WorldWideScience

Sample records for total carbon measurement

  1. Selection criteria for oxidation method in total organic carbon measurement.

    Science.gov (United States)

    Yoon, GeunSeok; Park, Sang-Min; Yang, Heuiwon; Tsang, Daniel C W; Alessi, Daniel S; Baek, Kitae

    2018-05-01

    During the measurement of total organic carbon (TOC), dissolved organic carbon is converted into CO 2 by using high temperature combustion (HTC) or wet chemical oxidation (WCO). However, the criteria for selecting the oxidation methods are not clear. In this study, the chemical structures of organic material were considered as a key factor to select the oxidation method used. Most non-degradable organic compounds showed a similar oxidation efficiency in both methods, including natural organic compounds, dyes, and pharmaceuticals, and thus both methods are appropriate to measure TOC in waters containing these compounds. However, only a fraction of the carbon in the halogenated compounds (perfluorooctanoic acid and trifluoroacetic acid) were oxidized using WCO, resulting in measured TOC values that are considerably lower than those determined by HTC. This result is likely due to the electronegativity of halogen elements which inhibits the approach of electron-rich sulfate radicals in the WCO, and the higher bond strength of carbon-halogen pairs as compared to carbon-hydrogen bonds, which results in a lower degree of oxidation of the compounds. Our results indicate that WCO could be used to oxidize most organic compounds, but may not be appropriate to quantify TOC in organic carbon pools that contain certain halogenated compounds. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. An improved method for quantitatively measuring the sequences of total organic carbon and black carbon in marine sediment cores

    Science.gov (United States)

    Xu, Xiaoming; Zhu, Qing; Zhou, Qianzhi; Liu, Jinzhong; Yuan, Jianping; Wang, Jianghai

    2018-01-01

    Understanding global carbon cycle is critical to uncover the mechanisms of global warming and remediate its adverse effects on human activities. Organic carbon in marine sediments is an indispensable part of the global carbon reservoir in global carbon cycling. Evaluating such a reservoir calls for quantitative studies of marine carbon burial, which closely depend on quantifying total organic carbon and black carbon in marine sediment cores and subsequently on obtaining their high-resolution temporal sequences. However, the conventional methods for detecting the contents of total organic carbon or black carbon cannot resolve the following specific difficulties, i.e., (1) a very limited amount of each subsample versus the diverse analytical items, (2) a low and fluctuating recovery rate of total organic carbon or black carbon versus the reproducibility of carbon data, and (3) a large number of subsamples versus the rapid batch measurements. In this work, (i) adopting the customized disposable ceramic crucibles with the microporecontrolled ability, (ii) developing self-made or customized facilities for the procedures of acidification and chemothermal oxidization, and (iii) optimizing procedures and carbon-sulfur analyzer, we have built a novel Wang-Xu-Yuan method (the WXY method) for measuring the contents of total organic carbon or black carbon in marine sediment cores, which includes the procedures of pretreatment, weighing, acidification, chemothermal oxidation and quantification; and can fully meet the requirements of establishing their highresolution temporal sequences, whatever in the recovery, experimental efficiency, accuracy and reliability of the measurements, and homogeneity of samples. In particular, the usage of disposable ceramic crucibles leads to evidently simplify the experimental scenario, which further results in the very high recovery rates for total organic carbon and black carbon. This new technique may provide a significant support for

  3. In vivo measurement of total body carbon using 238Pu/Be neutron sources

    International Nuclear Information System (INIS)

    Sutcliffe, J.F.; Mitra, S.; Hill, G.L.

    1990-01-01

    Total body carbon has been measured by in vivo neutron activation analysis (IVNAA) in 278 surgical gastroenterological patients and 29 normal volunteers. This is based on the inelastic scattering reaction { 12 C(n,n') 12 C*} for neutrons with energy above 4.8MeV, producing 4.43 MeV gamma rays. Since only part of the body is scanned, total body carbon is estimated as the ratio of the gamma ray emission from carbon to the emission from hydrogen, using hydrogen as the internal standard. The precision of the estimate is ±1.6kg for a whole body dose of 0.3mSv. There is a significant difference between the estimates of total body water from IVNAA measurements of carbon and nitrogen and measurements of body water in these subjects by tritium dilution (t=3.1, p < 0.005). (author)

  4. Coulometric precise analysis of total inorganic carbon in seawater and measurements of radiocarbon for the carbon dioxide in the atmosphere and for the total inorganic carbon in seawater

    International Nuclear Information System (INIS)

    Ishii, Masao; Inoue, Hisayuki Y.; Matsueda Hidekazu

    2000-01-01

    Climate change is one of the biggest issues on the earth, and the research on the climate system has been paid much attention today. The behavior of carbon dioxide (Co 2 ), one of the major green house gases, and its related substances within and among the atmosphere, the ocean and the land biosphere is playing a key role in regulating the climate. The ocean contains ca. 4x10 19 g of carbon, which is about 50 times of that in the atmosphere. The change in carbon cycle in the ocean is considered to have a crucial impact on the concentration of CO 2 in the atmosphere. However, little has been quantitatively known about the variability of CO 2 in the ocean and its controlling physical, chemical and biological processes. The observations of the concentration and carbon isotopic ratio of total dissolved inorganic carbon (TCO 2 ) in seawater occupy important part of the research on the behavior of carbon in the ocean. In the first part of this report, we describe the fundamental knowledge of CO 2 system in seawater and the method to precisely measure TCO 2 including sampling method, the structure and the operation of the instrument we developed, and the way to assure the quality of the data. We also present some results we obtained in the western North Pacific and the equatorial Pacific. In the second part, we report the methods to collect and treat samples for the analysis of the isotopic ratio of radio carbon ( 14 C) in the atmospheric CO 2 and TCO 2 in sea water. (author)

  5. Measurement of total-body oxygen, nitrogen, and carbon in vivo by photon activation analysis

    International Nuclear Information System (INIS)

    Ulin, K.

    1984-01-01

    With the aim of assessing nutritional status, the feasibility of measuring the total body quantities of the major body elements, i.e. oxygen, nitrogen, and carbon, using the photon beam of a 45 MV betatron and a whole-body counter, has been evaluated in detail. Following photon activation a single energy γ-radiation (.511 MeV) is observed from all three elements to be measured. The half-lives of 15 O, 13 N, and 11 C, however, are sufficiently different (20.5 min, 10.0 min, and 20.4 min. respectively) to permit their measurement from an analysis of the measured decay curve. Following corrections for interfering reactions, a computer curve-fitting algorithm is used to resolve the data into 15 O, 13 N, and 11 C components. Measurements of O, N, and C have been made both in phantoms and in live and dead rats. A comparison of the body composition results from this technique with results from chemical analysis indicates that measured carbon can quite accurately predict total body fat. The comparison of the total body nitrogen measurement by photon activation with total body protein by chemical analysis was inconclusive and suggests that further work be done to verify the estimated accuracy of the nitrogen measurement

  6. High-Accuracy Measurements of Total Column Water Vapor From the Orbiting Carbon Observatory-2

    Science.gov (United States)

    Nelson, Robert R.; Crisp, David; Ott, Lesley E.; O'Dell, Christopher W.

    2016-01-01

    Accurate knowledge of the distribution of water vapor in Earth's atmosphere is of critical importance to both weather and climate studies. Here we report on measurements of total column water vapor (TCWV) from hyperspectral observations of near-infrared reflected sunlight over land and ocean surfaces from the Orbiting Carbon Observatory-2 (OCO-2). These measurements are an ancillary product of the retrieval algorithm used to measure atmospheric carbon dioxide concentrations, with information coming from three highly resolved spectral bands. Comparisons to high-accuracy validation data, including ground-based GPS and microwave radiometer data, demonstrate that OCO-2 TCWV measurements have maximum root-mean-square deviations of 0.9-1.3mm. Our results indicate that OCO-2 is the first space-based sensor to accurately and precisely measure the two most important greenhouse gases, water vapor and carbon dioxide, at high spatial resolution [1.3 x 2.3 km(exp. 2)] and that OCO-2 TCWV measurements may be useful in improving numerical weather predictions and reanalysis products.

  7. Technical Note: Precise quantitative measurements of total dissolved inorganic carbon from small amounts of seawater using a gas chromatographic system

    Directory of Open Access Journals (Sweden)

    T. Hansen

    2013-10-01

    Full Text Available Total dissolved inorganic carbon (CT is one of the most frequently measured parameters used to calculate the partial pressure of carbon dioxide in seawater. Its determination has become increasingly important because of the rising interest in the biological effects of ocean acidification. Coulometric and infrared detection methods are currently favored in order to precisely quantify CT. These methods however are not sufficiently validated for CT measurements of biological experiments manipulating seawater carbonate chemistry with an extended CT measurement range (~1250–2400 μmol kg–1 compared to natural open ocean seawater (~1950–2200 μmol kg−1. The requirement of total sample amounts between 0.1–1 L seawater in the coulometric- and infrared detection methods potentially exclude their use for experiments working with much smaller volumes. Additionally, precise CT analytics become difficult with high amounts of biomass (e.g., phytoplankton cultures or even impossible in the presence of planktonic calcifiers without sample pre-filtration. Filtration however, can alter CT concentration through gas exchange induced by high pressure. Addressing these problems, we present precise quantification of CT using a small, basic and inexpensive gas chromatograph as a CT analyzer. Our technique is able to provide a repeatability of ±3.1 μmol kg−1, given by the pooled standard deviation over a CT range typically applied in acidification experiments. 200 μL of sample is required to perform the actual CT measurement. The total sample amount needed is 12 mL. Moreover, we show that sample filtration is applicable with only minor alteration of the CT. The method is simple, reliable and with low cumulative material costs. Hence, it is potentially attractive for all researchers experimentally manipulating the seawater carbonate system.

  8. German standard methods for the examination of water, waste water and sludge: General measurements of effects and substances (group H), determination of total organic carbon (TOC) (H 3)

    International Nuclear Information System (INIS)

    1982-01-01

    The following method for the determination of the total organic bound carbon is proposed. The carbon of the organic compounds is oxidized to carbon dioxide. There are three oxidation possibilities. Combustion, oxidation with proper oxidation agents in the solution and oxidation by irradiation of ultraviolette light. The resulting carbon dioxide or the possible reduction product methane are analysed with the following measuring instruments: Infrared spectroscopy, acidimetry, coulometry, conductometry, CO 2 sensitive electrodes, heat conductivity detection and flame ionisation detection. (VG) [de

  9. On-line technique for preparingand measuring stable carbon isotopeof total dissolved inorganic carbonin water samples ( d13CTDIC

    Directory of Open Access Journals (Sweden)

    S. Inguaggiato

    2005-06-01

    Full Text Available A fast and completely automated procedure is proposed for the preparation and determination of d13C of total inorganic carbon dissolved in water ( d13CTDIC. This method is based on the acidification of water samples transforming the whole dissolved inorganic carbon species into CO2. Water samples are directly injected by syringe into 5.9 ml vials with screw caps which have a pierciable rubber septum. An Analytical Precision «Carbonate Prep System» was used both to flush pure helium into the vials and to automatically dispense a fixed amount of H3PO4. Full-equilibrium conditions between produced CO2 and water are reached at a temperature of 70°C (± 0.1°C in less than 24 h. Carbon isotope ratios (13C/ 12C were measured on an AP 2003 continuous flow mass spectrometer, connected on-line with the injection system. The precision and reproducibility of the proposed method was tested both on aqueous standard solutions prepared using Na2CO3 with d13C=-10.78 per mil versus PDB (1 s= 0.08, n = 11, and at five different concentrations (2, 3, 4, 5 and 20 mmol/l and on more than thirty natural samples. Mean d13CTDIC on standard solution samples is ?10.89 < per mil versus PDB (1 s= 0.18, n = 50, thus revealing both a good analytical precision and reproducibility. A comparison between average d13CTDIC values on a quadruplicate set of natural samples and those obtained following the chemical and physical stripping method highlights a good agreement between the two analytical methods.

  10. Comparison between Random Forests, Artificial Neural Networks and Gradient Boosted Machines Methods of On-Line Vis-NIR Spectroscopy Measurements of Soil Total Nitrogen and Total Carbon

    Directory of Open Access Journals (Sweden)

    Said Nawar

    2017-10-01

    Full Text Available Accurate and detailed spatial soil information about within-field variability is essential for variable-rate applications of farm resources. Soil total nitrogen (TN and total carbon (TC are important fertility parameters that can be measured with on-line (mobile visible and near infrared (vis-NIR spectroscopy. This study compares the performance of local farm scale calibrations with those based on the spiking of selected local samples from both fields into an European dataset for TN and TC estimation using three modelling techniques, namely gradient boosted machines (GBM, artificial neural networks (ANNs and random forests (RF. The on-line measurements were carried out using a mobile, fiber type, vis-NIR spectrophotometer (305–2200 nm (AgroSpec from tec5, Germany, during which soil spectra were recorded in diffuse reflectance mode from two fields in the UK. After spectra pre-processing, the entire datasets were then divided into calibration (75% and prediction (25% sets, and calibration models for TN and TC were developed using GBM, ANN and RF with leave-one-out cross-validation. Results of cross-validation showed that the effect of spiking of local samples collected from a field into an European dataset when combined with RF has resulted in the highest coefficients of determination (R2 values of 0.97 and 0.98, the lowest root mean square error (RMSE of 0.01% and 0.10%, and the highest residual prediction deviations (RPD of 5.58 and 7.54, for TN and TC, respectively. Results for laboratory and on-line predictions generally followed the same trend as for cross-validation in one field, where the spiked European dataset-based RF calibration models outperformed the corresponding GBM and ANN models. In the second field ANN has replaced RF in being the best performing. However, the local field calibrations provided lower R2 and RPD in most cases. Therefore, from a cost-effective point of view, it is recommended to adopt the spiked European dataset

  11. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  12. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  13. Measurement of Neutrino and Antineutrino Total Charged-Current Cross Sections on Carbon with MINERvA

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Lu [Univ. of Pittsburgh, PA (United States)

    2017-01-01

    This thesis presents a measurement of charged-current inclusive cross sections of muon neutrino and antineutrino interaction on carbon, and antineutrino to neutrino cross section ratio, r, in the energy range 2 - 22 GeV, with data collected in the MINERA experiment. The dataset corresponds to an exposure of 3.2 x 1020 protons on target (POT) for neutrinos and 1.01020 POT for antineutrinos. Measurement of neutrino and antineutrino charged-current inclusive cross sections provides essential constraints for future long baseline neutrino oscillation experiment at a few GeV energy range. Our measured antineutrino cross section has an uncertainty in the range 6.1% - 10.5% and is the most precise measurement below 6 GeV to date. The measured r has an uncertainty of 5.0% - 7.5%. This is the rst measurement below 6 GeV since Gargamelle in 1970s. The cross sections are measured as a function of neutrino energy by dividing the eciency corrected charged-current sample with extracted uxes. Fluxes are obtained using the low- method, which uses low hadronic energy subsamples of charged-current inclusive sample to extract ux. Measured cross sections show good agreement with the prediction of neutrino interaction models above 7 GeV, and are about 10% below the model below 7 GeV. The measured r agrees with the GENIE model [1] over the whole energy region. The measured cross sections and r are compared with world data.

  14. Characterization of a catalyst-based conversion technique to measure total particulate nitrogen and organic carbon and comparison to a particle mass measurement instrument

    Science.gov (United States)

    Stockwell, Chelsea E.; Kupc, Agnieszka; Witkowski, Bartłomiej; Talukdar, Ranajit K.; Liu, Yong; Selimovic, Vanessa; Zarzana, Kyle J.; Sekimoto, Kanako; Warneke, Carsten; Washenfelder, Rebecca A.; Yokelson, Robert J.; Middlebrook, Ann M.; Roberts, James M.

    2018-05-01

    The chemical composition of aerosol particles is a key aspect in determining their impact on the environment. For example, nitrogen-containing particles impact atmospheric chemistry, air quality, and ecological N deposition. Instruments that measure total reactive nitrogen (Nr = all nitrogen compounds except for N2 and N2O) focus on gas-phase nitrogen and very few studies directly discuss the instrument capacity to measure the mass of Nr-containing particles. Here, we investigate the mass quantification of particle-bound nitrogen using a custom Nr system that involves total conversion to nitric oxide (NO) across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence detection. We evaluate the particle conversion of the Nr instrument by comparing to mass-derived concentrations of size-selected and counted ammonium sulfate ((NH4)2SO4), ammonium nitrate (NH4NO3), ammonium chloride (NH4Cl), sodium nitrate (NaNO3), and ammonium oxalate ((NH4)2C2O4) particles determined using instruments that measure particle number and size. These measurements demonstrate Nr-particle conversion across the Nr catalysts that is independent of particle size with 98 ± 10 % efficiency for 100-600 nm particle diameters. We also show efficient conversion of particle-phase organic carbon species to CO2 across the instrument's platinum catalyst followed by a nondispersive infrared (NDIR) CO2 detector. However, the application of this method to the atmosphere presents a challenge due to the small signal above background at high ambient levels of common gas-phase carbon compounds (e.g., CO2). We show the Nr system is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation using single-component, laboratory-generated, Nr-containing particles below 2.5 µm in size. In addition we show agreement with mass measurements of an independently calibrated online particle-into-liquid sampler directly coupled to the

  15. Measurement of total and differential cross sections of neutrino and antineutrino coherent π± production on carbon

    Science.gov (United States)

    Mislivec, A.; Higuera, A.; Aliaga, L.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Budd, H.; Caceres v., G. F. R.; Cai, T.; Martinez Caicedo, D. A.; Carneiro, M. F.; Chavarria, E.; da Motta, H.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Gran, R.; Harris, D. A.; Hurtado, K.; Jena, D.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; Messerly, B.; Miller, J.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Nguyen, C.; Norrick, A.; Nuruzzaman, Paolone, V.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Solano Salinas, C. J.; Sultana, M.; Sánchez Falero, S.; Tagg, N.; Valencia, E.; Wospakrik, M.; Yaeggy, B.; Zavala, G.; MinerνA Collaboration

    2018-02-01

    Neutrino induced coherent charged pion production on nuclei, ν¯ μA →μ±π∓A , is a rare inelastic interaction in which the four-momentum squared transferred to the nucleus is nearly zero, leaving it intact. We identify such events in the scintillator of MINERvA by reconstructing |t | from the final state pion and muon momenta and by removing events with evidence of energetic nuclear recoil or production of other final state particles. We measure the total neutrino and antineutrino cross sections as a function of neutrino energy between 2 and 20 GeV and measure flux integrated differential cross sections as a function of Q2 , Eπ, and θπ . The Q2 dependence and equality of the neutrino and antineutrino cross sections at finite Q2 provide a confirmation of Adler's partial conservation of axial current hypothesis.

  16. Predicting Soil Organic Carbon and Total Nitrogen in the Russian Chernozem from Depth and Wireless Color Sensor Measurements

    Science.gov (United States)

    Mikhailova, E. A.; Stiglitz, R. Y.; Post, C. J.; Schlautman, M. A.; Sharp, J. L.; Gerard, P. D.

    2017-12-01

    Color sensor technologies offer opportunities for affordable and rapid assessment of soil organic carbon (SOC) and total nitrogen (TN) in the field, but the applicability of these technologies may vary by soil type. The objective of this study was to use an inexpensive color sensor to develop SOC and TN prediction models for the Russian Chernozem (Haplic Chernozem) in the Kursk region of Russia. Twenty-one dried soil samples were analyzed using a Nix Pro™ color sensor that is controlled through a mobile application and Bluetooth to collect CIEL*a*b* (darkness to lightness, green to red, and blue to yellow) color data. Eleven samples were randomly selected to be used to construct prediction models and the remaining ten samples were set aside for cross validation. The root mean squared error (RMSE) was calculated to determine each model's prediction error. The data from the eleven soil samples were used to develop the natural log of SOC (lnSOC) and TN (lnTN) prediction models using depth, L*, a*, and b* for each sample as predictor variables in regression analyses. Resulting residual plots, root mean square errors (RMSE), mean squared prediction error (MSPE) and coefficients of determination ( R 2, adjusted R 2) were used to assess model fit for each of the SOC and total N prediction models. Final models were fit using all soil samples, which included depth and color variables, for lnSOC ( R 2 = 0.987, Adj. R 2 = 0.981, RMSE = 0.003, p-value < 0.001, MSPE = 0.182) and lnTN ( R 2 = 0.980 Adj. R 2 = 0.972, RMSE = 0.004, p-value < 0.001, MSPE = 0.001). Additionally, final models were fit for all soil samples, which included only color variables, for lnSOC ( R 2 = 0.959 Adj. R 2 = 0.949, RMSE = 0.007, p-value < 0.001, MSPE = 0.536) and lnTN ( R 2 = 0.912 Adj. R 2 = 0.890, RMSE = 0.015, p-value < 0.001, MSPE = 0.001). The results suggest that soil color may be used for rapid assessment of SOC and TN in these agriculturally important soils.

  17. Total cyanide mass measurement with micro-ion selective electrode for determination of specific activity of carbon-11 cyanide.

    Science.gov (United States)

    Shea, Colleen; Alexoff, David L; Kim, Dohyun; Hoque, Ruma; Schueller, Michael J; Fowler, Joanna S; Qu, Wenchao

    2015-08-01

    In this research, we aim to directly measure the specific activity (SA) of the carbon-11 cyanide ([(11)C]CN¯) produced by our in-house built automated [(11)C]HCN production system and to identify the major sources of (12)C-cyanide ((12)CN¯). The [(11)C]CN¯ is produced from [(11)C]CO2, which is generated by the (14)N(p,α)(11)C nuclear reaction using a cyclotron. Direct measurement of cyanide concentrations was accomplished using a relatively inexpensive, and easy to use ion selective electrode (ISE) which offered an appropriate range of sensitivity for detecting mass. Multiple components of the [(11)C]HCN production system were isolated in order to determine their relative contributions to (12)CN¯ mass. It was determined that the system gases were responsible for approximately 30% of the mass, and that the molecular sieve/nickel furnace unit contributed approximately 70% of the mass. Beam on target (33µA for 1 and 10min) did not contribute significantly to the mass. Additionally, we compared the SA of our [(11)C]HCN precursor determined using the ISE to the SA of our current [(11)C]CN¯ derived radiotracers determined by HPLC to assure there was no significant difference between the two methods. These results are the first reported use of an ion selective electrode to determine the SA of no-carrier-added cyanide ion, and clearly show that it is a valuable, inexpensive and readily available tool suitable for this purpose. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. An approach to the estimative the DBO and the DQO of residual waters by means of the measure of the total organic carbon

    International Nuclear Information System (INIS)

    Munoz, Horacio; Mejia, Gloria; Chaverra, Marlene; Vasquez, Esmeralda

    2000-01-01

    Using parameters like BOD and COD has normally done the measurement of the contents of biodegradable organic matter present in both water and wastewaters. Since the time required to obtain the first of them is too long for practical purposes plus the fact that precision achieved in analysis results is not too high for both, some troubles are encountered when evaluating pollution loads for different objectives (applying water quality criteria to discharge effluents or designing wastewater treatment facilities) this paper presents the results of a method of estimation of both parameters through the use of the total organic carbon contents of waste waters. Its detection is quick and accurate and could mean the access to a tool with many possibilities in water pollution assessment and waste water treatment control

  19. A new approach for the carbon monoxide (CO) exposure diagnosis: measurement of total CO in human blood versus carboxyhemoglobin (HbCO).

    Science.gov (United States)

    Varlet, Vincent; De Croutte, Emma Lagroy; Augsburger, Marc; Mangin, Patrice

    2013-07-01

    The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning. © 2013 American Academy of Forensic Sciences.

  20. Measuring the Total-Factor Carbon Emission Performance of Industrial Land Use in China Based on the Global Directional Distance Function and Non-Radial Luenberger Productivity Index

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-04-01

    Full Text Available Industry is a major contributor to carbon emissions in China, and industrial land is an important input to industrial production. Therefore, a detailed analysis of the carbon emission performance of industrial land use is necessary for making reasonable carbon reduction policies that promote the sustainable use of industrial land. This paper aims to analyze the dynamic changes in the total-factor carbon emission performance of industrial land use (TCPIL in China by applying a global directional distance function (DDF and non-radial Luenberger productivity index. The empirical results show that the eastern region enjoys better TCPIL than the central and western regions, but the regional gaps in TCPIL are narrowing. The growth in NLCPILs (non-radial Luenberger carbon emission performance of industrial land use in the eastern and central regions is mainly driven by technological progress, whereas efficiency improvements contribute more to the growth of NLCPIL in the western region. The provinces in the eastern region have the most innovative and environmentally-friendly production technologies. The results of the analysis of the influencing factors show implications for improving the NLCPIL, including more investment in industrial research and development (R&D, the implementation of carbon emission reduction policies, reduction in the use of fossil energy, especially coal, in the process of industrial production, actively learning about foreign advanced technology, properly solving the problem of surplus labor in industry and the expansion of industrial development.

  1. Quantifying Fire's Impacts on Total and Pyrogenic Carbon Stocks in Mixed-Conifer Forests: Results from Pre- and Post-Fire Measurements in Active Wildfire Incidents

    Science.gov (United States)

    Miesel, J. R.; Reiner, A. L.; Ewell, C. M.; Sanderman, J.; Maestrini, B.; Adkins, J.

    2016-12-01

    Widespread US fire suppression policy has contributed to an accumulation of vegetation in many western forests relative to historic conditions, and these changes can exacerbate wildfire severity and carbon (C) emissions. Serious concern exists about positive feedbacks between wildfire emissions and global climate; however, fires not only release C from terrestrial to atmospheric pools, they also create "black" or pyrogenic C (PyC) which contributes to longer-term C stability. Our objective was to quantify wildfire impacts on aboveground and belowground total C and PyC stocks in California mixed-conifer forests. We worked with incident management teams to access five active wildfires to establish and measure plots within days before and after fire. We measured pre- and post-fire aboveground forest structure and woody fuels to calculate aboveground biomass, biomass C, and PyC, and we collected pre- and post-fire forest floor and 0-5 cm mineral soil samples to measure belowground C and PyC stocks. Our preliminary results show that fire had minimal impact on the number of trees per hectare, whereas C losses from the tree layer occurred via consumption of foliage, and PyC gain occurred in tree bark. Fire released 54% to 100% of surface fuel C. In the forest floor layer, we observed 33 to 100% C loss, whereas changes in PyC stocks ranged from 100% loss to 186% gain relative to pre-fire samples. In general, fire had minimal to no impact on 0-5 cm mineral soil C. We will present relationships between total C, PyC and post-fire C and N dynamics in one of the five wildfire sites. Our data are unique because they represent nearly immediate pre- and post-fire measurements in major wildfires in a widespread western U.S. forest type. This research advances understanding of the role of fire on forest C fluxes and C sequestration potential as PyC.

  2. Tracing carbon fixation in phytoplankton—compound specific and total

    NARCIS (Netherlands)

    Grosse, J.; Van Breugel, P.; Boschker, H.T.S.

    2015-01-01

    Measurement of total primary production using 13C incorporation is a widely established tool. However, these bulk measurements lack information about the fate of fixed carbon: the production of major cellular compounds (carbohydrates, amino acids, fatty acids, and DNA/RNA) is affected by for

  3. CH4, CO, and H2O spectroscopy for the Sentinel-5 Precursor mission: an assessment with the Total Carbon Column Observing Network measurements

    NARCIS (Netherlands)

    Galli, A.; Butz, A.; Scheepmaker, R.A.; Hasekamp, O.; Landgraf, J.; Tol, P.J.J.; Wunch, D.; Deutscher, N.M.; Toon, G.C.; Wennberg, P.O.; Griffith, D.W.T.; Aben, E.A.A.

    2012-01-01

    The TROPOspheric Monitoring Instrument (TROPOMI) will be part of ESA's Sentinel-5 Precursor (S5P) satellite platform scheduled for launch in 2015. TROPOMI will monitor methane and carbon monoxide concentrations in the Earth's atmosphere by measuring spectra of back-scattered sunlight in the

  4. Long term carbon dioxide exchange above a mixed forest in the Belgian Ardennes: evaluation of different approaches to deduce total ecosystem respiration from Eddy covariance measurements

    Science.gov (United States)

    Jérôme, Elisabeth; Aubinet, Marc; Heinesch, Bernard

    2010-05-01

    The general aim of this research is to analyze inter annual variability of carbon dioxide (CO2) fluxes exchanged by a mixed forest located at the Vielsalm experimental site in Belgium. At this site, CO2 flux measurements started in 1996 and are still going on. Thirteen complete years of measurements are thus available. Net Ecosystem Exchange (NEE) inter annual variability may be driven by gross primary productivity (GPP) or Total Ecosystem Respiration (TER), which should thus be both quantified. Using flux partitioning methods, TER is deduced from NEE measurements. GPP is then obtained by subtracting TER from NEE. Initially, a robust estimation of TER is required. This work seeks to compare two independent approaches to assess TER in order to quantify the implications on inter-annual variability. The comparison was performed on twelve complete years. TER estimates can be deduced by extrapolating to the whole day NEE measurements taken during selected night or day periods. In both case, the extrapolation is performed by using a respiration response to temperature. The first approach, referred as the night-time approach, consisted in calculating TER using a temperature response function derived from night-time data sets (Reichstein et al., 2005). The second approach, referred as the daytime approach, consisted in assessing TER from the intercept of the NEE/Photosynthetically Photon Flux Density (PPFD) response (Wohlfahrt et al., 2005). For each approach, different modalities were compared: the use of long term (annual) or short term (15 days) data sets for the night-time approach and the use of different types of regression for the daytime approach. In addition, the impact of the temperature choice was studied for each of the approaches. For the night-time approach, main results showed that air temperature sensitivity of ecosystem respiration derived from annual data did not reflect the short-term air temperature sensitivity. Vielsalm is a summer active ecosystem

  5. Total cross-section measurements on aluminium, carbon, fluorine and hydrogen for d, d reaction neutrons using the coincidence method (1963); Mesure de la section efficace totale de l'aluminium, du carbone, du fluor et de l'hydrogene pour des neutrons de la reaction d, d par la methode des coincidences (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, G; Sorriaux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The experiment described consists in the measurement of the total cross-section of various materials: aluminium, carbon, fluorine and hydrogen, for mono-energetic 2.77 MeV neutrons obtained from the d,d reaction. The measurement is carried out by transmission. The neutrons are detected by means of a plastic scintillator mounted on a 56 AVP photomultiplier, and are isolated from all secondary phenomena (background noise, scattered neutrons) by coincidence with helium 3. which particles are associated to the neutrons from the reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H The helium 3 particles are detected by a PN junction diode used with inverted polarisation. An absorption exponential has been traced out using measurements made on seven aluminium bars. The accuracy of the total cross-section measurements is about 10{sup -2}. (authors) [French] L'experience exposee dans ce rapport consiste en la mesure des sections efficaces totales de differents materiaux: aluminium, carbone, fluor et hydrogene, pour des neutrons monoenergetiques de 2,77 MeV, obtenus par la reaction d,d. La mesure est faite par transmission. Les neutrons sont detectes par un scintillateur plastique monte sur un photomultiplicateur 56 AVP, et sont separes de tout phenomene secondaire (bruit de fond, neutrons diffuses) par coincidence avec les helium 3, particules associees aux neutrons de la reaction {sup 2}{sub 1}D ({sup 2}{sub 1}D, n) {sup 3}{sub 2}H Les helium 3 sont detectes par une diode a jonction PN utilisee en polarisation inverse. Une exponentielle d'absorption a ete tracee a partir de mesures faites sur sept barreaux d'aluminium. La precision des mesures des sections efficaces totales est de l'ordre de 10{sup -2}. (auteurs)

  6. Defense meteorological satellite measurements of total ozone

    International Nuclear Information System (INIS)

    Lovill, J.E.; Ellis, J.S.; Luther, F.M.; Sullivan, R.J.; Weichel, R.L.

    1992-01-01

    A multichannel filter radiometer (MFR) on Defense Meteorological Satellites (DMS) that measured total ozone on a global-scale from March 1977 - February 1980 is described. The total ozone data measured by the MFR were compared with total ozone data taken by surfaced-based Dobson spectrophotometers. When comparisons were made for five months, the Dobson spectrophotometer measured 2-5% more total ozone than the MFR. Comparisons between the Dobson spectrophotometer and the MFR showed a reduced RMS difference as the comparisons were made at closer proximity. A Northern Hemisphere total ozone distribution obtained from MFR data is presented

  7. Comparison of total haemoglobin mass measured with the optimized carbon monoxide rebreathing method across different Radiometer™ ABL-80 and OSM-3 hemoximeters

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M

    2014-01-01

    A new Radiometer™ hemoximeter (ABL-80) has recently become available to measure carboxyhaemoglobin concentration for the optimized CO-rebreathing method (oCOR-method). Within the English Institute of Sport (EIS), hemoximeters are used in three different laboratories; therefore, precision and agreement of total haemoglobin mass (tHbmass) determination across sites is essential, and comparison to the previous model OSM-3 is desirable. Six male and one female (age 30  ±  6 years, body mass 78.1  ±  10.6 kg) undertook the oCOR-method. Venous blood (∼2 ml) was sampled immediately before and at 7 min during the oCOR-method; with seven replicates from each time point simultaneously analysed on five different Radiometer™ hemoximeters [OSM-3(1), OSM-3(2), ABL-80(1), ABL-80(2) and ABL-80(3)]. There were no differences (p > 0.05) between Δ%HbCO or mean tHbmass analysed with five different hemoximeters (OSM-3(1): 886  ±  167 g; OSM-3(2): 896  ±  160 g: ABL-80(1): 904  ±  157 g; ABL-80(2): 906  ±  163 g: ABL-80(3): 906  ±  162 g). However, the Bland–Altman plot revealed that there was closer agreement between ABL-80 machines for tHbmass than for the OSM-3. The variance (i.e. % error) across replicate samples decreased as the number of samples increased, with the error derived from the ‘worse-case’ scenario (single samples) being 1.2 to 1.6 fold greater in the OSM-3 than the ABL-80. Although there were no differences in the average tHbmass measured with five different hemoximeters, the new ABL-80 were in better agreement with each other compared to the old OSM-3. Previously, five replicates were required to achieve a low error using the OSM-3; however, three replicates are sufficient with the ABL-80 model to produce an error of ≤ 1% in tHbmass. (note)

  8. Total Belowground Carbon Allocation in a Fast-growing Eucalyptus Plantation Estimated Using a Carbon Balance Approach

    Science.gov (United States)

    Christian P. Giardina; Michael G. Ryan

    2002-01-01

    Trees allocate a large portion of gross primary production belowground for the production and maintenance of roots and mycorrhizae. The difficulty of directly measuring total belowground carbon allocation (TBCA) has limited our understanding of belowground carbon (C) cycling and the factors that control this important flux. We measured TBCA over 4 years using a...

  9. Supercritical Water Oxidation Total Organic Carbon (TOC) Analysis

    Science.gov (United States)

    The work presented here is the evaluation of the modified wet‐oxidation method described as Supercritical Water Oxidation (SCWO) for the analysis of total organic carbon (TOC) in very difficult oil/gas produced water sample matrices.

  10. Mini Total Organic Carbon Analyzer (miniTOCA)

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this development is to create a prototype hand-held, 1 to 2 liter size battery-powered Total Organic Carbon Analyzer (TOCA). The majority of...

  11. LAMBDA p total cross-section measurement

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    A view of the apparatus used for the LAMBDA p total cross-section measurement at the time of its installation. The hyperons decaying into a proton and a pion in the conical tank in front were detected in the magnet spectrometer in the upper half of the picture. A novel detection technique using exclusively multiwire proportional chambers was employed.

  12. The effect of sodium bicarbonate and validation of beckman coulter AU680 analyzers for measuring total carbon dioxide (TCO2) concentrations in horse serum.

    Science.gov (United States)

    Dirikolu, Levent; Waller, Pamela; Waguespack, Mona Landry; Andrews, Frank Michael; Keowen, Michael Layne; Gaunt, Stephen David

    2017-11-01

    This study evaluated the usage of Beckman Coulter AU680 analyzers for measurement of TCO 2 in horse serum, and the effect of sodium bicarbonate administrations on serum TCO 2 levels in resting horses. Treatment of horses with sodium bicarbonate did not result in any adverse events. Mean TCO 2 concentration was significantly higher from 1 to 8 h in the sodium bicarbonate-treated horses compared to the untreated controls. Within an hour, administration of sodium bicarbonate increased the TCO 2 level from 31.5 ± -2.5 (SD) to 34.0 ± 2.65 (SD) mmol/L and at 2-8 h post-administration, the TCO 2 level was above the 36 mmol/L cut-off level. In all quality control analysis of Australian standard by Beckman Coulter AU680 analyzer, the instrument slightly over estimated the TCO 2 level but the values were in close agreement with mean TCO 2 level being 38.03 with ± 0.87 mmol/L (SD). Expanded uncertainty was calculated using different levels of confidence interval. Based on 99.5% confidence interval using 0.805% expanded uncertainty using mean measured concentration of 38.05 mmol/L, it was estimated that any race samples TCO 2 level higher than 38.5 mmol/L will be indicative of sodium bicarbonate administration using Beckman Coulter AU680 analyzer in Louisiana.

  13. Emissions & Measurements - Black Carbon

    Science.gov (United States)

    Emissions and Measurement (EM) research activities performed within the National Risk Management Research Lab NRMRL) of EPA's Office of Research and Development (ORD) support measurement and laboratory analysis approaches to accurately characterize source emissions, and near sour...

  14. Evaluating Carbonate System Algorithms in a Nearshore System: Does Total Alkalinity Matter?

    Science.gov (United States)

    Jones, Jonathan M; Sweet, Julia; Brzezinski, Mark A; McNair, Heather M; Passow, Uta

    2016-01-01

    Ocean acidification is a threat to many marine organisms, especially those that use calcium carbonate to form their shells and skeletons. The ability to accurately measure the carbonate system is the first step in characterizing the drivers behind this threat. Due to logistical realities, regular carbonate system sampling is not possible in many nearshore ocean habitats, particularly in remote, difficult-to-access locations. The ability to autonomously measure the carbonate system in situ relieves many of the logistical challenges; however, it is not always possible to measure the two required carbonate parameters autonomously. Observed relationships between sea surface salinity and total alkalinity can frequently provide a second carbonate parameter thus allowing for the calculation of the entire carbonate system. Here, we assessed the rigor of estimating total alkalinity from salinity at a depth sampling water from a pier in southern California for several carbonate system parameters. Carbonate system parameters based on measured values were compared with those based on estimated TA values. Total alkalinity was not predictable from salinity or from a combination of salinity and temperature at this site. However, dissolved inorganic carbon and the calcium carbonate saturation state of these nearshore surface waters could both be estimated within on average 5% of measured values using measured pH and salinity-derived or regionally averaged total alkalinity. Thus we find that the autonomous measurement of pH and salinity can be used to monitor trends in coastal changes in DIC and saturation state and be a useful method for high-frequency, long-term monitoring of ocean acidification.

  15. DEVELOP NEW TOTAL ORGANIC CARBON/SPECIFIC UV ...

    Science.gov (United States)

    The purpose of this project is to provide a total organic carbon (TOC)/specific ultraviolet absorbance (SUVA) method that will be used by the Office of Ground Water and Drinking Water (OGWDW) to support monitoring requirements of the Stage 2 Disinfectant/Disinfection By-products (D/DBP) Rule. The Stage 2 Rule requires that enhanced water treatment be used if the source water is high in aquatic organic matter prior to the application of a disinfectant. Disinfectants (chlorine, ozone, etc.) are used in the production of drinking water in order to reduce the risk of microbial disease. These disinfectants react with the organic material that is naturally present in the source water to form disinfection by-products (DBPs). Exposure to some of these by-products may pose a long term health risk. The number and nature of DBPs make it impossible to fully characterize all of the by-products formed during the treatment of drinking water and it is more cost effective to reduce formation of DBPs than to remove them from the water after they are formed. Two measurements (TOC and SUVA) are believed to be predictive of the amount of by-products that can be formed during the disinfection of drinking water and are considered to be surrogates for DBP precursors. SUVA is calculated as the ultraviolet absorption at 254nm (UV254) in cm-1 divided by the mg/L dissolved organic carbon (DOC) concentration (measured after filtration of the water through a 0.45um pore-diameter filte

  16. Diffuse Reflectance Spectroscopy for Total Carbon Analysis of Hawaiian Soils

    Science.gov (United States)

    McDowell, M. L.; Bruland, G. L.; Deenik, J. L.; Grunwald, S.; Uchida, R.

    2010-12-01

    Accurate assessment of total carbon (Ct) content is important for fertility and nutrient management of soils, as well as for carbon sequestration studies. The non-destructive analysis of soils by diffuse reflectance spectroscopy (DRS) is a potential supplement or alternative to the traditional time-consuming and costly combustion method of Ct analysis, especially in spatial or temporal studies where sample numbers are large. We investigate the use of the visible to near-infrared (VNIR) and mid-infrared (MIR) spectra of soils coupled with chemometric analysis to determine their Ct content. Our specific focus is on Hawaiian soils of agricultural importance. Though this technique has been introduced to the soil community, it has yet to be fully tested and used in practical applications for all soil types, and this is especially true for Hawaii. In short, DRS characterizes and differentiates materials based on the variation of the light reflected by a material at certain wavelengths. This spectrum is dependent on the material’s composition, structure, and physical state. Multivariate chemometric analysis unravels the information in a set of spectra that can help predict a property such as Ct. This study benefits from the remarkably diverse soils of Hawaii. Our sample set includes 216 soil samples from 145 pedons from the main Hawaiian Islands archived at the National Soil Survey Center in Lincoln, NE, along with more than 50 newly-collected samples from Kauai, Oahu, Molokai, and Maui. In total, over 90 series from 10 of the 12 soil orders are represented. The Ct values of these samples range from < 1% - 55%. We anticipate that the diverse nature of our sample set will ensure a model with applicability to a wide variety of soils, both in Hawaii and globally. We have measured the VNIR and MIR spectra of these samples and obtained their Ct values by dry combustion. Our initial analyses are conducted using only samples obtained from the Lincoln archive. In this

  17. Total performance measurement and management: TPM2

    Energy Technology Data Exchange (ETDEWEB)

    Sheather, G. [University of Technology, Sydney, NSW (Australia)

    1996-10-01

    As the rate of incremental improvement activities and business process re-engineering programs increase, product development times reduce, collaborative endeavours between OEMs and out-sourcing suppliers increase, as agile manufacturing responds to the demands of a global marketplace, the `virtual` organisation is becoming a reality. In this context, customers, partners, suppliers and manufacturers are increasingly separated by field geography, time zone, and availability, but linked by distributed information systems. Measuring and monitoring business performance in this environment requires a entirely different framework and set of key performance indicators (KPIs) usually associated with traditional financial accounting approaches. These approaches are critiqued, then the paper introduces a new concept `Total Performance Measurement Management` (TPM2), to distinguish it from the conventional TPM (Total Productive Management). A model for combining both financial and non-financial KPIs relevant to real-time performance measures stretching across strategic, business unit and operational levels, is presented. The results of the model confirm the hypothesis that it is feasible to develop a TPM2 framework for achieving enterprise wide strategic objectives. (author). 6 tabs., 18 figs., refs.

  18. The research of a method for determination of total carbon, combination carbon and free carbon in beryllium metal

    International Nuclear Information System (INIS)

    Yang Xingzhong; Zhu Xiaohong

    1996-02-01

    A method for determination of total carbon, combination carbon and free carbon in beryllium metal with LECO CS-344 carbon/sulphur determinant has been studied. Tungsten-copper mixed pellets are used as flux to the determination of total carbon. Ratio of weight of the flux to the sample is greater than 20:1. Good analytical results are got. By this method the relative standard deviation is <10% when the content of total carbon in the range of 0.050%∼0.080% in beryllium. A standard steel sample of carbon is added into beryllium, the recoveries are 94%∼106%. For determination of free carbon, the sample are decomposed with 3 mol/L HCl, filtered and followed determination. By this method the relative standard deviation is ≤10% when the content of free carbon in the range of 0.006%∼0.020% in beryllium. the balance of total carbon and free carbon is equal to combination carbon. The method is used to determine the sample of content of total carbon in the range of 0.050%∼1.00%, free carbon in the range of 0.006%∼0.500% in metal beryllium. (6 refs., 1 fig., 13 tabs.)

  19. measurements with a total absorption detector

    International Nuclear Information System (INIS)

    Shibata, Michihiro; Kawade, Kiyoshi; Shindou, Terumasa; Kojima, Yasuaki; Taniguchi, Akihiro; Kawase, Yoichi; Ichikawa, Shin-ichi

    2003-01-01

    For Q β determination, we have developed a newly total absorption detector that can detect almost all radiation from the radioactive nuclei. The detector is composed of large volume and low background twin BGO scintillation detectors. The estimated efficiency is more than two orders of magnitude larger than those of Ge or Si detectors. The Q β s of some fission products of 235 U were successfully measured using an on-line mass separator for the first time (KUR-ISOL). We have proposed the possibility of determination Q β up to about 10 MeV using the detector without the knowledge of the decay scheme. (author)

  20. Determination of total carbonates in soil archaeometry using a new pressure method with temperature compensation

    Science.gov (United States)

    Barouchas, Pantelis; Koulos, Vasilios; Melfos, Vasilios

    2017-04-01

    For the determination of total carbonates in soil archaeometry a new technique was applied using a multi-sensor philosophy, which combines simultaneous measurement of pressure and temperature. This technology is innovative and complies with EN ISO 10693:2013, ASTM D4373-02(2007) and Soil Science Society of America standard test methods for calcium carbonate content in soils and sediments. The total carbonates analysis is based on a pressure method that utilizes the FOGII Digital Soil CalcimeterTM, which is a portable apparatus. The total carbonate content determined by treating a 1.000 g (+/- 0.001 g) dried sample specimens with 6N hydrochloric acid (HCL) reagent grade, in an enclosed reaction vessel. Carbon dioxide gas evolved during the reaction between the acid and carbonate fraction of the specimen, was measured by the resulting pressure generated, taking in account the temperature conditions during the reaction. Prior to analysis the procedure was validated with Sand/Soil mixtures from BIPEA proficiency testing program with soils of different origins. For applying this new method in archaeometry a total number of ten samples were used from various rocks which are related with cultural constructions and implements in Greece. They represent a large range of periods since the Neolithic times, and were selected because there was an uncertainty about their accurate mineralogical composition especially regarding the presence of carbonate minerals. The results were compared to the results from ELTRA CS580 inorganic carbon analyzer using an infrared cell. The determination of total carbonates for 10 samples from different ancient sites indicated a very good correlation (R2 >0.97) between the pressure method with temperature compensation and the infrared method. The proposed method is quickly and accurate in archaeometry and can replace easily other techniques for total carbonates testing. The FOGII Digital Soil CalcimeterTM is portable and easily can be carried for

  1. Measurement of carbon capture efficiency and stored carbon leakage

    Science.gov (United States)

    Keeling, Ralph F.; Dubey, Manvendra K.

    2013-01-29

    Data representative of a measured carbon dioxide (CO.sub.2) concentration and of a measured oxygen (O.sub.2) concentration at a measurement location can be used to determine whether the measured carbon dioxide concentration at the measurement location is elevated relative to a baseline carbon dioxide concentration due to escape of carbon dioxide from a source associated with a carbon capture and storage process. Optionally, the data can be used to quantify a carbon dioxide concentration increase at the first location that is attributable to escape of carbon dioxide from the source and to calculate a rate of escape of carbon dioxide from the source by executing a model of gas-phase transport using at least the first carbon dioxide concentration increase. Related systems, methods, and articles of manufacture are also described.

  2. Emissions & Measurements - Black Carbon | Science ...

    Science.gov (United States)

    Emissions and Measurement (EM) research activities performed within the National Risk Management Research Lab NRMRL) of EPA's Office of Research and Development (ORD) support measurement and laboratory analysis approaches to accurately characterize source emissions, and near source concentrations of air pollutants. They also support integrated Agency research programs (e.g., source to health outcomes) and the development of databases and inventories that assist Federal, state, and local air quality managers and industry implement and comply with air pollution standards. EM research underway in NRMRL supports the Agency's efforts to accurately characterize, analyze, measure and manage sources of air pollution. This pamphlet focuses on the EM research that NRMRL researchers conduct related to black carbon (BC). Black Carbon is a pollutant of concern to EPA due to its potential impact on human health and climate change. There are extensive uncertainties in emissions of BC from stationary and mobile sources. Emissions and Measurement (EM) research activities performed within the National Risk Management Research Lab NRMRL) of EPA's Office of Research and Development (ORD)

  3. Vertical distribution of total carbon, nitrogen and phosphorus in sediments of Drug Spring Lake, Wudalianchi

    Science.gov (United States)

    Zeng, Ying; Yang, Chen

    2018-02-01

    The content of total organic carbon, total nitrogen and total phosphorus in sediments of Drug Spring Lake was detected and their vertical distribution characteristic was analysed. Results showed that there were significant changes to the content of total organic carbon, total nitrogen and total phosphorus in different depth of the columnar sediments. Their highest content both appeared in the interval of 10cm to 25cm corresponding to the period of 1980s to 1990s, when the tourism of Wudalianchi scenic area began to develop. It reflected the impact of human activities on the Drug Spring Lake. That means the regulation was still not enough, although a series of pollution control measures adopted by the government in recent years had initial success.

  4. Apparatus for measuring total flow in pipes

    International Nuclear Information System (INIS)

    Matthews, H.

    1986-01-01

    To obtain a sample representative of the total flow in a pipe over a given period a Pitot tube is located in the pipe and connected to a collector outside the pipe. The collector is pressurised to a pressure substantially equal to the static head of the flow in the pipe via a line. Liquid is discharged from a collector to a container which is vented to atmosphere. (author)

  5. Measurement of total body radioactivity in man

    International Nuclear Information System (INIS)

    Naversten, Y.

    1982-01-01

    Techniques for the determination of whole-body radioactivity in man using uncollimated NaI(Tl) detectors have been studied. Geometrical effects and photon attenuation effects due to the different shapes of humans as well as due to varying in-vivo radioactivity distributions have been evaluated particularly for scanning-bed geometries and the chair geometry. Theoretically it is shown that the attenuation effects are generally dominating, for full-energy-peak pulse-range methods. For the application in radiation protection a cheap and simple chair-geometry unit has been constructed and used at various places distantly from the home-laboratory, for studies of body activity of Cs-137 in northern Sweden. High body activities were found particularly in reindeer-breeding Lapps. The elimination rate of Cs-137 in man was studied in the stationary whole-body counter in Lund as well as with the field-system. For the study of the performances at low and high photon energies clinical applications of methods for gastro-intestinal absorption of vitamin B12 (Co-57; 122 keV) and total body potassium determination (K-40; 1.46 MeV, K-42; 1.52 MeV) have been evaluated. Theoretical and experimental results as well as experiences of applications in radiation protection and medicine show that the scanning-bed geometry effectively evens out redistributional effects. For optimum results, however, scatter-energy pulse-ranges rather than full-energy-peak ranges should be used. (Auth.)

  6. Maximum total organic carbon limit for DWPF melter feed

    International Nuclear Information System (INIS)

    Choi, A.S.

    1995-01-01

    DWPF recently decided to control the potential flammability of melter off-gas by limiting the total carbon content in the melter feed and maintaining adequate conditions for combustion in the melter plenum. With this new strategy, all the LFL analyzers and associated interlocks and alarms were removed from both the primary and backup melter off-gas systems. Subsequently, D. Iverson of DWPF- T ampersand E requested that SRTC determine the maximum allowable total organic carbon (TOC) content in the melter feed which can be implemented as part of the Process Requirements for melter feed preparation (PR-S04). The maximum TOC limit thus determined in this study was about 24,000 ppm on an aqueous slurry basis. At the TOC levels below this, the peak concentration of combustible components in the quenched off-gas will not exceed 60 percent of the LFL during off-gas surges of magnitudes up to three times nominal, provided that the melter plenum temperature and the air purge rate to the BUFC are monitored and controlled above 650 degrees C and 220 lb/hr, respectively. Appropriate interlocks should discontinue the feeding when one or both of these conditions are not met. Both the magnitude and duration of an off-gas surge have a major impact on the maximum TOC limit, since they directly affect the melter plenum temperature and combustion. Although the data obtained during recent DWPF melter startup tests showed that the peak magnitude of a surge can be greater than three times nominal, the observed duration was considerably shorter, on the order of several seconds. The long surge duration assumed in this study has a greater impact on the plenum temperature than the peak magnitude, thus making the maximum TOC estimate conservative. Two models were used to make the necessary calculations to determine the TOC limit

  7. METHOD 415.3 - MEASUREMENT OF TOTAL ORGANIC ...

    Science.gov (United States)

    2.0 SUMMARY OF METHOD2.1 In both TOC and DOC determinations, organic carbon in the water sample is oxidized to form carbon dioxide (CO2), which is then measured by a detection system. There are two different approaches for the oxidation of organic carbon in water samples to carbon dioxide gas: (a) combustion in an oxidizing gas and (b) UV promoted or heat catalized chemical oxidation with a persulfate solution. Carbon dioxide, which is released from the oxidized sample, is detected by a conductivity detector or by a nondispersive infrared (NDIR) detector. Instruments using any combination of the above technologies may be used in this method.2.2. Setteable solids and floating matter may cause plugging of valves, tubing, and the injection needle port. The TOC procedure allows the removal of settleable solids and floating matter. The suspended matter is considered part of the sample. The resulting water sample is then considered a close approximation of the original whole water sample for the purpose of TOC measurement.2.3. The DOC procedure requires that the sample be passed through a 0.45 um filter prior to analysis.2.4. The TOC and DOC procedures require that all inorganic carbon be removed from the sample before the sample is analyzed for organic carbon content. If the inorganic carbon (IC) is not completely removed, significant error will occur. The inorganic carbon interference is removed by converting the mineralized IC to CO2 by acidification and

  8. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  9. Measuring carbon in shrubs. Chapter 5

    Science.gov (United States)

    David C. Chojnacky; Mikaila Milton

    2008-01-01

    Although shrubs are a small component of the overall carbon budget, shrub lands and shrub cover within forested lands warrant monitoring with consistent procedures to account for carbon in shrubs and to track carbon accumulation as communities change from shrubs to trees and vice versa. Many different procedures have been used to sample and measure shrubs (Bonham 1989...

  10. Carbonate chemistry, water quality, coral measurements

    Data.gov (United States)

    U.S. Environmental Protection Agency — Carbonate chemistry parameters (pH, total alkalinity, and pCO2), water quality parameters (Temperature, salinity, Ca, Mg, PO4, NH3 and NO3) as well as all coral...

  11. [Measurement model of carbon emission from forest fire: a review].

    Science.gov (United States)

    Hu, Hai-Qing; Wei, Shu-Jing; Jin, Sen; Sun, Long

    2012-05-01

    Forest fire is the main disturbance factor for forest ecosystem, and an important pathway of the decrease of vegetation- and soil carbon storage. Large amount of carbonaceous gases in forest fire can release into atmosphere, giving remarkable impacts on the atmospheric carbon balance and global climate change. To scientifically and effectively measure the carbonaceous gases emission from forest fire is of importance in understanding the significance of forest fire in the carbon balance and climate change. This paper reviewed the research progress in the measurement model of carbon emission from forest fire, which covered three critical issues, i. e., measurement methods of forest fire-induced total carbon emission and carbonaceous gases emission, affecting factors and measurement parameters of measurement model, and cause analysis of the uncertainty in the measurement of the carbon emissions. Three path selections to improve the quantitative measurement of the carbon emissions were proposed, i. e., using high resolution remote sensing data and improving algorithm and estimation accuracy of burned area in combining with effective fuel measurement model to improve the accuracy of the estimated fuel load, using high resolution remote sensing images combined with indoor controlled environment experiments, field measurements, and field ground surveys to determine the combustion efficiency, and combining indoor controlled environment experiments with field air sampling to determine the emission factors and emission ratio.

  12. Total porosity of carbonate reservoir rocks by X-ray microtomography in two different spatial resolutions

    International Nuclear Information System (INIS)

    Nagata, Rodrigo; Appoloni, Carlos R.; Marques, Leonardo C.; Fernandes, Celso P.

    2011-01-01

    Carbonate reservoir rocks contain more than 50% of world's petroleum. To know carbonate rocks' structural properties is quite important to petroleum extraction. One of their main structural properties is the total porosity, which shows the rock's capacity to stock petroleum. In recent years, the X-ray microtomography had been used to analyze the structural parameters of reservoir rocks. Such nondestructive technique generates images of the samples' internal structure, allowing the evaluation of its properties. The spatial resolution is a measurement parameter that indicates the smallest structure size observable in a sample. It is possible to measure one sample using two or more different spatial resolutions in order to evaluate the samples' pore scale. In this work, two samples of the same sort of carbonate rock were measured, and in each measurement a different spatial resolution (17 μm and 7 μm) was applied. The obtained results showed that with the better resolution it was possible to measure 8% more pores than with the poorer resolution. Such difference provides us with good expectations about such approach to study the pore scale of carbonate rocks. (author)

  13. Evaluation of robustness in the validation of total organic carbon (TOC) methodology

    International Nuclear Information System (INIS)

    Benedetti, Stella; Monteiro, Elisiane G.; Almeida, Erika V.; Oliveira, Ideli M.; Cerqueira Filho, Ademar C.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.

    2009-01-01

    Water is used in many steps of production and quality control as raw material for reagent preparation or dilution of solutions and for cleaning apparatus and room areas in the pharmaceutical industry, including radiopharmaceutical plants. Regulatory requirements establish specifications of purified water for different purposes. The quality of water is essential to guarantee the safe utilization of radiopharmaceuticals. A variety of methods and systems can be used to produce purified water and water for injection and all of them must fulfill the requirements for their specific use, which include TOC (total organic carbon) analysis, an indirect measurement of organic molecules present in water. The principle of TOC method is the oxidation of organic molecules to carbon dioxide, related to the carbon concentration. The aim of this study was to evaluate the parameters of robustness in TOC method in water used in the production and quality control procedures in the Radiopharmacy Directory (DIRF), according to Resolution 899 from ANVISA (National Sanitary Agency). Purified water were obtained from Milli-RX45 system. TOC standard solutions in the range of 100-1000 ppb were prepared with potassium hydrogen phthalate anhydride, transferred to vials and sequentially analyzed by a catalytic photo-oxidation reaction with a TOC model Vwp equipment from Shimadzu Corporation (Japan). The evaluated parameters were: oxidizing volume from 0.5 to 2.5 mL, acidifying volume from 1 to 5%, integration time for TC (total carbon) and IC (inorganic carbon) curves from 2 to 10 minutes. (author)

  14. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ovari, M.; Streli, C.; Wobrauschek, P.; Zaray, Gy.

    2009-01-01

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  15. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovari, M. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)], E-mail: ovari@chem.elte.hu; Streli, C.; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, Stadionallee 2, A-1020, Wien (Austria); Zaray, Gy. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary); Cooperative Research Centre of Environmental Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)

    2009-08-15

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  16. Total organic carbon in aggregates as a soil recovery indicator

    Science.gov (United States)

    Luciene Maltoni, Katia; Rodrigues Cassiolato, Ana Maria; Amorim Faria, Glaucia; Dubbin, William

    2015-04-01

    The soil aggregation promotes physical protection of organic matter, preservation of which is crucial to improve soil structure, fertility and ensure the agro-ecosystems sustainability. The no-tillage cultivation system has been considered as one of the strategies to increase total soil organic carbono (TOC) contents and soil aggregation, both are closely related and influenced by soil management systems. The aim of this study was to evaluate the distribution of soil aggregates and the total organic carbon inside aggregates, with regard to soil recovery, under 3 different soil management systems, i.e. 10 and 20 years of no-tillage cultivation as compared with soil under natural vegetation (Cerrado). Undisturbed soils (0-5; 5-10; and 10-20 cm depth) were collected from Brazil, Central Region. The soils, Oxisols from Cerrado, were collected from a field under Natural Vegetation-Cerrado (NV), and from fields that were under conventional tillage since 1970s, and 10 and 20 years ago were changed to no-tillage cultivation system (NT-10; NT-20 respectively). The undisturbed samples were sieved (4mm) and the aggregates retained were further fractionated by wet sieving through five sieves (2000, 1000, 500, 250, and 50 μm) with the aggregates distribution expressed as percentage retained by each sieve. The TOC was determined, for each aggregate size, by combustion (Thermo-Finnigan). A predominance of aggregates >2000 μm was observed under NV treatment (92, 91, 82 %), NT-10 (64, 73, 61 %), and NT-20 (71, 79, 63 %) for all three depths (0-5; 5-10; 10-20 cm). In addition greater quantities of aggregates in sizes 1000, 500, 250 and 50 μm under NT-10 and NT-20 treatments, explain the lower aggregate stability under these treatments compared to the soil under NV. The organic C concentration for NV in aggregates >2000 μm was 24,4; 14,2; 8,7 mg/g for each depth (0-5; 5-10; 10-20 cm, respectively), higher than in aggregates sized 250-50 μm (7,2; 5,5; 4,4 mg/g) for all depths

  17. Soil-Carbon Measurement System Based on Inelastic Neutron Scattering

    International Nuclear Information System (INIS)

    Orion, I.; Wielopolski, L.

    2002-01-01

    Increase in the atmospheric CO 2 is associated with concurrent increase in the amount of carbon sequestered in the soil. For better understanding of the carbon cycle it is imperative to establish a better and extensive database of the carbon concentrations in various soil types, in order to develop improved models for changes in the global climate. Non-invasive soil carbon measurement is based on Inelastic Neutron Scattering (INS). This method has been used successfully to measure total body carbon in human beings. The system consists of a pulsed neutron generator that is based on D-T reaction, which produces 14 MeV neutrons, a neutron flux monitoring detector and a couple of large NaI(Tl), 6'' diameter by 6'' high, spectrometers [4]. The threshold energy for INS reaction in carbon is 4.8 MeV. Following INS of 14 MeV neutrons in carbon 4.44 MeV photons are emitted and counted during a gate pulse period of 10 μsec. The repetition rate of the neutron generator is 104 pulses per sec. The gamma spectra are acquired only during the neutron generator gate pulses. The INS method for soil carbon content measurements provides a non-destructive, non-invasive tool, which can be optimized in order to develop a system for in field measurements

  18. Total observed organic carbon (TOOC in the atmosphere: a synthesis of North American observations

    Directory of Open Access Journals (Sweden)

    C. L. Heald

    2008-04-01

    Full Text Available Measurements of organic carbon compounds in both the gas and particle phases made upwind, over and downwind of North America are synthesized to examine the total observed organic carbon (TOOC in the atmosphere over this region. These include measurements made aboard the NOAA WP-3 and BAe-146 aircraft, the NOAA research vessel Ronald H. Brown, and at the Thompson Farm and Chebogue Point surface sites during the summer 2004 ICARTT campaign. Both winter and summer 2002 measurements during the Pittsburgh Air Quality Study are also included. Lastly, the spring 2002 observations at Trinidad Head, CA, surface measurements made in March 2006 in Mexico City and coincidentally aboard the C-130 aircraft during the MILAGRO campaign and later during the IMPEX campaign off the northwestern United States are incorporated. Concentrations of TOOC in these datasets span more than two orders of magnitude. The daytime mean TOOC ranges from 4.0 to 456 μgC m−3 from the cleanest site (Trinidad Head to the most polluted (Mexico City. Organic aerosol makes up 3–17% of this mean TOOC, with highest fractions reported over the northeastern United States, where organic aerosol can comprise up to 50% of TOOC. Carbon monoxide concentrations explain 46 to 86% of the variability in TOOC, with highest TOOC/CO slopes in regions with fresh anthropogenic influence, where we also expect the highest degree of mass closure for TOOC. Correlation with isoprene, formaldehyde, methyl vinyl ketone and methacrolein also indicates that biogenic activity contributes substantially to the variability of TOOC, yet these tracers of biogenic oxidation sources do not explain the variability in organic aerosol observed over North America. We highlight the critical need to develop measurement techniques to routinely detect total gas phase VOCs, and to deploy comprehensive suites of TOOC instruments in diverse environments to quantify the ambient evolution of organic carbon from source

  19. Investigation into Total Carbon in Sewage Sludge and Compost

    Directory of Open Access Journals (Sweden)

    Eglė Zuokaitė

    2011-02-01

    Full Text Available The relation between soil and climate change is highly important. The soil is a part of the climate change problem; however, it could also be a part of the solution to the encountered problem. For a better understanding and estimation of climate gas emissions and for slowing down these processes, more investigation in this field is required. Sustainable soil usage could help with saving or even increasing the amount of carbon in the soil. Such process will sustain the balance of climate gas emissions. Soil carbon is an essential element that determines soil fertility. Recently, the importance of organic materials for soil quality and the applicability of sewage sludge to enrich the soil using such materials have been discussed. Sewage sludge as an organic carbon source can improve soil quality. The best way to stabilise and immobilise carbon is mineralisation that occurs in the composting process. The article analyses and evaluates the loss of organic carbon content during the composting process of sewage sludge and explores loss rates by adding various natural supplements (wood shavings and chips, milled bark, grained branches, peat and zeolite.Article in Lithuanian

  20. Positron interactions with water–total elastic, total inelastic, and elastic differential cross section measurements

    International Nuclear Information System (INIS)

    Tattersall, Wade; Chiari, Luca; Machacek, J. R.; Anderson, Emma; Sullivan, James P.; White, Ron D.; Brunger, M. J.; Buckman, Stephen J.; Garcia, Gustavo; Blanco, Francisco

    2014-01-01

    Utilising a high-resolution, trap-based positron beam, we have measured both elastic and inelastic scattering of positrons from water vapour. The measurements comprise differential elastic, total elastic, and total inelastic (not including positronium formation) absolute cross sections. The energy range investigated is from 1 eV to 60 eV. Comparison with theory is made with both R-Matrix and distorted wave calculations, and with our own application of the Independent Atom Model for positron interactions

  1. Measurements of total OH reactivity during PROPHET-AMOS 2016

    Science.gov (United States)

    Rickly, P.; Sakowski, J.; Bottorff, B.; Lew, M.; Stevens, P. S.; Sklaveniti, S.; Locoge, N.; Dusanter, S.

    2017-12-01

    As one of the main oxidant in the atmosphere, the hydroxyl radical (OH) initiates the oxidation of volatile organic compounds that can lead to the formation of ozone and secondary organic aerosols. Understanding both the sources and sinks of OH is therefore important to address issues related to air quality and climate change. Measurements of total OH reactivity can provide an important test of our understanding of the OH radical budget. Recent measurements of total reactivity in many environments have been greater than calculated based on the measured concentration of VOCs, suggesting that important OH sinks in these environments are not well characterized. Measurements of total OH reactivity were performed in a forested environment during the PROPHET - AMOS field campaign (Program for Research on Oxidants: PHotochemisty, Emissions, and Transport - Atmospheric Measurements of Oxidants in Summer) using the Comparative Reactivity Method (CRM) and the Total OH Loss Rate Method (TOHLM). The site is characterized by large emissions of isoprene and monoterpenes and low anthropogenic influence. Measurements of total OH reactivity using these two techniques agree to within their respective uncertainties, giving confidence in the measured OH reactivity. In addition, measurements of trace gases (VOCs, NOx, O3) were used to perform a comprehensive apportionment of OH sinks. These measurements are used in a chemical model using the Master Chemical Mechanism to calculate the expected OH reactivity. The results will be compared to previous measurements of total OH reactivity at this site.

  2. Carbon fiber content measurement in composite

    Science.gov (United States)

    Wang, Qiushi

    Carbon fiber reinforced polymers (CFRPs) have been widely used in various structural applications in industries such as aerospace and automotive because of their high specific stiffness and specific strength. Their mechanical properties are strongly influenced by the carbon fiber content in the composites. Measurement of the carbon fiber content in CFRPs is essential for product quality control and process optimization. In this work, a novel carbonization-in-nitrogen method (CIN) is developed to characterize the fiber content in carbon fiber reinforced thermoset and thermoplastic composites. In this method, a carbon fiber composite sample is carbonized in a nitrogen environment at elevated temperatures, alongside a neat resin sample. The carbon fibers are protected from oxidization while the resin (the neat resin and the resin matrix in the composite sample) is carbonized under the nitrogen environment. The residue of the carbonized neat resin sample is used to calibrate the resin carbonization rate and calculate the amount of the resin matrix in the composite sample. The new method has been validated on several thermoset and thermoplastic resin systems and found to yield an accurate measurement of fiber content in carbon fiber polymer composites. In order to further understand the thermal degradation behavior of the high temperature thermoplastic polymer during the carbonization process, the mechanism and the kinetic model of thermal degradation behavior of carbon fiber reinforced poly (phenylene sulfide) (CPPS) are studied using thermogravimetry analysis (TGA). The CPPS is subjected to TGA in an air and nitrogen atmosphere at heating rates from 5 to 40°C min--1. The TGA curves obtained in air are different from those in nitrogen. This demonstrates that weight loss occurs in a single stage in nitrogen but in two stages in air. To elucidate this difference, thermal decomposition kinetics is analyzed by applying the Kissinger, Flynn-Wall-Ozawa, Coat-Redfern and

  3. a locally adapted functional outcome measurement score for total

    African Journals Online (AJOL)

    Results and success of total hip arthroplasty are often measured using a functional outcome scoring system. Most current scores were developed in Europe and. North America (1-3). During the evaluation of a Total. Hip Replacement (THR) project in Ouagadougou,. Burkina Faso (4) it was felt that these scores were not.

  4. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-01-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study. PMID:6639023

  5. Assessment of bacterial growth and total organic carbon removal on granular activated carbon contactors.

    Science.gov (United States)

    Bancroft, K; Maloney, S W; McElhaney, J; Suffet, I H; Pipes, W O

    1983-09-01

    The overall growth rate of bacteria on granular activated carbon (GAC) contactors at the Philadelphia Torresdale Water Treatment Pilot Plant facility was found to decrease until steady state was reached. The growth rate was found to fluctuate between 6.94 X 10(-3) and 8.68 X 10(-4) doublings per h. The microbiological removal of total organic carbon (TOC) was calculated by considering the GAC contactors as semiclosed continuous culture systems and using growth yield factors determined in laboratory experiments. After ozonation, the average TOC entering the contactors was 1,488 micrograms/liter, and the average effluent TOC was 497 micrograms/liter. Microbiological TOC removal was found to average 240 micrograms/liter on GAC contactors, which was not significantly different from microbiological TOC (220 micrograms/liter) removal across a parallel sand contactor where no adsorption took place. Thus, GAC did not appear to enhance biological TOC removal. Bacterial growth and maintenance was responsible for approximately 24% of the TOC removal on GAC under the conditions of this study.

  6. Total ozone retrieval from satellite multichannel filter radiometer measurements

    International Nuclear Information System (INIS)

    Lovill, J.E.; Sullivan, T.J.; Weichel, R.L.; Ellis, J.S.; Huebel, J.G.; Korver, J.; Weidhaas, P.P.; Phelps, F.A.

    1978-01-01

    A total ozone retrieval model has been developed to process radiance data gathered by a satellite-mounted multichannel filter radiometer (MFR). Extensive effort went into theoretical radiative transfer modeling, a retrieval scheme was developed, and the technique was applied to the MFR radiance measurements. The high quality of the total ozone retrieval results was determined through comparisons with Dobson measurements. Included in the report are global total ozone maps for 20 days between May 12 and July 5, 1977. A comparison of MFR results for 13 days in June 1977 with Dobson spectrophotometer measurements of ozone for the same period showed good agreement: there was a root-mean-square difference of 6.2% (equivalent to 20.2 m.atm.cm). The estimated global total ozone value for June 1977 (296 m.atm.cm) was in good agreement with satellite backscatter ultraviolet data for June 1970 (304 m.atm.cm) and June 1971

  7. Total Flavonoids from Mimosa Pudica Protects Carbon Tetrachloride -Induced Acute Liver Injury in Mice

    Directory of Open Access Journals (Sweden)

    Zhen-qin QIU

    2015-03-01

    Full Text Available Objective: To observe the protective effect of total flavonoids from Mimosa pudica on carbon tetrachloride (CCl4-induced acute liver injury in mice. Methods: CCl4-induced acute liver injury model in mice was established. The activity of ALT and AST, the content of serum albumin (Alb and total antioxidant capacity (T-AOC were determined. The content of malondiadehyde (MDA was measured and the activity of superoxide dismutase (SOD was determined. The histopathological changes of liver were observed.Results: Compared with CCl4 modle group, each dose group of total flavonouida from Mimosa pudica couldreduced the activity of ALT and AST in mice obviously (P<0.01, indicating they had remarkably protective effect on CCl4-induced acute liver injury in mice. high and middle dose groups of total flavonouida from Mimosa pudica couldincrease the content of Alb in mice (P<0.01. Each dose group of total flavonouida from Mimosa pudica could enhance the level of T-AOC (P<0.01. each dose group of total flavonouida from Mimosa pudica could lower the content of liver homogenate MDA but enhance the activity of SOD in a dose-depended manner (P<0.01. Conclusion: Total flavones from Mimosa Pudica have obvious protective effect on CCl4-induced acute liver injury in mice.

  8. Progress on FP13 Total Cross Section Measurements Capability

    Energy Technology Data Exchange (ETDEWEB)

    Ullmann, John Leonard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Couture, Aaron Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Koehler, Paul E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mosby, Shea Morgan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-26

    An accurate knowledge of the neutron capture cross section is important for many applications. Experimental measurements are important since theoretical calculations of capture have been notoriously difficult, with the ratio of measured to calculated cross sections often a factor of 2 or more in the 10 keV to 1 MeV region. However, a direct measurement of capture cannot be made on many interesting radioactive nuclides because of their short half-life or backgrounds caused by their nuclear decay. On the other hand, neutron transmission measurements of the total cross section are feasible for a wide range of radioactive nuclides since the detectors are far from the sample, and often are less sensitive to decay radiation. The parameters extracted from a total cross section measurement, which include the average resonance spacing, the neutron strength function, and the average total radiation width, (Γγ), provide tight constraints on the calculation of the capture cross section, and when applied produce much more accurate results. These measurements can be made using the intense epithermal neutron flux at the Lujan Center on relatively small quantities of target material. It was the purpose of this project to investigate and develop the capability to make these measurements. A great deal of progress was made towards establishing this capability during 2016, including setting up the flight path and obtaining preliminary results, but more work remains to be done.

  9. Determination of total ozone from DMSP multichannel filter radiometer measurements

    International Nuclear Information System (INIS)

    Luther, F.M.; Weichel, R.L.

    1992-01-01

    The multichannel filter radiometer (MFR) infrared sensor was first flown in 1977 on a Defense Meteorological Satellite Program (DMSP) Block 5D series satellite operated by the US Air Force. The first four satellites in this series carried MFR sensors from which total atmospheric column ozone amounts may be derived. The MFR sensor was the first cross-track scanning sensor capable of measuring ozone. MFR sensor infrared measurements are taken day and night. The satellites are in polar sun-synchronous orbits providing daily global coverage. The series of four sensors spans a data period of nearly three years. The MFR sensor measures infrared radiances for 16 channels. Total ozone amounts are determined from sets of radiance measurements using an empirical relationship that is developed using linear regression analysis. Total ozone is modeled as a linear combination of terms involving functions of the MFR radiances for four channels (1, 3, 7 and 16) and the secant of the zenith angle. The MFR scans side to side in discrete steps of 40. The MFR sensor takes infrared radiance measurements at 25 cross-track scanning locations every 32 seconds. The instrument could take a theoretical maximum of 67,500 measurements per day, although typically 35,000 - 45,000 measurements are taken per day

  10. Online total organic carbon (TOC) monitoring for water and wastewater treatment plants processes and operations optimization

    Science.gov (United States)

    Assmann, Céline; Scott, Amanda; Biller, Dondra

    2017-08-01

    Organic measurements, such as biological oxygen demand (BOD) and chemical oxygen demand (COD) were developed decades ago in order to measure organics in water. Today, these time-consuming measurements are still used as parameters to check the water treatment quality; however, the time required to generate a result, ranging from hours to days, does not allow COD or BOD to be useful process control parameters - see (1) Standard Method 5210 B; 5-day BOD Test, 1997, and (2) ASTM D1252; COD Test, 2012. Online organic carbon monitoring allows for effective process control because results are generated every few minutes. Though it does not replace BOD or COD measurements still required for compliance reporting, it allows for smart, data-driven and rapid decision-making to improve process control and optimization or meet compliances. Thanks to the smart interpretation of generated data and the capability to now take real-time actions, municipal drinking water and wastewater treatment facility operators can positively impact their OPEX (operational expenditure) efficiencies and their capabilities to meet regulatory requirements. This paper describes how three municipal wastewater and drinking water plants gained process insights, and determined optimization opportunities thanks to the implementation of online total organic carbon (TOC) monitoring.

  11. Measuring Biomass and Carbon Stock in Resprouting Woody Plants

    Science.gov (United States)

    Matula, Radim; Damborská, Lenka; Nečasová, Monika; Geršl, Milan; Šrámek, Martin

    2015-01-01

    Resprouting multi-stemmed woody plants form an important component of the woody vegetation in many ecosystems, but a clear methodology for reliable measurement of their size and quick, non-destructive estimation of their woody biomass and carbon stock is lacking. Our goal was to find a minimum number of sprouts, i.e., the most easily obtainable, and sprout parameters that should be measured for accurate sprout biomass and carbon stock estimates. Using data for 5 common temperate woody species, we modelled carbon stock and sprout biomass as a function of an increasing number of sprouts in an interaction with different sprout parameters. The mean basal diameter of only two to five of the thickest sprouts and the basal diameter and DBH of the thickest sprouts per stump proved to be accurate estimators for the total sprout biomass of the individual resprouters and the populations of resprouters, respectively. Carbon stock estimates were strongly correlated with biomass estimates, but relative carbon content varied among species. Our study demonstrated that the size of the resprouters can be easily measured, and their biomass and carbon stock estimated; therefore, resprouters can be simply incorporated into studies of woody vegetation. PMID:25719601

  12. ORGANIC CARBON AND TOTAL NITROGEN IN THE DENSIMETRIC FRACTIONS OF ORGANIC MATTER UNDER DIFFERENT SOIL MANAGEMEN

    Directory of Open Access Journals (Sweden)

    MARCELO RIBEIRO VILELA PRADO

    2016-01-01

    Full Text Available The evaluation of land use and management by the measurement of soil organic matter and its fractions has gained attention since it helps in the understanding of the dynamics of their contribution to soil productivity, especially in tropical environments. This study was conducted in the municipality of Colorado do Oeste, state of Rondônia, Brazil and its aim was to determinethe quantity of organic carbon and total nitrogen in the light and heavy fractions of organic matter in the surface layers of a typic hapludalf under different land use systems: Native Forest: open evergreen forest, reference environment; Agroforestry System 1: teak (Tectona grandis LF and kudzu (Pueraria montana; Agroforestry System 2: coffee (Coffea canephora, marandu palisade grass (Brachiaria brizantha cv. Marandu, “pinho cuiabano” (Parkia multijuga, teak and kudzu.; Agroforestry System 3: teak and cocoa (Theobroma cacao; Silvopasture System: teak, cocoa and marandu palisade grass; and Extensive Grazing System: marandu palisade grass. The experimental design was a randomized block in split-split plots (use systems versus soil layers of 0-0.05 and 0.05-0.10 m with three replications. The results showed that relative to Native Forest, the Agroforestry System 2 had equal- and greater amounts of organic carbon and total nitrogen respectively (light and heavy fractions in the soil organic matter, with the light fraction being responsible for storage of approximately 45% and 70% of the organic carbon and total nitrogen, respectively. Therefore, the light densimetric fraction proved to be useful in the early identification of the general decline of the soil organic matter in the land use systems evaluated.

  13. Neutron total cross section measurements on 249Cf

    International Nuclear Information System (INIS)

    Carlton, R.F.; Harvey, J.A.; Hill, N.W.; Pandey, M.S.; Benjamin, R.W.

    1979-01-01

    Neutron total cross section measurements were performed on a sample of 249 Cf (5.65 mg total weight) with the ORELA as a source of pulsed neutrons. The sample, the inverse thickness of which was 1542 barns/atom, consisted of 85.3% 249 Cf and 14.4% 249 Bk, and was cooled to liquid nitrogen temperature. Analyses were also made of data from a thin sample (l/n = 17430) of 65% 249 Cf in the region of the large fission resonance at 0.7 eV. Fifty-five resonances in 249 Cf were observed and analyzed over the energy range 0.1 eV to 90 eV by use of an R-matrix multilevel formalism. The resonance parameters obtained were used to determine the level spacing and the s-wave neutron and fission strength functions. Thermal total cross section measurements were also performed. 5 figures, 3 tables

  14. Total and size-resolved particle number and black carbon concentrations in urban areas near Schiphol airport (the Netherlands)

    NARCIS (Netherlands)

    Keuken, M.P.; Moerman, M.; Zandveld, P.; Henzing, J.S.; Hoek, G.

    2015-01-01

    The presence of black carbon, and size-resolved and total particle number concentrations (PNC) were investigated in the vicinity of Schiphol airport in the Netherlands, the fourth busiest airport in Europe. Continuous measurements were conducted between March and May 2014at Adamse Bos, located 7km

  15. Carbon monoxide reduces near-infrared spectroscopy determined 'total' hemoglobin

    DEFF Research Database (Denmark)

    Niemann, Mads J; Sørensen, Henrik; Siebenmann, Christoph

    2017-01-01

    with CO (1.5 mL kg-1) was added to the circuit. Two NIRS systems (NIRO-200NX and INVOS-5100) assessed ScO2 as the ratio of oxygenated to deoxygenated hemoglobin, while venous blood samples were analyzed for carboxyhemoglobin (COHb). After CO/O2 rebreathing COHb increased to 8.7% (IQR; 7.9-9.4; p = .004...... to normoxia (68.9 ± 6.9%; p hemoglobin decreased (by 19.7 μM (median; IQR 2.8-34.8; p = .016) and 37.3 μM (30.8-46.6; p = .004), respectively) during inhalation of CO/O2 compared...... to inhalation of O2. Therefore, NIRO-200NX determined 'total' hemoglobin (sum of O2Hb and HHb) decreased (by 62.1 μM; 44.5-78.2; p = .001). In conclusion, exposure to CO did not increase MCAVmean, and neither NIRO-200NX nor INVOS-5100 detected a change in ScO2 when CO was added to inhalation of oxygen...

  16. Total cross-section measurements progress in nuclear physics

    CERN Document Server

    Giacomelli, G; Mulvey, J H

    2013-01-01

    Total Cross-Section Measurements discusses the cross-sectional dimensions of elementary hadron collisions. The main coverage of the book is the resonance and high energy area of the given collision. A section of the book explains in detail the characteristic of a resonance region. Another section is focused on the location of the high energy region of collision. Parts of the book define the meaning of resonance in nuclear physics. Also explained are the measurement of resonance and the identification of the area where the resonance originates. Different experimental methods to measure the tota

  17. Carbon potential measurement on some actinide carbides

    International Nuclear Information System (INIS)

    Anthonysamy, S.; Ananthasivan, K.; Kaliappan, I.; Chandramouli, V.; Vasudeva Rao, P.R.; Mathews, C.K.; Jacob, K.T.

    1994-01-01

    Uranium-Plutonium mixed carbides with a Pu/(U+Pu) ratio of 0.55 are to be used as the fuel in the Fast Breeder Test Reactor (FBTR) at Kalpakkam, India. Carburization of the stainless steel clad by this fuel is determined by its carbon potential. Because the carbon potential of this fuel composition is not available in the literature, it was measured by the methane-hydrogen gas equilibration technique. The sample was equilibrated with purified hydrogen and the equilibrium methane-to-hydrogen ratio in the gas phase was measured with a flame ionization detector. The carbon potential of the ThC-ThC 2 as well as Mo-Mo 2 C system, which is an important binary in the actinide-fission product-carbon systems, were also measured by this technique in the temperature range 973 to 1,173 K. The data for the Mo-Mo 2 C system are in agreement with values reported in the literature. The results for the ThC-ThC 2 system are different from estimated values with large uncertainty limits given in the literature. The data on (U, Pu) mixed carbides indicates the possibility of stainless steel clad attack under isothermal equilibrium conditions

  18. Secondary standard neutron detector for measuring total reaction cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Gabbard, F.

    1975-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron-production cross sections. The detector consists of a polyethylene sphere of 24'' diameter in which 8- 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies, from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p,n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p,n) 51 Cr and 57 Fe(p,n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for measurement of total neutron yields from neutron producing reactions such as 23 Na(p,n) 23 Mg are given

  19. Total OH Reactivity Measurements in the Boreal Forest

    Science.gov (United States)

    Praplan, A. P.; Hellén, H.; Hakola, H.; Hatakka, J.

    2015-12-01

    INTRODUCTION Atmospheric total OH reactivity (Rtotal) can be measured (Kovacs and Brune, 2001; Sinha et al., 2008) or it can be calculated according to Rtotal = ∑i kOH+X_i [Xi] where kOH+X_i corresponds to the reaction rate coefficient for the reaction of OH with a given compound Xi and [Xi] its concentration. Studies suggest that in some environments a large fraction of missing reactivity, comparing calculated Rtotal with ambient total OH reactivity measurements (Di Carlo et al., 2004; Hofzumahaus et al., 2009). In this study Rtotal has been measured using the Comparative Reactivity Method (Sinha et al., 2008). Levels of the reference compound (pyrrole, C4H5N) are monitored by gas chromatography every 2 minutes and Rtotal is derived from the difference of reactivity between zero and ambient air. RESULTS Around 36 hours of preliminary total OH reactivity data (30 May until 2 June 2015) are presented in Fig. 1. Its range matches previous studies for this site (Nölscher et al., 2012; Sinha et al., 2010) and is similar to values in another pine forest (Nakashima et al., 2014). The setup used during the period presented here has been updated and more recent data will be presented, as well as a comparison with calculated OH reactivity from measured individual species. ACKNOWLEDGEMENTS This work was supported by Academy of Finland (Academy Research Fellowship No. 275608). The authors acknowledge Juuso Raine for technical support. REFERENCES Di Carlo et al. (2004). Science 304, 722-725.Hofzumahaus et al. (2009). Science 324, 1702-1704.Kovacs and Brune (2001). J. Atmos. Chem. 39, 105-122.Nakashima et al. (2014). Atmos. Env. 85, 1-8.Nölscher et al. (2012). Atmos. Chem. Phys. 12, 8257-8270.Sinha et al. (2008). Atmos. Chem. Phys. 8, 2213-2227.Sinha et al. (2010). Environ. Sci. Technol. 44, 6614-6620.

  20. Integrated Data Fusion and Mining Techniques for Monitoring Total Organic Carbon Concentrations in a Lake

    Science.gov (United States)

    Total organic carbon (TOC) in surface waters, markedly of seasonal variations, is a known precursor of disinfection byproducts such as Total Trihalomethanes (TTHM) in drinking water treatment. Real-time knowledge of TOC distribution in source water can help treatment operation to...

  1. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  2. Measuring Carbon Emissions of Pavement Construction in China

    Directory of Open Access Journals (Sweden)

    Youliang Huang

    2016-07-01

    Full Text Available While various methodologies for quantifying carbon emissions of pavement construction are developed worldwide, adopting and promoting the existing tools to China’s market is found fairly challenging due to institutional constraints. Therefore, the objectives of this study are to propose a methodology for measuring carbon emissions of pavement construction compatible with the fixed pricing systems prevalent in China; and develop an automatic tool for carbon estimations. The total carbon emissions are measured by aggregating emissions of energy consumption and materials used along with four stages, namely material manufacture, transportation, construction, and disposal. A set of composite carbon emission factors for energy and materials was calculated based on existing emission factors with the consideration of the boundaries concerned. The quantity of energy and materials used in pavement construction are obtained through bills of quantity and the fixed price system. The database of the emission factors for energy and materials was embedded into a C# based tool, and validated in a real case.

  3. Radioimmunological measurements of total LH in sheep pituitary cells

    International Nuclear Information System (INIS)

    McIntosh, R.P.; McIntosh, J.E.A.

    1983-01-01

    Procedures commonly used to extract LH from pituitary cells in order to measure total cell content were compared in four cell preparations. It was shown in 81 samples of cells suspended in 1 mM EDTA or 50 mM NaHCO 3 that after freezing and thawing folloqwed by any of a variety of treatments, there were no significant differences in the amounts of LH measured by RIA relative to the arbitrarily chosen reference treatment of vigorous pipetting. The additional treatments were multiple freezing and thawing, homogenisation, sonication, homogenisation in 25-100 mM Na 2 CO 3 folloqwed by rapid neutralisation, or none. The consistency of the results suggested that the same cellular pools of LH were being made accessible for measurement with all treatments. However, use of the more vigorous conditions of 1-2.5 M urea, 1% Triton X-100, or sonication on ice in 100 mM Na 2 CO 3 decreased the amount of measurable hormone presumably due to its modification. In two cell preparations, homogenisation of cells in 100 mM Na 2 CO 3 produced and additional 45% of measurable LH not accessible using other treatments nor from the source material in two other preparations. (author)

  4. Total organic carbon, an important tool in an holistic approach to hydrocarbon source fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, P.D.; Burns, W.A.; Page, D.S.; Bence, A.E.; Mankiewicz, P.J.; Brown, J.S.; Douglas, G.S. [Battelle Member Inst., Waltham, MA (United States)

    2002-07-01

    The identification and allocation of multiple hydrocarbon sources in marine sediments is best achieved using an holistic approach. Total organic carbon (TOC) is one important tool that can constrain the contributions of specific sources and rule out incorrect source allocations in cases where inputs are dominated by fossil organic carbon. In a study of the benthic sediments from Prince William Sound (PWS) and the Gulf of Alaska (GOA), we find excellent agreement between measured TOC and TOC calculated from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. Confirmation by two such independent source indicators (TOC and fingerprint matches) provides evidence that source allocations determined by the fingerprint matches are robust and that the major TOC sources have been correctly identified. Fingerprint matches quantify the hydrocarbon contributions of various sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. TOC contents are then calculated using source allocation results from fingerprint matches and the TOCs of contributing sources. Comparisons of the actual sediment TOC values and those calculated from source allocation support our earlier published findings that the natural petrogenic hydrocarbon background in sediments in this area comes from eroding Tertiary shales and associated oil seeps along the northern GOA coast and exclude thermally mature area coals from being important contributors to the PWS background due to their high TOC content.

  5. Carbon pool densities and a first estimate of the total carbon pool in the Mongolian forest-steppe.

    Science.gov (United States)

    Dulamsuren, Choimaa; Klinge, Michael; Degener, Jan; Khishigjargal, Mookhor; Chenlemuge, Tselmeg; Bat-Enerel, Banzragch; Yeruult, Yolk; Saindovdon, Davaadorj; Ganbaatar, Kherlenchimeg; Tsogtbaatar, Jamsran; Leuschner, Christoph; Hauck, Markus

    2016-02-01

    The boreal forest biome represents one of the most important terrestrial carbon stores, which gave reason to intensive research on carbon stock densities. However, such an analysis does not yet exist for the southernmost Eurosiberian boreal forests in Inner Asia. Most of these forests are located in the Mongolian forest-steppe, which is largely dominated by Larix sibirica. We quantified the carbon stock density and total carbon pool of Mongolia's boreal forests and adjacent grasslands and draw conclusions on possible future change. Mean aboveground carbon stock density in the interior of L. sibirica forests was 66 Mg C ha(-1) , which is in the upper range of values reported from boreal forests and probably due to the comparably long growing season. The density of soil organic carbon (SOC, 108 Mg C ha(-1) ) and total belowground carbon density (149 Mg C ha(-1) ) are at the lower end of the range known from boreal forests, which might be the result of higher soil temperatures and a thinner permafrost layer than in the central and northern boreal forest belt. Land use effects are especially relevant at forest edges, where mean carbon stock density was 188 Mg C ha(-1) , compared with 215 Mg C ha(-1) in the forest interior. Carbon stock density in grasslands was 144 Mg C ha(-1) . Analysis of satellite imagery of the highly fragmented forest area in the forest-steppe zone showed that Mongolia's total boreal forest area is currently 73 818 km(2) , and 22% of this area refers to forest edges (defined as the first 30 m from the edge). The total forest carbon pool of Mongolia was estimated at ~ 1.5-1.7 Pg C, a value which is likely to decrease in future with increasing deforestation and fire frequency, and global warming. © 2015 John Wiley & Sons Ltd.

  6. A new automated colorimetric method for measuring total oxidant status.

    Science.gov (United States)

    Erel, Ozcan

    2005-12-01

    To develop a new, colorimetric and automated method for measuring total oxidation status (TOS). The assay is based on the oxidation of ferrous ion to ferric ion in the presence of various oxidant species in acidic medium and the measurement of the ferric ion by xylenol orange. The oxidation reaction of the assay was enhanced and precipitation of proteins was prevented. In addition, autoxidation of ferrous ion present in the reagent was prevented during storage. The method was applied to an automated analyzer, which was calibrated with hydrogen peroxide and the analytical performance characteristics of the assay were determined. There were important correlations with hydrogen peroxide, tert-butyl hydroperoxide and cumene hydroperoxide solutions (r=0.99, Ptotal antioxidant capacity (TAC) (r=-0.66 Ptotal oxidant status.

  7. Quantitative analysis of SCIAMACHY carbon monoxide total column measurements

    NARCIS (Netherlands)

    Laat, de A.T.J.; Gloudemans, A.M.S.; Schrijver, H.; Broek, van den M.M.P.; Meirink, J.F.; Aben, I.; Krol, M.C.

    2006-01-01

    Global tropospheric ozone distributions, budgets, and radiative forcings from an ensemble of 26 state-of-the-art atmospheric chemistry models have been intercompared and synthesized as part of a wider study into both the air quality and climate roles of ozone. Results from three 2030 emissions

  8. Automated determination of the stable carbon isotopic composition (δ13C) of total dissolved inorganic carbon (DIC) and total nonpurgeable dissolved organic carbon (DOC) in aqueous samples: RSIL lab codes 1851 and 1852

    Science.gov (United States)

    Révész, Kinga M.; Doctor, Daniel H.

    2014-01-01

    The purposes of the Reston Stable Isotope Laboratory (RSIL) lab codes 1851 and 1852 are to determine the total carbon mass and the ratio of the stable isotopes of carbon (δ13C) for total dissolved inorganic carbon (DIC, lab code 1851) and total nonpurgeable dissolved organic carbon (DOC, lab code 1852) in aqueous samples. The analysis procedure is automated according to a method that utilizes a total carbon analyzer as a peripheral sample preparation device for analysis of carbon dioxide (CO2) gas by a continuous-flow isotope ratio mass spectrometer (CF-IRMS). The carbon analyzer produces CO2 and determines the carbon mass in parts per million (ppm) of DIC and DOC in each sample separately, and the CF-IRMS determines the carbon isotope ratio of the produced CO2. This configuration provides a fully automated analysis of total carbon mass and δ13C with no operator intervention, additional sample preparation, or other manual analysis. To determine the DIC, the carbon analyzer transfers a specified sample volume to a heated (70 °C) reaction vessel with a preprogrammed volume of 10% phosphoric acid (H3PO4), which allows the carbonate and bicarbonate species in the sample to dissociate to CO2. The CO2 from the reacted sample is subsequently purged with a flow of helium gas that sweeps the CO2 through an infrared CO2 detector and quantifies the CO2. The CO2 is then carried through a high-temperature (650 °C) scrubber reactor, a series of water traps, and ultimately to the inlet of the mass spectrometer. For the analysis of total dissolved organic carbon, the carbon analyzer performs a second step on the sample in the heated reaction vessel during which a preprogrammed volume of sodium persulfate (Na2S2O8) is added, and the hydroxyl radicals oxidize the organics to CO2. Samples containing 2 ppm to 30,000 ppm of carbon are analyzed. The precision of the carbon isotope analysis is within 0.3 per mill for DIC, and within 0.5 per mill for DOC.

  9. Method for obtaining more precise measures of excreted organic carbon

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    A new method for concentrating and measuring excreted organic carbon by lyophilization and scintillation counting is efficient, improves measurable radioactivity, and increases precision for estimates of organic carbon excreted by phytoplankton and macrophytes

  10. Effect of TOC [total organic carbon] on a PWR secondary cooling water system

    International Nuclear Information System (INIS)

    Gau, J.Y.; Oung, J.C.; Wang, T.Y.

    1989-01-01

    Increasing the amount of total organic carbon (TOC) during the wet layup of the steam generator was a problem in PWR nuclear power plant in Taiwan. The results of surveys of TOC in PWR secondary cooling water systems had shown that the impurity of hydrazine and the bacteria were the main reasons that increase TOC. These do not have a corrosion effect on Inconel 600 and carbon steel when the secondary cooling water containing the TOC is below 200 ppb. But the anaerobic bacteria from the steam generator in wet layup will increase corrosion rate of carbon steel and crevice corrosion of Inconel 600. (author)

  11. Measuring and understanding total dissolved gas pressure in groundwater

    Science.gov (United States)

    Ryan, C.; Roy, J. W.; Randell, J.; Castellon, L.

    2009-05-01

    Since dissolved gases are important to a number of aspects of groundwater (e.g. age dating, active or passive bioremediation, greenhouse gas fluxes, understanding biogeochemical processes involving gases, assessing potential impacts of coal bed methane activities), accurate concentration measurements, and understanding of their subsurface behaviour are important. Researchers have recently begun using total dissolved gas pressure (TGP) sensor measurements, more commonly applied for surface water monitoring, in concert with gas composition analyses to estimate more accurate groundwater gas concentrations in wells. We have used hydraulic packers to isolate the well screens where TDP is being measured, and pump tests to indicate that in-well degassing may reduce TDG below background groundwater levels. Thus, in gas-charged groundwater zones, TGPs can be considerably underestimated in the absence of pumping or screen isolation. We have also observed transient decreased TGPs during pumping that are thought to result from ebullition induced when the water table or water level in the well is lowered below a critical hydrostatic pressure.

  12. Quantifying Changes in Total and Pyrogenic Carbon Stocks Across Fire Severity Gradients Using Active Wildfire Incidents

    Directory of Open Access Journals (Sweden)

    Jessica Miesel

    2018-05-01

    Full Text Available Positive feedbacks between wildfire emissions and climate are expected to increase in strength in the future; however, fires not only release carbon (C from terrestrial to atmospheric pools, they also produce pyrogenic C (PyC which contributes to longer-term C stability. Our objective was to quantify wildfire impacts on total C and PyC stocks in California mixed-conifer forest, and to investigate patterns in C and PyC stocks and changes across gradients of fire severity, using metrics derived from remote sensing and field observations. Our unique study accessed active wildfires to establish and measure plots within days before and after fire, prior to substantial erosion. We measured pre- and post-fire aboveground forest structure and woody fuels to calculate aboveground biomass, C and PyC, and collected forest floor and 0–5 cm mineral soil samples. Immediate tree mortality increased with severity, but overstory C loss was minimal and limited primarily to foliage. Fire released 85% of understory and herbaceous C (comprising < 1.0% of total ecosystem C. The greatest C losses occurred from downed wood and forest floor pools (19.3 ± 5.1 Mg ha−1 and 25.9 ± 3.2 Mg ha−1, respectively. Tree bark and downed wood contributed the greatest PyC gains (1.5 ± 0.3 Mg ha−1 and 1.9 ± 0.8 Mg ha−1, respectively, and PyC in tree bark showed non-significant positive trends with increasing severity. Overall PyC losses of 1.9 ± 0.3 Mg ha−1 and 0.5 ± 0.1 Mg ha−1 occurred from forest floor and 0–5 cm mineral soil, with no clear patterns across severity. Fire resulted in a net ecosystem PyC gain (1.0 ± 1.0 Mg ha−1 across aboveground and belowground components of these forests, and there were no differences among severity levels. Carbon emissions represented only 21.6% of total forest C; however, extensive conversion of C from live to dead pools will contribute to large downed wood C pools susceptible to release in a subsequent fire, indicating

  13. Carbon Valuation: Alternatives, Alternations and Lateral Measures?

    DEFF Research Database (Denmark)

    Dalsgaard, Steffen

    2016-01-01

    This article refers to carbon valuation as the practice of ascribing value to, and assessing the value of, actions and objects in terms of carbon emissions. Due to the pervasiveness of carbon emissions in the actions and objects of everyday lives of human beings, the making of carbon offsets and ...

  14. The Scale, Structure and Influencing Factors of Total Carbon Emissions from Households in 30 Provinces of China—Based on the Extended STIRPAT Model

    Directory of Open Access Journals (Sweden)

    Yong Wang

    2018-05-01

    assessment of the total carbon emissions of China’s households and provide a reasonable reference that the government can use to formulate energy-saving and emission-reduction measures.

  15. Total cross section measurements with π- , Σ- and protons on nuclei and nucleons around 600 GeV/c

    International Nuclear Information System (INIS)

    Dersch, U.; Akchurin, N.; Andreev, V.A.; Atamantchouk, A.G.; Aykac, M.; Balatz, M.Y.; Bondar, N.F.; Bravar, A.; Cooper, P.S.; Dauwe, L.J.; Davidenko, G.V.; Dirkes, G.; Dolgolenko, A.G.; Dreossi, D.; Dzyubenko, G.B.; Edelstein, R.; Emediato, L.; Endler, A.M.F.; Engelfried, J.; Eschrich, I.; Escobar, C.O.; Evdokimov, A.V.; Filimonov, I.S.; Garcia, F.G.; Gaspero, M.; Gerzon, S.; Giller, I.; Golovtsov, V.L.; Goncharenko, Y.M.; Gottschalk, E.; Gouffon, P.; Grachov, O.A.; Guelmez, E.; Kangling, He; Iori, M.; Jun, S.Y.; Kamenskii, A.D.; Kaya, M.; Kilmer, J.; Kim, V.T.; Kochenda, L.M.; Koenigsmann, K.; Konorov, I.; Kozhevnikov, A.P.; Krivshich, A.G.; Krueger, H.; Kubantsev, M.A.; Kubarovsky, V.P.; Kulyavtsev, A.I.; Kuropatkin, N.P.; Kurshetsov, V.F.; Kushnirenko, A.; Kwan, S.; Lach, J.; Lamberto, A.; Landsberg, L.G.; Larin, I.; Leikin, E.M.; Yunshan, Li; Zhigang, Li; Luksys, M.; Lungov, T.; Magarrel, D.; Maleev, V.P.; Mao, D.; Chensheng, Mao; Zhenlin, Mao; Masciocchi, S.; Mathew, P.; Mattson, M.; Matveev, V.; McCliment, E.; McKenna, S.L.; Moinester, M.A.; Molchanov, V.V.; Morelos, A.; Mukhin, V.A.; Nelson, K.D.; Nemitkin, A.V.; Neoustroev, P.V.; Newsom, C.; Nilov, A.P.; Nurushev, S.B.; Ocherashvili, A.; Oleynik, G.; Onel, Y.; Ozel, E.; Ozkorucuklu, S.; Patrichev, S.; Penzo, A.; Petrenko, S.I.; Pogodin, P.; Povh, B.; Procario, M.; Prutskoi, V.A.; Ramberg, E.; Rapazzo, G.F.; Razmyslovich, B.V.; Rud, V.I.; Russ, J.; Scheglov, Y.; Schiavon, P.; Semyatchkin, V.K.; Simon, J.; Sitnikov, A.I.; Skow, D.; Smith, V.J.; Srivastava, M.; Steiner, V.; Stepanov, V.; Stutte, L.; Svoiski, M.; Terentyev, N.K.; Thomas, G.P.; Uvarov, L.N.; Vasiliev, A.N.; Vavilov, D.V.; Verebryusov, V.S.; Victorov, V.A.; Vishnyakov, V.E.; Vorobyov, A.A.; Vorwalter, K.; You, J.; Wenheng, Zhao; Shuchen, Zheng; Zukanovich-Funchal, R.

    2000-01-01

    Total cross sections for Σ - and π - on beryllium, carbon, polyethylene and copper as well as total cross sections for protons on beryllium and carbon have been measured in a broad momentum range around 600 GeV/c . These measurements were performed with a transmission technique in the SELEX hyperon-beam experiment at Fermilab. We report on results obtained for hadron-nucleus cross sections and on results for σ tot (Σ - N) and σ tot (π - N) , which were deduced from nuclear cross sections

  16. Development of improved space sampling strategies for ocean chemical properties: Total carbon dioxide and dissolved nitrate

    Science.gov (United States)

    Goyet, Catherine; Davis, Daniel; Peltzer, Edward T.; Brewer, Peter G.

    1995-01-01

    Large-scale ocean observing programs such as the Joint Global Ocean Flux Study (JGOFS) and the World Ocean Circulation Experiment (WOCE) today, must face the problem of designing an adequate sampling strategy. For ocean chemical variables, the goals and observing technologies are quite different from ocean physical variables (temperature, salinity, pressure). We have recently acquired data on the ocean CO2 properties on WOCE cruises P16c and P17c that are sufficiently dense to test for sampling redundancy. We use linear and quadratic interpolation methods on the sampled field to investigate what is the minimum number of samples required to define the deep ocean total inorganic carbon (TCO2) field within the limits of experimental accuracy (+/- 4 micromol/kg). Within the limits of current measurements, these lines were oversampled in the deep ocean. Should the precision of the measurement be improved, then a denser sampling pattern may be desirable in the future. This approach rationalizes the efficient use of resources for field work and for estimating gridded (TCO2) fields needed to constrain geochemical models.

  17. Correlation of the concentration of the carbon-associated radiation damage levels with the total carbon concentration in silicon

    Energy Technology Data Exchange (ETDEWEB)

    Ferenczi, G.; Londos, C.A.; Pavelka, T.; Somogyi, M.; Mertens, A.

    1988-01-01

    The dominant carbon-related radiation damage center in silicon was studied in detail by deep level transient spectroscopy. Samples with different carbon and oxygen content were implanted with gradually increasing proton fluence. Two energetically closely spaced levels were revealed and tentative identities were assigned. One at E/sub T/+E/sub V/ = 0.344 eV (sigma/sub p/ = 1.1 x 10/sup -16/ cm/sup 2/) is assigned as the C+O/sub i/ complex, and that at E/sub T/+E/sub V/ = 0.370 eV (sigma/sub p/ = 8 x 10/sup -18/ cm/sup 2/) is assigned as the C/sub s/-Si/sub i/-C/sub s/ complex. It was shown that the concentration of these defects is correlated to the total concentration of carbon in the crystal.

  18. Spectrophotometric measurement of calcium carbonate saturation states in seawater.

    Science.gov (United States)

    Easley, Regina A; Patsavas, Mark C; Byrne, Robert H; Liu, Xuewu; Feely, Richard A; Mathis, Jeremy T

    2013-02-05

    Measurements of ocean pH and carbonate ion concentrations in the North Pacific and Arctic Oceans were used to determine calcium carbonate saturation states (Ω(CaCO(3))) from spectrophotometric methods alone. Total carbonate ion concentrations, [CO(3)(2-)](T), were for the first time at sea directly measured using Pb(II) UV absorbance spectra. The basis of the method is given by the following: [formula see text] where (CO(3))β(1) is the PbCO(3)(0) formation constant, e(i) are molar absorptivity ratios, and R = (250)A/(234)A (ratio of absorbances measured at 250 and 234 nm). On the basis of shipboard and laboratory Pb(II) data and complementary carbon-system measurements, the experimental parameters were determined to be (25 °C) the following: [formula see text]. The resulting mean difference between the shipboard spectrophotometric and conventional determinations of [CO(3)(2-)](T) was ±2.03 μmol kg(-1). The shipboard analytical precision of the Pb(II) method was ∼1.71 μmol kg(-1) (2.28%). Spectrophotometric [CO(3)(2-)](T) and pH(T) were then combined to calculate Ω(CaCO(3)). For the case of aragonite, 95% of the spectrophotometric aragonite saturation states (Ω(Aspec)) were within ±0.06 of the conventionally calculated values (Ω(Acalc)) when 0.5 ≤ Ω(A) ≤ 2.0. When Ω(A) > 2.0, 95% of the Ω(Aspec) values were within ±0.18 of Ω(Acalc). Our shipboard experience indicates that spectrophotometric determinations of [CO(3)(2-)](T) and Ω(CaCO(3)) are straightforward, fast, and precise. The method yields high-quality measurements of two important, rapidly changing aspects of ocean chemistry and offers capabilities suitable for long-term automated in situ monitoring.

  19. Total organic carbon, an important tool in a holistic approach to hydrocarbon source fingerprinting

    International Nuclear Information System (INIS)

    Boehm, P.D.; Burns, W.A.; Page, D.S.; Bence, A.E.; Mankiewicz, P.J.; Brown, J.S.; Douglas, G.S.

    2002-01-01

    Total organic carbon (TOC) was used to verify the consistency of source allocation results for the natural petrogenic hydrocarbon background of the northern Gulf of Alaska and Prince William Sound where the Exxon Valdez oil spill occurred in 1998. The samples used in the study were either pre-spill sediments or from the seafloor outside the spill path. It is assumed that the natural petrogenic hydrocarbon background in the area comes from either seep oil residues and shale erosion including erosion from petroleum source rock shales, or from coals including those of the Bering River coalfields. The objective of this study was to use the TOC calculations to discriminate between the two very different sources. TOC can constrain the contributions of specific sources and rule out incorrect source allocations, particularly when inputs are dominated by fossil organic carbon. The benthic sediments used in this study showed excellent agreement between measured TOC and calculated TOC from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. TOC and fingerprint matches confirmed that TOC sources were properly identified. The matches quantify the hydrocarbon contributions of different sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. It was concluded that the natural petrogenic hydrocarbon background in the sediments in the area comes from eroding Tertiary shales and oil seeps along the northern Gulf of Alaska coast. Thermally mature area coals are excluded from being important contributors to the background at Prince William Sound because of their high TOC content. 26 refs., 4 figs

  20. Total organic carbon, an important tool in a holistic approach to hydrocarbon source fingerprinting

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, P.D. [Battelle, Waltham, MA (United States); Burns, W.A. [W.A. Burns Consulting Services, Houston, TX (United States); Page, D.S. [Bowdoin College, Brunswick, ME (United States); Bence, A.E.; Mankiewicz, P.J. [ExxonMobil Upstream Research Co., Houston, TX (United States); Brown, J.S.; Douglas, G.S. [Battelle, Duxbury, MA (United States)

    2002-07-01

    Total organic carbon (TOC) was used to verify the consistency of source allocation results for the natural petrogenic hydrocarbon background of the northern Gulf of Alaska and Prince William Sound where the Exxon Valdez oil spill occurred in 1998. The samples used in the study were either pre-spill sediments or from the seafloor outside the spill path. It is assumed that the natural petrogenic hydrocarbon background in the area comes from either seep oil residues and shale erosion including erosion from petroleum source rock shales, or from coals including those of the Bering River coalfields. The objective of this study was to use the TOC calculations to discriminate between the two very different sources. TOC can constrain the contributions of specific sources and rule out incorrect source allocations, particularly when inputs are dominated by fossil organic carbon. The benthic sediments used in this study showed excellent agreement between measured TOC and calculated TOC from hydrocarbon fingerprint matches of polycyclic aromatic hydrocarbons (PAH) and chemical biomarkers. TOC and fingerprint matches confirmed that TOC sources were properly identified. The matches quantify the hydrocarbon contributions of different sources to the benthic sediments and the degree of hydrocarbon winnowing by waves and currents. It was concluded that the natural petrogenic hydrocarbon background in the sediments in the area comes from eroding Tertiary shales and oil seeps along the northern Gulf of Alaska coast. Thermally mature area coals are excluded from being important contributors to the background at Prince William Sound because of their high TOC content. 26 refs., 4 figs.

  1. Reviews and syntheses: Calculating the global contribution of coralline algae to total carbon burial

    Science.gov (United States)

    van der Heijden, L. H.; Kamenos, N. A.

    2015-11-01

    The ongoing increase in anthropogenic carbon dioxide (CO2) emissions is changing the global marine environment and is causing warming and acidification of the oceans. Reduction of CO2 to a sustainable level is required to avoid further marine change. Many studies investigate the potential of marine carbon sinks (e.g. seagrass) to mitigate anthropogenic emissions, however, information on storage by coralline algae and the beds they create is scant. Calcifying photosynthetic organisms, including coralline algae, can act as a CO2 sink via photosynthesis and CaCO3 dissolution and act as a CO2 source during respiration and CaCO3 production on short-term timescales. Long-term carbon storage potential might come from the accumulation of coralline algae deposits over geological timescales. Here, the carbon storage potential of coralline algae is assessed using meta-analysis of their global organic and inorganic carbon production and the processes involved in this metabolism. Net organic and inorganic production were estimated at 330 g C m-2 yr-1 and 900 g CaCO3 m-2 yr-1 respectively giving global organic/inorganic C production of 0.7/1.8 × 109 t C yr-1. Calcium carbonate production by free-living/crustose coralline algae (CCA) corresponded to a sediment accretion of 70/450 mm kyr-1. Using this potential carbon storage for coralline algae, the global production of free-living algae/CCA was 0.4/1.2 × 109 t C yr-1 suggesting a total potential carbon sink of 1.6 × 109 tonnes per year. Coralline algae therefore have production rates similar to mangroves, salt marshes and seagrasses representing an as yet unquantified but significant carbon store, however, further empirical investigations are needed to determine the dynamics and stability of that store.

  2. Measurement of carbon-14 in hydrological samples

    International Nuclear Information System (INIS)

    Hussain, S.D.

    1991-11-01

    Thermal neutrons produced by cosmic rays or nuclear weapon tests interact with atmospheric nitrogen resulting in the formation of radiocarbon which, after oxidation into carbon dioxide, follows the natural carbon cycle. The partial pressure of carbon dioxide in the soil is several times that in the atmosphere due to plant root respiration and decay of organic matter. Water absorbs biogenic carbon dioxide while percolating through the unsaturated zone. The carbon content of groundwater is mainly in the form of bicarbonate ions. The extraction of carbon from water sample as barium carbonate is carried out in the field. Benzene is synthesised from the carbonate sample. The activity of radiocarbon in the synthesised benzene is determined by using a liquid scintillation analyzer. Details of sampling procedure, benzene synthesis, counter calibration and treatment of sample data have been given. 7 figs. (author)

  3. Application of sodium carbonate prevents sulphur poisoning of catalysts in automated total mercury analysis

    Science.gov (United States)

    McLagan, David S.; Huang, Haiyong; Lei, Ying D.; Wania, Frank; Mitchell, Carl P. J.

    2017-07-01

    Analysis of high sulphur-containing samples for total mercury content using automated thermal decomposition, amalgamation, and atomic absorption spectroscopy instruments (USEPA Method 7473) leads to rapid and costly SO2 poisoning of catalysts. In an effort to overcome this issue, we tested whether the addition of powdered sodium carbonate (Na2CO3) to the catalyst and/or directly on top of sample material increases throughput of sulphur-impregnated (8-15 wt%) activated carbon samples per catalyst tube. Adding 5 g of Na2CO3 to the catalyst alone only marginally increases the functional lifetime of the catalyst (31 ± 4 g of activated carbon analyzed per catalyst tube) in relation to unaltered catalyst of the AMA254 total mercury analyzer (17 ± 4 g of activated carbon). Adding ≈ 0.2 g of Na2CO3 to samples substantially increases (81 ± 17 g of activated carbon) catalyst life over the unaltered catalyst. The greatest improvement is achieved by adding Na2CO3 to both catalyst and samples (200 ± 70 g of activated carbon), which significantly increases catalyst performance over all other treatments and enables an order of magnitude greater sample throughput than the unaltered samples and catalyst. It is likely that Na2CO3 efficiently sequesters SO2, even at high furnace temperatures to produce Na2SO4 and CO2, largely negating the poisonous impact of SO2 on the catalyst material. Increased corrosion of nickel sampling boats resulting from this methodological variation is easily resolved by substituting quartz boats. Overall, this variation enables an efficient and significantly more affordable means of employing automated atomic absorption spectrometry instruments for total mercury analysis of high-sulphur matrices.

  4. Measurement of carbon thermodynamic activity in sodium

    Energy Technology Data Exchange (ETDEWEB)

    Kozlov, F A; Zagorulko, Yu I; Kovalev, Yu P; Alekseev, V V [Institute of Physics and Power Engineering, Obninsk (USSR)

    1980-05-01

    The report presents the brief outline on system of carbon activity detecting system in sodium (SCD), operating on the carbon-permeable membrane, of the methods and the results of testing it under the experimental circulating loop conditions. The results of carbon activity sensor calibration with the use of equilibrium samples of XI8H9, Fe -8Ni, Fe -12Mn materials are listed. The behaviour of carbon activity sensor signals in sodium under various transitional conditions and hydrodynamic perturbation in the circulating loop, containing carbon bearing impurities in the sodium flow and their deposits on the surfaces flushed by sodium, are described. (author)

  5. Association of nitrate, nitrite, and total organic carbon (TOC) in drinking water and gastrointestinal disease.

    Science.gov (United States)

    Khademikia, Samaneh; Rafiee, Zahra; Amin, Mohammad Mehdi; Poursafa, Parinaz; Mansourian, Marjan; Modaberi, Amir

    2013-01-01

    We aimed to investigate the amounts of nitrate, nitrite, and total organic carbon (TOC) in two drinking water sources and their relationship with some gastrointestinal diseases. This cross-sectional study was conducted in 2012 in Iran. Two wells located in residential areas were selected for sampling and measuring the TOC, nitrate (NO3(-)), and nitrite (NO2(-)). This water is used for drinking as well as for industrial and agricultural consumption. Nitrate and nitrite concentrations of water samples were analyzed using DR 5000 spectrophotometer. The information of patients was collected from the records of the main referral hospital of the region for gastrointestinal diseases. In both areas under study, the mean water nitrate and nitrite concentrations were higher in July than in other months. The mean TOC concentrations in areas 1 and 2 were 2.29 ± 0.012 and 2.03 ± 0.309, respectively. Pollutant concentration and gastrointestinal disease did not show any significant relationship (P > 0.05). Although we did not document significant association of nitrite, nitrate, and TOC content of water with gastrointestinal diseases, it should be considered that such health hazards may develop over time, and the quality of water content should be controlled to prevent different diseases.

  6. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    Science.gov (United States)

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  7. Springtime carbon emission episodes at the Gosan background site revealed by total carbon, stable carbon isotopic composition, and thermal characteristics of carbonaceous particles

    Directory of Open Access Journals (Sweden)

    J. Jung

    2011-11-01

    Full Text Available In order to investigate the emission of carbonaceous aerosols at the Gosan background super-site (33.17° N, 126.10° E in East Asia, total suspended particles (TSP were collected during spring of 2007 and 2008 and analyzed for particulate organic carbon, elemental carbon, total carbon (TC, total nitrogen (TN, and stable carbon isotopic composition (δ13C of TC. The stable carbon isotopic composition of TC (δ13CTC was found to be lowest during pollen emission episodes (range: −26.2‰ to −23.5‰, avg. −25.2 ± 0.9‰, approaching those of the airborne pollen (−28.0‰ collected at the Gosan site. Based on a carbon isotope mass balance equation, we found that ~42% of TC in the TSP samples during the pollen episodes was attributed to airborne pollen from Japanese cedar trees planted around tangerine farms in Jeju Island. A negative correlation between the citric acid-carbon/TC ratios and δ13CTC was obtained during the pollen episodes. These results suggest that citric acid emitted from tangerine fruit may be adsorbed on the airborne pollen and then transported to the Gosan site. Thermal evolution patterns of organic carbon during the pollen episodes were characterized by high OC evolution in the OC2 temperature step (450 °C. Since thermal evolution patterns of organic aerosols are highly influenced by their molecular weight, they can be used as additional information on the formation of secondary organic aerosols and the effect of aging of organic aerosols during the long-range atmospheric transport and sources of organic aerosols.

  8. Temporal and spatial distributions of sediment total organic carbon in an estuary river.

    Science.gov (United States)

    Ouyang, Y; Zhang, J E; Ou, L-T

    2006-01-01

    Understanding temporal and spatial distributions of naturally occurring total organic carbon (TOC) in sediments is critical because TOC is an important feature of surface water quality. This study investigated temporal and spatial distributions of sediment TOC and its relationships to sediment contaminants in the Cedar and Ortega Rivers, Florida, USA, using three-dimensional kriging analysis and field measurement. Analysis of field data showed that large temporal changes in sediment TOC concentrations occurred in the rivers, which reflected changes in the characteristics and magnitude of inputs into the rivers during approximately the last 100 yr. The average concentration of TOC in sediments from the Cedar and Ortega Rivers was 12.7% with a maximum of 22.6% and a minimum of 2.3%. In general, more TOC accumulated at the upper 1.0 m of the sediment in the southern part of the Ortega River although the TOC sedimentation varied with locations and depths. In contrast, high concentrations of sediment contaminants, that is, total polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs), were found in sediments from the Cedar River. There was no correlation between TOC and PAHs or PCBs in these river sediments. This finding is in contradiction to some other studies which reported that the sorption of hydrocarbons is highly related to the organic matter content of sediments. This discrepancy occurred because of the differences in TOC and hydrocarbon source input locations. It was found that more TOC loaded into the southern part of the Ortega River, while almost all of the hydrocarbons entered into the Cedar River. This study suggested that the locations of their input sources as well as the land use patterns should also be considered when relating hydrocarbons to sediment TOC.

  9. Effect of sucralfate on total carbon dioxide concentration in horses subjected to a simulated race test.

    Science.gov (United States)

    Caltabilota, T J; Milizio, J G; Malone, S; Kenney, J D; McKeever, K H

    2010-02-01

    The purpose of this study was to test the hypothesis that sucralfate, a gastric ulcer medication, would alter plasma concentrations of total carbon dioxide (tCO2), lactate (LA), sodium (Na+), potassium (K+), chloride (Cl-) and total protein (TP), as well as calculated plasma strong ion difference (SID) and packed cell volume (PCV) in horses subjected to a simulated race test (SRT). Six unfit Standardbred mares (approximately 520 kg, 9-18 years) were used in a randomized crossover design with the investigators blinded to the treatment given. The horses were assigned to either a control (40-50 mL apple sauce administered orally (PO)) or a sucralfate (20 mg/kg bodyweight dissolved in 40-50 mL apple sauce administered PO) group. Each horse completed a series of SRTs during which blood samples were taken via jugular venipuncture at five sampling intervals (prior to receiving treatment, prior to SRT, immediately following exercise, and at 60 and 90 min post-SRT). During the SRTs, each horse ran on a treadmill fixed on a 6% grade for 2 min at a warm-up speed (4 m/s) and then for 2 min at a velocity predetermined to produce VO2max. Each horse then walked at 4 m/s for 2 min to complete the SRT. Plasma tCO2, electrolytes, LA, and blood PCV and TP were analysed at all intervals. No differences (P>0.05) were detected between control and sucralfate for any of the measured variables. There were differences (P<0.05) in tCO2, SID, PCV, TP, LA and electrolyte concentrations relative to sampling time. However, these differences were attributable to the physiological pressures associated with acute exercise and were not an effect of the medication. It was concluded that sucralfate did not alter plasma tCO2 concentration in this study. Copyright (c) 2008 Elsevier Ltd. All rights reserved.

  10. Carbon monoxide measurements at Mace Head, Ireland

    Science.gov (United States)

    Doddridge, Bruce G.; Dickerson, Russell R.; Spain, T. Gerard; Oltmans, Samuel J.; Novelli, Paul C.

    1994-01-01

    The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

  11. Carbon-14 measurements in aquifers with methane

    International Nuclear Information System (INIS)

    Barker, J.F.; Fritz, P.; Brown, R.M.

    1979-01-01

    A survey of various groundwater systems indicates that methane is a common trace constituent and occasionally a major carbon species in groundwaters. Thermocatalytic methane had delta 13 Csub(CH 4 )>-45 per mille and microbially produced or biogenic methane had delta 13 Csub(CH 4 ) 13 C values for the inorganic carbon. Thermocatalytic methane had no apparent effect on the inorganic carbon. Because methanogenesis seriously affects the carbon isotope geochemistry of groundwaters, the correction of raw 14 C ages of affected groundwaters must consider these effects. Conceptual models are developed which adjust the 14 C activity of the groundwater for the effects of methanogenesis and for the dilution of carbon present during infiltration by simple dissolution of rock carbonate. These preliminary models are applied to groundwaters from the Alliston sand aquifer where methanogenesis has affected most samples. In this system, methanogenic bacteria using organic matter present in the aquifer matrix as substrate have added inorganic carbon to the groundwater which has initiated further carbonate rock dissolution. These processes have diluted the inorganic carbon 14 C activity. The adjusted groundwater ages can be explained in terms of the complex hydrogeology of this aquifer, but also indicate that these conceptual models must be more rigorously tested to evaluate their appropriateness. (author)

  12. Mapping and estimating the total living biomass and carbon in low-biomass woodlands using Landsat 8 CDR data

    Directory of Open Access Journals (Sweden)

    Belachew Gizachew

    2016-06-01

    Full Text Available Abstract Background A functional forest carbon measuring, reporting and verification (MRV system to support climate change mitigation policies, such as REDD+, requires estimates of forest biomass carbon, as an input to estimate emissions. A combination of field inventory and remote sensing is expected to provide those data. By linking Landsat 8 and forest inventory data, we (1 developed linear mixed effects models for total living biomass (TLB estimation as a function of spectral variables, (2 developed a 30 m resolution map of the total living carbon (TLC, and (3 estimated the total TLB stock of the study area. Inventory data consisted of tree measurements from 500 plots in 63 clusters in a 15,700 km2 study area, in miombo woodlands of Tanzania. The Landsat 8 data comprised two climate data record images covering the inventory area. Results We found a linear relationship between TLB and Landsat 8 derived spectral variables, and there was no clear evidence of spectral data saturation at higher biomass values. The root-mean-square error of the values predicted by the linear model linking the TLB and the normalized difference vegetation index (NDVI is equal to 44 t/ha (49 % of the mean value. The estimated TLB for the study area was 140 Mt, with a mean TLB density of 81 t/ha, and a 95 % confidence interval of 74–88 t/ha. We mapped the distribution of TLC of the study area using the TLB model, where TLC was estimated at 47 % of TLB. Conclusion The low biomass in the miombo woodlands, and the absence of a spectral data saturation problem suggested that Landsat 8 derived NDVI is suitable auxiliary information for carbon monitoring in the context of REDD+, for low-biomass, open-canopy woodlands.

  13. Measurement of carbon activity in sodium and steel and the behaviour of carbon-bearing species

    International Nuclear Information System (INIS)

    Rajendran Pillai, S.; Ranganathan, R.; Mathews, C.K.

    1988-01-01

    Carburization or decarburization of structural materials in a sodium system depends on the local differences in carbon activity. The behaviour of carbon-bearing species in sodium influences its carbon activity. In order to understand the behaviour of carbon in these systems, an electrochemical carbon meter was fabricated in our laboratory. The original version of this meter was capable of operating in the temperature range of 850-980 K. Studies are carried out to extend this lower limit of temperature. Employing the carbon meter, experiments were carried out to understand the behaviour of carbon-bearing species. Gas equilibration experiments were also carried out with the same view. A new method for measuring the carbon activity in steels are described which employs the carbon meter. A review on these investigations and the conclusions reached on the behaviour of carbon in fast reactor loops are described

  14. Photosynthetic light reactions increase total lipid accumulation in carbon-supplemented batch cultures of Chlorella vulgaris.

    Science.gov (United States)

    Woodworth, Benjamin D; Mead, Rebecca L; Nichols, Courtney N; Kolling, Derrick R J

    2015-03-01

    Microalgae are an attractive biofuel feedstock because of their high lipid to biomass ratios, lipid compositions that are suitable for biodiesel production, and the ability to grow on varied carbon sources. While algae can grow autotrophically, supplying an exogenous carbon source can increase growth rates and allow heterotrophic growth in the absence of light. Time course analyses of dextrose-supplemented Chlorella vulgaris batch cultures demonstrate that light availability directly influences growth rate, chlorophyll production, and total lipid accumulation. Parallel photomixotrophic and heterotrophic cultures grown to stationary phase reached the same amount of biomass, but total lipid content was higher for algae grown in the presence of light (an average of 1.90 mg/mL vs. 0.77 mg/mL over 5 days of stationary phase growth). Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Watershed scale spatial variability in dissolved and total organic and inorganic carbon in contrasting UK catchments

    Science.gov (United States)

    Cumberland, S.; Baker, A.; Hudson, N. J.

    2006-12-01

    investigations into carbon fluxes in British rivers have focused on long term increases in DOC in rural and predominantly upland catchments. Our results suggest that research is needed into understanding long term variations in inorganic carbon concentration, as well as total (organic and inorganic) carbon fluxes from British rivers, to obtain total carbon loads. In particular, we provide evidence that DIC concentrations may be greater in urbanized catchments compared to equivalent non-urban catchments, with the implication that increasing urbanization in the future will see increases in riverine DIC and a decrease in the strength of any DOC DIC anti correlation. Further studies of urban catchment DIC sources, within stream processing, long term trends, and potential ecological impacts, are required.

  16. Assessing Educational Processes Using Total-Quality-Management Measurement Tools.

    Science.gov (United States)

    Macchia, Peter, Jr.

    1993-01-01

    Discussion of the use of Total Quality Management (TQM) assessment tools in educational settings highlights and gives examples of fishbone diagrams, or cause and effect charts; Pareto diagrams; control charts; histograms and check sheets; scatter diagrams; and flowcharts. Variation and quality are discussed in terms of continuous process…

  17. Total error vs. measurement uncertainty: revolution or evolution?

    Science.gov (United States)

    Oosterhuis, Wytze P; Theodorsson, Elvar

    2016-02-01

    The first strategic EFLM conference "Defining analytical performance goals, 15 years after the Stockholm Conference" was held in the autumn of 2014 in Milan. It maintained the Stockholm 1999 hierarchy of performance goals but rearranged them and established five task and finish groups to work on topics related to analytical performance goals including one on the "total error" theory. Jim Westgard recently wrote a comprehensive overview of performance goals and of the total error theory critical of the results and intentions of the Milan 2014 conference. The "total error" theory originated by Jim Westgard and co-workers has a dominating influence on the theory and practice of clinical chemistry but is not accepted in other fields of metrology. The generally accepted uncertainty theory, however, suffers from complex mathematics and conceived impracticability in clinical chemistry. The pros and cons of the total error theory need to be debated, making way for methods that can incorporate all relevant causes of uncertainty when making medical diagnoses and monitoring treatment effects. This development should preferably proceed not as a revolution but as an evolution.

  18. A comparison of new measurements of total monoterpene flux with improved measurements of speciated monoterpene flux

    Directory of Open Access Journals (Sweden)

    A. Lee

    2005-01-01

    Full Text Available Many monoterpenes have been identified in forest emissions using gas chromatography (GC. Until now, it has been impossible to determine whether all monoterpenes are appropriately measured using GC techniques. We used a proton transfer reaction mass spectrometer (PTR-MS coupled with the eddy covariance (EC technique to measure mixing ratios and fluxes of total monoterpenes above a ponderosa pine plantation. We compared PTR-MS-EC results with simultaneous measurements of eight speciated monoterpenes, β-pinene, α-pinene, 3-carene, d-limonene, β-phellandrene, α-terpinene, camphene, and terpinolene, made with an automated, in situ gas chromatograph with flame ionization detectors (GC-FID, coupled to a relaxed eddy accumulation system (REA. Monoterpene mixing ratios and fluxes measured by PTR-MS averaged 30±2.3% and 31±9.2% larger than by GC-FID, with larger mixing ratio discrepancies between the two techniques at night than during the day. Two unidentified peaks that correlated with β-pinene were resolved in the chromatograms and completely accounted for the daytime difference and reduced the nighttime mixing ratio difference to 20±2.9%. Measurements of total monoterpenes by PTR-MS-EC indicated that GC-FID-REA measured the common, longer-lived monoterpenes well, but that additional terpenes were emitted from the ecosystem that represented an important contribution to the total mixing ratio above the forest at night.

  19. Measurement of the neutron total cross section of sodium

    International Nuclear Information System (INIS)

    Larson, D.C.; Harvey, J.A.; Hill, M.W.

    1976-01-01

    The transmission of neutrons through a sample of pure sodium was measured in the energy range 40 keV to 20 MeV. The measurement points out several areas for improvement in the sodium evaluation for ENDF/B-V, the most important being the broadening of the minimum at 300 keV

  20. Measuring Carbon Footprint of Flexible Pavement Construction Project in Indonesia

    Science.gov (United States)

    Hatmoko, Jati Utomo Dwi; Hidayat, Arif; Setiawati, Apsari; Prasetyo, Stefanus Catur Adi

    2018-02-01

    Road infrastructure in Indonesia is mainly dominated by flexible pavement type. Its construction process, however, has raised concerns in terms of its environment impacts. This study aims to track and measure the carbon footprint of flexible pavement. The objectives are to map the construction process in relation to greenhouse gas (GHG) emissions, to quantify them in terms of carbon dioxide equivalents (CO2e) as generated by the process of production and transportation of raw materials, and the operation of plant off-site and on-site project. Data collection was done by having site observations and interviews with project stakeholders. The results show a total emissions of 70.888 tonnes CO2e, consisting of 34.248 tonnes CO2e (48.31%) off-site activities and 36.640 tonnes CO2e (51.687%) on-site activities. The two highest CO2e emissions were generated by the use of plant for asphalt concrete laying activities accounted 34.827 tonnes CO2e (49.130%), and material transportation accounted 24.921 (35.155%). These findings provide a new perspective of the carbon footprint in flexible pavement and suggest the urgent need for the use of more efficient and environmentally friendly plant in construction process as it shows the most significant contribution on the CO2e. This study provides valuable understanding on the environmental impact of typical flexible pavement projects in Indonesia, and further can be used for developing green road framework.

  1. Centennial-scale records of total organic carbon in sediment cores from the South Yellow Sea, China

    Science.gov (United States)

    Zhu, Qing; Lin, Jia; Hong, Yuehui; Yuan, Lirong; Liu, Jinzhong; Xu, Xiaoming; Wang, Jianghai

    2018-01-01

    Global carbon cycling is a significant factor that controls climate change. The centennial-scale variations in total organic carbon (TOC) contents and its sources in marginal sea sediments may reflect the influence of human activities on global climate change. In this study, two fine-grained sediment cores from the Yellow Sea Cold Water Mass of the South Yellow Sea were used to systematically determine TOC contents and stable carbon isotope ratios. These results were combined with previous data of black carbon and 210Pb dating from which we reconstructed the centennial-scale initial sequences of TOC, terrigenous TOC (TOCter) and marine autogenous TOC (TOCmar) after selecting suitable models to correct the measured TOC (TOCcor). These sequences showed that the TOCter decreased with time in the both cores while the TOCmar increased, particularly the rapid growth in core H43 since the late 1960s. According to the correlation between the Huanghe (Yellow) River discharge and the TOCcor, TOCter, or TOCmar, we found that the TOCter in the two cores mainly derived from the Huanghe River and was transported by it, and that higher Huanghe River discharge could strengthen the decomposition of TOCmar. The newly obtained initial TOC sequences provide important insights into the interaction between human activities and natural processes.

  2. Measurement of total dissolved solids using electrical conductivity

    International Nuclear Information System (INIS)

    Ray, Vinod K.; Jat, J.R.; Reddy, G.B.; Balaji Rao, Y.; Phani Babu, C.; Kalyanakrishnan, G.

    2017-01-01

    Total dissolved solids (TDS) is an important parameter for the disposal of effluents generated during processing of different raw materials like Magnesium Di-uranate (MDU), Heat Treated Uranium Peroxide (HTUP), Sodium Di-uranate (SDU) in Uranium Extraction plant and Washed and Dried Frit (WDF) in Zirconium Extraction Plant. The present paper describes the use of electrical conductivity for determination of TDS. As electrical conductivity is matrix dependent property, matrix matched standards were prepared for determination of TDS in ammonium nitrate solution (AN) and mixture of ammonium nitrate and ammonium sulphate (AN/AS) and results were found to be in good agreement when compared with evaporation method. (author)

  3. Measuring thin films using quantitative frustrated total internal reflection (FTIR)

    NARCIS (Netherlands)

    Shirota, Minori; van Limbeek, Michiel A.J.; Lohse, Detlef; Sun, Chao

    2017-01-01

    Abstract.: In the study of interactions between liquids and solids, an accurate measurement of the film thickness between the two media is essential to study the dynamics. As interferometry is restricted by the wavelength of the light source used, recent studies of thinner films have prompted the

  4. Measuring total economic benefits from water in plantation forestry ...

    African Journals Online (AJOL)

    A quasi input-output framework was applied to measuring direct and indirect economic benefits from water use in plantation forestry in the Crocodile river catchment of South Africa. The study accounted for indirect economic benefits generated in downstream timber processing activities and input supply sectors linked with ...

  5. Optimization of supercritical carbon dioxide extraction of Piper Betel Linn leaves oil and total phenolic content

    Science.gov (United States)

    Aziz, A. H. A.; Yunus, M. A. C.; Arsad, N. H.; Lee, N. Y.; Idham, Z.; Razak, A. Q. A.

    2016-11-01

    Supercritical Carbon Dioxide (SC-CO2) Extraction was applied to extract piper betel linn leaves. The piper betel leaves oil was used antioxidant, anti-diabetic, anticancer and antistroke. The aim of this study was to optimize the conditions of pressure, temperature and flowrate for oil yield and total phenolic content. The operational conditions of SC-CO2 studied were pressure (10, 20, 30 MPa), temperature (40, 60, 80 °C) and flowrate carbon dioxide (4, 6, 8 mL/min). The constant parameters were average particle size and extraction regime, 355pm and 3.5 hours respectively. First order polynomial expression was used to express the extracted oil while second order polynomial expression was used to express the total phenolic content and the both results were satisfactory. The best conditions to maximize the total extraction oil yields and total phenolic content were 30 MPa, 80 °C and 4.42 mL/min leading to 7.32% of oil and 29.72 MPa, 67.53 °C and 7.98 mL/min leading to 845.085 mg GAE/g sample. In terms of optimum condition with high extraction yield and high total phenolic content in the extracts, the best operating conditions were 30 MPa, 78 °C and 8 mL/min with 7.05% yield and 791.709 mg gallic acid equivalent (GAE)/g sample. The most dominant condition for extraction of oil yield and phenolic content were pressure and CO2 flowrate. The results show a good fit to the proposed model and the optimal conditions obtained were within the experimental range with the value of R2 was 96.13% for percentage yield and 98.52% for total phenolic content.

  6. Anthropogenic Influence on Secondary Aerosol Formation and Total Water-Soluble Carbon on Atmospheric Particles

    Science.gov (United States)

    Gioda, Adriana; Mateus, Vinicius; Monteiro, Isabela; Taira, Fabio; Esteves, Veronica; Saint'Pierre, Tatiana

    2013-04-01

    On a global scale, the atmosphere is an important source of nutrients, as well as pollutants, because of its interfaces with soil and water. Important compounds in the gaseous phase are in both organic and inorganic forms, such as organic acids, nitrogen, sulfur and chloride. In spite of the species in gas form, a huge number of process, anthropogenic and natural, are able to form aerosols, which may be transported over long distances. Sulfates e nitrates are responsible for rain acidity; they may also increase the solubility of organic compounds and metals making them more bioavailable, and also can act as cloud condensation nuclei (CCN). Aerosol samples (PM2.5) were collected in a rural and industrial area in Rio de Janeiro, Brazil, in order to quantify chemical species and evaluate anthropogenic influences in secondary aerosol formation and organic compounds. Samples were collected during 24 h every six days using a high-volume sampler from August 2010 to July 2011. The aerosol mass was determined by Gravimetry. The water-soluble ionic composition (WSIC) was obtained by Ion Chromatography in order to determine the major anions (NO3-, SO4= and Cl-); total water-soluble carbon (TWSC) was determined by a TOC analyzer. The average aerosol (PM2.5) concentrations ranged from 1 to 43 ug/m3 in the industrial site and from 4 to 35 ug/m3 in the rural area. Regarding anions, the highest concentrations were measured for SO42- (10.6 μg/m3-12.6 μg/m3); where the lowest value was found in the rural site and the highest in the industrial. The concentrations for NO3- and Cl- ranged from 4.2 μg/m3 to 9.3 μg/m3 and 3.1 μg/m3 to 6.4 μg /m3, respectively. Sulfate was the major species and, like nitrate, it is related to photooxidation in the atmosphere. Interestingly sulfate concentrations were higher during the dry period and could be related to photochemistry activity. The correlations between nitrate and non-sea-salt sulfate were weak, suggesting different sources for these

  7. A new fully automated FTIR system for total column measurements of greenhouse gases

    Directory of Open Access Journals (Sweden)

    M. C. Geibel

    2010-10-01

    Full Text Available This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON. It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics.

    Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control.

    First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months.

    After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  8. A new fully automated FTIR system for total column measurements of greenhouse gases

    Science.gov (United States)

    Geibel, M. C.; Gerbig, C.; Feist, D. G.

    2010-10-01

    This article introduces a new fully automated FTIR system that is part of the Total Carbon Column Observing Network (TCCON). It will provide continuous ground-based measurements of column-averaged volume mixing ratio for CO2, CH4 and several other greenhouse gases in the tropics. Housed in a 20-foot shipping container it was developed as a transportable system that could be deployed almost anywhere in the world. We describe the automation concept which relies on three autonomous subsystems and their interaction. Crucial components like a sturdy and reliable solar tracker dome are described in detail. The automation software employs a new approach relying on multiple processes, database logging and web-based remote control. First results of total column measurements at Jena, Germany show that the instrument works well and can provide parts of the diurnal as well as seasonal cycle for CO2. Instrument line shape measurements with an HCl cell suggest that the instrument stays well-aligned over several months. After a short test campaign for side by side intercomaprison with an existing TCCON instrument in Australia, the system will be transported to its final destination Ascension Island.

  9. A Total Management Measurement Model for the Naval Weapons Center

    Science.gov (United States)

    1991-02-01

    Efficiency Productivity Public safety Employee safety Safety’Sccurity Customer safety Product security _ Quality of worklife Corporate Concern for...3 Corporate-ievel measures should represent a balance of in-house expertise; types of customers; and issues that surpass the customers’ I expertise...consideration. Examining the balance of distribution of these resources is also important. Addressing these issues would link the best potential to the most

  10. Whole-body dose meters. Measurements of total activity

    International Nuclear Information System (INIS)

    Koeppe, P.; Klinikum Steglitz, Berlin

    1990-01-01

    By means of measurements using a whole-body dose meter, the course of the incorporation of radionuclides was established between April 1986 and May 1989 for unchanged conditions of alimentation, activity-conscious alimentation, and uniquely increased incorporation. Monitoring covered persons from the most different spheres of life. The incorporation is compared with the one resulting from nuclear weapons explosions in the atmosphere. (DG) [de

  11. Measuring performance improvement: total organizational commitment or clinical specialization.

    Science.gov (United States)

    Caron, Aleece; Jones, Paul; Neuhauser, Duncan; Aron, David C

    2004-01-01

    Resources for hospitals are limited when they are faced with multiple publicly reported performance measures as tools to assess quality. The leadership in these organizations may choose to focus on 1 or 2 of these outcomes. An alternative approach is that the leadership may commit resources or create conditions that result in improved quality over a broad range of measures. We used aggregated data on mortality, length of stay, and obstetrical outcomes from Greater Cleveland Health Quality Choice data to test these theories. We used Pearson correlation analysis to determine of outcomes were correlated with one another. We used repeated-measures ANOVA to determine if an association existed between outcome and time and outcome and hospital. All of the outcomes across all hospitals demonstrate a trend of overall improvement. Both the Pearson and ANOVA result support the hypothesis for the organization-wide approach to quality improvement. Hospital that make improvements in one clinical area trend to make improvements in others. Hospitals that produce improvements in limited clinical or administrative areas may not have completely adopted CQI into their culture or may not have yet realized the benefits of their organizational commitments, but use some of the concepts to improve quality outcomes.

  12. Measurements of total dissolved inorganic carbon (DIC), total alkalinity (TA) and pH (on total scale) and other variables collected from surface underway observations using Dissolved Inorganic Carbon Extractor (DICE), Metrohm 876 Dosimat Plus, Agilent 8453 spectrometer and other instruments from R/V Roger Revelle in the Indian Ocean during the transit time on GO-SHIP sections I08S and I09N (EXPOCODEs 33RR20160208 and 33RR20160321) from 2016-02-08 to 2016-03-24 (NCEI Accession 0162262)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Global Ocean Ship-based Hydrographic Investigations Program (GO-SHIP) brings together scientists with interests in physical oceanography, the carbon cycle,...

  13. Drought sensitivity of Amazonian carbon balance revealed by atmospheric measurements

    Science.gov (United States)

    Gatti, L. V.; Gloor, M.; Miller, J. B.; Doughty, C. E.; Malhi, Y.; Domingues, L. G.; Basso, L. S.; Martinewski, A.; Correia, C. S. C.; Borges, V. F.; Freitas, S.; Braz, R.; Anderson, L. O.; Rocha, H.; Grace, J.; Phillips, O. L.; Lloyd, J.

    2014-02-01

    Feedbacks between land carbon pools and climate provide one of the largest sources of uncertainty in our predictions of global climate. Estimates of the sensitivity of the terrestrial carbon budget to climate anomalies in the tropics and the identification of the mechanisms responsible for feedback effects remain uncertain. The Amazon basin stores a vast amount of carbon, and has experienced increasingly higher temperatures and more frequent floods and droughts over the past two decades. Here we report seasonal and annual carbon balances across the Amazon basin, based on carbon dioxide and carbon monoxide measurements for the anomalously dry and wet years 2010 and 2011, respectively. We find that the Amazon basin lost 0.48+/-0.18 petagrams of carbon per year (PgCyr-1) during the dry year but was carbon neutral (0.06+/-0.1PgCyr-1) during the wet year. Taking into account carbon losses from fire by using carbon monoxide measurements, we derived the basin net biome exchange (that is, the carbon flux between the non-burned forest and the atmosphere) revealing that during the dry year, vegetation was carbon neutral. During the wet year, vegetation was a net carbon sink of 0.25+/-0.14PgCyr-1, which is roughly consistent with the mean long-term intact-forest biomass sink of 0.39+/-0.10PgCyr-1 previously estimated from forest censuses. Observations from Amazonian forest plots suggest the suppression of photosynthesis during drought as the primary cause for the 2010 sink neutralization. Overall, our results suggest that moisture has an important role in determining the Amazonian carbon balance. If the recent trend of increasing precipitation extremes persists, the Amazon may become an increasing carbon source as a result of both emissions from fires and the suppression of net biome exchange by drought.

  14. Leaching behavior of total organic carbon, nitrogen, and phosphorus from banana peel.

    Science.gov (United States)

    Jiang, Ruixue; Sun, Shujuan; Xu, Yan; Qiu, Xiudong; Yang, Jili; Li, Xiaochen

    2015-01-01

    The leaching behavior of organic carbon and nutrient compounds from banana peel (BP) was investigated in batch assays with respect to particle size, contact time, pH value, and temperature. The granularity, contact time, pH, and temperature caused no significant effects on the leaching of total phosphorus (TP) from the BP. The maximum leached total nitrogen (TN) content was found at pH 5.0 and 90 minutes, while no significant effects were caused by the granularity and temperature. The maximum leached total organic carbon (TOC) content was found by using a powder of 40 mesh, 150 minutes and at pH 6.0, while the temperature had no effect on the TOC leaching. The proportions of the TN, TP, and TOC contents leached from the dried BP ranged from 33.6% to 40.9%, 60.4% to 72.7%, and 8.2% to 9.9%, respectively, indicating that BP could be a potential pollution source for surface and ground water if discharged as domestic waste or reutilized without pretreatment.

  15. Measurement of carbon activity of sodium using nickel tabs and the Harwell Carbon Meter - Preliminary experience

    International Nuclear Information System (INIS)

    Blundell, A.; Thorley, A.W.

    1980-01-01

    Carbon can have an important effect on the mechanical properties of certain constructional materials likely to be used in the LMFBRs. Transfer of carbon will occur between the metal and the sodium at any particular location to bring the chemical potential of carbon in both components to the sam: value. Thus, in a mixed system containing austenitic stainless steel and unstabilized ferritic steel, carbon could be transferred by the sodium from the high carbon activity ferritic to the lower activity austenitic steel. Loss of carbon from the unstabilized ferritic steel leads to a weaker, more ductile material, while carburization of the stainless steel could lead to its embrittlement. Similarly carbon entering the coolant in the form of oil from leaking mechanical pumps could have similar effects on the mechanical property of stainless steels. In the light of these possibilities it is essential to measure the carbon activity of the sodium so that its effect on materials properties can be predicted

  16. Measurement of carbon activity of sodium using nickel tabs and the Harwell Carbon Meter - Preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Blundell, A; Thorley, A W [UKAEA, Risley, Warrington, Cheshire (United Kingdom)

    1980-05-01

    Carbon can have an important effect on the mechanical properties of certain constructional materials likely to be used in the LMFBRs. Transfer of carbon will occur between the metal and the sodium at any particular location to bring the chemical potential of carbon in both components to the sam: value. Thus, in a mixed system containing austenitic stainless steel and unstabilized ferritic steel, carbon could be transferred by the sodium from the high carbon activity ferritic to the lower activity austenitic steel. Loss of carbon from the unstabilized ferritic steel leads to a weaker, more ductile material, while carburization of the stainless steel could lead to its embrittlement. Similarly carbon entering the coolant in the form of oil from leaking mechanical pumps could have similar effects on the mechanical property of stainless steels. In the light of these possibilities it is essential to measure the carbon activity of the sodium so that its effect on materials properties can be predicted.

  17. Is black carbon a better predictor of polycyclic aromatic hydrocarbon distribution in soils than total organic carbon?

    International Nuclear Information System (INIS)

    Agarwal, Tripti; Bucheli, Thomas D.

    2011-01-01

    Black carbon (BC) and total organic carbon (TOC) were quantified in the surface soils of Switzerland (N = 105) and Delhi (N = 36), India, to examine their relationships with contents of polycyclic aromatic hydrocarbons (PAH). BC content in Swiss (background) soils (N = 104) varied from 0.41 to 4.75 mg/g (median: 1.13 mg/g) and constituted 1-9% (median: 3%) of TOC. Indian (urban) soils had similar BC concentrations (0.37-2.05 mg/g, median: 1.19 mg/g), with relatively higher BC/TOC (6-23%, median: 13%). Similar to TOC, BC showed significant positive correlation with lighter PAH, but no correlation with heavier PAH in Swiss soils. In contrast, heavier PAH were significantly correlated only with BC in Delhi soils. It seems that TOC governs the distribution of PAH in organic matter rich background soils, while the proximity to emission sources is reflected by BC-PAH association in urban soils. - Light PAH correlated with TOC in background soils, whereas heavy PAH were associated with BC close to emission sources.

  18. Enhancement of total lipid yield by nitrogen, carbon, and iron supplementation in isolated microalgae.

    Science.gov (United States)

    Sivaramakrishnan, Ramachandran; Incharoensakdi, Aran

    2017-08-01

    The biochemical contents and biodiesel production ability of three microalgal strains grown under different sodium nitrate, sodium carbonate, and ferric ammonium citrate (iron) levels were investigated. The highest biomass and lipid contents were found in Scenedesmus sp., Chlorella sp., and Chlamydomonas sp. when grown in normal BG-11 containing sodium carbonate concentration at 0.03 g · L -1 , and in normal BG-11 containing iron concentration (IC) at 0.009 or 0.012 g · L -1 . Increasing the sodium nitrate level increased the biomass content, but decreased the lipid content in all three microalgae. Among the three microalgae, Scenedesmus sp. showed the highest total lipid yield of 0.69 g · L -1 under the IC of 0.012 g · L -1 . Palmitic and oleic acids were the major fatty acids of Scenedesmus sp. and Chlamydomonas sp. lipids. On the other hand, Chlorella sp. lipids were rich in palmitic, oleic, and linolenic acids, and henceforth contributing to poor biodiesel properties below the standard limits. The three isolated strains had a potential for biodiesel production. Nevertheless, Scenedesmus sp. from stone quarry pond water was the most suitable source for biodiesel production with tolerance toward the high concentration of sodium carbonate without the loss of its biodiesel properties. © 2017 Phycological Society of America.

  19. Maximum total organic carbon limits at different DWPF melter feed maters (U)

    International Nuclear Information System (INIS)

    Choi, A.S.

    1996-01-01

    The document presents information on the maximum total organic carbon (TOC) limits that are allowable in the DWPF melter feed without forming a potentially flammable vapor in the off-gas system were determined at feed rates varying from 0.7 to 1.5 GPM. At the maximum TOC levels predicted, the peak concentration of combustible gases in the quenched off-gas will not exceed 60 percent of the lower flammable limit during a 3X off-gas surge, provided that the indicated melter vapor space temperature and the total air supply to the melter are maintained. All the necessary calculations for this study were made using the 4-stage cold cap model and the melter off-gas dynamics model. A high-degree of conservatism was included in the calculational bases and assumptions. As a result, the proposed correlations are believed to by conservative enough to be used for the melter off-gas flammability control purposes

  20. Solid State Sensor for Simultaneous Measurement of Total Alkalinity and pH of Seawater.

    Science.gov (United States)

    Briggs, Ellen M; Sandoval, Sergio; Erten, Ahmet; Takeshita, Yuichiro; Kummel, Andrew C; Martz, Todd R

    2017-09-22

    A novel design is demonstrated for a solid state, reagent-less sensor capable of rapid and simultaneous measurement of pH and Total Alkalinity (A T ) using ion sensitive field effect transistor (ISFET) technology to provide a simplified means of characterization of the aqueous carbon dioxide system through measurement of two "master variables": pH and A T . ISFET-based pH sensors that achieve 0.001 precision are widely used in various oceanographic applications. A modified ISFET is demonstrated to perform a nanoliter-scale acid-base titration of A T in under 40 s. This method of measuring A T , a Coulometric Diffusion Titration, involves electrolytic generation of titrant, H + , through the electrolysis of water on the surface of the chip via a microfabricated electrode eliminating the requirement of external reagents. Characterization has been performed in seawater as well as titrating individual components (i.e., OH - , HCO 3 - , CO 3 2- , B(OH) 4 - , PO 4 3- ) of seawater A T . The seawater measurements are consistent with the design in reaching the benchmark goal of 0.5% precision in A T over the range of seawater A T of ∼2200-2500 μmol kg -1 which demonstrates great potential for autonomous sensing.

  1. Total carbon content and humic substances quality in selected subtypes of Cambisols

    Directory of Open Access Journals (Sweden)

    Veronika Petrášová

    2009-01-01

    Full Text Available Cambisols cover an estimated 45% of agricultural soils in the Czech Republic. We aimed our work at stabile forms of organic carbon and humic substances quality in Cambisols under different types of soil management (grassland and arable soil. Object of our study were the following subtypes of Cambisols: Eutric Cambisol (locality Vatín – arable soil, Eutric Cambisol (locality Vatín – grassland, Haplic Cambisol (locality Náměšť n/Oslavou – arable soil, Leptic Cambisol (locality Ocmanice – grassland, Haplic Cambisol (locality Nové Město na Moravě – arable soil, Haplic Cambisol (locality Přemyslov – Tři Kameny – grassland, Arenic Cambisol (locality Pocoucov – arable soil, Dystric Cambisol (locality Sněžné – arable soil, Dystric Cambisol (locality Velká Skrovnice – arable soil, Dystric Cambisol (locality Vojnův Městec – arable soil. Non-destructive spectroscopic methods such as UV-VIS spectroscopy, synchronous fluorescence spectroscopy (SFS and 13C NMR spectroscopy for humic substances (HS quality assessment were used. Total organic carbon (TOC content was determined by oxidimetric titration. Fractionation of HS was made by short fractionation method. Isolation of pure humic ­acids (HA preparation was made according to the standard IHSS method.Results showed that TOC and humus content varied from 2.70 % (grassland to 1.3 % (arable soil. Ave­ra­ge HS sum was 8.4 mg / kg in grassland and 6.4 mg / kg in arable soil. Average HA sum was 3.6 mg / kg in grassland and 3 mg / kg in arable soil. Fulvic acids (FA content was 4.7 mg / kg in grassland and 3.7 mg / kg in arable soil. HS quality was low and very similar for all studied samples. HA/FA ratio low (< 1. HS absorbance in UV-VIS spectral range was low and similar in all studied samples. Higher absorption in this spectral range was closely connected with higher HS content. Also in 2D-synchronous fluorescence scan spectra

  2. Total mercury, methyl mercury, and carbon in fresh and burned plants and soil in Northwestern Ontario

    International Nuclear Information System (INIS)

    Mailman, M.; Bodaly, R.A.

    2005-01-01

    Terrestrial plants and soil contain substantial amounts of organic carbon (C) and mercury. Flooding terrestrial areas stimulates microbial methyl mercury (MeHg) production and fish obtain elevated MeHg concentrations. Our purpose was to determine the loss of C, total mercury (THg), and MeHg from boreal plants and soil after burning to assess the potential of burning before flooding to lower MeHg. Fresh plants contained 4 to 52 ng g -1 dry weight (dw) of THg and 0.1 to 1.3 ng g -1 dw of MeHg. Upland soils contained 162±132 ng g -1 dw of THg and 0.6±0.6 ng g -1 dw of MeHg. Complete burning caused plants to lose 96, 98, 97, and 94% of the mass, C, THg, and MeHg, respectively. Upland soil lost 27, 95, 79, and 82% of the mass, C, THg, and MeHg, respectively. Our results demonstrated that a substantial loss of C, THg, and MeHg was caused by burning. - Burning terrestrial vegetation and soil causes substantial losses of organic carbon, total mercury, and methyl mercury

  3. Total mercury, methyl mercury, and carbon in fresh and burned plants and soil in Northwestern Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Mailman, M. [Department of Zoology, University of Manitoba, Winnipeg, Man. R3T 2N2 (Canada); Freshwater Institute, 501 University Crescent, Winnipeg, Man. R3T 2N6 (Canada)]. E-mail: mailmanma@dfo-mpo.gc.ca; Bodaly, R.A. [Department of Zoology, University of Manitoba, Winnipeg, Man. R3T 2N2 (Canada); Freshwater Institute, 501 University Crescent, Winnipeg, Man. R3T 2N6 (Canada)

    2005-11-15

    Terrestrial plants and soil contain substantial amounts of organic carbon (C) and mercury. Flooding terrestrial areas stimulates microbial methyl mercury (MeHg) production and fish obtain elevated MeHg concentrations. Our purpose was to determine the loss of C, total mercury (THg), and MeHg from boreal plants and soil after burning to assess the potential of burning before flooding to lower MeHg. Fresh plants contained 4 to 52 ng g{sup -1} dry weight (dw) of THg and 0.1 to 1.3 ng g{sup -1} dw of MeHg. Upland soils contained 162{+-}132 ng g{sup -1} dw of THg and 0.6{+-}0.6 ng g{sup -1} dw of MeHg. Complete burning caused plants to lose 96, 98, 97, and 94% of the mass, C, THg, and MeHg, respectively. Upland soil lost 27, 95, 79, and 82% of the mass, C, THg, and MeHg, respectively. Our results demonstrated that a substantial loss of C, THg, and MeHg was caused by burning. - Burning terrestrial vegetation and soil causes substantial losses of organic carbon, total mercury, and methyl mercury.

  4. Soil Organic Carbon Fractions and Stocks Respond to Restoration Measures in Degraded Lands by Water Erosion.

    Science.gov (United States)

    Nie, Xiaodong; Li, Zhongwu; Huang, Jinquan; Huang, Bin; Xiao, Haibing; Zeng, Guangming

    2017-05-01

    Assessing the degree to which degraded soils can be recovered is essential for evaluating the effects of adopted restoration measures. The objective of this study was to determine the restoration of soil organic carbon under the impact of terracing and reforestation. A small watershed with four typical restored plots (terracing and reforestation (four different local plants)) and two reference plots (slope land with natural forest (carbon-depleted) and abandoned depositional land (carbon-enriched)) in subtropical China was studied. The results showed that soil organic carbon, dissolved organic carbon and microbial biomass carbon concentrations in the surface soil (10 cm) of restored lands were close to that in abandoned depositional land and higher than that in natural forest land. There was no significant difference in soil organic carbon content among different topographic positions of the restored lands. Furthermore, the soil organic carbon stocks in the upper 60 cm soils of restored lands, which were varied between 50.08 and 62.21 Mg C ha -1 , were higher than 45.90 Mg C ha -1 in natural forest land. Our results indicated that the terracing and reforestation could greatly increase carbon sequestration and accumulation and decrease carbon loss induced by water erosion. And the combination measures can accelerate the restoration of degraded soils when compared to natural forest only. Forest species almost have no impact on the total amount of soil organic carbon during restoration processes, but can significantly influence the activity and stability of soil organic carbon. Combination measures which can provide suitable topography and continuous soil organic carbon supply could be considered in treating degraded soils caused by water erosion.

  5. Soil Organic Carbon Fractions and Stocks Respond to Restoration Measures in Degraded Lands by Water Erosion

    Science.gov (United States)

    Nie, Xiaodong; Li, Zhongwu; Huang, Jinquan; Huang, Bin; Xiao, Haibing; Zeng, Guangming

    2017-05-01

    Assessing the degree to which degraded soils can be recovered is essential for evaluating the effects of adopted restoration measures. The objective of this study was to determine the restoration of soil organic carbon under the impact of terracing and reforestation. A small watershed with four typical restored plots (terracing and reforestation (four different local plants)) and two reference plots (slope land with natural forest (carbon-depleted) and abandoned depositional land (carbon-enriched)) in subtropical China was studied. The results showed that soil organic carbon, dissolved organic carbon and microbial biomass carbon concentrations in the surface soil (10 cm) of restored lands were close to that in abandoned depositional land and higher than that in natural forest land. There was no significant difference in soil organic carbon content among different topographic positions of the restored lands. Furthermore, the soil organic carbon stocks in the upper 60 cm soils of restored lands, which were varied between 50.08 and 62.21 Mg C ha-1, were higher than 45.90 Mg C ha-1 in natural forest land. Our results indicated that the terracing and reforestation could greatly increase carbon sequestration and accumulation and decrease carbon loss induced by water erosion. And the combination measures can accelerate the restoration of degraded soils when compared to natural forest only. Forest species almost have no impact on the total amount of soil organic carbon during restoration processes, but can significantly influence the activity and stability of soil organic carbon. Combination measures which can provide suitable topography and continuous soil organic carbon supply could be considered in treating degraded soils caused by water erosion.

  6. Fourier transform infrared spectroscopy, a new method for rapid determination of total organic and inorganic carbon and biogenic silica concentration in lake sediments

    DEFF Research Database (Denmark)

    Rosén, Peter; Vogel, Hendrik; Cunningham, Laura

    2010-01-01

    We demonstrate the use of Fourier transform infrared spectroscopy (FTIRS) to make quantitative measures of total organic carbon (TOC), total inorganic carbon (TIC) and biogenic silica (BSi) concentrations in sediment. FTIRS is a fast and cost-effective technique and only small sediment samples...... varied between r = 0.84-0.99 for TOC, r = 0.85-0.99 for TIC, and r = 0.68-0.94 for BSi. Because FTIR spectra contain information on a large number of both inorganic and organic components, there is great potential for FTIRS to become an important tool in paleolimnology....

  7. Soil, vegetation and total organic carbon stock development in self-restoring abandoned vineyards

    Science.gov (United States)

    József Novák, Tibor; Incze, József; Spohn, Marie; Giani, Luise

    2016-04-01

    Abandoned vineyard's soil and vegetation development was studied on Tokaj Nagy-Hill, which is one of the traditional wine-producing regions of Hungary, it is declared as UNESCO World Heritage site as cultural landscape. Spatial distribution and pattern of vineyards were changing during the last several hundreds of years, therefore significant part of abandoned vineyards were subjected to long-term spontaneous secondary succession of vegetation and self-restoration of soils in absence of later cultivation. Two chronosequences of spontaneously regenerating vineyard abandonments, one on south (S-sequence) and one on southwest (SW-sequence) slope with differing times since their abandonment (193, 142, 101, 63, 39 and 14 years), were compiled and studied. The S-sequence was 25-35% sloped and strongly eroded, and the SW-sequence was 17-25% sloped and moderately eroded. The sites were investigated in respect of vegetation characteristics, soil physico-chemical characteristics, total organic carbon stocks (TOC stocks), accumulation rates of total organic carbon (TOC accumulation rates), and soil profiles, which were classified according to the World Reference Base (WRB) 2014. Vegetation development resulted in shrub-grassland mosaics, supplemented frequently by protected forb species and forest development at the earliest abandonment in S-sequence, and predominantly to forest vegetation in SW-sequence, where trees were only absent at the 63 and 14 years old abandonment sites. In all sites soils on level of reference groups according to WRB were classified, and Cambisols, Regosols, Calcisols, Leptosols, Chernozems and Phaeozems were found. Soils of the S-sequence show shallow remnants of loess cover with colluvic and redeposited soil materials containing 15-65% skeletal volcanic rock of weathering products coated by secondary calcium carbonates. The SW-sequence profiles are developed on deep loess or loess derivatives. The calcium-carbonate content was higher in profiles of

  8. Measuring Carbon Footprint of Flexible Pavement Construction Project in Indonesia

    Directory of Open Access Journals (Sweden)

    Utomo Dwi Hatmoko Jati

    2018-01-01

    Full Text Available Road infrastructure in Indonesia is mainly dominated by flexible pavement type. Its construction process, however, has raised concerns in terms of its environment impacts. This study aims to track and measure the carbon footprint of flexible pavement. The objectives are to map the construction process in relation to greenhouse gas (GHG emissions, to quantify them in terms of carbon dioxide equivalents (CO2e as generated by the process of production and transportation of raw materials, and the operation of plant off-site and on-site project. Data collection was done by having site observations and interviews with project stakeholders. The results show a total emissions of 70.888 tonnes CO2e, consisting of 34.248 tonnes CO2e (48.31% off-site activities and 36.640 tonnes CO2e (51.687% on-site activities. The two highest CO2e emissions were generated by the use of plant for asphalt concrete laying activities accounted 34.827 tonnes CO2e (49.130%, and material transportation accounted 24.921 (35.155%. These findings provide a new perspective of the carbon footprint in flexible pavement and suggest the urgent need for the use of more efficient and environmentally friendly plant in construction process as it shows the most significant contribution on the CO2e. This study provides valuable understanding on the environmental impact of typical flexible pavement projects in Indonesia, and further can be used for developing green road framework.

  9. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  10. Remote sensing of water vapour profiles in the framework of the Total Carbon Column Observing Network (TCCON

    Directory of Open Access Journals (Sweden)

    M. Schneider

    2010-12-01

    Full Text Available We show that the near infrared solar absorption spectra recorded in the framework of the Total Carbon Column Observing Network (TCCON can be used to derive the vertical distribution of tropospheric water vapour. The resolution of the TCCON spectra of 0.02 cm−1 is sufficient for retrieving lower and middle/upper tropospheric water vapour concentrations with a vertical resolution of about 3 and 8 km, respectively. We document the good quality of the remotely-sensed profiles by comparisons with coincident in-situ Vaisala RS92 radiosonde measurements. Due to the high measurement frequency, the TCCON water vapour profile data offer novel opportunities for estimating the water vapour variability at different timescales and altitudes.

  11. Measuring the Carbon Intensity of the South African Economy

    DEFF Research Database (Denmark)

    Arndt, Channing; Davies, Rob; Makrelov, Konstantin

    2013-01-01

    We estimate the carbon intensity of industries, products and households in South Africa using data from a high resolution supply-use table. Direct and indirect carbon usage is measured using multiplier methods that capture inter-industry linkages and multi-product supply chains. Carbon intensity ...... or poorer households. Seven percent of emissions arise through marketing margins, implying that carbon pricing should be accompanied by supporting public policies and investments.......We estimate the carbon intensity of industries, products and households in South Africa using data from a high resolution supply-use table. Direct and indirect carbon usage is measured using multiplier methods that capture inter-industry linkages and multi-product supply chains. Carbon intensity...... is found to be high for exports but low for major employing sectors. Middle-income households are the most carbon-intensive consumers. These results suggest that carbon pricing policies (without border tax adjustments) would adversely affect export earnings, but should not disproportionately hurt workers...

  12. Analysis of total polyphenols in wines by FIA with highly stable amperometric detection using carbon nanotube-modified electrodes.

    Science.gov (United States)

    Arribas, Alberto Sánchez; Martínez-Fernández, Marta; Moreno, Mónica; Bermejo, Esperanza; Zapardiel, Antonio; Chicharro, Manuel

    2013-02-15

    The use of glassy carbon electrodes (GCEs) modified with multi-walled carbon nanotube (CNT) films for the continuous monitoring of polyphenols in flow systems has been examined. The performance of these modified electrodes was evaluated and compared to bare GCE by cyclic voltammetry experiments and by flow injection analysis (FIA) with amperometric detection monitoring the response of gallic, caffeic, ferulic and p-coumaric acids in 0.050 M acetate buffer pH 4.5 containing 100 mM NaCl. The GCE modified with CNT dispersions in polyethyleneimine (PEI) provided lower overpotentials, higher sensitivity and much higher signal stability under a dynamic regime than bare GCEs. These properties allowed the estimation of the total polyphenol content in red and white wines with a remarkable long-term stability in the measurements despite the presence of potential fouling substances in the wine matrix. In addition, the versatility of the electrochemical methodology allowed the selective estimation of the easily oxidisable polyphenol fraction as well as the total polyphenol content just by tuning the detection potential at +0.30 or 0.70 V, respectively. The significance of the electrochemical results was demonstrated through correlation studies with the results obtained with conventional spectrophotometric assays for polyphenols (Folin-Ciocalteu, absorbance at 280 nm index and colour intensity index). Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Evaluating the effectiveness of carbon tax for total emission control of carbon dioxide. Systems analysis of a dynamic environmental-economic model

    International Nuclear Information System (INIS)

    Tamura, Hiroyuki; Abe, Makoto; Tomiyama, Shinji; Hatono, Itsuo

    1999-01-01

    This paper deals with how to evaluate the effectiveness of carbon tax (environmental tax) for regulating the carbon dioxide emissions. For this purpose we mainly deal with a primal problem and its dual problem of dynamic linear programming model. The primal problem is formulated by using Leontief type input-output model and the basic idea of commodity stocks. It represents the balance of materials. The dual problem is obtained and interpreted as cash balance. It is clarified in this paper whether the carbon tax is effective to decrease the total amount of carbon dioxide emissions. (author)

  14. FERTILITY AND TOTAL ORGANIC CARBON IN OXISOL UNDER DIFFERENT MANAGEMENT SYSTEMS IN SAVANNAH OF PIAUÍ, BRAZIL

    Directory of Open Access Journals (Sweden)

    Fernando Silva Araújo

    2017-05-01

    Full Text Available The intensive use of natural resources for food production has ruptured the sustainability of agro-ecosystems. In this context, this study aimed to quantify chemical attributes of Oxisol under five management systems: 1 = conventional tillage (CT; 2 = no-tillage system with millet (NT + M; 3 = crop–livestock integration system with soybean (CL + S; 4 = CL with pasture (CL + P; and 5 = native forest (NF. The following soil depths were studied: 0.00–0.05, 0.05–0.10, and 0.10–0.20 m; and the following traits were quantified: total organic carbon (TOC, soil acidity (pH, soil potential acidity (H + Al and soil fertility (Ca, Mg, P and K. All treatments modified soil chemical attributes in comparison to NF (p <0.01. The highest phosphorus and potassium levels were observed under CL + S at all evaluated depths. The NT + M treatment increased Ca and Mg levels in layers 0.0–0.05 and 0.10–0.20, whereas CL + S increased base addition (BA, cation exchange capacity (CEC and  base saturation (BS levels in layer 0.05–0.10 m. Finally, both CL systems improved soil chemical quality, increased surface TOC and carbon stock in depth.

  15. TRANC - a novel fast-response converter to measure total reactive atmospheric nitrogen

    Science.gov (United States)

    Marx, O.; Brümmer, C.; Ammann, C.; Wolff, V.; Freibauer, A.

    2012-05-01

    The input and loss of plant available nitrogen (reactive nitrogen: Nr) from/to the atmosphere can be an important factor for the productivity of ecosystems and thus for its carbon and greenhouse gas exchange. We present a novel converter for reactive nitrogen (TRANC: Total Reactive Atmospheric Nitrogen Converter), which offers the opportunity to quantify the sum of all airborne reactive nitrogen compounds (∑Nr) in high time resolution. The basic concept of the TRANC is the full conversion of all Nr to nitrogen monoxide (NO) within two reaction steps. Initially, reduced Nr compounds are being oxidised, and oxidised Nr compounds are thermally converted to lower oxidation states. Particulate Nr is being sublimated and oxidised or reduced afterwards. In a second step, remaining higher nitrogen oxides or those generated in the first step are catalytically converted to NO with carbon monoxide used as reduction gas. The converter is combined with a fast response chemiluminescence detector (CLD) for NO analysis and its performance was tested for the most relevant gaseous and particulate Nr species under both laboratory and field conditions. Recovery rates during laboratory tests for NH3 and NO2 were found to be 95 and 99%, respectively, and 97% when the two gases were combined. In-field longterm stability over an 11-month period was approved by a value of 91% for NO2. Effective conversion was also found for ammonium and nitrate containing particles. The recovery rate of total ambient Nr was tested against the sum of individual measurements of NH3, HNO3, HONO, NH4+, NO3-, and NOx using a combination of different well-established devices. The results show that the TRANC-CLD system precisely captures fluctuations in ∑Nr concentrations and also matches the sum of all individual Nr compounds measured by the different single techniques. The TRANC features a specific design with very short distance between the sample air inlet and the place where the thermal and catalytic

  16. TRANC – a novel fast-response converter to measure total reactive atmospheric nitrogen

    Directory of Open Access Journals (Sweden)

    V. Wolff

    2012-05-01

    Full Text Available The input and loss of plant available nitrogen (reactive nitrogen: Nr from/to the atmosphere can be an important factor for the productivity of ecosystems and thus for its carbon and greenhouse gas exchange. We present a novel converter for reactive nitrogen (TRANC: Total Reactive Atmospheric Nitrogen Converter, which offers the opportunity to quantify the sum of all airborne reactive nitrogen compounds (∑Nr in high time resolution. The basic concept of the TRANC is the full conversion of all Nr to nitrogen monoxide (NO within two reaction steps. Initially, reduced Nr compounds are being oxidised, and oxidised Nr compounds are thermally converted to lower oxidation states. Particulate Nr is being sublimated and oxidised or reduced afterwards. In a second step, remaining higher nitrogen oxides or those generated in the first step are catalytically converted to NO with carbon monoxide used as reduction gas. The converter is combined with a fast response chemiluminescence detector (CLD for NO analysis and its performance was tested for the most relevant gaseous and particulate Nr species under both laboratory and field conditions. Recovery rates during laboratory tests for NH3 and NO2 were found to be 95 and 99%, respectively, and 97% when the two gases were combined. In-field longterm stability over an 11-month period was approved by a value of 91% for NO2. Effective conversion was also found for ammonium and nitrate containing particles. The recovery rate of total ambient Nr was tested against the sum of individual measurements of NH3, HNO3, HONO, NH4+, NO3−, and NOx using a combination of different well-established devices. The results show that the TRANC-CLD system precisely captures fluctuations in ∑Nr concentrations and also matches the sum of all individual Nr compounds measured by the different single techniques. The TRANC features a specific design with very short distance between the sample air inlet and the place where the thermal

  17. Measuring Urban Carbon Footprint from Carbon Flows in the Global Supply Chain.

    Science.gov (United States)

    Hu, Yuanchao; Lin, Jianyi; Cui, Shenghui; Khanna, Nina Zheng

    2016-06-21

    A global multiregional input-output (MRIO) model was built for eight Chinese cities to track their carbon flows. For in-depth understanding of urban carbon footprint from the perspectives of production, consumption, and trade balance, four kinds of footprints and four redefined measurement indicators were calculated. From the global supply chain, urban carbon inflows from Mainland China were larger than outflows, while the carbon outflows to European, principal North American countries and East Asia were much larger than inflows. With the rapid urbanization of China, Construction was the largest consumer and Utilities was the largest producer. Cities with higher consumption (such as Dalian, Tianjin, Shanghai, and Beijing) should change their consumption patterns, while cities with lower production efficiency (such as Dalian, Shanghai, Ningbo, and Chongqing) should improve their technology. The cities of net carbon consumption tended to transfer carbon emissions out of them by trading in carbon-intensive products, while the cities of net carbon production tended to produce carbon-intensive products for nonlocal consumers. Our results indicated that urban carbon abatement requires not only rational consumption and industrial symbiosis at the city level, but also tighter collaboration along all stages of the global supply chain.

  18. Use of a pulsed neutron generator for in vivo measurement of body carbon

    International Nuclear Information System (INIS)

    Kehayias, J.J.; Ellis, K.J.; Cohn, S.H.; Yasumura, S.

    1986-01-01

    The measurement of total body fat is of importance in studies of nutritional assessment, dietary regimens, and for the management of obesity. In the past, fat has been determined either by anthropometric methods, which introduce high uncertainties, or by model-dependent estimation of fat-free tissue. The validity, however, of the different models in disease is questionable. Total body carbon measurements provide a more direct evaluation of body fat both in normal subjects and in patients. The authors present here a facility for carbon measurements without the use of a major accelerator. The same facility can be used for the measurement of other major body elements and for the evaluation of the body's compartments. Carbon is measured in vivo through neutron inelastic scattering, by detecting the 4.44 MeV gamma rays. A miniature (10 cm long) 14 MeV D-T neutron generator is used. The short half-life of the 4.44 MeV state of carbon requires detection of the gamma rays simultaneously with the 10 μs neutron pulse. Generators with low pulsing rate were found inappropriate for carbon measurement because of their low duty-cycle (high neutron output during pulse). The detection system consists of NaI(T1) detectors and fast electronics for handling the high even rate during the neutron pulse. A description of the facility and an evaluation of the technique will be presented

  19. Side-by-side comparison of analytical techniques; organic acids, total organic carbon, and anions in PWR secondary cycles

    International Nuclear Information System (INIS)

    Hobart, S.A.; Byers, W.A.; Miller, M.R.; Richards, J.; Silva, H.; Palino, G.F.; Wall, P.S.

    1986-01-01

    Total Organic Carbon TOC samples should be analyzed no later than one week after they are taken and they should be stored in a refrigerated condition, if at all possible. It can be inferred that for TOC levels in the range of 50 to 120 ppb, state-of-the-art sampling and analysis techniques can produce results varying by 20 to 50 ppb. Any proposed limits for TOC should be reviewed in that light. Agreement between anion results appeared to improve over the course of the project. Both contractors agree that increased attention and care with sampling and analytical techniques probably accounted for this improvement. Utility personnel can therefore conclude that proper employee training, supervision, and motivation for proper sampling and analysis are critical if accurate anion results are to be obtained. Resonable agreement between calculated and measured values of cation conductivity suggest that both contractors had accurately determined all major anionic species

  20. Measurement of carbon fixation and allocation using 11C-labeled carbon dioxide

    International Nuclear Information System (INIS)

    Strain, B.R.; Goeschl, J.D.; Jaeger, C.H.; Fares, Y.; Magnuson, C.E.; Nelson, C.E.

    1983-01-01

    This paper describes the use of continuously produced and applied 11 C in measurements of carbon dioxide assimilation and C movement in plant research. This technique differs from the pulsing type 11 C research underway in other laboratories by being continuous and on-line with computer analysis making steady-state measurements of carbon fixation and movement possible. The studies to be described here make clear the advantages of using continuously produced and applied short half-lived isotopes

  1. Total organic carbon removal from a chemical lab’s wastewater using Fenton’s reagent

    Directory of Open Access Journals (Sweden)

    Oscar Mauricio Martínez Ávila

    2013-05-01

    Full Text Available Treating industrial wastewater represents a serious problem nowadays; it requires a strong understanding of the particular systems and (in most of cases ad hoc solutions. This work describes the use of Fenton’s reagent (reaction between H2O2 and Fe(II for removing total organic carbon (TOC from a particular chemical laboratory’s lab-scale batch reactor wastewater. Some operating variables (hydrogen peroxide and ferrous ion concentration, temperature and pH were evaluated regarding final TOC removal. An economic optimisation was made by means of a second order polynomial model representing these variables’ behaviour regarding TOC removal (0.94 R2. The highest experimentally reached TOC removal was 88.8% at 50 mg/L [Fe(II]0, 50 mM [H2O2]0 , pH=2.8 at 80oC, while 53.9% was obtained in optimised conditions, i.e. 36 mg/L [Fe(II]0 , 45.5 mM [H2O2]0 , pH=2.6 at 20°C. It was found that the Fenton process could achieve 41% removal, even in adverse conditions (pH close to 6. It was noted from the analysis that both H2O2 concentration and temperature had a powerful effect on organic matter degradation efficiency, as well as on total treatment cost.

  2. A new method for rapid determination of carbohydrate and total carbon concentrations using UV spectrophotometry.

    Science.gov (United States)

    Albalasmeh, Ammar A; Berhe, Asmeret Asefaw; Ghezzehei, Teamrat A

    2013-09-12

    A new UV spectrophotometry based method for determining the concentration and carbon content of carbohydrate solution was developed. This method depends on the inherent UV absorption potential of hydrolysis byproducts of carbohydrates formed by reaction with concentrated sulfuric acid (furfural derivatives). The proposed method is a major improvement over the widely used Phenol-Sulfuric Acid method developed by DuBois, Gilles, Hamilton, Rebers, and Smith (1956). In the old method, furfural is allowed to develop color by reaction with phenol and its concentration is detected by visible light absorption. Here we present a method that eliminates the coloration step and avoids the health and environmental hazards associated with phenol use. In addition, avoidance of this step was shown to improve measurement accuracy while significantly reducing waiting time prior to light absorption reading. The carbohydrates for which concentrations and carbon content can be reliably estimated with this new rapid Sulfuric Acid-UV technique include: monosaccharides, disaccharides and polysaccharides with very high molecular weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Carbon emission scenarios of China's power sector: Impact of controlling measures and carbon pricing mechanism

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    2018-03-01

    Full Text Available The study constructs a low-carbon path analysis model of China's power sector based on TIMES model and presents a comparative analysis of carbon emissions under Reference, Low-Carbon and Enhanced Low-Carbon scenarios, and the main difference of the three scenarios is manifested by policy selection and policy strength. The conclusions are drawn as follows: (1 The peak of carbon emission in China's power sector will range from 4.0 GtCO2 to 4.8 GtCO2, which implies an increment of 0.5–1.3 billion or 14%–35% from the 2015 levels. (2 Introducing carbon price is an effective way to inhibit coal power and promote non-fossil fuels and Carbon Capture, Utilization and Storage applications (CCUS. The carbon emission reduction effects will gradually increase with carbon price. When the carbon price attains to CN¥150 t−1CO2, the CO2 emission can decrease by 36% than that without carbon price. (3 CCUS is one of important contributing factor to reduce CO2 emission in power sector. Generally speaking, the development of non-fossil fuels and energy efficiency improvement are two main drivers for carbon mitigation, but once the carbon price reaches up to CN¥106 t−1CO2, the CCUS will be required to equip with thermal power units and its contribution on carbon emission reduction will remarkably increase. When carbon price increases to CN¥150 t−1CO2 in 2050, the application of CCUS will account for 44% of total emission reduction. (4 In the scenario with carbon price of CN¥150 t−1CO2, power sector would be decarbonized significantly, and the CO2 intensity will be 0.22 kgCO2 (kW h−1, but power sector is far from the goal that achieving net zero emission. In order to realize the long-term low greenhouse gas emission development goal that proposed by the Paris Agreement, more efforts are needed to be put to further reduce the carbon emission reduction of power sector. Based on the above scenario analysis, the study proposes four recommendations

  4. Algal C-14 and total carbon metabolisms 2. Experimental observations with the diatom Skeletonema costatum

    DEFF Research Database (Denmark)

    Williams, P.J.L.; Robinson, C.; Søndergaard, M.

    1996-01-01

    Three sets of comparisons of net and gross inorganic carbon assimilation and C-14 uptake were made with an axenic culture of Skeletonema costatum. The comparisons showed that in the physiological window studied (10-20% of the intrinsic generation time and gross photosynthesis/respiration ratios...... of 2-3), C-14 uptake into the particulate plus the dissolved fractions approximated to net photosynthesis. Rate constants derived from the chemically determined changes were used to parameterize models that accounted for the respiration of photosynthetic products and for the recycling of respiratory CO......2. The conclusion drawn was that over the time scale studied, the C-14 technique was measuring net photosynthesis, consistent with essentially 100% recycling of respiratory CO2. The study has shown that we now possess the basis to make a rigorous analysis of net, gross CO2 fixation and net C-14...

  5. Total disintegration of the carbon nucleus by 40 GeV/c π- mesons

    International Nuclear Information System (INIS)

    Angelov, N.; Lyubimov, V.B.; Solov'ev, M.I.; Tuvendorzh, D.; Anoshin, A.I.; Sulejmanov, M.

    1978-01-01

    Studied is the phenomenon of a complete disintegration (CD) of a nucleus in the π -12 C interactions at the π - momentum equal to 40 GeV/c. The experiments were carried out in a 2-meter propane chamber. Momenta and emission angles of all charged particles were measured. The D probability for a carbon nucleus turned out to be equal to (7.0+-0.3)%. No difference was observed between the events of CD and the ''usual'' π -12 C interaction based on the consideration of angular and momentum distributions of π +- mesons and protons. The leading effect in the events with the target-nucleus CD is weaker than in all the rest π -12 C interactions

  6. Quantitative measurement of carbon nanotubes released from their composites using thermal carbon analysis

    International Nuclear Information System (INIS)

    Ogura, I; Honda, K; Shigeta, M; Kotake, M; Uejima, M

    2015-01-01

    The ability of thermal carbon analysis to determine CNTs was evaluated in the presence of a polymer (Polystyrene, PS). Samples placed in an Au (Pt) foil boat were measured using a thermal-carbon analyzer, and the results were compared with gravimetric measurements of sample masses obtained using an ultra-microbalance. First, debris from the polymer without CNTs (i.e., PS debris) was analyzed. The amount of PS debris detected in the organic carbon (OC) fraction was found to be in good agreement with the gravimetrically measured mass of the PS debris, while the amount of pyrolyticallygenerated carbon soot detected in the elemental carbon (EC) fraction was negligible. Next, single-wall CNT (AIST/TASC Super-Growth) powder was analyzed, and the amount of the CNT powder detected in the EC fraction was found to be 95-96% of the gravimetrically measured mass of the CNT powder. Subsequently, a mixture of the PS debris and the CNT powder was analyzed, and the amounts of detected OC and EC were found to be comparable to the gravimetrically measured masses of the PS debris and the CNT powder, respectively. Finally, debris from 5 wt% CNT-PS composites was analyzed, and amounts of OC and EC detected were found to be approximately comparable to the estimated masses of the PS and the CNTs in the debris of CNT-PS composite, respectively. The results therefore indicate thermal carbon analysis is capable of determining CNTs in the presence of PS. (paper)

  7. Tidally driven export of dissolved organic carbon, total mercury, and methylmercury from a mangrove-dominated estuary

    Science.gov (United States)

    Bergamaschi, B.A.; Krabbenhoft, D.P.; Aiken, G.R.; Patino, E.; Rumbold, D.G.; Orem, W.H.

    2012-01-01

    The flux of dissolved organic carbon (DOC) from mangrove swamps accounts for 10% of the global terrestrial flux of DOC to coastal oceans. Recent findings of high concentrations of mercury (Hg) and methylmercury (MeHg) in mangroves, in conjunction with the common co-occurrence of DOC and Hg species, have raised concerns that mercury fluxes may also be large. We used a novel approach to estimate export of DOC, Hg, and MeHg to coastal waters from a mangrove-dominated estuary in Everglades National Park (Florida, USA). Using in situ measurements of fluorescent dissolved organic matter as a proxy for DOC, filtered total Hg, and filtered MeHg, we estimated the DOC yield to be 180 (??12.6) g C m -2 yr -1, which is in the range of previously reported values. Although Hg and MeHg yields from tidal mangrove swamps have not been previously measured, our estimated yields of Hg species (28 ?? 4.5 ??g total Hg m -2 yr -1 and 3.1 ?? 0.4 ??g methyl Hg m -2 yr -1) were five times greater than is typically reported for terrestrial wetlands. These results indicate that in addition to the well documented contributions of DOC, tidally driven export from mangroves represents a significant potential source of Hg and MeHg to nearby coastal waters. ?? 2011 American Chemical Society.

  8. Measurements of Total and Partial Charge-changing Cross Sections for 200-400 MeV/nucleon 12C in Water and Polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Toshito, T.; /CREST, Japan Sci. Tech. Corp. /KEK, Tsukuba; Kodama, K.; /Aichi U. of Education; Sihver, L.; /Chalmers U. Tech.; Yusa, K.; /Gunma U., Maebashi; Ozaki, M.; /JAXA, Sagamihara; Amako, K.; Kameoka, S.; Murakami, K.; Sasaki, T.; /KEK, Tsukuba; Aoki, S.; /Kobe U.; Ban, T.; Fukuda, T.; Komatsu, M.; Kubota, H.; Naganawa, N.; Nakamura, T.; Nakano, T.; Natsume, M.; Niwa, K.; Takahashi, S.; Yoshida, J.; /Nagoya U. /Naruto U. of Education /NIRS, Chiba /SLAC /Toho U.

    2011-11-10

    We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for validating and improving carbon ion therapy treatment planning systems, and for estimating the radiological risks for personnel on space missions, since carbon is a significant component of the Galactic Cosmic Rays.

  9. Using measurements for evaluation of black carbon modeling

    Directory of Open Access Journals (Sweden)

    S. Gilardoni

    2011-01-01

    Full Text Available The ever increasing use of air quality and climate model assessments to underpin economic, public health, and environmental policy decisions makes effective model evaluation critical. This paper discusses the properties of black carbon and light attenuation and absorption observations that are the key to a reliable evaluation of black carbon model and compares parametric and nonparametric statistical tools for the quantification of the agreement between models and observations. Black carbon concentrations are simulated with TM5/M7 global model from July 2002 to June 2003 at four remote sites (Alert, Jungfraujoch, Mace Head, and Trinidad Head and two regional background sites (Bondville and Ispra. Equivalent black carbon (EBC concentrations are calculated using light attenuation measurements from January 2000 to December 2005. Seasonal trends in the measurements are determined by fitting sinusoidal functions and the representativeness of the period simulated by the model is verified based on the scatter of the experimental values relative to the fit curves. When the resolution of the model grid is larger than 1° × 1°, it is recommended to verify that the measurement site is representative of the grid cell. For this purpose, equivalent black carbon measurements at Alert, Bondville and Trinidad Head are compared to light absorption and elemental carbon measurements performed at different sites inside the same model grid cells. Comparison of these equivalent black carbon and elemental carbon measurements indicates that uncertainties in black carbon optical properties can compromise the comparison between model and observations. During model evaluation it is important to examine the extent to which a model is able to simulate the variability in the observations over different integration periods as this will help to identify the most appropriate timescales. The agreement between model and observation is accurately described by the overlap of

  10. Annual measurements of gain and loss in aboveground carbon density

    Science.gov (United States)

    Baccini, A.; Walker, W. S.; Carvalho, L.; Farina, M.; Sulla-menashe, D. J.; Houghton, R. A.

    2017-12-01

    Tropical forests hold large stores of carbon, but their net carbon balance is uncertain. Land use and land-cover change (LULCC) are believed to release between 0.81 and 1.14 PgC yr-1, while intact native forests are thought to be a net carbon sink of approximately the same magnitude. Reducing the uncertainty of these estimates is not only fundamental to the advancement of carbon cycle science but is also of increasing relevance to national and international policies designed to reduce emissions from deforestation and forest degradation (e.g., REDD+). Contemporary approaches to estimating the net carbon balance of tropical forests rely on changes in forest area between two periods, typically derived from satellite data, together with information on average biomass density. These approaches tend to capture losses in biomass due to deforestation (i.e., wholesale stand removals) but are limited in their sensitivity to forest degradation (e.g., selective logging or single-tree removals), which can account for additional biomass losses on the order of 47-75% of deforestation. Furthermore, while satellite-based estimates of forest area loss have been used successfully to estimate associated carbon losses, few such analyses have endeavored to determine the rate of carbon sequestration in growing forests. Here we use 12 years (2003-2014) of pantropical satellite data to quantify net annual changes in the aboveground carbon density of woody vegetation (MgC ha-1yr-1), providing direct, measurement-based evidence that the world's tropical forests are a net carbon source of 425.2 ± 92.0 Tg C yr-1. This net release of carbon consists of losses of 861.7 ± 80.2 Tg C yr-1 and gains of -436.5 ± 31.0 Tg C yr-1 . Gains result from forest growth; losses result from reductions in forest area due to deforestation and from reductions in biomass density within standing forests (degradation), with the latter accounting for 68.9% of overall losses. Our findings advance previous research

  11. Measurement of the total cross section with ALFA Detector at ATLAS

    CERN Document Server

    Trzebinski, M; The ATLAS collaboration

    2017-01-01

    The main goals of the Absolute Luminosity For ATLAS (ALFA) detector is to provide an absolute luminosity and total cross section measurement. The measurement method used, the detector alignment and the quality of the collected data are discussed.

  12. Towards a Total Cross Section Measurement with the ALFA Detector at ATLAS

    CERN Document Server

    Trzebiński, Maciej

    2013-01-01

    The main goals of the Absolute Luminosity For ATLAS (ALFA) detector is to provide an absolute luminosity and total cross section measurement. The measurement method used, the detector alignment and the quality of the collected data are discussed.

  13. Suppression/reducing method for total organic carbon in feedwater/condensate

    International Nuclear Information System (INIS)

    Maeda, Katsuharu.

    1993-01-01

    The present invention suppresses/reduces the concentration of the total organic carbon before the startup of a reactor, to decrease (TOC) which is brought into the reactor upon startup of the operation and suppress/moderate degradation of water quality of reactor water. That is, in-service period of a condensate desalting tower is shortened, to avoid concentration increase of TOC in feed water/condensate which is leached out from the condensate desalting tower. The condensate desalting towers are put to in-service for the entire towers after increasing the vacuum degree of the condensator, to suppress leaching of TOC from the condensate desalting tower. Further, upon startup of a nuclear power plant, when the condensate desalting tower is put to in-service, condensate filters of the entire towers are previously back-washed and regenerated to remove TOC efficiently. By these procedures, TOC brought from a water supply system upon startup of the plant is thermally decomposed or radiolyzed in the reactor, thereby enabling to suppress/avoid worsening of water quality of reactor water caused by generated ion impurities. (I.S.)

  14. [Accumulation of soil organic carbon and total nitrogen in Pinus yunnanensis forests at different age stages].

    Science.gov (United States)

    Miao, Juan; Zhou, Chuan-Yan; Li, Shi-Jie; Yan, Jun-Hua

    2014-03-01

    Taking three Pinus yunnanensis forests at different ages (19, 28 and 45 a) in Panxian County of Guizhou Province as test objects, we investigated vertical distributions and accumulation rates of soil organic carbon (SOC) and total nitrogen (TN), as well as their relationships with soil bulk density. For the three forests at different age stages, SOC and TN changed consistently along the soil profile, declining with the soil depth. Both SOC and TN storage increased with the forest age. The SOC and TN storage amounts were 96.24, 121.65 and 148.13 t x hm(-2), and 10.76, 12.96 and 13.08 t x hm(-2) for the forest stands with 19 a, 28 a and 45 a, respectively. SOC had a significant positive correlation with soil TN, while both of them had a significant negative relationship with the soil bulk density. The accumulation rates of both SOC and TN storage at different growth periods were different, and the rate in the period from age 19 to 28 was higher than in the period from age 28 to 45.

  15. High purity heavy water production: need for total organic carbon determination in process water streams

    International Nuclear Information System (INIS)

    Ayushi; Kumar, Sangita D.; Reddy, A.V.R.; Vithal, G.K.

    2009-01-01

    In recent times, demand for high purity heavy water (99.98% pure) in industries and laboratories has grown by manifold. Its application started in nuclear industry with the design of CANDU reactor, which uses natural uranium as fuel. In this reactor the purest grade of heavy water is used as the moderator and the primary coolant. Diverse industrial applications like fibre optics, medicine, semiconductors etc. use high purity heavy water extensively to achieve better performance of the specific material. In all these applications there is a stringent requirement that the total organic carbon content (TOC) of high purity heavy water should be very low. This is because the presence of TOC can lead to adverse interactions in different applications. To minimize the TOC content in the final product there is a need to monitor and control the TOC content at each and every stage of heavy water production. Hence a simple, rapid and accurate method was developed for the determination of TOC content in process water samples. The paper summarizes the results obtained for the TOC content in the water samples collected from process streams of heavy water production plant. (author)

  16. Preozonation Effect on Total Organic Carbon Removal in Surface Water Treatment

    Directory of Open Access Journals (Sweden)

    Ali Torabian

    2006-06-01

    Full Text Available In drinking water treatment, preozonation is often applied in order to control the microorganisms and taste and odor causing materials, which may influence organics removal by preoxidation and adsorption. Using commercial and natural water humic substances, the positive effect of preozonation as an aid to coagulation-flocculation of these compounds was confirmed by removal of TOC removal in Tehranpars Water Treatment Plant in Tehran. These experiments were conducted as bench-scale studies through a series of jar tests using different pH coagulant dosages and total organic carbon concentration of approximately 4, 8 and 12 mg/L. In addition to TOC removal, the existence of an optimum preozonation dose (OPZD was also confirmed. Experiments show that preozonation can improve coagulation and flocculation depending on influent TOC concentration of raw water. The results demonstrate different effects of preozonation on removal of influent TOC. Preozonation showed a positive effect on a system with low influent TOC and very low molecular weight (noncolloidal humic substances.

  17. Basin-scale changes of total organic carbon profiles in the eastern South Atlantic

    Directory of Open Access Journals (Sweden)

    X. A. Alvarez-Salgado

    2001-03-01

    Full Text Available Total organic carbon (TOC samples were collected at 6 stations spaced ~800 km apart in the eastern South Atlantic, from the Equator to 45°S along 9°W. Analyses were performed by high temperature catalytic oxidation (HTCO in the base laboratory. Despite the complex advection and mixing patterns of North Atlantic and Antarctic waters with extremely different degrees of ventilation, TOC levels below 500 m are quasi-constant at 55±3 µmol C l-1, pointing to the refractory nature of deep-water TOC. On the other hand, a TOC excess from 25 to 38 g C m-2 is observed in the upper 100 m of the permanently stratified nutrient-depleted Equatorial, Subequatorial and Subtropical upper ocean, where vertical turbulent diffusion is largely prevented. Conversely, TOC levels in the nutrient-rich upper layer of the Subantarctic Front only exceeds 9 g C m-2 the deep-water baseline. As much as 70% of the TOC variability in the upper 500 m is due to simple mixing of reactive TOC formed in the surface layer and refractory TOC in deep ocean waters, with a minor contribution (13% to oxygen consumption in the prominent subsurface AOU maximum at 200-400 m depth.

  18. Sky brightness and color measurements during the 21 August 2017 total solar eclipse.

    Science.gov (United States)

    Bruns, Donald G; Bruns, Ronald D

    2018-06-01

    The sky brightness was measured during the partial phases and during totality of the 21 August 2017 total solar eclipse. A tracking CCD camera with color filters and a wide-angle lens allowed measurements across a wide field of view, recording images every 10 s. The partially and totally eclipsed Sun was kept behind an occulting disk attached to the camera, allowing direct brightness measurements from 1.5° to 38° from the Sun. During the partial phases, the sky brightness as a function of time closely followed the integrated intensity of the unobscured fraction of the solar disk. A redder sky was measured close to the Sun just before totality, caused by the redder color of the exposed solar limb. During totality, a bluer sky was measured, dimmer than the normal sky by a factor of 10,000. Suggestions for enhanced measurements at future eclipses are offered.

  19. Local carbon diffusion coefficient measurement in the S-1 spheromak

    International Nuclear Information System (INIS)

    Mayo, R.M.; Levinton, F.M.; Meyerhofer, D.D.; Chu, T.K.; Paul, S.F.; Yamada, M.

    1988-10-01

    The local carbon diffusion coefficient was measured in the S - 1 spheromak by detecting the radial spread of injected carbon impurity. The radial impurity density profile is determined by the balance of ionization and diffusion. Using measured local electron temperature T/sub e/ and density n/sub e/, the ionization rate is determined from which the particle diffusion coefficient is inferred. The results found in this work are consistent with Bohm diffusion. The absolute magnitude of D/sub /perpendicular// was determined to be (4/approximately/6) /times/ D/sub Bohm/. 25 refs., 13 figs., 2 tabs

  20. Taking Stock of Circumboreal Forest Carbon With Ground Measurements, Airborne and Spaceborne LiDAR

    Science.gov (United States)

    Neigh, Christopher S. R.; Nelson, Ross F.; Ranson, K. Jon; Margolis, Hank A.; Montesano, Paul M.; Sun, Guoqing; Kharuk, Viacheslav; Naesset, Erik; Wulder, Michael A.; Andersen, Hans-Erik

    2013-01-01

    The boreal forest accounts for one-third of global forests, but remains largely inaccessible to ground-based measurements and monitoring. It contains large quantities of carbon in its vegetation and soils, and research suggests that it will be subject to increasingly severe climate-driven disturbance. We employ a suite of ground-, airborne- and space-based measurement techniques to derive the first satellite LiDAR-based estimates of aboveground carbon for the entire circumboreal forest biome. Incorporating these inventory techniques with uncertainty analysis, we estimate total aboveground carbon of 38 +/- 3.1 Pg. This boreal forest carbon is mostly concentrated from 50 to 55degN in eastern Canada and from 55 to 60degN in eastern Eurasia. Both of these regions are expected to warm >3 C by 2100, and monitoring the effects of warming on these stocks is important to understanding its future carbon balance. Our maps establish a baseline for future quantification of circumboreal carbon and the described technique should provide a robust method for future monitoring of the spatial and temporal changes of the aboveground carbon content.

  1. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  2. Total Organic Carbon Distribution and Bacterial Cycling Across A Geostrophic Front In Mediterranean Sea. Implications For The Western Basin Carbon Cycle

    Science.gov (United States)

    Sempere, R.; van Wambeke, F.; Bianchi, M.; Dafner, E.; Lefevre, D.; Bruyant, F.; Prieur, L.

    We investigated the dynamic of the total organic carbon (TOC) pool and the role it played in the carbon cycle during winter 1997-1998 in the Almeria-Oran jet-front (AOF) system resulting from the spreading of Atlantic surface water through the Gibraltar Strait in the Alboran Sea (Southwestern Mediterranean Sea). We determined TOC by using high temperature combustion technique (HTC) and bacterial produc- tion (BP; via [3H] leucine incorporation) during two legs in the frontal area. We also estimated labile TOC (l-TOC) and bacterial growth efficiency (BGE) by performing TOC biodegradation experiments on board during the cruise whereas water column semi-labile (sl-TOC), and refractory-TOC were determined from TOC profile exami- nation. These results are discussed in relation with current velocity measured by using accoustic doppler current profiler (ADCP). Lowest TOC stocks (6330-6853 mmol C m-2) over 0-100 m were measured in the northern side of the geostrophic Jet which is also the highest dynamic area (horizontal speed of 80 cm s-1 in the first 100 m di- rected eastward). Our results indicated variable turnover times of sl-TOC across the Jet-Front system, which might be explained by different coupling of primary produc- tion and bacterial production observed in these areas. We also estimated TOC and sl-TOC transports within the Jet core off the Alboran Sea as well as potential CO2 production through bacterial respiration produced from sl-TOC assimilation by het- erotrophic bacteria.

  3. In situ spectrophotometric measurement of dissolved inorganic carbon in seawater

    Science.gov (United States)

    Liua, Xuewu; Byrne, Robert H.; Adornato, Lori; Yates, Kimberly K.; Kaltenbacher, Eric; Ding, Xiaoling; Yang, Bo

    2013-01-01

    Autonomous in situ sensors are needed to document the effects of today’s rapid ocean uptake of atmospheric carbon dioxide (e.g., ocean acidification). General environmental conditions (e.g., biofouling, turbidity) and carbon-specific conditions (e.g., wide diel variations) present significant challenges to acquiring long-term measurements of dissolved inorganic carbon (DIC) with satisfactory accuracy and resolution. SEAS-DIC is a new in situ instrument designed to provide calibrated, high-frequency, long-term measurements of DIC in marine and fresh waters. Sample water is first acidified to convert all DIC to carbon dioxide (CO2). The sample and a known reagent solution are then equilibrated across a gas-permeable membrane. Spectrophotometric measurement of reagent pH can thereby determine the sample DIC over a wide dynamic range, with inherent calibration provided by the pH indicator’s molecular characteristics. Field trials indicate that SEAS-DIC performs well in biofouling and turbid waters, with a DIC accuracy and precision of ∼2 μmol kg–1 and a measurement rate of approximately once per minute. The acidic reagent protects the sensor cell from biofouling, and the gas-permeable membrane excludes particulates from the optical path. This instrument, the first spectrophotometric system capable of automated in situ DIC measurements, positions DIC to become a key parameter for in situ CO2-system characterizations.

  4. Single particle composition measurements of artificial Calcium Carbonate aerosols

    Science.gov (United States)

    Zorn, S. R.; Mentel, T. F.; Schwinger, T.; Croteau, P. L.; Jayne, J.; Worsnop, D. R.; Trimborn, A.

    2012-12-01

    Mineral dust, with an estimated total source from natural and anthropogenic emissions of up to 2800 Tg/yr, is one of the two largest contributors to total aerosol mass, with only Sea salt having a similar source strength (up to 2600 Tg/yr). The composition of dust particles varies strongly depending on the production process and, most importantly, the source location. Therefore, the composition of single dust particles can be used both to trace source regions of air masses as well as to identify chemical aging processes. Here we present results of laboratory studies on generating artificial calcium carbonate (CaCO3) particles, a model compound for carbonaceous mineral dust particles. Particles were generated by atomizing an aqueous hydrogen carbonate solution. Water was removed using a silica diffusion dryer., then the particles were processed in an oven at temperatures up to 900°C, converting the hydrogen carbonate to its anhydrous form. The resulting aerosol was analyzed using an on-line single particle laser ablation aerosol particle time-of-flight mass spectrometer (LAAPTOF). The results confirm the conversion to calcium carbonate, and validate that the produced particles indeed can be used as a model compound for carbonaceous dust aerosols.

  5. Elevated atmospheric carbon dioxide concentrations amplify Alternaria alternata sporulation and total antigen production

    Science.gov (United States)

    Background: Although the association between rising levels of carbon dioxide, the principle anthropogenic greenhouse gas, and pollen production has been established, few data are available regarding the function of rising carbon dioxide on quantitative or qualitative changes in allergenic fungal sp...

  6. Carbon-14 measurements and characterization of dissolved organic carbon in ground water

    International Nuclear Information System (INIS)

    Murphy, E.M.

    1987-01-01

    Carbon-14 was measured in the dissolved organic carbon (DOC) in ground water and compared with 14 C analyses of dissolved inorganic carbon (DIC). Two field sites were used for this study; the Stripa mine in central Sweden, and the Milk River Aquifer in southern Alberta, Canada. The Stripa mine consists of a Precambrian granite dominated by fracture flow, while the Milk River Aquifer is a Cretaceous sandstone aquifer characterized by porous flow. At both field sites, 14 C analyses of the DOC provide additional information on the ground-water age. Carbon-14 was measured on both the hydrophobic and hydrophilic organic fractions of the DOC. The organic compounds in the hydrophobic and hydrophilic fractions were also characterized. The DOC may originate from kerogen in the aquifer matrix, from soil organic matter in the recharge zone, of from a combination of these two sources. Carbon-14 analyses, along with characterization of the organics, were used to determine this origin. Carbon-14 analyses of the hydrophobic fraction in the Milk River Aquifer suggest a soil origin, while 14 C analyses of the hydrophilic fraction suggest an origin within the Cretaceous sediments (kerogen) or from the shale in contact with the aquifer

  7. Distribution of surficial sediment in Long Island Sound and adjacent waters: Texture and total organic carbon

    Science.gov (United States)

    Poppe, L.J.; Knebel, H.J.; Mlodzinska, Z.J.; Hastings, M.E.; Seekins, B.A.

    2000-01-01

    The surficial sediment distribution within Long Island Sound has been mapped and described using bottom samples, photography, and sidescan sonar, combined with information from the geologic literature. The distributions of sediment type and total organic carbon (TOC) reveal several broad trends that are largely related to the sea-floor geology, the bathymetry, and the effects of modern tidal- and wind-driven currents. Sediment types are most heterogeneous in bathymetrically complex and shallow nearshore areas; the heterogeneity diminishes and the texture fines with decreasing bottom-current energy. Lag deposits of gravel and gravelly sand dominate the surficial sediment texture in areas where bottom currents are the strongest (such as where tidal flow is constricted) and where glacial till crops out at the sea floor. Sand is the dominant sediment type in areas characterized by active sediment transport and in shallow areas affected by fine-grained winnowing. Silty sand and sand-silt-clay mark transitions within the basin from higher- to lower-energy environments, suggesting a diminished hydraulic ability to sort and transport sediment. Clayey silt and silty clay are the dominant sediment types accumulating in the central and western basins and in other areas characterized by long-term depositional environments. The amount of TOC in the sediments of Long Island Sound varies inversely with sediment grain size. Concentrations average more than 1.9% (dry weight) in clayey silt, but are less than 0.4% in sand. Generally, values for TOC increase both toward the west in the Sound and from the shallow margins to the deeper parts of the basin floor. Our data also suggest that TOC concentrations can vary seasonally.

  8. The value of retrofitting carbon-saving measures into fuel poor social housing

    International Nuclear Information System (INIS)

    Jenkins, D.P.

    2010-01-01

    With current fuel poverty and carbon-saving policies continuing to miss their targets in the UK, the synergy between the two problems is investigated to highlight an approach that could be mutually beneficial. Focussing on the 550,000 fuel poor socially housed dwellings in the UK, costs of between Pounds 3.9 and Pounds 17.5 bn are estimated as the required capital investment for achieving deep-cut carbon savings (defined as at least 50%) across this section of the housing stock, with a potential total annual carbon saving of 1.7 MtCO 2 . It is assumed that such costs would be largely (or totally) state-funded, though additional private investment could clearly increase the possible carbon savings across this section of the stock. The use of these socially housed fuel poor dwellings as low-carbon exemplars is discussed, and benefits for the private housing sector are postulated. The study also focuses on the problem of installing non-cost effective measures, i.e. technologies that would not currently be encouraged by existing subsidy schemes, but which might be necessary for achieving large carbon-saving targets.

  9. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis.

    Science.gov (United States)

    Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan

    2005-11-11

    Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p total peroxide level and mean oxidative stress index were higher (all p total peroxide level, total antioxidant response and oxidative stress index (p 0.05). Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.

  10. Parametrization consequences of constraining soil organic matter models by total carbon and radiocarbon using long-term field data

    Science.gov (United States)

    Menichetti, Lorenzo; Kätterer, Thomas; Leifeld, Jens

    2016-05-01

    Soil organic carbon (SOC) dynamics result from different interacting processes and controls on spatial scales from sub-aggregate to pedon to the whole ecosystem. These complex dynamics are translated into models as abundant degrees of freedom. This high number of not directly measurable variables and, on the other hand, very limited data at disposal result in equifinality and parameter uncertainty. Carbon radioisotope measurements are a proxy for SOC age both at annual to decadal (bomb peak based) and centennial to millennial timescales (radio decay based), and thus can be used in addition to total organic C for constraining SOC models. By considering this additional information, uncertainties in model structure and parameters may be reduced. To test this hypothesis we studied SOC dynamics and their defining kinetic parameters in the Zürich Organic Fertilization Experiment (ZOFE) experiment, a > 60-year-old controlled cropland experiment in Switzerland, by utilizing SOC and SO14C time series. To represent different processes we applied five model structures, all stemming from a simple mother model (Introductory Carbon Balance Model - ICBM): (I) two decomposing pools, (II) an inert pool added, (III) three decomposing pools, (IV) two decomposing pools with a substrate control feedback on decomposition, (V) as IV but with also an inert pool. These structures were extended to explicitly represent total SOC and 14C pools. The use of different model structures allowed us to explore model structural uncertainty and the impact of 14C on kinetic parameters. We considered parameter uncertainty by calibrating in a formal Bayesian framework. By varying the relative importance of total SOC and SO14C data in the calibration, we could quantify the effect of the information from these two data streams on estimated model parameters. The weighing of the two data streams was crucial for determining model outcomes, and we suggest including it in future modeling efforts whenever SO14C

  11. Grasland Stable Isotope Flux Measurements: Three Isotopomers of Carbon Dioxide Measured by QCL Spectroscopy

    Science.gov (United States)

    Zeeman, M. J.; Tuzson, B.; Eugster, W.; Werner, R. A.; Buchmann, N.; Emmenegger, L.

    2007-12-01

    To improve our understanding of greenhouse gas dynamics of managed ecosystems such as grasslands, we not only need to investigate the effects of management (e.g., grass cuts) and weather events (e.g., rainy days) on carbon dioxide fluxes, but also need to increase the time resolution of our measurements. Thus, for the first time, we assessed respiration and assimilation fluxes with high time resolution (5Hz) stable isotope measurements at an intensively managed farmland in Switzerland (Chamau, 400m ASL). Two different methods were used to quantify fluxes of carbon dioxide and associated fluxes of stable carbon isotopes: (1) the flux gradient method, and (2) the eddy covariance method. During a week long intensive measurement campaign, we (1) measured mixing ratios of carbon dioxide isotopomers (12C16O2, 12C16O18O, 13C16O2) with a Quantum Cascade Laser (QCL, Aerodyne Inc.) spectroscope and (2) collected air samples for isotope analyses (13C/12C) and (18O/16O) of carbon dioxide by Isotope Ratio Mass Spectrometry (IRMS, Finnigan) every two hours, concurrently along a height profile (z = 0.05; 0.10; 0.31; 2.15m). In the following week, the QCL setup was used for closed-path eddy covariance flux measurement of the carbon dioxide isotopomers, with the air inlet located next to an open-path Infra Red Gas Analyzers (IRGA, LiCor 7500) used simultaneously for carbon dioxide measurements. During this second week, an area of grass inside the footprint was cut and harvested after several days. The first results of in-field continuous QCL measurements of carbon dioxide mixing ratios and their stable isotopic ratios show good agreement with IRGA measurements and isotope analysis of flask samples by IRMS. Thus, QCL spectroscopy is a very promising tool for stable isotope flux investigations.

  12. Effect of selected calculation routines and dissociation constants on the determination of total carbon dioxide in seawater

    NARCIS (Netherlands)

    Stoll, M.H.C.; Rommets, J.W.; Baar, H.J.W. de

    1993-01-01

    During the 1989 and 1990 JGOFS North Atlantic Pilot Study a comparison was made between the Coulometric and the acid titration method for determination of total carbon dioxide (TCO2) in seawater. TCO2 and alkalinity have been calculated from acid titration using either the modified Gran plot or the

  13. Long-term influence of alternative forest management treatments on total ecosystem and wood product carbon storage

    Science.gov (United States)

    Joshua J. Puhlick; Aaron R. Weiskittel; Ivan J. Fernandez; Shawn Fraver; Laura S. Kenefic; Robert S. Seymour; Randall K. Kolka; Lindsey E. Rustad; John C. Brissette

    2016-01-01

    Developing strategies for reducing atmospheric CO2 is one of the foremost challenges facing natural resource professionals today. The goal of this study was to evaluate total ecosystem and harvested wood product carbon (C) stocks among alternative forest management treatments (selection cutting, shelterwood cutting, commercial clearcutting, and...

  14. Spatiotemporal distribution and national measurement of the global carbonate carbon sink.

    Science.gov (United States)

    Li, Huiwen; Wang, Shijie; Bai, Xiaoyong; Luo, Weijun; Tang, Hong; Cao, Yue; Wu, Luhua; Chen, Fei; Li, Qin; Zeng, Cheng; Wang, Mingming

    2018-06-21

    The magnitudes, spatial distributions and contributions to global carbon budget of the global carbonate carbon sink (CCS) still remain uncertain, allowing the problem of national measurement of CCS remain unresolved which will directly influence the fairness of global carbon markets and emission trading. Here, based on high spatiotemporal resolution ecological, meteorological raster data and chemical field monitoring data, combining highly reliable machine learning algorithm with the thermodynamic dissolution equilibrium model, we estimated the new CCS of 0.89 ± 0.23 petagrams of carbon per year (Pg C yr -1 ), amounting to 74.50% of global net forest sink and accounting for 28.75% of terrestrial sinks or 46.81% of the missing sink. Our measurement for 142 nations of CCS showed that Russia, Canada, China and the USA contribute over half of the global CCS. We also presented the first global fluxes maps of the CCS with spatial resolution of 0.05°, exhibiting two peaks in equatorial regions (10°S to 10°N) and low latitudes (10°N to 35°N) in Northern Hemisphere. By contrast, there are no peaks in Southern Hemisphere. The greatest average carbon sink flux (CCSF), i.e., 2.12 tC ha -1  yr -1 , for 2000 to 2014 was contributed by tropical rainforest climate near the equator, and the smallest average CCSF was presented in tropical arid zones, showing a magnitude of 0.26 tC ha -1  yr -1 . This research estimated the magnitudes, spatial distributions, variations and contributions to the global carbon budget of the CCS in a higher spatiotemporal representativeness and expandability way, which, via multiple mechanisms, introduced an important sink in the terrestrial carbon sink system and the global missing sink and that can help us further reveal and support our understanding of global rock weathering carbon sequestration, terrestrial carbon sink system and global carbon cycle dynamics which make our understanding of global change more comprehensive

  15. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis

    Directory of Open Access Journals (Sweden)

    Sarifakiogullari Serpil

    2005-11-01

    Full Text Available Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalcoholic steatohepatitis and 22 healthy controls were enrolled. Total antioxidant response and total peroxide level measurements were done in all participants. The ratio percentage of total peroxide level to total antioxidant response was regarded as oxidative stress index. Results Total antioxidant response of subjects with nonalcoholic steatohepatitis was significantly lower than controls (p In subjects with nonalcoholic steatohepatitis, fibrosis score was significantly correlated with total peroxide level, total antioxidant response and oxidative stress index (p 0.05. Conclusion Nonalcoholic steatohepatitis is associated with increased oxidant capacity, especially in the presence of liver fibrosis. The novel automated assay is a reliable and easily applicable method for total plasma antioxidant response measurement in nonalcoholic steatohepatitis.

  16. Building-Related Symptoms among Office Employees Associated with Indoor Carbon Dioxide and Total Volatile Organic Compounds

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2015-05-01

    Full Text Available This study investigated whether sick building syndrome (SBS complaints among office workers were associated with the indoor air quality. With informed consent, 417 employees in 87 office rooms of eight high-rise buildings completed a self-reported questionnaire for symptoms experienced at work during the past month. Carbon dioxide (CO2, temperature, humidity and total volatile organic compounds (TVOCs in each office were simultaneously measured for eight office hours using portable monitors. Time-averaged workday difference between the indoor and the outdoor CO2 concentrations (dCO2 was calculated as a surrogate measure of ventilation efficiency for each office unit. The prevalence rates of SBS were 22.5% for eye syndrome, 15.3% for upper respiratory and 25.4% for non-specific syndromes. Tiredness (20.9%, difficulty in concentrating (14.6%, eye dryness (18.7% were also common complaints. The generalized estimating equations multivariate logistic regression analyses showed that adjusted odds ratios (aORs and 95% confidence interval (CI per 100 ppm increase in dCO2 were significantly associated with dry throat (1.10, 95% CI = (1.00–1.22, tiredness (1.16, 95% CI = (1.04–1.29 and dizziness (1.22, 95% CI = (1.08–1.37. The ORs for per 100 ppb increases in TVOCs were also associated with upper respiratory symptoms (1.06, 95% CI = (1.04–1.07, dry throat (1.06, 95% CI = (1.03–1.09 and irritability (1.02, 95% CI = (1.01–1.04. In conclusion, the association between some SBS symptoms and the exposure to CO2 and total VOCs are moderate but may be independently significant.

  17. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  18. To Measure Probable Physical Changes On The Earth During Total Solar Eclipse Using Geophysical Methods

    International Nuclear Information System (INIS)

    Gocmen, C.

    2007-01-01

    When the total solar eclipse came into question, people connected the eclipse with the earthquake dated 17.08.1999. We thought if any physical parameters change during total solar eclipse on the earth, we could measure this changing and we did the project 'To Measure Probable Physical Changes On The Earth During Total Solar Eclipse Using Geophysical Methods' We did gravity, magnetic and self-potential measurements at Konya and Ankara during total solar eclipse (29, March, 2006) and the day before eclipse and the day after eclipse. The measurements went on three days continuously twenty-four hours at Konya and daytime in Ankara. Bogazici University Kandilli Observatory gave us magnetic values in Istanbul and we compare the values with our magnetic values. Turkish State Meteorological Service sent us temperature and air pressure observations during three days, in Konya and Ankara. We interpreted all of them

  19. Total gamma activity measurements for determining the radioactivity of residual materials from nuclear power stations

    International Nuclear Information System (INIS)

    Auler, I.; Meyer, M.; Stickelmann, J.

    1995-01-01

    Large amounts of residual materials from retrofitting measures and from decommissioning of nuclear power stations shows such a weak level of radioactivity that they could be released after decision measurements. Expenses incurred with complex geometry cannot be taken with common methods. NIS developed a Release Measurement Facility (RMF) based on total gamma activity measurements especially for these kind of residual materials. The RMF has been applied for decision measurements in different nuclear power plants. Altogether about 2,000 Mg of various types of materials have been measured up to now. More than 90 % of these materials could be released 0 without any restriction after decision measurements

  20. Total antioxidants in plasma of hemodialysed patients and healthy controls measured by two commercial assays

    OpenAIRE

    Ruskovska, Tatjana; Jansen, Eugene

    2012-01-01

    Introduction: As a result of an increased interest in oxidative stress research, in both basic and clinical studies, numerous commercial test kits became available. The aim of this study was to evaluate the results for total antioxidants measured by two commercial assays in a complex clinical condition such as single hemodialysis session in patients on chronic hemodialysis treatment, in comparison to healthy controls. Methods: The level of plasma total antioxidants was measured by BAP ...

  1. PAMELA measurements of the boron and carbon spectra

    International Nuclear Information System (INIS)

    Mori, N; Adriani, O; Bongi, M; Barbarino, G C; Bazilevskaya, G A; Bellotti, R; Bruno, A; Boezio, M; Bonvicini, V; Carbone, R; Bogomolov, E A; Bottai, S; Cafagna, F; Campana, D; Carlson, P; Casolino, M; De Donato, C; De Santis, C; De Simone, N; Castellini, G

    2015-01-01

    The satellite-borne PAMELA experiment is aimed at precision measurements of the charged light component of the cosmic-ray spectrum, with a particular focus on antimatter. It consists of a magnetic spectrometer, a time-of-flight system, an electromagnetic calorimeter with a tail catcher scintillating layer, an anticoincidence system and a neutron detector. PAMELA has measured the absolute fluxes of boron and carbon and the B/C ratio, which plays a central role in galactic propagation studies in order to derive the injection spectra at sources from measurements at Earth. In this paper, the data analysis techniques and the final results are presented. (paper)

  2. Measurement of organic carbon stable isotope composition of different soil types by EA-IRMS system

    International Nuclear Information System (INIS)

    Qi Biao; Ding Lingling; Cui Jiehua; Wang Yanhong

    2009-01-01

    Element analyzer-isotope ratio mass spectrometers (EA-IRMS) is a rapid and precise method for measuring stable carbon isotope. Pure CO 2 reference gas was calibrated via international standard-Urea, and the δ 13 C us PDB value of pure CO 2 is (-29.523 ± 0.0181)%. Stability and linearity of the EA-IRMS system, precision of δ 13 C measurement for samples were tested through experimental comparison. Moreover, determination method of organic carbon stable isotope in soil was based on the system. The EA-IRMS system had well linearity when ion intensity ranged from 1.0 to 7.0V, and it excelled the total linearity when the ion intensity was from 1.5 to 5.0V, and the accurate result of δ 13 C for sample analysis could be obtained with precision of 0.015%. If carbon content in sample is more than 5μg, the requirement for analyzing accurate result of δ 13 C could be achieved. The organic carbon stable isotope was measured in 18 different types soil samples, the average natural abundance of 13 C was 1.082%, and the organic carbon stable isotope composition was significantly different among different type soils. (authors)

  3. Measurement of Total Free Iron in Soils by H2S Chemisorption and Comparison with the Citrate Bicarbonate Dithionite Method

    Directory of Open Access Journals (Sweden)

    Shui-Sheng Fan

    2016-01-01

    Full Text Available Free iron is one of the major analytical items for soil basic properties. It is also an important indicator for understanding the genesis of soil, soil classification, and soil distribution behavior. In this study, an alternative analytical method (chemisorption based on thermodynamic knowledge was proposed for measurement of total free iron oxides in soils. Several representative soil samples belonging to alfisols, ultisols, inceptisols, and entisols were collected from Taiwan and tested by the chemisorption, and the estimated total free iron oxides were compared with those measured from the traditional citrate bicarbonate dithionite (CBD method. Experimental results showed that the optimal operating temperature was found to be at 773 K and the carbon monoxide (CO is the best gaseous reagent to promote the formation of FeS. The estimated total free iron oxides for soil samples determined from the chemisorption in the presence of CO were very close to those from the CBD technique. The result of regression indicates that the estimated total free iron is strongly correlated with the CBD-Fe content (R2=0.999 in the presence of CO.

  4. Neutron total cross section measurements of gold and tantalum at the nELBE photoneutron source

    CERN Document Server

    Hannaske, Roland; Beyer, Roland; Junghans, Arnd; Bemmerer, Daniel; Birgersson, Evert; Ferrari, Anna; Grosse, Eckart; Kempe, Mathias; Kögler, Toni; Marta, Michele; Massarczyk, Ralph; Matic, Andrija; Schramm, Georg; Schwengner, Ronald; Wagner, Andreas

    2014-01-01

    Neutron total cross sections of 197 Au and nat Ta have been measured at the nELBE photoneutron source in the energy range from 0.1 - 10 MeV with a statistical uncertainty of up to 2 % and a total systematic uncertainty of 1 %. This facility is optimized for the fast neutron energy range and combines an excellent t ime structure of the neutron pulses (electron bunch width 5 ps) with a short flight path of 7 m. Because of the low instantaneous neutron flux transmission measurements of neutron total cross sections are possible, that exhibit very different beam and back ground conditions than found at other neutron sources.

  5. 1979-1999 satellite total ozone column measurements over West Africa

    Directory of Open Access Journals (Sweden)

    P. Di Carlo

    2000-06-01

    Full Text Available Total Ozone Mapping Spectrometer (TOMS instruments have been flown on NASA/GSFC satellites for over 20 years. They provide near real-time ozone data for Atmospheric Science Research. As part of preliminary efforts aimed to develop a Lidar station in Nigeria for monitoring the atmospheric ozone and aerosol levels, the monthly mean TOMS total column ozone measurements between 1979 to 1999 have been analysed. The trends of the total column ozone showed a spatial and temporal variation with signs of the Quasi Biennial Oscillation (QBO during the 20-year study period. The values of the TOMS total ozone column, over Nigeria (4-14°N is within the range of 230-280 Dobson Units, this is consistent with total ozone column data, measured since April 1993 with a Dobson Spectrophotometer at Lagos (3°21¢E, 6°33¢N, Nigeria.

  6. The Future of Carbon Monoxide Measurements from Space

    Science.gov (United States)

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  7. [Dynamics of total organic carbon (TOC) in hydrological processes in coniferous and broad-leaved mixed forest of Dinghushan].

    Science.gov (United States)

    Yin, Guangcai; Zhou, Guoyi; Zhang, Deqiang; Wang, Xu; Chu, Guowei; Liu, Yan

    2005-09-01

    The total flux and concentration of total organic carbon (TOC) in hydrological processes in coniferous and broad-leaved mixed forest of Dinghushan were measured from July 2002 to July 2003. The results showed that the TOC input by precipitation was 41.80 kg x hm(-2) x yr(-1), while its output by surface runoff and groundwater (soil solution at 50 cm depth) was 17.54 and 1.80 kg x hm(-2) x yr(-1), respectively. The difference between input and output was 22.46 kg x hm(-2) x yr(-1), indicating that the ecosystem TOC was in positive balance. The monthly variation of TOC flux in hydrological processes was very similar to that in precipitation. The mean TOC concentration in precipitation was 3.64 mg x L(-1), while that in throughfall and stemflow increased 6.10 and 7.39 times after rain passed through the tree canopies and barks. The mean TOC concentration in surface runoff and in soil solution at 25 and 50 cm depths was 12.72, 7.905 and 3.06 mg x L(-1), respectively. The monthly TOC concentration in throughfall and stemflow had a similar changing tendency, showing an increase at the beginning of growth season (March), a decrease after September, and a little increase in December. The TOC concentration in runoff was much higher during high precipitation months. No obvious monthly variation was observed in soil solution TOC concentration (25 and 50 cm below the surface). Stemflow TOC concentration differed greatly between different tree species. The TOC concentration in precipitation, throughfall, and soil solution (25 and 50 cm depths) decreased with increasing precipitation, and no significant relationship existed between the TOC concentrations in stemflow, surface runoff and precipitation. The TOC concentrations in the hydrological processes fluctuated with precipitation intensity, except for that in stemflow and soil solutions.

  8. New neutron capture and total cross section measurements on 88Sr and their impact on s-process nucleosynthesis

    International Nuclear Information System (INIS)

    Koehler, P.E.; Spencer, R.R.; Guber, K.H.

    1998-01-01

    The authors have made new and improved measurements of the neutron capture and total cross sections of 88 Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the 88 Sr(n,γ) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact

  9. Total uncertainty of low velocity thermal anemometers for measurement of indoor air movements

    DEFF Research Database (Denmark)

    Jørgensen, F.; Popiolek, Z.; Melikov, Arsen Krikor

    2004-01-01

    For a specific thermal anemometer with omnidirectional velocity sensor the expanded total uncertainty in measured mean velocity Û(Vmean) and the expanded total uncertainty in measured turbulence intensity Û(Tu) due to different error sources are estimated. The values are based on a previously...... developed mathematical model of the anemometer in combination with a large database of representative room flows measured with a 3-D Laser Doppler anemometer (LDA). A direct comparison between measurements with a thermal anemometer and a 3-D LDA in flows of varying velocity and turbulence intensity shows...... good agreement not only between the two instruments but also between the thermal anemometer and its mathematical model. The differences in the measurements performed with the two instruments are all well within the measurement uncertainty of both anemometers....

  10. Side-by-side comparison of techniques for analyzing organic acids, total organic carbon, and anions. Final report

    International Nuclear Information System (INIS)

    Byers, W.A.; Richards, J.; Silva, H.; Miller, M.R.; Palino, G.F.; Wall, P.S.

    1986-09-01

    The objective of this project was to compare the organic acids sampling and analysis methods of Westinghouse and NWT Corporation. Sampling was performed at three sites, chosen to represent units with high, intermediate and low levels of organic contamination. To check the precision of each method, concurrent sampling was employed. To check the accuracy of each method, additions of standard organic solutions were made at one of the sites. Inorganic anions were also analyzed at each site by each contractor. Theoretical values of cation conductivity were calculated from organic and inorganic analytical data and compared to values measured onsite at the time of sampling. Total organic carbon (TOC) analyses were performed to evaluate different instruments and sampling techniques, as well as provide additional information on the relationship between TOC and organic acids concentrations. It was concluded that either of the organic acid sampling/analysis techniques used by the contractors can produce reliable results. TOC samples lose organics content with storage time and should be analyzed no later than one week after they are taken; if at all possible, they should be stored in a refrigerated condition. State-of-the art techniques for TOC sampling and analysis can produce results varying by 20 to 50 ppB for levels in the range of 50 to 120 ppB; any proposed limits for TOC should be reviewed in that light. Results of anion analyses are quite sensitive to sampling and analytical techniques. Reasonable agreement between calculated and measured values of cation conductivity suggests that both contractors had accurately determined all major anionic species

  11. Radiologic total lung capacity measurement. Development and evaluation of a computer-based system

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, G.W.; Mazzeo, J.; Borgstrom, M.; Hunter, T.B.; Newell, J.D.; Bjelland, J.C.

    1986-11-01

    The development of a computer-based radiologic total lung capacity (TLC) measurement system designed to be used by non-physician personnel is detailed. Four operators tested the reliability and validity of the system by measuring inspiratory PA and lateral pediatric chest radiographs with a Graf spark pen interfaced to a DEC VAX 11/780 computer. First results suggest that the ultimate goal of developing an accurate and easy to use TLC measurement system for non-physician personnel is attainable.

  12. Comparative study of radiometric and calorimetric methods for total hemispherical emissivity measurements

    Science.gov (United States)

    Monchau, Jean-Pierre; Hameury, Jacques; Ausset, Patrick; Hay, Bruno; Ibos, Laurent; Candau, Yves

    2018-05-01

    Accurate knowledge of infrared emissivity is important in applications such as surface temperature measurements by infrared thermography or thermal balance for building walls. A comparison of total hemispherical emissivity measurement was performed by two laboratories: the Laboratoire National de Métrologie et d'Essais (LNE) and the Centre d'Études et de Recherche en Thermique, Environnement et Systèmes (CERTES). Both laboratories performed emissivity measurements on four samples, chosen to cover a large range of emissivity values and angular reflectance behaviors. The samples were polished aluminum (highly specular, low emissivity), bulk PVC (slightly specular, high emissivity), sandblasted aluminum (diffuse surface, medium emissivity), and aluminum paint (slightly specular surface, medium emissivity). Results obtained using five measurement techniques were compared. LNE used a calorimetric method for direct total hemispherical emissivity measurement [1], an absolute reflectometric measurement method [2], and a relative reflectometric measurement method. CERTES used two total hemispherical directional reflectometric measurement methods [3, 4]. For indirect techniques by reflectance measurements, the total hemispherical emissivity values were calculated from directional hemispherical reflectance measurement results using spectral integration when required and directional to hemispherical extrapolation. Results were compared, taking into account measurement uncertainties; an added uncertainty was introduced to account for heterogeneity over the surfaces of the samples and between samples. All techniques gave large relative uncertainties for a low emissive and very specular material (polished aluminum), and results were quite scattered. All the indirect techniques by reflectance measurement gave results within ±0.01 for a high emissivity material. A commercial aluminum paint appears to be a good candidate for producing samples with medium level of emissivity

  13. Evaluating the capabilities of portable black carbon monitors and photometers for measuring airborne carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Naomi; Ogura, Isamu, E-mail: i-ogura@aist.go.jp; Kotake, Mari; Kishimoto, Atsuo; Honda, Kazumasa [Technology Research Association for Single Wall Carbon Nanotubes (TASC) (Japan)

    2013-11-15

    For daily monitoring of occupational exposure to aerosolized carbon nanotubes (CNTs) where CNTs are manufactured and handled, inexpensive real-time measuring methods are preferable. In this study, we evaluated the capabilities of a portable black carbon monitor (BCM; also called an aethalometer) and a light-scattering aerosol photometer in detecting airborne CNTs. The responses of these instruments to airborne CNTs, aerosolized through vortex shaking, were evaluated by comparing the measurements of CNT mass concentrations made by these instruments to those determined through thermal carbon analysis. Results showed that their raw readings underestimated CNT mass concentrations in most cases. Their sensitivities depended on the type of CNTs and decreased with the particle sizes of aerosolized CNT clumps. We also found that the sensitivity of the BCM tended to substantially decrease with increasing filter load, even before the point at which the filter should be replaced as recommended by the manufacturer, which could be attributed to a clean environmental condition (i.e., the absence of ubiquitous light-scattering material). As an example of the use of these instruments for measuring airborne CNTs in the presence of background aerosols, a CNT-handling simulation was also conducted. Although both the BCM and the photometer could detect CNT emissions, the BCM was more sensitive to the detection of emitted CNTs in the presence of background aerosols. The correction factors obtained from the response evaluations could enhance the measurement accuracy of these instruments, which will be helpful for the daily monitoring of CNTs at workplaces.

  14. Evaluating the capabilities of portable black carbon monitors and photometers for measuring airborne carbon nanotubes

    International Nuclear Information System (INIS)

    Hashimoto, Naomi; Ogura, Isamu; Kotake, Mari; Kishimoto, Atsuo; Honda, Kazumasa

    2013-01-01

    For daily monitoring of occupational exposure to aerosolized carbon nanotubes (CNTs) where CNTs are manufactured and handled, inexpensive real-time measuring methods are preferable. In this study, we evaluated the capabilities of a portable black carbon monitor (BCM; also called an aethalometer) and a light-scattering aerosol photometer in detecting airborne CNTs. The responses of these instruments to airborne CNTs, aerosolized through vortex shaking, were evaluated by comparing the measurements of CNT mass concentrations made by these instruments to those determined through thermal carbon analysis. Results showed that their raw readings underestimated CNT mass concentrations in most cases. Their sensitivities depended on the type of CNTs and decreased with the particle sizes of aerosolized CNT clumps. We also found that the sensitivity of the BCM tended to substantially decrease with increasing filter load, even before the point at which the filter should be replaced as recommended by the manufacturer, which could be attributed to a clean environmental condition (i.e., the absence of ubiquitous light-scattering material). As an example of the use of these instruments for measuring airborne CNTs in the presence of background aerosols, a CNT-handling simulation was also conducted. Although both the BCM and the photometer could detect CNT emissions, the BCM was more sensitive to the detection of emitted CNTs in the presence of background aerosols. The correction factors obtained from the response evaluations could enhance the measurement accuracy of these instruments, which will be helpful for the daily monitoring of CNTs at workplaces

  15. Impact of total organic carbon (in sediments) and dissolved organic carbon (in overlying water column) on Hg sequestration by coastal sediments from the central east coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Chakrabortya, P.; Sharma, B.M.; Babu, P.V.R.; Yao, K.M.; Jaychandran, S.

    , 1991; Liu et al., 2006; Tack and Verloo, 1995). Mercury accumulates in sediment globally from many physical, chemical, biological, geological and anthropogenic environmental processes. Thus, sediment can be a good indicator of water quality of a...-Black method (Schumacher, 2002). This method has been widely used for the determination of total organic carbon in the soil and sediments. 3.0 Results and discussion The general description and texture analysis of the studied sediments are presented...

  16. Lebanese household carbon footprint: Measurements, analysis and challenges

    Science.gov (United States)

    Nasr, Rawad; Tall, Ibrahim; Nachabe, Nour; Chaaban, Farid

    2016-07-01

    The main purpose of this paper is to estimate the carbon footprint of a typical Lebanese household, and compare the results with international standards and trends. The estimation of this footprint will reflect the impact of the daily Lebanese household activities on the environment in terms of carbon dioxide emissions. The method used in estimating the carbon emissions is based on gathering the primary footprints from various household activities. Another proposed method that provides more accurate results is the estimation of emissions based on secondary footprint, which reflects the total emissions not only from the regular activities but also from a lifecycle perspective. Practical and feasible solutions were proposed to help reduce the amount of C02 emissions per household. This would lead to a better air quality, money savings, greenhouse gases emissions reduction and would ensure the sustainability and prosperity of future generations. A detailed survey was conducted in which the questions were focused mainly on energy, food, and transportation issues. The fourteen questions were addressed to one hundred families in different Lebanese regions coming from different social and economic backgrounds. This diversity would constitute a reflective sample of the actual Lebanese society, allowing us to extrapolate the gathered results on a national level.

  17. Biogenic Methane Generation Potential in the Eastern Nankai Trough, Japan: Effect of Reaction Temperature and Total Organic Carbon

    Science.gov (United States)

    Aung, T. T.; Fujii, T.; Amo, M.; Suzuki, K.

    2017-12-01

    Understanding potential of methane flux from the Pleistocene fore-arc basin filled turbiditic sedimentary formation along the eastern Nankai Trough is important in the quantitative assessment of gas hydrate resources. We considered generated methane could exist in sedimentary basin in the forms of three major components, and those are methane in methane hydrate, free gas and methane dissolved in water. Generation of biomethane strongly depends on microbe activity and microbes in turn survive in diverse range of temperature, salinity and pH. This study aims to understand effect of reaction temperature and total organic carbon on generation of biomethane and its components. Biomarker analysis and cultural experiment results of the core samples from the eastern Nankai Trough reveal that methane generation rate gets peak at various temperature ranging12.5°to 35°. Simulation study of biomethane generation was made using commercial basin scale simulator, PetroMod, with different reaction temperature and total organic carbon to predict how these effect on generation of biomethane. Reaction model is set by Gaussian distribution with constant hydrogen index and standard deviation of 1. Series of simulation cases with peak reaction temperature ranging 12.5°to 35° and total organic carbon of 0.6% to 3% were conducted and analyzed. Simulation results show that linear decrease in generation potential while increasing reaction temperature. But decreasing amount becomes larger in the model with higher total organic carbon. At higher reaction temperatures, >30°, extremely low generation potential was found. This is due to the fact that the source formation modeled is less than 1 km in thickness and most of formation do not reach temperature more than 30°. In terms of the components, methane in methane hydrate and free methane increase with increasing TOC. Drastic increase in free methane was observed in the model with 3% of TOC. Methane amount dissolved in water shows almost

  18. Black Carbon Measurements From Ireland's Transboundary Network (TXB)

    Science.gov (United States)

    Spohn, T. K.; Martin, D.; O'Dowd, C. D. D.

    2017-12-01

    Black Carbon (BC) is carbonaceous aerosol formed by incomplete fossil fuel combustion. Named for its light absorbing properties, it acts to trap heat in the atmosphere, thus behaving like a greenhouse gas, and is considered a strong, short-lived climate forcer by the International Panel on Climate Change (IPCC). Carbonaceous aerosols from biomass burning (BB) such as forest fires and residential wood burning, also known as brown carbon, affect the ultra violet (UV) light absorption in the atmosphere as well. In 2016 a three node black carbon monitoring network was established in Ireland as part of a Transboundary Monitoring Network (TXB). The three sites (Mace Head, Malin Head, and Carnsore Point) are coastal locations on opposing sides of the country, and offer the opportunity to assess typical northern hemispheric background concentrations as well national and European pollution events. The instruments deployed in this network (Magee Scientific AE33) facilitate elimination of the changes in response due to `aerosol loading' effects; and a real-time calculation of the `loading compensation' parameter which offers insights into aerosol optical properties. Additionally, these instruments have an inbuilt algorithm, which estimates the difference in absorption in the ultraviolet wavelengths (mostly by brown carbon) and the near infrared wavelengths (only by black carbon).Presented here are the first results of the BC measurements from the three Irish stations, including instrument validation, seasonal variation as well as local, regional, and transboundary influences based on air mass trajectories as well as concurrent in-situ observations (meteorological parameters, particle number, and aerosol composition). A comparison of the instrumental algorithm to off-line sensitivity calculations will also be made to assess the contribution of biomass burning to BC pollution events.

  19. Measurement of the total antioxidant response using a novel automated method in subjects with nonalcoholic steatohepatitis

    OpenAIRE

    Horoz, Mehmet; Bolukbas, Cengiz; Bolukbas, Fusun F; Sabuncu, Tevfik; Aslan, Mehmet; Sarifakiogullari, Serpil; Gunaydin, Necla; Erel, Ozcan

    2005-01-01

    Abstract Background Oxidative stress, an increase in oxidants and/or a decrease in antioxidant capacity, is one of the potential biochemical mechanisms involved in the pathogenesis of nonalcoholic steatohepatitis. We aimed to investigate the total antioxidant response using a novel automated method in nonalcoholic steatohepatitis subjects. As a reciprocal measure, we also aimed to determine total peroxide level in the same plasma samples. Methods Twenty-two subjects with biopsy proven nonalco...

  20. Development of an immunoradiometric method for the measurement of total PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.; Korde, A.; Bapat, K.; Shukla, A.; Pillai, M.R.A.

    1999-01-01

    Development of an IRMA for total-PSA was taken up in our laboratories (Isotope Division, Bhabha Atomic Research Centre, Mumbai, India) and efforts were made to obtain monoclonals for PSA at our laboratory. Following the guidelines laid at the first meeting of this CRP we have used the reagents supplied by the Agency as well as our inhouse reagents, and attempted to develop assay procedures for measuring total-PSA in human sera

  1. Tropical intercontinental optical measurement network of aerosol, precipitable water and total column ozone

    Science.gov (United States)

    Holben, B. N.; Tanre, D.; Reagan, J. A.; Eck, T. F.; Setzer, A.; Kaufman, Y. A.; Vermote, E.; Vassiliou, G. D.; Lavenu, F.

    1992-01-01

    A new generation of automatic sunphotometers is used to systematically monitor clear sky total column aerosol concentration and optical properties, precipitable water and total column ozone diurnally and annually in West Africa and South America. The instruments are designed to measure direct beam sun, solar aureole and sky radiances in nine narrow spectral bands from the UV to the near infrared on an hourly basis. The instrumentation and the algorithms required to reduce the data for subsequent analysis are described.

  2. Uncertainty of forest carbon stock changes. Implications to the total uncertainty of GHG inventory of Finland

    International Nuclear Information System (INIS)

    Monni, S.; Savolainen, I.; Peltoniemi, M.; Lehtonen, A.; Makipaa, R.; Palosuo, T.

    2007-01-01

    Uncertainty analysis facilitates identification of the most important categories affecting greenhouse gas (GHG) inventory uncertainty and helps in prioritisation of the efforts needed for development of the inventory. This paper presents an uncertainty analysis of GHG emissions of all Kyoto sectors and gases for Finland consolidated with estimates of emissions/removals from LULUCF categories. In Finland, net GHG emissions in 2003 were around 69 Tg (±15 Tg) CO2 equivalents. The uncertainties in forest carbon sink estimates in 2003 were larger than in most other emission categories, but of the same order of magnitude as in carbon stock change estimates in other land use, land-use change and forestry (LULUCF) categories, and in N2O emissions from agricultural soils. Uncertainties in sink estimates of 1990 were lower, due to better availability of data. Results of this study indicate that inclusion of the forest carbon sink to GHG inventories reported to the UNFCCC increases uncertainties in net emissions notably. However, the decrease in precision is accompanied by an increase in the accuracy of the overall net GHG emissions due to improved completeness of the inventory. The results of this study can be utilised when planning future GHG mitigation protocols and emission trading schemes and when analysing environmental benefits of climate conventions

  3. Measurement of population inversions and gain in carbon fiber plasmas

    International Nuclear Information System (INIS)

    Milchberg, H.; Skinner, C.H.; Suckewer, S.; Voorhees, D.

    1985-10-01

    A CO 2 laser (approx.0.5 kJ energy, 70 nsec pulse width) was focussed onto the end of an axially oriented, thick (35 to 350 μ) carbon fiber with or without a magnetic field present along the laser-fiber axis. We present evidence for axial-to-transverse enhancement of the CVI 182A (n = 3 → 2) transition, which is correlated with the appearance of a population inversion between levels n = 3 and 2. For the B = 0 kG, zero field case, the maximum gain-length product of kl approx. =3 (k approx. =6 cm -1 ) was measured for a carbon fiber coated with a thin layer of aluminum (for additional radiation cooling). The results are interpreted in terms of fast recombination due mostly to thermal conduction from the plasma to the cold fiber core

  4. Carbon dioxide effects research and assessment program. Measurement of changes in terrestrial carbon using remote sensing

    Energy Technology Data Exchange (ETDEWEB)

    Woodwell, G M [ed.

    1980-09-01

    Changes in the area of forests as well as changes in the storage of carbon within forest stands have large potential effects on atmospheric CO/sub 2/. This conference addressed the challenge of measuring changes in the area of forests globally through use of satellite remote sensing. The conclusion of the approximately seventy participants from around the world was that a program based on LANDSAT imagery supplemented by aerial photography is both possible and appropriate.

  5. Comparison of biuret and refractometry methods for the serum total proteins measurement in ruminants.

    Science.gov (United States)

    Katsoulos, Panagiotis D; Athanasiou, Labrini V; Karatzia, Maria A; Giadinis, Nektarios; Karatzias, Harilaos; Boscos, Constantin; Polizopoulou, Zoe S

    2017-12-01

    Determination of serum total protein concentration is commonly performed by the biuret method. Refractometric measurement is a faster and less expensive alternative but its accuracy has not been determined in ruminants. The purpose of the study was to compare the serum total protein concentrations in cattle, sheep, and goats measured by the biuret method with those obtained by refractometry. Serum total protein concentration was determined in 120 cattle, 67 sheep, and 58 goat blood samples refractometrically and with the biuret method. The data were analyzed with a paired samples t-test, and Passing and Bablok regression equations and Bland and Altman plots were generated. There was a strong linear relationship between the total protein values determined with the refractometer and the biuret method in cattle, sheep, and goats. The statistical accuracy, which represents a bias correction factor that measures the deviation of the best-fit line from the 45° line through the origin, was 90.63% for cattle, 93.05% for sheep, and 91.76% for goats. The mean protein values determined with the refractometer were significantly lower than those measured with the biuret method in cattle and goats (P  .05). The evaluated refractometer was sufficiently accurate for the determination of serum total proteins in cattle, sheep, and goats, although it cannot be used interchangeably with the biuret method. The RIs should be corrected for negative bias based on the created equations. © 2017 American Society for Veterinary Clinical Pathology.

  6. Spatial Variation of Soil Organic Carbon and Total Nitrogen in the Coastal Area of Mid-Eastern China.

    Science.gov (United States)

    Xu, Yan; Pu, Lijie; Liao, Qilin; Zhu, Ming; Yu, Xue; Mao, Tianying; Xu, Chenxing

    2017-07-14

    Soils play an important role in sequestrating atmospheric CO₂. Coastal tidal flats have been intensively reclaimed for food security and living spaces worldwide. We aimed to identify the changes of soil organic carbon (SOC) and total nitrogen (TN) following coastal reclamation and their spatial variation in the coastal area of mid-Eastern China to provide information for coastal cropland management. We measured SOC and TN of 463 soil samples in the coastal plain of mid-Eastern China. The results showed that SOC and TN increased highly from the uncultivated coastal tidal flat (2.49 g·kg -1 and 0.21 g·kg -1 , respectively) to the cropland (10.73 g·kg -1 and 1.3 g·kg -1 , respectively). After long-term cultivation, SOC and TN in the old farmland (12.98 g·kg -1 and 1.49 g·kg -1 , respectively) were greater than those in the young farmland (5.76 g·kg -1 and 0.86 g·kg -1 , respectively). The density of SOC in the uncultivated coastal tidal flat, young farmland, and old farmland were 0.68 kg·C·m -2 , 1.52 kg·C·m -2 , and 3.31 kg·C·m -2 , respectively. The density of TN in the uncultivated coastal tidal flat, young farmland and old farmland were 0.05 kg·N·m -2 , 0.23 kg·N·m -2 , and 0.38 kg·N·m -2 , respectively. The C/N (11.17) in the uncultivated coastal tidal flat was highest comparing to that in the young and old farmland due to lower nitrogen. The C/N increased from 6.78 to 8.71 following cultivation. Reclaimed coastal tidal flats had high carbon and nitrogen sequestration potential that not only mitigated the threat of global warming, but also improved soil fertility for crop production. Coastal management of cropland should consider the spatial distribution of SOC and TN to improve ecosystem services of coastal soils.

  7. Chapter 4: Measurements of total beta-activity in the fallout

    International Nuclear Information System (INIS)

    Duggleby, J.C.; Johannessen, J.C.; Kotler, L.H.; Stewart, F.M.

    1974-01-01

    In order to provide information on fresh fission products in fallout reaching Australia from nuclear tests being conducted by France in Polynesia, measurements were made of total beta activity in daily fallout deposition of 25 Australian sampling stations covering a three month period from 25 July to 23 October 1973. The methods employed to measure the radioactivity of the samples are described and the data on total beta-activity, and the calculated external gamma radiation doses from fresh fallout are presented. (R.L.)

  8. Separation of total lipids on human lipoproteins using surfactant-coated multiwalled carbon nanotubes as pseudostationary phase in capillary electrophoresis.

    Science.gov (United States)

    Su, Mei-Yu; Chen, Yen-Yi; Yang, Jian-Ying; Lin, You-Sian; Lin, Yang-Wei; Liu, Mine-Yine

    2014-04-01

    Surfactant-coated multiwalled carbon nanotubes (MWNTs) were used as pseudostationary phase (PSP) in CE to investigate the total lipids of high-density lipoproteins and low-density lipoproteins. To optimize the CE conditions, several experimental factors including carbon nanotube concentration, bile salt concentration, sodium phosphate (PB) concentration, organic modifier concentration and buffer pH value have been examined. In addition, the CE capillary temperature and applied voltage have also been examined. The optimal separation buffer selected was a mixture of 3.2 mg/L MWNT, 50 mM bile salt, 10 mM PB, 20% 1-propanol, pH 9.5. The optimal capillary temperature and applied voltage selected were 50°C and 20 kV, respectively. Phosphatidyl choline (PC) has been used as a model analyte and investigated by the optimal CE method. The linear range for PC was 0.1-3 mg/mL with a correlation coefficient of 0.9934, and the concentration LOD was 0.055 mg/mL. The optimal CE method has been used to characterize the total lipids of high-density lipoprotein and low-density lipoprotein. At absorbance 200 nm, one major peak and two or three minor peaks showed for the total lipids of lipoproteins within 13 minutes. Resolutions of the total lipids were enhanced using surfactant-coated MWNTs as PSPs in the CE separation buffer. However, resolutions of the total lipids were not enhanced using surfactant-coated single-walled carbon nanotubes as PSPs in the CE separation buffer. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Measurement of Neutron Total Cross Sections in Support of the APT Program

    International Nuclear Information System (INIS)

    Abfalterer, W.P.; Haight, R.C.; Morgan, G.L.; Bateman, F.B.; Dietrich, F.S.; Finlay, R.W.

    1998-01-01

    The authors have completed a new set of total cross section measurements of 37 samples spanning the periodic table. The authors employed the same technique as in a previous measurement, with refinements intended to allow measurements on separated isotopes, and with improved systematic error control. The goal of the new measurement was 1% statistical accuracy in 1% energy bins with systematic errors less than 1%. This was achieved for all but the smallest samples, for which the statistical accuracy was as large as 2% in 1% bins

  10. Measurement with total scatter calibrate factor at different depths in the calculation of prescription dose

    International Nuclear Information System (INIS)

    Li Lijun; Zhu Haijun; Zhang Xinzhong; Li Feizhou; Song Hongyu

    2004-01-01

    Objective: To evaluate the method of measurement of total scatter calibrate factor (Sc, p). Methods: To measure the Sc, p at different depths on central axis of 6MV, 15MV photon beams through different ways. Results: It was found that the measured data of Sc, p changed with the different depths to a range of 1% - 7%. Using the direct method, the Sc, p measured depth should be the same as the depth in dose normalization point of the prescription dose. If the Sc, p (fsz, d) was measured at the other depths, it could be obtained indirectly by the calculation formula. Conclusions: The Sc, p in the prescription dose can be obtained either by the direct measure method or the indirect calculation formula. But emphasis should be laid on the proper measure depth. (authors)

  11. Utility of noninvasive transcutaneous measurement of postoperative hemoglobin in total joint arthroplasty patients.

    Science.gov (United States)

    Stoesz, Michael; Wood, Kristin; Clark, Wesley; Kwon, Young-Min; Freiberg, Andrew A

    2014-11-01

    This study prospectively evaluated the clinical utility of a noninvasive transcutaneous device for postoperative hemoglobin measurement in 100 total hip and knee arthroplasty patients. A protocol to measure hemoglobin noninvasively, prior to venipuncture, successfully avoided venipuncture in 73% of patients. In the remaining 27 patients, there were a total of 48 venipunctures performed during the postoperative hospitalization period due to reasons including transcutaneous hemoglobin measurement less than or equal to 9 g/dL (19), inability to obtain a transcutaneous hemoglobin measurement (8), clinical signs of anemia (3), and noncompliance with the study protocol (18). Such screening protocols may provide a convenient and cost-effective alternative to routine venipuncture for identifying patients at risk for blood transfusion after elective joint arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. A simple approach to estimate daily loads of total, refractory, and labile organic carbon from their seasonal loads in a watershed.

    Science.gov (United States)

    Ouyang, Ying; Grace, Johnny M; Zipperer, Wayne C; Hatten, Jeff; Dewey, Janet

    2018-05-22

    Loads of naturally occurring total organic carbons (TOC), refractory organic carbon (ROC), and labile organic carbon (LOC) in streams control the availability of nutrients and the solubility and toxicity of contaminants and affect biological activities through absorption of light and complex metals with production of carcinogenic compounds. Although computer models have become increasingly popular in understanding and management of TOC, ROC, and LOC loads in streams, the usefulness of these models hinges on the availability of daily data for model calibration and validation. Unfortunately, these daily data are usually insufficient and/or unavailable for most watersheds due to a variety of reasons, such as budget and time constraints. A simple approach was developed here to calculate daily loads of TOC, ROC, and LOC in streams based on their seasonal loads. We concluded that the predictions from our approach adequately match field measurements based on statistical comparisons between model calculations and field measurements. Our approach demonstrates that an increase in stream discharge results in increased stream TOC, ROC, and LOC concentrations and loads, although high peak discharge did not necessarily result in high peaks of TOC, ROC, and LOC concentrations and loads. The approach developed herein is a useful tool to convert seasonal loads of TOC, ROC, and LOC into daily loads in the absence of measured daily load data.

  13. Continuous analyzers of hydrogen and carbon in liquid sodium and of hydrocarbon total in protective atmosphere above sodium

    International Nuclear Information System (INIS)

    Pitak, O.; Fresl, M.

    1980-01-01

    The principle is described of a leak detector for detecting water penetration into sodium in a steam generator. The device operates as a diffusion H-meter with an ion pump. Ni or Fe diffusion diaphragm is washed with sodium while diffused hydrogen is pumped and also monitored with the ion pump. Another detector uses the principle of analyzing hydrocarbons in the cover gas above the sodium level. The carrier gas flow for the analyzer divided into measuring and reference parts is passed through a chamber housing the diffusion standard. For measuring carbon content in sodium, the detector analytical part may be completed with a chamber with moisturizing filling for scrubbing gas. Carbon passing through the diffusion Fe diaphragm is scrubbed on the inner wall in the form of CO which is reduced to methane and measured using the detector C-meter. (M.S.)

  14. Total body-calcium measurements: comparison of two delayed-gamma neutron activation facilities

    International Nuclear Information System (INIS)

    Ma, R.; Ellis, K.J.; Shypailo, R.J.; Pierson, R.N. Jr.

    1999-01-01

    This study compares two independently calibrated delayed-gamma neutron activation (DGNA) facilities, one at the Brookhaven National Laboratory (BNL), Upton, New York, and the other at the Children's Nutrition Research Center (CNRC), Houston, Texas that measure total body calcium (TBCa). A set of BNL phantoms was sent to CNRC for neutron activation analysis, and a set of CNRC phantoms was measured at BNL. Both facilities showed high precision (<2%), and the results were in good agreement, within 5%. (author)

  15. The nTOF Total Absorption Calorimeter for neutron capture measurements at CERN

    International Nuclear Information System (INIS)

    Guerrero, C.; Abbondanno, U.; Aerts, G.; Alvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Assimakopoulos, P.; Audouin, L.; Badurek, G.; Baumann, P.; Becvar, F.; Berthoumieux, E.; Calvino, F.; Calviani, M.; Cano-Ott, D.; Capote, R.; Carrapico, C.; Cennini, P.; Chepel, V.

    2009-01-01

    The n T OF Collaboration has built and commissioned a high-performance detector for (n,γ) measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and discuss its overall performance in terms of energy and time resolution, background discrimination, detection efficiency and neutron sensitivity.

  16. Seasonal features of black carbon measured at Syowa Station, Antarctica

    Science.gov (United States)

    Hara, K.; Osada, K.; Yabuki, M.; Shiobara, M.; Yamanouchi, T.

    2015-12-01

    Black carbon (BC) is one of important aerosol constituents because the strong light absorption ability. Low concentrations of aerosols and BC let BC make insignificant contribution to aerosol radiative forcing in the Antarctica at the moment. Because of less or negligible source strength of BC in the Antarctic circle, BC can be used as a tracer of transport from the mid-latitudes. This study aims to understand seasonal feature, transport pathway, and origins of black carbon in the Antarctic coats. Black carbon measurement has been made using 7-wavelength aethalometer at Syowa Station, Antarctica since February, 2005. Mass BC concentrations were estimated from light attenuation by Weingartner's correction procedure (Weingartner et al., 2003) in this study. Detection limit was 0.2 - 0.4 ng/m3 in our measurement conditions (2-hour resolution and flow rate of ca. 10LPM). BC concentrations ranged from near detection limit to 55.7 ng/m3 at Syowa Station, Antarctica during the measurements. No trend has been observed since February, 2005. High BC concentrations were coincident with poleward flow from the mid-latitudes under the storm conditions by cyclone approach, whereas low BC concentrations were found in transport from coastal regions and the Antarctic continent. Considering that outflow from South America and Southern Africa affect remarkably air quality in the Southern Ocean of Atlantic and Indian Ocean sectors, BC at Syowa Station might be originated from biomass burning and human activity on South America and Southern Africa. Seasonal features of BC at Syowa Station shows maximum in September - October and lower in December - April. Spring maximum in September - October was obtained at the other Antarctic stations (Neumayer, Halley, South pole, and Ferraz). Although second maximum was found in January at the other stations, the maximum was not observed at Syowa Station.

  17. The impact of Southwest Airline's contribution to atmospheric Carbon Dioxide and Nitrous Oxide totals

    Science.gov (United States)

    Wilkerson, Cody L.

    Over the last century, aviation has grown to become an economical juggernaut. The industry creates innovation, connects people, and maintains a safety goal unlike any other field. However, as the world becomes more populated with technology and individuals, a general curiosity as to how human activity effects the planet is becoming of greater interest. This study presents what one domestic airline in the United States, Southwest Airlines, contributes to the atmospheric make-up of the planet. Utilizing various sources of quantifiable data, an outcome was reached that shows the amount of Carbon Dioxide and Nitrous Oxide produced by Southwest Airlines from 2002 to 2013. This topic was chosen due to the fact that there are no real quantifiable values of emission statistics from airlines available to the public. Further investigation allowed for Southwest Airlines to be compared to the overall Carbon Dioxide and Nitrous Oxide contributions of the United States for the year 2011. The results showed that with the absence of any set standard on emissions, it is vital that one should be established. The data showed that the current ICAO standard emission values showed a higher level of emissions than when Southwest Airline's fleet was analyzed using their actual fleet mix.

  18. Helium Mass Spectrometer Leak Detection: A Method to Quantify Total Measurement Uncertainty

    Science.gov (United States)

    Mather, Janice L.; Taylor, Shawn C.

    2015-01-01

    In applications where leak rates of components or systems are evaluated against a leak rate requirement, the uncertainty of the measured leak rate must be included in the reported result. However, in the helium mass spectrometer leak detection method, the sensitivity, or resolution, of the instrument is often the only component of the total measurement uncertainty noted when reporting results. To address this shortfall, a measurement uncertainty analysis method was developed that includes the leak detector unit's resolution, repeatability, hysteresis, and drift, along with the uncertainty associated with the calibration standard. In a step-wise process, the method identifies the bias and precision components of the calibration standard, the measurement correction factor (K-factor), and the leak detector unit. Together these individual contributions to error are combined and the total measurement uncertainty is determined using the root-sum-square method. It was found that the precision component contributes more to the total uncertainty than the bias component, but the bias component is not insignificant. For helium mass spectrometer leak rate tests where unit sensitivity alone is not enough, a thorough evaluation of the measurement uncertainty such as the one presented herein should be performed and reported along with the leak rate value.

  19. Metrological traceability of carbon dioxide measurements in atmosphere and seawater

    International Nuclear Information System (INIS)

    Rolle, F; Pessana, E; Sega, M

    2017-01-01

    The accurate determination of gaseous pollutants is fundamental for the monitoring of the trends of these analytes in the environment and the application of the metrological concepts to this field is necessary to assure the reliability of the measurement results. In this work, an overview of the activity carried out at Istituto Nazionale di Ricerca Metrologica to establish the metrological traceability of the measurements of gaseous atmospheric pollutants, in particular of carbon dioxide (CO 2 ), is presented. Two primary methods, the gravimetry and the dynamic dilution, are used for the preparation of reference standards for composition which can be used to calibrate sensors and analytical instrumentation. At present, research is carried out to lower the measurement uncertainties of the primary gas mixtures and to extend their application to the oceanic field. The reason of such investigation is due to the evidence of the changes occurring in seawater carbonate chemistry, connected to the rising level of CO 2 in the atmosphere. The well established activity to assure the metrological traceability of CO 2 in the atmosphere will be applied to the determination of CO 2 in seawater, by developing suitable reference materials for calibration and control of the sensors during their routine use. (paper)

  20. Electrical measurements on submicronic synthetic conductors : carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Langer, L [Unite de Physico-Chimie et de Physique des Materiaux, Univ. Catholique de Louvain, Louvain-la-Neuve (Belgium); Stockman, L [Lab. voor Vaste Stof-Fysika en Magnetisme, Katholieke Univ. Leuven (Belgium); Heremans, J P [Physics Dept., General Motors Research, Warren, MI (United States); Bayot, V [Unite de Physico-Chimie et de Physique des Materiaux, Univ. Catholique de Louvain, Louvain-la-Neuve (Belgium); Olk, C H [Physics Dept., General Motors Research, Warren, MI (United States); Haesendonck, C van [Lab. voor Vaste Stof-Fysika en Magnetisme, Katholieke Univ. Leuven (Belgium); Bruynseraede, Y [Lab. voor Vaste Stof-Fysika en Magnetisme, Katholieke Univ. Leuven (Belgium); Issi, J P [Unite de Physico-Chimie et de Physique des Materiaux, Univ. Catholique de Louvain, Louvain-la-Neuve (Belgium)

    1995-03-15

    The synthesis of very small samples has raised the need for a drastic miniaturization of the classical four-probe technique in order to realize electrical resistance measurements. Two methods to realize electrical contacts on very small fibers are described here. Using classical photolithography the electrical resistivity of a submicronic catalytic chemical vapour deposited filament is estimated. Scanning tunneling microscopy (STM) lithography allowed to attach small gold contacts to a small bundle (diameter 50 nm) of carbon nanotubes. This bundle is found to exhibit a semimetallic behavior at higher temperature and an unexpected drop of the electrical resistivity at lower temperature. (orig.)

  1. Measurement of the elastic cross section for positive pions on carbon at 142 MeV

    International Nuclear Information System (INIS)

    Oyer, A.T.

    1976-12-01

    A measurement of the elastic cross section dsigma/dΩ was made for the reaction π + + 12 C → π + + 12 C with 142 MeV pions at ten angles ranging from 35 to 85 0 in the laboratory. This experiment was done at the Los Alamos Meson Physics Facility. A double focusing magnetic spectrometer observed a cylindrical styrofoam target. The resulting momentum spectra were recorded by an array of nineteen totally depleted surface barrier detectors located at the spectrometer's focal plane. The spectra from the styrofoam were composed of peaks representing proton elastic, carbon elastic, carbon inelastic, and carbon quasi-elastic channels. A function made of Gaussians representing the two body channels and a distribution representing the quasi-elastic channel was fit to the data using a nonlinear least squares algorithm. The ratio of the carbon elastic to proton elastic cross sections was calculated from the areas of the corresponding Gaussians and then multiplied by the proton elastic cross section of Bugg et al eliminating several sources of systematic errors such as beam normalization. The differential cross sections were found to have the usual diffraction structure with a forward peak and a minimum near 55 0 . Finally, the carbon elastic cross sections were compared to similar π - + 12 C cross sections of Binon et al using the optical model

  2. Measurement of the elastic cross section for positive pions on carbon at 142 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Oyer, A.T.

    1976-12-01

    A measurement of the elastic cross section dsigma/d..cap omega.. was made for the reaction ..pi../sup +/ + /sup 12/C ..-->.. ..pi../sup +/ + /sup 12/C with 142 MeV pions at ten angles ranging from 35 to 85/sup 0/ in the laboratory. This experiment was done at the Los Alamos Meson Physics Facility. A double focusing magnetic spectrometer observed a cylindrical styrofoam target. The resulting momentum spectra were recorded by an array of nineteen totally depleted surface barrier detectors located at the spectrometer's focal plane. The spectra from the styrofoam were composed of peaks representing proton elastic, carbon elastic, carbon inelastic, and carbon quasi-elastic channels. A function made of Gaussians representing the two body channels and a distribution representing the quasi-elastic channel was fit to the data using a nonlinear least squares algorithm. The ratio of the carbon elastic to proton elastic cross sections was calculated from the areas of the corresponding Gaussians and then multiplied by the proton elastic cross section of Bugg et al eliminating several sources of systematic errors such as beam normalization. The differential cross sections were found to have the usual diffraction structure with a forward peak and a minimum near 55/sup 0/. Finally, the carbon elastic cross sections were compared to similar ..pi../sup -/ + /sup 12/C cross sections of Binon et al using the optical model.

  3. Measurement of the elastic cross section for positive pions on carbon at 142 MeV

    International Nuclear Information System (INIS)

    Oyer, A.T.

    1976-01-01

    A measurement of the elastic cross section dsigma/dOMEGA was made for the reaction π + + 12 C yields π + + 12 C with 142 MeV pions at ten angles ranging from 35 to 85 0 in the laboratory. This experiment was done at the Los Alamos Meson Physics Facility. A double focusing magnetic spectrometer observed a cylindrical styrofoam target. The resulting momentum spectra were recorded by an array of nineteen totally depleted surface barrier detectors located at the spectrometers focal plane. The spectra from the styrofoam were composed of peaks representing proton elastic, carbon elastic, carbon inelastic and carbon quasi-elastic channels. A function made of Gaussians representing the two body channels and a distribution representing the quasi-elastic channel was fit to the data using a nonlinear least squares algorithm. The ratio of the carbon elastic to proton elastic cross sections was calculated from the areas of the corresponding Gaussians and then multiplied by the proton elastic cross section of Bugg et al., eliminating several sources of systematic errors such as beam normalization. The differential cross sections were found to have the usual diffraction structure with a forward peak and a minimum near 55 0 . Finally, the carbon elastic cross sections were compared to similar π - + 12 C cross sections of Binon et al., using the optical model

  4. Measurements of total cross sections between 23 and 280 GeV/c

    International Nuclear Information System (INIS)

    Koehler, P.F.M.

    1975-01-01

    The high precision measurements of the total cross sections for π/sup +-/, K/sup +-/, p, and anti p scattering from H 2 and D 2 were continued with an extension of the energy range from 23 to 280 GeV/c

  5. Perceptions of Community College Presidents: Total Quality Management Performance Measures at Their Colleges

    Science.gov (United States)

    Riccardi, Mark T.

    2009-01-01

    Continuous Quality Improvement (CQI) measures such as Total Quality Management (TQM), Strategic Planning, Six Sigma, and the Balanced Scorecard are often met with skepticism among leaders of higher education. This study attempts to fill a gap in the literature regarding the study of relationships among specific variables, or building blocks,…

  6. Measurement of the π- proton total cross section from 5 to 15 GeV/c

    International Nuclear Information System (INIS)

    Lelouch, Daniel.

    1979-01-01

    An original method for total cross-section measurement based on a fast microcomputer processing events on line is described. An excellent accuracy is reached by a systematical control of numerous biases. It is shown that the experiment is a first approach to the study of narrow baryonic resonances a multiquark states ('color chemics') [fr

  7. Measurement methods and variability assessment of the Norway spruce total leaf area: Implications for remote sensing

    NARCIS (Netherlands)

    Homolova, L.; Lukes, P.; Malenovsky, Z.; Lhotakova, Z.; Kaplan, V.; Hanus, J.

    2013-01-01

    Estimation of total leaf area (LAT) is important to express biochemical properties in plant ecology and remote sensing studies. A measurement of LAT is easy in broadleaf species, but it remains challenging in coniferous canopies. We proposed a new geometrical model to estimate Norway spruce LAT and

  8. The construction of distant total distributed measuring and controlling system based on RS-232 communication

    International Nuclear Information System (INIS)

    Shi Chengying; Li Tiantuo; Zhu Wenkai; Zhang Quanhu

    1999-01-01

    The author discusses the construction of distant total distributed measuring and controlling system based on RS-232 communication. The merits of this system are simple construction, reliable performance, big communication distance, and wide covering range. The system fits in with application in radiation environment. The author also discusses the system's hardware equipment and communication protocol

  9. Objectively measured total and occupational sedentary time in three work settings

    NARCIS (Netherlands)

    Dommelen, P. van; Coffeng, J. K.; Ploeg, H.P. van der; Beek, A.J. van der; Boot, C.R.; Hendriksen, I.J.

    2016-01-01

    Background. Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged

  10. TOTAL AND HOT-WATER EXTRACTABLE CARBON RELATIONSHIP IN CHERNOZEM SOIL UNDER DIFFERENT CROPPING SYSTEMS AND LAND USE

    Directory of Open Access Journals (Sweden)

    Srdjan Šeremešić

    2013-12-01

    Full Text Available A study was conducted to determine the hot water extractable organic carbon (HWOC in 9 arable and 3 non arable soil samples on Haplic Chernozem. The hot water extractable carbon represents assimilative component of the total organic matter (OM that could contain readily available nutrients for plant growth. The obtained fraction of organic carbon (C makes up only a small percentage of the soil OM and directly reflects the changes in the rhizosphere. This labile fraction of the organic matter was separated by hot water extraction at 80°C. In our study the HWOC content in different samples ranged from 125 mg g-1 to 226 mg g-1. On the plots that are under native vegetation, higher values were determined (316 mg g-1 to 388 mg g-1. Whereas samples from arable soils were lower in HWOC. It was found that this extraction method can be successfully used to explain the dynamics of the soil OM. Soil samples with lower content of the total OM had lower HWOC content, indicating that the preservation of the OM depends on the renewal of its labile fractions.

  11. Uniform implantation of CNTs on total activated carbon surfaces: a smart engineering protocol for commercial supercapacitor applications.

    Science.gov (United States)

    Jiang, Jian; Li, Linpo; Liu, Yani; Liu, Siyuan; Xu, Maowen; Zhu, Jianhui

    2017-04-07

    The main obstacles to building better supercapacitors are still trade-offs between energy and power parameters. To promote commercial supercapacitor behaviors, proper optimization toward electrode configurations/architectures may be a feasible and effective way. We herein propose a smart and reliable electrode engineering protocol, by in situ implantation of carbon nanotubes (CNTs) on total activated carbon (AC) surfaces via a mild chemical vapor deposition process at ∼550 °C, using nickel nitrate hydroxide (NNH) thin films and waste ethanol solvents as the catalyst and carbon sources, respectively. The direct and conformal growth of NNH layers onto carbonaceous scaffold guarantees the later uniform implantation of long and high-quality CNTs on total AC outer surfaces. Such fluffy and entangled CNTs preserve ionic diffusion channels, well connect neighboring ACs and function as superhighways for electrons transfer, endowing electrodes with outstanding capacitive behaviors including large output capacitances of ∼230 F g -1 in 1 M Na 2 SO 4 neutral solution and ∼502.5 F g -1 in 6 M KOH using Ni valence state variation, and very negligible capacity decay in long-term cycles. Furthermore, a full symmetric supercapacitor device of CNTs@ACs//CNTs@ACs has been constructed, capable of delivering both high specific energy and power densities (maximum values reaching up to ∼97.2 Wh kg -1 and ∼10.84 kW kg -1 ), which holds great potential in competing with current mainstream supercapacitors.

  12. An initial SPARROW model of land use and in-stream controls on total organic carbon in streams of the conterminous United States

    Science.gov (United States)

    Shih, Jhih-Shyang; Alexander, Richard B.; Smith, Richard A.; Boyer, Elizabeth W.; Shwarz, Grogory E.; Chung, Susie

    2010-01-01

    Watersheds play many important roles in the carbon cycle: (1) they are a site for both terrestrial and aquatic carbon dioxide (CO2) removal through photosynthesis; (2) they transport living and decomposing organic carbon in streams and groundwater; and (3) they store organic carbon for widely varying lengths of time as a function of many biogeochemical factors. Using the U.S. Geological Survey (USGS) Spatially Referenced Regression on Watershed Attributes (SPARROW) model, along with long-term monitoring data on total organic carbon (TOC), this research quantitatively estimates the sources, transport, and fate of the long-term mean annual load of TOC in streams of the conterminous United States. The model simulations use surrogate measures of the major terrestrial and aquatic sources of organic carbon to estimate the long-term mean annual load of TOC in streams. The estimated carbon sources in the model are associated with four land uses (urban, cultivated, forest, and wetlands) and autochthonous fixation of carbon (stream photosynthesis). Stream photosynthesis is determined by reach-level application of an empirical model of stream chlorophyll based on total phosphorus concentration, and a mechanistic model of photosynthetic rate based on chlorophyll, average daily solar irradiance, water column light attenuation, and reach dimensions. It was found that the estimate of in-stream photosynthesis is a major contributor to the mean annual TOC load per unit of drainage area (that is, yield) in large streams, with a median share of about 60 percent of the total mean annual carbon load in streams with mean flows above 500 cubic feet per second. The interquartile range of the model predictions of TOC from in-stream photosynthesis is from 0.1 to 0.4 grams (g) carbon (C) per square meter (m-2) per day (day-1) for the approximately 62,000 stream reaches in the continental United States, which compares favorably with the reported literature range for net carbon fixation by

  13. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Rossa, Riccardo [Belgian nuclear research centre SCK.CEN (Belgium); Universite Libre de Bruxelles (Belgium); Borella, Alessandro; Van der Meer, Klaas [Belgian nuclear research centre SCK.CEN. Boeretang 200, 2400 Mol (Belgium); Labeau, Pierre-Etienne; Pauly, Nicolas [Universite Libre de Bruxelles. Av. F. D. Roosevelt 50, B1050 Brussels (Belgium)

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts

  14. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Directory of Open Access Journals (Sweden)

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  15. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Science.gov (United States)

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  16. Research and Evaluation of Relief Effect on Total Carbon Changes in Soil

    Directory of Open Access Journals (Sweden)

    Mantas Pranskevičius

    2011-04-01

    Full Text Available Soil is one of the major subsystems of the natural landscape of land and serves to the man as the main source of food resources for exclusive importance. One of the burning problems of mankind in the future will be the preservation of land soils, their fertility and health status under conditions of the increased pressure of human and the degradation of natural landscape conditions. As an additional negative factor taking place in nature is that the Earth will have to overcome the effects of global warming that will inevitably occur in Lithuanian agriculture. This paper examines the general evolution of carbon considering relief. Currently, the erosion of soil surface in Lithuania makes 30–50 %. Soil affected by erosion losses its fertility thus promoting further degradation of land.Article in Lithuanian

  17. Measurements of the Total, Elastic, Inelastic and Diffractive Cross Sections with the ATLAS Detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00237700; The ATLAS collaboration

    2016-01-01

    The main results of the total, elastic and inelastic cross sections measurements performed by the ATLAS ALFA detectors are presented. The independent inelastic cross section measurement done using Minimum Bias Trigger Scintillators is also shown. Next, the single diffractive di-jet production and gap survival probability are briefly described. After the event selection, it was found that the diffractive component is needed for a more complete description of data. Finally, the exclusive lepton pair production analysis in electron and muon channels is also described. The measured cross sections were found to be consistent with the theory prediction.

  18. ANALISIS TOTAL PRODUCTIVE MAINTENANCE PADA LINE 8/CARBONATED SOFT DRINK PT COCA-COLA BOTTLING INDONESIA CENTRAL JAVA

    Directory of Open Access Journals (Sweden)

    Darminto Pujotomo

    2012-02-01

    Full Text Available PT. Coca-Cola Bottling Indonesia (CCBI Central Java merupakan salah satu perusahaan produsen minuman ringan yang terkemuka di Indonesia, dengan dua jenis kelompok produk yang dihasilkan yaitu minuman karbonasi/Carbonated Soft Drink (Coca-Cola, Sprite, dan Fanta dan non-karbonasi (Frestea dan Ades. Dalam usaha untuk mempertahankan mutu dan meningkatkan produktifitas, salah satu faktor yang harus diperhatikan adalah masalah perawatan fasilitas/mesin produksi.  Makalah ini membahas mengenai penyebab dan akibat yang ditimbulkan oleh breakdown mesin terjadi pada Line 8/Carbonated Soft Drink, khususnya pada conveyor, filler machine, dan bottle washer machine. Untuk mendapatkan mesin yang dapat terjaga keterandalannya dibutuhkan suatu konsep yang baik. Total Productive Maintenance (TPM merupakan sebuah konsep yang baik untuk merealisasikan hal tersebut. Konsep ini, selain melibatkan semua personil dalam perusahaan, juga bertujuan untuk merawat semua fasilitas produksi yang dimiliki perusahaan.Data yang digunakan merupakan data breakdown conveyor, filler machine, dan bottle washer machine dari ME Monthly Report PT.CCBI selama bulan Januari-Desember 2005 khususnya line 8. Selain itu makalah ini juga membahas performance maintenance PT. Coca-Cola Bottling Indonesia-Central Java, dengan memperhitungkan nilai Mean Time Beetwen Failure (MTBF, Mean Time To Repair (MTTR, serta Availability mesin, dengan menggunakan data record Line 8 selama bulan Mei 2006 sampai bulan Juli 2006. Sehingga nantinya akan diketahui informasi keadaan aktual dari perusahaan tentang sistem perawatannya, khususnya pada Line 8/Carbonated Soft Drink apakah baik atau buruk. Kata kunci : Total Production Maintenance, Conveyor, Filler Machine, Bottle Washer Machine, Performance Maintenance   PT. Coca-Cola Bottling Indonesia (CCBI-Central Java represent one of notable light beverage producer company in Indonesia, with two product group type yielded is carbonated beverage/Carbonated Soft

  19. Geometric measure of quantum discord and total quantum correlations in an N-partite quantum state

    International Nuclear Information System (INIS)

    Hassan, Ali Saif M; Joag, Pramod S

    2012-01-01

    Quantum discord, as introduced by Ollivier and Zurek (2001 Phys. Rev. Lett. 88 017901), is a measure of the discrepancy between quantum versions of two classically equivalent expressions for mutual information and is found to be useful in quantification and application of quantum correlations in mixed states. It is viewed as a key resource present in certain quantum communication tasks and quantum computational models without containing much entanglement. An early step toward the quantification of quantum discord in a quantum state was by Dakic et al (2010 Phys. Rev. Lett. 105 190502) who introduced a geometric measure of quantum discord and derived an explicit formula for any two-qubit state. Recently, Luo and Fu (2010 Phys. Rev. A 82 034302) introduced a generic form of the geometric measure of quantum discord for a bipartite quantum state. We extend these results and find generic forms of the geometric measure of quantum discord and total quantum correlations in a general N-partite quantum state. Further, we obtain computable exact formulas for the geometric measure of quantum discord and total quantum correlations in an N-qubit quantum state. The exact formulas for the N-qubit quantum state can be used to get experimental estimates of the quantum discord and the total quantum correlation. (paper)

  20. ATLAS-ALFA measurements on the total cross section and diffraction

    CERN Document Server

    Mortensen, Simon Stark; The ATLAS collaboration

    2015-01-01

    The measurement of the total pp cross section at the LHC at $\\sqrt{s}=7$ TeV with the ALFA subdetector of ATLAS is presented in this talk. In a special run with $\\beta^*=90$ m beam optics corresponding to an integrated luminosity of 80 $\\text{mb}^{-1}$ the differential elastic cross section is measured in the range from $-t=0.0025\\text{ GeV}^2$ to $-t=0.38\\text{ GeV}^2$. The total cross section $\\sigma(pp\\rightarrow X)$ is extracted using the Optical Theorem by extrapolation of the differential elastic cross section to $t=0\\text{ GeV}^2$. Prospects for diffractive measurements using ALFA to detect the intact proton(s) is also discussed.

  1. Total Measurement Uncertainty for the Plutonium Finishing Plant (PFP) Segmented Gamma Scan Assay System

    CERN Document Server

    Fazzari, D M

    2001-01-01

    This report presents the results of an evaluation of the Total Measurement Uncertainty (TMU) for the Canberra manufactured Segmented Gamma Scanner Assay System (SGSAS) as employed at the Hanford Plutonium Finishing Plant (PFP). In this document, TMU embodies the combined uncertainties due to all of the individual random and systematic sources of measurement uncertainty. It includes uncertainties arising from corrections and factors applied to the analysis of transuranic waste to compensate for inhomogeneities and interferences from the waste matrix and radioactive components. These include uncertainty components for any assumptions contained in the calibration of the system or computation of the data. Uncertainties are propagated at 1 sigma. The final total measurement uncertainty value is reported at the 95% confidence level. The SGSAS is a gamma assay system that is used to assay plutonium and uranium waste. The SGSAS system can be used in a stand-alone mode to perform the NDA characterization of a containe...

  2. Measurement of total risk of spontaneous abortion: the virtue of conditional risk estimation

    DEFF Research Database (Denmark)

    Modvig, J; Schmidt, L; Damsgaard, M T

    1990-01-01

    The concepts, methods, and problems of measuring spontaneous abortion risk are reviewed. The problems touched on include the process of pregnancy verification, the changes in risk by gestational age and maternal age, and the presence of induced abortions. Methods used in studies of spontaneous...... abortion risk include biochemical assays as well as life table technique, although the latter appears in two different forms. The consequences of using either of these are discussed. It is concluded that no study design so far is appropriate for measuring the total risk of spontaneous abortion from early...... conception to the end of the 27th week. It is proposed that pregnancy may be considered to consist of two or three specific periods and that different study designs should concentrate on measuring the conditional risk within each period. A careful estimate using this principle leads to an estimate of total...

  3. Measuring total health inequality: adding individual variation to group-level differences

    Directory of Open Access Journals (Sweden)

    Gakidou Emmanuela

    2002-08-01

    Full Text Available Abstract Background Studies have revealed large variations in average health status across social, economic, and other groups. No study exists on the distribution of the risk of ill-health across individuals, either within groups or across all people in a society, and as such a crucial piece of total health inequality has been overlooked. Some of the reason for this neglect has been that the risk of death, which forms the basis for most measures, is impossible to observe directly and difficult to estimate. Methods We develop a measure of total health inequality – encompassing all inequalities among people in a society, including variation between and within groups – by adapting a beta-binomial regression model. We apply it to children under age two in 50 low- and middle-income countries. Our method has been adopted by the World Health Organization and is being implemented in surveys around the world; preliminary estimates have appeared in the World Health Report (2000. Results Countries with similar average child mortality differ considerably in total health inequality. Liberia and Mozambique have the largest inequalities in child survival, while Colombia, the Philippines and Kazakhstan have the lowest levels among the countries measured. Conclusions Total health inequality estimates should be routinely reported alongside average levels of health in populations and groups, as they reveal important policy-related information not otherwise knowable. This approach enables meaningful comparisons of inequality across countries and future analyses of the determinants of inequality.

  4. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  5. Field Measurements of Black Carbon Yields from Gas Flaring.

    Science.gov (United States)

    Conrad, Bradley M; Johnson, Matthew R

    2017-02-07

    Black carbon (BC) emissions from gas flaring in the oil and gas industry are postulated to have critical impacts on climate and public health, but actual emission rates remain poorly characterized. This paper presents in situ field measurements of BC emission rates and flare gas volume-specific BC yields for a diverse range of flares. Measurements were performed during a series of field campaigns in Mexico and Ecuador using the sky-LOSA optical measurement technique, in concert with comprehensive Monte Carlo-based uncertainty analyses. Parallel on-site measurements of flare gas flow rate and composition were successfully performed at a subset of locations enabling direct measurements of fuel-specific BC yields from flares under field conditions. Quantified BC emission rates from individual flares spanned more than 4 orders of magnitude (up to 53.7 g/s). In addition, emissions during one notable ∼24-h flaring event (during which the plume transmissivity dropped to zero) would have been even larger than this maximum rate, which was measured as this event was ending. This highlights the likely importance of superemitters to global emission inventories. Flare gas volume-specific BC yields were shown to be strongly correlated with flare gas heating value. A newly derived correlation fitting current field data and previous lab data suggests that, in the context of recent studies investigating transport of flare-generated BC in the Arctic and globally, impacts of flaring in the energy industry may in fact be underestimated.

  6. Carbon-14 dating of tree rings for tritium measurement

    International Nuclear Information System (INIS)

    Yamada, Y.; Yasuike, K.; Kiriyama, N.; Komura, K.; Ueno, K.

    1998-01-01

    The carbon-14 concentration in tree-ring cellulose of an 80-year-old pine tree which has been used for tritium measurement was measured during the 1941-1987 period. This was done to determine the formation year of each tree ring in order to study the pathway of tritium uptake into the tree rings. In the 1941 to 1953 period, the δ 14 C value remained slightly lower than 0 per mille. It began to increase from 1954 to a small broad peak of 250 per mille between 1959 and 1961, followed by rapid increase to the highest value of approximately 800 per mille in 1964. Since 1964, it had been diminishing year by year to reach a level of 190 per mille in 1987. The two peak years coincided with those in the known carbon-14 patterns in tree rings. However, there existed a difference in the amplitude of the δ 14 C values during the period of 1963-1967. (author)

  7. Measurement of the total antioxidant response in preeclampsia with a novel automated method.

    Science.gov (United States)

    Harma, Mehmet; Harma, Muge; Erel, Ozcan

    2005-01-10

    Preeclampsia is one of the most serious complications of pregnancy. Free radical damage has been implicated in the pathophysiology of this condition. In this study, we aimed to measure the antioxidant capacity in plasma samples from normotensive and preeclamptic pregnant women to evaluate their antioxidant status using a more recently developed automated measurement method. Our study group contained 42 women, 24 of whom had preeclampsia, while 18 had normotensive pregnancies. We measured the total plasma antioxidant capacity for all patients, as well as the levels of four major individual plasma antioxidant components; albumin, uric acid, ascorbic acid and bilirubin, and as a reciprocal measure, their total plasma peroxide levels. Statistically significant differences (determined using Student's t-test) were noted between the normotensive and the preeclamptic groups for their total antioxidant responses and their vitamin C levels (1.31 +/- 0.12 mmol versus 1.06 +/- 0.41 mmol Trolox eq./L; 30.2 +/- 17.83 micromol/L versus 18.1 +/- 11.37 micromol/L, respectively), which were both considerably reduced in the preeclamptic patients. In contrast, the total plasma peroxide levels were significantly elevated in this group (49.8 +/- 14.3 micromol/L versus 38.8 +/- 9.6 micromol/L). We found a decreased total antioxidant response in preeclamptic patients using a simple, rapid and reliable automated colorimetric assay, which may suitable for use in any routine clinical biochemistry laboratory, and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow up of the levels of oxidative stress in preeclampsia.

  8. Total hemispherical emittance measured at high temperatures by the calorimetric method

    International Nuclear Information System (INIS)

    DiFilippo, F.; Mirtich, M.J.; Banks, B.A.; Stidham, C.; Kussmaul, M.

    1994-01-01

    A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements (± 5 percent). The probable error of the CVE measurements was typically less than 1 percent

  9. Measurement of Total Condensation on a Shrouded Cryogenic Surface using a Single Quart Crystal Microbalance

    International Nuclear Information System (INIS)

    Haid, B.J.; Malsbury, T.N.; Gibson, C.R.; Warren, C.T.

    2008-01-01

    A single quartz crystal microbalance (QCM) is cooled to 18 K to measure condensation rates inside of a retractable ''shroud'' enclosure. The shroud is of a design intended to minimize condensate on fusion targets to be fielded at the National Ignition Facility (NIF). The shroud has a double-wall construction with an inner wall that may be cooled to 75-100 K. The QCM and the shroud system were mounted in a vacuum chamber and cooled using a cryocooler. Condensation rates were measured at various vacuum levels and compositions, and with the shroud open or closed. A technique for measuring total condensate during the cooldown of the system with an accuracy of better than 1.0 x 10 -6 g/cm 2 was also demonstrated. The technique involved a separate measurement of the condensate-free crystal frequency as a function of temperature that was later applied to the measurement of interest

  10. Validity of estimating the organic carbon content of basin sediment using color measurements

    International Nuclear Information System (INIS)

    Sasaki, Toshinori; Sugai, Toshihiko; Ogami, Takashi; Yanagida, Makoto; Yasue, Ken-ichi

    2010-01-01

    Psychometric lightness (L* value) measured by a colorimeter offers a rapid means of obtaining the organic carbon content of sediment. We measured peat and lacustrine sediments covering the past 300 ka - 106 samples for L* value and 197 samples for organic carbon content. L* values are highly correlated with organic carbon contents. Therefore, L* values are a convenient alternative to measuring organic carbon contents. (author)

  11. Proportion of biogenic carbon in flue gas by carbon-14 measurement

    International Nuclear Information System (INIS)

    Lehtomaeki, J.; Antson, O.; Hongisto, M.; Knuuttila, M.; Roine, J.; Raesaenen, J.; Tormonen, K.; Jungner, H.

    2007-01-01

    The subject of this project is closely related to EU's emissions trading system and to the current and future monitoring needs therein. The determination of fossil part of emissions originated from various fuels by stack measurements or by laboratory analyses could possibly find users also in other fields outside the ETS (e.g. waste incineration). After the market analysis and preliminary measurements carried out in the previous Biocarbon project this project focused on the development of the sampling method for stack measurements and to the validation of isotope measurements. The results obtained for fossil proportion of the fuel by current methods will be compared to those obtained by isotope measurements. The operation of the sampling system was tested in long period tests in plant conditions. Moreover, the sample preparation methods and isotope measurements were validated by measuring the proportions of biogenic and fossil carbon of known traffic fuel mixtures. The developed service concept can also be utilised as a fraud prevention measure related to the expanding international biofuels-trade. (orig.)

  12. Proportion of biogenic carbon in flue gas by carbon-14 measurement - part 2; Biohiili 2

    Energy Technology Data Exchange (ETDEWEB)

    Lehtomaeki, J.; Antson, O.; Hongisto, M. (VTT Technical Research Centre of Finland, Espoo (Finland)) (and others)

    2009-07-01

    The subject of this project is closely related to EU's emissions trading system and to the current and future monitoring needs therein. The determination of fossil part of emissions originated from various fuels by stack measurements or by laboratory analyses could possibly find users also in other fields outside the ETS - Emission Trading Scheme (e.g. waste incineration). After the market analysis and preliminary measurements carried out in the previous Biocarbon project this project focused on the development of the sampling method for stack measurements and to the validation of isotope measurements. The results obtained for fossil proportion of the fuel by current methods will be compared to those obtained by isotope measurements. The operation of the sampling system was tested in long period tests in plant conditions. Moreover, the sample preparation methods and isotope measurements were validated by measuring the proportions of biogenic and fossil carbon of known traffic fuel mixtures. The developed method can also be utilised as a fraud prevention measure related to the expanding international biofuels-trade. (orig.)

  13. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  14. Measuring coral calcification under ocean acidification: methodological considerations for the 45Ca-uptake and total alkalinity anomaly technique

    Directory of Open Access Journals (Sweden)

    Stephanie Cohen

    2017-09-01

    Full Text Available As the oceans become less alkaline due to rising CO2 levels, deleterious consequences are expected for calcifying corals. Predicting how coral calcification will be affected by on-going ocean acidification (OA requires an accurate assessment of CaCO3 deposition and an understanding of the relative importance that decreasing calcification and/or increasing dissolution play for the overall calcification budget of individual corals. Here, we assessed the compatibility of the 45Ca-uptake and total alkalinity (TA anomaly techniques as measures of gross and net calcification (GC, NC, respectively, to determine coral calcification at pHT 8.1 and 7.5. Considering the differing buffering capacity of seawater at both pH values, we were also interested in how strongly coral calcification alters the seawater carbonate chemistry under prolonged incubation in sealed chambers, potentially interfering with physiological functioning. Our data indicate that NC estimates by TA are erroneously ∼5% and ∼21% higher than GC estimates from 45Ca for ambient and reduced pH, respectively. Considering also previous data, we show that the consistent discrepancy between both techniques across studies is not constant, but largely depends on the absolute value of CaCO3 deposition. Deriving rates of coral dissolution from the difference between NC and GC was not possible and we advocate a more direct approach for the future by simultaneously measuring skeletal calcium influx and efflux. Substantial changes in carbonate system parameters for incubation times beyond two hours in our experiment demonstrate the necessity to test and optimize experimental incubation setups when measuring coral calcification in closed systems, especially under OA conditions.

  15. Electrochemical impedance measurement of a carbon nanotube probe electrode

    International Nuclear Information System (INIS)

    Inaba, Akira; Takei, Yusuke; Kan, Tetsuo; Shimoyama, Isao; Matsumoto, Kiyoshi

    2012-01-01

    We measured and analyzed the electrochemical impedance of carbon nanotube (CNT) probe electrodes fabricated through the physical separation of insulated CNT bridges. The fabricated CNT electrodes were free-standing CNTs that were completely covered with an insulator, except for their tips. Typical dimensions of the nanoelectrodes were 1–10 nm in CNT diameter, 80–300 nm in insulator diameter, 0.5–4 μm in exposed CNT length and 1–10 μm in probe length. The electrochemical impedance at frequencies ranging from 40 Hz to 1 MHz was measured in physiological saline. The measured impedance of the CNT electrode was constant at 32 MΩ at frequencies below 1 kHz and was inversely proportional to frequency at frequencies above 10 kHz. By means of comparison with the parasitic capacitive impedance of the insulator membrane, we confirmed that the electrode was sufficiently insulated such that the measured constant impedance was given by the exposed CNT tip. Consequently, we can use the CNT electrode for highly localized electrochemical impedance measurements below 1 kHz. Considering an equivalent circuit and the nanoscopic dimensions of the CNT electrode, we demonstrated that the constant impedance was governed by diffusion impedance, whereas the solution resistance, charge-transfer resistance and double-layer capacitance were negligible. (paper)

  16. Measuring and modeling carbon balance in mountainous Northern Rocky mixed conifer forests

    Science.gov (United States)

    Hudiburg, T. W.; Berardi, D.; Stenzel, J.

    2016-12-01

    Drought and wildfire caused by changing precipitation patterns, increased temperatures, increased fuel loads, and decades of fire suppression are reducing forest carbon uptake from local to continental scales. This trend is especially widespread in Idaho and the intermountain west and has important implications for climate change and forest management options. Given the key role of forests in climate regulation, understanding forest response to drought and the feedbacks to the atmosphere is a key research and policy-relevant priority globally. As temperature, fire, and precipitation regimes continue to change and there is increased risk of forest mortality, measurements and modeling at temporal and spatial scales that are conducive to understanding the impacts and underlying mechanisms of carbon and nutrient cycling become critically important. Until recently, sub-daily measurements of ecosystem carbon balance have been limited in remote, mountainous terrain (e.g Northern Rocky mountain forests). Here, we combine new measurement technology and state-of-the-art ecosystem modeling to determine the impact of drought on the total carbon balance of a mature, mixed-conifer forest in Northern Idaho. Our findings indicate that drought had no impact on aboveground NPP, despite early growing season reductions in soil moisture and fine root biomass compared to non-drought years in the past. Modeled estimates of net ecosystem production (NEP) suggest that a simultaneous reduction in heterotrophic respiration increased the carbon sink for this forest. This has important implications for forest management, such as thinning where the objectives are to increase forest resilience to fire and drought, but may decrease NEP.

  17. Total cross section measurement of radioactive isotopes with a thin beam neutron spectrometer

    International Nuclear Information System (INIS)

    Razbudej, V.F.; Vertebnyj, V.P.; Padun, G.S.; Muravitskij, A.V.

    1975-01-01

    The method for measuring the neutron total cross sections of radioactive isotopes by a time-of-flight spectrometer with a narrow (0.17 mm in diameter) beam of thermal neutrons is described. The distinguishing feature of this method is the use of capillary samples with a small amount of substance (0.05-1.0 mg). The energy range is 0.01-0.3 eV. The total cross sections of irradiated samples of sub(153)Eu and sub(151)Eu are measured. From them are obtained the cross sections of sub(152)Eu (Tsub(1/2)=12.4 g) and of sub(154)E (Tsub(1/2)=8.6 yr); they equal 11400+-1400 and 1530+-190 barn at E=0.0253 eV. The cross section of the sub(152)Eu absorption for the thermal spectrum (T=333 K) is determined by the activation method; it is 8900+-1200 barn

  18. Total pion cross section measurements. Annual progress report, 1 January 1977--31 December 1978

    International Nuclear Information System (INIS)

    Jakobson, M.J.; Jeppesen, R.H.

    1978-01-01

    The pion-nucleus total cross section runs were completed. The principal effort for the past year has been devoted to data analysis. The experiment was primarily designed to provide an accurate measurement of total cross section differences for pairs of isotopes. Data were published on neutron radii of calcium isotopes and on pion cross section measurements for aligned holmium. The π+- data to be published include targets and energies for 4 He, 23 → 90 MeV; 12 C, 13 C, 23 → 240 MeV; 6 Li, 7 Li, 9 Be, 10 B, 11 B, 43 → 215 MeV; 16 O, 18 O, 40 Ca, 44 Ca, 48 Ca, 43 → 240 MeV; 45 Sc, 51 V, Al, Cu, Sn, Ho, Pb, 60 → 215 MeV

  19. Measurement of total body calcium in osteoporotic patients treated with salmon calcitonin

    International Nuclear Information System (INIS)

    Zanzi, I.; Thompson, K.; Cohn, S.H.

    1981-01-01

    In the past, the evaluation of therapies for osteoporosis has been limited by the lack of a suitable quantitative end point. The introduction of the technique of in vivo total body neutron activation analysis (TBNAA) has made possible the precise and accurate measurement of total body calcium (TBCa). Since almost 99 percent of TBCa is in the skeleton, TBNAA gives a direct measurement of skeletal mass. Thus, changes in skeletal mass serve as an objective criterion in the evaluation of the efficacy of the therapy in osteoporosis. Studies performed at Brookhaven National Laboratory and elsewhere have reported the use of calcitonin (CT) in the treatment of primary osteoporosis and related conditions in a limited number of patients. The physiological effects of CT as an inhibitor of bone resorption has been the rationale of its use. The results of a randomized, controlled, 2 year therapeutical trial of CT in a group of postmenopausal osteoporotic women are presented in this report

  20. Measurements of effective total macroscopic cross sections and effective energy of continuum beam

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisao [Rikkyo Univ., Yokosuka, Kanagawa (Japan). Inst. for Atomic Energy

    1998-03-01

    Two practically useful quantities are introduced in this study to characterize a continuum neutron beam and to describe transmission phenomena of the beam in field of quantitative neutron radiography: an effective energy instead of a peak energy or a mean energy of the spectrum and an effective total macroscopic (ETM) cross section instead of a total macroscopic (TM) cross section defined at the monochromatic energy. The effective energy was evaluated by means of energy dependence of ETM cross section. To realize the method a beam quality indicator (BQI) has been proposed recently. Several effective energies were measured for non-filtered, filtered neutron beams, and outputs of neutron guide tubes in world by the BQI. A thermal neutron beam and three beams modulated by Pb filters with different thicknesses are studied to measure ETM cross sections for various materials and summarized in a table. Validity of the effective energy determined by the BQI is discussed relating with ETM cross sections of materials. (author)

  1. Changes in body chemical composition with age measured by total-body neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Vaswani, A.; Zanzi, I.; Aloia, J.F.; Roginsky, M.S.; Ellis, K.J.

    1976-01-01

    Total-body levels of calcium and phosphorus (reflecting skeletal mass) and total-body levels of potassium (reflecting muscle mass) were measured by neutron activation analysis in 39 men and 40 women ages 30 to 90 yr. In order to intercompare the total body calcium (TBCa) values in a heterogeneous population, such as this, it was necessary to normalize the data for skeletal size. The normalization consisted of dividing the absolute calcium level by the predicted calcium level for each individual matched to a set of critical parameters. The parameter used in the computation of normal values were age, sex, muscle mass, i.e., total body potassium (TBK) and height. For the calcium data of the women, it was necessary to add an age correction factor after the age of 55 yr. The calcium ratio (mean ratio of the predicted to measured TBCa) in men was 1.000 +- 7.8 percent and in women 0.996 +- 7.1 percent. The TBCa of normal males and females can thus be predicted to +-13 percent (at the 90 percent confidence level). An exception to this was found in males (70 to 90 yr) who exhibited a mean calcium ratio greater than 1.13

  2. Comprehensive measurement of total nondigestible carbohydrates in foods by enzymatic-gravimetric method and liquid chromatography.

    Science.gov (United States)

    Nishibata, Toyohide; Tashiro, Kouichi; Kanahori, Sumiko; Hashizume, Chieko; Kitagawa, Machiko; Okuma, Kazuhiro; Gordon, Dennis T

    2009-09-09

    Total nondigestible carbohydrate (NDC) in foods was determined by combining, not modifications, AOAC Official Methods 991.43, 2001.03, and 2002.02. Total NDC included insoluble dietary fiber (IDF) + high-molecular-weight soluble dietary fiber (HMWSDF), nondigestible oligosaccharides (NDO) not precipitated in ethanol solution, and resistant starch (RS). Eight sources of NDC (cellulose, wheat bran, gum arabic, resistant maltodextrin, polydextrose, fructooligosaccharide, galactooligosaccharides, and RS) were incorporated in different combinations into standard formula bread samples. All of the NDC sources and bread samples were analyzed for their (1) IDF + HMWSDF content with corrections for residual RS amount using AOAC Official Method 991.43, (2) NDO by liquid chromatography (LC) in AOAC Official Method 2001.03, and (3) RS by AOAC Official Method 2002.02. The correlation coefficient (R(2)) comparing calculated amounts versus measured amounts of total NDC in 11 bread samples was 0.92. Analysis of commercial food samples was also well matched with the DF + NDO value on their nutritional label. Consequently, we confirmed a single measurement of LC can determine all NDO in foods, and total NDC in foods can be determined by unifying existing AOAC Official Methods.

  3. Argon intermolecular potential from a measurement of the total scattering cross-section

    International Nuclear Information System (INIS)

    Wong, Y.W.

    1975-01-01

    An inversion method to obtain accurate intermolecular potentials from experimental total cross section measurements is presented. This method is based on the high energy Massey--Smith approximation. The attractive portion of the potential is represented by a multi-parameter spline function and the repulsive part by a Morse function. The best fit potential is obtained by a least squares minimization based on comparison of experimental cross sections with those obtained by a Fourier transform of the reduced Massey--Smith phase shift curve. An experimental method was developed to obtain the total cross sections needed for the above inversion procedure. In this technique, integral cross sections are measured at various resolutions and the total cross section is obtained by extrapolating to infinite resolution. Experimental results obtained for the Ar--Ar system are in excellent agreement with total cross sections calculated using the Barker-Fisher-Watts potential. Inversion of the data to obtain a potential distinguishable from the BFW-potential requires an extension of the method based on the Massey--Smith approximation to permit use of JWKB phase shifts and was not attempted

  4. Plutonium Finishing Plant (PFP) Generalized Geometry Holdup Calculations and Total Measurement Uncertainty

    International Nuclear Information System (INIS)

    Keele, B.D.

    2005-01-01

    A collimated portable gamma-ray detector will be used to quantify the plutonium content of items that can be approximated as a point, line, or area geometry with respect to the detector. These items can include ducts, piping, glove boxes, isolated equipment inside of gloveboxes, and HEPA filters. The Generalized Geometry Holdup (GGH) model is used for the reduction of counting data. This document specifies the calculations to reduce counting data into contained plutonium and the associated total measurement uncertainty.

  5. Objectively Measured Total and Occupational Sedentary Time in Three Work Settings

    OpenAIRE

    van Dommelen, Paula; Coffeng, Jennifer K.; van der Ploeg, Hidde P.; van der Beek, Allard J.; Boot, C?cile R. L.; Hendriksen, Ingrid J. M.

    2016-01-01

    Background. Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged sedentary bouts. Methods. Data were obtained using ActiGraph accelerometers from employees of: 1) a financial service provider (n = 49 men, 31 women), 2) two research institutes (n = 30 men, 57 wom...

  6. Measurement of total reaction cross sections of exotic neutron rich nuclei

    International Nuclear Information System (INIS)

    Mittig, W.; Chouvel, J.M.; Wen Long, Z.

    1987-01-01

    Total reaction cross-sections of neutron rich nuclei from C to Mg in a thick Si-target have been measured using the detection of the associated γ-rays in a 4Π-geometry. This cross-section strongly increases with neutron excess, indicating an increase of as much as 15% of the reduced strong absorption radius with respect to stable nuclei

  7. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  8. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  9. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  10. Discriminative ability of total body bone-mineral measured by dual photon absorptiometry

    International Nuclear Information System (INIS)

    Gotfredsen, A.; Poedenphant, J.; Nilas, L.; Christiansen, C.

    1989-01-01

    We investigated the descriminative ability of total body bone-mineral expressed as the total body bone-density (TBBD) measured by dual photon absorptiometry (DPA) in 79 healthy premenopausal women, 27 healthy postmenopausal women, and 120 female osteoporotic fracture patients presenting with either Colles' fracture, vertebral fracture or femoral neck-fracture. TBBD was compared to the bone-mineral density of the lumbar spine (BMD spine ) also measured by DPA, and to the bone-mineral content of the forearms (BMC forearm ) measured by single photon absorptiometry (SPA). TBBD, BMD spine and BMC forearm showed that all the fracture patient groups had significantly reduced bone-mass. Using receiver operating characteristic (ROC) analysis, we found that TBBD had a tendency towards better discriminative ability than BMD spine or BMC forearm with regard to the discrimination between healthy premenopausal women and the three types of osteoporotic fractures. BMC forearm had an intermediate position, whereas BMD spine had the smallest discriminative ability. TBBD also discriminated better between healthy postmenopausal women and hip-fracture patients than BMD spine or BMC forearm , whereas there was no significant difference between the three methods regarding the discrimination between the healthy postmenopausal women and the Colles' and spinal fracture patients. We conclude that the TBBD measurement by DPA has a discriminative potential which is better than the local spine or forearm measurements. (author)

  11. Determination of total and electrolabile copper in agricultural soil by using disposable modified-carbon screen-printed electrodes.

    Science.gov (United States)

    Faucher, Stéphane; Cugnet, Cyril; Authier, Laurent; Lespes, Gaëtane

    2014-02-01

    The objective of the study is to evaluate modified-carbon screen-printed working electrodes (SPE) combined with square wave anodic stripping voltammetry (SWASV) to determine electrolabile and total copper in soils with the perspective to assess the environmental hazard resulting from copper anthropogenic contamination. The voltammetric method was investigated using a mineralized certified reference soil such that it can be assumed that the copper was totally under electrolabile form in the solution of mineralized soil. In optimal conditions, a copper recovery of 97% and a relative standard deviation (RSD) of 9% were found. The limits of detection and quantification for copper were 0.4 and 1.3 μg L(-1), respectively. Finally, the method was applied on soil leachates, which allowed evaluating the cupric transfer from the soil to the leachates and quantifying the electrolabile copper part in leachates.

  12. Surface Sediment Analysis on Petroleum Hydrocarbon and Total Organic Carbon from Coastal Area of Papar to Tuaran, Sabah

    International Nuclear Information System (INIS)

    Siti Aishah Mohd Ali; Payus, C.; Masni Mohd Ali

    2015-01-01

    Total petroleum hydrocarbons (TPH) and total organic carbon (TOC) were investigated in surface sediments along coastal area of Papar to Tuaran, Sabah. Surface sediment samples were collected in 24 different stations in each area by using Ponar grab sampler. Samples were extracted for TPH using standard method sediment/ sludge APHA 5520E and analyzed using UV/VIS spectrophotometer while for TOC method analysis using United Nations Environment Programme (UNEP)/ MAP Athens (2006). The range of TPH concentrations in surface sediments were recorded at 0.24 - 20.65 mg/ kg dw Miri crude oil equivalents, meanwhile the TOC percentage ranged from 0.03 - 4.02 %. In the mean time, the statistical analysis by Pearson correlation showed a positive correlation with coefficient, r = 0.790 which showing the TPH concentrations significantly have influence on the TOC accumulations in the surface sediment. (author)

  13. Storage and stability of biochar-derived carbon and total organic carbon in relation to minerals in an acid forest soil of the Spanish Atlantic area.

    Science.gov (United States)

    Fernández-Ugalde, Oihane; Gartzia-Bengoetxea, Nahia; Arostegi, Javier; Moragues, Lur; Arias-González, Ander

    2017-06-01

    Biochar can largely contribute to enhance organic carbon (OC) stocks in soil and improve soil quality in forest and agricultural lands. Its contribution depends on its recalcitrance, but also on its interactions with minerals and other organic compounds in soil. Thus, it is important to study the link between minerals, natural organic matter and biochar in soil. In this study, we investigated the incorporation of biochar-derived carbon (biochar-C) into various particle-size fractions with contrasting mineralogy and the effect of biochar on the storage of total OC in the particle-size fractions in an acid loamy soil under Pinus radiata (C3 type) in the Spanish Atlantic area. We compared plots amended with biochar produced from Miscanthus sp. (C4 type) with control plots (not amended). We separated sand-, silt-, and clay-size fractions in samples collected from 0 to 20-cm depth. In each fraction, we analyzed clay minerals, metallic oxides and oxy-hydroxides, total OC and biochar-C. The results showed that 51% of the biochar-C was in fractions fractions (0.2-2μm, 0.05-0.2μm, fractions, as it occurred with the vermiculitic phases and metallic oxides and oxy-hydroxides. Biochar also affected to the distribution of total OC among particle-size fractions. Total OC concentration was greater in fractions 2-20μm, 0.2-2μm, 0.05-0.2μm in biochar-amended plots than in control plots. This may be explained by the adsorption of dissolved OC from fraction organic matter already occurred in the first year. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. A new method of body habitus correction for total body potassium measurements

    International Nuclear Information System (INIS)

    O'Hehir, S; Green, S; Beddoe, A H

    2006-01-01

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use

  15. Hydrogen production by the iodine-sulphur thermochemical cycle. Total and partial pressure measurements

    International Nuclear Information System (INIS)

    D Doizi; V Dauvois; J L Roujou; V Delanne; P Fauvet; B Larousse; O Hercher; P Carles; C Moulin

    2006-01-01

    The iodine sulphur thermochemical cycle appears to be one of the most promising candidate for the massive production of hydrogen using nuclear energy. The key step in this cycle is the HI distillation section which must be optimized to get a good efficiency of the overall cycle. The concept of reactive versus extractive distillation of HI has been proposed because of its potentiality. The design and the optimization of the reactive distillation column requires the knowledge of the liquid vapour equilibrium over the ternary HI-I 2 -H 2 O mixtures up to 300 C and 100 bars. A general methodology based on three experimental devices imposed by the very corrosive and concentrated media will be described: 1) I1 for the total pressure measurement versus different ternary compositions. 2) I2 for the partial and total pressure measurements around 130 C and 2 bars to validate the choice of the analytical optical 'online' techniques we have proposed. 3) I3 for the partial and total pressures measurements in the process domain. The results obtained on pure samples, binary mixtures HI-H 2 O and ternary mixtures using an experimental design analysis in the experimental device I2 will be discussed. (authors)

  16. A new method of body habitus correction for total body potassium measurements

    Energy Technology Data Exchange (ETDEWEB)

    O' Hehir, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Green, S [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom); Beddoe, A H [University Hospital Birmingham Foundation NHS Trust, Birmingham (United Kingdom)

    2006-09-07

    This paper describes an accurate and time-efficient method for the determination of total body potassium via a combination of measurements in the Birmingham whole body counter and the use of the Monte Carlo n-particle (MCNP) simulation code. In developing this method, MCNP has also been used to derive values for some components of the total measurement uncertainty which are difficult to quantify experimentally. A method is proposed for MCNP-assessed body habitus corrections based on a simple generic anthropomorphic model, scaled for individual height and weight. The use of this model increases patient comfort by reducing the need for comprehensive anthropomorphic measurements. The analysis shows that the total uncertainty in potassium weight determination by this whole body counting methodology for water-filled phantoms with a known amount of potassium is 2.7% (SD). The uncertainty in the method of body habitus correction (applicable also to phantom-based methods) is 1.5% (SD). It is concluded that this new strategy provides a sufficiently accurate model for routine clinical use.

  17. Measurements of flux and isotopic composition of soil carbon dioxide

    International Nuclear Information System (INIS)

    Gorczyca, Z.; Rozanski, K.; Kuc, T.

    2002-01-01

    The flux and isotope composition of soil CO 2 has been regularly measured at three sites located in the southern Poland, during the time period: January 1998 - October 2000. They represent typical ecosystems appearing in central Europe: (i) mixed forest; (ii) cultivated agricultural field; (iii) grassland. To monitor the flux and isotopic composition of soil CO 2 , a method based on the inverted cup principle was adopted. The flux of soil CO 2 reveals distinct seasonal fluctuations, with maximum values up to ca. 25 mmol/m 2 /h during sommer months and around ten times lower values during winter time. Also significant differences among the monitored sites were detected, the flux density of this gas being highest for the mixed forest site and ca. two times lower for the cultivated grassland. Carbon-13 content of the soil CO 2 reveals little seasonal variability, with δ 13 C values essentially reflecting the isotopic composition of the soil organic matter and the vegetation type. The carbon-14 content of soil CO 2 flux also reveals slight seasonality, with lower δ 14 C values recorded during winter time. Significantly lower δ 14 C values recorded during winter time. Significantly lower δ 14 C values were recorded at depth. (author)

  18. The measurement of dissolved and gaseous carbon dioxide concentration

    Science.gov (United States)

    Zosel, J.; Oelßner, W.; Decker, M.; Gerlach, G.; Guth, U.

    2011-07-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO2. In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements.

  19. The measurement of dissolved and gaseous carbon dioxide concentration

    International Nuclear Information System (INIS)

    Zosel, J; Oelßner, W; Decker, M; Gerlach, G; Guth, U

    2011-01-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO 2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO 2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO 2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO 2 . In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements. (topical review)

  20. High nitrate to phosphorus regime attenuates negative effects of rising pCO2 on total population carbon accumulation

    Directory of Open Access Journals (Sweden)

    S. A. Krug

    2012-03-01

    Full Text Available The ongoing rise in atmospheric pCO2 and consequent increase in ocean acidification have direct effects on marine calcifying phytoplankton, which potentially alters carbon export. To date it remains unclear, firstly, how nutrient regime, in particular by coccolithophores preferred phosphate limitation, interacts with pCO2 on particulate carbon accumulation; secondly, how direct physiological responses on the cellular level translate into total population response. In this study, cultures of Emiliania huxleyi were full-factorially exposed to two different N:P regimes and three different pCO2 levels. Cellular biovolume and PIC and POC content significantly declined in response to pCO2 in both nutrient regimes. Cellular PON content significantly increased in the Redfield treatment and decreased in the high N:P regime. Cell abundance significantly declined in the Redfield and remained constant in the high N:P regime. We hypothesise that in the high N:P regime severe phosphorous limitation could be compensated either by reduced inorganic phosphorous demand and/or by enzymatic uptake of organic phosphorous. In the Redfield regime we suggest that enzymatic phosphorous uptake to supplement enhanced phosphorous demand with pCO2 was not possible and thus cell abundance declined. These hypothesised different physiological responses of E. huxleyi among the nutrient regimes significantly altered population carrying capacities along the pCO2 gradient. This ultimately led to the attenuated total population response in POC and PIC content and biovolume to increased pCO2 in the high N:P regime. Our results point to the fact that the physiological (i.e. cellular PIC and POC response to ocean acidification cannot be linearly extrapolated to total population response and thus carbon export. It is therefore necessary to consider both effects of nutrient limitation on cell physiology and their consequences for population size when predicting the influence of

  1. Strain measurement in concrete using embedded carbon roving-based sensors

    International Nuclear Information System (INIS)

    Quadflieg, Till; Gries, Thomas; Stolyarov, Oleg

    2016-01-01

    This paper presents the results of the application of carbon rovings as strain sensors for measuring the strain in concrete. In this work, three types of electrically conductive carbon roving with different characteristics were used. The possibility of using carbon rovings as a strain sensor is demonstrated via measurements in tensile and four point bending tests. The experimental setups and methods for measuring the electrical resistance of carbon roving in the roving and concrete are described. The results of the characterization of the electrical behavior as a function of strain of carbon rovings and concrete are presented and discussed. The obtained results indicate that the strain range of carbon rovings optimally corresponds to the strain range of concrete. This characteristic behavior makes the carbon rovings well suited for the use as strain sensors. A good correlation has been found between the electrical resistance-strain curve of the carbon roving and the measurements in the concrete.

  2. Net ecosystem carbon dioxide exchange in tropical rainforests - sensitivity to environmental drivers and flux measurement methodology

    Science.gov (United States)

    Fu, Z.; Stoy, P. C.

    2017-12-01

    Tropical rainforests play a central role in the Earth system services of carbon metabolism, climate regulation, biodiversity maintenance, and more. They are under threat by direct anthropogenic effects including deforestation and indirect anthropogenic effects including climate change. A synthesis of the factors that determine the net ecosystem exchange of carbon dioxide (NEE) across multiple time scales in different tropical rainforests has not been undertaken to date. Here, we study NEE and its components, gross primary productivity (GPP) and ecosystem respiration (RE), across thirteen tropical rainforest research sites with 63 total site-years of eddy covariance data. Results reveal that the five ecosystems that have greater carbon uptakes (with the magnitude of GPP greater than 3000 g C m-2 y-1) sequester less carbon - or even lose it - on an annual basis at the ecosystem scale. This counterintuitive result is because high GPP is compensated by similar magnitudes of RE. Sites that provided subcanopy CO2 storage observations had higher average magnitudes of GPP and RE and consequently lower NEE, highlighting the importance of measurement methodology for understanding carbon dynamics in tropical rainforests. Vapor pressure deficit (VPD) constrained GPP at all sites, but to differing degrees. Many environmental variables are significantly related to NEE at time scales greater than one year, and NEE at a rainforest in Malaysia is significantly related to soil moisture variability at seasonal time scales. Climate projections from 13 general circulation models (CMIP5) under representative concentration pathway (RCP) 8.5 suggest that many current tropical rainforest sites on the cooler end of the current temperature range are likely to reach a climate space similar to present-day warmer sites by the year 2050, and warmer sites will reach a climate space not currently experienced. Results demonstrate the need to quantify if mature tropical trees acclimate to heat and

  3. Single-slice epicardial fat area measurement. Do we need to measure the total epicardial fat volume?

    International Nuclear Information System (INIS)

    Oyama, Noriko; Goto, Daisuke; Ito, Yoichi M.

    2011-01-01

    The aim of this study was to assess a method for measuring epicardial fat volume (EFV) by means of a single-slice area measurement. We investigated the relation between a single-slice fat area measurement and total EFV. A series of 72 consecutive patients (ages 65±11 years; 36 men) who had undergone cardiac computed tomography (CT) on a 64-slice multidetector scanner with prospective electrocardiographic triggering were retrospectively reviewed. Pixels in the pericardium with a density range from -230 to -30 Hounsfield units were considered fat, giving the per-slice epicardial fat area (EFA). The EFV was estimated by the summation of EFAs multiplied by the slice thickness. We investigated the relation between total EFV and each EFA. EFAs measured at several anatomical landmarks - right pulmonary artery, origins of the left main coronary artery, right coronary artery, coronary sinus - all correlated with the EFV (r=0.77-0.92). The EFA at the LMCA level was highly reproducible and showed an excellent correlation with the EFV (r=0.92). The EFA is significantly correlated with the EFV. The EFA is a simple, quick method for representing the time-consuming EFV, which has been used as a predictive indicator of cardiovascular diseases. (author)

  4. Developing SyrinOX total antioxidant capacity assay for measuring antioxidants in humans.

    Science.gov (United States)

    Prasetyo, Endry N; Knes, Otto; Nyanhongo, Gibson S; Guebitz, Georg M

    2013-02-01

    Accurate monitoring of the antioxidant status or of oxidative stress in patients is still a big challenge in clinical laboratories. This study investigates the possibility of applying a newly developed total antioxidant capacity assay method based on laccase or peroxidase oxidized syringaldazine [Tetramethoxy azobismethylene quinone (TMAMQ)] which is referred to here as SyrinOX, as a diagnostic tool for monitoring both oxidative stress and antioxidant status in patients. Attempts to adapt the Randox total antioxidant procedure [simultaneous incubation of the radical generating system (metmyoglobin and H(2) O(2) ) and antioxidant sample] for SyrinOX were abandoned after it was discovered that the H(2) O(2) reacted with enzymatically generated TMAMQ and ABTS radicals at a rate of 6.4 × 10(-2) /μM/s and 5.7 × 10(-3) /μM/s respectively. Thus this study for the first time demonstrates the negative effects of H(2) O(2) in the Randox system. This leads to erroneous results because the total antioxidant values obtained are the sum of radicals reduced by antioxidants plus those reacting with the radical generating system. Therefore they should be avoided not only for this particular method but also when using other similar methods. Consequently, SyrinOX is best applied using a three-step approach involving, production of TMAMQ, recovery and purification (free from enzyme and other impurities) and then using TMAMQ for measuring the total antioxidant capacity of samples. Using this approach, the reaction conditions for application of SyrinOX when measuring the total antioxidant capacity of plasma sample were determined to be 50% (v/v) ethanol/50 mM sodium succinate buffer pH 5.5, between 20 and 25 °C for at least 1 h. © 2012 The Authors. International Journal of Experimental Pathology © 2012 International Journal of Experimental Pathology.

  5. Method for in situ carbon deposition measurement for solid oxide fuel cells

    Science.gov (United States)

    Kuhn, J.; Kesler, O.

    2014-01-01

    Previous methods to measure carbon deposition in solid oxide fuel cell (SOFC) anodes do not permit simultaneous electrochemical measurements. Electrochemical measurements supplemented with carbon deposition quantities create the opportunity to further understand how carbon affects SOFC performance and electrochemical impedance spectra (EIS). In this work, a method for measuring carbon in situ, named here as the quantification of gasified carbon (QGC), was developed. TGA experiments showed that carbon with a 100 h residence time in the SOFC was >99.8% gasified. Comparison of carbon mass measurements between the TGA and QGC show good agreement. In situ measurements of carbon deposition in SOFCs at varying molar steam/carbon ratios were performed to further validate the QGC method, and suppression of carbon deposition with increasing steam concentration was observed, in agreement with previous studies. The technique can be used to investigate in situ carbon deposition and gasification behavior simultaneously with electrochemical measurements for a variety of fuels and operating conditions, such as determining conditions under which incipient carbon deposition is reversible.

  6. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  7. Measurement of neutron total cross-sections for {sup nat}Dy at Pohang Neutron Facility

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S. G.; Kye, Y. U.; Shvetsov, Valery; Cho, M. H. [POSTECH, Pohang (Korea, Republic of); Namkung, W.; Cho, M. H. [Pohang Accelerator Laboratory, Pohang (Korea, Republic of); Kim, G. N. [Kyungpook National Univ., Daegu (Korea, Republic of); Lee, M. W. [Dongnam Inst. of radiological and Medical Science, Busan (Korea, Republic of)

    2013-05-15

    There are few measurements for Dy below 100 eV. Moreover, there exist discrepancies among the measurements. In the present work, the total neutron cross-sections for {sup nat}Dy were measured by using the time-of-flight (TOF) method at the Pohang Neutron Facility (PNF). The PNF consists of an electron linac, a water-cooled Ta target, and an 11-m-long TOF path. The characteristics of PNF are described elsewhere. We also briefly discuss the future plan to verify our experimental result. We have measured the total neutron cross-sections of {sup nat}Dy in the neutron energy region from 0.1 eV to 100 eV with the TOF method at the Po hang Neutron Facility. The present result is in good agreement with the previous data and the evaluated data in ENDF/B-VI. We would like to get resonance parameters by using SAMMY or REFIT codes.

  8. A comparison between two methods of measuring total fat in the Iranian soldiers

    Directory of Open Access Journals (Sweden)

    J. Rahmani

    2017-04-01

    Full Text Available Background: Constant checkup and control of body fat mass is an important parameter for the health and efficiency of individuals in any society. This parameter is especially crucial in army soldiers since physical fitness is a key role in reaching high physical performance, health, and survival in war. Objective: This study was designed to compare two methods of measuring fat, the method of circumference-based military equations (CBEs to estimate body fat mass compared to the method of skinfold thickness-based equation (SBE in Iranian soldiers. Methods: This cross-sectional study was conducted on 246 Iranian soldiers were recruited in Tehran (2016. Height, waist, and neck circumference were measured and the total body fat mass was calculated using CBEs. Then, the results of using Pierson’s correlation and Bland-Altman methods were compared with Jackson and Pollock’s skinfold thickness measurement. Findings: The total body fat mass of the soldiers using CBEs was 18.94±6.30% and using Jakson and Pollock’s skinfold thickness formula was 17.43±4.45%. The correlation between the two methods was r=0.984 and SEE was 1.1% (P<0.001. Conclusion: The more body fat makes the error waist circumference greater. The error is so much that don’t use this method to measure fat.

  9. Development and calibration of an accurate 6-degree-of-freedom measurement system with total station

    International Nuclear Information System (INIS)

    Gao, Yang; Lin, Jiarui; Yang, Linghui; Zhu, Jigui

    2016-01-01

    To meet the demand of high-accuracy, long-range and portable use in large-scale metrology for pose measurement, this paper develops a 6-degree-of-freedom (6-DOF) measurement system based on total station by utilizing its advantages of long range and relative high accuracy. The cooperative target sensor, which is mainly composed of a pinhole prism, an industrial lens, a camera and a biaxial inclinometer, is designed to be portable in use. Subsequently, a precise mathematical model is proposed from the input variables observed by total station, imaging system and inclinometer to the output six pose variables. The model must be calibrated in two levels: the intrinsic parameters of imaging system, and the rotation matrix between coordinate systems of the camera and the inclinometer. Then corresponding approaches are presented. For the first level, we introduce a precise two-axis rotary table as a calibration reference. And for the second level, we propose a calibration method by varying the pose of a rigid body with the target sensor and a reference prism on it. Finally, through simulations and various experiments, the feasibilities of the measurement model and calibration methods are validated, and the measurement accuracy of the system is evaluated. (paper)

  10. Measurement of carbon dioxide fluxes in a free-air carbon dioxide enrichment experiment using the closed flux chamber technique

    DEFF Research Database (Denmark)

    Selsted, Merete Bang; Ambus, Per; Michelsen, Anders

    2011-01-01

    Carbon dioxide (CO2) fluxes, composing net ecosystem exchange (NEE), ecosystem respiration (ER), and soil respiration (SR) were measured in a temperate heathland exposed to elevated CO2 by the FACE (free-air carbon enrichment) technique, raising the atmospheric CO2 concentration from c. 380 μmol...

  11. Anaesthesia for laparoscopic nephrectomy: Does end-tidal carbon dioxide measurement correlate with arterial carbon dioxide measurement?

    Science.gov (United States)

    Jayan, Nithin; Jacob, Jaya Susan; Mathew, Mohan

    2018-04-01

    Not many studies have explored the correlation between arterial carbon dioxide tension (PaCO 2 ) and end-tidal carbon dioxide tension (ETCO 2 ) in surgeries requiring pneumoperitoneum of more than 1 hour duration with the patient in non-supine position. The aim of our study was to evaluate the correlation of ETCO 2 with PaCO 2 in patients undergoing laparoscopic nephrectomy under general anaesthesia. A descriptive study was performed in thirty patients undergoing laparoscopic nephrectomy from September 2014 to August 2015. The haemodynamic parameters, minute ventilation, PaCO 2 and ETCO 2 measured at three predetermined points during the procedure were analysed. Correlation was checked using Pearson's Correlation Coefficient Test. P <0.05 was considered statistically significant. Statistical analysis of the values showed a positive correlation between ETCO 2 and PaCO 2 ( P < 0.05). Following carbon dioxide insufflation, both ETCO 2 and PaCO 2 increased by 5.4 and 6.63 mmHg, respectively, at the end of the 1 st hour. The PaCO 2 -ETCO 2 gradient was found to increase during the 1 st hour following insufflation (4.07 ± 2.05 mmHg); it returned to the pre-insufflation values in another hour (2.93 ± 1.43 mmHg). Continuous ETCO 2 monitoring is a reliable indicator of the trend in arterial CO 2 fluctuations in the American Society of Anesthesiologists Grades 1 and 2 patients undergoing laparoscopic nephrectomy under general anaesthesia.

  12. Superresolution confocal technology for displacement measurements based on total internal reflection.

    Science.gov (United States)

    Kuang, Cuifang; Ali, M Yakut; Hao, Xiang; Wang, Tingting; Liu, Xu

    2010-10-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  13. Superresolution confocal technology for displacement measurements based on total internal reflection

    International Nuclear Information System (INIS)

    Kuang Cuifang; Hao Xiang; Wang Tingting; Liu Xu; Ali, M. Yakut

    2010-01-01

    In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

  14. Measurement of the polarized neutron---polarized 3He total cross section

    International Nuclear Information System (INIS)

    Keith, C.D.; Gould, C.R.; Haase, D.G.; Seely, M.L.; Huffman, P.R.; Roberson, N.R.; Tornow, W.; Wilburn, W.S.

    1995-01-01

    The first measurements of polarized neutron--polarized 3 He scattering in the few MeV energy region are reported. The total cross section difference Δσ T for transversely polarized target and beam has been measured for neutron energies between 1.9 and 7.5 MeV. Comparison is made to predictions of Δσ T using various descriptions of the 4 He continuum. A brute-force polarized target of solid 3 He has been developed for these measurements. The target is 4.3x10 22 atoms/cm 2 thick and is polarized to 38% at 7 Telsa and 12 mK. copyright 1995 American Institute of Physics

  15. Hospital-Based Acute Care After Total Hip and Knee Arthroplasty: Implications for Quality Measurement.

    Science.gov (United States)

    Trimba, Roman; Laughlin, Richard T; Krishnamurthy, Anil; Ross, Joseph S; Fox, Justin P

    2016-03-01

    Although hospital readmissions are being adopted as a quality measure after total hip or knee arthroplasty, they may fail accurately capture the patient's postdischarge experience. We studied 272,853 discharges from 517 hospitals to determine hospital emergency department (ED) visit and readmission rates. The hospital-level, 30-day, risk-standardized ED visit (median = 5.6% [2.4%-13.7%]) and hospital readmission (5.0% [2.6%-9.2%]) rates were similar and varied widely. A hospital's risk-standardized ED visit rate did not correlate with its readmission rate (r = -0.03, P = .50). If ED visits were included in a broader "readmission" measure, 246 (47.6%) hospitals would change perceived performance groups. Including ED visits in a broader, hospital-based, acute care measure may be warranted to better describe postdischarge health care utilization. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Measurements of Carbon Dioxide, Carbon Monoxide, and Other Related Tracers at High Spatial and Temporal Resolution in an Urban Environment

    Science.gov (United States)

    Rella, C.; Jacobson, G.

    2012-04-01

    The ability to quantify the sources and sinks of carbon dioxide on the urban scale is essential for understanding the atmospheric drivers to global climate change. In the 'top-down' approach, overall carbon fluxes are determined by combining remote measurements of carbon dioxide concentrations with complex atmospheric transport models, and these emissions measurements are compared to "bottoms-up" predictions based on detailed inventories of the sources and sinks of carbon, both anthropogenic and biogenic in nature. This approach, which has been proven to be effective at continental scales, becomes challenging to implement at the urban scale, due to poorly understood micrometeorological atmospheric transport models and high variability of the emissions sources in space (e.g., factories, highways, residences) and time (rush hours, factory shifts and shutdowns, residential energy usage variability during the day and over the year). New measurement and analysis techniques are required to make sense of the carbon dioxide signal in cities. Here we present detailed, high spatial- and temporal-resolution greenhouse gas measurements in Silicon Valley in California. The synthesis of two experimental campaigns is presented: real-time measurements from two ten-meter urban 'towers,' and ground-based mobile mapping measurements. Real-time carbon dioxide data from a nine-month period are combined with real-time carbon monoxide, methane, acetylene, and carbon 13 measurements to partition the observed CO2 concentrations between different anthropogenic sectors (e.g., transport, residential) and biogenic sources. The carbon monoxide to carbon dioxide ratio is shown to vary over more than a factor of two from season to season or even from day to night, indicating rapid and frequent shifts in the balance between different carbon dioxide sources. Clear differences are seen between the two urban sites, which are separated by 7 km. Further information is given by the carbon 13 signature

  17. Six years of total ozone column measurements from SCIAMACHY nadir observations

    Science.gov (United States)

    Lerot, C.; van Roozendael, M.; van Geffen, J.; van Gent, J.; Fayt, C.; Spurr, R.; Lichtenberg, G.; von Bargen, A.

    2009-04-01

    Total O3 columns have been retrieved from six years of SCIAMACHY nadir UV radiance measurements using SDOAS, an adaptation of the GDOAS algorithm previously developed at BIRA-IASB for the GOME instrument. GDOAS and SDOAS have been implemented by the German Aerospace Center (DLR) in the version 4 of the GOME Data Processor (GDP) and in version 3 of the SCIAMACHY Ground Processor (SGP), respectively. The processors are being run at the DLR processing centre on behalf of the European Space Agency (ESA). We first focus on the description of the SDOAS algorithm with particular attention to the impact of uncertainties on the reference O3 absorption cross-sections. Second, the resulting SCIAMACHY total ozone data set is globally evaluated through large-scale comparisons with results from GOME and OMI as well as with ground-based correlative measurements. The various total ozone data sets are found to agree within 2% on average. However, a negative trend of 0.2-0.4%/year has been identified in the SCIAMACHY O3 columns; this probably originates from instrumental degradation effects that have not yet been fully characterized.

  18. Six years of total ozone column measurements from SCIAMACHY nadir observations

    Directory of Open Access Journals (Sweden)

    G. Lichtenberg

    2009-04-01

    Full Text Available Total O3 columns have been retrieved from six years of SCIAMACHY nadir UV radiance measurements using SDOAS, an adaptation of the GDOAS algorithm previously developed at BIRA-IASB for the GOME instrument. GDOAS and SDOAS have been implemented by the German Aerospace Center (DLR in the version 4 of the GOME Data Processor (GDP and in version 3 of the SCIAMACHY Ground Processor (SGP, respectively. The processors are being run at the DLR processing centre on behalf of the European Space Agency (ESA. We first focus on the description of the SDOAS algorithm with particular attention to the impact of uncertainties on the reference O3 absorption cross-sections. Second, the resulting SCIAMACHY total ozone data set is globally evaluated through large-scale comparisons with results from GOME and OMI as well as with ground-based correlative measurements. The various total ozone data sets are found to agree within 2% on average. However, a negative trend of 0.2–0.4%/year has been identified in the SCIAMACHY O3 columns; this probably originates from instrumental degradation effects that have not yet been fully characterized.

  19. Measurement of total body chlorine by prompt gamma in vivo neutron activation analysis

    International Nuclear Information System (INIS)

    Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1987-01-01

    A method of measuring total body chlorine (TBCl) by prompt gamma in vivo neutron activation analysis is described depending on the same NaI(Tl) spectra used for determinations of total body nitrogen. Ratios of chlorine to hydrogen are derived and TBCl determined using a model of body composition depending on measured body weight, total body water (by tritium dilution) and protein (6.25 x nitrogen) as well as estimated body minerals and glycogen. The precision of the method based on scanning an anthropomorphic phantom is approximately 9% (SD), for a patient dose equivalent of less than 0.30 mSv. Spectra collected from 67 normal volunteers (32 male, 35 female) yielded mean values of TBCl of 72 +- 19 (SD) g in males and 53.6 +- 15 g in females, in broad agreement with values reported by workers using delayed gamma methods. Results are presented for two human cadavers analysed by neutron activation and conventional chemical analysis; the ratios of TBCl (neutron activation) to TBCl (chemical) were 0.980 +- 0.028 (SEM) and 0.91 +- 0.09. It is suggested that an improvement in precision will be achieved by increasing the scanning time (thereby increasing the radiation dose equivalent) and by adding two more detectors. (author)

  20. Measurement of the total antioxidant potential in chronic obstructive pulmonary diseases with a novel automated method

    International Nuclear Information System (INIS)

    Ceylan, E.; Gencer, M.; Uzer, E.; Celik, H.

    2007-01-01

    To determine the oxidative and antioxidative status of plasma of patients with chronic obstructive pulmonary disease (COPD) and to compare these values with healthy smokers and healthy non-smokers control subjects using a more recently developed automated measurement method. This study involved 40 COPD patients, 25 healthy smokers, and 25 non-healthy smokers who attended the Chest Disease Outpatient Clinic in Harran University Research Hospital, Turkey between the period March 2006 and June 2006. We calculated the total antioxidant potential (TAOP) to determine the antioxidative status of plasma and we measured the total peroxide levels to determine the oxidative status of plasma. The TAOP of plasma was significantly lower in patients with COPD than in healthy smokers and healthy non-smokers (p< 0.001). In contrast, the mean total peroxide level of plasma was significantly higher in COPD patients than in healthy smokers and healthy non-smokers (p<0.001). We found a decreased in TAOP COPD patients using a simple, rapid and reliably automated colorimetric assay, which may suitable for use in routine clinical biochemistry laboratory and considerably facilitates the assessment of this useful clinical parameter. We suggest that this novel method may be used as a routine test to evaluate and follow-up the levels of oxidative stress in COPD. (author)

  1. Measurement of the Antiproton-Proton Total Cross-Section at the CERN ISR

    CERN Multimedia

    2002-01-01

    This experiment is a measurement of small angle scattering of antiprotons on protons and of protons on protons at 15/15, 22/22, 26/26 and 31/31 GeV, with the aim of obtaining data on the total cross-section for the scattering of protons on protons, and of determining the ratio of the real to the imaginary scattering amplitude at zero momentum transfer for antiprotons on protons. The measurement is divided into two parts: \\item 1) The measurement of @s^t^o^t(@*p) and @s^t^o^t(pp), using hodoscopes placed at small angles, outside the vacuum pipe, at approximately 9 metres from the intersection point. \\item 2) The measurement of the region in !t!, the momentum transfer squared, around the value !t^c!, where Coulomb and nuclear scattering are equal, in order to deduce the quantity @r = Re f(t=0)/Im f(t=0). This latter measurement is done by employi in earlier @s^t(pp) and @r experiments at the ISR. \\end{enumerate} In both set-ups the measurements are made by recording coincidences between collinear counters in th...

  2. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  3. Quantitative comparisons between experimentally measured 2-D carbon radiation and Monte Carlo impurity (MCI) code simulations

    International Nuclear Information System (INIS)

    Evans, T.E.; Leonard, A.W.; West, W.P.; Finkenthal, D.F.; Fenstermacher, M.E.; Porter, G.D.

    1998-08-01

    Experimentally measured carbon line emissions and total radiated power distributions from the DIII-D divertor and Scrape-Off Layer (SOL) are compared to those calculated with the Monte Carlo Impurity (MCI) model. A UEDGE background plasma is used in MCI with the Roth and Garcia-Rosales (RG-R) chemical sputtering model and/or one of six physical sputtering models. While results from these simulations do not reproduce all of the features seen in the experimentally measured radiation patterns, the total radiated power calculated in MCI is in relatively good agreement with that measured by the DIII-D bolometric system when the Smith78 physical sputtering model is coupled to RG-R chemical sputtering in an unaltered UEDGE plasma. Alternatively, MCI simulations done with UEDGE background ion temperatures along the divertor target plates adjusted to better match those measured in the experiment resulted in three physical sputtering models which when coupled to the RG-R model gave a total radiated power that was within 10% of measured value

  4. Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments

    Science.gov (United States)

    Olson, David A.; Norris, Gary A.

    Experiments were completed to determine the extent of artifacts from sampling elemental carbon (EC) and organic carbon (OC) under sample conditions consistent with personal sampling. Two different types of experiments were completed; the first examined possible artifacts from oils used in personal environmental monitor (PEM) impactor plates, and the second examined artifacts from microenvironmental sampling using different sampling media combinations (quartz, Teflon, XAD denuder, and electrostatic precipitator). The effectiveness of front and backup filters was evaluated for most sampling configurations. Mean total carbon concentrations from sampling configurations using impactor oils were not statistically different from the control case (using a sharp cut cyclone). Three microenvironments were tested (kitchen, library, and ambient); carbon concentrations were highest in the kitchen using a front quartz filter (mean OC of 16.4 μg m -3). The lowest front quartz filter concentrations were measured in the library using XAD denuders (mean OC of 3.6 μg m -3). Denuder removal efficiencies (average of 82% for total carbon) were lower compared with previous ambient studies and may indicate that indoor sources influenced denuder efficiency during sample collection. The highest carbon concentrations from backup quartz filters were measured using the Teflon-quartz combination.

  5. Proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.H.; Kycia, T.F.

    1978-03-01

    A PWC system was developed and extensively used in precision measurements of total cross sections at low momenta (0.4 to 1.1 GeV/c) and at high momenta (23 to 370 GeV/c). This ''electronic collimator'' operated simultaneously in a fast (250 nsec) decision making mode, and a slower (0.5 msec) readout mode. The decision making mode utilized adjustable hard-wired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events were read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure

  6. A proportional wire chamber system for beam definition in precision total cross section measurements

    International Nuclear Information System (INIS)

    Carroll, A.S.; Chiang, I.-H.; Kycia, T.F.; Li, K.K.; Mazur, P.O.; Michael, D.N.; Mockett, P.M.; Rahm, D.C.; Rubinstein, R.; Eartly, D.P.; Wehmann, A.A.

    1978-01-01

    The authors have developed and extensively used a PWC system in precision measurements of total cross sections at low momenta (0.4-1.1 GeV/c) and at high momenta (23-370 GeV/c). This 'electronic collimator' operated simultaneously in a fast (250 ns) decision making mode, and a slower (0.5 ms) readout mode. The decision making mode utilized adjustable hardwired logic to define acceptable incident beam trajectories and reject multiple beam tracks. A sample of the events was read into an on-line computer for beam tuning, for chamber diagnostics, and for study of the effect of small angle scattering to verify the total cross section extrapolation procedure. (Auth.)

  7. Measurement of the $Z/A$ dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topaksu, A; Van Dantzig, R; De Jong, M; Konijn, J; Melzer, O; Oldeman, R G C; Pesen, E; Van der Poel, C A F J; Spada, F R; Visschers, J L; Güler, M; Serin-Zeyrek, M; Kama, S; Sever, R; Tolun, P; Zeyrek, M T; Armenise, N; Catanesi, M G; De Serio, M; Ieva, M; Muciaccia, M T; Radicioni, E; Simone, S; Bülte, A; Winter, Klaus; El-Aidi, R; Van de Vyver, B; Vilian, P; Wilquet, G; Saitta, B; Di Capua, E; Ogawa, S; Shibuya, H; Artamonov, A V; Brunner, J; Chizhov, M; Cussans, D G; Doucet, M; Fabre, Jean-Paul; Hristova, I R; Kawamura, T; Kolev, D; Litmaath, M; Meinhard, H; Panman, J; Papadopoulos, I M; Ricciardi, S; Rozanov, A; Saltzberg, D; Tsenov, R V; Uiterwijk, J W E; Zucchelli, P; Goldberg, J; Chikawa, M; Arik, E; Song, J S; Yoon, C S; Kodama, K; Ushida, N; Aoki, S; Hara, T; Delbar, T; Favart, D; Grégoire, G; Kalinin, S; Makhlyoueva, I V; Gorbunov, P; Khovanskii, V D; Shamanov, V V; Tsukerman, I; Bruski, N; Frekers, D; Rondeshagen, D; Wolff, T; Hoshino, K; Kawada, J; Komatsu, M; Miyanishi, M; Nakamura, M; Nakano, T; Narita, K; Niu, K; Niwa, K; Nonaka, N; Sato, O; Toshito, T; Buontempo, S; Cocco, A G; D'Ambrosio, N; De Lellis, G; De Rosa, G; Di Capua, F; Ereditato, A; Fiorillo, G; Marotta, A; Messina, M; Migliozzi, P; Pistillo, C; Santorelli, R; Scotto-Lavina, L; Strolin, P; Tioukov, V; Nakamura, K; Okusawa, T; Dore, U; Loverre, P F; Ludovici, L; Maslennikov, A L; Righini, P; Rosa, G; Santacesaria, R; Satta, A; Barbuto, E; Bozza, C; Grella, G; Romano, G; Sirignano, C; Sorrentino, S; Sato, Y; Tezuka, I

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu_mu + N -> mu^- + X. The targets, passive blocks of ~100kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematics effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio.

  8. Measurement of the Z/A dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topasku, A; Dantzig, R V

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu submu + N -> mu sup - + X. The targets, passive blocks of propor to 100 kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematic effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio. (orig.)

  9. Intra-Cavity Total Reflection For High Sensitivity Measurement Of Optical Properties

    Science.gov (United States)

    Pipino, Andrew Charles Rule

    1999-11-16

    An optical cavity resonator device is provided for conducting sensitive murement of optical absorption by matter in any state with diffraction-limited spatial resolution through utilization of total internal reflection within a high-Q (high quality, low loss) optical cavity. Intracavity total reflection generates an evanescent wave that decays exponentially in space at a point external to the cavity, thereby providing a localized region where absorbing materials can be sensitively probed through alteration of the Q-factor of the otherwise isolated cavity. When a laser pulse is injected into the cavity and passes through the evanescent state, an amplitude loss resulting from absorption is incurred that reduces the lifetime of the pulse in the cavity. By monitoring the decay of the injected pulse, the absorption coefficient of manner within the evanescent wave region is accurately obtained from the decay time measurement.

  10. An updated h-index measures both the primary and total scientific output of a researcher.

    Science.gov (United States)

    Bucur, Octavian; Almasan, Alex; Zubarev, Roman; Friedman, Mark; Nicolson, Garth L; Sumazin, Pavel; Leabu, Mircea; Nikolajczyk, Barbara S; Avram, Dorina; Kunej, Tanja; Calin, George A; Godwin, Andrew K; Adami, Hans-Olov; Zaphiropoulos, Peter G; Richardson, Des R; Schmitt-Ulms, Gerold; Westerblad, Håkan; Keniry, Megan; Grau, Georges E R; Carbonetto, Salvatore; Stan, Radu V; Popa-Wagner, Aurel; Takhar, Kasumov; Baron, Beverly W; Galardy, Paul J; Yang, Feng; Data, Dipak; Fadare, Oluwole; Yeo, Kt Jerry; Gabreanu, Georgiana R; Andrei, Stefan; Soare, Georgiana R; Nelson, Mark A; Liehn, Elisa A

    2015-01-01

    The growing interest in scientometry stems from ethical concerns related to the proper evaluation of scientific contributions of an author working in a hard science. In the absence of a consensus, institutions may use arbitrary methods for evaluating scientists for employment and promotion. There are several indices in use that attempt to establish the most appropriate and suggestive position of any scientist in the field he/she works in. A scientist's Hirsch-index (h-index) quantifies their total effective published output, but h-index summarizes the total value of their published work without regard to their contribution to each publication. Consequently, articles where the author was a primary contributor carry the same weight as articles where the author played a minor role. Thus, we propose an updated h-index named Hirsch(p,t)-index that informs about both total scientific output and output where the author played a primary role. Our measure, h(p,t) = h(p),h(t), is composed of the h-index h(t) and the h-index calculated for articles where the author was a key contributor; i.e. first/shared first or senior or corresponding author. Thus, a h(p,t) = 5,10 would mean that the author has 5 articles as first, shared first, senior or corresponding author with at least 5 citations each, and 10 total articles with at least 10 citations each. This index can be applied in biomedical disciplines and in all areas where the first and last position on an article are the most important. Although other indexes, such as r- and w-indexes, were proposed for measuring the authors output based on the position of researchers within the published articles, our simpler strategy uses the already established algorithms for h-index calculation and may be more practical to implement.

  11. Measurement of the elastic, total and diffraction cross sections at tevatron energies

    International Nuclear Information System (INIS)

    Belforte, S.

    1993-11-01

    The CDF collaboration has measured the differential elastic cross section dσ el /dt, the single diffraction dissociation double differential cross section d 2 σ sd /dM 2 dt and the total inelastic cross section for antiproton-proton collisions at center of mass energies √s = 546 and 1,800 GeV. Data for this measurement have been collected in short dedicated runs during the 1988--1989 data taking period of CDF. The elastic scattering slope is 15.28 ± 0.58 (16.98 ± 0.25) GeV -2 at √s = 546 (1,800) GeV. Using the luminosity independent method (1 + ρ 2 )σ T is measured to be 62.64 ± 0.95 (81.83 ± 2.29) mb at √s = 546 (1,800) GeV. Assuming ρ = 0.15 the elastic, total and single diffraction cross sections are σ el = 12.87 ± 0.30, σ T = 61.26 ± 0.93 and σ sd = 7.89 ± 0.33 mb (σ el = 19.70 ± 0.85, σ T = 80.03 ± 2.24 and σ sd = 9.46 ± 0.44 mb) at √s = 546 (1,800) GeV

  12. Comparisons of the Orbiting Carbon Observatory-2 (OCO-2 XCO2 measurements with TCCON

    Directory of Open Access Journals (Sweden)

    D. Wunch

    2017-06-01

    Full Text Available NASA's Orbiting Carbon Observatory-2 (OCO-2 has been measuring carbon dioxide column-averaged dry-air mole fraction, XCO2, in the Earth's atmosphere for over 2 years. In this paper, we describe the comparisons between the first major release of the OCO-2 retrieval algorithm (B7r and XCO2 from OCO-2's primary ground-based validation network: the Total Carbon Column Observing Network (TCCON. The OCO-2 XCO2 retrievals, after filtering and bias correction, agree well when aggregated around and coincident with TCCON data in nadir, glint, and target observation modes, with absolute median differences less than 0.4 ppm and RMS differences less than 1.5 ppm. After bias correction, residual biases remain. These biases appear to depend on latitude, surface properties, and scattering by aerosols. It is thus crucial to continue measurement comparisons with TCCON to monitor and evaluate the OCO-2 XCO2 data quality throughout its mission.

  13. Measurements of inelastic, elastic and total pp cross-sections at the LHC with ATLAS

    CERN Document Server

    Trottier-McDonald, Michel; The ATLAS collaboration

    2015-01-01

    First, a recent measurement of the inelastic cross section using the ATLAS detector with 63 $\\mu b^{−1}$ of proton-proton collisions at $\\sqrt{s}=13$ TeV is presented. The measurement is performed using scintillators mounted in front of the forward calorimeters. A cross section of $65.2\\pm0.8$ (exp.) $\\pm5.9$ (lum.) mb is measured in the fiducial region $M_X>13$ GeV, where $M_X$ is the larger of the dissociation masses of the two proton systems in diffractive events. The experimental uncertainty is indicated by (exp.) and the luminosity uncertainty by (lum.). The full inelastic cross section is determined to be $73.1\\pm0.9$ (exp.) $\\pm6.6$ (lum.) $\\pm3.8$ (extr.) mb, where (extr.) indicates model-dependent uncertainties on the extrapolation from the fiducial region. The measured value is about one standard deviation below most current theoretical predictions. Second, a measurement of the total $pp$ cross section at the LHC at $\\sqrt{s}=7$ TeV is presented. In a special run with high-$\\beta^*$ beam optics, a...

  14. Climate, soil texture, and soil types affect the contributions of fine-fraction-stabilized carbon to total soil organic carbon in different land uses across China.

    Science.gov (United States)

    Cai, Andong; Feng, Wenting; Zhang, Wenju; Xu, Minggang

    2016-05-01

    Mineral-associated organic carbon (MOC), that is stabilized by fine soil particles (i.e., silt plus clay, organic carbon (SOC) persistence and sequestration, due to its large contribution to total SOC (TSOC) and long turnover time. Our objectives were to investigate how climate, soil type, soil texture, and agricultural managements affect MOC contributions to TSOC in China. We created a dataset from 103 published papers, including 1106 data points pairing MOC and TSOC across three major land use types: cropland, grassland, and forest. Overall, the MOC/TSOC ratio ranged from 0.27 to 0.80 and varied significantly among soil groups in cropland, grassland, and forest. Croplands and forest exhibited significantly higher median MOC/TSOC ratios than in grassland. Moreover, forest and grassland soils in temperate regions had higher MOC/TSOC ratios than in subtropical regions. Furthermore, the MOC/TSOC ratio was much higher in ultisol, compared with the other soil types. Both the MOC content and MOC/TSOC ratio were positively correlated with the amount of fine fraction (silt plus clay) in soil, highlighting the importance of soil texture in stabilizing organic carbon across various climate zones. In cropland, different fertilization practices and land uses (e.g., upland, paddy, and upland-paddy rotation) significantly altered MOC/TSOC ratios, but not in cropping systems (e.g., mono- and double-cropping) characterized by climatic differences. This study demonstrates that the MOC/TSOC ratio is mainly driven by soil texture, soil types, and related climate and land uses, and thus the variations in MOC/TSOC ratios should be taken into account when quantitatively estimating soil C sequestration potential of silt plus clay particles on a large scale. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Measurement of defects in carbon fiber reinforced polymer drilled

    Directory of Open Access Journals (Sweden)

    Pascual Víctor

    2017-01-01

    Full Text Available Increasingly, fiber-reinforced materials are more widely used because of their good mechanical properties. It is usual to join pieces of these materials through screws and rivets, for which it is necessary to make a hole in the piece, usually by drilling. One of the problems of use CFRP resides in the appearance of defects due to the machining. The main defect to be taken into account is the delamination. Delamination implies poor tolerance when assembling parts, reducing the structural integrity of the part, and areas with high wear, as a series of stresses arise when mounting the screws. Much has been published about delamination and the factors that influence its appearance, so we are not going to focus on it. The present study aims to quantify and measure the defects associated with the drilling of compounds reinforced with carbon fibers, in relation to the cutting parameters used in each case. For this purpose, an optical measurement system and a posterior digital image processing will be used through Deltec Vision software.

  16. Measuring Method for Fuzz Mass of Carbon Fiber Tow

    Directory of Open Access Journals (Sweden)

    LI Tan

    2017-07-01

    Full Text Available In order to quantitatively test fuzz degree of carbon fiber (CF tow, a measuring method for fuzz mass of CF tow was developed, and the testing device was built. Fuzz mass of two kinds of domestic T800-grade CF were tested using the established method. The effects of spreading width of CF tow, tension and fuzz-adsorption material on the fuzz mass of the two fibers were investigated. Several kinds of imported, domestic T700-grade CF and T800-grade CF were tested using optimized testing conditions. The experimental results show that the testing method is easy to operate and has wide applicability. Under 1-2N tension, 0.1-0.6mm pore size of sponge and 1-4N load applied on sponge, the measured values of T800-grade CF with 12K yield are reasonable. For CF tow with high fuzz mass, certain spreading width makes fuzz inside fiber bundle expose, which is needed to ensure the accuracy of testing result.

  17. μTAS (micro total analysis systems) for the high-throughput measurement of nanomaterial solubility

    International Nuclear Information System (INIS)

    Tantra, R; Jarman, J

    2013-01-01

    There is a consensus in the nanoecotoxicology community that better analytical tools i.e. faster and more accurate ones, are needed for the physicochemical characterisation of nanomaterials in environmentally/biologically relevant media. In this study, we introduce the concept of μTAS (Micro Total Analysis Systems), which was a term coined to encapsulate the integration of laboratory processes on a single microchip. Our focus here is on the use of a capillary electrophoresis (CE) with conductivity detection microchip and how this may be used for the measurement of dissolution of metal oxide nanomaterials. Our preliminary results clearly show promise in that the device is able to: a) measure ionic zinc in various ecotox media with high selectivity b) track the dynamic dissolution events of zinc oxide (ZnO) nanomaterial when dispersed in fish medium.

  18. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  19. Comparison of total protein concentration in skeletal muscle as measured by the Bradford and Lowry assays.

    Science.gov (United States)

    Seevaratnam, Rajini; Patel, Barkha P; Hamadeh, Mazen J

    2009-06-01

    The Lowry and Bradford assays are the most commonly used methods of total protein quantification, yet vary in several aspects. To date, no comparisons have been made in skeletal muscle. We compared total protein concentrations of mouse red and white gastrocnemius, reagent stability, protein stability and range of linearity using both assays. The Lowry averaged protein concentrations 15% higher than the Bradford with a moderate correlation (r = 0.36, P = 0.01). However, Bland-Altman analysis revealed considerable bias (15.8 +/- 29.7%). Both Lowry reagents and its protein-reagent interactions were less stable over time than the Bradford. The linear range of concentration was smaller for the Lowry (0.05-0.50 mg/ml) than the Bradford (0-2.0 mg/ml). We conclude that the Bradford and Lowry measures of total protein concentration in skeletal muscle are not interchangeable. The Bradford and Lowry assays have various strengths and weaknesses in terms of substance interference and protein size. However, the Bradford provides greater reagent stability, protein-reagent stability and range of linearity, and requires less time to analyse compared to the Lowry assay.

  20. Measurement of the total proton-proton cross section with ATLAS at LHC

    CERN Document Server

    khalek, Samah Abdel

    It is now nearly fifty years since total proton-proton (pp) cross sections have been found to grow with energy after it was believed for long time that they would become asymptotically constant . The uncertainties of the cosmic ray data, at high energy, do not allow to determine the exact growth with energy of the total cross section .The Large Hadron Collider (LHC) at CERN in Geneva has already delivered collisions with an energy never reached in a particle accelerator. The energy in the center of mass was 7 TeV (2010 - 2011) or 8 TeV (2012) and will ultimately reached 14 TeV in the near future. Thus, this will provide a good environment for a new precise measurement of the total pp cross section at this energy.The ATLAS detector installed in one of the four LHC interaction points is used to collect the result of the pp collisions. Its sub-detector ALFA located 240 m from the interaction point, is used to track protons resulting from elastic collisions.Therefore, within special beam optics conditions, ALFA i...

  1. Resonance structure of 32S+n from measurements of neutron total and capture cross sections

    International Nuclear Information System (INIS)

    Halperin, J.; Johnson, C.H.; Winters, R.R.; Macklin, R.L.

    1980-01-01

    Neutron total and capture cross sections of 32 S have been measured up to 1100 keV neutron energy [E/sub exc/( 33 S) =9700 keV]. Spin and parity assignments have been made for 28 of the 64 resonances found in this region. Values of total radiation widths, reduced neutron widths, level spacings, and neutron strength functions have been evaluated for s/sub 1/2/, p/sub 1/2/, p/sub 3/2/, and d/sub 5/2/ levels. Single particle contributions using the valency model account for a significant portion of the total radiation width only for the p/sub 1/2/-wave resonances. A significant number of resonances can be identified with reported levels excited in 32 S(d,p) and 29 Si(α,n) reactions. A calculation of the Maxwellian average cross section appropriate to stellar interiors indicates an average capture cross section at 30 keV, sigma-bar approx. = 4.2(2) mb, a result that is relatively insensitive to the assumed stellar temperature. Direct (potential) capture and the s-wave resonance capture contributions to the thermal capture cross section do not fully account for the reported thermal cross section (530 +- 40 mb) and a bound state is invoked to account for the discrepancy

  2. Robust IR Remote Sensing Technique of the Total Column of Trace Gases Including Carbon Dioxide and Methane

    Science.gov (United States)

    Georgieva, E. M.; Heaps, W. S.

    2011-01-01

    Progress on the development of a differential radiometer based upon the Fabry-Perot interferometer (FPI) for methane (CH4) and carbon dioxide (C02) detection in the atmosphere is presented. Methane measurements are becoming increasingly important as a component of NASA's programs to understand the global carbon cycle and quantifY the threat of global warming. Methane is the third most important greenhouse gas in the Earth's radiation budget (after water vapor and carbon dioxide) and the second most important anthropogenic contributor to global warming. The importance of global warming and air quality to society caused the National Research Council to recommend that NASA develop the following missions [1]: ASCENDS (Active Sensing of C02 Emissions over Nights, Days, and Seasons), GEOCAPE (Geostationary Coastal and Air Pollution Events), and GACM (Global Atmosphere Composition Mission). Though methane measurements are not specifically called out in these missions, ongoing environmental changes have raised the importance of understanding the methane budget. In the decadal survey is stated that "to close the carbon budget, we would also address methane, but the required technology is not obvious at this time. If appropriate and cost-effective methane technology becomes available, we strongly recommend adding a methane capability". In its 2007 report the International Panel on Climate Change identified methane as a key uncertainty in our understanding saying that the causes of recent changes in the growth rate of atmospheric CH4 are not well understood. What we do know is that methane arises from a number of natural sources including wet lands and the oceans plus man made sources from agriculture, as well as coal and petroleum production and distribution. It has recently been pointed out that large amount of methane are frozen in the permafrost of Canada and Siberia. There is a fear that melting of this permafrost driven by global warming may release large amounts of

  3. Absolute luminosity and proton-proton total cross section measurement for the ATLAS experiment at LHC

    International Nuclear Information System (INIS)

    Heller, Matthieu

    2010-01-01

    The Large Hadron Collider (LHC) at CERN in Geneva will soon deliver collisions with an energy never reached in a particle accelerator. An energy in the center of mass of 10 and ultimately 14 TeV will allow to go beyond the borders of the physics known so far. ATLAS, the largest detector ever built, will hunt the Higgs boson and search for new physics beyond the Standard Model. Any physical process is described by a cross section that measures its probability to occur. The events resulting from a given process are registered by ATLAS. To determine their according cross section, one has to know the luminosity. For the ATLAS experiment, a relative measurement of the luminosity can be done using the response of several sub-detectors. However to calibrate these detectors, an absolute measurement has to be performed. The ALFA detector has been designed to measure the elastic scattering spectrum that will allow to determine the absolute luminosity and the proton-proton total cross section. This provides an accurate calibration tool at a percent level. These detectors, located 240 m away from the interaction point, are called roman pots, a mechanical system that allows to approach a scintillating fiber tracker a few millimeters to the beam center. The simulation of the measurement requires to use a charged particles transport program. This program has to be carefully chosen because the determination of the protons lost during their travel from the interaction point to the detector has a major impact on the acceptance computation. The systematical uncertainties affecting the luminosity and the total cross section measurements are also determined using the full simulation chain. The ALFA detector operates in a complex environment and consequently its design requires a great care. A large tests campaign has been performed on the front end electronics. The results and the corresponding data analysis have shown that all requirement where fulfilled. A test beam has been

  4. Relationship of bifenthrin sediment concentrations to grain size and total organic carbon in California waterbodies: implications for ecological risk.

    Science.gov (United States)

    Hall, Lenwood W; Anderson, Ronald D

    2014-12-01

    A summary analysis of data sets from six California waterbodies was conducted to determine the relationship of bifenthrin sediment concentrations to: % sand/gravel; % silt; % clay; % silt/clay and % total organic carbon (TOC). The relationship of TOC to % sand/gravel, % silt, % clay, and % silt/clay was also analyzed. Statistically significant and meaningful direct relationships were reported between bifenthrin and % TOC, % silt, % clay and % silt/clay while a significant and meaningful inverse relationship was reported between bifenthrin and % sand/gravel. A significant and meaningful inverse relationship was reported between % TOC and % sand/gravel, while a significant and meaningful direct relationship was reported between % TOC and % silt, % clay and % silt/clay. Significant bifenthrin sediment concentrations would not be expected in non-depositional (sand/gravel) areas which have been reported to be dominant in various streams in California's Central Valley and are also the preferred habitat for many benthic macroinvertebrate taxa.

  5. Investigation of the Makeup, Source, and Removal Strategies for Total Organic Carbon in the Oxygen Generation System Recirculation Loop

    Science.gov (United States)

    Bowman, Elizabeth M.; Carpenter, Joyce; Roy, Robert J.; Van Keuren, Steve; Wilson, Mark E.

    2015-01-01

    Since 2007, the Oxygen Generation System (OGS) on board the International Space Station (ISS) has been producing oxygen for crew respiration via water electrolysis. As water is consumed in the OGS recirculating water loop, make-up water is furnished by the ISS potable water bus. A rise in Total Organic Carbon (TOC) was observed beginning in February, 2011, which continues through the present date. Increasing TOC is of concern because the organic constituents responsible for the TOC were unknown and had not been identified; hence their impacts on the operation of the electrolytic cell stack components and on microorganism growth rates and types are unknown. Identification of the compounds responsible for the TOC increase, their sources, and estimates of their loadings in the OGA as well as possible mitigation strategies are presented.

  6. Accuracy of total oxidant measurement as obtained by the phenolphthalin method

    Energy Technology Data Exchange (ETDEWEB)

    Louw, C W; Halliday, E C

    1963-01-01

    The phenolphthalin method of Haagen-Smit and Brunelle (1958) was chosen for a preliminary survey of total oxidant level in Pretoria air, because of its sensitivity. Difficulty, however, was encountered in obtaining reliable standard curves. Some improvement was obtained when conducting all operations except photometer measurements at the temperature of melting ice. It was also found that when the sequence of adding the reagents was changed, so as to simulate conditions during actual sampling, a standard curve approximating a straight line and differing considerably from that of McCabe (1953) was obtained. It follows that values of total oxidant obtained by any experimentor will depend to a certain extent upon the method of standard curve preparation he uses, and when comparisons are made between measurements by experimentors in different towns or countries this factor should be taken into consideration. The accuracy (95% confidence) obtained by the phenolphthalin method, using the mean of three successive samples, was shown to be in the region of 30% for very low amounts of oxidant.

  7. Measurements and modeling of total solar irradiance in X-class solar flares

    International Nuclear Information System (INIS)

    Moore, Christopher Samuel; Chamberlin, Phillip Clyde; Hock, Rachel

    2014-01-01

    The Total Irradiance Monitor (TIM) from NASA's SOlar Radiation and Climate Experiment can detect changes in the total solar irradiance (TSI) to a precision of 2 ppm, allowing observations of variations due to the largest X-class solar flares for the first time. Presented here is a robust algorithm for determining the radiative output in the TIM TSI measurements, in both the impulsive and gradual phases, for the four solar flares presented in Woods et al., as well as an additional flare measured on 2006 December 6. The radiative outputs for both phases of these five flares are then compared to the vacuum ultraviolet (VUV) irradiance output from the Flare Irradiance Spectral Model (FISM) in order to derive an empirical relationship between the FISM VUV model and the TIM TSI data output to estimate the TSI radiative output for eight other X-class flares. This model provides the basis for the bolometric energy estimates for the solar flares analyzed in the Emslie et al. study.

  8. Carbon dioxide flux measurements from a coastal Douglas-fir forest floor

    International Nuclear Information System (INIS)

    Drewitt, G.B.

    2002-01-01

    This thesis examined the process that affects the exchange of carbon between the soil and the atmosphere with particular attention to the large amounts of carbon stored in soils in the form of decaying organic matter. This forest floor measuring study was conducted in 2000 at a micro-meteorological tower flux site in a coastal temperature Douglas-fir forest. The measuring study involved half hourly measurements of both carbon dioxide and below-ground carbon dioxide storage. Measurements were taken at 6 locations between April and December to include a large portion of the growing season. Eddy covariance (EC) measurements of carbon dioxide flux above the forest floor over a two month period in the summer and the autumn were compared with forest floor measurements. Below-ground carbon dioxide mixing ratios of soil air were measured at 6 depths between 0.02 to 1 m using gas diffusion probes and a syringe sampling method. Maximum carbon dioxide fluxes measured by the soil chambers varied by a factor of 3 and a high spatial variability in soil carbon dioxide flux was noted. Forest floor carbon dioxide fluxes measured by each of the chambers indicated different sensitivities to soil temperature. Hysteresis in the flux temperature relationship over the year was evident. Reliable below-canopy EC measurements of the forest floor carbon dioxide flux were difficult to obtain because of the every low wind speeds below the forest canopy. The amount of carbon dioxde present in the soil increased rapidly with depth near the surface but less rapidly deeper in the soil. It was suggested that approximately half of the carbon dioxide produced below-ground comes from between the soil surface and the first 0.15 m of depth. Carbon dioxide fluxes from the floor of a Douglas-fir forest were found to be large compared to other, less productive ecosystems

  9. Chemical attributes, total organic carbon stock and humified fractions of organic matter soil submitted to different systems of sugarcane management

    Directory of Open Access Journals (Sweden)

    Jean Sérgio Rosset

    2014-10-01

    Full Text Available Mechanized harvesting maintenance of trash from cane sugar and soil application of waste as vinasse and filter cake can improve the system of crop yield. Thus, this study aimed to evaluate the changes in the chemical, the stock of total organic carbon and humified organic matter fractions in an Oxisol cultivated with cane sugar with the following management systems: with sugarcane vinasse application (CCV, without application of burnt cane waste (CQS, with burnt cane vinasse application (CQV, with application of burnt cane filter cake (CQTF and burnt cane with joint application of vinasse and filter cake (CQVTF. For reference we used an area of natural vegetation (NV, Cerrado sensu stricto. Treatment CQVTF showed improvement in soil chemical properties, increased inventory levels of total organic carbon – TOC (values ranging from 21.28 to 40.02 Mg ha-1 and humified fractions of soil organic matter in relation to other treatments. The CQS area at a depth of 0-0.05 m, showed the greatest losses of soil TOC stocks (56.3% compared to NV. The adoption of management presented CCV and chemical attributes of the soil TOC stocks equivalent to those observed in areas with CQV CQTF and despite the short period of adoption (3 years. The TOC correlated with the sum of bases (r = 0.76 **, cation exchange capacity (r = 0.59 ** and base saturation (r = 0.63 **, while the humic acids (r = 0.40 ** fulvic acids (r = 0.49 ** and humin (r = 0.59 ** correlated with the cation exchange capacity of the soil. These results indicate that the preservation of trash in the management of cane sugar added to the application of vinasse and filter cake increases the TOC stocks promoting improvement in soil chemical properties.

  10. Objectively Measured Total and Occupational Sedentary Time in Three Work Settings

    Science.gov (United States)

    van Dommelen, Paula; Coffeng, Jennifer K.; van der Ploeg, Hidde P.; van der Beek, Allard J.; Boot, Cécile R. L.; Hendriksen, Ingrid J. M.

    2016-01-01

    Background Sedentary behaviour increases the risk for morbidity. Our primary aim is to determine the proportion and factors associated with objectively measured total and occupational sedentary time in three work settings. Secondary aim is to study the proportion of physical activity and prolonged sedentary bouts. Methods Data were obtained using ActiGraph accelerometers from employees of: 1) a financial service provider (n = 49 men, 31 women), 2) two research institutes (n = 30 men, 57 women), and 3) a construction company (n = 38 men). Total (over the whole day) and occupational sedentary time, physical activity and prolonged sedentary bouts (lasting ≥30 minutes) were calculated by work setting. Linear regression analyses were performed to examine general, health and work-related factors associated with sedentary time. Results The employees of the financial service provider and the research institutes spent 76–80% of their occupational time in sedentary behaviour, 18–20% in light intensity physical activity and 3–5% in moderate-to-vigorous intensity physical activity. Occupational time in prolonged sedentary bouts was 27–30%. Total time was less sedentary (64–70%), and had more light intensity physical activity (26–33%). The employees of the construction company spent 44% of their occupational time in sedentary behaviour, 49% in light, and 7% in moderate intensity physical activity, and spent 7% in sedentary bouts. Total time spent in sedentary behavior was 56%, 40% in light, and 4% in moderate intensity physical behaviour, and 12% in sedentary bouts. For women, low to intermediate education was the only factor that was negatively associated with occupational sedentary time. Conclusions Sedentary behaviour is high among white-collar employees, especially in highly educated women. A relatively small proportion of sedentary time was accrued in sedentary bouts. It is recommended that worksite health promotion efforts should focus on reducing sedentary

  11. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target.

    Science.gov (United States)

    Dubey, P K; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  12. Measurement of Deformations by MEMS Arrays, Verified at Sub-millimetre Level Using Robotic Total Stations

    Directory of Open Access Journals (Sweden)

    Tomas Beran

    2014-06-01

    Full Text Available Measurement of sub-millimetre-level deformations of structures in the presence of ambienttemperature changes can be challenging. This paper describes the measurement of astructure moving due to temperature changes, using two ShapeAccelArray (SAAinstruments, and verified by a geodetic monitoring system. SAA is a geotechnicalinstrument often used for monitoring of displacements in soil. SAA uses micro-electro-mechanical system (MEMS sensors to measure tilt in the gravity field. The geodeticmonitoring system, which uses ALERT software, senses the displacements of targetsrelative to control points, using a robotic total station (RTS. The test setup consists of acentral four-metre free-standing steel tube with other steel tubes welded to most of itslength. The central tube is anchored in a concrete foundation. This composite “pole” isequipped with two SAAs as well as three geodetic prisms mounted on the top, in the middle,and in the foundation. The geodetic system uses multiple control targets mounted inconcrete foundations of nearby buildings, and at the base of the pole. Long-termobservations using two SAAs indicate that the pole is subject to deformations due to cyclicalambient temperature variations causing the pole to move by a few millimetres each day. Ina multiple-day experiment, it was possible to track this movement using SAA as well as theRTS system. This paper presents data comparing the measurements of the two instrumentsand provides a good example of the detection of two-dimensional movements of seeminglyrigid objects due to temperature changes.

  13. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    Science.gov (United States)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-05-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique.

  14. Measurement of total ultrasonic power using thermal expansion and change in buoyancy of an absorbing target

    International Nuclear Information System (INIS)

    Dubey, P. K.; Kumar, Yudhisther; Gupta, Reeta; Jain, Anshul; Gohiya, Chandrashekhar

    2014-01-01

    The Radiation Force Balance (RFB) technique is well established and most widely used for the measurement of total ultrasonic power radiated by ultrasonic transducer. The technique is used as a primary standard for calibration of ultrasonic transducers with relatively fair uncertainty in the low power (below 1 W) regime. In this technique, uncertainty comparatively increases in the range of few watts wherein the effects such as thermal heating of the target, cavitations, and acoustic streaming dominate. In addition, error in the measurement of ultrasonic power is also caused due to movement of absorber at relatively high radiated force which occurs at high power level. In this article a new technique is proposed which does not measure the balance output during transducer energized state as done in RFB. It utilizes the change in buoyancy of the absorbing target due to local thermal heating. The linear thermal expansion of the target changes the apparent mass in water due to buoyancy change. This forms the basis for the measurement of ultrasonic power particularly in watts range. The proposed method comparatively reduces uncertainty caused by various ultrasonic effects that occur at high power such as overshoot due to momentum of target at higher radiated force. The functionality of the technique has been tested and compared with the existing internationally recommended RFB technique

  15. A neutron detector for measurement of total neutron production cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Sekharan, K K; Laumer, H; Kern, B D; Gabbard, F [Kentucky Univ., Lexington (USA). Dept. of Physics and Astronomy

    1976-03-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight /sup 10/BF/sub 3/ counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from /sup 7/Li(p, n)/sup 7/Be. By adjusting the radial positions of the BF/sub 3/ counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from /sup 51/V(p, n)/sup 51/Cr and /sup 57/Fe(p, n)/sup 57/Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given.

  16. A neutron detector for measurement of total neutron production cross sections

    International Nuclear Information System (INIS)

    Sekharan, K.K.; Laumer, H.; Kern, B.D.; Gabbard, F.

    1976-01-01

    A neutron detector has been constructed and calibrated for the accurate measurement of total neutron production cross sections. The detector consists of a polyethylene sphere of 60 cm diameter in which eight 10 BF 3 counters have been installed radially. The relative efficiency of this detector has been determined for average neutron energies from 30 keV to 1.5 MeV by counting neutrons from 7 Li(p, n) 7 Be. By adjusting the radial positions of the BF 3 counters in the polyethylene sphere the efficiency for neutron detection was made nearly constant for this energy range. Measurement of absolute efficiency for the same neutron energy range has been done by counting the neutrons from 51 V(p, n) 51 Cr and 57 Fe(p, n) 57 Co reactions and determining the absolute number of residual nuclei produced during the measurement of neutron yield. Details of absolute efficiency measurements and the use of the detector for determination of neutron production cross sections are given. (Auth.)

  17. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  18. Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ji Ho [KAERI, Daejeon (Korea, Republic of)

    2009-08-15

    The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

  19. Gap-Balancing versus Measured Resection Technique in Total Knee Arthroplasty: A Comparison Study.

    Science.gov (United States)

    Churchill, Jessica L; Khlopas, Anton; Sultan, Assem A; Harwin, Steven F; Mont, Michael A

    2018-01-01

    Proper femoral component alignment in the axial plane during total knee arthroplasty (TKA) depends on accurate bone cuts and soft tissue balancing. Two methods that are used to achieve this are "measured resection" and "gap balancing." However, a controversy exists as to which method is more accurate and leads to better outcomes. Therefore, the purpose of this study was to evaluate: (1) implant survivorship, (2) patient outcomes, (3) complications, and (4) radiographic analysis comparing patients who underwent TKA with either gap-balancing or measured resection techniques. A total of 214 consecutive patients (221 knees) underwent primary TKA by a single surgeon between 2011 and 2012. Component alignment was achieved by using measured resection in 116 knees and gap balancing was used in 105 knees. The patients had a mean age of 66 years (range, 44-86 years) and a mean body mass index of 32 kg/m 2 (range, 22-52 kg/m 2 ). Patient range-of-motion (ROM) and Knee Society (KS) function and pain scores, and radiographic assessment, were assessed preoperatively and postoperatively at ∼6 weeks, 3 months, 1 year, and then annually. The mean follow-up time was 3 years. A Kaplan-Meier's analysis was performed to calculate the survivorship. The aseptic survivorship was 98% in both the measured resection and gap-balancing groups. The mean ROM was not significantly different between the measured resection and gap-balancing groups (123 vs. 123 degrees, p  = 0.990). There were no significant differences between the two groups in terms of the KS function scores (86 vs. 85 points, p  = 0.829) or the KS pain scores (93 vs. 92 points, p  = 0.425). Otherwise, the radiographic evaluation at latest follow-up did not demonstrate any evidence of progressive radiolucencies or loosening, of any prosthesis. The results of this study found that at a mean follow-up of 3 years, both the measured resection and gap-balancing techniques achieved excellent survivorship and

  20. Protective effects of total glucosides of paeony and the underlying mechanisms in carbon tetrachloride-induced experimental liver injury

    Science.gov (United States)

    Qin, Ying; Tian, Ya-ping

    2011-01-01

    Introduction We explored the protective effects of total glucosides of paeony (TGP) and the underlying mechanisms in carbon tetrachloride (CCl4)-induced experimental liver injury in mice. Material and methods Chronic liver damage was induced by intraperitoneal injection of CCl4 (0.5 µl/g) three times per week for 8 weeks. Mice also received 25, 50 or 100 mg/kg TGP. Liver sections were stained with haematoxylin/eosin. Serum amino transferases, lipid peroxidation and tumour necrosis factor-α (TNF-α) levels were determined using commercial assays. Quantitative real-time polymerase chain reaction was used to determine the changes in hepatic TNF-α, COX-2, iNOS and HO-1 expression. Protein levels of nitric oxide synthase, cyclooxygenase-2, haem oxygenase-1 and cytochrome P450 2E1 were determined by western blotting. Results Histological results showed that TGP improved the CCl4-induced changes in liver structure and alleviated lobular necrosis. The increases in serum protein and hepatic mRNA expression of TNF-α induced by CCl4 treatment were suppressed by TGP. Total glucosides of paeony also attenuated the increase the expression in iNOS and CYP2E1 but augmented the increase in HO-1.The mRNA and protein expression levels of inducible HO-1 increased significantly after CCl4 treatment. Conclusions Total glucosides of paeony protects hepatocytes from oxidative damage induced by CCl4. Total glucosides of paeony may achieve these effects by enhancing HO-1 expression and inhibiting the expression of proinflammatory mediators. PMID:22291795

  1. Oil flow rate measurements using 198Au and total count technique

    International Nuclear Information System (INIS)

    Goncalves, Eduardo R.; Crispim, Verginia R.

    2013-01-01

    In industrial plants, oil and oil compounds are usually transported by closed pipelines with circular cross-section. The use of radiotracers in oil transport and processing industrial facilities allows calibrating flowmeters, measuring mean residence time in cracking columns, locate points of obstruction or leak in underground ducts, as well as investigating flow behavior or industrial processes such as in distillation towers. Inspection techniques using radiotracers are non-destructive, simple, economic and highly accurate. Among them, Total Count, which uses a small amount of radiotracer with known activity, is acknowledged as an absolute technique for flow rate measurement. A viscous fluid transport system, composed by four PVC pipelines with 13m length (12m horizontal and 1m vertical) and 1/2, 3/4, 1 and 2-inch gauges, respectively, interconnected by maneuvering valves was designed and assembled in order to conduct the research. This system was used to simulate different flow conditions of petroleum compounds and for experimental studies of flow profile in the horizontal and upward directions. As 198 Au presents a single photopeak (411,8 keV), it was the radioisotope chosen for oil labeling, in small amounts (6 ml) or around 200 kBq activity, and it was injected in the oil transport lines. A NaI scintillation detector 2'x 2', with well-defined geometry, was used to measure total activity, determine the calibration factor F and, positioned after a homogenization distance and interconnected to a standardized electronic set of nuclear instrumentation modules (NIM), to detect the radioactive cloud. (author)

  2. A gravimetric method for the measurement of total spontaneous activity in rats.

    Science.gov (United States)

    Biesiadecki, B J; Brand, P H; Koch, L G; Britton, S L

    1999-10-01

    Currently available methods for the measurement of spontaneous activity of laboratory animals require expensive, specialized equipment and may not be suitable for use in low light conditions with nocturnal species. We developed a gravimetric method that uses common laboratory equipment to quantify the total spontaneous activity of rats and is suitable for use in the dark. The rat in its home cage is placed on a top-loading electronic balance interfaced to a computer. Movements are recorded by the balance as changes in weight and transmitted to the computer at 10 Hz. Data are analyzed on-line to derive the absolute value of the difference in weight between consecutive samples, and the one-second average of the absolute values is calculated. The averages are written to file for off-line analysis and summed over the desired observation period to provide a measure of total spontaneous activity. The results of in vitro experiments demonstrated that: 1) recorded weight changes were not influenced by position of the weight on the bottom of the cage, 2) values recorded from a series of weight changes were not significantly different from the calculated values, 3) the constantly decreasing force exerted by a swinging pendulum placed on the balance was accurately recorded, 4) the measurement of activity was not influenced by the evaporation of a fluid such as urine, and 5) the method can detect differences in the activity of sleeping and waking rats over a 10-min period, as well as during 4-hr intervals recorded during active (night-time) and inactive (daytime) periods. These results demonstrate that this method provides an inexpensive, accurate, and noninvasive method to quantitate the spontaneous activity of small animals.

  3. Measuring GNSS ionospheric total electron content at Concordia, and application to L-band radiometers

    Directory of Open Access Journals (Sweden)

    Vincenzo Romano

    2013-06-01

    Full Text Available In the framework of the project BIS - Bipolar Ionospheric Scintillation and Total Electron Content Monitoring, the ISACCO-DMC0 and ISACCO-DMC1 permanent monitoring stations were installed in 2008. The principal scope of the stations is to measure the ionospheric total electron content (TEC and to monitor the ionospheric scintillations, using high-sampling-frequency global positioning system (GPS ionospheric scintillation and TEC monitor (GISTM receivers. The disturbances that the ionosphere can induce on the electromagnetic signals emitted by the Global Navigation Satellite System constellations are due to the presence of electron density anomalies in the ionosphere, which are particularly frequent at high latitudes, where the upper atmosphere is highly sensitive to perturbations coming from outer space. With the development of present and future low-frequency space-borne microwave missions (e.g., Soil Moisture and Ocean Salinity [SMOS], Aquarius, and Soil Moisture Active Passive missions, there is an increasing need to estimate the effects of the ionosphere on the propagation of electromagnetic waves that affects satellite measurements. As an example, how the TEC data collected at Concordia station are useful for the calibration of the European Space Agency SMOS data within the framework of an experiment promoted by the European Space Agency (known as DOMEX will be discussed. The present report shows the ability of the GISTM station to monitor ionospheric scintillation and TEC, which indicates that only the use of continuous GPS measurements can provide accurate information on TEC variability, which is necessary for continuous calibration of satellite data.

  4. Analyzing 20 years of Black Carbon measurements in Germany

    Science.gov (United States)

    Kutzner, R. D.; Quedenau, J.; Kuik, F.; von Schneidemesser, E.; Schmale, J.

    2016-12-01

    Black Carbon (BC) is an important short-lived climate-forcing pollutant contributing to global warming through absorption of sunlight. In addition, BC, as a component of particulate matter (PM) exerts adverse health effects. Anthropogenic emission sources of BC include residential heating, transport, and agricultural fires, and the dominant natural emission source is wildfires. Despite the adverse effects of BC, legislation that requires mandatory monitoring of BC concentrations does not currently exist in the European Union (EU). Instead, BC is only indirectly monitored as component of PM10 and PM2.5 (PM with a diameter smaller 10 µm and 2.5 µm, respectively). Before the introduction of mandatory PM10 and PM2.5 monitoring in the EU in 2005 and 2015, respectively, `black smoke' (BS), a surrogate for BC, was a required measurement in Germany from the early 1990s. The annual mean limit value was 14 µg/m3 from 1995 and 8 µg/m³ from 1998. In 2004, many measurements were stopped, with the repeal of the regulations. In most German federal states a limited number BC monitoring stations continued to operate. We present a synthesis of BC data from 213 stations across Germany covering the period between 1994 and 2014. Due to the lack of a standardized method and respective legislation, the data set is very heterogeneous relying on twelve different measurement methods including chemical, optical, and thermal-optical methods. Stations include, among others, urban background, traffic and rural. We highlight results from the year 2009, as it is the year with the largest measurement coverage based on the same measurement method, with 28 stations. Further, we calculated trends in BC concentrations for 13 stations with at least 10 years of data, for median concentrations, as well as 5th percentile (background) and 95th percentile (peak episodes). Preliminary results suggest that concentrations have generally declined, with a larger trend at traffic stations compared to urban

  5. Modeling Soil Organic Carbon Turnover in Four Temperate Forests Based on Radiocarbon Measurements of Heterotrophic Respiration and Soil Organic Carbon

    Science.gov (United States)

    Ahrens, B.; Borken, W.; Muhr, J.; Schrumpf, M.; Savage, K. E.; Wutzler, T.; Trumbore, S.; Reichstein, M.

    2011-12-01

    Soils of temperate forests store significant amounts of soil organic matter and are considered to be net sinks of atmospheric CO2. Soil organic carbon (SOC) dynamics have been studied using the Δ14C signature of bulk SOC or different SOC fractions as observational constraints in SOC models. Further, the Δ14C signature of CO2 evolved during the incubation of soil and roots has been widely used together with Δ14C of total soil respiration to partition soil respiration into heterotrophic respiration (Rh) and root respiration. However, these data have rarely been used together as observational constraints to determine SOC turnover times. Here, we present a multiple constraints approach, where we used SOC stock and its Δ14C signature, and heterotrophic respiration and its Δ14C signature to estimate SOC turnover times of a simple serial two-pool model via Bayesian optimization. We used data from four temperate forest ecosystems in Germany and the USA with different disturbance and management histories from selective logging to afforestation in the late 19th and early 20th century. The Δ14C signature of the atmosphere with its prominent bomb peak was used as a proxy for the Δ14C signature of aboveground and belowground litterfall. The Δ14C signature of litterfall was lagged behind the atmospheric signal to account for the period between photosynthetic fixation of carbon and its addition to SOC pools. We showed that the combined use of Δ14C measurements of Rh and SOC stocks helped to better constrain turnover times of the fast pool (primarily by Δ14C of Rh) and the slow pool (primarily by Δ14C of SOC). In particular, by introducing two additional parameters that describe the deviation from steady state of the fast and slow cycling pool for both SOC and SO14C, we were able to demonstrate that we cannot maintain the often used steady-state assumption of SOC models in general. Furthermore, a new transport version of our model, including SOC transport via

  6. Fetal subcutaneous tissue measurements in pregnancy as a predictor of neonatal total body composition.

    Science.gov (United States)

    O'Connor, Clare; Doolan, Anne; O'Higgins, Amy; Segurado, Ricardo; Sheridan-Pereiraet, Margaret; Turner, Michael J; Stuart, Bernard; Kennelly, Máireád M

    2014-10-01

    The purpose of this study was to examine the relationship between prenatal measures of subcutaneous tissue as surrogate markers of fetal nutritional status and correlate them with neonatal total body composition. This prospective longitudinal study of 62 singleton pregnancies obtained serial biometry and subcutaneous tissue measurements at 28, 33 and 38 weeks gestation. These measurements were then correlated with neonatal body composition, which was analysed using the PEAPOD™ Infant Body Composition System (Cosmed USA, Concord, CA, USA). At 38 weeks gestation, fetal abdominal subcutaneous tissue (FAST) in millimetres was significantly associated with infant fat mass at delivery (+64 g per mm of FAST, p < 0.001). Thigh fat (TF) at 28 weeks gestation was associated with infant fat mass at delivery (+79 g/mm TF, p = 0.023). TF at 38 weeks gestation was associated with infant fat mass (+63/mm TF, p = 0.004). TF and FAST at 38 weeks were also predictive of both birth weight and increased abdominal circumference (AC) (p = 0.001) with FAST measurement predicting an additional 5.7 mm in AC per millimetre of FAST (p = 0.002) and TF predicting an additional 6.9 mm per mm of TF (p = 0.002). We believe that this study further validates the use of prenatal measures of subcutaneous tissue and may help to highlight fetuses at risk of newborn adiposity and metabolic syndrome. © 2014 John Wiley & Sons, Ltd.

  7. Measurements of Nitrogen Dioxide Total Column Amounts using a Brewer Double Spectrophotometer in Direct Sun Mode

    Science.gov (United States)

    Cede, Alexander; Herman, Jay; Richter, Andreas; Krotkov, Nickolay; Burrows, John

    2006-01-01

    NO2 column amounts were measured for the past 2 years at Goddard Space Flight Center, Greenbelt, Maryland, using a Brewer spectrometer in direct Sun mode. A new bootstrap method to calibrate the instrument is introduced and described. This technique selects the cleanest days from the database to obtain the solar reference spectrum. The main advantage for direct Sun measurements is that the conversion uncertainty from slant column to vertical column is negligible compared to the standard scattered light observations where it is typically on the order of 100% (2sigma) at polluted sites. The total 2sigma errors of the direct Sun retrieved column amounts decrease with solar zenith angle and are estimated at 0.2 to 0.6 Dobson units (DU, 1 DU approx. equal to 2.7 10(exp 16) molecules cm(exp -2)), which is more accurate than scattered light measurements for high NO2 amounts. Measured NO2 column amounts, ranging from 0 to 3 DU with a mean of 0.7 DU, show a pronounced daily course and a strong variability from day to day. The NO2 concentration typically increases from sunrise to noon. In the afternoon it decreases in summer and stays constant in winter. As expected from the anthropogenic nature of its source, NO2 amounts on weekends are significantly reduced. The measurements were compared to satellite retrievals from Scanning Image Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY). Satellite data give the same average NO2 column and show a seasonal cycle that is similar to the ground data in the afternoon. We show that NO2 must be considered when retrieving aerosol absorption properties, especially for situations with low aerosol optical depth.

  8. Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600.

    Science.gov (United States)

    Miler, Marijana; Nikolac Gabaj, Nora; Dukic, Lora; Simundic, Ana-Maria

    2017-12-27

    The aim of the study was to estimate improvement of work efficiency in the laboratory after implementation of total laboratory automation (TLA) by Abbott Accelerator a3600 in the laboratory with measuring different key performance indicators (KPIs) before and after TLA implementation. The objective was also to recommend steps for defining KPIs in other laboratories. For evaluation of improvement 10 organizational and/or technical KPIs were defined for all phases of laboratory work and measured before (November 2013) and after (from 2015 to 2017) TLA implementation. Out of 10 defined KPIs, 9 were successfully measured and significantly improved. Waiting time for registration of samples in the LIS was significantly reduced from 16 (9-28) to 9 (6-16) minutes after TLA (P performed at core biochemistry analyzers which significantly reduced walking distance for sample management (for more than 800 m per worker) and number of tube touches (for almost 50%). Analyzers downtime and engagement time for analyzers maintenance was reduced for 50 h and 28 h per month, respectively. TLA eliminated manual dilution of samples with extreme results with sigma values increment from 3.4 to >6 after TLA. Although median turnaround time TAT for potassium and troponin was higher (for approximately 20 min), number of outliers with TAT >60 min expressed as sigma values were satisfying (>3). Implementation of the TLA improved the most of the processes in our laboratory with 9 out of 10 properly defined and measured KPIs. With proper planning and defining of KPIs, every laboratory could measure changes in daily workflow.

  9. Measuring arrangement for simultaneous and continuous determination of the total and radioactive amounts of reactive matters in flowing inert gases. Pt. 1

    International Nuclear Information System (INIS)

    Figge, K.; Martinen, H.; Schulz, W.

    1976-01-01

    In order to investigate the metabolism behaviour of radiocarbon-labelled substances, a special apparatus has been designed which enables a fully automatic as well as continuous and simultaneous determination of the total and the 14 C-labelled carbon dioxide (CO 2 ) in the respiratory air of small animals. The CO 2 which is exhaled by the experimental animals is absorbed quantitatively in a novel absorber-scintillator cocktail. The quantity of combined total CO 2 is then determined by measuring the specific conductivity whereas the amount of radioactive CO 2 is assessed via scintillation measurement. The measuring accuracy achieved is around 10 N cm 3 or about 5 nCi, whereas the CO 2 recovery is above 98%. In addition to the recording in a linear recorder, the data are transferred to punching tapes and can be evaluated in an EDP unit. (orig.) [de

  10. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  11. Validation of six years of SCIAMACHY carbon monoxide observations using MOZAIC CO profile measurements

    Directory of Open Access Journals (Sweden)

    A. T. J. de Laat

    2012-09-01

    Full Text Available This paper presents a validation study of SCanning Imaging Absorption SpectroMeter for Atmospheric CartograpHY (SCIAMACHY carbon monoxide (CO total column measurements from the Iterative Maximum Likelihood Method (IMLM algorithm using vertically integrated profile aircraft measurements obtained within the MOZAIC project for the six year time period of 2003–2008.

    Overall we find a good agreement between SCIAMACHY and airborne measurements for both mean values – also on a year-to-year basis – as well as seasonal variations. Several locations show large biases that are attributed to local effects like orography and proximity of large emission sources. Differences were detected for individual years: 2003, 2004 and 2006 have larger biases than 2005, 2007 and 2008, which appear to be related to SCIAMACHY instrumental issues but require more research. Results from this study are consistent with, and complementary to, findings from a previous validation study using ground-based measurements (de Laat et al., 2010b. According to this study, the SCIAMACHY data, if individual measurements are of sufficient quality – good signal-to-noise, can be used to determine the spatial distribution and seasonal cycles of CO total columns over clean areas. Biases found over areas with strong emissions (Africa, China could be explained by low sensitivity of the instrument in the boundary layer and users are recommended to avoid using the SCIAMACHY data while trying to quantify CO burden and/or retrieve CO emissions in such areas.

  12. Carbon Balance at Landscape Level inferred fromTower CO2 Concentration Measurements

    Science.gov (United States)

    Chen, J. M.; Chen, B.; Higuchi, K.; Chan, D.; Shashkov, A.; Lin, H.; Liu, J.

    2003-04-01

    Terrestrial carbon sinks are considerable in the global carbon budget, but the accumulation of carbon in terrestrial ecosystems is very small (~0.2% per year) relative to the total carbon stocks in forests. Currently, eddy-covariance instruments mounted on towers are the only reliable means to measure carbon balance of a land surface, albeit limited to small areas and not free of caveats. In our quest of understanding the collective performance of ecosystems under the changing climate, it is highly desirable to have the ability to acquire carbon cycle information for large areas (landscape) consisting of patches of different ecosystems. For this purpose we explored methodologies of inferring carbon cycle information from tower CO2 concentration measurements affected by large areas (100-10000 km2). An ecosystem model named Boreal Ecosystem Productivity Simulator (BEPS) is coupled with a carbon-specific Vertical Diffusion Scheme (VDS) in order to decipher temporal variations in CO2 for landscape-level photosynthesis and respiration information. The coupled BEPS-VDS is applied to a unique 9-year (1990-2000 with 1997-8 missing data) 5-minute CO2 record measured on a 40-m tower over boreal forests near Fraserdale, Ontario, Canada. Over the period, the mean diurnal amplitude of the measured CO2 at 40 m increased by 5.58 ppmv, or 28% in the growing season. The increase in nighttime ecosystem respiration, causing the increase in the daily maximum CO2 concentration, was responsible for 65% of the increase in the diurnal amplitude, i.e., 3.61 ppmv, corresponding to an increase in the mean daily air temperature by about 2.77 degC and precipitation by 5% over the same period. The rest (35%) is explained by the increase in ecosystem daytime photosynthesis, causing the decrease in the daily minimum CO2 concentration. As the nighttime stable boundary layer (SBL) (270-560 m) was much shallower than the daytime convective boundary layer (CBL) (1000-1600 m), the increase in

  13. A gaseous measurement system for carbon-14 dioxide and carbon-14 methane: An analytical methodology to be applied in the evaluation of the carbon-14 dioxide and carbon-14 methane produced via microbial activity in volcanic tuff

    International Nuclear Information System (INIS)

    Dolan, M.M.

    1987-01-01

    The objectives of this study were to develop a gaseous measurement system for the carbon-14 dioxide and carbon-14 methane produced via microbial activity or geochemical action on leachate in tuff; to determine the trapping efficiency of the system for carbon-14 dioxide; to determine the trapping efficiency of the system for carbon-14 methane; to apply the experimentally determined factors regarding the system's trapping efficiency for carbon-14 dioxide and carbon-14 methane to a trapping algorithm to determine the activity of the carbon-14 dioxide and carbon-14 methane in a mixed sample; to determine the minimum detectable activity of the measurement process in picocuries per liter; and to determine the lower limit or detection of the measurement process in counts per minute

  14. [Study of relationship between consumption of potassium permanganate and total organic carbon on plastic kitchen utensils, food packages and toys].

    Science.gov (United States)

    Ohno, Hiroyuki; Suzuki, Masako; Mutsuga, Motoh; Kawamura, Yoko

    2009-10-01

    Consumption of potassium permanganate and total organic carbon (TOC) were investigated as indices of total organic matter migrated into water from plastic kitchen utensils, food packages and toys for children. The samples were soaked in water at 60 or 95 degrees C for 30 min for kitchen utensils and food packages, and at 40 degrees C for 30 min for toys and the eluates were examined, using the two indices. The quantitation limits were both 0.5 microg/mL. Among 97 kitchen utensils and food packages tested, consumption of potassium permanganate and TOC were 0.5-10.9 microg/mL and ND-18.9 microg/mL for polyvinyl chloride (PVC) tea-pot spouts and nylon kitchen utensils, respectively. Among 32 toys tested, the levels were 0.8-45.5 microg/mL and 0.5-8.9 microg/mL from PVC toys and block toys made by ethylene vinyl acetate resin. The levels for other samples were very low. There were large discrepancies between consumption of potassium permanganate and TOC for some PVC products and nylon kitchen utensils. The cause may be a marked difference of the oxidation decomposition rate by potassium permanganate, depending on the kind of organic matter that migrated from the plastics.

  15. Using 137Cs to quantify the redistribution of soil organic carbon and total N affected by intensive soil erosion in the headwaters of the Yangtze River, China

    International Nuclear Information System (INIS)

    Wei Guoxiao; Wang Yibo; Wang Yanlin

    2008-01-01

    Characteristics of soil organic carbon (SOC) and total nitrogen (total N) are important for determining the overall quality of soils. Studies on spatial and temporal variation in SOC and total N are of great importance because of global environmental concerns. Soil erosion is one of the major processes affecting the redistribution of SOC and total N in the test fields. To characterize the distribution and dynamics of SOC and N in the intensively eroded soil of the headwaters of the Yangtze River, China, we measured profiles of soil organic C, total N stocks, and 137 Cs in a control plot and a treatment plot. The amounts of SOC, 137 Cs of sampling soil profiles increased in the following order, lower>middle>upper portions on the control plot, and the amounts of total N of sampling soil profile increase in the following order: upper>middle>lower on the control plot. Intensive soil erosion resulted in a significant decrease of SOC amounts by 34.9%, 28.3% and 52.6% for 0-30 cm soil layer at upper, middle and lower portions and 137 Cs inventory decreased by 68%, 11% and 85% at upper, middle and lower portions, respectively. On the treatment plot total N decreased by 50.2% and 14.6% at the upper and middle portions and increased by 48.9% at the lower portion. Coefficients of variation (CVs) of SOC decreased by 31%, 37% and 30% in the upper, middle and lower slope portions, respectively. Similar to the variational trend of SOC, CVs of 137 Cs decreased by 19.2%, 0.5% and 36.5%; and total N decreased by 45.7%, 65.1% and 19% in the upper, middle and lower slope portions, respectively. The results showed that 137 Cs, SOC and total N moved on the sloping land almost in the same physical mechanism during the soil erosion procedure, indicating that fallout of 137 Cs could be used directly for quantifying dynamic SOC and total N redistribution as the soil was affected by intensive soil erosion

  16. Using (137)Cs to quantify the redistribution of soil organic carbon and total N affected by intensive soil erosion in the headwaters of the Yangtze River, China.

    Science.gov (United States)

    Guoxiao, Wei; Yibo, Wang; Yan Lin, Wang

    2008-12-01

    Characteristics of soil organic carbon (SOC) and total nitrogen (total N) are important for determining the overall quality of soils. Studies on spatial and temporal variation in SOC and total N are of great importance because of global environmental concerns. Soil erosion is one of the major processes affecting the redistribution of SOC and total N in the test fields. To characterize the distribution and dynamics of SOC and N in the intensively eroded soil of the headwaters of the Yangtze River, China, we measured profiles of soil organic C, total N stocks, and (137)Cs in a control plot and a treatment plot. The amounts of SOC, (137)Cs of sampling soil profiles increased in the following order, lower>middle>upper portions on the control plot, and the amounts of total N of sampling soil profile increase in the following order: upper>middle>lower on the control plot. Intensive soil erosion resulted in a significant decrease of SOC amounts by 34.9%, 28.3% and 52.6% for 0-30cm soil layer at upper, middle and lower portions and (137)Cs inventory decreased by 68%, 11% and 85% at upper, middle and lower portions, respectively. On the treatment plot total N decreased by 50.2% and 14.6% at the upper and middle portions and increased by 48.9% at the lower portion. Coefficients of variation (CVs) of SOC decreased by 31%, 37% and 30% in the upper, middle and lower slope portions, respectively. Similar to the variational trend of SOC, CVs of (137)Cs decreased by 19.2%, 0.5% and 36.5%; and total N decreased by 45.7%, 65.1% and 19% in the upper, middle and lower slope portions, respectively. The results showed that (137)Cs, SOC and total N moved on the sloping land almost in the same physical mechanism during the soil erosion procedure, indicating that fallout of (137)Cs could be used directly for quantifying dynamic SOC and total N redistribution as the soil was affected by intensive soil erosion.

  17. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  18. Measurement of fluorine total concentration in dental enamel using fast neutron activation

    International Nuclear Information System (INIS)

    Mouadili, A.; Vernais, J.; Isabelle, D.B.

    1988-01-01

    Fluorine which is present in dental enamel, at the level of a few tens to a few hundred ppm, plays an important role in the behaviour of this tissue. Therefore quantitative determination is of interest for particular studies of the dental system. We present a nuclear nondestructive method to determine the total fluorine content in dental enamel by cyclotron-produced fast-neutron activation. The 19 F(n,2n) reaction leads to 18 F which is a β + emitter with a 109.8 min half-life. The irradiated sample activity is measured by detecting in coincidence the annihilation photons. A fluorine standard is used for calibration. The detection limit is of the order of 1 ppm, while the reproducibility is better than 95% [pt

  19. Measurements of the effective total and resonance absorption cross sections for zircaloy-2 and zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Kocic, A; Markovic, V [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1967-04-15

    Zirconium and zircaloy-2 alloy, as constructive materials, have found wide application in reactor technology, especially in heavy water systems for two reasons: a) low neutron absorption cross section, b) good mechanical properties. The thickness of the zirconium and zircaloy-2 for different applications varies from several tenths of a millimeter to about ten millimeters. Therefore, to calculate reactor systems it is desirable to know the effective neutron absorption cross section for the range of thicknesses mention above. The thermal neutron cross sections for these materials are low and no appreciable variation of the effective neutron cross section occurs even for the largest thicknesses. However, this is not true for effective resonance absorption. On the other hand, due to the lack of detailed knowledge of the zirconium resonances, calculations of the effective resonance integrals cannot be performed. Therefore it is necessary to measure the effective total and resonance absorption cross section for zirconium (author)

  20. Measuring the impact of total quality management on financial performance of croatian companies

    Directory of Open Access Journals (Sweden)

    Dubravka Pekanov Starčević

    2012-12-01

    Full Text Available Changes in the business environment have resulted in increasing the importance of the quality of products and services of a company. Insisting on quality has become a strategic goal of a company and a determiner of competitiveness both in the home and international market. The traditional approach to quality included determination of product quality after production was completed. High costs of testing to determine the quality of products and services concludes that quality assurance must be approached differently. Product controls and tests used until that moment had to be replaced with a more modern, more efficient and more effective approach known as total quality management (TQM. TQM supporters suggest that TQM implementation results in improved product quality, reduced product return, reduced costs of serving unsatisfied customers and other benefits that ultimately lead to improved financial performance of the company. This paper examines the impact of TQM imple- mentation on the financial performance of Croatian companies whose securities are traded within the regulated market. General characteristics of companies were compared in terms of (nonsystematic application of total quality management. Furthermore, the financial performance of the companies that have successfully implemented the method was measured.

  1. Measurement of total antioxidant capacity in gingival crevicular fluid and serum in dogs with periodontal disease.

    Science.gov (United States)

    Pavlica, Zlatko; Petelin, Milan; Nemec, Alenka; Erzen, Damjan; Skaleric, Uros

    2004-11-01

    To determine whether gingival crevicular fluid (GCF) and serum total antioxidant capacities (TACs) correlate with the degree of severity of periodontal disease in dogs. 41 Toy and Miniature Poodles. After assessment of the degree of severity of naturally occurring periodontitis, GCF samples from both maxillary fourth premolars and a blood sample were collected from each dog. The condition of the periodontium of the entire dentition and at each site of GCF collection was recorded. Clinical parameters assessed included plaque index, gingival index, and probing depth. Radiographic analysis of alveolar bone level was also performed. Total antioxidant capacity was measured in GCF and serum samples by use of a commercial kit. Dogs with gingivitis and minimal periodontitis had significantly higher TAC in GCF than dogs with advanced periodontitis. Bivariate regression analysis revealed significant negative correlations between TAC in GCF and clinical parameters and age. The TAC in serum was significantly negatively correlated with the degree of gingival inflammation but was not significantly correlated with age. TAC in GCF is related to the degree of severity of periodontal disease in dogs. This is likely the result of release of reactive oxygen species by activated phagocytes and fibroblasts in the inflamed periodontal tissues. The results of our study suggest that the local delivery of antioxidants may be a useful adjunctive treatment for periodontitis in dogs.

  2. Ultrasound-assisted extraction for total sulphur measurement in mine tailings

    International Nuclear Information System (INIS)

    Khan, Adnan Hossain; Shang, Julie Q.; Alam, Raquibul

    2012-01-01

    Highlights: ► We develop a total sulphur measuring procedure of mine tailings. ► Ultrasound is used in the sample pre-treatment process. ► Full factorial design is applied to identify the best level of effecting factors. - Abstract: A sample preparation method for percentage recovery of total sulphur (%S) in reactive mine tailings based on ultrasound-assisted digestion (USAD) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) was developed. The influence of various methodological factors was screened by employing a two-level and three-factor (2 3 ) full factorial design and using KZK-1, a sericite schist certified reference material (CRM), to find the optimal combination of studied factors and %S. Factors such as the sonication time, temperature and acid combination were studied, with the best result identified as 20 min of sonication, 80 °C temperature and 1 ml of HNO 3 :1 ml of HCl, which can achieve 100% recovery for the selected CRM. Subsequently a fraction of the 2 3 full factorial design was applied to mine tailings. The percentage relative standard deviation (%RSD) for the ultrasound method is less than 3.0% for CRM and less than 6% for the mine tailings. The investigated method was verified by X-ray diffraction analysis. The USAD method compared favorably with existing methods such as hot plate assisted digestion method, X-ray fluorescence and LECO™-CNS method.

  3. Integration of In-Flight and Post-Flight Water Monitoring Resources in Addressing the U.S. Water Processor Assembly Total Organic Carbon (TOC) Anomaly

    Science.gov (United States)

    Straub, John E., II; McCly, J. Torin

    2011-01-01

    Beginning in June of 2010, the total organic carbon (TOC) concentration in the U.S. Water Processor Assembly (WPA) product water started to increase. A surprisingly consistent upward TOC trend was observed through weekly ISS total organic carbon analyzer (TOCA) monitoring. As TOC is a general organic compound indicator, return of water archive samples was needed to make better-informed crew health decisions on the specific compounds of concern and to aid in WPA troubleshooting. TOCA-measured TOC was more than halfway to the health-based screening limit of 3,000 g/L before archive samples were returned. Archive samples were returned on 22 Soyuz in September 2010 and on ULF5 in November of 2010. The samples were subjected to extensive analysis. Although TOC was confirmed to be elevated, somewhat surprisingly, none of the typical target compounds were detected at high levels. After some solid detective work, it was confirmed that the TOC was associated with a compound known as dimethylsilanediol (DMSD). DMSD is believed to be a breakdown product of siloxanes which are thought to be ubiquitous in the ISS atmosphere. A toxicological limit was set for DMSD and a forward plan was developed for conducting operations in the context of understanding the composition of the TOC measured in flight. This required careful consideration of existing ISS flight rules, coordination with ISS stakeholders, and development of a novel approach for the blending of inflight TOCA data with archive results to protect crew health. Among other challenges, team members had to determine how to utilize TOCA readings when making decisions about crew consumption of WPA water. This involved balancing very real concerns associated with the assumption that TOC would continue to be comprised of only DMSD. Demonstrated teamwork, multidisciplinary awareness, and innovative problem-solving were required to respond effectively to this anomaly.

  4. Dissolved inorganic carbon, total alkalinity, pH, nutrients, and other variables collected from surface discrete observations using Niskin bottle and other instruments from R/V F. G. Walton Smith in the west coast of Florida within Gulf of Mexico from 2015-09-23 to 2015-09-24 (NCEI Accession 0157025)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains the surface discrete measurements of dissolved inorganic carbon, total alkalinity, pH and nutrients in the west coast of Florida near...

  5. Dissolved inorganic carbon, total alkalinity, pH, and other variables collected from surface and discrete observations using flow-through pump and other instruments from M/V Equinox in the North Atlantic ocean (east coast of Miami, FL, Bahamas, and Turks and Caicos Islands) from 2015-03-07 to 2015-03-09 (NCEI Accession 0154382)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains surface discrete measurements of dissolved inorganic carbon, total alkalinity, and pH from the east coast of Florida to Puerto Rico....

  6. Dissolved inorganic carbon, total alkalinity, pH, nutrients, and other variables collected from profile and discrete observations using Niskin bottle and other instruments from NOAA Ship Gordon Gunter on the northeastern U.S. continental shelf, Gulf of Maine, coastal waters of Canada, Greenland and Iceland from 2015-10-13 to 2015-10-24 (NCEI Accession 0157023)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains profile discrete measurements of dissolved inorganic carbon, total alkalinity, pH, dissolved oxygen, and nutrients in the North...

  7. Dissolved inorganic carbon, total alkalinity, pH, and other variables collected from surface discrete observations using flow through pump and other instruments from Explorer of the Seas (ID: 33KF) in the Caribbean Sea and North Atlantic ocean during the Ocean Acidification Cruise EX1507 from 2015-02-14 to 2015-02-15 (NCEI Accession 0154385)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains surface discrete measurements of dissolved inorganic carbon, total alkalinity, pH in the Caribbean Sea. Increasing amounts of...

  8. Dissolved inorganic carbon, total alkalinity, pH, and other variables collected from surface and discrete observations using Niskin bottle, flow-through pump and other instruments from F.G. Walton Smith in the Gulf of Mexico (east coast of Florida near the Keys) from 2014-12-03 to 2014-12-04 (NCEI Accession 0154383)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains surface discrete measurement of dissolved inorganic carbon, total alkalinity, pH, dissolved oxygen and nutrients from a transect off...

  9. Dissolved inorganic carbon, total alkalinity, nutrients, and other variables collected from profile and discrete observations using Niskin bottle and other instruments from NOAA Ship Henry B. Bigelow in Gulf of Maine, Georges Bank, and Mid-Atlantic Bight from 2015-05-20 to 2015-06-02 (NCEI Accession 0157024)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains profile discrete measurements of dissolved inorganic carbon, total alkalinity, nutrients, and chlorophyll a in Mid-Atlantic Bight and...

  10. Dissolved inorganic carbon, total alkalinity, pH, dissolved oxygen, and nutrients collected from profile, discrete sampling, and time series observations using CTD, Niskin bottle, and other instruments from R/V Gulf Challenger near a buoy off the coast of New Hampshire, U.S. in the Gulf of Maine from 2011-01-11 to 2015-11-18 (NCEI Accession 0142327)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains discrete measurements of dissolved inorganic carbon, total alkalinity, pH, dissolved oxygen, and nutrients collected at the buoy off...

  11. Dissolved inorganic carbon, total alkalinity, pH, nutrients, and other variables collected from surface discrete observations using flow-through pump and other instruments from NOAA Ship Henry B. Bigelow on the Northeast U.S. Shelf (Gulf of Maine and Mid-Atlantic Bight) from 2013-03-17 to 2013-05-09 (NCEI Accession 0154386)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This archival package contains surface discrete measurements of dissolved inorganic carbon, total alkalinity, pH and nutrients in the Mid-Atlantic Bight and Gulf of...

  12. Measures for carbon dioxide problem and utilization of energy

    International Nuclear Information System (INIS)

    Kojima, Toshinori

    1992-01-01

    As global environment problems, there are water, expansion of deserts, weather, tropical forests, wild animals, ocean pollution, nuclear waste contamination, acid rain, ozone layer and so on, and population, foods, energy, and resources are the problems surrounding them. It is clear that these origins are attributed to the development and consumption largely dependent on the intention of developed countries and the population problem of developing countries. In this report, the discharge of carbon dioxide that causes greenhouse effect and its relation with energy are discussed. The increase of carbon dioxide concentration, its release from fossil fuel, the destruction of forests, the balance of carbon on the earth, the development of new energy such as solar energy, the transport of new energy, secondary energy system and the role of carbon dioxide, the transfer to low carbon fuel and the carbon reduction treatment of fuel, the utilization of unused energy and energy price, the efficiency of energy utilization, the heightening of efficiency of energy conversion, energy conservation and the breakaway from energy wasteful use culture, and the recovery, preservation and use of discharged carbon dioxide are described. (K.I.)

  13. Measured Black Carbon Deposition on the Sierra Nevada Snow Pack and Implication for Snow Pack Retreat

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, O.L.; Corrigan, C.E.; Kirchstetter, T.W.; Cliff, S.S.; Ramanathan, V.

    2010-01-12

    Modeling studies show that the darkening of snow and ice by black carbon deposition is a major factor for the rapid disappearance of arctic sea ice, mountain glaciers and snow packs. This study provides one of the first direct measurements for the efficient removal of black carbon from the atmosphere by snow and its subsequent deposition to the snow packs of California. The early melting of the snow packs in the Sierras is one of the contributing factors to the severe water problems in California. BC concentrations in falling snow were measured at two mountain locations and in rain at a coastal site. All three stations reveal large BC concentrations in precipitation, ranging from 1.7 ng/g to 12.9 ng/g. The BC concentrations in the air after the snow fall were negligible suggesting an extremely efficient removal of BC by snow. The data suggest that below cloud scavenging, rather than ice nuclei, was the dominant source of BC in the snow. A five-year comparison of BC, dust, and total fine aerosol mass concentrations at multiple sites reveals that the measurements made at the sampling sites were representative of large scale deposition in the Sierra Nevada. The relative concentration of iron and calcium in the mountain aerosol indicates that one-quarter to one-third of the BC may have been transported from Asia.

  14. The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

    Directory of Open Access Journals (Sweden)

    Ascaso Carlos

    2010-04-01

    Full Text Available Abstract Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

  15. Thermogravimetric measurement of hydrogen storage in carbon-based materials: promise and pitfalls

    International Nuclear Information System (INIS)

    Pinkerton, F.E.; Wicke, B.G.; Olk, C.H.; Tibbetts, G.G.; Meisner, G.P.; Meyer, M.S.; Herbst, J.F.

    2000-01-01

    We have used a thermogravimetric analyzer (TGA) to measure the hydrogen absorption capacity of a variety of carbon-based storage materials, including Li- and K-intercalated graphite and Li-doped multi-wall nanotubes. The TGA uses weight gain/loss as a function of time and temperature to monitor hydrogen absorption/desorption in flowing hydrogen gas. Creating and maintaining a contaminant-free atmosphere is critical to the accurate TGA measurement of hydrogen absorption in carbon-based materials; even low concentrations of impurity gases such as O 2 or H 2 O are sufficient to masquerade as hydrogen absorption. We will discuss examples of this effect relevant to recent reports of hydrogen storage appearing in the literature. The precautions required are non-trivial. In our TGA, for instance, about 16% of the original atmosphere remains after a two-hour purge; at least 15 hours is required to fully purge the apparatus. Furthermore, we cover the TGA with a protective atmosphere enclosure during sample loading to minimize the introduction of impurity gases. With these precautions it is possible to unambiguously measure hydrogen storage. For example, we have determined the hydrogen absorption capacity of our K-intercalated graphite samples to be 1.3 wt% total hydrogen absorption above 50 o C, of which 0.2 wt% can be reproducibly recovered with temperature cycling. With due care, TGA measurements provide complementary information to that obtained from standard pressure techniques for measuring hydrogen sorption, which rely on measuring the loss of gas pressure in a known volume. Taken together, TGA and pressure measurements provide a powerful combination for determining verifiable hydrogen storage capacity. (author)

  16. Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio

    International Nuclear Information System (INIS)

    Keck, B.D.; Ognibene, T.; Vogel, J.S.

    2010-01-01

    Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of 14 C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14 C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the 14 C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with 14 C corresponds to 30 fg equivalents. AMS

  17. Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio.

    Energy Technology Data Exchange (ETDEWEB)

    Keck, B D; Ognibene, T; Vogel, J S

    2010-02-05

    Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of {sup 14}C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of {sup 14}C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the {sup 14}C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with {sup 14}C corresponds to 30 fg

  18. A gas extraction system for the measurement of carbon dioxide and carbon isotopes in polar ice cores

    International Nuclear Information System (INIS)

    Steig, E.

    1992-06-01

    Knowledge of the distribution of Carbon 13 in the glacial ocean, atmosphere, and biosphere is important to understanding the causes of glacial/interglacial changes in atmospheric CO 2 levels. Although deep-ocean Carbon 13 values are well-constrained by ocean sediment studies, model-based estimates of changes in the carbon budget for the biosphere and atmosphere vary considerably. Measurement of atmospheric Carbon 13 in CO 2 in ice cores will provide additional constraints on this budget and will also improve estimates of changes in the ocean surface layer Carbon 13. Direct measurement of ancient atmospheric Carbon 13 can be accomplished through polar ice core studies. A gas-extraction line for ice cores has been designed and constructed with particular attention to the specific difficulties of measuring Carbon 13 in CO 2 . The ice is shaved, rather than crushed, to minimize fractionation effects resulting from gas travel through long air-paths in the ice. To minimize the risk of isotopic contamination and fractionation within the vacuum line, CO 2 is separated immediately from the air; the CO 2 concentration is then measured by a simple pressure/volume comparison rather than by gas chromatography or spectroscopy. Measurements from Greenland ice core samples give an average value of 280±2 ppM CO 2 for preindustrial samples, demonstrating that the extraction system gives accurate, precise determinations Of CO 2 concentrations. Measurement of δ 13 C from polar ice samples has not been achieved at this time. However, results on standard air samples demonstrate a precision for δ 13 C of less than 0.2 per-thousand at the 95% confidence level

  19. Development of a thermal method for the measurement of elemental carbon

    Energy Technology Data Exchange (ETDEWEB)

    Lavanchy, V.M.H. [Bern Univ. (Switzerland); Baltensperger, U.; Gaeggeler, H.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A thermal method was developed to measure the organic carbon (OC) and elemental carbon (EC) content of atmospheric aerosols. OC is first oxidized under an O{sub 2} flow during a precombustion step and measured with an Non-Dispersive Infrared Analyzer (NDIR). The remaining carbon, defined as EC, is then oxidized at 650{sup o}C. (author) 1 fig., 1 tab., 3 refs.

  20. Direct measurement of the total decay width of the top quark.

    Science.gov (United States)

    Aaltonen, T; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Butti, P; Buzatu, A; Calamba, A; Camarda, S; Campanelli, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Cho, K; Chokheli, D; Clark, A; Clarke, C; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Cremonesi, M; Cruz, D; Cuevas, J; Culbertson, R; d'Ascenzo, N; Datta, M; de Barbaro, P; Demortier, L; Deninno, M; D'Errico, M; Devoto, F; Di Canto, A; Di Ruzza, B; Dittmann, J R; Donati, S; D'Onofrio, M; Dorigo, M; Driutti, A; Ebina, K; Edgar, R; Elagin, A; Erbacher, R; Errede, S; Esham, B; Farrington, S; Fernández Ramos, J P; Field, R; Flanagan, G; Forrest, R; Franklin, M; Freeman, J C; Frisch, H; Funakoshi, Y; Galloni, C; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González López, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gramellini, E; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Han, J Y; Happacher, F; Hara, K; Hare, M; Harr, R F; Harrington-Taber, T; Hatakeyama, K; Hays, C; Heinrich, J; Herndon, M; Hocker, A; Hong, Z; Hopkins, W; Hou, S; Hughes, R E; Husemann, U; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kambeitz, M; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S H; Kim, S B; Kim, Y J; Kim, Y K; Kimura, N; Kirby, M; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Kruse, M; Kuhr, T; Kurata, M; Laasanen, A T; Lammel, S; Lancaster, M; Lannon, K; Latino, G; Lee, H S; Lee, J S; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lipeles, E; Lister, A; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lucà, A; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Marchese, L; Margaroli, F; Marino, P; Martínez, M; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Nigmanov, T; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagliarone, C; Palencia, E; Palni, P; Papadimitriou, V; Parker, W; Pauletta, G; Paulini, M; Paus, C; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Pranko, A; Prokoshin, F; Ptohos, F; Punzi, G; Ranjan, N; Redondo Fernández, I; Renton, P; Rescigno, M; Rimondi, F; Ristori, L; Robson, A; Rodriguez, T; Rolli, S; Ronzani, M; Roser, R; Rosner, J L; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, E E; Schwarz, T; Scodellaro, L; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sliwa, K; Smith, J R; Snider, F D; Song, H; Sorin, V; St Denis, R; Stancari, M; Stentz, D; Strologas, J; Sudo, Y; Sukhanov, A; Suslov, I; Takemasa, K; Takeuchi, Y; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thomson, E; Thukral, V; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Trovato, M; Ukegawa, F; Uozumi, S; Vázquez, F; Velev, G; Vellidis, C; Vernieri, C; Vidal, M; Vilar, R; Vizán, J; Vogel, M; Volpi, G; Wagner, P; Wallny, R; Wang, S M; Waters, D; Wester, W C; Whiteson, D; Wicklund, A B; Wilbur, S; Williams, H H; Wilson, J S; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, H; Wright, T; Wu, X; Wu, Z; Yamamoto, K; Yamato, D; Yang, T; Yang, U K; Yang, Y C; Yao, W-M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Zanetti, A M; Zeng, Y; Zhou, C; Zucchelli, S

    2013-11-15

    We present a measurement of the total decay width of the top quark using events with top-antitop quark pair candidates reconstructed in the final state with one charged lepton and four or more hadronic jets. We use the full Tevatron run II data set of sqrt[s]=1.96  TeV proton-antiproton collisions recorded by the CDF II detector. The top quark mass and the mass of the hadronically decaying W boson are reconstructed for each event and compared with distributions derived from simulated signal and background samples to extract the top quark width (Γtop) and the energy scale of the calorimeter jets with in situ calibration. For a top quark mass Mtop=172.5  GeV/c2, we find 1.10<Γtop<4.05  GeV at 68% confidence level, which is in agreement with the standard model expectation of 1.3 GeV and is the most precise direct measurement of the top quark width to date.

  1. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  2. Measurement of total phospholipids in urine of patients treated with gentamicin.

    Science.gov (United States)

    Saunders, D A; Begg, E J; Kirkpatrick, C M; Yeo, J; Graham, G G; Bailey, R R

    1997-04-01

    The excretion of phospholipids in urine may be a marker of the early renal toxicity of the aminoglycoside antibiotics. Urinary phospholipids are formed in myeloid bodies which develop in the lysosomes of proximal tubules during treatment with the aminoglycosides, and overflow into the urine. Published assays were modified in order to measure the total phospholipid concentrations in human urine. Phospholipids were extracted from freeze-dried urine samples, digested in concentrated sulphuric acid, and the inorganic phosphorus content determined by complexing with ammonium molybdate and measuring the absorbance at 820 nm. Ten septicaemic patients treated with gentamicin for 5-7 days had significantly higher urine phospholipid concentrations than 10 healthy untreated control subjects (P < 0.0001). There was a negative linear relationship between phospholipid excretion and creatinine clearance (r2 = 0.71). In 34 patients with acute pyelonephritis, increased phospholipid concentrations were observed prior to treatment compared with healthy controls (P < 0.001) and did not alter during treatment with gentamicin. However, the phospholipid concentrations decreased significantly after treatment was completed (P < 0.03). These studies suggest that urinary phospholipids may indicate early aminoglycoside toxicity but with poor specificity, as many of the infections being treated may themselves be associated with phospholipiduria.

  3. Status report and measurement of total cross-sections at the Pohang Neutron Facility

    International Nuclear Information System (INIS)

    Kim, G.N.; Meaze, A.K.M.M.H.; Ahmed, H.

    2004-01-01

    We report the status of the Pohang Neutron Facility which consists of an electron linear accelerator, a water-cooled Ta target, and an 11-m time-of-flight path. It has been equipped with a four-position sample changer controlled remotely by a CAMAC data acquisition system, which allows simultaneous accumulation of the neutron time of flight spectra from 4 different detectors. It is possible to measure the neutron total cross-sections in the neutron energy range from 0.1 eV to 100 eV by using the neutron time of flight method. A 6 LiZnS(Ag) glass scintillator was used as a neutron detector. The neutron flight path from the water-cooled Ta target to the neutron detector was 10.81±0.02 m. The background level was determined by using notch-filters of Co, In, Ta, and Cd sheets. In order to reduce the gamma rays from Bremsstrahlung and those from neutron capture, we employed a neutron-gamma separation system based on their different pulse shapes. The present measurements are in general agreement with the evaluated data in ENDF/B-VI. The resonance parameters were extracted from the transmission data from the SAMMY fitting and compared with the previous ones. (author)

  4. Cantilever contribution to the total electrostatic force measured with the atomic force microscope

    International Nuclear Information System (INIS)

    Guriyanova, Svetlana; Golovko, Dmytro S; Bonaccurso, Elmar

    2010-01-01

    The atomic force microscope (AFM) is a powerful tool for surface imaging at the nanometer scale and surface force measurements in the piconewton range. Among long-range surface forces, the electrostatic forces play a predominant role. They originate if the electric potentials of the substrate and of the tip of the AFM cantilever are different. A quantitative interpretation of the AFM signal is often difficult because it depends in a complicated fashion on the cantilever–tip–surface geometry. Since the electrostatic interaction is a long-range interaction, the cantilever, which is many microns from the surface, contributes to the total electrostatic force along with the tip. Here we present results of the electrostatic interaction between a conducting flat surface and horizontal or tilted cantilevers, with and without tips, at various distances from the surface. As addressed in a previous work, we show that the contribution of the cantilever to the overall force cannot be neglected. Based on a predictive model and on 3D confocal measurements, we discuss the influence of the tilting angle of the cantilever

  5. Measuring Total Column Water Vapor by Pointing an Infrared Thermometer at the Sky

    Science.gov (United States)

    Mims, Forrest M., III; Chambers, Lin H.; Brooks, David R.

    2011-01-01

    A 2-year study affirms that the temperature (Tz) indicated by an inexpensive ($20 to $60) IR thermometer pointed at the cloud-free zenith sky provides an approximate indication of the total column water vapor (precipitable water or PW). PW was measured by a MICROTOPS II sun photometer. The coefficient of correlation (r2) of the PW and Tz was 0.90, and the rms difference was 3.2 mm. A comparison of the Tz data with the PW provided by a GPS site 31 km NNE yielded an r2 of 0.79, and an rms difference of 5.8 mm. An expanded study compared Tz from eight IR thermometers with PW at various times during the day and night from 17 May to 18 October 2010, mainly at the Texas site and 10 days at Hawaii's Mauna Loa Observatory (MLO). The best results of this comparison were provided by two IR thermometers models that yielded an r2 of 0.96 and an rms difference with the PW of 2.7 mm. The results of both the ongoing 2-year study and the 5-month instrument comparison show that IR thermometers can measure PW with an accuracy (rms difference/mean PW) approaching 10%, the accuracy typically ascribed to sun photometers.

  6. An Innovative Concept for Spacebased Lidar Measurement of Ocean Carbon Biomass

    Science.gov (United States)

    Hu, Yongxiang; Behrenfeld, Michael; Hostetler, Chris; Pelon, Jacques; Trepte, Charles; Hair, John; Slade, Wayne; Cetinic, Ivona; Vaughan, Mark; Lu, Xiaomei; hide

    2015-01-01

    Beam attenuation coefficient, c, provides an important optical index of plankton standing stocks, such as phytoplankton biomass and total particulate carbon concentration. Unfortunately, c has proven difficult to quantify through remote sensing. Here, we introduce an innovative approach for estimating c using lidar depolarization measurements and diffuse attenuation coefficients from ocean color products or lidar measurements of Brillouin scattering. The new approach is based on a theoretical formula established from Monte Carlo simulations that links the depolarization ratio of sea water to the ratio of diffuse attenuation Kd and beam attenuation C (i.e., a multiple scattering factor). On July 17, 2014, the CALIPSO satellite was tilted 30Âdeg off-nadir for one nighttime orbit in order to minimize ocean surface backscatter and demonstrate the lidar ocean subsurface measurement concept from space. Depolarization ratios of ocean subsurface backscatter are measured accurately. Beam attenuation coefficients computed from the depolarization ratio measurements compare well with empirical estimates from ocean color measurements. We further verify the beam attenuation coefficient retrievals using aircraft-based high spectral resolution lidar (HSRL) data that are collocated with in-water optical measurements.

  7. Integral measurements using the 'sphere method'. The case of carbon

    International Nuclear Information System (INIS)

    Haouat, G.; Lachkar, J.; Patin, Y.; Cocu, F.; Sigaud, J.; Cotten, D.

    1977-01-01

    The time-of-flight spectrum of direct and scattered neutrons with a 10cm diameter carbon sphere. (The direct neutron energy is 14.81MeV, the basic time-of-flight being 6m). The time-of-flight spectrum of the neutrons from T(d,n) 4 He is given in the same experimental conditions (without the carbon sphere) [fr

  8. Measurement and correlation of solubility of carbon dioxide in triglycerides

    International Nuclear Information System (INIS)

    Howlader, Md Shamim; French, William Todd; Toghiani, Hossein; Hartenbower, Ben; Pearson, Larry; DuBien, Janice; Rai, Neeraj

    2017-01-01

    Graphical abstract: Comparison of experimental results with correlation for solubility of CO 2 in triglycerides as a function pressure at two different temperatures of 289.15 and 303.15 K, respectively. - Highlights: • New pressure drop gas apparatus was developed to determine the solubility of gases in liquids. • Solubility of CO 2 in triglycerides was measured at different temperatures and pressures. • Experimental solubility data were correlated using three thermodynamic models. • Enthalpy, entropy and Gibbs energy of dissolution for CO 2 -triglyceride were determined. - Abstract: A new pressure drop solubility gas apparatus was developed to determine the solubility of carbon dioxide in canola oil, a triglyceride consisting primarily of oleic, linoleic, and alpha linoleic acid radicals. Solubility of CO 2 in triglycerides was determined at different temperatures (283.2–303.2 K) and pressures (600–2450 kPa). It was found that the solubility of CO 2 in triglycerides is higher than that of pure water because triglycerides lack strong hydrogen bond networks that exist in liquid water at the ambient conditions. The experimental solubility was correlated using Krichevsky–Kasarnovsky (KK), Mather-Jou (MJ), and Carvalho-Coutinho (CC) correlations. We find that KK and MJ equations can predict the solubility with higher accuracy. The enthalpy and entropy of absorption of CO 2 were calculated using the van’t Hoff plot and were found to be −7.165 kJ.mol −1 , and −28.791 J.mol −1 .K −1 , respectively.

  9. Effect of Sulfites on Antioxidant Activity, Total Polyphenols, and Flavonoid Measurements in White Wine.

    Science.gov (United States)

    Nardini, Mirella; Garaguso, Ivana

    2018-03-09

    Polyphenols content and antioxidant activity are directly related to the quality of wine. Wine also contains sulfites, which are added during the winemaking process. The present study aimed to evaluate the effects of sulfites on the assays commonly used to measure the antioxidant activity and polyphenols and flavonoids content of white wines. The effects of sulfites were explored both in the standard assays and in white wine. The addition of sulfites (at 1-10 μg) in the standard assays resulted in a significant, positive interference in the Folin-Ciocalteu's assay used for polyphenols measurements and in both the Ferric Reducing Antioxidant Power and 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt radical cation decolorization assays, which were used for antioxidant activity evaluation. A negative interference of sulfites (at 1-20 μg) was observed for the colorimetric aluminium-chloride flavonoids assay. The addition of sulfites to organic white wines (at 25-200 mg/L wine) clearly resulted in a significant overestimation of antioxidant activity and polyphenols content, and in an underestimation of flavonoids concentration. To overcome sulfite interferences, white wines were treated with cross-linked polyvinylpyrrolidone. The total polyphenols content and antioxidant activity measurements obtained after polyvinylpyrrolidone treatment were significantly lower than those obtained in the untreated wines. Flavonoids were expected to be higher after polyvinylpyrrolidone treatment, but were instead found to be lower than for untreated wines, suggesting that in addition to sulfites, other non-phenolic reducing compounds were present in white wine and interfered with the flavonoid assay. In view of our results, we advise that a purification procedure should be applied in order to evaluate the quality of white wine.

  10. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.

    Science.gov (United States)

    Nam, Denis; Vajapey, Sravya; Nunley, Ryan M; Barrack, Robert L

    2016-10-01

    The optimal coronal alignment after total knee arthroplasty (TKA) has become an area of increased debate. Sources of variability among investigations include the radiographic technique used for both preoperative surgical planning and postoperative alignment assessments. This study's purpose was to assess the impact of the imaging modality used on the measurement of coronal plane alignment after TKA. A consecutive series of patients undergoing TKA using the same cruciate-retaining prosthesis were included for analysis. Postoperatively, all patients received both a rotationally controlled, scout computed tomography scan and a hip-knee-ankle (HKA) image using the EOS Imaging system (EOS Inc., Paris, France). Two, independent observers measured the HKA angle, and femoral and tibial component alignment from each image. After classifying overall and component alignment as neutral, varus, or valgus, 40.6% (65 of 160) of knees had a discordant alignment classification for HKA, 28.1% (45 of 160) for femoral component alignment, and 26.9% (43 of 160) for tibial component alignment between their computed tomography and EOS images. Overall, 24.4% (39 of 160) of patients had a HKA difference of ≥3° between the 2 images, whereas 18.8% (30 of 160) and 20.0% (32 of 160) of patients had a femoral and tibial component alignment difference of ≥2°, respectively. Significant differences are present when comparing 2 measurement techniques of mechanical alignment after TKA. The impact of imaging modality on postoperative assessments must be accounted for and be consistent when comparing the results of different investigations. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Carbonic Anhydrase Enhanced Carbon Capture: Kinetic Measurements and Pilot Plant Trials

    DEFF Research Database (Denmark)

    Gladis, Arne; Deslauriers, Maria Gundersen; Fosbøl, Philip Loldrup

    In this study the effect of carbonic anhydrase addition on the absorption of CO2 was investigated in a wetted wall column apparatus. Four different solvents: MEA (a primary amine), AMP (a sterically hindered primary amine), MDEA (a tertiary amine) and K2CO3 a carbonate salt solution were tested...

  12. 20 years of Black Carbon measurements in Germany

    Science.gov (United States)

    Kutzner, Rebecca; Quedenau, Jörn; Kuik, Friderike; von Schneidemesser, Erika; Schmale, Julia

    2016-04-01

    Black Carbon (BC) is an important short-lived climate-forcing pollutant contributing to global warming through absorption of sunlight. At the same time, BC, as a component of particulate matter (PM) exerts adverse health effects, like decreased lung function and exacerbated asthma. Globally, anthropogenic emission sources of BC include residential heating, transport, and agricultural fires, while the dominant natural emission sources are wildfires. Despite the various adverse effects of BC, legislation that requires mandatory monitoring of BC concentrations does not currently exist in the European Union. Instead, BC is only indirectly monitored as component of PM10 and PM2.5 (particulate matter with a diameter smaller 10 μm and 2.5 μm). Before the introduction of mandatory PM10 and PM2.5 monitoring in the European Union in 2005 and 2015, respectively, 'black smoke', a surrogate for BC, was a required measurement in Germany from the early 1990s. The annual mean limit value was 14 μg m-3 from 1995 and 8 μg m-3 from 1998 onwards. Many 'black smoke' measurements were stopped in 2004, with the repeal of the regulations obtaining at the time. However, in most German federal states a limited number BC monitoring stations continued to operate. Here we present a synthesis of BC data from 213 stations across Germany covering the period between 1994 and 2014. Due to the lack of a standardized method and respective legislation, the data set is very heterogeneous relying on twelve different measurement methods including chemical, optical, and thermal-optical methods. Stations include locations classified as background, urban-background, industrial and traffic among other types. Raw data in many different formats has been modelled and integrated in a relational database, allowing various options for further data analysis. We highlight results from the year 2009, as it is the year with the largest measurement coverage based on the same measurement method, with 30 stations. In

  13. Ultrasound-assisted extraction for total sulphur measurement in mine tailings

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Adnan Hossain, E-mail: ad_li2@yahoo.com [Department of Civil and Environmental Engineering, University of Western Ontario (Canada); Shang, Julie Q.; Alam, Raquibul [Department of Civil and Environmental Engineering, University of Western Ontario (Canada)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer We develop a total sulphur measuring procedure of mine tailings. Black-Right-Pointing-Pointer Ultrasound is used in the sample pre-treatment process. Black-Right-Pointing-Pointer Full factorial design is applied to identify the best level of effecting factors. - Abstract: A sample preparation method for percentage recovery of total sulphur (%S) in reactive mine tailings based on ultrasound-assisted digestion (USAD) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) was developed. The influence of various methodological factors was screened by employing a two-level and three-factor (2{sup 3}) full factorial design and using KZK-1, a sericite schist certified reference material (CRM), to find the optimal combination of studied factors and %S. Factors such as the sonication time, temperature and acid combination were studied, with the best result identified as 20 min of sonication, 80 Degree-Sign C temperature and 1 ml of HNO{sub 3}:1 ml of HCl, which can achieve 100% recovery for the selected CRM. Subsequently a fraction of the 2{sup 3} full factorial design was applied to mine tailings. The percentage relative standard deviation (%RSD) for the ultrasound method is less than 3.0% for CRM and less than 6% for the mine tailings. The investigated method was verified by X-ray diffraction analysis. The USAD method compared favorably with existing methods such as hot plate assisted digestion method, X-ray fluorescence and LECO Trade-Mark-Sign -CNS method.

  14. X-ray microprobe measurements of the chemical compositions of ALH84001 carbonate globules

    International Nuclear Information System (INIS)

    Flynn, G.J.; Sutton, S.R.; Keller, L.P.

    2004-01-01

    We measured minor element contents of carbonate from ALH84001 and report trends in tbe Ca, V, Mn and Sr in carbonate and the associated magnetite bands. McKay et al. suggested that carbonate globules in the ALH84001 meteorite from Mars contained evidence consistent with the development of bacterial life early in the history of Mars. This result provoked an extensive study of the ALH84001 meteorite. More recently Thomas-Keprta et al. have published a study showing that the magnetite associated with carbonate rims are of the size and shape produced by terrestrial bacteria. This paper has revived interest in ALH84001. The typical ALH84001 carbonate globule consists of four regions: a core of Fe-rich carbonate, a thin magnetite-rich band, a rim of Mn-rich carbonate, and another thin magnetite-rich band. Trace element analysis of each of these phases may allow us to address several important questions about these carbonates: (1) The origin of the magnetite-rich bands in the ALH84001 carbonate globules. If the magnetites are derived from the underlying carbonate through thermal decomposition (as proposed by Golden et al.), then we expect to see 'inherited' trace elements in these magnetite bands. (2) The origin of the rim carbonate, by determining whether the carbonate in the core has the same trace elements as the rim carbonates. (3) The age of the rim carbonate. Borg et al. dated the formation of the rim carbonate using the Rb/Sr chronometer. Borg et al. performed their measurements on an aliquot of what they called a high-Rb, low-Sr carbonate separate from the rim. We previously measured the trace element contents of chips from core and rim carbonates from an ALH84001 carbonate globule using an X-Ray Microprobe on Beamline X26A at the National Synchrotron Light Source. These measurements showed the rim carbonate had a very low Rb content, with Sr>>Rb, inconsistent with the ∼5 ppm Rb reported by Borg et al. in the sample they dated by the Rb/Sr chronometer. The large

  15. The Irminger Sea and the Iceland Sea time series measurements of sea water carbon and nutrient chemistry 1983–2008

    Directory of Open Access Journals (Sweden)

    J. Olafsson

    2010-03-01

    Full Text Available This paper describes the ways and means of assembling and quality controling the Irminger Sea and Iceland Sea time-series biogeochemical data which are included in the CARINA data set. The Irminger Sea and the Iceland Sea are hydrographically different regions where measurements of sea water carbon and nutrient chemistry were started in 1983. The sampling is seasonal, four times a year. The carbon chemistry is studied with measurements of the partial pressure of carbon dioxide in seawater, pCO2, and total dissolved inorganic carbon, TCO2. The carbon chemistry data are for surface waters only until 1991 when water column sampling was initiated. Other measured parameters are salinity, dissolved oxygen and the inorganic nutrients nitrate, phosphate and silicate. Because of the CARINA criteria for secondary quality control, depth >1500 m, the IRM-TS could not be included in the routine QC and the IS-TS only in a limited way. However, with the information provided here, the quality of the data can be assessed, e.g. on the basis of the results obtained with the use of reference materials.

  16. Isocyanate and total inhalable particulate air measurements in the European wood panel industry.

    Science.gov (United States)

    Vangronsveld, E; Berckmans, S; Verbinnen, K; Van Leeuw, C; Bormans, C

    2010-11-01

    It is well known that the use of MDI (methylene diphenyldiisocyanate) as an alternative for formaldehyde-based resins is seen as a responsible option to reduce formaldehyde emissions for CWP (Composite Wood Products) in buildings. However, there are concerns raised regarding the exposure risk of workers. The purpose of this article is to provide the reader with factual information to demonstrate that the use of MDI compared to other agents used in CWP production processes does not pose increased inhalation exposure risks for workers. Personal and area air measurements were carried out at nine Composite Wood Panel plants throughout Europe to assess potential inhalation exposures to MDI and wood dust as Total Inhalable Particulates (TIP). In total, 446 pairs of samples were collected for MDI and TIP of which 283 pairs were personal samples and the remaining 163 pairs were area samples collected at key locations along the production line. This data together with published formaldehyde exposure data has been used to evaluate the exposure safety margin opposite what are considered relevant occupational exposure limits. The methods used for sampling and analysing MDI and TIP are based on internationally accepted methods, i.e. MDHS 25/3 (or ISO 16702) for MDI, and MDHS 14/3 for TIP. The job functions with an increased exposure profile for TIP were the cleaners, drying operators and quality control staff, and for MDI, the cleaners and quality control staff. The areas with an increased exposure profile for TIP are the conveyor area from OSB blender to former area and the OSB press infeed, and for MDI the OSB weigh belt and OSB former bin area. The exposure safety margin opposite the selected exposure limits can be ranked as MDI>TIP>formaldehyde (high margin of safety to low margin of safety), indicating that the use of MDI also reduces the exposure risks to workers during production of CWP compared to formaldehyde. By reducing the airborne TIP concentrations, a respiratory

  17. Towards minimizing measurement uncertainty in total petroleum hydrocarbon determination by GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Saari, E.

    2009-07-01

    Despite tightened environmental legislation, spillages of petroleum products remain a serious problem worldwide. The environmental impacts of these spillages are always severe and reliable methods for the identification and quantitative determination of petroleum hydrocarbons in environmental samples are therefore needed. Great improvements in the definition and analysis of total petroleum hydrocarbons (TPH) were finally introduced by international organizations for standardization in 2004. This brought some coherence to the determination and, nowadays, most laboratories seem to employ ISO/DIS 16703:2004, ISO 9377-2:2000 and CEN prEN 14039:2004:E draft international standards for analysing TPH in soil. The implementation of these methods, however, usually fails because the reliability of petroleum hydrocarbon determination has proved to be poor.This thesis describes the assessment of measurement uncertainty for TPH determination in soil. Chemometric methods were used to both estimate the main uncertainty sources and identify the most significant factors affecting these uncertainty sources. The method used for the determinations was based on gas chromatography utilizing flame ionization detection (GC-FID).Chemometric methodology applied in estimating measurement uncertainty for TPH determination showed that the measurement uncertainty is in actual fact dominated by the analytical uncertainty. Within the specific concentration range studied, the analytical uncertainty accounted for as much as 68-80% of the measurement uncertainty. The robustness of the analytical method used for petroleum hydrocarbon determination was then studied in more detail. A two-level Plackett-Burman design and a D-optimal design were utilized to assess the main analytical uncertainty sources of the sample treatment and GC determination procedures. It was also found that the matrix-induced systematic error may also significantly reduce the reliability of petroleum hydrocarbon determination

  18. Total organic carbon in a soil recovered with sewage sludge and native species of the Atlantic Forest

    Science.gov (United States)

    Mara Lima Goulart, Lívia; Amaral Guerrini, Iraê; Fidalgo de Faria, Marianne; Spada, Grasiela; Proença Nalesso, Pedro Henrique; Willian Carlos, Guilherme

    2017-04-01

    The use of organic waste such as sewage sludge, in the recovery of degraded áreas have shown very satisfactory results, because they are constituted by high contentes of organic matter and nutrients, essential to improve the physical and chemical properties of the soil. Thus, the objective of this study was to verify the total organic carbon (TOC) of a degraded soil, up to a metre deep, after 10 years of application of sewage sludge and planting native species of the Atlantic forest. The experiment was conducted at Fazenda Entre-Rios, owned by Suzano Papel e Celulose, in Itatinga, São Paulo, Brazil. The experiment was designed as randomized block with four replications, six doses of sewage sludge (0, 2.5, 5, 10, 15 and 20 t ha-1), conventional chemical fertilizer and only with potassium application, totaling eight treatments. Samples were collected every 20 cm (0-20, 20-40, 40-60, 60-80 and 80-100 cm) until reaching a metre deep. Ten years after trial deployment, the sewage sludge application in degraded soil was significantly influenced the TOC at all depths sampled. The highest values of the COT were observed in plots that received 15 and 20 t ha-1 of sewage sludge, in all depths sampled, except for the layer of 80-100 cm, which presented the highest average COT in the treatment with 10 t ha-1 of residue. As observed for all treatments, the highest TOC averages were observed in the superficial layers of the soil (0-20 and 20-40 cm). The sewage sludge application is useful to recover degraded soils, as it improving their chemical characteristics and showing to be a good alternative to the final destination of this residue.

  19. A Systematic Review of Measurement Properties of Patient-Reported Outcome Measures Used in Patients Undergoing Total Knee Arthroplasty.

    Science.gov (United States)

    Gagnier, Joel J; Mullins, Megan; Huang, Hsiaomin; Marinac-Dabic, Danica; Ghambaryan, Anna; Eloff, Benjamin; Mirza, Faisal; Bayona, Manuel

    2017-05-01

    While clinical research on total knee arthroplasty (TKA) outcomes is prevalent in the literature, studies often have poor methodological and reporting quality. A high-quality patient-reported outcome instrument is reliable, valid, and responsive. Many studies evaluate these properties, but none have done so with a systematic and accepted method. The objectives of this study were to identify patient-reported outcome measures (PROMs) for TKA, and to critically appraise, compare, and summarize their psychometric properties using accepted methods. MEDLINE, EMBASE, SCOPUS, Web of Science, PsycINFO, and SPORTDiscus were systematically searched for articles with the following inclusion criteria: publication before December 2014, English language, non-generic PRO, and evaluation in the TKA population. Methodological quality and evidence of psychometric properties were assessed with the COnsensus-based standards for the selection of health Status Measurement INstruments (COSMIN) checklist and criteria for psychometric evidence proposed by the COSMIN group and Terwee et al. One-hundred fifteen studies on 32 PROMs were included in this review. Only the Work, Osteoarthritis or joint-Replacement Questionnaire, the Oxford Knee Score, and the Western Ontario and McMaster Universities Arthritis Index had 4 or more properties with positive evidence. Most TKA PROMs have limited evidence for their psychometric properties. Although not all the properties were studied, the Work, Osteoarthritis or joint-Replacement Questionnaire, with the highest overall ratings, could be a useful PROM for evaluating patients undergoing TKA. The methods and reporting of this literature can improve by following accepted guidelines. Published by Elsevier Inc.

  20. Measurement of total calcium in neurons by electron probe X-ray microanalysis.

    Science.gov (United States)

    Pivovarova, Natalia B; Andrews, S Brian

    2013-11-20

    In this article the tools, techniques, and instruments appropriate for quantitative measurements of intracellular elemental content using the technique known as electron probe microanalysis (EPMA) are described. Intramitochondrial calcium is a particular focus because of the critical role that mitochondrial calcium overload plays in neurodegenerative diseases. The method is based on the analysis of X-rays generated in an electron microscope (EM) by interaction of an electron beam with the specimen. In order to maintain the native distribution of diffusible elements in electron microscopy specimens, EPMA requires "cryofixation" of tissue followed by the preparation of ultrathin cryosections. Rapid freezing of cultured cells or organotypic slice cultures is carried out by plunge freezing in liquid ethane or by slam freezing against a cold metal block, respectively. Cryosections nominally 80 nm thick are cut dry with a diamond knife at ca. -160 °C, mounted on carbon/pioloform-coated copper grids, and cryotransferred into a cryo-EM using a specialized cryospecimen holder. After visual survey and location mapping at ≤-160 °C and low electron dose, frozen-hydrated cryosections are freeze-dried at -100 °C for ~30 min. Organelle-level images of dried cryosections are recorded, also at low dose, by means of a slow-scan CCD camera and subcellular regions of interest selected for analysis. X-rays emitted from ROIs by a stationary, focused, high-intensity electron probe are collected by an energy-dispersive X-ray (EDX) spectrometer, processed by associated electronics, and presented as an X-ray spectrum, that is, a plot of X-ray intensity vs. energy. Additional software facilitates: 1) identification of elemental components by their "characteristic" peak energies and fingerprint; and 2) quantitative analysis by extraction of peak areas/background. This paper concludes with two examples that illustrate typical EPMA applications, one in which mitochondrial calcium analysis

  1. Spatial distribution and offshore export of total organic carbon along the eastern boundary of the Subtropical North Pacific

    Directory of Open Access Journals (Sweden)

    C.G. Castro

    2011-12-01

    Full Text Available Data collected in February, 2003, along the upper continental slope of western North America between Monterey Bay, California (37°N, 122°W, and Cabo San Lucas, Mexico (23°N, 118°W, document, for the first time, the alongshore distribution of total organic carbon (TOC. Highest TOC concentrations (>70 µM were observed for waters above the nitracline and associated with both California Current and southern surface waters. The northward advection of tropical waters in the California Undercurrent did not have any discernible impact on TOC distributions. An estimate of the average rate at which TOC in surface waters was exported offshore by Ekman transport in February 2003 was 1.73 × 103 kg C yr−1 for each meter of coastline. The offshore flux estimate is thought to be conservative with respect to the annual mean offshore flux because the offshore Ekman transport and primary production increase in late spring and early summer and the contribution of upwelling filaments has not been considered. Analysis of TOC contributions to pelagic respiration suggested that TOC accounted for 45% of the oxygen decrease in southern oxic waters. In California Current and oxygen minimum zone waters, TOC did not contribute to pelagic respiration.

  2. Total protein

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003483.htm Total protein To use the sharing features on this page, please enable JavaScript. The total protein test measures the total amount of two classes ...

  3. Friction in total hip joint prosthesis measured in vivo during walking.

    Science.gov (United States)

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  4. Detection of Total Knee Arthroplasties at Airport Security Checkpoints: How Do Updated Security Measures Affect Patients?

    Science.gov (United States)

    Issa, Kimona; Pierce, Todd P; Gwam, Chukwuweieke; Goljan, Peter; Festa, Anthony; Scillia, Anthony J; Mont, Michael A

    2017-07-01

    Airport security measures continue to be updated with the incorporation of the new body scanners and automatic target recognition software. The purpose of this study was analyze the incidence of: (1) triggering the security alarm; (2) extra security searches; (3) perceived inconvenience; and (4) presence of other surgical hardware in those who underwent total knee arthroplasty (TKA) and passed through airport security. A questionnaire was given to 125 consecutive patients with a TKA. Those who passed through airport security after January 2014 were considered for inclusion. A questionnaire was administered that addressed the number of encounters with airport security, metal detector activation, additional screening procedures, and perceived inconvenience. Out of the 125 patients, 53 met inclusion criteria. Out of the 53 patients, 20 (38%) reported that their prosthesis triggered a metal detector. Out of the 20 patients, 8 (40%) who reported triggering of metal detectors also reported the presence of surgical hardware elsewhere in the body. Eighteen of the 53 patients (34%) believed having a TKA was inconvenient for airplane travel. Compared with the historical cohort, alarms were triggered in 70 of 97 patients ( p  = 0.0001) and 50 of 97 reported inconvenience when traveling ( n  = 50 of 97 patients; p  = 0.04). The incidences of those who underwent TKA triggering alarms and perceiving inconvenience when passing through airport security have decreased from previously published studies. This is most likely due to the recent updates and modifications to screening. As these security measures are modified and implant designs continue to evolve, this is an area of investigation that should continue. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Friction in total hip joint prosthesis measured in vivo during walking.

    Directory of Open Access Journals (Sweden)

    Philipp Damm

    Full Text Available Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06 at contralateral toe off to 0.06 (0.04 to 0.08 at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23 at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W. Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  6. Measurements and analysis of the 127I and 129I neutron capture and total cross sections

    International Nuclear Information System (INIS)

    Noguere, G.

    2005-01-01

    Most of the experimental work on the interaction of neutrons with matter has focused on materials important to reactor physics and reactor structures. By comparison, the corresponding data for minor actinides or long-lived fission products are poor. A significant demand has developed for improved neutron cross-section data of these little-studied nuclides due to the surge of interest in the transmutation of nuclear waste. With 400 kg of 129 I produced yearly in the reactors of the EU countries and a very long β - half-life of 1.57 x 10 7 years, iodine requires disposal strategies that will isolate this isotope from the environment for long periods of time. Therefore, 129 I is potentially a key long-lived fission product for transmutation applications, since 129 I transmutes in 130 I after a single neutron capture and decays to 130 Xe with a 12.36 h half-life. Accurate capture cross sections would help to reduce uncertainties in waste management concepts. For that purpose, Time-Of-Flight measurements covering the [0.5 eV-100 keV] energy range have been carried out at the 150 MeV pulsed neutron source GELINA of the Institute for Reference Materials and Measurements (IRMM). Two types of experiments have been performed at the IRMM, namely capture and transmission experiments. They are respectively related to the neutron capture and total cross sections. Since the PbI 2 samples used in this work contain natural and radioactive iodine, extensive measurements of 129 I have been carried out under the same experimental conditions as for the 129 I. The data reduction process was performed with the AGS system, and the resonance parameters were extracted with the SAMMY and REFIT shape analysis codes. In a last step, the parameters have been converted into ENDF-6 format and processed with the NJOY code to produce point-wise and multigroup cross sections, as well as MCNP and ERANOS libraries. (author)

  7. Measurements of carbon dioxide and heat fluxes during monsoon ...

    Indian Academy of Sciences (India)

    An increase in carbon dioxide (CO2) concentrations in the atmosphere due to ... The changes in land ... the air quality and climate models. 2. ... soon period of 2011 as a part Cloud Aerosol .... density effects due to heat and water vapour trans-.

  8. Development of Performance Measures for the Implementation of Total Quality Management in Indian Industry

    OpenAIRE

    Perminderjit Singh; Sukhvir Singh

    2015-01-01

    Total Quality Management (TQM) refers to management methods used to enhance quality and productivity in business organizations. Total Quality Management (TQM) has become a frequently used term in discussions concerning quality. Total Quality management has brought rise in demands on the organizations policy and the customers have gained more importance in the organizations focus. TQM is considered as an important management tool, which helps the organizations to satisfy their customers. In pr...

  9. Total-ozone and nitrogen-dioxide measurements at the Molodezhnaya and Mirnyi Antarctic stations during spring 1987-autumn 1988

    Energy Technology Data Exchange (ETDEWEB)

    Elokhov, A.S.; Gruzdev, A.N. (AN SSSR, Institut Fiziki Atmosfery, Moscow, (USSR))

    1991-09-01

    Results of measurements of the total-ozone and NO2 content during November-December (Molodezhnaya) and February-April 1988 (Mirnyi) are reported. During the November-December period an irregular total ozone increase was observed, which characterized the filling up of the ozone hole. Stratospheric warming and the total NO2 increase occurred simultaneously. During the summer-autumn period the total NO2 content decreased gradually. The evening total NO2 content was systematically greater than the morning one, which reflects changes in the NO2 abundance from day to night. 12 refs.

  10. NMR experiments for the measurement of proton-proton and carbon-carbon residual dipolar couplings in uniformly labelled oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Pastor, Manuel [Universidad de Santiago de Compostela, Laboratorio Integral de Estructura de Biomoleculas Jose. R. Carracido, Unidade de Resonancia Magnetica, RIAIDT (Spain)], E-mail: mmartin@usc.es; Canales-Mayordomo, Angeles; Jimenez-Barbero, Jesus [Departamento de Estructura y funcion de proteinas, Centro de Investigaciones Biologicas, CSIC (Spain)], E-mail: jjbarbero@cib.csic.es

    2003-08-15

    A 2D-HSQC-carbon selective/proton selective-constant time COSY, 2D-HSQC-(sel C, sel H)-CT COSY experiment, which is applicable to uniformly {sup 13}C isotopically enriched samples (U-{sup 13}C) of oligosaccharides or oligonucleotides is proposed for the measurement of proton-proton RDC in crowded regions of 2D-spectra. In addition, a heteronuclear constant time-COSY experiment, {sup 13}C-{sup 13}C CT-COSY, is proposed for the measurement of one bond carbon-carbon RDC in these molecules. These two methods provide an extension, to U-{sup 13}C molecules, of the original homonuclear constant time-COSY experiment proposed by Tian et al. (1999) for saccharides. The combination of a number of these RDC with NOE data may provide the method of choice to study oligosaccharide conformation in the free and receptor-bound state.

  11. A Carbon Flux Super Site. New Insights and Innovative Atmosphere-Terrestrial Carbon Exchange Measurements and Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Leclerc, Monique Y. [The University of Georgia Research Foundation, Athens, GA (United States)

    2014-11-17

    This final report presents the main activities and results of the project “A Carbon Flux Super Site: New Insights and Innovative Atmosphere-Terrestrial Carbon Exchange Measurements and Modeling” from 10/1/2006 to 9/30/2014. It describes the new AmeriFlux tower site (Aiken) at Savanna River Site (SC) and instrumentation, long term eddy-covariance, sodar, microbarograph, soil and other measurements at the site, and intensive field campaigns of tracer experiment at the Carbon Flux Super Site, SC, in 2009 and at ARM-CF site, Lamont, OK, and experiments in Plains, GA. The main results on tracer experiment and modeling, on low-level jet characteristics and their impact on fluxes, on gravity waves and their influence on eddy fluxes, and other results are briefly described in the report.

  12. Micrometeorological measurements of ammonia and total reactive nitrogen exchange over semi-natural peatland

    Science.gov (United States)

    Brümmer, Christian; Richter, Undine; Schrader, Frederik; Kutsch, Werner

    2015-04-01

    Intensive agriculture generates a substantial atmospheric burden for nitrogen-limited ecosystems such as peatlands when the latter are located in close vicinity to arable sites and animal houses. The exchange of reactive nitrogen compounds between these bog ecosystems and the atmosphere is still not very well understood due to the lack of suitable measurement techniques. With recent advancements in laser spectrometry, we used a quantum cascade laser spectrometer as well as a custom-built total reactive atmospheric nitrogen (ΣNr) converter (TRANC) coupled to a fast-response chemiluminescence detector to measure NH3 and ΣNr concentrations, respectively. The analyzers' high temporal resolution allowed for determination of the respective nitrogen exchange within eddy covariance-based setups. Field campaigns were conducted at a northwestern German peatland site that is surrounded by an area of highly fertilized agricultural land and intensive livestock production (~1 km distance). The field site is part of a natural park with a very small remaining protected zone of less than 2 km x 2 km. Ammonia and ΣNr concentrations were highly variable between 2 to 110 ppb and 10 to 120 ppb, respectively. Peak values coincided with main fertilization periods on the neighboring agricultural land in early spring and fall. The trend in weekly averaged ΣNr concentrations from TRANC measurements was in good agreement with results from KAPS denuder filter systems when the latter were combined with the missing and apparently highly variable NOx contribution. Wind direction and land use in the closer vicinity clearly regulated whether ΣNr concentrations were NH3 or NOx-dominated. Ammonia uptake rates between 40 ng N m-2 s-1 and near-neutral exchange were observed. The cumulative net uptake for the period of investigation was ~700 g N ha-1 resulting in a dry net deposition of ~4 kg N ha-1 when extrapolated to an entire year, whereas KAPS denuder measurements in combination with dry

  13. Standardisation of a European measurement method for organic carbon and elemental carbon in ambient air: results of the field trial campaign and the determination of a measurement uncertainty and working range.

    Science.gov (United States)

    Brown, Richard J C; Beccaceci, Sonya; Butterfield, David M; Quincey, Paul G; Harris, Peter M; Maggos, Thomas; Panteliadis, Pavlos; John, Astrid; Jedynska, Aleksandra; Kuhlbusch, Thomas A J; Putaud, Jean-Philippe; Karanasiou, Angeliki

    2017-10-18

    The European Committee for Standardisation (CEN) Technical Committee 264 'Air Quality' has recently produced a standard method for the measurements of organic carbon and elemental carbon in PM 2.5 within its working group 35 in response to the requirements of European Directive 2008/50/EC. It is expected that this method will be used in future by all Member States making measurements of the carbonaceous content of PM 2.5 . This paper details the results of a laboratory and field measurement campaign and the statistical analysis performed to validate the standard method, assess its uncertainty and define its working range to provide clarity and confidence in the underpinning science for future users of the method. The statistical analysis showed that the expanded combined uncertainty for transmittance protocol measurements of OC, EC and TC is expected to be below 25%, at the 95% level of confidence, above filter loadings of 2 μg cm -2 . An estimation of the detection limit of the method for total carbon was 2 μg cm -2 . As a result of the laboratory and field measurement campaign the EUSAAR2 transmittance measurement protocol was chosen as the basis of the standard method EN 16909:2017.

  14. Measurements of Carbon Dioxide and Carbon Monoxide at High Spatial and Temporal Resolution in an Urban Environment

    Science.gov (United States)

    Rella, C.; Jacobson, G. A.; Crosson, E.

    2011-12-01

    The ability to take inventory of critical greenhouse gases such as carbon dioxide and methane and quantify their sources and sinks is essential for understanding the atmospheric drivers to global climate change. "Top down" inversion measurements and models are used to quantify net carbon fluxes into the atmosphere. The overall carbon fluxes are determined by combining remote measurements of carbon dioxide concentrations with complex atmospheric transport models, and these emissions measurements are compared to "bottoms-up" predictions based on detailed inventories of the sources and sinks of carbon, both anthropogenic and biogenic in nature. At smaller distance scales, such as that of a city or even smaller, the basic framework underpinning the inversion modeling technique begins to break down: atmospheric transport models, which are well understood at a length scale of 100 km, work poorly or not at all at a 100m distance scale. Furthermore, the variability of the emissions sources in space (e.g., factories, highways, residences) and time (rush hours, factory shifts and shutdowns, residential energy usage variability during the day and over the year) complicate the interpretation of the measured signals. In this paper we present detailed, high spatial- and temporal-resolution greenhouse gas measurements in Silicon Valley, CA. The results of two experimental campaigns are presented: a 10m urban 'tower' and ground-based mobile mapping measurements. In both campaigns, real-time carbon dioxide data are combined with real-time carbon monoxide measurements to partition the observed CO2 concentrations between anthropogenic and biogenic sources . The urban tower measurements are made continuously over a period of many weeks. The mobile maps of the vicinity of the urban tower are taken repeatedly over a period of several days, and at different times of the day and under different atmospheric conditions, to assess the robustness and repeatability of the maps. Initial

  15. Facilitating Low-Carbon Living? A Comparison of Intervention Measures in Different Community-Based Initiatives

    Directory of Open Access Journals (Sweden)

    Martina Schäfer

    2018-04-01

    Full Text Available The challenge of facilitating a shift towards sustainable housing, food and mobility has been taken up by diverse community-based initiatives ranging from “top-down” approaches in low-carbon municipalities to “bottom-up” approaches in intentional communities. This paper compares intervention measures in four case study areas belonging to these two types, focusing on their potential of re-configuring daily housing, food, and mobility practices. Taking up critics on dominant intervention framings of diffusing low-carbon technical innovations and changing individual behavior, we draw on social practice theory for the empirical analysis of four case studies. Framing interventions in relation to re-configuring daily practices, the paper reveals differences and weaknesses of current low-carbon measures of community-based initiatives in Germany and Austria. Low-carbon municipalities mainly focus on introducing technologies and offering additional infrastructure and information to promote low-carbon practices. They avoid interfering into residents’ daily lives and do not restrict carbon-intensive practices. In contrast, intentional communities base their interventions on the collective creation of shared visions, decisions, and rules and thus provide social and material structures, which foster everyday low-carbon practices and discourage carbon-intensive ones. The paper discusses the relevance of organizational and governance structures for implementing different types of low-carbon measures and points to opportunities for broadening current policy strategies.

  16. Comparison of Transcutaneous Bilirubin Measurement With Total Serum Bilirubin Levels in Preterm Neonates Receiving Phototherapy.

    Science.gov (United States)

    Pendse, Amruta; Jasani, Bonny; Nanavati, Ruchi; Kabra, Nandkishor

    2017-08-15

    To compare transcutaneous bilirubin with total serum bilirubin in preterm neonates after initiation of phototherapy. Jaundice was assessed in 30 preterm neonates with transcutaneous bilirubin and total serum bilirubin before initiation of phototherapy and at 12 hr after initiation of phototherapy. A photo-occlusive patch was applied over the sternum. Transcutaneous bilirubin has a good correlation with total serum bilirubin after initiation of phototherapy. (r=0.918, Pbilirubin at 28-32 weeks of gestation (r = 0.97) was better correlated with total serum bilirubin than those at 32-37 weeks (r =0.88). The correlation was better for neonates 72 hours of age (r = 0.82). Transcutaneous bilirubin correlates significantly with total serum bilirubin at the patched sternal site after initiation of phototherapy in preterm neonates.

  17. Simultaneous measurement of milk intake and total energy expenditure in mixed-fed infants: Methodological approach and prediction of total body water

    International Nuclear Information System (INIS)

    Wells, J.C.K.; Davies, P.S.W.; Coward, W.A.

    2000-01-01

    Evaluation of the energy metabolism that underlies the new WHO breast-fed growth reference requires simultaneous measurements of milk volume intake (MVI) and total energy expenditure (TEE) by stable isotope methodologies. In young infants, such data is collected without difficulty using the dose-to-the-infant method. In older infants, where breast-milk is supplemented with non-milk foods, MVI must be measured by dosing the mother instead of the infant. This procedure would interfere with a simple measurement of infant TEE using the standard dose-to-the-infant method. Theoretically, this difficulty can be resolved by dosing the mother with deuterium and the infant with 18-oxygen, and using curve-peeling methods to calculate the infant deuterium kinetics. We propose to ascertain whether such an approach is viable in practice, such that MVI, TEE and body composition could all be measured simultaneously in mixed-fed infants. Where MVI in older infants is measured on its own, there is a need to predict infant body water in order to estimate the deuterium dilution space. Using a database of 234 infants aged 1.5 to 12 months, we provide new predictive equations by which such values may be obtained. (author)

  18. Measurements and Factors That Influence the Carbon Capability of Urban Residents in China

    Directory of Open Access Journals (Sweden)

    Qianwen Li

    2018-04-01

    Full Text Available Due to the rapid growth in residential energy consumption, there is an urgent need to reduce carbon emissions from the consumer side, which requires improvements in the carbon capability of urban residents. In this study, previous investigations of carbon capability were analyzed and classified into four dimensions: carbon knowledge capability, carbon motivation capability, carbon behavior capability, and carbon management capability. According to grounded theory, a quantitative research model was constructed of the carbon capability of urban residents in Jiangsu, which was used to conduct a questionnaire survey. SPSS 19.0 and LatentGOLD were employed to process the questionnaire data and the carbon capability of the residents was evaluated. The results showed that the residents of Jiangsu Province could be divided into six groups based on their different carbon capabilities, where these six major groups accounted for 28.19%, 21.21%, 18.33%, 15.84%, 9.88%, and 6.55% of the total sample. Gender, age, occupation, and educational level had significant effects on the carbon capabilities of residents, whereas the annual household income and household population had no significant effects. According to the characteristics of each cluster based on the four carbon capability dimensions, the six clusters were designated as “balanced steady cluster”, “self-restraint cluster”, “fully backward cluster”, “comprehensive leading cluster”, “slightly cognitive cluster”, and “restrain others cluster”. Quantitative analysis showed that 61.93% of the residents of Jiangsu reached the qualified rate for the carbon capability but the excellent rate was only 15.84%. Relevant policy implications are suggested based on these conclusions.

  19. Total belowground carbon flux in subalpine forests is related to leaf area index, soil nitrogen, and tree height

    Science.gov (United States)

    Berryman, Erin Michele; Ryan, Michael G.; Bradford, John B.; Hawbaker, Todd J.; Birdsey, R.

    2016-01-01

    In forests, total belowground carbon (C) flux (TBCF) is a large component of the C budget and represents a critical pathway for delivery of plant C to soil. Reducing uncertainty around regional estimates of forest C cycling may be aided by incorporating knowledge of controls over soil respiration and TBCF. Photosynthesis, and presumably TBCF, declines with advancing tree size and age, and photosynthesis increases yet C partitioning to TBCF decreases in response to high soil fertility. We hypothesized that these causal relationships would result in predictable patterns of TBCF, and partitioning of C to TBCF, with natural variability in leaf area index (LAI), soil nitrogen (N), and tree height in subalpine forests in the Rocky Mountains, USA. Using three consecutive years of soil respiration data collected from 22 0.38-ha locations across three 1-km2 subalpine forested landscapes, we tested three hypotheses: (1) annual soil respiration and TBCF will show a hump-shaped relationship with LAI; (2) variability in TBCF unexplained by LAI will be related to soil nitrogen (N); and (3) partitioning of C to TBCF (relative to woody growth) will decline with increasing soil N and tree height. We found partial support for Hypothesis 1 and full support for Hypotheses 2 and 3. TBCF, but not soil respiration, was explained by LAI and soil N patterns (r2 = 0.49), and the ratio of annual TBCF to TBCF plus aboveground net primary productivity (ANPP) was related to soil N and tree height (r2 = 0.72). Thus, forest C partitioning to TBCF can vary even within the same forest type and region, and approaches that assume a constant fraction of TBCF relative to ANPP may be missing some of this variability. These relationships can aid with estimates of forest soil respiration and TBCF across landscapes, using spatially explicit forest data such as national inventories or remotely sensed data products.

  20. Estimating Global Seafloor Total Organic Carbon Using a Machine Learning Technique and Its Relevance to Methane Hydrates

    Science.gov (United States)

    Lee, T. R.; Wood, W. T.; Dale, J.

    2017-12-01

    Empirical and theoretical models of sub-seafloor organic matter transformation, degradation and methanogenesis require estimates of initial seafloor total organic carbon (TOC). This subsurface methane, under the appropriate geophysical and geochemical conditions may manifest as methane hydrate deposits. Despite the importance of seafloor TOC, actual observations of TOC in the world's oceans are sparse and large regions of the seafloor yet remain unmeasured. To provide an estimate in areas where observations are limited or non-existent, we have implemented interpolation techniques that rely on existing data sets. Recent geospatial analyses have provided accurate accounts of global geophysical and geochemical properties (e.g. crustal heat flow, seafloor biomass, porosity) through machine learning interpolation techniques. These techniques find correlations between the desired quantity (in this case TOC) and other quantities (predictors, e.g. bathymetry, distance from coast, etc.) that are more widely known. Predictions (with uncertainties) of seafloor TOC in regions lacking direct observations are made based on the correlations. Global distribution of seafloor TOC at 1 x 1 arc-degree resolution was estimated from a dataset of seafloor TOC compiled by Seiter et al. [2004] and a non-parametric (i.e. data-driven) machine learning algorithm, specifically k-nearest neighbors (KNN). Built-in predictor selection and a ten-fold validation technique generated statistically optimal estimates of seafloor TOC and uncertainties. In addition, inexperience was estimated. Inexperience is effectively the distance in parameter space to the single nearest neighbor, and it indicates geographic locations where future data collection would most benefit prediction accuracy. These improved geospatial estimates of TOC in data deficient areas will provide new constraints on methane production and subsequent methane hydrate accumulation.

  1. Total organic carbon and humus fractions in restored soils from limestone quarries in semiarid climate, SE Spain

    Science.gov (United States)

    Luna Ramos, Lourdes; Miralles Mellado, Isabel; Ángel Domene Ruiz, Miguel; Solé Benet, Albert

    2016-04-01

    Mining activities generate erosion and loss of plant cover and soil organic matter (SOM), especially in arid and semiarid Mediterranean regions. A precondition for ecosystem restoration in such highly disturbed areas is the development of functional soils with sufficient organic matter. But the SOM quality is also important to long-term C stabilization. The resistance to biodegradation of recalcitrant organic matter fractions has been reported to depend on some intrinsic structural factors of humic acid substances and formation of amorphous organo-mineral recalcitrant complexes. In an experimental soil restoration in limestone quarries in the Sierra de Gádor (Almería), SE Spain, several combinations of organic amendments (sewage sludge and compost from domestic organic waste) and mulches (gravel and woodchip) were added in experimental plots using a factorial design. In each plot, 75 native plants (Anthyllis cytisoides, A. terniflora and Macrochloa tenacissima) were planted and five years after the start of the experiment total organic carbon (TOC), physico-chemical soil properties and organic C fractions (particulate organic matter, H3PO4-fulvic fraction, fulvic acids (FA), humic acids (HA) and humin) were analyzed. We observed significant differences between treatments related to the TOC content and the HA/FA ratio. Compost amendments increased the TOC, HA content and HA/FA ratio, even higher than in natural undisturbed soils, indicating an effective clay humus-complex pointing to progressively increasing organic matter quality. Soils with sewage sludge showed the lowest TOC and HA/FA ratio and accumulated a lower HA proportion indicating poorer organic matter quality and comparatively lower resilience than in natural soils and soils amended with compost.

  2. The budget between transportation and accumulation of organic carbon and total nitrogen in black soil at a sloping farmland

    International Nuclear Information System (INIS)

    Fang Huajun; Zhang Xiaoping; Liang Aizhen

    2006-01-01

    Based on the rate of soil redistribution at a sloping farmland using 137 Cs tracer technique and spatial variation of soil organic carbon (SOC) and total nitrogen (TN), the spatial distribution of SOC and TN loss and the budget between transportation and accumulation for recently 50 years was calculated. The results showed that the rate of soil redistribution ranged from -24.61 t/hm 2 /a to 33.56 t/hm 2 /a, most of study area was in medium and weakly erosion phase and accounted for 83.66%; and the area of soil deposition accounted for 15.62%; The variation of the loss of SOC and TN was consistent with that of soil redistribution, shoulder-slope had the most serious loss with the rate of 407.57 kg/hm 2 /a for SOC and 39.94 kg/hm 2 /a for TN, back-slope and summit had the secondly loss with the average rate of 244.2 kg/hm 2 /a for SOC and -20.56 kg/hm 2 /a for TN. For the whole area, relative loss of SOC and TN more than 50% accounted for 10.45% and 11.21%, respectively; The net loss of sediment in the study area was 45.54 t/a for recent 48 years, among which SOC and TN were 612.62 kg/a and 47.20 kg/a, respectively, which was 52% more than that of without consideration of the enrichment of sediment on soil organic matter. (authors)

  3. Short-term measurement of carbon isotope fractionation in plants

    International Nuclear Information System (INIS)

    O'Leary, M.H.; Treichel, I.; Rooney, M.

    1986-01-01

    Combustion-based studies of the carbon-13 content of plants give only an integrated, long-term value for the isotope fractionation associated with photosynthesis. A method is described here which permits determination of this isotope fractionation in 2 to 3 hours. To accomplish this, the plant is enclosed in a glass chamber, and the quantity and isotopic content of the CO 2 remaining in the atmosphere are monitored during photosynthesis. Isotope fractionation studies by this method give results consistent with what is expected from combustion studies of C 3 , C 4 , and Crassulacean acid metabolism plants. This method will make possible a variety of new studies of environmental and species effects in carbon isotope fractionation

  4. Activated carbon as a pseudo-reference electrode for electrochemical measurement inside concrete

    NARCIS (Netherlands)

    Abbas, Yawar; Olthuis, Wouter; van den Berg, Albert

    2015-01-01

    The application of Kynol based activated carbon (KAC) as a pseudo-reference electrode for potentiometric measurement inside concrete is presented. Due to its high surface area the activated carbons has a large electrical double layer capacitance (EDLC > 50 F g(-1)) and are used as electrode material

  5. Combining multiple ecosystem productivity measurements to constrain carbon uptake estimates in semiarid grasslands and shrublands

    Science.gov (United States)

    Maurer, G. E.; Krofcheck, D. J.; Collins, S. L.; Litvak, M. E.

    2016-12-01

    Recent observational and modeling studies have indicated that semiarid ecosystems are more dynamic contributors to the global carbon budget than once thought. Semiarid carbon fluxes, however, are generally small, with high interannual and spatial variability, which suggests that validating their global significance may depend on examining multiple productivity measures and their associated uncertainties and inconsistencies. We examined ecosystem productivity from eddy covariance (NEE), harvest (NPP), and terrestrial biome models (NEPm) at two very similar grassland sites and one creosote shrubland site in the Sevilleta National Wildlife Refuge of central New Mexico, USA. Our goal was to assess site and methodological correspondence in annual carbon uptake, patterns of interannual variability, and measurement uncertainty. One grassland site was a perennial carbon source losing 30 g C m-2 per year on average, while the other two sites were carbon sources or sinks depending on the year, with average net uptake of 5 and 25 g C m-2 per year at the grassland and shrubland site, respectively. Uncertainty values for cumulative annual NEE overlapped between the three sites in most years. When combined, aboveground and belowground annual NPP measurements were 15% higher than annual NEE values and did not confirm a loss of carbon at any site in any year. Despite differences in mean site carbon balance, year-to-year changes in cumulative annual NEE and NPP were similar at all sites with years 2010 and 2013 being favorable for carbon uptake and 2011 and 2012 being unfavorable at all sites. Modeled NEPm data for a number of nearby grid cells reproduced only a fraction of the observed range in carbon uptake and its interannual variability. These three sites are highly similar in location and climate and multiple carbon flux measurements confirm the high interannual variability in carbon flux. The exact magnitude of these fluxes, however, remains difficult to discern.

  6. A chronology of the PY608E–PC sediment core (Lake Pumoyum Co, southern Tibetan Plateau) based on radiocarbon dating of total organic carbon

    International Nuclear Information System (INIS)

    Watanabe, Takahiro; Nakamura, Toshio; Matsunaka, Tetsuya; Nara, Fumiko Watanabe; Zhu Liping; Wang Junbo; Kakegawa, Takeshi; Nishimura, Mitsugu

    2013-01-01

    Paleoclimatic records from the Tibetan Plateau provide important clues for understanding the Asian monsoon and Asian climate systems. To reconstruct climatic and environmental changes in the southern Tibetan Plateau, a 3.77-m-long sediment core (PY608E–PC) was taken from the southeastern part of Lake Pumoyum Co in August 2006. Because terrestrial plant residues are extremely rare in this core, we performed radiocarbon dating on the total organic carbon fraction. We also estimated the old carbon effect and radiocarbon reservoir age of the total organic carbon fraction. Using these estimates, we propose a new radiocarbon chronology for past climatic changes from ca. 12,500 to 700 cal BP. The linear sedimentation rate of the core was founded to be constant at 32.0 cm/kyr, indicating stable sedimentation conditions in Lake Pumoyum Co from the period of the Younger Dryas to the Holocene.

  7. A chronology of the PY608E-PC sediment core (Lake Pumoyum Co, southern Tibetan Plateau) based on radiocarbon dating of total organic carbon

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Takahiro, E-mail: twatanabe@geo.kankyo.tohoku.ac.jp [Graduate School of Environmental Studies, Tohoku University, 6-6-20 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8579 (Japan); Graduate School of Science, Tohoku University, 6-3 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8578 (Japan); Nakamura, Toshio [Center for Chronological Research, Nagoya University, Furo-cho, Chikusa, Nagoya 464-8601 (Japan); Matsunaka, Tetsuya [School of Marine Science and Technology, Tokai University, 3-20-1 Orido, Shimizu, Shizuoka 424-0902 (Japan); Nara, Fumiko Watanabe [Graduate School of Science, Tohoku University, 6-3 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8578 (Japan); Zhu Liping; Wang Junbo [Institute of Tibetan Plateau Research, Chinese Academy of Science, No. 18 Shuangqing Road, Haidian District, Beijing 100085 (China); Kakegawa, Takeshi [Graduate School of Science, Tohoku University, 6-3 Aramaki Aza Aoba, Aoba-ku, Sendai 980-8578 (Japan); Nishimura, Mitsugu [School of Marine Science and Technology, Tokai University, 3-20-1 Orido, Shimizu, Shizuoka 424-0902 (Japan)

    2013-01-15

    Paleoclimatic records from the Tibetan Plateau provide important clues for understanding the Asian monsoon and Asian climate systems. To reconstruct climatic and environmental changes in the southern Tibetan Plateau, a 3.77-m-long sediment core (PY608E-PC) was taken from the southeastern part of Lake Pumoyum Co in August 2006. Because terrestrial plant residues are extremely rare in this core, we performed radiocarbon dating on the total organic carbon fraction. We also estimated the old carbon effect and radiocarbon reservoir age of the total organic carbon fraction. Using these estimates, we propose a new radiocarbon chronology for past climatic changes from ca. 12,500 to 700 cal BP. The linear sedimentation rate of the core was founded to be constant at 32.0 cm/kyr, indicating stable sedimentation conditions in Lake Pumoyum Co from the period of the Younger Dryas to the Holocene.

  8. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    International Nuclear Information System (INIS)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric; Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt; Audouin, Laurent; Tassan-Got, Laurent; Aumann, Thomas; Casarejos, Enrique; Farget, Fanny; Rodriguez-Tajes, Carme; Heinz, Andreas; Jurado, Beatriz; Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut

    2015-01-01

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  9. Studies on fission with ALADIN. Precise and simultaneous measurement of fission yields, total kinetic energy and total prompt neutron multiplicity at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Julie-Fiona; Taieb, Julien; Chatillon, Audrey; Belier, Gilbert; Boutoux, Guillaume; Ebran, Adeline; Gorbinet, Thomas; Grente, Lucie; Laurent, Benoit; Pellereau, Eric [CEA DAM Bruyeres-le-Chatel, Arpajon (France); Alvarez-Pol, Hector; Ayyad, Yassid; Benlliure, Jose; Cortina Gil, Dolores; Caamano, Manuel; Fernandez Dominguez, Beatriz; Paradela, Carlos; Ramos, Diego; Rodriguez-Sanchez, Jose-Luis; Vargas, Jossitt [Universidad de Santiago de Compostela, Santiago de Compostela (Spain); Audouin, Laurent; Tassan-Got, Laurent [CNRS/IN2P3, IPNO, Orsay (France); Aumann, Thomas [Technische Universitaet Darmstadt, Darmstadt (Germany); Casarejos, Enrique [Universidad de Vigo, Vigo (Spain); Farget, Fanny; Rodriguez-Tajes, Carme [CNRS/IN2P3, GANIL, Caen (France); Heinz, Andreas [Chalmers University of Technology, Gothenburg (Sweden); Jurado, Beatriz [CNRS/IN2P3, CENBG, Gradignan (France); Kelic-Heil, Aleksandra; Kurz, Nikolaus; Nociforo, Chiara; Pietri, Stephane; Rossi, Dominic; Schmidt, Karl-Heinz; Simon, Haik; Voss, Bernd; Weick, Helmut [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2015-12-15

    A novel technique for fission studies, based on the inverse kinematics approach, is presented. Following pioneering work in the nineties, the SOFIA Collaboration has designed and built an experimental set-up dedicated to the simultaneous measurement of isotopic yields, total kinetic energies and total prompt neutron multiplicities, by fully identifying both fission fragments in coincidence, for the very first time. This experiment, performed at GSI, permits to study the fission of a wide variety of fissioning systems, ranging from mercury to neptunium, possibly far from the valley of stability. A first experiment, performed in 2012, has provided a large array of unprecedented data regarding the nuclear fission process. An excerpt of the results is presented. With this solid starter, further improvements of the experimental set-up are considered, which are consistent with the expected developments at the GSI facility, in order to measure more fission observables in coincidence. The completeness reached in the SOFIA data, permits to scrutinize the correlations between the interesting features of fission, offering a very detailed insight in this still unraveled mechanism. (orig.)

  10. Tropical forests are a net carbon source based on aboveground measurements of gain and loss

    Science.gov (United States)

    Baccini, A.; Walker, W.; Carvalho, L.; Farina, M.; Sulla-Menashe, D.; Houghton, R. A.

    2017-10-01

    The carbon balance of tropical ecosystems remains uncertain, with top-down atmospheric studies suggesting an overall sink and bottom-up ecological approaches indicating a modest net source. Here we use 12 years (2003 to 2014) of MODIS pantropical satellite data to quantify net annual changes in the aboveground carbon density of tropical woody live vegetation, providing direct, measurement-based evidence that the world’s tropical forests are a net carbon source of 425.2 ± 92.0 teragrams of carbon per year (Tg C year-1). This net release of carbon consists of losses of 861.7 ± 80.2 Tg C year-1 and gains of 436.5 ± 31.0 Tg C year-1. Gains result from forest growth; losses result from deforestation and from reductions in carbon density within standing forests (degradation or disturbance), with the latter accounting for 68.9% of overall losses.

  11. Optoelectronic system of online measurements of unburned carbon in coal fly ash

    Science.gov (United States)

    Golas, Janusz; Jankowski, Henryk; Niewczas, Bogdan; Piechna, Janusz; Skiba, Antoni; Szkutnik, Wojciech; Szkutnik, Zdzislaw P.; Wartak, Ryszarda; Worek, Cezary

    2001-08-01

    Carbon-in-ash level is an important consideration for combustion efficiency as well as ash marketing. The optoelectronic analyzing system for on-line determination and monitoring of the u burned carbon content of ash samples is presented. The apparatus operates on the principle that carbon content is proportional to the reflectance of IR light. Ash samples are collected iso kinetically from the flue gas duct and placed in a sample tube with a flat glass bottom. The same is then exposed to a light. The reflectance intensity is used by the system's computer to determine residual carbon content from correlation curves. The sample is then air purged back to the duct or to the attached sample canister to enable laboratory check analysis. The total cycle time takes between 5 and 10 minutes. Real time result of carbon content with accuracy 0.3-0.7 percent are reported and can be used for boiler controlling.

  12. Measurement of the total solar energy transmittance (g-value) for complex glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1999-01-01

    Four different complex glazings have been investigated in the Danish experimental setup METSET.The purpose of the measurements is to increase the confidence in the calorimetric measurements and to perform measurements and corrections according to a method developed in the ALTSET project...

  13. Research on the Measurement of Carbon Storage in Plantation Tree Trunks Based on the Carbon Storage Dynamic Analysis Method

    Directory of Open Access Journals (Sweden)

    Weida Yin

    2012-01-01

    Full Text Available Estimation of forest carbon storage can be of great significance to the research on the productivity of terrestrial ecosystem, carbon cycle, and global warming. China has more than 54 million hm2 barren hills and waste land suitable for forestation, which provides a great potential for developing carbon sink forestry by means of forestation. This research analyzed the volume increments, volume densities, and carbon contents of 15 analytical samples of five main plantation tree species in North China, including Pinus tabulaeformis (A, Robinia pseudoacacia (B, Populus euramericana (C, Larix olgenisis (D, and Larix kaempferi (E. Results showed that carbon storage dynamic process can be expressed as follows: the ages of quantitative maturity of each tree species are 67a, 40a, 30a, 48a, 49a, respectively; the average wood densities of each tree species at different age classes are 550.93 kg/m3, 629.25 kg/m3, 404.56 kg/m3, 592.33 kg/m3, and 544.11 kg/m3,t. The average carbon contents of each tree species at different age classes are 51.48%, 46.88%, 47.81%, 46.76%, and 47.24%. It showed a significant difference between the above tree species through variance test. The maximum values of average carbon storage are 70a, 40a, 30a, 48.7a, and 49.2a, respectively. The corresponding average carbon storages are A 2.527 kg, B 3,794 kg, C 2.781 kg, D 2.996 kg, and E 3,322 kg, in a descending order of C>E>D>B>A. This research, through experiment on four tree species with clear growth rings and one tree species with unclear growth rings, verified the scientific character and the scope of application of the carbon storage dynamic analysis method, providing a new method for the measurement and analysis of forest carbon storage.

  14. Evaluating measurements of carbon dioxide emissions using a precision source--A natural gas burner.

    Science.gov (United States)

    Bryant, Rodney; Bundy, Matthew; Zong, Ruowen

    2015-07-01

    A natural gas burner has been used as a precise and accurate source for generating large quantities of carbon dioxide (CO2) to evaluate emissions measurements at near-industrial scale. Two methods for determining carbon dioxide emissions from stationary sources are considered here: predicting emissions based on fuel consumption measurements-predicted emissions measurements, and direct measurement of emissions quantities in the flue gas-direct emissions measurements. Uncertainty for the predicted emissions measurement was estimated at less than 1%. Uncertainty estimates for the direct emissions measurement of carbon dioxide were on the order of ±4%. The relative difference between the direct emissions measurements and the predicted emissions measurements was within the range of the measurement uncertainty, therefore demonstrating good agreement. The study demonstrates how independent methods are used to validate source emissions measurements, while also demonstrating how a fire research facility can be used as a precision test-bed to evaluate and improve carbon dioxide emissions measurements from stationary sources. Fossil-fuel-consuming stationary sources such as electric power plants and industrial facilities account for more than half of the CO2 emissions in the United States. Therefore, accurate emissions measurements from these sources are critical for evaluating efforts to reduce greenhouse gas emissions. This study demonstrates how a surrogate for a stationary source, a fire research facility, can be used to evaluate the accuracy of measurements of CO2 emissions.

  15. Investigation of test methods for measuring compressive strength and modulus of two-dimensional carbon-carbon composites

    Science.gov (United States)

    Ohlhorst, Craig W.; Sawyer, James Wayne; Yamaki, Y. Robert

    1989-01-01

    An experimental evaluation has been conducted to ascertain the the usefulness of two techniques for measuring in-plane compressive failure strength and modulus in coated and uncoated carbon-carbon composites. The techniques involved testing specimens with potted ends as well as testing them in a novel clamping fixture; specimen shape, length, gage width, and thickness were the test parameters investigated for both coated and uncoated 0/90 deg and +/-45 deg laminates. It is found that specimen shape does not have a significant effect on the measured compressive properties. The potting of specimen ends results in slightly higher measured compressive strengths than those obtained with the new clamping fixture. Comparable modulus values are obtained by both techniques.

  16. Total variation regularization in measurement and image space for PET reconstruction

    KAUST Repository

    Burger, M

    2014-09-18

    © 2014 IOP Publishing Ltd. The aim of this paper is to test and analyse a novel technique for image reconstruction in positron emission tomography, which is based on (total variation) regularization on both the image space and the projection space. We formulate our variational problem considering both total variation penalty terms on the image and on an idealized sinogram to be reconstructed from a given Poisson distributed noisy sinogram. We prove existence, uniqueness and stability results for the proposed model and provide some analytical insight into the structures favoured by joint regularization. For the numerical solution of the corresponding discretized problem we employ the split Bregman algorithm and extensively test the approach in comparison to standard total variation regularization on the image. The numerical results show that an additional penalty on the sinogram performs better on reconstructing images with thin structures.

  17. Using value-based total cost of ownership (TCO) measures to inform subsystem trade-offs

    Science.gov (United States)

    Radziwill, Nicole M.; DuPlain, Ronald F.

    2010-07-01

    Total Cost of Ownership (TCO) is a metric from management accounting that helps expose both the direct and indirect costs of a business decision. However, TCO can sometimes be too simplistic for "make vs. buy" decisions (or even choosing between competing design alternatives) when value and extensibility are more critical than total cost. A three-dimensional value-based TCO, which was developed to clarify product decisions for an observatory prior to Final Design Review (FDR), will be presented in this session. This value-based approach incorporates priority of requirements, satisfiability of requirements, and cost, and can be easily applied in any environment.

  18. Is Time the Best Metric to Measure Carbon-Related Climate Change Potential and Tune the Economy Toward Reduced Fossil Carbon Extraction?

    Science.gov (United States)

    DeGroff, F. A.

    2016-12-01

    Anthropogenic changes to non-anthropogenic carbon fluxes are a primary driver of climate change. There currently exists no comprehensive metric to measure and value anthropogenic changes in carbon flux between all states of carbon. Focusing on atmospheric carbon emissions as a measure of anthropogenic activity on the environment ignores the fungible characteristics of carbon that are crucial in both the biosphere and the worldwide economy. Focusing on a single form of inorganic carbon as a proxy metric for the plethora of anthropogenic activity and carbon compounds will prove inadequate, convoluted, and unmanageable. A broader, more basic metric is needed to capture the entirety of carbon activity, particularly in an economic, profit-driven environment. We propose a new metric to measure changes in the temporal distance of any form or state of carbon from one state to another. Such a metric would be especially useful to measure the temporal distance of carbon from sinks such as the atmosphere or oceans. The effect of changes in carbon flux as a result of any human activity can be measured by the difference between the anthropogenic and non-anthropogenic temporal distance. The change in the temporal distance is a measure of the climate change potential much like voltage is a measure of electrical potential. The integral of the climate change potential is proportional to the anthropogenic climate change. We also propose a logarithmic vector scale for carbon quality, cq, as a measure of anthropogenic changes in carbon flux. The distance between the cq vector starting and ending temporal distances represents the change in cq. A base-10 logarithmic scale would allow the addition and subtraction of exponents to calculate changes in cq. As anthropogenic activity changes the temporal distance of carbon, the change in cq is measured as: cq = ß ( log10 [mean carbon temporal distance] ) where ß represents the carbon price coefficient for a particular country. For any

  19. VARIABILITY OF FORCED OSCILLATION (SIEMENS SIREGNOST FD-5) MEASUREMENTS OF TOTAL RESPIRATORY RESISTANCE IN PATIENTS AND HEALTHY-SUBJECTS

    NARCIS (Netherlands)

    GIMENO, F; VANDERWEELE, LT; KOETER, GH; DEMONCHY, JGR; VANALTENA, R

    The reproducibility of total respiratory resistance (R(rs)) measured with a simplified forced oscillatory method (Siemens Siregnost FD 5) was measured and compared with that of slow inspiratory vital capacity (IVC) and forced expiratory volume in one second (FEV1). The former technique has the

  20. Measure a carbon impact methodology in line with a 2 degree scenario

    International Nuclear Information System (INIS)

    Coeslier, Manuel; Finidori, Esther; Smia, Ladislas

    2015-11-01

    Today, high expectations surround the measurement of carbon impact. Voluntary initiatives and - little by little - legislation push institutional investors to consider the impact that financial portfolios have on the climate and energy transition. However, current methods (of carbon footprint measurement) are not adequate to determine an investment portfolio's contribution to these issues. Current approaches, which do not take a life-cycle vision of carbon foot-printing, have the particular flaw of not accounting for emissions related to companies' products and services. The impact of these products and services on the climate is, however, crucial in many sectors - whether positively in the case of renewable energy and energy efficiency solutions, or negatively in the case of fossil fuels. Following this observation, Mirova and Carbone 4 decided to create a partnership dedicated to developing a new methodology capable of providing a carbon measurement that is aligned with the issues of energy transition: Carbon Impact Analytics (CIA). The CIA methodology focuses primarily on three indicators: - A measure of emissions 'induced' by a company's activity from a life-cycle approach, taking into account direct emissions as well as emissions from product suppliers; - A measure of the emissions which are 'avoided' due to efficiency efforts or deployment of 'low-carbon' solutions; - An overall evaluation that takes into account, in addition to carbon measurement, further information on the company's evolution and the type of capital or R and D expenditures. For these evaluations, the methodology employs a bottom-up approach in which each company is examined individually according to an evaluation framework adapted to each sector. Particular scrutiny is devoted to companies with a significant climate impact: energy producers, carbon-intensive sectors (industry, construction, transport), and providers of low-carbon equipment and solutions. Evaluations are then aggregated at

  1. Airborne Measurements in Support of the NASA Atmospheric Carbon and Transport - America (ACT-America) Mission

    Science.gov (United States)

    Meadows, Byron; Davis, Ken; Barrick, John; Browell, Edward; Chen, Gao; Dobler, Jeremy; Fried, Alan; Lauvaux, Thomas; Lin, Bing; McGill, Matt; hide

    2015-01-01

    NASA announced the research opportunity Earth Venture Suborbital -2 (EVS-2) mission in support of the NASA's science strategic goals and objectives in 2013. Penn State University, NASA Langley Research Center (LaRC), and other academic institutions, government agencies, and industrial companies together formulated and proposed the Atmospheric Carbon and Transport -America (ACT -America) suborbital mission, which was subsequently selected for implementation. The airborne measurements that are part of ACT-America will provide a unique set of remote and in-situ measurements of CO2 over North America at spatial and temporal scales not previously available to the science community and this will greatly enhance our understanding of the carbon cycle. ACT -America will consist of five airborne campaigns, covering all four seasons, to measure regional atmospheric carbon distributions and to evaluate the accuracy of atmospheric transport models used to assess carbon sinks and sources under fair and stormy weather conditions. This coordinated mission will measure atmospheric carbon in the three most important regions of the continental US carbon balance: Northeast, Midwest, and South. Data will be collected using 2 airborne platforms (NASA Wallops' C-130 and NASA Langley's B-200) with both in-situ and lidar instruments, along with instrumented ground towers and under flights of the Orbiting Carbon Observatory (OCO-2) satellite. This presentation provides an overview of the ACT-America instruments, with particular emphasis on the airborne CO2and backscatter lidars, and the, rationale, approach, and anticipated results from this mission.

  2. Comparative responsiveness of measures of pain and function after total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A K; Roos, Ewa M.; Westerlund, J P

    2001-01-01

    To compare the responsiveness of the Functional Assessment System (FAS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Medical Outcomes Study 36-item Short Form (SF-36) in patients with osteoarthritis (OA) scheduled for total hip replacement....

  3. Measurement of total angular momentum values of high-lying even ...

    Indian Academy of Sciences (India)

    Spectrally resolved laser-induced fluorescence technique was used to uniquely assign total angular momentum () values to high-lying even-parity energy levels of atomic samarium. Unique value assignment was done for seven energy levels in the energy region 34,800–36,200 cm-1 , recently observed and reported in ...

  4. Measurements methods and variability assesment of the Norway spruce total leaf area. Implications for remote sensing

    Czech Academy of Sciences Publication Activity Database

    Homolová, L.; Lukeš, Petr; Malenovský, Z.; Lhotáková, Z.; Kaplan, Věroslav; Hanuš, Jan

    2013-01-01

    Roč. 27, č. 1 (2013), s. 111-121 ISSN 0931-1890 R&D Projects: GA ČR GA205/09/ 1989 Institutional support: RVO:67179843 Keywords : chlorophyll content * conversion factor * Picea abies * projected leaf area * remote sensing * total leaf area Subject RIV: EH - Ecology, Behaviour Impact factor: 1.869, year: 2013

  5. Non-destructive Measurement of Total Carotenoid Content in Processed Tomato Products

    NARCIS (Netherlands)

    Bicanic, D.; Streza, M.; Dóka, O.; Valinger, D.; Luterotti, S.; Ajtony, Zs; Kurtanjek, Z.; Dadarlat, D.

    2015-01-01

    Carotenes found in a diversity of fruits and vegetables are among important natural antioxidants. In a study described in this paper, the total carotenoid content (TCC) in seven different products derived from thermally processed tomatoes was determined using laser photoacoustic spectroscopy

  6. Relationship between Improvements in Physical Measures and Patient Satisfaction in Rehabilitation after Total Knee Arthroplasty

    Science.gov (United States)

    Nazzal, Mahmoud I.; Bashaireh, Khaldoon H.; Alomari, Mahmoud A.; Nazzal, Mohammad S.; Maayah, Mikhled F.; Mesmar, Mohammad

    2012-01-01

    The aim of this study was to examine patient satisfaction with rehabilitation after total knee arthroplasty (TKA). Fifty-six patients, aged 45-77 years, were enrolled in a post-TKA comprehensive therapy program focusing on knee strengthening and functional activities. The program lasted 3 months and was conducted for 1 h, twice a day, 5 days per…

  7. Error analysis of Dobson spectrophotometer measurements of the total ozone content

    Science.gov (United States)

    Holland, A. C.; Thomas, R. W. L.

    1975-01-01

    A study of techniques for measuring atmospheric ozone is reported. This study represents the second phase of a program designed to improve techniques for the measurement of atmospheric ozone. This phase of the program studied the sensitivity of Dobson direct sun measurements and the ozone amounts inferred from those measurements to variation in the atmospheric temperature profile. The study used the plane - parallel Monte-Carlo model developed and tested under the initial phase of this program, and a series of standard model atmospheres.

  8. Preoperative Measurement of Tibial Resection in Total Knee Arthroplasty Improves Accuracy of Postoperative Limb Alignment Restoration

    Directory of Open Access Journals (Sweden)

    Pei-Hui Wu

    2016-01-01

    Conclusions: Using conventional surgical instruments, preoperative measurement of resection thickness of the tibial plateau on radiographs could improve the accuracy of conventional surgical techniques.

  9. Global Electric Circuit Implications of Total Current Measurements over Electrified Clouds

    Science.gov (United States)

    Mach, Douglas M.; Blakeslee, Richard J.; Bateman, Monte G.

    2009-01-01

    We determined total conduction (Wilson) currents and flash rates for 850 overflights of electrified clouds spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, with and without lightning, and with positive and negative Wilson currents. We combined these individual storm overflight statistics with global diurnal lightning variation data from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) to estimate the thunderstorm and electrified shower cloud contributions to the diurnal variation in the global electric circuit. The contributions to the global electric circuit from lightning producing clouds are estimated by taking the mean current per flash derived from the overflight data for land and ocean overflights and combining it with the global lightning rates (for land and ocean) and their diurnal variation derived from the LIS/OTD data. We estimate the contribution of non-lightning producing electrified clouds by assuming several different diurnal variations and total non-electrified storm counts to produce estimates of the total storm currents (lightning and non-lightning producing storms). The storm counts and diurnal variations are constrained so that the resultant total current diurnal variation equals the diurnal variation in the fair weather electric field (+/-15%). These assumptions, combined with the airborne and satellite data, suggest that the total mean current in the global electric circuit ranges from 2.0 to 2.7 kA, which is greater than estimates made by others using other methods.

  10. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  11. Model-based wear measurements in total knee arthroplasty : development and validation of novel radiographic techniques

    NARCIS (Netherlands)

    IJsseldijk, van E.A.

    2016-01-01

    The primary aim of this work was to develop novel model-based mJSW measurement methods using a 3D reconstruction and compare the accuracy and precision of these methods to conventional mJSW measurement. This thesis contributed to the development, validation and clinical application of model-based

  12. Some measurements of total electron content made with the ATS-6 radio beacon

    International Nuclear Information System (INIS)

    Davies, K.; Degenhardt, W.; Hartmann, G.K.

    1978-01-01

    The paper deals with some measurements made with the radio beacon on board the ATS-6 satellite in the American and European sectors. Measurements of the slant electron content, the Faraday content, and the plasmaspheric (or residual) content, made under different geographic and geomagnetic conditions, are discussed and compared

  13. Localized hippocampus measures are associated with Alzheimer pathology and cognition independent of total hippocampal volume.

    NARCIS (Netherlands)

    Carmichael, O.; Xie, J.; Fletcher, E.; Singh, B.; DeCarli, C.; Olde Rikkert, M.; et al.,

    2012-01-01

    Hippocampal injury in the Alzheimer's disease (AD) pathological process is region-specific and magnetic resonance imaging (MRI)-based measures of localized hippocampus (HP) atrophy are known to detect region-specific changes associated with clinical AD, but it is unclear whether these measures

  14. Localized hippocampus measures are associated with Alzheimer pathology and cognition independent of total hippocampal volume

    NARCIS (Netherlands)

    Carmichael, Owen; Xie, Jing; Fletcher, Evan; Singh, Baljeet; Decarli, Charles; A, Saradha; Abdi, Hervé; Abdul Hadi, Normi; Abdulkadir, Ahmed; Abdullah, Afnizanfaizal; Achuthan, Anusha; Adluru, Nagesh; Aggarwal, Namita; Aghajanian, Jania; Agyemang, Alex; Ahdidan, Jamila; Ahmad, Duaa; Ahmed, Shiek; Ahmed, Fareed; Ahmed, Fayeza; Akbarifar, Roshanak; Akhondi-Asl, Alireza; Aksu, Yaman; Alcauter, Sarael; Daniel, Alexander; Alin, Aylin; Alshuft, Hamza; Alvarez-Linera, Juan; Amin-Mansour, Ali; Anderson, Dallas; Anderson, Jeff; Andorn, Anne; Ang, Amma; Angersbach, Steve; Ansarian, Reza; Appaji, Abhishek; Appannah, Arti; Arfanakis, Konstantinos; Armentrout, Steven; Arrighi, Michael; Arumughababu, S. Vethanayaki; Arunagiri, Vidhya; Ashe-McNalley, Cody; Ashford, Wes; Aurelie, Le Page; Avants, Brian; Aviv, Richard; Avula, Ramesh; Richard, Edo; Schmand, Ben

    2012-01-01

    Hippocampal injury in the Alzheimer's disease (AD) pathological process is region-specific and magnetic resonance imaging (MRI)-based measures of localized hippocampus (HP) atrophy are known to detect region-specific changes associated with clinical AD, but it is unclear whether these measures

  15. Total Measurement Uncertainty (TMU) for Nondestructive Assay of Transuranic (TRU) Waste at the WRAP Facility

    International Nuclear Information System (INIS)

    WILLS, C.E.

    1999-01-01

    This report examines the contributing factors to NDA measurement uncertainty at WRAP. The significance of each factor on the TMU is analyzed, and a final method is given for determining the TMU for NDA measurements at WRAP. As more data becomes available, and WRAP gains in operational experience, this report will be reviewed semi-annually and updated as necessary

  16. Precise Measurement of the $\\bar{p}p$ Total Cross-Section in the ISR Energy Range

    CERN Multimedia

    2002-01-01

    The major aim of this experiment is the precise measurement of the antiproton-proton total cross-section in the ISR energy range, using the total-rate method. The proton-proton total cross-section is remeasured with the same method and the same apparatus, and a precision of 0.5\\% is expected for both cross-sections. The total-rate method consists in the simultaneous measurement of the total interaction rate and the ISR luminosity. This is done with a set of scintillation-counter hodoscopes covering over 99.99\\% of the solid angle, which are sensitive to over 95\\% of all interactions. In addition to these detectors, small-angle drift-tube hodoscopes are used to measure the differential elastic cross-section as a function of the momentum transfert t. The total cross-section can be measured independently by extrapolating this differential cross-section to the forward direction and invoking the optical theorem. A study of the general features of charged-particle production is performed using finely divided scinti...

  17. Measurement of parity nonconservation in the proton-proton total cross section at 800 MeV

    International Nuclear Information System (INIS)

    Bowman, J.D.

    1986-01-01

    A report is made of a measurement of parity nonconservation in the transmission of 800-MeV longitudinally polarized protons through an unpolarized, 1-m liquid-hydrogen target. The dependence of transmission on beam properties was studied to measure and to correct for systematic errors. The measured longitudinal asymmetry in the total cross section is A/sub L/ = [+2.4 +- 1.1 (statistical) +- 0.1 (systematic)] x 10 -7 . 25 refs., 2 figs

  18. Carbon dioxide titration method for soil respiration measurements

    OpenAIRE

    Martín Rubio, Luis

    2017-01-01

    This thesis was commissioned by Tampere University of Applied Sciences, which was interested in studying and developing a titration measurement method for soil respiration and biodegradability. Some experiments were carried out measuring soil respiration for testing the method and others adding some biodegradable material like polylactic acid compressed material and 100% biodegradable plastic bags to test its biodegradability and the possibility to measure it via titration. The thesi...

  19. Changes in soil organic carbon and total nitrogen in croplands converted to walnut-based agroforestry systems and orchards in southeastern Loess Plateau of China.

    Science.gov (United States)

    Lu, Sen; Meng, Ping; Zhang, Jinsong; Yin, Changjun; Sun, Shiyou

    2015-11-01

    Limited information is available on the effects of agroforestry system practices on soil properties in the Loess Plateau of China. Over the last decade, a vegetation restoration project has been conducted in this area by converting cropland into tree-based agroforestry systems and orchards to combat soil erosion and degradation. The objective of the present study was to determine the effects of land use conversion on soil organic carbon and total nitrogen in southeastern Loess Plateau. The experiment included three treatments: walnut intercropping system (AF), walnut orchard (WO), and traditional cropland (CR). After 7 years of continual management, soil samples were collected at 0-10, 10-30, and 30-50-cm depths for three treatments, and soil organic carbon (SOC) and total nitrogen (TN) were measured. Results showed that compared with the CR and AF treatments, WO treatment decreased both SOC and TN concentrations in the 0-50-cm soil profile. However, similar patterns of SOC and TN concentrations were observed in the AF and CR treatments across the entire profile. The SOC stocks at 0-50-cm depth were 5.42, 5.52, and 4.67 kg m(-2) for CR, AF, and WO treatments, respectively. The calculated TN stocks at 0-50-cm depth were 0.63, 0.62, and 0.57 kg m(-2) for CR, AF, and WO treatments, respectively. This result demonstrated that the stocks of SOC and TN in WO were clearly lower than those of AF and CR and that the walnut-based agroforestry system was more beneficial than walnut monoculture in terms of SOC and TN sequestration. Owing to the short-term intercropping practice, the changes in SOC and TN stocks were slight in AF compared with those in CR. However, a significant decrease in SOC and TN stocks was observed during the conversion of cropland to walnut orchard after 7 years of management. We also found that land use types had no significant effect on soil C/N ratio. These findings demonstrated that intercropping between walnut rows can potentially maintain

  20. Laser ablation-laser induced breakdown spectroscopy for the measurement of total elemental concentration in soils.

    Science.gov (United States)

    Pareja, Jhon; López, Sebastian; Jaramillo, Daniel; Hahn, David W; Molina, Alejandro

    2013-04-10

    The performances of traditional laser-induced breakdown spectroscopy (LIBS) and laser ablation-LIBS (LA-LIBS) were compared by quantifying the total elemental concentration of potassium in highly heterogeneous solid samples, namely soils. Calibration curves for a set of fifteen samples with a wide range of potassium concentrations were generated. The LA-LIBS approach produced a superior linear response different than the traditional LIBS scheme. The analytical response of LA-LIBS was tested with a large set of different soil samples for the quantification of the total concentration of Fe, Mn, Mg, Ca, Na, and K. Results showed an acceptable linear response for Ca, Fe, Mg, and K while poor signal responses were found for Na and Mn. Signs of remaining matrix effects for the LA-LIBS approach in the case of soil analysis were found and discussed. Finally, some improvements and possibilities for future studies toward quantitative soil analysis with the LA-LIBS technique are suggested.