Lu, Qian; Anderson, Erik; Chen, Paul; Ruan, Roger

    2017-12-01

    To improve nutrients removal from real centrate wastewater and enhance the microalgae biomass production, cultivation of Chlorella vulgaris in lab and a pilot-scale photobioreactor with waste glycerol was studied. The results showed the optimal concentration of the crude glycerol was 1.0gL -1 with the maximum biomass productivity of 460mgL -1 d -1 TVS, the maximum lipid content of 27%, the nutrient removal efficiency of all above 86%, due to more balanced C/N ratio. The synergistic relationship between the wastewater-borne bacteria and the microalgae had significant good influence on nutrient removal. In pilot-scale wastewater-based algae cultivation, with 1gL -1 waste glycerol addition, the average biomass production of 16.7gm -2 d -1 , lipid content of 23.6%, and the removal of 2.4gm -2 d -1 NH 4 + -N, 2.7gm -2 d -1 total nitrogen, 3.0gm -2 d -1 total phosphorous, and 103.0gm -2 d -1 of COD were attained for 34days semi-continuous mode. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Fibreglass Total Contact Casting, Removable Cast Walkers, and Irremovable Cast Walkers to Treat Diabetic Neuropathic Foot Ulcers: A Health Technology Assessment

    Science.gov (United States)

    Costa, Vania; Tu, Hong Anh; Wells, David; Weir, Mark; Holubowich, Corinne; Walter, Melissa

    2017-01-01

    Background Diabetic neuropathic foot ulcers are a risk factor for lower leg amputation. Many experts recommend offloading with fibreglass total contact casting, removable cast walkers, and irremovable cast walkers as a way to treat these ulcers. Methods We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences for offloading devices. We performed a systematic literature search on August 17, 2016, to identify randomized controlled trials that compared fibreglass total contact casting, removable cast walkers, and irremovable cast walkers with other treatments (offloading or non-offloading) in patients with diabetic neuropathic foot ulcers. We developed a decision-analytic model to assess the cost-effectiveness of fibreglass total contact casting, removable cast walkers, and irremovable cast walkers, and we conducted a 5-year budget impact analysis. Finally, we interviewed people with diabetes who had lived experience with foot ulcers, asking them about the different offloading devices and the factors that influenced their treatment choices. Results We identified 13 randomized controlled trials. The evidence suggests that total contact casting, removable cast walkers, and irremovable cast walkers are beneficial in the treatment of neuropathic, noninfected foot ulcers in patients with diabetes but without severe peripheral arterial disease. Compared to removable cast walkers, ulcer healing was improved with total contact casting (moderate quality evidence; risk difference 0.17 [95% confidence interval 0.00–0.33]) and irremovable cast walkers (low quality evidence; risk difference 0.21 [95% confidence interval 0.01–0.40]). We found no difference in ulcer healing between total contact casting and irremovable cast walkers (low quality evidence; risk difference 0.02 [95% confidence interval −0.11–0.14]). The economic analysis showed that total contact casting and irremovable

  20. Removal of macro-pollutants in oily wastewater obtained from soil remediation plant using electro-oxidation process.

    Science.gov (United States)

    Zolfaghari, Mehdi; Drogui, Patrick; Blais, Jean François

    2018-03-01

    Electro-oxidation process by niobium boron-doped diamond (Nb/BDD) electrode was used to treat non-biodegradable oily wastewater provided from soil leachate contaminated by hydrocarbons. Firstly, the diffusion current limit and mass transfer coefficient was experimentally measured (7.1 mA cm -2 and 14.7 μm s -1 , respectively), in order to understand minimum applied current density. Later on, the oxidation kinetic model of each pollutant was investigated in different current densities ranged between 3.8 and 61.5 mA cm -2 . It was observed that direct oxidation was the main removal mechanism of organic and inorganic carbon, while the indirect oxidation in higher current density was responsible for nitrogen oxidation. Hydrocarbon in the form of colloidal particles could be removed by electro-flotation. On the other hand, electro-decomposition on the surface of cathode and precipitation by hydroxyl ions were the utmost removal pathway of metals. According to the initial experiments, operating condition was further optimized by central composite design model in different current density, treatment time, and electrolyte addition, based on the best responses on the specific energy consumption (SEC), chemical oxygen demand (COD), and total organic carbon (TOC) removal efficiency. Unde r optimum operating condition (current density = 23.1 mA cm -2 , time = 120 min, Ti/Pt as a cathode, and Nb/BDD as the anode), electro-oxidation showed the following removal efficiencies: COD (84.6%), TOC (68.2%), oil and grease (99%), color (87.9%), total alkalinity (92%), N tot (18%), NH 4 + (31%), Ca (66.4%), Fe (71.1%), Mg (41.4%), Mn (78.1%), P tot (75%), S (67.1%), and Si (19.1%). Graphical abstract Environmental significance statement Soil treatment facilities are rapidly grown throughout the world, especially in North America due to its intense industrialization. High water content soil in humid area like Canada produces significant amount of leachate which is

  1. Inversion of CDOM and COD in water using HJ-1/CCD data

    International Nuclear Information System (INIS)

    Huang, Miaofen; Xing, Xufeng; Zhao, Zulong; Li, Zhanqiang; Wang, Xinxing

    2014-01-01

    With the in-situ measurement data including the absorption coefficient of the CDOM, apparent optical properties and the COD, a regression model was established for retrieving ag(440) based on the remote sensing reflectance of the first and the third band of the environment satellite HJ-1/CCD. The measurement data were obtained at the regions of Panjin, Liaoning province in May 2008 and August 2009. Secondly, the remote sensing regression model was created based on the correlation of the CDOM optical properties and the COD. Finally, using the HJ-1/CCD data from 2009 to 2011 in Liaodong bay, the thematic snapshots of water environmental parameters in coastal waters, such as the CDOM and the COD, were calculated and analyzed. The results showed that: (1) the distribution of the CDOM tends to decrease from offshore areas to distant sea with some zonated character; (2) Most of the retrieved CDOM values vary between 0.2–1.7m-1, which is consistent with the measured value in 2009 and 2010 years; (3) the spatial distribution of the COD has good consistency with the CDOM, also shows a certain zonated distribution in coastal-offshore areas; (4) in September 2009 and September 2011, the values of the COD was basically below 40 mg/L while the values of the COD in September 2010 are relatively higher, mostly above 55 mg/L; (5) in June 2011 and May 2010, the COD values are nearly all larger than 55 mg/L

  2. Fluidized bed bioreactors coupled to zero-valent iron filters for removal of high concentrations of perchloroethylene

    International Nuclear Information System (INIS)

    Poggi-Varaldo, H. M.; Herrera-Lopez, D.; Garcia-Mena, J.; Rios-Leal, E.

    2009-01-01

    The aim of this work was to evaluate the effect of coupling continuous bioreactors with zero-valent iron filters on removal of PCE. Two types of reactors with simultaneous electron acceptors were used: partially aerated methanogenic (PAM) and methanogenic-denitrifying (M-D). Lab-scale fluidized-bed reactors (FBBR) were operated as follows: PAM at λ=135 g COD/g O 2 and M-D at λ=9 g COD/g N-NO 3 with 80 mg/L of PCE in the influent. (Author)

  3. A millennium of north-east Atlantic cod juvenile growth trajectories inferred from archaeological otoliths.

    Directory of Open Access Journals (Sweden)

    Guðbjörg Ásta Ólafsdóttir

    Full Text Available Archaeological excavations of historical fishing sites across the North Atlantic have recovered high quantities of Atlantic cod (Gadus morhua bones. In the current study we use Atlantic cod otoliths from archaeological excavations of a historical fishing sites in north-west Iceland, dated to AD 970 -AD 1910 to examine historical growth trajectories of cod. No large scale growth variations or shifts in growth patterns were observed in the current chronologies, supporting the stability of historical Atlantic cod growth trajectories. The most significant variation in growth patterns was consistent with those that have been observed in recent times, for example, reduced early juvenile growth during periods of colder ocean temperature. The current results represent a high resolution chronological record of north-east Atlantic cod growth, greatly increasing the prior temporal range of such data, thereby providing a valuable baseline for a broad range of studies on Atlantic cod growth.

  4. Differential Survival among Batches of Atlantic Cod (Gadus morhua L. from Fertilisation through to Post-Metamorphosis.

    Directory of Open Access Journals (Sweden)

    Petra E Petersen

    Full Text Available Aquaculture production of cod has decreased from over 20,000 tonnes in 2009 to less than 2,000 tonnes in 2014 and the industry faces many challenges, one of which is high and unpredictably variable mortality rates in the early life stages. Hence, full-cycle farming with hatchery produced juveniles is still considered unprofitable compared to fisheries and on-growing of wild cod. In the present study, potential batch differences in progeny survival of wild-caught, hatchery-spawned Faroe Bank cod (Gadus morhua L. were investigated at two defined periods during early life history; i the embryo stage (60 day degrees post fertilisation and ii the fry stage (110 days post hatch, post metamorphosis. The fry stage experiment was conducted in three replicates (N = 300 per replicate, and a panel of three polymorphic microsatellite markers was used for parental analysis. Mean survival rate at the embryo stage was 69% (± 20% SD. Survival was positively associated with egg diameter (P < 0.01, explaining 90% of the variation in egg survival rates. The data were too scarce to conclude either way concerning a possible correlation between survival rates between the two periods (P < 0.10. Offspring from three batches (from a total of eight dominated in the fry stage, contributing over 90% of the progeny, and results were consistent over all three replicate tanks. The skewed batch representation observed may be of relevance to the effective management of selective breeding programmes for cod.

  5. Effect of membrane properties on the performance of a hybrid GAC and ultrafiltration process for water treatment.

    Science.gov (United States)

    Qiao, Tiejun; Wu, Guangxue; Zhang, Xihui; Au, Doris W T; Zhang, Jinsong

    2012-06-01

    The performance of a hybrid granular activated carbon (GAC) and ultrafiltration (UF) process for water treatment was investigated using five types of UF membranes. The removal percentages for chemical oxygen demand (COD(Mn)), particles (> or = 2 microm) and total bacteria by the hybrid process were 30-40%, 98-99% and 76-92%, respectively. No invertebrates were detected in the hybrid process effluent. Transmembrane pressure and specific permeate flux (SPF) of the five types of membranes varied. With decreasing membrane pore sizes, removal of COD(Mn) and particles increased, whereas SPF firstly decreased and then increased. Hydrophilic membranes had a relatively high COD(Mn) removal potential, but did not obviously affect particle removal or SPF.

  6. Performance of a haloalkaliphilic bioreactor and bacterial community shifts under different COD/SO{sub 4}{sup 2−} ratios and hydraulic retention times

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jie-Min [National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Song, Zi-Yu [National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China); Yan, Dao-Jiang; Liu, Yi-Lan [National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Yang, Mao-Hua [National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China); Cao, Hong-Bin [National Engineering Laboratory for Hydrometallurgical Cleaner Production Technology, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China); Xing, Jian-Min, E-mail: jmxing@home.ipe.ac.cn [National Key Laboratory of Biochemical Engineering, Institute of Process Engineering, Chinese Academy of Sciences, PO Box 353, Beijing 100190 (China)

    2014-06-01

    Highlights: • Haloalkaliphilic microorganisms were used to reduce sulfate. • Sulfide concentration reached up to 1603 mg/L. • There was no sulfide inhibition to haloalkaliphilic microorganisms. • Bacterial community of haloalkaliphilic bioreactor was studied. - Abstract: Sulfur dioxide from flue gas was converted into sulfate after the absorption of alkaline solutions. Haloalkaliphilic microorganisms have been used in reducing sulfate to decrease expenses and avoid sulfide inhibition. The effects of different COD/SO{sub 4}{sup 2−} ratios and hydraulic retention times (HRTs) on the sulfate removal efficiency and bacterial community were investigated in model experiments. Ethanol showed better performance as an electron donor than lactate. The optimum COD/SO{sub 4}{sup 2−} ratio and HRT were 4.0 and 18 h, respectively, with respective sulfate removal efficiency and rate of 97.8 ± 1.11% and 6.26 ± 0.0710 g/L d. Sulfide concentrations reached 1603 ± 3.38 mg/L. Based on denaturing gradient gel electrophoresis analysis of 16S rDNA, the major sulfate-reducing bacterium (SRB) was Desulfonatronovibrio sp., which was only detected at a COD/SO{sub 4}{sup 2−} ratio of 4.0 using ethanol as an electron donor. Different HRTs had no significant effect on the band corresponding to this species. PCR results show that methane-producing archaea (MPA) were from the acetoclastic methanogenic family Methanosarcinaceae. Quantitative real-time PCR did not demonstrate any significant competition between SRB and MPA. The findings of this study indicate that sulfate reduction, nitrate reduction, and sulfide oxidization may occur in the same bioreactor.

  7. Removal of eutrophication factors and heavy metal from a closed cultivation system using the macroalgae, Gracilaria sp. (Rhodophyta)

    Science.gov (United States)

    Kang, Kyoung Ho; Sui, Zhenghong

    2010-11-01

    In this study, the ability of macroalgae Gracilaria sp. of removing eutrophication factors and toxic heavy metals Al, Cr, and Zn in a closed cultivation system is reported. The results show that the concentration of the three heavy metals decreased significantly during the experimental period in an algal biomass dependent manner. The biofiltration capacity of the alga for Al, Cr, and Zn is 10.1%-72.6%, 52.5%-83.4% and 36.5%-91.7%, respectively. Using more materials resulted in stronger heavy metal removal. Additionally, the concentration of chl- a, TN, TP and DIN of water samples from aquariums involving large, medium, and small algal biomass cultivation increased first and then decreased during the experiment. COD value of all three groups decreased with time and displayed algal biomass dependency: more algae resulting in a greater COD value than those of less biomass. Furthermore, changes in COD reflect an obvious organic particles deprivation process of algae. This is the first report on heavy metal removal effect by Gracilaria species. The results suggest that macroalgae can be used as a biofilter for the treatment of nutrient-enriched or heavy-metal polluted water, to which an appropriate time range should be carefully determined.

  8. Photo-removal of sulfamethoxazole (SMX) by photolytic and photocatalytic processes in a batch reactor under UV-C radiation (λmax = 254 nm)

    International Nuclear Information System (INIS)

    Nasuhoglu, Deniz; Yargeau, Viviane; Berk, Dimitrios

    2011-01-01

    In this study, photolytic and photocatalytic removal of the antibiotic sulfamethoxazole (SMX) under UVC radiation (λ = 254 nm) was investigated. The light intensity distribution inside the batch photoreactor was characterized by azoxybenzene actinometry. The intensity of incident radiation was found to be a strong function of position inside the reactor. 12 mg L -1 of SMX was completely removed within 10 min of irradiation under UVC photolysis, compared to 30 min under TiO 2 photocatalysis. COD measurement was used as an indication of the mineralization efficiency of both processes and higher COD removal with photocatalysis was shown. After 6 h of reaction with photolysis and photocatalysis, 24% and 87% removal of COD was observed, respectively. Two of the intermediate photo-products were identified as sulfanilic acid and 3-amino-5-methylisoxazole by direct comparison of the HPLC chromatograms of standards to those of treated solutions. Ecotoxicity of treated and untreated solutions of SMX towards Daphnia magna was also investigated. It was found that a 3:1 ratio of sample to standard freshwater and a high initial concentration of 60 mg L -1 of SMX were used to obtain reliable and reproducible results. The photo-products formed during photocatalytic and photolytic processes were shown to be generally more toxic than the parent compound.

  9. Combined process of electrocoagulation and photocatalytic degradation for the treatment of olive washing wastewater.

    Science.gov (United States)

    Ates, Hasan; Dizge, Nadir; Yatmaz, H Cengiz

    2017-01-01

    In this study, an electrocoagulation reactor (ECR) and photocatalytic reactor (PCR) were tested to understand the performance of combined electrocoagulation and photocatalytic-degradation of olive washing wastewater (OWW). The effects of initial pH (6.0, 6.9, 8.0, 9.0), applied voltage (10.0, 12.5, 15.0 V), and operating time (30, 60, 90, 120 min) were investigated in the electrocoagulation reactor when aluminum electrodes were used as both anode and cathode. The pH, conductivity, color, chemical oxygen demand (COD), and phenol were measured versus time to determine the efficiency of the ECR and PCR process. It was observed that electrocoagulation as a single treatment process supplied the COD removal of 62.5%, color removal of 98.1%, and total phenol removal of 87% at optimum conditions as pH 6.9, applied voltage of 12.5 V, and operating time of 120 min. Moreover, final pH and conductivity were 7.7 and 980 μS/cm, respectively. On the other hand, the effect of semiconductor catalyst type (TiO 2 and ZnO) and loading (1, 2, 3 g/L) were tested using PCR as a stand-alone technique. It was found that photocatalytic degradation as a single treatment process when using 1 g/L ZnO achieved the COD removal of 46%, color removal of 99% with a total phenol removal of 41% at optimum conditions. Final pH and conductivity were 6.2 and 915 μS/cm, respectively. Among semiconductor catalysts, TiO 2 and ZnO performed identical efficiencies for both COD and total phenol removal. Moreover, combination in which electrochemical degradation was employed as a pre-treatment to the photocatalytic degradation process obtained high COD removal of 88% and total phenol, as well as color removal of 100% for the OWW. The electrochemical treatment alone was not effective, but in combination with the photocatalytic process, led to a high-quality effluent. Finally, sludge collected from the electrocoagulation process was characterized by attenuated total reflection Fourier transform infrared and X

  10. Removal of Furfural From Wastewater Using Integrated Catalytic Ozonation and Biological Approaches

    Directory of Open Access Journals (Sweden)

    Mostafa Leili

    2014-12-01

    Full Text Available Furfural with a chemical formula of C5H4O2 is a toxic compound which has several health problems for both humans and environment. It has a few exposure routes for entering the human body such as oral, dermal or nasal. In the present study, the efficacies of an integrated catalytic ozonation process (COP and novel cyclic biological reactor (CBR were explored for the removal of furfural from aqueous solutions. Activated carbon was purchased from Merck Company. It had a Brunauer, Emmett, and Teller (BET specific surface area of 1100 m2/g, with an average micropore volume and size of 0.385 cm3/g and 595 µm, respectively. The results indicated that 30% pretreatment with COP could increase furfural and chemical oxygen demand (COD removal efficiency with CBR 5.56% and 27.01%, respectively. With 70% pretreatment by COP, 98.57% furfural and 95.34% COD removal efficiencies happen in CBR. Generally, batch and continuous experiments showed that the integrated COP/CBR could be efficient in eliminating furfural from wastewater and thus may be a promising technique for treating furfural-containing wastewater.

  11. Simultaneous removal and evaluation of organic substrates and NH3-N by a novel combined process in treating chemical synthesis-based pharmaceutical wastewater

    International Nuclear Information System (INIS)

    Chen, Zhaobo; Wang, Hongcheng; Ren, Nanqi; Cui, Minhua; Nie, Shukai; Hu, Dongxue

    2011-01-01

    Highlights: ► We research a novel combined process to treat chemical synthesis-based pharmaceutical wastewater. ► The mechanism of amoxicillin verifies that the biodegradation, adsorption, hydrolysis and unknown mechanism were able to remove amoxicillin from wastewater. ► In this study demonstrates that biodegradation is the major factor for removal mechanism at work for amoxicillin. ► Mathematical statistic methods were employed to evaluate the performance of the WWTP. - Abstract: A full-scale novel combined anaerobic/micro-aerobic and two-stage aerobic biological process is used for the treatment of an actual chemical synthesis-based pharmaceutical wastewater containing amoxicillin. The anaerobic system is an up-flow anaerobic sludge blanket (UASB), the micro-aerobic system is a novel micro-aerobic hydrolysis acidification reactor (NHAR) and the two-stage aerobic process comprised cyclic activated sludge system (CASS) and biological contact oxidation tank (BCOT). The influent wastewater was high in COD, NH 3 -N varying daily 4016–13,093 mg-COD L −1 and 156.4–650.2 mg-NH 3 -N L −1 , amoxicillin varying weekly between 69.1 and 105.4 mg-amoxicillin L −1 , respectively; Almost all the COD, NH 3 -N, amoxicillin were removed by the biological combined system, with removal percentages 97%, 93.4% and 97.2%, respectively, leaving around 104 mg-COD L −1 , 9.4 mg-NH 3 -N L −1 and 2.6 ± 0.8 mg-amoxicillin L −1 in the final clarifier effluent. The performance evaluation of the wastewater treatment plant (WWTP) by mathematical statistic methods shown that at most of time effluent can meet the higher treatment discharge standard. In addition, the fate of amoxicillin in the full-scale WWTP and the amoxicillin removal rate of each different removal routes in UASB, NHAR, CASS, BCOT and final clarifier processes are investigated in this paper. The results show that biodegradation, adsorption and hydrolysis are the major mechanisms for amoxicillin removal.

  12. Geographical trends of PFAS in cod livers along the Norwegian coast.

    Science.gov (United States)

    Valdersnes, Stig; Nilsen, Bente M; Breivik, Joar F; Borge, Asbjørn; Maage, Amund

    2017-01-01

    The level of perfluorinated alkyl substances (PFAS) was determined in North East Arctic cod (Gadus morhua) liver samples from 15 Norwegian fjords and harbors. Five harbors in the eastern part of Norway, six harbors in the western part and four harbours in the northern part. A total of 200 samples were analyzed for 16 PFAS. Determination of PFAS were carried out by LC-MS/MS following sample clean up by solid phase extraction and ultracentrifugation. The predominating PFAS was PFOS, which was found to be higher than the level of quantification (1.5 μg kg-1 wet weight) in 72% of the samples. The highest level of PFOS found was 21.8 μg kg-1 wet weight in a sample from Kragerø in the eastern part of Norway. A significantly higher level of PFOS was found in the eastern fjords and harbors compared to fjords and harbors in the western and northern part of Norway. Within the northern fjords and harbors elevated PFOS levels were found in Narvik, which may indicate a local source there. Variations in PFOS of the cod livers thus reflect differences in levels of pollution between the areas.

  13. Performance of the constructed wetland systems in pollutants removal from hog wastewater

    Directory of Open Access Journals (Sweden)

    Wallison da Silva Freitas

    2010-08-01

    Full Text Available The main objective of this work was to evaluate the efficiency of a constructed wetland systems (CWS for pollutants removal, in mono crop and multi crop with three different species of plants, originated from hog wastewater treatment (HW. Therefore, 5 CWS of 24.0 m x 1.1 m x 0.7 m were constructed, sealed with a membrane of polyvinyl chloride (PVC and filled with 0.4 m of small gravel. In CWS1, CWS2 and CWS3 grown to cattail (Typha latifolia L., Alternanthera philoxeroides (Mart. Griseb. and Tifton 85 grass (Cynodon dactylon Pers., respectively. In the bed of CWS4 was planted at 1st third Alternanthera, cattail, in the 2nd third and tifton-85 grass and in the 3rd third of. The CWS5 was not planted and it was used as control. After passing through a filter filled with crushed bagasse of sugar cane, the HW was applied to the CWS in a flow of 0.8 m3 d-1, which corresponded to a hydraulic detention time of 4.8 days. According to the results it was shown that the five CWS(s had statistically nearly the same removal of pollutants, and the average removal efficiency of TSS, COD, BOD and Zn, were 91, 89, 86 and 94%, respectively. Also high removals were obtained concerning the ST, N-total, NH4+ and P-total, with average values of 62, 59, 52 and 50%, respectively. The plants in all planted CWS worked in a similar way maintaining the system efficiency and the non cultivated CWS presented analogous capacity of pollutants removal when compared to the cultivated CWS(s.

  14. Combined biodegradation and ozonation for removal of tannins and dyes for the reduction of pollution loads.

    Science.gov (United States)

    Kanagaraj, James; Mandal, Asit Baran

    2012-01-01

    Tannins and dyes pose major threat to the environment by generating huge pollution problem. Biodegradation of wattle extract, chrome tannin and dye compounds using suitable fungal culture namely Aspergillus niger, Penicillium sp. were carried out. In addition to these, ozone treatment was carried out to get higher degradation rate. The results were monitored by carrying out chemical oxygen demand (COD), total organic carbon (TOC), and UV-Vis analysis. The results showed that wattle extract (vegetable tannin) gave better biodegradation rate than dye and chromium compounds. Biodegradation plus ozone showed degradation rates of 92-95%, 94-95%, and 85-87% for the wattle extract, dyes, chromium compounds, respectively. UV-Vis showed that there were no peaks observed for biodegraded samples indicating better degradation rates as compared to the control samples. FT-IR spectra analysis suggested that the formation of flavanoid derivatives, chromic oxide and NH(2) compounds during degradation of wattle extract, chromium and dye compounds, respectively, at the peaks of 1,601-1,629 cm(-1), 1,647 cm(-1), and 1,610-1,680 cm(-1). The present investigation shows that combination of biodegradation with ozone is the effective method for the removal of dyes and tannins. The biodegradation of the said compounds in combination with ozonation showed better rate of degradation than by chemical methods. The combination of biodegradation with ozone helps to reduce pollution problems in terms of COD, TOC, total dissolved solids and total suspended solids.

  15. Application of Box-Wilson experimental design method for 2,4-dinitrotoluene treatment in a sequential anaerobic migrating blanket reactor (AMBR)/aerobic completely stirred tank reactor (CSTR) system

    International Nuclear Information System (INIS)

    Kuscu, Ozlem Selcuk; Sponza, Delia Teresa

    2011-01-01

    A sequential aerobic completely stirred tank reactor (CSTR) following the anaerobic migrating blanket reactor (AMBR) was used to treat a synthetic wastewater containing 2,4-dinitrotoluene (2,4-DNT). A Box-Wilson statistical experiment design was used to determine the effects of 2,4-DNT and the hydraulic retention times (HRTs) on 2,4-DNT and COD removal efficiencies in the AMBR reactor. The 2,4-DNT concentrations in the feed (0-280 mg/L) and the HRT (0.5-10 days) were considered as the independent variables while the 2,4-DNT and chemical oxygen demand (COD) removal efficiencies, total and methane gas productions, methane gas percentage, pH, total volatile fatty acid (TVFA) and total volatile fatty acid/bicarbonate alkalinity (TVFA/Bic.Alk.) ratio were considered as the objective functions in the Box-Wilson statistical experiment design in the AMBR. The predicted data for the parameters given above were determined from the response functions by regression analysis of the experimental data and exhibited excellent agreement with the experimental results. The optimum HRT which gave the maximum COD (97.00%) and 2,4-DNT removal (99.90%) efficiencies was between 5 and 10 days at influent 2,4-DNT concentrations 1-280 mg/L in the AMBR. The aerobic CSTR was used for removals of residual COD remaining from the AMBR, and for metabolites of 2,4-DNT. The maximum COD removal efficiency was 99% at an HRT of 1.89 days at a 2,4-DNT concentration of 239 mg/L in the aerobic CSTR. It was found that 280 mg/L 2,4-DNT transformed to 2,4-diaminotoluene (2,4-DAT) via 2-amino-4-nitrotoluene (2-A-4-NT) and 4-amino-2-nitrotoluene (4-A-2-NT) in the AMBR. The maximum 2,4-DAT removal was 82% at an HRT of 8.61 days in the aerobic CSTR. The maximum total COD and 2,4-DNT removal efficiencies were 99.00% and 99.99%, respectively, at an influent 2,4-DNT concentration of 239 mg/L and at 1.89 days of HRT in the sequential AMBR/CSTR.

  16. Application of Box-Wilson experimental design method for 2,4-dinitrotoluene treatment in a sequential anaerobic migrating blanket reactor (AMBR)/aerobic completely stirred tank reactor (CSTR) system

    Energy Technology Data Exchange (ETDEWEB)

    Kuscu, Ozlem Selcuk, E-mail: oselcuk@mmf.sdu.edu.tr [Department of Environmental Engineering, Engineering and Architecture Faculty, Sueleyman Demirel University, Cuenuer Campus, 32260 Isparta (Turkey); Sponza, Delia Teresa [Dokuz Eyluel University, Engineering Faculty, Environmental Engineering Department, Buca Kaynaklar campus, Izmir (Turkey)

    2011-03-15

    A sequential aerobic completely stirred tank reactor (CSTR) following the anaerobic migrating blanket reactor (AMBR) was used to treat a synthetic wastewater containing 2,4-dinitrotoluene (2,4-DNT). A Box-Wilson statistical experiment design was used to determine the effects of 2,4-DNT and the hydraulic retention times (HRTs) on 2,4-DNT and COD removal efficiencies in the AMBR reactor. The 2,4-DNT concentrations in the feed (0-280 mg/L) and the HRT (0.5-10 days) were considered as the independent variables while the 2,4-DNT and chemical oxygen demand (COD) removal efficiencies, total and methane gas productions, methane gas percentage, pH, total volatile fatty acid (TVFA) and total volatile fatty acid/bicarbonate alkalinity (TVFA/Bic.Alk.) ratio were considered as the objective functions in the Box-Wilson statistical experiment design in the AMBR. The predicted data for the parameters given above were determined from the response functions by regression analysis of the experimental data and exhibited excellent agreement with the experimental results. The optimum HRT which gave the maximum COD (97.00%) and 2,4-DNT removal (99.90%) efficiencies was between 5 and 10 days at influent 2,4-DNT concentrations 1-280 mg/L in the AMBR. The aerobic CSTR was used for removals of residual COD remaining from the AMBR, and for metabolites of 2,4-DNT. The maximum COD removal efficiency was 99% at an HRT of 1.89 days at a 2,4-DNT concentration of 239 mg/L in the aerobic CSTR. It was found that 280 mg/L 2,4-DNT transformed to 2,4-diaminotoluene (2,4-DAT) via 2-amino-4-nitrotoluene (2-A-4-NT) and 4-amino-2-nitrotoluene (4-A-2-NT) in the AMBR. The maximum 2,4-DAT removal was 82% at an HRT of 8.61 days in the aerobic CSTR. The maximum total COD and 2,4-DNT removal efficiencies were 99.00% and 99.99%, respectively, at an influent 2,4-DNT concentration of 239 mg/L and at 1.89 days of HRT in the sequential AMBR/CSTR.

  17. Application of Box-Wilson experimental design method for 2,4-dinitrotoluene treatment in a sequential anaerobic migrating blanket reactor (AMBR)/aerobic completely stirred tank reactor (CSTR) system.

    Science.gov (United States)

    Kuşçu, Özlem Selçuk; Sponza, Delia Teresa

    2011-03-15

    A sequential aerobic completely stirred tank reactor (CSTR) following the anaerobic migrating blanket reactor (AMBR) was used to treat a synthetic wastewater containing 2,4-dinitrotoluene (2,4-DNT). A Box-Wilson statistical experiment design was used to determine the effects of 2,4-DNT and the hydraulic retention times (HRTs) on 2,4-DNT and COD removal efficiencies in the AMBR reactor. The 2,4-DNT concentrations in the feed (0-280 mg/L) and the HRT (0.5-10 days) were considered as the independent variables while the 2,4-DNT and chemical oxygen demand (COD) removal efficiencies, total and methane gas productions, methane gas percentage, pH, total volatile fatty acid (TVFA) and total volatile fatty acid/bicarbonate alkalinity (TVFA/Bic.Alk.) ratio were considered as the objective functions in the Box-Wilson statistical experiment design in the AMBR. The predicted data for the parameters given above were determined from the response functions by regression analysis of the experimental data and exhibited excellent agreement with the experimental results. The optimum HRT which gave the maximum COD (97.00%) and 2,4-DNT removal (99.90%) efficiencies was between 5 and 10 days at influent 2,4-DNT concentrations 1-280 mg/L in the AMBR. The aerobic CSTR was used for removals of residual COD remaining from the AMBR, and for metabolites of 2,4-DNT. The maximum COD removal efficiency was 99% at an HRT of 1.89 days at a 2,4-DNT concentration of 239 mg/L in the aerobic CSTR. It was found that 280 mg/L 2,4-DNT transformed to 2,4-diaminotoluene (2,4-DAT) via 2-amino-4-nitrotoluene (2-A-4-NT) and 4-amino-2-nitrotoluene (4-A-2-NT) in the AMBR. The maximum 2,4-DAT removal was 82% at an HRT of 8.61 days in the aerobic CSTR. The maximum total COD and 2,4-DNT removal efficiencies were 99.00% and 99.99%, respectively, at an influent 2,4-DNT concentration of 239 mg/L and at 1.89 days of HRT in the sequential AMBR/CSTR. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Arsenic removal in a sulfidogenic fixed-bed column bioreactor

    Energy Technology Data Exchange (ETDEWEB)

    Altun, Muslum, E-mail: muslumaltun@hotmail.com [Hacettepe University, Department of Chemistry, Beytepe, Ankara (Turkey); Sahinkaya, Erkan [Istanbul Medeniyet University, Bioengineering Department, Goztepe, Istanbul (Turkey); Durukan, Ilknur; Bektas, Sema [Hacettepe University, Department of Chemistry, Beytepe, Ankara (Turkey); Komnitsas, Kostas [Technical University of Crete, Department of Mineral Resources Engineering, Chania (Greece)

    2014-03-01

    Highlights: • Sulfidogenic treatment of As-containing AMD was investigated. • High rate simultaneous removal of As and Fe was achieved. • As was removed without adding alkalinity or adjusting pH. • As and Fe removal mechanisms were elucidated. - Abstract: In the present study, the bioremoval of arsenic from synthetic acidic wastewater containing arsenate (As{sup 5+}) (0.5–20 mg/L), ferrous iron (Fe{sup 2+}) (100–200 mg/L) and sulfate (2000 mg/L) was investigated in an ethanol fed (780–1560 mg/L chemical oxygen demand (COD)) anaerobic up-flow fixed bed column bioreactor at constant hydraulic retention time (HRT) of 9.6 h. Arsenic removal efficiency was low and averaged 8% in case iron was not supplemented to the synthetic wastewater. Neutral to slightly alkaline pH and high sulfide concentration in the bioreactor retarded the precipitation of arsenic. Addition of 100 mg/L Fe{sup 2+} increased arsenic removal efficiency to 63%. Further increase of influent Fe{sup 2+} concentration to 200 mg/L improved arsenic removal to 85%. Decrease of influent COD concentration to its half, 780 mg/L, resulted in further increase of As removal to 96% when Fe{sup 2+} and As{sup 5+} concentrations remained at 200 mg/L and 20 mg/L, respectively. As a result of the sulfidogenic activity in the bioreactor the effluent pH and alkalinity concentration averaged 7.4 ± 0.2 and 1736 ± 239 mg CaCO{sub 3}/L respectively. Electron flow from ethanol to sulfate averaged 72 ± 10%. X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) analyses were carried out to identify the nature of the precipitate generated by sulfate reducing bacteria (SRB) activity. Precipitation of arsenic in the form of As{sub 2}S{sub 3} (orpiment) and co-precipitation with ferrous sulfide (FeS), pyrite (FeS{sub 2}) or arsenopyrite (FeAsS) were the main arsenic removal mechanisms.

  19. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    Science.gov (United States)

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  20. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-01-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study. PMID:6639023

  1. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-09-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study.

  2. How cod shapes its world

    NARCIS (Netherlands)

    van Leeuwen, A.; de Roos, A.M.; Persson, L.

    2008-01-01

    Cod stocks in the North West Atlantic and the Baltic Sea have shown similar dynamics in recent decades with a rapid decline in abundance and a lack of stock recovery following a period of large biomass. We explore whether the lack of recovery can be ascribed to an emergent Allee effect, which is a

  3. Removal performance and water quality analysis of paper machine white water in a full-scale wastewater treatment plant.

    Science.gov (United States)

    Shi, Shuai; Wang, Can; Fang, Shuai; Jia, Minghao; Li, Xiaoguang

    2017-06-01

    Paper machine white water is generally characterized as a high concentration of suspended solids and organic matters. A combined physicochemical-biological and filtration process was used in the study for removing pollutants in the wastewater. The removal efficiency of the pollutant in physicochemical and biological process was evaluated, respectively. Furthermore, advanced technology was used to analyse the water quality before and after the process treatment. Experimental results showed that the removal efficiency of suspend solids (SS) of the system was above 99%, while the physicochemical treatment in the forepart of the system had achieved about 97%. The removal efficiency of chemical oxygen demand (COD) and colour had the similar trend after physicochemical treatment and were corresponding to the proportion of suspended and the near-colloidal organic matter in the wastewater. After biological treatment, the removal efficiency of COD and colour achieved were about 97% and 90%, respectively. Furthermore, molecular weight (MW) distribution analysis showed that after treatment low MW molecules (analysis showed that most humic-like substances were effectively removed during the treatment. The analyses of gas chromatography/mass spectrometry showed that the composition of organic matter in the wastewater was not complicated. Methylsiloxanes were the typical organic components in the raw wastewater and most of them were removed after treatment.

  4. Exophiala angulospora causes systemic inflammation in atlantic cod Gadus morhua.

    Science.gov (United States)

    Gjessing, Mona Cecilie; Davey, Marie; Kvellestad, Agnar; Vrålstad, Trude

    2011-10-06

    Species of Exophiala are opportunistic fungal pathogens that may infect a broad range of warm- and cold-blooded animals, including salmonids and Atlantic cod. In the present study, we observed abnormal swimming behaviour and skin pigmentation and increased mortality in cod kept in an indoor tank. Necropsy revealed foci of different sizes with a greyish to brownish colour in internal organs of diseased fish. The foci consisted of ramifying darkly pigmented fungal hyphae surrounded by distinct layers of inflammatory cells, including macrophage-like cells. In the inner layer with many hyphae, the macrophage-like cells were dead. We observed no apparent restriction of fungal growth by the inflammatory response. A darkly pigmented fungus was repeatedly isolated in pure culture from foci of diseased fish and identified as Exophiala angulospora using morphological and molecular characters. This species has not been previously reported to cause disease in cod, but has been reported as an opportunistic pathogen of both marine and freshwater fish. Based on the morphology and sequence analysis presented here, we conclude that E. angulospora caused the observed chronic multifocal inflammation in internal organs of cod, leading to severe disease and mortality.

  5. Sensory characteristics of different cod products related to consumer preferences and attitudes

    DEFF Research Database (Denmark)

    Sveinsdottir, K.; Martinsdottir, E.; Green-Petersen, Ditte

    2009-01-01

    countries tasted and scored the cod products on a 9-point hedonic scale. In addition information on the consumers attitudes, motives/barriers and fish purchase behaviour was collected. The aim was to investigate how sensory quality corresponded to consumers liking of different cod products and to study...... to fish consumption, attitudes and preferences of the eight cod products. However, it was demonstrated that within each country, different segments of consumers existed with different preferences, motives/barriers and demographic background. The results indicated various potential to increase fish...

  6. Simultaneous removal and evaluation of organic substrates and NH{sub 3}-N by a novel combined process in treating chemical synthesis-based pharmaceutical wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhaobo [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China); Wang, Hongcheng [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Ren, Nanqi, E-mail: rnq@hit.edu.cn [State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China); Cui, Minhua; Nie, Shukai; Hu, Dongxue [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer We research a novel combined process to treat chemical synthesis-based pharmaceutical wastewater. Black-Right-Pointing-Pointer The mechanism of amoxicillin verifies that the biodegradation, adsorption, hydrolysis and unknown mechanism were able to remove amoxicillin from wastewater. Black-Right-Pointing-Pointer In this study demonstrates that biodegradation is the major factor for removal mechanism at work for amoxicillin. Black-Right-Pointing-Pointer Mathematical statistic methods were employed to evaluate the performance of the WWTP. - Abstract: A full-scale novel combined anaerobic/micro-aerobic and two-stage aerobic biological process is used for the treatment of an actual chemical synthesis-based pharmaceutical wastewater containing amoxicillin. The anaerobic system is an up-flow anaerobic sludge blanket (UASB), the micro-aerobic system is a novel micro-aerobic hydrolysis acidification reactor (NHAR) and the two-stage aerobic process comprised cyclic activated sludge system (CASS) and biological contact oxidation tank (BCOT). The influent wastewater was high in COD, NH{sub 3}-N varying daily 4016-13,093 mg-COD L{sup -1} and 156.4-650.2 mg-NH{sub 3}-N L{sup -1}, amoxicillin varying weekly between 69.1 and 105.4 mg-amoxicillin L{sup -1}, respectively; Almost all the COD, NH{sub 3}-N, amoxicillin were removed by the biological combined system, with removal percentages 97%, 93.4% and 97.2%, respectively, leaving around 104 mg-COD L{sup -1}, 9.4 mg-NH{sub 3}-N L{sup -1} and 2.6 {+-} 0.8 mg-amoxicillin L{sup -1} in the final clarifier effluent. The performance evaluation of the wastewater treatment plant (WWTP) by mathematical statistic methods shown that at most of time effluent can meet the higher treatment discharge standard. In addition, the fate of amoxicillin in the full-scale WWTP and the amoxicillin removal rate of each different removal routes in UASB, NHAR, CASS, BCOT and final clarifier processes are investigated

  7. Removal of Penicillin G by combination of sonolysis and Photocatalytic (sonophotocatalytic) process from aqueous solution: process optimization using RSM (Response Surface Methodology).

    Science.gov (United States)

    Almasi, Ali; Dargahi, Abdollah; Mohamadi, Mitra; Biglari, Hamed; Amirian, Farhad; Raei, Mehdi

    2016-09-01

    Penicillin G (PG) is used in a variety of infectious diseases, extensively. Generally, when antibiotics are introduced into the food chain, they pose a threat to the environment and can risk health outcomes. The aim of the present study was the removal of Penicillin G from an aqueous solution through an integrated system of UV/ZnO and UV/WO 3 with Ultrasound pretreatment. In this descriptive-analytical work dealing with the removal of Penicillin G from an aqueous solution, four significant variables, contact time (60-120 min), Penicillin G concentration (50-150 mg/L), ZnO dose (200-400 mg/L), and WO 3 dose (100-200 mg/L) were investigated. Experiments were performed in a Pyrex reactor (batch, 1 Lit) with an artificial UV 100-Watt medium pressure mercury lamp, coupled with ultrasound (100 W, 40 KHz) for PG pre-treatment. Chemical Oxygen Demand (COD) was selected to follow the performance of the photo-catalytic process and sonolysis. The experiments were based on a Central Composite Design (CCD) and analyzed by Response Surface Methodology (RSM). A mathematical model of the process was designed according to the proposed degradation scheme. The results showed that the maximum removal of PG occurred in ultrasonic/UV/WO 3 in the presence of 50 mg/L WO 3 and contact time of 120 minutes. In addition, an increase in the PG concentration caused a decrease in COD removal. As the initial concentration of the catalyst increased, the COD removal also increased. The maximum COD removal (91.3%) achieved by 200 mg/L WO 3 and 400 mg/l ZnO, a contact time of 120 minutes, and an antibiotic concentration of 50 mg/L. All of the variables in the process efficiency were found to be significant (p research data supported the conclusion that the combination of advanced oxidation process of sonolysis and photocatalytic (sonophotocatalytic) were applicable and environmentally friendly processes, which preferably can be applied extensively.

  8. Impact of influent COD/N ratio on disintegration of aerobic granular sludge.

    Science.gov (United States)

    Luo, Jinghai; Hao, Tianwei; Wei, Li; Mackey, Hamish R; Lin, Ziqiao; Chen, Guang-Hao

    2014-10-01

    Disintegration of aerobic granular sludge (AGS) is a challenging issue in the long-term operation of an AGS system. Chemical oxygen demand (COD)-to-nitrogen (N) ratio (COD/N), often variable in industrial wastewaters, could be a destabilizing factor causing granule disintegration. This study investigates the impact of this ratio on AGS disintegration and identifies the key causes, through close monitoring of AGS changes in its physical and chemical characteristics, microbial community and treatment performance. For specific comparison, two lab-scale air-lift type sequencing batch reactors, one for aerobic granular and the other for flocculent sludge, were operated in parallel with three COD/N ratios (4, 2, 1) applied in the influent of each reactor. The decreased COD/N ratios of 2 and 1 strongly influenced the stability of AGS with regard to physical properties and nitrification efficiency, leading to AGS disintegration when the ratio was decreased to 1. Comparatively the flocculent sludge maintained relatively stable structure and nitrification efficiency under all tested COD/N ratios. The lowest COD/N ratio resulted in a large microbial community shift and extracellular polymeric substances (EPS) reduction in both flocculent and granular sludges. The disintegration of AGS was associated with two possible causes: 1) reduction in net tyrosine production in the EPS and 2) a major microbial community shift including reduction in filamentous bacteria leading to the collapse of granule structure. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Investigation of combined coagulation and advanced oxidation process efficiency for the removal of Clarithromycin from wastewater

    Directory of Open Access Journals (Sweden)

    ahmad reza Yazdanbakhsh

    2011-06-01

    Conclusion: In general the results of the performed tests indicated that combined coagulation and advanced oxidation process has high efficiency in removal of Claritromycin wastewater COD. But application this method in the industry should be surveyed.

  10. Sulfamethoxazole and COD increase abundance of sulfonamide resistance genes and change bacterial community structures within sequencing batch reactors.

    Science.gov (United States)

    Guo, Xueping; Pang, Weihai; Dou, Chunling; Yin, Daqiang

    2017-05-01

    The abundant microbial community in biological treatment processes in wastewater treatment plants (WWTPs) may potentially enhance the horizontal gene transfer of antibiotic resistance genes with the presence of antibiotics. A lab-scale sequencing batch reactor was designed to investigate response of sulfonamide resistance genes (sulI, sulII) and bacterial communities to various concentrations of sulfamethoxazole (SMX) and chemical oxygen demand (COD) of wastewater. The SMX concentrations (0.001 mg/L, 0.1 mg/L and 10 mg/L) decreased with treatment time and higher SMX level was more difficult to remove. The presence of SMX also significantly reduced the removal efficiency of ammonia nitrogen, affecting the normal function of WWTPs. All three concentrations of SMX raised both sulI and sulII genes with higher concentrations exhibiting greater increases. The abundance of sul genes was positive correlated with treatment time and followed the second-order reaction kinetic model. Interestingly, these two genes have rather similar activity. SulI and sulII gene abundance also performed similar response to COD. Simpson index and Shannon-Weiner index did not show changes in the microbial community diversity. However, the 16S rRNA gene cloning and sequencing results showed the bacterial community structures varied during different stages. The results demonstrated that influent antibiotics into WWTPs may facilitate selection of ARGs and affect the wastewater conventional treatment as well as the bacteria community structures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Improvement of the degradation of sulfate rich wastewater using sweetmeat waste (SMW) as nutrient supplement.

    Science.gov (United States)

    Das, Bidus Kanti; Roy, Shantonu; Dev, Subhabrata; Das, Debabrata; Bhattacharya, Jayanta

    2015-12-30

    External dosing of sweetmeat waste (SMW) dosing into exhausted upflow packed bed bioreactor (PBR) resulted in prompt reactivation of SO4(2-) removal. Different SMW concentrations in terms of chemical oxygen demand (COD)/SO4(2-) ratios (1, 2, 4 and 8) were introduced into four identical PBR where process stability was found within 3 weeks of operation. SO4(2-) removal was proportional to COD/SO4(2-) ratios up to 4 at which maximum sulfate removal (99%) was achieved at a rate of 607 mg/d. The value of COD consumption:SO4(2-)removal was much higher at ratio 4 than 8 whereas, ratio 2 was preferred over all. Net effluent acetate concentration profile and total microbial population attached to the reactor matrices were corresponding to COD/SO4(2-) ratio as 4>8>2>1. Sulfate reducing bacteria (SRB) population was found to be inversely proportional to COD/SO4(2-) ratio in which acetate oxidizing SRB and fermentative bacteria were the dominant. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Investigation of relationships between removals of tetracycline and degradation products and physicochemical parameters in municipal wastewater treatment plant.

    Science.gov (United States)

    Topal, Murat; Uslu Şenel, Gülşad; Öbek, Erdal; Arslan Topal, E Işıl

    2016-05-15

    Determination of the effect of physicochemical parameters on the removal of tetracycline (TC) and degradation products is important because of the importance of the removal of antibiotics in Wastewater Treatment Plant (WWTP). Therefore, the purpose of this study was to investigate the relationships between removals of TC and degradation products and physicochemical parameters in Municipal Wastewater Treatment Plant (MWWTP). For this aim, (i) the removals of physicochemical parameters in a MWWTP located in Elazığ city (Turkey) were determined (ii) the removals of TC and degradation products in MWWTP were determined (iii) the relationships between removals of TC and degradation products and physicochemical parameters were investigated. TC, 4-epitetracycline (ETC), 4-epianhydrotetracycline (EATC), anhydrotetracycline (ATC), and physicochemical parameters (pH, temperature, electrical conductivity (EC), suspended solids (SS), BOD5, COD, total organic carbon (TOC), NH4(+)-N, NO2(-)-N, NO3(-)-N and O-PO4(-3)) were determined. The calculation of the correlation coefficients of relationships between the physicochemical parameters and TC, EATC, ATC showed that, among the investigated parameters, EATC and SS most correlated. The removals of other physicochemical parameters were not correlated with TC, EATC and ATC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Optimization of operation conditions for the startup of aerobic granular sludge reactors biologically removing carbon, nitrogen, and phosphorous.

    Science.gov (United States)

    Lochmatter, Samuel; Holliger, Christof

    2014-08-01

    The transformation of conventional flocculent sludge to aerobic granular sludge (AGS) biologically removing carbon, nitrogen and phosphorus (COD, N, P) is still a main challenge in startup of AGS sequencing batch reactors (AGS-SBRs). On the one hand a rapid granulation is desired, on the other hand good biological nutrient removal capacities have to be maintained. So far, several operation parameters have been studied separately, which makes it difficult to compare their impacts. We investigated seven operation parameters in parallel by applying a Plackett-Burman experimental design approach with the aim to propose an optimized startup strategy. Five out of the seven tested parameters had a significant impact on the startup duration. The conditions identified to allow a rapid startup of AGS-SBRs with good nutrient removal performances were (i) alternation of high and low dissolved oxygen phases during aeration, (ii) a settling strategy avoiding too high biomass washout during the first weeks of reactor operation, (iii) adaptation of the contaminant load in the early stage of the startup in order to ensure that all soluble COD was consumed before the beginning of the aeration phase, (iv) a temperature of 20 °C, and (v) a neutral pH. Under such conditions, it took less than 30 days to produce granular sludge with high removal performances for COD, N, and P. A control run using this optimized startup strategy produced again AGS with good nutrient removal performances within four weeks and the system was stable during the additional operation period of more than 50 days. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Development of a SNP resource and a genetic linkage map for Atlantic cod (Gadus morhua

    Directory of Open Access Journals (Sweden)

    Higgins Brent

    2010-03-01

    Full Text Available Abstract Background Atlantic cod (Gadus morhua is a species with increasing economic significance for the aquaculture industry. The genetic improvement of cod will play a critical role in achieving successful large-scale aquaculture. While many microsatellite markers have been developed in cod, the number of single nucleotide polymorphisms (SNPs is currently limited. Here we report the identification of SNPs from sequence data generated by a large-scale expressed sequence tag (EST program, focusing on fish originating from Canadian waters. Results A total of 97976 ESTs were assembled to generate 13448 contigs. We detected 4753 SNPs that met our selection criteria (depth of coverage ≥ 4 reads; minor allele frequency > 25%. 3072 SNPs were selected for testing. The percentage of successful assays was 75%, with 2291 SNPs amplifying correctly. Of these, 607 (26% SNPs were monomorphic for all populations tested. In total, 64 (4% of SNPs are likely to represent duplicated genes or highly similar members of gene families, rather than alternative alleles of the same gene, since they showed a high frequency of heterozygosity. The remaining polymorphic SNPs (1620 were categorised as validated SNPs. The mean minor allele frequency of the validated loci was 0.258 (± 0.141. Of the 1514 contigs from which validated SNPs were selected, 31% have a significant blast hit. For the SNPs predicted to occur in coding regions (141, we determined that 36% (51 are non-synonymous. Many loci (1033 SNPs; 64% are polymorphic in all populations tested. However a small number of SNPs (184 that are polymorphic in the Western Atlantic were monomorphic in fish tested from three European populations. A preliminary linkage map has been constructed with 23 major linkage groups and 924 mapped SNPs. Conclusions These SNPs represent powerful tools to accelerate the genetic improvement of cod aquaculture. They have been used to build a genetic linkage map that can be applied to

  15. Treatment and remediation of a wastewater lagoon using microelectrolysis and modified DAT/IAT methods.

    Science.gov (United States)

    Wu, Qiong; Hua, Tao; Zhou, Qixing

    2011-01-01

    To examine treatment and remediation of a wastewater lagoon with poor biodegradability, a typical wastewater lagoon in Tianjin, China, was treated and remedied using microelectrolysis and modified demand aeration tank (DAT)/intermittent aeration tank (IAT) methods. After pretreatment by microelectrolysis, the removal efficiency of chemical oxygen demand (COD) was up to 64.6% and the ratio of BOC/COD in the effluent increased from 0.013 to 0.609. The removal rates of COD(Cr) and NH4(+)-N were affected by sludge backflow rate, mixed liquor suspended solids (MLSS), and hydraulic retention time (HRT) in the modified DAT/IAT reactor. The highest removal rates of COD(Cr) and NH4(+)-N were up to 78.9% and 62.6%, respectively, when the sludge backflow rate was 38.0 mL/min, the total HRT was 8.0 hr and MLSS was 4088.0 mg/L. In this case, some protozoa and metazoa were observed in activated sludge and biofilm carriers. Most of chrominance was removed by microelectrolysis treatment, while the modified DAT/IAT methods were more effective for COD(Cr) and NH4(+)-N removal.

  16. [Enhanced nitrogen and phosphorus removal of wastewater by using sludge anaerobic fermentation liquid as carbon source in a pilot-scale system].

    Science.gov (United States)

    Luo, Zhe; Zhou, Guang-Jie; Liu, Hong-Bo; Nie, Xin-Yu; Chen, Yu; Zhai, Li-Qin; Liu, He

    2015-03-01

    In order to explore the possibility of enhanced nitrogen and phosphorus removal in wastewater using sludge anaerobic fermentation liquid as external carbon source, the present study proposed an A2/O reactor system with a total effective volume of 4 660 L and real municipal wastewater for treatment. The results showed that under the conditions of the influent COD at 243.7 mg x L(-1), NH4(+) -N at 30. 9 mg x L(-1), TN at 42.9 mg'L- , TP at 2.8 mg x L(-1), the backflow ratio of nitrification liquid at 200% and recycle ratio of sludge at 100%, the addition of acetic acid into anoxic tank could enhance the removal efficiency of nitrogen and phosphorus, and the optimal influent quantity and SCOD incremental of carbon were 7 500 L x d(-1) and 50 mg L(-1), respectively. When the sludge fermentation liquid was used as external carbon source and the average effluent COD, NH4(+) -N, TN, TP removal efficiency were 81.60%, 88.91%, 64.86% and 87.61%, the effluent concentrations were 42.18, 2.77, 11.92 and 0.19 mg x L(-1), respectively, which met China's first Class (A) criteria specified in the Discharge Standard Urban Sewage Treatment Plant Pollutant (GB 18918-2002). The results of the present study demonstrated that the addition of sludge anaerobic fermented liquid as external carbon source was a feasible way to enhance the removal of nitrogen and phosphorous in municipal wastewater, providing a new feasible strategy for the reuse and recycle of sewage sludge in China.

  17. Atlantic Cod (Gadus morhua benefits from the availability of seagrass (Zostera marina nursery habitat

    Directory of Open Access Journals (Sweden)

    Richard J. Lilley

    2014-12-01

    Full Text Available The Atlantic cod (Gadus morhua is a species of significant economic and historic importance but infamous for its decline. Apart from overfishing, the causes of this decline and its subsequent lack of recovery remain largely unresolved. Indeed, the degree to which specific habitats are important for this species remains unquantified at the scale of North Atlantic. Here, the literature on the role of eelgrass meadows (Zostera marina as valuable nursery habitat for the Atlantic cod is reviewed and synthesized. Evidence is presented on relative densities of Atlantic cod in shallow water environments and in eelgrass meadows in comparison to alternative habitats. In addition, evidence pertaining to the ’viability gains’ attributed to the use of eelgrass meadows as nursery habitat (growth and survival by juvenile Atlantic cod is analyzed. Although juvenile Atlantic cod use of Z. marina is found to be facultative, when possible, available literatures indicates that they may select Z. marina as a nursery habitat where they are found in high density (average of at least 246 ha−1. From their use of Z. marina habitat the juvenile Atlantic cod receives viability benefits from it, improving their chances of reaching maturation. This paper provides strong evidence that eelgrass meadows are of significant importance to contributing to Atlantic cod stocks. Keywords: Zostera marina, Eelgrass, Gadus morhua, Fisheries, Juveniles, Nursery habitat

  18. Comparison of the Northeast Arctic cod year class strength (at the age of 3+) with the SST anomalies in main spawning ground (the Norwegian Shelf Waters) by results of analysis satellite monitoring data during last years.

    Science.gov (United States)

    Vanyushin, George

    2015-04-01

    Continuous long-term database (1998-2014) on the sea surface temperature (SST) comprising results of regional satellite monitoring (the Norwegian and the Barents seas) is used to resolve several applied problems. Authors have analyzed indirect influence the SST (the NOAA satellite data) on modern cod total stock biomass (abundance of the Northeast Arctic cod at age 3+). In this study, we went on the consideration of the relationship between the SST anomalies for March-April in the main spawning ground of the cod off the Lofoten islands in the Norwegian Shelf Waters and forecasting assessment of future cod generation success and its future abundance of 3 year old. Mean monthly SST and SST anomalies are computed for the selected area on the basis of the weekly SST maps which made by using the NOAA satellites data for the period 1998-2014. Comparison of the SST anomalies in the main spawning ground with abundance of the cod year class at age 3+ shows that survival of the cod generations was inhibited on the whole as negative (below -0,1C) well as positive SST anomalies (above +1,3C) during March and April. Finally, the results indicate that poor and low middle generations of cod at age 3+ (2002, 2004, 2010) occurred in years with negative or extremely high positive the SST anomalies in the spawning area. The SST anomalies in years which were close to normal significances provide conditions for appearance middle or strong generations of cod (2001-2003, 2005-2009, 2011-2013). So, the SST and SST anomalies (by the NOAA satellite data) characterize of increase in input of warm Atlantic waters which form numerous eddies along the main stream thus creating favorable conditions for spawning and development of the cod larvae and fry and provide them with food stock, finally direct influence on forming total stock biomass of cod and helping its population forecast. Key words: satellite monitoring of SST, the Northeast Arctic cod, spawning ground, forecast of the cod year class

  19. Externally driven mortality of cod early life stages in the central Baltic: hydrography vs. predation

    DEFF Research Database (Denmark)

    Neumann, Viola; Köster, Fritz; Schaber, Matthias

    pressure by clupeids on the early life stages of cod could have enhanced cod recruitment in recent years. The analyses are based on a large dataset of stomach content of clupeids, cod egg abundances from ichthyoplankton surveys, and hydrographic measurements. We investigate temporal and spatial variability...

  20. Monopolar Electro-Coagulation Process for Azo Dye C.I. Acid Red 18 Removal from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Ghasem Azarian

    2014-12-01

    Full Text Available The discharge of wastewaters containing an untreated dye results in aesthetic problems and an increase in gases solubility, which causes light transmission inhibition into water bodies. In spite of advantages of physicochemical and biological methods, these processes produce huge amounts of sludge, toxic by-products and require several oxidant chemicals. By contrast, electrochemical processes because of their high versatility, high efficiency and eco-friendly properties are more acceptable. In the present study, the removal of azo dye Acid Red 18 and chemical oxygen demand (COD from synthetic wastewater by monopolar (EC process was investigated and key parameters such as operating time, current density (CD, initial pH and energy, and electrode consumption were optimized. It was found that the process had a very good efficiency in the removal of both COD and color; for the iron electrode, the maximum amounts of color and COD removal were 99.5% and 59.0%, respectively. An operating time of 45 min, pH of 7 and CD of 1.2 mA/cm2 was selected as the optimized condition. The optimization of variables is extremely crucial as it results in a decrease in costs, energy and electrode consumption. Overall, the iron electrode used less energy than the aluminum electrode and was more acceptable for use in this process due to economical reasons. The findings of UV/vis spectra illustrated that the structures of this dye were removed by the process. In comparison with traditional methods such as aerobic and anaerobic systems, the EC process is a suitable alternative for the treatment of wastewaters containing dye pollutants.

  1. DEVELOPMENT OF TECHNOLOGY FOR FISH CANNED PATE'S COD-FISH SPECIES

    Directory of Open Access Journals (Sweden)

    A. A. Efremova

    2014-01-01

    Full Text Available Summary. Fish and seafood play an important role in a balanced diet. The most reliable method of preservation is the production of canned fish. Cod fishery considered traditional objects of the North Basin, which catches in recent years stored at a consistently high level. They are represented, mainly cod, haddock, pollack, whiting. Lately there has been a tendency to increase yield loaves (polar bib. The aim of this work - the development of technology - canned pate's cod fish species with the addition of plant materials. We used the adopted research microbiological, chemical and physical methods. The weight proportion of water, lipids, protein, mineral raw determined according to State standard 7636-85. Developed a technology - canned pate's cod fish species with the addition of plant materials. Optimized formulation is set to sterilization. Experimentally determined parameters of quality canned and given comprehensive assessment nutritional value of new products, organoleptic, physico-chemical, biochemical and microbiological tests showed that canned pates of Gadidae species of fish with vegetables, meet all safety requirements and are characterized, along with excellent consumer properties, high nutritional value. Based on the results of the research complex developed technical documentation for production of canned vegetables, pates of Gadidae species.

  2. Phenol removal from wastewaters by electrochemical oxidation using boron doped diamond (BDD) and Ti/Ti{sub 0.7}Ru{sub 0.3}O{sub 2} DSA Registered-Sign electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Britto-Costa, P.H.; Ruotolo, L.A.M., E-mail: pluis@ufscar.br [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil). Dept. de Engenharia Quimica

    2012-10-15

    Industrial wastewater containing non-biodegradable organic pollutants consists of highly toxic effluents whose treatment is necessary due to environmental and economical restrictions. In order to treat these effluents, an electrochemical process using a dimensionally stable anode (DSA Registered-Sign ) and boron-doped diamond (BDD) electrode was studied. The performance of these electrodes for COD removal from aqueous phenol solution was evaluated in the absence and presence of different chloride concentrations. The results showed that DSA Registered-Sign could be successfully used to remove COD when high chloride concentration (3035 mg L{sup -1}Cl{sup -}) and mild current density are employed (50 mA cm{sup -2}). On the other hand, the presence of chloride did not have the same significant effect on the COD depletion rate using BDD; however, under mild conditions (50 mA cm{sup -2}, 0.190 m s{sup -1}), the addition of 607 mg L{sup -1} Cl{sup -} improved the COD removal by approximately 52% after 8 hours of electrolysis. The effect of current density (i) and flow velocity (v) were also studied, and it was verified that they have an important role on the process performance, especially when DSA Registered-Sign is used. (author)

  3. Preferred temperature of juvenile Atlantic cod Gadus morhua with different haemoglobin genotypes at normoxia and moderate hypoxia

    DEFF Research Database (Denmark)

    Petersen, M.F.; Steffensen, J.F.

    2003-01-01

    .2+/-1.5 degrees C while HbI-1 cod preferred 15.4+/-1.1 degrees C, and this preference was significant. The effect of hypoxia (35% oxygen saturation) on the preferred temperature was also measured. Previous studies showed that the preferred temperature of fish decreases during hypoxia, and this was the case for Hb......I-1 cod, which preferred 9.8+/-1.8 degrees C during hypoxia, whereas HbI-2 cod did not show this effect. The results indicate that environmental temperature changes will lead to a distributional change in the different haemoglobin types of Atlantic cod, global warming providing an advantage for HbI-1...... cod. However, since HbI-1 cod prefer a low temperature under hypoxic conditions, a combination of increased water temperature and hypoxia could be unfavourable for Atlantic cod stocks....

  4. Research progress of on-line automatic monitoring of chemical oxygen demand (COD) of water

    Science.gov (United States)

    Cai, Youfa; Fu, Xing; Gao, Xiaolu; Li, Lianyin

    2018-02-01

    With the increasingly stricter control of pollutant emission in China, the on-line automatic monitoring of water quality is particularly urgent. The chemical oxygen demand (COD) is a comprehensive index to measure the contamination caused by organic matters, and thus it is taken as one important index of energy-saving and emission reduction in China’s “Twelve-Five” program. So far, the COD on-line automatic monitoring instrument has played an important role in the field of sewage monitoring. This paper reviews the existing methods to achieve on-line automatic monitoring of COD, and on the basis, points out the future trend of the COD on-line automatic monitoring instruments.

  5. Effects of sex, stock, and environment on the shape of known-age Atlantic cod ( Gadus morhua ) otoliths

    DEFF Research Database (Denmark)

    Cardinale, M.; Doering-Arjes, P.; Kastowsky, M.

    2004-01-01

    The effects of sex, stock, and environment on the shape of known-age Atlantic cod (Gadus morhua) otoliths from the Faroe Islands were investigated. Moreover, the feasibility of otolith shape analysis for stock identification was evaluated. The shape was described by using several normalized Fourier...... descriptors and morphometric variables. There were no consistent differences between the left and right otoliths and between sexes within different age classes, stocks, and environments. With our experimental design, we could evaluate the relative importance of genetic and environmental conditions (water...... temperature and diet regime) on otolith shape and morphometrics. Using otolith shape, cod individuals were significantly separated into Bank and Plateau stocks. Total classification success was between 79% and 85% between stocks and between 85% and 96% between environments for the different age classes...

  6. Determination of chemical oxygen demand (COD) using an alternative wet chemical method free of mercury and dichromate.

    Science.gov (United States)

    Kolb, Marit; Bahadir, Müfit; Teichgräber, Burkhard

    2017-10-01

    Worldwide, the standard methods for the determination of the important wastewater parameter chemical oxygen demand (COD) are still based on the use of the hazardous chemicals, mercury sulfate and chromium(VI). However, due to their properties they are meanwhile classified as "priority pollutants" and shall be phased out or banned in the frame of REACH (current European Chemical Law: Registration, Evaluation, Authorization and restriction of Chemicals) by the European Union. Hence, a new wet-chemical method free of mercury and chromium(VI) was developed. Manganese(III) was used as oxidant and silver nitrate for the removal of chloride ions. The quantification was performed by back titration of manganese(III) with iron(II) as done in the standard method. In order to minimize losses of organic substances during the precipitation of silver chloride, suspended and colloid organic matter had to be separated by precipitation of aluminum hydroxide in a first step. In these cases, two fractions, one of the suspended and colloid matters and a second of the dissolved organic substances, are prepared and oxidized separately. The method was tested with potassium hydrogen phthalate (KHP) as conventional COD reference substance and different types of wastewater samples. The oxidation of KHP was reproducible in a COD range of 20-500 mg/L with a mean recovery rate of 88.7% in comparison to the standard COD method (DIN 38409-41). Also in presence of 1000 mg/L chloride a recovery rate of 84.1% was reached. For a series of industrial and municipal wastewater samples a high correlation (R 2  = 0.9935) to the standard method with a mean recovery rate of 78.1% (±5.2%) was determined. Even though the results of the new method are not 100% of the standard method, its high correlation to the standard method and reproducibility offers an environmentally benign alternative method with no need to purchase new laboratory equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. CcpA and CodY Coordinate Acetate Metabolism in Streptococcus mutans.

    Science.gov (United States)

    Kim, Jeong Nam; Burne, Robert A

    2017-04-01

    In the dental caries pathogen Streptococcus mutans , phosphotransacetylase (Pta) and acetate kinase (Ack) convert pyruvate into acetate with the concomitant generation of ATP. The genes for this pathway are tightly regulated by multiple environmental and intracellular inputs, but the basis for differential expression of the genes for Pta and Ack in S. mutans had not been investigated. Here, we show that inactivation in S. mutans of ccpA or codY reduced the activity of the ackA promoter, whereas a ccpA mutant displayed elevated pta promoter activity. The interactions of CcpA with the promoter regions of both genes were observed using electrophoretic mobility shift and DNase protection assays. CodY bound to the ackA promoter region but only in the presence of branched-chain amino acids (BCAAs). DNase footprinting revealed that the upstream region of both genes contains two catabolite-responsive elements ( cre1 and cre2 ) that can be bound by CcpA. Notably, the cre2 site of ackA overlaps with a CodY-binding site. The CcpA- and CodY-binding sites in the promoter region of both genes were further defined by site-directed mutagenesis. Some differences between the reported consensus CodY binding site and the region protected by S. mutans CodY were noted. Transcription of the pta and ackA genes in the ccpA mutant strain was markedly different at low pH relative to transcription at neutral pH. Thus, CcpA and CodY are direct regulators of transcription of ackA and pta in S. mutans that optimize acetate metabolism in response to carbohydrate, amino acid availability, and environmental pH. IMPORTANCE The human dental caries pathogen Streptococcus mutans is remarkably adept at coping with extended periods of carbohydrate limitation during fasting periods. The phosphotransacetylase-acetate kinase (Pta-Ack) pathway in S. mutans modulates carbohydrate flux and fine-tunes the ability of the organisms to cope with stressors that are commonly encountered in the oral cavity. Here, we

  8. Extrusion of Contracaecum osculatum nematode larvae from the liver of cod (Gadus morhua).

    Science.gov (United States)

    Zuo, S; Barlaup, L; Mohammadkarami, A; Al-Jubury, A; Chen, D; Kania, P W; Buchmann, K

    2017-10-01

    Baltic cod livers have during recent years been found increasingly and heavily infected with third-stage larvae of Contracaecum osculatum. The infections are associated with an increasing population of grey seals which are final hosts for the parasite. Heavy worm burdens challenge utilization and safety of the fish liver products, and technological solutions for removal of worms are highly needed. We investigated the attachment of the worm larvae in liver tissue by use of histochemical techniques and found that the cod host encapsulates the worm larvae in layers of host cells (macrophages, fibroblasts) supported by enclosures of collagen and calcium. A series of incubation techniques, applying compounds targeting molecules in the capsule, were then tested for their effect to induce worm escape/release reactions. Full digestion solutions comprising pepsin, NaCl, HCl and water induced a fast escape of more than 60% of the worm larvae within 20 min and gave full release within 65 min but the liver tissue became highly dispersed. HCl alone, in concentrations of 48 and 72 mM, triggered a corresponding release of worm larvae with minor effect on liver integrity. A lower HCl concentration of 24 mM resulted in 80% release within 35 min. Water and physiological saline had no effect on worm release, and 1% pepsin in water elicited merely a weak escape reaction. In addition to the direct effect of acid on worm behaviour it is hypothesised that the acid effect on calcium carbonate in the encapsulation, with subsequent release of reaction products, may contribute to activation of C. osculatum larvae and induce escape reactions. Short-term pretreatment of infected cod liver and possibly other infected fish products, using low acid concentrations is suggested as part of a technological solution for worm clearance as low acid concentrations had limited macroscopic effect on liver integrity within 35 min.

  9. Use of COD, TOC, and Fluorescence Spectroscopy to Estimate BOD in Wastewater.

    Science.gov (United States)

    Christian, Evelyn; Batista, Jacimaria R; Gerrity, Daniel

    2017-02-01

      Common to all National Pollutant Discharge Elimination System (NPDES) permits in the United States is a limit on biochemical oxygen demand (BOD). Chemical oxygen demand (COD), total organic carbon (TOC), and fluorescence spectroscopy are also capable of quantifying organic content, although the mechanisms of quantification and the organic fractions targeted differ for each test. This study explores correlations between BOD5 and these alternate test procedures using facility influent, primary effluent, and facility effluent samples from a full-scale water resource recovery facility. Relative reductions of the water quality parameters proved to be strong indicators of their suitability as surrogates for BOD5. Suitable correlations were generally limited to the combined datasets for the three sampling locations or the facility effluent alone. COD exhibited relatively strong linear correlations with BOD5 when considering the three sample points (r = 0.985) and the facility effluent alone (r = 0.914), while TOC exhibited a suitable linear correlation with BOD5 in the facility effluent (r = 0.902). Exponential regressions proved to be useful for estimating BOD5 based on TOC or fluorescence (r > 0.95).

  10. PENGOLAHAN LINDI DENGAN OZON DAN PROSES OKSIDASI LANJUT BERBASIS OZON

    Directory of Open Access Journals (Sweden)

    Mohamad Rangga Sururi

    2014-05-01

    Full Text Available Limbah industri tekstil di area pinggir kota Surabaya mempunyai karakteristik perbandingan COD dan BOD = 5.57. Limbah jenis ini sulit untuk dibiodegradasi. Studi ini mempelajari tekonologi elektrokoagulasi untuk mengolah limbah tekstil dengan menurunkan intensitas warna, Total Suspended Solid (TSS dan Chemical Oxygen Demand (COD. Percobaan batch pada suhu kamar dilakukan untuk mempelajari pengaruh pH, jarak elektroda terhadap penurunan warna,TSS dan COD dan membandingkan biaya operasinya jika menggunakan pengolahan kimia.Effisiensi penurunan tertinggi untuk warna (91.96%,  TSS (49.17%, dan COD (29.67% terjadi pada pH awal 4.0 dan jarak elektroda 2 cm dengan  elektroda Al/Al. Waktu optimum penurunan intensitas warna dalah 10 menit. Laju penurunan COD adalah : -dC/dt = 0.0053 C +0.056 , dengan C adalah konsentrasi COD. Jumlah sludge yang dihasilkan daripengolahan elektrokoagulasi  3.4 % lebih kecil dibandingkan menggunakan bahan kimia. Biaya yang digunakan untuk pengolahan dengan elektrokoagulasi 52.35 % lebih murah dibandingkan jika menggunakan koagulasi dengan bahan kimia ( tawas. Kata kunci : elektrokoagulasi, penurunan warna, penurunan TSS, laju degradasi COD, imbah tekstil Abstract Waste water from textile industry which is located in one suburb of Surabaya city as characteristic which the ratio of COD to BOD was 5.57. This type of waste water is difficult to be biodegraded. This study investigated elektrokoagulasi technology to treat textile waste water by removing color, total suspended solid, and Chemical Oxygen Demand. Batch experiment at room temperature was carried out to study the effect of pH, electrode distance for color, TSS and COD removal. This study also tried to compare the operation cost between elektrokoagulasi and chemical processes. The best removal efficiencies by Al electrodes was 91.96 % for color, 49.17 % for TSS and 29.67 % for COD which were under initial pH 4.0 and electrodes distance 2 cm. The optimum operation

  11. PENGOLAHAN PRIMER LIMBAH TEKSTIL DENGAN ELEKTROKOAGULASI

    Directory of Open Access Journals (Sweden)

    Lieke Riadi

    2014-12-01

    Full Text Available Limbah industri tekstil di area pinggir kota Surabaya mempunyai karakteristik perbandingan COD dan BOD = 5.57. Limbah jenis ini sulit untuk dibiodegradasi. Studi ini mempelajari tekonologi elektrokoagulasi untuk mengolah limbah tekstil dengan menurunkan intensitas warna, Total Suspended Solid (TSS dan Chemical Oxygen Demand (COD. Percobaan batch pada suhu kamar dilakukan untuk mempelajari pengaruh pH, jarak elektroda terhadap penurunan warna,TSS dan COD dan membandingkan biaya operasinya jika menggunakan pengolahan kimia.Effisiensi penurunan tertinggi untuk warna (91.96%,  TSS (49.17%, dan COD (29.67% terjadi pada pH awal 4.0 dan jarak elektroda 2 cm dengan  elektroda Al/Al. Waktu optimum penurunan intensitas warna dalah 10 menit. Laju penurunan COD adalah : -dC/dt = 0.0053 C +0.056 , dengan C adalah konsentrasi COD. Jumlah sludge yang dihasilkan daripengolahan elektrokoagulasi  3.4 % lebih kecil dibandingkan menggunakan bahan kimia. Biaya yang digunakan untuk pengolahan dengan elektrokoagulasi 52.35 % lebih murah dibandingkan jika menggunakan koagulasi dengan bahan kimia ( tawas. Kata kunci : elektrokoagulasi, penurunan warna, penurunan TSS, laju degradasi COD, imbah tekstil Abstract Waste water from textile industry which is located in one suburb of Surabaya city as characteristic which the ratio of COD to BOD was 5.57. This type of waste water is difficult to be biodegraded. This study investigated elektrokoagulasi technology to treat textile waste water by removing color, total suspended solid, and Chemical Oxygen Demand. Batch experiment at room temperature was carried out to study the effect of pH, electrode distance for color, TSS and COD removal. This study also tried to compare the operation cost between elektrokoagulasi and chemical processes. The best removal efficiencies by Al electrodes was 91.96 % for color, 49.17 % for TSS and 29.67 % for COD which were under initial pH 4.0 and electrodes distance 2 cm. The optimum operation

  12. Plastic ingestion by juvenile polar cod (Boreogadus saida) in the Arctic Ocean

    NARCIS (Netherlands)

    Kühn, Susanne; Schaafsma, Fokje L.; Werven, van Bernike; Flores, Hauke; Bergmann, Melanie; Egelkraut-Holtus, Marion; Tekman, Mine B.; Franeker, van Jan A.

    2018-01-01

    One of the recently recognised stressors in Arctic ecosystems concerns plastic litter. In this study, juvenile polar cod (Boreogadus saida) were investigated for the presence of plastics in their stomachs. Polar cod is considered a key species in the Arctic ecosystem. The fish were collected both

  13. Time matters: post-surgical recovery of gastric evacuation rate in Atlantic cod

    DEFF Research Database (Denmark)

    Behrens, Jane; Gräns, Albin; Andersen, Niels Gerner

    GER was affected after surgically introducing dummies of a blood-flow biotelemetry system into the abdominal cavity of Atlantic cod. Two days post surgery the cod with implants were, together with a control group, force-fed a standardized meal and the stomach contents recovered 24h later...

  14. [Effect of Different Purple Parent Rock on Removal Rates of Nitrogen, Phosphorus and Organics in Landscape Water].

    Science.gov (United States)

    Huang, Xue-jiao; Liu, Xiao-chen; Li, Zhen-lun; Shi, Wen-hao; Yang, Shan

    2015-05-01

    In order to understand the impacts of physicochemical properties of purple parent rock on the removal rates of nitrogen, phosphorus and organics in landscape water systems, four types of purple parent rocks including Peng-lai-zhen Formation (S1) , Sha-xi-miao Formation (S2) , Fei-xian-guan Formation (S3) and Sui-ning Formation (S4) , which distribute widely in Chongqing, were selected and autoclaved, and added to unsterile landscape water collected from Chong-de Lake in Southwest University, and the landscape water only was used as control. And several indicators such as total nitrogen and phosphorus and so on of every disposal were investigated periodically. The results indicated that: (1) The highest removal rates of total nitrogen, total phosphorus and Ammonia nitrogen were observed in Sl, which were 45.1%, 62.3% and 90%, respectively; the highest removal rate of COD was 94.5% in S4; the ammonia nitrogen content in the purple parent rocks was not obviously changed before and after the experiments, which indicated that the adsorption of ammonia nitrogen on purple parent rock surface was not the main reason for the decrease of ammonia nitrogen in water. (2) Arsenate had inhibitory effect on the sulfate-reducing bacteria, while copper and magnesium had promoting effect on gram-negative bacteria. (3) The microbial diversity was positively correlated to total nitrogen in water. (4) Based on the PCA analyses of microbial community structure and environmental factors, the mineral elements released from parent rock affected the structure and composition of microbial community in the test water, and then influenced the removal rates of nitrogen, phosphorus and organics in water systems.

  15. Assessing impacts of simulated oil spills on the Northeast Arctic cod fishery.

    Science.gov (United States)

    Carroll, JoLynn; Vikebø, Frode; Howell, Daniel; Broch, Ole Jacob; Nepstad, Raymond; Augustine, Starrlight; Skeie, Geir Morten; Bast, Radovan; Juselius, Jonas

    2018-01-01

    We simulate oil spills of 1500 and 4500m 3 /day lasting 14, 45, and 90days in the spawning grounds of the commercial fish species, Northeast Arctic cod. Modeling the life history of individual fish eggs and larvae, we predict deviations from the historical pattern of recruitment to the adult population due to toxic oil exposures. Reductions in survival for pelagic stages of cod were 0-10%, up to a maximum of 43%. These reductions resulted in a decrease in adult cod biomass of <3% for most scenarios, up to a maximum of 12%. In all simulations, the adult population remained at full reproductive potential with a sufficient number of juveniles surviving to replenish the population. The diverse age distribution helps protect the adult cod population from reductions in a single year's recruitment after a major oil spill. These results provide insights to assist in managing oil spill impacts on fisheries. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. Ingestion of bacteria by cod (Gadus morhua L.) larvae. In: The propagation of cod Gadus morhua L.: an international symposium, Arendal, 14 - 17 June 1983

    OpenAIRE

    Olafsen, Jan A.

    1984-01-01

    The uptake of Rhodamine-labelled bacteria by cod larvae was demonstrated using a fluorescent microscopy technique, which allowed a quick estimate of bacterial uptake and gut clearance. Live or heat-killed bacteria, isolated from cod-eggs, were rapidly ingested by larvae at yolk-sac and older stages. A substantial uptake could be seen after 15 min exposure, and eventually the bacteria became densely packed in the digestive tract. Some morphological details in the develo...

  17. [Spatial distribution of COD and the correlations with other parameters in the northern region of Lake Taihu].

    Science.gov (United States)

    Zhang, Yun-lin; Yang, Long-yuan; Qin, Bo-qiang; Gao, Guang; Luo, Lian-cong; Zhu, Guang-wei; Liu, Ming-liang

    2008-06-01

    Spatial variation of chemical oxygen demand (COD) concentration was documented and significant correlations between COD concentration and chromophoric dissolved organic matter (CDOM) absorption, fluorescence, DOC concentration were found based on a cruise sampling in the northern region of Lake Taihu in summer including 42 samplings. The possible source of COD was also discussed using every two cruise samplings in summer and winter, respectively. The COD concentration ranged from 3.77 to 7.96 mg x L(-1) with a mean value of (5.90 +/- 1.54) mg x L(-1). The mean COD concentrations in Meiliang Bay and the central lake basin were (6.93 +/- 0.89) mg x L(-1) and (4.21 +/- 0.49) mg x L(-1) respectively. A significant spatial difference was found between Meiliang Bay and the central lake basin in COD concentration, CDOM absorption coefficient, fluorescence, DOC and phytoplankton pigment concentrations, decreasing from the river mouth to inner bay, outer bay and the central lake basin. Significant correlations between COD concentration and CDOM absorption, fluorescence, DOC concentration, suggested that COD concentration could be estimated and organic pollution could be assessed using CDOM absorption retrieved from remote sensing images. Significant and positive correlation was found between COD concentration and chlorophyll a concentration in summer. However, the correlation was weak or no correlation was found in winter. Furthermore, a significant higher COD concentration was found in summer than in winter (p summer, except for river terrestrial input.

  18. Photo-removal of sulfamethoxazole (SMX) by photolytic and photocatalytic processes in a batch reactor under UV-C radiation ({lambda}{sub max} = 254 nm)

    Energy Technology Data Exchange (ETDEWEB)

    Nasuhoglu, Deniz; Yargeau, Viviane [Department of Chemical Engineering, McGill University, 3610 University Street, Montreal, Quebec, H3A 2B2 (Canada); Berk, Dimitrios, E-mail: dimitrios.berk@mcgill.ca [Department of Chemical Engineering, McGill University, 3610 University Street, Montreal, Quebec, H3A 2B2 (Canada)

    2011-02-15

    In this study, photolytic and photocatalytic removal of the antibiotic sulfamethoxazole (SMX) under UVC radiation ({lambda} = 254 nm) was investigated. The light intensity distribution inside the batch photoreactor was characterized by azoxybenzene actinometry. The intensity of incident radiation was found to be a strong function of position inside the reactor. 12 mg L{sup -1} of SMX was completely removed within 10 min of irradiation under UVC photolysis, compared to 30 min under TiO{sub 2} photocatalysis. COD measurement was used as an indication of the mineralization efficiency of both processes and higher COD removal with photocatalysis was shown. After 6 h of reaction with photolysis and photocatalysis, 24% and 87% removal of COD was observed, respectively. Two of the intermediate photo-products were identified as sulfanilic acid and 3-amino-5-methylisoxazole by direct comparison of the HPLC chromatograms of standards to those of treated solutions. Ecotoxicity of treated and untreated solutions of SMX towards Daphnia magna was also investigated. It was found that a 3:1 ratio of sample to standard freshwater and a high initial concentration of 60 mg L{sup -1} of SMX were used to obtain reliable and reproducible results. The photo-products formed during photocatalytic and photolytic processes were shown to be generally more toxic than the parent compound.

  19. Biodegradation of COD in Household Wastewater with Aerobic Biofilm Technology by Adding Sediment Drainage Sewerage

    Science.gov (United States)

    Sumiyati, Sri; Purwanto; Sutrisno, Endro; Sudarno; Arthawidya, Jalu; Izzudin, Humam

    2018-02-01

    Household wastewater contains contaminants that harm the environment. One of the pollutants found COD. If being discharged into the environment directly, COD concentrations exceeding the existing quality standard will disrupt the ecosystem in the receiving water body. One of the technologies that can degrade COD is biofilm technology with honeycomb tube media. This research aims to analyze the decrease of COD concentration present in wastewater household with biofilm technology of honeycomb media. The reactor used in was made of glass with a thickness of 4 mm, a volume of 18 litres and operated continuously. The media used is made of a PVC pipe, cut to 3 cm in size and then glued to one another, forming a honey comb. The results showed that there has been a decrease in COD concentration of household wastewater.

  20. Anaerobic removal of the brl direct blue dye in Upflow Anaerobic Sludge Blanket (UASB with activated carbon

    Directory of Open Access Journals (Sweden)

    Christian Zavala-Rivera

    2015-07-01

    Full Text Available In this research the brl direct blue dye was used for anaerobic removal with a bacterial consortium of industrial effluents from Industrial Park Río Seco (IPRS, Arequipa, Peru; in an anaerobic reactor of UASB Upflow with activated carbon. The reactor had a capacity of 14.4 L with sludge and activated carbon of 40% of volume, with an organic load of 6 Kg COD/m3•dia and a hydraulic retention time of 1 day with an upward flow. The objective was to measure the efficiency of the anaerobic removal of coloring in a time of 28 days. The results showed an increase of 41% of the solids suspended volatile (SSV 12894 mg•L-1 up to 21546 mg•L-1 under the conditions of the experiment, with a removal of 57% of the chemical demand of oxygen (COD from 484 mg•L-1 to 122 mg•L-1 and a removal of 87% of the dye Blue direct the 69.61 brl mg•L-1 to 9 mg•L-1. Results with activated charcoal granular only, they showed a removal of 61% of the dye Blue direct 70.67 brl mg•L-1 to 27.83 mg•L-1 at 28 days.

  1. High power generation and COD removal in a microbial fuel cell operated by a novel sulfonated PES/PES blend proton exchange membrane

    International Nuclear Information System (INIS)

    Zinadini, S.; Zinatizadeh, A.A.; Rahimi, M.; Vatanpour, V.; Rahimi, Z.

    2017-01-01

    In this paper, firstly sulfonated polyethersulfone (SPES) was synthesized from polyethersulfone (PES) with sulfonation by chlorosulfonic acid as a sulfonating agent dissolved in concentrated sulfuric acid. PES/SPES blend proton exchange membranes (PEMs) were prepared at four different compositions with the non-solvent induced phase separation technique as alternative materials to Nafion membrane for application in a microbial fuel cell (MFC). The prepared PEMs were characterized by FTIR spectroscopy, AFM, SEM, contact angle, water uptake and oxygen permeability. Performances of the fabricated PEMs and commercial Nafion 117 were evaluated in a dual chamber MFC for treating of wastewater and electricity generation. Maximum generated power and current of the fabricated membranes were 58.726 mWm −2  at current density of 317.111 mAm −2 , while it was 45.512 mWm −2  at 228.673 mAm −2 for Nafion 117 at the similar experimental condition. The observed properties of low biofouling, low oxygen permeability, high power generation, high COD removal and coulombic efficiency (CE) indicated that the SPES membrane has potential to improve significantly the productivity of MFCs. - Highlights: • Sulfonated PES (SPES) was synthesized by chlorosulfonic acid in concentrated H 2 SO 4 . • PES/SPES blend proton exchange membranes (PEMs) were prepared for use in MFC. • Performance of PEMs and commercial Nafion 117 were tested to treat of wastewater. • Maximum generated power and current of SPES membrane was higher than Nafion 117.

  2. Staphylococcus aureus hyaluronidase is a CodY-regulated virulence factor.

    Science.gov (United States)

    Ibberson, Carolyn B; Jones, Crystal L; Singh, Shweta; Wise, Matthew C; Hart, Mark E; Zurawski, Daniel V; Horswill, Alexander R

    2014-10-01

    Staphylococcus aureus is a Gram-positive pathogen that causes a diverse range of bacterial infections. Invasive S. aureus strains secrete an extensive arsenal of hemolysins, immunomodulators, and exoenzymes to cause disease. Our studies have focused on the secreted enzyme hyaluronidase (HysA), which cleaves the hyaluronic acid polymer at the β-1,4 glycosidic bond. In the study described in this report, we have investigated the regulation and contribution of this enzyme to S. aureus pathogenesis. Using the Nebraska Transposon Mutant Library (NTML), we identified eight insertions that modulate extracellular levels of HysA activity. Insertions in the sigB operon, as well as in genes encoding the global regulators SarA and CodY, significantly increased HysA protein levels and activity. By altering the availability of branched-chain amino acids, we further demonstrated CodY-dependent repression of HysA activity. Additionally, through mutation of the CodY binding box upstream of hysA, the repression of HysA production was lost, suggesting that CodY is a direct repressor of hysA expression. To determine whether HysA is a virulence factor, a ΔhysA mutant of a community-associated methicillin-resistant S. aureus (CA-MRSA) USA300 strain was constructed and found to be attenuated in a neutropenic, murine model of pulmonary infection. Mice infected with this mutant strain exhibited a 4-log-unit reduction in bacterial burden in their lungs, as well as reduced lung pathology and increased levels of pulmonary hyaluronic acid, compared to mice infected with the wild-type, parent strain. Taken together, these results indicate that S. aureus hyaluronidase is a CodY-regulated virulence factor. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  3. Characteristic Strength and Treatability of a Recycled Paper Mill ...

    African Journals Online (AJOL)

    ... and is thus suitable for treatment by anaerobic process. In a UASB reactor, about 63 per cent COD removal and total biogas production rate of 0.2 l/g COD were attained at a load of 12 to 15 KgCOD/m3/day. A well-pelletized sludge was formed in the reactor over a period of 4 months. (Journal of Civil Engineering, JKUAT: ...

  4. Quali-quantitative characterization and wastewater treatment of a winery located in the mid-west of Santa Catarina state, South of Brazil.

    Science.gov (United States)

    Ortigara, A R C; Sezerino, P H; Bento, A P; Scaratti, D

    2009-01-01

    This paper analyses variations in the quali-quantitative characterization of winery wastewater, and the behavior of the treatment of these effluents. The wastewater produced is sent to two disposition systems: Point A receives the wastewater from the production area whereas Point B receives the wastewater from the area where the washing of bottles takes place. Two Aerated Submerged Biofilter (ASB) reactors (with oyster shells as support material) were built at lab scale to promote the treatment of the winery effluent. Water usage and effluent production values of the 2008 harvest season indicate that grape processing accounted for 30% of the total water usage. The median value found for the effluent at Point A was 8,260 mg COD L(-1) and at Point B 358 mg COD L(-1). The average C/N/P ratio found at Point A was 100/0.29/0.28 during the harvest and 100/0.27/0.25 during the non harvest. For ASB 1 the COD removal efficiency ranged from 56% to 90%, with the removed organic load ranging from 1.5 kg COD m(-3) d(-1) to 2.7 kg COD m(-3) d(-1), respectively. For ASB 2 the COD removal efficiency ranged from 63% to 82%, with the removed organic load ranging from 1.8 kg COD m(-3) d(-1) to 1.7 kg COD m(-3) d(-1), respectively.

  5. Restricted fish feeding reduces cod otolith opacity

    DEFF Research Database (Denmark)

    Høie, H.; Folkvord, A.; Mosegaard, Henrik

    2008-01-01

    The purpose of this work was to examine the effect of reduced feeding and constant temperature on cod otolith opacity. Three groups of juvenile cod were given restricted food rations at different times for 4 months, resulting in depressed somatic growth. Otolith opacity was measured on pictures...... in otolith opacity were found between individual fish both within groups and between groups. In two of the three groups significantly more translucent otolith material was deposited in response to reduced feeding. Our results show that variations in feeding and hence fish growth resulted in variation...... in otolith opacity, but the effect was minor compared to that of variations in ambient temperature. The combined influence of these effects, which both act on fish metabolism, are most likely controlling the seasonal opacity changes observed in wild fish. Our results help explain the variations seen in fish...

  6. Evaluation of granular anaerobic ammonium oxidation process for the disposal of pre-treated swine manure

    Directory of Open Access Journals (Sweden)

    Shou-Qing Ni

    2014-04-01

    Full Text Available With rising environmental concerns on potable water safety and eutrophication, increased media attention and tighter environmental regulations, managing animal waste in an environmentally responsible and economically feasible way can be a challenge. In this study, the possibility of using granular anammox process for ammonia removal from swine waste treatment water was investigated. A rapid decrease of NO2−–N and NH4+–N was observed during incubation with wastewater from an activated sludge deodorization reactor and anaerobic digestion-partial oxidation treatment process treating swine manure and its corresponding control artificial wastewaters. Ammonium removal dropped from 98.0 ± 0.6% to 66.9 ± 2.7% and nearly absent when the organic load in the feeding increased from 232 mg COD/L to 1160 mg COD/L and 2320 mg COD/L. The presence of organic carbon had limited effect on nitrite and total nitrogen removal. At a COD to N ratio of 0.9, COD inhibitory organic load threshold concentration was 727 mg COD/L. Mass balance indicated that denitrifiers played an important role in nitrite, nitrate and organic carbon removal. These results demonstrated that anammox system had the potential to effectively treat swine manure that can achieve high nitrogen standards at reduced costs.

  7. Total pollution effect of urban surface runoff.

    Science.gov (United States)

    Luo, Hongbing; Luo, Lin; Huang, Gu; Liu, Ping; Li, Jingxian; Hu, Sheng; Wang, Fuxiang; Xu, Rui; Huang, Xiaoxue

    2009-01-01

    For pollution research with regard to urban surface runoff, most sampling strategies to date have focused on differences in land usage. With single land-use sampling, total surface runoff pollution effect cannot be evaluated unless every land usage spot is monitored. Through a new sampling strategy known as mixed stormwater sampling for a street community at discharge outlet adjacent to river, this study assessed the total urban surface runoff pollution effect caused by a variety of land uses and the pollutants washed off from the rain pipe system in the Futian River watershed in Shenzhen City of China. The water quality monitoring indices were COD (chemical oxygen demand), TSS (total suspend solid), TP (total phosphorus), TN (total nitrogen) and BOD (biochemical oxygen demand). The sums of total pollution loads discharged into the river for the four indices of COD, TSS, TN, and TP over all seven rainfall events were very different. The mathematical model for simulating total pollution loads was established from discharge outlet mixed stormwater sampling of total pollution loads on the basis of four parameters: rainfall intensity, total land area, impervious land area, and pervious land area. In order to treat surface runoff pollution, the values of MFF30 (mass first flush ratio) and FF30 (first 30% of runoff volume) can be considered as split-flow control criteria to obtain more effective and economical design of structural BMPs (best management practices) facilities.

  8. Enhanced Nutrients Removal Using Reeds Straw as Carbon Source in a Laboratory Scale Constructed Wetland

    Directory of Open Access Journals (Sweden)

    Tong Wang

    2018-05-01

    Full Text Available The low carbon/nitrogen (C/N ratio and high nitrate content characteristics of agricultural runoff restricted the nitrogen removal in constructed wetlands (CWs. To resolve such problems, the economically- and easily-obtained Phragmites Australis (reeds litters were applied and packed in the surface layer of a surface flow CW as external carbon sources. The results demonstrated that the introduction of the reeds straw increased the C concentration as a result of their decomposition during the CW operation, which will help the denitrification in the ensuing operation of an entire 148 days. The total nitrogen (TN and Chemical Oxygen Demand (COD ( in the effluent reached the peak level of 63.2 mg/L and 83 mg/L at the fourth and the second day, respectively. Subsequently, the pollutants in the CW that were filled with straw decreased rapidly and achieved a stable removal after 13 days of operation. Moreover, the present study showed that the N removal efficiency increased with the increase of the hydraulic retention time (HRT. Under the HRT of four days, the CW presented 74.1 ± 6%, 87.4 ± 6% and 56.0 ± 6% removal for TN, NO3-, and TP, respectively.

  9. Application of contact stabilization activated sludge for enhancing biological phosphorus removal (EBPR in domestic wastewater

    Directory of Open Access Journals (Sweden)

    Ehab M. Rashed

    2014-04-01

    Full Text Available The experiment has been performed in order to investigate the effect of using contact stabilization activated sludge as an application of enhancing biological phosphorous removal (EBPR by using contact tank as a phosphorus uptake zone and using thickening tank as a phosphorus release zone. The study involved the construction of a pilot plant which was setup in Quhafa waste water treatment plant (WWTP that included contact, final sedimentation, stabilization and thickening tanks, respectively with two returns sludge in this system one of them to contact tank and another to stabilization tank. Then observation of the uptake and release of total phosphorus by achievement through two batch test using sludge samples from thickener and final sedimentations. Results showed the removal efficiencies of COD, BOD and TP for this pilot plant with the range of 94%, 85.44% and 80.54%, respectively. On the other hand the results of batch tests showed that the reason of high ability of phosphorus removal for this pilot plant related to the high performance of microorganisms for phosphorus accumulating. Finally the mechanism of this pilot plant depends on the removal of the phosphorus from the domestic waste water as a concentrated TP solution from the supernatant above the thickening zone not through waste sludge like traditional systems.

  10. First-order hydrothermal oxidation kinetics of digested sludge compared with raw sludge.

    Science.gov (United States)

    Shanableh, A; Imteaz, M

    2008-09-01

    This article presents an assessment of the first-order hydrothermal oxidation kinetics of a selected digested sludge at subcritical ( 374 degrees C) temperatures in the range of 250-460 degrees C. Furthermore, the results were compared with reported oxidation kinetics of raw sludge treated under identical experimental conditions. In the assessment, oxidation was considered to proceed in two steps: (1) decomposition of the particulate, or non-filterable, chemical oxygen demand (PCOD); followed by (2) ultimate oxidation and removal of the total, particulate and soluble, COD. The accumulation and removal of soluble COD (SCOD) was determined from the difference between the rates of sludge decomposition and ultimate oxidation. Using results from batch and continuous-flow hydrothermal treatment experiments, the reacting organic ingredients were separated into groups according to the ease or difficulty at which they were decomposed or removed, with Arrhenius-type activation energy levels assigned to the different groups. The analysis confirmed that within the treatment range of 75% to more than 97% COD removal, the oxidation kinetics of the digested and raw sludges were nearly identical despite differences in the proportions of their original organic ingredients. The original organic ingredients were mostly removed above 75% COD removal, and the oxidation kinetics appeared to be dominated by the removal of acetic acid, an intermediate by-product which constituted 50% to more than 80% of the remaining COD. Furthermore, the oxidation kinetics of both sludge types were consistent with reported first-order oxidation kinetics of pure acetic acid solutions. The resulting kinetic models adequately represented hydrothermal oxidation of digested sludge, in terms of COD and PCOD removals, as well as accumulation and removal of the soluble SCOD.

  11. External Carbon Source Addition as a Means to Control an Activated Sludge Nutrient Removal Process

    DEFF Research Database (Denmark)

    Isaacs, Steven Howard; Henze, Mogens; Søeberg, Henrik

    1994-01-01

    In alternating type activated sludge nutrient removal processes, the denitrification rate can be limited by the availability of readily-degradable carbon substrate. A control strategy is proposed by which an easily metabolizable COD source is added directly to that point in the process at which d...

  12. Municipal wastewater treatment for effective removal of organic matter and nitrogen

    International Nuclear Information System (INIS)

    Grebenevich, E.V.; Zaletova, N.A.; Terentieva, N.A.

    1987-01-01

    The organic matter, as well as nitrogen and phosphorus, are nutrient substances. Their excess concentrations in water receiving bodies lead to eutrophication, moreover, the nitrogen content in water bodies is standardized according the sanitary-toxicological criterion of harmfulness: NH 4 + -N ≤0,39-2,0 mgl - , NO 3 -N ≤9,1-10 mgl - . The municipal wastewater contain, usually, organic matter estimated by BOD 150-200 mgl - , and COD 300-400 mgl - , the nitrogen compounds 50-60 mgl - , and NH 4 + -N 20-25 mgl - . NO x -N are practically absent. Their presence indicated on discharge of industrial wastewater. The total phosphorus is present in the concentration of 15 mgl - , PO 4 - - P 5-8 mgl - . Activated sludge process has been most widely used in the USSR for municipal wastewater treatment. The activated sludge is biocenoses of heterotrophic and auto trophic microorganisms. They consume nutrient matters, transferring pollution of wastewater by means of enzyme systems in acceptable forms. C, N and P-containing matters are removed from wastewater by biological intake for cell synthesis. Moreover C- containing matters are removed by oxidation to CO 2 and H 2 O. P-containing compounds under definite conditions associate with solid fraction of activated sludge and thus simultaneously removed from wastewater. The removal of nitrogen in addition to biosynthesis is carried out only in the denitrification process, when oxygen of NO x -N is used for oxidation of organic matter and produced gaseous nitrogen escapes into the atmosphere

  13. [Total pollution features of urban runoff outlet for urban river].

    Science.gov (United States)

    Luo, Hong-Bing; Luo, Lin; Huang, Gu; He, Qiang; Liu, Ping

    2009-11-01

    The urban stormwater runoff discharged to urban river, especially to rainfall source river, cannot be ignored. In this study, the Futian River watershed in Shenzhen city in a typical southern city of China is taken as the research object. In order to guide the pollution control for urban river, the eighteen rainfall events were monitored, and the total pollution features of the urban runoff outlet for this urban river were analyzed and discussed by using the process of pollutographs, the identifying to first flush, event mean concentration (EMC), etc. Results show that the concentrations of COD, SS, TN, TP and BOD5 are ten times more than the grade V of the environmental quality standards for surface water during the runoff time; the pollution caused by heavy metals (Cr, Ge, Cu, Hg and As) in runoff at a typical rainfall event is serious; the average and range of pollutant concentration at this runoff outlet in study area are evidently higher than at Shapingba in Chongqing city of China and at Silerwood in Canada, but are lower than at Shilipu in Wuhan city of China. The first flushes of COD, SS, BOD5, especially COD and SS, are evident, but the TN and TP are not. The average EMC of COD, TN, TP and BOD5 are 224.14, 571.15, 5.223, 2.04, 143.5 mg/L, respectively. To some extent, the EMC of COD is about two times of the value of the near cities, Macao and Zhuhai. The EMC of TN and TP are obviously higher than Beijing, Guangzhou and Shanghai. To compared with foreign counties, the EMC of the study area in Shenzhen is obviously much higher than the cities of Korean, USA and Canada. So the total pollution caused by the urban surface runoff in study area is serious and necessary to be treated.

  14. Biological nutrient removal and molecular biological characteristics in an anaerobic-multistage anaerobic/oxic (A-MAO) process to treat municipal wastewater.

    Science.gov (United States)

    Huang, Xiao; Dong, Wenyi; Wang, Hongjie; Jiang, Shilong

    2017-10-01

    This study aimed to present an anaerobic-multistage anaerobic/oxic (A-MAO) process to treat municipal wastewater. The average COD, NH 4 + -N, TN, and TP removal efficiency were 91.81%, 96.26%, 83.73% and 94.49%, respectively. Temperature plunge and C/N decrease have a certain impact on the modified process. Characteristics of microbial community, function microorganism, and correlation of microbial community with environmental variables in five compartments were carried out by Illumina Miseq high-throughput sequencing. The differences of microbial community were observed and Blastocatella, Flavobacterium and Pseudomonas were the dominant genus. Nitrosomonas and Nitrospira occupied a dominant position in AOB and NOB, respectively. Rhodospirillaceae and Rhodocyclaceae owned a considerable proportion in phosphorus removal bacteria. DO and COD played significant roles on affecting the microbial components. The A-MAO process in this study demonstrated a high potential for nutrient removal from municipal wastewater. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Certification of methylmercury in cod fish tissue certified reference material by species-specific isotope dilution mass spectrometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Kazumi; Kuroiwa, Takayoshi; Narukawa, Tomohiro; Yarita, Takashi; Takatsu, Akiko; Okamoto, Kensaku; Chiba, Koichi [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Environmental Standard Section, Tsukuba, Ibaraki (Japan)

    2008-07-15

    A new cod fish tissue certified reference material, NMIJ CRM 7402-a, for methylmercury analysis was certified by the National Metrological Institute of Japan in the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Cod fish was collected from the sea close to Japan. The cod muscle was powdered by freeze-pulverization and was placed into 600 glass bottles (10 g each), which were sterilized with {gamma}-ray irradiation. The certification was carried out using species-specific isotope dilution gas chromatography inductively coupled plasma mass spectrometry (SSID-GC-ICPMS), where {sup 202}Hg-enriched methylmercury (MeHg) was used as the spike compound. In order to avoid any possible analytical biases caused by nonquantitative extraction, degradation and/or formation of MeHg in sample preparations, two different extraction methods (KOH/methanol and HCl/methanol extractions) were performed, and one of these extraction methods utilized two different derivatization methods (ethylation and phenylation). A double ID method was adopted to minimize the uncertainty arising from the analyses. In order to ensure not only the reliability of the analytical results but also traceability to SI units, the standard solution of MeHg used for the reverse-ID was prepared from high-purity MeHg chloride and was carefully assayed as follows: the total mercury was determined by ID-ICPMS following aqua regia digestion, and the ratio of Hg as MeHg to the total Hg content was estimated by GC-ICPMS. The certified value given for MeHg is 0.58 {+-} 0.02 mg kg{sup -1} as Hg. (orig.)

  16. Performance of CSTR-EGSB-SBR system for treating sulfate-rich cellulosic ethanol wastewater and microbial community analysis.

    Science.gov (United States)

    Shan, Lili; Zhang, Zhaohan; Yu, Yanling; Ambuchi, John Justo; Feng, Yujie

    2017-06-01

    Performance and microbial community composition were evaluated in a two-phase anaerobic and aerobic system treating sulfate-rich cellulosic ethanol wastewater (CEW). The system was operated at five different chemical oxygen demand (COD)/SO 4 2- ratios (63.8, 26.3, 17.8, 13.7, and 10.7). Stable performance was obtained for total COD removal efficiency (94.5%), sulfate removal (89.3%), and methane production rate (11.5 L/day) at an organic loading rate of 32.4 kg COD/(m 3 ·day). The acidogenic reactor made a positive contribution to net VFAs production (2318.1 mg/L) and sulfate removal (60.9%). Acidogenic bacteria (Megasphaera, Parabacteroides, unclassified Ruminococcaceae spp., and Prevotella) and sulfate-reducing bacteria (Butyrivibrio, Megasphaera) were rich in the acidogenic reactor. In the methanogenic reactor, high diversity of microorganisms corresponded with a COD removal contribution of 83.2%. Moreover, methanogens (Methanosaeta) were predominant, suggesting that these organisms played an important role in the acetotrophic methanogenesis pathway. The dominant aerobic bacteria (Truepera) appeared to have been responsible for the COD removal of the SBR. These results indicate that dividing the sulfate reduction process could effectively minimize sulfide toxicity, which is important for the successful operation of system treating sulfate-rich CEW.

  17. Removal of selected emerging PPCP compounds using greater duckweed (Spirodela polyrhiza) based lab-scale free water constructed wetland.

    Science.gov (United States)

    Li, Jianan; Zhou, Qizhi; Campos, Luiza C

    2017-12-01

    Greater duckweed (Spirodela polyrhiza) based lab-scale free water constructed wetland (CW) was employed for removing four emerging pharmaceuticals and personal care products (PPCPs) (i.e. DEET, paracetamol, caffeine and triclosan). Orthogonal design was used to test the effect of light intensity, aeration, E.coli abundance and plant biomass on the target compounds. Synthetic wastewater contaminated with the target compounds at concentration of 25 μg/L was prepared, and both batch and continuous flow experiments were conducted. Up to 100% removals were achieved for paracetamol (PAR), caffeine (CAF) and tricolsan (TCS) while the highest removal for DEET was 32.2% in batch tests. Based on orthogonal Duncan analysis, high light intensity (240 μmolmm -2 s -1 ), full aeration, high plant biomass (1.00 kg/m 2 ) and high E.coli abundance (1.0 × 10 6  CFU/100 mL) favoured elimination of the PPCPs. Batch verification test achieved removals of 17.1%, 98.8%, 96.4% and 95.4% for DEET, PAR, CAF and TCS respectively. Continuous flow tests with CW only and CW followed by stabilization tank (CW-ST) were carried out. Final removals of the PPCP contaminants were 32.6%, 97.7%, 98.0% and 100% for DEET, PAR, CAF and TCS, respectively, by CW system alone, while 43.3%, 97.5%, 98.2% and 100%, respectively, were achieved by CW-ST system. By adding the ST tank, PPCP concentrations decreased significantly faster (p < 0.05) compared with continuous flow CW alone. In addition, after removing aerators during continuous flow CW experiments, the treatment systems presented good stability for the PPCP removals. CW-ST showed better chemical oxygen demand (COD) and total organic carbon (TOC) removals (89.3%, 91.2%, respectively) than CW only (79.4%, 85.2%, respectively). However, poor DEET removal (<50%) and high E.coli abundance (up to 1.7 log increase) in the final treated water indicated further treatment processes may be required. Statistical analysis showed significant correlations

  18. Tertiary treatment of textile wastewater with combined media biological aerated filter (CMBAF) at different hydraulic loadings and dissolved oxygen concentrations

    International Nuclear Information System (INIS)

    Liu Fang; Zhao Chaocheng; Zhao Dongfeng; Liu Guohua

    2008-01-01

    An up-flow biological aerated filter packed with two layers media was employed for tertiary treatment of textile wastewater secondary effluent. Under steady state conditions, good performance of the reactor was achieved and the average COD, NH 4 + -N and total nitrogen (TN) in the effluent were 31, 2 and 8 mg/L, respectively. For a fixed dissolved oxygen (DO) concentration, an increase of hydraulic loading resulted in a decrease in substrate removal. With the increase of hydraulic loadings from 0.13 to 0.78 m 3 /(m 2 h), the removal efficiencies of COD, NH 4 + -N and TN all decreased, which dropped from 52 to 38%, from 90 to 68% and from 45 to 33%, respectively. In addition, the results also confirmed that the increase of COD and NH 4 + -N removal efficiencies resulted from the increase of DO concentrations, but this variation trend was not observed for TN removal. With the increase of DO concentrations from 2.4 to 6.1 mg/L, the removal efficiencies of COD and NH 4 + -N were 39-53% and 64-88%, whenas TN removal efficiencies increased from 39 to 42% and then dropped to 35%

  19. Practical application of COD measurement in welded assemblies

    International Nuclear Information System (INIS)

    Beghe, S.

    1975-01-01

    Measurement of the COD makes it possible to evaluate sensitivity to brittle fracture initiation. This technique is ideal for welded structures, owing to the types of defect likely to affect them, and the magnitude of the residual stresses introduced. Moreover, the COD concept, based on thickness and temperature experiments on materials, enables evaluation of the critical defect size in these structures. However, its application to welded joints encounters certain problems. The presence of fatigue cracks in the molten zone of a welded joint is frequently disturbed by the residual stresses caused by welding. An additional difficulty is created by the problem of stable growth of the crack during the bending test. This discussion covers all these matters and suggests some solutions [fr

  20. Physical-chemical and operational performance of an anaerobic baffled reactor (ABR treating swine wastewater - 10.4025/actascitechnol.v32i4.7203

    Directory of Open Access Journals (Sweden)

    Erlon Lopes Pereira

    2010-12-01

    Full Text Available Since hog raising concentrates a huge amount of swine manure in small areas, it is considered by the environmental government organizations to be one of the most potentially pollutant activities. Therefore the main objective of this research was to evaluate by operational criteria and removal efficiency, the performance of a Anaerobic Baffled Reactor (ABR, working as a biological pre-treatment of swine culture effluents. The physical-chemical analyses carried out were: total COD, BOD5, total solids (TS, fix (TFS and volatiles (TVS, temperature, pH, total Kjeldahl nitrogen, phosphorus, total acidity and alkalinity. The ABR unit worked with an average efficiency of 65.2 and 76.2%, respectively, concerning total COD and BOD5, with a hydraulic retention time (HRT about 15 hours. The results for volumetric organic loading rate (VOLR, organic loading rate (OLR and hydraulic loading rate (HLR were: 4.46 kg BOD m-3 day-1; 1.81 kg BOD5 kg TVS-1 day-1 and 1.57 m3 m-3 day-1, respectively. The average efficiency of the whole treatment system for total COD and BOD5 removal were 66.5 and 77.8%, showing an adequate performance in removing the organic matter from swine wastewater.

  1. Nitrogen removal on recycling water process of wastewater treatment plant effluent using subsurface horizontal wetland with continuous feed

    Science.gov (United States)

    Tazkiaturrizki, T.; Soewondo, P.; Handajani, M.

    2018-01-01

    Recycling water is a generic term for water reclamation and reuse to solve the scarcity of water. Constructed wetlands have been recognized as providing many benefits for wastewater treatment including water supply and control by recycling water. This research aims to find the best condition to significantly remove nitrogen using constructed wetland for recycling water of Bojongsoang Waste Water Treatment Plan (WWTP) effluent. Using media of soil, sand, gravel, and vegetation (Typha latifolia and Scirpus grossus) with an aeration system, BOD and COD parameters have been remarkably reduced. On the contrary, the removal efficiency for nitrogen is only between 50-60%. Modifications were then conducted by three step of treatment, i.e., Step I is to remove BOD/COD using Typha latifolia with an aeration system, Step II is todecrease nitrogen using Scirpus grossus with/without aeration, and Step III isto complete the nitrogen removal with denitrification process by Glycine max without aeration. Results of the research show that the nitrogen removal has been successfully increased to a high efficiency between 80-99%. The combination of aeration system and vegetation greatly affects the nitrogen removal. The vegetation acts as the organic nitrogen consumer (plant uptake) for amino acids, nitrate, and ammonium as nutrition, as well as theoxygen supplier to the roots so that aerobic microsites are formed for ammonification microorganisms.

  2. CodY Promotes Sporulation and Enterotoxin Production by Clostridium perfringens Type A Strain SM101.

    Science.gov (United States)

    Li, Jihong; Freedman, John C; Evans, Daniel R; McClane, Bruce A

    2017-03-01

    Clostridium perfringens type D strains cause enterotoxemia and enteritis in livestock via epsilon toxin production. In type D strain CN3718, CodY was previously shown to increase the level of epsilon toxin production and repress sporulation. C. perfringens type A strains producing C. perfringens enterotoxin (CPE) cause human food poisoning and antibiotic-associated diarrhea. Sporulation is critical for C. perfringens type A food poisoning since spores contribute to transmission and resistance in the harsh food environment and sporulation is essential for CPE production. Therefore, the current study asked whether CodY also regulates sporulation and CPE production in SM101, a derivative of C. perfringens type A food-poisoning strain NCTC8798. An isogenic codY -null mutant of SM101 showed decreased levels of spore formation, along with lower levels of CPE production. A complemented strain recovered wild-type levels of both sporulation and CPE production. When this result was coupled with the earlier results obtained with CN3718, it became apparent that CodY regulation of sporulation varies among different C. perfringens strains. Results from quantitative reverse transcriptase PCR analysis clearly demonstrated that, during sporulation, codY transcript levels remained high in SM101 but rapidly declined in CN3718. In addition, abrB gene expression patterns varied significantly between codY -null mutants of SM101 and CN3718. Compared to the levels in their wild-type parents, the level of abrB gene expression decreased in the CN3718 codY -null mutant strain but significantly increased in the SM101 codY -null mutant strain, demonstrating CodY-dependent regulation differences in abrB expression between these two strains. This difference appears to be important since overexpression of the abrB gene in SM101 reduced the levels of sporulation and enterotoxin production, supporting the involvement of AbrB repression in regulating C. perfringens sporulation. Copyright © 2017

  3. Applying fermentation liquid of food waste as carbon source to a pilot-scale anoxic/oxic-membrane bioreactor for enhancing nitrogen removal: Microbial communities and membrane fouling behaviour.

    Science.gov (United States)

    Tang, Jialing; Wang, Xiaochang C; Hu, Yisong; Ngo, Huu Hao; Li, Yuyou; Zhang, Yongmei

    2017-07-01

    Fermentation liquid of food waste (FLFW) was applied as an external carbon source in a pilot-scale anoxic/oxic-membrane bioreactor (A/O-MBR) system to enhance nitrogen removal for treating low COD/TN ratio domestic wastewater. Results showed that, with the FLFW addition, total nitrogen removal increased from lower than 20% to 44-67% during the 150days of operation. The bacterial metabolic activities were obviously enhanced, and the significant change in microbial community structure promoted pollutants removal and favored membrane fouling mitigation. By monitoring transmembrane pressure and characterizing typical membrane foulants, such as extracellular polymeric substances (EPS), dissolved organic matter (DOM), and inorganics and biopolymers in the cake layer, it was confirmed that FLFW addition did not bring about any additional accumulation of membrane foulants, acceleration of fouling rate, or obvious irreversible membrane fouling in the whole operation period. Therefore, FLFW is a promising alternative carbon source to enhance nitrogen removal for the A/O-MBR system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. The Northeast Greenland Shelf as a Potential Habitat for the Northeast Arctic Cod

    Directory of Open Access Journals (Sweden)

    Kjersti O. Strand

    2017-09-01

    Full Text Available Observations (1978–1991 of distributions of pelagic juvenile Northeast Arctic cod (Gadus morhua L. show that up to 1/3 of the year class are dispersed off the continental shelf and into the deep Norwegian Sea while on the way from the spring-spawning areas along the Norwegian coast to the autumn-settlement areas in the Barents Sea. The fate of this variable fraction of pelagic juveniles off-shelf has been an open question ever since Johan Hjort's (1914 seminal work. We have examined both the mechanisms causing offspring off-shelf transport, and their subsequent destiny using an individual-based biophysical model applied to quantify growth and dispersal. Our results show, consistently with the observations, that total off-shelf transport is highly variable between years and may be up to 27.4%. Offspring from spawning grounds around Lofoten have a higher chance of being displaced off the shelf. The off-shelf transport is dominated by episodic events where frequencies and dates vary between years. Northeasterly wind conditions over a 3–7-day period prior to the off-shelf events are a good proxy for dispersal of offspring off the shelf. Offspring transported into the open ocean are on average carried along three following routes: back onto the adjacent eastern shelves and into the Barents Sea (36.9%, recirculating within the Lofoten Basin (60.7%, or drifting northwest to the northeast Greenland shelf (2.4%. For the latter fraction the transport may exceed 12% depending on year. Recent investigations have discovered distributions of young cod on the northeast Greenland shelf indicating that conditions may support survival for Northeast Arctic cod offspring.

  5. Optimization of Fenton oxidation for the removal of methyl parathion in aqueous solution

    Directory of Open Access Journals (Sweden)

    Roli Saini

    2016-09-01

    Full Text Available In the present study, for the treatment of methyl parathion, Fenton oxidation is adopted. The aims of this study were (a to assess the removal efficiency in terms of chemical oxygen demand (COD, (b to scrutinize the influence of different parameters: initial pH, concentrations of H2O2 and Fe2+ and, (c response surface methodology (RSM was used to design the Fenton process. Three-level central composite design (CCD was applied in designing the experiments to observe the effects of most important operating factors. The enactment of the model was judged with the analysis of variance (ANOVA. A quadratic model was used to represent the experimental data. The predicted values and experimental values were found to be in good agreement with the (R2 = 0.9891 and Adj-R2 = 0.9877, which define the propriety of the model. The characteristic of methyl parathion bearing wastewater was concentration 30 mg/L, COD 440 mg/L, pH 6.5. Maximum removal efficiency was perceived at acidic pH value 3.

  6. Developing Baltic cod recruitment models II : Incorporation of environmental variability and species interaction

    DEFF Research Database (Denmark)

    Köster, Fritz; Hinrichsen, H.H.; St. John, Michael

    2001-01-01

    We investigate whether a process-oriented approach based on the results of field, laboratory, and modelling studies can be used to develop a stock-environment-recruitment model for Central Baltic cod (Gadus morhua). Based on exploratory statistical analysis, significant variables influencing...... cod in these areas, suggesting that key biotic and abiotic processes can be successfully incorporated into recruitment models....... survival of early life stages and varying systematically among spawning sites were incorporated into stock-recruitment models, first for major cod spawning sites and then combined for the entire Central Baltic. Variables identified included potential egg production by the spawning stock, abiotic conditions...

  7. Wastewater treatment in a hybrid activated sludge baffled reactor

    Energy Technology Data Exchange (ETDEWEB)

    Tizghadam, Mostafa [Laboratoire des Sciences de l' Eau et de l' Environnement, Universite de Limoges, ENSIL, Parc ESTER, 16 Rue Atlantis, F-87068 Limoges Cedex (France); Dagot, Christophe [Laboratoire des Sciences de l' Eau et de l' Environnement, Universite de Limoges, ENSIL, Parc ESTER, 16 Rue Atlantis, F-87068 Limoges Cedex (France)], E-mail: dagot@ensil.unilim.fr; Baudu, Michel [Laboratoire des Sciences de l' Eau et de l' Environnement, Universite de Limoges, ENSIL, Parc ESTER, 16 Rue Atlantis, F-87068 Limoges Cedex (France)

    2008-06-15

    A novel hybrid activated sludge baffled reactor (HASBR), which contained both suspended and attached-growth biomass perfect mixing cells in series, was developed by installing standing and hanging baffles and introducing plastic brushes into a conventional activated sludge (CAS) reactor. It was used for the treatment of domestic wastewater. The effects on the operational performance of developing the suspended and attached-growth biomass and reactor configuration were investigated. The change of the flow regime from complete-mix to plug-flow, and the addition of plastic brushes as a support for biofilm, resulted in considerable improvements in the COD, nitrogen removal efficiency of domestic wastewater and sludge settling properties. In steady state, approximately 98 {+-} 2% of the total COD and 98 {+-} 2% of the ammonia of the influent were removed in the HASBR, when the influent wastewater concentration was 593 {+-} 11 mg COD/L and 43 {+-} 5 mg N/L, respectively, at a HRT of 10 h. These results were 93 {+-} 3 and 6 {+-} 3% for the CAS reactor, respectively. Approximately 90 {+-} 7% of the total COD was removed in the HASBR, when the influent wastewater concentration was 654 {+-} 16 mg COD/L at a 3 h HRT, and in the organic loading rate (OLR) of 5.36 kg COD m{sup -3} day{sup -1}. The result for the CAS reactor was 60 {+-} 3%. Existing CAS plants can be upgraded by changing the reactor configuration and introducing biofilm support media into the aeration tank.

  8. THE IMPACT OF FOOD WASTE DISCHARGE INTO THE MUNICIPAL SEWERAGE ON COD CONCENTRATION IN URBAN WASTEWATER IN OLSZTYN

    Directory of Open Access Journals (Sweden)

    Wojciech Janczukowicz

    2016-05-01

    Full Text Available The operators of wastewater treatment plants in Poland have been observing an increase in the concentration of raw sewage for several years. In particular for organic substances. This is the effect of water consumption reduction, restoration of the sewerage networks, growing wealth, widespread waste of food. The most serious adverse, influencing on the municipal wastewater composition is colloid mills application in gastronomical objects and the discharge of shredded food waste to sewer. That widespread behavior has been noticed and negated, in 2010 year, by the common position of GIS and the ME. Far too late, which confirms the situation observed at the Olsztyn wastewater treatment plant, where the biggest increase of COD values ​​was observed in 2008–2010. The average concentration of COD of sewage in the period 2011–2014 was almost twice higher than in 1996, real PE is close to the design value, despite the fact that the hydraulic load of the object slightly exceeded 50% of design value. Removing such large organic pollutant loads generates high costs, that could be avoided by reasonable food waste management.

  9. Treatment of Palm Oil Mill Effluent (POME) by Using Electrocoagulation as an Alternative Method

    International Nuclear Information System (INIS)

    Suzana Che Sayuti; Abdul Aziz Mohd Azoddein

    2015-01-01

    The treatment of palm oil mill effluent (POME) is a crucial stage to prevent from environmental pollution. An alternative method should be implemented to replace the conventional wastewater treatment method. Concentration required by the Department of Environment (DOE) is 200 mg/L for chemical oxygen demand (COD) and 100 mg/L for total suspended solid (TSS). Electrocoagulation was used to reduce the amount of COD and TSS in POME. The performance of COD and TSS removal using electrocoagulation was scrutinized. Electrocoagulation reactor was used and the optimum operating parameters were determined. The voltage parameter was manipulated in order to identify the effect on the removal efficiency of COD and TSS. The highest removal efficiency obtained were 95.71 % for COD and 99.25 % for TSS in which COD reduced from 4900 mg/L to 210 mg/L meanwhile TSS from 4000 mg/L to 30 mg/L. The final COD almost meets the requirement of DOE of 200 mg/L while TSS fulfil the requirement of 100 mg/L for standard B. The highest efficiency obtained at optimum pH 7.44, electrocoagulation time 25 min and voltage of 100 V by using aluminium electrodes. This method was found to be efficient and capable to reduce time of treatment compared to standard conventional method. (author)

  10. Performance of Electrocoagulation Process in the Removal of Total Coliform and Hetrotrophic Bacteria from Surface Water

    Directory of Open Access Journals (Sweden)

    Jamshid Derayat

    2015-03-01

    Full Text Available Electrocoagulation is an electrochemical method for the treatment of water and wastewater. The present cross-sectional study was designed to investigate the removal efficiency of total coliform and heterotrophic bacteria from surface water using the process. For this purpose, water samples were taken from the drinking water intake at Suleiman-Shahsonghur Dam. The electrocoagulation process was carried out in a Plexiglas reactor in the batch mode with Al and Fe used electrodes. The experiment design was carried out using the Design Expert Software (Stat-Ease Inc., Ver. 6.0.6. After each run, the values of metals dissolved due to anode electrode dissolution were measured using the Inductively Coupled Plasma (ICP and the results were analyzed using the RSM model. Results revealed maximum removal efficiencies of 100% and 89.1% for total coliform and heterotrophic bacteria using the Al electrode, respectively. Also, maximum removal efficiencies using the Fe electrode for the same pollutants were 100% and 76.1%. The measurements clearly indicate that the quantities of Al and Fe released in water were higher than the recommended values. While the electrocoagulation process showed to be effective in removing microbial agents from surface waters, the high concentrations of dissolved metals due to the dissolution of the anode electrode seem to remain a health problem that requires optimal conditions to be determined for acheiving standard concentrations of the dissolved metals.

  11. Enhancement of oxygen transfer and nitrogen removal in a membrane separation bioreactor for domestic wastewater treatment.

    Science.gov (United States)

    Chiemchaisri, C; Yamamoto, K

    2005-01-01

    Biological nitrogen removal in a membrane separation bioreactor developed for on-site domestic wastewater treatment was investigated. The bioreactor employed hollow fiber membrane modules for solid-liquid separation so that the biomass could be completely retained within the system. Intermittent aeration was supplied with 90 minutes on and off cycle to achieve nitrification and denitrification reaction for nitrogen removal. High COD and nitrogen removal of more than 90% were achieved under a moderate temperature of 25 degrees C. As the temperature was stepwise decreased from 25 to 5 degrees C, COD removal in the system could be constantly maintained while nitrogen removal was deteriorated. Nevertheless, increasing aeration supply could enhance nitrification at low temperature with benefit from complete retention of nitrifying bacteria within the system by membrane separation. At low operating temperature range of 5 degrees C, nitrogen removal could be recovered to more than 85%. A mathematical model considering diffusion resistance of limiting substrate into the bio-particle is applied to describe nitrogen removal in a membrane separation bioreactor. The simulation suggested that limitation of the oxygen supply was the major cause of inhibition of nitrification during temperature decrease. Nevertheless, increasing aeration could promote oxygen diffusion into the bio-particle. Sufficient oxygen was supplied to the nitrifying bacteria and the nitrification could proceed. In the membrane separation bioreactor, biomass concentration under low temperature operation was allowed to increase by 2-3 times of that of moderate temperature to compensate for the loss of bacterial activities so that the temperature effect was masked.

  12. Anaerobic treatment of slaughterhouse waste using a granular sludge UASB reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sayed, S.; Campen, L.V.; Lettinga, G.

    1987-01-01

    This study was carried out to assess the feasibility of the upflow granular anaerobic sludge blanket (UASB) process for one-stage anaerobic treatment of unsettled slaughterhouse wastewater, which contains approximately 50% insoluble coarse suspended COD. The experiments used continuous feeding (24 h day) during the working days combined with weekend feed interruptions at 30 degrees C and 20 degrees C. An organic space load up to 11 and 7 kg COD/cubic m/day was satisfactorily accommodated at process temperatures of 30 degrees C and 20 degrees C, respectively, with a treatment efficiency up to 55% on COD total basis and 85% on COD filtered basis. The system was less effective in the removal of the coarse Suspended Solids than the removal of the colloidal and soluble fractions. The data indicate that a proper application of a one-stage granular UASB system treating unsettled wastewater, such as slaughterhouse waste, strongly depends on the processes involved in the removal of the colloidal and soluble fraction from the waste and on its conversion into methane. Under the optimal loading conditions of 11 kg COD/cubic m/day (30 degrees C) and 7 kg COD/cubic m/day (20 degrees C) the conversion of removed colloidal and soluble materials into methane was up to 87% and 82%. However, the system still performed very satisfactorily in the removal of the colloidal and soluble pollutants up to loading rates of 15 and 9 kg COD/cubic m/day at 30 degrees C and 20 degrees C, respectively, although the conversion of the removed organic matter into methane dropped dramatically, rendering the application of the process under these conditions unattractive, if not impossible. (Refs. 16).

  13. Dose of Biocoagulant-Mixing Rate Combinations for Optimum Reduction of COD in Wastewater

    Science.gov (United States)

    Patricia, Maria Faustina; Purwono; Budihardjo, Mochamad Arief

    2018-02-01

    Chemical oxygen demand (COD) in domestic wastewater can be treated using flocculation-coagulation process with addition of Oyster mushroom (Pleurotus ostreatus) in powder form as biocoagulant. The fungal cell wall of Oyster mushroom comprises of chitin that is high polyelectrolyte and can be function as an absorbent of heavy metals in wastewater. The effectiveness of flocculation-coagulation process in treating wastewater depends on dose of coagulant and mixing rate. Therefore, this study aims to determine the best combination of three variation of dose of biocoagulant which are 600 mg/l, 1000 mg/l, and 2000 mg/l and mixing rate which are 100 rpm, 125 rpm, and 150 rpm that give the most reduction of COD in the wastewater. The result indicates that the combination of 1000 mg/l of biocoagulant and 100 rpm of mixing rate were found to be the most optimum combination to treat COD in the wastewater with COD reduction of 47.7%.

  14. Dose of Biocoagulant-Mixing Rate Combinations for Optimum Reduction of COD in Wastewater

    Directory of Open Access Journals (Sweden)

    Faustina Patricia Maria

    2018-01-01

    Full Text Available Chemical oxygen demand (COD in domestic wastewater can be treated using flocculation-coagulation process with addition of Oyster mushroom (Pleurotus ostreatus in powder form as biocoagulant. The fungal cell wall of Oyster mushroom comprises of chitin that is high polyelectrolyte and can be function as an absorbent of heavy metals in wastewater. The effectiveness of flocculation-coagulation process in treating wastewater depends on dose of coagulant and mixing rate. Therefore, this study aims to determine the best combination of three variation of dose of biocoagulant which are 600 mg/l, 1000 mg/l, and 2000 mg/l and mixing rate which are 100 rpm, 125 rpm, and 150 rpm that give the most reduction of COD in the wastewater. The result indicates that the combination of 1000 mg/l of biocoagulant and 100 rpm of mixing rate were found to be the most optimum combination to treat COD in the wastewater with COD reduction of 47.7%.

  15. Improvement of the degradation of sulfate rich wastewater using sweetmeat waste (SMW) as nutrient supplement

    Energy Technology Data Exchange (ETDEWEB)

    Das, Bidus Kanti [Department of Mining Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India); Roy, Shantonu [Department of Biotechnology, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India); Dev, Subhabrata [Department of Mining Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India); Das, Debabrata [Department of Biotechnology, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India); Bhattacharya, Jayanta, E-mail: jayantaism@gmail.com [Department of Mining Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India); School of Environmental Science and Engineering, Indian Institute of Technology Kharagpur, Kharagpur, 721302 (India)

    2015-12-30

    Highlights: • Sweetmeat waste (SMW) as a nutrient supplement in the SO{sub 4}{sup 2−} reduction system. • COD/SO{sub 4}{sup 2−} ratio of 4 was found suitable for SO{sub 4}{sup 2−} removal. • Sulfate reducing and acidogenic bacteria were dominant microbes in the system. • Microbial diversities were almost remained unaltered at different COD/SO{sub 4}{sup 2−} ratios. - Abstract: External dosing of sweetmeat waste (SMW) dosing into exhausted upflow packed bed bioreactor (PBR) resulted in prompt reactivation of SO{sub 4}{sup 2−} removal. Different SMW concentrations in terms of chemical oxygen demand (COD)/SO{sub 4}{sup 2−} ratios (1, 2, 4 and 8) were introduced into four identical PBR where process stability was found within 3 weeks of operation. SO{sub 4}{sup 2−} removal was proportional to COD/SO{sub 4}{sup 2−} ratios up to 4 at which maximum sulfate removal (99%) was achieved at a rate of 607 mg/d. The value of COD {sub consumption}:SO{sub 4}{sup 2−}{sub removal} was much higher at ratio 4 than 8 whereas, ratio 2 was preferred over all. Net effluent acetate concentration profile and total microbial population attached to the reactor matrices were corresponding to COD/SO{sub 4}{sup 2−} ratio as 4 > 8 > 2 >> 1. Sulfate reducing bacteria (SRB) population was found to be inversely proportional to COD/SO{sub 4}{sup 2−} ratio in which acetate oxidizing SRB and fermentative bacteria were the dominant.

  16. Historic changes in length distributions of three Baltic cod (Gadus morhua) stocks: Evidence of growth retardation.

    Science.gov (United States)

    Svedäng, Henrik; Hornborg, Sara

    2017-08-01

    Understanding how combinations of fishing effort and selectivity affect productivity is central to fisheries research. We investigate the roles of fishing regulation in comparison with ecosystem status for Baltic Sea cod stock productivity, growth performance, and population stability. This case study is interesting because three cod populations with different exploitation patterns and stock status are located in three adjacent but partially, ecologically different areas. In assessing stock status, growth, and productivity, we use survey information and rather basic stock parameters without relying on age readings. Because there is an urgent interest of better understanding of the current development of the Eastern Baltic cod stock, we argue that our approach represents partly a novel way of interpreting monitoring information together with catch data in a simplified yet more informative way. Our study reports how the Eastern and Western Baltic cod have gone toward more truncated size structures between 1991 and 2016, in particular for the Eastern Baltic cod, whereas the Öresund cod show no trend. We suggest that selective fishing may disrupt fish population dynamic stability and that lower natural productivity might amplify the effects of selective fishing. In support of earlier findings on a density-dependent growth of Eastern Baltic cod, management is advised to acknowledge that sustainable exploitation levels for Eastern Baltic cod are much more limited than perceived in regular assessments. Of more general importance, our results emphasize the need to embrace a more realistic view on what ecosystems can produce regarding tractable fish biomass to facilitate a more ecosystem-based fisheries management.

  17. Organics and nitrogen removal from textile auxiliaries wastewater with A2O-MBR in a pilot-scale

    International Nuclear Information System (INIS)

    Sun, Faqian; Sun, Bin; Hu, Jian; He, Yangyang; Wu, Weixiang

    2015-01-01

    Highlights: • A pilot-scale A 2 O-MBR system treating textile auxiliaries wastewater was assessed. • Organic matter and recycle ratio strongly affected the performance of the system. • GC/MS analysis found some refractory organics in the MBR permeate. • Combination of organic foulants and inorganic compounds caused membrane fouling. - Abstract: The removal of organic compounds and nitrogen in an anaerobic–anoxic–aerobic membrane bioreactor process (A 2 O-MBR) for treatment of textile auxiliaries (TA) wastewater was investigated. The results show that the average effluent concentrations of chemical oxygen demand (COD), ammonium nitrogen (NH 4 + –N) and total nitrogen (TN) were about 119, 3 and 48 mg/L under an internal recycle ratio of 1.5. The average removal efficiency of COD, NH 4 + –N and TN were 87%, 96% and 55%, respectively. Gas chromatograph–mass spectrometer analysis indicated that, although as much as 121 different types of organic compounds were present in the TA wastewater, only 20 kinds of refractory organic compounds were found in the MBR effluent, which could be used as indicators of effluents from this kind of industrial wastewater. Scanning electron microscopy analysis revealed that bacterial foulants were significant contributors to membrane fouling. An examination of foulants components by wavelength dispersive X-ray fluorescence showed that the combination of organic foulants and inorganic compounds enhanced the formation of gel layer and thus caused membrane fouling. The results will provide valuable information for optimizing the design and operation of wastewater treatment system in the textile industry

  18. Recovery in eastern Baltic cod: is increased recruitment caused by decreased predation on early life stages?

    DEFF Research Database (Denmark)

    Neumann, Viola; Köster, Fritz; Schaber, M.

    2014-01-01

    Cod (Gadus morhua) recruitment in the eastern Baltic Sea is influenced by predation on early life stages by sprat (Sprattus sprattus) and herring (Clupea harengus), which is considered as one of the mechanisms preventing cod recovery in the 1990s. In the light of improved cod recruitment...... in the second half of the 2000s, new analyses of stomach content of sprat and herring were conducted, to elucidate the contribution of changes in predation pressure on cod recruitment. Comparison of stomach contents of sprat and herring in 2004–2008 with data from the 1990s showed a similar diet composition...

  19. Isolation of putative probionts from cod rearing environment

    DEFF Research Database (Denmark)

    Lauzon, H.L.; Gudmundsdottir, S.; Pedersen, M.H.

    2008-01-01

    , metabolite production and adhesion to fish cell lines. Our study demonstrated that 14% of screened bacteria (n = 188) had antagonistic properties towards fish pathogens. The majority of these isolates were Gram-positive (81%), belonging to Firmicutes (69.2%) and Actinobacteria (11.5%) phyla based on 16S r...... was designed to search for new probiotics to target this critical period in cod rearing. Potential probionts were selected from the naturalmicrobiota of cod aquacultural environment. The selection was based on several criteria: pathogen inhibition potential, growth characteristics, strain identification......RNA gene sequencing. Only 6 (3.2%) of 188 isolates could inhibit all three pathogens tested: Vibrio anguillarum, Aeromonas salmonicida subsp. achromogenes and Vibrio salmonicida. Differences observed in activity intensity and spectrum among inhibitory isolates emphasise the need to develop probiotic...

  20. The mechanism of enhanced wastewater nitrogen removal by photo-sequencing batch reactors based on comprehensive analysis of system dynamics within a cycle.

    Science.gov (United States)

    Ye, Jianfeng; Liang, Junyu; Wang, Liang; Markou, Giorgos

    2018-07-01

    To understand the mechanism of enhanced nitrogen removal by photo-sequencing batch reactors (photo-SBRs), which incorporated microalgal photosynthetic oxygenation into the aerobic phases of a conventional cycle, this study performed comprehensive analysis of one-cycle dynamics. Under a low aeration intensity (about 0.02 vvm), a photo-SBR, illuminated with light at 92.27 μ·mol·m -2 ·s -1 , could remove 99.45% COD, 99.93% NH 4 + -N, 90.39% TN, and 95.17% TP, while the control SBR could only remove 98.36% COD, 83.51% NH 4 + -N, 78.96% TN, and 97.75% TP, for a synthetic domestic sewage. The specific oxygen production rate (SOPR) of microalgae in the photo-SBR could reach 6.63 fmol O 2 ·cell -1 ·h -1 . One-cycle dynamics shows that the enhanced nitrogen removal by photo-SBRs is related to photosynthetic oxygenation, resulting in strengthened nitrification, instead of direct nutrient uptake by microalgae. A too high light or aeration intensity could deteriorate anoxic conditions and thus adversely affect the removal of TN and TP in photo-SBRs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Flocculent Settling of Food Wastes.

    Science.gov (United States)

    Chowdhury, Mohammad Monirul Islam; Kim, Mingu; Haroun, Basem Mikhaeil; Nakhla, George; Keleman, Michael

    2016-07-01

    This study evaluated the flocculent settling in water and municipal wastewater (MWW) in a 10.6 ft deep column. A total of eight runs at three different testing conditions involving MWW alone, food waste (FW) alone, and FW in MWW (FW+MWW) were conducted. Total suspended solid (TSS), total BOD (TBOD), total COD (TCOD), total nitrogen (TN), and total phosphorous (TP) removal efficiencies after 3 hours of settling were 62%, 46%, 49%, 46% and 62% for FW, and 50%, 43%, 39%, 37% and 24% for MWW. Removal efficiencies of particulate COD (PCOD) and particulate BOD (PBOD) at the lowest surface overflow rate (SOR) of 1.1 m3/m2/hr corresponding to the longest settling time of 3 hours were 59% and 64% for FW, and 65% and 70% for FW with MWW samples. On the other hand, no significant variation between FW and FW with MWW was observed for PN removal after 3 hours of settling.

  2. Improvement of municipal wastewater pretreatment by direct membrane filtration.

    Science.gov (United States)

    Nascimento, Thiago A; Mejía, Fanny R; Fdz-Polanco, Fernando; Peña Miranda, Mar

    2017-10-01

    The high content of particulate matter in municipal wastewater hinders the conventional anaerobic treatments at psychrophilic temperatures. The hydrolysis of the particulate chemical oxygen demand (pCOD) could be the limiting step under these conditions. Therefore, new pretreatments or improved conventional pretreatments are needed in order to separate pCOD. In this work, direct membrane filtration of municipal wastewater, using an ultrafiltration membrane, was investigated. This intensive pretreatment, which aims to separate soluble chemical oxygen demand (sCOD) and to concentrate pCOD, together with anaerobic treatments of both streams at psychrophilic and mesophilic conditions respectively, could be an alternative to the conventional activated sludge process. The obtained results show a removal yield of 24.9% of the total solids (TS) and 45% of total chemical oxygen demand (tCOD), obtaining a permeate free of suspended solids. This physical removal implies the accumulation of solids inside the membrane tank, reaching the values of 45.4 and 4.4 g/L of TS in the sedimentation and filtration sections, respectively. The membrane operated with filtration, backwashing cycles and continuous gas sparging, with a permeate flux predominantly around 10 L/(m 2  h). The results show the viability of the technology to concentrate pCOD and so to improve energy recovery from municipal wastewater.

  3. Significance of Charpy and COD tests in the determination of fracture toughness of welds

    International Nuclear Information System (INIS)

    Caminha Junior, H.M.; Bastian, F.L.

    1983-01-01

    A comparison is made between the Charpy and crack opening displacement (COD) tests used to acess the fracture toughness of metallic materials. The main problems inherent in these tests are discussed, such as scatter of results and their advantages and limitations. The chief experimental difficulties when they are applied to welds are indicated and the various methods available for calculating the COD from a test graph are described. Comments are made on the use of the Charpy test and the methods of calculating the COD in determing critical defect sizes in welded structures. (Author) [pt

  4. Continuous removal and recovery of tellurium in an upflow anaerobic granular sludge bed reactor

    International Nuclear Information System (INIS)

    Mal, Joyabrata; Nancharaiah, Yarlagadda V.; Maheshwari, Neeraj; Hullebusch, Eric D. van; Lens, Piet N.L.

    2017-01-01

    Highlights: • Tellurite bioreduction coupled to recovery of biogenic Te(0) nanocrystals. • First report on continuous tellurite removal in a UASB reactor. • Biogenic Te(0) was mainly associated with loosely-bound EPS of granular sludge. • Repeated exposure to tellurite caused compositional changes in the EPS matrix. - Abstract: Continuous removal of tellurite (TeO 3 2− ) from synthetic wastewater and subsequent recovery in the form of elemental tellurium was studied in an upflow anaerobic granular sludge bed (UASB) reactor operated at 30 °C. The UASB reactor was inoculated with anaerobic granular sludge and fed with lactate as carbon source and electron donor at an organic loading rate of 0.6 g COD L −1 d −1 . After establishing efficient and stable COD removal, the reactor was fed with 10 mg TeO 3 2− L −1 for 42 d before increasing the influent concentration to 20 mg TeO 3 2− L −1 . Tellurite removal (98 and 92%, respectively, from 10 and 20 mg Te L −1 ) was primarily mediated through bioreduction and most of the removed Te was retained in the bioreactor. Characterization using XRD, Raman spectroscopy, SEM-EDX and TEM confirmed association of tellurium with the granular sludge, typically in the form of elemental Te(0) deposits. Furthermore, application of an extracellular polymeric substances (EPS) extraction method to the tellurite reducing sludge recovered up to 78% of the tellurium retained in the granular sludge. This study demonstrates for the first time the application of a UASB reactor for continuous tellurite removal from tellurite-containing wastewater coupled to elemental Te(0) recovery.

  5. The effect of primary sedimentation on full-scale WWTP nutrient removal performance.

    Science.gov (United States)

    Puig, S; van Loosdrecht, M C M; Flameling, A G; Colprim, J; Meijer, S C F

    2010-06-01

    Traditionally, the performance of full-scale wastewater treatment plants (WWTPs) is measured based on influent and/or effluent and waste sludge flows and concentrations. Full-scale WWTP data typically have a high variance which often contains (large) measurement errors. A good process engineering evaluation of the WWTP performance is therefore difficult. This also makes it usually difficult to evaluate effect of process changes in a plant or compare plants to each other. In this paper we used a case study of a full-scale nutrient removing WWTP. The plant normally uses presettled wastewater, as a means to increase the nutrient removal the plant was operated for a period by-passing raw wastewater (27% of the influent flow). The effect of raw wastewater addition has been evaluated by different approaches: (i) influent characteristics, (ii) design retrofit, (iii) effluent quality, (iv) removal efficiencies, (v) activated sludge characteristics, (vi) microbial activity tests and FISH analysis and, (vii) performance assessment based on mass balance evaluation. This paper demonstrates that mass balance evaluation approach helps the WWTP engineers to distinguish and quantify between different strategies, where others could not. In the studied case, by-passing raw wastewater (27% of the influent flow) directly to the biological reactor did not improve the effluent quality and the nutrient removal efficiency of the WWTP. The increase of the influent C/N and C/P ratios was associated to particulate compounds with low COD/VSS ratio and a high non-biodegradable COD fraction. Copyright 2010 Elsevier Ltd. All rights reserved.

  6. [NH4+-N removal stability of zeolite media packed multistage-biofilm system for coke-plant wastewater treatment].

    Science.gov (United States)

    Zhao, Wen-Tao; Huang, Xia; He, Miao; Zhang, Peng-Yi; Zuo, Chen-Yan

    2009-02-15

    The practical ammonia stripping effectiveness of coke-plant wastewater treatment may vary widely, and high NH4+-N shock loading will lead to the fluctuation of residual NH4+-N concentration of biological effluent. A zeolite media packed multistage-biofilm system (ZMBS) was used for coke-plant wastewater treatment for enhancing the NH4+-N treatment ability of the bio-system to shock loading, as well as achieving high COD removal efficiency. Treatment performance during steady-state and shock loading and transformation of organic pollutants in the system were investigated systematically. The experiment results indicated that when the system was operated at NH4+-N loading 0.21 kg/(m3 x d) and COD loading NH4+-N and COD concentrations were (2.2 +/- 1.2) mg/L, (228 +/- 60) mg/L with average removal efficiencies of (99.1 +/- 0.5)% and (86.0 +/- 2.6)%. During the twice NH4+-N shock loadings [0.03 kg/(m3 x d) and 0.06 kg/(m3 x d)], ZMBS showed a strong resisting ability with average removal efficiencies of 99.0% and 92.9% higher than those of a compared system's 96.8% and 89.3%. By monitoring the change of water quality along the length of the ZMBS's cells, two function zones for different pollutant removal were found to exist, named as decarbonization/nitrification (C/N) zone and nitrification (N) zone, and the NH4+-N removal rate in N zone was 2-8 times as that in C/N zone. TOC concentrations of organic matters with relative molecular weight 1 x 10(4), were 227.6, 104.8 and 35.0 mg/L in raw wastewater, and 31.2, 22.9 and 31.5 mg/L in the effluent, respectively. Organic matters with relative molecular weight 1x 10(3) were the main remained substances in the effluent.

  7. 77 FR 62464 - Fisheries of the Exclusive Economic Zone Off Alaska; Pacific Cod by Vessels Using Pot Gear in the...

    Science.gov (United States)

    2012-10-15

    ... Vessels Using Pot Gear in the Central Regulatory Area of the Gulf of Alaska AGENCY: National Marine... gear in the Central Regulatory Area of the Gulf of Alaska (GOA). This action is necessary to prevent exceeding the 2012 Pacific cod total allowable catch apportioned to vessels using pot gear in the Central...

  8. Annual and spatial variability in endo- and ectoparasite infections of North Sea cod (Gadus morhua Linnaeus, 1758) larvae, post-larvae and juveniles

    DEFF Research Database (Denmark)

    Mehrdana, Foojan; Bahlool, Qusay Z. M.; Skovgaard, Alf

    2014-01-01

    A parasitological investigation was performed on a total of 5380 Atlantic cod larvae, post-larvae and small juveniles sampled from the North Sea during a period of five years. The copepod Caligus elongatus (Von Nordmann, 1832) and the nematode Hysterothylacium aduncum (Rudolphi, 1802) were found ...

  9. Thawed cod fillets spoil less rapidly than unfrozen fillets when stored under modified atmosphere at 2 degrees C.

    Science.gov (United States)

    Guldager, H S; Bøknaes, N; Osterberg, C; Nielsen, J; Dalgaard, P

    1998-09-01

    The effect of two months of frozen storage at -20 degrees C on the spoilage characteristics and shelf life of thawed and modified atmosphere packed (MAP) cod fillets stored at 2 degrees C was studied. Thawed MAP cod fillets were compared with fresh cod fillets stored in CO2-containing modified atmospheres with and without added oxygen. The shelf life of 11 to 12 days in the fresh MAP cod was extended to more than 20 days in the thawed MAP cod at 2 degrees C. This shelf life extension was most likely due to the inactivation of the spoilage bacterium Photobacterium phosphoreum during frozen storage as reflected both in chemical analyses and sensory evaluation. In contrast to fresh MAP cod fillets no significant production of trimethylamine occurred and almost no amine odor and taste were detected during 20 days of chill storage of thawed MAP cod fillets. The use of frozen fillets as raw material not only provides a more stable product in MAP but also allows much greater flexibility for production and distribution. However, a slightly increased concentration of dimethylamine, a larger drip loss, and detection of weak frozen storage flavor were observed in the thawed MAP cod fillets.

  10. Integrated electrocoagulation-electrooxidation process for the treatment of soluble coffee effluent: Optimization of COD degradation and operation time analysis.

    Science.gov (United States)

    Ibarra-Taquez, Harold N; GilPavas, Edison; Blatchley, Ernest R; Gómez-García, Miguel-Ángel; Dobrosz-Gómez, Izabela

    2017-09-15

    Soluble coffee production generates wastewater containing complex mixtures of organic macromolecules. In this work, a sequential Electrocoagulation-Electrooxidation (EC-EO) process, using aluminum and graphite electrodes, was proposed as an alternative way for the treatment of soluble coffee effluent. Process operational parameters were optimized, achieving total decolorization, as well as 74% and 63.5% of COD and TOC removal, respectively. The integrated EC-EO process yielded a highly oxidized (AOS = 1.629) and biocompatible (BOD 5 /COD ≈ 0.6) effluent. The Molecular Weight Distribution (MWD) analysis showed that during the EC-EO process, EC effectively decomposed contaminants with molecular weight in the range of 10-30 kDa. In contrast, EO was quite efficient in mineralization of contaminants with molecular weight higher than 30 kDa. A kinetic analysis allowed determination of the time required to meet Colombian permissible discharge limits. Finally, a comprehensive operational cost analysis was performed. The integrated EC-EO process was demonstrated as an efficient alternative for the treatment of industrial effluents resulting from soluble coffee production. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Spatial and Temporal Patterns in the Cod Fisheries of the North Atlantic

    Directory of Open Access Journals (Sweden)

    Anne Hayden

    2015-01-01

    Full Text Available Atlantic Cod Gadus morhua has been subject to commercial exploitation since the thirteenth century. An analysis of cod fisheries over space and time reveals a pattern of serial depletion that reflects the cross-scale interaction of fish population structure, economic incentives, developments in fishing technology, and government efforts to limit access to fishing areas. Three case studies from Newfoundland and Labrador, the larger Northwest Atlantic, and the Gulf of Maine illustrate a pattern of fish population depletion followed by expansion of fishing activity that repeats at a range of scales. The meta-population structure of cod populations allows overharvesting, even when strict but broadscale controls are in place. The results argue for the reform of fisheries management to incorporate governance that more closely reflects the scale of the local components of metapopulations.

  12. Effects of a polymeric organic coagulant for industrial mineral oil ...

    African Journals Online (AJOL)

    The removal of chemical oxidation demand (COD), soap oil and grease (SOG), total suspended solids (TSS) and turbidity from the MOW were used as the response variables for the coagulation flotation process. This was done with a standard dissolved air flotation jar test. The results show that the actual COD, SOG, TSS ...

  13. Slave to the rhythm: seasonal signals in otolith microchemistry reveal age of eastern Baltic cod (Gadus morhua)

    DEFF Research Database (Denmark)

    Hüssy, Karin; Gröger, J.; Heidemann, F.

    2016-01-01

    Annual growth zones in cod otoliths from the eastern Baltic stock are less discrete than in other cod stocks leading to biased age reading, which recently led to a failure of age-based assessment in the eastern Baltic cod stock. In this study, we explored the applicability of minor and trace elem...

  14. Thawed cod fillets spoil less rapidly than unfrozen fillets when stored under modified atmosphere at 2 C

    DEFF Research Database (Denmark)

    Guldager, H.S.; Bøknæs, Niels; Østerberg, Carsten

    1998-01-01

    The effect of two months of frozen storage at -20 degrees C on the spoilage characteristics and shelf life of thawed and modified atmosphere packed (MAP) cod fillets stored at 2 degrees C was studied. Thawed MAP cod fillets were compared with fresh cod fillets stored in CO2-containing modified at...

  15. Performance Evaluation of Anaerobic-Aerobic Treatment for the Wastewater of Potato Processing Industry: A Case Study of a Local Chips Factory

    International Nuclear Information System (INIS)

    Haydar, S.; Nadeem, O.

    2014-01-01

    A study was conducted to assess the performance of anaerobic-aerobic treatment system of a local potato processing industry. The wastewater treatment plant (WWTP) consisted of primary treatment, upflow anaerobic sludge blanket (UASB), activated sludge process (ASP) and secondary clarifier. The study analyzed the physical, chemical and biochemical parameters of the influent (raw sewage) as well as the effluent from each component of the plant. Grab wastewater samples were collected on weekly basis and analyzed for the pH, settleable solids (SS), total suspended solids (TSS), total dissolved solids (TDS), biochemical oxygen demand (BOD), and chemical oxygen demand (COD). Study revealed that mean influent wastewater concentrations of TSS, TDS, SS, BOD and COD were 840 mg/L, 2,396 mg/L and 18.7 mL/L, 2,186 mg/L and 3,679 mg/L, respectively. The mean percentage removal efficiency in UASB for TSS, BOD and COD was found to be 56%, 61 % and 51%, respectively. The mean percentage removal efficiency in activated sludge system for TSS, BOD and COD was found to be 70%, 57% and 48%, respectively. The mean percentage removal efficiency of combined anaerobic-aerobic system for TSS, BOD and COD was found to be 93%, 90% and 80%, respectively. The mean effluent concentrations of TSS, BOD and COD were 52 mg/L, 197 mg/L and 784 mg/L, respectively. The effluent from WWTP satisfied NEQS for TSS (200 mg/L) while NEQS for BOD (80 mg/L) and COD (150 mg/L) were not satisfied. Some operational problems, responsible for inadequate efficiencies of the plant components, were identified and solutions were suggested for these problems. (author)

  16. Removal of pharmaceuticals in WWTP effluents by ozone and hydrogen peroxide

    DEFF Research Database (Denmark)

    Hey, G.; Vega, S. R.; Fick, J.

    2014-01-01

    to ozone treatment could improve the removal and lower the reaction time. The effluents studied differed in their chemical characteristics, particularly in terms of alkalinity (65.3–427 mg·l-1) HCO3-), COD (18.2–41.8 mg·l-1), DOC (6.9–12.5 mg·l-1), ammonium content (0.02–3.6 mg·l-1) and specific UV...

  17. Organics and nitrogen removal from textile auxiliaries wastewater with A{sup 2}O-MBR in a pilot-scale

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Faqian [Institute of Environmental Science and Technology, Zhejiang University, Hangzhou 310058 (China); Sun, Bin [Institute of Environmental Science and Technology, Zhejiang University, Hangzhou 310058 (China); Shanghai Electric Group Co. Ltd. Central Academe, Shanghai 200070 (China); Hu, Jian; He, Yangyang [Institute of Environmental Science and Technology, Zhejiang University, Hangzhou 310058 (China); Wu, Weixiang, E-mail: weixiang@zju.edu.cn [Institute of Environmental Science and Technology, Zhejiang University, Hangzhou 310058 (China)

    2015-04-09

    Highlights: • A pilot-scale A{sup 2}O-MBR system treating textile auxiliaries wastewater was assessed. • Organic matter and recycle ratio strongly affected the performance of the system. • GC/MS analysis found some refractory organics in the MBR permeate. • Combination of organic foulants and inorganic compounds caused membrane fouling. - Abstract: The removal of organic compounds and nitrogen in an anaerobic–anoxic–aerobic membrane bioreactor process (A{sup 2}O-MBR) for treatment of textile auxiliaries (TA) wastewater was investigated. The results show that the average effluent concentrations of chemical oxygen demand (COD), ammonium nitrogen (NH{sub 4}{sup +}–N) and total nitrogen (TN) were about 119, 3 and 48 mg/L under an internal recycle ratio of 1.5. The average removal efficiency of COD, NH{sub 4}{sup +}–N and TN were 87%, 96% and 55%, respectively. Gas chromatograph–mass spectrometer analysis indicated that, although as much as 121 different types of organic compounds were present in the TA wastewater, only 20 kinds of refractory organic compounds were found in the MBR effluent, which could be used as indicators of effluents from this kind of industrial wastewater. Scanning electron microscopy analysis revealed that bacterial foulants were significant contributors to membrane fouling. An examination of foulants components by wavelength dispersive X-ray fluorescence showed that the combination of organic foulants and inorganic compounds enhanced the formation of gel layer and thus caused membrane fouling. The results will provide valuable information for optimizing the design and operation of wastewater treatment system in the textile industry.

  18. Treatment of Olive Mill Wastewater with Constructed Wetlands

    Directory of Open Access Journals (Sweden)

    Andreas N. Angelakis

    2012-03-01

    Full Text Available The objective of this study was to investigate the application of constructed wetlands as a mean to manage olive mill wastewater (OMW. Two free water surface (FWS constructed wetlands, one without (CW1 and one with effluent recirculation (CW2, were operated for a two-year period with diluted OMW (1:10 and evaluated in terms of the removal of COD, TSS, TKN, NH4+-N, NO3−-N, TP and total phenols. The organic loading rate of CWs was adjusted to 925 kg BOD/ha·d. In CW1 the removal efficiency averaged 80%, 83%, 78%, 80%, and 74% for COD, TSS, TKN, TP, and total phenols, respectively, during the operation period. Effluent recirculation further improved the treatment efficiency which approached 90%, 98%, 87%, 85%, and 87% for COD, TSS, TKN, TP, and total phenols, respectively. Constructed wetlands also showed high removal efficiency for NH4+-N. Nitrate concentration maintained low in both CWs basins, probably due to the prevalence of high denitrification rates that efficiently removed the NO3--N produced by NH4+-N oxidation. Despite the increased removal percentages, pollutant concentration in effluent exceeded the allowable limits for discharge in water bodies, suggesting that additional practices, including enhanced pre-application treatment and/or higher dilution rates, are required to make this practice effective for OMW management.

  19. Efficiency of SBR Process with a Six Sequence Aerobic-Anaerobic Cycle for Phosphorus and Organic Material Removal from Municipal Wastewater

    Directory of Open Access Journals (Sweden)

    Nadiya Shahandeh

    2018-02-01

    Full Text Available Background: Various chemical, physical and biologic treatment methods are being used to remove nitrogen and phosphorus from wastewater. Sequencing batch reactor (SBR is a modified activated sludge process that removes phosphorus and organic material from sanitary wastewater, biologically. Methods: This study was conducted in 2016.The performance of an aerobic-anaerobic SBR pilot device, located at Ahwaz West Wastewater Treatment Plant, Ahwaz, southern Iran in phosphorus and organic material removal was evaluated to determine the effect of the aerobic-anaerobic step time on the efficiency of nitrogen and phosphorus removal, the effect of changing the sequence of steps and the effect of time ratio on phosphorus removal efficiency. A reactor of 8 L was used. Influent contained 397 and 10.7 mg/l COD and phosphorus, respectively. The pilot plant started with a 24 h cycle including four cycles of 6 h, as follows: 1- Loading (15 min, 2-Anaerobic (2 h-Aerobic (2 h, 3- Settling (1 h, Idleness (30 min and 5- decant (15 min. Results: After reaching steady conditions (6 months, Removal percentages of phosphorus, BOD5, COD, and TSS in The SBR over a period of 6 months was 79%, 86%, 89% and 83%, respectively. Conclusion: Result of this study can be used for designing and optimum operation of sequencing batch reactors.

  20. Hierarchical modelling of temperature and habitat size effects on population dynamics of North Atlantic cod

    DEFF Research Database (Denmark)

    Mantzouni, Irene; Sørensen, Helle; O'Hara, Robert B.

    2010-01-01

    and Beverton and Holt stock–recruitment (SR) models were extended by applying hierarchical methods, mixed-effects models, and Bayesian inference to incorporate the influence of these ecosystem factors on model parameters representing cod maximum reproductive rate and carrying capacity. We identified......Understanding how temperature affects cod (Gadus morhua) ecology is important for forecasting how populations will develop as climate changes in future. The effects of spawning-season temperature and habitat size on cod recruitment dynamics have been investigated across the North Atlantic. Ricker...

  1. The effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration

    International Nuclear Information System (INIS)

    Cheshmberah, F.; Solaimany Nazar, A.R.; Farhadian, M.

    2016-01-01

    An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial thin film composite polyamide nanofilter. The effects of p H (6.5-8.5), pressure (4-10 bar), concentration of total ammonia nitrogen (1-9 mg/L), and florfenicol (0.2-5 mg/L) on the removal efficiency of the nanofilter were studied at a constant 70% recovery rate. It was found that by increasing the p H within the range of 6.5 to 8.5, it enhanced the removal efficiency by up to 98% and 100% for total ammonia nitrogen and florfenicol, respectively. With an increase in pressure from 4 to 7 bar, the removal percentage increased and then, it decreased from 7 to 10 bar. The interactions factors did not have significant effects on the both pollutants removal efficiencies. To obtain optimal removal efficiencies, an experimental design and statistical analysis via the response surface method were adopted.

  2. Bioactivity of Cod and Chicken Protein Hydrolysates before and after in vitro Gastrointestinal Digestion

    DEFF Research Database (Denmark)

    Jamnik, Polona; Istenič, Katja; Wulff, Tune

    2017-01-01

    , where values of cod and chicken were (95.5±1.2) and (90.5±0.7) %, respectively. Neither species nor digestion had any effect on cellular metabolic energy. At proteome level, digested hydrolysates gave again significantly stronger responses than undigested counterparts; cod peptides here also gave...... somewhat stronger response than chicken peptides. The knowledge of the action of food protein hydrolysates and their digests within live cells, also at proteome level, is important for further validation of their activity in higher eukaryotes to develop new products, such as in this case chicken and cod...... muscle-derived peptides as functional ingredients....

  3. Rebuilding the eastern Baltic cod stock under environmental change (part II): taking into account the costs of a marine protected area

    NARCIS (Netherlands)

    Roeckmann, C.; Tol, R.S.J.; Schneider, U.A.; St.John, M.A.

    2009-01-01

    This study adds a cost analysis of the Eastern Baltic cod fishery to the existing model presented in Röckmann et al. [2007a]. As cost data on this international fishery do not exist, data from Denmark are extrapolated to the whole international fishery. Additionally, unit and total variable costs

  4. [Pollution load and the first flush effect of BOD5 and COD in urban runoff of Wenzhou City].

    Science.gov (United States)

    Wang, Jun; Bi, Chun-juan; Chen, Zhen-lou; Zhou, Dong

    2013-05-01

    Four typical rainfalls were monitored in two different research areas of Wenzhou Municipality. Concentrations of BOD5 and COD in six different urban runoffs were measured. In addition the event mean concentration (EMC), M (V) curve and BOD5/COD of pollutant were calculated. The results showed that concentrations of BOD5 and COD in different urban runoffs of Wenzhou ranged from ND to 69.21 mg x L(-1) and ND to 636 mg x L(-1). Concentrations of BOD5 and COD in different urban runoffs were decreasing over time, so it is greatly significant to manage the initial runoff for reducing organic pollution. Judged by EMC of BOD5 and COD in these five rainfalls, concentrations of pollutant in some urban runoffs were out of the integrated wastewater discharge standard. If these runoffs flowed into river, it would cause environmental pressure to the next level receiving water bodies. According to the M (V) curve, the first flush effect of COD in most urban runoffs was common; while the first flush effect of BOD5 was same as that of COD. The result also showed that organic pollution was serious at the beginning of runoff. The underlying surface type could affect the concentration of BOD5 and COD in urban runoff. While the results of BOD5/COD also suggested that biodegradation was considered as one of the effective ways to decrease the pollution load of organics in urban runoff, and the best management plans (BMPs) should be selected for various urban runoff types for the treatment of organic pollution.

  5. Effects of UV irradiation on humic acid removal by ozonation, Fenton and Fe0/air treatment: THMFP and biotoxicity evaluation

    International Nuclear Information System (INIS)

    Wei, Ming-Chi; Wang, Kai-sung; Hsiao, Tung-En; Lin, I.-Chen; Wu, Hui-Ju; Wu, Yuh-Luan; Liu, Pey-Horng; Chang, Shih-Hsien

    2011-01-01

    Highlights: → Fe 0 /air rapidly and effectively removed HA within 9 min and its COD, biotoxicity and THMFP were low. → THMFP of ozonation-treated solution was much higher than those of Fenton-treated and Fe 0 /air-treated solutions. → UV irradiation during ozonation and Fenton oxidation enhanced HA removal, but did not reduce the THMFP of the treated solutions. → Fe 0 /air treatment with UV irradiation obviously increased the THMFP of the treated solution. → The relationship between biotoxicity and chloroform in the chlorinated solution was insignificant. - Abstract: Effects of UV irradiation on humic acid (HA) removal by Fe 0 /air, ozonation and Fenton oxidation were investigated. The trihalomethane forming potential (THMFP) and toxicity of treated solutions were also evaluated. The experimental conditions were ozone of 21 mg min -1 , H 2 O 2 of 8 x 10 -4 M, Fe 0 of 20 g L -1 , air flow of 5 L min -1 , and UVC of 9 W. Results indicated that Fe 0 /air rapidly removed HA color (>99%) and COD (90%) within 9 min. 51-81% of color and 43-50% of COD were removed by ozonation and Fenton oxidation after 60 min. Both UV enhanced ozone and Fenton oxidation removed HA, but the Fe 0 /air process did not. Spectrum results showed all processes effectively diminished UV-vis spectra, except for ozonation. The THMFP of Fe 0 /air-treated solution (114 μg L -1 ) was much lower than those of Fenton- (226 μg L -1 ) and ozonation-treated solutions (499 μg L -1 ). Fe 0 /air with UV irradiation obviously increased the THMFP of treated solution (502 μg L -1 ). The toxicity results obtained from Vibrio fischeri light inhibition test indicated that the toxicity of Fe 0 /air-treated solution (5%) was much lower than that of ozonation- (33%) and Fenton-treated solutions (31%). Chlorination increased the solution toxicity. The correlation between biotoxicity and chloroform in the chlorinated solution was insignificant.

  6. Natural light-micro aerobic condition for PSB wastewater treatment: a flexible, simple, and effective resource recovery wastewater treatment process.

    Science.gov (United States)

    Lu, Haifeng; Han, Ting; Zhang, Guangming; Ma, Shanshan; Zhang, Yuanhui; Li, Baoming; Cao, Wei

    2018-01-01

    Photosynthetic bacteria (PSB) have two sets of metabolic pathways. They can degrade pollutants through light metabolic under light-anaerobic or oxygen metabolic pathways under dark-aerobic conditions. Both metabolisms function under natural light-microaerobic condition, which demands less energy input. This work investigated the characteristics of PSB wastewater treatment process under that condition. Results showed that PSB had very strong adaptability to chemical oxygen demand (COD) concentration; with F/M of 5.2-248.5 mg-COD/mg-biomass, the biomass increased three times and COD removal reached above 91.5%. PSB had both advantages of oxygen metabolism in COD removal and light metabolism in resource recovery under natural light-microaerobic condition. For pollutants' degradation, COD, total organic carbon, nitrogen, and phosphorus removal reached 96.2%, 91.0%, 70.5%, and 92.7%, respectively. For resource recovery, 74.2% of C in wastewater was transformed into biomass. Especially, coexistence of light and oxygen promote N recovery ratio to 70.9%, higher than with the other two conditions. Further, 93.7% of N-removed was synthesized into biomass. Finally, CO 2 emission reduced by 62.6% compared with the traditional process. PSB wastewater treatment under this condition is energy-saving, highly effective, and environment friendly, and can achieve pollution control and resource recovery.

  7. Organics removal from landfill leachate and activated sludge production in SBR reactors

    International Nuclear Information System (INIS)

    Klimiuk, Ewa; Kulikowska, Dorota

    2006-01-01

    This study is aimed at estimating organic compounds removal and sludge production in SBR during treatment of landfill leachate. Four series were performed. At each series, experiments were carried out at the hydraulic retention time (HRT) of 12, 6, 3 and 2 d. The series varied in SBR filling strategies, duration of the mixing and aeration phases, and the sludge age. In series 1 and 2 (a short filling period, mixing and aeration phases in the operating cycle), the relationship between organics concentration (COD) in the leachate treated and HRT was pseudo-first-order kinetics. In series 3 (with mixing and aeration phases) and series 4 (only aeration phase) with leachate supplied by means of a peristaltic pump for 4 h of the cycle (filling during reaction period) - this relationship was zero-order kinetics. Activated sludge production expressed as the observed coefficient of biomass production (Y obs ) decreased correspondingly with increasing HRT. The smallest differences between reactors were observed in series 3 in which Y obs was almost stable (0.55-0.6 mg VSS/mg COD). The elimination of the mixing phase in the cycle (series 4) caused the Y obs to decrease significantly from 0.32 mg VSS/mg COD at HRT 2 d to 0.04 mg VSS/mg COD at HRT 12 d. The theoretical yield coefficient Y accounted for 0.534 mg VSS/mg COD (series 1) and 0.583 mg VSS/mg COD (series 2). In series 3 and 4, it was almost stable (0.628 mg VSS/mg COD and 0.616 mg VSS/mg COD, respectively). After the elimination of the mixing phase in the operating cycle, the specific biomass decay rate increased from 0.006 d -1 (series 3) to 0.032 d -1 (series 4). The operating conditions employing mixing/aeration or only aeration phases enable regulation of the sludge production. The SBRs operated under aerobic conditions are more favourable at a short hydraulic retention time. At long hydraulic retention time, it can lead to a decrease in biomass concentration in the SBR as a result of cell decay. On the contrary

  8. Wastewater treatment in a hybrid activated sludge baffled reactor

    International Nuclear Information System (INIS)

    Tizghadam, Mostafa; Dagot, Christophe; Baudu, Michel

    2008-01-01

    A novel hybrid activated sludge baffled reactor (HASBR), which contained both suspended and attached-growth biomass perfect mixing cells in series, was developed by installing standing and hanging baffles and introducing plastic brushes into a conventional activated sludge (CAS) reactor. It was used for the treatment of domestic wastewater. The effects on the operational performance of developing the suspended and attached-growth biomass and reactor configuration were investigated. The change of the flow regime from complete-mix to plug-flow, and the addition of plastic brushes as a support for biofilm, resulted in considerable improvements in the COD, nitrogen removal efficiency of domestic wastewater and sludge settling properties. In steady state, approximately 98 ± 2% of the total COD and 98 ± 2% of the ammonia of the influent were removed in the HASBR, when the influent wastewater concentration was 593 ± 11 mg COD/L and 43 ± 5 mg N/L, respectively, at a HRT of 10 h. These results were 93 ± 3 and 6 ± 3% for the CAS reactor, respectively. Approximately 90 ± 7% of the total COD was removed in the HASBR, when the influent wastewater concentration was 654 ± 16 mg COD/L at a 3 h HRT, and in the organic loading rate (OLR) of 5.36 kg COD m -3 day -1 . The result for the CAS reactor was 60 ± 3%. Existing CAS plants can be upgraded by changing the reactor configuration and introducing biofilm support media into the aeration tank

  9. Simultaneous C and N removal from saline salmon effluents in filter reactors comprising anoxic-anaerobic-aerobic processes: effect of recycle ratio.

    Science.gov (United States)

    Giustinianovich, Elisa A; Aspé, Estrella R; Huiliñir, César E; Roeckel, Marlene D

    2014-01-01

    Salmon processing generates saline effluents with high protein load. To treat these effluents, three compact tubular filter reactors were installed and an integrated anoxic/anaerobic/aerobic process was developed with recycling flow from the reactor's exit to the inlet stream in order to save organic matter (OM) for denitrification. The reactors were aerated in the upper section with recycle ratios (RR) of 0, 2, and 10, respectively, at 30°C. A tubular reactor behave as a plug flow reactor when RR = 0, and as a mixed flow reactor when recycle increases, thus, different RR values were used to evaluate how it affects the product distribution and the global performance. Diluted salmon process effluent was prepared as substrate. Using loads of 1.0 kg COD m(-3)d(-1) and 0.15 kg total Kjeldahl nitrogen (TKN) m(-3)d(-1) at HRT of 2 d, 100% removal efficiencies for nitrite and nitrate were achieved in the anoxic-denitrifying section without effect of the dissolved oxygen in the recycled flow on denitrification. Removals >98% for total organic carbon (TOC) was achieved in the three reactors. The RR had no effect on the TOC removal; nevertheless a higher efficiency in total nitrogen removal in the reactor with the highest recycle ratio was observed: 94.3% for RR = 10 and 46.6% for RR = 2. Results showed that the proposed layout with an alternative distribution in a compact reactor can efficiently treat high organic carbon and nitrogen concentrations from a saline fish effluent with OM savings in denitrification.

  10. Screening three Finfish Species for their Potential in Removing Organic Matter from the Effluent of White Leg Shrimps (Litopenaeus vannamei Farming

    Directory of Open Access Journals (Sweden)

    Nguyen, LQ.

    2016-01-01

    Full Text Available White leg shrimp (Litopenaeus vannamei farming effluent contains pollutants that include high levels of organic matter (OM nutrients and growth-promoting substances. This study investigated the effects of varied concentrations of white leg shrimp (Litopenaeus vannamei farm wastewater 0, 50, 75 and 100%, on the survival rate (SR of three finfish species: tilapia (Oreochromis niloticus, grey mullet (Mugil cephalus and rabbit fish (Siganus guttatus as part of screening their potential in removing organic matter from the effluent of white leg shrimp farming. The different initial levels of shrimp wastewater from 50% to 100% had no significant effect on the survival rate of tilapia and mullet; but the survival rate of S. guttatus significantly decreased with increasing shrimp wastewater (P<0.05. The results showed that the removal of BOD, COD and TSS occurred in the range of 66-83, 68-81 and 30-54%; respectively and the removal efficiency of OM by mullet was higher than Tilapia in all treatments. The study also indicated that the reduction highest removal of BOD, COD and TSS was achieved being 83.1%, 80.7and 53,7% respectively, at the medium stocking density (25 fish/m2 of mullet.

  11. Electrochemical treatment of domestic wastewater using boron-doped diamond and nanostructured amorphous carbon electrodes.

    Science.gov (United States)

    Daghrir, Rimeh; Drogui, Patrick; Tshibangu, Joel; Delegan, Nazar; El Khakani, My Ali

    2014-05-01

    The performance of the electrochemical oxidation process for efficient treatment of domestic wastewater loaded with organic matter was studied. The process was firstly evaluated in terms of its capability of producing an oxidant agent (H2O2) using amorphous carbon (or carbon felt) as cathode, whereas Ti/BDD electrode was used as anode. Relatively high concentrations of H2O2 (0.064 mM) was produced after 90 min of electrolysis time, at 4.0 A of current intensity and using amorphous carbon at the cathode. Factorial design and central composite design methodologies were successively used to define the optimal operating conditions to reach maximum removal of chemical oxygen demand (COD) and color. Current intensity and electrolysis time were found to influence the removal of COD and color. The contribution of current intensity on the removal of COD and color was around 59.1 and 58.8%, respectively, whereas the contribution of treatment time on the removal of COD and color was around 23.2 and 22.9%, respectively. The electrochemical treatment applied under 3.0 A of current intensity, during 120 min of electrolysis time and using Ti/BDD as anode, was found to be the optimal operating condition in terms of cost/effectiveness. Under these optimal conditions, the average removal rates of COD and color were 78.9 ± 2 and 85.5 ± 2 %, whereas 70% of total organic carbon removal was achieved.

  12. Microaeration for hydrogen sulfide removal in UASB reactor.

    Science.gov (United States)

    Krayzelova, Lucie; Bartacek, Jan; Kolesarova, Nina; Jenicek, Pavel

    2014-11-01

    The removal of hydrogen sulfide from biogas by microaeration was studied in Up-flow Anaerobic Sludge Blanket (UASB) reactors treating synthetic brewery wastewater. A fully anaerobic UASB reactor served as a control while air was dosed into a microaerobic UASB reactor (UMSB). After a year of operation, sulfur balance was described in both reactors. In UASB, sulfur was mainly presented in the effluent as sulfide (49%) and in biogas as hydrogen sulfide (34%). In UMSB, 74% of sulfur was detected in the effluent (41% being sulfide and 33% being elemental sulfur), 10% accumulated in headspace as elemental sulfur and 9% escaped in biogas as hydrogen sulfide. The efficiency of hydrogen sulfide removal in UMSB was on average 73%. Microaeration did not cause any decrease in COD removal or methanogenic activity in UMSB and the elemental sulfur produced by microaeration did not accumulate in granular sludge. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. On the relation between water pools and water holding capacity in cod muscle

    DEFF Research Database (Denmark)

    Andersen, Charlotte Møller; Jørgensen, Bo

    2004-01-01

    Low-field 1H nuclear magnetic resonance (NMR) relaxations were measured on muscle, minced muscle and centrifuged mince from cod that had been treated under various frozen and chill storage conditions. By using multi-way chemometrics, uni-exponential profiles were obtained, from which the transverse...... relaxation times (T2-values) and the water pool sizes (m- values) were determined. Three pools of water were identified with the different relaxation times and m-values in the centrifuged samples reflecting the removal of loosely bound water. The m-values and the full NMR-signal decays were correlated to two...... measures of water holding capacity (WHC) in a way that WHC related to the original water content could be predicted well for the whole and the minced muscle. The centrifuged samples gave optimal predictions of WHC related to the dry matter content, probably because the centrifuged samples are similar...

  14. Removal of selected nitrogenous heterocyclic compounds in biologically pretreated coal gasification wastewater (BPCGW) using the catalytic ozonation process combined with the two-stage membrane bioreactor (MBR).

    Science.gov (United States)

    Zhu, Hao; Han, Yuxing; Ma, Wencheng; Han, Hongjun; Ma, Weiwei

    2017-12-01

    Three identical anoxic-aerobic membrane bioreactors (MBRs) were operated in parallel for 300 consecutive days for raw (R 1 ), ozonated (R 2 ) and catalytic ozonated (R 3 ) biologically pretreated coal gasification wastewater (BPCGW) treatment. The results demonstrated that catalytic ozonation process (COP) applied asa pretreatment remarkably improved the performance of the unsatisfactory single MBR. The overall removal efficiencies of COD, NH 3 -N and TN in R 3 were 92.7%, 95.6% and 80.6%, respectively. In addition, typical nitrogenous heterocyclic compounds (NHCs) of quinoline, pyridine and indole were completely removed in the integrated process. Moreover, COP could alter sludge properties and reshape microbial community structure, thus delaying the occurrence of membrane fouling. Finally, the total cost for this integrated process was estimated to be lower than that of single MBR. The results of this study suggest that COP is a good option to enhance pollutants removal and alleviate membrane fouling in the MBR for BPCGW treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Study of the aerobic biological treatment of slaughterhouse wastewater by membrane process

    International Nuclear Information System (INIS)

    Ben yahmed, Nesrine

    2011-01-01

    The objective of this work is to study the performance of aerobic treatment of slaughterhouse wastewater by a side-stream membrane bioreactor (MBR) with semi-frontal filtration and to evaluate the sludge production generated by this system treatment. The MBR was fed with a flow rate of 5 L/d. The wastewater used in this study was collected from the WWTP Ellouhoum following pretreatment operations. They are characterized by an average total COD concentration of approximately 2 g/L. The mass load applied to the system was 0.18 g COD/gVSS.d. The results show that COD and total nitrogen removal efficiencies are respectively estimated at 90.66 pour cent and 92.86 pour cent. Treatment with MBR also allows a total elimination of TSS, fecal coliforms and pathogens. With a total biomass recycling, low sludge yield (Yobs) of 0.106 gTSS/g COD eliminated was obtained.

  16. Treatment performances of French constructed wetlands: results from a database collected over the last 30 years.

    Science.gov (United States)

    Morvannou, A; Forquet, N; Michel, S; Troesch, S; Molle, P

    2015-01-01

    Approximately 3,500 constructed wetlands (CWs) provide raw wastewater treatment in France for small communities (Built during the past 30 years, most consist of two vertical flow constructed wetlands (VFCWs) in series (stages). Many configurations exist, with systems associated with horizontal flow filters or waste stabilization ponds, vertical flow with recirculation, partially saturated systems, etc. A database analyzed 10 years earlier on the classical French system summarized the global performances data. This paper provides a similar analysis of performance data from 415 full-scale two-stage VFCWs from an improved database expanded by monitoring data available from Irstea and the French technical department. Trends presented in the first study are confirmed, exhibiting high chemical oxygen demand (COD), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN) removal rates (87%, 93% and 84%, respectively). Typical concentrations at the second-stage outlet are 74 mgCOD L(-1), 17 mgTSS L(-1) and 11 mgTKN L(-1). Pollutant removal performances are summarized in relation to the loads applied at the first treatment stage. While COD and TSS removal rates remain stable over the range of applied loads, the spreading of TKN removal rates increases as applied loads increase.

  17. Application of electrochemical technology for removing petroleum hydrocarbons from produced water using lead dioxide and boron-doped diamond electrodes.

    Science.gov (United States)

    Gargouri, Boutheina; Gargouri, Olfa Dridi; Gargouri, Bochra; Trabelsi, Souhel Kallel; Abdelhedi, Ridha; Bouaziz, Mohamed

    2014-12-01

    Although diverse methods exist for treating polluted water, the most promising and innovating technology is the electrochemical remediation process. This paper presents the anodic oxidation of real produced water (PW), generated by the petroleum exploration of the Petrobras plant-Tunisia. Experiments were conducted at different current densities (30, 50 and 100 mA cm(-2)) using the lead dioxide supported on tantalum (Ta/PbO2) and boron-doped diamond (BDD) anodes in an electrolytic batch cell. The electrolytic process was monitored by the chemical oxygen demand (COD) and the residual total petroleum hydrocarbon [TPH] in order to know the feasibility of electrochemical treatment. The characterization and quantification of petroleum wastewater components were performed by gas chromatography mass spectrometry. The COD removal was approximately 85% and 96% using PbO2 and BDD reached after 11 and 7h, respectively. Compared with PbO2, the BDD anode showed a better performance to remove petroleum hydrocarbons compounds from produced water. It provided a higher oxidation rate and it consumed lower energy. However, the energy consumption and process time make useless anodic oxidation for the complete elimination of pollutants from PW. Cytotoxicity has shown that electrochemical oxidation using BDD could be efficiently used to reduce more than 90% of hydrocarbons compounds. All results suggest that electrochemical oxidation could be an effective approach to treat highly concentrated organic pollutants present in the industrial petrochemical wastewater and significantly reduce the cost and time of treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Application of Moringa Oleifera seed extract to treat coffee fermentation wastewater.

    Science.gov (United States)

    Garde, William K; Buchberger, Steven G; Wendell, David; Kupferle, Margaret J

    2017-05-05

    Wastewater generated from wet processing of coffee cherries degrades stream water quality downstream of processing mills and impacts human health. The widespread popularity of coffee as an export makes this a global problem, although the immediate impact is local. Approximately 40% of all coffee around the world is wet processed, producing wastewater rich in organic nutrients that can be hazardous to aquatic systems. Moringa Oleifera Seed Extract (MOSE) offers promise as a local and affordable "appropriate" coagulation technology for aiding in the treatment of coffee wastewater. Field research was conducted at the Kauai Coffee Company to investigate the application of MOSE to treat coffee fermentation wastewater (CFW). Coagulation tests were conducted at five pH CFW levels (3-7) and MOSE doses (0-4g/L). After settling, TSS, COD, nitrate, nitrite, total nitrogen, and pH of supernatant from each test were measured. MOSE reduced TSS, COD, nitrate, and nitrite in CFW to varying degrees dependent on pH and dose applied. TSS removal ranged from 8% to 54%. Insoluble COD removal ranged from 26% to 100% and total COD removal ranged from 1% to 25%. Nitrate and nitrite reduction ranged from 20% to 100%. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Use of native aquatic macrophytes in the reduction of organic matter from dairy effluents.

    Science.gov (United States)

    Queiroz, Rita de Cássia Souza de; Andrade, Rodrigo Santos; Dantas, Isadora Rosário; Ribeiro, Vinícius de Souza; Neto, Luciano Brito Rodrigues; Almeida Neto, José Adolfo de

    2017-08-03

    Considering the diversity and the unexplored potential of regional aquatic flora, this study aimed to identify and analyze the potential of native aquatic macrophytes to reduce the organic matter of dairy wastewater (DW) using experimental constructed wetlands. The dairy wastewater (DW) had an average chemical oxygen demand (COD) of 7414.63 mg/L and then was diluted to 3133.16 mg/L (D1) and to 2506.53 mg/L (D2). Total solids, COD, temperature, and pH analyses were performed, and the biochemical oxygen demand (BOD) was estimated from the COD values. The best performance in the reduction of the organic matter was observed for Polygonum sp. (87.5% COD and 79.6% BOD) and Eichhornia paniculata (90% COD and 83.7% BOD) at dilution D1, on the 8th day of the experiment. However, the highest total solids removal was observed for Polygonum sp. (32.2%), on the 4th day, at dilution D2. The total solid (TS) concentration has also increased starting from the 8th day of the experiment was observed which may have been due to the development of mosquito larvae and their mechanical removal by sieving, thus changing the steady state of the experimental systems. The macrophytes Polygonum sp. and E. paniculata were considered suitable for the reduction of organic matter of DW using constructed wetlands.

  20. Fishing gear-induced skin ulcerations in Baltic cod, Gadus morhua L

    DEFF Research Database (Denmark)

    Mellergaard, Stig; Bagge, O.

    1998-01-01

    In 1982 a high prevalence of skin ulcerations was observed in Baltic cod in the vicinity of the Danish island of Bornholm. In March the prevalence varied from G to 13%, and in May it had increased to between 26 and 48%. The ulcerations had a sequential development. The initial stage appeared...... from the nets, combined with bilateral occurrence of the ulcers, strongly indicates that the skin ulcers were induced by the fishing gear. Features of the pathology could be linked to the temporary retention of cod in trawl meshes....

  1. Threshold-dependent climate effects and high mortality limit recruitment and recovery of the Kattegat cod

    DEFF Research Database (Denmark)

    Lindegren, Martin; Eero, Margit

    2013-01-01

    Cod in the Kattegat is one of the most dramatic examples of stock collapse, where despite large management efforts, almost no signs of recovery have been observed. We investigate how multiple physical and biological factors could potentially influence recruitment and recovery of Kattegat cod, using...... non-additive threshold models. In contrast to previous studies on recruitment dynamics of Kattegat cod Gadus morhua, we found that recruitment variability may be explained by a combination of the size of the spawning stock and external conditions (i.e. sea surface temperature and oxygen concentrations...

  2. Biopretreatment of palm oil mill effluent by thermotolerant polymer-producing fungi

    Directory of Open Access Journals (Sweden)

    Masao Ukita

    2001-11-01

    Full Text Available Palm oil industry is one of the three major agro-industries in Southern Thailand and generates large quantities of effluent with high organic matter (BOD and COD values of 58,000 and 110,000 mg/l, respectively, total solids and suspended solids (70,000 and 40,000 mg/l, respectively, oil & grease (25,600 mg/l, and has a low pH (4.5. Conventional anaerobic ponding system is normally employed in palm oil mills to treat the effluent. To increase its efficiency, biopretreatment to remove the organic matter and oil & grease by thermotolerant polymer-producing fungi was investigated. The palm oil mill effluent (POME was treated by the two thermotolerant polymer-producing fungi, Rhizopus sp. ST4 and Rhizopus sp. ST29, at 45ºC under aseptic and septic conditions. Rhizopus sp. ST4 gave the same oil & grease removal (84.2% under both conditions but COD removal under septic condition (62.2% was 8.8% higher than that under aseptic condition (53.4%. On the contrary, Rhizopus sp. ST 29 under aseptic condition showed 11% and 25.4% higher oil & grease removal (91.4% and COD removal (66.0% than those under septic condition. Comparison between the two isolates under aseptic condition revealed that Rhizopus sp. ST29 exhibited higher oil & grease removal (91.4% as well as COD removal (66.0% than those of Rhizopus sp. ST4 (84.2% and 53.4%, respectively. Under septic condition, Rhizopus sp. ST4 gave higher oil & grease removal (84.2% and COD removal (62.2% than did Rhizopus sp. ST 29 (80.5 and 40.6%, respectively.

  3. Membrane processes for the reuse of car washing wastewater

    Directory of Open Access Journals (Sweden)

    Deniz Uçar

    2018-04-01

    Full Text Available This study investigates alternative treatments of car wash effluents. The car wash wastewater was treated by settling, filtration, and membrane filtration processes. During settling, total solid concentration decreased rapidly within the first 2 hours and then remained constant. Chemical oxygen demand (COD and conductivity were decreased by 10% and 4%, respectively. After settling, wastewater was filtered throughout a 100 μm filter. It was found that filtration had a negligible effect on COD removal. Finally, wastewater was filtered by four ultrafiltration membranes of varying molecular weight cutoff (MWCO (1, 5, 10 and 50 kDa and one nanofiltration membrane (NF270, MWCO = 200–400 Da. The permeate COD concentrations varied between 64.5 ± 3.2 and 85.5 ± 4.3 mg L−1 depending on UF pore size. When the NF270 nanofiltration membrane was used, the permeate COD concentration was 8.1 ± 0.4 mg L−1 corresponding to 97% removal. FeCl3 precipitation and activated carbon adsorption techniques were also applied to the retentate and 60–76% COD removals were obtained for activated carbon adsorption and FeCl3 precipitation, respectively.

  4. The effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration

    Directory of Open Access Journals (Sweden)

    Ali Reza Solaimany Nazar

    2016-04-01

    Full Text Available An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial TFC (thin film composite polyamide nanofilter. The effects of pH (6.5-8.5, pressure (4-10 bar, concentration of total ammonia nitrogen (1-9 mg/L, and florfenicol (0.2-5 mg/L on the removal efficiency of the nanofilter were studied at a constant 70% recovery rate. It was found that by increasing the pH within the range of 6.5 to 8.5, it enhanced the removal efficiency by up to 98% and 100% for total ammonia nitrogen and florfenicol, respectively. With an increase in pressure from 4 to 7 bar, the removal percentage increased and then, it decreased from 7 to 10 bar. The interactions factors did not have significant effects on the both pollutants removal efficiencies. To obtain optimal removal efficiencies, an experimental design and statistical analysis via the response surface method were adopted.

  5. Continuous removal and recovery of tellurium in an upflow anaerobic granular sludge bed reactor

    Energy Technology Data Exchange (ETDEWEB)

    Mal, Joyabrata, E-mail: joyabrata2006@gmail.com [UNESCO-IHE, Westvest 7, 2611 AX Delft (Netherlands); Nancharaiah, Yarlagadda V. [Biofouling and Biofilm Processes Section, Water and Steam Chemistry Division, Bhabha Atomic Research Centre, Kalpakkam, 603102, Tamil Nadu (India); Homi Bhabha National Institute, Anushakti Nagar Complex, Mumbai 400094 (India); Maheshwari, Neeraj [CNRS UMR 7338, BMBI University de Technologie Compiegne, 60200 Compiegne (France); Hullebusch, Eric D. van [UNESCO-IHE, Westvest 7, 2611 AX Delft (Netherlands); Université Paris-Est, Laboratoire Géomatériaux et Environnement (LGE), EA 4508, UPEM, 77454, Marne-la-Vallée (France); Lens, Piet N.L. [UNESCO-IHE, Westvest 7, 2611 AX Delft (Netherlands); Department of Chemistry and Bioengineering, Tampere University of Technology, P.O-Box 541, Tampere (Finland)

    2017-04-05

    Highlights: • Tellurite bioreduction coupled to recovery of biogenic Te(0) nanocrystals. • First report on continuous tellurite removal in a UASB reactor. • Biogenic Te(0) was mainly associated with loosely-bound EPS of granular sludge. • Repeated exposure to tellurite caused compositional changes in the EPS matrix. - Abstract: Continuous removal of tellurite (TeO{sub 3}{sup 2−}) from synthetic wastewater and subsequent recovery in the form of elemental tellurium was studied in an upflow anaerobic granular sludge bed (UASB) reactor operated at 30 °C. The UASB reactor was inoculated with anaerobic granular sludge and fed with lactate as carbon source and electron donor at an organic loading rate of 0.6 g COD L{sup −1} d{sup −1}. After establishing efficient and stable COD removal, the reactor was fed with 10 mg TeO{sub 3}{sup 2−} L{sup −1} for 42 d before increasing the influent concentration to 20 mg TeO{sub 3}{sup 2−} L{sup −1}. Tellurite removal (98 and 92%, respectively, from 10 and 20 mg Te L{sup −1}) was primarily mediated through bioreduction and most of the removed Te was retained in the bioreactor. Characterization using XRD, Raman spectroscopy, SEM-EDX and TEM confirmed association of tellurium with the granular sludge, typically in the form of elemental Te(0) deposits. Furthermore, application of an extracellular polymeric substances (EPS) extraction method to the tellurite reducing sludge recovered up to 78% of the tellurium retained in the granular sludge. This study demonstrates for the first time the application of a UASB reactor for continuous tellurite removal from tellurite-containing wastewater coupled to elemental Te(0) recovery.

  6. Variations in the microbial log reduction curves of irradiated cod fillets, shrimp, and their respective homogenates

    International Nuclear Information System (INIS)

    Green, J.H.; Kaylor, J.D.

    1977-01-01

    When cod (Gadus morhua morhua) and headless white shrimp (Penaeus setiferus) were gamma irradiated with a series of low-ionizing radiation doses, a ''shoulder(s)'' was observed in the graph (log microbial counts versus dose) in the approximate range of 25 to 75 krads. When the microbiological survivors were differentiated into total counts, proteolytic and pseudomonad-type bacteria, it was observed that the pseudomonad-type bacteria were rapidly destroyed by 25 krads and that proteolytic bacteria were destroyed at a faster rate than the rest of the microorganisms. When cod fillets and shrimp were compared with their respective homogenates and irradiated at doses of 0, 10, 20, 30, 40, 50, 60, 80, 100, 150, 200, and 300 krads, the homogenates did not exhibt the characteristic shoulders. A further experiment was designed to test surface versus uniform dispersion of microorganisms on/in gelatin disks subject to low doses of irradiation. Differences were found that may explain the observed differences between solid food materials such as fish fillets and shrimp and their homogenates

  7. Removal of arsenic and COD from industrial wastewaters by electrocoagulation

    Directory of Open Access Journals (Sweden)

    H. POIROT

    2011-08-01

    Full Text Available The paper deals with the treatment of arsenic-containing industrial wastewaters by electrocoagulation. The waste issued from a paper mill industry downstream of the biological treatment by activated sludge was enriched with arsenic salts for the purpose of investigation of the treatment of mixed pollution. First, the treatment of single polluted waters, i.e. containing either the regular organic charge from the industrial waste or arsenic salts only, was studied. In the case of arsenic-containing waters, a broad selection of experimental data available in the literature was compiled and interpreted using an adsorption model developed previously. The same technique was used in the case of industrial waste. Arsenic-enriched paper mill wastewaters with various amounts of As salts were then treated by electrocoagulation with Fe electrodes. The set of data obtained were interpreted by a model developed on the basis of the separate models. The agreement between predicted and experimental variations of the As concentrations ranging from 0.3 µg/L to 730 µg/L showed that both the organic matter and As salt can be removed from the liquid independently from each other.

  8. Spatio-temporal dynamics of a fish predator: Density-dependent and hydrographic effects on Baltic Sea cod population.

    Directory of Open Access Journals (Sweden)

    Valerio Bartolino

    Full Text Available Understanding the mechanisms of spatial population dynamics is crucial for the successful management of exploited species and ecosystems. However, the underlying mechanisms of spatial distribution are generally complex due to the concurrent forcing of both density-dependent species interactions and density-independent environmental factors. Despite the high economic value and central ecological importance of cod in the Baltic Sea, the drivers of its spatio-temporal population dynamics have not been analytically investigated so far. In this paper, we used an extensive trawl survey dataset in combination with environmental data to investigate the spatial dynamics of the distribution of the Eastern Baltic cod during the past three decades using Generalized Additive Models. The results showed that adult cod distribution was mainly affected by cod population size, and to a minor degree by small-scale hydrological factors and the extent of suitable reproductive areas. As population size decreases, the cod population concentrates to the southern part of the Baltic Sea, where the preferred more marine environment conditions are encountered. Using the fitted models, we predicted the Baltic cod distribution back to the 1970s and a temporal index of cod spatial occupation was developed. Our study will contribute to the management and conservation of this important resource and of the ecosystem where it occurs, by showing the forces shaping its spatial distribution and therefore the potential response of the population to future exploitation and environmental changes.

  9. Location of and post-mortem changes in some cytoskeletal proteins in pork and cod muscle

    DEFF Research Database (Denmark)

    Morrison, E.H.; Bremner, Allan; Purslow, P.P.

    2000-01-01

    The cytoskeletal proteins actin, nebulin, spectrin, desmin, vinculin and talin were labelled immunohistochemically in sections of muscle from commercially available pigs and cod (Gadus morhua) taken pre-rigor and from samples stored for several days. Actin, nebulin and spectrin gave similar...... labelling patterns in both pork and cod muscle which remained the same in stored samples. Desmin was intensely labelled at the cell boundaries and within the body of the cells in both pork and cod in the initial and the stored samples. Vinculin was readily labelled in pork muscle but showed only diffuse...... labelling in fish. Labelling for talin in pork muscle was intense at the sarcolemma but was not present in samples stored for 4 days. In contrast, the label for talin was concentrated at the myotendinous junction of the cod muscle throughout the storage period. These are the first reports of the detection...

  10. Host size-dependent anisakid infection in Baltic cod Gadus morhua associated with differential food preferences

    DEFF Research Database (Denmark)

    Zuo, Shaozhi; Huwer, Bastian; Bahlool, Qusay

    2016-01-01

    A significant increase in the infection level of Baltic cod Gadus morhua with the anisakid nematode larvae Contracaecum osculatum and Pseudoterranova decipiens has been recorded during recent years due to the expanding local population of grey seals Halichoerus grypus, which act as final hosts......). A third nematode Hysterothylacium aduncum was rarely found. The study indicates that the prey animals for large cod act as transport hosts for the parasite larvae. Analyses of stomach contents of cod caught in the same area (2007-2014) showed that small benthic organisms (including polychaetes Harmothoë...... suggest that the C. osculatum life cycle in the Baltic Sea includes grey seals as final hosts, sprat as the first transport host and cod as second transport host. It may be speculated that sprat obtain infection by feeding on copepods and/or cladocerans, which could serve as the first intermediate hosts...

  11. Contracaecum osculatum and other anisakid nematodes in grey seals and cod in the Baltic Sea

    DEFF Research Database (Denmark)

    Zuo, S; Kania, P W; Mehrdana, F

    2018-01-01

    Populations of grey seals (Halichoerus grypus), sprats (Sprattus sprattus) and cod (Gadus morhua) in the Baltic Sea are relatively stationary. The present work, applying classical and molecular helminthological techniques, documents that seals and cod also share a common parasite, the anisakid...... nematode Contracaecum osculatum, which uses seals as the final host and fish as transport hosts. Sequencing mitochondrial genes (COX1 and COX2) in adult worms from seals and third-stage larvae from livers of Baltic fish (sprats and cod), showed that all gene variants occur in both seals and fish. Other...... anisakid nematodes Pseudoterranova decipiens and Anisakis simplex are also found in both seals and cod in the Baltic Sea, but at much lower rates. The Baltic grey seal population was left at a critically low level (comprising a few hundred individuals) during the latter part of the 20th century, but since...

  12. Stable isotope evidence for late medieval (14th-15th C origins of the eastern Baltic cod (Gadus morhua fishery.

    Directory of Open Access Journals (Sweden)

    David C Orton

    Full Text Available Although recent historical ecology studies have extended quantitative knowledge of eastern Baltic cod (Gadus morhua exploitation back as far as the 16th century, the historical origin of the modern fishery remains obscure. Widespread archaeological evidence for cod consumption around the eastern Baltic littoral emerges around the 13th century, three centuries before systematic documentation, but it is not clear whether this represents (1 development of a substantial eastern Baltic cod fishery, or (2 large-scale importation of preserved cod from elsewhere. To distinguish between these hypotheses we use stable carbon and nitrogen isotope analysis to determine likely catch regions of 74 cod vertebrae and cleithra from 19 Baltic archaeological sites dated from the 8th to the 16th centuries. δ(13C and δ(15N signatures for six possible catch regions were established using a larger sample of archaeological cod cranial bones (n = 249. The data strongly support the second hypothesis, revealing widespread importation of cod during the 13th to 14th centuries, most of it probably from Arctic Norway. By the 15th century, however, eastern Baltic cod dominate within our sample, indicating the development of a substantial late medieval fishery. Potential human impact on cod stocks in the eastern Baltic must thus be taken into account for at least the last 600 years.

  13. Stability of compounded trilostane suspension in cod liver oil.

    Science.gov (United States)

    Crosby, Jesse; Brown, Stacy

    2017-10-01

    Trilostane is a synthetic steroid analog used to treat canine hyperadrenocorticism. For small dogs, the dose found in commercially available dosage forms of trilostane is sometimes too high. Compounding trilostane in a liquid diluent provides an option for more precise dosing and adjustments, and can be easier to administer, versus a tablet or capsule. Trilostane suspends well in cod liver oil, which is generally palatable to dogs. The stability of a compounded trilostane suspension in cod liver oil stored at room temperature was investigated for 90 days. Compounded trilostane retained stability, defined as maintaining 90-105% labeled value, for 60 days when stored in amber glass bottles. However, drug potency fell >10% below the labeled value when stored in amber plastic bottles after 7 days. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Improvement of anaerobic digestion performance by continuous nitrogen removal with a membrane contactor treating a substrate rich in ammonia and sulfide.

    Science.gov (United States)

    Lauterböck, B; Nikolausz, M; Lv, Z; Baumgartner, M; Liebhard, G; Fuchs, W

    2014-04-01

    The effect of reduced ammonia levels on anaerobic digestion was investigated. Two reactors were fed with slaughterhouse waste, one with a hollow fiber membrane contractor for ammonia removal and one without. Different organic loading rates (OLR) and free ammonia and sulfide concentrations were investigated. In the reactor with the membrane contactor, the NH4-N concentration was reduced threefold. At a moderate OLR (3.1 kg chemical oxygen demand - COD/m(3)/d), this reactor performed significantly better than the reference reactor. At high OLR (4.2 kg COD/m(3)/d), the reference reactor almost stopped producing methane (0.01 Nl/gCOD). The membrane reactor also showed a stable process with a methane yield of 0.23 Nl/g COD was achieved. Both reactors had predominantly a hydrogenotrophic microbial consortium, however in the membrane reactor the genus Methanosaeta (acetoclastic) was also detected. In general, all relevant parameters and the methanogenic consortium indicated improved anaerobic digestion of the reactor with the membrane. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Impact of hypoxia on consumption of Baltic cod in a multispecies stock assessment context

    DEFF Research Database (Denmark)

    Teschner, E.C.; Kraus, G.; Neuenfeldt, Stefan

    2010-01-01

    The Baltic Sea is characterised by a heterogeneous oceanographic environment. The deep water layers forming the habitat of Baltic cod (Gadus morhua callarias L.) are subjected to frequently occurring pronounced anoxic conditions. Adverse oxygen conditions result in physiological stress for organi......The Baltic Sea is characterised by a heterogeneous oceanographic environment. The deep water layers forming the habitat of Baltic cod (Gadus morhua callarias L.) are subjected to frequently occurring pronounced anoxic conditions. Adverse oxygen conditions result in physiological stress...... for organisms living under these conditions. For cod e.g. a direct relationship between oxygen availability and food intake with a decreasing ingestion rate at hypoxia could be revealed. In the present study, the effects of oxygen deficiency on consumption rates were investigated and how these translate...... to stock size estimates in multi-species models. Based on results from laboratory experiments, a model was fitted to evacuation rates at different oxygen levels and integrated into the existing consumption model for Baltic cod. Individual mean oxygen corrected consumption rates were 0.1–10.9% lower than...

  16. Determination and identification of hydrophilic and hydrophobic arsenic species in methanol extract of fresh cod liver by RP-HPLC with simultaneous ICP-MS and ESI-Q-TOF-MS detection.

    Science.gov (United States)

    Arroyo-Abad, Uriel; Lischka, Susanne; Piechotta, Christian; Mattusch, Jürgen; Reemtsma, Thorsten

    2013-12-01

    The present study was focused on the determination and identification of arsenic species in methanolic extracts of cod liver. Arsenic species were fractionated and the fractions analysed by RP-HPLC-ICP-MS coupled with ESI-Q-TOF-MS. The total concentration of arsenic in the fresh cod liver was analysed by ICP-MS to be 1.53±0.02 mg As kg(-1)w.w. and the extraction recovery was ca. 100% and the column recovery >93%. Besides polar inorganic and methylated arsenic species (>70%) more hydrophobic arsenic-containing fatty acids and hydrocarbons occurred. Based on the mass spectrometric data proposals for molecular structures were elaborated for 20 of the organic As species included 10 arsenic-containing fatty acids (AsFA) and an arsenic-containing hydrocarbon (AsHC) mentioned for the first time in fresh cod liver. Arsenobetaine was found as main water-soluble arsenic compound in cod liver followed by higher molecular mass arsenic-containing fatty acids and hydrocarbons. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Decolorization and removal of cod and bodfrom raw and biotreated textile dye bath effluent through advanced oxidation processes (AOPS

    Directory of Open Access Journals (Sweden)

    A. Muhammad

    2008-09-01

    Full Text Available In this paper, a comparative study of the treatment of raw and biotreated (upflow anaerobic sludge blanket, UASB textile dye bath effluent using advanced oxidation processes (AOPs is presented. The AOPs applied on raw and biotreated textile dye bath effluent, after characterization in terms of COD, colour, BOD and pH, were ozone, UV, UV/H2O2 and photo-Fenton. The decolorization of raw dye bath effluent was 58% in the case of ozonation. However it was 98% in the case of biotreated dye bath effluent when exposed to UV/H2O2. It is, therefore, suggested that a combination of biotreatment and AOPs be adopted to decolorize dye bath effluent in order to make the process more viable and effective. Biodegradability was also improved by applying AOPs after biotreatment of dye bath effluent.

  18. Long-chain perfluoroalkyl carboxylic acids in Pacific cods from coastal areas in northern Japan: A major source of human dietary exposure

    International Nuclear Information System (INIS)

    Fujii, Yukiko; Sakurada, Tsukasa; Harada, Kouji H.; Koizumi, Akio; Kimura, Osamu; Endo, Tetsuya; Haraguchi, Koichi

    2015-01-01

    This study investigates perfluoroalkyl carboxylic acids (PFCAs) contamination of edible fish muscle from Japanese coastal waters. The concentrations of PFCAs with 8–14 carbon atoms (C8–C14) in Pacific cods in Hokkaido, Japan were 51 (median: pg/g-wet weight) for C8, 93 for C9, 99 for C10, 746 for C11, 416 for C12, 404 for C13, and 93 for C14. The levels of C9–C14 PFCAs in fish were strongly correlated to each other, but not to C8 and the other chlorinated persistent organic pollutants, indicating that C9–C14 PFCAs have a different emission source and/or bioaccumulation mechanism. The relative ratios between estimated PFCAs intake through fish consumption and the reported total dietary exposure of PFCAs were less than 1 for C8 to C9, but were more than 1 for C10 to C14. This result strongly suggests that fish consumption is a significant source of human dietary exposure to C10–C14 PFCAs. - Highlights: • Perfluoroalkyl carboxylic acids were detected in edible cod fish from Japanese coastal waters. • The levels of long-chain PFCAs in fish were independent from those of C8 and other POPs. • Long chain PFCAs intake through fish and the reported total dietary exposure were comparable. • Sea fish such as Pacific cod may be a significant human dietary source of long-chain PFCAs. - Sea fish are a significant source of long-chain perfluoroalkyl carboxylic acids for the Japanese population

  19. Evaluation of the treatability of a winery distillery (vinasse) wastewater by UASB, anoxic-aerobic UF-MBR and chemical precipitation/adsorption.

    Science.gov (United States)

    Petta, Luigi; De Gisi, Sabino; Casella, Patrizia; Farina, Roberto; Notarnicola, Michele

    2017-10-01

    A multi-stage pilot-scale treatment cycle consisting of an Upflow Anaerobic Sludge Blanket reactor (UASB) followed by an anoxic-aerobic Ultra Filtration Membrane Bio Reactor (UF-MBR) and a post treatment based on chemical precipitation with lime or adsorption on Granular Activated Carbons (GAC), was applied in order to evaluate the treatment feasibility of a real winery distillery wastewater at laboratory and bench scale. The wastewater was classified as high strength with acidic pH (3.8), and concentrations of 44,600, 254, 604 and 660 mg/l for COD tot , total nitrogen, total phosphorous and phenols, respectively. The UASB reactor was operated at Organic Loading Rates (OLR) in the range 3.0-11.5 kgCOD tot /m 3 /d achieving treatment efficiency up to 97%, with an observed methane production of 340 L of CH 4 /kgCOD. The MBR system was operated with an organic load in the range 0.070-0.185 kgCOD/kgVSS/d, achieving a removal up to 48%, 67% and 65% of the influent COD, total nitrogen and phenols, respectively. The combination of UASB and UF-MBR treatment units was not effective in phosphate and colour removal assigning to further chemical precipitation and adsorption processes, respectively, their complete removal in order to comply with legal standards for wastewater discharge. Subsequently, the optimization of the investigated treatment chain was assessed by applying a chemical precipitation step upstream and downstream the UASB reactor, and a related treatment unit cost assessment is presented in view of a further technological scale-up. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. COD fractions changes in the SBR-type reactor treating municipal wastewater with controlled percentage of dairy sewage

    Directory of Open Access Journals (Sweden)

    Struk-Sokołowska Joanna

    2017-01-01

    Full Text Available The aim of study was to investigate the influence of percentage of dairy wastewater in the municipal wastewater on the changes of COD fractions during the cycle of SBR-type reactor. The scope of the research included physicochemical analyses of municipal wastewater without dairy wastewater, dairy wastewater, mixture of municipal and dairy wastewater as well as treated sewage. Both the concentrations and the proportions between COD fractions changed in the SBR cycle. In raw municipal and dairy wastewater - XS, insoluble hardly bio-degradable fraction of COD dominated (49.6 and 64.5% respectively. In treated wastewater SI, COD for dissolved compounds that are not biologically decomposed (inert (from 62.1 to 74.6% dominated, while XS fraction was from 19.1 to 24.4%. The consumption rate of organic compounds depended on the type of COD fraction, SBR cycle phase and the percentage of dairy wastewater. The highest rates of organic compounds consumption were noted in the phase of mixing. In the case of fraction SI, no differences in concentration in the SBR cycle time, were found. Concentration of COD in treated wastewater was from 34.8 to 58.9 mgO2·L-1 (efficiency wastewater treatment from 96.0 to 98.6%.

  1. Detection of Fish Bones in Cod Fillets by UV Illumination.

    Science.gov (United States)

    Wang, Sheng; Nian, Rui; Cao, Limin; Sui, Jianxin; Lin, Hong

    2015-07-01

    The presence of fish bones is now regarded as an important hazard in fishery products, and there is increasing demand for new analytical techniques to control it more effectively. Here, the fluorescent properties of cod bones under UV illumination were investigated, and the maximal wavelengths for excitation and emission were determined to be 320 nm and 515 nm, respectively, demonstrating significantly different fluorescence characteristics and much higher fluorescence intensity compared to those of fillet muscles. Based on the results, UV fluorescence-assisted candling for the detection of bones in fishery products was developed for the first time. Using cod fillets as samples, the detection ratio of this technique was calculated as 90.86%, significantly higher than that of traditional candling under daylight (76.78%). Moreover, the working efficiency of the new technique was about 26% higher than that of the traditional method. A UV fluorescence imaging framework was also developed, and a method for automatic identification of the fish bones in the cod fillets based on the linear discriminant analysis proposed by Fisher was preliminarily realized, but the detection ratio was demonstrated to be relatively poor compared to those of candling techniques. These results allow us to suggest UV-based methods as new and promising approaches for routine monitoring of bones in fishery products.

  2. The invasive ctenophore Mnemiopsis leidyi poses no direct threat to Baltic cod eggs and larvae

    DEFF Research Database (Denmark)

    Jaspers, Cornelia; Titelman, Josefin; Hansson, Lars Johan

    2011-01-01

    conducted laboratory incubation experimentsand video observations to quantify feeding rates on Baltic cod eggs and larvae. Ingestion rates increased with codlarvae concentrations up to 8 prey L21, beyond which ingestion remained constant. Neither Mnemiopsis size noregg concentration (1–16 prey L21) affected...... feeding rates on cod eggs. Observed feeding rates pooled from allexperiments conducted at nonsaturating prey concentrations were low, with the highest volume-specific clearanceon , 4.5-d-old yolk-sac larvae (0.05 6 0.02 L (mL Mnemiopsis)21 h21), and lower rates on 4.5–8-d-old larvae(0.02 6 0.02 L (m......L Mnemiopsis)21 h21) and eggs (0.02 6 0.03 L (mL Mnemiopsis)21 h21). When offered Artemiasalina and cod eggs simultaneously, Mnemiopsis passively selected against cod eggs. Video recordings showed thateggs did not trigger the capture response that Mnemiopsis shows toward motile prey, and ingested eggs were...

  3. The Impact of Microbial Ecology and Chemical Profile on the Enhanced Biological Phosphorus Removal (EBPR Process: A Case Study of Northern Wastewater Treatment Works, Johannesburg

    Directory of Open Access Journals (Sweden)

    Ilunga Kamika

    2014-03-01

    Full Text Available The impact of polyphosphate-accumulating organism (PAO and glycogen-accumulating organism (GAO populations as well as of the chemical profile on the performance of Unit-3 (open elutriation tanks and Unit-5 (covered elutriation tank of the City of Johannesburg Northern Wastewater Treatment Works was determined. Physicochemical parameters of wastewater samples were measured using standard methods. Bacterial diversity was determined using 16S rRNA gene amplicon pyrosequencing of the variable region V1-3. Results showed soluble COD concentrations from settled sewage for Unit-3 at 192.8 mg COD/L and for Unit-5 at 214.6 mg COD/L, which increased to 301.8 mg COD/L and 411.6 mg COD/L in the overflow from elutriation tanks and decreased to 170.9 mg COD/L and 256.3 mg COD/L at the division boxes, respectively. Both long-chain volatile fatty acids (heptanoic acid, isobutyric acid, 3-methylbutanoic acid, pentanoic acid, 4-methylpentanoic acid, methylheptanoic acid and short-chain volatile fatty acids (acetic acid, propionic acid, isobutyric acid were present within concentration ranges of 17.19 mg/L to 54.98 mg/L and 13.64 mg/L to 87.6 mg/L for Unit 3 and 38.61 mg/L to58.85 mg/L and 21.63 mg/L to 92.39 mg/L for Unit 5, respectively. In the secondary settling tanks, the phosphate-removal efficiency in Unit-5 appeared to be slightly higher (0.08 mg P/L compared to that of Unit-3 (0.11 mg P/L. The average DO concentrations (2.1 mg/L and 2.2 mg/L as well as the pH values (pH 7 to pH 7.5 were found to be slightly higher in Unit-5 in the aerobic zones. The high presence of PAOs in the bioreactors (Unit-5: Dechloromonas (14.96%, Acinetobacter (6.3%, Zoogloea (4.72% in the anaerobic zone and Dechloromonas (22.37 % in the aerobic zone; Unit-3: Dechloromonas (37.25% in the anaerobic zone and Dechloromonas (23.97% in the aerobic zone confirmed the phosphate-removal efficiencies of both units. Negligible GAOs were found in the aerobic zones (Defluviicoccus spp.: 0

  4. The impact of microbial ecology and chemical profile on the enhanced biological phosphorus removal (EBPR) process: a case study of Northern Wastewater Treatment Works, Johannesburg.

    Science.gov (United States)

    Kamika, Ilunga; Coetzee, Martie; Mamba, Bhekie Brilliance; Msagati, Titus; Momba, Maggy N B

    2014-03-10

    The impact of polyphosphate-accumulating organism (PAO) and glycogen-accumulating organism (GAO) populations as well as of the chemical profile on the performance of Unit-3 (open elutriation tanks) and Unit-5 (covered elutriation tank) of the City of Johannesburg Northern Wastewater Treatment Works was determined. Physicochemical parameters of wastewater samples were measured using standard methods. Bacterial diversity was determined using 16S rRNA gene amplicon pyrosequencing of the variable region V1-3. Results showed soluble COD concentrations from settled sewage for Unit-3 at 192.8 mg COD/L and for Unit-5 at 214.6 mg COD/L, which increased to 301.8 mg COD/L and 411.6 mg COD/L in the overflow from elutriation tanks and decreased to 170.9 mg COD/L and 256.3 mg COD/L at the division boxes, respectively. Both long-chain volatile fatty acids (heptanoic acid, isobutyric acid, 3-methylbutanoic acid, pentanoic acid, 4-methylpentanoic acid, methylheptanoic acid) and short-chain volatile fatty acids (acetic acid, propionic acid, isobutyric acid) were present within concentration ranges of 17.19 mg/L to 54.98 mg/L and 13.64 mg/L to 87.6 mg/L for Unit 3 and 38.61 mg/L to58.85 mg/L and 21.63 mg/L to 92.39 mg/L for Unit 5, respectively. In the secondary settling tanks, the phosphate-removal efficiency in Unit-5 appeared to be slightly higher (0.08 mg P/L) compared to that of Unit-3 (0.11 mg P/L). The average DO concentrations (2.1 mg/L and 2.2 mg/L) as well as the pH values (pH 7 to pH 7.5) were found to be slightly higher in Unit-5 in the aerobic zones. The high presence of PAOs in the bioreactors (Unit-5: Dechloromonas (14.96%), Acinetobacter (6.3%), Zoogloea (4.72%) in the anaerobic zone and Dechloromonas (22.37 %) in the aerobic zone; Unit-3: Dechloromonas (37.25%) in the anaerobic zone and Dechloromonas (23.97%) in the aerobic zone) confirmed the phosphate-removal efficiencies of both units. Negligible GAOs were found in the aerobic zones (Defluviicoccus spp.: 0.33% for

  5. Treatment of real paracetamol wastewater by fenton process

    Directory of Open Access Journals (Sweden)

    Dalgic Gamze

    2017-01-01

    Full Text Available The study investigated the pretreatment of real paracetamol (PCT wastewater of a pharmaceutical industry by Fenton process. At the best experimental conditions (COD/H2O2 = 1/1, Fe+2/H2O2 = 1/70, settling method:centrifuging, pH 6 at settling step, 92.7, 92.7, 95.5, 99.1, 99.9 and 99.4% of chemical oxygen demand (COD, total organic carbon (TOC, 5-day biological oxygen demand (BOD5, PCT, para-amino phenol (PAP and aniline were removed, respectively. Changes in the concentrations of these parameters were also investigated for both oxidation and settling steps of Fenton process. It was found that COD and TOC were removed at the settling step (precipitation whereas PCT, PAP and aniline were removed at the oxidation step. Mass balance calculations were also studied to show the mass distributions of COD in different phases (gas + foam, effluent and sludge. Fenton process was found as an effective method for the pretreatment of real PCT wastewater for discharging in a determined collective treatment plant.

  6. Linking lipid dynamics with the reproductive cycle in Baltic cod Gadus morhua

    DEFF Research Database (Denmark)

    Røjbek, Maria; Jacobsen, Charlotte; Tomkiewicz, Jonna

    2012-01-01

    ovaries and decreased in late maturing and spawning fish, most likely due to their antioxidant protection activity. The fatty acid composition of cod liver reflected its clupeid prey. The ratio of 18:1n-9 to DHA was almost twice as high in sprat as in herring and indicated the ratio of sprat and herring...... with cod ovarian development in the central Baltic Sea, and may be associated with the delay in spawning and affect egg and larval survival; however, this needs further verification in experimental studies....

  7. Use of Low-cost Adsorbents to Chlorophenols and Organic Matter Removal of Petrochemical Wastewater

    Directory of Open Access Journals (Sweden)

    Aretha Moreira de Oliveira

    2013-11-01

    Full Text Available The removal of 2,4 diclorophenol (2,4-DCF and 2,4,6 trichlorophenol (2,4,6 TCF present in  petrochemical wastewater was evaluated using low-cost adsorbents, such as chitin, chitosan and coconut shells. Batch studies showed that the absorption efficiency for 2,4 DCF and 2,4,6 TCF follow the order: chitosan > chitin > coconut shells. Langmuir and Freundlich models have been applied to experimental isotherms data, to better understand the adsorption mechanisms. Petrochemical wastewater treatment with fixed bed column system using chitinous adsorbents showed a removal of COD (75% , TOG (90% and turbidity (74-89%.

  8. Prediction of selectivity from morphological conditions: Methodology and a case study on cod (Gadus morhua)

    DEFF Research Database (Denmark)

    Herrmann, Bent; Krag, Ludvig Ahm; Frandsen, Rikke

    2009-01-01

    The FISHSELECT methodology. tools, and software were developed and used to measure the morphological parameters that determine the ability of cod to penetrate different mesh types, sizes, and openings. The shape of one cross-section at the cod's head was found to explain 97.6% of the mesh...

  9. Use of Fenton oxidation to improve the biodegradability of a pharmaceutical wastewater

    International Nuclear Information System (INIS)

    Tekin, Huseyin; Bilkay, Okan; Ataberk, Selale S.; Balta, Tolga H.; Ceribasi, I. Haluk; Sanin, F. Dilek; Dilek, Filiz B.; Yetis, Ulku

    2006-01-01

    The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H 2 O 2 /Fe 2+ was 150-250. At H 2 O 2 /Fe 2+ ratio of 155, 0.3 M H 2 O 2 and 0.002 M Fe 2+ , provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8 m 3 and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal

  10. Removal of total suspended solid by natural coagulant derived from cassava peel waste

    Science.gov (United States)

    Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.

    2018-04-01

    The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.

  11. Harvesting Atlantic Cod under Climate Variability

    Science.gov (United States)

    Oremus, K. L.

    2016-12-01

    Previous literature links the growth of a fishery to climate variability. This study uses an age-structured bioeconomic model to compare optimal harvest in the Gulf of Maine Atlantic cod fishery under a variable climate versus a static climate. The optimal harvest path depends on the relationship between fishery growth and the interest rate, with higher interest rates dictating greater harvests now at the cost of long-term stock sustainability. Given the time horizon of a single generation of fishermen under assumptions of a static climate, the model finds that the economically optimal management strategy is to harvest the entire stock in the short term and allow the fishery to collapse. However, if the biological growth of the fishery is assumed to vary with climate conditions, such as the North Atlantic Oscillation, there will always be pulses of high growth in the stock. During some of these high-growth years, the growth of the stock and its economic yield can exceed the growth rate of the economy even under high interest rates. This implies that it is not economically optimal to exhaust the New England cod fishery if NAO is included in the biological growth function. This finding may have theoretical implications for the management of other renewable yet exhaustible resources whose growth rates are subject to climate variability.

  12. Specific inhibition of Photobacterium phosphoreum extends the shelf life of modified-atmosphere-packed cod fillets

    DEFF Research Database (Denmark)

    Dalgaard, Paw; Munoz, L.G.; Mejlholm, Ole

    1998-01-01

    rather than the development of a new product. In naturally contaminated modified-atmosphere-packed cod fillets, 500 ppm Na(2)CaEDTA reduced the growth rate of P. phosphoreum by 40% and shelf life was increased proportionally by 40%, from 15 to 17 days to 21 to 23 days at 0 degrees C. In aerobically...... stored cod fillets other microorganisms were responsible for spoilage and Na2CaEDTA had no effect on shelf Life. The extension of the shelf life of modified-atmosphere-packed cod therefore was a result of the reduced growth of P. phosphoreum and no other microbial or nonmicrobial spoilage reactions...

  13. Freshness assessment of thawed and chilled cod fillets packed in modified atmosphere using near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Bøknæs, Niels; Jensen, K.N.; Andersen, Charlotte Møller

    2002-01-01

    Near-infrared reflectance (NIR) spectra was recorded of 105 samples of cod mince prepared from chill stored thawed cod fillets of varying quality in modified atmosphere packaging (MAP). Traditional chemical, physical, microbiological and sensory quality methods developed for assessing fresh fish...

  14. Characterization of dissolved organic matter in landfill leachate during the combined treatment process of air stripping, Fenton, SBR and coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, ZhiPing, E-mail: liulqs@163.com [Key Laboratory of Three Gorges Reservoir Region’s Eco-Environment, Ministry of Education, Chongqing University, Chongqing 400045 (China); Faculty of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400020 (China); Wu, WenHui; Shi, Ping [Faculty of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400020 (China); Guo, JinSong [Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400045 (China); Cheng, Jin [Faculty of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400020 (China)

    2015-07-15

    Highlights: • DOM fractions spectra analysis during the whole treatment process. • Efficient method was achieved to remove organic matters in landfill leachate. • Molecular weight distribution and fractions were discussed. - Abstract: A combined treatment process of air stripping + Fenton + sequencing batch reactor (SBR)+ coagulation was performed to remove the pollutants in landfill leachate. Molecular weight (MW) distribution and fractions of dissolved organic matter (DOM) were discussed to study the characteristics. The experiment showed that the removal rate of chemical oxygen demand (COD), five day biological oxygen demand (BOD{sub 5}) and ammonia nitrogen (NH{sub 3}−N) by the combined process were 92.8%, 87.8% and 98.0%, respectively. Humic acid (HA) and fulvic acid (FA) were the main fractions in raw leachate with 81.8% of the total COD concentration, while hydrophilic organic matter (HyI) was the dominant fraction in the final effluent of the combined process with 63.5% of the total COD concentration. After the combined treatment process, the removal rate of DOM and fractions HA, FA, HyI were 91.9%, 97.1%, 95.8% and 71.7%, respectively. Organic matters of MW < 2 k and MW > 100 k were removed with 90.5% and 97.9% COD concentration after the treatment. The ultraviolet–visible spectra (UV–vis), Fourier transform infrared spectra (FTIR) and three-dimensional excitation-emission matrices spectra (EEMs) indicated that benzene materials and phenol compounds were preferentially removed in air stripping. High MW matters, aromatic rings, conjugated moieties and some functional groups were mainly removed by Fenton. While small MW fractions, carboxylic acids, alcohols and protein-like materials were preferentially biodegraded via SBR. Fulvic-like and humic-like materials were mainly destroyed via Fenton oxidation and coagulation.

  15. Hazard Analysis and identification of Critical Control Points of collagen extraction from cod by-products

    NARCIS (Netherlands)

    Aalberts, C.H.J.

    2004-01-01

    The aim of the European research project “UTILISATION AND STABILISATION OF BY-PRODUCTS FROM COD SPECIES” (QLK1-CT-2000-01017 QLRT-2001-02829) is to investigate whether collagen from fish by-products could serve as an important raw material in high quality food. Since Atlantic cod is a major

  16. Cortisol levels and expression of selected stress- and apoptosis-related genes in the embryos of Atlantic cod, Gadus morhua following short-term exposure to air

    DEFF Research Database (Denmark)

    Marlowe, Christopher; Caipang, A.; Fagutao, Ferdinand F.

    2015-01-01

    Embryos (morula stage) of Atlantic cod, Gadus morhua L., were collected and subjected to air exposure for 2 min. followed by recovery at ambient conditions in the rearing container. Total immunoreactive cortisol and transcription of selected stress- and apoptosis-related genes of the embryos were...

  17. Total synthesis of cytochrome b562 by native chemical ligation using a removable auxiliary

    Science.gov (United States)

    Low, Donald W.; Hill, Michael G.; Carrasco, Michael R.; Kent, Stephen B. H.; Botti, Paolo

    2001-01-01

    We have completed the total chemical synthesis of cytochrome b562 and an axial ligand analogue, [SeMet7]cyt b562, by thioester-mediated chemical ligation of unprotected peptide segments. A novel auxiliary-mediated native chemical ligation that enables peptide ligation to be applied to protein sequences lacking cysteine was used. A cleavable thiol-containing auxiliary group, 1-phenyl-2-mercaptoethyl, was added to the α-amino group of one peptide segment to facilitate amide bond-forming ligation. The amine-linked 1-phenyl-2-mercaptoethyl auxiliary was stable to anhydrous hydrogen fluoride used to cleave and deprotect peptides after solid-phase peptide synthesis. Following native chemical ligation with a thioester-containing segment, the auxiliary group was cleanly removed from the newly formed amide bond by treatment with anhydrous hydrogen fluoride, yielding a full-length unmodified polypeptide product. The resulting polypeptide was reconstituted with heme and folded to form the functional protein molecule. Synthetic wild-type cyt b562 exhibited spectroscopic and electrochemical properties identical to the recombinant protein, whereas the engineered [SeMet7]cyt b562 analogue protein was spectroscopically and functionally distinct, with a reduction potential shifted by ≈45 mV. The use of the 1-phenyl-2-mercaptoethyl removable auxiliary reported here will greatly expand the applicability of total protein synthesis by native chemical ligation of unprotected peptide segments. PMID:11390992

  18. Mapping the spawning grounds of North Sea cod (Gadus morhua) by direct and indirect means.

    Science.gov (United States)

    Fox, Clive J; Taylor, Martin; Dickey-Collas, Mark; Fossum, Petter; Kraus, Gerd; Rohlf, Norbert; Munk, Peter; van Damme, Cindy J G; Bolle, Loes J; Maxwell, David L; Wright, Peter J

    2008-07-07

    Despite recent evidence for sub-stock structuring, North Sea cod are assessed as a single unit. As a consequence, knowledge of sub-stock trends is poor. In particular, there are no recent evaluations of which spawning grounds are active. Here we report results from the first ichthyoplankton survey to cover the whole North Sea. Also, this survey, conducted in 2004, was the first to make extensive use of DNA-based molecular methods to unambiguously identify early developmental stage cod eggs. We compare the findings from the plankton survey with estimated egg production inferred from the distribution of mature cod in contemporaneous trawl surveys. Results from both approaches were in general agreement and showed hot spots of egg production around the southern and eastern edges of the Dogger Bank, in the German Bight, the Moray Firth and to the east of the Shetlands. These areas broadly coincide with known spawning locations from the period 1940 to 1970. We were, however, unable to directly detect significant numbers of cod eggs at the historic spawning ground off Flamborough (northeast coast of England). The results demonstrate that most of the major spawning grounds of cod in the North Sea are still active but that some localized populations may have been reduced to the point where it is now difficult to detect the presence of eggs in the plankton.

  19. Treatment of high-strength synthetic sewage in a laboratory-scale upflow anaerobic sludge bed (UASB) with aerobic activated sludge (AS) post-treatment.

    Science.gov (United States)

    Banihani, Qais H; Field, Jim A

    2013-01-01

    Performance of a combined system up-flow anaerobic sludge blanket (UASB) followed by aerobic treatment activated sludge (AS) for removal of carbonaceous and nitrogenous contaminants at an average temperature of 25°C was investigated. The combined system was fed with high strength synthetic sewage having chemical oxygen demand (COD) of 2500 mg L(-1). The organic loading rate (OLR) of the UASB reactor was increased gradually from 1.1 to 3.8 gCOD L(r) (-1) d(-1). At steady state condition, the UASB reactor achieved removal efficiency up to 83.5% of total COD (COD(tot)), 74.0% of volatile fatty acid (VFA) and 94.0% of protein. The combined system performed an excellent organic removal pushing the overall removal efficiency of COD(tot), VFA and protein to 91.0%, 99.9% and 98.2%, respectively. When the OLR of the UASB increased to 4.4 g COD L(r) (-1) d(-1), the UASB was overloaded and; thus, its effluent quality deteriorated. In respect to nitrogen removal, both partial nitrification and complete nitrification took place in aerobic post-treatment. When the dissolved oxygen (DO) concentration was >2.0 mg L(-1), complete nitrification (period B) occurred with an average nitrification efficiency of 96.2%. The partial nitrification occurred due to high OLR to AS during the overloading event (period A) and when DO concentration was <2.0 mg L(-1) (period C). The maximum accumulated nitrite concentration in periods A, B and C were 90.0, 0.9 and 75.8 mg NO(-) (2) -N L(-1), respectively. The nitrogen balance results of periods A and C indicated that there was a discrepancy between the amount of ammonium nitrogen removed and the amount of oxidized nitrogen formed. This suggests the occurrence of simultaneous nitrification/denitrification (SND) in aerobic post-treatment.

  20. Eastern Baltic cod in distress: biological changes and challenges for stock assessment

    DEFF Research Database (Denmark)

    Eero, Margit; Hjelm, Joakim; Behrens, Jane

    2015-01-01

    The eastern Baltic (EB) cod (Gadus morhua) stock was depleted and overexploited for decades until the mid-2000s, when fishing mortality rapidly declined and biomass started to increase, as shown by stock assessments. These positive developments were partly assigned to effective management measures...... that the stock is in distress. In this study, we (i) summarize the knowledge of recent changes in cod biology and ecosystem conditions, (ii) describe the subsequent challenges for stock assessment, and (iii) highlight the key questions where answers are urgently needed to understand the present stock status...