WorldWideScience

Sample records for total bolus injection

  1. Characterization of an intravenously injected bolus

    International Nuclear Information System (INIS)

    Samuel, A.M.; Raikar, U.R.; Atmaram, S.H.; Ganatra, R.D.

    1976-01-01

    A study of some parameters affecting the time activity histogram of an intravenous bolus injection of radioactivity was performed. A scoring system for bolus compactness was attempted. A score of 2 and above was considered to be a satisfactory bolus. Volumes less than 1 ml tended to result in a satisfactory bolus. The nature of radiopharmaceutical injected, different injecters and age of the patient did not affect the score. Thyrotoxic patients gave the best bolus score. (orig.) [de

  2. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  3. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    International Nuclear Information System (INIS)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto

    1996-01-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  4. Assessment of injection bolus in first-pass radionuclide angiography. Evaluation of injection site and needle size

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, Syuichi; Inagaki, Syoichi; Yasui, Masakazu; Sugishita, Kouki; Yoshita, Hisashi; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1996-09-01

    First-pass radionuclide angiography (FPRNA) using a multi-crystal gamma camera can correctly provide many quantitative and qualitative indices of left ventricular function as well as anatomic information. A compact injection bolus of radiotracer is, however, essential to the first-pass study since the temporal separation of cardiac chambers is required for the first-pass acquisition. To examine which factors affect the quality of an injection bolus, 327 patients who had FPRNA in the anterior projection were randomized for injection site of radiotracer (right or left external jugular veins, and right antecubital vein) and needle size (19- or 21-gauge). The injected bolus was assessed from the full width at half maximum (FWHM) of the bolus time-activity curve in the superior vena cava. As to injection site using a 19-gauge needle, an attemption through right external jugular vein (EJV) revealed the shortest FWHM of an injection bolus, followed by left EJV and right antecubital vein (AV). In right EJV 91% of injected bolus FWHM was less than 1.5 sec, which was significantly higher (p<0.001) than those of the other sites (left EJV: 70%. right AV: 65%). Approximately 7% of injection from left EJV and right AV, showed a split bolus of radiotracer. However, no split bolus was observed from right EJV. There was no significant difference in FWHM of an injection bolus between 19- and 21-gauge needle from EJV. Our present study demonstrated that the quality of an injection bolus from left EJV and AV was affected by RVEF in a case of low right ventricular function. In conclusion, right EJV is the first choice of injection site to obtain a compact bolus of radiotracer for the first-pass cardiac study. A 21-gauge needle can also be inserted from the external jugular vein to perform a good bolus injection. (author)

  5. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  6. Dynamic computed tomography after bolus injection and infusion of perfluorooctylbromide (PFOB)

    International Nuclear Information System (INIS)

    Adam, G.; Guenther, R.W.; Goertz, H.; Schiffer, C.

    1992-01-01

    We investigated the enhancement of the liver, the spleen, and of induced abscesses and the abdominal vessels after administration of 3 g/kg bodyweight Perfluoroocytlbromide (PFOB) on an animal model. Twenty-one rabbits each received the contrast medium as bolus injection and as slow infusion over half an hour. CT was performed between 2 and 48 hours after contrast medium application. Peak enhancement of the liver, the spleen and the liver abscess membrane was found between 24 and 48 hours after PFOB administration, independently of the application mode. Peak enhancement of the abdominal aorta and the IVC was observed within two hours after bolus injection. In this rabbit model PFOB permits best delineation of the vessels after bolus injection within the first two hours, while CT imaging of the liver, the spleen and the liver abscess membrane is best between 24 and 48 hours after contrast medium application, independent of the injection velocity. (orig.) [de

  7. Perception of Diabetic Patients Regarding Basal Bolus Insulin Injections and Outcome of its Use

    International Nuclear Information System (INIS)

    Shahid, M.; Sarfraz, A.; Mahar, S. A.; Alam, M.; Shaikh, S.; Shahid, N.

    2016-01-01

    Objective: To assess the perceptions regarding basal bolus insulin injections and the changes in blood glucose levels and glycosylated hemoglobin (HbA1c) before and after 3 months of such treatment in diabetic patients. Study Design: Quasi-experimental study. Place and Duration of Study: Department of Endocrinology, Liaquat National Hospital, Karachi, from December 2014 to March 2015. Methodology: A total of 222 diabetic patients started on basal bolus insulin injection were enrolled and asked to answer 17 questions. Those with complications of diabetes were excluded. Fasting blood glucose (FBS), random blood glucose (RBS) and HbA1c levels were checked initially, and after 3 months of getting basal bolus insulin. Paired t-test and chi-square test were used for determining p-value with significance at p < 0.05. Results: Majority (n=217, 97.7 percentage) of the patients were previously taking other insulins. Before starting this treatment, the mean FBS was 260.5 ± 52.2 mg/dl, RBS was 385.5 percentage 47.61 mg/dl and HbA1c was 12.76 percentage 1.92 percentage. After 3 months of treatment, FBS improved to 117.9 ± 14.2 mg/dl, RBS was 156.7 ± 17.09 mg/dl and HbA1c was 7.72 ± 4.41 percentage (p < 0.001). Two hundred and sixteen (97.3 percentage) patients believed that basal bolus insulin was started as their diabetes worsened; 15 (70.70 percentage) thought that their blood glucose control would improve with the use of this form of insulin. One hundred and ninety four (87.4 percentage) had fear of needle injections. Perceptions regarding hypoglycemia with this form of insulin were observed in 157 (70.7 percentage). One hundred and twenty seven (84.1 percentage) of the females and 51 (71.8 percentage) of the males thought that the basal bolus insulin regimen was too expensive (p=0.032). Conclusion: There were many misconceptions in patients who were started on basal bolus insulin. Marked improvement in blood glucose levels and HbA1c were observed after the use of this

  8. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial.

    Science.gov (United States)

    Mungroop, Timothy H; van Samkar, Ganapathy; Geerts, Bart F; van Dieren, Susan; Besselink, Marc G; Veelo, Denise P; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine at the start of laparotomy, similar to the bolus given with epidural analgesia. This was a comparative study within a randomized controlled trial (NTR4948). Patients undergoing hepato-pancreato-biliary surgery received either a pre-peritoneal bolus of 30ml bupivacaine 0.25%, or an epidural bolus of 10ml bupivacaine 0.25% at the start of laparotomy. In a subgroup of patients, we sampled blood and determined bupivacaine serum levels 20, 40, 60 and 80 minutes after bolus injection. We assumed toxicity of bupivacaine to be >1000 ng/ml. A total of 20 patients participated in this sub-study. All plasma levels measured as well as the upper limit of the predicted 99% confidence intervals per time point were well below the toxicity limit. In a mixed linear-effect model both groups did not differ statistically significant (p = 0.131). The intra-operative use of opioids was higher with CWI as compared to epidural (86 (SD 73) μg sufentanil vs. 50 (SD 32). In this exploratory study, the pre-peritoneal bolus using bupivacaine resulted in serum bupivacaine concentrations well below the commonly accepted toxic threshold. With CWI more additional analgesics are needed intraoperatively as compared to epidural analgesia, although this is compensated by a reduction in use of vasopressors with CWI. Netherlands Trial Register NTR4948.

  9. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance

    Directory of Open Access Journals (Sweden)

    Alfakih Khaled

    2011-05-01

    Full Text Available Abstract Background The dual-bolus protocol enables accurate quantification of myocardial blood flow (MBF by first-pass perfusion cardiovascular magnetic resonance (CMR. However, despite the advantages and increasing demand for the dual-bolus method for accurate quantification of MBF, thus far, it has not been widely used in the field of quantitative perfusion CMR. The main reasons for this are that the setup for the dual-bolus method is complex and requires a state-of-the-art injector and there is also a lack of post processing software. As a solution to one of these problems, we have devised a universal dual-bolus injection scheme for use in a clinical setting. The purpose of this study is to show the setup and feasibility of the universal dual-bolus injection scheme. Methods The universal dual-bolus injection scheme was tested using multiple combinations of different contrast agents, contrast agent dose, power injectors, perfusion sequences, and CMR scanners. This included 3 different contrast agents (Gd-DO3A-butrol, Gd-DTPA and Gd-DOTA, 4 different doses (0.025 mmol/kg, 0.05 mmol/kg, 0.075 mmol/kg and 0.1 mmol/kg, 2 different types of injectors (with and without "pause" function, 5 different sequences (turbo field echo (TFE, balanced TFE, k-space and time (k-t accelerated TFE, k-t accelerated balanced TFE, turbo fast low-angle shot and 3 different CMR scanners from 2 different manufacturers. The relation between the time width of dilute contrast agent bolus curve and cardiac output was obtained to determine the optimal predefined pause duration between dilute and neat contrast agent injection. Results 161 dual-bolus perfusion scans were performed. Three non-injector-related technical errors were observed (1.9%. No injector-related errors were observed. The dual-bolus scheme worked well in all the combinations of parameters if the optimal predefined pause was used. Linear regression analysis showed that the optimal duration for the predefined

  10. Normal mediastinal and hilar lymph nodes evaluated by 5 mm slice bolus injection CT scan

    International Nuclear Information System (INIS)

    Yamamoto, Takako; Tsukada, Hiroshi; Koizumi, Naoya; Akita, Shinichi; Oda, Junichi; Sakai, Kunio

    1995-01-01

    We evaluated the number and size of normal mediastinal and hilar lymph nodes by 5 mm slice bolus injection CT (12 patients), compared with 10 mm slice CT (12 patients). More lymph nodes were clearly demonstrated by 5 mm slice CT than by 10 mm slice CT. Especially left-sided tracheobronchial (no.4), subaortic (no.5), subcarinal (no.7) and hilar lymph nodes were clearly visible. We concluded 5 mm slice bolus injection CT was useful to evaluate mediastinal and hilar lymph nodes. (author)

  11. Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    Science.gov (United States)

    Tsuboyama, Takahiro; Jost, Gregor; Pietsch, Hubertus; Tomiyama, Noriyuki

    2017-09-01

    The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-tracking technique, and thoracic-abdominal time-resolved 4-dimensional [4D] MRA) were performed after power and manual injection of gadobutrol (0.1 mmol/kg) at 2 mL/s in 12 pigs (6 sets of power and manual injections for each type of CE-MRA). For the quantitative analysis, the signal-to-noise ratio was measured on ascending aorta, descending aorta, brachiocephalic trunk, common carotid artery, and external carotid artery on the 6 sets of head-neck 3D MRA, and on ascending aorta, descending aorta, brachiocephalic trunk, abdominal aorta, celiac trunk, and renal artery on the 6 sets of thoracic-abdominal 3D MRA. Bolus shapes were evaluated on the 6 sets each of test-bolus scans and 4D MRA. For the qualitative analysis, arterial enhancement, superimposition of nontargeted enhancement, and overall image quality were evaluated on 3D MRA. Visibility of bolus transition was assessed on 4D MRA. Intraindividual comparison between power and manual injection was made by paired t test, Wilcoxon rank sum test, and analysis of variance by ranks. Signal-to-noise ratio on 3D MRA was statistically higher with power injection than with manual injection (P < 0.001). Bolus shapes (test-bolus, 4D MRA) were represented by a characteristic standard bolus curve (sharp first-pass peak followed by a gentle recirculation peak) in all the 12 scans with power injection, but only in 1 of the 12 scans with manual injection. Standard deviations of time-to-peak enhancement were smaller in power injection than in manual injection. Qualitatively, although both injection methods achieved diagnostic quality on 3D MRA, power injection exhibited significantly higher image quality than manual injection (P = 0.001) due to

  12. Study of the usefulness on liver CT using intermittent bolus injection method

    International Nuclear Information System (INIS)

    Hayashi, Hideo

    1990-01-01

    Usefulness on the liver CT using intermittent bolus injection method of contrast media (IM-CE) was studied in 108 hepatic space occupying lesions, particularly to analyze hepatocellular carcinoma (HCC). Scans were obtained before, 20∼30 (arterial phase) and 60 seconds (parenchymal phase) after intravenous bolus injection of 65%-diatrizoate (angiografin) or 300 mg I-iopamidol (iopamiron 300), and in case of necessity, added 3∼15 minutes (late phase) after all injections of contrast media. These scans imaging the features of hepatic mass provided us much useful information. Early enhancement of the arterial phase, and early wash out of the parenchymal phase and delayed ring enhancement of the capsule improved the rates of detection to 96%, 60%, and 49% respectively in case of HCC. Especially. at the small HCC (less than 2cm in diameter), these rates were 89%, 50%, and 28% respectively. Combination of these 3 findings suggested the possibility of HCC in comparison with other hepatic mass. The rate of accurate diagnosis of HCC by this IM-CE was 81%. Thus IM-CE CT provides the useful information in diagnosis of hepatic mass and should be considered as the routine examination of hepatic mass. (author)

  13. Review of adverse reactions, including anaphylaxis, in 4,260 intravenous bolus injections

    International Nuclear Information System (INIS)

    Kanal, E.; Applegate, G.R.; Gillen, C.P.

    1990-01-01

    This paper evaluates the incidence and type of adverse reactions to Gd-DTPA (Magnevist) after bolus administration in an active clinical MR setting. Between May 1988 and March 1990, 4,260 bolus intravenous injections of Gd-DTPA, 0.1 mmol/kg, were administered during clinical MR examinations. Patient tolerance and reactions were recorded in each instance. All cases of suspected local infiltration were excluded from this study. Review of this data revealed 15 instances of nausea and 12 of emesis following contrast administration. In addition, there were five or fewer cases of associated headaches, dizziness, odd tastes, seizures (with prior seizure histories) mild chest pain, palpitations, hives, or wheezing

  14. Feasibility of power contrast injections and bolus triggering during CT scans in oncologic patients with totally implantable venous access ports of the forearm

    International Nuclear Information System (INIS)

    Goltz, Jan Peter; Machann, Wolfram; Noack, Claudia; Hahn, Dietbert; Kickuth, Ralph

    2011-01-01

    Background: Conventional totally implantable venous access ports (TIVAPs) are not approved for power contrast injections but often remain the only venous access site in oncologic patients. Therefore, these devices can play an important role if patients with a TIVAP are scheduled for a contrast-enhanced computed tomography (ceCT) as vascular access may become more difficult during the course of chemotherapy. Purpose: To evaluate the feasibility and safety of power injections in conventional TIVAPs in the forearm and to analyze the feasibility of bolus triggering during CT scans. Material and Methods: In this retrospective study we analyzed 177 power injections in 141 patients with TIVAPs in the forearm. Between October 2008 and March 2010 all patients underwent power injections (1.5 mL/s, 150 psi) via the TIVAP for ceCT because conventional vascular access via a peripheral vein had failed. Adequate functioning and catheter's tip location after injection were evaluated. Peak injection pressure and attenuation levels of aorta, liver and spleen were analyzed and compared with results of 50 patients who were injected via classical peripheral cannulas (3 mL/s, 300 psi). Feasibility of automatic scan initiation was evaluated. In vitro the port was stressed with 5 mL/s (300 psi). Results: One TIVAP showed tip dislocation with catheter rupture. Three (2.1%) devices were explanted owing to assumed infection within 4 weeks after the injection. Mean injection pressure was 121.9 ±24.1 psi. Triggering with automatic scan initiation succeeded in 13/44 (29.6%) scans. Injection via classical cannulas resulted in significantly higher enhancement (p < 0.05). In vitro the port system tolerated flow rates of up to 5 mL/s, injection pressures of up to 338 psi. Conclusion: Power injection is a safe alternative for patients with TIVAPs in the forearm if classic vascular access ultimately fails. Triggering was successful in one-third of the attempts. Image quality in the arterial phase

  15. Ultrasound-mediated gene delivery of naked plasmid DNA in skeletal muscles: a case for bolus injections.

    Science.gov (United States)

    Sanches, Pedro Gomes; Mühlmeister, Mareike; Seip, Ralf; Kaijzel, Eric; Löwik, Clemens; Böhmer, Marcel; Tiemann, Klaus; Grüll, Holger

    2014-12-10

    Localized gene delivery has many potential clinical applications. However, the nucleic acids (e.g. pDNA and siRNA) are incapable of passively crossing the endothelium, cell membranes and other biological barriers which must be crossed to reach their intracellular targets. A possible solution is the use of ultrasound to burst circulating microbubbles inducing transient permeabilization of surrounding tissues which mediates nucleic acid extravasation and cellular uptake. In this study we report on an optimization of the ultrasound gene delivery technique. Naked pDNA (200 μg) encoding luciferase and SonoVue® microbubbles were co-injected intravenously in mice. The hindlimb skeletal muscles were exposed to ultrasound from a non-focused transducer (1 MHz, 1.25 MPa, PRI 30s) and injection protocols and total amounts as well as ultrasound parameters were systemically varied. Gene expression was quantified relative to a control using a bioluminescence camera system at day 7 after sonication. Bioluminescence ratios in sonicated/control muscles of up to 101× were obtained. In conclusion, we were able to specifically deliver genetic material to the selected skeletal muscles and overall, the use of bolus injections and high microbubble numbers resulted in increased gene expression reflected by stronger bioluminescence signals. Based on our data, bolus injections seem to be required in order to achieve transient highly concentrated levels of nucleic acids and microbubbles at the tissue of interest which upon ultrasound exposure should lead to increased levels of gene delivery. Thus, ultrasound mediated gene delivery is a promising technique for the clinical translation of localized drug delivery. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Evaluation of reconstruction parameters of electrical impedance tomography on aorta detection during saline bolus injection

    Directory of Open Access Journals (Sweden)

    Thürk Florian

    2016-09-01

    Full Text Available An accurate detection of anatomical structures in electrical impedance tomography (EIT is still at an early stage. Aorta detection in EIT is of special interest, since it would favor non-invasive assessment of hemodynamic processes in the body. Here, diverse EIT reconstruction parameters of the GREIT algorithm were systematically evaluated to detect the aorta after saline bolus injection in apnea. True aorta position and size were taken from computed tomography (CT. A comparison with CT showed that the smallest error for aorta displacement was attained for noise figure nf = 0.7, weighting radius rw = 0.15, and target size ts = 0.01. The spatial extension of the aorta was most precise for nf = 0.7, rw = 0.25, and ts = 0.07. Detection accuracy (F1-score was highest with nf = 0.6, rw = 0.15, and ts = 0.04. This work provides algorithm-related evidence for potentially accurate aorta detection in EIT after injection of a saline bolus.

  17. Dynamic computed tomography after bolus injection and infusion of perfluorooctylbromide (PFOB). Computertomographische Untersuchungen zur Dichtekinetik nach Bolusinjektion und Infusion von Perfluorooctylbromid (PFOB). Tierexperimentelle Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Adam, G.; Guenther, R.W.; Goertz, H.; Schiffer, C. (Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik); Prescher, A. (Technische Hochschule Aachen (Germany). Inst. fuer Anatomie); Bruchmueller, K. (Technische Hochschule Aachen (Germany). Inst. fuer Versuchstierkunde); Limmer, J. (Boehringer Ingelheim GmbH (Germany))

    1992-05-01

    We investigated the enhancement of the liver, the spleen, and of induced abscesses and the abdominal vessels after administration of 3 g/kg bodyweight Perfluoroocytlbromide (PFOB) on an animal model. Twenty-one rabbits each received the contrast medium as bolus injection and as slow infusion over half an hour. CT was performed between 2 and 48 hours after contrast medium application. Peak enhancement of the liver, the spleen and the liver abscess membrane was found between 24 and 48 hours after PFOB administration, independently of the application mode. Peak enhancement of the abdominal aorta and the IVC was observed within two hours after bolus injection. In this rabbit model PFOB permits best delineation of the vessels after bolus injection within the first two hours, while CT imaging of the liver, the spleen and the liver abscess membrane is best between 24 and 48 hours after contrast medium application, independent of the injection velocity. (orig.).

  18. Optical tracking of contrast medium bolus to optimize bolus shape and timing in dynamic computed tomography

    International Nuclear Information System (INIS)

    Eisa, Fabian; Brauweiler, Robert; Peetz, Alexander; Hupfer, Martin; Nowak, Tristan; Kalender, Willi A

    2012-01-01

    One of the biggest challenges in dynamic contrast-enhanced CT is the optimal synchronization of scan start and duration with contrast medium administration in order to optimize image contrast and to reduce the amount of contrast medium. We present a new optically based approach, which was developed to investigate and optimize bolus timing and shape. The time-concentration curve of an intravenously injected test bolus of a dye is measured in peripheral vessels with an optical sensor prior to the diagnostic CT scan. The curves can be used to assess bolus shapes as a function of injection protocols and to determine contrast medium arrival times. Preliminary results for phantom and animal experiments showed the expected linear behavior between dye concentration and absorption. The kinetics of the dye was compared to iodinated contrast medium and was found to be in good agreement. The contrast enhancement curves were reliably detected in three mice with individual bolus shapes and delay times of 2.1, 3.5 and 6.1 s, respectively. The optical sensor appears to be a promising approach to optimize injection protocols and contrast enhancement timing and is applicable to all modalities without implying any additional radiation dose. Clinical tests are still necessary. (note)

  19. Assessment of myocardial perfusion with MRI using a modified dual bolus method

    International Nuclear Information System (INIS)

    Husso, M; Sipola, P; Manninen, H; Vainio, P; Kuittinen, T; Hartikainen, J; Saarakkala, S; Töyräs, J; Kuikka, J

    2014-01-01

    Quantification of regional myocardial blood flow (rMBF) with first-pass magnetic resonance imaging (FP-MRI) requires two contrast agent injections (dual bolus technique), inducing error in the determined rMBF if the injections differ. We hypothesize that using input and residue curves of the same injection would be more reliable. We aim to introduce and evaluate a novel method to correct the high concentration arterial input function (AIF) for determination of rMBF. Sixteen patients with non-Hodgkin's lymphoma were examined before and after chemotherapy. The input function was solved by correcting initial high concentration AIF using the ratio of low and high contrast AIF areas, normalized by corresponding heart rates (modified dual bolus method). For comparison, the scaled low contrast AIF was used as an input function (dual bolus method). Unidirectional transfer coefficient K trans  was calculated using both methods. K trans -values determined with the dual bolus (0.81 ± 0.32 ml g −1  min −1 ) and modified dual bolus (0.77 ± 0.42 ml g −1  min −1 ) methods were in agreement (p = 0.21). Mean K trans -values increased from 0.76 ± 0.43 to 0.89 ± 0.55 ml g −1  min −1  after chemotherapy (p = 0.17). The modified dual bolus technique agrees with the dual bolus technique (R2 = 0.899) when the low and high contrast injections are similar. However, when this is not the case, the modified dual bolus technique may be more reliable. (paper)

  20. Correlations between aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time during CT angiography of aortoiliac and lower extremity arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakaya, Yasuhiro, E-mail: y-nakaya@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan); Kim, Tonsok; Hori, Masatoshi; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Higashihara, Hiroki; Tomoda, Kaname; Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita City, Osaka 565-0871 (Japan)

    2011-08-15

    Purpose: The purpose of this study was to investigate correlations between the aorto-popliteal bolus transit speed and aortic and popliteal bolus transit time in order to evaluate the possibility for prediction of bolus transit speed by single test injection technique. Materials and methods: Approval was obtained from our institutional review board for this study, which included 42 patients, from all of whom written informed consent was obtained. Low-dose serial CT scanning after injection of 12 ml contrast material (300 mg/ml) at a rate of 3 ml/s followed by saline flush was performed twice, first at the level of the upper abdomen and second at the level of the knee joint. The times needed to reach peak enhancement of the upper abdominal aorta (T-aorta) and bilateral popliteal arteries (T-popliteal) were obtained, and aorto-popliteal bolus transit speeds between the abdominal aorta and popliteal arteries were calculated. ABI was recorded for the bilateral feet. The Pearson's product-moment correlation coefficient was used to investigate the correlation between the bolus transit speed and T-aorta, T-popliteal, ABI, and patient age. Result: The respective correlation coefficients for bolus transit speed on the one hand and T-aorta, T-popliteal, ABI, patient age on the other were -0.50, -0.84, 0.36, and -0.52. Conclusion: The time to peak enhancement for popliteal arteries showed the strongest correlation with aorto-popliteal bolus transit speeds, and was considered to be the most accurate predictor for aorto-popliteal bolus transit speeds.

  1. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  2. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    International Nuclear Information System (INIS)

    Koujalagi, V; Semple, S; Ayres, J G; Ramesh, S L; Gunarathne, G P P

    2009-01-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  3. Development of a bolus injection system for regional deposition studies of nanoparticles in the human respiratory system

    Science.gov (United States)

    Koujalagi, V.; Ramesh, S. L.; Gunarathne, G. P. P.; Semple, S.; Ayres, J. G.

    2009-02-01

    This study presents the work carried out in developing a precision bolus injection system in order to understand the regional deposition of nanoparticles (NP) in human lung. A real-time control system has been developed that is capable of storing graphite NP, assessing human breathing pattern and delivering a bolus of the stored NP at a pre-determined instance of the inhalation phase of breathing. This will form the basis for further development of a system to deliver radioactive nanoparticles to enable 3-dimensional lung imaging using techniques such as positron emission tomography (PET). The system may then be used to better understand the actual regional deposition in human lung, which could validate or challenge the current computational lung models such as that published by the International Commission for Radiation Protection (ICRP-1994). A dose related response to inhaled PM can possibly be shown, which can be used to review the current workplace exposure limits (WELs).

  4. Split-bolus single-phase cardiac multidetector computed tomography for reliable detection of left atrial thrombus. Comparison to transesophageal echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Staab, W.; Zwaka, P.A.; Sohns, J.M.; Schwarz, A.; Lotz, J. [University Medical Center Goettingen Univ. (Germany). Inst. for Diagnostic and Interventional Radiology; Sohns, C.; Vollmann, D.; Zabel, M.; Hasenfuss, G. [Goettingen Univ. (Germany). Dept. of Cardiology and Pneumology; Schneider, S. [Goettingen Univ. (Germany). Dept. of Medical Statistics

    2014-11-15

    Evaluation of a new cardiac MDCT protocol using a split-bolus contrast injection protocol and single MDCT scan for reliable diagnosis of LA/LAA thrombi in comparison to TEE, optimizing radiation exposure and use of contrast agent. A total of 182 consecutive patients with drug refractory AF scheduled for PVI (62.6% male, mean age: 64.1 ± 10.2 years) underwent routine diagnostic work including TEE and cardiac MDCT for the evaluation of LA/LAA anatomy and thrombus formation between November 2010 and March 2012. Contrast media injection was split into a pre-bolus of 30 ml and main bolus of 70 ml iodinated contrast agent separated by a short time delay. In this study, split-bolus cardiac MDCT identified 14 of 182 patients with filling defects of the LA/LAA. In all of these 14 patients, abnormalities were found in TEE. All 5 of the 14 patients with thrombus formation in cardiac MDCT were confirmed by TEE. MDCT was 100% accurate for thrombus, with strong but not perfect overall results for SEC equivalent on MDCT.

  5. Total intravenous anaesthesia by boluses or by continuous rate infusion of propofol in mute swans (Cygnus olor).

    Science.gov (United States)

    Müller, Kerstin; Holzapfel, Judith; Brunnberg, Leo

    2011-07-01

    To investigate intravenous (IV) propofol given by intermittent boluses or by continuous rate infusion (CRI) for anaesthesia in swans. Prospective randomized clinical study. Twenty mute swans (Cygnus olor) (eight immature and 12 adults) of unknown sex undergoing painless diagnostic or therapeutic procedures. Induction of anaesthesia was with 8 mg kg(-1) propofol IV. To maintain anaesthesia, ten birds (group BOLI) received propofol as boluses, whilst 10 (group CRI) received propofol as a CRI. Some physiological parameters were measured. Anaesthetic duration was 35 minutes. Groups were compared using Mann-Whitney U-test. Results are median (range). Anaesthetic induction was smooth and tracheal intubation was achieved easily in all birds. Bolus dose in group BOLI was 2.9 (1.3-4.3) mg kg(-1); interval between and number of boluses required were 4 (1-8) minutes and 6 (4-11) boluses respectively. Total dose of propofol was 19 (12.3-37.1) mg kg(-1). Awakening between boluses was very abrupt. In group CRI, propofol infusion rate was 0.85 (0.8-0.9) mg kg(-1) minute(-1), and anaesthesia was stable. Body temperature, heart and respiratory rates, oxygen saturation (by pulse oximeter) and reflexes did not differ between groups. Oxygen saturations (from pulse oximeter readings) were low in some birds. Following anaesthesia, all birds recovered within 40 minutes. In 55% of all, transient signs of central nervous system excitement occurred during recovery. 8 mg kg(-1) propofol appears an adequate induction dose for mute swans. For maintenance, a CRI of 0.85 mg kg(-1) minute(-1) produced stable anaesthesia suitable for painless clinical procedures. In contrast bolus administration, was unsatisfactory as birds awoke very suddenly, and the short intervals between bolus requirements hampered clinical procedures. Administration of additional oxygen throughout anaesthesia might reduce the incidence of low arterial haemoglobin saturation. © 2011 The Authors. Veterinary Anaesthesia and

  6. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality.

    Science.gov (United States)

    Jost, Gregor; Endrikat, Jan; Pietsch, Hubertus

    2017-01-01

    To compare injector-based contrast agent (CA) administration with hand injection in magnetic resonance angiography (MRA). Gadobutrol was administered in 6 minipigs with 3 protocols: (a) hand injection (one senior technician), (b) hand injection (6 less-experienced technicians), and (c) power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  7. The Impact of Injector-Based Contrast Agent Administration on Bolus Shape and Magnetic Resonance Angiography Image Quality

    Directory of Open Access Journals (Sweden)

    Gregor Jost

    2017-04-01

    Full Text Available Objective: To compare injector-based contrast agent (CA administration with hand injection in magnetic resonance angiography (MRA. Methods: Gadobutrol was administered in 6 minipigs with 3 protocols: (a hand injection (one senior technician, (b hand injection (6 less-experienced technicians, and (c power injector administration. The arterial bolus shape was quantified by test bolus measurements. A head and neck MRA was performed for quantitative and qualitative comparison of signal enhancement. Results: A significantly shorter time to peak was observed for protocol C, whereas no significant differences between protocols were found for peak height and bolus width. However, for protocol C, these parameters showed a much lower variation. The MRA revealed a significantly higher signal-to-noise ratio for injector-based administration. A superimposed strong contrast of the jugular vein was found in 50% of the hand injections. Conclusions: Injector-based CA administration results in a more standardized bolus shape, a higher vascular contrast, and a more robust visualization of target vessels.

  8. Transversus Abdominis Plane Catheter Bolus Analgesia after Major Abdominal Surgery

    Directory of Open Access Journals (Sweden)

    Nils Bjerregaard

    2012-01-01

    Full Text Available Purpose. Transversus abdominis plane (TAP blocks have been shown to reduce pain and opioid requirements after abdominal surgery. The aim of the present case series was to demonstrate the use of TAP catheter injections of bupivacaine after major abdominal surgery. Methods. Fifteen patients scheduled for open colonic resection surgery were included. After induction of anesthesia, bilateral TAP catheters were placed, and all patients received a bolus dose of 20 mL bupivacaine 2.5 mg/mL with epinephrine 5 μg/mL through each catheter. Additional bolus doses were injected bilaterally 12, 24, and 36 hrs after the first injections. Supplemental pain treatment consisted of paracetamol, ibuprofen, and gabapentin. Intravenous morphine was used as rescue analgesic. Postoperative pain was rated on a numeric rating scale (NRS, 0–10 at regular predefined intervals after surgery, and consumption of intravenous morphine was recorded. Results. The TAP catheters were placed without any technical difficulties. NRS scores were ≤3 at rest and ≤5 during cough at 4, 8, 12, 18, 24, and 36 hrs after surgery. Cumulative consumption of intravenous morphine was 28 (23–48 mg (median, IQR within the first 48 postoperative hours. Conclusion. TAP catheter bolus injections can be used to prolong analgesia after major abdominal surgery.

  9. Esophageal contractions, bolus transit and perception of transit after swallows of liquid and solid boluses in normal subjects

    Directory of Open Access Journals (Sweden)

    Juciléia Dalmazo

    2012-12-01

    Full Text Available CONTEXT: Esophageal dysphagia is the sensation that the ingested material has a slow transit or blockage in its normal passage to the stomach. It is not always associated with motility or transit alterations. OBJECTIVES: To evaluate in normal volunteers the possibility of perception of bolus transit through the esophagus after swallows of liquid and solid boluses, the differences in esophageal contraction and transit with these boluses, and the association of transit perception with alteration of esophageal contraction and/or transit. METHODS: The investigation included 11 asymptomatic volunteers, 4 men and 7 women aged 19-58 years. The subjects were evaluated in the sitting position. They performed swallows of the same volume of liquid (isotonic drink and solid (macaroni boluses in a random order and in duplicate. After each swallow they were asked about the sensation of bolus passage through the esophagus. Contractions and transit were evaluated simultaneously by solid state manometry and impedance. RESULTS: Perception of bolus transit occurred only with the solid bolus. The amplitude and area under the curve of contractions were higher with swallows of the solid bolus than with swallows of the liquid bolus. The difference was more evident in swallows with no perception of transit (n = 12 than in swallows with perception (n = 10. The total bolus transit time was longer for the solid bolus than for the liquid bolus only with swallows followed by no perception of transit. CONCLUSION: The results suggest that the perception of esophageal transit may be the consequence of inadequate adaptation of esophageal transit and contraction to the characteristics of the swallowed bolus.

  10. MnDPDP enhancement in rabbit liver after intravenous bolus injection and slow infusion

    International Nuclear Information System (INIS)

    Thorstensen, Oe.; Isberg, B.; Jorulf, H.; Westman, L.; Svahn, U.; Venizelos, N.

    1997-01-01

    Purpose: To investigate the MR-enhancing effect of mangafodipir trisodium (MnDPDP, Teslascan) in the rabbit liver in relation to dose, mode of administration and imaging window. Material and Methods: MnDPDP was administered to 18 rabbits at a dose of 10 μmol/kg or 20 μmol/kg, as a bolus injection or infusion. MR imaging of the liver was performed at different time intervals. Results: Peak liver enhancement was typically observed 10-30 min after administration and the enhancement declined with a half-time of about 5 h. This pattern was observed in all sequences (SE 400/15, FLASH, and SE 132/10), with both doses and with both rates of administration. The peak enhancement was greater, though not significantly so after 20 μmol/kg than after 10 μmol/kg. A higher relative peak signal was observed with SE 132/10 than with FLASH or SE 400/15. (orig./AJ)

  11. Evaluation of a bolus/infusion protocol for 11C-ABP688, a PET tracer for mGluR5

    International Nuclear Information System (INIS)

    Burger, Cyrill; Deschwanden, Alexandra; Ametamey, Simon; Johayem, Anass; Mancosu, Bruno; Wyss, Matthias; Hasler, Gregor; Buck, Alfred

    2010-01-01

    11 C-ABP-688 is a selective tracer for the mGluR5 receptor. Its kinetics is fast and thus favourable for an equilibrium approach to determine receptor-related parameters. The purpose of this study was to test the hypothesis that the pattern of the 11 C-ABP688 uptake using a bolus-plus-infusion (B/I) protocol at early time points corresponds to the perfusion and at a later time point to the total distribution volume. Methods: A bolus and a B/I study (1 h each) was performed in five healthy male volunteers. With the B/I protocol, early and late scans were normalized to gray matter, cerebellum and white matter. The same normalization was done on the maps of the total distribution volume (Vt) and K 1 which were calculated in the study with bolus only injection and the Logan method (Vt) and a two-tissue compartment model (K 1 ). Results: There was an excellent correlation close to the identity line between the pattern of the late uptake in the B/I study and Vt of the bolus-only study for all three normalizations. The pattern of the early uptake in the B/I study correlated well with the K 1 maps, but only when normalized to gray matter and cerebellum, not to white matter. Conclusion: It is demonstrated that with a B/I protocol the 11 C-ABP688 distribution in late scans reflects the pattern of the total distribution volume and is therefore a measure for the density pattern of mGluR5. The early scans following injection are related to blood flow, although not in a fully quantitative manner. The advantage of the B/I protocol is that no arterial blood sampling is required, which is advantageous in clinical studies.

  12. The influence of carbon monoxide bolus on the measurement of total haemoglobin mass using the optimized CO-rebreathing method

    International Nuclear Information System (INIS)

    Turner, G; Richardson, A J; Maxwell, N S; Pringle, J S M; Ingham, S A; Fudge, B W

    2014-01-01

    The optimized carbon monoxide (CO) rebreathing method (oCOR-method) is routinely used to measure total haemoglobin mass (tHbmass). The tHbmass measure is subject to a test-retest typical error of ∼2%, mostly from the precision of carboxyhaemoglobin (HbCO) measurement. We hypothesized that tHbmass would be robust to differences in the bolus of CO administered during the oCOR-method. Twelve participants (ten males and two females; age 27 ± 6 yr, height 177 ± 11 cm and mass 73.9 ± 12.1 kg) completed the oCOR-method on four occasions. Different bolus of CO were administered (LOW: 0.6 ml kg −1 ; MED 1 : 1.0 ml kg −1  and HIGH: 1.4 ml kg −1 ); to determine the reliability of MED 1 , a second trial was conducted (MED 2 ). tHbmass was found to be significantly less from the HIGH CO bolus (776 ± 148 g) when compared to the LOW CO (791 ± 149 g) or MED 1  CO (788 ± 149 g) trials. MED 2  CO was 785 ± 150 g. The measurement of tHbmass is repeatable to within 0.8%, but a small and notable difference was seen when using a HIGH CO bolus (1.4 to 1.9% less), potentially due to differences in CO uptake kinetics. Previously, an improved precision of the oCOR-method was thought to require a higher bolus of CO (i.e. larger ▵%HbCO), as commercial hemoximeters only estimate %HbCO levels to a single decimal place (usually ± 0.1%). With the new hemoximeter used in this study, a bolus of 1.0 ml kg −1  allows adequate precision with acceptable safety. (note)

  13. Gastrostomy feeding tube - bolus

    Science.gov (United States)

    Feeding - gastrostomy tube - bolus; G-tube - bolus; Gastrostomy button - bolus; Bard Button - bolus; MIC-KEY - bolus ... KEY, 3 to 8 weeks after surgery. These feedings will help your child grow strong and healthy. ...

  14. Intravenous Bolus versus Continuous Infusion of Famotidine or Ranitidine on 24 H Intragastric Acidity in Fasting Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    ABR Thomson

    1995-01-01

    Full Text Available Infusions of H2-receptor antagonists may be clinically indicated to maintain intragastric pH above 4 to reduce acute gastric mucosal lesions or to treat patients with bleeding peptic ulcers. Eight fasting healthy volunteers were randomly assigned to receive ranitidine infusion alone (150 mg/day, ranitidine infusion plus 50 mg bolus injection of ranitidine (total of 200 mg/day, famotidine infusion alone (40 mg/day or famotidine infusion plus 40 mg bolus injection of famotidine (total of 80 mg/day. Gastric fluid contents were aspirated for 24 h and collected as half-hourly samples in which pH measurements were made. Measures analyzed were mean and median pH, percentage pH at or below 3, 4 or 5 for the 24 h period, daytime, evening and nighttime. The data for each of the variables were analyzed as a Latin square crossover design of variance therapy; base pH before treatment administration in each crossover phase was employed as the covariant. Significant differential treatment means were tested by Newman-Keul’s multiple range test at the 5% level of significance. The mean and median evening pH were higher after famotidine than after ranitidine infusion, but all other pH readings were similar when using these doses. The addition of an initial loading bolus of 50 mg ranitidine to the ranitidine infusion did not result in any added differences in pH, whereas the addition of an initial loading bolus of 40 mg famotidine to the famotidine infusion resulted in a higher 24 h median pH, as well as a lower percentage of pH values of 4 or below, 16.6% versus 28.5%, P<0.05. However, the loading doses of ranitidine and famotidine were not equivalent in potency, and studies are needed to compare the potency of equivalent doses of ranitidine and famotidine when given by bolus plus infusion. Also the clinical relevance of these findings needs to be explored further in the type of individuals potentially requiring intravenous H2-receptor antagonists.

  15. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  16. Capillary permeability of 99mTc-DTPA in canine myocardium determined by intracoronary bolus injection and residue detection

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Efsen, F; Haunsø, S

    1989-01-01

    chest dogs (group A) these indicators were administered separately as bolus injections into a cannulated diagonal branch of the left anterior descending coronary artery (LAD) and the curve of the response function was recorded by external activity registration. In further experiments on closed and open...... chest dogs (group B) 99mTc-DTPA was injected via a coronary angiography catheter into the ostium of the left coronary artery and the response curve was obtained by external registration. Regional myocardial perfusion coefficients were determined by the local 133xenon washout technique and from kinetic...... by local 133Xe washout technique. Mean values of the extraction fractions (E) were 0.463 and 0.475 for 99mTc-DTPA and 51Cr-EDTA, and the permeability-surface area products (PdS) were 52.8 and 57.5 ml.min-1.100 g-1 respectively. At the conventional capillary surface area estimate of 500 cm2.g-1...

  17. Technology for bolus verification in proton therapy

    Science.gov (United States)

    Shipulin, K. N.; Mytsin, G. V.; Agapov, A. V.

    2015-01-01

    To ensure the conformal depth-dose distribution of a proton beam within a target volume, complex shaped range shifters (so-called boluses), which account for the heterogeneous structure of patient tissue and organs in the beam path, were calculated and manufactured. The precise manufacturing of proton compensators used for patient treatment is a vital step in quality assurance in proton therapy. In this work a software-hardware complex that verifies the quality and precision of bolus manufacturing at the Medico-Technical Complex (MTC) was developed. The boluses consisted of a positioning system with two photoelectric biosensors. We evaluated 20 boluses used in proton therapy of five patients. A total number of 2562 experimental points were measured, of which only two points had values that differed from the calculated value by more than 0.5 mm. The other data points displayed a deviation within ±0.5 mm from the calculated value. The technology for bolus verification developed in this work can be used for the high precision testing of geometrical parameters of proton compensators in radiotherapy.

  18. Bolus dose response characteristics of single chain urokinase plasminogen activator and tissue plasminogen activator in a dog model of arterial thrombosis.

    Science.gov (United States)

    Badylak, S F; Voytik, S; Klabunde, R E; Henkin, J; Leski, M

    1988-11-15

    Tissue plasminogen activator (t-PA) and single chain urokinase-plasminogen activator (scu-PA) are relatively "fibrin-specific" thrombolytic drugs with short plasma half lives of 6-8 minutes. Most treatment regimens with these agents utilize a bolus injection followed by continuous drug infusion, usually combined with anticoagulant therapy. The purpose of this study was to establish the dose-response characteristics for scu-PA and t-PA, when given as a single intravenous bolus injection, in a dog model of arterial thrombosis. Eight groups of 6 dogs each were given one of the following doses of scu-PA (mg/kg): 0.20, 0.50, 1.00, 2.00; or t-PA: 0.05, 0.10, 0.20; or an equivalent amount of saline (control group). All doses were given as a single bolus injection 60 minutes after formation of a totally occlusive femoral artery thrombus. Thrombolysis was measured by monitoring the continuous decrement of 125I activity from a radiolabelled thrombus. Ninety minutes after drug injection, all scu-PA treated dogs showed greater thrombolysis (30%, 45%, 56%, and 67%, respectively) than the control group (15%, p less than 0.01). The 0.10 and 0.20 mg/kg t-PA treated dogs showed greater thrombolysis (35% and 49%, respectively) than the control group (15%, p less than 0.01). Both scu-PA and t-PA caused a partial and dose-dependent decrease in alpha 2-antiplasmin activity but scu-PA caused a greater depletion (72% vs. 18%, respectively, p less than 0.05) at 60 minutes after the highest dose of drug administration. Both drugs showed a longer than expected thrombolytic effect based upon the known half lives. Neither drug caused significant changes in the prothrombin time, activated partial thromboplastin time, thrombin time, hematocrit, platelet count, or fibrin degradation product concentration. Single bolus injections of scu-PA and t-PA produce safe and effective thrombolysis in this dog model of arterial thrombosis.

  19. "The relationship between pharmacokinetic variables and pharmacodynamic profiles of bolus versus continuous infusion of furosemide in critically ill patients"

    Directory of Open Access Journals (Sweden)

    "Mojtaba Mojtahedzadeh

    2005-05-01

    Full Text Available In this investigation, the pharmacokinetic variables of continuous infusion and intermittent bolus injection of furosemide and the possible relationship between its pharmacokinetic characteristics and pharmacodynamic profile among intensive care unit (ICU patients were studied. In this prospective, randomized, clinical trial, twelve patients received IV bolus of 20 mg of the drug during 3 hours period and, the drug dose was doubled, when the urine output was less than 1 ml/kg/h (group 1. The other nine patients received a continuous intravenous furosemide infusion at the rate of 0.1 mg/kg/h (group 2. The amount of furosemide in serum was measured by high performance liquid chromatography (HPLC. Results showed a positive correlation between plasma clearance of furosemide and its diuretic activity (P=0.01. The pharmacokinetic parameters such as Vd (l, CL (ml/min, Ke (min-1 and t½ (min in continuous infusion patients were not significantly differed from the bolus patients (P-values 0.5, 0.9, 0.9,0.9, respectively. Nevertheless the observed plasma clearance of drug in the continuous infusion group was clinically higher than bolus injection group and as a result the cumulative urine output per hour per mg of furosemide in a continuous infusion was observed to be higher than bolus(P=0.2. Changes in serum sodium and potassium were similar for both groups, but bolus injection patients were associated with higher potassium depletion (P=0.001. Therefore, continuous infusion seems to be better means of diuretic therapy in critically ill patients.

  20. A study on developing customized bolus using 3D prints

    International Nuclear Information System (INIS)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok

    2015-01-01

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D max , D min , D mean , D 95% and V 95% in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm 3 at the customized bolus. And it was average 29.6cm 3 at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D max , D min , D mean , D 95% , V 95% of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D max , D min , D mean , D 95% , V 95% of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D max , D min , D mean , D 95% , V 95% of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against

  1. Use of an automated bolus calculator in MDI-treated type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Meldgaard, Merete; Serifovski, Nermin

    2012-01-01

    To investigate the effect of flexible intensive insulin therapy (FIIT) and an automated bolus calculator (ABC) in a Danish type 1 diabetes population treated with multiple daily injections. Furthermore, to test the feasibility of teaching FIIT in a 3-h structured course....

  2. A study on developing customized bolus using 3D prints

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Sang Min; Yang, Jin Ho; Lee, Seung Hyun; Kim, Jin Uk; Yeom, Du Seok [Dept. of Proton Therapy Center, National Cancer Center, Ilsan (Korea, Republic of)

    2015-06-15

    3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare D{sub max}, D{sub min}, D{sub mean}, D{sub 95%} and V{sub 95%} in treatment plan through Eclipse. Customized bolus production period took about 3 days. The total volume of air gap was average 3.9 cm{sup 3} at the customized bolus. And it was average 29.6cm{sup 3} at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1 cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the D{sub max}, D{sub min}, D{sub mean}, D{sub 95%}, V{sub 95%} of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. The

  3. Bolus characteristics based on Magnetic Resonance Angiography

    Directory of Open Access Journals (Sweden)

    Bi Xiaoming

    2006-10-01

    Full Text Available Abstract Background A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA. Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA for adaptive controller design and validation. Methods MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design. Results The maximum speed of the bolus in the aorta ranged from 5–13 cm/s and the dwell time ranged from 7–13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location. Conclusion The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.

  4. Distribution and mixing of a liquid bolus in pleural space.

    Science.gov (United States)

    Bodega, Francesca; Tresoldi, Claudio; Porta, Cristina; Zocchi, Luciano; Agostoni, Emilio

    2006-02-28

    Distribution and mixing time of boluses with labeled albumin in pleural space of anesthetized, supine rabbits were determined by sampling pleural liquid at different times in various intercostal spaces (ics), and in cranial and caudal mediastinum. During sampling, lung and chest wall were kept apposed by lung inflation. This was not necessary in costo-phrenic sinus. Here, 10 min after injection, lung inflation increased concentration of labeled albumin by 50%. Lung inflation probably displaces some pleural liquid cranio-caudally, increasing labeled albumin concentration caudally to injection point (6th ics), and decreasing it cranially. Boluses of 0.1-1 ml did not preferentially reach mediastinal regions, as maintained by others. Time for an approximate mixing was approximately 1 h for 0.1 ml, and approximately 30 min for 1 ml. This relatively long mixing time does not substantially affect determination of contribution of lymphatic drainage through stomata to overall removal of labeled albumin from 0.3 ml hydrothoraces lasting 3 h [Bodega, F., Agostoni, E., 2004. Contribution of lymphatic drainage through stomata to albumin removal from pleural space. Respir. Physiol. Neurobiol. 142, 251-263].

  5. Urinary excretion and patterns of protein binding of iodipamide (Biligrafin forte). A comparison of the infusion technique with the single bolus injection in intravenous cholangiography

    Energy Technology Data Exchange (ETDEWEB)

    Husband, J; Saxton, H M [Guy' s Hospital, London (UK)

    1978-01-01

    It has been suggested that the bile ducts are seen better during intravenous cholangiography when the contrast medium is given by infusion rather than by injection in a single bolus. As an explanation, it has been proposed that a greater amount of contrast medium is bound to plasma proteins after infusion, resulting in a smaller quantity of contrast medium being excreted in the urine, so leaving a larger total for excretion by the liver. In this study, the urinary excretion of /sup 125/I labelled iodipamide methylglucamine (50% w/v Biligrafin forte) has been measured in 42 patients. The patients were divided into two groups. One group received a slow infusion of radioactive iodipamide over 45 minutes and the other an intravenous injection over five minutes. When a relatively high dose (0.6 mg/kg body weight) was used, no difference in urinary excretion was noted between these two groups; but with a lower dose (0.2 mg/kg body weight), slow infusion resulted in a reduced urinary excretion; however the total difference in contrast lost in the urine was too small to affect biliary concentration. The patterns of protein binding of iodipamide have been examined in 12 of these patients. The results showed that at the low dose a higher percentage of radioactive iodipamide was bound to protein in patients given contrast by infusion. There was clear evidence that the contrast binding capacity of plasma was limited so that with higher doses, much contrast remained unbound. At any given dose level, there was inverse correlation between the proportion of contrast bound to protein and the urinary excretion. The factors affecting contrast binding in individual subjects were not clear.

  6. Association between swallow perception and esophageal bolus clearance in patients with globus sensation.

    Science.gov (United States)

    Chen, Chien-Lin; Yi, Chih-Hsun; Liu, Tso-Tsai

    2013-04-01

    Globus sensation is common, but its pathogenesis is not yet clear. Our purpose was to investigate subjective perception of swallowing and esophageal motility by combined multichannel intraluminal impedance and manometry (MII-EM) for patients with globus sensation. Combined MII-EM was performed for 25 globus patients and 15 healthy controls. Swallows were abnormal if hypocontractivity or simultaneous contractions occurred. Esophageal bolus transit was incomplete if bolus exit was not found at one or more of all measurement sites. Perception of each swallow was assessed by use of a standardized scoring system, and was enhanced if the score was >1. Few globus patients reported enhanced perception during viscous or solid swallows. Incomplete bolus transit and enhanced perception occurred similarly between viscous and solid boluses. Agreement between enhanced perception and proximal bolus clearance was greater during solid swallows (κ = 0.45, 95 % CI: 0.32-0.58) than during viscous swallows (κ = 0.13, 95 % CI: 0-0.25) (P perception and total bolus clearance was greater during solid swallows (κ = 0.46, 95 % CI: 0.34-0.58) than during viscous swallows (κ = 0.11, 95 % CI: 0-0.22) (P perception is uncommon in patients with globus sensation, although there is a significant association between enhanced esophageal perception and solid bolus clearance. Application of a solid bolus may help better delineation of the interrelationship between the subjective perception of bolus passage and the objective measurement of bolus clearance.

  7. Efficacy of a Targeted Drug Delivery on-Demand Bolus Option for Chronic Pain.

    Science.gov (United States)

    Bolash, Robert B; Niazi, Tariq; Kumari, Meera; Azer, Gerges; Mekhail, Nagy

    2018-03-01

    Intrathecal targeted drug delivery systems historically required physician office visits for dose adjustment to manage fluctuating pain. A wireless device now enables patients to supplement their basal intrathecal infusion with a programmed on-demand bolus dose. We sought to quantify the change in oral breakthrough opioid need associated with the use of an intrathecal bolus in comparison to those treated with the basal infusion alone. Demographic, dosage, bolus usage and longevity data were extracted from the historical medical record of 69 patients (18/51 bolus/nonbolus) followed continuously at our center. Medication consumption and Pain Disability Index measures were obtained at baseline and most recent follow-up. Among patients with the bolus option, only 2 (11%; confidence interval [CI] 0% to 26%) continued to require oral opiates to manage breakthrough pain compared to 29 (57%; CI 43% to 71%) without the bolus option. The Pain Disability Index score decreased by 19% in patients with the bolus option and by 25% in those with the basal infusion. Total daily intrathecal opioid intake was 34% lower in the group with the bolus device. Utilizing an intrathecal bolus to treat incident pain was a safe way to manage unpredictable breakthrough pain and may represent a cost-saving opportunity by eliminating the need for oral analgesic medications. © 2017 World Institute of Pain.

  8. Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial

    NARCIS (Netherlands)

    Mungroop, Timothy H.; van Samkar, Ganapathy; Geerts, Bart F.; van Dieren, Susan; Besselink, Marc G.; Veelo, Denise P.; Lirk, Philipp

    2017-01-01

    Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine

  9. Modeling the retention of rumen boluses for the electronic identification of goats.

    Science.gov (United States)

    Carné, S; Caja, G; Ghirardi, J J; Salama, A A K

    2011-02-01

    We constructed a regression model to estimate the retention of electronic boluses in goats. With this aim, 2,482 boluses were administered to goats from dairy (Murciano-Granadina, n=1,326; French Alpine, n=381) and meat (Blanca de Rasquera, n=532) breeds. A total of 19 bolus types made of materials (ceramic, plastic tubes filled with concrete or silicone, and ballasts) differing in their specific gravity (SG) were used, thereby obtaining a wide variation in bolus features: diameter (9 to 22 mm), length (37 to 84 mm), weight (5 to 111 g), volume (2.6 to 26 mL), and SG (1.0 to 5.5). Each bolus contained a half-duplex glass encapsulated transponder (32 × 3.8mm) and was administered using adapted balling guns. Murciano-Granadina and Blanca de Rasquera goats also wore 2 visual plastic ear tags: V1 (double flag, 5.1g) and V2 (flag-button, 4.2g). No data on ear tags in French Alpine goats was available. Bolus and ear tag retention [(retained/monitored) × 100] was recorded for at least 1 yr. Dynamic reading efficiency [(dynamic reading/static reading) × 100] was also evaluated from 1,496 bolus readings. No administration incidences or apparent negative behavior or performance effects were observed for any bolus type. Static reading efficiency of retained boluses was 100%, except for the prototypes with metal ballasts, which yielded a 93.3% reading efficiency. Retention of metal-ballasted boluses was confirmed using x-ray equipment. Excluding ballasted boluses, a 99.5% dynamic reading efficiency was obtained. Ear tag losses were 6.5% for V1 and 3.7% for V2, ranging from 3.2 to 7.8% depending on ear tag type and goat breed. Bolus retention varied (0 to 100%) according to their physical features. Obtained data allowed the fitting of a logistic model of bolus retention rate according to bolus volume and weight (R(2) = 0.98); the SG was implicitly considered. Estimated weight and SG to produce medium- (15 mL) and standard-sized (22 mL) boluses for 99.95% retention rate in

  10. Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

    Science.gov (United States)

    Rossetti, Paolo; Vehí, Josep; Revert, Ana; Calm, Remei; Bondia, Jorge

    2012-03-01

    Since the early 2000s, there has been an exponentially increasing development of new diabetes-applied technology, such as continuous glucose monitoring, bolus calculators, and "smart" pumps, with the expectation of partially overcoming clinical inertia and low patient compliance. However, its long-term efficacy in glucose control has not been unequivocally proven. In this issue of Journal of Diabetes Science and Technology, Sussman and colleagues evaluated a tool for the calculation of the prandial insulin dose. A total of 205 insulin-treated patients were asked to compute a bolus dose in two simulated conditions either manually or with the bolus calculator built into the FreeStyle InsuLinx meter, revealing the high frequency of wrong calculations when performed manually. Although the clinical impact of this study is limited, it highlights the potential implications of low diabetesrelated numeracy in poor glycemic control. Educational programs aiming to increase patients' empowerment and caregivers' knowledge are needed in order to get full benefit of the technology. © 2012 Diabetes Technology Society.

  11. Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

    Science.gov (United States)

    Sussman, Allen; Taylor, Elizabeth J; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Lawrence, Andrew; Ng, Ronald

    2012-03-01

    Patients consider multiple parameters in adjusting prandial insulin doses for optimal glycemic control. Difficulties in calculations can lead to incorrect doses or induce patients to administer fixed doses, rely on empirical estimates, or skip boluses. A multicenter study was conducted with 205 diabetes subjects who were on multiple daily injections of rapid/ short-acting insulin. Using the formula provided, the subjects manually calculated two prandial insulin doses based on one high and one normal glucose test result, respectively. They also determined the two doses using the FreeStyle InsuLinx Blood Glucose Monitoring System, which has a built-in, automated bolus calculator. After dose determinations, the subjects completed opinion surveys. Of the 409 insulin doses manually calculated by the subjects, 256 (63%) were incorrect. Only 23 (6%) of the same 409 dose determinations were incorrect using the meter, and these errors were due to either confirmed or potential deviations from the study instructions by the subjects when determining dose with meter. In the survey, 83% of the subjects expressed more confidence in the meter-calculated doses than the manually calculated doses. Furthermore, 87% of the subjects preferred to use the meter than manual calculation to determine prandial insulin doses. Insulin-using patients made errors in more than half of the manually calculated insulin doses. Use of the automated bolus calculator in the FreeStyle InsuLinx meter minimized errors in dose determination. The patients also expressed confidence and preference for using the meter. This may increase adherence and help optimize the use of mealtime insulin. © 2012 Diabetes Technology Society.

  12. Bolus use in radiotherapy

    Directory of Open Access Journals (Sweden)

    Sérgio Spezzia

    2017-01-01

    Full Text Available Preliminary to the radiation therapy, it is posisble to develop a therapeutic device contained in the buccomaxillofacial prosthesis resources, creating the bolus. Bolus are materials used to increase the dose on the entrance surface of a field or to compensate for a lack of tissue. The requirements for a material to be used as a bolus include to interact with ionizing radiations in a similar manner to tissues and to be soft enough to allow its molding to the patient’s contour. There are various materials available for this purpose, however, with a relatively high cost. Some inexpensive options can also be used, such as pressed cellophane and wet gauze, however, these materials do not present favorable malleability and do not offer true reproducibility. The aim of this article was to ascertain whether there is harmonious knowledge of this technique by dental surgeons, medical oncologists and radiotherapists. This technique or device minimizes the deleterious effects resulting from exposure to radiation. It was concluded the bolus can reduce possible complications arising from radiation therapy, concomitantly offering improved living conditions during treatment.

  13. Optimized enhancement in helical CT: Experiences with a real-time bolus tracking system in 628 patients

    International Nuclear Information System (INIS)

    Kirchner, J.; Kickuth, R.; Laufer, U.; Noack, M.; Liermann, D.

    2000-01-01

    AIMS: Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. MATERIALS AND METHODS: In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. RESULTS: There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). CONCLUSION: Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Kirchner, J. (2000). Clinical Radiology 55, 368-373

  14. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    Science.gov (United States)

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  15. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    OpenAIRE

    Mohammadreza Moshari; Bahman Malek; Mohammadreza Minator-Sajjadi; Maryam Vosoghian; Mastaneh Dahi; Mahshid Ghasemi; Razieh Shekari

    2018-01-01

    AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion), were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B) of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (...

  16. Pharmacokinetics of Perfluorobutane after Intra-Venous Bolus Injection of Sonazoid in Healthy Chinese Volunteers.

    Science.gov (United States)

    Li, Pengfei; Hoppmann, Susan; Du, Ping; Li, Huiling; Evans, Paul M; Moestue, Siver A; Yu, Weiyue; Dong, Fang; Liu, Hongchuan; Liu, Lihong

    2017-05-01

    Sonazoid is an ultrasound contrast agent based on microbubbles (MB) containing perfluorobutane (PFB) gas. Sonazoid is approved in Japan, Korea and Norway for contrast-enhanced ultrasonography of focal liver lesions and focal breast lesions (Japan only). The objective of this study was to determine the pharmacokinetics (PKs) and safety of Sonazoid in Chinese healthy volunteers (HVs) and to evaluate the potential for ethnic differences in PKs between Chinese and Caucasian HVs. Sonazoid was administered as an intra-venous bolus injection at the clinical dose of 0.12 μL or 0.60 μL MB/kg body weight to two groups of eight Chinese HVs. Expired air and blood samples were collected and analyzed using a validated gas chromatographic tandem mass spectrometry method, and the main PK parameters were calculated. The highest PFB concentrations in blood were observed shortly after intra-venous administration of Sonazoid, and elimination of PFB was rapid. In the 0.12 μL MB/kg body weight cohort, PFB concentrations above the limit of quantification were observed for only 10 to 15 min post-injection. In the 0.60 μL MB/kg body weight cohort, PFB concentrations above the limit of quantification were observed for 60 min post-injection, and the shape of the elimination curve suggested a biphasic elimination profile. The maximum observed concentration (C max ) values of PFB in blood were 2.3 ± 1.1 and 19.1 ± 9.2 ng/g for the 0.12 and 0.60 μL MB/kg body weight dose groups (mean ± standard deviation). Area under the curve values were 10.1 ± 2.7 and 90.1 ± 38.3 ng × min/g for the 0.12 and 0.60 μL MB/kg body weight dose groups. C max values of PFB in exhaled air were 0.35 ± 0.2 and 2.4 ± 0.7 ng/mL for the 0.12 and 0.60 μL MB/kg body weight dose groups. Assessment of laboratory parameters, vital signs, oxygen saturation and electrocardiograms revealed no changes indicative of a concern. The PK profile and safety data generated in the Chinese

  17. Dual-phase helical CT using bolus triggering technique: optimization of transition time

    International Nuclear Information System (INIS)

    Choi, Young Ho; Kim, Tae Kyoung; Park, Byung Kwan; Koh, Young Hwan; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    To optimize the transition time between the triggering point in monitoring scanning and the initiation of diagnostic hepatic arterial phase (HAP) scanning in hepatic spiral CT, using a bolus triggering technique. One hundred consecutive patients with focal hepatic lesion were included in this study. Patients were randomized into two groups. Transition times of 7 and 11 seconds were used in group 1 and 2, respectively. In all patients, bolus triggered HAP spiral CT was obtained using a semi-automatic bolus tracking program after the injection of 120mL of non-ionic contrast media at a rate of 3mL/sec. When aortic enhancement reached 90 HU, diagnostic HAP scanning began after a given transition time. From images of group 1 and group 2, the degree of parenchymal enhancement of the liver and tumor-to-liver attenuation difference were measured. Also, for qualitative analysis, conspicuity of the hepatic artery and hypervascular tumor was scored and analyzed. Hepatic parenchymal enhancement on HAP was 12.07 + /-6.44 HU in group 1 and 16.03 + /-5.80 HU in group 2 (p .05). In the evaluation of conspicuity of hepatic artery, there was no statistically significant difference between the two groups (p > .05). The conspicuity of hypervascular tumors in group 2 was higher than in group 1 (p < .05). HAP spiral CT using a bolus triggering technique with a transition time of 11 seconds provides better HAP images than when the transition time is 7 seconds

  18. Tranexamic Acid in Bolus Alone Vs Bolus and Continuous Infusion in Hip Arthroscopy

    OpenAIRE

    Fatih Karaaslan; Roberto Seijas; Andrea Sallent; Oscar Ares; Wenceslao Espinosa; Pedro Alvarez; Ramón Cugat; Patricia Lopez

    2017-01-01

    AIM: the present study examines the effects of tranexamic acid (TXA) on reducing blood loss during hip arthroscopy, comparing two different methods of administration (bolus vs infusion). METHODS: a prospective study with 70 patients undergoing hip arthroscopy was carried out. The patients within the TXA infusion group (group A) received TXA an 2-g intravenous bolus 30 min before skin incision intravenously followed by 10 mg/kg/h infusion (continued during the entire surgery)...

  19. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul, (Korea, Republic of)

    2016-06-15

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  20. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    International Nuclear Information System (INIS)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho

    2016-01-01

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  1. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  2. Pharyngeal Pressure and Timing During Bolus Transit

    Science.gov (United States)

    Walczak, Chelsea C.; Jones, Corinne A.; McCulloch, Timothy M.

    2018-01-01

    Determining intrabolus pressure (IBP) at the upper esophageal sphincter (UES) and in the esophagus has given compelling evidence that IBP can be a predictor for swallowing dysfunction. Studies have looked most superiorly at the low hypopharynx region but there has been no inquiry into what IBP measures throughout the entire pharynx can tell us. We present a study to describe the pressures within and surrounding the moving bolus throughout the pharynx and into the UES. Simultaneous HRM and videofluoroscopy were performed in 10 healthy subjects swallowing ten 10 mL thin-liquid barium boluses. Three events surrounding bolus movement were tracked via videofluoroscopy, two additional events were found using manometric measures. As the bolus passes through the pharynx, low pressure is created at and below the head of the bolus. A modest pressure increase is seen as the bolus passes through the pharynx and finally, high pressure is observed at the bolus tail, followed by an even larger pressure generation of a clearance event. HRM allows for greater resolution in data collection in the pharynx and in this study, aided in identifying semi unique characteristics around the hypopharynx and the UES which are consistent with the complex anatomy of the regions and the transition of the UES from active closure to relaxed opening. In the future, additional studies designed to look at aged and diseased populations may lead to better understanding of disease etiology, and treatment options. PMID:27565155

  3. Practice Change From Intermittent Medication Boluses to Bolusing From a Continuous Infusion in Pediatric Critical Care: A Quality Improvement Project.

    Science.gov (United States)

    Hochstetler, Jessica L; Thompson, A Jill; Ball, Natalie M; Evans, Melissa C; Frame, Shaun C; Haney, A Lauren; Little, Amelia K; O'Donnell, Jaime L; Rickett, Bryna M; Mack, Elizabeth H

    2018-04-12

    To determine whether implementing a guideline to bolus medications from continuous infusions in PICUs affects nursing satisfaction, patient safety, central line entries, medication utilization, or cost. This is a pre- and postimplementation quality improvement study. An 11-bed ICU and 14-bed cardiac ICU in a university-affiliated children's hospital. Patients less than 18 years old admitted to the PICU or pediatric cardiac ICU receiving a continuous infusion of dexmedetomidine, midazolam, fentanyl, morphine, vecuronium, or cisatracurium from May 2015 to May 2016, excluding November 2015 (washout period), were eligible for inclusion. Change in practice from administering bolus doses from an automated dispensing machine to administering bolus medications from continuous infusion in PICUs. Timing studies were conducted pre- and post implementation in 29 and 26 occurrences, respectively. The median time from the decision to give a bolus until it began infusing decreased by 169 seconds (p 0.05). Annualized cost avoidance was $124,160. Implementation of bolus medications from continuous infusion in PICUs significantly decreased time to begin a bolus dose and increased nursing satisfaction. The practice change also improved medication utilization without negatively impacting patient safety.

  4. Liposomal Bupivacaine Injection Technique in Total Knee Arthroplasty.

    Science.gov (United States)

    Meneghini, R Michael; Bagsby, Deren; Ireland, Philip H; Ziemba-Davis, Mary; Lovro, Luke R

    2017-01-01

    Liposomal bupivacaine has gained popularity for pain control after total knee arthroplasty (TKA), yet its true efficacy remains unproven. We compared the efficacy of two different periarticular injection (PAI) techniques for liposomal bupivacaine with a conventional PAI control group. This retrospective cohort study compared consecutive patients undergoing TKA with a manufacturer-recommended, optimized injection technique for liposomal bupivacaine, a traditional injection technique for liposomal bupivacaine, and a conventional PAI of ropivacaine, morphine, and epinephrine. The optimized technique utilized a smaller gauge needle and more injection sites. Self-reported pain scores, rescue opioids, and side effects were compared. There were 41 patients in the liposomal bupivacaine optimized injection group, 60 in the liposomal bupivacaine traditional injection group, and 184 in the conventional PAI control group. PAI liposomal bupivacaine delivered via manufacturer-recommended technique offered no benefit over PAI ropivacaine, morphine, and epinephrine. Mean pain scores and the proportions reporting no or mild pain, time to first opioid, and amount of opioids consumed were not better with PAI liposomal bupivacaine compared with PAI ropivacaine, morphine, and epinephrine. The use of the manufacturer-recommended technique for PAI of liposomal bupivacaine does not offer benefit over a conventional, less expensive PAI during TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Directory of Open Access Journals (Sweden)

    Shin-Wook Kim

    Full Text Available OBJECTIVE: Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D printer and evaluated its feasibility for radiotherapy. METHODS: We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. RESULTS: The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. CONCLUSIONS: A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  6. A customized bolus produced using a 3-dimensional printer for radiotherapy.

    Science.gov (United States)

    Kim, Shin-Wook; Shin, Hun-Joo; Kay, Chul Seung; Son, Seok Hyun

    2014-01-01

    Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy. We designed two kinds of bolus for production on a 3D printer, one of which was the 3D printed flat bolus for the Blue water phantom and the other was a 3D printed customized bolus for the RANDO phantom. The 3D printed flat bolus was fabricated to verify its physical quality. The resulting 3D printed flat bolus was evaluated by assessing dosimetric parameters such as D1.5 cm, D5 cm, and D10 cm. The 3D printed customized bolus was then fabricated, and its quality and clinical feasibility were evaluated by visual inspection and by assessing dosimetric parameters such as Dmax, Dmin, Dmean, D90%, and V90%. The dosimetric parameters of the resulting 3D printed flat bolus showed that it was a useful dose escalating material, equivalent to a commercially available flat bolus. Analysis of the dosimetric parameters of the 3D printed customized bolus demonstrated that it is provided good dose escalation and good contact with the irregular surface of the RANDO phantom. A customized bolus produced using a 3D printer could potentially replace commercially available flat boluses.

  7. Safe structural food bolus in elderly: the relevant parameters

    OpenAIRE

    Vandenberghe-Descamps, Mathilde; Septier, Chantal; Prot, Aurélie; Tournier, Carole; Hennequin, Martine; Vigneau, Evelyne; Feron, Gilles; Labouré, Hélène

    2017-01-01

    Mastication is essential to prepare food into a bolus ready to be swallowed safely, with no choking risk. Based on food bolus properties, a masticatory normative indicator was developed by Woda et al. (2010) to identify impaired masticatory function within good oral health population. The aim of the present study was to identify relevant parameters of bolus' structure to differentiate safe to unsafe bolus among elderly contrasting by their dental status.93 elderly, 58% with at least 7 posteri...

  8. Plasma free amino acid kinetics in rainbow trout (Oncorhynchus mykiss) using a bolus injection of 15N-labeled amino acids.

    Science.gov (United States)

    Robinson, Jacob William; Yanke, Dan; Mirza, Jeff; Ballantyne, James Stuart

    2011-02-01

    To gain insight into the metabolic design of the amino acid carrier systems in fish, we injected a bolus of (15)N amino acids into the dorsal aorta in mature rainbow trout (Oncorhynchus mykiss). The plasma kinetic parameters including concentration, pool size, rate of disappearance (R(d)), half-life and turnover rate were determined for 15 amino acids. When corrected for metabolic rate, the R(d) values obtained for trout for most amino acids were largely comparable to human values, with the exception of glutamine (which was lower) and threonine (which was higher). R(d) values ranged from 0.9 μmol 100 g(-1) h(-1) (lysine) to 22.1 μmol 100 g(-1) h(-1) (threonine) with most values falling between 2 and 6 μmol 100 g(-1) h(-1). There was a significant correlation between R(d) and the molar proportion of amino acids in rainbow trout whole body protein hydrolysate. Other kinetic parameters did not correlate significantly with whole body amino acid composition. This indicates that an important design feature of the plasma-free amino acids system involves proportional delivery of amino acids to tissues for protein synthesis.

  9. 21 CFR 520.1660c - Oxytetracycline hydrochloride tablets/boluses.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride tablets/boluses. 520....1660c Oxytetracycline hydrochloride tablets/boluses. (a) Specifications. Each tablet or bolus contains 250, 500, or 1,000 milligrams of oxytetracycline hydrochloride. (b) Sponsors. For sponsors in § 510...

  10. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    International Nuclear Information System (INIS)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J

    2015-01-01

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry

  11. SU-C-213-06: Dosimetric Verification of 3D Printed Electron Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, K; Corbett, M; Pelletier, C; Huang, Z; Feng, Y; Jung, J [East Carolina Univ, Greenville, NC (United States)

    2015-06-15

    Purpose: To determine the dosimetric effect of 3D printed bolus in an anthropomorphic phantom. Methods: Conformable bolus material was generated for an anthropomorphic phantom from a DICOM volume. The bolus generated was a uniform expansion of 5mm applied to the nose region of the phantom, as this is a difficult area to uniformly apply bolus clinically. A Printrbot metal 3D Printer using PLA plastic generated the bolus. A 9MeV anterior beam with a 5cm cone was used to deliver dose to the nose of the phantom. TLD measurements were compared to predicted values at the phantom surface. Film planes were analyzed for the printed bolus, a standard 5mm bolus sheet placed on the phantom, and the phantom with no bolus applied to determine depth and dose distributions. Results: TLDs measured within 2.5% of predicted value for the 3D bolus. Film demonstrated a more uniform dose distribution in the nostril region for the 3d printed bolus than the standard bolus. This difference is caused by the air gap created around the nostrils by the standard bolus, creating a secondary build-up region. Both demonstrated a 50% central axis dose shift of 5mm relative to the no bolus film. HU for the bolus calculated the PLA electron density to be ∼1.1g/cc. Physical density was measured to be 1.3g/cc overall. Conclusion: 3D printed PLA bolus demonstrates improved dosimetric performance to standard bolus for electron beams with complex phantom geometry.

  12. Fabrication of malleable three-dimensional-printed customized bolus using three-dimensional scanner.

    Directory of Open Access Journals (Sweden)

    Jae Won Park

    Full Text Available A three-dimensional (3D-printed customized bolus (3D bolus can be used for radiotherapy application to irregular surfaces. However, bolus fabrication based on computed tomography (CT scans is complicated and also delivers unwanted irradiation. Consequently, we fabricated a bolus using a 3D scanner and evaluated its efficacy. The head of an Alderson Rando phantom was scanned with a 3D scanner. The 3D surface data were exported and reconstructed with Geomagic Design X software. A 3D bolus of 5-mm thickness designed to fit onto the nose was printed with the use of rubber-like printing material, and a radiotherapy plan was developed. We successfully fabricated the customized 3D bolus, and further, a CT simulation indicated an acceptable fit of the 3D bolus to the nose. There was no air gap between the bolus and the phantom surface. The percent depth dose (PDD curve of the phantom with the 3D bolus showed an enhanced surface dose when compared with that of the phantom without the bolus. The PDD of the 3D bolus was comparable with that of a commercial superflab bolus. The radiotherapy plan considering the 3D bolus showed improved target coverage when compared with that without the bolus. Thus, we successfully fabricated a customized 3D bolus for an irregular surface using a 3D scanner instead of a CT scanner.

  13. Qualitative indices and enhancement rate of CT pulmonary angiography in patients with suspected pulmonary embolism: Comparison between test bolus and bolus-tracking methods

    Directory of Open Access Journals (Sweden)

    Maryam Moradi

    2016-01-01

    Full Text Available Background: The aim of the present study was to assess the qualitative indices and enhancement rate of computed tomographic pulmonary angiography (CTPA in patients with suspected pulmonary embolism using Test bolus and Bolus-tracking techniques. Materials and Methods: Fifty-two patients with suspected pulmonary embolism that passed informed consent were randomly divided in the two groups. In each group, demographic characteristics, qualitative indices, and enhancement rate of CTPA were recorded. Results: The diagnostic result obtained in majority of the participants in the two groups (88.5 % in Test bolus group vs. 73.1% in the Bolus tracking group. In the case of quantitative variables, no statistically significant differences were found between the groups (P > 0.05. The only statistically significant difference between the two groups is average of "X-ray dose". Conclusion: The results of our study show that there is no statistically significant difference between the Bolus Tracking and Test Bolus techniques for producing more homogeneous enhancement.

  14. The application of DSA bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus

    International Nuclear Information System (INIS)

    Ren Chongyang; Di Zhenhai; Mao Xuequn; Zou Rong; Zhang Jian; Wang Meirong; Li Quan

    2010-01-01

    Objective: To retrospectively evaluate the digital subtraction angiography (DSA) bolus chase technology in diagnosing the vascular disorders of lower extremities due to diabetes mellitus. Methods: From January 2004 to March 2010, DSA was performed in forty-five diabetes patients with suspicious vascular diseases of lower extremities. Among them, 24 cases (31 lower limbs)were examined with DSA bolus chase technology and the remaining 21 cases (21 lower limbs)were examined with traditional segmentational technique. The contrast dosage used in angiography, the total exposure time, the examination time and the imaging value for making diagnosis were analyzed and compared between two techniques. Results: For DSA bolus chase technology group, the contrast dosage used in angiography, the total exposure time and the examination time were 25.26 ml, 13.23 s and 37.26 min, respectively,with an average exposure of 101.65 pictures. For traditional segmentational technique group, the contrast dosage used in angiography, the total exposure time and the examination time were 130.00 ml, 52.38 s and 50.48 min, respectively, with an average exposure of 118.33 pictures. The percentage of high quality images in bolus chase technology group and in traditional segmentational technique group were 90.3% and 90.5%, respectively. All the images could meet the requirements for making a reliable diagnosis. Conclusion: Digital subtraction angiography by using bolus-chase technology can well demonstrate the vascular pathology of lower extremities caused by diabetes mellitus, obtain sufficient imaging information necessary for making a reliable diagnosis. DSA bolus chase technology is superior to traditional segmentational technique in shortening procedure time, reducing contrast medium dosage and decreasing radiation dose. (authors)

  15. Cardiac T1 mapping in congenital heart disease: bolus vs. infusion protocols for measurements of myocardial extracellular volume fraction.

    Science.gov (United States)

    Al-Wakeel-Marquard, Nadya; Rastin, Sanaz; Muench, Frédéric; O H-Ici, Darach; Yilmaz, Sevim; Berger, Felix; Kuehne, Titus; Messroghli, Daniel R

    2017-12-01

    Myocardial extracellular volume fraction (ECV) reflecting diffuse myocardial fibrosis can be measured with T1 mapping cardiovascular magnetic resonance (CMR) before and after the application of a gadolinium-based extracellular contrast agent. The equilibrium between blood and myocardium contrast concentration required for ECV measurements can be obtained with a primed contrast infusion (equilibrium contrast-CMR). We hypothesized that equilibrium can also be achieved with a single contrast bolus to accurately measure diffuse myocardial fibrosis in patients with congenital heart disease (CHD). Healthy controls (n = 17; median age 24.0 years) and patients with CHD (n = 19; 25.0 years) were prospectively enrolled. Using modified Look-Locker inversion recovery T1 mapping before, 15 min after bolus injection, and during constant infusion of gadolinium-DOTA, T1 values were obtained for blood pool and myocardium of the left ventricle (LV), the interventricular septum (IVS), and the right ventricle (RV) in a single midventricular plane in short axis or in transverse orientation. ECV of LV, IVS and RV by bolus-only and bolus-infusion correlated significantly in CHD patients (r = 0.94, 0.95, and 0.74; p < 0.01, respectively) and healthy controls (r = 0.96, 0.89, and 0.64; p < 0.05, respectively). Bland-Altman plots revealed no significant bias between the techniques for any of the analyzed regions. ECV of LV and RV myocardium measured by bolus-only T1 mapping agrees well with bolus-infusion measurements in patients with CHD. The use of a bolus-only approach facilitates the integration of ECV measurements into existing CMR imaging protocols, allowing for assessment of diffuse myocardial fibrosis in CHD in clinical routine.

  16. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

  17. SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Yang, M; Yan, Y; Rahimi, A; Chopra, R; Jiang, S

    2015-01-01

    Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy

  18. Care-bolus tracking systems in multislice-helical computed tomography - a new method in the screening of cardiovascular failure?

    International Nuclear Information System (INIS)

    Stueckle, C.A.; Kickuth, R.; Kirchner, E.M.; Liermann, D.; Kirchner, J.

    2002-01-01

    Purpose. Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function.Material and methods. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. trademark Bolus software. This performs repetitive low- dose test scans (e.g. for the abdomen: 140 kV, 20 mA, TI 0,5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml Iopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements.Results. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus- tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure.Conclusion. The bolus tracking system C.A.R.E.-bolus copyright often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary

  19. Blindness following cosmetic injections of the face.

    Science.gov (United States)

    Lazzeri, Davide; Agostini, Tommaso; Figus, Michele; Nardi, Marco; Pantaloni, Marcello; Lazzeri, Stefano

    2012-04-01

    Complications following facial cosmetic injections have recently heightened awareness of the possibility of iatrogenic blindness. The authors conducted a systematic review of the available literature to provide the best evidence for the prevention and treatment of this serious eye injury. The authors included in the study only the cases in which blindness was a direct consequence of a cosmetic injection procedure of the face. Twenty-nine articles describing 32 patients were identified. In 15 patients, blindness occurred after injections of adipose tissue; in the other 17, it followed injections of various materials, including corticosteroids, paraffin, silicone oil, bovine collagen, polymethylmethacrylate, hyaluronic acid, and calcium hydroxyapatite. Some precautions may minimize the risk of embolization of filler into the ophthalmic artery following facial cosmetic injections. Intravascular placement of the needle or cannula should be demonstrated by aspiration before injection and should be further prevented by application of local vasoconstrictor. Needles, syringes, and cannulas of small size should be preferred to larger ones and be replaced with blunt flexible needles and microcannulas when possible. Low-pressure injections with the release of the least amount of substance possible should be considered safer than bolus injections. The total volume of filler injected during the entire treatment session should be limited, and injections into pretraumatized tissues should be avoided. Actually, no safe, feasible, and reliable treatment exists for iatrogenic retinal embolism. Nonetheless, therapy should theoretically be directed to lowering intraocular pressure to dislodge the embolus into more peripheral vessels of the retinal circulation, increasing retinal perfusion and oxygen delivery to hypoxic tissues. Risk, V.

  20. MR liver imaging after bolus administration of Teslascan

    International Nuclear Information System (INIS)

    Costa, S.; Marti-Bonmati, L.; Delgado, F.; Torregrosa, A.

    2003-01-01

    nature of the lesion, with those containing hepatocytes being enhanced. Most patients exhibited a sensation of hot flashes (28 of 31, 90%) and no discomfort in the area of injection. No other adverse reactions were reported. Bolus administration of Teslascan (∼ 1 ml/s) is safe, effective, and helpful in the detection and characterization of focal lesions. A combination of GE T1 and STIR sequences after contrast administration maximizes the detection of hepatic lesions. Manganese is useful in confirming the hepatocellular origin of both lesions and findings associated with cirrhosis of the liver, which is helpful in classifying the lesions. Lack of contrast enhancement in previously treated CHC patients should be considered evidence of its therapeutic success. (Author) 17 refs

  1. Esophageal Transit, Contraction and Perception of Transit After Swallows of Two Viscous Boluses.

    Science.gov (United States)

    Dalmazo, Jucileia; Aprile, Lilian Rose Otoboni; Dantas, Roberto Oliveira

    2015-10-01

    There have been results showing the influence of bolus viscosities and consistency on esophageal motility and transit. However, there is no description about the influence of two different viscous boluses on esophageal contractions, bolus transit and perception of transit. Our objective in this investigation was to evaluate the esophageal transit and contraction after swallows of two viscous boluses. By impedance and manometric methods, we measured the esophageal transit and contraction after swallows of two viscous boluses of 5 mL volume, 100% barium sulfate and yogurt, swallowed in duplicate in the supine and upright positions. The bolus transit, esophageal contractions and the perception of bolus transit through the esophagus were evaluated in both positions. Impedance and contraction were measured at 5, 10, 15 and 20 cm from the lower esophageal sphincter. After each swallow, the volunteers were asked about the sensation of bolus transit through the esophagus. In supine position, the yogurt had a less frequent complete bolus transit than barium. Also in the supine position, the esophageal transit was longer with yogurt than with barium. Esophageal contractions after swallows were similar between barium and yogurt boluses. There was no difference in perception of transit between the two boluses. Although both 100% barium sulfate and yogurt are viscous boluses and have similar viscosities, the transit through the esophagus is slower with yogurt bolus than with barium bolus, which suggests that viscosity may be not the sole factor to determine transit.

  2. Mapping water exchange rates in rat tumor xenografts using the late-stage uptake following bolus injections of contrast agent.

    Science.gov (United States)

    Bailey, Colleen; Moosvi, Firas; Stanisz, Greg J

    2014-05-01

    To map the intra-to-extracellular water exchange rate constant in rat xenografts using a two-compartment model of relaxation with water exchange and a range of contrast agent concentrations and compare with histology. MDA-MB-231 cells were xenografted into six nude rats. Three bolus injections of gadodiamide were administered. When uptake in the tumor demonstrated a steady-state, T1 data were acquired by spoiled gradient recalled acquisitions at four flip angles. A global fit of data to a two-compartment model incorporating exchange was performed, assuming a distribution volume of 20% of the rat. Voxels that did not reach steady-state and were excluded from parametric maps tended to be in large necrotic areas. TUNEL-negative (nonapoptotic) regions tended to have well-defined error bounds, with an average intra-to-extracellular exchange rate constant of 0.6 s(-1) . Apoptotic regions had higher exchange, but poorly determined upper bounds, with goodness of fit similar to that for a model assuming infinitely fast exchange. A lower bound of >3 s(-1) was used to establish voxels where the exchange rate constant was fast despite a large upper bound. Water exchange rates were higher in apoptotic regions, but examination of statistical errors was an important step in the mapping process. Copyright © 2013 Wiley Periodicals, Inc.

  3. On bolus for megavoltage photon and electron radiation therapy

    International Nuclear Information System (INIS)

    Vyas, Vedang; Palmer, Lisa; Mudge, Ray; Jiang, Runqing; Fleck, Andre; Schaly, Bryan; Osei, Ernest; Charland, Paule

    2013-01-01

    Frequently, in radiation therapy one must treat superficial lesions on cancer patients; these are at or adjacent to the skin. Megavoltage photon radiotherapy penetrates through the skin to irradiate deep-seated tumors, with skin-sparing property. Hence, to treat superficial lesions, one must use a layer of scattering material to feign as the skin surface. Although megavoltage electron beams are used for superficial treatments, one occasionally needs to enhance the dose near the surface. Such is the function of a “bolus,” a natural or synthetically developed material that acts as a layer of tissue to provide a more effective treatment to the superficial lesions. Other uses of boluses are to correct for varying surface contours and to add scattering material around the patient's surface. Materials used as bolus vary from simple water to metal and include various mixtures and compounds. Even with the modernization of the technology for external-beam therapy and the emergence of various commercial boluses, the preparation and utilization of a bolus in clinical radiotherapy remains an art. Considering the varying experiences and practices, this paper briefly summarizes available boluses that have been proposed and are employed in clinical radiotherapy. Although this review is not exhaustive, it provides some initial guidance and answers questions that may arise in clinical practice

  4. Intravenous Tranexamic Acid Bolus plus Infusion Is Not More Effective than a Single Bolus in Primary Hip Arthroplasty: A Randomized Controlled Trial.

    Science.gov (United States)

    Zufferey, Paul J; Lanoiselée, Julien; Chapelle, Céline; Borisov, Dmitry B; Bien, Jean-Yves; Lambert, Pierre; Philippot, Rémi; Molliex, Serge; Delavenne, Xavier

    2017-09-01

    Preoperative administration of the antifibrinolytic agent tranexamic acid reduces bleeding in patients undergoing hip arthroplasty. Increased fibrinolytic activity is maintained throughout the first day postoperation. The objective of the study was to determine whether additional perioperative administration of tranexamic acid would further reduce blood loss. This prospective, double-blind, parallel-arm, randomized, superiority study was conducted in 168 patients undergoing unilateral primary hip arthroplasty. Patients received a preoperative intravenous bolus of 1 g of tranexamic acid followed by a continuous infusion of either tranexamic acid 1 g (bolus-plus-infusion group) or placebo (bolus group) for 8 h. The primary outcome was calculated perioperative blood loss up to day 5. Erythrocyte transfusion was implemented according to a restrictive transfusion trigger strategy. The mean perioperative blood loss was 919 ± 338 ml in the bolus-plus-infusion group (84 patients analyzed) and 888 ± 366 ml in the bolus group (83 patients analyzed); mean difference, 30 ml (95% CI, -77 to 137; P = 0.58). Within 6 weeks postsurgery, three patients in each group (3.6%) underwent erythrocyte transfusion and two patients in the bolus group experienced distal deep-vein thrombosis. A meta-analysis combining data from this study with those of five other trials showed no incremental efficacy of additional perioperative administration of tranexamic acid. A preoperative bolus of tranexamic acid, associated with a restrictive transfusion trigger strategy, resulted in low erythrocyte transfusion rates in patients undergoing hip arthroplasty. Supplementary perioperative administration of tranexamic acid did not achieve any further reduction in blood loss.

  5. Adductor Canal Block With Continuous Infusion Versus Intermittent Boluses and Morphine Consumption

    DEFF Research Database (Denmark)

    Jaeger, Pia; Baggesgaard, Jonas; Sørensen, Johan K

    2018-01-01

    a randomized, blinded, controlled study, including patients scheduled for total knee arthroplasty with spinal anesthesia. Patients received 0.2% ropivacaine via a catheter in the adductor canal administered as either repeated intermittent boluses (21 mL/3 h) or continuous infusion (7 mL/h). The primary outcome...

  6. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Science.gov (United States)

    Peyron, Marie-Agnès; Gierczynski, Isabelle; Hartmann, Christoph; Loret, Chrystel; Dardevet, Dominique; Martin, Nathalie; Woda, Alain

    2011-01-01

    Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. Several physical changes appeared in the food bolus as it was formed during mastication: (1) in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2) by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3) median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4) except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5) physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of swallowing, since they appeared in boluses prepared in various

  7. Role of physical bolus properties as sensory inputs in the trigger of swallowing.

    Directory of Open Access Journals (Sweden)

    Marie-Agnès Peyron

    Full Text Available BACKGROUND: Swallowing is triggered when a food bolus being prepared by mastication has reached a defined state. However, although this view is consensual and well supported, the physical properties of the swallowable bolus have been under-researched. We tested the hypothesis that measuring bolus physical changes during the masticatory sequence to deglutition would reveal the bolus properties potentially involved in swallowing initiation. METHODS: Twenty normo-dentate young adults were instructed to chew portions of cereal and spit out the boluses at different times in the masticatory sequence. The mechanical properties of the collected boluses were measured by a texture profile analysis test currently used in food science. The median particle size of the boluses was evaluated by sieving. In a simultaneous sensory study, twenty-five other subjects expressed their perception of bolus texture dominating at any mastication time. FINDINGS: Several physical changes appeared in the food bolus as it was formed during mastication: (1 in rheological terms, bolus hardness rapidly decreased as the masticatory sequence progressed, (2 by contrast, adhesiveness, springiness and cohesiveness regularly increased until the time of swallowing, (3 median particle size, indicating the bolus particle size distribution, decreased mostly during the first third of the masticatory sequence, (4 except for hardness, the rheological changes still appeared in the boluses collected just before swallowing, and (5 physical changes occurred, with sensory stickiness being described by the subjects as a dominant perception of the bolus at the end of mastication. CONCLUSIONS: Although these physical and sensory changes progressed in the course of mastication, those observed just before swallowing seem to be involved in swallowing initiation. They can be considered as strong candidates for sensory inputs from the bolus that are probably crucially involved in the triggering of

  8. A Study on the Necessary Number of Bolus Treatments in Radiotherapy after Modified Radical Mastectomy

    International Nuclear Information System (INIS)

    Hong, Chae Seon; Kim, Jong Sik; Kim, Young Kon; Park, Young Hwan

    2006-01-01

    Post-mastectomy radiotherapy (PMR) is known to decrease loco-regional recurrence. Adequate skin and dermal dose are achieved by adding bolus. The more difficult clinical issue is determining the necessary number of bolus treatment, given the limits of normal skin tolerance. The aim of this study is to evaluate the necessary number of bolus treatment after PMR in patients with breast cancer. Four female breast cancer patients were included in the study. The median age was 53 years(range, 38-74), tumor were left sided in 2 patients and right sided in 2 patients. All patients were treated with postoperative radiotherapy after MRM. Radiotherapy was delivered to the chest wall (C.W) and supraclavicular lymph nodes (SCL) using 4 MV X-ray. The total dose was 50 Gy, in 2 Gy fractions (with 5 times a week). CT was performed for treatment planning, treatment planning was performed using A DAC-Pinnacles 3 (Phillips, USA) for all patients without and with bolus. Bolus treatment plans were generated using image tool (0.5 cm of thickness and 6 cm of width). Dose distribution was analyzed and the increased skin dose rate in the build-up region was computed and the skin dose using TLD-100 chips (Harshaw, USA) was measured. No significant difference was found in dose distribution without and with bolus; C.W coverage was 95-100% of the prescribed dose in both. But, there was remarkable difference in the skin dose to the scar. The skin dose to the scar without and with bolus were 100-105% and 50-75%. The increased skin dose rates in the build-up region for Pt. 1, Pt. 2. Pt. 3 and Pt. 4 were 23.3%, 35.6%, 34.9%, and 41.7%. The results of measured skin dose using TLD-100 chips in the cases without and with bolus were 209.3 cGy and 161.1 cGy, 200 cGy and 150.2 cGy, 211.4 cGy and 160.5 cGy, 198.6 cGy and 155.5 cGy for Pt. 1, Pt. 2, Pt. 3, and Pt. 4. It was concludes through this analysis that the adequate number of bolus treatments is 50-60% of the treatment program. Further, clinical

  9. Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy

    International Nuclear Information System (INIS)

    Kavanaugh, James A.; Hogstrom, Kenneth R.; Fontenot, Jonas P.; Henkelmann, Gregory; Chu, Connel; Carver, Robert A.

    2013-01-01

    Purpose: The purpose of this study was to demonstrate that a bolus electron conformal therapy (ECT) dose plan and a mixed beam plan, composed of an intensity modulated x-ray therapy (IMXT) dose plan optimized on top of the bolus ECT plan, can be accurately delivered. Methods: Calculated dose distributions were compared with measured dose distributions for parotid and chest wall (CW) bolus ECT and mixed beam plans, each simulated in a cylindrical polystyrene phantom that allowed film dose measurements. Bolus ECT plans were created for both parotid and CW PTVs (planning target volumes) using 20 and 16 MeV beams, respectively, whose 90% dose surface conformed to the PTV. Mixed beam plans consisted of an IMXT dose plan optimized on top of the bolus ECT dose plan. The bolus ECT, IMXT, and mixed beam dose distributions were measured using radiographic films in five transverse and one sagittal planes for a total of 36 measurement conditions. Corrections for film dose response, effects of edge-on photon irradiation, and effects of irregular phantom optical properties on the Cerenkov component of the film signal resulted in high precision measurements. Data set consistency was verified by agreement of depth dose at the intersections of the sagittal plane with the five measured transverse planes. For these same depth doses, results for the mixed beam plan agreed with the sum of the individual depth doses for the bolus ECT and IMXT plans. The six mean measured planar dose distributions were compared with those calculated by the treatment planning system for all modalities. Dose agreement was assessed using the 4% dose difference and 0.2 cm distance to agreement. Results: For the combined high-dose region and low-dose region, pass rates for the parotid and CW plans were 98.7% and 96.2%, respectively, for the bolus ECT plans and 97.9% and 97.4%, respectively, for the mixed beam plans. For the high-dose gradient region, pass rates for the parotid and CW plans were 93.1% and 94

  10. Feasibility of test-bolus DCE-MRI using CAIPIRINHA-VIBE for the evaluation of pancreatic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Jimi; Seo, Nieun; Kim, Bohyun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Choi, Yoonseok; Woo, Dong-Cheol; Lee, Chang Kyung [Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of); Kim, In Seong [Siemens Healthcare, Seoul (Korea, Republic of); Nickel, Dominik [Siemens Healthcare, Erlangen (Germany); Kim, Kyung Won [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul (Korea, Republic of); Asan Medical Center, Bioimaging Center, Asan Institute for Life Sciences, Seoul (Korea, Republic of)

    2016-11-15

    To evaluate the feasibility of test-bolus dynamic contrast-enhanced (DCE) MRI with CAIPIRINHA-VIBE for pancreatic malignancies. Thirty-two patients underwent DCE-MRI with CAIPIRINHA-VIBE after injection of 2 mL gadolinium. From the resulting time-intensity curve (TIC), we estimated the arterial (AP) and portal venous phase (PVP) scan timing for subsequent multiphasic MRI. DCE-MRI perfusion maps were generated, and perfusion parameters were calculated. The image quality was rated on a 5-point scale (1: poor, 5: excellent). Goodness-of-fit of the TIC was evaluated by Pearson's χ{sup 2} test. Test-bolus DCE-MRIs with high temporal (3 s) and spatial resolution (1 x 1 x 4 mm{sup 3}) were acquired with good-quality perfusion maps of Ktrans and iAUC (mean score 4.313 ± 0.535 and 4.125 ± 0.554, respectively). The mean χ{sup 2} values for fitted TICs were 0.115 ± 0.082 for the pancreatic parenchyma and 0.784 ± 0.074 for pancreatic malignancies, indicating an acceptable goodness-of-fit. Test-bolus DCE-MRI was highly accurate in estimating the proper timing of AP (90.6 %) and PVP (100 %) of subsequent multiphasic MRI. Between pancreatic adenocarcinomas and neuroendocrine tumours, there were significant differences in the Ktrans (0.073 ± 0.058 vs. 0.308 ± 0.062, respectively; p = 0.007) and iAUC (1.501 ± 0.828 vs. 3.378 ± 0.378, respectively; p = 0.045). Test-bolus DCE-MRI using CAIPIRINHA-VIBE is feasible for incorporating perfusion analysis of pancreatic tumours into routine multiphasic MRI. (orig.)

  11. Ultrasound and Histologic Examination after Subcutaneous Injection of Two Volumizing Hyaluronic Acid Fillers: A Preliminary Study

    Science.gov (United States)

    Besse, Stéphanie; Sarazin, Didier; Quinodoz, Pierre; Elias, Badwi; Safa, Marva; Vandeputte, Joan

    2017-01-01

    Background: This study examined the influence of hyaluronic acid (HA) crosslinking technology on the ultrasound and histologic behavior of HA fillers designed for subcutaneous injection. Methods: One subject received subcutaneous injections of 0.25 ml Cohesive Polydensified Matrix (CPM) and Vycross volumizing HA in tissue scheduled for abdominoplasty by bolus and retrograde fanning techniques. Ultrasound analyses were performed on days 0 and 8 and histologic analyses on days 0 and 21 after injection. A series of simple rheologic tests was also performed. Results: Day 0 ultrasound images after bolus injection showed CPM and Vycross as hypoechogenic papules in the hypodermis. CPM appeared little changed after gentle massage, whereas Vycross appeared more hyperechogenic and diminished in size. Ultrasound images at day 8 were similar. On day 0, both gels appeared less hypoechogenic after retrograde fanning than after bolus injection. Vycross was interspersed with hyperechogenic areas (fibrous septa from the fat network structure) and unlike CPM became almost completely invisible after gentle massage. On day 8, CPM appeared as a hypoechogenic pool and Vycross as a long, thin rod. Day 0 histologic findings confirmed ultrasound results. Day 21 CPM histologic findings showed a discrete inflammatory reaction along the injection row after retrograde fanning. Vycross had a more pronounced inflammatory reaction, particularly after retrograde fanning, with macrophages and giant cells surrounding the implant. Rheologic tests showed CPM to have greater cohesivity and resistance to traction forces than Vycross. Conclusions: CPM HA volumizer appears to maintain greater tissue integrity than Vycross after subcutaneous injection with less inflammatory activity. PMID:28280664

  12. Bolus obstruction by Ascaris lumbricoides | Wynne | South African ...

    African Journals Online (AJOL)

    Bolus obstruction by Ascaris lumbricoides. J.M. Wynne, B.A.H. Ellman. Abstract. Seventy-three cases of obstruction due to a bolus of Ascaris worms are reviewed, The diagnosis was made on the basis either of a characteristic palpable mass or a characteristic radiographic appearance. In 67 cases conservative treatment ...

  13. Solid bolus swallowing in the radiologic evaluation of dysphagia

    International Nuclear Information System (INIS)

    Westen, D. van; Ekberg, O.

    1993-01-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.)

  14. Solid bolus swallowing in the radiologic evaluation of dysphagia

    Energy Technology Data Exchange (ETDEWEB)

    Westen, D. van (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden)); Ekberg, O. (Dept. of Diagnostic Radiology, Malmoe General Hospital, Univ. Lund (Sweden))

    1993-07-01

    Patients with dysphagia, heartburn and chest pain are regularly referred for radiologic evaluation of swallowing. The liquid barium swallow has been of great value for the biphasic evaluation of the pharynx and esophagus. Though many patients complain of dysphagia specifically for solids, solid bolus swallow is ususally not part of the evaluation. For the present study we therefore included the use of a solid bolus with a diameter of 13 mm and interviewed the patients carefully for any symptoms during this tablet swallow. Of 200 patients examined, the tablet passed through the esophagus without delay in 102. In the 98 patients with delayed passage, the solid bolus arrest occurred in the pharynx in 5 and in the esophagus in 93. Arrest in the esophagus was due to esophageal dysmotility in 48 patients. Twenty of these were symptomatic during the tablet swallow. A narrowing was the cause in 45, of whom 9 had symptoms. In 18 patients (9%) the solid bolus added key information to the radiologic evaluation. We therefore recommend that the solid bolus is included in the routine radiologic work-up of patients with dysphagia. Careful attention to symptoms during the tablet swallow is important. (orig.).

  15. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  16. Safety and efficacy of Bolus administration of magnesium sulphate ...

    African Journals Online (AJOL)

    Safety and efficacy of Bolus administration of magnesium sulphate for preeclampsia. ... On-going research is addressing its administration in terms of dosage, duration and safety. Objective: We evaluated a ... Keywords: safety, efficacy, bolus magnesium sulphate, preeclampsia, University of Benin Teaching Hospital

  17. Effects of advanced carbohydrate counting guided by an automated bolus calculator in Type 1 diabetes mellitus (StenoABC)

    DEFF Research Database (Denmark)

    Hommel, E; Schmidt, S; Vistisen, D

    2017-01-01

    -centre, investigator-initiated clinical study. We enrolled advanced carbohydrate counting-naïve adults with Type 1 diabetes and HbA1c levels 64-100 mmol/mol (8.0-11.3%), who were receiving multiple daily insulin injection therapy. In a 1:1-ratio, participants were randomized to receive training in either advanced......AIMS: To test whether concomitant use of an automated bolus calculator for people with Type 1 diabetes carrying out advanced carbohydrate counting would induce further improvements in metabolic control. METHODS: We conducted a 12-month, randomized, parallel-group, open-label, single...... carbohydrate counting using mental calculations (MC group) or advanced carbohydrate counting using an automated bolus calculator (ABC group) during a 3.5-h group training course. For 12 months after training, participants attended a specialized diabetes centre quarterly. The primary outcome was change in HbA1c...

  18. Comparison of Insulin Detemir and Insulin Glargine for Hospitalized Patients on a Basal-Bolus Protocol

    Directory of Open Access Journals (Sweden)

    Sondra Davis

    2017-04-01

    Full Text Available BACKGROUND: The primary purpose of this study is to determine whether insulin detemir is equivalent to insulin glargine in controlling hyperglycemia for the adult hospitalized patient on a basal-bolus treatment regimen. METHODS: A retrospective study was conducted at two acute care hospitals within the same health system. Patients from both facilities who were initiated on a basal-bolus subcutaneous insulin regimen were included in the study. The basal-bolus regimen consisted of three components: basal, bolus, and corrective insulin with only the data from the first seven days analyzed. Once the basal-bolus protocol was initiated, all previous glycemic agents were discontinued. The target glycemic goal of the study was 100–180 mg/dL. RESULTS: In both groups, 50% of the patients had achieved the target glycemic control goal (100–180 mg/dL by day 2 (p = 0.3. However, on the seventh or last day of basal-bolus treatment, whichever came first, 36.36% of patients receiving insulin detemir (n = 88 achieved the blood glucose reading goal compared to 52.00% in patients receiving insulin glargine (n = 100 (p = 0.03. This corresponded to an adjusted odds ratio of 2.12 (1.08 to 4.15, p = 0.03. The adjusting variables were provider type, whether the patient was hospitalized within 30 days prior and diagnosis of stroke. The mean blood glucose readings for the insulin glargine and the insulin detemir groups while on basal-bolus therapy were 200 mg/dL and 215 mg/dL, respectively (p = 0.05. The total number of blood glucose readings less than 70 mg/dL and less than 45 mg/dL was very low and there were no differences in number of episodes with hypoglycemia between the two groups. CONCLUSION: There was not a statistical difference between the two groups at 2 days, however there was on the seventh day or the last day of basal-bolus treatment. There were nonsignificant hypoglycemia events between basal insulin groups and the results for the last or seventh day

  19. Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis

    NARCIS (Netherlands)

    Beenen, Ludo F. M.; Sierink, Joanne C.; Kolkman, Saskia; Nio, C. Yung; Saltzherr, Teun Peter; Dijkgraaf, Marcel G. W.; Goslings, J. Carel

    2015-01-01

    For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this

  20. Cerebral hemodynamic changes measured by gradient-echo or spin-echo bolus tracking and its correlation to changes in ICA blood flow measured by phase-mapping MRI

    DEFF Research Database (Denmark)

    Marstrand, J.R.; Rostrup, Egill; Garde, Ellen

    2001-01-01

    Changes in cerebral blood flow (CBF) induced by Acetazolamide (ACZ) were measured using dynamic susceptibility contrast MRI (DSC-MRI) with both spin echo (SE) EPI and gradient echo (GE) EPI, and related to changes in internal carotid artery (ICA) flow measured by phase-mapping. Also examined...... was the effect of repeated bolus injections. CBF, cerebral blood volume (CBV), and mean transit time (MTT) were calculated by singular value decomposition (SVD) and by deconvolution using an exponential function as kernel. The results showed no dependency on calculation method. GE-EPI measured a significant...... increase in CBF and CBV in response to ACZ, while SE-EPI measured a significant increase in CBV and MTT. CBV and MTT change measured by SE-EPI was sensitive to previous bolus injections. There was a significant linear relation between change in CBF measured by GE-EPI and change in ICA flow. In conclusion...

  1. [Observing the density increase curve after intravenous contrast medium administration using a bolus triggering system: a method for detection cardiovascular disorders?].

    Science.gov (United States)

    Stückle, C A; Kickuth, R; Kirchner, E M; Liermann, D; Kirchner, J

    2002-06-01

    Recently bolus tracking systems were developed to improve the timing of intravenous contrast media application in helical computed tomography. We investigated the benefit of this new method as a parameter of the cardiac function. Retrospective analysis of 64 patients which incidentally underwent bolus triggered contrast enhanced helical CT and invasive investigation of the heart within one week. All examinations were performed on the CT scanner Somatom Plus 4 Volume Zoom (Siemens Corp., Forchheim, Germany) using the C.A.R.E. Bolus software. This performs repetitive low-dose test scans (e.g. for the abdomen: 140 kV, 20 mA, Tl 0.5 s) and measures the Hounsfield attenuation (increase over the baseline) in a preselected region of interest. The displayed increase of vascular density over the time after peripheral contrast media injection (75 ml lopromid (300 mg/ml), 2 ml/s) was categorised to three types: (a) rapid increase, (b) deceleration before a 100 HE threshold was reached and (c) one or more peaks. The findings of the invasive investigation of the heart were correlated to the findings of the bolus-tracking measurements. The examinations were categorized as follows: 19 type A, 34 type B, 11 type C. We found a high significant correlation between the type of the Hounsfield attenuation and systolic pressure in the left ventricle. There was no correlation between the type of the Hounsfield attenuation and the diastolic pressure in the left ventricle, the pressures related to the right ventricle or the ejection fraction. The bolus-tacking system showed a sensitivity of 53, a specificity of 82, an accuracy of 70%, a positive predictive value of 70% and a negative predictive value of 70% in detection of left heart failure. The bolus tracking system C.A.R.E.-bolus often shows atypical Hounsfield attenuation in cases of cardiac failure but is not suitable as a screening method of the cardiopulmonary function.

  2. The comparison of bolus tracking and test bolus techniques for computed tomography thoracic angiography in healthy beagles

    Directory of Open Access Journals (Sweden)

    Nicolette Cassel

    2013-05-01

    Full Text Available Computed tomography thoracic angiography studies were performed on five adult beagles using the bolus tracking (BT technique and the test bolus (TB technique, which were performed at least two weeks apart. For the BT technique, 2 mL/kg of 300 mgI/mL iodinated contrast agent was injected intravenously. Scans were initiated when the contrast in the aorta reached 150 Hounsfield units (HU. For the TB technique, the dogs received a test dose of 15% of 2 mL/kg of 300 mgI/mL iodinated contrast agent, followed by a series of low dose sequential scans. The full dose of the contrast agent was then administered and the scans were conducted at optimal times as identified from time attenuation curves. Mean attenuation in HU was measured in the aorta (Ao and right caudal pulmonary artery (rCPA. Additional observations included the study duration, milliAmpere (mA, computed tomography dose index volume (CTDI[vol] and dose length product (DLP. The attenuation in the Ao (BT = 660 52 HU ± 138 49 HU, TB = 469 82 HU ± 199 52 HU, p = 0.13 and in the rCPA (BT = 606 34 HU ± 143 37 HU, TB = 413 72 HU ± 174.99 HU, p = 0.28 did not differ significantly between the two techniques. The BT technique was conducted in a significantly shorter time period than the TB technique (p = 0.03. The mean mA for the BT technique was significantly lower than the TB technique (p = 0.03, as was the mean CTDI(vol (p = 0.001. The mean DLP did not differ significantly between the two techniques (p = 0.17. No preference was given to either technique when evaluating the Ao or rCPA but the BT technique was shown to be shorter in duration and resulted in less DLP than the TB technique.

  3. Optimization of a beam shaping bolus for superficial microwave hyperthermia waveguide applicators using a finite element method

    International Nuclear Information System (INIS)

    Kumaradas, J Carl; Sherar, Michael D

    2003-01-01

    Temperature inhomogeneity in hyperthermia treatments often limits the total thermal dose that can be delivered to the tumour region. To reduce such inhomogeneities, a prototype dynamically modifiable square array of saline-filled patches which attenuate microwave energy was developed for superficial treatments that use external microwave applicators. The array was situated inside the coupling water bolus that is often used with external applicators. The prototype has been previously tested clinically with promising results. A more complete theoretical analysis of the performance of this new bolus design and improvements to its design by modelling are presented here. The analysis was performed by performing five iterative simulations of the SAR pattern produced inside a tissue structure by a waveguide applicator with a water bolus containing the dynamic patch array attached. Between iterations the patch array configuration was modified in an attempt to improve the ability of the bolus to confine heating to an 'L'-shaped tumour region. These simulations were performed using the finite element method. The steady-state temperature profile was then computed using a finite element method based simulation of heat transfer that assumed a given applicator power level and water bolus temperature. Several iterations of these heat transfer simulations were performed with varying applicator power level and water bolus temperature to improve the confinement of heating to the target region. The analysis showed that the dynamic patch array should be capable of conforming heating to an 'L'-shaped target tumour region while limiting the heating to the surrounding normal tissue to an acceptable level

  4. Bolus obstruction by Ascaris lumbricoides

    African Journals Online (AJOL)

    In 67 cases conservative treatment was successful. ... bolus of worms, biliary ascariasis,3.6 pancreatitis and acute ... or chronic granulomatous peritonitis is rare.i These complica- ... obstruction admitted to the paediatric surgical wards of the.

  5. Green Tea Increases the Concentration of Total Mercury in the Blood of Rats following an Oral Fish Tissue Bolus

    Directory of Open Access Journals (Sweden)

    Elsa M. Janle

    2015-01-01

    Full Text Available Fish has many health benefits but is also the most common source of methylmercury. The bioavailability of methylmercury in fish may be affected by other meal components. In this study, the effect of green tea on the bioavailability of methylmercury from an oral bolus of fish muscle tissue was studied in rats and compared to a water treated control group and a group treated with meso-2,3-dimercaptosuccinic acid (DMSA, a compound used medically to chelate mercury. Rats were given a single oral dose of fish tissue via gavage and one of the treatments. Rats were given access to food for 3 h at 12 h intervals. They were dosed with each of the treatments with each meal. Blood samples were collected for 95 hours. Green tea significantly increased the concentration of total mercury in blood relative to the control, whereas DMSA significantly decreased it. In addition, feeding caused a slight increase in blood mercury for several meals following the initial dose.

  6. The predictive ability of six pharmacokinetic models of rocuronium developed using a single bolus: evaluation with bolus and continuous infusion regimen.

    Science.gov (United States)

    Sasakawa, Tomoki; Masui, Kenichi; Kazama, Tomiei; Iwasaki, Hiroshi

    2016-08-01

    Rocuronium concentration prediction using pharmacokinetic (PK) models would be useful for controlling rocuronium effects because neuromuscular monitoring throughout anesthesia can be difficult. This study assessed whether six different compartmental PK models developed from data obtained after bolus administration only could predict the measured plasma concentration (Cp) values of rocuronium delivered by bolus followed by continuous infusion. Rocuronium Cp values from 19 healthy subjects who received a bolus dose followed by continuous infusion in a phase III multicenter trial in Japan were used retrospectively as evaluation datasets. Six different compartmental PK models of rocuronium were used to simulate rocuronium Cp time course values, which were compared with measured Cp values. Prediction error (PE) derivatives of median absolute PE (MDAPE), median PE (MDPE), wobble, divergence absolute PE, and divergence PE were used to assess inaccuracy, bias, intra-individual variability, and time-related trends in APE and PE values. MDAPE and MDPE values were acceptable only for the Magorian and Kleijn models. The divergence PE value for the Kleijn model was lower than -10 %/h, indicating unstable prediction over time. The Szenohradszky model had the lowest divergence PE (-2.7 %/h) and wobble (5.4 %) values with negative bias (MDPE = -25.9 %). These three models were developed using the mixed-effects modeling approach. The Magorian model showed the best PE derivatives among the models assessed. A PK model developed from data obtained after single-bolus dosing can predict Cp values during bolus and continuous infusion. Thus, a mixed-effects modeling approach may be preferable in extrapolating such data.

  7. The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial.

    Science.gov (United States)

    Karády, Júlia; Panajotu, Alexisz; Kolossváry, Márton; Szilveszter, Bálint; Jermendy, Ádám L; Bartykowszki, Andrea; Károlyi, Mihály; Celeng, Csilla; Merkely, Béla; Maurovich-Horvat, Pál

    2017-11-01

    Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA. Patients referred to coronary CTA due to suspected coronary artery disease were included in the study. All patients received 400 mg/ml iomeprol CM injected with dual-syringe automated injector. Patients were randomized into a three-phasic injection-protocol group, with a CM bolus of 85 ml followed by 40 ml of 75%:25% saline/CM mixture and 30 ml saline chaser bolus; and a four-phasic injection-protocol group, with a saline pacer bolus of 10 ml injected at a lower flow rate before the three-phasic protocol. 2,445 consecutive patients were enrolled (mean age 60.6 ± 12.1 years; females 43.6%). Overall rate of extravasation was 0.9% (23/2,445): 1.4% (17/1,229) in the three-phasic group and 0.5% (6/1,216) in the four-phasic group (p = 0.034). Four-phasic CM administration protocol is easy to implement in the clinical routine at no extra cost. The extravasation rate is reduced by 65% with the application of the four-phasic protocol compared to the three-phasic protocol in coronary CTA. • Four-phasic CM injection-protocol reduces extravasation rate by 65% compared to three-phasic. • The saline pacer bolus substantially reduces the risk of CM extravasation. • The implementation of four-phasic injection-protocol is at no cost.

  8. Enteral nutrition for preterm infants: by bolus or continuous? An update

    Directory of Open Access Journals (Sweden)

    Valentina Bozzetti

    2017-06-01

    Full Text Available Optimization of nutritional management of preterm infants is crucial for achievement of their long-term health. Enteral nutrition is preferred to total parenteral nutrition (TPN because the former avoids complications related to vascular catheterization, sepsis, adverse effects of TPN, and fasting. Due to the lack of ability of preterm infants to coordinate suckling, swallowing, and breathing, tube feeding is necessary for most infants less than 1500 g to ensure sufficient feeding tolerance, to support optimal growth and to reduce the risk of aspiration. Therefore, feeding by orogastric or nasogastric tube using either continuous or intermittent bolus delivery of formula or human milk is common practice for these infants. Theoretical risks and benefits of both continuous nasogastric milk feeding and intermittent bolus milk feeding have been proposed. According to the literature, continuous nutrition could be preferred in smaller infants (as those with a birthweight below 1250 g or hemodynamically impaired infants; in stable growing infants nutrition can be administered intermittently as in healthy term infants.

  9. Effects of copper oxide wire particle bolus therapy on trichostrongyle fecal egg counts in exotic artiodactylids.

    Science.gov (United States)

    Fontenot, Deidre K; Kinney-Moscona, Allyson; Kaplan, Ray M; Miller, James

    2008-12-01

    Four species of artiodactylids (scimitar-horned oryx [Oryx dama]), roan antelope [Hippotragus equinus], blackbuck [Antilope cervicapra]), and blesbok [Damaliscus pygargus phillipsi]) totaling 13 animals were treated with a one-time 12.5-g dose of copper oxide wire particles (COWPs) in a bolus form. Pretreatment, individual trichostrongyle fecal egg counts (FECs) were performed using the McMaster technique. Individual posttreatment FECs were performed every 7 days for 35 days beginning 7 days after bolus administration, and FEC reduction ratios (FECRRs) expressed as percentage reductions from pretreatment values were calculated every 7 days. Mean FECRRs for the 13 animals were 93% +/- 16%, 98% +/- 7%, 91% +/- 28%, 94% +/- 16%, and 90% +/- 13% at 7, 14, 21, 28, and 35 days posttreatment, respectively. These data demonstrate that COWPs in a bolus form were an effective method for reducing FEC in exotic artiodactylids. Based on this limited data, COWPs show promise as an anthelmintic alternative for exotic artiodactylids in zoologic collections.

  10. Computer simulations suggest that acute correction of hyperglycaemia with an insulin bolus protocol might be useful in brain FDG PET

    Energy Technology Data Exchange (ETDEWEB)

    Buchert, R.; Brenner, W.; Apostolova, I.; Mester, J.; Clausen, M. [University Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Santer, R. [University Medical Center Hamburg-Eppendorf (Germany). Center for Gynaecology, Obstetrics and Paediatrics; Silverman, D.H.S. [David Geffen School of Medicine at UCLA, Los Angeles, CA (United States). Dept. of Molecular and Medical Pharmacology

    2009-07-01

    FDG PET in hyperglycaemic subjects often suffers from limited statistical image quality, which may hamper visual and quantitative evaluation. In our study the following insulin bolus protocol is proposed for acute correction of hyperglycaemia (> 7.0 mmol/l) in brain FDG PET. (i) Intravenous bolus injection of short-acting insulin, one I.E. for each 0.6 mmol/l blood glucose above 7.0. (ii) If 20 min after insulin administration plasma glucose is {<=} 7.0 mmol/l, proceed to (iii). If insulin has not taken sufficient effect step back to (i). Compute insulin dose with the updated blood glucose level. (iii) Wait further 20 min before injection of FDG. (iv) Continuous supervision of the patient during the whole scanning procedure. The potential of this protocol for improvement of image quality in brain FDG PET in hyperglycaemic subjects was evaluated by computer simulations within the Sokoloff model. A plausibility check of the prediction of the computer simulations on the magnitude of the effect that might be achieved by correction of hyperglycaemia was performed by retrospective evaluation of the relation between blood glucose level and brain FDG uptake in 89 subjects in whom FDG PET had been performed for diagnosis of Alzheimer's disease. The computer simulations suggested that acute correction of hyperglycaemia according to the proposed bolus insulin protocol might increase the FDG uptake of the brain by up to 80%. The magnitude of this effect was confirmed by the patient data. The proposed management protocol for acute correction of hyperglycaemia with insulin has the potential to significantly improve the statistical quality of brain FDG PET images. This should be confirmed in a prospective study in patients. (orig.)

  11. Computer simulations suggest that acute correction of hyperglycaemia with an insulin bolus protocol might be useful in brain FDG PET

    International Nuclear Information System (INIS)

    Buchert, R.; Brenner, W.; Apostolova, I.; Mester, J.; Clausen, M.; Santer, R.; Silverman, D.H.S.

    2009-01-01

    FDG PET in hyperglycaemic subjects often suffers from limited statistical image quality, which may hamper visual and quantitative evaluation. In our study the following insulin bolus protocol is proposed for acute correction of hyperglycaemia (> 7.0 mmol/l) in brain FDG PET. (i) Intravenous bolus injection of short-acting insulin, one I.E. for each 0.6 mmol/l blood glucose above 7.0. (ii) If 20 min after insulin administration plasma glucose is ≤ 7.0 mmol/l, proceed to (iii). If insulin has not taken sufficient effect step back to (i). Compute insulin dose with the updated blood glucose level. (iii) Wait further 20 min before injection of FDG. (iv) Continuous supervision of the patient during the whole scanning procedure. The potential of this protocol for improvement of image quality in brain FDG PET in hyperglycaemic subjects was evaluated by computer simulations within the Sokoloff model. A plausibility check of the prediction of the computer simulations on the magnitude of the effect that might be achieved by correction of hyperglycaemia was performed by retrospective evaluation of the relation between blood glucose level and brain FDG uptake in 89 subjects in whom FDG PET had been performed for diagnosis of Alzheimer's disease. The computer simulations suggested that acute correction of hyperglycaemia according to the proposed bolus insulin protocol might increase the FDG uptake of the brain by up to 80%. The magnitude of this effect was confirmed by the patient data. The proposed management protocol for acute correction of hyperglycaemia with insulin has the potential to significantly improve the statistical quality of brain FDG PET images. This should be confirmed in a prospective study in patients. (orig.)

  12. An Adaptive Nonlinear Basal-Bolus Calculator for Patients With Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Nørgaard, Kirsten

    2017-01-01

    size. Following meal announcements, the meal compartment and the meal time constant are estimated, otherwise insulin sensitivity is estimated. Results : We compare the performance of a conventional linear bolus calculator with the proposed bolus calculator. The proposed basal-bolus calculator......Background : Bolus calculators help patients with type 1 diabetes to mitigate the effect of meals on their blood glucose by administering a large amount of insulin at mealtime. Intraindividual changes in patients physiology and nonlinearity in insulin-glucose dynamics pose a challenge...... glucose monitor (CGM). The basal rate is determined by calculating the steady state of the model and is adjusted once a day before breakfast. The bolus size is determined by optimizing the postprandial glucose values based on an estimate of the insulin sensitivity and states, as well as the announced meal...

  13. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P. (Aarhus Kommunehospital (Denmark). GI Motility Lab. Aarhus Kommunehospital (Denmark). Dept. of Diagnostic Radiology R)

    1992-02-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P<0.02). GER, grade II (reflux above the level of the carina), occurred equally often as a result of both types of bolus, however. The study suggests that significant, food-stimulated GER is independent of the consistency of the foodstuffs and may be detected employing a liquid bolus. This result might be used in the examination of infants for GER, using milk as a food stimulus. (orig.).

  14. The influence of a solid and liquid bolus on food-stimulated gastroesophageal reflux

    International Nuclear Information System (INIS)

    Naeser, A.; Behrens, J.K.; Vejen-Christiansen, L.; Funch-Jensen, P.; Thommesen, P.; Aarhus Kommunehospital

    1992-01-01

    Using a radiological method to demonstrate food-stimulated gastroesophageal reflux (GER), a comparative study was carried out employing a solid, already validated bolus versus a liquid one. One hundred and four consecutive patients received both a solid and a liquid bolus in randomized order. GER was observed in 37 (35.6%) patients receiving the solid bolus versus 28 (26.9%) with the liquid one. This means that the solid bolus provokes significantly more reflux (P [de

  15. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    International Nuclear Information System (INIS)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M; Fisher, T

    2014-01-01

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice

  16. MO-H-19A-03: Patient Specific Bolus with 3D Printing Technology for Electron Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zou, W; Swann, B; Siderits, R; McKenna, M; Khan, A; Yue, N; Zhang, M [Rutgers University, New Brunswick, NJ (United States); Fisher, T [Memorial Medical Center, Modesto, CA (United States)

    2014-06-15

    Purpose: Bolus is widely used in electron radiotherapy to achieve desired dose distribution. 3D printing technologies provide clinicians with easy access to fabricate patient specific bolus accommodating patient body surface irregularities and tissue inhomogeneity. This study presents the design and the clinical workflow of 3D printed bolus for patient electron therapy in our clinic. Methods: Patient simulation CT images free of bolus were exported from treatment planning system (TPS) to an in-house developed software package. Bolus with known material properties was designed in the software package and then exported back to the TPS as a structure. Dose calculation was carried out to examine the coverage of the target. After satisfying dose distribution was achieved, the bolus structure was transferred in Standard Tessellation Language (STL) file format for the 3D printer to generate the machine codes for printing. Upon receiving printed bolus, a quick quality assurance was performed with patient resimulated with bolus in place to verify the bolus dosimetric property before treatment started. Results: A patient specific bolus for electron radiotherapy was designed and fabricated in Form 1 3D printer with methacrylate photopolymer resin. Satisfying dose distribution was achieved in patient with bolus setup. Treatment was successfully finished for one patient with the 3D printed bolus. Conclusion: The electron bolus fabrication with 3D printing technology was successfully implemented in clinic practice.

  17. Esophagogastric junction outflow obstruction is often associated with coexistent abnormal esophageal body motility and abnormal bolus transit.

    Science.gov (United States)

    Zheng, E; Gideon, R M; Sloan, J; Katz, P O

    2017-10-01

    Currently, the diagnosis of esophageal motility disorders is in part based upon a hierarchical algorithm in which abnormalities of the esophagogastric junction (EGJ) is prioritized. An important metric in evaluating the EGJ is the integrated relaxation pressure (IRP). Patients who do not have achalasia but are found to have an elevated IRP are diagnosed with EGJ outflow obstruction. It has been our observation that a subset of these patients also has a second named motility disorder and may also have abnormal bolus transit. The aim of this study is to determine the frequency of abnormal body motility and or abnormal bolus movement in patients with EGJ outflow obstruction. Further, in an effort to evaluate the potential clinical value in measuring bolus transit as a complement to esophageal manometry, specifically in patients with EGJ outflow obstruction, we analyzed the presenting symptoms of these patients. A total of 807 patients with a mean age of 53 years completed esophageal function testing with impedance monitoring and high-resolution manometry between January 2012 and October 2016. There were 74 patients with achalasia who were excluded from the study. Of the remaining 733 patients, 138 (19%) had an elevated IRP and were given a diagnosis of EGJ outflow obstruction. Among these patients, 56 (40%) were diagnosed with an abnormal motility pattern to liquids (ineffective esophageal motility = 28, distal esophageal spasm = 19, Jackhammer = 6), of which 44 (76%) had abnormal bolus transit to liquids, viscous, or both. In contrast, there were 82 patients with EGJ outflow obstruction and normal esophageal motility, of which 33 (40%) had abnormal bolus transit. Patients with preserved esophageal motility and EGJ outflow obstruction were then evaluated. Of the 733 patients, 299 (40%) had intact esophageal motility. Of the 299 patients with normal esophageal motility, 56 patients had an elevated IRP, of which 16 (28%) had abnormal bolus transit. There were 243 (33

  18. Study on scan timing using a test injection method in head CTA

    International Nuclear Information System (INIS)

    Sekito, Yuichi; Sanada, Hidenori

    2005-01-01

    In head computed tomographic angiography (CTA), circulation from arterial phase to venous phase is more rapid than that in other regions. Therefore, it is necessary to determine correct scan timing to obtain ideal CTA images. A test injection method makes it possible to set correct scan timing from the time density curve (TDC) for each subject. The method, however, has a weak point that is a time lag in an arrival time at peak point of contrast medium on TDC between the test injection and the primary examination because of the difference in total volume of contrast medium used. The purpose of this study calculated the delay time on the TDC in both scans. We used the test injection method and the bolus tracking method in the primary examination. The average errors in start time (Δt1) and slope change time (Δt2) of the contrast medium on the TDC between test injection and primary examination were 0.15 sec and 3.05 sec, respectively. The results indicated that it was important to grasp the delay time in start time and peak arrival time of the contrast medium between test injection and primary examination to obtain ideal images in head CTA. (author)

  19. Assessment of bolus transit with intraluminal impedance measurement in patients with esophageal motility disorders.

    Science.gov (United States)

    Bogte, A; Bredenoord, A J; Oors, J; Siersema, P D; Smout, A J P M

    2015-10-01

    The clinical management of patients with non-obstructive dysphagia is notoriously difficult. Esophageal impedance measurement can be used to measure esophageal bolus transit without the use of radiation exposure to patients. However, validation of measurement of bolus transit with impedance monitoring has only been performed in healthy subjects with normal motility and not in patients with dysphagia and esophageal motility disorders. The aim was, therefore, to investigate the relationship between transit of swallowed liquid boluses in healthy controls and in patients with dysphagia. Twenty healthy volunteers and 20 patients with dysphagia underwent concurrent impedance measurement and videofluoroscopy. Each subject swallowed five liquid barium boluses. The ability of detecting complete or incomplete bolus transit by means of impedance measurement was assessed, using radiographic bolus transit as the gold standard. Impedance monitoring recognized stasis and transit in 80.5% of the events correctly, with 83.9% of bolus transit being recognized and 77.2% of stasis being recognized correctly. In controls 79.8% of all swallows were scored correctly, whereas in patients 81.3% of all swallows were scored correctly. Depending on the contractility pattern, between 77.0% and 94.3% of the swallows were scored correctly. Impedance measurement can be used to assess bolus clearance patterns in healthy subjects, but can also be used to reliably assess bolus transit in patients with dysphagia and motility disorders. © 2015 John Wiley & Sons Ltd.

  20. The velocity of a radioactive bolus in the oesophagus evaluated by means of an image segmentation algorithm

    International Nuclear Information System (INIS)

    Miquelin, Charlie A; Dantas, Roberto O; Oliveira, Ricardo B; Braga, Francisco Jos H. N

    2002-01-01

    Classical scintigraphic evaluation of a radioactive bolus through the oesophagus is based on regions of interest and time/activity curves, which only gives information about the total time required for it to cross the organ. Instantaneous parameters can be obtained if the exact position (centroid) of the bolus is known. For that, one needs to know the co-ordinates of the centre of mass of the bolus radioactivity distribution. From this, one can obtain velocity at each time. Obtaining such a new parameter would be important, to try to determine whether the anatomical differences among the 3 thirds of the oesophagus have a functional correspondence or not. We have studied 5 normal volunteers (4 males, 1 female, 33-68 yo). Each volunteer swallowed (unique swallowing) 40 MBq of 99mTc-phytate in 10 ml water. Eighty frames (0.3 sec) were acquired in a scintillation camera. External marks were used to separate the pharynx from the oesophagus. Images were transformed into bitmap by means of a Sophy Medical processing module and analysed by means of the algorithm, which determines the co-ordinates of the centroid (horizontal and vertical) for each frame and instant velocities through the organ. Different velocities were found in typical evaluations. Curves representing the different positions of the bolus C and the correspondent different Vs were obtained. Different velocities of the bolus were detected during the pharyngeal phase, and proximal, mid and distal parts of the oesophagus. Larger studies are necessary, but it seems that the velocity of a radioactive bolus changes in the different parts of the oesophagus. It is reasonable to say that there is a functional correspondence to the anatomical differences in the organ (Au)

  1. Barium and meat. A comparison between pharyngeal swallow of fluid and solid boluses

    Energy Technology Data Exchange (ETDEWEB)

    Ekberg, O.; Liedberg, B.; Oewall, B.

    The influence of bolus consistency on pharyngeal swallow was radiologically studied in 24 individuals by comparing liquid barium and solid meat after chewing. Pharyngeal function was apparently performed synchronously and symmetrically on both boluses. No definite conclusion about the influence on epiglottic mobility, closure of the laryngeal vestibule and relaxation of the circopharyngeal muscle could be drawn from this study. There was no difference in the elevation of the pharynx and larynx. The transit time for a solid bolus was shorter compared with that of a fluid bous. The transit time for the apex of the bolus was shorter than for the tail. A more marked elevation of the pharynx and larynx was followed by a shorter transit time. The width of the pharyngo-esophageal segment was larger in the transverse than in the sagittal diameter during the passage of the bolus and larger on solid compared with fluid swallow. Our results reflect the ability of pharyngeal swallow to be executed with precision and with few alterations due to variable bolus consistency.

  2. Sensation of stasis is poorly correlated with impaired esophageal bolus transport

    NARCIS (Netherlands)

    Bogte, A.; Bredenoord, A. J.; Oors, J.; Siersema, P. D.; Smout, A. J. P. M.

    2014-01-01

    It is common belief that symptoms of patients with non-obstructive dysphagia are the result of impaired bolus clearance in the esophagus, usually caused by esophageal motility disorders. We therefore investigated the relationship between transit of swallowed boluses and the symptom dysphagia. Twenty

  3. Factors Influencing ACT After Intravenous Bolus Administration of 100 IU/kg of Unfractionated Heparin During Cardiac Catheterization in Children.

    Science.gov (United States)

    Muster, Ileana; Haas, Thorsten; Quandt, Daniel; Kretschmar, Oliver; Knirsch, Walter

    2017-10-01

    Anticoagulation using intravenous bolus administration of unfractionated heparin (UFH) aims to prevent thromboembolic complications in children undergoing cardiac catheterization (CC). Optimal UFH dosage is needed to reduce bleeding complications. We analyzed the effect of bolus UFH on activated clotting time (ACT) in children undergoing CC focusing on age-dependent, anesthesia-related, or disease-related influencing factors. This retrospective single-center study of 183 pediatric patients receiving UFH during CC analyzed ACT measured at the end of CC. After bolus administration of 100 IU UFH/kg body weight, ACT values between 105 and 488 seconds were reached. Seventy-two percent were within target level of 160 to 240 seconds. Age-dependent differences were not obtained ( P = .407). The ACT values were lower due to hemodilution (total fluid and crystalloid administration during CC, both P ACT values but occurred more frequently in children between 1 month and 1 year of age (91%). In conclusion, with a bolus of 100 IU UFH/kg, an ACT target level of 160 to 240 seconds can be achieved during CC in children in 72%, which is influenced by hemodilution and anticoagulant and antiplatelet premedication but not by age.

  4. Comparison of treatment with continuous subcutaneous insulin infusion versus multiple daily insulin injections with bolus calculator in patients with type 1 diabetes.

    Science.gov (United States)

    Pérez-García, L; Goñi-Iriarte, M J; García-Mouriz, M

    2015-01-01

    A study of the glycemic control, quality of life, and fear and perception of hypoglycemia by comparing continuous subcutaneous insulin infusion (CSII) group with multiple daily inyections (MDI) with bolus calculator group. This is a retrospective cohort study with following up during the first 12 months that CSII group (n=30) begins the use of "bolus wizard" and the MDI-calculator (n=30) group begins the use of the bolus calculator (Accu-Chek(®) Aviva Expert). HbA1c (3, 6 and 12 months). Questionnaires used: EsDQOL (quality of life), FH-15 (fear of hypoglycemia), and Clarke (perception of hypoglycemia). T Student and nonparametric tests. The average reduction in HbA1c during the study was significantly higher in CSII group (-0.56±0.84%) compared with the MDI group (0.097±0.94%), P=.028. The average basal insulin dose was significantly higher in the MDI group (at baseline, 6 and 12 months). No significant differences were found between the 2 treatment groups after analyzing the EsDQOL, FH-15 and Clarke questionnaires. In the CSII group, perceived quality of life assessed by the EsDQOL questionnaire was found to be better at the end of the study than at the beginning of using the insulin pump. The average reduction in HbA1c was significantly higher in the CSII group. In the CSII group, perceived quality of life was better at the end of the study than at the beginning. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  5. Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection

    International Nuclear Information System (INIS)

    Rahmer, J; Gleich, B; Borgert, J; Antonelli, A; Sfara, C; Magnani, M; Tiemann, B; Weizenecker, J

    2013-01-01

    Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases. (paper)

  6. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Science.gov (United States)

    Park, So-Yeon; Choi, Chang Heon; Park, Jong Min; Chun, MinSoo; Han, Ji Hye; Kim, Jung-In

    2016-01-01

    The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique. We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA) bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected. There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm). The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  7. Comparison of first pass bolus AIFs extracted from sequential 18F-FDG PET and DSC-MRI of mice

    International Nuclear Information System (INIS)

    Evans, Eleanor; Sawiak, Stephen J.; Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T.

    2014-01-01

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and 18 F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies

  8. Taste enhancement in food gels: Effect of fracture properties on oral breakdown, bolus formation and sweetness intensity

    NARCIS (Netherlands)

    Mosca, A.C.; Velde, van de F.; Bult, J.H.F.; Boekel, van M.A.J.S.; Stieger, M.A.

    2015-01-01

    This study investigates the effects of fracture strain and fracture stress on oral breakdown, bolus formation and sweetness intensity of semi-solid food gels containing sucrose heterogeneously distributed in layers. The sweetness intensity of gels was mainly affected by the total surface area of gel

  9. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-03-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms.

  10. The usefulness of esophagogram with marchmallow bolus in patients with esophageal related symptoms

    International Nuclear Information System (INIS)

    Yoon, Sang Wook; Kim, Ki Whang; Park, Hyo Jin; Kim, Eun Kyung; Yu, Jeong Sik; Seo, Jung Kun; Kwon, Ryang; Shin, Hyung Cheol

    1996-01-01

    To evaluate the usefulness of the esophagogram using marshmallow bolus in the evaluation of the causes of variable esophageal-related symptoms. Esophagograms using marshmallow bolus were performed on 44 patients with esophageal-related symptoms and on ten normal volunteers. Videofluoroscopic studies were also made. Patients were classified into three groups according to their esophageal-related symptoms ; those with dysphagia, those with globus symptom, and those with chest pain. Abnormal findings on an esophagogram with marshmallow were graded in to three categories ; mild, moderate, and severe. Provocation of the same symptom was also evaluated. Esophageal monometric studies were performed on 16 patients and those results were compared with the results obtained from the esophagogram using marshmallow bolus. The provocation rate of the some symptom was 33% in the first group, 47% in the second, and 24% in the third. The provocation rate was highest in the second group. The provocation rate was also higher in patients with a severe degree of abnormality on an esophagogram using marshmallow bolus. Where there were abnormal findings, an esophagogram using marshmallow bolus showed a higher abnormality rate than did a conventional esophagogram. In cases showing abnormal finding son the esophageal monometric study, an esophagogram using marshmallow bolus showed a higher provocation rate and more severe abnormality than in cases showing normal findings on manometric study. An esophagogram using marshmallow bolus will a useful radiologic screening modality for the evaluation of patients with esophageal-related symptoms

  11. The use of Coca-Cola in the management of bolus obstruction in benign oesophageal stricture.

    Science.gov (United States)

    Karanjia, N. D.; Rees, M.

    1993-01-01

    Oesophageal stricture is a complication of oesophageal reflux and may itself be complicated by bolus obstruction. We reviewed the records of patients presenting with dysphagia and who were found to have benign oesophageal strictures. We studied the outcome of bolus obstruction in 13 episodes affecting eight patients. In six episodes Coca-Cola was administered on the day before endoscopy, and in all these patients the bolus had cleared. In seven episodes nothing was administered before endoscopy, and in all seven a bolus was evident at endoscopy. In five of these seven the bolus was removed piecemeal and in each of these instances the endoscope had to be passed between two and five times. In the remaining two instances the procedure was abandoned and the patients returned to the ward for the administration of Coca-Cola. At subsequent endoscopy these patients were found to be clear of any bolus. These results suggest that the administration of Coca-Cola (or other aerated drinks) may clear a bolus in the acutely obstructed oesophagus. PMID:8476194

  12. Oral declines and mastication deficiencies cause alteration of food bolus properties.

    Science.gov (United States)

    Peyron, M-A; Santé-Lhoutellier, V; François, O; Hennequin, M

    2018-02-21

    In the elderly, masticatory function often presents failure in certain oral tasks due to impairment such as decline in muscular force, jaw or tongue motility, neuro-muscular coordination, tooth damage, malocclusion and saliva production. Great disparity is observed in the various and potentially cumulative oral declines that occur with ageing. Such difficulties may have an impact on food consumption and nutritional status. To obtain better understanding of the consequences of several oral deficiencies, a series of swallowable boluses were prepared in vitro with the AM 2 masticator apparatus with normal and deficient programming. Physiological normal mastication (NM) was simulated using in vivo data from healthy subjects. Chewing deficiencies were reproduced by alteration of NM programming to perform different levels and combinations of force loss, lack of saliva and decrease in the motility of oral elements. Poultry meatballs were used as test-food. Particle size distribution in the food bolus was measured by sieving and rheological features (hardness, cohesiveness and elasticity) were assessed with a TPA test. Compared to the NM outcome, significant and gradual deterioration of the food bolus was observed and associated with alteration in force, saliva and motility. Combinations of several failures led to greater or cumulative deficiencies in swallowable bolus properties. For the elderly presenting a high prevalence of various oral injuries, tailoring textured food cannot be ignored as a solution for remedying deficiencies and favoring the formation of a safe-swallowable bolus, which is an essential vector of nutrients. Knowing the impacts of oral injuries on the food bolus is obviously a requisite for developing diet strategies, including nutritional items for specific populations.

  13. A Patient-Specific Polylactic Acid Bolus Made by a 3D Printer for Breast Cancer Radiation Therapy.

    Directory of Open Access Journals (Sweden)

    So-Yeon Park

    Full Text Available The aim of this study was to assess the feasibility and advantages of a patient-specific breast bolus made using a 3D printer technique.We used the anthropomorphic female phantom with breast attachments, which volumes are 200, 300, 400, 500 and 650 cc. We simulated the treatment for a right breast patient using parallel opposed tangential fields. Treatment plans were used to investigate the effect of unwanted air gaps under bolus on the dose distribution of the whole breast. The commercial Super-Flex bolus and 3D-printed polylactic acid (PLA bolus were applied to investigate the skin dose of the breast with the MOSFET measurement. Two boluses of 3 and 5 mm thicknesses were selected.There was a good agreement between the dose distribution for a virtual bolus generated by the TPS and PLA bolus. The difference in dose distribution between the virtual bolus and Super-Flex bolus was significant within the bolus and breast due to unwanted air gaps. The average differences between calculated and measured doses in a 200 and 300 cc with PLA bolus were not significant, which were -0.7% and -0.6% for 3mm, and -1.1% and -1.1% for 5 mm, respectively. With the Super-Flex bolus, however, significant dose differences were observed (-5.1% and -3.2% for 3mm, and -6.3% and -4.2% for 5 mm.The 3D-printed solid bolus can reduce the uncertainty of the daily setup and help to overcome the dose discrepancy by unwanted air gaps in the breast cancer radiation therapy.

  14. Enoxaparin-induced skin necrosis at injection site after total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Max Haffner, BS

    2018-03-01

    Full Text Available Enoxaparin is a widely used low-molecular-weight heparin for perioperative thromboembolic prophylaxis. Enoxaparin-induced skin necrosis in the setting of arthroplasty has been rarely reported in the literature with varying outcomes and management decisions. Our patient developed skin necrosis at his injection site and thrombocytopenia 10 days following left total knee arthroplasty surgery and after receiving subcutaneous Lovenox injections postoperatively. The patient was started on an alternative anticoagulation based on a high suspicion for heparin-induced thrombocytopenia and the wound was monitored without surgical debridement. Our case highlights the key clinical management decisions when facing this potentially life-threatening adverse reaction. Keywords: Lovenox, Enoxaparin, Skin necrosis, Adverse reaction, Arthroplasty

  15. Endoleak detection using single-acquisition split-bolus dual-energy computer tomography (DECT)

    Energy Technology Data Exchange (ETDEWEB)

    Javor, D.; Wressnegger, A.; Unterhumer, S.; Kollndorfer, K.; Nolz, R.; Beitzke, D.; Loewe, C. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-04-15

    To assess a single-phase, dual-energy computed tomography (DECT) with a split-bolus technique and reconstruction of virtual non-enhanced images for the detection of endoleaks after endovascular aneurysm repair (EVAR). Fifty patients referred for routine follow-up post-EVAR CT and a history of at least one post-EVAR follow-up CT examination using our standard biphasic (arterial and venous phase) routine protocol (which was used as the reference standard) were included in this prospective trial. An in-patient comparison and an analysis of the split-bolus protocol and the previously used double-phase protocol were performed with regard to differences in diagnostic accuracy, radiation dose, and image quality. The analysis showed a significant reduction of radiation dose of up to 42 %, using the single-acquisition split-bolus protocol, while maintaining a comparable diagnostic accuracy (primary endoleak detection rate of 96 %). Image quality between the two protocols was comparable and only slightly inferior for the split-bolus scan (2.5 vs. 2.4). Using the single-acquisition, split-bolus approach allows for a significant dose reduction while maintaining high image quality, resulting in effective endoleak identification. (orig.)

  16. A Bolus Calculator Based on Continuous-Discrete Unscented Kalman Filtering for Type 1 Diabetics

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Aradóttir, Tinna Björk; Hagdrup, Morten

    2015-01-01

    both reduces the risk of hypoglycemia in case of an overestimated meal and the time spent in hyperglycemia if the meal size is underestimated. Faster insulin and the use of glucagon will have the potential to encourage postprandial meal bolus administration and hence will not require to accurately......In patients with type 1 diabetes, the effects of meals intake on blood glucose level are usually mitigated by administering a large amount of insulin (bolus) at mealtime or even slightly before. This strategy assumes, among other things, a prior knowledge of the meal size and the postprandial...... glucose dynamics. On the other hand, administering the meal bolus during or after mealtime could benefit from the information provided by the postprandial meal dynamics at the expense of a delayed meal bolus. The present paper investigates different bolus administration strategies (at mealtime, 15 minutes...

  17. TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

    Energy Technology Data Exchange (ETDEWEB)

    Nowik, P; Bujila, R; Merzan, D [Dept. of Medical Physics, Karolinska University Hospital, Stockholm (Sweden)

    2015-06-15

    Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

  18. 21 CFR 520.1242b - Levamisole hydrochloride tablet or oblet (bolus).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Levamisole hydrochloride tablet or oblet (bolus... § 520.1242b Levamisole hydrochloride tablet or oblet (bolus). (a) Chemical name. (-)-2,3,5,6-Tetrahydro... using in severely debilitated animals. (2) It is used in a tablet for sheep as follows: (i) Amount. 0...

  19. Comparison of first pass bolus AIFs extracted from sequential {sup 18}F-FDG PET and DSC-MRI of mice

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Eleanor, E-mail: ee244@cam.ac.uk [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Sawiak, Stephen J. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom); Behavioural and Clinical Neuroscience Institute, Department of Experimental Psychology, University of Cambridge, Cambridge, CB2 3EB (United Kingdom); Ward, Alexander O.; Buonincontri, Guido; Hawkes, Robert C.; Adrian Carpenter, T. [Wolfson Brain Imaging Centre, Department of Clinical Neurosciences, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ (United Kingdom)

    2014-01-11

    Accurate kinetic modelling of in vivo physiological function using positron emission tomography (PET) requires determination of the tracer time–activity curve in plasma, known as the arterial input function (AIF). The AIF is usually determined by invasive blood sampling methods, which are prohibitive in murine studies due to low total blood volumes. Extracting AIFs from PET images is also challenging due to large partial volume effects (PVE). We hypothesise that in combined PET with magnetic resonance imaging (PET/MR), a co-injected bolus of MR contrast agent and PET ligand can be tracked using fast MR acquisitions. This protocol would allow extraction of a MR AIF from MR contrast agent concentration–time curves, at higher spatial and temporal resolution than an image-derived PET AIF. A conversion factor could then be applied to the MR AIF for use in PET kinetic analysis. This work has compared AIFs obtained from sequential DSC-MRI and PET with separate injections of gadolinium contrast agent and {sup 18}F-FDG respectively to ascertain the technique′s validity. An automated voxel selection algorithm was employed to improve MR AIF reproducibility. We found that MR and PET AIFs displayed similar character in the first pass, confirmed by gamma variate fits (p<0.02). MR AIFs displayed reduced PVE compared to PET AIFs, indicating their potential use in PET/MR studies.

  20. Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients

    International Nuclear Information System (INIS)

    Ahn, Seung Kwon; Kim, Yong Bae; Lee, Ik Jae

    2008-01-01

    We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by 4.0-4.4% to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the

  1. The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography. A randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Karady, Julia; Panajotu, Alexisz; Kolossvary, Marton; Szilveszter, Balint; Jermendy, Adam L.; Bartykowszki, Andrea; Karolyi, Mihaly; Celeng, Csilla; Merkely, Bela; Maurovich-Horvat, Pal [Semmelweis University, MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Budapest (Hungary)

    2017-11-15

    Contrast media (CM) extravasation is a well-known complication of CT angiography (CTA). Our prospective randomized control study aimed to assess whether a four-phasic CM administration protocol reduces the risk of extravasation compared to the routinely used three-phasic protocol in coronary CTA. Patients referred to coronary CTA due to suspected coronary artery disease were included in the study. All patients received 400 mg/ml iomeprol CM injected with dual-syringe automated injector. Patients were randomized into a three-phasic injection-protocol group, with a CM bolus of 85 ml followed by 40 ml of 75%:25% saline/CM mixture and 30 ml saline chaser bolus; and a four-phasic injection-protocol group, with a saline pacer bolus of 10 ml injected at a lower flow rate before the three-phasic protocol. 2,445 consecutive patients were enrolled (mean age 60.6 ± 12.1 years; females 43.6%). Overall rate of extravasation was 0.9% (23/2,445): 1.4% (17/1,229) in the three-phasic group and 0.5% (6/1,216) in the four-phasic group (p = 0.034). Four-phasic CM administration protocol is easy to implement in the clinical routine at no extra cost. The extravasation rate is reduced by 65% with the application of the four-phasic protocol compared to the three-phasic protocol in coronary CTA. (orig.)

  2. Comparison of Two Methods of Bolus and Infusion of Tranexamic Acid in Reduction of Blood Loss in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Mohammadreza Moshari

    2018-01-01

    Full Text Available AbstractBackground: So far, many studies have been performed to determine the optimal dose and regimen of tranexamic acid to reduce preoperative and postoperative blood loss in primary total knee arthroplasty. In the present study, two different methods of administration (bolus and infusion, were compared.Materials and Methods: Forty patients were randomized in the two groups (A and B of 20 patients each. All patients received 500 mg tranexamic acid before inflation of tourniquet. Group A (mean age, 64± 6.1 years received 500 mg tranexamic acid 10 minutes before loosening of tourniquet and group B (mean age, 63.5 ± 7.7 years received 500 mg tranexamic acid through IV infusion during 6 hours from the time of tourniquet loosening (total dose of TA, 1 g in both groups. Intraoperative blood loss,postoperative drainage (in 6 and 12 hours, blood transfusion (in 48 hours, and decrease in hematocrit and hemoglobin (6 and 12 hours later, were compared between the two groups.Results: The patients in group B had lower intra- and postoperative blood loss in 6 and 12 hours and also had lower decrease in hemoglobin, and their packed cell transfusion rate was significantly lower compared to the group A.Conclusion: The findings of this study indicated that infusion administration of tranexamic acid in primary total knee arthroplasty, was more effective in the reduction of perioperative blood loss as well as need for blood transfusion in 48 hours.

  3. Effect of chest wall radiotherapy in different manners using tissue equivalent bolus on skin and lung of cavia cobayas

    International Nuclear Information System (INIS)

    Huang Wei; Qu Yaqin; Song Xiangfu; Liu Shixin; Jia Xiaojing; Guo He; Yang Lei

    2009-01-01

    Objective: To probe the influence of electron beam radiotherapy in different manners using different tissue equivalent boluses on skin and lung. Methods: Adult female cavia cobayas were randomly divided into four groups as control group, half-time with bolus group, half-time with bolus group and without bolus group. Acute-irradiation animal models were established using electron beam in different manners with or without 0.5 cm tissue equivalent bolus. Pathological changes in lung, hair vesicle and fibroblast cell count were analyzed 40 clays after irradiation. Results: The radiation dermatitis in the group with bolus was slighter than that of the group without bolus, but the radiation pneumonia was reverse. With bolus, the radiation dermatitis of haft-time group was slighter than that of full-time group. The injury repair of half-time group was more active than full-time group. Conclusions: The treatment of haft-time bolus could protect lung without serious skin complications. (authors)

  4. The Consideration of Bolus Effects of Games Attached on Lesion area

    International Nuclear Information System (INIS)

    Park, Ju Young; Ju, Sang Kyu; Park, Young Chul; Han, Young Yi; Shin, Eun Hyuk; Park, Yong Hwan

    2004-01-01

    The aim of this study is to evaluate the effect of skin dose and PDD by using wounds protecting gauzes or Vaselinespread gauzes. And it was studied that the possibility to substitute custom bolus into gauzes. 4 MV photon (CL600C, varian, US), Polystyrene Phantom (30(W) X 30(L) X 30(H)) with Markus chamber(PTW, US) were used for dose measurement. This study was distinguished natural gauzes and spread over Vaseline gauzes. We gave variety to the gauze thickness at 5, 10 and 15 sheets respectively. For comparison between using bolus and not that, we had used 1.0 cm thickness bolus so that analyzed surface dose and PDD at the same conditions above mentioned. When maximum point was defined as reference point, surface dose was measured as 35% in open beam. When the gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased as 69, 80 and 91% respectively according to thickness of gauzes. When spread over Vaseline gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased respectively as 98, 100 and 98% according to thickness of gauzes. Also when 0.5 cm bolus and 5 sheets gauzes were composed, surface dose was measured as 98%. The gauzes that were attached to skin surface in radiation therapy had been scattering material and contributed increasing surface dose without variation of percentage depth dose. However, if we want to delivery much dose to skin surface then we have to apply many sheets of gauzes to skin surface. Although we get easy that result by bolus or spread over Vaseline gauzes, we have to revise percentage depth dose at calculation. Therefore, if we find pertinent conditions based on measured data that are considered skin dose and patient setup efficiency, to replace custom bolus with gauzes will be helpful to efficient treatment.

  5. The effect of food bolus location on jaw movement smoothness and masticatory efficiency.

    Science.gov (United States)

    Molenaar, W N B; Gezelle Meerburg, P J; Luraschi, J; Whittle, T; Schimmel, M; Lobbezoo, F; Peck, C C; Murray, G M; Minami, I

    2012-09-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to determine whether experimental differences in food bolus location (anterior versus posterior) had an effect on masticatory efficiency and jaw movement smoothness. Jaw movement smoothness was evaluated by measuring jerk-cost (calculated from acceleration) with an accelerometer that was attached to the skin of the mentum of 10 asymptomatic subjects, and acceleration was recorded during chewing on two-colour chewing gum, which was used to assessed masticatory efficiency. Chewing was performed under two conditions: posterior chewing (chewing on molars and premolars only) and anterior chewing (chewing on canine and first premolar teeth only). Jerk-cost and masticatory efficiency (calculated as the ratio of unmixed azure colour to the total area of gum, the unmixed fraction) were compared between anterior and posterior chewing with the Wilcoxon signed rank test (two-tailed). Subjects chewed significantly less efficiently during anterior chewing than during posterior chewing (P = 0·0051). There was no significant difference in jerk-cost between anterior and posterior conditions in the opening phase (P = 0·25), or closing phase (P = 0·42). This is the first characterisation of the effect of food bolus location on jaw movement smoothness at the same time as recording masticatory efficiency. The data suggest that anterior chewing decreases masticatory efficiency, but does not influence jerk-cost. © 2012 Blackwell Publishing Ltd.

  6. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    International Nuclear Information System (INIS)

    Fujimoto, K; Yuasa, Y; Shiinoki, T; Hanazawa, H; Shibuya, K

    2016-01-01

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  7. SU-F-T-500: The Effectiveness of a Patient Specific Bolus Made by Using Three-Dimensional Printing Technique in Photon Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, K; Yuasa, Y [Department of Radiological Technology, Yamaguchi University Hospital (Japan); Shiinoki, T; Hanazawa, H; Shibuya, K [Department of Radiation Oncology, Graduate school of Medicine, Yamaguchi University (Japan)

    2016-06-15

    Purpose: A commercially available bolus (commercial-bolus) would not completely contact with the irregular shape of a patient’s skin. The purposes of this study were to customize a patient specific three-dimensional (3D) bolus using a 3D printer (3D-bolus) and to evaluate its clinical feasibility for photon radiotherapy. Methods: The 3D-bolus was designed using a treatment planning system (TPS) in DICOM-RT format. To print the 3D bolus, the file was converted into stereolithography format. To evaluate its physical characteristics, plans were created for water equivalent phantoms without the bolus, with the 3D-bolus printed in a flat form, and with the virtual bolus which supposed a commercial-bolus. These plans were compared with the percent depth dose (PDD) measured from the TPS. Furthermore, to evaluate its clinical feasibility, the treatment plans were created for RANDO phantoms without the bolus and with the 3D-bolus which was customized for contacting with the surface of the phantom. Both plans were compared with the dose volume histogram (DVH) of the target volume. Results: In the physical evaluation, dmax of the plan without the bolus, with the 3D-bolus, and with the virtual bolus were 2.2 cm, 1.6 cm, and 1.7 cm, respectively. In the evaluation of clinical feasibility, for the plan without the bolus, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 102.6 %, 1.6 %, 88.8 %, 57.2 %, and 69.3 %, respectively. By using the 3D-bolus, the prescription dose could be delivered to at least 90 % of the target volume, Dmax, Dmin, Dmean, D90%, and V90% of the target volume were 104.3 %, 91.6 %, 92.1 %, 91.7 %, and 98.0 %, respectively. The 3D-bolus has the potential to be useful for providing effective dose coverage in the buildup region. Conclusion: A 3D-bolus produced using 3D printing technique is comparable to a commercially available bolus.

  8. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    International Nuclear Information System (INIS)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K

    2015-01-01

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology

  9. SU-C-213-05: Evaluation of a Composite Copper-Plastic Material for a 3D Printed Radiation Therapy Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Vitzthum, L; Ehler, E; Sterling, D; Reynolds, T; Higgins, P; Dusenbery, K [University of Minnesota, Minneapolis, MN (United States)

    2015-06-15

    Purpose: To evaluate a novel 3D printed bolus fabricated from a copper-plastic composite as a thin flexible, custom fitting device that can replicate doses achieved with conventional bolus techniques. Methods: Two models of bolus were created on a 3D printer using a composite copper-PLA/PHA. Firstly, boluses were constructed at thicknesses of 0.4, 0.6 and 0.8 mm. Relative dose measurements were performed under the bolus with an Attix Chamber as well as with radiochromic film. Results were compared to superficial Attix Chamber measurements in a water equivalent material to determine the dosimetric water equivalence of the copper-PLA/PHA plastic. Secondly, CT images of a RANDO phantom were used to create a custom fitting bolus across the anterolateral scalp. Surface dose with the bolus placed on the RANDO phantom was measured with radiochromic film at tangential angles with 6, 10, 10 flattening filter free (FFF) and 18 MV photon beams. Results: Mean surface doses for 6, 10, 10FFF and 18 MV were measured as a percent of Dmax for the flat bolus devices of each thickness. The 0.4 mm thickness bolus was determined to be near equivalent to 2.5 mm depth in water for all four energies. Surface doses ranged from 59–63% without bolus and 85–90% with the custom 0.4 mm copper-plastic bolus relative to the prescribed dose for an oblique tangential beam arrangement on the RANDO phantom. Conclusion: Sub-millimeter thickness, 3D printed composite copper-PLA/PHA bolus can provide a build-up effect equivalent to conventional bolus. At this thickness, the 3D printed bolus allows a level of flexure that may provide more patient comfort than current 3D printing materials used in bolus fabrication while still retaining the CT based custom patient shape. Funding provided by an intra-department grant of the University of Minnesota Department of Radiation Oncology.

  10. SU-F-T-517: Determining the Tissue Equivalence of a Brass Mesh Bolus in a Reconstructed Chest Wall Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shekel, E; Epstein, D; Levin, D [Dept of radiotherapy, Assuta Medical Centers, Tel Aviv (Israel)

    2016-06-15

    Purpose: To determine the tissue equivalence of a brass mesh bolus (RPD) in the setting of a reconstructed chest wall irradiation Methods: We measured breast skin dose delivered by a tangential field plan on an anthropomorphic phantom using Mosfet and nanoDot (Landauer) dosimeters in five different locations on the breast. We also measured skin dose using no bolus, 5mm and 10 mm superflab bolus. In the Eclipse treatment planning system (Varian, Palo Alto, CA) we calculated skin dose for different bolus thicknesses, ranging from 0 to 10 mm, in order to evaluate which calculation best matches the brass mesh measurements, as the brass mesh cannot be simulated due to artefacts.Finally, we measured depth dose behavior with the brass mesh bolus to verify that the bolus does not affect the dose to the breast itself beyond the build-up region. Results: Mosfet and nanoDot measurements were consistent with each other.As expected, skin dose measurements with no bolus had the least agreement with Eclipse calculation, while measurements for 5 and 10 mm agreed well with the calculation despite the difficulty in conforming superflab bolus to the breast contour. For the brass mesh the best agreement was for 3 mm bolus Eclipse calculation. For Mosfets, the average measurement was 90.8% of the expected dose, and for nanoDots 88.33% compared to 83.34%, 88.64% and 93.94% (2,3 and 5 mm bolus calculation respectively).The brass mesh bolus increased skin dose by approximately 25% but there was no dose increase beyond the build-up region. Conclusion: Brass mesh bolus is most equivalent to a 3 mm bolus, and does not affect the dose beyond the build-up region. The brass mesh cannot be directly calculated in Eclipse, hence a 3mm bolus calculation is a good reflection of the dose response to the brass mesh bolus.

  11. A custom three-dimensional electron bolus technique for optimization of postmastectomy irradiation

    International Nuclear Information System (INIS)

    Perkins, George H.; McNeese, Marsha D.; Antolak, John A.; Buchholz, Thomas A.; Strom, Eric A.; Hogstrom, Kenneth R.

    2001-01-01

    Purpose: Postmastectomy irradiation (PMI) is a technically complex treatment requiring consideration of the primary tumor location, possible risk of internal mammary node involvement, varying chest wall thicknesses secondary to surgical defects or body habitus, and risk of damaging normal underlying structures. In this report, we describe the application of a customized three-dimensional (3D) electron bolus technique for delivering PMI. Methods and Materials: A customized electron bolus was designed using a 3D planning system. Computed tomography (CT) images of each patient were obtained in treatment position and the volume to be treated was identified. The distal surface of the wax bolus matched the skin surface, and the proximal surface was designed to conform to the 90% isodose surface to the distal surface of the planning target volume (PTV). Dose was calculated with a pencil-beam algorithm correcting for patient heterogeneity. The bolus was then fabricated from modeling wax using a computer-controlled milling device. To aid in quality assurance, CT images with the bolus in place were generated and the dose distribution was computed using these images. Results: This technique optimized the dose distribution while minimizing irradiation of normal tissues. The use of a single anterior field eliminated field junction sites. Two patients who benefited from this option are described: one with altered chest wall geometry (congenital pectus excavatum), and one with recurrent disease in the medial chest wall and internal mammary chain (IMC) area. Conclusion: The use of custom 3D electron bolus for PMI is an effective method for optimizing dose delivery. The radiation dose distribution is highly conformal, dose heterogeneity is reduced compared to standard techniques in certain suboptimal settings, and excellent immediate outcome is obtained

  12. Effects of a sour bolus on the intramuscular electromyographic (EMG) activity of muscles in the submental region.

    Science.gov (United States)

    Palmer, Phyllis M; McCulloch, Timothy M; Jaffe, Debra; Neel, Amy T

    2005-01-01

    A sour bolus has been used as a modality in the treatment of oropharyngeal dysphagia based on the hypothesis that this stimulus provides an effective preswallow sensory input that lowers the threshold required to trigger a pharyngeal swallow. The result is a more immediate swallow onset time. Additionally, the sour bolus may invigorate the oral muscles resulting in stronger contractions during the swallow. The purpose of this investigation was to compare the intramuscular electromyographic activity of the mylohyoid, geniohyoid, and anterior belly of the digastric muscles during sour and water boluses with regard to duration, strength, and timing of muscle activation. Muscle duration, swallow onset time, and pattern of muscle activation did not differ for the two bolus types. Muscle activation time was more tightly approximated across the onsets of the three muscles when a sour bolus was used. A sour bolus also resulted in a stronger muscle contraction as evidenced by greater electromyographic activity. These data support the use of a sour bolus as part of a treatment paradigm.

  13. Soft-robotic esophageal swallowing as a clinically-inspired bolus rheometry technique

    International Nuclear Information System (INIS)

    Dirven, Steven; Allen, Jacqueline; Xu, Weiliang; Cheng, Leo K

    2017-01-01

    To investigate the impact of viscosity and peristaltic transport parameters on manometric pressure signatures, a reproducible swallowing process is required. Due to inter- and intra-subject variability from swallow to swallow, the human body does not represent an optimal mechanism for such an investigation. A smooth and continuous swallowing soft-robot has been developed to produce biomimetic swallowing trajectories, and is proposed to operate as a bench-top bolus rheometric investigation method. The method compares conventional viscometry and pressure signature findings from robotic swallowing experiments. The robotic aspect of experimentation involved 450 biomimetic swallows (10 repetitions of 45 unique experiments). The method examined swallowing transport in three dimensions: bolus formulation, peristaltic wavelength, and peristaltic velocity, each of which are known to contribute to safe and effective swallowing in vivo . It is found that the pressure gradients and magnitudes are commensurate with clinical reports on biological swallowing, on the order of 100 mmHg peak, however, the relationship between viscosity and pressure signatures is less clear. Bolus transport cannot be predicted as a function of bolus viscosity alone. Traditional viscometric data at 50 s −1 , as used in clinical practice, may not be a strong indicator of swallow effort, safety, or efficacy in vivo . (paper)

  14. Switching to multiple daily injection therapy with glulisine improves glycaemic control, vascular damage and treatment satisfaction in basal insulin glargine-injected diabetic patients.

    Science.gov (United States)

    Yanagisawa, Katsuyuki; Ashihara, Junya; Obara, Shinji; Wada, Norio; Takeuchi, Masayoshi; Nishino, Yuri; Maeda, Sayaka; Ishibashi, Yuji; Yamagishi, Sho-ichi

    2014-11-01

    Basal and bolus insulin therapy is required for strict blood control in diabetic patients, which could lead to prevention of vascular complications in diabetes. However, the optimal combination regimen is not well established. Fifty-nine diabetic patients (49 type 1 and 10 type 2; 52.9 ± 13.3 years old) whose blood glucose levels were uncontrolled (HbA1c  > 6.2%) by combination treatment of basal insulin glargine with multiple daily pre-meal injections of bolus short-acting insulin [aspart (n = 19), lispro (n = 37) and regular human insulin (n = 3)] for at least 8 weeks were enrolled in this study. We examined whether glycaemic control and vascular injury were improved by replacement of short-acting insulin with glulisine. Patient satisfaction was assessed with Diabetes Treatment Satisfaction Questionnaire. Although bolus and basal insulin doses were almost unchanged before and after replacement therapy, switching to glulisine insulin for 24 weeks significantly decreased level of HbA1c , advanced glycation end products (AGEs), soluble receptor for AGEs (sRAGE), monocyte chemoattractant protein-1 (MCP-1) and urinary albumin excretion. In multiple stepwise regression analysis, change in MCP-1 values from baseline (ΔMCP-1) was a sole determinant of log urinary albumin excretion. ΔAGEs and ΔsRAGE were independently correlated with each other. The relationship between ΔMCP-1 and ΔsRAGE was marginally significant (p = 0.05). Replacement of short-acting insulin by glulisine significantly increased Diabetes Treatment Satisfaction Questionnaire scores. Our present study suggests that combination therapy of glargine with multiple daily pre-meal injections of glulisine might show superior efficacy in controlling blood glucose, preventing vascular damage and improving treatment satisfaction in diabetic patients. Copyright © 2014 John Wiley & Sons, Ltd.

  15. EFFECT OF A BITTER BOLUS ON ORAL, PHARYNGEAL AND ESOPHAGEAL TRANSIT OF HEALTHY SUBJECTS

    Directory of Open Access Journals (Sweden)

    Leda Maria Tavares ALVES

    2013-03-01

    Full Text Available Context During swallowing, boluses stimulate sensory receptors of the oral, pharyngeal, laryngeal, and esophageal regions. Sweet and tasteless foods are more acceptable for swallowing than bitter foods. A bitter bolus is unpleasant for most subjects. Our hypothesis was that the ingestion of a bitter bolus might alter the oral behavior, pharyngeal and esophageal transit when compared to a sweet bolus. Objective To evaluate whether the bitter taste of a liquid bolus causes alteration on oral, pharyngeal and/or esophageal transit in normal subjects in comparison with sweet bolus.' Method Scintigraphic evaluation of oral, pharyngeal and esophageal transit was performed in 43 asymptomatic subjects, 22 women and 21 men, ages 23-71 years, without problems with the ingestion of liquid and solid foods, and without digestive, cardiac or neurologic diseases. Each subject swallowed in random sequence and at room temperature 5 mL of a liquid bolus with bitter taste, prepared with 50 mL of water with 2 g of leaves of Peumus boldus, heated until boiling (boldus tea, and 5 mL of a liquid bolus with sweet taste, prepared with 50 mL of water with 3 g of sucrose, both labeled with 37 MBq of technetium phytate (Tc99m. Results There was no difference between the bitter bolus and the sweet bolus in mouth, pharynx and esophageal transit and clearance duration and in the amount of residues. Conclusion A bitter bolus, considered an unpleasant bolus, does not alter the duration of oral, pharyngeal and esophageal phases of swallowing, when compared with a sweet bolus, considered a pleasant bolus. Contexto Durante a deglutição o bolo estimula os receptores sensoriais da boca, faringe, laringe e esôfago. Os alimentos doces e sem gosto são mais aceitáveis para a deglutição do que os alimentos amargos, que tem gosto desagradável para a maioria dos indivíduos. A hipótese destes autores era que a ingestão de um bolo amargo pode alterar o trânsito oral

  16. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Shiqin [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Moran, Kathryn [Queen Elizabeth II Health Sciences Centre, Nova Scotia Cancer Centre, Halifax, Nova Scotia (Canada); Robar, James L. [Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia (Canada)

    2014-08-15

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

  17. Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

    International Nuclear Information System (INIS)

    Su, Shiqin; Moran, Kathryn; Robar, James L.

    2014-01-01

    This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues

  18. The Interactive Effect of Diabetes Family Conflict and Depression on Insulin Bolusing Behaviors for Youth.

    Science.gov (United States)

    Maliszewski, Genevieve; Patton, Susana R; Midyett, L Kurt; Clements, Mark A

    2017-05-01

    Adherence to type 1 diabetes management declines as children enter adolescence. For youth, psychosocial variables including mood and interpersonal relationships play a large role in diabetes maintenance. The current study assessed the unique and interactive roles diabetes family conflict and depression have on insulin bolusing behaviors for youth ages 10-16 years. Ninety-one youth-parent dyads completed a survey assessing family conflict and depression. Mean daily blood glucose levels, mealtime insulin bolus scores ( BOLUS), and glycated hemoglobin (HbA1c) were collected from the medical record as outcome variables. Parent-reported diabetes-related family conflict and youths' endorsed depression both significantly predicted insulin bolusing behavior, R 2 = .13, F(2, 88) = 6.66, P family conflict and youth depression played a significant role in youths' bolusing behaviors, above and beyond that which was predicted by conflict and depression separately, R 2 = .18, F change (1, 87) = 4.63, P family conflict, while there was no change in BOLUS scores among depressed youth living in families reporting less conflict. Findings underscore the importance of screening for depression and family conflict in youth experiencing or at risk for poor adherence to mealtime insulin and higher HbA1c levels.

  19. Pre-pharyngeal swallow effects of recurrent laryngeal nerve lesion on bolus shape and airway protection in an infant pig model

    Science.gov (United States)

    Gould, Francois D. H.; Yglesias, B.; Ohlemacher, J.; German, R. Z.

    2016-01-01

    Recurrent laryngeal nerve (RLN) damage in infants leads to increased dysphagia and aspiration pneumonia. Recent work has shown that intra oral transport and swallow kinematics change following RLN lesion, suggesting potential changes in bolus formation prior to the swallow. In this study we used geometric morphometrics to understand the effect of bolus shape on penetration and aspiration in infants with and without RLN lesion. We hypothesized 1) that geometric bolus properties are related to airway protection outcomes and 2) that in infants with RLN lesion, the relationship between geometric bolus properties and dysphagia is changed. In five infant pigs, dysphagia in 188 swallows was assessed using the Infant Mammalian Penetration Aspiration Score (IMPAS). Using images from high-speed VFSS, bolus shape, bolus area, and tongue outline were quantified digitally. Bolus shape was analyzed using elliptical Fourier analysis, and tongue outline using polynomial curve fitting. Despite large inter-individual differences, significant within individual effects of bolus shape and bolus area on airway protection exist. The relationship between penetration-aspiration score and both bolus area and shape changed post lesion. Tongue shape differed between pre and post lesion swallows, and between swallows with different IMPAS scores. Bolus shape and area affect airway protection outcomes. RLN lesion changes that relationship, indicating that proper bolus formation and control by the tongue requires intact laryngeal sensation. The impact of RLN lesion on dysphagia is pervasive. PMID:27873091

  20. Amniotic fluid index predicts the relief of variable decelerations after amnioinfusion bolus.

    Science.gov (United States)

    Spong, C Y; McKindsey, F; Ross, M G

    1996-10-01

    Our purpose was to determine whether intrapartum amniotic fluid index before amnioinfusion can be used to predict response to therapeutic amnioinfusion. Intrapartum patients (n = 85) with repetitive variable decelerations in fetal heart rate that necessitated amnioinfusion (10 ml/min for 60 minutes) underwent determination of amniotic fluid index before and after bolus amnioinfusion. The fetal heart tracing was scored (scorer blinded to amniotic fluid index values) for number and characteristics of variable decelerations before and 1 hour after initiation of amnioinfusion. The amnioinfusion was considered successful if it resulted in a decrease of > or = 50% in total number of variable decelerations or a decrease of > or = 50% in the rate of atypical or severe variable decelerations after administration of the bolus. Spontaneous vaginal births before completion of administration of the bolus (n = 18) were excluded from analysis. The probability of success of amnioinfusion in relation to amniotic fluid index was analyzed with the chi(2) test for progressive sequence. The mean amniotic fluid index before amnioinfusion was 6.2 +/- 3.3 cm. An amniotic fluid index of amnioinfusion decreased with increasing amniotic fluid index before amnioinfusion (76% [16/21] when initial amniotic fluid index was 0 to 4 cm, 63% [17/27] when initial amniotic fluid index was 4 to 8 cm, 44% [7/16] when initial amniotic fluid index was 8 to 12 cm, and 33% [1/3] when initial amniotic fluid index was > 12 cm, p = 0.03). The incidence of nuchal cords or true umbilical cord knots increased in relation to amniotic fluid index before amnioinfusion. Amniotic fluid index before amnioinfusion can be used to predict the success of amnioinfusion for relief of variable decelerations in fetal heart rate. Failure of amnioinfusion at a high amniotic fluid index before amnioinfusion may be explained by the increased prevalence of nuchal cords or true knots in the umbilical cord.

  1. Custom bolus of hydrogel: dosimetric characterization, clinical use and placement uncertainties; Bolus de compensación personalizado de hidrogel: Caracterización radiológica, uso clínico e incertidumbre de colocación

    Energy Technology Data Exchange (ETDEWEB)

    Pérez-García, H.; Antón, D.; Miguel, D.; Ángel del Castillo, D.; Alonso, D.; De Frutos, J.; Pérez, C.

    2017-11-01

    When using electron beams over irregular surfaces it shows remarkable dose heterogeneity in target tissue, the use of a hydrogel bolus by Varihesive® ConvaTec as a custom bolus is proposed to compensate this effect. Radiological characterization is carried out comparing hydrogel with water by a CT study and by measuring percentage depth dose for electron beams. The dosimetric impact due to the uncertainty of bolus placement is quantitatively evaluated and it is concluded that the use of hydrogel is an acceptable solution as compensation bolus with radiological properties similar to water. [Spanish] La incidencia de un campo de electrones en una superficie irregular produce distribuciones heterogéneas de dosis. En este trabajo se propone el uso de un bolus personalizado de hidrogel Varihesive® de ConvaTec para compensar dichas irregularidades. El hidrogel se caracteriza radiológicamente comparándolo con agua mediante una adquisición TC y se obtiene el porcentaje de dosis en profundidad para campos de electrones. Se evalúa cuantitativamente el impacto dosimétrico debido a la incertidumbre de colocación y se concluye que el uso de hidrogel resulta una solución aceptable como bolus de compensación con propiedades radiológicas similares al agua.

  2. Endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles.

    Science.gov (United States)

    Fukatsu, H; Nohara, K; Kotani, Y; Tanaka, N; Matsuno, K; Sakai, T

    2015-08-01

    It is known that solid food is transported to the pharynx actively in parallel to it being crushed by chewing and mixed with saliva in the oral cavity. Therefore, food bolus formation should be considered to take place from the oral cavity to the pharynx. In previous studies, the chewed food was evaluated after the food had been removed from the oral cavity. However, it has been pointed out that spitting food out of the oral cavity interferes with natural food bolus formation. Therefore, we observed food boluses immediately before swallowing using an endoscope to establish a method to evaluate the food bolus-forming function, and simultaneously performed endoscopic evaluation of food bolus formation and its relationship with the number of chewing cycles. The subject was inserted the endoscope nasally and instructed to eat two coloured samples of boiled rice simultaneously in two ingestion conditions ('as usual' and 'chewing well'). The condition of the food bolus was graded into three categories for each item of grinding, mixing and aggregation and scored 2, 1 and 0. The score of aggregation was high under both ingestion conditions. The scores of grinding and mixing tended to be higher in subjects with a high number of chewing cycles, and the score of aggregation was high regardless of the number of chewing cycles. It was suggested that food has to be aggregated, even though the number of chewing cycles is low and the food is not ground or mixed for a food bolus to reach the swallowing threshold. © 2015 John Wiley & Sons Ltd.

  3. Botulinum toxin type A injections for the management of muscle tightness following total hip arthroplasty: a case series

    Directory of Open Access Journals (Sweden)

    Delanois Ronald E

    2009-08-01

    Full Text Available Abstract Background Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty. Methods Ten patients (14 hips who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks. Results At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees. Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points prior to injection to a mean of 96 points (range, 93 to 98 at final follow-up. There were no serious treatment-related adverse events. Conclusion Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.

  4. Discounting the duration of bolus exposure in impedance testing underestimates acid reflux.

    Science.gov (United States)

    Vikneswaran, Namasivayam; Murray, Joseph A

    2016-06-08

    Combined impedance-pH testing (MII) allows for detection of reflux episodes regardless of pH. However impedance-based diagnosis of reflux may not routinely account for duration of the reflux episode. We hypothesize that impedance testing may be less sensitive than pH-testing in detecting acid reflux off therapy as a result of discounting duration of exposure. Baseline characteristics and reflux parameters of MII studies performed off-anti-secretory medications were analyzed. Studies on acid suppressive medication and those with recording times less than 20 h or low baseline impedance were excluded. A total of 73 consecutive MII studies were analyzed of which 31 MII studies had elevated acid exposure while 16 were abnormal by impedance criteria. MII testing off-therapy was more likely to be abnormal by pH criteria (percent time pH reflux):[42 vs 22 % (p =0.02)]. Acid exposure (percent time pH acid reflux episodes [42 vs 34 % (p acid clearance time (pH-detected) was significantly longer than median bolus clearance time (impedance-detected) in the total [98.7 s vs 12.6 s (p acid clearance time (pH-detected) and the median bolus clearance time (impedance-detected) was significantly higher in the recumbent position compared to the upright position [11. vs 5.3 (p = 0.01)]. Ambulatory impedance testing underestimates acid reflux compared to esophageal acid exposure by discounting the prolonged period of mucosal contact with each acid reflux episode, particularly in the recumbent position.

  5. Cineradiography of the liquid bolus swallow. A study of the speed ot the bolus and peristaltic wave and of movement of the hyoid bone, larynx, and epiglottis

    International Nuclear Information System (INIS)

    Sundgren, P.

    1991-01-01

    In the evaluation of the dysphagic patient, radiology is crucial as a technique for monitoring morphology and function. In particular, high-speed cineradiography can reveal a variety of pharyngeal dysfunctions. However, in the literature and in practice the difference between normal and abnormal function is not always clear. This monography is based on high-speed cineradiographies of swallowing in 75 non-dysphagic volunteers and in 189 dysphagic patients. The purpose was to study whether differences in bolus volumes, patient position, age and gender had any effects on the following parameters: the speed of the peristaltic wave and apex of the liquid barium bolus, the length of movement and the movement pattern of the hyoid bone and larynx, and epiglottic function. The study disclosed that the speed of the bolus, the anterior-superior movement and net movement of the hyoid bone increased significantly with larger bolus volumes. The position of the individual in relation to gravity significantly influenced the speed of peristalsis. In most of the measured parameters there were no differences between non-dysphagic and dysphagic individuals expect for differences in the intrapersonal variations and in the anterior-superior movement of the hyoid bone. In patients with pharyngeal dysfunction the initial stage of the elevation of the larynx was significantly lower than in patients without dysfunction. The approximation of the thyroid cartilage to the hyoid bone was significantly greater in individuals with normal epiglottic function than in those with epiglottic dysmobility. It is suggested that abnormal speed of peristalsis may be a mild form of dysfunction. Measurements of the aforementioned speed and movements can be done if bolus volume, age and position of the patient, film speed and magnifications factors are known. Hypotheses concerning epiglottic function and central control of swallowing are proposed. (au)

  6. Use of a marshmallow bolus for evaluating lower esophageal mucosal rings.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W; Wu, W C

    1991-07-01

    Sixty-three patients (35 women, 28 men; mean age 55 yr) with lower esophageal mucosal ring shown radiographically were examined with a semi-solid bolus consisting of a portion of a standard marshmallow. The most common symptom was dysphagia, present in 46 (73%) patients. Impaction of the marshmallow bolus by the ring occurred in 40 (63%) of the 63 patients, and produced symptoms in 27 (68%) of these 40 patients. Nine (14%) rings were detected radiographically only with a solid bolus; eight of these patients had dysphagia and seven rings were 20 mm or less in caliber. Impaction related to ring caliber, and was found in all 17 (100%) rings that were 13 mm or less in diameter, in 17/24 (71%) 14- to 19-mm rings, and in 6/22 (27%) rings 20 mm or more in caliber. Endoscopy in 23 patients detected 16 (70%) rings, and also depended on ring caliber: less than or equal to 13 mm, 6/6 (100%); 14-19 mm, 5/9 (56%); greater than or equal to 20 mm, 5/8 (63%). Marshmallow impaction occurred in 17 (74%) of 23 patients who had endoscopy; three of the 23 patients had normal endoscopy. In conclusion, radiographic examination supplemented by the use of a marshmallow bolus best detects lower esophageal mucosal ring.

  7. The impact of mastication, salivation and food bolus formation on salt release during bread consumption.

    Science.gov (United States)

    Tournier, Carole; Grass, Manon; Septier, Chantal; Bertrand, Dominique; Salles, Christian

    2014-11-01

    Health authorities recommend higher fibre and lower salt content in bread products. However, these basic ingredients of bread composition are multifunctional, and important changes in their content influence the texture, flavour and acceptability of the product. This study was designed to investigate the link between oral processing, bolus formation and sodium release during the consumption of four different breads that varied in composition and structure. Chewing behaviour was determined by surface electromyography, and salivation was quantified from the water content of the boluses collected. The kinetics of bread degradation during food bolus formation was characterised by measuring the bolus heterogeneity by texture image analysis, and sodium release into the saliva was quantified. Mastication and salivation varied between products and between subjects, thus highlighting different bolus formation strategies. In vivo salt release was mainly explained by mastication parameters. The initial slope of sodium release increased when the chewing muscles' activity increased, and the maximum sodium concentration was reached later when more masticatory cycles were required to reach the swallowing point.

  8. Evaluation of a commercially available molybdate formulation and zinc oxide boluses in preventing hepatic copper accumulation and thus enzootic icterus in sheep

    Directory of Open Access Journals (Sweden)

    C.J. Botha

    2001-07-01

    Full Text Available The efficacy of a molybdate formulation and a zinc oxide bolus as prophylactic agents for enzootic icterus was evaluated in sheep. Before copper loading, liver biopsies were performed on 12 male, 6-month-old, Mutton Merino sheep to determine hepatic copper (Cu and zinc (Zn concentrations. The animals were restrictively randomised according to liver copper concentrations to 3 treatment groups (n = 4 to achieve similar mean liver copper concentrations per group. All sheep received 4 m /kg of a 0.5 %aqueous solution of CuSO4·5H2O intraruminally 7 days per week for 10 weeks. On Day 0 the sheep in the Mo-group were injected subcutaneously with 42 mg molybdenum (Mo contained in a commercial molybdate formulation. The animals in the Zn-group each received a zinc oxide bolus, containing 43 g zinc oxide, via a rumen cannula. Treatment was repeated on Day 42. Four animals served as untreated controls. Urinary copper excretion, plasma copper concentration, haematocrit and glutamate dehydrogenase (GLDH activity were determined throughout the trial. The animals were sacrificed after 10 weeks and liver samples were submitted for histopathological examination. Liver and kidney copper and zinc concentrations were determined. Neither the molybdate treatment nor the zinc oxide boluses prevented hepatic copper accumulation. The urinary copper excretion, plasma copper concentration, haematocrit and GLDH activity were not significantly different (P > 0.05 from the controls.

  9. Clinical application analysis of andrographolide total ester sulfonate injection, a traditional Chinese medicine licensed in China.

    Science.gov (United States)

    Zhao, Ying; Huang, Pu; Chen, Zhe; Zheng, Si-Wei; Yu, Jin-Yang; Shi, Chen

    2017-04-01

    Andrographolide total ester sulfonate (ATES) injection is one of the products of traditional Chinese medicine (TCM) currently used against viral infection in China. ATES injection was approved for manufacturing and marketing in January 2002. It is indicated for acute respiratory infections, tonsillitis, chronic obstructive pulmonary disease, influenza, foot and mouth disease, bronchiolitis, herpangina, mumps, infectious mononucleosis and psychosis. However, its usage also carries risk. We investigated the use of ATES at the Wuhan Union Hospital from January 2014 to December 2014 and evaluated its real-world clinical application using the hospital centralized monitoring method. A total of 848 cases were enrolled in this study. In these cases, it was mainly used for postoperative anti-inflammation and treating upper respiratory infection, pneumonia and bronchitis. Among them, 39.86% were contraindicated. Irregular medication of adults and children accounted for 1.91% and 23.38%, respectively. Improper choice of solvent accounted for 3.18%. The choice of intravenous drip versus aerosol inhalation was reasonable. A case of adverse events (AEs) was observed in the monitoring period, and the incidence of adverse drug reaction (ADR) of ATES injection was 0.12%. ATES injection in our hospital is relatively safe with a low incidence of adverse reactions. The study assesses the clinical usage and adverse reactions of ATES injection, and provides suggestions for rational use in clinical practice.

  10. Saving radiation dose and contrast media in intravenous digital subtraction angiography by use of bolus chasing

    International Nuclear Information System (INIS)

    Rueckforth, J.; Schuermann, K.; Vorwerk, D.; Guenther, R.W.

    1998-01-01

    Purpose: This study evaluates the dose area product, the amount of contrast media and the examination quality of the bolus chasing technique compared to the single-step technique in intravenous digital subtraction angiography. Material and Methods: 15 examinations each with bolus chasing and single-step technique were compared. The dose area product and the volume of contrast media were recorded. The examination quality was scored by two examiners. Results: With bolus chasing the volume of the administered contrast media could be decreased on average by 114 ml (43%). The difference between the dose area product of bolus chasing (722 dGy/cm 2 ) and single-step technique (1910 dGy/cm 2 ) was significant. No significant difference in examination quality was found. Conclusions: The intravenous bolus chasing technique is a practicable method. Compared to the single-step technique it allows a remarkable dose reduction and a low consumption of contrast media without restriction of examination quality. (orig.) [de

  11. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis - A Cox model analysis.

    Science.gov (United States)

    Delbarre, Angélique; Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee replacement and show that patients treated with hyaluronic acid have similar direct medical costs for ambulatory care compared to patients treated with corticosteroids only.

  12. An additional bolus of rapid-acting insulin to normalise postprandial cardiovascular risk factors following a high-carbohydrate high-fat meal in patients with type 1 diabetes: A randomised controlled trial.

    Science.gov (United States)

    Campbell, Matthew D; Walker, Mark; Ajjan, Ramzi A; Birch, Karen M; Gonzalez, Javier T; West, Daniel J

    2017-07-01

    To evaluate an additional rapid-acting insulin bolus on postprandial lipaemia, inflammation and pro-coagulation following high-carbohydrate high-fat feeding in people with type 1 diabetes. A total of 10 males with type 1 diabetes [HbA 1c 52.5 ± 5.9 mmol/mol (7.0% ± 0.5%)] underwent three conditions: (1) a low-fat (LF) meal with normal bolus insulin, (2), a high-fat (HF) meal with normal bolus insulin and (3) a high-fat meal with normal bolus insulin with an additional 30% insulin bolus administered 3-h post-meal (HFA). Meals had identical carbohydrate and protein content and bolus insulin dose determined by carbohydrate-counting. Blood was sampled periodically for 6-h post-meal and analysed for triglyceride, non-esterified-fatty acids, apolipoprotein B48, glucagon, tumour necrosis factor alpha, fibrinogen, human tissue factor activity and plasminogen activator inhibitor-1. Continuous glucose monitoring captured interstitial glucose responses. Triglyceride concentrations following LF remained similar to baseline, whereas triglyceride levels following HF were significantly greater throughout the 6-h observation period. The additional insulin bolus (HFA) normalised triglyceride similarly to low fat 3-6 h following the meal. HF was associated with late postprandial elevations in tumour necrosis factor alpha, whereas LF and HFA was not. Fibrinogen, plasminogen activator inhibitor-1 and tissue factor pathway levels were similar between conditions. Additional bolus insulin 3 h following a high-carbohydrate high-fat meal prevents late rises in postprandial triglycerides and tumour necrosis factor alpha, thus improving cardiovascular risk profile.

  13. Accuracy of pencil-beam redefinition algorithm dose calculations in patient-like cylindrical phantoms for bolus electron conformal therapy.

    Science.gov (United States)

    Carver, Robert L; Hogstrom, Kenneth R; Chu, Connel; Fields, Robert S; Sprunger, Conrad P

    2013-07-01

    The purpose of this study was to document the improved accuracy of the pencil beam redefinition algorithm (PBRA) compared to the pencil beam algorithm (PBA) for bolus electron conformal therapy using cylindrical patient phantoms based on patient computed tomography (CT) scans of retromolar trigone and nose cancer. PBRA and PBA electron dose calculations were compared with measured dose in retromolar trigone and nose phantoms both with and without bolus. For the bolus treatment plans, a radiation oncologist outlined a planning target volume (PTV) on the central axis slice of the CT scan for each phantom. A bolus was designed using the planning.decimal(®) (p.d) software (.decimal, Inc., Sanford, FL) to conform the 90% dose line to the distal surface of the PTV. Dose measurements were taken with thermoluminescent dosimeters placed into predrilled holes. The Pinnacle(3) (Philips Healthcare, Andover, MD) treatment planning system was used to calculate PBA dose distributions. The PBRA dose distributions were calculated with an in-house C++ program. In order to accurately account for the phantom materials a table correlating CT number to relative electron stopping and scattering powers was compiled and used for both PBA and PBRA dose calculations. Accuracy was determined by comparing differences in measured and calculated dose, as well as distance to agreement for each measurement point. The measured doses had an average precision of 0.9%. For the retromolar trigone phantom, the PBRA dose calculations had an average ± 1σ dose difference (calculated - measured) of -0.65% ± 1.62% without the bolus and -0.20% ± 1.54% with the bolus. The PBA dose calculation had an average dose difference of 0.19% ± 3.27% without the bolus and -0.05% ± 3.14% with the bolus. For the nose phantom, the PBRA dose calculations had an average dose difference of 0.50% ± 3.06% without bolus and -0.18% ± 1.22% with the bolus. The PBA dose calculations had an average dose difference of 0.65%

  14. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  15. TU-H-CAMPUS-TeP1-05: Fast Processed 3D Printing-Aided Urethane Resin (PUR) Bolus in Radiation Therapy

    International Nuclear Information System (INIS)

    Zhao, B; Chiu, T; Gu, X; Lee, H; Nedzi, L; Jiang, S

    2016-01-01

    Purpose: 3D printed custom bolus is regularly used in radiation therapy clinic as a compensator. However, usual method of bolus printing with 100% filling is very time-consuming. The purpose of this study is to evaluate the feasibility and benefit of 3D printed bolus filled with UR. Methods: Two boluses were designed on nose (9e electrons) and ear (6× photons) for a head phantom in treatment planning system (TPS) to achieve dose coverage to the skin. The bolus structures (56–167cc) were converted to STereoLithographic (STL) model using an in-house developed algorithm and sent to a commercial fused deposition modeling (FDM) printer. Only shells were printed with polylactic acid (PLA) material. Liquid UR was then placed in a vacuum pump and slowly poured into the hollow bolus from its top opening. Liquid UR hardened in around half an hour. The phantom was rescanned with custom boluses attached and the dosimetry was compared with original design in TPS. Basic CT and dose properties were investigated. GaF films were irradiated to measure dose profile and output of several open photon and electron beams under solid water and UR slabs of same thicknesses. Results: CT number was 11.2±7.3 and 65.4±7.8, respectively for solid water(∼1.04g/cc) and UR(∼1.08g/cc). The output measurement at dmax for 6× was within 2% for the two materials. The relative dose profiles of the two materials above dmax show 94–99% Gamma analysis passing rates for both photons and electrons. Dose distributions with 3D PUR boluses maintained great coverage on the intended skin regions and resembled that with computer generated boluses. Manufacturing 3D PUR boluses was 3–4 times faster than 100% printed boluses. The efficiency significantly improves for larger boluses. Conclusion: The study suggests UR has similar dose responses as solid water. Making custom bolus with UR greatly increases clinical workflow efficiency.

  16. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

    International Nuclear Information System (INIS)

    Adibi, Atoosa; Shahbazi, Ali

    2014-01-01

    Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups. Forty-eight patients (23 males, 25 females, mean age=56.4±13.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P>0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase. The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients

  17. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    Science.gov (United States)

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Radiation dosimetry for bolus administration of oxygen-15-water

    International Nuclear Information System (INIS)

    Brihaye, C.; Depresseux, J.C.; Comar, D.

    1995-01-01

    The authors describe the development of a biokinetic model which permits an estimation of organ activities and the dosimetry of a bolus of 15 O-water. The aim of this study was to estimate time-activity functions and deduce the cumulated activities in different organs so that the radiation absorbed dose values can be estimated. The model used includes the right heart chambers, lungs, left heart chambers, brain, liver, kidneys, muscles, gasrointestinal tract and the remainder of the body. Activity in an organ will decay by physical decay with the decay constant, γ, and can diffuse in the organ. An exception is the heart, where blood is ejected from the heart chambers. Depending on the location of the organ in relation to the blood sampling point, organ activities can be calculated by convolution or deconvolution. The radiation absorbed dose values were estimated and an effective dose equivalent H E of 1.16 μSv/MBq (4.32 mrem/mCi) as well as an effective dose E of 1.15 μSv/MBq (4.25 mrem/mCi) were calculated. The cumulated activities in select organs measured by PET gave good agreement with the values calculated by this model. The values of effective dose equivalent and effective dose for bolus administration of 15 O-water calculated from the absorbed doses estimated by the proposed kinetic model are almost three times higher than those previously published. A total of 8700 MBq (235 mCi) of 15 O-water can be administered if an effective dose of 10 mSv (1 rem) is accepted. 32 refs., 5 figs., 2 tabs

  19. Three-dimensional printer-aided casting of soft, custom silicone boluses (SCSBs) for head and neck radiation therapy.

    Science.gov (United States)

    Chiu, Tsuicheng; Tan, Jun; Brenner, Mathew; Gu, Xuejun; Yang, Ming; Westover, Kenneth; Strom, Tobin; Sher, David; Jiang, Steve; Zhao, Bo

    Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy. We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed. Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy. Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  20. Transplantation tolerance in primates following total lymphoid irradiation and allogeneic bone marrow injection. II. Renal allographs

    International Nuclear Information System (INIS)

    Myburgh, J.A.; Smit, J.A.; Hill, R.R.H.; Browde, S.

    1980-01-01

    A modified regimen of fractionated total lymphoid irradiation and allogeneic bone marrow (BM) injection in chacma baboons produced transplantation tolerance for allografted kidneys from the BM donors, and substantial chimerism without evidence of graft-versus-host disease. Increasing the dose of nucleated BM cells injected 4-fold over that used in liver transplantation resulted consistently in normal graft function in the early weeks after transplantation. Bone marrow injection and challenge with renal allografts could be delayed for at least 3 weeks after completion of irradiation. If it can be shown that this period can be extended even further, the protocols will be relevant to the circumstances of clinical cadaveric renal transplantation

  1. Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography

    International Nuclear Information System (INIS)

    Kerl, J. Matthias; Bauer, Ralf W.; Renker, Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Schell, Boris; Larson, Maya Christina; Kromen, Wolfgang; Jacobi, Volkmar

    2011-01-01

    Purpose: Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. Methods and materials: Data of 120 patients who had undergone dual source dual energy CT pulmonary angiography for suspected acute pulmonary embolism were evaluated. Group 1 (n = 30) was scanned in craniocaudal direction using 64 × 0.6 mm collimation; groups 2–4 (n = 30 each) were scanned in caudocranial direction using 14 × 1.2 mm collimation. In groups 1–3 biphasic injection protocols with different amounts of CM and NaCl were investigated. In group 4 a split-bolus protocol with an initial CM bolus of 50 ml followed by 30 ml of a 70%:30% NaCl/CM mixture and a 50 ml NaCl chaser bolus was used. CT density values in the subclavian vein (SV), superior vena cava (SVC), pulmonary artery tree (PA), and the descending aorta (DA) were measured. Artifacts arising from the SV and SVC on DE pulmonary iodine distribution map were rated on a scale from 1 to 5 (1 = fully diagnostic; 5 = non-diagnostic) by two blinded readers. Results: In protocol 4 mean attenuation in the SV (645 ± 158 HU) and SVC (389 ± 114 HU) were significantly lower compared to groups 1–3 (p < 0.002). Artifacts in group 4 (1.1 ± 0.4 and 1.5 ± 0.7 for the SV and SVC, respectively) were rated significantly less severe compared to group 1 (3.2 ± 1.0 and 3.0 ± 1.1), 2 (2.6 ± 1.1 and 2.3 ± 1.0) and 3 (1.9 ± 0.9 and 1.9 ± 0.7) (p < 0.01 for all), whereas no significant difference was found between groups 1 and 2 for the subclavian vein (p = 0.07). Attenuation in the PA was also significantly lower in group 4 (282 ± 116 HU) compared to group 1 (397 ± 137 HU), group 2 (376 ± 115 HU) and group 3 (311 ± 104 HU), but still on a diagnostic level. Conclusion: Split-bolus injection provides sufficient attenuation for pulmonary DECT

  2. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect

    Science.gov (United States)

    Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz

    2016-01-01

    Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169

  3. Insulin Degludec/Insulin Aspart Administered Once Daily at Any Meal, With Insulin Aspart at Other Meals Versus a Standard Basal-Bolus Regimen in Patients With Type 1 Diabetes

    Science.gov (United States)

    Hirsch, Irl B.; Bode, Bruce; Courreges, Jean-Pierre; Dykiel, Patrik; Franek, Edward; Hermansen, Kjeld; King, Allen; Mersebach, Henriette; Davies, Melanie

    2012-01-01

    OBJECTIVE To evaluate efficacy and tolerability of a co-formulation of insulin degludec and insulin aspart (IDegAsp) with insulin aspart (IAsp) at other meals compared with basal-bolus therapy using insulin detemir (IDet) and IAsp. RESEARCH DESIGN AND METHODS Adults (n = 548) with type 1 diabetes (A1C 7.0–10.0%; BMI ≤35.0 kg/m2) were randomized 2:1 in a 26-week, multinational, parallel-group, treat-to-target trial to IDegAsp or IDet. IDegAsp was given with a meal, and IDet was given in the evening, with a second (breakfast) dose added if needed. RESULTS Non-inferiority for IDegAsp versus IDet was confirmed; A1C improved by 0.75% with IDegAsp and 0.70% with IDet to 7.6% in both groups (estimated treatment difference IDegAsp − IDet: –0.05% [95% CI –0.18 to 0.08]). There was no statistically significant difference between IDegAsp and IDet in the rates of severe hypoglycemia (0.33 and 0.42 episodes/patient-year, respectively) or overall confirmed (plasma glucose <3.1 mmol/L) hypoglycemia (39.17 and 44.34 episodes/patient-year, respectively). Nocturnal confirmed hypoglycemia rate was 37% lower with IDegAsp than IDet (3.71 vs. 5.72 episodes/patient-year, P < 0.05). Weight gain was 2.3 and 1.3 kg with IDegAsp and IDet, respectively (P < 0.05). Total insulin dose was 13% lower in the IDegAsp group (P < 0.0001). No treatment differences were detected in Health-Related Quality of Life, laboratory measurements, physical examination, vital signs, electrocardiograms, fundoscopy, or adverse events. CONCLUSIONS IDegAsp in basal-bolus therapy with IAsp at additional mealtimes improves overall glycemic control and was non-inferior to IDet, with a reduced risk of nocturnal hypoglycemia and fewer injections in comparison with IDet + IAsp basal-bolus therapy. PMID:22933438

  4. Efficacy study of Styplon Vet Bolus as supportive therapy in management of hemorrhagic conditions of ruminants

    Directory of Open Access Journals (Sweden)

    B R Ravikumar

    Full Text Available On-field trial was conducted in dairy animals to evaluate efficacy of Styplon Vet Bolus (M/s Himalaya Drug Company, Banglore, India as supportive therapy in management of hemorrhagic conditions (Hematuria, hemoagalectia, bleeding wounds, uterine bleeding and epistaxis of ruminants. Styplon Vet 1-2 boli twice daily was administered to cows and buffaloes, and ½ bolus twice daily for sheep till they recover clinically. The results indicated that Styplon Vet Bolus is a safe and effective styptic in ruminants. [Vet World 2009; 2(12.000: 470-471

  5. 21 CFR 520.1802b - Piperazine-carbon disulfide complex boluses.

    Science.gov (United States)

    2010-04-01

    ...) per 500 pounds body weight; removal of large strongyles, pinworms, and bots, 1 bolus per 250 pounds...), large strongyles (Strongylus spp.) bots (Gastrophilus spp.), small strongyles, and pinworms (Oxyuris...

  6. Optimization of initial propofol bolus dose for EEG Narcotrend Index-guided transition from sevoflurane induction to intravenous anesthesia in children.

    Science.gov (United States)

    Dennhardt, Nils; Boethig, Dietmar; Beck, Christiane; Heiderich, Sebastian; Boehne, Martin; Leffler, Andreas; Schultz, Barbara; Sümpelmann, Robert

    2017-04-01

    Sevoflurane induction followed by intravenous anesthesia is a widely used technique to combine the benefits of an easier and less traumatic venipuncture after sevoflurane inhalation with a recovery with less agitation, nausea, and vomiting after total intravenous anesthesia (TIVA). Combination of two different anesthetics may lead to unwanted burst suppression in the electroencephalogram (EEG) during the transition phase. The objective of this prospective clinical observational study was to identify the optimal initial propofol bolus dose for a smooth transition from sevoflurane induction to TIVA using the EEG Narcotrend Index (NI). Fifty children aged 1-8 years scheduled for elective pediatric surgery were studied. After sevoflurane induction and establishing of an intravenous access, a propofol bolus dose range 0-5 mg·kg -1 was administered at the attending anesthetist's discretion to maintain a NI between 20 and 64, and sevoflurane was stopped. Anesthesia was continued as TIVA with a propofol infusion dose of 15 mg·kg -1 ·h -1 for the first 15 min, followed by stepwise reduction according to McFarlan's pediatric infusion regime, and remifentanil 0.25 μg·kg -1 ·min -1 . Endtidal concentration of sevoflurane, NI, and hemodynamic data were recorded during the whole study period using a standardized case report form. Propofol plasma concentrations were calculated using the paedfusor dataset and a TIVA simulation program. Median endtidal concentration of sevoflurane at the time of administration of the propofol bolus was 5.1 [IQR 4.7-5.9] Vol%. The median propofol bolus dose was 1.2 [IQR 0.9-2.5] mg·kg -1 and median NI thereafter was 33 [IQR 23-40]. Nine children presented with a NI 13-20 and three children with burst suppression in the EEG (NI 0-12); all of them received an initial propofol bolus dose >2 mg·kg -1 . Regression equation demonstrated that NI 20-64 was achieved with a 95% probability when using a propofol bolus dose of 1 mg·kg -1 after

  7. One year results of preoperative single bolus ATG-Fresenius induction therapy in sensitized renal transplant recipients.

    Science.gov (United States)

    Wang, D; Chen, J H; Wu, W Z; Yang, S L; Wu, G J; Wang, H; Tan, J M

    2007-01-01

    Sensitization in kidney transplantation is associated with more acute rejections, inferior graft survival, and an increase in delayed graft function. This study was designed to evaluate the efficacy and safety of preoperative single bolus antithymocyte globulin (ATG) induction therapy in sensitized renal transplant recipients. Fifty-six cadaveric donor kidney transplant recipients were divided into two groups: Group I (nonsensitized group, n = 30) and group II (sensitized group, PRA>10%, n = 26). ATG was given as a single preoperative bolus induction therapy to group II (ATG IV; 9 mg/kg). The group I patients were treated with mycophenolate mofetil preoperatively as induction therapy. The basic immunosuppressive regimen included tacrolimus (FK-506) or cyclosporine, mycophenolate mofetil, and prednisolone. After hospital discharge, patients were followed on a routine outpatient basis for 12 months. Acute rejection episodes (ARE) occurred in 20% (6/30) of group I and 15.38% (4/26) of group II patients (P = NS). Infections occurred in eight patients (26.7%) as 11 episodes (36.7%), averaging 1.4 episodes per infected patient in group 1, and 6 patients (23.1%) for a total of 10 episodes (38.5%), averaging 1.7 episodes per infected patient, in group II (P = NS). Occurrence of side effects and hospital stay were almost comparable in the two groups. No delayed graft function was observed in either group. The 12-month actuarial patient and graft survival were 100% in Group I and II. A preoperative single bolus ATG induction therapy was an effective and safe therapeutic measure, yielding an acceptable acute rejection rate in presensitized renal transplant recipients.

  8. Stability of total nutrient admixtures with lipid injectable emulsions in glass versus plastic packaging.

    Science.gov (United States)

    Driscoll, David F; Silvestri, Anthony P; Bistrian, Bruce R; Mikrut, Bernard A

    2007-02-15

    The physical stability of two emulsions compounded as part of a total nutrient admixture (TNA) was studied in lipids packaged in either glass or plastic containers. Five weight-based adult TNA formulations that were designed to meet the full nutritional needs of adults with body weights between 40 and 80 kg were studied. Triplicate preparations of each TNA were assessed over 30 hours at room temperature by applying currently proposed United States Pharmacopeia (USP) criteria for mean droplet diameter, large-diameter tail, and globule-size distribution (GSD) for lipid injectable emulsions. In accordance with conditions set forth in USP chapter 729, the higher levels of volume-weighted percent of fat exceeding 5 microm (PFAT(5)) should not exceed 0.05% of the total lipid concentration. Significant differences were noted among TNA admixtures based on whether the lipid emulsion product was manufactured in glass or plastic. The plastic-contained TNAs failed the proposed USP methods for large-diameter fat globules in all formulations from the outset, and 60% had significant growth in large-diameter fat globules over time. In contrast, glass-contained TNAs were stable throughout and in all cases would have passed proposed USP limits. Certain lipid injectable emulsions packaged in plastic containers have baseline abnormal GSD profiles compared with those packaged in glass containers. When used to compound TNAs, the abnormal profile worsens and produces less stable TNAs than those compounded with lipid injectable emulsions packaged in glass containers.

  9. Functional aspects of distal oesophageal spasm: the role of onset velocity and contraction amplitude on bolus transit

    Science.gov (United States)

    Pohl, Daniel; Ciolino, Jody; Roberts, Jason; Savarino, Edoardo; Freeman, Janice; Nietert, Paul J; Tutuian, Radu; Castell, Donald

    2012-01-01

    Background Distal oesophageal spasm (DES) is a rare and under-investigated motility abnormality. Recent studies indicate effective bolus transit in varying percentages of DES patients. Aim Explore functional aspects including contraction onset velocity and contraction amplitude cut-off values for simultaneous contractions to predict complete bolus transit Methods We re-examined data from 107 impedance-manometry recordings with a diagnosis of DES. Receiver operating characteristic (ROC) analysis was conducted, regarding effects of onset velocity on bolus transit taking into account distal oesophageal amplitude (DEA) and correcting for intra-individual repeated measures. Results Mean area under the ROC curve for saline and viscous swallows were 0.84±0.05 and 0.84±0.04, respectively. Velocity criteria of >30cm/s when DEA>100mmHg and 8cm/s when DEADEA>100mmHg and >7cm/s when DEAsensitivity of 75% and specificity of 80% to identify complete bolus transit. Using these criteria, final diagnosis changed in 44.9% of patients. Abnormal bolus transit was observed in 50.9% of newly diagnosed DES patients versus 7.5% of patients classified as normal. DES patients with DEA>100mmHg suffered twice as often from chest pain than those with DEA<100mmHg. Conclusion The proposed velocity cut-offs for diagnosing distal oesophageal spasm improve the ability to identify patients with spasm and abnormal bolus transit. PMID:22475443

  10. Randomized Clinical Trial of Periarticular Drug Injection used in combination Patient-Controlled Analgesia versus Patient-Controlled Analgesia Alone in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    MN Sabran

    2008-11-01

    Full Text Available This is a prospective randomized clinical trial to compare use of a combination of periarticular drug injection with patient- controlled analgesia (PCA to PCA alone in post-total knee arthroplasty (TKA. Thirty patients who were admitted for unilateral total knee arthroplasty were selected randomly into an Injection group or a Standard group. The periarticular injection contained Ropivacaine, Ketorolac and Adrenaline, given intra-operatively. The mean amount of opioid used was 22.87 mmol/L in the Injection group as compared to 39.78 mmol/L in the Standard group (p = 0.026. The Injection group had lower pain score at rest and during exercise (p=0.021, p=0.041, respectively, as well as better return to function (p=0.026 and shorter hospital stay (6.1 days, Injection; 7.5 days, Standard, p=0.027. Overall, the group receiving periarticular drugs injection had less pain, less narcotic usage, earlier return to function, similar experience of adverse effects and shorter hospital stays.

  11. Nonlinear pharmacokinetics of visnagin in rats after intravenous bolus administration.

    Science.gov (United States)

    Haug, Karin G; Weber, Benjamin; Hochhaus, Guenther; Butterweck, Veronika

    2012-01-23

    Ammi visnaga L. (syn. Khella, Apiaceae) preparations have traditionally been used in the Middle East for the treatment of kidney stone disease. Visnagin, a furanocoumarin derivative, is one of the main compounds of Ammi visnaga with potential effects on kidney stone prevention. To date, no information is available about the pharmacokinetic (PK) properties of visnagin. It was the aim of the study to characterize the PK properties of visnagin after intravenous (i.v.) bolus administration in rats and to develop an adequate model for the description of the observed data, including model parameter estimates. Therefore, three doses of visnagin (1.25, 2.5, and 5mg/kg) solubilized in 25% Captisol® were administered by i.v. bolus injection to male Sprague-Dawley rats. Plasma samples were extracted and subsequently analyzed using a validated LC-MS/MS method. Both non-compartmental and compartmental PK analyses were performed. A stepwise model building approach was applied including nonlinear mixed effect modeling for final model selection and to obtain final model estimates in NONMEM VI. The average areas under the curve (AUC(0-last)) after doses of 1.25, 2.5, and 5mg/kg were 1.03, 3.61, and 12.6 mg *h/l, respectively. The shape of the plasma concentration-time profiles and the observed disproportionate increase in AUC(0-last) with increasing dose suggested nonlinearity in the elimination of visnagin. A two-compartment Michaelis-Menten model provided the best fit with following typical values of the parameter estimates: 2.09 mg/(l*h) (V(max)), 0.08 mg/l (K(M)), 0.175 l (V(C)), 1.0 h⁻¹ (k₁₂), and 1.22 h⁻¹ (k₂₁). Associated inter-subject variability estimates (% CV) for V(max), K(M) and V(C) were 21.8, 70.9, and 9.2, respectively. Intra-subject variability (constant CV error model) was estimated to be 7.0%. The results suggest the involvement of a saturable process in the elimination of visnagin, possibly an enzyme or transporter system. Copyright © 2011

  12. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  13. Review article : intra-oesophageal impedance monitoring for the assessment of bolus transit and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Conchillo, J. M.; Smout, A. J.

    2009-01-01

    Background Intra-oesophageal impedance monitoring can be used to assess the clearance of a swallowed bolus (oesophageal transit) and to detect gastro-oesophageal reflux independent of its acidity. Aim To discuss the clinical application of the impedance technique for the assessment of bolus transit

  14. The Efficacy of Programmed Intermittent Epidural Bolus for Postoperative Analgesia after Open Gynecological Surgery: A Randomized Double-Blinded Study

    Directory of Open Access Journals (Sweden)

    Shiho Satomi

    2018-01-01

    Full Text Available Background. It is well known that the programmed intermittent epidural bolus (PIEB technique effectively provides epidural anesthesia in labor. This randomized double-blind trial compared the postoperative analgesic efficacy of PIEB with that of continuous epidural infusion (CEI in patients undergoing gynecological surgery under combined general-epidural anesthesia. Methods. Patients undergoing open gynecological surgery under combined general-epidural anesthesia were randomized at a 1 : 1 ratio to receive PIEB or CEI. In the PIEB group, the pump delivered 4 mL ropivacaine 0.2% plus fentanyl 2 μg/mL every hour. In the CEI group, the pump delivered the same solution at a rate of 4 mL/h. In both groups, additional 4 mL boluses of ropivacaine 0.2% plus fentanyl 2 μg/mL were provided, when necessary, by patient-controlled epidural analgesia after surgery. The primary outcome was the total ropivacaine dose 40 hours after surgery. The secondary outcomes were the number of PCEA boluses and postoperative pain (evaluated on an 11-point numerical rating scale 3, 24, and 48 hours after surgery. Results. In total, 57 patients were randomized (n=28 and 29 in the PIEB and CEI groups, resp.. The two groups differ significantly in terms of the total ropivacaine dose 40 hours after surgery (mean (standard deviation: 155.38 (4.55 versus 159.73 (7.87 mL, P=0.016. Compared to the CEI group, the PIEB group had significantly lower numerical rating scale scores 3 hours (median [lower–upper quartiles]: 0 [0–0.5] versus 3 [0–5.5], P=0.002, 24 hours (1 [0–2] versus 3 [1–4], P=0.003, and 48 hours (1 [0–2] versus 2 [2–3.5], P=0.002 after surgery. Conclusion. PIEB was better than CEI in terms of providing postoperative analgesia after open gynecological surgery under combined general-epidural anesthesia.

  15. Do intra-articular hyaluronic acid injections delay total knee replacement in patients with osteoarthritis – A Cox model analysis

    Science.gov (United States)

    Amor, Bernard; Bardoulat, Isabelle; Tetafort, Aymeric; Pelletier-Fleury, Nathalie

    2017-01-01

    Due to the growing worldwide prevalence of knee osteoarthritis, the optimal management of this issue is critical for reducing its burden. Objectives This study aimed to describe patients treated for knee osteoarthritis between 2006 and 2013 in France and to compare the delay from diagnosis to total knee replacement between patients who received intra-articular hyaluronic acid injections and those who did not receive the injections. A second objective was to compare direct medical costs for ambulatory care between treatment groups. Materials and methods Patients were selected from a representative sample of the real world administrative claims database using an algorithm developed by experts from the scientific committee of the study. Data were matched with the medico-administrative database for hospital care. A Cox proportional hazards model was stratified for the treatment group and adjusted for available socio-demographic and medical covariates to compare restricted mean survival times at different time points (1, 3, 5 and 7.5 years) between groups. Costs were expressed in 2013 euros. Results A total of 14,782 patients were treated for knee osteoarthritis (67% women; mean age = 68 years). Among this population, 1,662 patients had total knee replacement (11.2%). At each time point, restricted mean survival time without total knee replacement was significantly higher (p-valueshyaluronic acid group, from +51 to +217 days at 1 and 7.5 years, respectively. For the year preceding total knee replacement, the means for total direct medical costs were similar between groups, €744 vs €805 for treatment and control groups, respectively, (p-value = 0.104). Intra-articular injections accounted for less than 10% of the total costs. Conclusion This is the first retrospective longitudinal study involving knee osteoarthritis patients using medico-administrative databases in France. The results support the effectiveness of hyaluronic acid injections in delaying total knee

  16. Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography.

    Science.gov (United States)

    Mihl, Casper; Kok, Madeleine; Altintas, Sibel; Kietselaer, Bas L J H; Turek, Jakub; Wildberger, Joachim E; Das, Marco

    2016-04-01

    Contrast media (CM) injection protocols should be customized to the individual patient. Aim of this study was to determine if software tailored CM injections result in diagnostic enhancement of the coronary arteries in computed tomography angiography (CTA) and if attenuation values were comparable between different weight categories. 265 consecutive patients referred for routine coronary CTA were scanned on a 2nd generation dual-source CT. Group 1 (n=141) received an individual CM bolus based on weight categories (39-59 kg; 60-74 kg; 75-94 kg; 95-109 kg) and scan duration ('high-pitch: 1s; "dual-step prospective triggering": 7s), as determined by contrast injection software (Certegra™ P3T, Bayer, Berlin, Germany). Group 2 (n=124) received a standard fixed CM bolus; Iopromide 300 mgI/ml; volume: 75 ml; flow rate: 7.2 ml/s. Contrast enhancement was measured in all proximal and distal coronary segments. Subjective and objective image quality was evaluated. Statistical analysis was performed using SPSS (IBM, version 20.0). For group 1, mean attenuation values of all segments were diagnostic (>325 HU) without statistical significant differences between different weight categories (p>0.17), proximal vs. distal: 449 ± 65-373 ± 58 HU (39-59 kg); 443 ± 69-367 ± 81 HU (60-74 kg); 427 ± 59-370 ± 61 HU (75-94 kg); 427 ± 73-347 ± 61 HU (95-109 kg). Mean CM volumes were: 55 ± 6 ml (39-59 kg); 61 ± 7 ml (60-74 kg); 71 ± 8 ml (75-94 kg); 84 ± 9 ml (95-109 kg). For group 2, mean attenuation values were not all diagnostic with differences between weight categories (p<0.01), proximal vs. distal: 611 ± 142-408 ± 69 HU (39-59 kg); 562 ± 135-389 ± 98 HU (60-74 kg); 481 ± 83-329 ± 81 HU (75-94 kg); 420 ± 73-305 ± 35 HU (95-109 kg). Comparable image noise and image quality were found between groups (p ≥ 0.330). Individually tailored CM injection protocols yield diagnostic attenuation and a more homogeneous enhancement pattern between different weight groups. CM

  17. Contrast timing in computed tomography: Effect of different contrast media concentrations on bolus geometry

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Jost, Gregor; Seidensticker, Peter; Kuhl, Christiane; Pietsch, Hubertus

    2012-01-01

    Objective: To assess the effect of low-osmolar, monomeric contrast media with different iodine concentrations on bolus shape in aortic CT angiography. Materials and methods: Repeated sequential computed tomography scanning of the descending aorta of eight beagle dogs (5 male, 12.7 ± 3.1 kg) was performed without table movement with a standardized CT scan protocol. Iopromide 300 (300 mg I/mL), iopromide 370 (370 mg I/mL) and iomeprol 400 (400 mg I/mL) were administered via a foreleg vein with an identical iodine delivery rate of 1.2 g I/s and a total iodine dose of 300 mg I/kg body weight. Time-enhancement curves were computed and analyzed. Results: Iopromide 300 showed the highest peak enhancement (445.2 ± 89.1 HU), steepest up-slope (104.2 ± 17.5 HU/s) and smallest full width at half maximum (FWHM; 5.8 ± 1.0 s). Peak enhancement, duration of FWHM, enhancement at FWHM and up-slope differed significantly between iopromide 300 and iomeprol 400 (p 0.05). Conclusions: Low viscous iopromide 300 results in a better defined bolus with a significantly higher peak enhancement, steeper up-slope and smaller FWHM when compared to iomeprol 400. These characteristics potentially affect contrast timing.

  18. Dextrose boluses versus burette dextrose infusions in prevention of ...

    African Journals Online (AJOL)

    The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the ... and safety monitoring board (DSMB) was set up to oversee to ..... On the other hand, Namukwaya et al in a prospective study at Mulago ...

  19. Impacts of palatal coverage on bolus formation during mastication and swallowing and subsequent adaptive changes.

    Science.gov (United States)

    Sato, T; Furuya, J; Tamada, Y; Kondo, H

    2013-10-01

    Palatal coverage is often required for elderly edentulous patients with complete dentures. The purpose of this study was to clarify impacts of palatal coverage on bolus formation and subsequent adaptive changes. Subjects were 18 healthy young dentulous adults who wore 1·5-mm-thick palatal plates. Subjects were asked to feed 12 g of bicoloured rice as usual, and the bolus formation by mastication and swallowing in the pharynx was observed using a nasal videoendoscopy. The bolus formation index (BFI), number of mastication strokes until swallowing, visual analogue scale about swallowing easiness and masticatory performance using colour-changeable gum were measured under three conditions: before placement of the palatal plate (day 0), immediately after placement (day 1) and after 7 days of wearing the plate (day 7). BFI and visual analogue scale on day 1 were significantly lower than those on day 0, but those on day 7 significantly recovered to the level of day 0. The number of mastication strokes did not change from day 0 to day 1, however, that on day 7 was significantly higher. Masticatory performance on days 1 and 7 was significantly lower than that on day 0. Although palatal coverage inhibits bolus formation during feeding, subjects increased the number of mastication strokes until swallowing threshold as they adapted to palatal coverage over time. This adaptive change was due to compensate for the lowered masticatory performance to achieve bolus formation for comfortable swallowing. © 2013 John Wiley & Sons Ltd.

  20. A Three-arm Randomized Clinical Trial Comparing Continuous Femoral Plus Single-injection Sciatic Peripheral Nerve Blocks versus Periarticular Injection with Ropivacaine or Liposomal Bupivacaine for Patients Undergoing Total Knee Arthroplasty.

    Science.gov (United States)

    Amundson, Adam W; Johnson, Rebecca L; Abdel, Matthew P; Mantilla, Carlos B; Panchamia, Jason K; Taunton, Michael J; Kralovec, Michael E; Hebl, James R; Schroeder, Darrell R; Pagnano, Mark W; Kopp, Sandra L

    2017-06-01

    Multimodal analgesia is standard practice for total knee arthroplasty; however, the role of regional techniques in improved perioperative outcomes remains unknown. The authors hypothesized that peripheral nerve blockade would result in lower pain scores and opioid consumption than two competing periarticular injection solutions. This three-arm, nonblinded trial randomized 165 adults undergoing unilateral primary total knee arthroplasty to receive (1) femoral catheter plus sciatic nerve blocks, (2) ropivacaine-based periarticular injection, or (3) liposomal bupivacaine-based periarticular injection. Primary outcome was maximal pain during postoperative day 1 (0 to 10, numerical pain rating scale) in intention-to-treat analysis. Additional outcomes included pain scores and opioid consumption for postoperative days 0 to 2 and 3 months. One hundred fifty-seven study patients received peripheral nerve block (n = 50), ropivacaine (n = 55), or liposomal bupivacaine (n = 52) and reported median maximal pain scores on postoperative day 1 of 3, 4, and 4.5 and on postoperative day 0 of 1, 4, and 5, respectively (average pain scores for postoperative day 0: 0.6, 1.7, and 2.4 and postoperative day 1: 2.5, 3.5, and 3.7). Postoperative day 1 median maximal pain scores were significantly lower for peripheral nerve blockade compared to liposomal bupivacaine-based periarticular injection (P = 0.016; Hodges-Lehmann median difference [95% CI] = -1 [-2 to 0]). After postanesthesia care unit discharge, postoperative day 0 median maximal and average pain scores were significantly lower for peripheral nerve block compared to both periarticular injections (ropivacaine: maximal -2 [-3 to -1]; P bupivacaine: maximal -3 [-4 to -2]; P bupivacaine over ropivacaine in periarticular injections for total knee arthroplasty.

  1. SU-F-T-442: Dose Distribution Comparison for Post-Laryngectomy Stoma Area Between Conventional AP and VMAT Plans with Or Without Bolus

    Energy Technology Data Exchange (ETDEWEB)

    Lee, B [University of California, Los Angeles, Los Angeles, CA (United States); Zhang, J; Cho-Lim, J [VA Long Beach Healthcare System, Long Beach, CA (United States); University of California, Irvine, Orange, CA (United States); Leu, M [VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Inouye, W [VA Long Beach Healthcare System, Long Beach, CA (United States); Lorentz, W [University of California, Los Angeles, Los Angeles, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States); Lee, S [University of California, Los Angeles, Los Angeles, CA (United States); VA Long Beach Healthcare System, Long Beach, CA (United States); VA Greater Los Angeles Healthcare System, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To compare dose distributions of conventional AP vs. VMAT treatment plans with or without bolus around post-laryngectomy stoma. Methods: Radiation dose coverage for post-laryngectomy stoma was analyzed using a set of real-case CT-simulation images. After meticulous contouring of the catheter cuff, stoma lumen, peri-stoma skin and subclinical tumor bed at the larynx, the resulting dosimetry plans were analyzed with or without a 5 mm bolus placement. Wet gauze was used to minimize the effect of any air gap. Four plans were generated: AP superclavicular (SCV) plan with or without bolus, and VMAT plan with or without bolus. A dose of 60Gy in 30 fractions was prescribed at 3 cm depth for AP SCV plan, and to 95% of the PTV volume for VMAT plan. Results: For the conventional AP SCV plan, the peri-stoma skin dose is sensitive to bolus placement as well as air gap compensation by wetted gauze (V95% of 20.7%, 33.0% and 94.8% for no bolus, bolus without and with air gap compensation, respectively). For stoma lumen, the dose drops off rapidly in depth. The catheter cuff may have certain dose-buildup effect, but air gap around it and under the bolus placed can pose a more serious problem. The dose distributions of the two VMAT plans are moderately different for peri-stoma skin (V95% of 95.0% with bolus and air gap compensation, and 82.3% without bolus), but nearly identical for stoma lumen (V95% of 91.5% and 92.0%, respectively). VMAT allows beamlets with different angles of incidence that helped achieve such dose distribution around the stoma even without bolus placement. Conclusion: Overall, the dose coverage around the stoma in the VMAT plan is better than the conventional AP SCV plan. To achieve optimal dose distribution, it is still recommended to place physical bolus and reduce the air gaps.

  2. Causes of death after fluid bolus resuscitation: new insights from FEAST.

    Science.gov (United States)

    Myburgh, John; Finfer, Simon

    2013-03-14

    The Fluid Expansion as Supportive Therapy (FEAST study) was an extremely well conducted study that gave unexpected results. The investigators had reported that febrile children with impaired perfusion treated in low-income countries without access to intensive care are more likely to die if they receive bolus resuscitation with albumin or saline compared with no bolus resuscitation at all. In a secondary analysis of the trial, published in BMC Medicine, the authors found that increased mortality was evident in patients who presented with clinical features of severe shock in isolation or in conjunction with features of respiratory or neurological failure. The cause of excess deaths was primarily refractory shock and not fluid overload. These features are consistent with a potential cardiotoxic or ischemia-reperfusion injury following resuscitation with boluses of intravenous fluid. Although these effects may have been amplified by the absence of invasive monitoring, mechanical ventilation or vasopressors, the results provide compelling insights into the effects of intravenous fluid resuscitation and potential adverse effects that extend beyond the initial resuscitation period. These data add to the increasing body of literature about the safety and efficacy of intravenous resuscitation fluids, which may be applicable to management of other populations of critically ill patients.

  3. Therapeutic efficacy and toxicity of bolus application of chemotherapy protocol in the treatment of metastatic colorectal cancer.

    Science.gov (United States)

    Šišić, Ibrahim; Pojskić, Belma; Mekić Abazović, Alma; Kovčin, Vladimir

    2015-08-01

    To compare efficacy and toxicity of bolus application of chemotherapy protocol, oxaliplatin, fluorouracil (bolus), leucovorin (folfox) between two groups of patients in the therapy of metastatic colorectal carcinoma (mCRC). A total of 63 patients were treated for mCRC in the period January 2009 - January 2010 at the Department of Oncology of the Cantonal Hospital Zenica, Bosnia and Herzegovina (first group, 30 patients) and at the Department of Oncology of the Clinical Hospital Centre Bežanijska kosa in Belgrade, Serbia, in the period January 2005 - January 2006 (second group, 33 patients). The patients were treated according the same protocol, i.v. bolus infusion, but in different day intervals (D), 1, 8, 15/28 days or D1-D5/28 days, respectively. In all patients the following factors were analyzed: tumor response, overall survival (OS), progression free survival, hematological and non-hematological toxicity . Colon was the primary localization in almost two thirds of patients. There was no statistically significant difference between the groups according to the age, hematological and non-hematological toxicity, as well as in achieved OS. Progression free survival expressed in months was in average 5 months though with a large range between minimal and maximal survival time. Both groups have shown equivalent efficacy to applied chemotherapy protocols. Overall survival in the two groups matched data from the literature. Further research should confirm success of the combination of chemotherapy protocols and their combination with the biological therapy. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  4. Therapeutic efficacy and toxicity of bolus application of chemotherapy protocol in the treatment of metastatic colorectal cancer

    Directory of Open Access Journals (Sweden)

    Ibrahim Šišić

    2015-08-01

    Full Text Available Aim To compare efficacy and toxicity of bolus application of chemotherapy protocol, oxaliplatin, fluorouracil (bolus, leucovorin (folfox between two groups of patients in the therapy of metastatic colorectal carcinoma (mCRC. Methods A total of 63 patients were treated for mCRC in the period January 2009 – January 2010 at the Department of Oncology of the Cantonal Hospital Zenica, Bosnia and Herzegovina (first group, 30 patients and at the Department of Oncology of the Clinical Hospital Centre Bežanijska kosa in Belgrade, Serbia, in the period January 2005 – January 2006 (second group, 33 patients. The patients were treated according the same protocol, i.v. bolus infusion, but in different day intervals (D, 1, 8, 15/28 days or D1-D5/28 days, respectively. In all patients the following factors were analyzed: tumor response, overall survival (OS, progression free survival, hematological and non-hematological toxicity. Results Colon was the primary localization in almost two thirds of patients. There was no statistically significant difference between the groups according to the age, hematological and non-hematological toxicity, as well as in achieved OS. Progression free survival expressed in months was in average 5 months though with a large range between minimal and maximal survival time. Conclusion Both groups have shown equivalent efficacy to applied chemotherapy protocols. Overall survival in the two groups matched data from the literature. Further research should confirm success of the combination of chemotherapy protocols and their combination with the biological therapy.

  5. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    Full Text Available Abstract Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 µg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2 µg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B - Ropivacaine 0.1% plus Sufentanil 0.2 µg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes.

  6. The impact of injector-based contrast agent administration in time-resolved MRA.

    Science.gov (United States)

    Budjan, Johannes; Attenberger, Ulrike I; Schoenberg, Stefan O; Pietsch, Hubertus; Jost, Gregor

    2018-05-01

    Time-resolved contrast-enhanced MR angiography (4D-MRA), which allows the simultaneous visualization of the vasculature and blood-flow dynamics, is widely used in clinical routine. In this study, the impact of two different contrast agent injection methods on 4D-MRA was examined in a controlled, standardized setting in an animal model. Six anesthetized Goettingen minipigs underwent two identical 4D-MRA examinations at 1.5 T in a single session. The contrast agent (0.1 mmol/kg body weight gadobutrol, followed by 20 ml saline) was injected using either manual injection or an automated injection system. A quantitative comparison of vascular signal enhancement and quantitative renal perfusion analyses were performed. Analysis of signal enhancement revealed higher peak enhancements and shorter time to peak intervals for the automated injection. Significantly different bolus shapes were found: automated injection resulted in a compact first-pass bolus shape clearly separated from the recirculation while manual injection resulted in a disrupted first-pass bolus with two peaks. In the quantitative perfusion analyses, statistically significant differences in plasma flow values were found between the injection methods. The results of both qualitative and quantitative 4D-MRA depend on the contrast agent injection method, with automated injection providing more defined bolus shapes and more standardized examination protocols. • Automated and manual contrast agent injection result in different bolus shapes in 4D-MRA. • Manual injection results in an undefined and interrupted bolus with two peaks. • Automated injection provides more defined bolus shapes. • Automated injection can lead to more standardized examination protocols.

  7. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  8. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    International Nuclear Information System (INIS)

    Liu, W; Kenneth, R; Higgins, S; Nath, R; Zhu, D; Trumpore, S; Chen, Z

    2016-01-01

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  9. SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

    Energy Technology Data Exchange (ETDEWEB)

    Liu, W; Kenneth, R; Higgins, S; Nath, R [Yale University School of Medicine, New Haven, CT (United States); Zhu, D [Saint Thomas Hospital, Murfreesboro, TN (United States); Trumpore, S [Yale-New Haven Hospital, New Haven, CT (United States); Chen, Z [Yale New Haven Hospital, New Haven, CT (United States)

    2016-06-15

    Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

  10. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  11. Radionuclide esophageal transit of a liquid bolus: A reappraisal

    International Nuclear Information System (INIS)

    Holloway, R.H.; Lange, R.C.; Magyar, L.; Greene, R.; McCallum, R.W.

    1984-01-01

    Measurement of radionuclide esophageal transit (RT) using a liquid bolus has been suggested as a screening test for esophageal motor disorders (EMD). The authors prospectively evaluated RT in 49 patients referred for esophageal manometry. Ten subjects with normal manometry served as controls. RT was performed using two 10 ml boluses of water labeled with 250 μCi /sup 99m/Tc-sulfur colloid. Patients were studied supine and the swallow sequences framed in 1 second intervals. Transit time was measured from the time of entry to the time of exit from the esophagus. Mean transit time in normal subjects was 9.1 +- 2.1 (SD) sec. The test was abnormal if the transit time was prolonged (> 15 sec) in at least 1 of 2 swallows. RT agreed with manometry in 36/49 patients (75%), including 9/9 achalasics, 3/3 diffuse esophageal spasm, 3/7 'nutcracker esophagus' and 7/8 non-specific motor disorders (NSMD). 4/18 patients with normal manometry had abnormal RT. 9/31 patients with abnormal manometry had normal RT, including 4/7 nutcracker esophagus, 3/3 hypertrensive LES, 1/1 scleroderma and 1/8 NSMD. Sensitivity of RT was 70% and specificity 77%. The false positive rate was 15% and the false negative rate 39%. The authors conclude the following: 1) RT identifies patients with absent or impaired peristalsis; 2) There is substantial incidence of false negatives among patients with manometric disorders but normal peristalsis; and 3) Abnormal RT did occur in some patients with normal menometry. RT using a liquid bolus may not be sensitive enough as a screening test for EMD, but it may be an important adjunct to manometry

  12. Ocular Dynamics of Bolus Ingestion of Eleis guineensis Sap (Palm ...

    African Journals Online (AJOL)

    Elaeis guineensis), and is widely consumed among the various ethnic nationalities in Nigeria. The effect of bolus ingestion of 600ml, palm wine was undertaken so as to determine its ocular dynamics in healthy volunteers. Results showed that ...

  13. Total motile sperm count has a superior predictive value over the WHO 2010 cut-off values for the outcomes of intracytoplasmic sperm injection cycles.

    Science.gov (United States)

    Borges, E; Setti, A S; Braga, D P A F; Figueira, R C S; Iaconelli, A

    2016-09-01

    The objective of this study was to compare (i) the intracytoplasmic sperm injection outcomes among groups with different total motile sperm count ranges, (ii) the intracytoplasmic sperm injection outcomes between groups with normal and abnormal total motile sperm count, and (iii) the predictive values of WHO 2010 cut-off values and pre-wash total motile sperm count for the intracytoplasmic sperm injection outcomes, in couples with male infertility. This study included data from 518 patients undergoing their first intracytoplasmic sperm injection cycle as a result of male infertility. Couples were divided into five groups according to their total motile sperm count: Group I, total motile sperm count sperm count 1-5 × 10(6) ; group III, total motile sperm count 5-10 × 10(6) ; group IV, total motile sperm count 10-20 × 10(6) ; and group V, total motile sperm count >20 × 10(6) (which was considered a normal total motile sperm count value). Then, couples were grouped into an abnormal and normal total motile sperm count group. The groups were compared regarding intracytoplasmic sperm injection outcomes. The predictive values of WHO 2010 cut-off values and total motile sperm count for the intracytoplasmic sperm injection outcomes were also investigated. The fertilization rate was lower in total motile sperm count group I compared to total motile sperm count group V (72.5 ± 17.6 vs. 84.9 ± 14.4, p = 0.011). The normal total motile sperm count group had a higher fertilization rate (84.9 ± 14.4 vs. 81.1 ± 15.8, p = 0.016) and lower miscarriage rate (17.9% vs. 29.5%, p = 0.041) compared to the abnormal total motile sperm count group. The total motile sperm count was the only parameter that demonstrated a predictive value for the formation of high-quality embryos on D2 (OR: 1.18, p = 0.013), formation of high-quality embryos on D3 (OR: 1.12, p = 0.037), formation of blastocysts on D5 (OR: 1.16, p = 0.011), blastocyst expansion grade on D5

  14. Comparison of first-pass and second-bolus dynamic susceptibility perfusion MRI in brain tumors

    International Nuclear Information System (INIS)

    Spampinato, M.V.; Besenski, Nada; Rumboldt, Zoran; Wooten, Caroline; Dorlon, Margaret

    2006-01-01

    Our goal was to evaluate whether the T1 shortening effect caused by contrast leakage into brain tumors, a well-known confounding effect in the quantification of relative cerebral blood volume (rCBV) measurements, may be corrected by the administration of a predose of gadolinium-DTPA. As part of their presurgical imaging protocol, 25 patients with primary brain tumors underwent two consecutive dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion MR studies. Intratumoral rCBV measurements and normalized rCBV values obtained during the first-pass and second-bolus studies were compared (Wilcoxon signed-ranks test). The frequency of relatively increased rCBV ratios on the second-bolus study was compared between enhancing and non-enhancing neoplasms (Fisher's exact test). Postprocessing perfusion studies were evaluated for image quality on a scale of 0-3 (Wilcoxon signed-ranks test). Four studies were excluded due to unacceptable image quality. Mean normalized rCBVs were 9.04 (SD 4.64) for the first-pass and 7.99 (SD 3.84) for the second-bolus study. There was no statistically significant difference between the two perfusion studies in either intratumoral rCBV (P=0.237) or rCBV ratio (P=0.181). Five enhancing and four non-enhancing tumors showed a relative increase in rCBV ratio on the second-bolus study, without a significant difference between the groups. Image quality was not significantly different between perfusion studies. Our results did not demonstrate a significant difference between first-pass and second-bolus rCBV measurements in DSC perfusion MR imaging. The administration of a predose of gadolinium-DTPA does not appear to be an efficient way of compensating for the underestimation of intratumoral rCBV values due to the T1 shortening effect. (orig.)

  15. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    Science.gov (United States)

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  16. Impaired bolus transit across the esophagogastric junction in postfundoplication dysphagia

    NARCIS (Netherlands)

    Scheffer, R. C. H.; Samsom, M.; Haverkamp, A.; Oors, J.; Hebbard, G. S.; Gooszen, H. G.

    2005-01-01

    This study assessed the effect of fundoplication on liquid and solid bolus transit across the esophagogastric junction (EGJ) in relation to EGJ dynamics and dysphagia. Twelve patients with gastro-esophageal reflux disease (GERD) were studied before and after fundoplication. Concurrent

  17. Electrical characterization of bolus material as phantom for use in electrical impedance and computed tomography fusion imaging

    Directory of Open Access Journals (Sweden)

    Parvind Kaur Grewal

    2014-04-01

    Full Text Available Phantoms are widely used in medical imaging to predict image quality prior to clinical imaging. This paper discusses the possible use of bolus material, as a conductivity phantom, for validation and interpretation of electrical impedance tomography (EIT images. Bolus is commonly used in radiation therapy to mimic tissue. When irradiated, it has radiological characteristics similar to tissue. With increased research interest in CT/EIT fusion imaging there is a need to find a material which has both the absorption coefficient and electrical conductivity similar to biological tissues. In the present study the electrical properties, specifically resistivity, of various commercially available bolus materials were characterized by comparing their frequency response with that of in-vivo connective adipose tissue. It was determined that the resistivity of Gelatin Bolus is similar to in-vivo tissue in the frequency range 10 kHz to 1MHz and therefore has potential to be used in EIT/CT fusion imaging studies.

  18. A prospective, randomized, blinded-endpoint, controlled study - continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia.

    Science.gov (United States)

    Nunes, Joana; Nunes, Sara; Veiga, Mariano; Cortez, Mara; Seifert, Isabel

    2016-01-01

    There is evidence that administration of a programmed intermittent epidural bolus (PIEB) compared to continuous epidural infusion (CEI) leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10mL with Ropivacaine 0.16% plus Sufentanil 10μg, parturient were randomly assigned to one of three regimens: A - Ropivacaine 0.15% plus Sufentanil 0.2μg/mL solution as continuous epidural infusion (5mL/h, beginning immediately after the initial bolus); B - Ropivacaine 0.1% plus Sufentanil 0.2μg/mL as programmed intermittent epidural bolus and C - Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10mL/h starting 60min after the initial bolus. Rescue boluses of 5mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. We analyzed 130 pregnants (A=60; B=33; C=37). The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p=0.83). We found a higher caesarean delivery rate in group A (56.7%; p=0.02). No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. A prospective, randomized, blinded-endpoint, controlled study – continuous epidural infusion versus programmed intermittent epidural bolus in labor analgesia

    Directory of Open Access Journals (Sweden)

    Joana Nunes

    2016-09-01

    Full Text Available Background: There is evidence that administration of a programmed intermittent epidural bolus (PIEB compared to continuous epidural infusion (CEI leads to greater analgesia efficacy and maternal satisfaction with decreased anesthetic interventions. Methods: In this study, 166 women with viable pregnancies were included. After an epidural loading dose of 10 mL with Ropivacaine 0.16% plus Sufentanil 10 μg, parturient were randomly assigned to one of three regimens: A – Ropivacaine 0.15% plus Sufentanil 0.2 μg/mL solution as continuous epidural infusion (5 mL/h, beginning immediately after the initial bolus; B – Ropivacaine 0.1% plus Sufentanil 0.2 μg/mL as programmed intermittent epidural bolus and C – Same solution as group A as programmed intermittent epidural bolus. PIEB regimens were programmed as 10 mL/h starting 60 min after the initial bolus. Rescue boluses of 5 mL of the same solution were administered, with the infusion pump. We evaluated maternal satisfaction using a verbal numeric scale from 0 to 10. We also evaluated adverse, maternal and neonatal outcomes. Results: We analyzed 130 pregnants (A = 60; B = 33; C = 37. The median verbal numeric scale for maternal satisfaction was 8.8 in group A; 8.6 in group B and 8.6 in group C (p = 0.83. We found a higher caesarean delivery rate in group A (56.7%; p = 0.02. No differences in motor block, instrumental delivery rate and neonatal outcomes were observed. Conclusions: Maintenance of epidural analgesia with programmed intermittent epidural bolus is associated with a reduced incidence of caesarean delivery with equally high maternal satisfaction and no adverse outcomes. Resumo: Justificativa: Há evidências de que a administração de um bolus epidural intermitente programado (BEIP comparada à infusão epidural contínua (IEC resulta em maior eficácia da analgesia e da satisfação materna, com redução das intervenções anestésicas. Métodos: Neste estudo, 166

  20. Split-bolus CT-urography using dual-energy CT: Feasibility, image quality and dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Mitsuru, E-mail: m2rbimn@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Kawai, Tatsuya; Ito, Masato; Ogawa, Masaki [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Ohashi, Kazuya [Nagoya City University Hospital, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan); Hara, Masaki; Shibamoto, Yuta [Nagoya City University Graduate School of Medical Sciences, Department of Radiology, 1 Kawasumi Mizuho-cho, Mizuho-ku, Nagoya, 467-8601 (Japan)

    2012-11-15

    Purpose: To prospectively evaluate the feasibility of dual-energy (DE) split-bolus CT-urography (CTU) and the quality of virtual non-enhanced images (VNEI) and DE combined nephrographic-excretory phase images (CNEPI), and to estimate radiation dose reduction if true non-enhanced images (TNEI) could be omitted. Patients and methods: Between August and September 2011, 30 consecutive patients with confirmed or suspected urothelial cancer or with hematuria underwent DE CT. Single-energy TNEI and DE CNEPI were obtained. VNEI was reconstructed from CNEPI. Image quality of CNEPI and VNEI was evaluated using a 5-point scale. The attenuation of urine in the bladder on TNEI and VNEI was measured. The CT dose index volume (CTDI (vol)) of the two scans was recorded. Results: The mean image quality score of CNEPI and VNEI was 4.7 and 3.3, respectively. The mean differences in urine attenuation between VNEI and TNEI were 14 {+-} 15 [SD] and -16 {+-} 29 in the anterior and posterior parts of the bladder, respectively. The mean CTDI (vol) for TNEI and CNEPI was 11.8 and 10.9 mGy, respectively. Omission of TNEI could reduce the total radiation dose by 52%. Conclusion: DE split-bolus CTU is technically feasible and can reduce radiation exposure; however, an additional TNEI scan is necessary when the VNEI quality is poor or quantitative evaluation of urine attenuation is required.

  1. Study of dose modification in skin cancers induced by the kind of bolus used - Bibliography

    International Nuclear Information System (INIS)

    Camilleri, Jeremy

    2011-01-01

    As tumour irradiation modalities differ from one pathology to another, and are even proper to each pathology (they depend on tumour nature, histology, size, location, and so on), but as therapeutic objectives remain unchanged (to deliver the prescribed dose to the target-volume with the highest possible precision while preserving as much as possible sane tissues as well as neighbouring organs at risk), this bibliographical study aims, on the one hand, at quantifying the dose variation generated by heterogeneous structures crossed by the electron beam, and on the other hand, at optimising the use of boluses during surface irradiations, notably in the case of skin cancers. The author addresses therapeutic indications of irradiation of skin cancers and of thoracic wall for which the application of a bolus is required, and then the associated irradiation techniques as well as bolus characteristics

  2. Onset and effectiveness of rocuronium for rapid onset of paralysis in patients with major burns: priming or large bolus

    Science.gov (United States)

    Han, T.-H.; Martyn, J. A. J.

    2009-01-01

    Background Burn injury leads to resistance to the effects of non-depolarizing muscle relaxants. We tested the hypothesis that a larger bolus dose is as effective as priming for rapid onset of paralysis after burns. Methods Ninety adults, aged 18–59 yr with 40 (2)% [mean (se)] burn and 30 (2) days after injury, received rocuronium as a priming dose followed by bolus (0.06+0.94 mg kg−1), or single bolus of either 1.0 or 1.5 mg kg−1. Sixty-one non-burned, receiving 1.0 mg kg−1 as a primed (0.06+0.94 mg kg−1) or full bolus dose, served as controls. Acceleromyography measured the onset times. Results Priming when compared with 1.0 mg kg−1 bolus in burned patients shortened the time to first appearance of twitch depression (30 vs 45 s, P<0.05) and time to maximum twitch inhibition (135 vs 210 s, P<0.05). The onset times between priming and higher bolus dose (1.5 mg kg−1) were not different (30 vs 30 s for first twitch depression and 135 vs 135 s for maximal depression, respectively). The onset times in controls, however, were significantly (P<0.05) faster than burns both for priming and for full bolus (15 and 15 s, respectively, for first twitch depression and 75 and 75 s for maximal depression). Priming caused respiratory distress in 10% of patients in both groups. Intubating conditions in burns were significantly better with 1.5 mg kg−1 than with priming or full 1.0 mg kg−1 bolus. Conclusions A dose of 1.5 mg kg−1 not only produces an initial onset of paralysis as early as 30 s, which we speculate could be a reasonable onset time for relief of laryngospasm, but also has an onset as fast as priming with superior intubating conditions and no respiratory side-effects. PMID:19029093

  3. Use of cornmeal bolus as an aid in obtaining cranial four-vessel angiograms.

    Science.gov (United States)

    Weathers, R M; Lee, A

    1975-01-01

    In cranial angiography it has always been difficult to visualize extracranial vessels of the cervico-thoracic region, upon one radiograph, by using the same exposure factors for both regions. For this reason, we experimented and found that by applying a dry cornmeal bolus on specific areas of the neck a technically superior radiograph of these regions can be achieved. This bolus simulated added soft tissue to the cervical region. The density of the cervical region is now similar to that of the upper thoracic. As a result, factors set for one exposure will adequately penetrate both areas.

  4. Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

    Science.gov (United States)

    Carver, Robert L; Sprunger, Conrad P; Hogstrom, Kenneth R; Popple, Richard A; Antolak, John A

    2016-05-08

    The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.

  5. Effectiveness of Bupivacaine Liposome Injectable Suspension for Postoperative Pain Control in Total Knee Arthroplasty: A Prospective, Randomized, Double Blind, Controlled Study.

    Science.gov (United States)

    DeClaire, Jeffrey H; Aiello, Paige M; Warritay, Olayinka K; Freeman, Dwight C

    2017-09-01

    We compared the effectiveness of liposomal bupivacaine to ropivacaine, each as part of multimodal pain management, in total knee arthroplasty (TKA) postoperative pain control. This prospective, double blind study randomized 96 TKA patients into a control group (periarticular injection of ropivacaine, ketorolac, morphine, and epinephrine in saline; 100cc) or an experimental group (periarticular injection of bupivacaine, ketorolac, morphine, and epinephrine in saline; 80cc plus 1.3% liposomal bupivacaine 20cc; total injection 100cc). The postoperative use of narcotics, visual analog pain scores, hours to ambulate 100 feet, and length of hospital stay were recorded. There was no significant difference between the two groups (control N = 49, experiment N = 47) in mean narcotic use per hour, total narcotic use during hospital stay, time to ambulate 100 feet, length of hospital stay, or visual analog score for pain postoperatively. There is no benefit in the use of liposomal bupivacaine compared with ropivacaine for postoperative pain control in TKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Post-mastectomy radiation therapy without usage of a bolus may be a reasonable option

    International Nuclear Information System (INIS)

    Nakamura, Naoki; Arahira, Satoko; Zenda, Sadamoto; Yoneyama, Kimiyasu; Mukai, Hirofumi; Onozawa, Masakatsu; Toshima, Masamichi; Motegi, Atsushi; Hirano, Yasuhiro; Hojo, Hidehiro; Kibe, Yuichi; Akimoto, Tetsuo

    2017-01-01

    To clarify the efficacy and toxicity of post-mastectomy radiation therapy (PMRT) without usage of a bolus, we identified 129 consecutive patients who received PMRT at the National Cancer Center Hospital East between 2003 and 2012. Seven of the 129 patients who received breast reconstruction before PMRT were excluded. All patients received PMRT of 6 MV photons, without usage of a bolus. The median follow-up duration for all eligible patients was 47.7 months (range: 4.0–123.2). Local, locoregional and isolated locoregional recurrence was found in 12 (9.8%), 14 (11%) and 5 patients (4.1%), respectively. The 3- and 5-year cumulative incidence of local recurrence, locoregional recurrence and isolated locoregional recurrence was 9.2 and 10.7%, 10.8 and 12.4%, and 4.3 and 4.3%, respectively. Although Grade 2 dermatitis was found in 11 patients (9.0%), no Grade 3–4 dermatitis was found. On univariate analysis, only a non-luminal subtype was a significant predictor for local recurrence (P < 0.001). On multivariate analysis, a non-luminal subtype remained as an independent predictor for local recurrence (P = 0.003, odds ratio: 10.9, 95% confidence interval: 2.23–53.1). In conclusion, PMRT without usage of a bolus resulted in a low rate of severe acute dermatitis without an apparent increase in local recurrence. PMRT without usage of a bolus may be reasonable, especially for patients with a luminal subtype.

  7. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Burleson, S; Baker, J; Hsia, A; Xu, Z [Stony Brook Medicine, Stony Brook, NY (United States)

    2014-06-15

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies.

  8. WE-F-16A-05: Use of 3D-Printers to Create a Tissue Equivalent 3D-Bolus for External Beam Therapy

    International Nuclear Information System (INIS)

    Burleson, S; Baker, J; Hsia, A; Xu, Z

    2014-01-01

    Purpose: The purpose of this project is to demonstrate that a non-expensive 3D-printer can be used to manufacture a 3D-bolus for external beam therapy. The printed bolus then can be modeled in our treatment planning system to ensure accurate dose delivery to the patient. Methods: We developed a simple method to manufacture a patient-specific custom 3Dbolus. The bolus is designed using Eclipse Treatment Planning System, contoured onto the patients CT images. The bolus file is exported from Eclipse to 3D-printer software, and then printed using a 3D printer. Various tests were completed to determine the properties of the printing material. Percent depth dose curves in this material were measured with electron and photon beams for comparison to other materials. In order to test the validity of the 3D printed bolus for treatment planning, a custom bolus was printed and tested on the Rando phantom using film for a dose plane comparison. We compared the dose plane measured on the film to the same dose plane exported from our treatment planning system using Film QA software. The gamma-dose distribution tool was used in our film analysis. Results: We compared point measurements throughout the dose plane and were able to achieve greater than 95% passing rate at 3% dose difference and 3 mm distance to agreement, which is our departments acceptable gamma pixel parameters. Conclusion: The printed 3D bolus has proven to be accurately modeled in our treatment planning system, it is more conformal to the patient surface and more durable than other bolus currently used (wax, superflab etc.). It is also more convenient and less costly than comparable bolus from milling machine companies

  9. Pain and Opioid Use After Total Shoulder Arthroplasty With Injectable Liposomal Bupivacaine Versus Interscalene Block.

    Science.gov (United States)

    Angerame, Marc R; Ruder, John A; Odum, Susan M; Hamid, Nady

    2017-09-01

    Postoperative pain control is a significant concern after total shoulder arthroplasty. Injectable periarticular liposomal bupivacaine, which has been found to decrease opioid use after orthopedic procedures, has been proposed as a viable alternative to regional anesthesia. This study compared the efficacy of liposomal bupivacaine vs interscalene block among patients undergoing total shoulder arthroplasty. A retrospective review was conducted of 79 patients who underwent anatomic total shoulder arthroplasty performed by a single surgeon between January 2013 and April 2015. Patient demographics, in-hospital Numeric Pain Rating Scale (NPRS) score obtained at 12-hour intervals, length of stay, and total in-hospital morphine equivalents in both the bupivacaine (n=25) and block (n=44) groups were recorded. Differences in length of stay, morphine equivalents, and age were assessed with Wilcoxon tests. Sex differences were assessed with the chi-square test. Repeated measures analysis with least square means was used to assess longitudinal changes in NPRS scores. No significant differences were found between groups for sex (P=.89), age (P=.81), American Society of Anesthesiologists classification (P=.50), preoperative opioid use (P=.41), length of stay (P=.32), or morphine equivalents (P=.71). The average NPRS score in the first 12 hours was 3.01 for the bupivacaine group and 4.41 for the interscalene block group (P=.25). By 48 hours postoperatively, average NPRS scores were similar (P=.93) for the 2 groups, 4.90 for the bupivacaine group and 4.19 for the interscalene block group. The findings for this cohort of patients undergoing anatomic total shoulder arthroplasty showed no significant difference for pain scores, postoperative narcotic use, or length of stay with injectable liposomal bupivacaine vs interscalene block. [Orthopedics. 2017; 40(5):e806-e811.]. Copyright 2017, SLACK Incorporated.

  10. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    Science.gov (United States)

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on

  11. Anxiety can significantly explain bolus perception in the context of hypotensive esophageal motility: Results of a large multicenter study in asymptomatic individuals.

    Science.gov (United States)

    Cisternas, D; Scheerens, C; Omari, T; Monrroy, H; Hani, A; Leguizamo, A; Bilder, C; Ditaranto, A; Ruiz de León, A; Pérez de la Serna, J; Valdovinos, M A; Coello, R; Abrahao, L; Remes-Troche, J; Meixueiro, A; Zavala, M A; Marin, I; Serra, J

    2017-09-01

    Previous studies have not been able to correlate manometry findings with bolus perception. The aim of this study was to evaluate correlation of different variables, including traditional manometric variables (at diagnostic and extreme thresholds), esophageal shortening, bolus transit, automated impedance manometry (AIM) metrics and mood with bolus passage perception in a large cohort of asymptomatic individuals. High resolution manometry (HRM) was performed in healthy individuals from nine centers. Perception was evaluated using a 5-point Likert scale. Anxiety was evaluated using Hospitalized Anxiety and Depression scale (HAD). Subgroup analysis was also performed classifying studies into normal, hypotensive, vigorous, and obstructive patterns. One hundred fifteen studies were analyzed (69 using HRM and 46 using high resolution impedance manometry (HRIM); 3.5% swallows in 9.6% of volunteers were perceived. There was no correlation of any of the traditional HRM variables, esophageal shortening, AIM metrics nor bolus transit with perception scores. There was no HRM variable showing difference in perception when comparing normal vs extreme values (percentile 1 or 99). Anxiety but not depression was correlated with perception. Among hypotensive pattern, anxiety was a strong predictor of variance in perception (R 2 up to .70). Bolus perception is less common than abnormal motility among healthy individuals. Neither esophageal motor function nor bolus dynamics evaluated with several techniques seems to explain differences in bolus perception. Different mechanisms seem to be relevant in different manometric patterns. Anxiety is a significant predictor of bolus perception in the context of hypotensive motility. © 2017 John Wiley & Sons Ltd.

  12. Evaluation of the esophagus with a marshmallow bolus: clarifying the cause of dysphagia.

    Science.gov (United States)

    Ott, D J; Kelley, T F; Chen, M Y; Gelfand, D W

    1991-01-01

    We reviewed the radiographic examinations of the esophagus and medical records in 117 patients (55 women and 62 men; mean age, 52 years) in which a marshmallow bolus was also given. A one-third to one-half piece of a standard marshmallow was used with a mean size of 23 mm (+/- 4.5 mm SD) measured in vivo. In 62 patients with no intrinsic structural narrowing of the esophagus, impaction occurred in only seven (11%). Four of these patients had an esophageal motility disorder, and three had a previous Nissen fundoplication. The remaining 55 patients had lower esophageal mucosal rings (47) or peptic strictures (8). Marshmallow impaction was seen in 27 of 47 rings (57%) and was inversely related to ring size, and in six of eight strictures (75%). Also, impaction was related to the ratio of bolus size to ring caliber, and invariably occurred when this ratio was greater than 1.5. Dysphagia was the presenting complaint in 76 (65%) patients, but was found equally in those without intrinsic narrowing and in those with ring or stricture. However, dysphagia was reproduced by the marshmallow bolus only in patients with esophageal narrowing or abnormal motility.

  13. Replacement of oxytocin bolus administration by infusion: influences on postpartum outcome.

    Science.gov (United States)

    Löytved-Hardegg, Julia J; Brunner, Mirjam; Ries, Jean-Jacques; von Felten, Stefanie; Heugel, Christina; Lapaire, Olav; Voekt, Cora; Hösli, Irene

    2016-06-01

    Postpartum haemorrhage (PPH) represents a leading cause of maternal morbidity and mortality. Giving oxytocin after birth reduces the risk for PPH. It has never been tested whether different methods of oxytocin administration affect the maternal outcome. This study aims to compare the infusion versus the bolus application of oxytocin after singleton vaginal delivery. This retrospective monocentre study compares the incidence of clinically relevant postpartum complications in women receiving 5 IE of oxytocin as a bolus or as a 100 ml-infusion over 5 min, given immediately after birth. Included were women delivering singletons vaginally at term. We used propensity score weighting to compare outcomes between women receiving bolus and infusion and to minimize the selection bias in this retrospective cohort. 1765 patients were included. Patient characteristics were balanced. We found no significant differences for the combined overall postpartum adverse outcome (the incidence of PPH, manual removal of the placenta and/or curettage). For the single outcomes, we observed a significantly higher frequency of manual removal of the placenta (Odds ratio 1.47, 95 % CI 1.02-2.13) and a slightly higher but clinically not relevant estimated blood loss (Relative effect 1.05, 95 % CI 1.01-1.10) in the infusion group. The data show a tendency towards more complications in the infusion group. It is related to a more frequent need for manual removal of the placenta.

  14. Bolus effect to reduce skin dose of the caontralateral breast during breast cancer radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Won, Young Jin [Dept. of Radiation Oncology, InJe University Ilsan Paik Hospital, Goyang (Korea, Republic of); Kim, Jong Won; Kim, Jung Hoon [Dept. of Radiology, Radiation Oncology, KonYang University Hospital, Daejeon (Korea, Republic of)

    2017-06-15

    The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge 15 degrees were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

  15. Continuous indomethacin infusion may be less effective than bolus infusions for ductal closure in very low birth weight infants

    NARCIS (Netherlands)

    de Vries, NKS; Jagroep, FK; Jaarsma, AS; Elzenga, NJ; Bos, AF

    The effectiveness of continuous indomethacin (INDO) infusion versus bolus infusions for closure of patent ductus arteriosus (PDA) was investigated. The study design was an open-label case series (continuous INDO) with historic controls matched for gestational age (bolus INDO). Ductal closure rates

  16. Implementation of a split-bolus single-pass CT protocol at a UK major trauma centre to reduce excess radiation dose in trauma pan-CT

    International Nuclear Information System (INIS)

    Leung, V.; Sastry, A.; Woo, T.D.; Jones, H.R.

    2015-01-01

    Aim: To quantify the dose reduction and ensure that the use of a split-bolus protocol provided sufficient vascular enhancement. Materials and methods: Between 1 January 2014 and 31 May 2014, both split bolus and traditional two-phase scans were performed on a single CT scanner (SOMATOM Definition AS+, Siemens Healthcare) using a two-pump injector (Medrad Stellant). Both protocols used Siemens' proprietary tube current and tube voltage modulation techniques (CARE dose and CARE kV). The protocols were compared retrospectively to assess the dose–length product (DLP), aortic radiodensity at the level of the coeliac axis and radiodensity of the portal vein. Results: There were 151 trauma CT examinations during this period. Seventy-eight used the split-bolus protocol. Seventy-one had traditional two-phase imaging. One patient was excluded as they were under the age of 18 years. The radiodensity measurements for the portal vein were significantly higher (p<0.001) in the split-bolus protocol. The mean aortic enhancement in both protocols exceeded 250 HU, although the traditional two-phase protocol gave greater arterial enhancement (p<0.001) than the split-bolus protocol. The split-bolus protocol had a significantly lower (p<0.001) DLP with 43.5% reduction in the mean DLP compared to the traditional protocol. Conclusion: Split-bolus CT imaging offers significant dose reduction for this relatively young population while retaining both arterial and venous enhancement. -- Highlights: •We implemented a split bolus pan-CT protocol for trauma CT. •We compared the radiation dose and vascular enhancement of the split bolus protocol to a traditional two phase protocol. •The split bolus protocol had a 43.5% reduction in mean DLP

  17. Comparison of Bolus Phenylephrine, Ephedrine and Mephentermine for Maintenance of Arterial Pressure during Spinal Anesth

    Directory of Open Access Journals (Sweden)

    B Bhattarai

    2010-03-01

    Full Text Available INTRODUCTION: Hypotension is common following spinal anesthesia. Various vasopressors have been indicated to prevent it. The study compares three such agents namely phenylephrine, ephedrine and mephentermine. METHODS: The study included 90 patients undergoing elective and emergency cesarean section who developed hypotension following subarachnoid blockade. Parturient were randomly divided into three groups each group had 30 patients. Group P received bolus of Phenylephrine 25 microgram, where as group E received Ephedrine 5mg and Group M received Mephentermine 6mg. RESULTS: It was found that rise of blood pressure was significantly higher in case of phenylephrine group in first six minutes, after the bolus, there was significant reduction in the heart rate in phenylephrine group, but there was tachycardia following administration of bolus ephedrine and mephenteramine. Neonatal APGAR score were similar in all three groups. CONCLUSIONS: All three drugs maintained hemodynamics within 20 percent of the baseline values on intravenous administration. Keywords: APGAR, ephedrine, hypotension, mephentermine, phenylephrine, spinal anesthesia.

  18. Rapid Bolus Administration Does not Increase The Extravasation Rate of Albumin: A Randomized Controlled Trial in The Endotoxemic Pig.

    Science.gov (United States)

    von Seth, Magnus; Lipcsey, Miklós; Engström, Peter; Larsson, Anders; Hillered, Lars; Maripuu, Enn; Widström, Charles; Sjölin, Jan

    2017-04-01

    Some experimental data suggest that rapid bolus administration of albumin causes less plasma-expanding effects than slow, continuous infusion. To determine whether rapid bolus administration, in comparison with slow infusion, results in greater extravasation of albumin in experimental septic shock we performed a randomized controlled trial with 32 endotoxemic pigs. The animals were monitored and ventilated with standard intensive care equipment and given 10 mL × kg 5% albumin labeled with Technetium-99m, either as a rapid 15-min bolus (Bolus group, n = 16) or as a 2-h infusion (Infusion group, n = 16). Radioactivity was monitored in plasma, extracellular microdialysate, and urine for 6 h. Physiological parameters were monitored hourly. Radioactivity in the liver, spleen, kidney, and lung was analyzed post mortem.The plasma area under the curve activity0-6 h was 4.4 ± 0.9 × 10 in the Bolus group and 4.4 ± 1.1 × 10 counts × min × mL × h in the Infusion group. Blood hemoglobin levels increased in both groups, suggesting severe capillary leakage. Yet, there were no group differences in albumin radioactivity in plasma, muscle tissue, urine, or in the post-mortem analysis of the organs. Following albumin administration, circulatory and respiratory parameters were similar in the two groups.In conclusion, the present results suggest that albumin might be given as a bolus without leading to increased extravasation of albumin, in contrast to previous animal experiments in rodents.

  19. Should colloid boluses be prioritized over crystalloid boluses for the management of dengue shock syndrome in the presence of ascites and pleural effusions?

    Directory of Open Access Journals (Sweden)

    Weerasinghe Mindu

    2011-02-01

    Full Text Available Abstract Background Although the WHO guideline for the management of dengue fever considers the presence of ascites or pleural effusions in the diagnosis of DSS, it does not emphasize the importance of their presence when selecting fluids for resuscitation. Case presentation We highlight three patients with DSS who received boluses of crystalloids on priority basis as recommended by WHO guidelines during resuscitation. All three patients had varying degrees of third space fluid loss (ascites and pleural effusions at the time of development of DSS. Ascites and pleural effusions were detected in all 3 patients at the time of shock irrespective of whether iv fluids were given or not. All three patients had documented liver involvement at the time of shock evidenced by elevation of AST (4800 iu/L, 5000 iu/L and 1960 iu/L. One patient who had profound shock died 6 hours after admission with evidence of acute pulmonary oedema in the convalescence phase. All of them needed CPAP ventilator support and potent diuretics. Conclusions We therefore feel that resuscitation of patients with DSS who already have third space fluid accumulation with crystalloid boluses on priority basis may contribute to recovery phase pulmonary oedema.

  20. 21 CFR 520.1720a - Phenylbutazone tablets and boluses.

    Science.gov (United States)

    2010-04-01

    ... Section 520.1720a Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...-mg or 1-g tablets, or 2- or 4-g boluses, in dogs and horses. (2) Nos. 000010 and 059130 for use of 100- or 200-mg or 1-g tablets in dogs and horses. (3) Nos. 000856 and 061623 for use of 100-mg or 1-g...

  1. Continuous transversus abdominis plane block vs intermittent bolus for analgesia after abdominal surgery: a randomized trial

    Directory of Open Access Journals (Sweden)

    Rao Kadam V

    2017-07-01

    Full Text Available Vasanth Rao Kadam,1 Roelof M Van Wijk,1 John L Moran,2 Shantan Ganesh,3 A Kumar,1 Rajesh Sethi,1 Patricia Williams2,4 1Department of Anaesthesia, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 2Intensive Care Unit, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 3Department of Surgery, The Queen Elizabeth Hospital, School of Medicine, University of Adelaide, Adelaide, SA, 4Department of Epidemiology and Preventive Medicine, School Public Health and Preventive Medicine, Australian and New Zealand Intensive Care Research Centre, Monash University, Melbourne, VIC, Australia Background: Continuous and intermittent bolus techniques of transversus abdominis plane (TAP blocks have been used for analgesia after abdominal surgery. Although both are effective, there are no studies comparing them. The aim of this study is to compare analgesia and cost-effectiveness between these groups.Methods: After obtaining ethical approval, 20 American Society of Anesthesiologists ASA grade I to III patients undergoing elective abdominal surgery were recruited with 10 patients allocated to each arm. Bilateral ultrasound-guided TAP blocks were performed with an initial bolus of 0.5% ropivacaine 20 mL per side, followed by catheter insertion. After surgery, the continuous infusion group received 0.2% ropivacaine 8 mL/hour on each side and the intermittent bolus group received doses of 0.2% ropivacaine 20 mL per side every 8 hours for 48 hours. Both groups received intravenous fentanyl patient-controlled analgesia and regular oral paracetamol. Parameters recorded included numerical rating scores for pain and post-operative analgesic consumption at baseline (time 0 and at 1 hour, 1 day and 2 days post-operatively. The duration of catheter insertion, complications, patient satisfaction and information regarding costs were also recorded. Patient satisfaction was assessed utilizing a 4-point

  2. Intra-articular injection of tranexamic acid via a drain plus drain-clamping to reduce blood loss in cementless total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Mutsuzaki Hirotaka

    2012-09-01

    Full Text Available Abstract Background Patients undergoing cementless total knee arthroplasty (TKA sometimes suffer large blood loss. In a retrospective study, we explored whether postoperative intra-articular retrograde injection of tranexamic acid (TA and leaving a drain clamp in place for 1 h reduced blood loss. Patients and methods Patients (n = 140 treated with unilateral primary cementless TKA (posterior cruciate ligament retained were divided into two groups: those who had an intra-articular injection of TA (1000 mg and drain clamping for 1 h postoperatively (study group, n = 70 and those who were not given TA and did not undergo clamping of their drains (control group, n = 70. Postoperative total blood loss, volume of drainage, hemoglobin level, transfusion amounts and rates, D-dimer level at postoperative day (POD 7, and complications were recorded. Results Total blood loss, total drainage, mean transfusion volume, and transfusion rates were lower in the study group than in controls (P P P  Conclusions Immediately postoperative intra-articular retrograde injection of TA and 1 h of drain-clamping effectively reduced blood loss and blood transfusion after cementless TKA. We believe that this method is simple, easy, and suitable for these patients.

  3. INFLUENCE OF AGE ON SWALLOWS OF A HIGHLY VISCOUS LIQUID BOLUS

    Directory of Open Access Journals (Sweden)

    Weslania Viviane NASCIMENTO

    2015-03-01

    Full Text Available Background Swallow function has a decline with aging, mainly in those over 80 years old. In the population over 69 years, about 11% of subjects reported symptoms indicative of significant dysphagia. Objectives Our objective was to evaluate the hypothesis that older asymptomatic subjects before 80 years old have compensations to sustain a safe and efficient swallow, at least with swallows of liquid bolus. Methods We performed videofluoroscopic evaluation of swallows in 55 normal volunteers, a younger group with 33 subjects (16 men and 17 women aged 19 to 55 years, mean 35.5±9.8 years, and an older group with 22 subjects (15 men and 7 women aged 56 to 77 years, mean 64.8±6.8 years. The subjects swallowed in duplicate 5 mL and 10 mL of liquid barium with a pH of 7.9, density of 1.82 g/cm3, and viscosity of 895 cp. Results The mean duration of pharyngeal transit, pharyngeal clearance, upper esophageal sphincter opening, hyoid movement and oral-pharyngeal transit were longer in the younger group compared with the older group. The relation between pharyngeal clearance duration and hyoid movement duration was similar in younger and older subjects, for 5 mL and 10 mL bolus volumes. Conclusions On average, a highly viscous liquid bolus crosses the pharynx faster in older subjects (56-77 years old than in younger subjects (19-55 years old, which suggested an adaptation to the aging process to maintain a safe swallow.

  4. The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes

    Science.gov (United States)

    Abdollahi, E.; Kohram, H.; Shahir, M. H.; Nemati, M. H.

    2015-01-01

    Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a single Ferrobloc bolus four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 2 received two boluses four weeks prior to CIDR insertion following 400 IU eCG on CIDR removal, group 3 received only 400 IU eCG on CIDR removal and group 4 (control) received no bolus and no eCG. Transrectal ultrasonography was done to monitor the ovarian follicles on the day of CIDR removal and a day later. Results showed that boluses increased the status of copper, selenium and iodine on mating day and days 90 to 100 of gestation. Ruminal bolus did not significantly increase the number of different classes of ovarian follicles in ewes fed a diet meeting all trace mineral requirements. All ewes eventually became pregnant with 1 or 2 boluses but the multiple births rate (80%) was higher (P<0.05) after 2 boluses compared to the other groups. PMID:27175153

  5. Bolus fluid therapy and sodium homeostasis in paediatric gastroenteritis.

    Science.gov (United States)

    Freedman, Stephen B; Geary, Denis F

    2013-03-01

    The study aims to assess the risk of developing hyponatraemia when large-volume bolus fluid rehydration therapy is administered. We conducted a prospective randomised study in a tertiary-care centre emergency department. Participants included children with gastroenteritis and dehydration requiring intravenous rehydration. They were randomised to receive 60 mL/kg (large) or 20 mL/kg (standard) 0.9% saline bolus followed by maintenance 0.9% saline for 3 h. Biochemical tests were performed at baseline and 4 h. The primary outcome measure was the development of hyponatraemia at 4 h. Secondary outcome measures were (i) change in sodium relative to baseline value; (ii) magnitude of decrease among those who experienced a decrease; (iii) risk of hypernatraemia; (iv) correlations between urine parameters and hyponatraemia; and (v) fluid overload. Eighty-four of 224 (38%) participants were hyponatraemic at baseline. At 4 h, 22% (48/217) had a dysnatraemia, and similar numbers of children were hyponatraemic in both groups: large (23% (26/112)) versus standard (21% (22/105)) (P = 0.69). Among initially hyponatraemic children, 63% (30/48) who received large-volume rehydration and 44% (15/34) of those administered standard rehydration were isonatraemic at 4 h (P = 0.10). Overall, children who received 60 mL/kg experienced a larger mean increase (1.6 ± 2.4 mEq/L vs. 0.9 ± 2.2 mEq/L; P = 0.04) and were less likely to experience a sodium decrease of ≥2 mEq/L (8/112 vs. 17/105; P = 0.04) than those administered 20 mL/kg. Large-volume bolus rehydration therapy with 0.9% saline is safe. It does not promote the development of hyponatraemia over the short term, but hastens the resolution of baseline hyponatraemia. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  6. Retention of 99mTc-bicisate in the human brain after intracarotid injection

    DEFF Research Database (Denmark)

    Friberg, L; Andersen, A R; Lassen, N A

    1994-01-01

    99mTc-bicisate (ECD) was injected as a bolus into the internal carotid artery, and cerebral uptake and retention were recorded with fast-rotating single photon emission computed tomography (SPECT) equipment in four patients suffering from temporal lobe epilepsy. Quantitative regional cerebral blood...... flow (rCBF) was measured tomographically with the 133Xe inhalation technique. We applied a three-compartment kinetic model and algorithms modified from a previous analysis of 99mTc d,l-hexamethylpropyleneamine oxide (HM-PAO) kinetics. The bicisate brain uptake and retention curve was very similar...

  7. Comparison between intravenous boluses versus infusion of tranexamic acid (TXA) to reduce bleeding in paediatric cyanotic congenital heart disease (CHD) surgeries

    International Nuclear Information System (INIS)

    Junejo, F.; Irfan, M.; Akhtar, M.I.; Hamid, M.; Ahmed, S.S.

    2018-01-01

    To compare the intravenous boluses and intravenous continuous infusion of tranexamic acid (TXA) to reduce postoperative bleeding in cyanotic congenital heart disease surgeries. Study Design:Single-blinded randomised clinical trial. Place and Duration of Study:Anaesthesia Department, The Aga Khan University Hospital, Karachi, from July 2016 to April 2017. Methodology:Sixty patients of cyanotic congenital heart disease, undergoing either palliative or corrective surgery involving cardiopulmonary bypass (CPB), were recruited. These 60 patients were divided randomly into two groups. The infusion group received intravenous infusion of TXA at 5 mg/kg/hour while the bolus group received three intravenous boluses of 10 mg/kg after induction, after going to bypass and after protamine reversal. Data was collected through predesigned proforma. There were two primary outcomes: postoperative bleeding in the first 24 hours, and chest closure time. Results:Postoperative bleeding was 13.94 (10.27-20.18) ml/kg in the first 24 hours in infusion group and 15.05 (9.04-23.50) ml/kg in the bolus group. Chest closure time was 38.5 (25-45) in infusion group and 30 (20-46.25) minutes in the bolus group. There was no statistically significant and clinical difference between both groups regarding postoperative bleeding in the first 24 hours and chest closure time. Conclusion:These infusion and bolus groups had comparable postoperative bleeding and chest closure time. (author)

  8. Pharmacokinetics of rocuronium after bolus and continuous infusion during halothane anaesthesia

    NARCIS (Netherlands)

    McCoy, E.P; Mirakhur, R.K; Maddineni, V.R; Wierda, J.MKH; Proost, Hans

    We have studied the pharmacokinetics of a single bolus of rocuronium (Org 9426), followed by an infusion, in eight patients during anaesthesia with halothane and nitrous oxide in oxygen. Neuromuscular block was monitored using train-of-four (TOF) stimulation and recording the force of contraction of

  9. The Effect of Bolus Volume on Hyoid Kinematics in Healthy Swallowing

    Directory of Open Access Journals (Sweden)

    Ahmed Nagy

    2014-01-01

    Full Text Available Hyoid movement in swallowing is biomechanically linked to closure of the laryngeal vestibule for airway protection and to opening of the upper esophageal sphincter. Studies suggest that the range of hyoid movement is highly variable in the healthy population. However, other aspects of hyoid movement such as velocity remain relatively unexplored. In this study, we analyze data from a sample of 20 healthy young participants (10 male to determine whether hyoid movement distance, duration, velocity, and peak velocity vary systematically with increases in thin liquid bolus volume from 5 to 20 mL. The temporal correspondence between peak hyoid velocity and laryngeal vestibule closure was also examined. The results show that maximum hyoid position and peak velocity increase significantly for 20 mL bolus volumes compared to smaller volumes, and that the timing of peak velocity is closely linked to achieving laryngeal vestibule closure. This suggests that generating hyoid movements with increased power is a strategy for handling larger volumes.

  10. A mathematical model for the movement of food bolus of varying viscosities through the esophagus

    Science.gov (United States)

    Tripathi, Dharmendra

    2011-09-01

    This mathematical model is designed to study the influence of viscosity on swallowing of food bolus through the esophagus. Food bolus is considered as viscous fluid with variable viscosity. Geometry of esophagus is assumed as finite length channel and flow is induced by peristaltic wave along the length of channel walls. The expressions for axial velocity, transverse velocity, pressure gradient, volume flow rate and stream function are obtained under the assumptions of long wavelength and low Reynolds number. The impacts of viscosity parameter on pressure distribution, local wall shear stress, mechanical efficiency and trapping are numerically discussed with the help of computational results. On the basis of presented study, it is revealed that swallowing of low viscous fluids through esophagus requires less effort in comparison to fluids of higher viscosity. This result is similar to the experimental result obtained by Raut et al. [1], Dodds [2] and Ren et al. [3]. It is further concluded that the pumping efficiency increases while size of trapped bolus reduces when viscosity of fluid is high.

  11. A Phase 1, Single-center, Double-blind, Placebo-controlled Study in Healthy Subjects to Assess the Safety, Tolerability, Clinical Effects, and Pharmacokinetics-Pharmacodynamics of Intravenous Cyclopropyl-methoxycarbonylmetomidate (ABP-700) after a Single Ascending Bolus Dose.

    Science.gov (United States)

    Struys, Michel M R F; Valk, Beatrijs I; Eleveld, Douglas J; Absalom, Anthony R; Meyer, Peter; Meier, Sascha; den Daas, Izaak; Chou, Thomas; van Amsterdam, Kai; Campagna, Jason A; Sweeney, Steven P

    2017-07-01

    Cyclopropyl-methoxycarbonylmetomidate (ABP-700) is a new "soft" etomidate analog. The primary objectives of this first-in-human study were to describe the safety and efficacy of ABP-700 and to determine its maximum tolerated dose. Secondary objectives were to characterize the pharmacokinetics of ABP-700 and its primary metabolite (cyclopropyl-methoxycarbonyl acid), to assess the clinical effects of ABP-700, and to investigate the dose-response and pharmacokinetic/pharmacodynamic relationships. Sixty subjects were divided into 10 cohorts and received an increasing, single bolus of either ABP-700 or placebo. Safety was assessed by clinical laboratory evaluations, infusion-site reactions, continuous monitoring of vital signs, physical examination, adverse event monitoring, and adrenocorticotropic hormone stimulation testing. Clinical effects were assessed with modified observer's assessment of alertness/sedation and Bispectral Index monitoring. Pharmacokinetic parameters were calculated. Stopping criteria were met at 1.00 mg/kg dose. No serious adverse events were reported. Adverse events were dose-dependent and comprised involuntary muscle movement, tachycardia, and ventilatory effects. Adrenocorticotropic hormone stimulation evoked a physiologic cortisol response in all subjects, no different from placebo. Pharmacokinetics were dose-proportional. A three-compartment pharmacokinetic model described the data well. A rapid onset of anesthesia/sedation after bolus administration and also a rapid recovery were observed. A quantitative concentration-effect relationship was described for the modified observer's assessment of alertness/sedation and Bispectral Index. This first-in-human study of ABP-700 shows that ABP-700 was safe and well tolerated after single-bolus injections up to 1.00 mg/kg. Bolus doses of 0.25 and 0.35 mg/kg were found to provide the most beneficial clinical effect versus side-effect profile.

  12. Differential Response Pattern of Oropharyngeal Pressure by Bolus and Dry Swallows.

    Science.gov (United States)

    Hasegawa, Mana; Kurose, Masayuki; Okamoto, Keiichiro; Yamada, Yoshiaki; Tsujimura, Takanori; Inoue, Makoto; Sato, Taisuke; Narumi, Takatsune; Fujii, Noritaka; Yamamura, Kensuke

    2018-02-01

    The aim of this study was to determine if bolus and dry swallow showed similar pressure changes in the oropharynx using our newly developed device. A unique character of it includes that baropressure can be measured with the sensor being placed in the balloon and can assess the swallowing mechanics in terms of pressure changes in the oropharynx with less influences of direct contacts of boluses and oropharyngeal structures during swallow indirectly. Fifteen healthy subjects swallowed saliva (dry), 15 ml of water, 45 ml of water, and 15 ml of two different types of food in terms of viscosity (potage soup-type and mayonnaise-type foods). Suprahyoid muscle activity was recorded simultaneously. Three parameters, area under the curve (AUC), peak amplitude, and duration of pressure, were analyzed from each swallow. Almost all of the bolus swallowing events had biphasic baropressure responses consisting of an early phase and late phase (99%), whereas 90% of the saliva swallowing events had a single phase. AUC, peak, and duration displayed greater effects during the late phase than during the early phase. Baropressure of the early phase, but not of the late phase, significantly increased with increasing volume; however, small but significant viscosity effects on pressure were seen during both phases. Peak pressure of the late phase was preceded by maximum muscle activity, whereas that of the early phase was seen when muscle activity displayed a peak response. These findings indicated that our device with the ability to measure baropressure has the potential to provide additional parameter to assess the swallow physiology, and biphasic baropressure responses in the early and late phases could reflect functional aspects of the swallowing reflexes.

  13. Fractional filling with the microdepot technique as an alternative to bolus hyaluronic acid injections in facial volume restoration.

    Science.gov (United States)

    Lim, Adrian C; Lowe, Patricia M

    2011-05-01

    For volume restoration of the face, hyaluronic acid is conventionally injected through long, large-bore, 18-gauge needles because of the higher viscosity subtypes required. These hyaluronic acids are either more highly cross-linked or larger in particle size than the less-viscous subtypes. The microdepot injection technique involves using the 31-gauge BD insulin syringe (Becton-Dickinson, North Ryde, NSW Australia) to deposit small amounts of filler (0.05-0.1 mL) throughout the area of volume loss. The procedure is extremely well tolerated, requiring only topical and ice anaesthesia. Using this method, volume restoration can be achieved naturally and progressively over a period of time. Fractional filling every 3-4 months is continued until the desired level of volume correction is attained. Patients undergoing fractional filling followed over a 12-month period did not indicate any observable compromise in filler longevity, even when highly viscous hyaluronic acid fillers were injected through small-bore, 31-gauge insulin syringes. © 2011 The Authors. Australasian Journal of Dermatology © 2011 The Australasian College of Dermatologists.

  14. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd [CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba, CancerCare Manitoba (Canada)

    2016-08-15

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  15. Poster - 38: On the physical and dosimetric properties of 3D printed electron bolus fabricated using polylactic acid

    International Nuclear Information System (INIS)

    Sasaki, David; Jensen, Martin; Rickey, Daniel W; Dubey, Arbind; Harris, Chad; McCurdy, Boyd

    2016-01-01

    Purpose: 3D printing technology could simplify and improve electron bolus fabrication. The purpose of this study was to characterize the density, dimensional accuracy, uniformity, and attenuation of PLA boluses fabricated with a low-cost 3D printer. Methods: Several solid square slabs were printed with specific requested dimensions and 100% infill using different fill patterns. These pieces were imaged using an x-ray flat panel imager in order to check for uniformity of the prints. Percentage depth doses (PDDs) were measured downstream of the slabs in solid water using a parallel plate chamber and compared to measurements in water in order to characterize attenuation. The dimensions of the PLA slabs were measured using digital calipers. The slabs were also weighed to find their density. Results: The fill pattern used to create boluses can affect the attenuation of the bolus. Fill patterns should be chosen carefully and quality assurance should be done for each printed piece. PLA causes the electron PDD to shift towards shallower depths, compared to water, by 1.7 mm for each centimeter of PLA. Agreement with design dimensions was within 1 mm in the plane of the printer bed, and within 1/3 of a millimeter (roughly the thickness of a single layer), perpendicular to the printer bed. Average density was in the range 1.20 – 1.22. Conclusions: 3D printing shows great promise for use in fabricating electron bolus. This work indicates that printed PLA can be a suitable material provided the increased attenuation is properly accounted for.

  16. A feasibility study of a 3-day basal-bolus insulin delivery device in individuals with type 2 diabetes.

    Science.gov (United States)

    Mader, Julia K; Lilly, Leslie C; Aberer, Felix; Korsatko, Stefan; Strock, Ellie; Mazze, Roger S; Damsbo, Peter; Pieber, Thomas R

    2014-05-01

    This study tested the feasibility of transition from multiple daily injections (MDI) to a 3-day, basal-bolus insulin delivery device (PaQ) for type 2 diabetes (T2D). Twenty MDI-treated individuals with T2D with HbA(1c) ≤9% (75 mmol/mol) were enrolled in a single-center, single-arm pilot study, lasting three 2-week periods: baseline (MDI), transition to PaQ, and PaQ therapy. Feasibility of use, glycemic control, safety, and patient satisfaction were assessed. Nineteen participants transitioned to PaQ treatment and demonstrated competency in assembling, placing, and using the device. Self-monitored blood glucose and blinded continuous glucose-monitoring data showed glycemic control similar to MDI. Study participants reported high satisfaction and device acceptance. PaQ treatment is both feasible and acceptable in individuals with T2D. Transition from MDI is easy and safe. PaQ treatment might lead to better therapy adherence and improvements in glycemic control and clinical outcomes.

  17. The reliability and validity of passive leg raise and fluid bolus to assess fluid responsiveness in spontaneously breathing emergency department patients

    DEFF Research Database (Denmark)

    Duus, Nicolaj; Shogilev, Daniel J; Skibsted, Simon

    2015-01-01

    PURPOSE: We investigated the reproducibility of passive leg raise (PLR) and fluid bolus (BOLUS) using the Non-Invasive Cardiac Output Monitor (NICOM; Cheetah Medical, Tel Aviv, Israel) for assessment of fluid responsiveness (FR) in spontaneously breathing emergency department (ED) patients. METHODS...

  18. A 125I-radiolabelled probe for vinblastine and vindesine radioimmunoassays: applications to measurements of vindesine plasma levels in man after intravenous injections and long-term infusions

    International Nuclear Information System (INIS)

    Rahmani, R.; Barbet, J.; Cano, J.-P.

    1983-01-01

    The transformation of vinblastine into a reactive acid azide was used for the preparation of a vindesine-glycyl-tyrosine conjugate. This conjugate was radiolabelled [ 125 I] and used as a tracer for the radioimmunoassay of vinblastine and vindesine with antisera developed by the Eli Lilly Research Laboratories and by the authors. Its higher specific activity as compared to tritiated vinblastine significantly increases the sensitivity of the assay (0.05 μg/l as compared to 0.6 μg/l). It was then possible to monitor vindesine plasma levels for more than 60 h after intravenous bolus injection and to evaluate the elimination rates more accurately. When plasma levels were also measurable using tritiated vinblastine a satisfactory agreement was observed with determinations performed with radioiodinated vindesine-glycyl-tyrosine. Furthermore, the use of a #betta#-emitting probe simplifies the radioimmunoassay procedure and accordingly increases its reproducibility. A few examples of vindesine level measurements in human plasma collected after bolus intravenous injection and during long-term infusion are given. (Auth.)

  19. Comparison of bolus versus fractionated oral applications of [13C]-linoleic acid in humans.

    Science.gov (United States)

    Demmelmair, H; Iser, B; Rauh-Pfeiffer, A; Koletzko, B

    1999-07-01

    The endogenous conversion of linoleic acid into long-chain polyunsaturated fatty acids is of potential importance for meeting substrate requirements, particularly in young infants. After application of [13C]-linoleic acid, we estimated its conversion to dihomo-gamma-linolenic and arachidonic acids from only two blood samples. Oral tracer doses were given to five healthy adults as a single bolus. In four subjects the tracer was given in nine equal portions over 3 days. Concentration and 13C content of fatty acids from serum phospholipids were analysed by gas chromatography combustion isotope ratio-mass spectrometry. Areas under the tracer-concentration curves were calculated, and fractional transfer and turnover rates estimated from compartmental models. The median fractional turnover of linoleic acid was 93.7% per day (interquartile range 25.3) in the bolus group and 80. 0% per day (6.3) in the fraction group (NS). Fractional conversion of linoleic to dihomo-gamma-linolenic acid was 1.5% (0.9) vs. 2.1% (0.7) (bolus vs. fraction, P /= 0.94, P < 0.05) with the ratio of areas under the curve. Using areas under the curve overestimates the conversion, because different residence times are not considered. Estimation of conversion intensity appears possible with only one blood sample obtained after tracer application.

  20. The safety of peri-articular local anaesthetic injection for patients undergoing total knee replacement with autologous blood transfusion: a randomised trial.

    Science.gov (United States)

    Wallace, D F; Emmett, S R; Kang, K K; Chahal, G S; Hiskens, R; Balasubramanian, S; McGuinness, K; Parsons, H; Achten, J; Costa, M L

    2012-12-01

    Intra-operative, peri-articular injection of local anaesthesia is an increasingly popular way of controlling pain following total knee replacement. At the same time, the problems associated with allogenic blood transfusion have led to interest in alternative methods for managing blood loss after total knee replacement, including the use of auto-transfusion of fluid from the patient's surgical drain. It is safe to combine peri-articular infiltration with auto-transfusion from the drain. We performed a randomised clinical trial to compare the concentration of local anaesthetic in the blood and in the fluid collected in the knee drain in patients having either a peri-articular injection or a femoral nerve block. Clinically relevant concentrations of local anaesthetic were found in the fluid from the drains of patients having peri-articular injections (4.92 μg/ml (sd 3.151)). However, none of the patients having femoral nerve blockade had detectable levels. None of the patients in either group had clinically relevant concentrations of local anaesthetic in their blood after re-transfusion. The evidence from this study suggests that it is safe to use peri-articular injection in combination with auto-transfusion of blood from peri-articular drains during knee replacement surgery.

  1. Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.

    Science.gov (United States)

    Rosales, Nicolás; De Battista, Hernán; Vehí, Josep; Garelli, Fabricio

    2018-06-01

    Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus insulin infusion). This paper presents a method for automatic insulin bolus shaping based on insulin-on-board (IOB) as an alternative to conventional bolus dosing. The methodology presented allows the pump to generate the so-called super-bolus (SB) employing a two-compartment IOB dynamic model. The extra amount of insulin to boost the bolus and the basal cutoff time are computed using the duration of insulin action (DIA). In this way, the pump automatically re-establishes basal insulin when IOB reaches its basal level. Thus, detrimental transients caused by manual or a-priori computations are avoided. The potential of this method is illustrated via in-silico trials over a 30 patients cohort in single meal and single day scenarios. In the first ones, improvements were found (standard treatment vs. automatic SB) both in percentage time in euglycemia (75g meal: 81.9 ± 15.59 vs. 89.51 ± 11.95, ρ ≃ 0; 100g meal: 75.12 ± 18.23 vs. 85.46 ± 14.96, ρ ≃ 0) and time in hypoglecymia (75g meal: 5.92 ± 14.48 vs. 0.97 ± 4.15, ρ=0.008; 100g meal: 9.5 ± 17.02 vs. 1.85 ± 7.05, ρ=0.014). In a single day scenario, considering intra-patient variability, the time in hypoglycemia was reduced (9.57 ± 14.48 vs. 4.21 ± 6.18, ρ=0.028) and improved the time in euglycemia (79.46 ± 17.46 vs. 86.29 ± 11.73, ρ=0.007). The automatic IOB-based SB has the potential of a better performance in comparison with the standard treatment, particularly for high glycemic index meals with high carbohydrate content. Both glucose excursion and time spent in hypoglycemia were reduced. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. The retention of [99mTc]-d,l-HM-PAO in the human brain after intracarotid bolus injection

    DEFF Research Database (Denmark)

    Lassen, N A; Andersen, A R; Friberg, L

    1988-01-01

    [99mTc]-d,l-HM-PAO (HM-PAO) was injected rapidly into the internal carotid artery and its retention in the brain was recorded by external scintillation cameras in eight human subjects. A model is described based on three compartments: the lipophilic tracer in the blood pool of the brain, the lipo......[99mTc]-d,l-HM-PAO (HM-PAO) was injected rapidly into the internal carotid artery and its retention in the brain was recorded by external scintillation cameras in eight human subjects. A model is described based on three compartments: the lipophilic tracer in the blood pool of the brain...

  3. Closed-loop double-vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial.

    Science.gov (United States)

    Sng, B L; Tan, H S; Sia, A T H

    2014-01-01

    Hypotension necessitating vasopressor administration occurs commonly during caesarean section under spinal anaesthesia. We developed a novel vasopressor delivery system that automatically administers phenylephrine or ephedrine based on continuous non-invasive arterial pressure monitoring. A phenylephrine bolus of 50 μg was given at 30-s intervals when systolic blood pressure fell manual boluses of either phenylephrine 100 μg or ephedrine 8 mg, administered at 1-min intervals based on the same thresholds for systolic pressure and heart rate. This randomised, controlled, double-blinded trial involved 213 healthy women who underwent elective caesarean delivery under spinal anaesthesia using 11 mg hyperbaric bupivacaine with 15 μg fentanyl and 100 μg morphine. The automated vasopressor group had better systolic pressure control, with 37/106 (34.9%) having any beat-to-beat systolic pressure reading 120% of baseline, with 8/106 (7.5%) in the automated vasopressor group vs 14/107 (13.1%) in the control group, or total dose of vasopressors. The automated vasopressor group had lower median absolute performance error of 8.5% vs control of 9.8% (p = 0.013), and reduced incidence of nausea (1/106 (0.9%) vs 11/107 (10.3%), p = 0.005). Neonatal umbilical cord pH, umbilical lactate and Apgar scores were similar. Hence, our system afforded better control of maternal blood pressure and reduced nausea with no increase in reactive hypertension when compared with manual boluses. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  4. Cerebral hemodynamic changes measured by gradient-echo or spin-echo bolus tracking and its correlation to changes in ICA blood flow measured by phase-mapping MRI

    DEFF Research Database (Denmark)

    Marstrand, J.R.; Rostrup, Egill; Garde, Ellen

    2001-01-01

    Changes in cerebral blood flow (CBF) induced by Acetazolamide (ACZ) were measured using dynamic susceptibility contrast MRI (DSC-MRI) with both spin echo (SE) EPI and gradient echo (GE) EPI, and related to changes in internal carotid artery (ICA) flow measured by phase-mapping. Also examined...... increase in CBF and CBV in response to ACZ, while SE-EPI measured a significant increase in CBV and MTT. CBV and MTT change measured by SE-EPI was sensitive to previous bolus injections. There was a significant linear relation between change in CBF measured by GE-EPI and change in ICA flow. In conclusion......, GE-EPI under the present condition was superior to SE-EPI in monitoring cerebral vascular changes...

  5. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  6. Dextrose boluses versus burette dextrose infusions in prevention of hypoglycemia among preterms admitted at Mulago Hospital: an open label randomized clinical trial.

    Science.gov (United States)

    Kutamba, E; Lubega, S; Mugalu, J; Ouma, J; Mupere, E

    2014-09-01

    Hypoglycemia is a major cause of morbidity and mortality among preterm infants and its management remains a challenge in resource limited settings. Use of dextrose infusion by the recommended infusion pumps is not feasible in our environment due to their high costs and yet the current use of mini dextrose boluses with syringes as adapted at Mulago national referral and tertiary teaching hospital has unknown efficacy in prevention of hypoglycemia. We determined the efficacy of dextrose infusions by burettes versus two hourly dextrose boluses in prevention of hypoglycemia among preterms admitted in the first 72 hours at Special Care Unit, Mulago Hospital. One hundred and forty preterms aged 0 to 24 hours of life were randomized to receive 10% IV dextrose either as mini boluses or by infusion using burettes in an open label clinical trial. Blood glucose was measured at 0, two hourly for next 6 hours, 6 hourly for next 12 hours and thereafter 12 hourly until end of 72 hours following admission. Primary end point was incidence of hypoglycemia (random blood sugar (RBS) dextrose infusion was computed using 1-RR. From February 2012 to April 2012, 68 preterms in the bolus arm and 72 in the infusion arm were studied. Hypoglycemia was detected in 34% (48/140). The incidence of hypoglycemia in the bolus arm was 59% (40/68) compared to 11% (8/72) in the infusion arm (RR; 0.19, 95% CI; 0.09-0.37). Efficacy (1-RR) of infusion by burettes versus boluses in prevention of hypoglycemia among preterms was 0.81 (95% CI; 0.63-0.90). Continuous 10% dextrose infusion by burettes reduced the incidence of hypoglycemia by 81% in the first 72 hours of admission compared to two hourly 10% mini dextrose boluses among preterms admitted at Special Care Unit, Mulago Hospital. (ClinicalTrials.gov Identifier: NCT01688674).

  7. Bolus and continuous infusion mitoxantrone in newly diagnosed adult acute lymphoblastic leukemia: results of two consecutive phase II clinical studies.

    Science.gov (United States)

    Koc, Y; Akpek, G; Kansu, E; Kars, A; Tekuzman, G; Baltali, E; Güler, N; Barista, I; Güllü, I; Ozisik, Y; Firat, D

    1998-01-01

    Two consecutive phase II clinical studies were designed to evaluate the efficacy and safety of bolus and continuous infusion (CI) mitoxantrone (MTZ) in 39 patients with newly diagnosed acute lymphocytic leukemia (ALL). MTZ was used as part of the classical ALL induction regimen. Twenty patients were treated with bolus MTZ (10 mg/m2 for 3 days) combined with vincristine and prednisone. The same regimen was given to a second set of 19 patients, except that MTZ was administered as a 24-hr CI. Both groups received bimonthly intensifications with vincristine and prednisone for 3 years, along with oral maintenance therapy. Patients in the CI-MTZ study arm received additional MTZ on the first day of intensification cycles. Seventeen patients (85%) in the bolus arm and 15 patients (79%) in the CI arm achieved complete remission (CR). Median disease-free survivals (DFS) in the bolus and CI groups were 11 and 15 months after median follow-ups of 16 (3.5-96) and 13 (2.3-32) months, respectively. At 2.5 years, DFS rates were 29.4% and 34.4% in the bolus and CI groups (p > 0.05). There were no significant differences between two groups in rates of early death, degree of organ toxicity, or duration of neutropenia and thrombocytopenia. Significant cardiac toxicity was not observed in either group. Bolus or CI administration of MTZ was equally effective and was well tolerated. Neither the mode of administration nor increasing the dose intensity of MTZ by incorporating intensification cycles reduced relapse rates. Development of new antileukemia agents and novel treatment approaches are still needed to improve the high relapse rates in adult ALL once a complete response is achieved.

  8. Lung disease severity in idiopathic pulmonary fibrosis is more strongly associated with impedance measures of bolus reflux than pH parameters of acid reflux alone.

    Science.gov (United States)

    Gavini, S; Borges, L F; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W

    2017-05-01

    Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF). Pathogenesis may be related to chronic micro-aspiration. We aimed to assess objective measures of GER on multichannel intraluminal impedance and pH study (MII-pH) and their relationship with pulmonary function testing (PFT) results, and to compare the performance of pH/acid reflux parameters vs corresponding MII/bolus parameters in predicting pulmonary dysfunction in IPF. This was a retrospective cohort study of IPF patients undergoing prelung transplant evaluation with MII-pH off acid suppression, and having received PFT within 3 months. Patients with prior fundoplication were excluded. Severe pulmonary dysfunction was defined using diffusion capacity of the lung for carbon monoxide (DLCO) ≤40%. Six pH/acid reflux parameters with corresponding MII/bolus reflux measures were specified a priori. Multivariate analyses were applied using forward stepwise logistic regression. Predictive value of each parameter for severe pulmonary dysfunction was calculated by area-under-the-receiver-operating-characteristic-curve or c-statistic. Forty-five subjects (67% M, age 59, 15 mild-moderate vs 30 severe) met criteria for inclusion. Patient demographics and clinical characteristics were similar between pulmonary dysfunction groups. Abnormal total reflux episodes and prolonged bolus clearance time were significantly associated with pulmonary dysfunction severity on univariate and multivariate analyses. No pH parameters were significant. The c-statistic of each pH parameter was lower than its MII counterpart in predicting pulmonary dysfunction. MII/bolus reflux, but not pH/acid reflux, was associated with pulmonary dysfunction in prelung transplant patients with IPF. MII-pH may be more valuable than pH testing alone in characterizing GER in IPF. © 2016 John Wiley & Sons Ltd.

  9. Appropriateness of Bolus Antihypertensive Therapy for Elevated Blood Pressure in the Emergency Department.

    Science.gov (United States)

    Miller, Joseph B; Arter, Andrew; Wilson, Suprat S; Janke, Alexander T; Brody, Aaron; Reed, Brian P; Levy, Phillip D

    2017-08-01

    While moderate to severely elevated blood pressure (BP) is present in nearly half of all emergency department (ED) patients, the incidence of true hypertensive emergencies in ED patients is low. Administration of bolus intravenous (IV) antihypertensive treatment to lower BP in patients without a true hypertensive emergency is a wasteful practice that is discouraged by hypertension experts; however, anecdotal evidence suggests this occurs with relatively high frequency. Accordingly, we sought to assess the frequency of inappropriate IV antihypertensive treatment in ED patients with elevated BP absent a hypertensive emergency. We performed a retrospective cohort study from a single, urban, teaching hospital. Using pharmacy records, we identified patients age 18-89 who received IV antihypertensive treatment in the ED. We defined treatment as inappropriate if documented suspicion for an indicated cardiovascular condition or acute end-organ injury was lacking. Data abstraction included adverse events and 30-day readmission rates, and analysis was primarily descriptive. We included a total of 357 patients over an 18-month period. The mean age was 55; 51% were male and 93% black, and 127 (36.4%) were considered inappropriately treated. Overall, labetalol (61%) was the most commonly used medication, followed by enalaprilat (18%), hydralazine (18%), and metoprolol (3%). There were no significant differences between appropriate and inappropriate BP treatment groups in terms of clinical characteristics or adverse events. Hypotension or bradycardia occurred in three (2%) patients in the inappropriate treatment cohort and in two (1%) patients in the appropriately treated cohort. Survival to discharge and 30-day ED revisit rates were equivalent. More than one in three patients who were given IV bolus antihypertensive treatment in the ED received such therapy inappropriately by our definition, suggesting that significant resources could perhaps be saved through education of

  10. Appropriateness of Bolus Antihypertensive Therapy for Elevated Blood Pressure in the Emergency Department

    Directory of Open Access Journals (Sweden)

    Joseph B. Miller

    2017-07-01

    Full Text Available Introduction: While moderate to severely elevated blood pressure (BP is present in nearly half of all emergency department (ED patients, the incidence of true hypertensive emergencies in ED patients is low. Administration of bolus intravenous (IV antihypertensive treatment to lower BP in patients without a true hypertensive emergency is a wasteful practice that is discouraged by hypertension experts; however, anecdotal evidence suggests this occurs with relatively high frequency. Accordingly, we sought to assess the frequency of inappropriate IV antihypertensive treatment in ED patients with elevated BP absent a hypertensive emergency. Methods: We performed a retrospective cohort study from a single, urban, teaching hospital. Using pharmacy records, we identified patients age 18–89 who received IV antihypertensive treatment in the ED. We defined treatment as inappropriate if documented suspicion for an indicated cardiovascular condition or acute end-organ injury was lacking. Data abstraction included adverse events and 30-day readmission rates, and analysis was primarily descriptive. Results: We included a total of 357 patients over an 18-month period. The mean age was 55; 51% were male and 93% black, and 127 (36.4% were considered inappropriately treated. Overall, labetalol (61% was the most commonly used medication, followed by enalaprilat (18%, hydralazine (18%, and metoprolol (3%. There were no significant differences between appropriate and inappropriate BP treatment groups in terms of clinical characteristics or adverse events. Hypotension or bradycardia occurred in three (2% patients in the inappropriate treatment cohort and in two (1% patients in the appropriately treated cohort. Survival to discharge and 30-day ED revisit rates were equivalent. Conclusion: More than one in three patients who were given IV bolus antihypertensive treatment in the ED received such therapy inappropriately by our definition, suggesting that significant

  11. Continuous Transversus Abdominis Plane Nerve Blocks: Does Varying Local Anesthetic Delivery Method-Automatic Repeated Bolus Versus Continuous Basal Infusion-Influence the Extent of Sensation to Cold?: A Randomized, Triple-Masked, Crossover Study in Volunteers.

    Science.gov (United States)

    Khatibi, Bahareh; Said, Engy T; Sztain, Jacklynn F; Monahan, Amanda M; Gabriel, Rodney A; Furnish, Timothy J; Tran, Johnathan T; Donohue, Michael C; Ilfeld, Brian M

    2017-04-01

    It remains unknown whether continuous or scheduled intermittent bolus local anesthetic administration is preferable for transversus abdominis plane (TAP) catheters. We therefore tested the hypothesis that when using TAP catheters, providing local anesthetic in repeated bolus doses increases the cephalad-caudad cutaneous effects compared with a basal-only infusion. Bilateral TAP catheters (posterior approach) were inserted in 24 healthy volunteers followed by ropivacaine 2 mg/mL administration for a total of 6 hours. The right side was randomly assigned to either a basal infusion (8 mL/h) or bolus doses (24 mL administered every 3 hours for a total of 2 bolus doses) in a double-masked manner. The left side received the alternate treatment. The primary end point was the extent of sensory deficit as measured by cool roller along the axillary line at hour 6 (6 hours after the local anesthetic administration was initiated). Secondary end points included the extent of sensory deficit as measured by cool roller and Von Frey filaments along the axillary line and along a transverse line at the level of the anterior superior iliac spine at hours 0 to 6. Although there were statistically significant differences between treatments within the earlier part of the administration period, by hour 6 the difference in extent of sensory deficit to cold failed to reach statistical significance along the axillary line (mean = 0.9 cm; SD = 6.8; 95% confidence interval -2.0 to 3.8; P = .515) and transverse line (mean = 2.5 cm; SD = 10.1; 95% confidence interval -1.8 to 6.8; P = .244). Although the difference between treatments was statistically significant at various early time points for the horizontal, vertical, and estimated area measurements of both cold and mechanical pressure sensory deficits, no comparison remained statistically significant by hour 6. No evidence was found in this study involving healthy volunteers to support the hypothesis that changing the local anesthetic

  12. Flow injection gas chromatography with sulfur chemiluminescence detection for the analysis of total sulfur in complex hydrocarbon matrixes.

    Science.gov (United States)

    Hua, Yujuan; Hawryluk, Myron; Gras, Ronda; Shearer, Randall; Luong, Jim

    2018-01-01

    A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual-plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample-to-sample time ideal for fast analysis or trace sulfur analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Precision flow-controlled rubidium-82 generator for bolus and constant infusion studies

    International Nuclear Information System (INIS)

    Yano, Y.

    1981-01-01

    A unique flow rate controller and large reservoir pumping system have been developed for infusing rubidium-82 intravenously at bolus, constant, or variable infusion rates. Using rubidium-82 and the positron ring detector tomograph, extraction or flow information can be obtained in studies of the heart, head, or kidneys

  14. Use of 3D printers to create a patient‐specific 3D bolus for external beam therapy

    Science.gov (United States)

    Baker, Jamie; Hsia, An Ting; Xu, Zhigang

    2015-01-01

    The purpose of this paper is to demonstrate that an inexpensive 3D printer can be used to manufacture patient‐specific bolus for external beam therapy, and to show we can accurately model this printed bolus in our treatment planning system for accurate treatment delivery. Percent depth‐dose measurements and tissue maximum ratios were used to determine the characteristics of the printing materials, acrylonitrile butadiene styrene and polylactic acid, as bolus material with physical density of 1.04 and 1.2 g/cm3, and electron density of 3.38×1023electrons/cm3 and 3.80×1023 electrons/cm3, respectively. Dose plane comparisons using Gafchromic EBT2 film and the RANDO phantom were used to verify accurate treatment planning. We accurately modeled a printing material in Eclipse treatment planning system, assigning it a Hounsfield unit of 260. We were also able to verify accurate treatment planning using gamma analysis for dose plane comparisons. With gamma criteria of 5% dose difference and 2 mm DTA, we were able to have 86.5% points passing, and with gamma criteria of 5% dose difference and 3 mm DTA, we were able to have 95% points passing. We were able to create a patient‐specific bolus using an inexpensive 3D printer and model it in our treatment planning system for accurate treatment delivery. PACS numbers: 87.53.Jw, 87.53.Kn, 87.56.ng PMID:26103485

  15. Tolerance to continuous intrathecal baclofen infusion can be reversed by pulsatile bolus infusion

    NARCIS (Netherlands)

    Heetla, H. W.; Staal, M. J.; van Laar, T.

    Study design: Pilot study. Objective: To study the effect of pulsatile bolus infusion of intrathecal baclofen (ITB) on daily ITB dose, in patients showing dose increases, probably due to tolerance. Setting: Department of neurology and neurosurgery, University Medical Center Groningen, the

  16. Dosimetric verification of helical tomotherapy for total scalp irradiation

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Soisson, Emilie; Metcalfe, Peter; Rosenfeld, Anatoly B.; Tome, Wolfgang A.

    2008-01-01

    Total scalp irradiation is a treatment technique used for a variety of superficial malignancies. Helical tomotherapy is an effective technique used for total scalp irradiation. Recent published work has shown the TomoTherapy planning system to overestimate the superficial dose. In this study, the superficial doses for a helical tomotherapy total scalp irradiation have been measured on an anthropomorphic phantom using radiochromic and radiographic film as well as a new skin dosimeter, the MOSkin. The superficial dose was found to be accurately calculated by the TomoTherapy planning system. This is in contrast to recent reports, probably due to a combination of the smaller dose grid resolution used in planning and this particular treatment primarily consisting of beamlets tangential to the scalp. The superficial dose was found to increase from 33.6 to 41.2 Gy and 36.0 to 42.0 Gy over the first 2 mm depth in the phantom in selected regions of the PTV, measured with radiochromic film. The prescription dose was 40 Gy. The superficial dose was at the prescription dose or higher in some regions due to the bolus effect of the thermoplastic head mask and the head rest used to aid treatment setup. It is suggested that to achieve the prescription dose at the surface (≤2 mm depth) bolus or a custom thermoplastic helmet is used.

  17. Remifentanil Prevents Withdrawal Movements Caused by Intravenous Injection of Rocuronium

    Science.gov (United States)

    Choi, Byung In; Choi, Seung Ho; Shin, Yang-Sik; Lee, Sung Jin; Yoon, Kyung Bong; Shin, Seo Kyung

    2008-01-01

    Purpose The incidence of pain induced withdrawal movement following intravenous injection of rocuronium is high. This randomized, double-blind, placebo-controlled study was designed to evaluate the effect of pretreatment of remifentanil on the withdrawal movements due to intravenous injection of rocuronium during anesthetic induction. Materials and Methods Ninety adult female patients undergoing thyroidectomy were randomly allocated to three groups. Each patient intravenously received one of three solutions of equal volume (4 mL): normal saline (Group I, n = 30), 0.5 µg/kg remifentanil (Group II, n = 30) or 1 µg/kg remifentanil (Group III, n = 30). Thirty seconds after remifentanil administration, anesthesia was induced with 5 mg/kg IV thiopental. Twenty seconds after thiopental injection, 0.6 mg/kg IV rocuronium was administered (injection rate of 0.5 mL/sec) and patients' withdrawal movements were assessed. Mean arterial pressure (MAP) and heart rate were assessed on arrival in the operation room, before the tracheal intubation and immediately, 1 and 2 min after the tracheal intubation. Results The incidence of withdrawal movements was significantly lower in both of the remifentanil groups (3 and 0% in Group II and III, respectively) than in the saline group (70%). Remifentanil attenuated the increase of heart rate and MAP immediately and 1 min after the tracheal intubation. Conclusion The pretreatment with 0.5 and 1.0 µg/kg remifentanil of bolus doses prevented the withdrawal movements caused by rocuronium injection, and effectively blunted cardiovascular activation following tracheal intubation. PMID:18452256

  18. SU-F-T-86: Electron Dosimetric Effects of Bolus and Lens Shielding in Treating Superficial Eye Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Young, L [University of Washington Medical Center, Seattle, WA (United States); Wootton, L [University of Washington School of Medicine, Seattle, WA (United States); Gopan, O; Liao, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: Electron therapy for the treatment of ocular lymphomas requires the lens to be shielded to prevent secondary cataracts. This work evaluates the dosimetry under a suspended eyeshield with and without bolus for low energy electron fields. Methods: Film (GafChromic EBT3) dosimetry and relative output factors were measured for 6, 8, and 10 MeV electron energies. A customized 5 cm diameter circle electron orbital cutout was constructed for a 6×6 cm applicator with a lens shield, 1 cm diameter Cerrobend cylinder with 2.2 cm length, suspended from an XV film covering the open field. Relative output factors were measured using a Scanditronix electron diode in a solid water phantom. Depth dose profiles were collected for bolus thicknesses of 0, 3, and 5 mm in solid water at a source to surface distance (SSD) of 100 cm. These measurements were repeated in a Rando phantom. Results: At 5 mm, the approximate distance of the lens from the surface of the cornea, the estimated dose in solid water under the suspended lens shield was reduced to 16%, 14%, and 13% of the unblocked dose at the same depth, for electron energies of 6, 8, and 10 MeV, respectively. Applying bolus increased estimated doses under the block to 22% for 3-mm and 32% for 5-mm thicknesses for a 6 MeV incident electron beam. This effect is reduced for higher energies where the corresponding values were 15.5% and 18% for 3-mm and 5-mm for an 8 MeV electron beam. Conclusion: The application of bolus to treat superficial eye lesions of the conjunctiva increases lens dose at a depth of 5-mm under the shielding block with decreasing electron energy. Careful selection of electron energy is needed to account for electron scatter under the lens shield with the application of bolus in order to prevent cataracts.

  19. Intrathecal chemotherapy for refractory disseminated medulloblastoma.

    Science.gov (United States)

    Yoshimura, Junichi; Nishiyama, Kenichi; Mori, Hiroshi; Takahashi, Hideaki; Fujii, Yukihiko

    2008-05-01

    To analyze the effect of intrathecal (IT) chemotherapy for disseminated medulloblastoma. Twenty-one patients received IT chemotherapy using the chemotherapeutic agents of methotrexate (MTX) and nitrosoureas (ACNU, MCNU) including nine patients for residual leptomeningeal lesions after initial surgery and radiation, and 12 for a recurrence with leptomeningeal dissemination. Of these 21 patients, 12 received a lumbar and/or ventricular bolus injection of the chemotherapeutic agents, one received the ventriculolumbar perfusion of the agents, and eight received both the perfusion and bolus injection. The doses ranged from 6-7 mg/m(2) of ACNU for perfusion and 3-3.5 mg/m(2) of ACNU, MCNU, or MTX for the bolus injection, and the cycles were administered from 3 to 12 times for perfusion and from 5 to 54 times for the bolus injection. The effects of chemotherapy were assessed by both radiological and cytological examinations, and the clinical symptoms were also assessed. Radiological and/or cytological responses were observed in 10 of 21 patients (47.6%), including seven cases demonstrating a complete remission. The 5-year overall survival rate and 5-year survival rate after dissemination were 61.5 and 46.4%, respectively. Five patients who received a lumbar bolus injection of nitrosoureas experienced paraplegia and double incontinence. One patient who received a ventricular injection of nitrosoureas experienced truncal ataxia. IT chemotherapy was found to be effective in some cases with refractory disseminated medulloblastoma and it seems to be an appropriate treatment choice for leptomeningeal recurrence. However, the frequent bolus injections of nitrosoureas should be avoided to prevent the side effects.

  20. Comparative study of intravenous urographic bolus (I.U.B.) and intravenous urographic infusion (I.U.I.) in dogs

    International Nuclear Information System (INIS)

    Thibaut L, Julio; Ditzel, G.; Vargas, L; Born, R; Deppe G, Rodolfo

    1996-01-01

    Two urographic methods were compared: the intravenous urographic bolus (i.u.b.) and the intravenous urographic infusion (i.u.i.). In both methods, two groups of seven healthy adult dogs of both sexes, weighing7.0 to 16.5 kg were used and were anaesthesized with 2% thiopentone sodium in doses of 20 mg/kg via cephalica. In the i.u.b., meglumine diatrizoate (Hypaque-M, 60%) was injected via saphena with a concentration of 282 mg of iodine per mi in doses of 564 mg of iodine per kg. In the i.u.i., meglumine diatrizoate was injected via saphena by drip infusion with a concentration of 200 mg of iodine per mi in doses of 500 mg of iodine per kg. Three series of two X-rays each were taken in ventrodorsal projection 1, 4 and 8 min and left lateral recumbency 30 sec after administering the contrast medium. The X-ray plates obtained were analyzed and compared intra and inter group considering the advance speed of the contrast medium, the radiographic density and outline, and kidney size. The advance speed of the contrast medium was higher in the i.u.i., reaching the kidney, ureter and bladder 1 min after administration in both projections; in ventrodorsal projections in the i.u.b. only the kidneys were reached while in the left lateral recumbency, the kidney and ureters were reached [es

  1. The effect of food bolus location on jaw movement smoothness and masticatory efficiency

    NARCIS (Netherlands)

    Molenaar, W.N.B.; Gezelle Meerburg, P.J.; Luraschi, J.; Whittle, T.; Schimmel, M.; Lobbezoo, F.; Peck, C.C.; Murray, G.M.; Minami, I.

    2012-01-01

    Masticatory efficiency in individuals with extensive tooth loss has been widely discussed. However, little is known about jaw movement smoothness during chewing and the effect of differences in food bolus location on movement smoothness and masticatory efficiency. The aim of this study was to

  2. Total and regional deposition of inhaled aerosols in supine healthy subjects and subjects with mild-to-moderate COPD

    Energy Technology Data Exchange (ETDEWEB)

    Darquenne, Chantal; Lamm, Wayne J.; Fine, Janelle M.; Corley, Richard A.; Glenny, Robb W.

    2016-09-01

    Despite substantial development of sophisticated subject-specific computational models of aerosol transport and deposition in human lungs, experimental validation of predic- tions from these new models is sparse. We collected aerosol retention and exhalation profiles in seven healthy volunteers and six subjects with mild-to-moderate COPD (FEV1 ¼ 50–80%predicted) in the supine posture. Total deposition was measured during continuous breathing of 1 and 2.9 mm-diameter particles (tidal volume of 1 L, flow rate of 0.3 L/s and 0.75 L/s). Bolus inhalations of 1 mm particles were performed to penetration volumes of 200, 500 and 800 mL (flow rate of 0.5 L/s). Aerosol bolus dispersion (H), deposition, and mode shift (MS) were calculated from these data. There was no significant difference in total deposition between healthy subjects and those with COPD. Total deposition increased with increasing particle size and also with increasing flow rate. Similarly, there was no significant difference in aerosol bolus deposition between subject groups. Yet, the rate of increase in dispersion and of decrease in MS with increasing penetration volume was higher in subjects with COPD than in healthy volunteers (H: 0.79870.205 vs. 0.52770.122 mL/mL, p¼ 0.01; MS: - 0.27170.129 vs. - 0.145 70.076 mL/mL, p¼ 0.05) indicating larger ventilation inhomogeneities (based on H) and increased flow sequencing (based on MS) in the COPD than in the healthy group. In conclusion, in the supine posture, deposition appears to lack sensitivity for assessing the effect of lung morphology and/or ventilation distribution alteration induced by mild-to- moderate lung disease on the fate of inhaled aerosols. However, other parameters such as aerosol bolus dispersion and mode shift may be more sensitive parameters for evaluating models of lungs with moderate disease.

  3. An alternative scanning protocol to eliminate perivenous streak artifacts in thoracic spiral computed tomography. The usefulness of ankle vein contrast injection

    International Nuclear Information System (INIS)

    Hara, Masaki; Ogino, Hiroyuki; Itoh, Masato; Ohba, Satoru; Andoh, Keiichi; Kitase, Masanori; Goodman, P.C.

    2001-01-01

    The purpose of this study was to eliminate perivenous streak artifact from contrast-enhanced thoracic spiral CT using superficial ankle vein injection (ankle vein method). Forty-four consecutive inpatients had thoracic spiral CT following ankle vein method and were compared to 30 patients who had conventional antecubital vein injection. Non-ionic 300 mg/mL contrast material were injected at 1-1.5 mL/sec with a power injector. Twenty mL of normal saline was injected immediately thereafter as a flushing bolus. Qualitative scores of perivenous artifact (1 to 5=extensive) and vascular enhancement (1 to 5=excellent) were recorded. Complications were investigated clinically. The mean score of perivenous artifact was 1 with the ankle vein method and 4.4 with the conventional method (P<.0001). Scores of pulmonary artery opacification were almost equal (4.2 and 4.5 respectively, P=.11). No complications were observed. The ankle vein method is an effective method to prevent perivenous artifact during thoracic spiral CT. (author)

  4. Continuous versus bolus intragastric tube feeding for preterm and low birth weight infants with gastro-oesophageal reflux disease.

    Science.gov (United States)

    Richards, Robyn; Foster, Jann P; Psaila, Kim

    2014-07-17

    Gastro-oesophageal reflux disease is a particularly common condition in preterm and low birth weight infants. These infants are also more likely to have excessive regurgitation, as they do not have a fully developed antireflux mechanism. Preterm and low birth weight infants who are unable to suck oral feeds are required to be fed via an intragastric tube for varying lengths of time. Intragastric tube feeding can be delivered by the intermittent bolus or continuous feeding method. Use of continuous or intermittent bolus intragastric feeding may have a positive or negative effect on the incidence or severity of gastro-oesophageal reflux disease. To determine whether continuous or intermittent bolus intragastric tube feeding reduces the number of episodes and the duration of gastro-oesophageal reflux disease (GORD) in preterm and low birth weight infants.We intended to perform subgroup analyses for gestational age; birth weight; age in days from birth at full enteral feeding via intragastric tube (breast vs bottle); frequency of intermittent bolus feed; and type of medication for treatment of GORD (only if medication prescribed and given similarly to both intervention groups). We used the standard search strategy of the Cochrane Neonatal Group as described in The Cochrane Library (www.thecochranelibrary.com) to search for randomised controlled trials (RCTs) in the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE (1966 to September 2013), EMBASE (1980 to September 2013) and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) (1982 to September 2013). We also searched previous reviews, including cross-references, abstracts and conference and symposia proceedings of the Perinatal Society of Australia and New Zealand and the Pediatric Academic Societies (American Pediatric Society/Society for Pediatric Research and European Society for Paediatric Research) from 1990 to 2012. Published and unpublished RCTs and quasi

  5. The cost-effectiveness and budget impact of stepwise addition of bolus insulin in the treatment of type 2 diabetes: evaluation of the FullSTEP trial.

    Science.gov (United States)

    Saunders, Rhodri; Lian, Jean; Karolicki, Boris; Valentine, William

    2014-12-01

    Abstract Background and aims: Intensification of basal insulin-only therapy in type 2 diabetes is often achieved through addition of bolus insulin 3-times daily. The FullSTEP trial demonstrated that stepwise addition (SWA) of bolus insulin aspart was non-inferior to full basal-bolus (FBB) therapy and reduced the rate of hypoglycemia. Here the cost-effectiveness and budget impact of SWA is evaluated. Cost-effectiveness and budget impact models were developed to assess the cost and quality-of-life (QoL) implications of intensification using SWA compared with FBB in the US setting. At assessment, SWA patients added one bolus dose to their current regimen if the HbA1c target was not met. SWA patients reaching three bolus doses used FBB event rates. Outcomes were evaluated at trial end and projected annually up to 5 years. Models captured hypoglycemic events, the proportion meeting HbA1c target, and self-measured blood glucose. Event rates and QoL utilities were taken from trial data and published literature. Costs were evaluated from a healthcare-payer perspective, reported in 2013 USD, and discounted (like clinical outcomes) at 3.5% annually. This analysis applies to patients with HbA1c 7.0-9.0% and body mass index Budget impact analysis estimated that, by moving from FBB to SWA, a health plan with 77,000 patients with type 2 diabetes, of whom 7.8% annually intensified to basal-bolus therapy, would save USD 1304 per intensifying patient over the trial period. SWA of bolus insulin should be considered a beneficial and cost-saving alternative to FBB therapy for the intensification of treatment in type 2 diabetes.

  6. Efficiency of Cardiotropic Therapy in Neonatal Infants with Posthypoxic Myocardial Damage

    Directory of Open Access Journals (Sweden)

    Yu. N. Belova

    2011-01-01

    Full Text Available Objective: to define the optimal tranexamic acid dosage regimen to reduce perioperative blood loss during total endo-prosthetic hip joint replacement (TEHJR. Subjects and methods. A randomized controlled trial enrolled 90 patients admitted for elective primary cementless TEHJR. Prior to surgery, all the patients were given an intravenous bolus injection of tranexamic acid in a dose of 1 g. A day before surgery, the patients were divided into 3 groups of 30 subjects each. In Group 1, tranexamic acid was administered only before incision of the skin. In Group 2, a second bolus of tranexamic acid 1 g was injected 3 hours after start of surgery. In Group 3, 1 g of tranexamic acid was readminis-tered 6 hours following surgery if drainage blood loss volume exceeded 200 ml. Results. No statistically significant differences were found between the study patient groups in terms of the amount of blood loss, the blood levels of hemoglobin, needs for hemotransfusion therapy, and the frequency of postoperative complications. Conclusion. A second bolus of tranexamic acid 1 g does not reduce the amount of blood loss as compared to a single preoperative bolus dose of tranexamic acid 1 g during elective primary cementless TEHJP. Key words: tranexamic acid, endoprosthetic hip joint replacement, blood loss.

  7. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  8. Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Michelle M., E-mail: mmkim@mdanderson.org [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Kudchadker, Rajat J.; Kanke, James E.; Zhang, Sean; Perkins, George H. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States)

    2012-07-01

    The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.

  9. Experiences with Lean Six Sigma as improvement strategy to reduce parenteral medication administration errors and associated potential risk of harm.

    Science.gov (United States)

    van de Plas, Afke; Slikkerveer, Mariëlle; Hoen, Saskia; Schrijnemakers, Rick; Driessen, Johanna; de Vries, Frank; van den Bemt, Patricia

    2017-01-01

    In this controlled before-after study the effect of improvements, derived from Lean Six Sigma strategy, on parenteral medication administration errors and the potential risk of harm was determined. During baseline measurement, on control versus intervention ward, at least one administration error occurred in 14 (74%) and 6 (46%) administrations with potential risk of harm in 6 (32%) and 1 (8%) administrations. Most administration errors with high potential risk of harm occurred in bolus injections: 8 (57%) versus 2 (67%) bolus injections were injected too fast with a potential risk of harm in 6 (43%) and 1 (33%) bolus injections on control and intervention ward. Implemented improvement strategies, based on major causes of too fast administration of bolus injections, were: Substitution of bolus injections by infusions, education, availability of administration information and drug round tabards. Post intervention, on the control ward in 76 (76%) administrations at least one error was made (RR 1.03; CI95:0.77-1.38), with a potential risk of harm in 14 (14%) administrations (RR 0.45; CI95:0.20-1.02). In 40 (68%) administrations on the intervention ward at least one error occurred (RR 1.47; CI95:0.80-2.71) but no administrations were associated with a potential risk of harm. A shift in wrong duration administration errors from bolus injections to infusions, with a reduction of potential risk of harm, seems to have occurred on the intervention ward. Although data are insufficient to prove an effect, Lean Six Sigma was experienced as a suitable strategy to select tailored improvements. Further studies are required to prove the effect of the strategy on parenteral medication administration errors.

  10. Alfaxalone for maintenance of anaesthesia in ponies undergoing field castration: continuous infusion compared with intravenous boluses.

    Science.gov (United States)

    Deutsch, Julia; Ekiri, Abel; de Vries, Annemarie

    2017-07-01

    To compare alfaxalone as continuous intravenous (IV) infusion with intermittent IV injections for maintenance of anaesthesia in ponies undergoing castration. Prospective, randomized, 'blinded' clinical study. A group of 33 entire male Welsh ponies undergoing field castration. After preanaesthetic medication with IV detomidine (10 μg kg -1 ) and butorphanol (0.05 mg kg -1 ), anaesthesia was induced with IV diazepam (0.05 mg kg -1 ) followed by alfaxalone (1 mg kg -1 ). After random allocation, anaesthesia was maintained with either IV alfaxalone 2 mg kg -1  hour -1 (group A; n = 16) or saline administered at equal volume (group S; n = 17). When necessary, additional alfaxalone (0.2 mg kg -1 ) was administered IV. Ponies were breathing room air. Using simple descriptive scales, surgical conditions and anaesthesia recovery were scored. Total amount of alfaxalone, ponies requiring additional alfaxalone and time to administration, time from induction to end of infusion and end of infusion to standing were noted. Indirect arterial blood pressure, pulse and respiratory rates, end-expiratory carbon dioxide partial pressure and arterial haemoglobin oxygen saturation were recorded every 5 minutes. Data were analysed using Student t, Mann-Whitney U and chi-square tests, where appropriate (p < 0.05). Total amount of alfaxalone administered after induction of anaesthesia (0.75 ± 0.27 versus 0.17 ± 0.23 mg kg -1 ; p < 0.0001) and time to standing (14.8 ± 4 versus 11.6 ± 4 minutes; p = 0.044) were higher in group A compared to group S. Ponies requiring additional alfaxalone boluses [four (group A) versus seven (group S)] and other measured variables were similar between groups; five ponies required oxygen supplementation [three (group A) versus two (group S)]. Continuous IV infusion and intermittent administration of alfaxalone provided similar anaesthesia quality and surgical conditions in ponies undergoing field castration. Less alfaxalone

  11. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K [University of Maryland School of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.

  12. SU-E-T-71: A Radiochromic Film Based Quantitative Assessment of Thermoplastic Mask Bolus Effect in Head and Neck IMRT/VMAT

    International Nuclear Information System (INIS)

    Kalavagunta, C; Lin, M; Snider, J; Xu, H; Schrum, A; Vadnais, P; Marter, K; Suntharalingam, M; Prado, K

    2015-01-01

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between mask and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization

  13. Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT

    International Nuclear Information System (INIS)

    Yanaga, Yumi; Awai, Kazuo; Nakayama, Yoshiharu; Nakaura, Takeshi; Tamura, Yoshitaka; Yamashita, Yasuyuki; Funama, Yoshinori; Aoyama, Masahito; Asada, Naoki

    2007-01-01

    The aim of this study was to investigate the optimal dose and injection duration of contrast material (CM) for depicting hypervascular hepatocellular carcinomas (HCCs) during the hepatic arterial phase with multidetector row computed tomography (CT). The study population consisted of 71 patients with hypervascular HCCs. After unenhanced scans, the first (early arterial phase, or EAP), second (late arterial phase, or LAP), and third (equilibrium phase) scanning was started at 30, 43, and 180 s after injection of contrast material (CM). During a 33-s period, patients with a body weight ≤50 kg received 100 ml of non-ionic CM with an iodine concentration of 300 mgI/ml; patients whose body weight was >50 kg received 100 ml of CM with an iodine concentration of 370 mgI/ml. First, we measured enhancement in the abdominal aorta and tumor-to-liver contrast (TLC) during the EAP and LAP. Next, to investigate the relation between aortic enhancement and TLC during the LAP, two radiologists visually assessed the conspicuity of hypervascular HCCs during the LAP using a 3-point scale: grade 1, poor; grade 2, fair; grade 3, excellent. Finally, to examine the effect of the CM dose and injection duration on aortic enhancement during the EAP, we simulated aortic enhancement curves using test bolus data obtained for 10 HCC patients and the method of Fleischmann and Hittmair. A relatively strong correlation was observed between aortic enhancement during the EAP and TLC during the LAP (correlation coefficient r=0.75, P 280 HU for aortic enhancement simulations during EAP, the injection duration should be <25 s for patients receiving a CM dose of 1.7 ml/kg with 300 mgI/ml iodine and <30 s for those receiving 2.0 ml/kg. For excellent depiction of hypervascular HCCs during the hepatic arterial phase, the injection duration should be <25 s in patients receiving a CM dose of 1.7 ml/kg with 300 mgI/ml iodine and <30 s for patients receiving 2.0 ml/kg. (author)

  14. Enhancing automatic closed-loop glucose control in type 1 diabetes with an adaptive meal bolus calculator - in silico evaluation under intra-day variability.

    Science.gov (United States)

    Herrero, Pau; Bondia, Jorge; Adewuyi, Oloruntoba; Pesl, Peter; El-Sharkawy, Mohamed; Reddy, Monika; Toumazou, Chris; Oliver, Nick; Georgiou, Pantelis

    2017-07-01

    Current prototypes of closed-loop systems for glucose control in type 1 diabetes mellitus, also referred to as artificial pancreas systems, require a pre-meal insulin bolus to compensate for delays in subcutaneous insulin absorption in order to avoid initial post-prandial hyperglycemia. Computing such a meal bolus is a challenging task due to the high intra-subject variability of insulin requirements. Most closed-loop systems compute this pre-meal insulin dose by a standard bolus calculation, as is commonly found in insulin pumps. However, the performance of these calculators is limited due to a lack of adaptiveness in front of dynamic changes in insulin requirements. Despite some initial attempts to include adaptation within these calculators, challenges remain. In this paper we present a new technique to automatically adapt the meal-priming bolus within an artificial pancreas. The technique consists of using a novel adaptive bolus calculator based on Case-Based Reasoning and Run-To-Run control, within a closed-loop controller. Coordination between the adaptive bolus calculator and the controller was required to achieve the desired performance. For testing purposes, the clinically validated Imperial College Artificial Pancreas controller was employed. The proposed system was evaluated against itself but without bolus adaptation. The UVa-Padova T1DM v3.2 system was used to carry out a three-month in silico study on 11 adult and 11 adolescent virtual subjects taking into account inter-and intra-subject variability of insulin requirements and uncertainty on carbohydrate intake. Overall, the closed-loop controller enhanced by an adaptive bolus calculator improves glycemic control when compared to its non-adaptive counterpart. In particular, the following statistically significant improvements were found (non-adaptive vs. adaptive). Adults: mean glucose 142.2 ± 9.4vs. 131.8 ± 4.2mg/dl; percentage time in target [70, 180]mg/dl, 82.0 ± 7.0vs. 89.5 ± 4

  15. Hepatic 123I-insulin binding kinetics in non-insulin-dependent (Type 2) diabetic patients after i.v. bolus administration

    International Nuclear Information System (INIS)

    Oolbekkink, M.; Veen, E.A. van der; Heine, R.J.; Hollander, W. den; Nauta, J.J.P.

    1989-01-01

    Insulin binding kinetics in the liver were studied in non insulin dependent (Type 2) diabetic patients, by i.v. bolus administration of 123 I-insulin. Eight Type 2 diabetic patients were compared with six male volunteers. Uptake of 123 I-insulin by liver and kidneys was measured by dynamic scintigraphy with a gamma camera during 30 min. Images of liver and kidneys appeared within 2-3 min after administration of 123 I-insulin at a dose of 1 mCi (37 MBq). Peak radioactivity for the liver was found 7.5±0.2 and 6.9±0.3 min after injection for the healthy and the diabetic subjects, respectively (N.S.). The percentage 123 I-insulin hepatic uptake was not significantly different for the diabetic and the healthy subjects. Although a large variation exists for maximal uptake of radioactivity within both groups, the data suggest that binding differences in the liver in Type 2 diabetic patients, as compared to healthy subjects, may not account for hepatic insulin resistance. (orig.)

  16. Combustion characteristics of a gasoline engine with independent intake port injection and direct injection systems for n-butanol and gasoline

    International Nuclear Information System (INIS)

    He, Bang-Quan; Chen, Xu; Lin, Chang-Lin; Zhao, Hua

    2016-01-01

    Highlights: • Different injection approaches for n-butanol and gasoline affect combustion events. • High n-butanol percentage in the total energy of fuels improves combustion stability. • N-butanol promotes ignition and shortens combustion duration. • Lean burn increases indicated mean effective pressure at fixed total energy of fuels. • Different fuel injection methods slightly affect indicated mean effective pressure. - Abstract: N-butanol, as a sustainable biofuel, is usually used as a blend with gasoline in spark ignition engines. In this study, the combustion characteristics were investigated on a four-cylinder spark ignition gasoline engine with independent port fuel injection and direct injection systems for n-butanol and gasoline in different operating conditions. The results show that in the case of port fuel injection of n-butanol with direct injection gasoline at a given total energy released in a cycle, indicated mean effective pressure is slightly affected by spark timing at stoichiometry while it changes much more with delayed spark timing in lean burn conditions and is much higher in lean burn conditions compared to stoichiometry at given spark timings. With the increase of n-butanol percentage in a fixed total energy released in a cycle at given spark timings, ignition timing advances, combustion duration shortens, indicated mean effective pressure and indicated thermal efficiency increase. For the cases of port fuel injection of n-butanol with direction injection gasoline and port fuel injection of gasoline with direction injection n-butanol at a fixed total energy released in a cycle, their indicated mean effective pressures are close. But their combustion processes are dependent on fuel injection approaches.

  17. Meta-Analysis of the Clinical Value of Danshen Injection and Huangqi Injection in Liver Cirrhosis

    Directory of Open Access Journals (Sweden)

    Changtai Zhu

    2013-01-01

    Full Text Available Objective. To evaluate the clinical value of Danshen injection and Huangqi injection for the treatment of liver cirrhosis. Methods. The Chinese Biomedical Literature Database (CBM, Chinese Scientific Journals Full-Text Database (VIP, Wanfang Database, China National Knowledge Infrastructure (CNKI, PubMed, and EMBASE database were searched to collect the literatures about the randomized controlled trials involving the treatment of liver cirrhosis with Danshen injection combined with Huangqi injection, and the data analyses were performed using RevMan 4.2 software. Results. A total of 11 studies involving 1086 patients (trials group: 554 cases, control group: 532 cases were included in this study. Compared with those in control group, the meta-analysis showed-that the total effectiveness rate and the level of serum albumin increased, while serum total bilirubin, alanine transmninase, type III procollagen, hyaluronic acid, laminin, and type-IV collagen decreased in trials group. The Jadad score ranged from 1 to 2 and the funnel plot analysis suggests that publication bias may occur. Conclusions. Danshen injection combined with Huangqi injection may promote the curative efficacy of liver cirrhosis, which is a promising novel treatment approach. The exact outcome needs to perform rigorously designed, multicenter, and large randomized controlled trials.

  18. Lower esophageal mucosal ring: correlation of referred symptoms with radiographic findings using a marshmallow bolus.

    Science.gov (United States)

    Smith, D F; Ott, D J; Gelfand, D W; Chen, M Y

    1998-11-01

    The purpose of this investigation was to determine the prevalence of lower esophageal mucosal rings and to correlate the relationship between these mucosal rings and the presence and anatomic level of symptoms evoked using a marshmallow bolus. Our prospective study included 130 patients who underwent barium examination of the esophagus. All patients completed a questionnaire regarding the anatomic location of their symptoms of dysphagia. In addition to a multiphasic examination of the esophagus, all patients also underwent fluoroscopic observation and videotaping while swallowing a marshmallow bolus; any symptoms that were provoked were recorded. Lower esophageal mucosal rings were shown in 26 (20%) of the 130 patients. The diameter of the rings was 9-12 mm in six patients, 13-20 mm in 18 patients, and larger than 20 mm in two patients. In 16 (62%) of the 26 patients, a marshmallow bolus became impacted at the ring; the impaction caused dysphagia in 12 (75%) of the 16 patients. In these 12 patients, dysphagia was referred to the neck in seven, the sternal angle in two, the mid chest in two, and the lower chest in one patient. None of the 12 patients had a pharyngeal or cervical esophageal abnormality that would account for their symptoms. Because proximal referral of symptoms is common in patients with lower esophageal mucosal rings, a thorough radiographic examination of the entire esophagus and esophagogastric region is required regardless of the level of their swallowing complaints.

  19. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    International Nuclear Information System (INIS)

    Knox, Matthew K.; Rivers-Bowerman, Michael D.; Bardgett, Harry P.; Cowan, Nigel C.

    2010-01-01

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  20. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Matthew K. [University of Calgary, Faculty of Medicine, UME Office, Health Sciences Centre, Calgary, Alberta (Canada); Rivers-Bowerman, Michael D. [University of British Columbia, Faculty of Medicine, MD Undergraduate Program, Diamond Health Care Centre, Vancouver, British Columbia (Canada); Bardgett, Harry P. [Bradford Teaching Hospitals, Department of Radiology, Bradford (United Kingdom); Cowan, Nigel C. [The Churchill Hospital, Department of Radiology, Oxford (United Kingdom)

    2010-11-15

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  1. Acute intraoperative reactions during the injection of calcium sulfate bone cement for the treatment of unicameral bone cysts: a review of four cases.

    Science.gov (United States)

    Nystrom, Lukas; Raw, Robert; Buckwalter, Joseph; Morcuende, Jose A

    2008-01-01

    Unicameral bone cysts can predispose patients to pathologic fracture and deformities of growth. Treatment options vary from continuous decompression with transcortical placement of a cannulated screw to percutaneous aspiration and injection of medical-grade calcium sulfate. From 2005 to 2007, we treated 22 patients with unicameral bone cysts using aspiration and injection of calcium sulfate. Three patients experienced acute laryngospasm and one patient developed tachyarrhythmia, temporarily, associated with injection of calcium sulfate. All reactions occurred in patients under age 18 without predisposing risk factors and resolved spontaneously with supportive care. Although the mechanism is unclear, we hypothesize that these reactions are either due to the nociceptive stimulus of the calcium sulfate injection or a systemic calcium bolus. Clinicians using this product for this indication should be aware that such reactions may occur. We suggest endotracheal intubation and communication to the anesthesiologist about the time of the injection in preparation for these idiopathic responses. Further research is necessary to determine exactly how this reaction occurs and how it can be avoided.

  2. Tranexamic acid reduces blood loss and blood transfusions in primary total hip arthroplasty: a prospective randomized double-blind study in 40 patients

    DEFF Research Database (Denmark)

    Husted, Henrik; Blønd, Lars; Sonne-Holm, Stig

    2003-01-01

    INTRODUCTION: We performed a prospective, randomized, double-blind study on 40 patients scheduled for primary total hip arthroplasty due to arthrosis or osteonecrosis to determine the effect of tranexamic acid on per- and postoperative blood losses and on the number of blood transfusions needed....... PATIENTS AND METHODS: 40 patients were randomized to tranexamic acid (10 mg/kg given as a bolus intravenous injection, followed by a continuous infusion of 1 mg/kg/hour for 10 hours) or placebo (20 mL saline given intravenously) 15 minutes before the incision. We recorded the peroperative and postoperative...... blood losses at removal of the drain 24 hours after the operation and the number of blood transfusions. RESULTS: Patients receiving tranexamic acid had a mean peroperative blood loss of 480 mL versus 622 mL in patients receiving placebo (p = 0.3), a postoperative blood loss of 334 mL versus 609 mL (p...

  3. Effect of organic contrast Media on the haematology and Serum ...

    African Journals Online (AJOL)

    Key Words: Contrast media, haematology, serum electrolytes, dogs, xylazine. The effect of contrast media on the hematology and serum electrolyte was determined in five dogs sedated with 2mg/kg of xylazine intramuscular (i.m). A total of 800mg/kg bolus of 76% urograffin was then administered by intravenous injection ...

  4. Pathological bolus exposure may define gastro-esophageal reflux better than pathological acid exposure in patients with globus.

    Science.gov (United States)

    Sinn, Dong Hyun; Kim, Beom Jin; Son, Hee Jung; Kim, Jae J; Rhee, Jong Chul; Rhee, Poong-Lyul

    2012-01-01

    Conventionally, pathological acid exposure (PAE), defined by acid reflux only, is used to identify gastro-esophageal reflux disease (GERD). However, weak acid reflux or non-acid reflux also induces reflux symptoms. Defining abnormal reflux based on all reflux episodes may better identify GERD and would be more useful among patients with atypical GERD symptoms, such as globus. Impedance-pHmetry results of 31 globus patients, off acid suppressants, were analysed. A median of 24 episodes of reflux were observed. Of the reflux episodes, 54% were non-acid reflux and 50% reached the proximal extent. PAE was observed in 6 patients (19%). For 5 patients (16%) without PAE, there was evidence of increased bolus exposure compared to normal controls (an intraesophageal bolus exposure for more than 1.4% of the recording time, defined as pathological bolus exposure, PBE). When GERD was defined by PAE or esophagitis, the prevalence of GERD was 29%. When GERD was defined by PBE, PAE or esophagitis, the prevalence was 42%. PBE identified 13% of the patients who otherwise would have been missed. A significant proportion of patients without PAE had evidence of PBE. PBE may be a more useful definition for identifying patients with abnormal increase in reflux in patients with globus. Further studies are warranted.

  5. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    International Nuclear Information System (INIS)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun; Klempner, Samuel J.; Daroui, Parima

    2016-01-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  6. Radiation dermatitis caused by a bolus effect from an abdominal compression device

    Energy Technology Data Exchange (ETDEWEB)

    Connor, Michael; Wei, Randy L.; Yu, Suhong; Sehgal, Varun [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States); Klempner, Samuel J. [Department of Medicine, Division of Hematology/Oncology, University of California, Orange, CA (United States); Daroui, Parima, E-mail: pdaroui@uci.edu [Department of Radiation Oncology, University of California, Irvine Medical Center, Orange, CA (United States)

    2016-10-01

    American Association of Physicists in Medicine (AAPM) Task Group 176 evaluated the dosimetric effects caused by couch tops and immobilization devices. The report analyzed the extensive physics-based literature on couch tops, stereotactic body radiation therapy (SBRT) frames, and body immobilization bags, while noting the scarcity of clinical reports of skin toxicity because of external devices. Here, we present a clinical case report of grade 1 abdominal skin toxicity owing to an abdominal compression device. We discuss the dosimetric implications of the utilized treatment plan as well as post hoc alternative plans and quantify differences in attenuation and skin dose/build-up between the device, a lower-density alternative device, and an open field. The description of the case includes a 66-year-old male with HER2 amplified poorly differentiated distal esophageal adenocarcinoma treated with neoadjuvant chemo-radiation and the use of an abdominal compression device. Radiation was delivered using volumetric modulated arc therapy (VMAT) with 2 arcs using abdominal compression and image guidance. The total dose was 50.4 Gy delivered over 40 elapsed days. With 2 fractions remaining, the patient developed dermatitis in the area of the compression device. The original treatment plan did not include a contour of the device. Alternative post hoc treatment plans were generated, one to contour the device and a second with anterior avoidance. In conclusion, replanning with the device contoured revealed the bolus effect. The skin dose increased from 27 to 36 Gy. planned target volume (PTV) coverage at 45 Gy was reduced to 76.5% from 95.8%. The second VMAT treatment plan with an anterior avoidance sector and more oblique beam angles maintained PTV coverage and spared the anterior wall, however at the expense of substantially increased dose to lung. This case report provides an important reminder of the bolus effect from external devices such as abdominal compression. Special

  7. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  8. Therapeutic hip injections: Is the injection volume important?

    International Nuclear Information System (INIS)

    Young, R.; Harding, J.; Kingsly, A.; Bradley, M.

    2012-01-01

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  9. Therapeutic hip injections: Is the injection volume important?

    Energy Technology Data Exchange (ETDEWEB)

    Young, R., E-mail: russell.young@gwh.nhs.uk [Department of Radiology, Great Western Hospital, Swindon (United Kingdom); Harding, J. [Department of Radiology, University Hospital Coventry, Coventry (United Kingdom); Kingsly, A. [Department of Mathematics and Statistics, Bristol Institue of Technology, University of the West of England, Bristol (United Kingdom); Bradley, M. [Department of Radiology, Southmead Hospital, Bristol (United Kingdom)

    2012-01-15

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  10. Direct bolus imaging of cervical blood vessels by means of MRI

    International Nuclear Information System (INIS)

    Satoh, Toshihiko; Fujioka, Mutsuhisa; Watari, Tsutomu; Nishimura, Gen; Matsumoto, Toshihiko; Washiya, Sumio; Inoue, Kiyoshi; Horita, Masatoshi; Shimizu, Kohji.

    1991-01-01

    Direct bolus imaging (DBI) is one of the non-invasive method for flow measurements which is based on the bolus tracking technique. DBI permits the direct visualization of flow velocity profiles and vessel band width. We performed screening for cervical vessel disease in patients with vertigo by means of DBI. MR system used here was 0.5 T superconducting imager-SMT-50A (Shimazu Co. Ltd). Pulse sequence parameters were TR= 60 ms, TE= 50 ms, NEX= 1, acquisition matrix; 128 x 256, slice thickness= 5 mm, with cardiac gating. Pulse sequence employed a slice selective RF pulse at the level of C5 vertebral body to tag a disk of fluid perpendicular to the direction of flow, followed by a gradient reforcussed echo. We evaluated each peak high and band width of the common-carotid arteries and the vertebral arteries. Seventy nine of 83 cases had optimal examinations. Abnormal findings of DBI were seen in 15 of 79 cases, (including 2 of subclavian steal syndrome, 1 of carotid obstruction, 5 of vertebral obstruction, 1 of basilar artery obstruction, and 6 of hypoplasia of vertebral artery). The abnormal findings of DBI were well correlated with those of angiographic examinations. We concluded that DBI was suitable to the screening for cervical vessel diseases in patients with vertigo, and should be added to the routine MR studies. (author)

  11. A Factor Increasing Venous Contamination on Bolus Chase Three-dimensional Magnetic Resonance Imaging: Charcot Neuroarthropathy.

    Science.gov (United States)

    Çildağ, Mehmet B; Ertuğrul, Mustafa B; Köseoğlu, Ömer Fk; Armstrong, David G

    2018-01-01

    The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN). Bolus-chase three-dimensional magnetic resonance (MR) of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A), patients with diabetic foot ulcers (Group B) and patients with CN accompanying diabetic foot ulcers (Group C). Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Venous contamination following bolus chase MR was higher in patients with CN.

  12. Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia.

    Science.gov (United States)

    Zizer, Eugen; Seufferlein, Thomas; Hänle, Mark Martin

    2017-02-01

    Introduction and aims  High-resolution esophageal manometry (HRM) has improved the diagnostic work-up of esophageal motility disorders. Simultaneous evaluation of bolus clearance delivers useful information about the function of tubular esophagus. We assessed bolus clearance in a combined HRM-impedance examination for esophagogastric junction outflow obstruction (EGJOO) in comparison to achalasia patients. The collected data were assessed in a retrospective analysis. Patients and methods  After gastroscopy excluded a mechanical esophageal or gastric obstruction, 142 consecutive patients underwent combined HRM-impedance examination. The assessment and interpretation of the manometry results were done according to the Chicago Classification of esophageal motility disorders v3.0. After classifying the motility disorder, the evaluation of bolus clearance was done according to published studies. Results  All patients with achalasia (n = 24) showed a significantly impaired bolus clearance (achalasia cases. This might be helpful as an additional tool to differentiate between achalasia and EGJOO patients. Furthermore, the role of the combined impedance-HRM investigation for early diagnosis of achalasia in "pre-achalasia" condition or in evaluation of potential progress of EGJOO to achalasia should be evaluated in a prospective study. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  14. In Silico Assessment of Literature Insulin Bolus Calculation Methods Accounting for Glucose Rate of Change.

    Science.gov (United States)

    Cappon, Giacomo; Marturano, Francesca; Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni

    2018-05-01

    The standard formula (SF) used in bolus calculators (BCs) determines meal insulin bolus using "static" measurement of blood glucose concentration (BG) obtained by self-monitoring of blood glucose (SMBG) fingerprick device. Some methods have been proposed to improve efficacy of SF using "dynamic" information provided by continuous glucose monitoring (CGM), and, in particular, glucose rate of change (ROC). This article compares, in silico and in an ideal framework limiting the exposition to possibly confounding factors (such as CGM noise), the performance of three popular techniques devised for such a scope, that is, the methods of Buckingham et al (BU), Scheiner (SC), and Pettus and Edelman (PE). Using the UVa/Padova Type 1 diabetes simulator we generated data of 100 virtual subjects in noise-free, single-meal scenarios having different preprandial BG and ROC values. Meal insulin bolus was computed using SF, BU, SC, and PE. Performance was assessed with the blood glucose risk index (BGRI) on the 9 hours after meal. On average, BU, SC, and PE improve BGRI compared to SF. When BG is rapidly decreasing, PE obtains the best performance. In the other ROC scenarios, none of the considered methods prevails in all the preprandial BG conditions tested. Our study showed that, at least in the considered ideal framework, none of the methods to correct SF according to ROC is globally better than the others. Critical analysis of the results also suggests that further investigations are needed to develop more effective formulas to account for ROC information in BCs.

  15. SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

    International Nuclear Information System (INIS)

    Carver, R; Popple, R; Benhabib, S; Antolak, J; Sprunger, C; Hogstrom, K

    2014-01-01

    Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10 9 ), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT

  16. SU-E-T-356: Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Carver, R [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Popple, R; Benhabib, S [UniversityAlabama Birmingham, Birmingham, AL (United Kingdom); Antolak, J [Mayo Clinic, Rochester, MN (United States); Sprunger, C [Louisiana State University, Baton Rouge, LA (United States); Hogstrom, K [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Louisiana State University, Baton Rouge, LA (United States)

    2014-06-01

    Purpose: To evaluate the accuracy of electron dose distribution calculated by the Varian Eclipse electron Monte Carlo (eMC) algorithm for use with recent commercially available bolus electron conformal therapy (ECT). Methods: eMC-calculated electron dose distributions for bolus ECT have been compared to those previously measured for cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV CT anatomy for each site. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The bolus ECT treatment plans were imported into the Eclipse treatment planning system and calculated using the maximum allowable histories (2×10{sup 9}), resulting in a statistical error of <0.2%. Smoothing was not used for these calculations. Differences between eMC-calculated and measured dose distributions were evaluated in terms of absolute dose difference as well as distance to agreement (DTA). Results: Results from the eMC for the retromolar trigone phantom showed 89% (41/46) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of −0.12% with a standard deviation of 2.56%. Results for the nose phantom showed 95% (54/57) of dose points within 3% dose difference or 3 mm DTA. There was an average dose difference of 1.12% with a standard deviation of 3.03%. Dose calculation times for the retromolar trigone and nose treatment plans were 15 min and 22 min, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a Varian Eclipse framework agent server (FAS). Results of this study were consistent with those previously reported for accuracy of the eMC electron dose algorithm and for the .decimal, Inc. pencil beam redefinition algorithm used to plan the bolus. Conclusion: These results show that the accuracy of the Eclipse eMC algorithm is suitable for clinical implementation of bolus ECT.

  17. Prolonged infusion versus intermittent boluses of β-lactam antibiotics for treatment of acute infections: a meta-analysis.

    Science.gov (United States)

    Teo, Jocelyn; Liew, Yixin; Lee, Winnie; Kwa, Andrea Lay-Hoon

    2014-05-01

    The clinical advantages of prolonged (extended/continuous) infusion remain controversial. Previous studies and reviews have failed to show consistent clinical benefits of extending the infusion time. This meta-analysis sought to determine whether prolonged β-lactam infusions were associated with a reduction in mortality and improvement in clinical success. A search of PubMed, EMBASE and The Cochrane Library for randomised controlled trials (RCTs) and observational studies comparing prolonged infusion with intermittent bolus administration of the same antibiotic in hospitalised adult patients was conducted. Primary outcomes evaluated were mortality and clinical success. A total of 29 studies with 2206 patients (18 RCTs and 11 observational studies) were included in the meta-analysis. Compared with intermittent boluses, use of prolonged infusion appeared to be associated with a significant reduction in mortality [pooled relative risk (RR) = 0.66, 95% confidence interval (CI) 0.53-0.83] and improvement in clinical success (RR = 1.12, 95% CI 1.03-1.21). Statistically significant benefit was supported by non-randomised studies (mortality, RR = 0.57, 95% CI 0.43-0.76; clinical success, RR = 1.34, 95% CI 1.02-1.76) but not by RCTs (mortality, RR = 0.83, 95% CI 0.57-1.21; clinical success, RR = 1.05, 95% CI 0.99-1.12). The positive results from observational studies, especially in the face of increasing antibiotic resistance, serve to justify the imperative need to conduct a large-scale, well-designed, multicentre RCT involving critically ill patients infected with high minimum inhibitory concentration pathogens to clearly substantiate this benefit. Copyright © 2014 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  18. Evaluation of the ECAT EXACT HR+ 3D PET scanner in 15O-water brain activation studies

    International Nuclear Information System (INIS)

    Moreno-Cantu, J.J.; Thompson, C.J.; Zatorre, R.J.

    1996-01-01

    We evaluated the performance of the ECAT EXACT HR + 3D whole body PET scanner when employed to measure brain function using 15 O-water-bolus activation protocols in single data acquisition sessions. Using vibrotactile and auditory stimuli as independent activation tasks, we studied the scanner's performance under different imaging conditions in four healthy volunteers. Cerebral blood flow images were acquired from each volunteer using 15 O-water-bolus injections of activity varying from 5 to 20mCi. Performance characteristics. The scanner's dead time grew linearly with injected dose from 10% to 25%. Random events varied from 30% to 50% of the detected events. Scattered events were efficiently corrected at all doses. Noise-effective-count curves plateau at about 15mCi. One-session 12-injection bolus PET activation protocol. Using an acquisition protocol that accounts for the scanner's performance and the practical aspects of imaging volunteers and patients in one session, we assessed the correlation between the statistical significance of activation foci and the dose per injection used The one-session protocol employs 12 bolus injections per subject. We present evidence suggesting that 15-20mCi is the optimal dose per injection to be used routinely in one-time scanning sessions

  19. Status Epilepticus due to Intraperitoneal Injection of Vehicle Containing Propylene Glycol in Sprague Dawley Rats

    Directory of Open Access Journals (Sweden)

    Evon S. Ereifej

    2017-01-01

    Full Text Available Published reports of status epilepticus due to intraperitoneal injection containing propylene glycol in rats are sparse. In fact, there are no reports specifying a maximum safe dose of propylene glycol through intraperitoneal administration. We report here a case of unexpected seizures in Sprague Dawley rats after receiving an intraperitoneal injection containing propylene glycol. Nine-week-old, 225–250 gram male rats were reported to experience tremor progressing to seizures within minutes after given injections of resveratrol (30 mg/kg dissolved in a 40 : 60 propylene glycol/corn oil vehicle solution by direct intraperitoneal (IP slow bolus injection or via a preplaced intraperitoneal catheter. The World Health Organization suggests a maximum dose of 25 mg/kg/day of propylene glycol taken orally and no more than 25 mg/dL in blood serum, whereas the animals used in our study got a calculated maximum 0.52 g/kg (25 times lower dose. Blood tests from the seizing rat support a diagnosis of hemolysis and lactic acidosis which may have led to the seizures, all of which appeared to be a consequence of the propylene glycol administration. These findings are consistent with oral and intravenous administration of propylene glycol toxicity as previously reported in other species, including humans. To our knowledge, this report represents the first published case of status epilepticus due to an IP injection containing propylene glycol.

  20. Balancing selected medication costs with total number of daily injections: a preference analysis of GnRH-agonist and antagonist protocols by IVF patients.

    Science.gov (United States)

    Sills, E Scott; Collins, Gary S; Salem, Shala A; Jones, Christopher A; Peck, Alison C; Salem, Rifaat D

    2012-08-30

    During in vitro fertilization (IVF), fertility patients are expected to self-administer many injections as part of this treatment. While newer medications have been developed to substantially reduce the number of these injections, such agents are typically much more expensive. Considering these differences in both cost and number of injections, this study compared patient preferences between GnRH-agonist and GnRH-antagonist based protocols in IVF. Data were collected by voluntary, anonymous questionnaire at first consultation appointment. Patient opinion concerning total number of s.c. injections as a function of non-reimbursed patient cost associated with GnRH-agonist [A] and GnRH-antagonist [B] protocols in IVF was studied. Completed questionnaires (n = 71) revealed a mean +/- SD patient age of 34 +/- 4.1 yrs. Most (83.1%) had no prior IVF experience; 2.8% reported another medical condition requiring self-administration of subcutaneous medication(s). When out-of-pocket cost for [A] and [B] were identical, preference for [B] was registered by 50.7% patients. The tendency to favor protocol [B] was weaker among patients with a health occupation. Estimated patient costs for [A] and [B] were $259.82 +/- 11.75 and $654.55 +/- 106.34, respectively (p cost difference increased. This investigation found consistently higher non-reimbursed direct medication costs for GnRH-antagonist IVF vs. GnRH-agonist IVF protocols. A conditional preference to minimize downregulation (using GnRH-antagonist) was noted among some, but not all, IVF patient sub-groups. Compared to IVF patients with a health occupation, the preference for GnRH-antagonist was weaker than for other patients. While reducing total number of injections by using GnRH-antagonist is a desirable goal, it appears this advantage is not perceived equally by all IVF patients and its utility is likely discounted heavily by patients when nonreimbursed medication costs reach a critical level.

  1. Doxorubicin: Comparison between 3-h continuous and bolus intravenous administration paradigms on cardio-renal axis, mitochondrial sphingolipids and pathology

    International Nuclear Information System (INIS)

    Kamendi, Harriet; Zhou, Ying; Crosby, Meredith; Keirstead, Natalie; Snow, Debra; Bentley, Patricia; Patel, Nilaben; Barthlow, Herbert; Luo, Wenli; Dragan, Yvonne; Bialecki, Russell

    2015-01-01

    Doxorubicin (DOX) is a potent and effective broad-spectrum anthracycline antitumor agent, but its clinical usefulness is restricted by cardiotoxicity. This study compared pharmacokinetic, functional, structural and biochemical effects of single dose DOX bolus or 3-h continuous iv infusion (3-h iv) in the Han–Wistar rat to characterize possible treatment-related differences in drug safety over a 72 h observation period. Both DOX dosing paradigms significantly altered blood pressure, core body temperature and QA interval (indirect measure of cardiac contractility); however, there was no recovery observed in the bolus iv treatment group. Following the 3-h iv treatment, blood pressures and QA interval normalized by 36 h then rose above baseline levels over 72 h. Both treatments induced biphasic changes in heart rate with initial increases followed by sustained decreases. Cardiac injury biomarkers in plasma were elevated only in the bolus iv treatment group. Tissue cardiac injury biomarkers, cardiac mitochondrial complexes I, III and V and cardiac mitochondrial sphingolipids were decreased only in the bolus iv treatment group. Results indicate that each DOX dosing paradigm deregulates sinus rhythm. However, slowing the rate of infusion allows for functional compensation of blood pressure and may decrease the likelihood of cardiac myocyte necrosis via a mechanism associated with reduced mitochondrial damage. - Highlights: • Despite damaging cardiomyocytes, continuous iv doxorubicin improves cardiovascular outcomes. • This study supports administration of doxorubicin via slow continuous iv infusion limits acute cardio-toxicity. • This study supports use of metabolomic-derived lipid biomarkers for improved quantification of cardiovascular risk. • This study supports systems-based physiological approach to generate a data that can greatly inform risk assessments.

  2. Doxorubicin: Comparison between 3-h continuous and bolus intravenous administration paradigms on cardio-renal axis, mitochondrial sphingolipids and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Kamendi, Harriet, E-mail: harriet_kamendi@kandih.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Zhou, Ying, E-mail: yingzhou526@gmail.com [Oncology Innovative Medicines and Early Development, AstraZeneca, Waltham, MA 02451 (United States); Crosby, Meredith, E-mail: Meredith.crosby@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Keirstead, Natalie, E-mail: Nkeirstead@alnylam.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Snow, Debra, E-mail: Debra.snow@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Bentley, Patricia, E-mail: patricia.bentley@abbvie.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Patel, Nilaben, E-mail: patelnilaben@yahoo.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Barthlow, Herbert, E-mail: Herbert.barthlow@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Luo, Wenli, E-mail: Wenli.luo@astrazeneca.com [Discovery Sciences, Innovative Medicines, AstraZeneca, Waltham, MA 02451 (United States); Dragan, Yvonne, E-mail: Yvonne.P.Dragan@takeda.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States); Bialecki, Russell, E-mail: russell.bialecki@astrazeneca.com [Drug Safety and Metabolism, AstraZeneca, Waltham, MA 02451 (United States)

    2015-12-15

    Doxorubicin (DOX) is a potent and effective broad-spectrum anthracycline antitumor agent, but its clinical usefulness is restricted by cardiotoxicity. This study compared pharmacokinetic, functional, structural and biochemical effects of single dose DOX bolus or 3-h continuous iv infusion (3-h iv) in the Han–Wistar rat to characterize possible treatment-related differences in drug safety over a 72 h observation period. Both DOX dosing paradigms significantly altered blood pressure, core body temperature and QA interval (indirect measure of cardiac contractility); however, there was no recovery observed in the bolus iv treatment group. Following the 3-h iv treatment, blood pressures and QA interval normalized by 36 h then rose above baseline levels over 72 h. Both treatments induced biphasic changes in heart rate with initial increases followed by sustained decreases. Cardiac injury biomarkers in plasma were elevated only in the bolus iv treatment group. Tissue cardiac injury biomarkers, cardiac mitochondrial complexes I, III and V and cardiac mitochondrial sphingolipids were decreased only in the bolus iv treatment group. Results indicate that each DOX dosing paradigm deregulates sinus rhythm. However, slowing the rate of infusion allows for functional compensation of blood pressure and may decrease the likelihood of cardiac myocyte necrosis via a mechanism associated with reduced mitochondrial damage. - Highlights: • Despite damaging cardiomyocytes, continuous iv doxorubicin improves cardiovascular outcomes. • This study supports administration of doxorubicin via slow continuous iv infusion limits acute cardio-toxicity. • This study supports use of metabolomic-derived lipid biomarkers for improved quantification of cardiovascular risk. • This study supports systems-based physiological approach to generate a data that can greatly inform risk assessments.

  3. A factor increasing venous contamination on bolus chase three-dimensional magnetic resonance imaging: Charcot neuroarthropathy

    Directory of Open Access Journals (Sweden)

    Mehmet B Cildag

    2018-01-01

    Full Text Available Background: The study aimed to evaluate the ratio of venous contamination in diabetic cases without foot lesion, with foot lesion and with Charcot neuroarthropathy (CN. Materials and Methods: Bolus-chase three-dimensional magnetic resonance (MR of 396 extremities of patients with diabetes mellitus was analyzed, retrospectively. Extremities were divided into three groups as follows: diabetic patients without foot ulcer or Charcot arthropathy (Group A, patients with diabetic foot ulcers (Group B and patients with CN accompanying diabetic foot ulcers (Group C. Furthermore, amount of venous contamination classified as no venous contamination, mild venous contamination, and severe venous contamination. The relationship between venous contamination and extremity groups was investigated. Results: Severe venous contamination was seen in Group A, Group B, and Group C, 5.6%, 15.2%, and 34.1%, respectively. Statistically significant difference was seen between groups with regard to venous contamination. Conclusion: Venous contamination following bolus chase MR was higher in patients with CN.

  4. Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation.

    Science.gov (United States)

    Godfrey, Devon J; Patel, Bhavik N; Adamson, Justus D; Subashi, Ergys; Salama, Joseph K; Palta, Manisha

    Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans. Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase. GTVs were contoured on each phase by a gastrointestinal-specialized radiation oncologist and reviewed by a fellowship-trained abdominal radiologist who specializes in pancreatic imaging. The volumes of the registered GTVs, their overlap ratio, and the 3-dimensional margin expansions necessary for each GTV to fully encompass GTVs from the other phases were calculated. The contrast difference between tumor and normal pancreas was measured, and 2 radiation oncologists rank-ordered the phases according to their value for the lesion-contouring task. Tumor-to-pancreas enhancement was on average much larger for the LA and PV than the delayed phase or early arterial phases; the LA and PV phases were also consistently preferred by the radiation oncologists. Enhancement differences among the phases resulted in highly variable GTV volumes with no observed trends. Overlap ratios ranged from 18% to 75% across all 3 phases, improving to 43% to 91% when considering only the preferred LA and PV phases. GTV expansions necessary to encompass all GTVs ranged from 0.3 to 1.8 cm for all 3 phases, improving slightly to 0.1 to 1.4 cm when considering just the LA and PV phases. For pancreas SBRT, we recommend combining the GTVs from a multiphasic CT simulation with bolus-tracking, including

  5. Multi-slice computed tomography urography after diuretic injection in children with urinary tract dilatation

    Energy Technology Data Exchange (ETDEWEB)

    Kosucu, P.; Ahmetoglu, A.; Imamoglu, M.; Cay, A.; Ozdemir, O.; Dinc, H.; Kosucu, M.; Sari, A.; Saruhan, H.; Gumele, H.R. [Farabi Hospital, Trabzon (Turkey). Dept. of Radiology

    2004-02-01

    To evaluate the potential use of multi-slice computed tomography urography (MSCTU) after diuretic injection in children with urinary tract dilatation. MSCTU was performed in 19 patients (11 boys, 8 girls, mean age 5.4 years) with suspicion of urinary tract obstruction and dilatation. Furosemide, 1 mg/kg, was injected 3 min before contrast material administration and followed by a bolus of 30 ml of physiologic saline solution immediately after application of contrast material. Excretory-phase images were obtained through the abdomen and pelvis beginning 10 min after initiation of the injection of contrast material. Maximum intensity projection (MIP) and volume rendering (VR) images were post-processed to obtain urographic views. MSCTU revealed pathology in 16 of 19 patients, while 3 patients had normal findings. Ureteropelvic obstruction was found in 4 patients, obstructive megaureter in 8. Both ureteropelvic obstruction and obstructive megaureter were disclosed in 1 patient, partial ureteral duplication in 1 patient, and both complete ureteral duplication and ureterocele in 2 patients. In all patients, MIP and VR images could satisfactorily show the pathologies of the urinary tract. The estimated effective average doses of MSCTU were higher than IVU. Preliminary results of furosemide-enhanced MSCTU demonstrated consistently dilated urinary tracts, obstruction levels, and underlying pathologies better than US and IVU.

  6. Regional cerebral blood flow measurement with intravenous [15O]water bolus and [18F]fluoromethane inhalation

    International Nuclear Information System (INIS)

    Herholz, K.; Pietrzyk, U.; Wienhard, K.; Hebold, I.; Pawlik, G.; Wagner, R.; Holthoff, V.; Klinkhammer, P.; Heiss, W.D.

    1989-01-01

    In 20 patients with ischemic cerebrovascular disease, classic migraine, or angiomas, we compared paired dynamic positron emission tomographic measurements of regional cerebral blood flow using both [ 15 O]water and [ 18 F]fluoromethane as tracers. Cerebral blood flow was also determined according to the autoradiographic technique with a bolus injection of [ 15 O]water. There were reasonable overall correlations between dynamic [ 15 O]water and [ 18 F]fluoromethane values for cerebral blood flow (r = 0.82) and between dynamic and autoradiographic [ 15 O]water values for cerebral blood flow (r = 0.83). We found a close correspondence between abnormal pathologic findings and visually evaluated cerebral blood flow tomograms obtained with the two tracers. On average, dynamic [ 15 O]water cerebral blood flow was 6% lower than that measured with [ 18 F]fluoromethane. There also was a general trend toward a greater underestimation with [ 15 O]water in high-flow areas, particularly in hyperemic areas, probably due to incomplete first-pass extraction of [ 15 O]water. Underestimation was not detected in low-flow areas or in the cerebellum. Absolute cerebral blood flow values were less closely correlated between tracers and techniques than cerebral blood flow patterns. The variability of the relation between absolute flow values was probably caused by confounding effects of the variation in the circulatory delay time. The autoradiographic technique was most sensitive to this type error

  7. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  8. SU-E-T-522: Investigation of Underdosage of Total Body Irradiation with Bilateral Irradiation Scheme

    International Nuclear Information System (INIS)

    Lin, T; Eldib, A; Hossain, M; Price, R; Ma, C

    2015-01-01

    Purpose: Patient in-vivo measurements report lower readings than those predicted from TMR-based treatment planning on TBI patient knees and ankles where rice was placed to fill the gap between patient’s legs. This study is to understand and correct the under dosage of Total Body Irradiation(TBI) with rice tissue equivalent bolus placement at TBI treatment patient setup. Methods: Bilateral TBI scheme was investigated with rice bags bolus placing between patient’s two legs acting as missing tissue. In-house TMR based treatment planning system was commissioned with measurements under TBI condition at 10MV, i.e. source-to-reference distance 383.4cm with 40×40cm field size with 1cm thickness Lucite. Predictions of patient specific dose points are reported at different sites with 200cGy prescription at patient umbilicus point. Solid water and rice bag phantoms are used at TBI conditions for the attenuation factor verification and CT scanned to verify the CT number and electron density. Results: We found that the rice bag bolus overall density is 11% lower than the water; however, the attenuation factor of rice bags could become 15% lower than that of water at TBI condition. This overestimate of rice bag electron density could cause the lack of lateral scatter and the lack of backscatter. This could Result in an overestimate of dose at in-vivo dosimeter measurement points with TMR-based treatment planning systems. Observations of patient specific optically stimulated luminescent dosimeters(OSLDs) were used to confirm this overestimation. Measurements of setups with increasing the rice bag filled patient leg separation were performed to demonstrate eliminating the overdose issue. Conclusion: Rice bolus has a lower electron density than water does(11%) but results in 15% lower in attenuation factor at TBI condition. This effect was observed in patient delivery with OSLD measurements and can be corrected by increasing the filling rice bolus thickness with 15% longer of

  9. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  10. Ocular dynamics of Garcinia cola (Heckel on healthy volunteers following bolus ingestion

    Directory of Open Access Journals (Sweden)

    S. A. Igwe

    2007-12-01

    Full Text Available Garcinia cola Heckel, an angiospermae belonging to the  family Guttiferae, is known in commerce as bitter cola. It is a plant found in the West African subregion, mostly in moist conditions, and often in association with Cola acuminata. The seeds are highly valued ingredients in African ethonomedicine. The seeds have several social uses and applications in folk medicine. These seeds are ordinarily chewed by the local people without prescription or restriction. In an in vivo case control study, the effects of Garcinia cola on some visual functions: pupil diameter, near point of convergence (NPC, amplitude of accommodation (AA, intraocular pressure (IOP, visual acuity (VA and habitual phoria; following bolus ingestion of 20 g was undertaken using healthy visually active volunteers. Results showed that bolus ingestion of Garcinia cola constricted the pupil by 68%, reduced the NPC by 28%, increased the AA by 17.8% at peak effect and decreased the intraocular pressure by 31% without affecting the distance and near VA. The lateral phoria at far and near tended towards esophoria. Possibly the miotic effect and reduction in IOP could be of benefit to patients with raised IOP where conventional drugs may not be effective. Also it is possible that the effects on phoria could be exploited in oculomotor function in combination with visual training.

  11. Intramuscular injection of malignant hyperthermia trigger agents induces hypermetabolism in susceptible and nonsusceptible individuals.

    Science.gov (United States)

    Metterlein, Thomas; Schuster, Frank; Kranke, Peter; Roewer, Norbert; Anetseder, Martin

    2010-01-01

    A new minimally invasive metabolic test for the diagnosis of susceptibility for malignant hyperthermia measuring intramuscular p(CO(2)) and lactate following local application of caffeine and halothane in humans was recently proposed. The present study tested the hypothesis that a more simplified test protocol allows a differentiation between malignant hyperthermia susceptible (MHS) and malignant hyperthermia nonsusceptible (MHN) and control individuals. With approval of the local ethics committee and informed consent, microdialysis and p(CO(2)) probes with attached microtubing were placed into the lateral vastus muscle of six MHS, seven MHN and seven control individuals. Following equilibration, boluses of 500 microl caffeine 80 mmol l(-1) and halothane 10 vol% dissolved in soybean oil were injected locally. p(CO(2)) and lactate were measured spectrophotometrically. The maximal rate of p(CO(2)) increase was significantly higher in MHS than in MHN and control individuals following application of halothane and caffeine, respectively. Intramuscular caffeine injection leads to a significantly higher increase of local lactate levels in MHS than in MHN and control individuals, whereas halothane increased local lactate levels in all investigated groups. Haemodynamic and systemic metabolic parameters did not differ between the investigated groups. Local caffeine and halothane injection increased intramuscular metabolism in MHS individuals significantly more than in the two other groups. In contrast to previous investigations, direct injection of the concentrations of halothane described here increased lactate and p(CO(2)) even in MHN skeletal muscle.

  12. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  13. Myocardial oxygen extraction fraction measured using bolus inhalation of 15O-oxygen gas and dynamic PET

    NARCIS (Netherlands)

    Lubberink, Mark; Wong, YY; Raijmakers, P. G.; Huisman, Marc C.; Schuit, Robert C.; Luurtsema, Geert; Boellaard, Ronald; Knaapen, P; Vonk-Noordegraaf, Anton; Lammertsma, Adriaan A.

    Abstract The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of 15O2. The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue

  14. Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography

    International Nuclear Information System (INIS)

    Seifarth, Harald; Puesken, Michael; Wienbeck, Susanne; Wessling, Johannes; Maintz, David; Heindel, Walter; Juergens, Kai-Uwe; Kalafut, John F.

    2009-01-01

    The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9(±49.9)-396.1(±52.1) HU vs. 366.0(±64.3)-341.6(±72.5) HU; LAD: 398.9(±48.6)-364.6(±44.6) HU vs. 356.3(±69.5)-323.0(±67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(±52.1) vs. 370.7(±70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters. (orig.)

  15. Balancing selected medication costs with total number of daily injections: a preference analysis of GnRH-agonist and antagonist protocols by IVF patients

    Directory of Open Access Journals (Sweden)

    Sills E

    2012-08-01

    Full Text Available Abstract Background During in vitro fertilization (IVF, fertility patients are expected to self-administer many injections as part of this treatment. While newer medications have been developed to substantially reduce the number of these injections, such agents are typically much more expensive. Considering these differences in both cost and number of injections, this study compared patient preferences between GnRH-agonist and GnRH-antagonist based protocols in IVF. Methods Data were collected by voluntary, anonymous questionnaire at first consultation appointment. Patient opinion concerning total number of s.c. injections as a function of non-reimbursed patient cost associated with GnRH-agonist [A] and GnRH-antagonist [B] protocols in IVF was studied. Results Completed questionnaires (n = 71 revealed a mean +/− SD patient age of 34 +/− 4.1 yrs. Most (83.1% had no prior IVF experience; 2.8% reported another medical condition requiring self-administration of subcutaneous medication(s. When out-of-pocket cost for [A] and [B] were identical, preference for [B] was registered by 50.7% patients. The tendency to favor protocol [B] was weaker among patients with a health occupation. Estimated patient costs for [A] and [B] were $259.82 +/− 11.75 and $654.55 +/− 106.34, respectively (p  Conclusions This investigation found consistently higher non-reimbursed direct medication costs for GnRH-antagonist IVF vs. GnRH-agonist IVF protocols. A conditional preference to minimize downregulation (using GnRH-antagonist was noted among some, but not all, IVF patient sub-groups. Compared to IVF patients with a health occupation, the preference for GnRH-antagonist was weaker than for other patients. While reducing total number of injections by using GnRH-antagonist is a desirable goal, it appears this advantage is not perceived equally by all IVF patients and its utility is likely discounted heavily by patients when nonreimbursed medication costs

  16. Policing behaviors, safe injection self-efficacy, and intervening on injection risks: Moderated mediation results from a randomized trial.

    Science.gov (United States)

    Pitpitan, Eileen V; Patterson, Thomas L; Abramovitz, Daniela; Vera, Alicia; Martinez, Gustavo; Staines, Hugo; Strathdee, Steffanie A

    2016-01-01

    We aim to use conditional or moderated mediation to simultaneously test how and for whom an injection risk intervention was efficacious at reducing receptive needle sharing among female sex workers who inject drugs (FSWs-IDUs) in Mexico. Secondary analysis of data from a randomized trial. A total of 300 FSW-IDUs participated in Mujer Mas Segura in Ciudad Juarez, Mexico, and were randomized to an interactive injection risk intervention or a didactic injection risk intervention. We measured safe injection self-efficacy as the hypothesized mediator and policing behaviors (being arrested and syringe confiscation) as hypothesized moderators. In total, 213 women provided complete data for the current analyses. Conditional (moderated) mediation showed that the intervention affected receptive needle sharing through safe injection self-efficacy among women who experienced syringe confiscation. On average, police syringe confiscation was associated with lower safe injection self-efficacy (p = .04). Among those who experienced syringe confiscation, those who received the interactive (vs. didactic) intervention reported higher self-efficacy, which in turn predicted lower receptive needle sharing (p = .04). Whereas syringe confiscation by the police negatively affected safe injection self-efficacy and ultimately injection risk behavior, our interactive intervention helped to "buffer" this negative impact of police behavior on risky injection practices. The theory-based, active skills building elements included in the interactive condition, which were absent from the didactic condition, helped participants' self-efficacy for safer injection in the face of syringe confiscation. (c) 2015 APA, all rights reserved).

  17. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  18. The measurement of fringing fields in a radio-frequency hyperthermia array with emphasis on bolus size

    NARCIS (Netherlands)

    Wiersma, J.; van Dijk, J. D.; Sijbrands, J.; Schneider, C. J.

    1998-01-01

    The limited aperture size through which the em-field of the applicator is emanated and the constraining of this em-field near the bolus' edge is related to the appearance of superficial 'hot spot' phenomena in radiative hyperthermia. Regarding systems based on the concept of the annular phased array

  19. Optimization of Photospheric Electric Field Estimates for Accurate Retrieval of Total Magnetic Energy Injection

    Science.gov (United States)

    Lumme, E.; Pomoell, J.; Kilpua, E. K. J.

    2017-12-01

    Estimates of the photospheric magnetic, electric, and plasma velocity fields are essential for studying the dynamics of the solar atmosphere, for example through the derivative quantities of Poynting and relative helicity flux and using the fields to obtain the lower boundary condition for data-driven coronal simulations. In this paper we study the performance of a data processing and electric field inversion approach that requires only high-resolution and high-cadence line-of-sight or vector magnetograms, which we obtain from the Helioseismic and Magnetic Imager (HMI) onboard Solar Dynamics Observatory (SDO). The approach does not require any photospheric velocity estimates, and the lacking velocity information is compensated for using ad hoc assumptions. We show that the free parameters of these assumptions can be optimized to reproduce the time evolution of the total magnetic energy injection through the photosphere in NOAA AR 11158, when compared to recent state-of-the-art estimates for this active region. However, we find that the relative magnetic helicity injection is reproduced poorly, reaching at best a modest underestimation. We also discuss the effect of some of the data processing details on the results, including the masking of the noise-dominated pixels and the tracking method of the active region, neither of which has received much attention in the literature so far. In most cases the effect of these details is small, but when the optimization of the free parameters of the ad hoc assumptions is considered, a consistent use of the noise mask is required. The results found in this paper imply that the data processing and electric field inversion approach that uses only the photospheric magnetic field information offers a flexible and straightforward way to obtain photospheric magnetic and electric field estimates suitable for practical applications such as coronal modeling studies.

  20. Dosimetry characterization and clinical application of Exa skin: Bolus of high of high density for use with photons; Caracterizacion dosimetrica y aplicacion clinica de Exaskin: bolus de alta densidad para uso con fotones

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Seidel, M.; Velazquez Miranda, S.

    2013-07-01

    Bolus of high density eXaSkin of density 1.6 g/cm{sub 3} is calculated correctly in the planning systems, is easy to use and generates optimum coupling with the radiation area, at the same time which is easily reproducible in their placement, avoiding the use of electron beams. On the other hand its behavior varies very slightly with the presence of air gaps. (Author)

  1. Extraction of [99mTc]-d,l-HM-PAO across the blood-brain barrier

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Knudsen, K B

    1988-01-01

    The initial extraction (E) across the blood-brain barrier (BBB) of [99mTc]-d,l-HM-PAO after intracarotid injection was measured in 14 Wistar rats and 6 patients using the double indicator, single injection method with Na-24 as the cotracer. In both series, cerebral blood flow (CBF) was measured...... was increased from 20 to 120 microliters, while using a 120 microliters bolus containing 10% albumin resulted in a decrease in E. This suggests that HM-PAO binding to albumin is not totally and rapidly reversible during a single passage through brain capillaries and that binding to blood elements may reduce...... the apparent extraction across brain capillaries. In patients using a bolus of 1 ml saline, E decreased linearly with increasing CBF (r = -0.81, p less than 0.001). For a CBF of 0.59 ml/g/min and an average apparent E of 0.72, an apparent PS product of 0.76 ml/g/min was calculated.(ABSTRACT TRUNCATED AT 250...

  2. Primary break with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Cordelle, F.; Champ, M.; Pochard, R.

    1988-10-01

    The probabilitic safety assessment of a 900 MW plant has displayed the potential importance, with regard to the risk, of intermediate primary breaks with failure of the high pressure safety injection system. The probability of such sequence is about 10 -6 /plant X year. Therefore, it is necessary to establish: - if this sequence can lead to core melt down, - if clad ruptures can occur. This event must be taken into account to determine the repair time of contaminated systems. For these studies, a three inch equivalent diameter break is considerd, as this is the most sensitive in its category with regard to these phenomena. In addition to the above objectives, the purpose of these studies is to evaluate the sensitivity of the results to the following parameters: - the time limit at which the operator starts cooling down the plant via the steam generators. Two calculations have been made with the RELAP code (1 and 2) and two with the CATHARE code (3 and 4) - the pump trip time. Four calculations have been made with the CATHARE code (5, 6, 7 and 8). In the case of failure of only one high pressure safety injection file, 6 calculations have been made with the CATHARE code, concerning the influence of pump trip time (9, 10, 11, 12, 13 and 14)

  3. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  4. Comparison of Intermittent and Bolus Enteral Feeding Methods on Enteral Feeding Intolerance of Patients with Sepsis: A Triple-blind Controlled Trial in Intensive Care Units.

    Science.gov (United States)

    Nasiri, Morteza; Farsi, Zahra; Ahangari, Mojtaba; Dadgari, Fahimeh

    2017-10-01

    BACKGROUND Recent trials have shown controversial results on which enteral feeding methods has a lower risk of enteral feeding intolerance. Therefore, we aimed to compare two methods of bolus and intermittent feeding on enteral feeding intolerance of patients with sepsis. METHODS This triple-blind randomized controlled trial was conducted on 60 patients with sepsis, who were fed through tubes for at least 3 days. The patients were randomly assigned into bolus feeding, intermittent feeding, and control groups. Enteral feeding intolerance of all patients was recorded in 3 consecutive days by a researcher-made checklist including the data on gastric residual volume, vomiting, diarrhea, constipation, and abdominal distension. RESULTS There were no significant differences between the three studied groups in none of the intervention days pertaining to constipation, diarrhea, vomiting, abdominal distention, and gastric residual volume ( p > 0.05). Also, no statistically significant difference was found between all variables in the three studied groups during the 3 days ( p > 0.05). CONCLUSION As enteral feeding intolerance of patients with sepsis was similar in both bolus and intermittent feeding methods, it can be concluded that bolus method can still be used as a standard method to decrease the risk of enteral feeding intolerance if it is used properly.

  5. Perfusion redistribution after a pulmonary-embolism-like event with contrast enhanced EIT.

    Science.gov (United States)

    Nguyen, D T; Bhaskaran, A; Chik, W; Barry, M A; Pouliopoulos, J; Kosobrodov, R; Jin, C; Oh, T I; Thiagalingam, A; McEwan, A L

    2015-06-01

    Recent studies showed that regional pulmonary perfusion can be reliably estimated using electrical impedance tomography (EIT) with the aid of hypertonic saline based contrast enhancement. Building on these successful studies, we studied contrast EIT for pulmonary perfusion defect caused by an artificially induced pulmonary embolism (PE) in a large ovine model (N = 8, 78 ± 7.8 kg). Furthermore, the efficacy of a less invasive contrast bolus of 0.77 ml kg(-1) of NaCl 3% was compared with a more concentrated bolus of 0.13 ml kg(-1) of NaCl 20%. Prior to the injection of each contrast bolus injection, ventilation was turned off to provide a total of 40 to 45 s of apnoea. Each bolus of impedance contrast was injected through a catheter into the right atrium. Pulmonary embolisation was performed by balloon occlusion of part of the right branch of the pulmonary trunk. Four parameters representing the kinetics of the contrast dilution in the lung were evaluated for statistical differences between baseline and PE, including peak value, maximum uptake, maximum washout and area under the curve of the averaged contrast dilution curve in each lung. Furthermore, the right lung to left lung (R2L) ratio of each the aforementioned parameters were assessed. While all of the R2L ratios yielded significantly different means between baseline and PE, it can be concluded that the R2L ratios of area under the curve and peak value of the averaged contrast dilution curve are the most promising and reliable in assessing PE. It was also found that the efficacy of the two types of impedance contrasts were not significantly different in distinguishing PE from baseline in our model.

  6. Effect of Admission Oral Diuretic Dose on Response to Continuous versus Bolus Intravenous Diuretics in Acute Heart Failure: An Analysis from DOSE-AHF

    Science.gov (United States)

    Shah, Ravi V.; McNulty, Steven; O'Connor, Christopher M.; Felker, G. Michael; Braunwald, Eugene; Givertz, Michael M.

    2014-01-01

    Background Results from the Diuretic Optimization Strategies in Acute Heart Failure (DOSE-AHF) study suggest that an initial continuous infusion of loop diuretics is not superior to bolus dosing with regard to clinical endpoints in AHF. We hypothesized that outpatient furosemide dose was associated with congestion and poorer renal function, and explored the hypothesis that a continuous infusion may be more effective in patients on higher outpatient diuretic doses. Methods DOSE-AHF randomized 308 patients within 24 hours of admission to high vs. low initial intravenous diuretic dose given as either a continuous infusion or bolus. We compared baseline characteristics and assessed associations between mode of administration (bolus vs. continuous) and outcomes in patients receiving high-dose (≥120 mg furosemide equivalent, n=177) versus low-dose (diuretics. Results Patients on higher doses of furosemide were less frequently on renin-angiotensin system inhibitors (P=.01), and had worse renal function and more advanced symptoms. There was a significant interaction between outpatient dose and mode of therapy (P=0.01) with respect to net fluid loss at 72 hours after adjusting for creatinine and intensification strategy. Admission diuretic dose was associated with an increased risk of death or rehospitalization at 60 days (adjusted HR=1.08 per 20-mg increment in dose, 95% CI 1.01–1.16, P=.03). Conclusions In acute HF, patients on higher diuretic doses have greater disease severity, and may benefit from an initial bolus strategy. PMID:23194486

  7. Simulated effect of timing and Pt quantity injected on On-line NobleChem application on total fuel liftoff

    International Nuclear Information System (INIS)

    Pop, M.G.; Riddle, J.M.; Lamanna, L.S.; Gregorich, C.; Hoornik, A.

    2015-01-01

    Total liftoff is a measure of fuel performance and a risk indicator for fuel reliability. Fuel operability and license limits are directly related to the expected total lifetime liftoff. AREVA's continued commitment to zero fuel failure is expressed, among other efforts, in the continued development and improvement of its fuel cladding corrosion and crud risk assessment tools. The AREVA models used to assess and predict crud deposition on BWR cores over their lifespan have been refined by the development and incorporation of the PEZOG tool in response to the move in the industry to the On-Line NobleChem TM (OLNC) technology. PEZOG models the platinum-enhanced zirconium oxide growth of fuel cladding when exposed to platinum during operation. Depending on the local chemistry and radiation condition, noble metals act as catalysts for many reactions, including but not limited to hydrogen oxidation and oxygen reduction. OLNC's intention is to catalyze the hydrogen and oxygen recombination reaction for core internals protection. However, research has indicated that noble metals catalyze the oxygen reduction under the chemistry and radiation conditions as experienced in the pores of crud deposits, and hence, can increase the corrosion rate of zirconium alloy cladding. The developed PEZOG module calculates the oxide thickness as a function of platinum injection strategy. The stratified nature of oxide and crud layers formed on fuel cladding surfaces is reflected in the calculations as are the different platinum interaction in each of the layers. This paper presents examples of the evaluation of various aspects of the platinum injection strategies and their influence on the oxide growth enhancement as applied to conditions of a U.S. plant. (authors)

  8. Impact of physical properties of biodiesel on the injection process in a common-rail direct injection system

    International Nuclear Information System (INIS)

    Boudy, Frederic; Seers, Patrice

    2009-01-01

    This paper presents the influence of biodiesel fuel properties on the injection mass flow rate of a diesel common-rail injection system. Simulations are first performed with ISO 4113 diesel fuel on a four-cylinder common-rail system to evaluate a single and triple injection strategies. For each injection strategy, the impact of modifying a single fuel property at a time is evaluated so as to quantify its influence on the injection process. The results show that fuel density is the main property that affects the injection process, such as total mass injected and pressure wave in the common-rail system. The fuel's viscosity and bulk modulus also influence, but to a lessen degree, the mass flow rate of the injector notably during multiple injection strategies as individual properties change the fuel's dampening property and friction coefficient.

  9. Tissue Clearance of {sup 131}I and Total Peripheral Resistance in Myocardial Infarction and Hypertension, and During Angiotensin Infusion

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, F. K.; Bors, K. J.; Long, T. E.; Lestina, J. [University of Southern California School of Medicine, Los Angeles, CA (United States)

    1971-02-15

    Tissue clearance of {sup 131}I from the thigh, cardiac output and peripheral resistance was determined in 25 patients: 13 normotensive with recent myocardial infarction but not in congestive heart failure, 7 with hypertension and 5 normotensive control subjects. The effect of the synthesized pressor agent Angiotensin II on the same three measurements was also studied. The present investigation continues a previous one of ours, where a tracer dose of {sup 131}I was injected into the thigh of patients with recent myocardial infarction without signs of heart failure, and its clearance was found to be longer than that of normal subjects. This was thought to be due to increased peripheral resistance or to reduced perfusion of the capillary bed secondary to lowered cardiac output, With the 25 subjects, injection into the thigh of tracer amounts of radioactive iodine was done by Hypospray, a method with distinct advantages over needle injection. After measuring tissue clearance of the tracer, cardiac output was determined by a method which records the transit of the injected radioactive bolus through the heart. The Angiotensin was administered by intravenous infusion to four of the normotensive and one of the hypertensive patients. Calculations of cardiac output, total peripheral resistance, mean blood pressure and blood volume were made by means of standard formulae. Results of the study confirmed expectations. Those patients with myocardial infarction who had delayed tissue clearance of {sup 131}I also had reduced cardiac output. The patients with hypertension had normal tissue clearance of {sup 131}I and normal cardiac output in the presence of increased peripheral resistance. Equivalent hypertension and increased peripheral resistance induced in normotensive subjects by Angiotensin resulted in lowered cardiac output and delayed tissue clearance of {sup 131}I. An increased sensitivity to Angiotensin was noted in hypertensive patients. The tissue clearance of {sup 131}I

  10. Usefulness of an injectable anaesthetic protocol for semen collection through urethral catheterisation in domestic cats.

    Science.gov (United States)

    Pisu, Maria Carmela; Ponzio, Patrizia; Rovella, Chiara; Baravalle, Michela; Veronesi, Maria Cristina

    2017-10-01

    Objectives Although less often requested in comparison with dogs, the collection of semen in cats can be necessary for artificial insemination, for semen evaluation in tom cats used for breeding and for semen storage. Urethral catheterisation after pharmacological induction with medetomidine has proved to be useful for the collection of semen in domestic cats. However, most of the previously used protocols require the administration of high doses of medetomidine that can increase the risk of side effects, especially on the cardiovascular system. In routine clinical practice, one safe and useful injectable anaesthetic protocol for short-term clinical investigations or surgery in cats involves premedication with low intramuscular doses of dexmedetomidine with methadone, followed by intravenous propofol bolus injection. We aimed to assess the usefulness of this injectable anaesthetic protocol for semen collection, via urethral catheterisation, in domestic cats. Methods The study was performed on 38 purebred, adult cats, during the breeding season, and semen was collected via urethral catheterisation using an injectable anaesthesia protocol with methadone (0.2 mg/kg) and dexmedetomidine (5 µg/kg) premedication, followed by induction with propofol. Results The anaesthetic protocol used in the present study allowed the collection of large-volume semen samples, characterised by good parameters and without side effects. Conclusions and relevance The results from the present study suggest that the injectable anaesthetic protocol using methadone and dexmedetomidine premedication, followed by induction with propofol, could be suitable and safe for the collection of a good-quality semen sample, via urethral catheterisation, in domestic cats. It can therefore be used as an alternative to previous medetomidine-based sedation protocols.

  11. Thermographic visualization of the superficial vein and extravasation using the temperature gradient produced by the injected materials

    Science.gov (United States)

    Nakamura, Katsumasa; Sasaki, Tomonari; Ohga, Saiji; Yoshitake, Tadamasa; Terashima, Kotaro; Asai, Kaori; Matsumoto, Keiji; Shinoto, Makoto; Shioyama, Yoshiyuki; Nishie, Akihoro; Honda, Hiroshi

    2014-11-01

    There are few effective methods to detect or prevent the extravasation of injected materials such as chemotherapeutic agents and radiographic contrast materials. To investigate whether a thermographic camera could visualize the superficial vein and extravasation using the temperature gradient produced by the injected materials, an infrared thermographic camera with a high resolution of 0.04 °C was used. At the room temperature of 26 °C, thermal images and the time course of the temperature changes of a paraffin phantom embedded with rubber tubes (diameter 3.2 mm, wall thickness 0.8 mm) were evaluated after the tubes were filled with water at 15 °C or 25 °C. The rubber tubes were embedded at depths of 0 mm, 1.5 mm, and 3.0 mm from the surface of the phantom. Temperature changes were visualized in the areas of the phantom where the tubes were embedded. In general, changes were more clearly detected when greater temperature differences between the phantom and the water and shallower tube locations were employed. The temperature changes of the surface of a volunteer's arm were also examined after a bolus injection of physiological saline into the dorsal hand vein or the subcutaneous space. The injection of 5 ml room-temperature (26 °C) saline into the dorsal hand vein enabled the visualization of the vein. When 3 ml of room-temperature saline was injected through the vein into the subcutaneous space, extravasation was detected without any visualization of the vein. The subtraction image before and after the injection clearly showed the temperature changes induced by the saline. Thermography may thus be useful as a monitoring system to detect extravasation of the injected materials.

  12. Application of direct-injection detector integrated with the multi-pumping flow system to chemiluminescence determination of the total polyphenol index.

    Science.gov (United States)

    Nalewajko-Sieliwoniuk, Edyta; Iwanowicz, Magdalena; Kalinowski, Sławomir; Kojło, Anatol

    2016-03-10

    In this work, we present a novel chemiluminescence (CL) method based on direct-injection detector (DID) integrated with the multi-pumping flow system (MPFS) to chemiluminescence determination of the total polyphenol index. In this flow system, the sample and the reagents are injected directly into the cone-shaped detection cell placed in front of the photomultiplier window. Such construction of the detection chamber allows for fast measurement of the CL signal in stopped-flow conditions immediately after mixing the reagents. The proposed DID-CL-MPFS method is based on the chemiluminescence of nanocolloidal manganese(IV)-hexametaphosphate-ethanol system. The application of ethanol as a sensitizer, eliminated the use of carcinogenic formaldehyde. Under the optimized experimental conditions, the chemiluminescence intensities are proportional to the concentration of gallic acid in the range from 5 to 350 ng mL(-1). The DID-CL-MPFS method offers a number of advantages, including low limit of detection (0.80 ng mL(-1)), high precision (RSD = 3.3%) and high sample throughput (144 samples h(-1)) as well as low consumption of reagents, energy and low waste generation. The proposed method has been successfully applied to determine the total polyphenol index (expressed as gallic acid equivalent) in a variety of plant-derived food samples (wine, tea, coffee, fruit and vegetable juices, herbs, spices). Copyright © 2016 Elsevier B.V. All rights reserved.

  13. The external jugular vein as an injection site in radionuclide angiography

    International Nuclear Information System (INIS)

    Humphrey, S.; Shelton, J.; Wollum, P.; Leguizamon, E.

    1982-01-01

    The first-pass radionuclide angiogram has been shown to be an effective method for evaluation of left ventricular function. When the first-pass technique is used, however, delivery of a compact radionuclide bolus is imperative. The external jugular vein is a safe, effective route of delivery for the bolus; it provides for a high quality, technically accurate test without deleterious effects to the patient

  14. Assessment of complications due to intratympanic injections

    Directory of Open Access Journals (Sweden)

    Yu-Chuan Liu

    2016-03-01

    Full Text Available Objective: The purpose of the study is to report and to analyze the complications following intratympanic injections (ITI of steroids. The occurrence rate of complications at different ITI sites, four quadrants of eardrum, was also compared. Methods: A retrospective clinical review in a medical center. Each patient received ITI twice in a week for 2–3 consecutive weeks as a salvage therapy for sudden sensorineural hearing loss. Post-injection complications, especially transient dizziness and vertigo, were recorded. Patients with acute or chronic vertigo episodes in 1 month were excluded. Results: A total of 59 patients with sudden sensorineural hearing loss and a total of 278 times of ITI were performed in 1 year. The post-injection complications included pain, tongue numbness, transient dizziness, vertigo, tinnitus, and a small persistent perforation. There was no significant difference in the occurrence of these complications between the injections sites on the 4 quadrants of the tympanic membrane. However, there was statistical significance in the post-injection vertiginous episode after IT injections to posterior-inferior quadrant (Q3 and posterior-superior quadrant (Q4 compared to anterior-superior quadrant (Q1 and anterior-inferior quadrant (Q2 (P = 0.0113. Conclusion: IT injection is recommended to be applied to the Q2 since the Q1 and Q4 injections are more likely to induce the adverse effect of tongue numbness, while the Q3 and Q4 areas are more likely to induce post-injection vertigo. Keywords: Intratympanic injection, Sudden deafness, Complications, Vertigo

  15. Optimum bolus wizard settings in insulin pumps in children with Type 1 diabetes

    DEFF Research Database (Denmark)

    Andersen, A J B; Ostenfeld, A; Pipper, C B

    2016-01-01

    : Optimum insulin pump settings at pump initiation depend on both insulin requirements and use of the pump. Settings need to be individualized because the standardized calculation factors are not constant for children. There is a need to develop specific age- and insulin dose-dependent calculation factors.......AIM: To evaluate current insulin pump settings in an optimally regulated paediatric population using bolus wizard. METHODS: We used a retrospective study design to analyse data from 124 children on insulin pump therapy who had optimum HbA1c levels [

  16. SU-E-T-541: Bolus Effect of Thermoplastic Masks in IMRT and VMAT Head and Neck Treatments

    International Nuclear Information System (INIS)

    Zhen, H; Nedzi, L; Chen, S; Jiang, S; Zhao, B

    2014-01-01

    Purpose: To quantitatively evaluate the bolus effect of thermoplalstic mask on patient skin dose during multi-field IMRT and VMAT treatment. Methods: The clinically approved target contours for five head and neck patients were deformably registered to an anthropomorphic Rando phantom. Two plans: Multifield IMRT plan with 7-9 beams and VMAT plan with 2-4 arcs were created for each patient following same dose constraints. 3mm skin was excluded from PTVs but not constrained during optimization. The prescription dose was 200-220 cGy/fraction. A thermoplastic head and shoulder mask was customized for the Rando phantom. Each plan was delivered to the phantom twice with and without mask. During each delivery, two rectangular strips of EBT3 films (1cm x 6.8cm) were placed across the anterior upper and lower neck near PTVs to measure the surface dose. For consistency films were positioned at same locations for same patient. A total of 8 film strips were obtained for each patient. Film dose was calibrated in the range of 0-400cGy on the day of plan delivery. For dose comparison 3 regions of interests (ROIs) of 1×1 cm 2 were selected at left, right and middle part of each film, resulting in 6 point doses at each plan delivery. Results: The films without mask show relatively uniform dose distribution while those with mask clearly show mesh pattern of mask, usually indicating an increase in skin dose. On average the increase in skin dose over all ROIs with mask was 31.9%(±14.8%) with a range of 11.4%- 58.4%. There is no statistically significant difference (p=0.44) between skin dose increase in VMAT (30.8%±15.3%) and IMRT delivery (33.0%±14.9%). Conclusion: Thermoplastic immobilization masks increase surface dose for HN patient by around 30%. The magnitude is comparable between multi-field IMRT and VMAT. Radiochromic EBT3 film serves as an effective tool to quantify bolus effect

  17. Influence of diet or intrarectal bile acid injections on colon epithelial cell proliferation in rats previously injected with 1,2-dimethylhydrazine

    International Nuclear Information System (INIS)

    Glauert, H.P.; Bennink, M.R.

    1983-01-01

    The effects of varying colon bile acid concentrations on rat colon epithelial cell proliferation were studied. Bile acid concentrations were altered by intrarectally injecting either deoxycholic or lithocholic acid for 4 weeks or by increasing the dietary fat or fiber (wheat bran, agar, or carrageenan) intake for 4 weeks. 1,2-Dimethylhydrazine (DMH) was s.c. injected into half of the rats 1 week before treatments began. Colon epithelial cell proliferation was measured by [ 3 H]thymidine autoradiography of colon crypts. Rats injected with DMH had more DNA-synthesizing cells per crypt. Neither bile acid injection nor any of the diets altered the number of DNA-synthesizing cells per crypt. DMH injections, deoxycholic and lithocholic acid intrarectal injections, and dietary agar and wheat bran all increased the total number of cells per crypt. High fat diets and dietary carrageenan did not affect cell number. All diets containing fiber lowered total fecal bile acid concentrations, but increasing the fat content of the diet did not affect them. These results indicate that the bile acid injections and dietary agar and wheat bran induce a slight hyperplasia in the colon

  18. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  19. Unicameral bone cysts treated by injection of bone marrow or methylprednisolone.

    Science.gov (United States)

    Chang, C H; Stanton, R P; Glutting, J

    2002-04-01

    In 79 consecutive patients with unicameral bone cysts we compared the results of aspiration and injection of bone marrow with those of aspiration and injection of steroid. All were treated by the same protocol. The only difference was the substance injected into the cysts. The mean radiological follow-up to detect activity in the cyst was 44 months (12 to 108). Of the 79 patients, 14 received a total of 27 injections of bone marrow and 65 a total of 99 injections of steroid. Repeated injections were required in 57% of patients after bone marrow had been used and in 49% after steroid. No complications were noted in either group. In this series no advantage could be shown for the use of autogenous injection of bone marrow compared with injection of steroid in the management of unicameral bone cysts.

  20. Precision flow-controlled Rb-82 generator for bolus or constant-infusion studies of the heart and brain

    International Nuclear Information System (INIS)

    Yano, Y.; Cahoon, J.L.; Budinger, T.F.

    1981-01-01

    A precision flow-controlled rubidium-82 generator has been constructed to deliver 76-sec Rb-82 at either fast or slow flow rates for bolus or constant-infusion studies. A stepping motor drive is interfaced to a microprocessor for pulsed control of flow rate to deliver the saline eluant solution from a large-volume (150 ml) machined pumping syringe through an alumina column that retains the 25-day Sr-82 parent. The generator system delivers 70-90% of the maximum Rb-82 activity in a 20-25 ml bolus elution of 2% NaCl. The Sr-82/Sr-85 breakthrough is 10 -7 - 10 -6 . Both yield and breakthrough are functions of column length and flow rate. Six separate Sr-82 loadings of the generator were evaluated over a period of nearly 2 yr in studies of myocardial blood perfusion and permeability changes in the blood-brain barrier. Sterility and apyrogenicity of the Rb-82 eluate were maintained during multiple elutions and long-term use of 3-4 mo for each generator loading

  1. Predictors of injection drug use cessation and relapse in a prospective cohort of young injection drug users in San Francisco, CA (UFO Study).

    Science.gov (United States)

    Evans, Jennifer L; Hahn, Judith A; Lum, Paula J; Stein, Ellen S; Page, Kimberly

    2009-05-01

    Studies of injection drug use cessation have largely sampled adults in drug treatment settings. Little is known about injection cessation and relapse among young injection drug users (IDU) in the community. A total of 365 HCV-negative IDU under age 30 years were recruited by street outreach and interviewed quarterly for a prospective cohort between January 2000 and February 2008. Participants were followed for a total of 638 person-years and 1996 visits. We used survival analysis techniques to identify correlates of injection cessation (> or =3 months) and relapse to injection. 67% of subjects were male, median age was 22 years (interquartile range (IQR) 20-26) and median years injecting was 3.6 (IQR 1.3-6.5). 28.8% ceased injecting during the follow-up period. Among those that ceased injecting, nearly one-half resumed drug injection on subsequent visits, one-quarter maintained injecting cessation, and one-quarter were lost to follow-up. Participating in a drug treatment program in the last 3 months and injecting less than 30 times per month were associated with injection cessation. Injecting heroin or heroin mixed with other drugs, injecting the residue from previously used drug preparation equipment, drinking alcohol, and using benzodiazepines were negatively associated with cessation. Younger age was associated with relapse to injection. These results suggest that factors associated with stopping injecting involve multiple areas of intervention, including access to drug treatment and behavioral approaches to reduce injection and sustain cessation. The higher incidence of relapse in the younger subjects in this cohort underscores the need for earlier detection and treatment programs targeted to adolescents and transition-age youth.

  2. Biodistribution of BPA and BSH after single, repeated and simultaneous administrations for neutron-capture therapy of cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, H. [Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, 1-1-3 Minatojima, Chuo-ku, Kobe 650-8586 (Japan)], E-mail: ichikawa@pharm.kobegakuin.ac.jp; Taniguchi, E. [Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, 1-1-3 Minatojima, Chuo-ku, Kobe 650-8586 (Japan); Fujimoto, T. [Department of Orthopaedic Surgery, Hyogo Cancer Center, Akashi 673-0021 (Japan); Fukumori, Y. [Faculty of Pharmaceutical Sciences and Cooperative Research Center of Life Sciences, Kobe Gakuin University, 1-1-3 Minatojima, Chuo-ku, Kobe 650-8586 (Japan)

    2009-07-15

    The effect of administration mode of L-BPA and BSH on the biodistribution in the melanoma-bearing hamsters was investigated. In single intravenous (i.v.) administration, BSH (100 mg BSH/kg) showed no significant retention of {sup 10}B in all the tissues, including tumors, while long-term retention of {sup 10}B in the tumor, muscle and brain was observed with L-BPA (500 mg BPA/kg). The dose escalation of L-BPA and the simultaneous single administration of L-BPA and BSH were not so effective at increasing boron accumulation in tumor after bolus i.v. injection. The boron concentration in tumor was 41 {mu}g B/g after single bolus i.v. injection even at the dose of 1000 mg BPA/kg. In contrast, two sequential bolus i.v. injections of L-BPA with the dose of 500 mg BPA/kg each was found to be effective at increasing {sup 10}B accumulation in the tumor; the maximum {sup 10}B concentration in the tumor reached 52 {mu}g B/g at 3 h after the second i.v. injection.

  3. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  4. Micropropagation of Gerbera (Gerbera jamesonii Bolus).

    Science.gov (United States)

    Minerva, Ghani; Kumar, Surinder

    2013-01-01

    Gerbera (Gerbera jamesonii Bolus) is one of the most popular ornamental flowers worldwide and used both as cut flower and potted plant. Some of them show excellent agronomic characters such as color, floral diameter, stem length, and vigor, which make this plant of commercial importance. Conventionally, multiplication is done through seeds or rhizome cuttings. Rapid multiplication of elite cultivars of Gerbera, with improved agronomic traits, has been achieved by using both direct and indirect tissue culture methods. Direct shoot regeneration was accomplished from stem apices on MS medium supplemented with 1 mg/L 6-benzyladenine (BA) and 1 mg/L kinetin. Indirect shoot induction succeeded from callus differentiation has been achieved on MS medium containing 2 mg/L 2,4-dichlorophenoxyacetic acid, 0.5 mg/L indole-3-acetic acid, and 2 mg/L BA. The in vitro shoots, 4-5 cm long, were rooted by quick dipping the shoot bases for 3-5 s in 2,000 mg/L indole-3-butyric acid solution followed by transfer to the pots containing farmyard manure, soil, and sand (1:1:1 by volume). Initially, in vitro plantlets were covered with glass jars to maintain a high relative humidity (85-90%). As soon as new shoot growth begins, relative humidity is decreased by exposing them to the open environmental conditions prior transferring to the glasshouse. Indirect shoot regeneration increased the frequency of somaclonal variations. The selected somaclones were used in developing new and novel cultivars.

  5. Effects on infarct size and left ventricular function of early intravenous injection of anistreplase in acute myocardial infarction. The APSIM Study Investigators.

    Science.gov (United States)

    Bassand, J P; Bernard, Y; Lusson, J R; Machecourt, J; Cassagnes, J; Borel, E

    1990-03-01

    A total of 231 patients suffering from a first acute myocardial infarction were randomly allocated within 4 hours following the onset of symptoms either to anistreplase or anisoylated plasminogen streptokinase activator complex (APSAC), 30 U over 5 minutes, or to conventional heparin therapy, 5000 IU in bolus injection. Heparin was reintroduced in both groups 4 h after initial therapy at a dosage of 500 IU/kg per day. A total of 112 patients received anistreplase and 119 received heparin within a mean period of 188 +/- 62 min following the onset of symptoms. Infarct size was estimated from single photon emission computerized tomography and expressed in percentage of the total myocardial volume. The patency rate of the infarct-related artery was 77% in the anistreplase group and 36% in the heparin group (p less than 0.001). Left ventricular ejection fraction determined from contrast angiography was significantly higher in the anistreplase group than in the heparin group (6 absolute percentage point difference). A significant 31% reduction in infarct size was found in the anistreplase group (33% for the anterior wall infarction subgroup [p less than 0.05] and 16% for the inferior wall infarction subgroup, NS). A close inverse relation was found between the values of left ventricular ejection fraction and infarct size (r = -.73, p less than 0.01). In conclusion, early infusion of anistreplase in acute myocardial infarction produced a high early patency rate, a significant limitation of infarct size, and a significant preservation of left ventricular systolic function, mainly in the anterior wall infarctions.

  6. Skal vi fortsat anvende etomidat til septiske patienter

    DEFF Research Database (Denmark)

    Toft, Palle; Jensen, Anders Gadegaard

    2011-01-01

    Due to a low cardiovascular complication rate even in patients with shock, etomidate is often used for intubation. Etomidate inhibits the steroid synthesis. A single bolus injection of etomidate has so far been considered to be safe. However, new investigations have shown that even a single bolus...

  7. Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.

    Science.gov (United States)

    Skornitzke, Stephan; Fritz, Franziska; Mayer, Philipp; Koell, Marco; Hansen, Jens; Pahn, Gregor; Hackert, Thilo; Kauczor, Hans-Ulrich; Stiller, Wolfram

    2018-05-01

    Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion. Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kV p with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kV p image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time. Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min -1 , respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (r max = 0.89; p alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.

  8. Relationship between low tube voltage (70 kV and the iodine delivery rate (IDR in CT angiography: An experimental in-vivo study.

    Directory of Open Access Journals (Sweden)

    Michael M Lell

    Full Text Available Very short acquisition times and the use of low-kV protocols in CTA demand modifications in the contrast media (CM injection regimen. The aim of this study was to optimize the use of CM delivery parameters in thoraco-abdominal CTA in a porcine model.Six pigs (55-68 kg were examined with a dynamic CTA protocol (454 mm scan length, 2.5 s temporal resolution, 70 s total acquisition time. Four CM injection protocols were applied in a randomized order. 120 kV CTA protocol: (A 300 mg iodine/kg bodyweight (bw, IDR = 1.5 g/s (flow = 5 mL/s, injection time (ti 12 s (60 kg bw. 70 kV CTA protocols: 150 mg iodine/kg bw: (B IDR = 0.75 g/s (flow = 2.5 mL/s, ti = 12 s (60 kg bw; (C IDR = 1.5 g/s (flow = 5 mL/s, ti = 12 s (60 kg bw; (D IDR = 3.0 g/s (flow = 10 mL/s, ti = 3 s (60 kg bw. The complete CM bolus shape was monitored by creating time attenuation curves (TAC in different vascular territories. Based on the TAC, the time to peak (TTP and the peak enhancement were determined. The diagnostic window (relative enhancement > 300 HU, was calculated and compared to visual inspection of the corresponding CTA data sets.The average relative arterial peak enhancements after baseline correction were 358.6 HU (A, 356.6 HU (B, 464.0 HU (C, and 477.6 HU (D. The TTP decreased with increasing IDR and decreasing ti, protocols A and B did not differ significantly (systemic arteries, p = 0.843; pulmonary arteries, p = 0.183. The delay time for bolus tracking (trigger level 100 HU; target enhancement 300 HU for single-phase CTA was comparable for protocol A and B (3.9, 4.3 s and C and D (2.4, 2.0 s. The scan window time frame was comparable for the different protocols by visual inspection of the different CTA data sets and by analyzing the TAC.All protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to

  9. ANALGESIC EFFECT OF INTRATHECAL BACLOFEN BOLUS ON NEUROPATHIC PAIN IN SPINAL CORD INJURY PATIENTS.

    Science.gov (United States)

    Kumru, Hatice; Benito-Penalva, Jesus; Kofler, Markus; Vidal, Joan

    2018-05-18

    GABA-ergic neurons are widely distributed throughout the central nervous system, including the spinal cord which is important for the transmission of pain impulses to the brain. Here we hypothesized that intrathecal baclofen (ITB) which is a GABA analogue might exert analgesic effects on neuropathic pain, which could be related to subtypes of pain in spinal cord injury (SCI). SCI patients with a cervical or thoracic lesion and neuropathic pain were randomized to receive either a single ITB bolus or placebo. Numerical Rating Scale (NRS), Neuropathic Pain Symptom Inventory (NPSI), and Brief Pain Inventory (BPI) were obtained for assessment of neuropathic pain. Spasticity was assessed using Modified Ashworth Scale and visual analogue scale. Evaluations were performed at baseline, and 4, 8, and 24 hours after application of ITB or placebo. Eight patients received ITB, 5 placebo. Neuropathic pain improved significantly in the ITB group based on NRS, BPI, and NPSI, which revealed an effect on all subtypes of pain. Spasticity declined significantly. In the placebo group, there was neither significant change in pain nor in spasticity. An ITB bolus exerted a significant analgesic effect on all subtypes of neuropathic pain in SCI patients. ITB has analgesic effects on all subtypes of neuropathic pain and can improve interference of neuropathic pain with activities of daily living. ITB might be a promising analgesic treatment to control neuropathic pain. Copyright © 2018. Published by Elsevier Inc.

  10. Insights gained from relating cumulative seismic moments to fluid injection activities

    Science.gov (United States)

    McGarr, A.; Barbour, A. J.

    2017-12-01

    The three earthquakes with magnitudes of 5 or greater that were induced in Oklahoma during 2016 motivated efforts to improve our understanding of how fluid injection operations are related to earthquake activity. In this study, we have addressed the question of whether the volume of fluid injected down wells within 10 km of the mainshock of an induced earthquake sequence can account for its total moment release. Specifically, is the total moment release equal to, or less than, twice the product of the shear modulus and the total volume injected (McGarr, JGR, 2014, equation 7)? In contrast to McGarr's (2014, equation 13) relationship for the maximum moment, M0(max), the relationship for the total moment release has the advantage of being independent of the magnitude distribution. We find that the three sequences in Oklahoma in 2016, M5.1 Fairview, M5.8 Pawnee, M5.0 Cushing, and the 2011 M5.7 Prague sequence all adhere to this relationship. We also found that eight additional sequences of earthquakes induced by various fluid injection activities, widely distributed worldwide, show the same relationship between total moment-release and injected volume. Thus, for injected volumes ranging from 103 up to 107 cubic m, the moment release of an induced earthquake sequence appears to be similarly limited. These results imply that M0(max) for a sequence induced by fluid injection could be as high as twice the product of the shear modulus and the injected volume if the mainshock in the sequence accounts for nearly all of the total moment, as was the case for the 2016 Pawnee M5.8 mainshock. This new upper bound for maximum moment is twice what was proposed by McGarr (2014, equation 13). Our new results also support the assumption in our analysis that the induced earthquake rupture is localized to the seismogenic region that is weakened owing to a pore pressure increase of the order of a seismic stress drop.

  11. Effect of intravenous drug administration mode on drug distribution in a tumor slab: a finite Fourier transform analysis.

    Science.gov (United States)

    Subramaniam, B; Claudius, J S

    1990-03-08

    Cancer therapy using chemotherapeutic drugs frequently involves injection of the drug into the body through some intravenous mode of administration, viz, continuous (drip) infusion or single/multiple bolus injection(s). An understanding of the effect of the various modes of administration upon tumor penetration of drug is essential to rational design of drug therapy. This paper investigates drug penetration into a model tumor of slab geometry (between two capillaries) in which the overall transport rate of drug is limited by intra-tumor transport characterized by an effective diffusion coefficient. Employing the method of Finite Fourier Transforms (FFT), analytical solutions have been obtained for transient drug distribution in both the plasma and the tumor following three modes of administration, viz, continuous infusion, single bolus injection and equally-spaced equal-dose multiple bolus injections, of a given amount of drug. The qualitative trends exhibited by the plasma drug distribution profiles are consistent with reported experimental studies. Two concepts, viz, the dimensionless decay constant and the plasma/tumor drug concentration trajectories, are found to be particularly useful in the rational design of drug therapy. The dimensionless decay constant provides a measure of the rate of drug decay in the plasma relative to the rate of drug diffusion into the tumor and is thus characteristic of the tumor/drug system. The magnitude of this parameter dictates the choice of drug administration mode for minimizing drug decay in the plasma while simultaneously maximizing drug transport into the tumor. The concentration trajectories provide a measure of the plasma drug concentration relative to the tumor drug concentration at various times following injection. When the tumor drug concentration exceeds the plasma drug concentration, the drug will begin to diffuse out of the tumor. Knowledge of the time at which this diffusion reversal occurs is especially useful

  12. Injection related anxiety in insulin-treated diabetes.

    Science.gov (United States)

    Zambanini, A; Newson, R B; Maisey, M; Feher, M D

    1999-12-01

    The presence of injection related anxiety and phobia may influence compliance, glycaemic control and quality of life in patients with insulin-treated diabetes. Unselected consecutive, insulin-treated patients attending a diabetes clinic for follow-up, completed a standardised questionnaire providing an injection anxiety score (IAS) and general anxiety score (GAS). A total of 115 insulin-treated (80 Type 1 and 35 Type 2) diabetic patients completed the questionnaire. Injections had been avoided secondary to anxiety in 14% of cases and 42% expressed concern at having to inject more frequently. An IAS > or = 3 was seen in 28% of patients and of these, 66% injected insulin one to two times/day, 45% had avoided injections, and 70% would be bothered by more frequent injections. A significant correlation between IAS and GAS was seen (Kendall's tau-a 0.30, 95% CI 0.19-0.41, P < 0.001). GAS was significantly associated with both previous injection avoidance and expressed concern at increased injection frequency. No significant correlation was seen with HbA1c and injection or general anxiety scores. Symptoms relating to insulin injection anxiety and phobia have a high prevalence in an unselected group of diabetic patients requiring insulin injections and are associated with higher levels of general anxiety.

  13. Delayed flumazenil injection after endoscopic sedation increases patient satisfaction compared with immediate flumazenil injection.

    Science.gov (United States)

    Chung, Hyun Jung; Bang, Byoung Wook; Kim, Hyung Gil; Kwon, Kye Sook; Shin, Yong Woon; Jeong, Seok; Lee, Don Haeng; Park, Shin Goo

    2014-01-01

    Flumazenil was administered after the completion of endoscopy under sedation to reduce recovery time and increase patient safety. We evaluated patient satisfaction after endoscopy under sedation according to the timing of a postprocedural flumazenil injection. In total, 200 subjects undergoing concurrent colonoscopy and upper endoscopy while sedated with midazolam and meperidine were enrolled in our investigation. We randomly administered 0.3 mg of flumazenil either immediately or 15 minutes after the endoscopic procedure. A postprocedural questionnaire and next day telephone interview were conducted to assess patient satisfaction. Flumazenil injection timing did not affect the time spent in the recovery room when comparing the two groups of patients. However, the subjects in the 15 minutes injection group were more satisfied with undergoing endoscopy under sedation than the patients in the immediate injection group according to the postprocedural survey (p=0.019). However, no difference in overall satisfaction, memory, or willingness to undergo a future endoscopy was observed between the two groups when the telephone survey was conducted on the following day. This study demonstrated that a delayed flumazenil injection after endoscopic sedation increased patient satisfaction without prolonging recovery time, even though the benefit of the delayed flumazenil injection did not persist into the following day.

  14. Myocardial capillary permeability for small hydrophilic indicators during normal physiological conditions and after ischemia and reperfusion

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup

    1991-01-01

    Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation of the inje......Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation...... including microvascular alterations. In open chest dogs transitory increases in capillary extraction fraction and PdS for small hydrophilic solutes were seen following 20 minutes of regional myocardial ischemia and reperfusion. This response could be inhibited by treatment directed against superoxide...

  15. Relationship between esophageal contraction patterns and clearance of swallowed liquid and solid boluses in healthy controls and patients with dysphagia

    NARCIS (Netherlands)

    Bogte, A.; Bredenoord, A. J.; Oors, J.; Siersema, P. D.; Smout, A. J. P. M.

    2012-01-01

    Background Non-obstructive dysphagia patients prove to be a difficult category for clinical management. Esophageal high-resolution manometry (HRM) is a novel method, used to analyze dysphagia. However, it is not yet clear how findings on HRM relate to bolus transport through the esophagus. Methods

  16. Evaluation of total renal function from 99mTc-MAG3 scintigraphy in children

    International Nuclear Information System (INIS)

    Andersson, L.G.; Bratteby, L.E.; Takalo, R.; Svensson, L.

    2002-01-01

    Aim: The aim of the present study was to evaluate the usefulness of dynamic scintigraphy in the assessment of total renal function in children. The Patlak slope of 99m Tc-MAG3 renography curves were compared to the plasma clearance values of 51Cr-EDTA. Material and methods: The study sample consisted of 53 boys and 33 girls with various nephrologic disorders, referred for routine clinical reasons. The median age of the subjects was 5.1 years (range 0.3 - 14.1 years). Imaging procedure. In supine position, the patient received a bolus injection of 1 MBq/kg, (minimum 10 MBq) 99m Tc-MAG3 and a posterior dynamic gamma camera registration was performed for 21 min using 1 frame per second during the first minute and thereafter 10 seconds frames. Data analysis. Time-activity curves were generated from manually drawn heart and renal regions of interest. The MAG3 uptake was calculated from the Patlak-Rutland plot of each kidney by linear curve fitting until the beginning of the excretory phase. A sum of the slope values was used as a measure of total renal MAG3 uptake. Cr-EDTA clearance. Glomerular filtration rate (GFR) was measured from the plasma clearance of 51 Cr-EDTA using single injection, multiple-sample technique. After intravenous injection of 51 Cr-EDTA (74 kBq/kg for children up to 7 years, 37 kBq/kg for children older than 7 years), blood samples were drawn at 5, 10, 15, 45, 60, 120 and 180 min for radioactivity measurement. The GFR was calculated according to Broechner-Mortensen and expressed in ml/min. Results: The absolute 51 Cr-EDTA clearance varied from 9 to 143 ml/min. There was a close linear relationship between 51 Cr-EDTA clearance and MAG3 uptake (Fig). The correlation coefficient was 0.90 and the regression equation (y=43.5 x + 664). Conclusions: In the present study, there was a good correlation between plasma clearance of 51 Cr-EDTA and the sum of the Patlak slopes. The regression equation can be utilised to transform the 99m Tc-MAG3 uptake to an

  17. Associations between bolus infusion of hydrocortisone, glycemic variability and insulin infusion rate variability in critically Ill patients under moderate glycemic control

    NARCIS (Netherlands)

    van Hooijdonk, Roosmarijn T. M.; Binnekade, Jan M.; Bos, Lieuwe D. J.; Horn, Janneke; Juffermans, Nicole P.; Abu-Hanna, Ameen; Schultz, Marcus J.

    2015-01-01

    We retrospectively studied associations between bolus infusion of hydrocortisone and variability of the blood glucose level and changes in insulin rates in intensive care unit (ICU) patients. 'Glycemic variability' and 'insulin infusion rate variability' were calculated from and expressed as the

  18. Changes in basal rates and bolus calculator settings in insulin pumps during pregnancy in women with type 1 diabetes

    DEFF Research Database (Denmark)

    Mathiesen, Jonathan M; Secher, Anna L; Ringholm, Lene

    2014-01-01

    OBJECTIVE: To explore insulin pump settings in a cohort of pregnant women with type 1 diabetes on insulin pump therapy with a bolus calculator. METHODS: Twenty-seven women with type 1 diabetes on insulin pump therapy were included in this study. At 8, 12, 21, 27 and 33 weeks, insulin pump setting...

  19. Biomass fueled closed cycle gas turbine with water injection

    Energy Technology Data Exchange (ETDEWEB)

    Bardi, Silvia [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2001-01-01

    Direct water injection has been studied for a small scale ({approx} 8 MW fuel input) closed cycle gas turbine coupled to a biomass fueled CFB furnace. Two different working fluids have been considered (helium-water mixture and nitrogen-water mixture). The water injection could take place between the compressor stages, as an intercooler, or after the high pressure compressor, as an aftercooler. Both this options have been studied, varying the relative humidity levels after the injection and the temperatures of the injected water. The effect of water injection on thermodynamic properties of the working fluids has been studied, together with its effect on turbomachinery isentropic efficiency. A sensitivity analysis on turbomachinery efficiency and cycle base pressure has been included. The results from this study have been compared to the performance of a dry closed cycle without water injection. The wet cycle shows an electric efficiency in the range 29-32% with helium-water mixture as working fluid and 30-32% with nitrogen-water mixture as working fluid, while the total efficiency (referring to the fuel LHV) is always higher than 100%. In the non-injected cycle the electric efficiency is 30-35% with helium and 32-36 with nitrogen. The total efficiency in the dry case with two level intercooling and postcooling is 87-89%, while is higher than 100% when only one stage inter- and postcooling is present. Aside from this, the study also includes a sizing of the heat exchangers for the different cycle variations. The heat transfer area is very sensible to the working fluid and to the amount of injected water and it's always higher when a nitrogen-water mixture is used. Compared to the cycle without water injection, by the way, the number of heat exchangers is reduced. This will lead to a lower pressure drop and a simpler plant layout. The total heat transfer area, however, is higher in the wet cycle than in the dry cycle.

  20. Detection of Total Phenol in Green and Black Teas by Flow Injection System and Unmodified Screen Printed Electrode

    Directory of Open Access Journals (Sweden)

    Ivanildo Luiz de Mattos

    2010-01-01

    Full Text Available A flow injection system using an unmodified gold screen-printed electrode was employed for total phenol determination in black and green teas. In order to avoid passivation of the electrode surface due to the redox reaction, preoxidation of the sample was realized by hexacyanoferrate(III followed by addition of an EDTA solution. The complex formed in the presence of EDTA minimizes or avoids polymerization of the oxidized phenols. The previously filtered tea sample and hexacyanoferrate(III reagent were introduced simultaneously into two-carrier streams producing two reproducible zones. At confluence point, the pre-oxidation of the phenolic compounds occurs while this zone flows through the coiled reactor and receives the EDTA solution before phenol detection. The consumption of ferricyanide was monitorized at 360 mV versus Ag/AgCl and reflected the total amount of phenolic compounds present in the sample. Results were reported as gallic acid equivalents (GAEs. The proposed system is robust, versatile, environmentally-friendly (since the reactive is used only in the presence of the sample, and allows the analysis of about 35–40 samples per hour with detection limit = 1 mg/L without the necessity for surface cleaning after each measurement. Precise results are in agreement with those obtained by the Folin-Ciocalteu method.

  1. 21 CFR 522.2470 - Tiletamine hydrochloride and zolazepam hydrochloride for injection.

    Science.gov (United States)

    2010-04-01

    ... hydrochloride for injection. 522.2470 Section 522.2470 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT... injection. (a) Specifications. Tiletamine hydrochloride and zolazepam hydrochloride for injection when... pound of body weight. The maximum total safe dose is 13.6 milligrams per pound of body weight. (ii) In...

  2. Achalasia: Dilation, Injection or Surgery?

    OpenAIRE

    Peracchia, Alberto; Bonavina, Luigi

    2000-01-01

    Achalasia results from irreversible alterations of the esophageal myenteric plexus. The target of treatment in this setting is to reduce lower esophageal sphincter resistance to passage of the bolus. Definitive treatment of the disease requires pneumatic dilation or Heller myotomy. Although no controlled studies comparing modern endoscopic and surgical techniques are available, laparoscopic surgery is emerging as the initial intervention of choice.

  3. Systematic assessment of microneedle injection into the mouse cornea.

    Science.gov (United States)

    Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S

    2012-06-20

    Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

  4. Efficacy, distribution and faecal excretion of copper oxide wire particles in a novel bolus in red deer (Cervus elaphus).

    Science.gov (United States)

    Castillo-Alcala, F; Wilson, P R; Molenaar, R; Lopez-Villalobos, N

    2007-04-01

    To determine the efficacy of a novel copper oxide wire particle (COWP) formulation in elevating concentrations of copper (Cu) in the liver and serum of red deer (Cervus elaphus), and to investigate the distribution of particles in the gastrointestinal tract and the rate of their excretion in faeces. Mixed-age red deer hinds were allocated to three groups (n=10 per group) on the basis of pre-treatment liver Cu concentrations. Groups 1 and 2 were treated orally with a 10-g COWP bolus on Days 0 and 30, respectively, while the remaining group served as an untreated control. Animals were slaughtered on Day 60, when blood and liver samples were collected for determination of Cu concentrations. An additional group of 18-month-old red deer hinds (n=20) were treated orally with a 10-g COWP bolus, and four were slaughtered on each of Days 1, 5, 15, 30 and 60 after treatment. The gastrointestinal tract was secured between compartments below the oesophagus and contents rinsed until sedimentation of particles was complete. The sediment was oven-dried and COWP were separated and weighed. Faeces were collected continuously from four additional animals held in metabolism cages for 4 days after treatment, sub-sampled daily, and COWP recovered. Mean liver Cu concentrations at slaughter were 80, 597 and 447 micromol/kg for controls and hinds treated 30, and 60 days previously, respectively. Corresponding mean serum Cu concentrations were 7.7, 12.9 and 11.9 micromol/L, respectively. Liver and serum Cu concentrations were higher in both treatment groups than in untreated control animals (p<0.001). COWP were found in all compartments of the gastrointestinal tract measured, for at least 15 days, and in the rumen/reticulum and abomasum for at least 60 days post-administration. The highest rate of recovery overall was from the rumen/reticulum. Mean weight of COWP recovered from faeces was 0.09 g during the first 24 h and 0.94 g over the first 4 days following administration. The COWP bolus

  5. Simultaneous determination of free and total glycerol in biodiesel by capillary electrophoresis using multiple short-end injection.

    Science.gov (United States)

    Spudeit, Daniel Alfonso; Piovezan, Marcel; Dolzan, Maressa D; Vistuba, Jacqueline Pereira; Azevedo, Mônia Stremel; Vitali, Luciano; Leal Oliveira, Marcone Augusto; Oliveira Costa, Ana Carolina; Micke, Gustavo Amadeu

    2013-12-01

    A rapid method for the simultaneous determination of free glycerol (FG) and total glycerol (TG) in biodiesel by CE using a short-end multiple injection (SE/MI) configuration system is described. The sample preparation for FG involves the extraction of glycerol with water and for TG a saponification reaction is carried out followed by extraction as in the case of FG. The glycerol extracted in both cases is submitted to periodate oxidation and the iodate ions formed are measured on a CE-SE/MI system. The relevance of this study lies in the fact that no analytical procedure has been previously reported for the determination of TG (or of FG and TG simultaneously) by CE. The optimum conditions for the saponification/extraction process were 1.25% KOH and 25°C, with a time of only 5 min, and biodiesel mass in the range of 50.0-200.0 mg can be used. Multiple injections were performed hydrodynamically with negative pressure as follows: 50 mbar/3s (FG sample); 50 mbar/6s (electrolyte spacer); 50 mbar/3s (TG sample). The linear range obtained was 1.55-46.5 mg/L with R(2) > 0.99. The LOD and LOQ were 0.16 mg/L and 0.47 mg/L, respectively for TG. The method provides acceptable throughput for application in quality control and monitoring biodiesel synthesis process. In addition, it offers simple sample preparation (saponification process), it can be applied to a variety biodiesel samples (soybean, castor, and waste cooking oils) and it can be used for the determination of two key parameters related to the biodiesel quality with a fast separation (less than 30 s) using an optimized CE-SE/MI system. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Effect of Bolus Viscosity on the Safety and Efficacy of Swallowing and the Kinematics of the Swallow Response in Patients with Oropharyngeal Dysphagia: White Paper by the European Society for Swallowing Disorders (ESSD).

    Science.gov (United States)

    Newman, Roger; Vilardell, Natàlia; Clavé, Pere; Speyer, Renée

    2016-04-01

    Fluid thickening is a well-established management strategy for oropharyngeal dysphagia (OD). However, the effects of thickening agents on the physiology of impaired swallow responses are not fully understood, and there is no agreement on the degree of bolus thickening. To review the literature and to produce a white paper of the European Society for Swallowing Disorders (ESSD) describing the evidence in the literature on the effect that bolus modification has upon the physiology, efficacy and safety of swallowing in adults with OD. A systematic search was performed using the electronic Pubmed and Embase databases. Articles in English available up to July 2015 were considered. The inclusion criteria swallowing studies on adults over 18 years of age; healthy people or patients with oropharyngeal dysphagia; bolus modification; effects of bolus modification on swallow safety (penetration/aspiration) and efficacy; and/or physiology and original articles written in English. The exclusion criteria consisted of oesophageal dysphagia and conference abstracts or presentations. The quality of the selected papers and the level of research evidence were assessed by standard quality assessments. At the end of the selection process, 33 articles were considered. The quality of all included studies was assessed using systematic, reproducible, and quantitative tools (Kmet and NHMRC) concluding that all the selected articles reached a valid level of evidence. The literature search gathered data from various sources, ranging from double-blind randomised control trials to systematic reviews focused on changes occurring in swallowing physiology caused by thickened fluids. Main results suggest that increasing bolus viscosity (a) results in increased safety of swallowing, (b) also results in increased amounts of oral and/or pharyngeal residue which may result in post-swallow airway invasion, (c) impacts the physiology with increased lingual pressure patterns, no major changes in impaired

  7. Maintenance Therapy With Cetuximab Every Second Week in the First-Line Treatment of Metastatic Colorectal Cancer

    DEFF Research Database (Denmark)

    Pfeiffer, Per; Sorbye, Hafdan; Qvortrup, Camilla

    2015-01-01

    Group performance status of 0 to 2. Patients received 8 courses of Nordic FLOX (oxaliplatin 85 mg/m(2) over 1 hour on day 1, and 5-fluorouracil 500 mg/m(2) as a bolus injection, followed 30 minutes later with bolus folinic acid 60 mg/m(2) on days 1 and 2). Cetuximab was administered every 2 weeks...

  8. Thermal hydraulic analysis of aggressive secondary cooldown in a small break loss of coolant accident with a total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, Seok Jung; Lim, Ho Gon; Yang, Joon Eon

    2003-01-01

    To support the development of a Probabilistic Safety Assessment (PSA) model usable in Riskinformed Applications (RIA) for Korea Standard Nuclear power Plants (KSNP), we have performed a thermal hydraulic analysis of Aggressive Secondary Cooldown (ASC) in a 2-inch Small Break Loss Of Coolant Accident (SBLOCA) with a total loss of High Pressure Safety Injection (HPSI). The present study focuses on the estimation of the success criteria of ASC, and the enhanced understanding of the detailed thermal hydraulic behavior and phenomena. The results have shown that the Reactor Coolant System (RCS) pressure can be reduced to the Low Pressure Safety Injection (LPSI) operation conditions without core damage. It was also shown that more relaxed success criteria compared to those in the previous PSA models of KSNP could be used in the new PSA model. However, it was found that the results could be affected by various parameters related with ASC operation, i.e., reference temperature for the calculation of the cooldown rate and its control method

  9. Achalasia: Dilation, Injection or Surgery?

    Directory of Open Access Journals (Sweden)

    Alberto Peracchia

    2000-01-01

    Full Text Available Achalasia results from irreversible alterations of the esophageal myenteric plexus. The target of treatment in this setting is to reduce lower esophageal sphincter resistance to passage of the bolus. Definitive treatment of the disease requires pneumatic dilation or Heller myotomy. Although no controlled studies comparing modern endoscopic and surgical techniques are available, laparoscopic surgery is emerging as the initial intervention of choice.

  10. Cost-effectiveness of once daily GLP-1 receptor agonist lixisenatide compared to bolus insulin both in combination with basal insulin for the treatment of patients with type 2 diabetes in Norway.

    Science.gov (United States)

    Huetson, Pernilla; Palmer, James L; Levorsen, Andrée; Fournier, Marie; Germe, Maeva; McLeod, Euan

    2015-01-01

    Lixisenatide is a potent, selective and short-acting once daily prandial glucagon-like peptide-1 receptor agonist which lowers glycohemoglobin and body weight by clinically significant amounts in patients with type 2 diabetes treated with basal insulin, with limited risk of hypoglycemia. To assess the cost-effectiveness of lixisenatide versus bolus insulin, both in combination with basal insulin, in patients with type 2 diabetes in Norway. The IMS CORE Diabetes Model, a non-product-specific and validated simulation model, was used to make clinical and cost projections. Transition probabilities, risk adjustments and the progression of complication risk factors were derived from the UK Prospective Diabetes Study, supplemented with Norwegian data. Patients were assumed to receive combination treatment with basal insulin, lixisenatide or bolus insulin therapy for 3 years, followed by intensification of a basal-bolus insulin regimen for their remaining lifetime. Simulated healthcare costs, taken from the public payer perspective, were derived from microcosting and diagnosis related groups, discounted at 4% per annum and reported in Norwegian krone (NOK). Productivity costs were also captured based on extractions from the Norwegian Labor and Welfare Administration. Health state utilities were derived from a systematic literature review. Sensitivity and scenario analyses were performed. Lixisenatide in combination with basal insulin was associated with increased quality-adjusted life years (QALYs) and reduced lifetime healthcare costs compared to bolus insulin in combination with basal insulin in patients with Type 2 diabetes, and can be considered dominant. The net monetary benefit of lixisenatide versus bolus insulin was NOK 39,369 per patient. Results were sensitive to discounting, the application of excess body weight associated disutility and uncertainty surrounding the changes in HbA1c. Lixisenatide may be considered an economically efficient therapy in combination

  11. LPS infusion suppresses serum FGF21 levels in healthy adult volunteers

    DEFF Research Database (Denmark)

    Lauritzen, Esben Stistrup; Rittig, Nikolaj; Bach, Ermina

    2017-01-01

    circulating levels of FGF21 after lipopolysaccharide (LPS) infusion. DESIGN: Two randomized, single blinded, placebo-controlled crossover trials were used. SETTING: The studies were performed at a university hospital clinical research center. PATIENTS AND INTERVENTIONS: Study 1 (LPS bolus): Eight young......, healthy, lean males were investigated two times: 1) after isotonic saline injection, and 2) after LPS injection (bolus of 1 ng/kg). Each study day lasted 4 hours. Study 2 (continuous LPS infusion): Eight, healthy males were investigated two times: 1) during continuously isotonic saline infusion, and 2......) during continuously LPS infusion (0.06 ng/kg/h). Each study day lasted 4 hours. Circulating FGF21 levels were quantified every second hour by an immunoassay. RESULTS: A LPS bolus resulted in a late suppression (t = 240 minutes) of serum FGF21 (P=0.035). Continuous LPS infusion revealed no significant...

  12. Radiotherapy in differentiated thyroid cancer: Optimal dose distribution using a wax bolus

    International Nuclear Information System (INIS)

    Mayer, R.; Stucklschweiger, G.; Oechs, A.; Pakish, B.; Hackl, A.; Preidler, K.; Szola, D.

    1994-01-01

    The study includes 53 patients with differentiated thyroid cancer, who underwent surgical and radioiodine therapy as well as hormone therapy. Postoperative radiotherapy was performed in all patients in 'mini-mantle-technique' with parallel opposed fields, followed by an anterior boost-field with electrons up to 60-64 Gy, using a wax bolus for optimal dose distribution in the target volume sparing out the spinal cord as much as possible. The dose to the spinal cord did not exceed 44 Gy in any case. The study shows that radiotherapy with doses up to 60-64 Gy plays an important role in postsurgical therapeutic management. Therefore nonradical surgery is a less important prognostic factor for survival and local recurrence in patients with differentiated thyroid cancer than histological diagnosis in combination with age and lymph node involvement

  13. Promoting Safe Injection Practices : The Challenge Ahead

    Directory of Open Access Journals (Sweden)

    V K Srivastava

    2006-06-01

    Full Text Available Injections are one of the most common health care procedures in the world. Global estimates range between 12 billion-16 billion injections each year’. Most of the injections (90 to 95% are given for therapeutic purposes and only 5 to 10% are given for immunization. It is estimated that worldwide every year a billion injections are given to women and children for immunization. Up to half of these injections are currently thought to be unsafe. Due to the sheer burden of injections and the coresponding magnitude of unsafe injections, the proportion of blood borne pathogen transmission is much larger than is due to unsafe blood transfusion. Unsafe injections are responsible for million cases of Hepatitis B and C and an estimated one-quarter of a million cases of HIV annually. Worldwide 8 to 16 million hepatitis B, 2.3 - 4.7 million hepatitis C and 80,000 - 1,60,000 HIV infections are estimated to occur yearly form reuse of syringes and needles without adequate sterilization2. In the less developed countries, the unsafe injection practices account for an estimated $ 535 million in health care costs and result in nearly 1.3 million deaths a year. In a developing country like India where unnecessary injections are common, the total bur­den of injections is estimated to be 3.7 billion injections per year3. Certain studies that have been carried out in India,along with anecdotal evidence point towards a large numbe- of unnecessary, inappropriate, unsafe injections and inadequate sharps waste management4 5. A high proportion of injections given in India for immunization are unsafe due to reuse of needles/ syringes. The popularity of curative injections remains high due to various factors influencing the behaviour of prescribers / injection givers as well as clients.

  14. Transvenous DSA: ECG-controlled cardial effects and venous complications after pre-atrial injection of nonionic contrast media

    International Nuclear Information System (INIS)

    Arlart, I.P.; Sigel, H.

    1986-01-01

    Transvenous DSA is a diagnostic technique for ambulatory examination that is well tolerated by patients, although it is commonly known that bolus injection of contrast medium for examination of the cardiovascular system may affect the cardiovascular hemodynamic process. The prospective study described was intended to reveal in 100 patients the effects on ECG data, as well as clinical symptoms of non-tolerance of contrast medium (nonionic, with high iodine content, Iopamidol 370), applied by central pre-atrial injection. In addition, catheterization-induced complications in the venous system of the arm were studied in 130 patients. Change of heart rate was the most frequent effect observed (increase in 49% of patients pretreated with Buscopan, decrease in 36% of non-pretreated patients). The second next effects were supraventricular and ventricular ES (20%), minor prolongations of PQ and QRS intervals (14%), and ST lowering (3%), without clinical symptons. In one case, an attack of Angina pectoris was observed, another patient developed a cutane allergy. After catheterization of brachial vein, thromboses were observed in 3% of patients, as well as local inflammations in 6%, short attacks of fever in 2.3%. The complications were observed for the most part in cases where re-sterilised catheters had been used. (orig.) [de

  15. Comparison of bolus and continuous infusion of esmolol on hemodynamic response to laryngoscopy, endotracheal intubation and sternotomy in coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Esra Mercanooglu Efe

    2014-07-01

    Full Text Available BACKGROUND AND OBJECTIVE: The aim of this randomized, prospective and double blinded study is to investigate effects of different esmolol use on hemodynamic response of laryngoscopy, endotracheal intubation and sternotomy in coronary artery bypass graft surgery. METHODS: After approval of local ethics committee and patients' written informed consent, 45 patients were randomized into three groups equally. In Infusion Group; from 10 min before intubation up to 5th minute after sternotomy, 0.5 mg/kg/min esmolol infusion, in Bolus Group; 2 min before intubation and sternotomy 1.5 mg/kg esmolol IV bolus and in Control Group; %0.9 NaCl was administered. All demographic parameters were recorded. Heart rate and blood pressure were recorded before infusion up to anesthesia induction in every minute, during endotracheal intubation, every minute for 10 minutes after endotracheal intubation and before, during and after sternotomy at first and fifth minutes. RESULTS: While area under curve (AUC (SAP × time was being found more in Group B and C than Group I, AUC (SAP × T int and T st and AUC (SAP × T2 was found more in Group B and C than Group I (p < 0.05. Moreover AUC (HR × T st was found less in Group B than Group C but no significant difference was found between Group B and Group I. CONCLUSION: This study highlights that esmolol infusion is more effective than esmolol bolus administration on controlling systolic arterial pressure during endotracheal intubation and sternotomy in CABG surgery.

  16. High power neutral beam injection in LHD

    International Nuclear Information System (INIS)

    Tsumori, K.; Takeiri, Y.; Nagaoka, K.

    2005-01-01

    The results of high power injection with a neutral beam injection (NBI) system for the large helical device (LHD) are reported. The system consists of three beam-lines, and two hydrogen negative ion (H - ion) sources are installed in each beam-line. In order to improve the injection power, the new beam accelerator with multi-slot grounded grid (MSGG) has been developed and applied to one of the beam-lines. Using the accelerator, the maximum powers of 5.7 MW were achieved in 2003 and 2004, and the energy of 189 keV reached at maximum. The power and energy exceeded the design values of the individual beam-line for LHD. The other beam-lines also increased their injection power up to about 4 MW, and the total injection power of 13.1 MW was achieved with three beam-lines in 2003. Although the accelerator had an advantage in high power beam injection, it involved a demerit in the beam focal condition. The disadvantage was resolved by modifying the aperture shapes of the steering grid. (author)

  17. A randomized phase III multicenter trial comparing irinotecan in combination with the Nordic bolus 5-FU and folinic acid schedule or the bolus/infused de Gramont schedule (Lv5FU2) in patients with metastatic colorectal cancer

    DEFF Research Database (Denmark)

    Glimelius, B; Sørbye, H; Balteskard, L

    2008-01-01

    not differ (4% versus 6%, P = 0.3). Grade 3/4 neutropenia (11% versus 5%, P = 0.01) and grade 2 alopecia (18% versus 9%, P = 0.002) were more common in the FLIRI group. The 60-day mortality was 2.4% versus 2.1%. CONCLUSIONS: Irinotecan with the bolus Nordic schedule (FLIRI) is a convenient treatment with PFS...... and OS comparable to irinotecan with the Lv5FU2 schedule. Neutropenia and alopecia are more prevalent, but both regimens are equally well tolerated....

  18. Methods of bolusing the tracheostomy stoma

    International Nuclear Information System (INIS)

    Beitler, Jonathan J.; Yaparpalvi, Ravindra; Biancia, Cesar Della; Fontenla, Doracy P.

    2001-01-01

    Purpose: The tracheostomy stoma is a potential site of recurrence for patients who have subglottic cancer or subglottic spread of cancer. In these patients, it is important that the anterior supraclavicular field does not underdose the posterior wall of the tracheostomy stoma when using a 6-MV anterior photon field. Conventionally, this problem is surmounted with placement of a plastic tracheostomy tube, which is uncomfortable for the patient, potentially traumatic, and can interfere with vocalization via a tracheal esophageal puncture. Our study was designed to investigate the dosimetry of this region and see if alternate methods would be effective. Methods and Materials: A phantom was constructed using a No. 6 tracheostomy tube as the model for the tracheostomy curvature and size. Using the water-equivalent phantom, film dosimetry, and films oriented parallel to the en face field, we investigated the dose at the depth of the surface of the posterior wall of the phantom's tracheostomy stoma. Dose was measured both in space and at the tissue interface by scanning points of interest both horizontally and vertically. We measured doses with a No. 6 and No. 8 plastic tracheostomy tube, either 0.5 cm and 1.0 cm of bolus (1-cm airhole) with no tracheostomy tube, as well as 0.3 cm and 0.6 cm tissue-equivalent Aquaplast (Med-Tec Co., Orange City, Iowa) over the tracheostomy. Dosimetry at the posterior interface was confirmed using thermoluminescent dosimeters. Results: Three mm and 6 mm of Aquaplast produced a posterior tracheal dose of 93% and 100%. Conclusion: There is no need for these patients to wear a temporary plastic tracheostomy tube during their external radiation therapy. Aquaplast should allow better position reproducibility, reduce trauma, not interfere with patient respiratory efforts, and be compatible with vocalization via a tracheal esophageal puncture

  19. The staying safe intervention: training people who inject drugs in strategies to avoid injection-related HCV and HIV infection.

    Science.gov (United States)

    Mateu-Gelabert, Pedro; Gwadz, Marya Viorst; Guarino, Honoria; Sandoval, Milagros; Cleland, Charles M; Jordan, Ashly; Hagan, Holly; Lune, Howard; Friedman, Samuel R

    2014-04-01

    This pilot study explores the feasibility and preliminary efficacy of the Staying Safe Intervention, an innovative, strengths-based program to facilitate prevention of infection with the human immunodeficiency virus and with the hepatitis C virus among people who inject drugs (PWID). The authors explored changes in the intervention's two primary endpoints: (a) frequency and amount of drug intake, and (b) frequency of risky injection practices. We also explored changes in hypothesized mediators of intervention efficacy: planning skills, motivation/self-efficacy to inject safely, skills to avoid PWID-associated stigma, social support, drug-related withdrawal symptoms, and injection network size and risk norms. A 1-week, five-session intervention (10 hours total) was evaluated using a pre- versus 3-month posttest design. Fifty-one participants completed pre- and posttest assessments. Participants reported significant reductions in drug intake and injection-related risk behavior. Participants also reported significant increases in planning skills, motivation/self-efficacy, and stigma management strategies, while reducing their exposure to drug withdrawal episodes and risky injection networks.

  20. Systematic assessment of microneedle injection into the mouse cornea

    Directory of Open Access Journals (Sweden)

    Matthaei Mario

    2012-06-01

    Full Text Available Abstract Background Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Methods Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. Results A mean corneal area of 5.0 ±1.4 mm2 (mean ± SD and 7.7 ±1.4 mm2 was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Conclusions Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively

  1. Improving total knee arthroplasty perioperative pain management using a periarticular injection with bupivacaine liposomal suspension

    Directory of Open Access Journals (Sweden)

    Mark A. Snyder, MD

    2016-03-01

    Full Text Available Patients undergoing total knee arthroplasty (TKA report low satisfaction with postoperative pain control. The purpose of this study is to examine if there is a difference in post-operative pain for TKA patients without femoral nerve block receiving an intra-operative pericapsular injection of bupivacaine liposome suspension (EXPAREL; Pacira Pharmaceuticals, Inc., San Diego, California versus a concentrated multi drug cocktail. Seventy TKA patients were randomly assigned to either the bupivacaine liposome or the multi-drug cocktail. Post-operative pain scores, morphine sulfate equivalence consumption values, adverse events, and overall pain control satisfaction scores were collected. Patients reported significantly higher pain level for the cocktail group on post-op day 1 (p < .05 and post-op day 2 (p < .01 versus the bupivacaine liposome group. This same trend was found for morphine sulfate equivalence consumption in the PACU (p < .01 and post-op day 2 (p < .01. Higher satisfaction in pain control (p < .001 and overall experience (p < .01 was also found in the bupivacaine liposome group. Finally, significantly more adverse events were found in the multi-drug group versus the bupivacaine liposome group (p < .05. The study findings demonstrated a non-inferior difference, albeit not a clinically significant difference, in patient-perceived pain scores, morphine sulfate equivalence consumption, adverse events, and overall satisfaction.

  2. The effects of intratendinous and retrocalcaneal intrabursal injections of corticosteroid on the biomechanical properties of rabbit Achilles tendons.

    Science.gov (United States)

    Hugate, Ronald; Pennypacker, Jason; Saunders, Marnie; Juliano, Paul

    2004-04-01

    The use of corticosteroid injections in the treatment of retrocalcaneal bursitis is controversial. We assessed the effects of corticosteroid injections, both within the tendon substance and into the retrocalcaneal bursa, on the biomechanical properties of rabbit Achilles tendons. The systemic effects of bilateral corticosteroid injections were also studied. The rabbits were divided into three treatment groups. The rabbits in Group I received injections of corticosteroid into the Achilles tendon on the left side and injections of normal saline solution into the Achilles tendon on the right, those in Group II received injections of corticosteroid into the retrocalcaneal bursa on the left side and injections of saline solution into the Achilles tendon on the right, and those in Group III received injections of corticosteroid into the Achilles tendon on the left side and injections of corticosteroid into the retrocalcaneal bursa on the right. These injections were given weekly for three weeks. At four weeks after the final injection, the tendons were harvested and were tested biomechanically to determine failure load, midsubstance strain and total strain, modulus of elasticity, failure stress, and total energy absorbed. The site of failure was also documented. The groups were compared according to the location of the injections, the type of injection (steroid or saline solution), and the total systemic load of steroid. Specimens from limbs that had received intratendinous injections of corticosteroid showed significantly decreased failure stress compared with those from limbs that had received intratendinous injections of saline solution (p = 0.008). Specimens from limbs that had received intrabursal injections of corticosteroid demonstrated significantly decreased failure stress (p = 0.05), significantly decreased total energy absorbed (p = 0.017), and significantly increased total strain (p = 0.049) compared with specimens from limbs that had received intratendinous

  3. A single intracoronary injection of midkine reduces ischemia/reperfusion injury in swine hearts: a novel therapeutic approach for acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Hisaaki eIshiguro

    2011-06-01

    Full Text Available Several growth factors are effective for salvaging myocardium and limiting infarct size in experimental studies with small animals. Their benefit in large animals and feasibility in clinical practice remains to be elucidated. We investigate the cardioprotective effect of midkine (MK in swine subjected to ischemia/reperfusion (I/R. I/R was created in swine by left anterior descending coronary artery occlusion for 45 min using a percutaneous over-the-wire balloon catheter. MK protein was injected as a bolus through the catheter at the initiation of reperfusion (midkine injected group; MKT. Saline was injected in controls (CONT. Survival rate 24h after I/R was significantly higher in MKT than in CONT, whereas infarct size/area at risk was almost 5 times smaller. Echocardiography in MKT revealed a significantly higher percent wall thickening of the interventricular septum, a higher % fractional shortening and a lower E/e’ compared with CONT. LV catheterization in MKT showed a lower LVEDP, and a higher dP/dtmax compared with CONT. TUNEL-positive myocytes and CD45-positive cell infiltration in the peri-infarct area were significantly less in MKT than in CONT. Here, we showed that a single intracoronary injection of MK protein in swine hearts at the onset of reperfusion dramatically reduces infarct size and mortality and ameliorates systolic/diastolic LV function. This beneficial effect is associated with a reduction of apoptotic and inflammatory reactions. MK application during percutaneous coronary intervention may become a promising adjunctive therapy in acute coronary syndromes.

  4. Salvianolate injection in the treatment of unstable angina pectoris

    Science.gov (United States)

    Zhang, Dan; Wu, Jiarui; Liu, Shi; Zhang, Xiaomeng; Zhang, Bing

    2016-01-01

    Abstract Background: To systematically evaluate the clinical efficacy and safety of Salvianolate injection in the treatment of unstable angina pectoris (UAP). Methods: Using literature databases, we conducted a thorough and systematic retrieval of randomized controlled trials (RCTs) that using Salvianolate injection for treating UAP. The Cochrane Risk of Bias Assessment Tool was used to evaluate the methodological quality of the RCTs, and then the data were extracted and meta-analyzed by RevMan5.2 software. Results: A total of 22 RCTs with 2050 participants were included. The meta-analysis indicated that the combined use of Salvianolate injection and western medicine (WM) in the treatment of UAP can achieve a superior effect in angina pectoris total effective rate (risk ratio [RR] = 1.22, 95% confidence interval [CI] (1.17, 1.27), Z = 10.15, P < 0.00001], and the total effectiveness rate of electrocardiogram [RR = 1.26, 95% CI (1.19,1.34), Z = 7.77, P < 0.00001]. In addition, Salvianolate injection can improve the nitroglycerin withdrawal rate and the serum level of NO, decrease high-sensitivity C-reactive protein. Adverse drug reactions (ADRs) or adverse drug events (ADEs) were reported in 6 RCTs involving 15 cases; however, there were no serious ADRs/ADEs. Conclusion: Based on the systematic review, the combined use of Salvianolate injection and WM in the treatment of UAP can achieve a better effect; however, there was no definitive conclusion about its safety. More the large-sample and multicenter RCTs are needed to support its clinical usage. PMID:28002341

  5. [Treatment of autonomous and cystic thyroid nodules with intranodular ethanol injection].

    Science.gov (United States)

    Braga-Basaria, Milena; Trippia, Marcus Adriano; Stolf, Anderson Ravy; Mesa, Cléo; Graf, Hans

    2002-01-01

    Intranodular ethanol injection has been used for the past 10 years as an efficient modality for treating patients with thyroid nodules. Several studies have reported the success of this therapy in autonomous and cystic nodules and, more recently, in cold benign nodules. To evaluate the efficacy of this therapeutic modality on the treatment of autonomous and cystic thyroid nodules. 42 patients (26 with cystic and 16 with autonomous nodules) were treated with ultrasound guided intranodular 99% ethanol injection and followed for 6 months. No major complications were observed during or after treatment, however, most of the patients reported slight to moderate pain and/or discomfort after the injection. Most of the nodules showed reduction after the treatment. Autonomous nodules had a mean reduction of 50.3% and cystic nodules of 69.3%. No significant differences in pretreatment serum total T3, total T4 or TSH were observed among the patients in the cystic group. Patients in the autonomous group with hyperfunctioning nodules showed a decrease in serum total T3, total T4 and an increase in serum TSH levels, hence, proving the effectiveness of this therapy. Intranodular ethanol injection is a safe and efficient treatment for autonomous and cystic nodules of the thyroid.

  6. Myocardial capillary permeability for small hydrophilic indicators during normal physiological conditions and after ischemia and reperfusion

    DEFF Research Database (Denmark)

    Svendsen, J H

    1991-01-01

    Myocardial capillary permeability for small hydrophilic solutes (51Cr-EDTA or 99mTc-DTPA) has been measured using intracoronary indicator bolus injection and external radioactivity registration (the single injection, residue detection method). The method is based on kinetic separation...

  7. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  8. Proton accumulator ring injection studies

    International Nuclear Information System (INIS)

    Cooper, R.K.; Neil, V.K.

    1977-01-01

    Protons may be created in an accelerator or storage ring by stripping electrons from neutral hydrogen atoms that have been injected into the machine. Because Liouville's theorem is violated by this type of injection, particles may be continually injected into a region of phase space that is already populated, and the density in that region increases with time. A computational investigation was made of the evolution of the distribution of particles in longitudinal phase space during such an injection process for a storage ring operating below the transition energy. In one calculation, an rf cavity is present in the ring and particles are injected into the stable phase region once each revolution. The purpose of this calculation is to determine the rf voltage necessary to overcome the longitudinal self-forces and contain the particles within the region of stable phase. In a second calculation, the rf is turned off, so that there is spreading in azimuth of the injected particles (i.e., de-bunching). The de-bunching occurs because of the initial energy spread and the action of the self-forces. One purpose of the calculation is to determine the total energy spread after a given number of revolutions. Another purpose is to elucidate the effect of finite resistance in the vacuum tank walls. For sufficiently high current, the finite resistance can cause bunching of a beam that is initially uniform in azimuth. Therefore it might be expected that the finite resistance would inhibit or prevent de-bunching once the number of particles injected reaches some threshold, and that this threshold would depend upon the energy spread in the beam

  9. Particle balance studies in TEXTOR during experiments of pellet injection, helium injection, and ICR-heating

    International Nuclear Information System (INIS)

    Banno, T.; Finken, K.H.; Gray, D.S.; Winter, J.

    1995-01-01

    Analysis based on the particle conservation law has been carried out to observe the global fuelling process in tokamak discharges. The response of the net recycling flux from the first wall is investigated in the tokamak TEXTOR, using calibrated signals of the gas feed rate, the neutral gas pressure in the vessel, the total amount of electrons, and the particle removal rates by the ALT-II belt-pump limiter and by a main pump unit. Net absorption (pumping) of hydrogen by the wall is observed for almost all tokamak discharges since a new wall conditioning technique called siliconisation is employed. The net absorption or fuelling depending on the discharge condition influenced by injection of pellets, by helium gas injection combined with neutral beam injection, and by rf heating can be interpreted in terms of the particle-induced desorption effect with depth profile taken into consideration. ((orig.))

  10. Injection Drug Use Quality of Life scale (IDUQOL: A validation study

    Directory of Open Access Journals (Sweden)

    Palepu Anita

    2005-07-01

    Full Text Available Abstract Background Existing measures of injection drug users' quality of life have focused primarily on health and health-related factors. Clearly, however, quality of life among injection drug users is impacted by a range of unique cultural, socioeconomic, medical, and geographic factors that must also be considered in any measure. The Injection Drug User Quality of Life (IDUQOL scale was designed to capture the unique and individual circumstances that determine quality of life among injection drug users. The overall purpose of the present study was to examine the validity of inferences made from the IDUQOL by examining the (a dimensionality, (b reliability of scores, (c criterion-related validity evidence, and (d both convergent and discriminant validity evidence. Methods An exploratory factor analysis using principal axis factoring in SPSS 12.0 was conducted to determine whether the use of a total score on the IDUQOL was advisable. Reliability of scores from the IDUQOL was obtained using internal consistency and one-week test-retest reliability estimates. Criterion-related validity evidence was gathered using variables such as stability of housing, sex trade involvement, high-risk injection behaviours, involvement in treatment programs, emergency treatment or overdose over the previous six months, hospitalization and emergency treatment over the subsequent six month period post data collection. Convergent and discriminant validity evidence was gathered using measures of life satisfaction, self-esteem, and social desirability. Results The sample consisted of 241 injection drug users ranging in age from 19 to 61 years. Factor analysis supports the use of a total score. Both internal consistency (alpha = .88 and one-week test-retest reliability (r = .78 for IDUQOL total scores were good. Criterion-related, convergent, and discriminant validity evidence supports the interpretation of IDUQOL total scores as measuring a construct consistent with

  11. Intravenous dexketoprofen induces less injection pain than racemic ketoprofen.

    Science.gov (United States)

    Sjövall, S; Kokki, M; Nokela, A; Halinen, L; Turunen, M; Kokki, H

    2015-08-01

    Ketoprofen has high analgesic efficacy against inflammatory and nociceptive pain. Additionally, when ketoprofen is administered in conjunction with an opioid during pain management, it prevents the development of opioid-induced hyperalgesia. The main limitation for racemic ketoprofen IV administration is venous irritation. Dexketoprofen is the active enantiomer of racemic ketoprofen and has a similar analgesic efficacy in a dose proportion of 1 : 2, but it causes fewer adverse effects than racemic ketoprofen. It has been claimed that dexketoprofen may cause less frequent and less severe injection pain than racemic ketoprofen. In this study, we compared the injection pain of IV administered racemic ketoprofen and dexketoprofen in elective surgical patients. The ethics committee of our institution approved this randomized, double-blinded, two-treatment, two-period, crossover clinical comparison of ketoprofen and dexketoprofen. A total of 221 ASA I-III adult patients, aged 20-75 years, were initially IV administered either 0·5 mg/kg racemic ketoprofen followed 2 h later with 0·25 mg/kg dexketoprofen (group 1) or vice versa (group 2). Both compounds were diluted in 20 mL of normal saline and were injected over 6 min. Patients reported injection pain on an 11-point numerical rating scale (NRS) (0 = no pain, 10 = most pain). Significantly less injection pain was reported after dexketoprofen administration. A total of 201 of 209 patients reported pain during racemic ketoprofen injection, and 157 of 210 patients reported pain during dexketoprofen injection, respectively. Moderate or severe pain was reported by 90 (41%) patients during racemic ketoprofen administration and by 43 (20%) during dexketoprofen injection (P = 0·001). The mean of injection pain during racemic ketoprofen injection was 4·2 (SD 2·5) and was 2·5 (2·4) during dexketoprofen injection (P = 0·001). No serious or unexpected adverse events were reported. Dexketoprofen causes

  12. Comparison of continuous versus intermittent furosemide administration in dogs with acute heart failure

    Directory of Open Access Journals (Sweden)

    Zita Filipejová

    2016-01-01

    Full Text Available Pulmonary oedema is a life-threatening condition which should be treated promptly in the emergency room with oxygen, cage rest, and diuretic therapy. Traditionally, bolus administration of furosemide is the treatment of choice. However, there is emerging information that continuous rate infusion might be more effective than bolus injections in relieving clinical signs and producing a lower rate of complications such as azotaemia, dehydration, and electrolyte imbalances. We tested the effect of furosemide both in bolus (4–6 mg/kg intravenously and continuous rate infusion (1 mg/kg/h in 30 dogs that had been presented with fulminant pulmonary oedema during 2 days of hospitalization. No differences in the selected biochemical indicators between the groups were found. There were significant differences in blood urea nitrogen in the bolus injection group and creatinine and phosphorus in the continuous rate infusion group between days 1 and 2. The results of this study showed no differences in the approach of furosemide administration in the management of pulmonary oedema. Both methods may cause renal and electrolyte complications, however, further studies with a larger number of patients are recommended.

  13. Factors predicting incremental administration of antihypertensive boluses during deep brain stimulator placement for Parkinson's disease.

    Science.gov (United States)

    Rajan, Shobana; Deogaonkar, Milind; Kaw, Roop; Nada, Eman Ms; Hernandez, Adrian V; Ebrahim, Zeyd; Avitsian, Rafi

    2014-10-01

    Hypertension is common in deep brain stimulator (DBS) placement predisposing to intracranial hemorrhage. This retrospective review evaluates factors predicting incremental antihypertensive use intraoperatively. Medical records of Parkinson's disease (PD) patients undergoing DBS procedure between 2008-2011 were reviewed after Institutional Review Board approval. Anesthesia medication, preoperative levodopa dose, age, preoperative use of antihypertensive medications, diabetes mellitus, anxiety, motor part of the Unified Parkinson's Disease Rating Scale score and PD duration were collected. Univariate and multivariate analysis was done between each patient characteristic and the number of antihypertensive boluses. From the 136 patients included 60 were hypertensive, of whom 32 were on angiotensin converting enzyme inhibitors (ACEI) or angiotensin receptor blockers (ARB), told to hold on the morning of surgery. Antihypertensive medications were given to 130 patients intraoperatively. Age (relative risk [RR] 1.01; 95% confidence interval [CI] 1.00-1.02; p=0.005), high Joint National Committee (JNC) class (p10 years (RR 1.2; 95%CI 1.1-1.3; p=0.001) were independent predictors for antihypertensive use. No difference was noted in the mean dose of levodopa (p=0.1) and levodopa equivalent dose (p=0.4) between the low (I/II) and high severity (III/IV) JNC groups. Addition of dexmedetomidine to propofol did not influence antihypertensive boluses required (p=0.38). Intraoperative hypertension during DBS surgery is associated with higher age group, hypertensive, diabetic patients and longer duration of PD. Withholding ACEI or ARB is an independent predictor of hypertension requiring more aggressive therapy. Levodopa withdrawal and choice of anesthetic agent is not associated with higher intraoperative antihypertensive medications. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Ocular silicon distribution and clearance following intravitreal injection of porous silicon microparticles.

    Science.gov (United States)

    Nieto, Alejandra; Hou, Huiyuan; Sailor, Michael J; Freeman, William R; Cheng, Lingyun

    2013-11-01

    Porous silicon (pSi) microparticles have been investigated for intravitreal drug delivery and demonstrated good biocompatibility. With the appropriate surface chemistry, pSi can reside in vitreous for months or longer. However, ocular distribution and clearance pathway of its degradation product, silicic acid, are not well understood. In the current study, rabbit ocular tissue was collected at different time point following fresh pSi (day 1, 5, 9, 16, and 21) or oxidized pSi (day 3, 7, 14, 21, and 35) intravitreal injection. In addition, dual-probe simultaneous microdialysis of aqueous and vitreous humor was performed following a bolus intravitreal injection of 0.25 mL silicic acid (150 μg/mL) and six consecutive microdialysates were collected every 20 min. Silicon was quantified from the samples using inductively coupled plasma-optical emission spectroscopy. The study showed that following the intravitreal injection of oxidized pSi, free silicon was consistently higher in the aqueous than in the retina (8.1 ± 6.5 vs. 3.4 ± 3.9 μg/mL, p = 0.0031). The area under the concentration-time curve (AUC) of the retina was only about 24% that of the aqueous. The mean residence time was 16 days for aqueous, 13 days for vitreous, 6 days for retina, and 18 days for plasma. Similarly, following intravitreal fresh pSi, free silicon was also found higher in aqueous than in retina (7 ± 4.7 vs. 3.4 ± 4.1 μg/mL, p = 0.014). The AUC for the retina was about 50% of the AUC for the aqueous. The microdialysis revealed the terminal half-life of free silicon in the aqueous was 30 min and 92 min in the vitreous; the AUC for aqueous accounted for 38% of the AUC for vitreous. Our studies indicate that aqueous humor is a significant pathway for silicon egress from the eye following intravitreal injection of pSi crystals. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. In vivo measurement of haloperidol affinity to dopamine D2/D3 receptors by [123I]IBZM and single photon emission computed tomography

    DEFF Research Database (Denmark)

    Videbaek, C; Toska, K; Friberg, L

    2001-01-01

    This study examines the feasibility of a steady-state bolus-integration method with the dopamine D2/D3 receptor single photon emission computer tomography (SPECT) tracer, [123I]IBZM, for determination of in vivo affinity of haloperidol. The nonspecific binding of [123I]IBZM was examined in the rat...... brain by infusion of haloperidol to plasma levels approximately 100 times the Kd level in man. In humans, Kd for haloperidol binding was measured in four healthy volunteers that were examined twice: once with partial dopamine D2/D3 receptor blockade obtained by a scheduled infusion of unlabeled...... haloperidol (0.7 mg total dosage), and once in an unblocked state. Blood sampling and SPECT were performed intermittently during 6 hours after intravenous [123I]IBZM bolus injection. Plasma [123I]IBZM was determined by octane extraction. Plasma haloperidol was determined by a radioimmunoassay, and plasma...

  16. Usefulness of the Bolus-Tracking Baseline Scan for the Diagnosis of Hepatic Steatosis in Abdominal Computed Tomography: A Feasibility Study

    International Nuclear Information System (INIS)

    Gossner, J.; Schäfer, S.

    2013-01-01

    Nonalcoholic fatty liver disease (NAFLD) is a common pathology in western societies. Unenhanced computed tomography (CT) of the liver is a valuable tool in determining the presence of steatosis hepatis, but in most departments standard CT protocols of abdomen often do not include unenhanced scans anymore. In a small series of 22 patients the liver density was measured in the acquired low-dose baseline scan for bolus tracking and was compared to the measurement in a regular unenhanced CT scan of the upper abdomen. The mean difference between the unenhanced CT scan and the low-dose baseline scan was 3.4 HU (range 0.2–8.6 HU); the difference between these two scans was 5 HU or smaller in 82% of the patients. There was a significant difference between the two used CT scanners; this has to be kept in mind before implementing this approach into daily practice. All but one patient with fatty liver disease on unenhanced CT were diagnosed using the baseline scan. The baseline scan for bolus tracking may be useful for the diagnosis or in the followup of fatty liver disease

  17. Can repeat injection provide clinical benefit in patients with cervical disc herniation and stenosis when the first epidural injection results only in partial response?

    Science.gov (United States)

    Lee, Jung Hwan; Lee, Sang-Ho

    2016-07-01

    Epidural steroid injection (ESI) is known to be an effective treatment for neck or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after single ESI, there has been little evidence supporting the usefulness of this procedure. The purpose of this study, therefore, was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than intermittent ESI performed only when pain was aggravated. One hundred eighty-four patients who underwent transforaminal ESI (TFESI) for treatment of axial neck and radicular arm pain due to HIVD or SS and could be followed up for 1 year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (numeric rating scale (NRS) ≥ 3 after the first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 76) comprised partial responders who did not receive repeat injection at the prescribed interval, but received intermittent injections only for aggravation of pain. Various clinical data were assessed, including total number of injections during 1 year, NRS duration of Group A, or after first injection in Group B (time to reinjection). Groups A and B were compared in terms of total population, HIVD, and SS. In the whole population, HIVD subgroup, and SS subgroup, patients in Group A required significantly fewer injections to obtain satisfactory pain relief during the 1-year follow-up period. Group A showed a significantly longer time to reinjection and longer NRS Group B did. Repeat TFESI conducted at 2- to 3-week intervals after the first injection in partial responders contributed to greater clinical benefit compared with intermittent TFESI performed only upon pain

  18. Treatment intensification without improved HbA1c levels in children and adolescents with Type 1 diabetes mellitus.

    Science.gov (United States)

    Sildorf, S M; Hertel, N T; Thomsen, J; Fredheim, S; Hastrup, H; Pipper, C; Hertz, B; Svensson, J

    2016-04-01

    To examine trends in diabetes treatment in Danish children and adolescents with Type 1 diabetes mellitus, comparing treatment intensity with metabolic outcomes in the population, and to describe the challenges of population-based registries in a clinical setting with rapidly changing treatment methods. This observational study is based on the Danish national population registry of childhood diabetes, which includes 99% of children diagnosed with Type 1 diabetes before the age of 15 years. We included 4527 people diagnosed between 2000 and 2012. Self-monitored blood glucose measurements, insulin injections/boluses, treatment method and metabolic control quantifications were analysed and adjusted for the effects of gender and ethnicity, the combined effect of age, visit year and duration, and for the random effects of individual and hospital settings. Treatment was intensified via an increasing number of self-monitored blood glucose measurements and injections/boluses. More than six injections/boluses and an increased number of self-monitored blood glucose measurements were significantly associated with lower metabolic control. No reduction, however, in the overall mean HbA1c concentration was observed between 2005 [66 mmol/mol (8.2%)] and 2012 [65 mmol/mol (8.1%)]. Changed registration practices in 2009 introduced artificial jumps in data. Intensifying treatment alone does not lead to improved metabolic control in the overall population despite the appearance of lower HbA1c in individuals with a greater number of self-monitored blood glucose measurements and injections/boluses. The contradictory results reflect difficulties in using observational studies to predict results of intervention in the individual. Data collected from population-based registries need to be adjusted continuously to reflect changes in care. © 2015 Diabetes UK.

  19. Construction and characterization of valve for fast gas injection

    International Nuclear Information System (INIS)

    Ueda, M.; Rossi, J.O.; Aso, Y.; Mangueira, L.S.; Pereira, C.A.

    1989-01-01

    An electromagnetic valve for fast gas injection was built and characterized. This type of gas injection valve has been routinely applied to various plasma experiments: in magnetic confinement devices as TOKAMAK, RFP and Compact Toroids as well as intense ion beam and neutral particle generators. The valve is capable of injecting gas pulses with up to 80 m Torr peak pressure, rising time < 400 μs and duration time of 40 ms, in the present experimental set-up. It is easy to build and its components can be totally acquired in the country. (author)

  20. Comparison of /sup 133/Xe washout curves after bolus inhalation, perfusion, and equilibration

    Energy Technology Data Exchange (ETDEWEB)

    Devos, P; Demedts, M; Vandecruys, A; Cosemans, J; De Roo, M

    1978-01-01

    In 6 healthy subjects and 13 patients with chronic obstructive lung disease, /sup 133/Xe washout curves after bolus inhalation, perfusion and equilibration were compared, using a gamma camera and computerized data handling. In healthy subjects the washout after equilibration was significantly slower than after the two other procedures. As this phenomenon occurred at the basal zones, it was attributed to the presence of airway closure in some units. In patients, the three washouts were significantly different from each other. This indicated the existence of intraregional inhomogeneity in ventilation, perfusion and ventilation-perfusion ratio. Our conclusion is that comparison of these different washout methods yields valuable information not only on absolute values of pulmonary function but also on the intraregional distribution, which cannot be obtained by other examinations.

  1. Unilateral versus bilateral thyroarytenoid Botulinum toxin injections in adductor spasmodic dysphonia: a prospective study

    Science.gov (United States)

    Upile, Tahwinder; Elmiyeh, Behrad; Jerjes, Waseem; Prasad, Vyas; Kafas, Panagiotis; Abiola, Jesuloba; Youl, Bryan; Epstein, Ruth; Hopper, Colin; Sudhoff, Holger; Rubin, John

    2009-01-01

    Objectives In this preliminary prospective study, we compared unilateral and bilateral thyroarytenoid muscle injections of Botulinum toxin (Dysport) in 31 patients with adductor spasmodic dysphonia, who had undergone more than 5 consecutive Dysport injections (either unilateral or bilateral) and had completed 5 concomitant self-rated efficacy and complication scores questionnaires related to the previous injections. We also developed a Neurophysiological Scoring (NPS) system which has utility in the treatment administration. Method and materials Data were gathered prospectively on voice improvement (self-rated 6 point scale), length of response and duration of complications (breathiness, cough, dysphagia and total voice loss). Injections were performed under electromyography (EMG) guidance. NPS scale was used to describe the EMG response. Dose and unilateral/bilateral injections were determined by clinical judgment based on previous response. Time intervals between injections were patient driven. Results Low dose unilateral Dysport injection was associated with no significant difference in the patient's outcome in terms of duration of action, voice score (VS) and complication rate when compared to bilateral injections. Unilateral injections were not associated with any post treatment total voice loss unlike the bilateral injections. Conclusion Unilateral low dose Dysport injections are recommended in the treatment of adductor spasmodic dysphonia. PMID:19852852

  2. Unilateral versus bilateral thyroarytenoid Botulinum toxin injections in adductor spasmodic dysphonia: a prospective study

    Directory of Open Access Journals (Sweden)

    Abiola Jesuloba

    2009-10-01

    Full Text Available Abstract Objectives In this preliminary prospective study, we compared unilateral and bilateral thyroarytenoid muscle injections of Botulinum toxin (Dysport in 31 patients with adductor spasmodic dysphonia, who had undergone more than 5 consecutive Dysport injections (either unilateral or bilateral and had completed 5 concomitant self-rated efficacy and complication scores questionnaires related to the previous injections. We also developed a Neurophysiological Scoring (NPS system which has utility in the treatment administration. Method and materials Data were gathered prospectively on voice improvement (self-rated 6 point scale, length of response and duration of complications (breathiness, cough, dysphagia and total voice loss. Injections were performed under electromyography (EMG guidance. NPS scale was used to describe the EMG response. Dose and unilateral/bilateral injections were determined by clinical judgment based on previous response. Time intervals between injections were patient driven. Results Low dose unilateral Dysport injection was associated with no significant difference in the patient's outcome in terms of duration of action, voice score (VS and complication rate when compared to bilateral injections. Unilateral injections were not associated with any post treatment total voice loss unlike the bilateral injections. Conclusion Unilateral low dose Dysport injections are recommended in the treatment of adductor spasmodic dysphonia.

  3. Organ Distribution of 13N Following Intravenous Injection of [13N]Ammonia into Portacaval-Shunted Rats.

    Science.gov (United States)

    Cruz, Nancy F; Dienel, Gerald A; Patrick, Patricia A; Cooper, Arthur J L

    2017-06-01

    Ammonia is neurotoxic, and chronic hyperammonemia is thought to be a major contributing factor to hepatic encephalopathy in patients with liver disease. Portacaval shunting of rats is used as an animal model to study the detrimental metabolic effects of elevated ammonia levels on body tissues, particularly brain and testes that are deleteriously targeted by high blood ammonia. In normal adult rats, the initial uptake of label (expressed as relative concentration) in these organs was relatively low following a bolus intravenous injection of [ 13 N]ammonia compared with lungs, kidneys, liver, and some other organs. The objective of the present study was to determine the distribution of label following intravenous administration of [ 13 N]ammonia among 14 organs in portacaval-shunted rats at 12 weeks after shunt construction. At an early time point (12 s) following administration of [ 13 N]ammonia the relative concentration of label was highest in lung with lower, but still appreciable relative concentrations in kidney and heart. Clearance of 13 N from blood and kidney tended to be slower in portacaval-shunted rats versus normal rats during the 2-10 min interval after the injection. At later times post injection, brain and testes tended to have higher-than-normal 13 N levels, whereas many other tissues had similar levels in both groups. Thus, reduced removal of ammonia from circulating blood by the liver diverts more ammonia to extrahepatic tissues, including brain and testes, and alters the nitrogen homeostasis in these tissues. These results emphasize the importance of treatment paradigms designed to reduce blood ammonia levels in patients with liver disease.

  4. Effects of switching from prandial premixed insulin therapy to basal plus two times bolus insulin therapy on glycemic control and quality of life in patients with type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Ito H

    2014-04-01

    Full Text Available Hiroyuki Ito, Mariko Abe, Shinichi Antoku, Takashi Omoto, Masahiro Shinozaki, Shinya Nishio, Mizuo Mifune, Michiko ToganeDepartment of Diabetes, Metabolism and Kidney Disease, Edogawa Hospital, Tokyo, JapanBackground: The effects of switching from prandial premixed insulin therapy (PPT injected three times a day to basal plus two times bolus insulin therapy (B2B on glycemic control and quality of life were investigated in patients with type 2 diabetes mellitus.Methods: The clinical course was prospectively observed during the first 16 weeks after switching to B2B (insulin glargine plus insulin glulisine before breakfast and dinner in 27 subjects previously treated with PPT using 50/50 premixed insulin. The Diabetes Treatment Satisfaction Questionnaire (DTSQ was administered at the start and end of the study.Results: The glycated hemoglobin (HbA1c level (8.3%±1.8% to 8.2%±1.1% and the DTSQ score did not change between the start and end of the study. An improvement in HbA1c level was found in nine (33% subjects. The change in HbA1c showed a significant negative correlation with baseline HbA1c, and was significantly better in patients with a baseline HbA1c >8.0% than in those with an HbA1c ≤8.0% (−0.9±2.0 versus 0.3±0.6, respectively, P=0.02. The change in DTSQ score representing treatment satisfaction was significantly greater in patients whose HbA1c level was improved than in those in whom it was not (2.7±3.6 versus −0.8±3.5, P=0.04.Conclusion: B2B was noninferior to PPT with regard to HbA1c levels in patients with type 2 diabetes mellitus. B2B should be considered particularly for subjects whose glycemic control is poor despite PPT.Keywords: type 2 diabetes mellitus, insulin therapy, basal plus two times bolus insulin therapy, prandial premixed insulin therapy, Diabetes Treatment Satisfaction Questionnaire

  5. Rapid assessment of injection practices in Cambodia, 2002

    Directory of Open Access Journals (Sweden)

    Goldstein Susan

    2005-06-01

    Full Text Available Abstract Background Injection overuse and unsafe injection practices facilitate transmission of bloodborne pathogens such as hepatitis B virus (HBV, hepatitis C virus (HCV, and human immunodeficiency virus (HIV. Anecdotal reports of unsafe and unnecessary therapeutic injections and the high prevalence of HBV (8.0%, HCV (6.5%, and HIV (2.6% infection in Cambodia have raised concern over injection safety. To estimate the magnitude and patterns of such practices, a rapid assessment of injection practices was conducted. Methods We surveyed a random sample of the general population in Takeo Province and convenience samples of prescribers and injection providers in Takeo Province and Phnom Penh city regarding injection-related knowledge, attitudes, and practices. Injection providers were observed administering injections. Data were collected using standardized methods adapted from the World Health Organization safe injection assessment guidelines. Results Among the general population sample (n = 500, the overall injection rate was 5.9 injections per person-year, with 40% of participants reporting receipt of ≥ 1 injection during the previous 6 months. Therapeutic injections, intravenous infusions, and immunizations accounted for 74%, 16% and 10% of injections, respectively. The majority (>85% of injections were received in the private sector. All participants who recalled their last injection reported the injection was administered with a newly opened disposable syringe and needle. Prescribers (n = 60 reported that 47% of the total prescriptions they wrote included a therapeutic injection or infusion. Among injection providers (n = 60, 58% recapped the syringe after use and 13% did not dispose of the used needle and syringe appropriately. Over half (53% of the providers reported a needlestick injury during the previous 12 months. Ninety percent of prescribers and injection providers were aware HBV, HCV, and HIV were transmitted through unsafe

  6. Use of high concentration contrast media: principles and rationale--vascular district

    International Nuclear Information System (INIS)

    Fleischmann, Dominik.

    2003-01-01

    Optimal contrast medium delivery remains a crucial issue in CT angiography and it will become even more critical with continuously evolving, faster CT scanner technology. This review article first explains the fundamentals of arterial enhancement using mathematical models of early contrast medium dynamics. The relationship of contrast medium volume, injection flow rates and injection duration are explicitly illustrated. Next, current techniques of contrast medium application are reviewed, with particular attention to methods of accurate timing of the scanning delay (test-bolus and automated bolus triggering), tools for automated saline-flushing of the veins (double-syringe power injectors) and the use of high-concentration contrast medium. From there, rational CT angiographic injection protocols for a wide range of selectable acquisition times for 4-, 8- and 16-channel MDCT are proposed

  7. [Simultaneous determination of five effective components in Sijunzi bolus using high performance liquid chromatography-evaporation light scattering detection].

    Science.gov (United States)

    Li, Chunying; Zhang, Xiaojun

    2010-01-01

    A high performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of lobetyolin, pachymic acid, glycyrrhizic acid, atractylenoide III and atractylenolide I in Sijunzi bolus. The separation was performed on an HIQ SIL C18 V column (250 mm x 4.6 mm, 5 microm) with 0.5% acetic acid-methanol as the mobile phase of gradient elution at a flow rate of 1.0 mL/min. The detection was performed with an evaporation light scattering detector (ELSD) and the sample volume was 10 microL. The temperature of drift tube and heating grade of nebulizer was respectively set at 55 degrees C and 60% at 0.2 MPa of pressure. Nitrogen gas was used as carrier gas. Under the optimized conditions, there were good linear relationships between the logarithm values of mass concentration and the peak areas of lobetyolin, pachymic acid, glycyrrhizic acid, atractylenoide III and atractylenolide I in the ranges of 0.076 - 1.21, 0.048 -0.76, 0.153 - 2.45, 0.045 - 0.72 and 0.098 - 1.56 g/L, respectively. The recoveries of the five components were between 97.13% and 100.25%, the relative standard deviations (RSDs) were between 1.23% and 2.44%. This method is simple, rapid, accurate and suitable for the quality control of Sijunzi bolus.

  8. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    Total knee arthroplasty often results in marked postoperative pain. A recent meta-analysis supports the use of femoral nerve block or alternatively spinal injection of morphine plus local anaesthetic for post-operative analgesia. On the other hand, the use of intrathecal morphine may be associated with a large number of distressing side effects (itching, urinary retention, nausea and vomiting, delayed respiratory depression). The aim of this study was to compare the effectiveness of femoral nerve block and low dose intrathecal morphine in post-operative analgesia after primary unilateral total knee arthroplasty. Fifty-two consecutive patients scheduled for primary unilateral total knee arthroplasty were allocated to the intrathecal morphine group (ITM group) or to the femoral nerve block group (FNB group). In ITM group a subarachnoid puncture was performed at the L3-L4 inter-vertebral space with hyperbaric bupivacaine 15 mg plus 100 mcg of preservative-free morphine. Patients allocated to the FNB group received a single-injection ultrasound-assisted femoral nerve block with ropivacaine 0.75% 25 ml before the spinal injection of hyperbaric bupivacaine 15 mg. All patients received postoperative patient-controlled-analgesia (PCA) morphine, using a 1-mg bolus and a 5-minute lockout period. Data were analyzed using Student t test or two-way analysis of variance (ANOVA) for repeated measures with time and treatment as the 2 factors. Post hoc comparisons were performed by Bonferroni test. Statistical significance for all test was a p value < 0.05. Patient characteristics were similar between the 2 groups. We found a statistically significant differences in postoperative pain between the two groups: ITM group had the lower visual analogic pain score (VAS) values. Morphine consumption was lower in the ITM group: average consumption within the first 6 hours was 0.9 mg in IT group compared to 3.1 mg in FNB group; at 12 h 4.2 mg vs 6.3 mg; at 24 h 6.9 mg vs 10.3 mg; at 48 h 9

  9. Total intravenous anesthesia (TIVA) in an infant with Werdnig-Hoffmann disease. Case report.

    Science.gov (United States)

    de Resende, Marco Antonio Cardoso; da Silva, Elizabeth Vaz; Nascimento, Osvaldo José Moreira; Gemal, Alberto Esteves; Quintanilha, Giseli; Vasconcelos, Eliana Maria

    2010-01-01

    Werdnig-Hoffmann disease is the most common cause of hypotonia in infants and its prognosis is worse if it is present shortly after delivery. Symmetrical muscular weakness, areflexia, and fasciculations of the tongue are characteristic. The majority of the infants die before two years of age as a consequence of respiratory failure. The present report presents a case in which total intravenous anesthesia was used. This is a 1 year old white female weighing 10 kg, physical status ASA III, with Werdnig-Hoffmann disease diagnosed at two months of age. The patient was a candidate for open gastrostomy, fundus gastroplication, and tracheostomy. After venoclysis, the patient was monitored with cardioscope, non-invasive blood pressure, pulse oximeter, precordial stethoscope, and rectal temperature. She was oxygenated and, after bolus administration of atropine (0.3 mg), boluses of remifentanil (20 microg) and propofol (30 mg) were administered for anesthetic induction. After tracheal intubation, she was ventilated with manual controlled system without CO(2) absorber, Baraka (Mapleson D system), FGF of 4 L.min(-1), and FiO(2) 0.5 (O(2)/N(2)O). Anesthesia was maintained with continuous manual infusion of propofol, 250 microg x kg(-1) x min(-1), and remifentanil, 0.3 microg x kg(-1) x min(-1). The surgery lasted 150 minutes. The patient regained consciousness 8 minutes after the end of the infusion, ventilating spontaneously. Two hours later, she was transferred to the pediatric unit, being discharged from the hospital on the fourth postoperative day. The choice of anesthetic technique gives priority to the safety associated with the familiarity of handling available drugs. In children with neuromuscular diseases, due to the extremely short duration, total intravenous anesthesia with remifentanil and propofol in infusion systems can have a favorable influence on disease evolution.

  10. Intraurethral Injection of Autologous Minced Skeletal Muscle

    DEFF Research Database (Denmark)

    Gräs, Søren; Klarskov, Niels; Lose, Gunnar

    2014-01-01

    noted. CONCLUSIONS: Intraurethral injection of minced autologous muscle tissue is a simple surgical procedure that appears safe and moderately effective in women with uncomplicated stress urinary incontinence. It compares well to a more complicated regenerative strategy using in vitro expanded muscle......PURPOSE: Intraurethral injection of in vitro expanded autologous skeletal muscle derived cells is a new regenerative therapy for stress urinary incontinence. We examined the efficacy and safety of a simpler alternative strategy using freshly harvested, minced autologous skeletal muscle tissue...... with its inherent content of regenerative cells. MATERIALS AND METHODS: A total of 20 and 15 women with uncomplicated and complicated stress urinary incontinence, respectively, received intraurethral injections of minced autologous skeletal muscle tissue and were followed for 1 year. Efficacy was assessed...

  11. Intraoperative intra-articular injection of gentamicin: will it decrease the risk of infection in total shoulder arthroplasty?

    Science.gov (United States)

    Lovallo, Jeffrey; Helming, Jarrett; Jafari, S Mehdi; Owusu-Forfie, Afia; Donovan, Skye; Minnock, Christopher; Adib, Farshad

    2014-09-01

    Deep infection is a debilitating complication after shoulder arthroplasty. Intra-articular injection of antibiotic can give a higher concentration compared with intravenous administration. We hypothesized that a group of patients given an intra-articular, intraoperative injection of gentamicin would report a lower infection rate than a group without local antibiotics. Between 2005 and 2011, the senior author performed 507 shoulder arthroplasties. We retrospectively reviewed all of those cases. All patients were administered systemic prophylactic antibiotics. Beginning in June 2007, patients were also injected with 160 mg of gentamicin in the glenohumeral joint at the end of their surgery. Patient records were examined for preexisting medical conditions, type of surgery, and presence of infection. Patients receiving surgery before 2007 were compared with those after to determine the effect of prophylactic gentamicin administration in preventing deep infection associated with surgery. All patients were observed for a minimum of 1 year. Of the 507 surgeries, 164 were performed before 2007 (without intra-articular injection of gentamicin; group A) and 343 were performed with addition of gentamicin (group B). In group A, 5 patients presented with infection (3.0%) compared with 1 in group B (0.29%). The gender, mean age, mean body mass index, and prevalence of comorbidities were similar between the groups. The data from this study support the conclusion that intra-articular intraoperative gentamicin administration may reduce postoperative infection. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  12. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2012-02-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  13. Study protocol. ECSSIT - Elective Caesarean Section Syntocinon Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section.

    LENUS (Irish Health Repository)

    Murphy, Deirdre J

    2009-01-01

    BACKGROUND: Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4-10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. METHODS AND DESIGN: A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. DISCUSSION: It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  14. Periarticular Injection of Liposomal Bupivacaine Offers No Benefit Over Standard Bupivacaine in Total Knee Arthroplasty: A Prospective, Randomized, Controlled Trial.

    Science.gov (United States)

    Alijanipour, Pouya; Tan, Timothy L; Matthews, Christopher N; Viola, Jessica R; Purtill, James J; Rothman, Richard H; Parvizi, Javad; Austin, Matthew S

    2017-02-01

    Periarticular injection of liposomal bupivacaine has been adopted as part of multimodal pain management after total knee arthroplasty (TKA). In this prospective, randomized clinical trial, we enrolled 162 patients undergoing primary TKA in a single institution between January 2014 and May 2015. Eighty-seven patients were randomized to liposomal bupivacaine (experimental group), and 75 patients were randomized to free bupivacaine (control group). All patients received spinal anesthesia and otherwise identical surgical approaches, pain management, and rehabilitation protocols. Outcomes evaluated include the patient-reported visual analog pain scores, narcotic consumption, and narcotic-related side effects (Brief Pain Inventory) within 96 hours after surgery as well as functional outcomes using the Knee Society Score and the Short-Form 12 measured preoperatively and at 4-6 weeks after surgery. There were no statistically significant differences between the groups in terms of postoperative daily pain scores, narcotic consumption (by-day and overall), or narcotic-related side effects. There were no statistically significant differences between the groups in terms of surgical (P = .76) and medical complications or length of hospital stay (P = .35). There were no statistically significant differences in satisfaction between the groups (P = .56) or between the groups in postoperative Knee Society Score (P = .53) and the Short-Form 12 at 4-6 weeks (P = .82, P = .66). As part of multimodal pain management protocol, periarticular injection of liposomal bupivacaine compared with bupivacaine HCl did not result in any clinically or statistically significant improvement of the measured outcomes following TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Assessment of the safety of injection practices and injection-related procedures in family health units and centers in Alexandria.

    Science.gov (United States)

    Elhoseeny, Taghareed A; Mourad, Juidan K

    2014-08-01

    The Safe Injection Global Network (SIGN) developed an intervention strategy for reducing overuse of injections and promoting the administration of safe injections. Tool C--Revised is designed to assess the safety of the most common procedures that puncture the skin within health services. The aim of the study was to assess injection safety within the primary healthcare facilities in Alexandria using Tool C--Revised. A total of 45 family health units and centers in Alexandria were selected by proportional allocation from the eight regions of Alexandria. The Tool C--Revised of the WHO was used for observation of the entire facility, injection practices and injection-related procedures, and sterilization practices. Interview of different health providers and immediate supervisor of injections was carried out. Indicators that reflect risk included: deficiency of alcohol-based hand rub for cleansing hands (13.3%), compliance with hand wash before preparing a procedure (56.9% before injection practices, 61.3% before phlebotomy, and 67.6% before lancet puncture), and wearing a new pair of gloves before new procedures (48.6% before injection practices, 9.7% for phlebotomy, 11.8% for lancet puncture, and 80% for both intravenous injections and infusions). Enough disposable equipment in all facilities for at least 2 weeks dependent on the statement of the average numbers of procedures per week was shown. Only 38% of the providers had received training regarding injection safety in the last 2 years and 62.5% had completed their three doses of hepatitis B vaccine. Only 42.2% of staffs who handled healthcare waste had access to heavy gloves. Indicators related to injection and injection-related practices that reflect risk to patients include deficiency of alcohol-based hand rub tools, nonadherence to hand hygiene before preparing an injection, and inadequate adherence to using a clean barrier when opening a glass ampule and use of gloves. Indicators that may reflect risk to

  16. Experiment on performance of upper head injection system with ROSA-II

    International Nuclear Information System (INIS)

    1978-05-01

    Of the total 10 ROSA-II/UHI performance tests, 6 were reported previously. The rest are presented and discussion is made on the effects of heat generation in the core and UHI injection and repeatability of experiments. In addition, the following are described: (1) Pressure spikes observed in the upper head after sudden stoppage of UHI injection, and (2) discharge flow oscillation possibly due to UHI water injection into the upper plenum. (auth.)

  17. Remifentanil-based total intravenous anesthesia for pediatric rigid bronchoscopy: comparison of adjuvant propofol and ketamine

    Directory of Open Access Journals (Sweden)

    Mefkur Bakan

    2014-06-01

    Full Text Available OBJECTIVE:Laryngoscopy and stimuli inside the trachea cause an intense sympatho-adrenal response. Remifentanil seems to be the optimal opioid for rigid bronchoscopy due to its potent and short-acting properties. The purpose of this study was to compare bolus propofol and ketamine as an adjuvant to remifentanil-based total intravenous anesthesia for pediatric rigid bronchoscopy.MATERIALS AND METHODS:Forty children under 12 years of age who had been scheduled for a rigid bronchoscopy were included in this study. After midazolam premedication, a 1 µg/kg/min remifentanil infusion was started, and patients were randomly allocated to receive either propofol (Group P or ketamine (Group K as well as mivacurium for muscle relaxation. Anesthesia was maintained with a 1 µg/kg/min remifentanil infusion and bolus doses of propofol or ketamine. After the rigid bronchoscopy, 0.05 µg/kg/min of remifentanil was maintained until extubation. Hemodynamic parameters, emergence characteristics, and adverse events were evaluated.RESULTS:The demographic variables were comparable between the two groups. The decrease in mean arterial pressure from baseline values to the lowest values during rigid bronchoscopy was greater in Group P (p= 0.049, while the reduction in the other parameters and the incidence of adverse events were comparable between the two groups. The need for assisted or controlled mask ventilation after extubation was higher in Group K.CONCLUSION:Remifentanil-based total intravenous anesthesia with propofol or ketamine as an adjuvant drug along with controlled ventilation is a viable technique for pediatric rigid bronchoscopy. Ketamine does not provide a definite advantage over propofol with respect to hemodynamic stability during rigid bronchoscopy, while propofol seems more suitable during the recovery period.

  18. Can Repeat Injection Provide Clinical Benefit in Patients with Lumbosacral Diseases When First Epidural Injection Results Only in Partial Response?

    Science.gov (United States)

    Lee, Jung Hwan; Lee, Sang-Ho

    2016-02-01

    Epidural steroid injection (ESI) is known to be an effective treatment for lower back or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after a single ESI, there has been little evidence supporting the usefulness of repeat injections in cumulative clinical pain reduction. The purpose of this study was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than that provided by intermittent injection performed only when pain was aggravated. An Institutional Review Board (IRB)-approved retrospective chart review. Spine hospital. Two hundred and four patients who had underwent transforaminal ESI (TFESI) for treatment of lower back and radicular pain due to HIVD or SS and could be followed-up for one year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (NRS = 3 after first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 96) comprised partial responders who did not receive a repeat injection at the prescribed interval, but received repeat injections only for aggravation of pain. Various clinical data including total number of injections during one year, duration of NRS group A, or after first injection in group B (time to reinjection), were assessed. These data were compared between groups A and B in terms of total population, HIVD, and SS. In the whole population, the mean time to reinjection was 6.09 ± 3.02 months in group A and 3.69 ± 2.07 months in group B. The NRS groups A and B, respectively. In HIVD patients, the mean time to reinjection was 5.82 ± 3.23 months in group A and 3.84 ± 2.34 months in group B, and NRS groups A and B, respectively. In SS patients, the mean time to

  19. Accurate, safe, and rapid method of intraoperative tumor identification for totally laparoscopic distal gastrectomy: injection of mixed fluid of sodium hyaluronate and patent blue.

    Science.gov (United States)

    Nakagawa, Masatoshi; Ehara, Kazuhisa; Ueno, Masaki; Tanaka, Tsuyoshi; Kaida, Sachiko; Udagawa, Harushi

    2014-04-01

    In totally laparoscopic distal gastrectomy, determining the resection line with safe proximal margins is often difficult, particularly for tumors located in a relatively upper area. This is because, in contrast to open surgery, identifying lesions by palpating or opening the stomach is essentially impossible. This study introduces a useful method of tumor identification that is accurate, safe, and rapid. On the operation day, after inducing general anesthesia, a mixture of sodium hyaluronate and patent blue is injected into the submucosal layer of the proximal margin. When resecting stomach, all marker spots should be on the resected side. In all cases, the proximal margin is examined histologically by using frozen sections during the operation. From October 2009 to September 2011, a prospective study that evaluated this method was performed. A total of 34 patients who underwent totally laparoscopic distal gastrectomy were enrolled in this study. Approximately 5 min was required to complete the procedure. Proximal margins were negative in all cases, and the mean ± standard deviation length of the proximal margin was 23.5 ± 12.8 mm. No side effects, such as allergy, were encountered. As a method of tumor identification for totally laparoscopic distal gastrectomy, this procedure appears accurate, safe, and rapid.

  20. Hyaluronic Acid Injections Are Associated with Delay of Total Knee Replacement Surgery in Patients with Knee Osteoarthritis: Evidence from a Large U.S. Health Claims Database.

    Directory of Open Access Journals (Sweden)

    Roy Altman

    Full Text Available The growing prevalence of osteoarthritis (OA and the medical costs associated with total knee replacement (TKR surgery for end-stage OA motivate a search for agents that can delay OA progression. We test a hypothesis that hyaluronic acid (HA injection is associated with delay of TKR in a dose-dependent manner.We retrospectively evaluated records in an administrative claims database of ~79 million patients, to identify all patients with knee OA who received TKR during a 6-year period. Only patients with continuous plan enrollment from diagnosis until TKR were included, so that complete medical records were available. OA diagnosis was the index event and we evaluated time-to-TKR as a function of the number of HA injections. The database included 182,022 patients with knee OA who had TKR; 50,349 (27.7% of these patients were classified as HA Users, receiving ≥1 courses of HA prior to TKR, while 131,673 patients (72.3% were HA Non-users prior to TKR, receiving no HA. Cox proportional hazards modelling shows that TKR risk decreases as a function of the number of HA injection courses, if patient age, gender, and disease comorbidity are used as background covariates. Multiple HA injections are therefore associated with delay of TKR (all, P < 0.0001. Half of HA Non-users had a TKR by 114 days post-diagnosis of knee OA, whereas half of HA Users had a TKR by 484 days post-diagnosis (χ2 = 19,769; p < 0.0001. Patients who received no HA had a mean time-to-TKR of 0.7 years; with one course of HA, the mean time to TKR was 1.4 years (χ2 = 13,725; p < 0.0001; patients who received ≥5 courses delayed TKR by 3.6 years (χ2 = 19,935; p < 0.0001.HA injection in patients with knee OA is associated with a dose-dependent increase in time-to-TKR.

  1. Intratracheal Milrinone Bolus Administration During Acute Right Ventricular Dysfunction After Cardiopulmonary Bypass.

    Science.gov (United States)

    Gebhard, Caroline Eva; Desjardins, Georges; Gebhard, Cathérine; Gavra, Paul; Denault, André Y

    2017-04-01

    To evaluate intratracheal milrinone (tMil) administration for rapid treatment of right ventricular (RV) dysfunction as a novel route after cardiopulmonary bypass. Retrospective analysis. Single-center study. The study comprised 7 patients undergoing cardiac surgery who exhibited acute RV dysfunction after cardiopulmonary bypass. After difficult weaning caused by cardiopulmonary bypass-induced acute RV dysfunction, milrinone was administered as a 5-mg bolus inside the endotracheal tube. RV function improvement, as indicated by decreasing pulmonary artery pressure and changes of RV waveforms, was observed in all 7 patients. Adverse effects of tMil included dynamic RV outflow tract obstruction (2 patients) and a decrease in systemic mean arterial pressure (1 patient). tMil may be an effective, rapid, and easily applicable therapeutic alternative to inhaled milrinone for the treatment of acute RV failure during cardiac surgery. However, sufficiently powered clinical trials are needed to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The Effect of Rheological Properties of Foods on Bolus Characteristics After Mastication

    Science.gov (United States)

    Hwang, Junah; Bae, Jung Hyun; Kang, Si Hyun; Seo, Kyung Mook; Kim, Byong Ki; Lee, Sook Young

    2012-01-01

    Objective To evaluate the effects of physical properties of foods on the changes of viscosity and mass as well as the particle size distribution after mastication. Method Twenty subjects with no masticatory disorders were recruited. Six grams of four solid foods of different textures (banana, tofu, cooked-rice, cookie) were provided, and the viscosity and mass after 10, 20, and 30 cycles of mastication and just before swallowing were measured. The physical properties of foods, such as hardness, cohesiveness, and adhesiveness, were measured with a texture analyzer. Wet sieving and laser diffraction were used to determine the distribution of food particle size. Results When we measured the physical characteristics of foods, the cookie was the hardest food, and the banana exhibited marked adhesiveness. Tofu and cooked-rice exhibited a highly cohesive nature. As the number of mastication cycles increased, the masses of all foods were significantly increased (pmastication (pmastication process and food bolus formation were affected by the physical properties of the food. PMID:23342309

  3. Accuracy of MRI-compatible contrast media injectors.

    Science.gov (United States)

    Saake, M; Wuest, W; Becker, S; Uder, M; Janka, R

    2014-03-01

    To analyze the exactness of MRI-compatible contrast media (CM) injectors in an experimental setup and clinical use. Ejected fluid volumes and amounts of CM were quantified for single and double piston injections. The focus was on small volumes, as used in pediatric examination and test-bolus measurements. Samples were collected before and after clinical MRI scans and amounts of CM were measured. For single piston injections the volume differences were minimal (mean difference 0.01  ml). For double piston injections the volume of the first injection was decreased (mean 20.74  ml, target 21.00  ml, p pistons of modern CM injectors work exactly. However, for small CM volumes the injected amount of CM can differ significantly from the target value in both directions. Influence factors are an incomplete elimination of air and exchange processes between the CM and saline chaser in the injection system. • In MRI examinations of children and test-bolus measurements, small amounts of CM are used. • The accuracy of single piston injections is high. • In double piston injections the injected amount of CM can differ significantly from the target value. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Internal transport barrier formation and pellet injection simulation in helical and tokamak reactors

    International Nuclear Information System (INIS)

    Higashiyama, You; Yamazaki, Kozo; Arimoto, Hideki; Garcia, Jeronimo

    2008-01-01

    In the future fusion reactor, plasma density peaking is important for increase in the fusion power gain and for achievement of confinement improvement mode. Density control and internal transport barrier (ITB) formation due to pellet injection have been simulated in tokamak and helical reactors using the toroidal transport linkage code TOTAL. First, pellet injection simulation is carried out, including the neutral gas shielding model and the mass relocation model in the TOTAL code, and the effectiveness of high-field side (HFS) pellet injection is clarified. Second, ITB simulation with pellet injection is carried out with the confinement improvement model based on the E x B shear effects, and it is found that deep pellet penetration is helpful for ITB formation as well as plasma core fuelling in the reversed-shear tokamak and helical reactors. (author)

  5. Factors associated with pathways toward concurrent sex work and injection drug use among female sex workers who inject drugs in northern Mexico.

    Science.gov (United States)

    Morris, Meghan D; Lemus, Hector; Wagner, Karla D; Martinez, Gustavo; Lozada, Remedios; Gómez, Rangel María Gudelia; Strathdee, Steffanie A

    2013-01-01

    To identify factors associated with time to initiation of (i) sex work prior to injecting drugs initiation; (ii) injection drug use prior to sex work initiation; and (iii) concurrent sex work and injection drug use (i.e. initiated at the same age) among female sex workers who currently inject drugs (FSW-IDU). Parametric survival analysis of baseline data for time to initiation event. Tijuana and Ciudad Juarez situated on the Mexico-US border. A total of 557 FSW-IDUs aged ≥18 years. Interview-administered surveys assessing context of sex work and injection drug use initiation. Nearly half (n = 258) initiated sex work prior to beginning to inject, a third (n = 163) initiated injection first and a quarter (n = 136) initiated both sex work and injection drug use concurrently. Low education and living in Ciudad Juarez accelerated time to sex work initiation. Being from a southern Mexican state and initiating drug use with inhalants delayed the time to first injection drug use. Having an intimate partner encourage entry into sex work and first injecting drugs to deal with depression accelerated time to initiating sex work and injection concurrently. Early physical abuse accelerated time to initiating sex work and injection, and substantially accelerated time to initiation of both behaviors concurrently. Among female sex workers who currently inject drugs in two Mexican-US border cities, nearly half appear to initiate sex work prior to beginning to inject, nearly one-third initiate injection drug use before beginning sex work and one-quarter initiate both behaviors concurrently. Predictors of these three trajectories differ, and this provides possible modifiable targets for prevention. © 2012 The Authors, Addiction © 2012 Society for the Study of Addiction.

  6. Thermal hydraulic analysis of aggressive secondary cooldown in small break loss of coolant accident with total loss of high pressure safety injection

    International Nuclear Information System (INIS)

    Han, S. J.; Im, H. K.; Yang, J. U.

    2003-01-01

    Recently, Probabilistic Safety Assessment (PSA) has being applied to various fields as a basic technique of Risk-Informed Applications (RIA). To use RIA, the present study focuses on the detailed thermal hydraulic analyses for major accident sequences and success criteria to support a development of PSA model for Korea Standard Nuclear Power plant (KSNP). The primary purpose of the present study is to evaluate the success criteria of Aggressive Secondary Cooldown (ASC) in Small Break Loss Of Coolant Accident (SBLOCA) with total loss of High Pressure Safety Injection (HPSI) and to enhance the understanding of related thermal hydraulic behavior and phenomena. The accident scenario was 2 inch coldleg break LOCA without HPSI, with 1/2 Low Pressure Safety Injection (LPSI), and performing ASC limited by 55.6 .deg. C /hr (100 .deg. F/hr) cooldown rate at 15 minute after reactor trip, which successively reaches the LPSI condition for about 1.5hr after starting ASC operation with the Peak Cladding Temperature (PCT) of the hottest rod below the core damage criteria 1204.4 .deg. C (2200 .deg. F). In the present study, more relaxed success criteria than the previous PSA for KSNP could be generated under an assumption that operator should maintain the adequate ASC operation. However, it is necessary to evaluate uncertainties arisen from the related parameters of the ASC operation

  7. Low energy, high power injection in JT-60 NBI

    International Nuclear Information System (INIS)

    Mizuno, Makoto; Dairaku, Masayuki; Horiike, Hiroshi

    1988-05-01

    JT-60 neutral beam injector (JT-60 NBI) is designed to inject 20 MW neutral hydrogen beam at energies of 70 ∼ 100 keV and the injection power decreases significantly at low energies (∼40 keV). For the extention of operation region aiming at the low density plasma heating and achieving H-mode by plasma periphery heating, increment of the injection power at low beam energies was required. The single-stage acceleration system was investigated in advance at the Prototype Injector Unit. From this result, the total injection power of 17 MW at 40 keV, 48 A per source was expected at the JT-60 NBI. This system was adopted in the JT-60 NBI from June, 1987 to July, 1987 and 17.6 MW neutral beam injection power was achieved. In the NB heating experiment, the H-mode transition phenomena was observed in JT-60 plasma. (author)

  8. Autologous Blood Injection Works for Recalcitrant Lateral Epicondylitis.

    Science.gov (United States)

    Bostan, Bora; Balta, Orhan; Aşçı, Murat; Aytekin, Kürşad; Eser, Enes

    2016-03-01

    Recalcitrant lateral epicondylitis may be a disabling condition. Treatment of this condition is still controversial. In the present prospective study, we evaluated the long-term results of autologous blood injection for the treatment of recalcitrant lateral epicondylitis. Prospective clinical study. A total of 42 elbows of 40 consecutive patients (28 female, 12 male) were enrolled in this prospective study. Seven patients left the study (3 patients moved to another city, 1 patient died in the second week due to a heart condition, 1 patient quit the study because of the resolution of pain in the fourth week and 2 patients did not agree to the second injection). Thirteen patients were lost to third year follow-up. Therefore, a total of 21 elbows of 20 patients with 3 years of follow-up were included in this study. The mean age of the patients was 47.25 years (range, 20-68 years). Visual analogue scale (VAS), Nirschl score and grip strength were significantly improved after injections when compared to before treatment. The best improvement in terms of grip strength, Nirschl score and VAS score was detected at the one year follow-up. The improvement in Nirschl and VAS score sustained until the third year. We suggest that autologous blood injection for the treatment of recalcitrant lateral epicondylitis is an effective, safe and successful procedure in the long-term.

  9. Experimental research of percutaneous intrahepatic ethanol injection under CT guidance

    International Nuclear Information System (INIS)

    Kang Deqiang; Tian Jianming; Xiang Cheng; Zhang Feng; Zuo Changjing; Zang Tingzhen; Shi Lijing; Yuan Xiaodong; Tian Yuan; Li Shijian

    2005-01-01

    Objective: To study percutaneous ethanol injection caused liver injures on rabbits with different doses, concentrations and temperatures. Methods: The experiment was carried out in 54 New Zealand rabbits under randomized dividing groups with the purpose of observing the microscopic pathologic changes after 1 day, 1 week, 2 weeks of ethanol injection and the blood sampling biochemical with imaging changes, 1, 3, 7, 10, 14 days before and after injection. Results: Both total ethanol dose and concentration can cause different size of necrosis on rabbits liver tissue with the interactions between them. Pathologic changes in rabbits liver appeared to be typical coagulative necrosis. The injuries causes by ethanol injection were transient and repairable after a short period. Conclusions: Percutaneous ethanol injection causes mild injures to the liver. The method is safe and practicable. (authors)

  10. A Comparison of Inpatient Cost Per Day in General Surgery Patients with Type 2 Diabetes Treated with Basal-Bolus versus Sliding Scale Insulin Regimens.

    Science.gov (United States)

    Phillips, Victoria L; Byrd, Anwar L; Adeel, Saira; Peng, Limin; Smiley, Dawn D; Umpierrez, Guillermo E

    2017-01-01

    The identification of cost-effective glycaemic management strategies is critical to hospitals. Treatment with a basal-bolus insulin (BBI) regimen has been shown to result in better glycaemic control and fewer complications than sliding scale regular insulin (SSI) in general surgery patients with type 2 diabetes mellitus (T2DM), but the effect on costs is unknown. We conducted a post hoc analysis of the RABBIT Surgery trial to examine whether total inpatient costs per day for general surgery patients with T2DM treated with BBI ( n  = 103) differed from those for patients with T2DM treated with SSI ( n  = 99) regimens. Data were collected from patient clinical and hospital billing records. Charges were adjusted to reflect hospital costs. General linearized models were used to estimate the risk-adjusted effects of BBI versus SSI treatment on average total inpatient costs per day. Risk-adjusted average total inpatient costs per day were $US5404. Treatment with BBI compared with SSI reduced average total inpatient costs per day by $US751 (14%; 95% confidence interval [CI] 20-4). Being treated in a university medical centre, being African American or having a bowel procedure or higher-volume pharmacy use significantly reduced costs per day. In general surgery patients with T2DM, a BBI regimen significantly reduced average total hospital costs per day compared with an SSI regimen. BBI has been shown to improve outcomes in a randomized controlled trial. Those results, combined with our findings regarding savings, suggest that hospitals should consider adopting BBI regimens in patients with T2DM undergoing surgery.

  11. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  12. Lowering postprandial glycemia in children with type 1 diabetes after Italian pizza "margherita" (TyBoDi2 Study).

    Science.gov (United States)

    De Palma, Alessandra; Giani, Elisa; Iafusco, Dario; Bosetti, Alessandra; Macedoni, Maddalena; Gazzarri, Alessandra; Spiri, Daniele; Scaramuzza, Andrea E; Zuccotti, Gian Vincenzo

    2011-04-01

    Continuous subcutaneous insulin infusion is considered a safe and effective way to administer insulin in pediatric patients with type 1 diabetes, but achieving satisfactory and stable glycemic control is difficult. Several factors contribute to control, including fine-tuning the basal infusion rate and bolus type and timing. We evaluated the most effective type and timing of a pump-delivered, preprandial bolus in children with type 1 diabetes for a pizza "margherita" meal. We assessed the response of 38 children with type 1 diabetes to a meal based on pizza "margherita" (with mozzarella cheese and tomato sauce) after different types and timings of a bolus dose. The glucose levels for 6 h after the meal were lower (i.e., closer to the therapeutic target of pizza "margherita," our data support the injection of the simple bolus 15 min before a meal, rather than immediately before or delivered as a double-wave bolus, to control the glycemic rise usually observed.

  13. Rapid food decomposition by H2O2-H2SO4 for determination of total mercury by flow injection cold vapor atomic absorption spectrometry.

    Science.gov (United States)

    Zenebon, Odair; Sakuma, Alice M; Dovidauskas, Sergio; Okada, Isaura A; de, MaioFrancaD; Lichtig, Jaim

    2002-01-01

    A mixture of 50% H2O2-H2SO4 (3 + 1, v/v) was used for decomposition of food in open vessels at 80 degrees C. The treatment allowed rapid total mercury determination by flow injection cold vapor atomic absorption spectrometry. Cabbage, potatoes, peanuts paste, hazelnuts paste, oats, tomatoes and their derivatives, oysters, shrimps, prawns, shellfish, marine algae, and many kinds of fish were analyzed by the proposed methodology with a limit of quantitation of 0.86 +/- 0.08 microg/L mercury in the final solution. Reference materials tested also gave excellent recovery.

  14. Renal enhancement and excretion of the hepatobiliary contrast agent Gd-EOB-DTPA

    International Nuclear Information System (INIS)

    Zangos, S.; Hammerstingl, R.; Mack, M.G.; Straub, R.; Engelmann, K.; Eichler, K.; Vogl, T.J.

    2001-01-01

    Purpose: To evaluate the clinical value of the renal clearance using MR imaging with different doses of gadolinium ethoxybenzyl-DTPA (Gd-EOB-DTPA) in comparison to gadolinium DTPA (Gd-DTPA). Material and Methods: In a double-blind and randomized clinical phase II study. MR imaging at 1.5 T was performed in 61 patients with five different doses of Gd-EOB-DTPA (3, 6, 12.5, 25 and 50 μmol/kg b.w. as a bolus injection). The study protocol comprised T 1 - and T 2 -weighted spin-echo magnetic resonance and two-dimensional fast low-angle shot imaging before and at increasing intervals for up to 45 min after injection of Gd-EOB-DTPA. These images were compared with Gd-DTPA-enhanced imaging (0.1 mmol/kg b. w. as a bolus injection). Results: After bolus injection of the hepatobiliary MR contrast agent Gd-EOB-DTPA a renal elimination was observed. Immediately after the injection of Gd-EOB-DTPA until the eighth minute a corticomedullary enhancement of the kidney was conspicuous. After the fourth minute a contrast enhancement could be seen in the renal pelvis. The best enhancement was noted after 20 minutes in the FLASH GRE and T 1 -weighted images with good pelvicaliceal contrast. After 45 minutes an outflow of Gd-EOB-DTPA into the ureter could be observed. Conclusion: In addition to the hepatobiliary secretion Gd-EOB-DTPA appears useful for the evaluation of renal structures and renal function on account of the renal excretion without diuretic preparation of the patients. (orig.) [de

  15. Methylene blue administration in the compound 48/80-induced anaphylactic shock: hemodynamic study in pigs Administração de azul de metileno no choque anafilático induzido por composto 48/80: estudo hemodinâmico em suínos

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Menardi

    2011-12-01

    Full Text Available PURPOSE: To verify if the methylene blue (MB administration prevents and/or reverses the compound 48/80 (C48/80-induced anaphylactic shock in pigs. METHODS: Female Dalland pigs were anesthetized and had the hemodynamic parameters recorded during the necessary time to administer some drugs and observe their effect. The animals were randomly assigned to one of the five groups: 1 control; 2 MB: the animals received a bolus injection of MB (2 mg/kg followed by continuous infusion of MB (2.66 mg/Kg/h delivered by syringe infusion pump; 3 C48/80: the animals received a bolus injection of C48/80 (4 mg/kg; 4 C48/80+MB: the animals received a bolus injection of C48/80 (4 mg/kg and 10 minutes after the C48/80 administration the animals received a bolus injection of MB (2 mg/kg followed by continuous infusion of MB (2.66 mg/Kg/h delivered by syringe infusion pump; 5 MB+C48/80: the animals received a bolus injection of MB (2 mg/kg and 3 minutes later they received a bolus injection of C48/80 (4 mg/kg. RESULTS: The intravenous infusion of MB alone caused no changes in the mean arterial pressure (MAP showing that the administered MB dose was safe in this experimental model. The C48/80 was effective in producing experimental anaphylactic shock since it was observed a decrease in both MAP and cardiac output (CO after its administration. The MB did not prevent or reverse the C48/80-induced anaphylactic shock in this model. In fact, the MAP of the animals with anaphylactic shock treated with MB decreased even more than the MAP of the animals from the C48/80 group. On the other hand, the C48/80-induced epidermal alterations disappeared after the MB infusion. CONCLUSION: Despite our data, the clinical manifestations improvement brings some optimism and does not allow excluding the MB as a possible therapeutic option in the anaphylactic shock.OBJETIVO: Verificar se a administração de azul de metileno (AM previne e/ou reverte o choque anafilático induzido por

  16. Failure of botulinum toxin injection for neurogenic detrusor overactivity: Switch of toxin versus second injection of the same toxin.

    Science.gov (United States)

    Peyronnet, Benoit; Castel-Lacanal, Evelyne; Manunta, Andréa; Roumiguié, Mathieu; Marque, Philippe; Rischmann, Pascal; Gamé, Xavier

    2015-12-01

    To evaluate the efficacy of a second injection of the same toxin versus switching to a different botulinum toxin A after failure of a first detrusor injection in patients with neurogenic detrusor overactivity. The charts of all patients who underwent detrusor injections of botulinum toxin A (either abobotulinumtoxinA or onabotulinumtoxinA) for the management of neurogenic detrusor overactivity at a single institution were retrospectively reviewed. Patients in whom a first detrusor injection had failed were included in the present study. They were managed by a second injection of the same toxin at the same dosage or by a new detrusor injection using a different botulinum toxin A. Success was defined as a resolution of urgency, urinary incontinence and detrusor overactivity in a patient self-catheterizing seven times or less per 24 h. A total of 58 patients were included for analysis. A toxin switch was carried out in 29 patients, whereas the other 29 patients received a reinjection of the same toxin at the same dose. The success rate was higher in patients who received a toxin switch (51.7% vs. 24.1%, P = 0.03). Patients treated with a switch from abobotulinumtoxinA to onabotulinumtoxinA and those treated with a switch from onabotulinumtoxinA to abobotulinumtoxinA had similar success rates (52.9% vs. 50%, P = 0.88). After failure of a first detrusor injection of botulinum toxin for neurogenic detrusor overactivity, a switch to a different toxin seems to be more effective than a second injection of the same toxin. The replacement of onabotulinumtoxin by abobotulinumtoxin or the reverse provides similar results. © 2015 The Japanese Urological Association.

  17. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  18. Evaluation of the effect of bolus administration of 50% dextrose solution on measures of electrolyte and energy balance in postpartum dairy cows.

    Science.gov (United States)

    Wagner, Sarah A; Schimek, Daniel E

    2010-09-01

    To determine the effect of IV administration of a bolus of 50% dextrose solution on electrolyte and energy balance and effect of blood collection site on serum electrolyte values in postparturient dairy cows. 24 clinically normal multiparous cows. A bolus of 50% dextrose solution (0.5 L [n=8 cows]), 50% dextrose solution (1.0 L [8]), or saline (0.9% NaCl) solution (1.0 L, control treatment [8]) was administered via jugular venipuncture 5 to 10 days after parturition. Pretreatment and posttreatment blood samples were analyzed for concentrations of calcium, magnesium, phosphorus, potassium, glucose, insulin, beta-hydroxybutyric acid (BHBA), and nonesterified fatty acids. Coccygeal vessel and jugular vein blood samples were obtained prior to treatment, and electrolyte concentrations were compared. Treatment with 50% dextrose decreased phosphorus concentration in serum, compared with the control treatment. Suppression of BHBA and nonesterified fatty acid concentrations following dextrose treatment lasted for dextrose solution may be at risk for hypophosphatemia, and 1 treatment with 0.5 or 1 L of 50% dextrose solution is unlikely to prevent or resolve acetonemia (ketosis). The risk of hypophosphatemia may be underestimated when coccygeal vessel blood samples are used for diagnosis.

  19. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  20. A protocol for the retina surgeon's safe initial intravitreal injections.

    Science.gov (United States)

    Frenkel, Ronald E P; Haji, Shamim A; La, Melvin; Frenkel, Max P C; Reyes, Angela

    2010-11-10

    To determine the safety of a surgeon's initial consecutive intravitreal injections using a specific protocol and to review the complications that may be attributed to the injection procedure. A retrospective chart review. Fifty-nine patients (30 females, 29 males) received intravitreal injections of pegaptanib, bevacizumab, or ranibizumab as part of their treatment for neovascular age-related macular degeneration. The average patient age was 80 years. Twenty-two patients were diagnosed with or suspected of having glaucoma. Each patient received an average of 5.8 injections. The charts of 59 patients who received a total of 345 intravitreal injections (104 pegaptanib, 74 bevacizumab, 167 ranibizumab) were reviewed. All injections were performed in an office-based setting. Povidone-iodine, topical antibiotics, and eye speculum were used as part of the pre injection procedure. Vision and intraocular pressure were evaluated immediately following each injection. Incidence of post injection complications, including but not limited to endophthalmitis, retinal detachment, traumatic cataract, and vitreous hemorrhage. There were no cases of endophthalmitis, toxic reactions, traumatic cataracts, retinal detachment, or vitreous hemorrhage. There was one case each of lid swelling, transient floaters, retinal pigment epithelial tear, corneal edema, and corneal abrasion. There were five cases of transient no light perception following pegaptanib injections. The incidence of serious complications was very low for the intravitreal injections given. A surgeon's initial intravitreal injections may be performed with a very high degree of safety using this protocol.

  1. Autologous Blood Injection Works for Recalcitrant Lateral Epicondylitis

    Directory of Open Access Journals (Sweden)

    Bora Bostan

    2016-04-01

    Full Text Available Background: Recalcitrant lateral epicondylitis may be a disabling condition. Treatment of this condition is still controversial. Aims: In the present prospective study, we evaluated the long-term results of autologous blood injection for the treatment of recalcitrant lateral epicondylitis. Study Design: Prospective clinical study. Methods: A total of 42 elbows of 40 consecutive patients (28 female, 12 male were enrolled in this prospective study. Seven patients left the study (3 patients moved to another city, 1 patient died in the second week due to a heart condition, 1 patient quit the study because of the resolution of pain in the fourth week and 2 patients did not agree to the second injection. Thirteen patients were lost to third year follow-up. Therefore, a total of 21 elbows of 20 patients with 3 years of follow-up were included in this study. The mean age of the patients was 47.25 years (range, 20-68 years. Results: Visual analogue scale (VAS, Nirschl score and grip strength were significantly improved after injections when compared to before treatment. The best improvement in terms of grip strength, Nirschl score and VAS score was detected at the one year follow-up. The improvement in Nirschl and VAS score sustained until the third year. Conclusion: We suggest that autologous blood injection for the treatment of recalcitrant lateral epicondylitis is an effective, safe and successful procedure in the long-term.

  2. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  3. Injection and accumulation method in the TARN

    International Nuclear Information System (INIS)

    Yamada, S.; Katayama, T.

    1979-03-01

    The test accumulation ring for NUMATRON (TARN) is being constructed at INS, University of Tokyo. The main purpose of the TARN is to establish some techniques related to beam injection and RF stacking, ultrahigh vacuum, and beam monitoring and handling. In this paper, the injection and accumulation methods in the TARN are described. The combination of multiturn injection and RF stacking is applied to the TARN. Heavy ions from the INS sector focusing (SF) cyclotron are injection through a magnetic and an electrostatic inflectors. Two pulse magnets and a bump field excited by square wave current are used for the multiturn injection method. The procedure of the RF stacking is as follows. The beam from the cyclotron is transported to the ring, and is injected by a multiturn method. Then, the RF accelerating voltage is put on, and the beam is captured in the stable region of the RF acceleration. The RF voltage and the frequency are adiabatically changed, and the beam is moved to the stacking orbit. The RF voltage is put off, and the beam remains on the stacking orbit. In the present system, a repetitive stacking scheme is applied for the RF stacking. The momentum spread after the RF stacking is approximately proportional to the stacking number in synchrotron phase space. The stacking number is chosen so that the total aperture required for the combined method may not exceed the available aperture in the ring doughnut. (Kato, T.)

  4. A qualitative feasibility study to inform a randomised controlled trial of fluid bolus therapy in septic shock

    Science.gov (United States)

    O’Hara, Caitlin B; Canter, Ruth R; Mouncey, Paul R; Carter, Anjali; Jones, Nicola; Nadel, Simon; Peters, Mark J; Lyttle, Mark D; Harrison, David A; Rowan, Kathryn M; Inwald, David; Woolfall, Kerry

    2018-01-01

    Objective The Fluids in Shock (FiSh) Trial proposes to evaluate whether restrictive fluid bolus therapy (10 mL/kg) is more beneficial than current recommended practice (20 mL/kg) in the resuscitation of children with septic shock in the UK. This qualitative feasibility study aimed to explore acceptability of the FiSh Trial, including research without prior consent (RWPC), potential barriers to recruitment and participant information for a pilot trial. Design Qualitative interview study involving parents of children who had presented to a UK emergency department or been admitted to a paediatric intensive care unit with severe infection in the previous 3 years. Participants Twenty-one parents (seven bereaved) were interviewed 16 (median) months since their child’s hospital admission (range: 1–41). Results All parents said they would have provided consent for the use of their child’s data in the FiSh Trial. The majority were unfamiliar with RWPC, yet supported its use. Parents were initially concerned about the change from currently recommended treatment, yet were reassured by explanations of the current evidence base, fluid bolus therapy and monitoring procedures. Parents made recommendations about the timing of the research discussion and content of participant information. Bereaved parents stated that recruiters should not discuss research immediately after a child’s death, but supported a personalised postal ‘opt-out’ approach to consent. Conclusions Findings show that parents whose child has experienced severe infection supported the proposed FiSh Trial, including the use of RWPC. Parents’ views informed the development of the pilot trial protocol and site staff training. Trial registration number ISRCTN15244462—results. PMID:28847877

  5. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  6. Perbandingan Efek Pemberian Norepinefrin Bolus Intravena dengan Norepinefrin Infus Kontinu dalam Tatalaksana Hipotensi, Laju Nadi, dan Nilai APGAR pada Seksio Sesarea dengan Anestesi Spinal

    Directory of Open Access Journals (Sweden)

    Fitri Sepviyanti Sumardi

    2015-04-01

    Full Text Available Vasopresors are commonly used for the treatment of hypotension in spinal anesthesia for cesarean section. This research aimed to compare intravenous bolus of norepinephrine to continuous infusion of norepinephrine effectiveness in hypotension management in caesarean section patient under spinal anesthesia and their effect on heart rate and APGAR Score, The experimental study was conducted in a double-blind randomized manner to 44 American Society of Anesthesiologist (ASA physical status II pregnant women undergoing cesarean section with spinal anesthesia in Dr. Hasan Sadikin General Hospital Bandung within the period of September to -November 2013. The Study subjects were grouped into two groups, the first group received 4 µg intravenous bolus of norepinephrine group (NB and and the second received 8 µg/minute continuous infusion of norepinephrine group (NK. Data were analyzed by t-test, Mann-Whitney test, chi-square and analysis of variance (ANOVA t-test with p0.05. Conclusion from this study is the administration of norepinephrine in both ways can be used for the treatment of hypotension of spinal anesthesia without affecting the heart rate and APGAR score

  7. Ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a hot strongly magnetized plasma

    OpenAIRE

    Liu, Wei; Hsu, Scott C.

    2010-01-01

    We present results from three-dimensional ideal magnetohydrodynamic simulations of unmagnetized dense plasma jet injection into a uniform hot strongly magnetized plasma, with the aim of providing insight into core fueling of a tokamak with parameters relevant for ITER and NSTX (National Spherical Torus Experiment). Unmagnetized dense plasma jet injection is similar to compact toroid injection but with much higher plasma density and total mass, and consequently lower required injection velocit...

  8. Autologous platelet lysate local injections for the treatment of refractory lateral epicondylitis.

    Science.gov (United States)

    Tan, Xun-xiang; Ju, Hai-yang; Yan, Wei; Jiang, Hong-jiang; Su, Jin-ping; Dong, Hua-jun; Wang, Ling-shuang; Zou, De-bao

    2016-01-25

    The purpose of this study was to investigate the efficacy and safety of autologous platelet lysate (APL) local injections in reducing pain and improving function in patients with refractory lateral epicondylitis. A total of 56 patients with refractory lateral epicondylitis were enrolled in this study. All the patients received three injections in one course of treatment. Subjective assessments include visual analog scale (VAS) pain score and Mayo elbow score before injection (baseline) and at 1, 6, and 12 months after injection. Significant differences were observed in VAS and Mayo scores at baseline and at 1, 6, and 12 months after injection. Overall, the injections of APL improved local symptoms and all the patients recovered to normal elbow function with 12 months follow-up. Local injections of APL resulted in favorable clinical outcomes for the treatment of lateral epicondylitis. APL could be clinically effective in the treatment of lateral epicondylitis.

  9. Conceptual design of a neutral-beam injection system for the TFTR

    International Nuclear Information System (INIS)

    Ehlers, K.W.; Berkner, K.H.; Cooper, W.S.; Hooper, E.B.; Pyle, R.V.; Stearns, J.W.

    1975-11-01

    The neutral-beam injection requirements for heating and fueling the next generation of fusion reactor experiments far exceed those of present devices; the neutral-beam systems needed to meet these requirements will be large and complex. A conceptual design of a TFTR tokamak injection system to produce 120 keV deuterium-ion beams with a total power of about 80 MW is given

  10. Reducing the radiation dose to the eye lens region during CT brain examination: the potential beneficial effect of the combined use of bolus and a bismuth shield

    International Nuclear Information System (INIS)

    Lai, C.W.K.; Chan, T.P.; Cheung, H.Y.; Wong, T.H.

    2015-01-01

    Objective: Computed Tomography (CT) is the leading contributor to medical exposure to ionizing radiation. Although the use of CT brain scans for patients with head injuries and convulsions has shown a tremendous growth, it has raised substantial concerns in the general public because of the risk of radiation-induced cataracts: the current available strategies to reduce the radiation dose to the eye lens region are limited. Therefore, the present research project was initiated with the aim of evaluating the potential benefit of the combined use of bolus and a bismuth shield on reducing the radiation dose to the eye lens region during CT brain examination. Materials and methods: We conducted a series of phantom studies to measure the entrance surface dose (ESD) that is delivered to the eye lens region during CT brain examination under the effect of different scanning and shielding setups. Results: Our results indicated, during CT brain examination: (1) a drastic reduction of 92.5% in the ESD to the eye lens region was found when the CT gantry was tilted from 0 deg. (overall ESD = 30.7 mGy) to 30 deg. cranially (overall ESD = 2.4 mGy), and (2) when the CT gantry was positioned at 0 deg. (the common practice in the clinical setting), the setups with the application of a) a bismuth shield, b) a bismuth shield with a face shield (air gap), c) a bismuth shield with bolus, and d) a bismuth shield with bolus and an air gap can result in an acceptable level of image quality with a smaller overall ESD delivered to the eye lens region (overall ESD = 23.2 mGy, 24 mGy, 21 mGy and 19.9 mGy, respectively) than the setup without the bismuth shield applied (overall ESD = 30.7 mGy). Conclusion: When the primary beam scanning through the eye lens region is unavoidable during CT brain examination, the combined use of a bismuth shield with bolus and a face shield is an easy-to-use and inexpensive shielding setup to reduce the radiation dose delivered to the eye lens region while

  11. Fat Injection: A Systematic Review of Injection Volumes by Facial Subunit.

    Science.gov (United States)

    Shue, Shirley; Kurlander, David E; Guyuron, Bahman

    2017-08-08

    Fat grafting to the aging face has become an integral component of esthetic surgery. However, the amount of fat to inject to each area of the face is not standardized and has been based mainly on the surgeon's experience. The purpose of this study was to perform a systematic review of injected fat volume to different facial zones. A systematic review of the literature was performed through a MEDLINE search using keywords "facial," "fat grafting," "lipofilling," "Coleman technique," "autologous fat transfer," and "structural fat grafting." Articles were then sorted by facial subunit and analyzed for: author(s), year of publication, study design, sample size, donor site, fat preparation technique, average and range of volume injected, time to follow-up, percentage of volume retention, and complications. Descriptive statistics were performed. Nineteen articles involving a total of 510 patients were included. Rhytidectomy was the most common procedure performed concurrently with fat injection. The mean volume of fat injected to the forehead is 6.5 mL (range 4.0-10.0 mL); to the glabellar region 1.4 mL (range 1.0-4.0 mL); to the temple 5.9 mL per side (range 2.0-10.0 mL); to the eyebrow 5.5 mL per side; to the upper eyelid 1.7 mL per side (range 1.5-2.5 mL); to the tear trough 0.65 mL per side (range 0.3-1.0 mL); to the infraorbital area (infraorbital rim to lower lid/cheek junction) 1.4 mL per side (range 0.9-3.0 mL); to the midface 1.4 mL per side (range 1.0-4.0 mL); to the nasolabial fold 2.8 mL per side (range 1.0-7.5 mL); to the mandibular area 11.5 mL per side (range 4.0-27.0 mL); and to the chin 6.7 mL (range 1.0-20.0 mL). Data on exactly how much fat to inject to each area of the face in facial fat grafting are currently limited and vary widely based on different methods and anatomical terms used. This review offers the ranges and the averages for the injected volume in each zone. This journal requires that authors assign a level of evidence

  12. Effects of different components of Mao Dongqing's total flavonoids and total saponins on transient ischemic attack (TIA) model of rats.

    Science.gov (United States)

    Miao, Ming-San; Peng, Meng-Fan; Ma, Rui-Juan; Bai, Ming; Liu, Bao-Song

    2018-03-01

    Objective: To study the effects of the different components of the total flavonoids and total saponins from Mao Dongqing's active site on the rats of TIA model, determine the optimal reactive components ratio of Mao Dongqing on the rats of TIA. Methods: TIA rat model was induced by tail vein injection of tert butyl alcohol, the blank group was injected with the same amount of physiological saline, then behavioral score wasevaluated. Determination the level of glutamic acid in serum, the activity of Na+-K+-ATP enzyme, CA ++ -ATP enzyme and Mg ++ -ATP enzyme in Brain tissue, observe the changes of hippocampus in brain tissue, the comprehensive weight method was used to evaluate the efficacy of each component finally. Results: The contents of total flavonoids and total saponins in the active part of Mao Dongqing can significantly improve the pathological changes of brain tissue in rats, improve the activity of Na + -K + -ATP enzyme, Ca ++ -ATP enzyme and Mg ++ -ATP enzyme in the brain of rats, and reduce the level of glutamic acid in serum. The most significant of the contents was the ratio of 10:6. The different proportions of total flavonoids and total saponins in the active part of Mao Dongqing all has a better effect on the rats with TIA, and the ratio of 10:6 is the best active component for preventing and controlling TIA.

  13. Study Protocol. ECSSIT – Elective Caesarean Section Syntocinon® Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon® 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section

    Directory of Open Access Journals (Sweden)

    Montgomery Alan A

    2009-08-01

    Full Text Available Abstract Background Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4–10 minutes therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. Methods and design A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml. A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. Discussion It is both important and timely that we evaluate the optimal approach to the management

  14. Study Protocol. ECSSIT – Elective Caesarean Section Syntocinon® Infusion Trial. A multi-centre randomised controlled trial of oxytocin (Syntocinon®) 5 IU bolus and placebo infusion versus oxytocin 5 IU bolus and 40 IU infusion for the control of blood loss at elective caesarean section

    Science.gov (United States)

    Murphy, Deirdre J; Carey, Michael; Montgomery, Alan A; Sheehan, Sharon R

    2009-01-01

    Background Caesarean section is one of the most commonly performed major operations in women throughout the world. Rates are escalating, with studies from the United States of America, the United Kingdom, China and the Republic of Ireland reporting rates between 20% and 25%. Operative morbidity includes haemorrhage, anaemia, blood transfusion and in severe cases, maternal death. The value of routine oxytocics in the third stage of vaginal birth has been well established and it has been assumed that these benefits apply to caesarean delivery as well. A slow bolus dose of oxytocin is recommended following delivery of the baby at caesarean section. Some clinicians use an additional infusion of oxytocin for a further period following the procedure. Intravenous oxytocin has a very short half-life (4–10 minutes) therefore the potential advantage of an oxytocin infusion is that it maintains uterine contractility throughout the surgical procedure and immediate postpartum period, when most primary haemorrhages occur. The few trials to date addressing the optimal approach to preventing haemorrhage at caesarean section have been under-powered to evaluate clinically important outcomes. There has been no trial to date comparing the use of an intravenous slow bolus of oxytocin versus an oxytocin bolus and infusion. Methods and design A multi-centre randomised controlled trial is proposed. The study will take place in five large maternity units in Ireland with collaboration between academics and clinicians in the disciplines of obstetrics and anaesthetics. It will involve 2000 women undergoing elective caesarean section after 36 weeks gestation. The main outcome measure will be major haemorrhage (blood loss >1000 ml). A study involving 2000 women will have 80% power to detect a 36% relative change in the risk of major haemorrhage with two-sided 5% alpha. Discussion It is both important and timely that we evaluate the optimal approach to the management of the third stage at

  15. Does growth hormone releasing factor desensitize the somatotroph? Interpretation of responses of growth hormone during and after 10-hour infusion of GRF 1-29 amide in man.

    Science.gov (United States)

    Davis, J R; Sheppard, M C; Shakespear, R A; Lynch, S S; Clayton, R N

    1986-02-01

    It is unclear whether growth hormone releasing factor (GRF) administration in vivo may desensitize the somatotroph. To investigate this possibility we have examined the effects of 10-h infusion of the equipotent 1-29 amide analogue of hpGRF on serum GH levels and on the subsequent GH response to a bolus dose of GRF (1-29). Four normal adult males received an intravenous infusion of 1-29 GRF (1 microgram/kg/h) from 0800 to 1800 h, with blood samples taken at 10 min intervals. A 100 micrograms intravenous bolus dose of GRF was given at 1800 h, and sampling continued for a further 90 min. GH levels were near or below the limit of detection (0.5 mU/l) throughout the control 10 h period. During GRF infusion there was increased GH release with pulses of irregular frequency and amplitude (up to 80 mU/l) continuing throughout the entire infusion period. There was no apparent reduction in total GH released towards the latter part of the infusion. On the control day, 100 micrograms GRF bolus increased mean (+/- SEM) GH from 0.82 +/- 0.21 mU/l to a peak of 59.0 +/- 44.8 mU/l (P less than 0.002). Following 10-GRF infusion, responses to bolus injection of GRF were reduced, but variable. In two subjects a small rise in GH levels occurred (basal 6.4 and 7.2 rising to peak values of 11.2 and 23.0 mU/l respectively). In the other two subjects, GH levels fell but in these the GRF bolus had coincided with a GH peak. The loss of GRF responsiveness after GRF infusion may be due to 'desensitization'.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  17. A randomized clinical trial on comparison of corticosteroid injection with or without splinting versus saline injection with or without splinting in patients with lateral epicondylitis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Tahririan

    2014-01-01

    Full Text Available Background: Lateral epicondylitis is a common problem affecting 1-3% of the population. There has been much debate about the best treatment modality for this condition. There is, however, no conclusive evidence in support of any of the proposed treatment modalities. In this trial, we have studied the effect of corticosteroid injection (with or without splinting with normal saline injection (with or without splinting. Materials and Methods: In this double-blind, randomized clinical trial, individuals were randomly assigned to either of four treatment groups and received either 40 mg depomedrol injection alone, 40 mg depomedrol injection with splinting, normal saline injection alone, or normal saline injection with splinting. They were evaluated using the visual analog scale (VAS at weeks 2, 4 and 24 and with the Oxford elbow scale (OES at 24 weeks. Results: A total of 79 patients were participated in the study. The corticosteroid injection groups had better pain relief as measured by VAS at 2 and 4 weeks compared with the two saline injection groups. Mean VAS difference at week 0 versus week 2 was 4.5 ± 0.9 and 2.8 ± 0.6 in corticosteroid injection groups and saline injection groups respectively (P < 0.01 but at 24 weeks, there was only moderate benefit reported for the group which received steroid injection and splinting (P < 0.01 compared to the saline injection groups. The saline injection groups reported better improvement in OES scores (20.1 ± 3.7 at the end of the trial compared corticosteroid injection groups (16.1 ± 2.9 (P < 0.05. Conclusion: Our results indicate that despite the clear pain reduction benefit associated with steroid injection in short term, this benefit in comparison with normal saline injection fades by the 24 th week of follow-up.

  18. The effects of repeated Ozurdex injections on ocular hypertension.

    Science.gov (United States)

    Bahadorani, Sepehr; Krambeer, Chelsey; Wannamaker, Kendall; Tie, Wayne; Jansen, Michael; Espitia, Jason; Sohn, Jeong-Hyeon; Singer, Michael A

    2018-01-01

    The purpose of this study was to correlate the degree of ocular hypertension with the number of Ozurdex injections. Intraocular pressure (IOP) fluctuations for a total of 183 injections were studied over a period of at least 12 months. The main indications for treatment were uveitis, diabetic macular edema, and retinal vein occlusion. Results of the study demonstrate that repeated Ozurdex injections do not increase the frequency of IOP spikes beyond 30 mmHg. For lower IOPs, however, a positive correlation exists. Furthermore, patients with primary open angle glaucoma and uveitis had the highest IOP response to repeated injections. On average, patients with an IOP of ≥28.6 mmHg received pressure lowering medications, after which their IOP reached a stable level (16.7 mmHg) without the need for additional interventions. The data support the conclusion that multiple Ozurdex injections does not increase the frequency of IOP spikes beyond 30 mmHg, but patients still must be closely monitored if they have a history of primary open angle glaucoma.

  19. The Efficacy of Liposomal Bupivacaine Using Periarticular Injection in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Kuang, Ming-Jie; Du, Yuren; Ma, Jian-Xiong; He, Weiwei; Fu, Lin; Ma, Xin-Long

    2017-04-01

    Total knee arthroplasty (TKA) is gradually emerging as the treatment of choice for end-stage osteoarthritis. In the past, the method of liposomal bupivacaine by periarticular injection (PAI) showed better effects on pain reduction and opioid consumption after surgery. However, some recent studies have reported that liposomal bupivacaine by PAI did not improve pain control and functional recovery in patients undergoing TKA. Therefore, this meta-analysis was conducted to determine whether liposomal bupivacaine provides better pain relief and functional recovery after TKA. Web of Science, PubMed, Embase, and the Cochrane Library were comprehensively searched. Randomized controlled trials, controlled clinical trials, and cohort studies were included in our meta-analysis. Eleven studies that compared liposomal bupivacaine using the PAI technique with the conventional PAI method were included in our meta-analysis. The preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines and Cochrane Handbook were applied to assess the quality of the results published in all included studies to ensure that the results of our meta-analysis were reliable and veritable. Our pooled data analysis demonstrated that liposomal bupivacaine was as effective as the control group in terms of visual analog scale score at 24 hours (P = .46), 48 hours (P = .43), 72 hours (P = .21), total amount of opioid consumption (P = .25), range of motion (P = .28), length of hospital stay (P = .53), postoperative nausea (P = .34), and ambulation distance (P = .07). Compared with the conventional PAI method, liposomal bupivacaine shows similar pain control and functional recovery after TKA. Considering the cost for pain control, liposomal bupivacaine is not worthy of being recommended as a long-acting alternative analgesic agent using the PAI method. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. MKI UFOs at Injection

    CERN Document Server

    Baer, T; Bartmann, W; Bracco, C; Carlier, E; Chanavat, C; Drosdal, L; Garrel, N; Goddard, B; Kain, V; Mertens, V; Uythoven, J; Wenninger, J; Zerlauth, M

    2011-01-01

    During the MD, the production mechanism of UFOs at the injection kicker magnets (MKIs) was studied. This was done by pulsing the MKIs on a gap in the circulating beam, which led to an increased number of UFOs. In total 43 UFO type beam loss patterns at the MKIs were observed during the MD. The MD showed that pulsing the MKIs directly induces UFO type beam loss patterns. From the temporal characteristics of the loss profile, estimations about the dynamics of the UFOs are made.

  1. Curative effect of monosialotetrahexosylganglioside combined with Xingnaojing injection on acute cerebral hemorrhage

    Directory of Open Access Journals (Sweden)

    Rui-xing SUN

    2015-07-01

    Full Text Available This paper aims to observe the curative effect of monosialotetrahexosylganglioside combined with Xingnaojing injection on acute cerebral hemorrhage. A total of 120 cases with acute cerebral hemorrhage were treated with Xingnaojing injection monotherapy (control group, N = 60 or monosialotetrahexosylganglioside combined with Xingnaojing injection (combined treatment group, N = 60. Bleeding amount and National Institutes of Health Stroke Scale (NIHSS scores of 2 groups were both significantly reduced on the 21th day after treatment (P = 0.000, for all, but bleeding amount and NIHSS scores in combined treatment group were significantly lower than those in control group (P = 0.000, for all. After 21 d treatment, total effective rate of combined treatment group was 86.67% (52/60, which was significantly higher than that of control group [66.67% (40/60; χ2 = 1.493, P = 0.024]. For patients with acute cerebral hemorrhage, monosialotetrahexosylganglioside combined with Xingnaojing injection can significantly improve the neurological function. DOI: 10.3969/j.issn.1672-6731.2015.07.014

  2. Hydrodynamics of Safety Injection Tank with Fluidic Device in Recent Regulation

    International Nuclear Information System (INIS)

    Bang, Young Seok; Yoo, Seung Hun

    2016-01-01

    Safety Injection Tank (SIT) with Fluidic Device (FD) has been used in several APR1400 nuclear power plants. It was designed to provide a longer passive safety injection than the existing accumulator to improve the safety for Large Break Loss-of-Coolant Accident (LBLOCA) by changing the injected flow through the FD and the standpipe of the SIT. As a result, high flow injection phase and the subsequent low flow one can be achieved as longer than the existing accumulator. The present paper discusses the major concerns related to SIT hydrodynamics and the directions to resolution recently concerned. Modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing are included. Based on the discussion, a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The present paper discussed the SIT hydrodynamics including the modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing. Also a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The following conclusions are obtained uncertainty due to the assumption of the total Kfactor as constant for high flow, transition phase, and low flow phase should be considered and nitrogen intrusion phenomena during the transition phase should be considered with a conservatism, especially considering the current situation of nonmeasuring the standpipe level

  3. Hydrodynamics of Safety Injection Tank with Fluidic Device in Recent Regulation

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Young Seok; Yoo, Seung Hun [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    Safety Injection Tank (SIT) with Fluidic Device (FD) has been used in several APR1400 nuclear power plants. It was designed to provide a longer passive safety injection than the existing accumulator to improve the safety for Large Break Loss-of-Coolant Accident (LBLOCA) by changing the injected flow through the FD and the standpipe of the SIT. As a result, high flow injection phase and the subsequent low flow one can be achieved as longer than the existing accumulator. The present paper discusses the major concerns related to SIT hydrodynamics and the directions to resolution recently concerned. Modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing are included. Based on the discussion, a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The present paper discussed the SIT hydrodynamics including the modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing. Also a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The following conclusions are obtained uncertainty due to the assumption of the total Kfactor as constant for high flow, transition phase, and low flow phase should be considered and nitrogen intrusion phenomena during the transition phase should be considered with a conservatism, especially considering the current situation of nonmeasuring the standpipe level.

  4. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  5. In-vitro and in-vivo evaluation of diclofenac sodium intramuscular injection using gamma scintigraphy

    International Nuclear Information System (INIS)

    Soni, S.; Kumar, N.; Mehra, L.; Singh, T.; Mittal, G.; Nishad, D.K.; Sharma, B.G.; Bhatnagar, A.

    2010-01-01

    Full text: Diclofenac is a non-steroidal anti-inflammatory drug (NSAID) which is available as over-the-counter (OTC) medication for the systemic and topical treatment of painful and inflammatory conditions such as arthritis and back pain. This study was undertaken to investigate the distribution and retention of intramuscularly injected diclofenac sodium (DFN) in white New Zealand rabbit using gamma scintigraphy. A new formulation of the nonselective NSAID diclofenac sodium suitable for intramuscular injection has been developed using sesame oil as a vehicle. The hypothesis of present work is to maintain effective concentration of DFN in blood for prolonged time period. A novel method of radiolabeling with 99m Tc-pertechnetate was adopted using stannous ions as reducing agent. The radiolabeled product was tested for quality control using ascending instant thin layer chromatography (ITLC) technique. ITLC-SG, (Gelman, USA) and acetone were used as the stationary phase and mobile phase respectively in the chromatographic procedure. In vitro and in vivo stability parameters were evaluated. Biodistribution studies and blood kinetics of 99m Tc-DFN was done in balb c mice and white New Zealand rabbit respectively. 99m Tc-DFN retention at depot site was evaluated using gamma scintigraphy. 99m Tc-DFN, when incubated at 37 deg C for 24 hr in normal saline and human serum showed disintegration of only 6.6% and 3.5% respectively, thereby indicating high stability of radiolabeled product. Protein binding studies of 99m Tc-DFN shows more than 85% serum protein binding. Blood clearance of radiopharmaceutical in rabbits, exhibited a biphasic exponential pattern in i.v. bolus while in i.m. linear control release pattern were observed up to 24 hrs

  6. Design of the ESCAR injection beam line

    International Nuclear Information System (INIS)

    Tanabe, J.; Staples, J.; Yourd, R.

    1975-01-01

    The design features of the elements of the ESCAR (Experimental Superconducting Accelerator Ring) injection beam line are described. The junction of the proton transport system with the ESCAR injection straight section requires the design of mechanical elements compatible with the 10 -11 torr vacuum requirements of the main ring. These elements include a novel septum magnet whose salient design features include a current-carrying septum of tapered thicknesses to reduce the overall power requirements and total enclosure of the magnet coil in a metal can for vacuum compatibility. Other elements are a wire electro-static septum and several fast-rise ''bump magnets''. A transition cryopump is designed to separate the main ring vacuum from the relatively poor 10 -6 torr vacuum of the conventional beam transport line. A brief description of the conventional beam transport line from the 50 MeV proton linac, recently installed for Bevatron injection,is also included. (U.S.)

  7. Modelling of injection processes in ladle metallurgy

    NARCIS (Netherlands)

    Visser, H.

    2016-01-01

    Ladle metallurgical processes constitute a portion of the total production chain of steel from iron ore. With these batch processes, the hot metal or steel transfer ladle is being used as a reactor vessel and a reagent is often injected in order to bring the composition of the hot metal or steel to

  8. Immunosuppression by fractionated total lymphoid irradiation in collagen arthritis

    International Nuclear Information System (INIS)

    McCune, W.J.; Buckley, J.A.; Belli, J.A.; Trentham, D.E.

    1982-01-01

    Treatments with fractionated total lymphoid irradiation (TLI) and cyclophosphamide were evaluated for rats injected with type II collagen. Preadministration of TLI and repeated injections of cyclophosphamide suppressed the severity of arthritis and lowered antibody titers to collagen significantly. TLI initiated at the onset of collagen arthritis decreased humoral and cellular responses to collagen but did not affect the severity of arthritis. These data demonstrate that both TLi and cyclophosphamide are immunosuppressive in an experimentally inducible autoimmune disease

  9. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  10. Mitigating the Effects of Xuebijing Injection on Hematopoietic Cell Injury Induced by Total Body Irradiation with γ rays by Decreasing Reactive Oxygen Species Levels

    Directory of Open Access Journals (Sweden)

    Deguan Li

    2014-06-01

    Full Text Available Hematopoietic injury is the most common side effect of radiotherapy. However, the methods available for the mitigating of radiation injury remain limited. Xuebijing injection (XBJ is a traditional Chinese medicine used to treat sepsis in the clinic. In this study, we investigated the effects of XBJ on the survival rate in mice with hematopoietic injury induced by γ ray ionizing radiation (IR. Mice were intraperitoneally injected with XBJ daily for seven days after total body irradiation (TBI. Our results showed that XBJ (0.4 mL/kg significantly increased 30-day survival rates in mice exposed to 7.5 Gy TBI. This effect may be attributable to improved preservation of white blood cells (WBCs and hematopoietic cells, given that bone marrow (BM cells from XBJ-treated mice produced more granulocyte-macrophage colony forming units (CFU-GM than that in the 2 Gy/TBI group. XBJ also decreased the levels of reactive oxygen species (ROS by increasing glutathione (GSH and superoxide dismutase (SOD levels in serum and attenuated the increased BM cell apoptosis caused by 2 Gy/TBI. In conclusion, these findings suggest that XBJ enhances the survival rate of irradiated mice and attenuates the effects of radiation on hematopoietic injury by decreasing ROS production in BM cells, indicating that XBJ may be a promising therapeutic candidate for reducing hematopoietic radiation injury.

  11. A qualitative feasibility study to inform a randomised controlled trial of fluid bolus therapy in septic shock.

    Science.gov (United States)

    O'Hara, Caitlin B; Canter, Ruth R; Mouncey, Paul R; Carter, Anjali; Jones, Nicola; Nadel, Simon; Peters, Mark J; Lyttle, Mark D; Harrison, David A; Rowan, Kathryn M; Inwald, David; Woolfall, Kerry

    2018-01-01

    The Fluids in Shock (FiSh) Trial proposes to evaluate whether restrictive fluid bolus therapy (10 mL/kg) is more beneficial than current recommended practice (20 mL/kg) in the resuscitation of children with septic shock in the UK. This qualitative feasibility study aimed to explore acceptability of the FiSh Trial, including research without prior consent (RWPC), potential barriers to recruitment and participant information for a pilot trial. Qualitative interview study involving parents of children who had presented to a UK emergency department or been admitted to a paediatric intensive care unit with severe infection in the previous 3 years. Twenty-one parents (seven bereaved) were interviewed 16 (median) months since their child's hospital admission (range: 1-41). All parents said they would have provided consent for the use of their child's data in the FiSh Trial. The majority were unfamiliar with RWPC, yet supported its use. Parents were initially concerned about the change from currently recommended treatment, yet were reassured by explanations of the current evidence base, fluid bolus therapy and monitoring procedures. Parents made recommendations about the timing of the research discussion and content of participant information. Bereaved parents stated that recruiters should not discuss research immediately after a child's death, but supported a personalised postal 'opt-out' approach to consent. Findings show that parents whose child has experienced severe infection supported the proposed FiSh Trial, including the use of RWPC. Parents' views informed the development of the pilot trial protocol and site staff training. ISRCTN15244462-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Why do elephants flap their ears?

    African Journals Online (AJOL)

    metronome. A bolus of 40/0 Evans blue (T1824) was injected into the artery and venous collection continued for 30 tubes. About 0,7 ml dye solution was injected; the actual quantity being detennined by weighing the syringe. due allowance being made for the dead space. After centrifugation of the venous samples the dye ...

  13. Safety of bilateral same-day intravitreal injections of anti-vascular endothelial growth factor agents

    Directory of Open Access Journals (Sweden)

    Ruão M

    2017-02-01

    Full Text Available Miguel Ruão,1 María Andreu-Fenoll,2 Rosa Dolz-Marco,2 Roberto Gallego-Pinazo2 1Department of Ophthalmology, Centro Hospitalar Entre Douro e Vouga, Santa Maria da Feira, Portugal; 2Unit of Macula, Department of Ophthalmology, University and Polytechnic Hospital La Fe, Valencia, Spain Purpose: The aim was to evaluate the safety of bilateral same-day injections with intravitreal antiangiogenic drugs for macular diseases.Methods: Cross-sectional retrospective review of unilateral and bilateral same-day antiangiogenic injections was conducted between January 2011 and March 2016 in the Unit of Macula, University and Polytechnic Hospital La Fe (Valencia, Spain. A total of 8,172 injections were administered, among which 6,560 were unilateral and 1,612 were bilateral injections. Patients were included in the study regardless of the diagnosis. Ranibizumab and aflibercept were the antiangiogenic drugs used. The presence of endophthalmitis or retinal detachment was evaluated.Results: A total of 1 (0.012% culture-proven endophthalmitis and 19 (0.233% acute intraocular inflammations were registered. In the unilateral injections group, there were 18 (0.274% acute intraocular inflammations and 1 (0.015% culture-proven endophthalmitis. One (0.062% of the 1,612 bilateral same-day injections had a unilateral acute intraocular inflammation, and there were no culture-proven endophthalmitis in this group.Conclusion: Bilateral same-day injections are more convenient for patients and their caregivers than the unilateral injections administered on different days. In our study, the prevalence of culture-proven endophthalmitis and acute intraocular inflammation was lower in the bilateral injections than in the unilateral group. These data support the idea that bilateral same-day injections are a safe and valid treatment to use in our clinical practice. Keywords: bilateral, intravitreal, injections, anti-VEGF, endophthalmitis

  14. Assessment of MRI Contrast Agent Kinetics via Retro-Orbital Injection in Mice: Comparison with Tail Vein Injection.

    Science.gov (United States)

    Wang, Fang; Nojima, Masanori; Inoue, Yusuke; Ohtomo, Kuni; Kiryu, Shigeru

    2015-01-01

    It is not known whether administration of contrast agent via retro-orbital injection or the tail vein route affects the efficiency of dynamic contrast-enhanced magnetic resonance imaging (MRI). Therefore, we compared the effects of retro-orbital and tail vein injection on the kinetics of the contrast agent used for MRI in mice. The same group of nine healthy female mice received contrast agent via either route. An extracellular contrast agent was infused via the tail vein and retro-orbital vein, in random order. Dynamic contrast-enhanced MRI was performed before and after administering the contrast agent. The contrast effects in the liver, kidney, lung, and myocardium were assessed. The average total times of venous puncture and mounting of the injection system were about 10 and 4 min for the tail vein and retro-orbital route, respectively. For all organs assessed, the maximum contrast ratio occurred 30 s after administration and the time course of the contrast ratio was similar with either routes. For each organ, the contrast ratios correlated strongly; the contrast ratios were similar. The retro-orbital and tail vein routes afforded similar results in terms of the kinetics of the contrast agent. The retro-orbital route can be used as a simple efficient alternative to tail vein injection for dynamic contrast-enhanced MRI of mice.

  15. Flow-injection determination of total organic fluorine with off-line defluorination reaction on a solid sorbent bed.

    Science.gov (United States)

    Musijowski, Jacek; Trojanowicz, Marek; Szostek, Bogdan; da Costa Lima, José Luis Fontes; Lapa, Rui; Yamashita, Hiroki; Takayanagi, Toshio; Motomizu, Shoji

    2007-09-26

    Considering recent reports on widespread occurrence and concerns about perfluoroalkyl substances (PFAS) in environmental and biological systems, analysis of these compounds have gained much attention in recent years. Majority of analyte-specific methods are based on a LC/MS/MS or a GC/MS detection, however many environmental or biological studies would benefit from a total organic fluorine (TOF) determination. Presented work was aimed at developing a method for TOF determination. TOF is determined as an amount of inorganic fluoride obtained after defluorination reaction conducted off-line using sodium biphenyl reagent directly on the sorbent without elution of retained analytes. Recovered fluoride was analyzed using flow-injection system with either fluorimetric or potentiometric detection. The TOF method was tested using perfluorocarboxylic acids (PFCA), including perfluorooctanoic acid (PFOA), as model compounds. Considering low concentrations of PFAS in natural samples, solid-phase extraction as a preconcentration procedure was evaluated. Several carbon-based sorbents were tested, namely multi-wall carbon nanotubes, carbon nanofibres and activated carbon. Good sorption of all analytes was achieved and defluorination reaction was possible to carry out directly on a sorbent bed. Recoveries obtained for PFCAs, adsorbed on an activated carbon sorbent, and measured as TOF, were 99.5+/-1.7, 110+/-9.4, 95+/-26, 120+/-32, 110+/-12 for C4, C6, C8, C10 and C12-PFCA, respectively. Two flow systems that would enable the defluorination reaction and fluoride determination in a single system were designed and tested.

  16. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  17. Intracoronary versus Intravenous eptifibatide during percutaneous coronary intervention for acute ST-segment elevation myocardial infarction; a randomized controlled trial.

    Science.gov (United States)

    Sanati, Hamid Reza; Zahedmehr, Ali; Firouzi, Ata; Farrashi, Melody; Amin, Kamyar; Peighambari, Mohammad Mehdi; Shakerian, Farshad; Kiani, Reza

    2017-10-01

    Although aspirin and clopidogrel seem to be quite enough during low risk percutaneous coronary intervention (PCI), the combination may need some reinforcement in complex situations such as primary PCI. By modifying the route and also the duration of administration, glycoprotein IIb/IIIa inhibitors might be a viable option. The aim of this study is to compare the benefits and disadvantages of three different methods of administration of eptifibatide in primary PCI population. Primary PCI candidates were randomized in three groups on which three different methods of administration of eptifibitide were tested: intravenous bolus injection followed by 12-h infusion (IV-IV), intracoronary bolus injection followed by intravenous infusion (IC-IV) and, only intracoronary bolus injection (IC). 99 patients were included in the present study. There was no significant difference among the three groups regarding all cause in hospital and one month mortality (p value = 0.99), re-myocardial infarction (p value = 0.89), post-PCI TIMI flow grade 3 (p value = 0.97), ST segment resolution (p value = 0.77) and peak troponin levels (p value = 0.82). The comparison of vascular access and major bleeding complications were not possible due to low events rate. By modifying the route of administration of eptifibitide, the clinical effect might be preserved without increasing the short-term mortality and procedural failure.

  18. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  19. Energetic ion diagnostics using neutron flux measurements during pellet injection

    International Nuclear Information System (INIS)

    Heidbrink, W.W.

    1986-01-01

    Neutron measurements during injection of deuterium pellets into deuterium plasmas on the Tokamak Fusion Test Reactor (TFTR) indicate that the fractional increase in neutron emission about 0.5 msec after pellet injection is proportional to the fraction of beam-plasma reactions to total fusion reactions in the unperturbed plasma. These observations suggest three diagnostic applications of neutron measurements during pellet injection: (1) measurement of the beam-plasma reaction rate in deuterium plasmas for use in determining the fusion Q in an equivalent deuterium-tritium plasma, (2) measurement of the radial profile of energetic beam ions by varying the pellet size and velocity, and (3) measurement of the ''temperature'' of ions accelerated during wave heating. 18 refs., 3 figs

  20. Activity and toxicity of oxaliplatin and bolus fluorouracil plus leucovorin in pretreated colorectal cancer patients: a phase 2. study

    Energy Technology Data Exchange (ETDEWEB)

    Ferraresi, V.; Buccilli, A.; Giannarelli, D.; Ciccarese, M. [Regina Elena Cancer Institute, Rome (Italy). Dept. of Medical Oncology; Giampaolo, M.A.; Gabriele, A.; Buccilli, A.; Gamucci, T. [Azienda Sanitaria Locale, Frosinone (Italy). Complex Operative Unit of Medical Oncology

    2005-06-15

    The aim of the current study was to evaluate the activity and toxicity of a combination of oxaliplatin with bolus fluorouracil and leucovorin in colorectal cancer (CRC) patients pretreated for advanced disease with various schedules including continuous fluorouracil infusion. Thirty consecutive patients with pretreated advanced CRC received oxaliplatin 130 mg/m{sup 2} by 2-h infusion dl, leucovorin 100 mg/m{sup 2} by 1-h infusion followed by fluorouracil 425 mg/m{sup 2} i.v. bolus from day 1 to 3 every 3 weeks for a maximum of 6 cycles. The best overall response rate in an intent-to-treat analysis was 13% (2 complete responses and 2 partial responses) (95% CI, 1.2-25.5%) and 37% of patients obtained stable disease with a tumor growth control rate of 50% (95% CI, 32.1-67.9%). The median progression-free survival was 4.0 months (95% CI, 1.4-6.5 months) and median overall survival was 12.0 months (95% CI, 9.9-14.1 months). The independent prognostic factors for improved overall survival were a good performance status and a response/stabilization of disease to chemotherapy. Severe neutropenia was quite common (43.3% of patients and 14.4% of cycles), although complicated by fever only in one case (3.3% of patients). There was one toxic death. In conclusion, the study combination showed an interesting rate of tumor growth control in a cohort of patients previously treated for advanced disease with various schedules including continuous fluorouracil infusion.