WorldWideScience

Sample records for total body x-ray

  1. Dosimetry for total body irradiation of rhesus monkeys with 300 kV X- rays

    NARCIS (Netherlands)

    Zoetelief, J.; Wagemaker, G.; Broerse, J.J.

    1998-01-01

    Purpose: To obtain more accurate information on the dose distribution in rhesus monkeys for total body irradiation with orthovoltage X-rays. Materials and methods: Dose measurements were performed with an ionization chamber inside homogeneous cylindrical and rectangular phantoms of various

  2. The influence of x-ray energy on lung dose uniformity in total-body irradiation

    International Nuclear Information System (INIS)

    Ekstrand, Kenneth; Greven, Kathryn; Wu Qingrong

    1997-01-01

    Purpose: In this study we examine the influence of x-ray energy on the uniformity of the dose within the lung in total-body irradiation treatments in which partial transmission blocks are used to control the lung dose. Methods and Materials: A solid water phantom with a cork insert to simulate a lung was irradiated by x-rays with energies of either 6, 10, or 18 MV. The source to phantom distance was 3.9 meters. The cork insert was either 10 cm wide or 6 cm wide. Partial transmission blocks with transmission factors of 50% were placed anterior to the cork insert. The blocks were either 8 or 4 cm in width. Kodak XV-2 film was placed in the midline of the phantom to record the dose. Midplane dose profiles were measured with a densitometer. Results: For the 10 cm wide cork insert the uniformity of the dose over 80% of the block width varied from 6.6% for the 6 MV x-rays to 12.2% for the 18 MV x-rays. For the 6 cm wide cork insert the uniformity was comparable for all three x-ray energies, but for 18 MV the central dose increased by 9.4% compared to the 10 cm wide insert. Conclusion: Many factors must be considered in optimizing the dose for total-body irradiation. This study suggests that for AP/PA techniques lung dose uniformity is superior with 6 MV irradiation. The blanket recommendation that the highest x-ray energy be used in TBI is not valid for all situations

  3. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu...

  4. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.

    1987-01-01

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs [de

  5. The nuclear pore density in rat liver cells upon regeneration and total body X-ray irradiation

    International Nuclear Information System (INIS)

    Kuz'mina, S.N.; Troitskaya, L.P.; Mirkhamidova, P.A.; Bul'dyaeva, T.V.; Zbarskij, I.B.; Grigor'ev, V.B.; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Virusologii)

    1979-01-01

    The nuclear pore density has been investigated in rat liver cells in the course of regeneration and X-ray irradiation. It has been found that the number of pore complexes (PC) per nuclear shell (NS) unit area in the liver cells is not constant. In an hour following whole-body irradiation of rats with a regenerating liver at the 1200 R dose the number of PC per 1 μm 2 of the nuclear shell area decreases by 5, 8 times as compared with the PC density in the regenerating liver cells of the irradiated rats, the PC degradation and structural rupture being observed. It has been established by means of the freezing-etching method which enables PC surfaces observation as for cytoplasma as well as for nucleoplasma that the PC peripheral granulas and the central granula consist of subparticles being approximately of the same size. The central granula forms a channel through which the material containing RNA passes from the nucleus to the cytoplasma. On the basis of the fact that the treatement by Triton X-100, disarranging the integrity of the NS membranous structure, preserves PC in relation to the fibrous layer as well as on the basis of the unequal nuclear pore state observed on the platinum-carbon replicas from nuclei splits it is supposed that PC can be formed in the nucleus and then in the course of repening ''built in'' PS

  6. Change in fat-free mass assessed by bioelectrical impedance, total body potassium and dual energy X-ray absorptiometry during prolonged weight loss

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Højgaard, L

    1996-01-01

    A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK). These measu......A total of 16 obese women (body mass index (BMI) 30-43 kg m(-2)) participated in a weight reduction study. Before and after a weight loss of 11.7 +/- 7.4 kg (mean +/- SD), body composition was assessed by dual energy X-ray absorptiometry (DXA), and total body potassium counting (TBK......). These measurements were compared with bioimpedance analysis (BIA) by applying 11 predictive BIA equations published in the literature. Predictive equations for the present study population were developed, with the use of fat-free mass (FFM) as assessed by TBK and DXA as references in multiple regression analysis....... The results of the BIA equations varied widely; FFM was generally overestimated by BIA as compared with DXA and TBK before and after weight loss. During weight loss, the FFM did not change, as estimated by DXA (1.3 +/- 2.3 kg, p > 0.05) and TBK (0.9 +/- 2.9 kg, p > 0.05). The recorded change in impedance (R...

  7. Total and Segmental Body Composition Examination in Collegiate Football Players Using Multifrequency Bioelectrical Impedance Analysis and Dual X-ray Absorptiometry.

    Science.gov (United States)

    Raymond, Christiana J; Dengel, Donald R; Bosch, Tyler A

    2018-03-01

    Raymond, CJ, Dengel, DR, and Bosch, TA. Total and segmental body composition examination in collegiate football players using multifrequency bioelectrical impedance analysis and dual X-ray absorptiometry. J Strength Cond Res 32(3): 772-782, 2018-The current study examined the influence of player position on the agreement between multifrequency bioelectrical impedance analysis (MfBIA) and dual X-ray absorptiometry (DXA) when assessing total and segmental percent body fat (BF%), fat mass (FM), and fat-free mass (FFM) in National Collegiate Athletic Association Division I collegiate football athletes. Forty-four male collegiate athletes (age = 19 ± 1 year; height = 1.9 ± 1.0 m; and body mass = 106.4 ± 18.8 kg) participated. Player positions included: offensive linemen (OL; n = 7), tight ends (TE; n = 4), wide receivers (WR; n = 9), defensive linemen (DL; n = 6), defensive backs (DB; n = 8), linebackers (LB; n = 6), and running backs (RB; n = 4). Total and segmental body composition measured using MfBIA were compared with values obtained using DXA. Compared with DXA, MfBIA underestimated BF% (3.0 ± 3.8%), total FM (2.5 ± 4.3 kg), arm FM (0.4 ± 0.8 kg), arm FFM (1.4 ± 0.9 kg), leg FM (2.8 ± 2.0 kg), and leg FFM (5.4 ± 2.4 kg) (all p FFM (-2.4 ± 4.5 kg) (p FFM), ±3.83 kg (leg FM), ±4.62 kg (leg FFM), and ±8.83 kg (total FFM). No significant differences were observed between devices for trunk FM (-0.3 ± 3.0 kg; p = 0.565) and trunk FFM (0.4 ± 2.4 kg; p = 0.278), with LOAs of ±5.92 and ±4.69 kg, respectively. Player position significantly affected all between-device mean body composition measurement differences (adjusted p ≤ 0.05), with OL demonstrating the greatest effect on each variable. Therefore, MfBIA does not seem accurate in examining between-player body composition in college football players.

  8. Characterization of changes in total body composition for patients with head and neck cancer undergoing chemoradiotherapy using dual-energy x-ray absorptiometry.

    Science.gov (United States)

    Jackson, William; Alexander, Neil; Schipper, Matthew; Fig, Lorraine; Feng, Felix; Jolly, Shruti

    2014-09-01

    Patients with head and neck cancer experience significant weight loss secondary to concurrent chemoradiotherapy (CCRT). Using dual-energy X-ray absorptiometry (DEXA) scans, we characterize total body composition changes during and after CCRT in order to develop novel clinical care models that will improve the patient's quality of life (QOL). Sixty DEXA scans were obtained from 12 patients undergoing CCRT for locally advanced squamous cell head and neck cancer. DEXAs were performed at baseline, during treatment, completion of CCRT, and then 1 and 2 months posttreatment. Mean weight loss by treatment end was 9.5 kg (10.2%; p = .0002). On average, lean body mass (LBM) decreased 10.2% (p = .001), and fat body mass (FBM) decreased 11.1% (p = .001) during CCRT. LBM began to normalize after completion of treatment, whereas FBM continued to decline. Substantial loss of muscle and FBM occurs in patients undergoing CCRT for head and neck cancer. To prevent long-term disability and QOL decline after curative CCRT, clinical care interventions incorporating aggressive nutrition/exercise counseling are needed. Copyright © 2013 Wiley Periodicals, Inc.

  9. Associations Between Sedentary Time, Physical Activity, and Dual-Energy X-ray Absorptiometry Measures of Total Body, Android, and Gynoid Fat Mass in Children.

    Science.gov (United States)

    McCormack, Lacey; Meendering, Jessica; Specker, Bonny; Binkley, Teresa

    2016-01-01

    Negative health outcomes are associated with excess body fat, low levels of physical activity (PA), and high sedentary time (ST). Relationships between PA, ST, and body fat distribution, including android and gynoid fat, assessed using dual-energy X-ray absorptiometry (DXA) have not been measured in children. The purpose of this study was to test associations between levels of activity and body composition in children and to evaluate if levels of activity predict body composition by DXA and by body mass index percentile in a similar manner. PA, ST, and body composition from 87 children (8.8-11.8 yr, grades 3-5, 44 boys) were used to test the association among study variables. Accelerometers measured PA and ST. Body composition measured by DXA included bone mineral content (BMC) and fat and lean mass of the total body (TB, less head), android, and gynoid regions. ST (range: 409-685 min/wk) was positively associated with TB percent fat (0.03, 95% confidence interval [CI]: 0.00-0.05) and android fat mass (1.5 g, 95% CI: 0.4-3.0), and inversely associated with the lean mass of the TB (-10.7 g, 95% CI: -20.8 to -0.63) and gynoid regions (-2.2 g, 95% CI: -4.3 to -0.2), and with BMC (-0.43 g, 95% CI: 0.77-0.09). Moderate-to-vigorous PA was associated with lower TB (-53 g, 95% CI: -87 to -18), android (-5 g, 95% CI: -8 to -2]), and gynoid fat (-6 g, 95% CI: -11 to -0.5). Vigorous activity results were similar. Light PA was associated with increased TB (17.1 g, 95% CI: 3.0-31.3) and gynoid lean mass (3.9 g, 95% CI: 1.0-6.8) and BMC (0.59 g, 95% CI: 0.10-1.07). In boys, there were significant associations between activity and DXA percent body fat measures that were not found with the body mass index percentile. Objective measures of PA were inversely associated with TB, android, and gynoid fat, whereas ST was directly associated with TB percent fat and, in particular, android fat. Activity levels predict body composition measures by DXA and, in

  10. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Sakurai, K.; Eba, H.; Numako, C.; Suzuki, M.; Inoue, K.; Yagi, N.

    2000-01-01

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  11. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    Applicability of total reflection X-ray fluorescence (TXRF) spectrometry for trace elemental analysis of rainwater samples was studied. The study was used to develop these samples as rainwater standards by the National University of Singapore (NUS). Our laboratory was one of the participants to use TXRF for this study.

  12. Body composition during weight loss in obese patients estimated by dual energy X-ray absorptiometry and by total body potassium

    DEFF Research Database (Denmark)

    Hendel, H W; Gotfredsen, A; Andersen, T

    1996-01-01

    for FFM were strong (r = 0.92 and 0.93). Bland and Altman plots showed limits of agreement of +/-9 kg before and after weight loss; DXA underestimated FFM in women and overestimated FFM in men. DXA accounted for 80% of the lost body weight. The composition of the lost body mass did not differ from...... that estimated by TBK (7.6% FFM and 92.4% FM by TBK; 11% FFM and 89% FM by DXA). CONCLUSION: DXA estimates accurately the body composition and the composition of weight loss in groups of obese subjects. However, the scan table may be too small for patients weighing more than 95 kg....

  13. Total reflection X-ray photoelectron spectroscopy: A review

    International Nuclear Information System (INIS)

    Kawai, Jun

    2010-01-01

    Total reflection X-ray photoelectron spectroscopy (TRXPS) is reviewed and all the published papers on TRXPS until the end of 2009 are included. Special emphasis is on the historical development. Applications are also described for each report. The background reduction is the most important effect of total reflection, but interference effect, relation to inelastic mean free path, change of probing depth are also discussed.

  14. X-ray body scanner for computerised tomography

    International Nuclear Information System (INIS)

    1977-01-01

    An X-ray source is described whose source is collimated into a thin fan-shaped beam. The detector means is spaced from the sources and both are mounted for scanning and orbiting jointly about a body in a partial or complete resolution. The X-ray intensities thus obtained provide data for reconstructing an image. The detector and source combination and the body are moved relative to one another in an axial direction to enable scanning of the body layers in sequence. In one embodiment the X-ray source is pulsed as it scans, and in another the fan-shaped beam is on continuously and readout is done sequentially. Thus in either case a large number of intensities for each layer are obtained. A high precision encoder system is used to synchronize X-ray pulses and readouts spatially and with line frequency. Means are provided for storing the cables leading to the rotatable source, the detectors and other moveable components. An embodiment for scanning a body part such as a breast has means for conditioning and controlling the water in which the part is immersed. (C.F.)

  15. X-ray inspection of foreign bodies in foods

    International Nuclear Information System (INIS)

    Ohira, Norihiro; Hongjun, Zhou; Sakamaki, Kazumi; Kamimura, Kunio; Shimizu, Hideaki; Saiki, Hideo

    2008-01-01

    X-ray inspection system of foreign bodies in foods has become is necessary for our society in recent years, with the expectation that they could inspect not only metals but also other bodies like glass, rubber, nylon, etc. Calculation algorithms for X-ray inspection of foreign bodies in foods have been reported. In food inspection systems, it is important that inspection is high precision, with high speed that is as fast as conveyor belts. Using Statistical methods, we construct a higher precision method than usual methods. We focused on Kittler's minimum error thresholding. In the usual Kittler's method, order n-squared calculations are required for distributed calculation, so it is not suitable for high speed food inspection. We find that using approximations of variances in Kittler's method is not too critical for practical use. Using it, we be come able to inspect for foreign bodies that were not able to be inspected for so far. (author)

  16. Total reflection x-ray fluorescence - an approach to nanoanalysis

    International Nuclear Information System (INIS)

    Klockenkaemper, R.

    2000-01-01

    X-ray fluorescence analysis (XRFA) is a powerful tool used for industrial production, geological prospecting and for environmental control. However, the method suffers from a lack of sensitivity so that analyses are restricted to microanalytical investigations. That means: the sample amount needed for analysis is above some 10 micrograms, concentrations to be determined have to be on the μg/ml level, and thin layers to be characterized must be of micrometer thickness. In contrast to conventional XRFA, total-reflection X-ray fluorescence (TXRF) is extremely sensitive and even allows nano-analytical investigations. Three different ways can be taken: (i) use of minute sample amounts of only 10 nano-grams, (ii) determination of extreme traces below ng/ml and (iii) surface analysis and depth profiling of shallow layers with nano-meter thickness. In this lecture, the basic physical phenomena of total reflection and standing waves are outlined. The experimental equipment for TXRF is sketched out and commercially available instruments of different manufacturers are compared. Furthermore, examples are given for the three kinds of nano-analytical applications: ultra-micro, analysis, ultra trace analysis and mono- and thin-layer analysis. (author)

  17. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  18. Monitoring body iron burden using X-ray fluorescence (XRF)

    International Nuclear Information System (INIS)

    Farquharson, M.J.; Bagshaw, A.P.

    2001-01-01

    X-ray fluorescence, using Cu K alpha and K beta radiation, has been used to measure the Fe content of skin of two groups of rats, one Fe overloaded and one control group. These skin Fe levels were compared to the liver and heart Fe levels measured using colorimetry. Correlation coefficients of 0.86 and 0.88 respectively were found indicating that skin Fe levels may be a potential marker for body iron burden.

  19. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  20. Determination of sulphur with total reflection x-ray spectrometry

    International Nuclear Information System (INIS)

    Steinmeyer, S.; Kolbesen, B.O.

    2000-01-01

    The potential and limitations of total reflection x-ray spectrometry (TXRF) were tested for the quantitative determination of the light element sulphur in inorganic and biological samples. As representatives of inorganic samples alkali, transition metal, magnesium and aluminum sulphates were investigated. As biological samples the sulphur containing amino acid methionine and the pharmaceutical drug insulin were chosen. All measurements were performed on a TXRF-spectrometer EXTRA IIA (Atomika Instruments, Oberschleissheim/Germany) using tungsten L-radiation as the excitation tube. Various concentrations of all samples ranging from 20 mg/l to 0.5 mg/l were determined. In addition the surface topography and thickness of the dry residue of these samples were investigated with SEM and a thickness profilometer (Alpha-Step). The result show that the reliable determination of sulphur in sulphates depends on the cation involved. Alkali sulphates like Na 2 SO 4 , or K 2 SO 4 form bulky residues resulting in significant deviations of the recovery rate of sulphur. In this case the use of smoothing detergents like 1 % HF, 1 % malic acid and 2 % hydrazinhydrat was found to be necessary for accurate determination. The results for the biological samples agree well with the expected values. The investigations lead to the conclusion that TXRF combined with a proper samples preparation is well suited for the determination of sulphur in different samples with various concentrations and matrices. (author)

  1. Thin film characterization by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Danel, Adrien; Nolot, Emmanuel; Veillerot, Marc; Olivier, Segolene; Decorps, Tifenn; Calvo-Munoz, Maria-Luisa; Hartmann, Jean-Michel; Lhostis, Sandrine; Kohno, Hiroshi; Yamagami, Motoyuki; Geoffroy, Charles

    2008-01-01

    Sensitive and accurate characterization of films thinner than a few nm used in nanoelectronics represents a challenge for many conventional production metrology tools. With capabilities in the 10 10 at/cm 2 , methods usually dedicated to contamination analysis appear promising, especially Total-reflection X-Ray Fluorescence (TXRF). This study shows that under usual configuration for contamination analysis, with incident angle smaller than the critical angle of the substrate, TXRF signal saturation occurs very rapidly for dense films (below 0.5 nm for HfO 2 films on Si wafers using a 9.67 keV excitation at 0.5 deg.). Increasing the incident angle, the range of linear results can be extended, but on the other hand, the TXRF sensitivity is degraded because of a strong increase of the measurement dead time. On HfO 2 films grown on Si wafers, an incident angle of 0.32 deg. corresponding to a dead time of 95% was used to achieve linear analysis up to 2 nm. Composition analysis by TXRF, and especially the detection of minor elements into thin films, requires the use of a specific incident angle to optimize sensitivity. Although quantitative analyses might require specific calibration, this work shows on Co-based films that the ratio between minor elements (W, P, Mo) and Co taking into account their relative sensitivity factors is a good direct reading of the composition

  2. X-ray total reflection mirrors for coherent illumination

    CERN Document Server

    Ishikawa, T; Yabashi, M; Souvorov, A; Yamauchi, K; Yamamura, K; Mimura, H; Saito, A; Mori, Y

    2002-01-01

    X-ray mirrors for coherent illumination demand much higher surface quality than is achievable with the conventional polishing techniques. Plasma chemical vaporization machining (CVM) and elastic emission machining (EEM) have been applied for x-ray mirror manufacturing. Figure error of a flat silicon single crystal mirrors made with CVM+EEM process was reduced to 2.0 nm peak-to-valley and 0.2 nm RMS. The machining process was also applied to make elliptical mirrors. One-dimensional focusing with a single elliptical mirror showed diffraction-limited properties with the focal width of 200 nm. Two-dimensional focusing with Kirkpatric-Baez configuration gave a focal spot size of 200 nm x 200 nm. (author)

  3. Patient size and x-ray transmission in body CT.

    Science.gov (United States)

    Ogden, Kent; Huda, Walter; Scalzetti, Ernest M; Roskopf, Marsha L

    2004-04-01

    Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.

  4. Sweeping total reflection X-ray fluorescence optimisation to monitor the metallic contamination into IC manufacturing

    International Nuclear Information System (INIS)

    Borde, Yannick; Danel, Adrien; Roche, Agnes; Veillerot, Marc

    2008-01-01

    Among the methods available on the market today to control as metallic contamination in integrated circuit manufacturing, Sweeping Total reflection X-ray Fluorescence mode appears a very good method, providing fast and entire wafer mapping. With the goal of a pertinent use of Sweeping Total reflection X-ray Fluorescence in advanced Integrated Circuit manufacturing this work discusses how acceptable levels of contamination specified by the production (low levels to be detected) can be taken into account. The relation between measurement results (surface coverage, throughput, low limit of detection, limit of quantification, quantification of localized contamination) and Sweeping Total reflection X-ray Fluorescence parameters (number of measurement points and integration time per point) is presented in details. In particular, a model is proposed to explain the mismatch between actual surface contamination in a localized spot on wafer and Total reflection X-ray Fluorescence reading. Both calibration and geometric issues have been taken into account

  5. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Maind, S.D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S.K.

    2010-01-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3 /HClO 4 , mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  6. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  7. Confocal total reflection X-ray fluorescence technology based on an elliptical monocapillary and a parallel polycapillary X-ray optics.

    Science.gov (United States)

    Zhu, Yu; Wang, Yabing; Sun, Tianxi; Sun, Xuepeng; Zhang, Xiaoyun; Liu, Zhiguo; Li, Yufei; Zhang, Fengshou

    2018-07-01

    A total reflection X-ray fluorescence (TXRF) spectrometer based on an elliptical monocapillary X-ray lens (MXRL) and a parallel polycapillary X-ray lens (PPXRL) was designed. This TXRF instrument has micro focal spot, low divergence and high intensity of incident X-ray beam. The diameter of the focal spot of MXRL was 16.5 µm, and the divergence of the incident X-ray beam was 3.4 mrad. We applied this TXRF instrument to the micro analysis of a single-layer film containing Ni deposited on a Si substrate by metal vapor vacuum arc ion source. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Examination procedure for making an X-ray of one layer of an object (body)

    International Nuclear Information System (INIS)

    1977-01-01

    The paper describes experimental equipment with a radiation source such as gamma or X-ray radiation sources, and a radiation detector, which are mechanically coupled with one another. This setup is used for making an X-ray image of one layer of the body. (G.C.)

  9. Elemental concentration analysis in prostate tissues using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Leitão, R.G.; Palumbo, A.; Souza, P.A.V.R.; Pereira, G.R.; Canellas, C.G.L.; Anjos, M.J.; Nasciutti, L.E.; Lopes, R.T.

    2014-01-01

    Prostate cancer (PCa) currently represents the second most prevalent malignant neoplasia in men, representing 21% of all cancer cases. Benign Prostate Hyperplasia (BPH) is an illness prevailing in men above the age of 50, close to 90% after the age of 80. The prostate presents a high zinc concentration, about 10-fold higher than any other body tissue. In this work, samples of human prostate tissues with cancer, BPH and normal tissue were analyzed utilizing total reflection X-ray fluorescence spectroscopy using synchrotron radiation technique (SR-TXRF) to investigate the differences in the elemental concentrations in these tissues. SR-TXRF analyses were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, São Paulo. It was possible to determine the concentrations of the following elements: P, S, K, Ca, Fe, Cu, Zn and Rb. By using Mann–Whitney U test it was observed that almost all elements presented concentrations with significant differences (α=0.05) between the groups studied. - Highlights: ► Prostate cancer is the most frequently diagnosed form of cancer in men. ► Intracellular Zn is correlated with proliferation, differentiation, or apoptosis. ► The prostate gland accumulate high concentration of Zn. ► SR-TXRF is a technique widely used in the analysis of low concentration in samples

  10. Total and available metal contents in sediments by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Sobrinho, Gilmar A.; Jesus, Edgar F.O. de; Lopes, Ricardo T.

    2002-01-01

    In this work the total and available contents of Al, Si, Cl, K, Mn, Fe, Co, Ni, Cu, Zn, Sr, Zr, Ba, Ce and Pb in sediments from river Atibaia were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence technique. The detection limits for K series varies from 200 ng.mL -1 for Al to 2 ng.mL -1 for Zn while for L series the value varies from 20 ng.mL -1 for Ba to 10 ng.mL -1 for Pb. The samples were submitted to two different processes, in order to obtain the total and biological available metal contents. The information about metal content is a important parameter for a correct evaluation about the hydrologic cycle in Piracicaba basin. All the measure were carried out at the National Synchrotron Light Laboratory, Campinas, SP, Brazil, using a white beam for excitation. (author)

  11. Uranium soft x-ray total attenuation coefficients

    International Nuclear Information System (INIS)

    Del Grande, N.K.; Oliver, A.J.

    1981-01-01

    Uranium total attenuation coefficients were measured continuously from 0.84 to 6.0 keV and at selected higher energies using a vacuum single crystal diffractometer and flow-proportional counter. Statistical fluctuations ranged from 0.5% to 2%. The overall accuracy was 3%. Prominent structure was measured within 20 eV of the M 5 (3.552 keV) and M 4 (3.728 keV) edges. Jump ratios were determined from log-log polynomial fits to data at energies apart from the near-edge regions. These data were compared with calculations based on a relativistic HFS central potential model and with previously tabulated data

  12. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  13. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  14. Total-reflection X-ray fluorescence analysis of Austrian wine

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, X. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Kregsamer, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Wobrauschek, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Streli, C. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria)]. E-mail: streli@ati.ac.at

    2006-11-15

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 {mu}l of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines.

  15. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    International Nuclear Information System (INIS)

    Fernandez-Ruiz, R.; Garcia-Heras, M.

    2008-01-01

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies

  16. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    Gruber, X.; Kregsamer, P.; Wobrauschek, P.; Streli, C.

    2006-01-01

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  17. Analysis of archaeological ceramics by total-reflection X-ray fluorescence: Quantitative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Modulo C-9, Laboratorio de TXRF, Crta. Colmenar, Km 15, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Garcia-Heras, M. [Grupo de Arqueometria de Vidrios y Materiales Ceramicos, Instituto de Historia, Centro de Ciencias Humanas y Sociales, CSIC, C/ Albasanz, 26-28, 28037 Madrid (Spain)

    2008-09-15

    This paper reports the quantitative methodologies developed for the compositional characterization of archaeological ceramics by total-reflection X-ray fluorescence at two levels. A first quantitative level which comprises an acid leaching procedure, and a second selective level, which seeks to increase the number of detectable elements by eliminating the iron present in the acid leaching procedure. Total-reflection X-ray fluorescence spectrometry has been compared, at a quantitative level, with Instrumental Neutron Activation Analysis in order to test its applicability to the study of this kind of materials. The combination of a solid chemical homogenization procedure previously reported with the quantitative methodologies here presented allows the total-reflection X-ray fluorescence to analyze 29 elements with acceptable analytical recoveries and accuracies.

  18. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Innis, Vallerie Ann A.

    2006-01-01

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  19. Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, Ursula Elisabeth Adriane, E-mail: ursula.fittschen@chemie.uni-hamburg.de [Institut für Anorganische und Angewandte Chemie, Universität Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Menzel, Magnus [Institut für Anorganische und Angewandte Chemie, Universität Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Scharf, Oliver [IfG Institute for Scientific Instruments GmbH, Berlin (Germany); Radtke, Martin; Reinholz, Uwe; Buzanich, Günther [BAM Federal Institute of Materials Research and Testing, Berlin (Germany); Lopez, Velma M.; McIntosh, Kathryn [Los Alamos National Laboratory, Los Alamos, NM (United States); Streli, Christina [Atominstitut, TU Wien, Vienna (Austria); Havrilla, George Joseph [Los Alamos National Laboratory, Los Alamos, NM (United States)

    2014-09-01

    Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by “drop on demand” technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. - Highlights: • Use of a color X-ray camera and drop on demand printing to diagnose X-ray shading • Specimens were obtained uniform and well-defined in shape and concentration by printing. • Direct visualization and determination of shading in such specimens using the camera.

  20. Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera

    International Nuclear Information System (INIS)

    Fittschen, Ursula Elisabeth Adriane; Menzel, Magnus; Scharf, Oliver; Radtke, Martin; Reinholz, Uwe; Buzanich, Günther; Lopez, Velma M.; McIntosh, Kathryn; Streli, Christina; Havrilla, George Joseph

    2014-01-01

    Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by “drop on demand” technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. - Highlights: • Use of a color X-ray camera and drop on demand printing to diagnose X-ray shading • Specimens were obtained uniform and well-defined in shape and concentration by printing. • Direct visualization and determination of shading in such specimens using the camera

  1. Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors

    Energy Technology Data Exchange (ETDEWEB)

    Mergler, S.; Rieken, R.; Evenhuis, H.M.; Penning, C. [Erasmus University Medical Centre, Intellectual Disability Medicine, Department of General Practice, PO Box 2040, CA, Rotterdam (Netherlands); Tibboel, D. [Erasmus University Medical Centre, Department of Pediatric Surgery, Rotterdam (Netherlands); Rijn, R.R. van [Academic Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2012-05-15

    Children with severe neurological impairment and intellectual disability (ID) are susceptible for developing low bone mineral density (BMD) and fractures. BMD is generally measured with dual-energy X-ray absorptiometry (DXA). To describe the occurrence of factors that may influence the feasibility of DXA and the accuracy of DXA outcome in children with severe neurological impairment and ID. Based on literature and expert opinion, a list of disrupting factors was developed. Occurrence of these factors was assessed in 27 children who underwent DXA measurement. Disrupting factors that occurred most frequently were movement during measurement (82%), aberrant body composition (67%), small length for age (56%) and scoliosis (37%). The number of disrupting factors per child was mean 5.3 (range 1-8). No correlation was found between DXA outcomes and the number of disrupting factors. Factors that may negatively influence the accuracy of DXA outcome are frequently present in children with severe neurological impairment and ID. No systematic deviation of DXA outcome in coherence with the amount of disrupting factors was found, but physicians should be aware of the possible influence of disrupting factors on the accuracy of DXA. (orig.)

  2. Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors

    International Nuclear Information System (INIS)

    Mergler, S.; Rieken, R.; Evenhuis, H.M.; Penning, C.; Tibboel, D.; Rijn, R.R. van

    2012-01-01

    Children with severe neurological impairment and intellectual disability (ID) are susceptible for developing low bone mineral density (BMD) and fractures. BMD is generally measured with dual-energy X-ray absorptiometry (DXA). To describe the occurrence of factors that may influence the feasibility of DXA and the accuracy of DXA outcome in children with severe neurological impairment and ID. Based on literature and expert opinion, a list of disrupting factors was developed. Occurrence of these factors was assessed in 27 children who underwent DXA measurement. Disrupting factors that occurred most frequently were movement during measurement (82%), aberrant body composition (67%), small length for age (56%) and scoliosis (37%). The number of disrupting factors per child was mean 5.3 (range 1-8). No correlation was found between DXA outcomes and the number of disrupting factors. Factors that may negatively influence the accuracy of DXA outcome are frequently present in children with severe neurological impairment and ID. No systematic deviation of DXA outcome in coherence with the amount of disrupting factors was found, but physicians should be aware of the possible influence of disrupting factors on the accuracy of DXA. (orig.)

  3. Development of a total reflection X-ray fluorescence spectrometer for ...

    Indian Academy of Sciences (India)

    Unknown

    design and use of a peltier cooled solid state detector for energy dispersive detection. Alignment and ... X-ray beam at a glancing angle less than the critical angle at which total ... materials is < 1 so that external total reflection takes place at an ...

  4. Microanalysis of old violin varnishes by total-reflection X-ray fluorescence

    Science.gov (United States)

    von Bohlen, Alex; Meyer, Friedrich

    1997-07-01

    Total reflection X-ray fluorescence was used to characterize elements (with Z>13) contained in varnishes applied by prominent violin makers during the last five centuries. Direct analyses of small flakes with masses varnish. Higher amounts of Fe, As and Pb were found in old products, Mn, Co, Cu, Zn and Pb were used in more recent varnishes.

  5. The X-ray fluorescent method for determination of total sulphur in bituminous coals

    International Nuclear Information System (INIS)

    Widowska-Kusmierska, J.; Siess, K.

    1979-01-01

    The X-ray fluorescent technique for the determination of total sulphur covering concentrations from 0,1 to 10% has been applied for bituminous coals showing a great variability in qualitative and quantitative composition of mineral matter (ash). The described method is a quick one giving results during one hour. The obtained good accuracy of determinations gives prospects for wide industrial application. (author)

  6. Total reflection X-ray fluorescence with synchrotron radiation applied to biological and environmental samples

    International Nuclear Information System (INIS)

    Simabuco, S.M.; Matsumoto, E.; Jesus, E.F.O.; Lopes, R.T.; Perez, C.; Nascimento Filho, V.F.; Costa, R.S.S.; Tavares do Carmo, M.G.; Saunders, C.

    2001-01-01

    Full text: The Total Reflection X-ray Fluorescence has been applied for trace elements in water and aqueous solutions, environmental samples and biological materials after sample preparation and to surface analysis of silicon wafers. The present paper shows some results of applications for rainwater, atmospheric particulate material, colostrum and nuclear samples. (author)

  7. Total chemical synthesis and X-ray structure of kaliotoxin by racemic protein crystallography.

    Science.gov (United States)

    Pentelute, Brad L; Mandal, Kalyaneswar; Gates, Zachary P; Sawaya, Michael R; Yeates, Todd O; Kent, Stephen B H

    2010-11-21

    Here we report the total synthesis of kaliotoxin by 'one pot' native chemical ligation of three synthetic peptides. A racemic mixture of D- and L-kaliotoxin synthetic protein molecules gave crystals in the centrosymmetric space group P1 that diffracted to atomic-resolution (0.95 Å), enabling the X-ray structure of kaliotoxin to be determined by direct methods.

  8. Lumbar spine and total-body dual-energy X-ray absorptiometry in children with severe neurological impairment and intellectual disability: a pilot study of artefacts and disrupting factors

    NARCIS (Netherlands)

    Mergler, S.; Rieken, R.; Tibboel, D.; Evenhuis, H. M.; van Rijn, R. R.; Penning, C.

    2012-01-01

    Children with severe neurological impairment and intellectual disability (ID) are susceptible for developing low bone mineral density (BMD) and fractures. BMD is generally measured with dual-energy X-ray absorptiometry (DXA). To describe the occurrence of factors that may influence the feasibility

  9. Half-body x-ray suppresses the acquisition of delayed-type hypersensitivity in the mouse

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, Jr, H C

    1979-01-01

    800 R half-body x-ray suppressed the acquisition of allergic contact dermatitis in mice (1) if the x-ray field included the lymph nodes regional to the sensitization site, and (2) when x-ray was given during, but not immediately before, induction of the sensitivity.

  10. An optimised set-up for total reflection particle induced X-ray emission

    International Nuclear Information System (INIS)

    Kan, J.A. van; Vis, R.D.

    1997-01-01

    MeV proton beams at small angles of incidence (0-35 mrad) are used to analyse trace elements on flat surfaces such as Si wafers or quartz substrates. In these experiments, the particle induced X-ray emission (PIXE) signal is used in a new optimized set-up. This set-up is constructed in such a way that the X-ray detector can reach very large solid angles, larger than 1 sr. Use of these large detector solid angles, combined with the reduction of bremsstrahlung background, affords limits of detection (LOD) of the order of 10 10 at cm -2 using total reflection particle induced X-ray emission (TPIXE). The LODs from earlier TPIXE measurements in a non-optimized set-up are used to estimate LODs in the new TPIXE set-up. Si wafers with low surface concentrations of V, Ni, Cu and Ag are used as standards to calibrate the LODs found with this set-up. The metal concentrations are determined by total reflection X-ray fluorescence (TXRF). The TPIXE measurements are compared with TXRF measurements on the same wafers. (Author)

  11. Measuring body composition in overweight individuals by dual energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Brownbill, Rhonda A; Ilich, Jasminka Z

    2005-01-01

    Dual energy x-ray absorptiometry (DXA) is widely used for body composition measurements in normal-weight and overweight/obese individuals. The limitations of bone densitometers have been frequently addressed. However, the possible errors in assessing body composition in overweight individuals due to incorrect positioning or limitations of DXA to accurately assess both bone mineral density and body composition in obese individuals have not received much attention and are the focus of this report. We discuss proper ways of measuring overweight individuals and point to some studies where that might not have been the case. It appears that currently, the most prudent approach to assess body composition of large individuals who cannot fit under the scanning area would be to estimate regional fat, namely the regions of thigh and/or abdomen. Additionally, using two-half body scans, although time consuming, may provide a relatively accurate measurement of total body fat, however, more studies using this technique are needed to validate it. Researchers using bone densitometers for body composition measurements need to have an understanding of its limitations in overweight individuals and address them appropriately when interpreting their results. Studies on accuracy and precision in measurements of both bone and soft tissue composition in overweight individuals using available densitometers are needed

  12. Abstracts of the 8th Conference on total reflection x-ray fluorescence analysis and related methods

    International Nuclear Information System (INIS)

    Wobrauschek, P.

    2000-01-01

    The 8. conference on total reflection x-ray fluorescence analysis and related methods held from 25.9 to 29.9.2000 contains 79 abstracts about x-ray fluorescence analysis (XRFA) as a powerful tool used for industrial production, geological prospecting and for environmental control. Total reflection x-ray fluorescence spectroscopy is also a tool used for chemical analysis in medicine, industry and research. (E.B.)

  13. Anthropometrics and body composition by dual energy X-ray in children of obese women

    DEFF Research Database (Denmark)

    Tanvig, Mette; Vinter, Christina A; Jørgensen, Jan S

    2014-01-01

    of the RCT mothers and in 97 reference group children with Body Mass Index (BMI) Z-score as a primary outcome. Body composition was estimated by Dual Energy X-ray (DEXA) in 123 successful scans out of 147 (84%). RESULTS: No differences between randomized groups were seen in mean (95% C.I.) BMI Z...

  14. Total Reflection X-ray Fluorescence Analysis (TXRF) using the high flux SAXS camera

    CERN Document Server

    Wobrauschek, P; Pepponi, G; Bergmann, A; Glatter, O

    2002-01-01

    Combining the high photon flux from a rotating anode X-ray tube with an X-ray optical component to focus and monochromatize the X-ray beam is the most promising instrumentation for best detection limits in the modern XRF laboratory. This is realized by using the design of a high flux SAXS camera in combination with a 4 kW high brilliant rotating Cu anode X-ray tube with a graded elliptically bent multilayer and including a new designed module for excitation in total reflection geometry within the beam path. The system can be evacuated thus reducing absorption and scattering of air and removing the argon peak in the spectra. Another novelty is the use of a Peltier cooled drift detector with an energy resolution of 148 eV at 5.9 keV and 5 mm sup 2 area. For Co detection limits of about 300 fg determined by a single element standard have been achieved. Testing a real sample NIST 1643d led to detection limits in the range of 300 ng/l for the medium Z.

  15. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, Thomas Peter; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat...... mass in IDDM patients and control subjects, as compared to other reference methods, i.e. total body potassium by 40K whole body counting (TBK), total body water by tritiated water (TBW), bioelectrical impedance analysis (BIA) and 24-h urinary creatinine excretion (Ucrea). A total of 13 healthy controls....... The agreement between FFM estimated by DXA and the other methods, expressed as mean difference +/- 2 SD was; for DXA vs. TBK, 0.09 +/- 6.26 and 0.50 +/- 5.26 kg for controls and IDDM patients respectively; DXA vs. TBW, -2.07 +/- 2.56 and -1.07 +/- 4.58 kg; DXA vs. Ucrea, -2.62 +/- 8.02 and 2.00 +/- 10.0 kg; DXA...

  16. Multielemental analysis in cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Barbosa, R.F.; Anjos, M.J. dos; Jesus, E.F.O. de; Lopes, R.T.; Moreira, S.

    2008-01-01

    Full text: It is well known that trace elements have important ejects in the life processes. Some of these elements are toxic for the human even at a very low level of intake. It is known that tobacco plant easily absorbs the heavy metals from the soil, especially Cd and Ni, accumulating them in its leaves. Part of these metals are transferred from tobacco to human body where they will be accumulated and damage some organs, mainly kidneys and liver. In this way, cigarettes are responsible for the death of millions of people in the world, about one death every eight seconds. The aim of this work was to determine the elemental concentrations of ten different elements in tobacco of Brazilian cigarettes used Total Reflection X-Ray Fluorescence with Synchrotron Radiation method. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. A qualitative analysis of spectral peaks showed that the samples contained potassium, calcium, titanium, chromium, manganese, iron, copper, rubidium and strontium. Among these elements, calcium, potassium and iron presented the highest concentrations. There was a wide range in the elemental concentrations in the tobacco, due various factors, such as agricultural practices, soil characteristics, climatic conditions and plant varieties. Our results are in good concern with the results reported by the scientific literature

  17. Parameter study of self-absorption effects in Total Reflection X-ray Fluorescence-X-ray Absorption Near Edge Structure analysis of arsenic

    International Nuclear Information System (INIS)

    Meirer, F.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Kregsamer, P.; Zoeger, N.; Falkenberg, G.

    2008-01-01

    Total reflection X-ray Fluorescence (TXRF) analysis in combination with X-ray Absorption Near Edge Structure (XANES) analysis is a powerful method to perform chemical speciation studies at trace element levels. However, when measuring samples with higher concentrations and in particular standards, damping of the oscillations is observed. In this study the influence of self-absorption effects on TXRF-XANES measurements was investigated by comparing measurements with theoretical calculations. As(V) standard solutions were prepared at various concentrations and dried on flat substrates. The measurements showed a correlation between the damping of the oscillations and the As mass deposited. A Monte-Carlo simulation was developed using data of the samples shapes obtained from confocal white light microscopy. The results showed good agreement with the measurements; they confirmed that the key parameters are the density of the investigated atom in the dried residues and the shape of the residue, parameters that combined define the total mass crossed by a certain portion of the incident beam. The study presents a simple approach for an a priori evaluation of the self-absorption in TXRF X-ray absorption studies. The consequences for Extended X-ray Absorption Fine Structure (EXAFS) and XANES measurements under grazing incidence conditions are discussed, leading to the conclusion that the damping of the oscillations seems to make EXAFS of concentrated samples non feasible. For XANES 'fingerprint' analysis samples should be prepared with a deposited mass and sample shape leading to an acceptable absorption for the actual investigation

  18. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-01-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples

  19. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-12-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples.

  20. Applications of total reflection X-ray fluorescence in multi-element analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.; Knoth, J.

    1985-01-01

    Although Total Reflection X-Ray Fluorescence Analysis (TXRF) became available for practical applications and routine measurements only few years ago, the number of programmes that make use of this method is increasing rapidly. The scope of work is widespread over environmental research and monitoring, mineralogy, mineral exploration, oceanography, biology, medicine and biochemistry. The present paper gives a brief survey of these applications and summarizes some of them which are typical for quite different matrices. (orig.)

  1. Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination

    International Nuclear Information System (INIS)

    Vives, A.E.S.; Brienza, S.M.B.; Moreira, S.; Zucchi, O.L.A.; Nascimento Filho, V.F.

    2006-01-01

    The objective of this study was to use synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF) for the determination of metals and other elements in food available to the population in commercial establishments, in order to evaluate the risks of contamination by these products. The analyzed species were vegetables, leafy vegetables, fruits, cereal and grain. The results indicated that some species were contaminated by Cr, Cu, Zn and Pb with concentrations much higher than the reference values. (author)

  2. Top layer's thickness dependence on total electron-yield X-ray standing-wave

    International Nuclear Information System (INIS)

    Ejima, Takeo; Yamazaki, Atsushi; Banse, Takanori; Hatano, Tadashi

    2005-01-01

    A Mo single-layer film with a stepwise thickness distribution was fabricated on the same Mo/Si reflection multilayer film. Total electron-yield X-ray standing-wave (TEY-XSW) spectra of the aperiodic multilayer were measured with reflection spectra. The peak positions of the standing waves in the TEY-XSW spectra changed as the film thickness of the top Mo-layer increased

  3. Total reflection X-ray fluorescence analysis with synchrotron radiation monochromatized by multilayer structures

    International Nuclear Information System (INIS)

    Rieder, R.; Wobrauschek, P.; Ladisich, W.; Streli, C.; Aiginger, H.; Garbe, S.; Gaul, G.; Knoechel, A.; Lechtenberg, F.

    1995-01-01

    To achieve lowest detection limits in total reflection X-ray fluorescence analysis (TXRF) synchrotron radiation has been monochromatized by a multilayer structure to obtain a relative broad energy band compared to Bragg single crystals for an efficient excitation. The energy has been set to 14 keV, 17.5 keV, 31 keV and about 55 keV. Detection limits of 20 fg and 150 fg have been achieved for Sr and Cd, respectively. ((orig.))

  4. Dual energy X-Ray absorptiometry body composition reference values from NHANES.

    Directory of Open Access Journals (Sweden)

    Thomas L Kelly

    Full Text Available In 2008 the National Center for Health Statistics released a dual energy x-ray absorptiometry (DXA whole body dataset from the NHANES population-based sample acquired with modern fan beam scanners in 15 counties across the United States from 1999 through 2004. The NHANES dataset was partitioned by gender and ethnicity and DXA whole body measures of %fat, fat mass/height(2, lean mass/height(2, appendicular lean mass/height(2, %fat trunk/%fat legs ratio, trunk/limb fat mass ratio of fat, bone mineral content (BMC and bone mineral density (BMD were analyzed to provide reference values for subjects 8 to 85 years old. DXA reference values for adults were normalized to age; reference values for children included total and sub-total whole body results and were normalized to age, height, or lean mass. We developed an obesity classification scheme by using estabbody mass index (BMI classification thresholds and prevalences in young adults to generate matching classification thresholds for Fat Mass Index (FMI; fat mass/height(2. These reference values should be helpful in the evaluation of a variety of adult and childhood abnormalities involving fat, lean, and bone, for establishing entry criteria into clinical trials, and for other medical, research, and epidemiological uses.

  5. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  6. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Anjos, M.J.; Lopes, R.T.; Jesus, E.F.O. de; Moreira, S.; Barroso, R.C.; Castro, C.R.F.

    2003-01-01

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  7. Single particle transfer for quantitative analysis with total-reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

    2006-01-01

    The technique of single particle transfer was applied to quantitative analysis with total-reflection X-ray fluorescence (TXRF) spectrometry. The technique was evaluated by performing quantitative analysis of individual Cu particles with diameters between 3.9 and 13.2 μm. The direct quantitative analysis of the Cu particle transferred onto a Si carrier gave a discrepancy between measured and calculated Cu amounts due to the absorption effects of incident and fluorescent X-rays within the particle. By the correction for the absorption effects, the Cu amounts in individual particles could be determined with the deviation within 10.5%. When the Cu particles were dissolved with HNO 3 solution prior to the TXRF analysis, the deviation was improved to be within 3.8%. In this case, no correction for the absorption effects was needed for quantification

  8. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Nascimento Filho, Virgilio F.; Zucchi, Orgheda L.D.A.

    2005-01-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 μL of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1μg.L -1 for Mn and Fe to 15μg.L -1 for P. (author)

  9. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Recursos Hidricos]. E-mail: silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br; Zucchi, Orgheda L.D.A. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas de Ribeirao Preto]. E-mail: olzucchi@fcfrp.usp.br

    2005-07-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 {mu}L of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1{mu}g.L{sup -1} for Mn and Fe to 15{mu}g.L{sup -1} for P. (author)

  10. TX 2000: total reflection and 45o energy dispersive x-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Pasti, F.; Torboli, A.; Valdes, M.

    2000-01-01

    This equipment, developed by Ital Structures, combines two kinds of energy dispersive X-ray fluorescence techniques, the first using total reflection geometry and the second conventional 45 o geometry. The equipment is completely controlled by a PC and to reach the condition of total reflection is very easy because it is enough to load the file with the right position for the corresponding energy. In this apparatus we used an x-ray tube with an alloy anode of Mo/W with a long fine focus at 2200 W. To monochromatize the x-ray beam while choosing, for example, the Mo K alpha or W L alpha or a piece of white spectrum of 33 keV, we use a highly reflective multilayer made of Si/W with 2d = 45.5 A o . The detector used in the equipment is a lithium drifted silicon detector (Si(Li)) with an excellent energy resolution of 135 eV at 5.9 keV and 1000 cps. We developed two programs written in Windows 95, 98 and NT for a 32 bit microprocessor. The first one is called TYACQ32 and has the following functions: first, complete control of the hardware, second automatic alignment of the TX 2000 spectrometer and third acquisition of spectra. The second program is EDXRF32. This is a program to accomplish spectrum and quantitative analysis for TXRF and EDXRF 45 o degrees analysis. (author)

  11. The role of total-reflection x-ray fluorescence in atomic spectroscopy

    International Nuclear Information System (INIS)

    Toelg, G.; Klockenkaemper, R.

    1993-01-01

    Total-reflection X-ray fluorescence (TXRF) is a universal and economic method for the simultaneous determination of elements with atomic numbers > 11 down to the lower pg-level. It is a microanalytical tool for the analysis of small sample amounts placed on flat carriers and for contaminations on flat sample surfaces. Analyses of stratified near-surface layers are made possible by varying the incident angle of the primary beam in the region of total-reflection. This non-destructive method is especially suitable for thin layers of a few nanometres, deposited on wafer material although not usable as a microprobe method with a high lateral resolution. Furthermore, depth profiles of biological samples can be recorded by means of microtome sectioning of only a few micrometres, as, for example in the gradient analysis of human organs. In addition to micro- and surface-layer analysis, TXRF is effectively applied to element trace analysis. Homogeneous solutions, for example aqueous solutions, high-purity acids or body fluids, are pipetted onto carriers and, after evaporation, the dry residues are analyzed directly down to the pg/ml region. Particularly advantageous is the absence of matrix effects, so that an easy calibration can be carried out by adding a single internal standard element. A digestion or separation step preceding the actual determination becomes necessary if a more complex matrix is to be analysed or especially low detection limits have to be reached. A critical evaluation of the recent developments in atomic spectroscopy places TXRF in a leading position. Its outstanding features compete with those of e.g. electrothermal atomic absorption spectrometry (ETAAS), microwave induced plasma optical emission spectroscopy (MIP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) in the field of micro- and trace analysis and with Rutherford backscattering (RBS) and secondary ion mass spectrometry (SIMS) in the surface-layer analysis. (author)

  12. CubeX: The CubeSAT X-ray Telescope for Elemental Abundance Mapping of Airless Bodies and X-ray Pulsar Navigation

    Science.gov (United States)

    Nittler, L. R.; Hong, J.; Kenter, A.; Romaine, S.; Allen, B.; Kraft, R.; Masterson, R.; Elvis, M.; Gendreau, K.; Crawford, I.; Binzel, R.; Boynton, W. V.; Grindlay, J.; Ramsey, B.

    2017-12-01

    The surface elemental composition of a planetary body provides crucial information about its origin, geological evolution, and surface processing, all of which can in turn provide information about solar system evolution as a whole. Remote sensing X-ray fluorescence (XRF) spectroscopy has been used successfully to probe the major-element compositions of airless bodies in the inner solar system, including the Moon, near-Earth asteroids, and Mercury. The CubeSAT X-ray Telescope (CubeX) is a concept for a 6U planetary X-ray telescope (36U with S/C), which utilizes Miniature Wolter-I X-ray optics (MiXO), monolithic CMOS and SDD X-ray sensors for the focal plane, and a Solar X-ray Monitor (heritage from the REXIS XRF instrument on NASA's OSIRIS-REx mission). CubeX will map the surface elemental composition of diverse airless bodies by spectral measurement of XRF excited by solar X-rays. The lightweight ( 1 kg) MiXO optics provide sub-arcminute resolution with low background, while the inherently rad-hard CMOS detectors provide improved spectral resolution ( 150 eV) at 0 °C. CubeX will also demonstrate X-ray pulsar timing based deep space navigation (XNAV). Successful XNAV will enable autonomous deep navigation with little to no support from the Deep Space Network, hence lowering the operation cost for many more planetary missions. Recently selected by NASA Planetary Science Deep Space SmallSat Studies, the first CubeX concept, designed to rideshare to the Moon as a secondary spacecraft on a primary mission, is under study in collaboration with the Mission Design Center at NASA Ames Research Center. From high altitude ( 6,000 km) frozen polar circular orbits, CubeX will study > 8 regions ( 110 km) of geological interest on the Moon over one year to produce a high resolution ( 2-3 km) elemental abundance map of each region. The novel focal plane design of CubeX also allows us to evaluate the performance of absolute navigation by sequential observations of several

  13. Total reflection X-ray Fluorescence determination of interfering elements rubidium and uranium by profile fitting

    Science.gov (United States)

    Dhara, Sangita; Khooha, Ajay; Singh, Ajit Kumar; Tiwari, M. K.; Misra, N. L.

    2018-06-01

    Systematic studies to assess the analytical parameters obtained in the total reflection X-ray fluorescence (TXRF) determinations of interfering elements Rb and U using profile fitting are reported in the present manuscript. The X-ray lines Rb Kα and U Lα having serious spectral interference (ΔE = 218 eV), have been used as analytical lines. The intensities of these X-ray lines have been assessed using profile fitting. In order to compare the analytical results of Rb determinations in presence of U, with and without U excitation, synchrotron radiation was tuned to energy just above and below the U Labs edge. This approach shall excite both Rb Kα and U Lα simultaneously and Rb Kα selectively. Finally, the samples were also analyzed with a laboratory based TXRF spectrometer. The analytical results obtained in all these conditions were comparable. The authenticity of the results was assessed by analyzing U with respect to Rb in Rb2U(SO4)3, a standard reference material for U. The average precision obtained for TXRF determinations was below 3% (RSD, n = 3, 1σ) and the percent deviation of TXRF values from the expected values calculated on the basis of sample preparation was within 3%.

  14. Manipulation of Muscle Creatine and Glycogen Changes Dual X-ray Absorptiometry Estimates of Body Composition.

    Science.gov (United States)

    Bone, Julia L; Ross, Megan L; Tomcik, Kristyen A; Jeacocke, Nikki A; Hopkins, Will G; Burke, Louise M

    2017-05-01

    Standardizing a dual x-ray absorptiometry (DXA) protocol is thought to provide a reliable measurement of body composition. We investigated the effects of manipulating muscle glycogen and creatine content independently and additively on DXA estimates of lean mass. Eighteen well-trained male cyclists undertook a parallel group application of creatine loading (n = 9) (20 g·d for 5 d loading; 3 g·d maintenance) or placebo (n = 9) with crossover application of glycogen loading (12 v 6 g·kg BM per day for 48 h) as part of a larger study involving a glycogen-depleting exercise protocol. Body composition, total body water, muscle glycogen and creatine content were assessed via DXA, bioelectrical impedance spectroscopy and standard biopsy techniques. Changes in the mean were assessed using the following effect-size scale: >0.2 small, >0.6, moderate, >1.2 large and compared with the threshold for the smallest worthwhile effect of the treatment. Glycogen loading, both with and without creatine loading, resulted in substantial increases in estimates of lean body mass (mean ± SD; 3.0% ± 0.7% and 2.0% ± 0.9%) and leg lean mass (3.1% ± 1.8% and 2.6% ± 1.0%) respectively. A substantial decrease in leg lean mass was observed after the glycogen depleting condition (-1.4% ± 1.6%). Total body water showed substantial increases after glycogen loading (2.3% ± 2.3%), creatine loading (1.4% ± 1.9%) and the combined treatment (2.3% ± 1.1%). Changes in muscle metabolites and water content alter DXA estimates of lean mass during periods in which minimal change in muscle protein mass is likely. This information needs to be considered in interpreting the results of DXA-derived estimates of body composition in athletes.

  15. Many-body effects in X-ray photoemission spectroscopy and electronic properties of solids

    International Nuclear Information System (INIS)

    Kohiki, S.

    1999-01-01

    Photoemission from a solid is evidently a many-body process since the motion of each electron cannot be independent of the motions of other electrons. In this article we review the reported many-body effects in X-ray photoemission such as extra-atomic relaxation energy, charge transfer satellite and energy loss structure which are informative in relation to the characteristics of solids. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    Energy Technology Data Exchange (ETDEWEB)

    Cibin, G. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxon OX110DE (United Kingdom); IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy); Universita' degli Studi di Roma Tre, Dipartimento di Scienze Geologiche, L.go S. Leonardo Murialdo 1, 00146 Roma (Italy)], E-mail: giannantonio.cibin@diamond.ac.uk; Marcelli, A. [INFN - Laboratori Nazionali di Frascati, P.O. Box 13, 00044 Frascati (Roma) (Italy); Maggi, V. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Sala, M. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Milano, Dipartimento di Scienze della Terra ' A. Desio' , Sez. Mineralogia, Via Mangiagalli 34, 20133 Milano (Italy); Marino, F.; Delmonte, B. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Albani, S. [Universita degli Studi di Milano-Bicocca, Dipartimento di Scienze dell' Ambiente e del Territorio, Piazza della Scienza 1, 20126 Milano (Italy); Universita degli Studi di Siena, Dottorato in Scienze Polari, via Laterina 8, 53100 Siena (Italy); Pignotti, S. [IMONT/EIM, Ente Italiano della Montagna, P.za dei Caprettari 70, 00176 Roma (Italy)

    2008-12-15

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 {mu}g range.

  17. First combined total reflection X-ray fluorescence and grazing incidence X-ray absorption spectroscopy characterization of aeolian dust archived in Antarctica and Alpine deep ice cores

    International Nuclear Information System (INIS)

    Cibin, G.; Marcelli, A.; Maggi, V.; Sala, M.; Marino, F.; Delmonte, B.; Albani, S.; Pignotti, S.

    2008-01-01

    Aeolian mineral dust archived in polar and mid latitude ice cores represents a precious proxy for assessing environmental and climatic variations at different timescales. In this respect, the identification of dust mineralogy plays a key role. In this work we performed the first preliminary X-ray absorption spectroscopy (XAS) experiments on mineral dust particles extracted from Antarctic and from Alpine firn cores using grazing incidence geometry at the Fe K-edge. A dedicated high vacuum experimental chamber was set up for normal-incidence and total-reflection X-Ray Fluorescence and Absorption Spectroscopy analyses on minor amounts of mineral materials at the Stanford Synchrotron Radiation Laboratory. Results show that this experimental technique and protocol allows recognizing iron inclusion mineral fraction on insoluble dust in the 1-10 μg range

  18. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field

    International Nuclear Information System (INIS)

    Vazquez, Cristina

    2004-01-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes

  19. The capabilities of total reflection X-ray fluorescence in the polymeric analytical field*1

    Science.gov (United States)

    Vázquez, Cristina

    2004-08-01

    This paper presents the capabilities of total reflection X-ray fluorescence (TXRF) as analytical technique specially focused in high-viscosity polymer dispersions. Appropriate sample preparation procedures are described taking into account the time stability of these dispersions. Special remarks considering different ways for drying samples in order to obtain the most uniform deposited film are investigated focusing on the behavior of aqueous and viscous systems. Due to the difficulty found for obtaining a homogeneous mixture between sample and internal standard in such systems, the use of Compton incoherent scattering is discussed as an alternative procedure for trace quantification in high viscous systems without any mixing processes.

  20. Determination of heavy metals in Damascus drinking water using total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Karajo, J.

    2000-01-01

    Total reflection x-ray fluorescence spectrometry and chemical preconcentration have applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 μg/l. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines. (author)

  1. Synchrotron total reflection X-ray fluorescence at BL-16 microfocus beamline of Indus-2

    Energy Technology Data Exchange (ETDEWEB)

    Tiwari, M. K., E-mail: mktiwari@rrcat.gov.in; Singh, A. K., E-mail: mktiwari@rrcat.gov.in; Das, Gangadhar, E-mail: mktiwari@rrcat.gov.in; Chowdhury, Anupam, E-mail: mktiwari@rrcat.gov.in; Lodha, G. S., E-mail: mktiwari@rrcat.gov.in [Indus Synchrotrons Utilisation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2014-04-24

    Determination of ultra trace elements is important in many disciplines both in basic and applied sciences. Numerous applications show their importance in medical science, environmental science, materials science, food processing and semiconductor industries and in maintaining the quality control of ultra pure chemicals and reagents. We report commissioning of a synchrotron based total reflection x-ray fluorescence (TXRF) facility on the BL-16 microfocus beamline of Indus-2. This paper describes the performance of the BL-16 TXRF spectrometer and the detailed description of its capabilities through examples of measured results.

  2. Total reflection X-ray fluorescence and archaeometry: Application in the Argentinean cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina); Laboratorio de Quimica de Sistemas Heterogeneos, Facultad de Ingenieria, Universidad de Buenos Aires, P. Colon 850 (C1063ACU), Buenos Aires (Argentina)], E-mail: Cristina.Vazquez@cnea.gov.ar; Albornoz, Ana [Agencia Rio Negro Cultura, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Hajduk, Adam [CONICET, Museo de la Patagonia F.P.Moreno, Centro Civico s/n Bariloche, Rio Negro (Argentina); Elkin, Dolores [CONICET Instituto Nacional de Antropologia y Pensamiento Latinoamericano, 3 de febrero 1378 (C1426AEL) Buenos Aires (Argentina); Custo, Graciela; Obrustky, Alba [Comision Nacional de Energia Atomica, Av. Gral Paz 1499 (B1650KNA) San Martin, Buenos Aires (Argentina)

    2008-12-15

    Archaeometry is an interdisciplinary research area involved in the development and use of scientific methods in order to answer questions concerned with the human history. In this way the knowledge of archaeological objects through advanced chemical and physical analyses permits a better preservation and conservation of the cultural heritage and also reveals materials and technologies used in the past. In this sense, analytical techniques play an important role in order to provide chemical information about cultural objects. Considering the non destructive characteristic of this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Taking into account the irreplaceable character of the archaeological and artistic materials considered in this study, analytical techniques must be adequate in order to prevent any alteration or damage and in addition to allow the conservation of their integrity. Total Reflection X-ray Fluorescence Spectrometry as a geometric variant of conventional X-ray fluorescence is a proved microanalytical technique considering the small amount of sample required for the analysis. A few micrograms are enough in order to reveal valuable information about elemental composition and in this context it is highly recommended for artwork studies. In this paper a case study is presented in which Total Reflection X-Ray Fluorescence Spectrometry has been successfully employed in the archaeometry field. Examples from Argentinean cultural heritage sites related with the determination of pigments in paintings on canvas and in rock sites as well as in underwater archaeology research are shown.

  3. Many-body effects in the mesoscopic x-ray edge problem

    International Nuclear Information System (INIS)

    Hentschel, Martina; Roeder, Georg; Ullmo, Denis

    2007-01-01

    Many-body phenomena, a key interest in the investigation of bulk solid state systems, are studied here in the context of the x-ray edge problem for mesoscopic systems. We investigate the many-body effects associated with the sudden perturbation following the x-ray exciton of a core electron into the conduction band. For small systems with dimensions at the nanoscale we find considerable deviations from the well-understood metallic case where Anderson orthogonality catastrophe and the Mahan-Nozieres-DeDominicis response cause characteristic deviations of the photoabsorption cross section from the naive expectation. Whereas the K-edge is typically rounded in metallic systems, we find a slightly peaked K-edge in generic mesoscopic systems with chaotic-coherent electron dynamics. Thus the behavior of the photoabsorption cross section at threshold depends on the system size and is different for the metallic and the mesoscopic case. (author)

  4. Three dimensional analysis of coelacanth body structure by computer graphics and X-ray CT images

    International Nuclear Information System (INIS)

    Suzuki, Naoki; Hamada, Takashi.

    1990-01-01

    Three dimensional imaging processes were applied for the structural and functional analyses of the modern coelacanth (Latimeria chalumnae). Visualization of the obtained images is performed with computer graphics on the basis of serial images by an X-ray CT scanning method. Reconstruction of three dimensional images of the body structure of coelacanth using the volume rendering and surface rendering methods provides us various information about external and internal shapes of this exquisite fish. (author)

  5. Autoradiographic changes in the kidney of the whole-body sublethally x-ray irradiated rat

    Energy Technology Data Exchange (ETDEWEB)

    Olinic, A; Uray, Z

    1977-01-01

    203Hg-hydroxymersalyl uptake/gram of kidney (HU), renal autoradiographic and histologic aspect after 800 R x-ray whole-body rat irradiation was studied. Twenty-four to seventy-two hours after irradiation, HU increased, while tubular autoradiographic granularity decreased. Their return to the control levels occurred gradually within two weeks. The relations of these findings to the early circulatory and dystrophic changes, as well as to the subsequent postirradiation restoring renal process are discussed.

  6. Total Reflection X-ray Fluorescence attachment module modified for analysis in vacuum

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Streli, C.; Kregsamer, P.; Meirer, F.; Jokubonis, C.; Markowicz, A.; Wegrzynek, D.; Chinea-Cano, E.

    2008-01-01

    Based on the design of the low cost Total Reflection X-Ray Fluorescence attachment module available since 1986 from Atominstitut (WOBRAUSCHEK-module) which can be attached to existing X-ray equipment, a new version was developed which allows the analysis of samples in vacuum. This design was in particular possible as the Peltier cooled light weight Silicon Drift Detector is following all adjustment procedures for total reflection as angle rotation and linear motion. The detector is mounted through a vacuum feed and O-ring tightening to the small vacuum chamber. The standard 30 mm round quartz, Si-wafer or Plexiglas reflectors are used to carry the samples. The reflectors are placed on the reference plane with the dried sample down looking facing in about 0.5 mm distance the up looking detector window. The reflectors are resting on 3 steel balls defining precisely the reference plane for the adjustment procedure. As the rotation axis of the module is in the plane of the reflector surface, angle dependent experiments can be made to distinguish between film and particulate type contamination of samples. Operating with a Mo anode at 50 kV and 40 mA with a closely attached multilayer monochromator and using a 10 mm 2 KETEK silicon drift detector with 8 μm Be window, a sensitivity of 70 cps/ng for Rb was measured and detection limits of 2 pg were obtained

  7. Revisiting the total ion yield x-ray absorption spectra of liquid water microjets

    International Nuclear Information System (INIS)

    Saykally, Richard J; Cappa, Chris D.; Smith, Jared D.; Wilson, Kevin R.; Saykally, Richard J.

    2008-01-01

    Measurements of the total ion yield (TIY) x-ray absorption spectrum (XAS) of liquid water by Wilson et al. (2002 J. Phys.: Condens. Matter 14 L221 and 2001 J. Phys. Chem. B 105 3346) have been revisited in light of new experimental and theoretical efforts by our group. Previously, the TIY spectrum was interpreted as a distinct measure of the electronic structure of the liquid water surface. However, our new results indicate that the previously obtained spectrum may have suffered from as yet unidentified experimental artifacts. Although computational results indicate that the liquid water surface should exhibit a TIY-XAS that is fundamentally distinguishable from the bulk liquid XAS, the new experimental results suggest that the observable TIY-XAS is actually nearly identical in appearance to the total electron yield (TEY-)XAS, which is a bulk probe. This surprising similarity between the observed TIY-XAS and TEY-XAS likely results from large contributions from x-ray induced electron stimulated desorption of ions, and does not necessarily indicate that the electronic structure of the bulk liquid and liquid surface are identical

  8. Direct analysis of biological samples by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue M, Marco P.; Hernandez-Caraballo, Edwin A.

    2004-01-01

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry

  9. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ovari, M.; Streli, C.; Wobrauschek, P.; Zaray, Gy.

    2009-01-01

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  10. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovari, M. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)], E-mail: ovari@chem.elte.hu; Streli, C.; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, Stadionallee 2, A-1020, Wien (Austria); Zaray, Gy. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary); Cooperative Research Centre of Environmental Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)

    2009-08-15

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  11. Chlorine determination in (U, Pu)C fuel by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Misra, Nand Lal; Dhara, Sangita; Mudher, Khush Dev Singh; Aggarwal, Suresh K.; Thakur, Uday Kumar; Shah, Dipti; Sawant, R.M.; Ramakumar, K.L.

    2007-01-01

    A Total Reflection X-ray Fluorescence (TXRF) method for the determination of chlorine in (U,Pu)C has been developed. The method involves calibration of the instrument with standard solutions and validation of TXRF determination of chlorine using synthetic standard solutions. Cl K α line excited with W L α source was used for TXRF determinations of chlorine. Chlorine present in trace amounts in (U,Pu)C samples was first separated by pyro hydrolysis. The evolved chlorine, in form of HCl, was collected in 5 mM NaOH solution. This solution was analyzed for chlorine by Total Reflection X-ray Fluorescence Spectrometry using cobalt as an internal standard. The TXRF detection limit of chlorine was found to be 3.6 pg with sample size of 30 μL. In order to assess the applicability of TXRF method for chlorine determinations in other nuclear materials, one U 3 O 8 trace element standard was also analyzed for chlorine in similar way. The precision of the method was found to be 25% (1 σ) at ng level in most of the cases. (author)

  12. Fundamental Movement Skill Proficiency and Body Composition Measured by Dual Energy X-Ray Absorptiometry in Eight-Year-Old Children

    Science.gov (United States)

    Slotte, Sari; Sääkslahti, Arja; Metsämuuronen, Jari; Rintala, Pauli

    2015-01-01

    Objective: The main aim was to examine the association between fundamental movement skills (FMS) and objectively measured body composition using dual energy X-ray absorptiometry (DXA). Methods: A study of 304 eight-year-old children in Finland. FMS were assessed with the "Test of gross motor development," 2nd ed. Total body fat…

  13. Partial body irradiation of small laboratory animals with an industrial X-ray tube

    International Nuclear Information System (INIS)

    Frenzel, Thorsten; Kruell, Andreas; Grohmann, Carsten; Schumacher, Udo

    2014-01-01

    Dedicated precise small laboratory animal irradiation sources are needed for basic cancer research and to meet this need expensive high precision radiation devices have been developed. To avoid such expenses a cost efficient way is presented to construct a device for partial body irradiation of small laboratory animals by adding specific components to an industrial X-ray tube. A custom made radiation field tube was added to an industrial 200 kV X-ray tube. A light field display as well as a monitor ionization chamber were implemented. The field size can rapidly be changed by individual inserts of MCP96 that are used for secondary collimation of the beam. Depth dose curves and cross sectional profiles were determined with the use of a custom made water phantom. More components like positioning lasers, a custom made treatment couch, and a commercial isoflurane anesthesia unit were added to complete the system. With the accessories described secondary small field sizes down to 10 by 10 mm 2 (secondary collimator size) could be achieved. The dosimetry of the beam was constructed like those for conventional stereotactical clinical linear accelerators. The water phantom created showed an accuracy of 1 mm and was well suited for all measurements. With the anesthesia unit attached to the custom made treatment couch the system is ideal for the radiation treatment of small laboratory animals like mice. It was feasible to shrink the field size of an industrial X-ray tube from whole animal irradiation to precise partial body irradiation of small laboratory animals. Even smaller secondary collimator sizes than 10 by 10 mm 2 are feasible with adequate secondary collimator inserts. Our custom made water phantom was well suited for the basic dosimetry of the X-ray tube.

  14. Body composition in hemodialysis patients measured by dual-energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Stenver, Doris Irene; Gotfredsen, Arne; Hilsted, J

    1995-01-01

    Dual-energy X-ray absorptiometry (DXA) measures three of the principal components of the body: fat mass, lean soft-tissue mass (comprising muscle, inner organs, and the body water), and the bone mineral content. The purpose of this study was to test the estimation capacity of DXA when it is applied...... and reduction in fat-free mass (lean soft-tissue mass plus bone mineral content) was observed by DXA. The estimation of the fat-free mass was independent of the amount of fluid loss. No significant differences in variance between the data obtained before and after the dialysis were observed. We conclude...

  15. Total reflection x-ray analysis of metals in blood samples

    International Nuclear Information System (INIS)

    Nakamura, Takuya; Matsui, Hiroshi; Kawamata, Masaya

    2009-01-01

    The sample preparation for TXRF (total reflection X-ray fluorescence) quantitative analysis of trace elements in human blood samples was investigated. In the TXRF analysis, a solution sample is dropped and dried on a flat substrate, and then the dried residue is measured. In this case, the dried residue should be flat not to disturb X-ray total reflection on the substrate. In addition, it is required to simply measure the whole blood sample by TXRF method, although a serum is analyzed in many cases. Thus, we studied the optimum conditions of the sample preparation of the whole blood by adding the pure water to apply Hemolysis phenomenon, where blood cells are destroyed due to different of the osmotic pressure, leading to flat residue. It was found that the best S/B ratio was obtained when the whole blood was diluted 8 times with pure water. Moreover, it was investigated the influence of the surface chemical condition of the glass substrate on the shape of the dried reside of the blood sample. When the surface of the glass substrate was hydrophilic, the shape of the dried residues was not uniform, as a result, the quantitative data of TXRF analysis gave a large deviation. On the other hand, when the surface of the glass was hydrophobic, the shape of the residue was almost uniform, as a result, a good reproducibility was obtained. Another problem was an outer ring of the dried residue of the blood. This uneven ring absorbs the primary X-rays, caused to low determined quantitative data. Thus, we tried the heating way of the dropped blood sample at a high temperature of 200 degrees. In this case, the blood sample was dried immediately, and a flat homogeneous dried residue was obtained without the outer ring. Using the optimized conditions for sample preparation, human blood sample was quantitatively measured by TXRF and ICP-AES. A good agreement was obtained in TXRF and ICP-AES determinations; however, the measurement of Cl and Br will be an advantage of TXRF, because

  16. STUDY OF TIME LAPSE IN FOREIGN BODY ASPIRATION IN RELATION TO CHEST X - RAY AND TYPE OF FOREIGN BODY

    Directory of Open Access Journals (Sweden)

    Salma

    2015-10-01

    Full Text Available INTRODUCTI ON: Foreign body aspiration in pediatrics is a potentially fatal accident which will continue until children explore their surroundings with their hand and mouth. Pediatric aspirations will persist until mankind exists. Not all foreign body aspirations are witnessed hence chances of delay in diagnosing an aspiration are high. Delay in diagnosis depends on site and character of foreign body aspirated. The chest x - ray findings and type of foreign body extracted vary depending on the duration the foreign body remains in airway . OBJECTIVE: To study the X - ray finding in pediatric airway aspiration and its relation to time lapse, the type and site of lodgment of foreign body extracted via bronchoscopy. The type of foreign body in relation to time lapse in aspiration. MATERIAL AND METHODS: This was a prospective study done in Bapuji child health institute and research center, JJM Medical College, Davangere . History and pre bronchoscopy x - Ray finding were noted for 65 children who were posted for suspicious bronchoscopy from August 2011 to September 2013. 11 children were excluded from study as they showed no foreign body on bronchoscopy. Time lapse in aspir ation and seeking medical care was noted. The bronchoscopic findings regarding site of foreign body lodgment and type of foreign body were recorded. The type of foreign body and variation of x - ray picture in relation to time lapse in aspiration were noted. Data collected was analyzed using descriptive statistics. RESULT: It was observed that mean age was 28 months. About 80% of the cases were between 1 to 3 years age. 82% (n=53/54 were radio lucent foreign body, only 1.5% (n=1/54 were radio o paque. Site of lodgment of foreign body was right main bronchus in 48% (n=26/54, left main bronchus 46% (n=25/54 , tracheal 1.85% (n=1/54, subglottic 1.85% (n=1/54, carinal 1.85% (n=1/54, multiple site i.e. left bronchus +right bronchus+ carinal 1.85% (n=1/54. Groundnut was most common

  17. Whole-body X-ray scanner, TCT-700S/SORREL

    International Nuclear Information System (INIS)

    Abe, Katsuhide; Seki, Yasuhiro

    1989-01-01

    Toshiba has already marketed the top-of-the-line TCT-900S whole-body X-ray CT scanner, a standard series comprising the TCT-600S and TCT-600, and a basic scanner, the TCT-300S. Now, a new model has recently been developed, the TCT-600XT, in response to market demand for further enhanced models. The main considerations in the development of the TCT-600XT were improvements in image quality and patient throughput in order to maximize practical utility. With regard to image quality, a spatial resolution of 0.4mm has been achieved through the use of high-speed data acquisition (300 views per second) and by the adoption of Toshiba's proprietary X-ray tube/detector array shifting mechanism. In respect of patient throughput, a scan cycle of 12 seconds has been realized by shortening waiting time through the utilization of a 2 MHU X-ray tube and by the development of a high-speed reconstruction unit. In addition to the above improvements, Toshiba has developed a new recordable voice and scan system to maximize operational flexibility. (author)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of knee x-rays. A portable x-ray machine is a compact apparatus that can be taken ... of the body being examined, an x-ray machine produces a small burst of radiation that passes ...

  19. Colouration of medieval glass bracelets studied by total reflection x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Detcheva, Albena; Velinova, Ralitsa; Ivanova, Elisaveta; Jordanov, Juri; Karadjov, Metody

    2014-01-01

    The contents of 3d-transition metals (Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn) in fragments of medieval glass bracelets, found in the necropolis of Stambolovo and the castle of Mezek, Bulgaria, were determined by total reflection X-ray fluorescence (TXRF) analysis using gallium as internal standard. The samples were analysed as slurries in Triton X 114. The experimental parameters: grain size of the glass sample, concentrations of glass sample, Triton X114 and internal standard in the slurry, volume of the slurry aliquot taken for analysis, as well as the excitation time, were optimised. For method validation the certified reference material BAM-S005 Type A soda-lime glass was used. It was proven that the elements Co, Mn and Fe are responsible for colour generation in the investigated glass samples. The precision of the determinations is characterised by an RSD in the range 3–11%

  20. Impurities determination in uranium eluates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Bellavigna, Horacio J.; Eppis, Maria R.; Ramella, Jose L.

    1999-01-01

    The chemical control of impurities in nuclear materials is indispensable in order to assure an efficient operation of the reactors. The maximum concentration admitted depends of the elements and in most cases are in the parts per billion range. Conventional analytical methods require a pre-concentration treatment of the sample and a previous separation of the matrix (uranium). This paper investigates the use of the total reflection X-ray fluorescence as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range of 0.1 to 20 ng/ml for a 1000 seconds counting time. (author)

  1. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de

    2005-01-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g -1 (Rb), respectively. (author)

  2. Multielemental analysis in Brazilian cigarettes using total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Moreira, Silvana

    2005-01-01

    In order to identify major and trace elements in conventional and light Brazilian cigarettes, Total Reflection X-Ray Fluorescence with Synchrotron Radiation (SR-TXRF) was used. The fluorescence measurements were carried out at Brazilian Synchrotron Light Laboratory, Campinas - Sao Paulo. This technique enables detection limit is in the ngg -1 range, which is very useful in elemental tobacco smoke analysis, since it presents most of its elements at a trace level. The major elements identified in tobacco samples were: S, Cl, K, Ca, Mn, Fe and Cd, and the trace elements were: Ti, Cr, Ni, Cu, Zn, Br, Rb, Sr and Ba. However in tobacco smoke samples, there were only two major elements: K and Ca, the others were present a trace level. The rate transfer of tobacco to tobacco smoke was about 2.5 % for all elements studied. (author)

  3. Total radiation dosage from X-ray examinations in rheumatoid arthritis and other chronic skeletal diseases

    International Nuclear Information System (INIS)

    Baldursson, H.; Gustafsson, M.

    1977-01-01

    Young patients with rheumatoid arthritis and other chronic diseases of the skeleton are increasingly being operated on with replacement of major joints. The great number of associated X-ray examinations performed on these patients has caused some anxiety amongst orthopaedic surgeons. Two patients with juvenile rheumatoid arthritis have been studied. An attempt was made to calculate the total radiation dose to bone marrow and gonads. For lack of recommendations for the maximum permissible radiation dose to patients, the dose calculated has been compared with the maximum permissible dose of radiation workers, and with the dose limit for non-occupational irradiation of individuals. The yearly absorbed dose in these two patients is much lower than the maximum permissible dose of radiation workers and only slightly higher than the dose limit for non-occupational exposure of individuals. (author)

  4. Recent trends in total reflection X-ray fluorescence spectrometry for biological applications

    International Nuclear Information System (INIS)

    Szoboszlai, Norbert; Polgari, Zsofia; Mihucz, Victor G.; Zaray, Gyula

    2009-01-01

    This review is focused on the application of total reflection X-ray fluorescence (TXRF) spectrometry in the field of biological research. In the last decade, most papers were published by authors who applied laboratory-scale TXRF equipments. The application of synchrotron radiation as excitation source (SR-TXRF) shows a slowly increasing tendency. In the cited papers the micro-, trace and multielement capability of these TXRF techniques was demonstrated in the clinical and medical laboratory practice, as well as in various plant physiological studies. For speciation of elements in biological matrices, the TXRF was used as element specific detector following an off-line separation step (e.g., thin layer chromatography, high performance liquid chromatography), however, these off-line methods are not competitive with the on-line coupled HPLC-inductively coupled plasma mass spectrometry

  5. Total-reflection X-ray fluorescence: An alternative tool for the analysis of magnetic ferrofluids

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, R. [Servicio Interdepartamental de Investigacion (SIdI), Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, E-28049, Madrid (Spain)], E-mail: ramon.fernandez@uam.es; Costo, R.; Morales, M.P.; Bomati-Miguel, O.; Veintemillas-Verdaguer, S. [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049, Madrid (Spain)

    2008-12-15

    This work presents the first application of the total-reflection X-ray fluorescence (TXRF) to the compositional study of magnetic ferrofluids. With the aims of validating the best analytical conditions and also, limitations of the TXRF in the compositional study of these materials, an alternative empirical method, based in the use of angle-dependence TXRF (AD-TXRF) measurements, is proposed. Three kinds of ferromagnetic nanoparticles, with different morphologies, have been studied. The techniques of inductively coupled plasma mass spectrometry (ICP-MS) and inductively coupled plasma optical emission spectroscopy (ICP-OES) have been used to validate the TXRF results. In contrast with the plasma techniques, the developed TXRF procedure need not of previous chemical acid digestion. Additionally, two procedures of magnetic nanoparticles synthesis, co-precipitation and laser-pyrolysis, have been checked for the contaminants trace metals Zn, Mn and Cr. It has been found that the method of laser-pyrolysis produces nanoparticles of higher purity.

  6. Fundamental quantification procedure for total reflection X-ray fluorescence spectra analysis and elements determination

    International Nuclear Information System (INIS)

    Wegrzynek, D.; Holynska, B.

    1997-01-01

    A method for the determination of the concentrations of elements in particulate-like samples measured in total reflection geometry is proposed. In the proposed method the fundamental parameters are utilized for calculating the sensitivities of elements and an internal standard is used to account for the unknown mass per unit area of a sample and geometrical constant of the spectrometer. The modification of the primary excitation spectrum on its way to a sample has been taken into consideration. The concentrations of the elements to be determined are calculated simultaneously with the spectra deconvolution procedure. In the process of quantitative analysis the intensities of all X-ray peaks corresponding to K and L-series lines present in the analyzed spectrum are taken into account. (Author)

  7. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  8. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  9. Neonatal anthropometrics and body composition in obese children investigated by dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Lausten-Thomsen, Ulrik; Nielsen, Tenna Ruest Haarmark; Thagaard, Ida Näslund

    2014-01-01

    index (BFMI), and fat free mass index (FFMI) in obese children and the preceding in utero conditions expressed by birth weight, birth length, and birth weight for gestational age. The study cohort consisted of 776 obese Danish children (median age 11.6 years, range 3.6-17.9) with a mean Body Mass Index......UNLABELLED: Epidemiological and animal studies have suggested an effect of the intrauterine milieu upon the development of childhood obesity. This study investigates the relationship between body composition measured by dual energy X-ray absorptiometry expressed as body fat percent, body fat mass...... Standard Deviation Score (BMI SDS) of 2.86 (range 1.64-5.48) treated in our national referral centre. In a linear general regression model adjusted for age, gender, socioeconomic status, and duration of breastfeeding, we found the body fat percent, FFMI, and BFMI at the time of enrolment in childhood...

  10. Total reflection x-ray fluorescence spectrometers for multielemental analysis: status of commercial equipment

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    2000-01-01

    Multi-elemental analysis by total reflection x-ray fluorescence spectrometry has evolved during two decades. At the present there are commercial equipment available for the chemical analysis in all kind of biological and mineral samples. The electronic industry has also been benefited from the scientific and technological developments in the field of TXRF. The basic components of the spectrometers can be summarized as follow: a) excitation source; b) geometric arrangement (optics) for collimation and monochromatization of the primary radiation; c) x-ray detector; d) hardware and software for operation of the instrument, data acquisition and spectral deconvolution to determine the concentrations of the element present in the sample (quantitative analysis). As optional there are manufacturers offering the conventional 45 degrees geometry for direct excitation of bulky liquid or solid samples. Personal communications of the author and the commercial brochures available at the moment of writing this presentation have allowed to list the following type of components used in the TXRF spectrometers for multi-elemental analysis (the devices used in the electronic industry to analyze silicon wafers are excluded). Excitation: high power x-ray tube, output from 1300 to 2000 watts; metal ceramic low power-ray tube, output up to 50 watts. Different anodes are used but molybdenum, tungsten and copper are frequent. The excitation systems can be customized according to the requirements of the laboratory. Detector: Si-Li semi-conductor liquid nitrogen cooled; silicon solid state thermoelectrically cooled (silicon drift detector SDD and Si-PIN diode). Optics: multilayer monochromator of Si-W or Ni-C; double multilayer monochromator. Electronics: spectroscopy amplifier, analog to digital converter adapted to a PC compatible computer with software in Windows environment for the whole operation of the spectrometer and for qualy/quantitative analysis of samples are standards in the

  11. Total reflection X-ray fluorescence analysis of airborne silver nanoparticles from fabrics.

    Science.gov (United States)

    Menzel, Magnus; Fittschen, Ursula Elisabeth Adriane

    2014-03-18

    Ag nanoparticles (NPs) are usually applied to consumer products because of their antimicrobial properties, which are desired in fabrics for sportswear as well as cloth used for cleaning. Hazards to human health from airborne Ag NPs may occur when the NPs are inhaled. NPs are comparable in size to macromolecules and viruses and able to penetrate deep into the lungs, e.g., the alveoli, where they may cause damage to cells and tissue due to their large surface area. In this study, aerosols released form fabrics treated with Ag NPs were collected using a low pressure Berner impactor and analyzed with total reflection X-ray fluorescence (TXRF). We found that the Ag NPs are released primarily in the form of larger particles, mainly 0.13-2 μm, probably attached to fiber material. Using an electron micro probe, single particles could be identified. The detection of backscattered electrons suggests small spots on the particle consist of a heavier element, which most likely is Ag, although the signal in energy-dispersive X-ray spectroscopy (EDX) was below the lower limit of detection (LOD). To achieve LODs necessary for Ag determination, Ar peaks were eliminated by a nitrogen atmosphere provided by the "Picofox-box". This enables linear calibration and quantification of Ag. The LOD was calculated at 0.2 ng (2.0 ppb). Following the TXRF and scanning electron microscopy (SEM)/EDX analysis, the aerosol samples were dissolved in nitric acid and analyzed with ICPMS to successfully confirm the results obtained by the TXRF measurements.

  12. Comparison of conventional and total reflection excitation geometry for fluorescence X-ray absorption spectroscopy on droplet samples

    International Nuclear Information System (INIS)

    Falkenberg, G.; Pepponi, G.; Streli, C.; Wobrauschek, P.

    2003-01-01

    X-ray absorption fine structure (XAFS) experiments in fluorescence mode have been performed in total reflection excitation geometry and conventional 45 deg. /45 deg. excitation/detection geometry for comparison. The experimental results have shown that XAFS measurements are feasible under normal total reflection X-ray fluorescence (TXRF) conditions, i.e. on droplet samples, with excitation in grazing incidence and using a TXRF experimental chamber. The application of the total reflection excitation geometry for XAFS measurements increases the sensitivity compared to the conventional geometry leading to lower accessible concentration ranges. However, XAFS under total reflection excitation condition fails for highly concentrated samples because of the self-absorption effect

  13. Evaluation of body simulator for chest and abdomen in digital X-ray equipment

    International Nuclear Information System (INIS)

    Soares, Sidney S.; Cardoso, Gabriela P.; Oliveira, Giovanni Antônio P.; Batista, Adriana S.M.; Pereira, Esther Lorrayne M.

    2017-01-01

    The use of body simulators to control the quality of X-ray images is a practice that guarantees the control of essential parameters for diagnosis by the technique. The evolution of the equipment, between the analogue, digital computerized radiology (CR) and direct radiography (DR), requires evaluation of the equivalence in grayscale, of simulators, for an adjustment according to the specific technology of obtaining the image. In this sense, the present work presents the evaluation of a body simulator with regard to the representation of mean values of signal, noise and contrast obtained in chest radiographs and panoramic of the abdomen. For the thorax the cardiac region was considered as simulation target and for the abdomen simulation of the liver and small intestine. We used a retrospective study of images obtained with X-ray equipment - CR system, in which the images were studied using the ImageJ program, generating a data catalog. These were subsequently compared with those obtained experimentally using gel filled polymer body simulator. For the validation of the simulator, it was observed the gel equivalence of filling of the polymer box required to reach the image parameters of the cataloged radiographs. The results are discussed as to the physical principles of radiation interaction with biological and equivalent tissues

  14. X-ray morphology of the eburnated vertebral body - diagnostic and differential diagnostic problems

    Energy Technology Data Exchange (ETDEWEB)

    Krug, B; Lorenz, R; Steinbrich, W

    1988-08-01

    1. Numerous diseases may become manifest as eburnated vertebral bodies, and hence the X-ray morphological sign of eburnation is an unspecific one. Isolated characteristics such as the involvement of one or several vertebrae, an intact vertebral space, a broadening of the paravertebral accompanying shadow, and the remaining radiological skeletal status enable narrowing down the differential diagnosis, although anamnesis and clinical findings will supply the main pointers. 2. In primary tumorous eburnations radiotherapy or chemotherapy will render an X-ray morphological assessment of therapeutic success impossible. 3. In primary diagnosis of an eburnated vertebral body it is possible to apply sonography. CT and MR as diagnostic tools step by step to narrow down the differential diagnosis by detecting or excluding pathological abdominal processes such as liver or lymphatic node metastases, paravertebral or intraspinal soft-part dense space-occupying growths or bone infiltration, but it will only rarely be possible to classify the phenomenon properly as being caused by a well-defined process, even if CT and MR are employed.

  15. Direct EUV/X-Ray Modulation of the Ionosphere During the August 2017 Total Solar Eclipse

    Science.gov (United States)

    Mrak, Sebastijan; Semeter, Joshua; Drob, Douglas; Huba, J. D.

    2018-05-01

    The great American total solar eclipse of 21 August 2017 offered a fortuitous opportunity to study the response of the atmosphere and ionosphere using a myriad of ground instruments. We have used the network of U.S. Global Positioning System receivers to examine perturbations in maps of ionospheric total electron content (TEC). Coherent large-scale variations in TEC have been interpreted by others as gravity wave-induced traveling ionospheric disturbances. However, the solar disk had two active regions at that time, one near the center of the disk and one at the edge, which resulted in an irregular illumination pattern in the extreme ultraviolet (EUV)/X-ray bands. Using detailed EUV occultation maps calculated from the National Aeronautics and Space Administration Solar Dynamics Observatory Atmospheric Imaging Assembly images, we show excellent agreement between TEC perturbations and computed gradients in EUV illumination. The results strongly suggest that prominent large-scale TEC disturbances were consequences of direct EUV modulation, rather than gravity wave-induced traveling ionospheric disturbances.

  16. Collection of airborne particulate matter for a subsequent analysis by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bayer, H.; Bohlen, A. von; Schmeling, M.; Klockow, D.

    1995-01-01

    The collection of airborne particulate matter by filtration and impaction was adapted to total reflection X-ray fluorescence analysis (TXRF). Cellulose nitrate filters were used for collecting in a Berner impactor. Single filter spots were punched out, placed on quartz-glass carriers, dissolved by tetrahydrofuran and re-precipitated prior to element determinations by TXRF. In a Battelle-type impactor, airborne dust was collected on Plexiglass carriers coated with medical Vaseline. The loaded carriers were directly analyzed by TXRF. In both cases, quantification was simply performed by the addition of an internal standard after sampling. Impactors were made of a suitable material in order to investigate high blank values, collection losses and memory effects. It could be shown that stainless steel, even coated with TiN, is less suitable and should be avoided as an impactor material. Although aluminum is partly recommendable, titanium and the polymer Makrolon are quite appropriate. By using an impactor made of these materials, a reliable multielement determination in airborne dust is made possible with low detection limits as low as 1 ng/m 3 and a satisfactory repeatability of a few %. Short sampling times of only 1 h or less can be realized. The total procedure is simple and time-saving, and can be recommended for routine investigations of airborne particulate matter. (author)

  17. Synchrotron Radiation Total Reflection X-ray Fluorescence Spectroscopy for Microcontamination Analysis on Silicon Wafer Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Takaura, Norikatsu

    1997-10-01

    As dimensions in state-of-the-art CMOS devices shrink to less than 0.1 pm, even low levels of impurities on wafer surfaces can cause device degradation. Conventionally, metal contamination on wafer surfaces is measured using Total Reflection X-Ray Fluorescence Spectroscopy (TXRF). However, commercially available TXRF systems do not have the necessary sensitivity for measuring the lower levels of contamination required to develop new CMOS technologies. In an attempt to improve the sensitivity of TXRF, this research investigates Synchrotron Radiation TXRF (SR TXRF). The advantages of SR TXRF over conventional TXRF are higher incident photon flux, energy tunability, and linear polarization. We made use of these advantages to develop an optimized SR TXRF system at the Stanford Synchrotron Radiation Laboratory (SSRL). The results of measurements show that the Minimum Detection Limits (MDLs) of SR TXRF for 3-d transition metals are typically at a level-of 3x10{sup 8} atoms/cm{sup 2}, which is better than conventional TXRF by about a factor of 20. However, to use our SR TXRF system for practical applications, it was necessary to modify a commercially available Si (Li) detector which generates parasitic fluorescence signals. With the modified detector, we could achieve true MDLs of 3x10{sup 8} atoms/cm{sup 2} for 3-d transition metals. In addition, the analysis of Al on Si wafers is described. Al analysis is difficult because strong Si signals overlap the Al signals. In this work, the Si signals are greatly reduced by tuning the incident beam energy below the Si K edge. The results of our measurements show that the sensitivity for Al is limited by x-ray Raman scattering. Furthermore, we show the results of theoretical modeling of SR TXRF backgrounds consisting of the bremsstrahlung generated by photoelectrons, Compton scattering, and Raman scattering. To model these backgrounds, we extended conventional theoretical models by taking into account several aspects particular

  18. Investigation of polyelectrolytes by total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Varga, I.; Nagy, M.

    2000-01-01

    Water soluble polyelectrolyte samples containing mono-, bi- and trivalent metal ions were investigated without any pretreatment. Acid digestion of linear polymers may lead to a product insoluble in water so the digestion has to be avoided. The aim of this paper was the determination of analytical characteristics and limitations of the total reflection x-ray fluorescence (TXRF) analysis for poly (vinylalcohol-vinylsulphate) salts and poly (acrylic acid, acrylamide) copolymers containing the following cations: K + , Cs + , Ba 2+ , Cu 2+ and La 3+ . On the basis of our results efficiency of ion-exchange during preparation of polyelectrolytes and stoichiometry of the end-product were determined. TXRF results were compared with data gained by inductively coupled plasma atomic emission spectrometry (ICP-AES) measurements except in the case of Cs + which has poor sensitivity in ICP-AES. Good agreement was found between the results of the two techniques and calculations from titrimetric data. Concentration of Li + and Mg 2+ in polymer samples was measured by ICP-AES. In majority of cases film-like dry residues of aqueous solutions of polyelectrolytes can be characterized by homogeneous spatial distribution of metal ions within the organic matrix. This is because the migration of the ions is hindered during drying process. Determination of metals in polyelectrolyte films by TXRF is quite ideal as model for analysis of plant, animal or human tissues which is a frequent task in environmental and inorganic biomedical analytical chemistry. (author)

  19. Synchrotron radiation total reflection x-ray fluorescence analysis; of polymer coated silicon wafers

    International Nuclear Information System (INIS)

    Brehm, L.; Kregsamer, P.; Pianetta, P.

    2000-01-01

    It is well known that total reflection x-ray fluorescence (TXRF) provides an efficient method for analyzing trace metal contamination on silicon wafer surfaces. New polymeric materials used as interlayer dielectrics in microprocessors are applied to the surface of silicon wafers by a spin-coating process. Analysis of these polymer coated wafers present a new challenge for TXRF analysis. Polymer solutions are typically analyzed for bulk metal contamination prior to application on the wafer using inductively coupled plasma mass spectrometry (ICP-MS). Questions have arisen about how to relate results of surface contamination analysis (TXRF) of a polymer coated wafer to bulk trace analysis (ICP-MS) of the polymer solutions. Experiments were done to explore this issue using synchrotron radiation (SR) TXRF. Polymer solutions were spiked with several different concentrations of metals. These solutions were applied to silicon wafers using the normal spin-coating process. The polymer coated wafers were then measured using the SR-TXRF instrument set-up at the Stanford Synchrotron Radiation Laboratory (SSRL). Several methods of quantitation were evaluated. The best results were obtained by developing calibration curves (intensity versus ppb) using the spiked polymer coated wafers as standards. Conversion of SR-TXRF surface analysis results (atoms/cm 2 ) to a volume related concentration was also investigated. (author)

  20. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-01-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2 O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different (α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g -1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  1. Total porosity of carbonate reservoir rocks by X-ray microtomography in two different spatial resolutions

    International Nuclear Information System (INIS)

    Nagata, Rodrigo; Appoloni, Carlos R.; Marques, Leonardo C.; Fernandes, Celso P.

    2011-01-01

    Carbonate reservoir rocks contain more than 50% of world's petroleum. To know carbonate rocks' structural properties is quite important to petroleum extraction. One of their main structural properties is the total porosity, which shows the rock's capacity to stock petroleum. In recent years, the X-ray microtomography had been used to analyze the structural parameters of reservoir rocks. Such nondestructive technique generates images of the samples' internal structure, allowing the evaluation of its properties. The spatial resolution is a measurement parameter that indicates the smallest structure size observable in a sample. It is possible to measure one sample using two or more different spatial resolutions in order to evaluate the samples' pore scale. In this work, two samples of the same sort of carbonate rock were measured, and in each measurement a different spatial resolution (17 μm and 7 μm) was applied. The obtained results showed that with the better resolution it was possible to measure 8% more pores than with the poorer resolution. Such difference provides us with good expectations about such approach to study the pore scale of carbonate rocks. (author)

  2. Multielement analysis of aerosol samples by X-ray fluorescence analysis with totally reflecting sample holders

    International Nuclear Information System (INIS)

    Ketelsen, P.; Knoechel, A.

    1984-01-01

    Aerosole samples on filter support were analyzed using the X-ray flourescence analytical method (Mo excitation) with totally reflecting sample carrier (TXFA). Wet decomposition of the sample material with HNO 3 in an enclosed system and subsequent sample preparation by evaporating an aliquot of the solution on the sample carrier yields detection limits up to 0.3 ng/cm 2 . The reproducibilities of the measurements of the elements K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb lie between 5 and 25%. Similar detection limits and reproducibilities are obtained, when low-temperature oxygen plasma is employed for the direct ashing of the homogenously covered filter on the sample carrier. For the systematic loss of elements both methods were investigated with radiotracers as well as with inactive techniques. A comparison of the results with those obtained by NAA, AAS and PIXE shows good agreement in most cases. For the bromine determination and the fast coverage of the main elements a possibility for measuring the filter membrane has been indicated, which neglects the ashing step. The corresponding detection limits are up to 3 ng/cm 2 . (orig.) [de

  3. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Davila, E.G. de; Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K α-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  4. Characterization and classification of spirituous beverages by total reflection x-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Davila, E.G. de [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, cabudare, Edo. Lara (Venezuela); Lue-Meru, M P; Capote, T [Univerisdad Centroccidental Lisandro Alvarado, Decanato de Agronomia, Dpto. de Quimica y Suelos. Nucleo Tarabana, Cabudare, Edo. Lara (Venezuela); Universidad Simon Bolivar, Dpto. de Quimica, Lab. Espectroscopia Atomica, Sartenejas, Baruta, Edo. Miranda (Venezuela); Greaves, E [Universidad Simon Bolivar, Dpto. de Fisica, Sartenejas, Baruta, Edo. Miranda (Venezuela)

    2000-07-01

    The total reflection x-ray fluorescence (TXRF) technique was applied for the multi-elemental analysis of spirituous beverages like rum, cocuy (typical spirituous beverage in Venezuela), whiskey and wine, in order to classify the samples by product processing and geographical origin by chemometric analysis. Special attention was paid to the cocuy samples, since there is a lack of quality control of this beverage, mainly due to the home-made product processing. The use of the Compton peak information was evaluated for the determination of organic content in samples. In the specifically case of cocuy samples the Compton peak area was correlated to the ash content for detection of adulteration with sugar syrup. Cocuy samples were also analyzed using gas chromatography, for pH, acidity, ash content and refractometry, in order to develop the recognition pattern. The TXRF analysis was carried out in a Canberra spectrometer, using the K {alpha}-line of a Motube, by a direct procedure previously developed. The analysis of the data was done by using principal components analysis and a confidence test. The results show that TXRF and chemometric analysis is a useful tool for quality control of spirituous beverages, not only concerning to metal content, but also in the evaluation of sugar and non volatile organic content. (author)

  5. Metal ions diffusion through polymeric matrices: A total reflection X-ray fluorescence study

    International Nuclear Information System (INIS)

    Boeykens, S.; Caracciolo, N.; D'Angelo, M.V.; Vazquez, C.

    2006-01-01

    This work proposes the use of X-ray fluorescence with total reflection geometry to explore the metal ions transport in aqueous hydrophilic polymer solutions. It is centered in the study of polymer concentration influence on ion diffusion. This subject is relevant to various and diverse applications, such as drug controlled release, microbiologic corrosion protection and enhanced oil recovery. It is anticipated that diffusion is influenced by various factors in these systems, including those specific to the diffusing species, such as charge, shape, molecular size, and those related to the structural complexity of the matrix as well as any specific interaction between the diffusing species and the matrix. The diffusion of nitrate salts of Ba and Mn (same charge, different hydrodynamic radii) through water-swollen polymeric solutions and gels in the 0.01% to 1% concentration ranges was investigated. The measurements of the metal concentration were performed by TXRF analysis using the scattered radiation by the sample as internal standard. Results are discussed according to different physical models for solute diffusion in polymeric solutions

  6. Total reflection X-ray fluorescence as a tool for food screening

    Science.gov (United States)

    Borgese, Laura; Bilo, Fabjola; Dalipi, Rogerta; Bontempi, Elza; Depero, Laura E.

    2015-11-01

    This review provides a comprehensive overview of the applications of total reflection X-ray fluorescence (TXRF) in the field of food analysis. Elemental composition of food is of great importance, since food is the main source of essential, major and trace elements for animals and humans. Some potentially toxic elements, dangerous for human health may contaminate food, entering the food chain from the environment, processing, and storage. For this reason the elemental analysis of food is fundamental for safety assessment. Fast and sensitive analytical techniques, able to detect major and trace elements, are required as a result of the increasing demand on multi-elemental information and product screening. TXRF is suitable for elemental analysis of food, since it provides simultaneous multi-elemental identification in a wide dynamic range of concentrations. Several different matrices may be analyzed obtaining results with a good precision and accuracy. In this review, the most recent literature about the use of TXRF for the analysis of food is reported. The focus is placed on the applications within food quality monitoring of drinks, beverages, vegetables, fruits, cereals, animal derivatives and dietary supplements. Furthermore, this paper provides a critical outlook on the developments required to transfer these methods from research to the industrial and analytical laboratories contexts.

  7. Visualization of femorotibial contact in total knee arthroplasty using X-ray fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Takaharu E-mail: yamazaki@image.med.osaka-u.ac.jp; Watanabe, Tetsu; Nakajima, Yoshikazu; Sugamoto, Kazuomi; Tomita, Tetsuya; Maeda, Daisuke; Sahara, Wataru; Yoshikawa, Hideki; Tamura, Shinichi

    2005-01-01

    The purpose of this study was to build a visualization technique of the femorotibial contact in fixed-bearing total knee arthroplasty (TKA) using X-ray fluoroscopy, and to apply this technique to a TKA patient during dynamic motion. In vivo kinametcis of the metallic knee implant was determined using a 2D/3D registration technique, which uses computer assisted design (CAD) model of the implant to estimate the 3D pose of radiopaque metallic femoral and tibial components from a single-plane fluoroscopic image. In fixed-bearing TKA, a 3D pose of radiolucent tibial polyethylene insert can be determined from the estimated pose of the tibial component. To visualize femorotibial contact, the proximity between surfaces of femoral component and tibial insert was calculated, and mapped onto the insert surface model. For the clinical application, dynamic states of contact on the tibial insert were observed including axial rotation and unilateral loading during knee flexion, and post-cam contact of posterior stabilized TKA. The present technique provided us new information and enabled us to better understand the relationship between in vivo knee kinematics and articular shape of the implant.

  8. Sample preparation for total reflection X-ray fluorescence analysis using resist pattern technique

    Science.gov (United States)

    Tsuji, K.; Yomogita, N.; Konyuba, Y.

    2018-06-01

    A circular resist pattern layer with a diameter of 9 mm was prepared on a glass substrate (26 mm × 76 mm; 1.5 mm thick) for total reflection X-ray fluorescence (TXRF) analysis. The parallel cross pattern was designed with a wall thickness of 10 μm, an interval of 20 μm, and a height of 1.4 or 0.8 μm. This additional resist layer did not significantly increase background intensity on the XRF peaks in TXRF spectra. Dotted residue was obtained from a standard solution (10 μL) containing Ti, Cr, Ni, Pb, and Ga, each at a final concentration of 10 ppm, on a normal glass substrate with a silicone coating layer. The height of the residue was more than 100 μm, where self-absorption in the large residue affected TXRF quantification (intensity relative standard deviation (RSD): 12-20%). In contrast, from a droplet composed of a small volume of solution dropped and cast on the resist pattern structure, the obtained residue was not completely film but a film-like residue with a thickness less than 1 μm, where self-absorption was not a serious problem. In the end, this sample preparation was demonstrated to improve TXRF quantification (intensity RSD: 2-4%).

  9. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2010-06-01

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO 3 and H 2O 2 (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ( α = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 μg g - 1 . A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of "Citrus Leaves" and a blank were treated in the same way.

  10. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers.

    Science.gov (United States)

    Schulz, B; Grossbach, A; Gruber-Rouh, T; Zangos, S; Vogl, Th J; Eichler, K

    2014-12-01

    To analyze the clinical value and radiation dose of plain x-rays and CT in examining patients suspected of ingesting drug-filled packets. Thirty-eight patients with suspected internal concealment of drug-filled packets who were examined with plain x-rays or CT or both were included in the study. CT studies were performed using low-dose and standard-dose techniques. All radiographic images were analysed by two radiologists regarding identification of the packets and estimating the effective radiation dose from standard- and low-dose CT versus conventional x-ray examinations. Descriptive calculations were made regarding the number and density of packs and radiation dosage. The diagnostic performance of both radiologists with standard- and low-dose CT was calculated by analysing differences in the mean number of packs found. Thirty-one patients were positively identified as body packers with an average of 13 packs (min: n = 1, max: n = 58, total: n = 390); seven patients were not concealing drug packets. X-ray images were taken of 24 patients prior to CT, thus allowing a direct comparison between the two methods. The correct diagnosis was made in 42%, in 33% the radiologists were uncertain, and in 25% of drug packets were either not or wrongly identified. X-ray imaging had a positive predictive value of 20% with a negative predictive value of 81%. A total of 55 CT examinations were performed on all patients with a mean effective dose of 2 mSv (low dose) versus 9.3 mSv (standard dose). The visibility of packets on low-dose CT images compared to high-dose CT was not reduced: the radiologists identified 385 and 381 of the packets, respectively, with no difference regarding the examination technique (p = 0.24 and p = 0.253, respectively). The radiodensity of all drug-filled packets at CT ranged from 26-292 HU (mean 181.2 HU). X-ray imaging of supposed body packers leads to a significant risk of diagnostic errors and additional need for CT. Instead, a single abdominal low

  11. Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children

    DEFF Research Database (Denmark)

    Tompuri, Tuomo T; Lakka, Timo A; Hakulinen, Mikko

    2015-01-01

    We compared InBody720 segmental multifrequency bioimpedance analysis (SMF-BIA) with Lunar Prodigy Advance dual-energy X-ray absorptiometry (DXA) in assessment of body composition among 178 predominantly prepubertal children. Segmental agreement analysis of body compartments was carried out...

  12. The feasibility of 10 keV X-ray as radiation source in total dose response radiation test

    International Nuclear Information System (INIS)

    Li Ruoyu; Li Bin; Luo Hongwei; Shi Qian

    2005-01-01

    The standard radiation source utilized in traditional total dose response radiation test is 60 Co, which is environment-threatening. X-rays, as a new radiation source, has the advantages such as safety, precise control of dose rate, strong intensity, possibility of wafer-level test or even on-line test, which greatly reduce cost for package, test and transportation. This paper discussed the feasibility of X-rays replacing 60 Co as the radiation source, based on the radiation mechanism and the effects of radiation on gate oxide. (authors)

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... conditions. Imaging with x-rays involves exposing a part of the body to a small dose of ... body. Once it is carefully aimed at the part of the body being examined, an x-ray ...

  14. Total and regional bone mineral content in healthy Spanish subjects by dual-energy X-ray absorptiometry

    International Nuclear Information System (INIS)

    Aguado Henche, S.; Rodriguez Torres, R.; Clemente de Arriba, C.; Gomez Pellico, L.

    2008-01-01

    This is an observational cross-sectional study. The aim of the present study was to describe and analyze patterns of change in total and regional bone mineral content in relation to age and gender in a sedentary Spanish sample population (from the Community of Madrid). The age range of the sample population was from birth to 80 years. One thousand one hundred twenty healthy subjects were recruited and divided into 16 groups according to age. Each subject underwent whole-body densitometry using dual-energy X-ray absorptiometry. An analysis was made of the amount of bone mineral content (BMC) in the whole body and in different regions: the head, trunk, upper limbs, and lower limbs. Gender differences in mean values for upper limbs and lower limbs are statistically significant between 16 and 70 years of age. For the head and trunk, the mean BMC values show the most significant gender differences between 16 and 25 years of age (p≤0.001). Total bone mineral content (TBMC) and TBMC-to-height ratio show significant gender differences between 16 and 70 years of age. In females, TBMC values increase up to 20 years of age and in males up to 25 years of age. We have determined an evolutionary normal pattern of bone mineral content in urban Spanish people. (orig.)

  15. Total and regional bone mineral content in healthy Spanish subjects by dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Aguado Henche, S.; Rodriguez Torres, R.; Clemente de Arriba, C.; Gomez Pellico, L. [Universidad de Alcala, Departamento de Anatomia y Embriologia Humana, Facultad de Medicina, Alcala de Henares, Madrid (Spain)

    2008-11-15

    This is an observational cross-sectional study. The aim of the present study was to describe and analyze patterns of change in total and regional bone mineral content in relation to age and gender in a sedentary Spanish sample population (from the Community of Madrid). The age range of the sample population was from birth to 80 years. One thousand one hundred twenty healthy subjects were recruited and divided into 16 groups according to age. Each subject underwent whole-body densitometry using dual-energy X-ray absorptiometry. An analysis was made of the amount of bone mineral content (BMC) in the whole body and in different regions: the head, trunk, upper limbs, and lower limbs. Gender differences in mean values for upper limbs and lower limbs are statistically significant between 16 and 70 years of age. For the head and trunk, the mean BMC values show the most significant gender differences between 16 and 25 years of age (p{<=}0.001). Total bone mineral content (TBMC) and TBMC-to-height ratio show significant gender differences between 16 and 70 years of age. In females, TBMC values increase up to 20 years of age and in males up to 25 years of age. We have determined an evolutionary normal pattern of bone mineral content in urban Spanish people. (orig.)

  16. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  17. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    Energy Technology Data Exchange (ETDEWEB)

    Mihucz, Victor G. [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); Moricz, Agnes M. [L. Eoetvoes University, Department of Chemical Technology and Environmental Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Kroepfl, Krisztina [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Szikora, Szilvia [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary); Tatar, Eniko [Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary); L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary); Parra, Lue Meru Marco [Universidad Centro-occidental Lisandro Alvarado, Decanato de Agronomia, Departamento de Quimica y Suelos Unidad de Analisis Instrumental, Apartado Postal 4076, Cabudare 3023 (Venezuela); Zaray, Gyula [Joint Research Group of Environmental Chemistry of Hungarian Academy of Sciences and L. Eoetvoes University, P. O. Box 32, H-1518 Budapest (Hungary) and Hungarian Satellite Centre of Trace Elements Institute to UNESCO, P. O. Box 32, H-1518 Budapest (Hungary) and L. Eoetvoes University, Department of Inorganic and Analytical Chemistry, P.O. Box 32, H-1518 Budapest (Hungary)]. E-mail: zaray@ludens.elte.hu

    2006-11-15

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods.

  18. Development of off-line layer chromatographic and total reflection X-ray fluorescence spectrometric methods for arsenic speciation

    International Nuclear Information System (INIS)

    Mihucz, Victor G.; Moricz, Agnes M.; Kroepfl, Krisztina; Szikora, Szilvia; Tatar, Eniko; Parra, Lue Meru Marco; Zaray, Gyula

    2006-01-01

    Rapid and low cost off-line thin layer chromatography-total reflection X-ray fluorescence spectrometry and overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods have been developed for separation of 25 ng of each As(III), As(V), monomethyl arsonic acid and dimethylarsinic acid applying a PEI cellulose stationary phase on plastic sheets and a mixture of acetone/acetic acid/water = 2:1:1 (v/v/v) as eluent system. The type of eluent systems, the amounts (25-1000 ng) of As species applied to PEI cellulose plates, injection volume, development distance, and flow rate (in case of overpressured thin layer chromatography) were taken into consideration for the development of the chromatographic separation. Moreover, a microdigestion method employing nitric acid for the As spots containing PEI cellulose scratched from the developed plates divided into segments was developed for the subsequent total reflection X-ray fluorescence spectrometry analysis. The method was applied for analysis of root extracts of cucumber plants grown in As(III) containing modified Hoagland nutrient solution. Both As(III) and As(V) were detected by applying the proposed thin layer chromatography/overpressured thin layer chromatography-total reflection X-ray fluorescence spectrometry methods

  19. Pediatric body composition analysis with dual-energy X-ray absorptiometry

    International Nuclear Information System (INIS)

    Helba, Maura; Binkovitz, Larry A.

    2009-01-01

    Pediatric applications of body composition analysis (BCA) have become of increased interest to pediatricians and other specialists. With the increasing prevalence of morbid obesity and with an increased awareness of anorexia nervosa, pediatric specialists are utilizing BCA data to help identify, treat, and prevent these conditions. Dual-energy X-ray absorptiometry (DXA) can be used to determine the fat mass (FM) and lean tissue mass (LTM), as well as bone mineral content (BMC). Among the readily available BCA techniques, DXA is the most widely used and it has the additional benefit of precisely quantifying regional FM and LTM. This review evaluates the strengths and limitations of DXA as a pediatric BCA method and considers the utilization of DXA to identify trends and variations in FM and LTM measurements in obese and anorexic children. (orig.)

  20. Pediatric body composition analysis with dual-energy X-ray absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Helba, Maura; Binkovitz, Larry A. [Nationwide Children' s Hospital, Department of Radiology, Columbus, OH (United States)

    2009-07-15

    Pediatric applications of body composition analysis (BCA) have become of increased interest to pediatricians and other specialists. With the increasing prevalence of morbid obesity and with an increased awareness of anorexia nervosa, pediatric specialists are utilizing BCA data to help identify, treat, and prevent these conditions. Dual-energy X-ray absorptiometry (DXA) can be used to determine the fat mass (FM) and lean tissue mass (LTM), as well as bone mineral content (BMC). Among the readily available BCA techniques, DXA is the most widely used and it has the additional benefit of precisely quantifying regional FM and LTM. This review evaluates the strengths and limitations of DXA as a pediatric BCA method and considers the utilization of DXA to identify trends and variations in FM and LTM measurements in obese and anorexic children. (orig.)

  1. Dual Energy X Ray Absorptiometry for Bone Mineral Density and Body Composition Assessment

    International Nuclear Information System (INIS)

    2010-01-01

    The IAEA assists Member States in their efforts to develop effective evidence based interventions to combat malnutrition in all its forms using nuclear techniques. The unique characteristics of nuclear techniques in nutrition, in particular stable isotope techniques and dual energy X ray absorptiometry (DXA), make these methods highly suitable for development and evaluation of interventions to address the double burden of malnutrition, i.e. 'undernutrition' and 'overnutrition', globally. This publication provides information on the theoretical background and practical application of state of the art methodology for bone mineral density (BMD) measurements and body composition assessment by DXA. The IAEA has contributed to the development and transfer of technical expertise in the use of DXA in Member States through support to national and regional nutrition projects via the technical cooperation programme and coordinated research projects addressing priority areas in nutrition. This book will be an important part of the IAEA's efforts to transfer technology and to contribute to capacity building in this field

  2. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, T; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat......, 5 males and 8 females, aged 34.2 years +/- SD 10.4, and 11 IDDM patients, 5 males, 6 females, aged 28.1 years +/- 7.3, diabetes duration 4.2 +/- 2.9 (1.0-9.9), were examined. The patients had no long-term diabetic complications and they had normal ophthalmoscopy and urine albumin excretion...

  3. Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients

    DEFF Research Database (Denmark)

    Rosenfalck, A M; Almdal, Thomas Peter; Gotfredsen, A

    1995-01-01

    Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat....... The agreement between FFM estimated by DXA and the other methods, expressed as mean difference +/- 2 SD was; for DXA vs. TBK, 0.09 +/- 6.26 and 0.50 +/- 5.26 kg for controls and IDDM patients respectively; DXA vs. TBW, -2.07 +/- 2.56 and -1.07 +/- 4.58 kg; DXA vs. Ucrea, -2.62 +/- 8.02 and 2.00 +/- 10.0 kg; DXA...

  4. Dynamic re-weighted total variation technique and statistic Iterative reconstruction method for x-ray CT metal artifact reduction

    Science.gov (United States)

    Peng, Chengtao; Qiu, Bensheng; Zhang, Cheng; Ma, Changyu; Yuan, Gang; Li, Ming

    2017-07-01

    Over the years, the X-ray computed tomography (CT) has been successfully used in clinical diagnosis. However, when the body of the patient to be examined contains metal objects, the image reconstructed would be polluted by severe metal artifacts, which affect the doctor's diagnosis of disease. In this work, we proposed a dynamic re-weighted total variation (DRWTV) technique combined with the statistic iterative reconstruction (SIR) method to reduce the artifacts. The DRWTV method is based on the total variation (TV) and re-weighted total variation (RWTV) techniques, but it provides a sparser representation than TV and protects the tissue details better than RWTV. Besides, the DRWTV can suppress the artifacts and noise, and the SIR convergence speed is also accelerated. The performance of the algorithm is tested on both simulated phantom dataset and clinical dataset, which are the teeth phantom with two metal implants and the skull with three metal implants, respectively. The proposed algorithm (SIR-DRWTV) is compared with two traditional iterative algorithms, which are SIR and SIR constrained by RWTV regulation (SIR-RWTV). The results show that the proposed algorithm has the best performance in reducing metal artifacts and protecting tissue details.

  5. Analysis of biological slurry samples by total x-ray fluorescence after in situ microwave digestion

    International Nuclear Information System (INIS)

    Lue-Meru, M.P.; Capote, T.; Greaves, E.

    2000-01-01

    Biological slurry samples were analyzed by total reflection x-ray fluorescence (TXRF) after an in situ microwave digestion procedure on the quartz reflector. This method lead to the removal of the matrix by the digestion and permits the enrichment of the analites by using sample amounts higher than those normally used in TXRF for the thin layer requirement since the organic matrix is removed. In consequence, the pre-concentration of sample is performed and the detection capability is increased by a quasi direct method. The samples analyzed were the international IAEA blood standard, the SRM bovine liver 1577-a standard and fresh onion tissues. Slurries were prepared in three ways: a.- weighing a sample amount on the reflector and adding suprapure nitric acid and internal standard followed by microwave digestion, b.-weighing a sample amount and water with an appropriate concentration of the internal standard in an Eppendorf vial, taking then an aliquot to the quartz reflector for microwave digestion with suprapure nitric acid, c.- weighing a sample amount of fresh tissue, homogenising with high speed homegenator to obtain a slurry sample which can be diluted in an ependorf vial with water an the internal standard. Then an aliquot is taken to the reflector for microwave digestion with suprapure nitric acid. Further details of sample preparation procedures will be discussed during presentation. The analysis was carried out in a Canberra spectrometer using the Kalpha lines of the Ag and Mo tubes. The elements Ca, K, Fe, Cu, Zn, Se, Mn, Rb, Br, Sr were determined. The effect of the preparation procedure was evaluated by the accuracy and precision of the results for each element and the percent of recovery. (author)

  6. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.; Braziewicz, J.

    2004-01-01

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called 'nondetects', i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for

  7. Total reflection X-ray fluorescence analysis of trace-elements in candies marketed in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T., E-mail: tmc@servidor.unam.m [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico D.F. 04510 (Mexico); Lartigue, J. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico); Navarrete, M. [Facultad de Quimica, Departamento de Quimica Inorganica y Nuclear. Universidad Nacional Autonoma de Mexico, Mexico, D.F. 04510 (Mexico); Tejeda, S. [National Institute of Nuclear Research. Ocoyoacac, Edo. de Mexico, 05045 (Mexico)

    2010-06-15

    Trace metals concentrations in food are significant for nutrition, due either to their nature or toxicity. Sweets, including chewing gum and candies, are not exactly a food, but they usually are unwearied consumed by children, the most vulnerable age-group to any kind of metal contamination in the food chain. The presence of relatively high concentrations of heavy metals such as Lead elicits concern since children are highly susceptible to heavy metals poisoning. Trace-metals concentrations were determined for six different flavors of a Mexican candy by means of Total X-ray Fluorescence Spectrometry. Triplicate samples of the various candy's flavours (strawberry, pineapple, lemon, blackberry, orange and chilli) were digested in 8 mL of a mix of supra-pure HNO{sub 3} and H{sub 2}O{sub 2} (6 mL: 2 mL) in a microwave oven MARS-X. Results show the presence of essential and toxic elements such as Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, and Pb. All metal concentrations were higher and significantly different ({alpha} = 0.05) in chilli candy, compared to other candy flavours. Lead concentration fluctuated in the range of 0.102 to 0.342 {mu}g g{sup -1}. A discussion about risk consumption and concentration allowed by Mexican and International Norms is made. As a part of the Quality Control Program, a NIST standard of 'Citrus Leaves' and a blank were treated in the same way.

  8. Combining mid infrared and total X-ray fluorescence spectroscopy for prediction of soil properties

    Science.gov (United States)

    Towett, Erick; Shepherd, Keith; Sila, Andrew; Aynekulu, Ermias; Cadisch, Georg

    2015-04-01

    Mid-infrared diffuse reflectance spectroscopy (MIR) can predict many soil properties but extractable nutrients are often predicted poorly. We evaluated the potential of MIR and total elemental analysis using total X-ray fluorescence spectroscopy (TXRF), both individually and combined, to predict results of conventional soil tests. Total multi-elemental analysis provides a fingerprint of soil mineralogy and could predict some soil properties and help improve MIR predictions. A set of 700 georeferenced soil samples associated with the Africa Soil Information Service (AfSIS) (www.africasoils.net) from 44 stratified randomly-located 100-km2 sentinel sites distributed across sub-Saharan Africa were analysed for physico-chemical composition using conventional reference methods, and compared to MIR and TXRF spectra using the Random Forests regression algorithm and an internal out-of-bag validation. MIR spectra resulted in good prediction models (R2 >0.80) for organic C and total N, Mehlich-3 Ca and Al, and pH. To test the combined spectroscopic approach, TXRF element concentration data was included as a property predictor along with the first derivative of MIR spectral data using the RF algorithm. Including TXRF did not improve prediction of these properties. TXRF was poorer (R2 0.86) as these elements are not directly determined with TXRF, however the variance explained is still quite high and may be attributable to TXRF signatures relating to mineralogy correlated with protection of soil organic matter. TXRF model for Mehlich-3 Al had excellent prediction capability explaining 81% of the observed variation in extractable Al content and was comparable to that of MIR (R2 = 0.86). However, models for pH and Mehlich-3 exchangeable Ca exhibited R2 values of 0.74 and 0.79 respectively and thus had moderate predictive accuracy, compared to MIR alone with R2 values of 0.82 and 0.84 respectively. Both MIR and TXRF methods predicted soil properties that relate to nutrient

  9. Modelling of a total reflection X-ray fluorescence (TXRF) system ...

    African Journals Online (AJOL)

    The simulation of the different stages involved in x-ray fluorescence emissions was carried out by writing a suite of computer programs using FORTRAN programming language. These computer simulated XRF stages were then integrated together to generate a general robust model which was run with the digital visual ...

  10. A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.

    Science.gov (United States)

    Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George

    2017-01-01

    To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and

  11. A study of percentage body fat in children via dual energy X-ray absorptiometry (DEXA)

    International Nuclear Information System (INIS)

    Kawano, Shoji; Yagi, Shinichi; Fujino, Mitsuyoshi; Tanaka, Hiroyuki; Morita, Tetsuro; Fukunaga, Masao

    1994-01-01

    Percentage body fat was measured using dual energy X-ray absorptiometry (DEXA), bioelectrical impedance analysis (BIA) and skin fold calipers on 26 children (nine in obesity group, 12 in healthy group and 5 in steroid treated group). Mean percent body fat did not differ significantly between methods in the whole subjects as well as the healthy group and the steroid treated group. However, the mean percent body fat using skin fold caliper was higher for the obesity group than the other two. The measurements of all cases in the obesity group by DEXA were higher than those of BIA. There were high correlations among the percent body fat obtained by each technique. According to the analysis of mean regional percent fat, the percent fat of legs was the highest in the healthy and steroid treated group, while there was no regional difference in the obesity group. It should be possible to classify each case in the obesity group into upper segment and lower segment obesity by DEXA. (author)

  12. The study of dual energy X-ray absorptiometry on body composition components in obesity

    International Nuclear Information System (INIS)

    Huang Zhongkui; Chen Wei; Long Liling; Li Xiaoyang

    2009-01-01

    Objective: To study the correlation of the bone mineral density (BMD) and the body composition components of body mass index (BMI), FAT and LEAN in Chinese obesity. Methods: There were 150 cases in obesity group diagnosed by BMI, including 75 males [ median age 46 years, mean weight (89.64 ± 8.33) kg] and 75 females [median age 45 years, mean weight (77.23 ± 6.85) kg]. There were 150 persons with normal BMI in the control group, including 75 males [(median age 47 years, mean weight (62.34 ± 5.72) kg] and 75 females [ median age 45 years, mean weight (50.16 ± 5.06) kg]. The body height and weight of 300 persons in two groups were measured respectively and ,simultaneously calculated the BMI. These data and the body composition parameters measured by the dual energy X-ray absorptiometry (DEXA) in these two groups were compared and analyzed. The data obtained used two-sample t-test analysis, bi-variable correlation used Pearson linear correlation analysis and multi-variable correlation used multiple linear regression analysis. Results: FAT of arms, legs trunk and total body of male cases in obesity group was (2.90 ± 0.57), (7.48 ± 1.46), (15.67 ± 3.05), (30.92 ± 5.94) kg respectively, FAT% was (30.9 ± 5.1)%, (30.6 ± 5.8)%, (37.3 ± 4.7)%, (35.1 ± 4.4)% respectively, it was significantly higher than that in control group [FAT was (1.12 ± 0.64), (3.27 ± 1.22), (6.71 ± 3.29), (11.61 ± 5.16) kg respectively, FAT% was (15.4 ± 4.8)%, (16.5 ± 5.0)%, (21.8 ± 5.8)%, (18.6 ± 5.3)% respectively], P 2 respectively, it was significantly higher than that in control group [ LEAN was (22.89 ± 1.68), (48.89 ± 3.72) kg respectively, BMD was (0.89 ± 0.07), (1.15 ± 0.06) g/cm 2 respectively], P 2 respectively, and there were no statistical significance compared with those in control group [LEAN was (5.99 ± 0.72), (16.83 ± 1.67) kg respectively, BMD was (0.90 ± 0.08), (1.29 ± 0.09) g/cm 2 respectively]. FAT of arms, legs, trunk and total body of females in

  13. Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis.

    Science.gov (United States)

    Messina, Carmelo; Monaco, Cristian Giuseppe; Ulivieri, Fabio Massimo; Sardanelli, Francesco; Sconfienza, Luca Maria

    2016-08-01

    Due to the tight relationship between bone and soft tissues, there has been an increased interest in body composition assessment in patients with secondary osteoporosis as well as other pathological conditions. Dual-energy X-ray absorptiometry (DXA) is primarily devoted to the evaluation of bone mineral status, but continuous scientific advances of body composition software made DXA a rapid and easily available technique to assess body composition in terms of fat mass and lean mass. As a result, the International Society for Clinical Densitometry (ISCD) recently developed Official Positions regarding the use of this technique for body composition analysis. According to ISCD paper, indications are mainly limited to three conditions: HIV patients treated with antiretroviral agents associated with a risk of lipoatrophy; obese patients undergoing treatment for high weight loss; patients with sarcopenia or muscle weakness. Nevertheless, there are several other interesting clinical applications that were not included in the ISCD position paper, such as body composition assessment in patients undergoing organ transplantation, pulmonary disease as well as all those chronic condition that may lead to malnutrition. In conclusion, DXA body composition offers new diagnostic and research possibilities for a variety of diseases; due to its high reproducibility, DXA has also the potential to monitor body composition changes with pharmacological, nutritional or physic therapeutic interventions. ISCD addressed and recommended a list of clinical condition, but the crescent availability of DXA scans and software improvements may open the use of DXA to other indication in the next future. This article provides an overview of DXA body composition indications in the management of secondary osteoporosis and other clinical indications in adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Body-weight and chromosome aberrations induced by X-rays in somatic cells of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Marco, A. de; Belloni, M.P.

    1976-01-01

    Body-weight has been shown to influence the final expression of genetic damage by X-rays in Drosophila melanogaster. If larvae of Drosophila were raised up to the third instar in media containing different amounts of the same nutrient and in different conditions of crowding a positive correlation was observed between body-weight and frequency of chromosome aberrations induced by a given dose of X-rays in the somatic cells of their nerve ganglia. This effect, present in both sexes, is most plausibly attributed to a different capacity of big and small larvae for repairing radiation damage. (orig.) [de

  15. Errors in the determination of the total filtration of diagnostic x-ray tubes by the HVL method

    International Nuclear Information System (INIS)

    Gilmore, B.J.; Cranley, K.

    1990-01-01

    Optimal technique and an analysis of errors are essential for interpreting whether the total filtration of a diagnostic x-ray tube is acceptable. The study discusses this problem from a theoretical viewpoint utilising recent theoretical HVL-total-filtration data relating to 10 0 and 16 0 tungsten target angles and 0-30% kilovoltage ripples. The theory indicates the typical accuracy to which each appropriate parameter must be determined to maintain acceptable errors in total filtration. A quantitative approach is taken to evaluate systematic errors in a technique for interpolation of HVL from raw attenuation curve data. A theoretical derivation is presented to enable random errors in HVL due to x-ray set inconsistency to be estimated for particular experimental techniques and data analysis procedures. Further formulae are presented to enable errors in the total filtration estimate to be readily determined from those in the individual parameters. (author)

  16. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  17. Characterization of urban air pollution by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Schmeling, Martina

    2004-01-01

    Besides photochemical smog, particulate air pollution is a constantly growing problem in urban areas. The particulate matter present in pollution events contains often toxic or health impacting elements and is responsible for low visibility, might be triggering respiratory diseases like asthma, and can play an important role in formation or duration of smog events. To characterize particulate pollution in two different cities, samples were taken during intensive field campaigns in Chicago, IL, in 2002 and Phoenix, AZ, in 2001. Both cities experience regularly photochemical smog events as well as particulate pollution, but show very different meteorological and topographical conditions. Therefore it is expected that the particulate composition varies significantly, providing information about different pollution forms. Sampling took place in both cases at elevated locations and had a temporal resolution of 1.5 h and 1 h, respectively. The samples were analyzed by total reflection X-ray fluorescence after digestion of the filter matrix. As expected the elemental composition of particulate matter varied between both cities substantially with Phoenix showing a higher abundance of crustal elements, and Chicago enrichment in anthropogenically produced ones. In both cities diurnal patterns were found, exerting maxima in the morning and minima in the early afternoon. The diurnal pattern was much more regularly and also more strongly pronounced in Phoenix. Phoenix's valley location permits for a more stable nocturnal boundary layer to build up during the night thus trapping particulates efficiently during this time, until mixing occurs in the early morning hours and the residual layer lifts. In Chicago, the diurnal variation was less extreme, but another pattern determines the situation with the lake breeze. The lake breeze corresponds to a shift in wind direction towards the east, i.e. from Lake Michigan during the late morning. It was found that certain elemental species

  18. The effect of surface texture on total reflection of neutrons and X-rays from modified interfaces

    DEFF Research Database (Denmark)

    Goldar, A.; Roser, S.J.; Hughes, A.

    2002-01-01

    X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length and the h......X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length...... and the height of the surface roughness are larger than the wavelength (at least 100 times bigger) of the incoming beam, the total reflection edge in the reflection profile becomes rounded. This technique allows direct analysis of the variation of the reflectivity pro le in terms of the structure of the surface...

  19. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    Energy Technology Data Exchange (ETDEWEB)

    Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Pepponi, G. [ITC-irst, Povo (Italy); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Jokubonis, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, A-1020 Vienna (Austria); Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, D-22603 Hamburg (Germany); Zaray, G. [Institute of Inorganic and Applied Chemistry, 3 EOTVOS Univ, Budapest (Hungary); Broekaert, J. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fittschen, U. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Peschel, B. [Institute of Anorganic and Applied Chemistry, University Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2006-11-15

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm{sup 2} active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm{sup 2} silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al{sub 2}O{sub 3}. No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are

  20. Recent results of synchrotron radiation induced total reflection X-ray fluorescence analysis at HASYLAB, beamline L

    International Nuclear Information System (INIS)

    Streli, C.; Pepponi, G.; Wobrauschek, P.; Jokubonis, C.; Falkenberg, G.; Zaray, G.; Broekaert, J.; Fittschen, U.; Peschel, B.

    2006-01-01

    At the Hamburger Synchrotronstrahlungslabor (HASYLAB), Beamline L, a vacuum chamber for synchrotron radiation-induced total reflection X-ray fluorescence analysis, is now available which can easily be installed using the adjustment components for microanalysis present at this beamline. The detector is now in the final version of a Vortex silicon drift detector with 50-mm 2 active area from Radiant Detector Technologies. With the Ni/C multilayer monochromator set to 17 keV extrapolated detection limits of 8 fg were obtained using the 50-mm 2 silicon drift detector with 1000 s live time on a sample containing 100 pg of Ni. Various applications are presented, especially of samples which are available in very small amounts: As synchrotron radiation-induced total reflection X-ray fluorescence analysis is much more sensitive than tube-excited total reflection X-ray fluorescence analysis, the sampling time of aerosol samples can be diminished, resulting in a more precise time resolution of atmospheric events. Aerosols, directly sampled on Si reflectors in an impactor were investigated. A further application was the determination of contamination elements in a slurry of high-purity Al 2 O 3 . No digestion is required; the sample is pipetted and dried before analysis. A comparison with laboratory total reflection X-ray fluorescence analysis showed the higher sensitivity of synchrotron radiation-induced total reflection X-ray fluorescence analysis, more contamination elements could be detected. Using the Si-111 crystal monochromator also available at beamline L, XANES measurements to determine the chemical state were performed. This is only possible with lower sensitivity as the flux transmitted by the crystal monochromator is about a factor of 100 lower than that transmitted by the multilayer monochromator. Preliminary results of X-ray absorption near-edge structure measurements for As in xylem sap from cucumber plants fed with As(III) and As(V) are reported. Detection

  1. Dual Energy X Ray Absorptiometry for Bone Mineral Density and Body Composition Assessment (Arabic Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The IAEA assists Member States in their efforts to develop effective evidence based interventions to combat malnutrition in all its forms using nuclear techniques. The unique characteristics of nuclear techniques in nutrition, in particular stable isotope techniques and dual energy X ray absorptiometry (DXA), make these methods highly suitable for development and evaluation of interventions to address the double burden of malnutrition, i.e. 'undernutrition' and 'overnutrition', globally. This publication provides information on the theoretical background and practical application of state of the art methodology for bone mineral density (BMD) measurements and body composition assessment by DXA. The IAEA has contributed to the development and transfer of technical expertise in the use of DXA in Member States through support to national and regional nutrition projects via the technical cooperation programme and coordinated research projects addressing priority areas in nutrition. This book will be an important part of the IAEA's efforts to transfer technology and to contribute to capacity building in this field. The publication was developed by an international group of experts and is intended for nutritionists, radiation technologists, researchers and health professionals using DXA for BMD measurements and body composition assessment.

  2. On the effect of small radiation doses: Desoxyribonucleic acid (DNA) synthesis and DNA repair of thymus, spleen, and bone marrow cells in the rat after fractionated total body X-ray irradiation. Zur Wirkung kleiner Strahlendosen: Desoxyribonukleinsaeure-(DNA-)Synthese und DNA-Reparatur von Thymus-, Milz- und Knochenmarkszellen der Ratte nach fraktionierter Ganzkoerperroentgenbestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Tempel, K.; Ehling, G. (Muenchen Univ. (Germany, F.R.). Inst. fuer Pharmakologie, Toxikologie und Pharmazie)

    1989-09-01

    After three to seven days following to fractionated total body X-ray irradiation (TBI) (four expositions with doses of 0.3 to 5.0 cGy per fraction at intervals of 24 hours), a maximum 50 percent stimulation of the semiconservative DNA synthesis (SDS) of spleen cells was measured in vitro. This was not dependent of the fact if an acute high-dose (400 and/or 800 cGy) unique irradiation was applied after the fractionated TBI at the moment of stimulation. A significant increase of {sup 3}H-thymidine incorporation into the DNA of bone marrow and thymus cells was only found when doses of 1.25 cGy per fraction had been used. After fractionated TBI with doses of {ge}5 cGy per fraction, an increase of DNA synthesis resistant to hydroxyurea ('unprogrammed' DNA synthesis, UDS) was demonstrated in spleen cells. The UV-simulated UDS decreased proportionately. The sedimentation of thymus, spleen, and bone marrow nucleoids in a neutral saccharose gradient gave no evidence of an increased DNA repair capacity after fractionated TBI. Whereas the SDS stimulation by fractionated TBI with small doses can be explained by a modified proliferation behavior of exposed cells, the UDS behavior of spleen cells after considerably higher radiation doses suggests regenerative processes correlated with an increased number of cells resistant to hydroxyurea and cells presenting an UV repair deficiency. These findings can be considered to be a further proof of the assumed immune-stimulating effect of small radiation doses. (orig.).

  3. Measurement of total calcium in neurons by electron probe X-ray microanalysis.

    Science.gov (United States)

    Pivovarova, Natalia B; Andrews, S Brian

    2013-11-20

    In this article the tools, techniques, and instruments appropriate for quantitative measurements of intracellular elemental content using the technique known as electron probe microanalysis (EPMA) are described. Intramitochondrial calcium is a particular focus because of the critical role that mitochondrial calcium overload plays in neurodegenerative diseases. The method is based on the analysis of X-rays generated in an electron microscope (EM) by interaction of an electron beam with the specimen. In order to maintain the native distribution of diffusible elements in electron microscopy specimens, EPMA requires "cryofixation" of tissue followed by the preparation of ultrathin cryosections. Rapid freezing of cultured cells or organotypic slice cultures is carried out by plunge freezing in liquid ethane or by slam freezing against a cold metal block, respectively. Cryosections nominally 80 nm thick are cut dry with a diamond knife at ca. -160 °C, mounted on carbon/pioloform-coated copper grids, and cryotransferred into a cryo-EM using a specialized cryospecimen holder. After visual survey and location mapping at ≤-160 °C and low electron dose, frozen-hydrated cryosections are freeze-dried at -100 °C for ~30 min. Organelle-level images of dried cryosections are recorded, also at low dose, by means of a slow-scan CCD camera and subcellular regions of interest selected for analysis. X-rays emitted from ROIs by a stationary, focused, high-intensity electron probe are collected by an energy-dispersive X-ray (EDX) spectrometer, processed by associated electronics, and presented as an X-ray spectrum, that is, a plot of X-ray intensity vs. energy. Additional software facilitates: 1) identification of elemental components by their "characteristic" peak energies and fingerprint; and 2) quantitative analysis by extraction of peak areas/background. This paper concludes with two examples that illustrate typical EPMA applications, one in which mitochondrial calcium analysis

  4. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers

    International Nuclear Information System (INIS)

    Schulz, B.; Grossbach, A.; Gruber-Rouh, T.; Zangos, S.; Vogl, Th. J.; Eichler, K.

    2014-01-01

    Aim: To analyze the clinical value and radiation dose of plain x-rays and CT in examining patients suspected of ingesting drug-filled packets. Materials and methods: Thirty-eight patients with suspected internal concealment of drug-filled packets who were examined with plain x-rays or CT or both were included in the study. CT studies were performed using low-dose and standard-dose techniques. All radiographic images were analysed by two radiologists regarding identification of the packets and estimating the effective radiation dose from standard- and low-dose CT versus conventional x-ray examinations. Descriptive calculations were made regarding the number and density of packs and radiation dosage. The diagnostic performance of both radiologists with standard- and low-dose CT was calculated by analysing differences in the mean number of packs found. Results: Thirty-one patients were positively identified as body packers with an average of 13 packs (min: n = 1, max: n = 58, total: n = 390); seven patients were not concealing drug packets. X-ray images were taken of 24 patients prior to CT, thus allowing a direct comparison between the two methods. The correct diagnosis was made in 42%, in 33% the radiologists were uncertain, and in 25% of drug packets were either not or wrongly identified. X-ray imaging had a positive predictive value of 20% with a negative predictive value of 81%. A total of 55 CT examinations were performed on all patients with a mean effective dose of 2 mSv (low dose) versus 9.3 mSv (standard dose). The visibility of packets on low-dose CT images compared to high-dose CT was not reduced: the radiologists identified 385 and 381 of the packets, respectively, with no difference regarding the examination technique (p = 0.24 and p = 0.253, respectively). The radiodensity of all drug-filled packets at CT ranged from 26–292 HU (mean 181.2 HU). Conclusion: X-ray imaging of supposed body packers leads to a significant risk of diagnostic

  5. 1. Latin American Workshop on Total Reflection X-Ray Fluorescence (TXRF) and its Applications: TARABANA 99. Programme and Abstracts

    International Nuclear Information System (INIS)

    Vegas C, Fredy; Greaves N, Eduardo; Marco P, Lue-Meru

    1999-01-01

    It concerns about the advances in Total Reflection X-Ray Fluorescence (TXRF) instrumentation; structure, characteristic and potential of TXRF equipment used for chemical multielemental survey; TXRF: an approach to nano analysis; microanalytical investigation of environmental samples by TXRF spectrometry; TXRF of low Z elements; assessment of serum selenium levels in 2 month old sucking calves using TXRF: A powerful method to investigate the elemental composition of spheroids; environmental applications of TXRF; use of modifiers for the elimination in situ of chlorides in the analysis of TXRF; experimental methodology and analysis spectra for the determination of mercury by means of TXRF using amalgamation with gold; multielemental analysis of human amniotic fluid by use of Total Reflection X-Ray Fluorescence and rutherford forward scattering; determination of metal in samples of handmade penca; determination of oligo elements, platinum and relationship Zn/Cu in samples of blood serum and urine in oncological pediatric patient [es

  6. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    International Nuclear Information System (INIS)

    Friedrich, S.; Li, L.; Ott, L.L.; Kolgani, Rajeswari M.; Yong, G.J.; Ali, Z.A.; Drury, O.B.; Ables, E.; Bionta, R.M.

    2006-01-01

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with ∼10 12 photons per ∼200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within (1- x ) Sr x MnO 3 sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response

  7. Extremity x-ray

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003461.htm Extremity x-ray To use the sharing features on this page, ... in the body Risks There is low-level radiation exposure. X-rays are monitored and regulated to provide the ...

  8. Proposal for electron beam induced remote sensing x-ray fluorescence investigation of minor bodies in the solar system

    International Nuclear Information System (INIS)

    Hrehuss, G.; Gombosi, T.I.; Naday, I.; Pogany, L.; Szegoe, K.

    1983-11-01

    The composition of the surface material of minor bodies in the solar system can be measured using a semiconductor soft x-ray spectrometer mounted on the space probe. The characteristic x-rays are excited by a 20 kV low current electron beam of a space-born electron gun. After the description of the main features of the technique, estimations on its sensitivity, supported by a model experiment, are given. The minimum fly-by distance to apply this method can be estimated as a few kilometers. (author)

  9. Whole body dual X-ray absorptiometry for bone mineral density and body composition using a flat panel detector

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Gonon, G.; Bordy, T.

    2003-01-01

    Whole-body dual-energy X-ray absorptiometry (DXA) systems are used for the determination of bone mineral density (BMD) but also for body composition estimates (lean mass and fat mass). The calculation is based on the difference in attenuation of body tissues for a low-energy of about 50 KeV and a high-energy of about 80-100 KeV. The measurement of dual-energy projections allows first to compute to the body composition in the non-bone area, and then to extrapolate the fat / lean ratio of soft tissue into the bone area in order to compute the BMD. Since detectors have limited area, a whole body examination requires a scan of the patient and a reconstruction process in order to build up a large field image from smaller radiographs. This reconstruction process must keep the quantitative value of the radiographs, and avoid any distortion which could be a consequence of the conic acquisition geometry. The cone angle is low (6 at maximum) and the large overlap between radiographs helps to reconstruct an image equivalent with a parallel-beam geometry. Scatter is corrected from the radiographs before reconstruction, as described in a previous paper ('Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry', SPIE Medical Imaging 2001, Medical Physics). We have developed an original reconstruction method dedicated to whole-body examinations which will be described. Thanks to the quasi-radiologic quality of the detector, reconstructed images are of very good quality and this makes the measurement of BMD and fat / lean masses easier. (author)

  10. Determination of solid surface composition by the X-ray fluorescence method under total external reflection with angular scanning

    International Nuclear Information System (INIS)

    Krasnolutskij, V.P.

    2000-01-01

    Possibilities of determination of composition of surface layers by X-ray fluorescence analysis under total reflection of incident radiation with angular scanning of a target are investigated. For the case of the GaAs target it is shown that the sensibility of this method is sufficient for a control of element composition in layer of thickness 1 nm. A simple method for solution of inverse task of analysis of a two component medium is considered [ru

  11. Pigment particles analysis with a total reflection X-ray fluorescence spectrometer: study of influence of instrumental parameters

    Energy Technology Data Exchange (ETDEWEB)

    Coccato, Alessia; Vandenabeele, Peter [Ghent University, Department of Archaeology, Ghent (Belgium); Vekemans, Bart; Vincze, Laszlo; Moens, Luc [Ghent University, Department of Analytical Chemistry, Ghent (Belgium)

    2016-12-15

    Total reflection X-ray fluorescence (TXRF) analysis is an excellent tool to determine major, minor and trace elements in minuscule amounts of samples, making this technique very suitable for pigment analysis. Collecting minuscule amounts of pigment material from precious works of art by means of a cotton swab is a well-accepted sampling method, but poses specific challenges when TXRF is to be used for the characterization of the unknown material. (orig.)

  12. Apparatus for the examination of a living body by X-rays or γ-rays

    International Nuclear Information System (INIS)

    Hounsfield, G.N.

    1975-01-01

    The apparatus utilizes x-rays or gamma-rays for the representation of the absorption coefficients of a specimen of locations in a level area of the interior of a body with highly different tissues. It consists of the radiation source and a collector with collimator for a narrow bundle of rays. Collector and radiation source on the one hand, and the body on the other hand, are movable relative to each other into various angle- and lateral positions. For this purpose, the collector and the radiation source are attached to a scanning frame relative to a hollow space, with the hollow space serving as a receptable for the body. The scanning frame is controlled in such a way that a lateral scanning motion takes place for each of a succession of rotary steps. From the lateral scanning motion a group of output signals is led away which corresponds to the penetration or absorption of adjacent bundle of rays. Successive groups are led away in accordance with successive rotary steps. A matrix is at hand for the storage of the output signals which reproduces the sectional plane. The output signals are administered to the corresponding matrix elements associated with the scanning path. Drift effects or disturbances which, for instance, can result in ring patterns, are thereby prevented. Furthermore, a store for the storage of impedance factors for intersection areas of the bundles of rays which are associated with the matrix element can be provided. A distributor distributes fault signals, as a function of the valencies of the impedance factors, onto the matrix elements. (HP) [de

  13. Detecting meaningful body composition changes in athletes using dual-energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Colyer, Steffi L; Roberts, Simon P; Thompson, Dylan; Stokes, Keith A; Bilzon, James L J; Salo, Aki I T; Robinson, Jonathan B

    2016-01-01

    Dual-energy x-ray absorptiometry (DXA) imaging is considered to provide a valid and reliable estimation of body composition when stringent scanning protocols are adopted. However, applied practitioners are not always able to achieve this level of control and the subsequent impact on measurement precision is not always taken into account when evaluating longitudinal body composition changes. The primary aim of this study was to establish the reliability of DXA in an applied elite sport setting to investigate whether real body composition changes can be detected. Additionally, the performance implications of these changes during the training year were investigated. Forty-eight well-trained athletes (from four diverse sports) underwent two DXA scans using a ‘real-world’ approach (with limited pre-scan controls), typically within 48 h, to quantify typical error of measurement (TEM). Twenty-five athletes underwent further scans, before and after specific training and competition blocks. ‘True’ body composition changes were evaluated using 2  ×  TEM thresholds. Twelve bob skeleton athletes also performed countermovement jump and leg press tests at each time point. Many ‘true’ body composition changes were detected and coincided with the primary training emphases (e.g. lean mass gains during hypertrophy-based training). Clear relationships (r  ±  90% CI) were observed between performance changes (countermovement jump and leg press) and changes in lean mass (0.53  ±  0.26 and 0.35  ±  0.28, respectively) and fat mass (−0.44  ±  0.27 and  −0.37  ±  0.28, respectively). DXA was able to detect real body composition changes without the use of stringent scanning controls. Associations between changes in body composition and performance demonstrated the potential influence of these changes on strength and power indices. (paper)

  14. Restoring efficiency of hemopoietic cell transplantation in a mouse lethally irradiated by a total exposure to X rays

    International Nuclear Information System (INIS)

    Doria, Gino

    1959-10-01

    This research thesis reports the study of possibility of treatments (or restoration) of a mouse which has been submitted to a lethal dose of X rays. More particularly, the author compared the restoring efficiency of bone marrow and fetal liver injected in a mouse which had been lethally irradiated by a total exposure to X rays. He also studied the functional status of the hemopoietic graft, and the emergence of the secondary disease in mice which had been as well lethally irradiated and then restored by injection of bone marrow and fetal liver. The author then addressed the influence of the induction of immune tolerance of the host with respect to the donor on the survival of a mouse lethally irradiated and restored by homologue bone marrow [fr

  15. Application of a portable total reflection x-ray fluorescence spectrometer to a trace elemental analysis of wines

    International Nuclear Information System (INIS)

    Kunimura, Shinsuke; Kawai, Jun

    2009-01-01

    A portable total reflection X-ray fluorescence (TXRF) spectrometer has been applied to a trace elemental analysis of wines. Sulfur, K, Mn, Fe, and Rb were detected. These five elements were quantified by using 1 ppm of Co as an internal standard. The quantified concentrations ranged from sub-ppm to several hundred ppm. Because of organic substances in wines, the scattering of the incident X-rays from the dry residues of wines becomes strong. Therefore, a high spectral background appears in TXRF spectra of wines. Because of this background, relative standard deviations of the quantified concentrations were from 4 to 28%. Although the high spectral background appeared in the TXRF spectra of the wines, a detection limit down to several tens of ppb was achieved. The present portable spectrometer can be applied to screening for trace elements in wines before an accurate and precise analysis using a large elemental analyzer. (author)

  16. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    International Nuclear Information System (INIS)

    Wang Zimian; Pierson, Richard N; Heymsfield, Steven B; Chen Zhao; Zhu Shankuan

    2010-01-01

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R ST value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R ST concept depends on the mass of each major element in the human body. The DXA R ST values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R ST value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body 40 K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R ST values. The DXA R ST values were strongly associated with the R ST values predicted from elemental content (r = 0.976, P ST to systematically exceed the DXA-measured R ST (mean ± SD, 1.389 ± 0.024 versus 1.341 ± 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 ± 12.0% versus 24.9 ± 11.1%, r = 0.983, P ST is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  17. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Energy Technology Data Exchange (ETDEWEB)

    Bulakci, Mesut, E-mail: mesutbulakci@yahoo.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Kalelioglu, Tuba, E-mail: tubakarsakarya@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Bulakci, Betul Bozkurt, E-mail: dr.betulbozkurt@gmail.com [Department of Family Medicine, Istanbul University, Istanbul Faculty of Medicine, 34390 Capa, Istanbul (Turkey); Kiris, Adem, E-mail: ademkiris@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey)

    2013-08-15

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing.

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  20. Insight into the structure of Pd/ZrO2 during the total oxidation of methane using combined in situ XRD, X.-ray absorption and Raman spectroscopy

    DEFF Research Database (Denmark)

    Grunwaldt, Jan-Dierk; van Vegten, Niels; Baiker, Alfons

    2009-01-01

    The structure of palladium during the total combustion of methane has been studied by a combination of the complementary in situ techniques X-ray absorption spectroscopy, Raman spectroscopy and X-ray diffraction. The study demonstrates that finely dispersed and oxidized palladium is most active f...

  1. Body composition of adult brachium by X-ray computed tomography

    International Nuclear Information System (INIS)

    Tanaka, Ryoji

    1988-01-01

    Sexual and age-related differences of body composition was analyzed in brachium by X-ray computed tomography. Subjects included 104 normal healthy adults (49 males and 55 females). The ages of the subjects ranged between 20 and 69. CT images were taken at the proximal third point, center and distal third point of the upper arm. The cross sectional areas of subcutaneous fat, muscular layer, intermuscular connective tissue and bone were measured in each image. For the muscular layer, each muscle was specified and measured. Results were related to sexual and age differences. 1) In males the muscular layer was the largest, followed in order by the subcutaneous fat and bone at all levels. In females, the subcutaneous fat was the largest, and the muscular layer was second. 2) Subcutaneous fat in the males increased in the 50s and 60s. The muscular layer of the males tended to decrease with age. On the contrary, subcutaneous fat in females increased with age. 3) At the proximal level in males, the brachial triceps reduced with age and the deltoid muscles reduced more. The female triceps and deltoid muscles showed slight age related changes in size. 4) At the other two levels, though the male triceps decreased remarkably with age, the female triceps did not. These muscles were similar in both sexes in the 60s. 5) The sexual difference in the size of each muscle diminished with the difference in motor activity of both sexes. Intermuscular variation was reduced to difference in the fiber type composition of each muscle. (author)

  2. Body composition of adult brachium by X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Ryoji

    1988-10-01

    Sexual and age-related differences of body composition was analyzed in brachium by X-ray computed tomography. Subjects included 104 normal healthy adults (49 males and 55 females). The ages of the subjects ranged between 20 and 69. CT images were taken at the proximal third point, center and distal third point of the upper arm. The cross sectional areas of subcutaneous fat, muscular layer, intermuscular connective tissue and bone were measured in each image. For the muscular layer, each muscle was specified and measured. Results were related to sexual and age differences. (1) In males the muscular layer was the largest, followed in order by the subcutaneous fat and bone at all levels. In females, the subcutaneous fat was the largest, and the muscular layer was second. (2) Subcutaneous fat in the males increased in the 50s and 60s. The muscular layer of the males tended to decrease with age. On the contrary, subcutaneous fat in females increased with age. (3) At the proximal level in males, the brachial triceps reduced with age and the deltoid muscles reduced more. The female triceps and deltoid muscles showed slight age related changes in size. (4) At the other two levels, though the male triceps decreased remarkably with age, the female triceps did not. These muscles were similar in both sexes in the 60s. (5) The sexual difference in the size of each muscle diminished with the difference in motor activity of both sexes. Intermuscular variation was reduced to difference in the fiber type composition of each muscle. (author).

  3. Many-body effects on the x-ray spectra of metals

    International Nuclear Information System (INIS)

    Satpathy, S.S.

    1982-01-01

    The effects of band structure, of a solid surface, of temperature, and of disorder on the many-electron x-ray spectra of metals are evaluated in a change-of-mean-field approximation using a one-dimensional nearest-neighbor tight-binding model of a metal. The x-ray spectral shapes are determined by both the band structure and the final-state interactions. The effect of the band being non-free-electron-like is not felt at the x-ray threshold, but away from it such effects are noticeable. When the core hole is created at the surface, the spectra at the edge exhibit a Nozieres-de Dominicis-type singularity with the appropriate surface phase-shifts. At energies away from the edge, the one-particle effects are prominent with the x-ray emission and absorption spectra closely reflecting the local one-electron density of states. The recoil spectrum of a Fermi sea at a non-zero temperature has less asymmetry than the zero-temperature case. It was found that at ordinary temperatures the reduction of the asymmetry due to the thermal distribution of one-electron states is not very significant. Finally, using a one-dimensional Anderson model, the effect of lattice disorder on the x-ray absorption spectra is studied for the first time. There are two effects: (1) the strong infrared divergence peak is gradually quenched as disorder is increased, and (2) the threshold is broadened because the threshold energies for absorption at different sites in the crystal depend on the varying local lattice environment. It is proposed that the x-ray spectra may be useful as a tool for studying the degree of electron localization in disordered many-electron systems

  4. [Body composition by dual-energy x-ray absorptiometry in women with fibromyalgia].

    Science.gov (United States)

    Lobo, Márcia Maria Marques Teles; Paiva, Eduardo dos Santos; Andretta, Aline; Schieferdecker, Maria Eliana Madalozzo

    2014-01-01

    To assess body composition in women with fibromyalgia (FM) comparing to the reference value for healthy women. Cross-sectional observational analytical study, with 52 women selected with Fibromyalgia, according American College of Rheumatology (ACR, 1990) criteria. The patients were selected in Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) and divided into two groups, 28 patients with a BMI (Body Mass Index) equal or higher (≥) than 25kg/m2 and 24 patients with BMI less or equal (≤) 24.99 kg/m2, subjected to physical examination for the count of tender points (TP) and completing the fibromyalgia impact questionnaire (FIQ). The assessment of body composition was performed by the Dual-Energy X-Ray Absorptiometry (DXA). The values of the fat mass percentage (MG %) found in the two groups were compared to the average percentage of MG by age and sex, described by Heward (2004). The mean age of the study groups was 47.8 ± 8.6 years, the FIQ score was 70.5 ± 18.6 and TP 16.2 ± 2.0. The mean BMI was 26.4 ± 4.1 kg/m2, and the amount of MG was 25.2 ± 7.8 kg and 39.5 ± 6.8%, and lean mass (LM) was 37 2 ± 3.7 kg and 60.4 ± 7.3%. In the group with BMI ≤ 25 kg/m2, the MG % was 33.8% (21.5 -42.4) and in the group with BMI ≥ 25 kg/m2 of the MG was 44.4% (37.6 -56.2). Both groups women with FM eutrophic as the overweight and obese group, presented higher reference MG% levels comparing with the standard levels for healthy women. Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  5. Ultrastructural changes in spermatogonia of Wistar strain rats following acute whole-body X-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hrehorovsky, M; Horak, J [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie

    1980-01-01

    Changes in spermatogonia ultrastructure in rats of Wistar strain after single whole-body X-ray irradiation with 6.4 mC.kg/sup -1/, 25.8 mC.kg/sup -1/ and 51.6 mC.kg/sup -1/ respectively, were studied. Intracellular spaces were found between spermatogonia enlarged, nuclear membranes were bent, the pheripheral teritories of chromation were electronoptically denser, the morphology of nucleoli was changed, cytoplasm was vacuolised, mitochondria were damaged, the vacuolar dilatation of agranular endoplasmic reticulum was evident and electronoptically empty vacuoles near the Golgi complex occured 48 hours after single whole-body X-ray irradiation. Qualitative changes in the ultrastructure of individual types of spermatogonia after individual exposures were similar.

  6. Background estimation in short-wave region during determination of total sample composition by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Simakov, V.A.; Kordyukov, S.V.; Petrov, E.N.

    1988-01-01

    Method of background estimation in short-wave spectral region during determination of total sample composition by X-ray fluorescence method is described. 13 types of different rocks with considerable variations of base composition and Zr, Nb, Th, U content below 7x10 -3 % are investigated. The suggested method of background accounting provides for a less statistical error of the background estimation than direct isolated measurement and reliability of its determination in a short-wave region independent on the sample base. Possibilities of suggested method for artificial mixtures conforming by the content of main component to technological concemtrates - niobium, zirconium, tantalum are estimated

  7. Analytical characterization of artists' pigments used in old and modern paintings by total-reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von; Moens, L.; Devos, W.

    1993-01-01

    The analytical characterization of artists' pigments is a most helpful tool for art history, conservation and restoration of paintings. A very gentle method of ultra-microsampling was developed that is especially applicable to paintings under restoration. It provides a sample mass of about 1 μg and is virtually non-destructive. This minute amount is sufficient for total-reflection X-ray fluorescence (TXRF) to determine most of those elements building inorganic pigments. The convenient and fast method was applied to oil paintings. Various pigments were identified and their mixing proportion was determined even quantitatively. (author)

  8. Trace elemental analysis of leaching solutions of hijiki seaweeds by a portable total reflection X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Liu, Ying; Imashuku, Susumu; Kawai, Jun

    2014-01-01

    A portable total reflection X-ray fluorescence spectrometer (TXRF) was used to analyze leaching solutions of hijiki seaweeds. S, Cl, K, Ca, Ti, Fe, Ni, As and Br were detected in the solutions. Arsenic quantification results were compared to those from ICP-AES. The TXRF quantification results of arsenic were not significantly different from those of ICP-AES, as two-way analysis of variance (ANOVA) method was applied to the significance test. This kind of small and high sensitive TXRF spectrometer can be used in food quality and environmental pollution investigation. (author)

  9. Elemental concentration in normal skin and fibroepithelial polip lesions by synchrotron radiation total reflection X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Soares, Julio C.A.C.R.; Canellas, Catarine G.L.; Lopes, Ricardo T.; Anjos, Marcelino J.

    2011-01-01

    In this work, the concentrations of trace elements were measured in acrochordon, a skin lesion also known as skin tag or fibroepithelial polyp, as well as in normal skin from the same patient. The samples were analysed by Synchrotron Radiation Total Reflection X- ray Fluorescence (SRTXRF) in the Synchrotron Light National Laboratory (LNLS) in Campinas/Sao Paulo-Brazil. The collection of lesion and healthy skin samples, including papillary dermis and epidermis, has involved 17 patients. It was evaluated the presence of P, S, Cl, K, Ca, Cr, Mn, Fe, Cu, Zn, Br and Rb in the paired samples, which were compared, and significant differences were found in some of them. (author)

  10. A method for thickness determination of thin films of amalgamable metals by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Bennun, L.; Greaves, E.D.; Barros, H.; Diaz-Valdes, J.

    2009-01-01

    A method for thickness determination of thin amalgamable metallic films by total-reflection X-ray fluorescence (TXRF) is presented. The peak's intensity in TXRF spectra are directly related to the surface density of the sample, i.e. to its thickness in a homogeneous film. Performing a traditional TXRF analysis on a thin film of an amalgamated metal, and determining the relative peak intensity of a specific metal line, the layer thickness can be precisely obtained. In the case of gold thickness determination, mercury and gold peaks overlap, hence we have developed a general data processing scheme to achieve the most precise results.

  11. Characterization of ancient coins with the use of total reflection x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ostachowicz, B.; Holynska, B.; Ostachowicz, J.; Haczewska, B.

    2000-01-01

    In this work the composition of silver coins from XI-XII centuries and a metal gorget from XVIII century have been studied. The beginnings of denarii (Sachsenpfennige) coinage might be linked with Saxony, whereas the end period of the production of those coins i.e. the last quarter of the XI th and beginning of the XII th centuries is connected also with Polish mints. The studied coins bearing the chivalric cross upon the reverse were minted by Wladyslaw Herman a Polish prince and his palatine Sieciech. Some of the coins were original ones, some other were forged, however the provenance of both types of coins was probably the same. The forged coins contained copper core covered with silver alloy. The TXRF module with molybdenum x-ray tube operated at 55 kV and 40 mA has been used for analysis of both types of coins. A quartz reflector was rubbed against a coin and then analyzed. Several metals were found and determined in the coins namely: zinc, copper, iron, lead and also trace concentrations of gold and mercury. A small piece of silver coin was also dissolved in nitric acid and a solution was analyzed by TXRF. The results showed good agreement with the data obtained by rubbing a coin. The gorget was made of gilded copper and decorated by paintings presenting a Holy Mary and Jesus Christ. The metal parts of the gorget was rubbed against quartz reflectors and analyzed. The concentration of major and minor elements in metal gives an important information for historian of art about technology of production and decoration of gorgets. The traces of mercury were found in the golden layer. This suggested that making Au-Hg amalgam followed by heating was used for covering a copper gorget with the layer of gold. (author)

  12. Prediction of Android and Gynoid Body Adiposity via a Three-dimensional Stereovision Body Imaging System and Dual-Energy X-ray Absorptiometry.

    Science.gov (United States)

    Lee, Jane J; Freeland-Graves, Jeanne H; Pepper, M Reese; Stanforth, Philip R; Xu, Bugao

    2015-01-01

    Current methods for measuring regional body fat are expensive and inconvenient compared to the relative cost-effectiveness and ease of use of a stereovision body imaging (SBI) system. The primary goal of this research is to develop prediction models for android and gynoid fat by body measurements assessed via SBI and dual-energy x-ray absorptiometry (DXA). Subsequently, mathematical equations for prediction of total and regional (trunk, leg) body adiposity were established via parameters measured by SBI and DXA. A total of 121 participants were randomly assigned into primary and cross-validation groups. Body measurements were obtained via traditional anthropometrics, SBI, and DXA. Multiple regression analysis was conducted to develop mathematical equations by demographics and SBI assessed body measurements as independent variables and body adiposity (fat mass and percentage fat) as dependent variables. The validity of the prediction models was evaluated by a split sample method and Bland-Altman analysis. The R(2) of the prediction equations for fat mass and percentage body fat were 93.2% and 76.4% for android and 91.4% and 66.5% for gynoid, respectively. The limits of agreement for the fat mass and percentage fat were -0.06 ± 0.87 kg and -0.11% ± 1.97% for android and -0.04 ± 1.58 kg and -0.19% ± 4.27% for gynoid. Prediction values for fat mass and percentage fat were 94.6% and 88.9% for total body, 93.9% and 71.0% for trunk, and 92.4% and 64.1% for leg, respectively. The three-dimensional (3D) SBI produces reliable parameters that can predict android and gynoid as well as total and regional (trunk, leg) fat mass.

  13. Design of a bolometer for total-energy measurement of the linear coherent light source pulsed X-ray laser

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, S. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States)]. E-mail: Friedrich1@llnl.gov; Li, L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Ott, L.L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Kolgani, Rajeswari M. [Department of Physics, Geosciences and Astronomy, Towson University, 8000 York Avenue, Towson MD 21252 (United States); Yong, G.J. [Department of Physics, Geosciences and Astronomy, Towson University, 8000 York Avenue, Towson MD 21252 (United States); Ali, Z.A. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Drury, O.B. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Ables, E. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States); Bionta, R.M. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore CA 94550 (United States)

    2006-04-15

    We are developing a cryogenic bolometer to measure the total energy of the linear coherent light source (LCLS) free electron X-ray laser to be built at the Stanford Linear Accelerator Center. The laser will produce ultrabright X-ray pulses in the energy range between 0.8 and 8 keV with {approx}10{sup 12} photons per {approx}200 fs pulse at a repeat interval of 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. The bolometer is designed to determine the total energy of each laser pulse to within <0.1%, taking into account thermal and mechanical stress to prevent melting in the LCLS beam due to its high energy density. We propose to use a magnetoresistive Nd{sub (1-} {sub x} {sub )}Sr {sub x} MnO{sub 3} sensor array at the metal-insulator transition, where the composition x is adjusted to produce the desired transition temperature. We discuss design considerations and material choices, and present numerical simulations of the thermal response.

  14. Total reflection X-ray fluorescence analysis of river waters in its stream across the city of Cordoba, in Argentina

    International Nuclear Information System (INIS)

    Valentinuzzi, M.C.; Sanchez, H.J.; Abraham, J.

    2006-01-01

    The aim of this work was to analyze the composition of river waters and to study their quality by detecting possible contaminants. The samples were taken at 32 points of the Suquia River in its stream across the city of Cordoba (in the Province of Cordoba, Argentina). The samples were analyzed with total reflection X-ray fluorescence (TXRF) using beam guides. Beam guides made of two Si plate reflectors were used as sample carriers and to guide the X-ray photons to the sample; the measurements were taken using the characteristic configuration that ensures the best excitation and detection conditions (in TXRF). The analyses were carried out by preconcentration of the water samples and by adding an internal standard (Gallium); small amounts of samples (30 μl) were deposited on the Si reflector plate and they were then analyzed in the total reflection regime. Spectra were analyzed with standard methods using conventional programs. The results show interesting behaviors of the concentration of trace elements along the river: elements of low atomic number (such as Ca, Cl, S, K) present higher concentrations as compared to high Z elements (such as Fe, Zn, Br, Sr); the concentrations of light elements follow a similar behavior along the stream, the same situation is observed in the set of elements with high atomic number. Some samples present high concentrations in certain elements indicating possible sources of contamination

  15. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  16. Differential and total M-shell X-ray production cross-sections of some selected elements between Au and U at 5.96 keV

    International Nuclear Information System (INIS)

    Ozdemir, Yueksel

    2007-01-01

    Differential M-shell X-ray production (MXRP) cross-sections for selected heavy elements between Au and U have been measured at 5.59 keV incident photon energy, respectively at seven angles varying from 120 o to 150 o a Si(Li) detector. The differential M-shell X-ray production cross-sections have been derived, using M-shell fluorescence yields, experimental total M X-ray production cross-sections and theoretical M-shell photoionization cross-sections. The differential M-shell X-ray production cross-sections have been compared with the semi-empirical fits. The measured differential M X-ray production cross-sections have been found within experimental error. Differential M X-ray production cross-section can be fitted to the Σ n a n Z n (n = 2) as a function of cos θ. Total M X-ray production cross-sections have been derived using the fitted values

  17. Quantum many-body effects in x-ray spectra efficiently computed using a basic graph algorithm

    Science.gov (United States)

    Liang, Yufeng; Prendergast, David

    2018-05-01

    The growing interest in using x-ray spectroscopy for refined materials characterization calls for an accurate electronic-structure theory to interpret the x-ray near-edge fine structure. In this work, we propose an efficient and unified framework to describe all the many-electron processes in a Fermi liquid after a sudden perturbation (such as a core hole). This problem has been visited by the Mahan-Noziéres-De Dominicis (MND) theory, but it is intractable to implement various Feynman diagrams within first-principles calculations. Here, we adopt a nondiagrammatic approach and treat all the many-electron processes in the MND theory on an equal footing. Starting from a recently introduced determinant formalism [Phys. Rev. Lett. 118, 096402 (2017), 10.1103/PhysRevLett.118.096402], we exploit the linear dependence of determinants describing different final states involved in the spectral calculations. An elementary graph algorithm, breadth-first search, can be used to quickly identify the important determinants for shaping the spectrum, which avoids the need to evaluate a great number of vanishingly small terms. This search algorithm is performed over the tree-structure of the many-body expansion, which mimics a path-finding process. We demonstrate that the determinantal approach is computationally inexpensive even for obtaining x-ray spectra of extended systems. Using Kohn-Sham orbitals from two self-consistent fields (ground and core-excited state) as input for constructing the determinants, the calculated x-ray spectra for a number of transition metal oxides are in good agreement with experiments. Many-electron aspects beyond the Bethe-Salpeter equation, as captured by this approach, are also discussed, such as shakeup excitations and many-body wave function overlap considered in Anderson's orthogonality catastrophe.

  18. Estimation of percentage body fat by dual-energy x-ray absorptiometry: evaluation by in vivo human elemental composition

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zimian; Pierson, Richard N [Obesity Research Center, St Luke' s-Roosevelt Hospital, Columbia University, College of Physicians and Surgeons, New York, NY (United States); Heymsfield, Steven B [Clinical Research, Metabolism, Merck Research Laboratories, Rahway, NJ (United States); Chen Zhao [Mel and Enid Zuckerman College of Public Health, University of Arizona, Tucson, AZ (United States); Zhu Shankuan, E-mail: zw28@columbia.ed [Obesity and Body Composition Research Center, Zhejiang University, School of Public Health, Hangzhou (China)

    2010-05-07

    Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R{sub ST} value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R{sub ST} concept depends on the mass of each major element in the human body. The DXA R{sub ST} values, however, have never been fully evaluated by measured human elemental composition. The present investigation evaluated the DXA R{sub ST} value by the total body mass of 11 major elements and the DXA %fat by the five-component (5C) model, respectively. Six elements (i.e. C, N, Na, P, Cl and Ca) were measured by in vivo neutron activation analysis, and potassium (i.e. K) by whole-body {sup 40}K counting in 27 healthy adults. Models were developed for predicting the total body mass of four additional elements (i.e. H, O, Mg and S). The elemental content of soft tissue, after correction for bone mineral elements, was used to predict the R{sub ST} values. The DXA R{sub ST} values were strongly associated with the R{sub ST} values predicted from elemental content (r = 0.976, P < 0.001), although there was a tendency for the elemental-predicted R{sub ST} to systematically exceed the DXA-measured R{sub ST} (mean {+-} SD, 1.389 {+-} 0.024 versus 1.341 {+-} 0.024). DXA-estimated %fat was strongly associated with 5C %fat (24.4 {+-} 12.0% versus 24.9 {+-} 11.1%, r = 0.983, P < 0.001). DXA R{sub ST} is evaluated by in vivo elemental composition, and the present study supports the underlying physical concept and accuracy of the DXA method for estimating %fat.

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in ...

  20. Accurate X-Ray Spectral Predictions: An Advanced Self-Consistent-Field Approach Inspired by Many-Body Perturbation Theory.

    Science.gov (United States)

    Liang, Yufeng; Vinson, John; Pemmaraju, Sri; Drisdell, Walter S; Shirley, Eric L; Prendergast, David

    2017-03-03

    Constrained-occupancy delta-self-consistent-field (ΔSCF) methods and many-body perturbation theories (MBPT) are two strategies for obtaining electronic excitations from first principles. Using the two distinct approaches, we study the O 1s core excitations that have become increasingly important for characterizing transition-metal oxides and understanding strong electronic correlation. The ΔSCF approach, in its current single-particle form, systematically underestimates the pre-edge intensity for chosen oxides, despite its success in weakly correlated systems. By contrast, the Bethe-Salpeter equation within MBPT predicts much better line shapes. This motivates one to reexamine the many-electron dynamics of x-ray excitations. We find that the single-particle ΔSCF approach can be rectified by explicitly calculating many-electron transition amplitudes, producing x-ray spectra in excellent agreement with experiments. This study paves the way to accurately predict x-ray near-edge spectral fingerprints for physics and materials science beyond the Bethe-Salpether equation.

  1. Total external reflection X-ray fluorescence analysis of protein-metal ion interactions in biological systems

    Science.gov (United States)

    Novikova, N. N.; Kovalchuk, M. V.; Yur'eva, E. A.; Konovalov, O. V.; Rogachev, A. V.; Stepina, N. D.; Sukhorukov, V. S.; Tsaregorodtsev, A. D.; Chukhrai, E. S.; Yakunin, S. N.

    2012-09-01

    This paper presents the results of an investigation into hemoglobin-based protein films that were formed on a liquid surface. X-ray standing wave measurements were performed at the ID 10 beamline of the European Synchrotron Radiation Facility (ESRF) and at the Langmuir station of the Kurchatov Synchrotron Radiation Source. It was found that the ability of the protein to bind metal ions is substantially increased due to the conformational rearrangements of protein macromolecules caused by various damaging effects. The elemental composition of protein preparations, which were isolated from children and adults with chronic metabolic diseases accompanied by endogenous intoxication, was analyzed. The results of the investigations offer evidence that an increase in the ligand-binding properties of the protein molecules, which was observed in model experiments using protein films, is a common trait and corresponds to in vivo processes accompanying metabolic disturbances in the body.

  2. Determination of total iron in iron ore by x-ray fluorescence analysis using the Compton effect: comparison with others analytical techniques

    International Nuclear Information System (INIS)

    Castilho, M.V. de; Oliveira, R.C.

    1991-01-01

    Total iron in iron ores is determines by X-ray fluorescence analysis method using the compton effect. The Bragg angle is determined for compton no-coherent scattering related to K alpha of Rhodium. This measurement procedure can be used for best fitting of analytical results in X-ray fluorescence, when compared with others methods used for results corrections. (M.V.M.)

  3. On revealing the vertical structure of nanoparticle films with elemental resolution: A total external reflection X-ray standing waves study

    Energy Technology Data Exchange (ETDEWEB)

    Zargham, Ardalan, E-mail: zargham@ifp.uni-bremen.d [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Schmidt, Thomas; Flege, Jan Ingo; Sauerbrey, Marc; Hildebrand, Radowan [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany); Roehe, Sarah; Baeumer, Marcus [Applied and Physical Chemistry, University of Bremen, Leobener Str. 2, 28359, Bremen (Germany); Falta, Jens [Institute of Solid State Physics, University of Bremen, Otto-Hahn-Allee 1, 28359 Bremen (Germany)

    2010-02-15

    We present a promising combination of methods to precisely determine the morphology of nanostructures, drawing on the example of monodisperse CoPt{sub 3} nanoparticle films deposited by spin coating and dip coating techniques on functionalized Au substrates. Ex-situ X-ray standing waves in total external reflection combined with X-ray reflectivity measurements were employed to determine element-specific atomic-density distributions in vertical direction.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are a form of radiation like light or radio waves. X-rays pass through most objects, including the body. Once it is carefully aimed at the part of the body being examined, an x-ray machine produces a small burst of radiation that passes through the body, recording ...

  5. Determination of mercury in seawater by total reflection x-ray fluorescence spectrometry after an electrochemical preconcentration method

    International Nuclear Information System (INIS)

    Ritschel, A.; Chinea Cano, E.; Wobrauschek, P.; Kuntner, C.; Durakbasa, M.N.

    2000-01-01

    A new combined method of electrodeposition of trace elements on metallic plates with subsequent total-reflection x-ray fluorescence spectrometry (TXRF) is proposed for the determination of trace metals in natural waters. The elements of interest are electroplated on highly polished niobium discs which are used as sample carriers for the TXRF measurement. The electrochemical preconcentration is performed in a flow cell under a controlled working electrode potential. The preconcentration step involves only very little manipulation which minimizes the risk of contamination of the sample. The method was investigated by analyzing inorganic mercury in sea water. A detection limit of 7 ngl -1 could be achieved for mercury in a 40 ml sea water sample. (author)

  6. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Zucchi, Orgheda Luiza Araujo Domingues; Nascimento Filho, Virgilio Franco do Centro de Energia Nuclear na Agricultura , Piracicaba, SP; Brazil)

    2005-01-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  7. Determination of copper, iron and zinc in spirituous beverages by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Capote, T.; Marcó, L. M.; Alvarado, J.; Greaves, E. D.

    1999-10-01

    The concentration of copper in traditional homemade alcoholic distillates produced in Venezuela (Cocuy de Penca) were determined by total reflection X-ray fluorescence (TXRF) using vanadium as internal standard. The results were compared to those obtained by flame atomic absorption spectrometry (FAAS). Three preparative methods of addition of vanadium were compared: classical internal standard addition, 'layer on layer' internal standard addition and in situ addition of internal standard. The TXRF procedures were accurate and the precision was comparable to that obtained by the FAAS technique. Copper levels were above the maximum allowed limits for similar beverages. Zinc and iron in commercial and homemade distilled beverages were also analyzed by TXRF with in situ addition of internal standard demonstrating the usefulness of this technique for trace metal determination in distillates.

  8. Fish samples as bioindicator of environmental quality: synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [Universidade Metodista de Piracicaba (UNIMEP), SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    In this study fish were used as bioindicators of environmental contamination. The species were collected in Piracicaba River, Sao Paulo state, Brazil and the toxic elements concentrations were determined in muscle tissue and viscus (liver, intestine and stomach) by Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF). Were determined the elements Ti, Cr, Mn, Fe, Ni, Cu, Zn and Ba. The results were compared with values established by Brazilian Legislation for general food. The elements concentrations evidenced potential risk to human health and environmental quality alteration of the studied area. The measurements were realized at the 'Laboratorio Nacional de Luz Sincrotron' (LNLS) located in Campinas, Sao Paulo State, Brazil. (author)

  9. Dose and induction to cancer risk evaluation associated to use of X ray body scanners by transmission at airports

    International Nuclear Information System (INIS)

    Correa, Samanda Cristine Arruda; Aquino, Josilto Oliveira de; Souza, Edmilson Monteiro de; Silva, Ademir Xavier da

    2011-01-01

    This paper uses the Monte Carlo MCNPX and the phantoms in male voxel and female voxel to evaluate the absorbed doses effective doses and the induction risk and the mortality due to cancer associated to exposures of individual submitted to X ray body scanners by transmission at various projections. The values of effective dose were calculated according to the recommended by the new ICRP 103 and the values of induction risks and mortality due to cancer were estimated through the document BEIR VII. (author)

  10. Diagnostic accuracy of full-body linear X-ray scanning in multiple trauma patients in comparison to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Joeres, A.P.W.; Heverhagen, J.T.; Bonel, H. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Exadaktylos, A. [Inselspital - University Hospital Bern (Switzerland). Dept. of Emergency Medicine; Klink, T. [Inselspital - University Hospital Bern (Switzerland). Univ. Inst. of Diagnostic, Interventional and Pediatric Radiology; Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-02-15

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2%, the specificity was 93.3%, the positive predictive value was 91%, and the negative predictive value was 57.5%. The overall sensitivity for vertebral fractures was 16.7%, and the specificity was 100%. The sensitivity was 48.7% and the specificity 98.2% for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS.40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.

  11. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    International Nuclear Information System (INIS)

    Hoefler, H.; Streli, C.; Wobrauschek, P.; Ovari, M.; Zaray, Gy.

    2006-01-01

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm 2 active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors

  12. Analysis of low Z elements in various environmental samples with total reflection X-ray fluorescence (TXRF) spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hoefler, H. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Streli, C. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria)]. E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, A-1020 Vienna (Austria); Ovari, M. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary); Zaray, Gy. [Eoetvoes University, Institute of Chemistry, H-1117, Budapest, Pazmany P. stny 1/a. (Hungary)

    2006-11-15

    Recently there is a growing interest in low Z elements such as carbon, oxygen up to sulphur and phosphorus in biological specimen. Total reflection X-ray fluorescence (TXRF) spectrometry is a suitable technique demanding only very small amounts of sample. On the other side, the detection of low Z elements is a critical point of this analytical technique. Besides other effects, self absorption may occur in the samples, because of the low energy of the fluorescence radiation. The calibration curves might be not linear any longer. To investigate this issue water samples and samples from human cerebrospinal fluid were used to examine absorption effects. The linearity of calibration curves in dependence of sample mass was investigated to verify the validity of the thin film approximation. The special requirements to the experimental setup for low Z energy dispersive fluorescence analysis were met by using the Atominstitute's TXRF vacuum chamber. This spectrometer is equipped with a Cr-anode X-ray tube, a multilayer monochromator and a SiLi detector with 30 mm{sup 2} active area and with an ultrathin entrance window. Other object on this study are biofilms, living on all subaqueous surfaces, consisting of bacteria, algae and fungi embedded in their extracellular polymeric substances (EPS). Many trace elements from the water are bound in the biofilm. Thus, the biofilm is a useful indicator for polluting elements. For biomonitoring purposes not only the polluting elements but also the formation and growth rate of the biofilm are important. Biofilms were directly grown on TXRF reflectors. Their major elements and C-masses correlated to the cultivation time were investigated. These measured masses were related to the area seen by the detector, which was experimentally determined. Homogeneity of the biofilms was checked by measuring various sample positions on the reflectors.

  13. Energy dispersive X-ray fluorescence analysis with multiple total reflection

    International Nuclear Information System (INIS)

    Freitag, K.

    1985-01-01

    The development of a total reflection XRF analyzer and the performance data of this instrument are described. The drastic reduction of the scattered radiation is the outstanding property of the method. Detection limits of elements and matrix effects are discussed. The competition with other methods of analysis has proven its advantages in a wide range. In addition to its multi-element features down to the picogram level, particularly its universal calibration function has turned out to be a great help in the analytical practice. (orig./RB)

  14. Evaluation of the impacts of the use of X-Ray body inspection technology in the Brazilian prison system

    International Nuclear Information System (INIS)

    Nante, T.A.; Lima, C.M. Araujo de; Lima, A.R.

    2017-01-01

    The crisis of the Brazilian Penitentiary System is visible with overcrowding, the appearance and growth of criminal factions, the lack of infrastructure of prisons, etc. This scenario led to the adoption of new technologies, such as the body inspection by X-rays, known as Body scanners. The technology is capable of detecting various illicit objects hidden under clothes or even in the pockets of individuals searched, following the recommendation of the National Council of Criminal and Penitentiary Policy, allowing a more effective search and the extinction of the intimate searches. The objective of this study is to evaluate the social impacts of the use of body inspection technology in prison units, including aspects of radiological protection related to operation and maintenance

  15. Expression and localization of Smad4 protein in mouse testis after whole-body X-ray irradiation

    International Nuclear Information System (INIS)

    Zhu Huaping; Zhang Yuanqiang; Zhao Jie; Zhao Yong; Ma Jing; Hou Wugang; Qi Yuhong

    2005-01-01

    The work is to determine whether and where Transforming growth factor-betas downstream Signaling molecule Smad4 is expressed in the testes after whole-body X-ray irradiation and shed light on the mechanisms of Transforming growth factor-betas/Smad signal pathway mediates cell fate decisions following X-ray exposure. Five groups of adult BALB/c mice, with ten mice in each group, received whole-body of X-ray at dose levels of 0.1 Gy, 0.5 Gy, 1.0 Gy, 1.5 Gy and 2.0 Gy. They were sacrificed at 16 hour, 1 week, 2 weeks, 3 weeks and 4 weeks after the irradiation. Cellular localization and expression changes were examined by immunohistochemical ABC method. Quantitative analysis of the immunostaining was made by an image analysis system. In the seminiferous tubules, the expression of Smad4 was modulated by irradiation. The immunostaining showed that 16 hour post-irradiation, there was a significant decline in the Leydig cell, and it was dose and time depended. In addition, the immunolocalization showed that Smad4 was not exclusively localized in the cytoplasm of Leydig cells, but also localized in various Stages of spermatogenesis after the exposure, especially in premeiotic spermatogonia and primary spermatocytes. There was just a little expression in the 2.0 Gy group 16 h after the irradiation and the 1.0 Gy and 1.5 Gy groups at 2 weeks after the irradiation. Therefore in the 0.1 Gy to 2.0 Gy groups at 3 weeks after the irradiation, the immunostaining positive cells were significantly increased in spermatogonia and primary spermatocytes. There was no significant change in sertoli cells with different doses and different times after the exposure. The different expression patterns and change by dose and time of Smad4, suggest that TGF-β/Smad signal pathway may affect aspect after X-ray impairment and Smad4 may play an important role during these periods. (authors)

  16. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  17. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  18. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  19. Distribution of elements in rat peripheral axons and nerve cell bodies determined by x-ray microprobe analysis

    Energy Technology Data Exchange (ETDEWEB)

    LoPachin, R.M. Jr.; Lowery, J.; Eichberg, J.; Kirkpatrick, J.B.; Cartwright, J. Jr.; Saubermann, A.J.

    1988-09-01

    X-ray microprobe analysis was used to determine concentrations (millimoles of element per kilogram dry weight) of Na, P, Cl, K, and Ca in cellular compartments of frozen, unfixed sections of rat sciatic and tibial nerves and dorsal root ganglion (DRG). Five compartments were examined in peripheral nerve (axoplasm, mitochondria, myelin, extraaxonal space, and Schwann cell cytoplasm), and four were analyzed in DRG nerve cell bodies (cytoplasm, mitochondria, nucleus, and nucleolus). Each morphological compartment exhibited characteristic concentrations of elements. The extraaxonal space contained high concentrations of Na, Cl, and Ca, whereas intraaxonal compartments exhibited lower concentrations of these elements but relatively high K contents. Nerve axoplasm and axonal mitochondria had similar elemental profiles, and both compartments displayed proximodistal gradients of decreasing levels of K, Cl, and, to some extent, Na. Myelin had a selectively high P concentration with low levels of other elements. The elemental concentrations of Schwann cell cytoplasm and DRG were similar, but both were different from that of axoplasm, in that K and Cl were markedly lower whereas P was higher. DRG cell nuclei contained substantially higher K levels than cytoplasm. The subcellular distribution of elements was clearly shown by color-coded images generated by computer-directed digital x-ray imaging. The results of this study demonstrate characteristic elemental distributions for each anatomical compartment, which doubtless reflect nerve cell structure and function.

  20. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon.

  1. Trajectory method in the theory of Laue diffraction of X rays in crystals: II. Effect of total reflection at bending deformation

    International Nuclear Information System (INIS)

    Kohn, V. G.

    2008-01-01

    The effect of total reflection (switching) of a spherical X-ray wave in the case of Laue diffraction in a crystal with bending deformation is analyzed by the trajectory method. Qualitative analytical description and computation of the spatial structure of the reflected beam for large and small distances between the spherical-wave source and the crystal are performed. The mechanism of much more efficient reflection of an X-ray beam by a deformed crystal in comparison with a perfect crystal is clearly demonstrated. It is also shown that the trajectory method is very convenient for description of the total reflection phenomenon

  2. Total reflection X-ray fluorescence as a convenient tool for determination of trace elements in microscale gasoline and diesel

    Science.gov (United States)

    Zhang, Airui; Jin, Axiang; Wang, Hai; Wang, Xiaokang; Zha, Pengfei; Wang, Meiling; Song, Xiaoping; Gao, Sitian

    2018-03-01

    Quantitative determination of trace elements like S, Fe, Cu, Mn and Pb in gasoline and S in diesel is of great importance due to the growing concerns over air pollution, human health and engine failure caused by utilization of gasoline and diesel with these harmful elements. A method of total reflection X-ray fluorescence (TXRF) was developed to measure these harmful trace elements in gasoline and diesel. A variety of factors to affect measurement results, including TXRF parameters, microwave-assisted digestion conditions and internal standard element and its addition, were examined to optimize these experimental procedures. The hydrophobic treatment of the surface of quartz reflectors to support the analyte with neutral silicone solutions could prepare thin films of gasoline and diesel digestion solutions for subsequent TXRF analysis. The proposed method shows good potential and reliability to determine the content of harmful trace elements in gasoline and diesel with high sensitivity and accuracy without drawing different standard calibration curves, and can be easily employed to screen gasoline and diesel in routine quality control and assurance.

  3. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    Energy Technology Data Exchange (ETDEWEB)

    Kulesh, N.A., E-mail: nikita.kulesh@urfu.ru [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Novoselova, I.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Immanuel Kant Baltic Federal University, 236041 Kaliningrad (Russian Federation); Safronov, A.P. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Beketov, I.V.; Samatov, O.M. [Institute of Electrophysics UD RAS, Amundsen 106, 620016 Ekaterinburg (Russian Federation); Kurlyandskaya, G.V. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); University of the Basque Country UPV-EHU, 48940 Leioa (Spain); Morozova, M. [Ural Federal University, Mira 19, 620002 Ekaterinburg (Russian Federation); Denisova, T.P. [Irkutsk State University, Karl Marks 1, 664003 Irkutsk (Russian Federation)

    2016-10-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  4. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Cristina, E-mail: vazquez@cnea.gov.a [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Custo, Graciela, E-mail: custo@cnea.gov.a [Comision Nacional de Energia Atomica, Gerencia Quimica, Av. Gral Paz 1499, B1650KNA, San Martin (Argentina); Barrio, Nestor, E-mail: nbarrio@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Burucua, Jose, E-mail: gburucua@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina); Boeykens, Susana [Universidad de Buenos Aires, Facultad de Ingenieria, Paseo Colon 850. C1063ACU, Buenos Aires (Argentina); Marte, Fernando, E-mail: fmarte@unsam.edu.a [CEIRCAB-TAREA, Universidad Nacional de San Martin (UNSAM), Escuela de Humanidades, Campus Miguelete, 25 de Mayo y Francia, B1650KNA, San Martin (Argentina)

    2010-09-15

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  5. Total reflection X-ray spectroscopy as a rapid analytical method for uranium determination in drainage water

    International Nuclear Information System (INIS)

    Matsuyama, Tsugufumi; Sakai, Yasuhiro; Izumoto, Yukie; Imaseki, Hitoshi; Hamano, Tsuyoshi; Yoshii, Hiroshi

    2017-01-01

    Uranium concentrations in drainage water are typically determined by α-spectrometry. However, due to the low specific radioactivity of uranium, the evaporation of large volumes of drainage water, followed by several hours of measurements, is required. Thus, the development of a rapid and simple detection method for uranium in drainage water would enhance the operation efficiency of radiation control workers. We herein propose a novel methodology based on total reflection X-ray fluorescence (TXRF) for the measurement of uranium in contaminated water. TXRF is a particularly desirable method for the rapid and simple evaluation of uranium in contaminated water, as chemical pretreatment of the sample solution is not necessary, measurement times are typically several seconds, and the required sample volume is low. We herein employed sample solutions containing several different concentrations of uranyl acetate with yttrium as an internal standard. The solutions were placed onto sample holders, and were dried prior to TXRF measurements. The relative intensity, otherwise defined as the net intensity ratio of the Lα peak of uranium to the Kα peak of yttrium, was directly proportional to the uranium concentration. Using this method, a TXRF detection limit for uranium in contaminated water of 0.30 μg/g was achieved. (author)

  6. Moments of the Bethe surface and total inelastic x-ray scattering cross sections for H2

    International Nuclear Information System (INIS)

    Sharma, B.S.; Thakkar, A.J.

    1987-01-01

    Moments, S(j,K), of the generalized oscillator strength distribution are global properties of the Bethe surface. Apart from S(-1,K) which is related to the Waller-Hartree incoherent scattering factor, little is known about these moments for nonzero K. This paper describes high-accuracy calculations of S(1,K) and S(2,K) for molecular hydrogen. Comparison with experiment is made, and the utility of simple asymptotic approximations is confirmed. The moments are used to calculate differential cross sections for the inelastic scattering of x rays using the constant-momentum-transfer and constant-angle theories of Bonham. These cross sections differ from the Waller-Hartree cross sections at large angles thus demonstrating the importance of making corrections to the Waller-Hartree theory if the incoherent scattering factor S(K) is to be extracted from experimental inelastic cross sections. Total cross sections for scattering of 6- and 7-keV photons from H 2 are compared with synchrotron radiation scattering experiments. The calculations suggest that the Bonham constant-angle cross sections agree best with experiment. However, further experimental and theoretical work is needed to obtain firm conclusions about the limitations of Waller-Hartree theory

  7. Trace metal determinations by total-reflection x-ray fluorescence analysis in the open Atlantic Ocean

    International Nuclear Information System (INIS)

    Schmidt, D.; Gerwinski, W.; Radke, I.

    1993-01-01

    The Intergovernmental Oceanographic Commission (IOC), as a major component of its programme ''Global Investigation of Pollution in the Marine Environment'' (GIPME), maintains a long-standing project on ''Open Ocean Baseline Studies of Trace Contaminants''. Initially, the Atlantic Ocean and trace metals were selected. Four deep-water stations in the Cape Basin, Angola Basin, Cape Verde Abyssal Plain and Seine Abyssal Plain were regularly sampled for at least 36 depths. Additional samples were taken between stations. Samples were distributed to participants and a similar number of additional laboratories. As a central part of our own contribution to the project, we determined the trace heavy metals manganese, nickel, copper, zinc and lead and the lighter selenium by total-reflection X-ray fluorescence analysis. For the TXRF, the pre-enrichment of the trace metals and the separation from the salt matrix were performed by complexation with sodium dibenzyldithiocarbamate and reverse-phase chromatography. Generally, very low levels of trace elements were found in filtered and unfiltered water samples from these remote areas of the open Atlantic Ocean. Typical examples of the distributions of trace metal concentrations on depth profiles from the four deep-water stations as well as intercomparisons between the stations are presented. (author)

  8. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  9. Elemental concentration analysis in the brain of young and old Wistar rats by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Serpa, Renata F.B.; Jesus, Edgar F.O. de; Lopes, Ricardo T.; Anjos, Marcelino J. dos; Carmo, Maria G.T. do; Rocha, Monica S.; Moreira, Silvana; Martinez, Ana M.B.

    2007-01-01

    It is well known that aging is associated with neurobehavioral deficits. The aging process of human brain is characterized by progressive neuronal loss. Furthermore, certain brain areas are more vulnerable to neuronal degeneration than others, reflecting an altered resistance to stress of the tissue itself and/or the lack of adequate immunological defense mechanisms in these regions. About the elemental levels in the brain, it is known that the excess ou deficiency of some elements are toxic for human healthy, being also related to several neurodegenerative diseases. In this way, the main goal of this work was to determine the elemental concentration in the hippocampus of young and old male (n = 10) and female (n = 10) Wistar rats by total reflection X-ray fluorescence spectrometry with synchrotron radiation (SR-TXRF). These measurements were carried out at XRF beam line at Light Synchrotron Brazilian Laboratory, Campinas, Brazil. About the results, we could observe that Al, Fe, Cu, Zn and Br levels were higher in the hippocampus of the old female rats than the young ones. On the other hand, only Cu levels were higher in the hippocampus of the old male rats than the young ones. Therefore, the aging of the hippocampus of the female rats can be characterized by an accumulate for Al, Fe, Cu, Zn and Br. The excess in these elements levels are also associated with several neurodegenerative disorders, such as Alzheimer' disease, Parkinson's disease and Huntington's disease. (author)

  10. Real-time fusion of coronary CT angiography with X-ray fluoroscopy during chronic total occlusion PCI

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshhajra, Brian B.; Takx, Richard A.P. [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Department of Radiology and Division of Cardiology, Boston, MA (United States); Stone, Luke L.; Yeh, Robert W.; Jaffer, Farouc A. [Harvard Medical School, Cardiac Cathetrization Laboratory, Cardiology Division, Massachusetts General Hospital, Boston, MA (United States); Girard, Erin E. [Siemens Healthcare, Princeton, NJ (United States); Brilakis, Emmanouil S. [Cardiology Division, Dallas VA Medical Center and UT Southwestern Medical Center, Dallas, TX (United States); Lombardi, William L. [University of Washington, Cardiology Division, Seattle, WA (United States)

    2017-06-15

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with X-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. (orig.)

  11. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    Barros, Haydn; Marco Parra, Lue-Meru; Bennun, Leonardo; Greaves, Eduardo D.

    2010-01-01

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL -1 . The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  12. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Liu, Yan; Ma, Jianhua; Fan, Yi; Liang, Zhengrong

    2012-12-07

    Previous studies have shown that by minimizing the total variation (TV) of the to-be-estimated image with some data and other constraints, piecewise-smooth x-ray computed tomography (CT) can be reconstructed from sparse-view projection data without introducing notable artifacts. However, due to the piecewise constant assumption for the image, a conventional TV minimization algorithm often suffers from over-smoothness on the edges of the resulting image. To mitigate this drawback, we present an adaptive-weighted TV (AwTV) minimization algorithm in this paper. The presented AwTV model is derived by considering the anisotropic edge property among neighboring image voxels, where the associated weights are expressed as an exponential function and can be adaptively adjusted by the local image-intensity gradient for the purpose of preserving the edge details. Inspired by the previously reported TV-POCS (projection onto convex sets) implementation, a similar AwTV-POCS implementation was developed to minimize the AwTV subject to data and other constraints for the purpose of sparse-view low-dose CT image reconstruction. To evaluate the presented AwTV-POCS algorithm, both qualitative and quantitative studies were performed by computer simulations and phantom experiments. The results show that the presented AwTV-POCS algorithm can yield images with several notable gains, in terms of noise-resolution tradeoff plots and full-width at half-maximum values, as compared to the corresponding conventional TV-POCS algorithm.

  13. Inorganic pigment study of the San Pedro Gonzalez Telmo Sibyls using total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Custo, Graciela; Barrio, Nestor; Burucua, Jose; Boeykens, Susana; Marte, Fernando

    2010-01-01

    This article describes the study carried out on a series of oil paintings on canvas from the eighteenth century that were restored at Centro de Produccion e Investigacion en Restauracion y Conservacion Artistica y Bibliografica - Tarea (CEIRCAB-Tarea), Buenos Aires, Argentina: the San Pedro Gonzalez Telmo Sibyls. Experimental study was undertaken to identify inorganic pigments and the technique used in their confection; and, in this way, try to add information about their local origin. Therefore special emphasis was put to infer technologies used in the manufacturing of these paintings. Elemental analysis was performed by total reflection X-ray fluorescence spectrometry (TXRF) and complemented by optical and polarized light microscopy. Microsampling was carefully done over areas of the paintings which were damaged and where a small additional loss will not be noticed. This investigation has shown that a variety of pigments were used, namely earth pigments (red and yellow ochres), white lead, vermilion, etc., and they were used either pure or in mixtures. This characterization helped conservators in their decisions regarding a better understanding of the deterioration processes. In addition, this research about the material composition allowed the art historians and restorers the possibility to obtain information about where, when or by whom The San Pedro Gonzalez Telmo Sibyls may have been painted.

  14. Total reflection X-ray fluorescence applied to the chemical elements analysis of the mate tea infusion (Ilex-paraguariensis)

    International Nuclear Information System (INIS)

    Lopes, Fabio; Appoloni, Carlos R.; Cunha, Richard M. da Silva e; Nascimento Filho, Virgilio Franco do

    2002-01-01

    The purpose was to evaluate simultaneously the chemical element concentrations from K to Sr (19≤Z≤38) range in six samples of mate tea (Ilex paraguariensis) infusion, commercially available in Paraguay and South of Brazil. The chemical analysis of this beverage has a great nutritional importance for the native people of these areas, due to their large daily consumption. For the determination of these elements the dry-ashing and total reflection X-rays fluorescence (TXRF) were used. The methodology showed limits of detection among 81 ng.mL-1 for K to 10 ng.mL -1 for Zn. Six infusion samples were prepared in triplicate, and the concentration was 3,8 to 10,2 μg.mL -1 for K, Ca and Mn, 0,21 to 1,07 μg. mL -1 for Fe and Zn and 0.03 to 0,17 μg.mL -1 for Ni, Cu, Br, Rb and Sr. The Mn and Ni concentrations are above the maximum permissible values for drinking water established by World Health Organization and Brazilian legislation (these organisms do not regulate the maximum permissible values for chemical elements in mate tea infusion). (author)

  15. Element determination in natural biofilms of mine drainage water by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mages, Margarete; Tuempling, Wolf von Jr.; Veen, Andrea van der; Baborowski, Martina

    2006-01-01

    Human impacts like mining activities lead to higher element concentration in surface waters. For different pollution levels, the consequences for aquatic organisms are not yet investigated in detail. Therefore, the aim of this investigation is to determine the influence of mining affected surface waters on biofilms. Elements like heavy metals can be absorbed on cell walls and on polymeric substances or enter the cytoplasm of the cells. Thus, they are important for the optimization of industrial biotechnological processes and the environmental biotechnology. Beyond this, biofilms can also play an important role in wastewater treatment processes and serve as bioindicators in the aquatic environment. The presented total reflection X-ray fluorescence spectroscopic investigation was performed to compare the element accumulation behavior of biofilms grown on natural or on artificial materials of drainage water affected by former copper mining activities. A high salt and heavy metal pollution is characteristic for the drainage water. For an assessment of these results, samples from stream Schlenze upstream the confluence with the drainage water, a small tributary of the Saale River in central Germany, were analyzed, too

  16. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G

    2018-06-01

    Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Total reflection x-ray fluorescence spectroscopy as a tool for evaluation of iron concentration in ferrofluids and yeast samples

    International Nuclear Information System (INIS)

    Kulesh, N.A.; Novoselova, I.P.; Safronov, A.P.; Beketov, I.V.; Samatov, O.M.; Kurlyandskaya, G.V.; Morozova, M.; Denisova, T.P.

    2016-01-01

    In this study, total reflection x-ray fluorescent (TXRF) spectrometry was applied for the evaluation of iron concentration in ferrofluids and biological samples containing iron oxide magnetic nanoparticles obtained by the laser target evaporation technique. Suspensions of maghemite nanoparticles of different concentrations were used to estimate the limitation of the method for the evaluation of nanoparticle concentration in the range of 1–5000 ppm in absence of organic matrix. Samples of single-cell yeasts grown in the nutrient media containing maghemite nanoparticles were used to study the nanoparticle absorption mechanism. The obtained results were analyzed in terms of applicability of TXRF for quantitative analysis in a wide range of iron oxide nanoparticle concentrations for biological samples and ferrofluids with a simple established protocol of specimen preparation. - Highlights: • Ferrofluids and yeasts samples were analysed by TXRF spectroscopy. • Simple protocol for iron quantification by means of TXRF was proposed. • Results were combined with magnetic, structural, and morphological characterization. • Preliminary conclusion on nanoparticles uptake mechanism was made.

  18. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    Science.gov (United States)

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different parts of the body absorb the x-rays in varying degrees. Dense ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to produce pictures of any bone in the body. It is commonly used to diagnose fractured bones ... x-rays involves exposing a part of the body to a small dose of ionizing radiation to ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... carefully aimed at the part of the body being examined, an x-ray machine produces a small ... the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning ...

  2. Cobalt coordination and clustering in alpha-Co(OH)(2) revealed by synchrotron X-ray total scattering.

    Science.gov (United States)

    Neilson, James R; Kurzman, Joshua A; Seshadri, Ram; Morse, Daniel E

    2010-09-03

    Structures of layered metal hydroxides are not well described by traditional crystallography. Total scattering from a synthesis-controlled subset of these materials, as described here, reveals that different cobalt coordination polyhedra cluster within each layer on short length scales, offering new insights and approaches for understanding the properties of these and related layered materials. Structures related to that of brucite [Mg(OH)(2)] are ubiquitous in the mineral world and offer a variety of useful functions ranging from catalysis and ion-exchange to sequestration and energy transduction, including applications in batteries. However, it has been difficult to resolve the atomic structure of these layered compounds because interlayer disorder disrupts the long-range periodicity necessary for diffraction-based structure determination. For this reason, traditional unit-cell-based descriptions have remained inaccurate. Here we apply, for the first time to such layered hydroxides, synchrotron X-ray total scattering methods-analyzing both the Bragg and diffuse components-to resolve the intralayer structure of three different alpha-cobalt hydroxides, revealing the nature and distribution of metal site coordination. The different compounds with incorporated chloride ions have been prepared with kinetic control of hydrolysis to yield different ratios of octahedrally and tetrahedrally coordinated cobalt ions within the layers, as confirmed by total scattering. Real-space analyses indicate local clustering of polyhedra within the layers, manifested in the weighted average of different ordered phases with fixed fractions of tetrahedrally coordinated cobalt sites. These results, hidden from an averaged unit-cell description, reveal new structural characteristics that are essential to understanding the origin of fundamental material properties such as color, anion exchange capacity, and magnetic behavior. Our results also provide further insights into the detailed

  3. Cobalt Coordination and Clustering in α-Co(OH)2 Revealed by Synchrotron X-ray Total Scattering

    International Nuclear Information System (INIS)

    Neilson, James R.; Kurzman, Joshua A.; Seshadri, Ram; Morse, Daniel E.

    2010-01-01

    Structures of layered metal hydroxides are not well described by traditional crystallography. Total scattering from a synthesis-controlled subset of these materials, as described here, reveals that different cobalt coordination polyhedra cluster within each layer on short length scales, offering new insights and approaches for understanding the properties of these and related layered materials. Structures related to that of brucite (Mg(OH) 2 ) are ubiquitous in the mineral world and offer a variety of useful functions ranging from catalysis and ion-exchange to sequestration and energy transduction, including applications in batteries. However, it has been difficult to resolve the atomic structure of these layered compounds because interlayer disorder disrupts the long-range periodicity necessary for diffraction-based structure determination. For this reason, traditional unit-cell-based descriptions have remained inaccurate. Here we apply, for the first time to such layered hydroxides, synchrotron X-ray total scattering methods - analyzing both the Bragg and diffuse components - to resolve the intralayer structure of three different α-cobalt hydroxides, revealing the nature and distribution of metal site coordination. The different compounds with incorporated chloride ions have been prepared with kinetic control of hydrolysis to yield different ratios of octahedrally and tetrahedrally coordinated cobalt ions within the layers, as confirmed by total scattering. Real-space analyses indicate local clustering of polyhedra within the layers, manifested in the weighted average of different ordered phases with fixed fractions of tetrahedrally coordinated cobalt sites. These results, hidden from an averaged unit-cell description, reveal new structural characteristics that are essential to understanding the origin of fundamental material properties such as color, anion exchange capacity, and magnetic behavior. Our results also provide further insights into the detailed

  4. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Canellas, Catarine G.L.; Leitao, Roberta G.; Lopes, Ricardo T.; Bellido, Alfredo Victor B.; Anjos, Marcelino J.

    2011-01-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly (α = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  5. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Leitao, Roberta G.; Lopes, Ricardo T., E-mail: catarine@lin.ufrj.b, E-mail: ricardo@lin.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear. Lab. de Instrumentaco Nuclear; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.b [State Institute of Hematology Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.b [Federal Fluminense University (UFF), Niteroi, RJ (Brazil). Chemistry Inst.; Anjos, Marcelino J., E-mail: marcelin@lin.ufrj.b [State University of Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.

    2011-07-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly ({alpha} = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  6. Evaluation of Fe and Zn/Cu ratio in serum of patients with sickle cell anemia by total reflection X-ray fluorescence using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Canellas, Catarine G.L.; Leitao, Roberta G; Lopes, Ricardo T., E-mail: catarine@lin.ufrj.b, E-mail: ricardo@lin.ufrj.b [Universidade Federal do Rio de Janeiro (PEN/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Engenharia Nuclear. Lab. de Instrumentaco Nuclear; Carvalho, Silvia M.F., E-mail: silvia@hemorio.rj.gov.b [State Institute of Hematology Arthur de Siqueira Cavalcanti (HEMORIO), Rio de Janeiro, RJ (Brazil); Bellido, Alfredo Victor B., E-mail: alfredo@ien.gov.b [Federal Fluminense University (UFF), Niteroi, RJ (Brazil). Chemistry Inst.; Anjos, Marcelino J., E-mail: marcelin@lin.ufrj.b [State University of Rio de Janeiro (UERJ), RJ (Brazil). Physics Inst.

    2011-07-01

    Sickle cell anemia (SCA) is a blood disorder that affects hemoglobin, the protein found in red blood cells that help carry oxygen throughout the body. In this work we have analyzed serum samples from patients with SCA by using total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). The SRTXRF measurements were performed at the X-ray fluorescence beamline at Brazilian National Synchrotron Light Laboratory (LNLS), in Campinas, Sao Paulo using a polychromatic beam. We have studied forty-three patients aged 18-50 years old, suffering from SCA and Sixty healthy volunteers aged 18-60 years old. It was possible to determine the concentrations of the following elements: P, S, Cl, K, Ca, Fe, Cu, Zn, Br and Rb. Student's t-test was applied in order to check whether the two populations (CG x SCA) had the same mean values. It was observed that elemental concentration of P, Cl, K, Fe, Cu, Zn and Br differed significantly ({alpha} = 0.05) between groups of healthy subjects and SCA. The concentrations of K, Fe and Cu in the serum samples of patients with SCA were larger 15%, 120 % and 20 %, respectively, when compared with the CG. On the other hand, the concentrations of P (-20 %), Cl (-6 %), Zn (-25 %) and Br (-22 %) were smaller than the values determined for the control group. The serum level Cu/Zn ratio was significantly higher (60%) in the serum samples of patients with SCA group than the CG. So, the Cu/Zn ratio can be used as an adjuvant index in enhancement for diagnosis of SCA. There are evidences of an association among Fe, Cu, Zn and Cu/Zn in the SCA pathogenesis process. (author)

  7. Comparison of Dual Energy X-ray Absorptiometry and Bioimpedance in Assessing Body Composition and Nutrition in Peritoneal Dialysis Patients

    DEFF Research Database (Denmark)

    Popovic, Velena; Zerahn, Bo; Heaf, James Goya

    2017-01-01

    OBJECTIVE: Peritoneal dialysis (PD) patients are characterized by protein malnutrition and muscle wasting. Reliable, easy, and cheap methods for evaluating nutrition are desirable. Three methods are commonly available: dual-energy X-ray absorptiometry (DXA), bioimpedance (BI), and subjective global...... assessment (SGA).The objective of the study was to compare the previously mentioned methods for assessment of body composition and nutritional status in PD patients. DESIGN: The study is cross-sectional and consisted of 72 PD patients from a single center PD ambulatorium. METHODS: Participants were measured...... in this population. OH might reduce DXA accuracy in PD patients. LTI and ICW may be useful measures to supplement SGA in assessing nutrition....

  8. Characteristic of immunological adaptive response induced by low level whole body irradiation with X-rays in mice

    International Nuclear Information System (INIS)

    Ju Guizhi; Song Chunhua; Qi Jin; Liu Shuzheng

    1995-01-01

    The range of preirradiated doses (D 1 ) and challenge doses (D 2 ) for the induction of immunological adaptive response and the optimum time intervals between D 1 and D 2 were investigated in Kunming mice. The results were as follows: 1. Single whole body preirradiation by X-rays with D 1 doses of 25∼100 mGy (12.5 mGy/min) could induce adaptive response of spontaneous incorporation of 3 H-TdR into thymocytes and the reaction of splenocytes to LPS. 2. With D 2 doses of 1.0 to 1.5 Gy, the adaptive response of spontaneous incorporation of 3 H-TdR into thymocytes and the reaction of splenocytes to ConA and LPS could be induced. 3. The optimum interval for the induction of immunological adaptive response between D 1 and D 2 could be 6∼12 h

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Bone X-ray (Radiography)? ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. ...

  11. Method and apparatus for examining a body by means of penetrating radiation such as x-rays

    International Nuclear Information System (INIS)

    Barnea, D.I.

    1984-01-01

    An image-reconstructive technique for examining a body by means of penetrating radiation, such as X-rays, is described. A pre-body collimator having a two-dimensional array of radiation-transmitting holes each bordered by radiation non-transmitting walls is disposed between the body and the source of radiation, and a plurality of exposures are made onto a radiation-sensitive surface, in which the radiation is projected through the collimator while the radiation source is at a plurality of different locations, such that during the successive exposures, the radiation from the source passes through different ray paths defined by the holes in the pre-body collimator. The radiation level received by each of the radiation-sensitive surface elements is detected, stored, and processed to reconstruct the two-dimensional radiation pattern but with enhanced resolution. Preferably a post-body collimator is also used to suppress scattering. Described are a four-exposure procedure and a nine-exposure procedure

  12. Body Fat Percentages by Dual-energy X-ray Absorptiometry Corresponding to Body Mass Index Cutoffs for Overweight and Obesity in Indian Children

    Directory of Open Access Journals (Sweden)

    Deepa Pandit

    2009-01-01

    Full Text Available Background Indians are suspected to have higher body fat percent at a given body mass index (BMI than their western counterparts. Objective To estimate percent body fat in apparently healthy Indian children and adolescents by dual-energy X-ray absorptiometry (DXA and explore linkages of BMI with body fat percent for better health risk assessment. Methods Age, weight, height of 316 boys and 250 girls (6–17 years were recorded. Body composition was measured by dual-energy X-ray absorptiometry (DXA. High adiposity was defined as body fat percent (BF% > McCarthy's 85th percentile of body fat reference data. Receiver operating characteristic analysis (ROC was carried out for CDC BMI Z score for it's ability to judge excess fatness. Results High BF% was seen in 38.5% boys and 54.0% girls (p < 0.05. Percentage of obese children as defined by the BMI cutoffs of International Obesity Task Force (IOTF (2.1% for boys and 6.9% for girls was lower than that using Indian (13.7% for boys and 20.9% for girls and CDC (14.1% for boys and 20.9% for girls cutoffs. The point closest to one on the ROC curves of CDC BMI Z-scores indicated high adiposity at BMI cutoff of 22 at the age of 17 yr in both the genders. Conclusions Higher body fat percentage is associated with lower BMI values in Indian children.

  13. A body is not a metaphor: Barbara Hammer's X-ray vision.

    Science.gov (United States)

    Osterweil, Ara

    2010-01-01

    This article examines three films by legendary experimental filmmaker Barbara Hammer that deal with the sick, aging, or dying body: Optic Nerve (1985), Sanctus (1990), and A Horse is Not a Metaphor (2008). By analyzing films that do not explicitly confront sexual identity, this article questions the continuing usefulness of the designation "lesbian filmmaker" when considering Hammer's diverse body of work. Tracing the "double consciousness" through which Hammer approaches the body and its construction in patriarchy-particularly in the discourse of medicine-this article argues that Hammer's is a thoroughly corporeal, but not exclusively lesbian, cinema.

  14. Effect of ¹⁸F-FDG administration on measurements of bone mineral density and body composition by dual-energy X-ray absorptiometry.

    Science.gov (United States)

    Kim, Dae-Weung; Kim, Woo Hyoung; Kim, Myoung Hyoun; Kim, Seong Su; Mo, Eun Hee; Lee, Chun Ho; Kim, Chang Guhn

    2013-01-01

    The purpose of this study was to determine whether antecedent administration of ¹⁸F-fluorodeoxyglucose (FDG) used in positron emission tomography (PET) scanning results in corruption of bone mineral density (BMD) and body composition measured by dual-energy X-ray absorptiometry (DXA) system. DXA measurements of BMD and body composition had been performed twice, before and after ¹⁸F-FDG PET scan in 30 patients. The comparison of pre-values and post-values of all BMD values showed a decrease after the injection. However, only the decrease of whole-body BMD (WB-BMD) was statistically significant (p < 0.05). Whole-body fat mass had increased and whole-body lean body mass had decreased after the injection of ¹⁸F-FDG, and these were statistically significant (p < 0.05). There is statistically significant correlation between the injected ¹⁸F-FDG dose and a decrease of WB-BMD (r = -0.405; p < 0.05). The findings of this study suggest that when both ¹⁸F-FDG PET and DXA measurements for whole-body composition are performed in close-time proximity, ¹⁸F-FDG PET scans should follow the DXA measurement. Otherwise, BMD measurements of total femur or lumbar spine could be followed by ¹⁸F-FDG PET in close-time proximity. Copyright © 2013 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  15. Dual-energy X-ray absorptiometry, skinfold thickness and waist circumference for assessing body composition in ambulant and non-ambulant wheelchair games players

    Directory of Open Access Journals (Sweden)

    Annika eWillems

    2015-11-01

    Full Text Available Field-based assessments provide a cost–effective and accessible alternative to dual-energy X-ray absorptiometry (DXA for practitioners determining body composition in athletic populations. It remains unclear how the range of physical impairments classifiable in wheelchair sports may affect the utility of field-based body composition techniques. The present study assessed body composition using DXA in 14 wheelchair games players who were either wheelchair dependent (non-walkers; n =7 or relied on a wheelchair for sports participation only (walkers; n =7. Anthropometric measurements were used to predict body fat percentage with existing regression equations established for able-bodied persons by Sloan & Weir, Durnin & Womersley, Lean et al, Gallagher et al and Pongchaiyakul et al. In addition, linear regression analysis was performed to calculate the association between body fat percentage and BMI, waist circumference, sum of 6 skinfold thicknesses and sum of 8 skinfold thicknesses. Results showed that non-walkers had significantly lower total lean tissue mass (46.2±=6.6 kg vs. 59.4±8.2 kg, P =.006 and total body mass (65.8 ±4.2 kg vs. 79.4 ±14.9 kg; P =0.05 than walkers. Body fat percentage calculated from most existing regression equations was significantly lower than that from DXA, by 2 to 9% in walkers and 8 to14% in non-walkers. Of the anthropometric measurements, the sum of 8 skinfold thicknesses had the lowest standard error of estimation in predicting body fat content. In conclusion, existing anthropometric equations developed in able-bodied populations substantially underestimated body fat content in wheelchair athletes, particularly non-walkers. Impairment specific equations may be needed in wheelchair athletes.

  16. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  17. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    International Nuclear Information System (INIS)

    Pessanha, Sofia; Carvalho, Maria Luisa; Becker, Maria; Bohlen, Alex von

    2010-01-01

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  18. Use of total-reflection x-ray fluorescence in search of a biomonitor for environmental pollution in Vietnam

    International Nuclear Information System (INIS)

    Boman, J.; Wagner, A.; Brauer, H.; Viet Binh, D.

    2000-01-01

    The concentration of trace elements in tissues of several animals collected in the Ha Nam province, about 25 km south of Hanoi, Vietnam, has been investigated using total-reflection x-ray fluorescence (TXRF). With this study we wanted to address whether any of the animals were possible candidates for being bio-monitors for the pollution situation in a selected area of Vietnam. We also aim to compare the measured trace element concentrations to those representative to other provinces in Vietnam as well as to other parts of the world. An extensive bio-diversity of animals exists in Vietnam, where many of them play an important economic role in the agricultural breeding and production. The accumulation process of trace elements is still not known for a large number of animals. The parts of the collected animals chosen for analysis were muscle tissue and liver. The specimens were dried under vacuum and kept frozen. Before the TXRF analysis, the solid and dried samples were digested in nitric acid. The analysis was made at the Department of Physics at Chalmers University of Technology and Goeteborg University, Sweden, where a TXRF spectrometer has been developed by the Environmental Physics group. The results show that there could be a large variation in the concentration of trace elements, not only between the different animals but also between tissue parts of the same animal. Obviously, when selecting an organism to be used as a bio-monitor, other factors than the mere concentration of trace elements must be considered. (author)

  19. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Science.gov (United States)

    Sánchez, Héctor Jorge; Valentinuzzi, María Cecilia; Grenón, Miram; Abraham, José

    2008-12-01

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  20. Vapor phase treatment–total reflection X-ray fluorescence for trace elemental analysis of silicon wafer surface

    International Nuclear Information System (INIS)

    Takahara, Hikari; Mori, Yoshihiro; Shibata, Harumi; Shimazaki, Ayako; Shabani, Mohammad B.; Yamagami, Motoyuki; Yabumoto, Norikuni; Nishihagi, Kazuo; Gohshi, Yohichi

    2013-01-01

    Vapor phase treatment (VPT) was under investigation by the International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) to improve the detection limit of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis of silicon wafers. Round robin test results have confirmed that TXRF intensity increased by VPT for intentional contamination with 5 × 10 9 and 5 × 10 10 atoms/cm 2 Fe and Ni. The magnification of intensity enhancement varied greatly (1.2–4.7 in VPT factor) among the participating laboratories, though reproducible results could be obtained for average of mapping measurement. SEM observation results showed that various features, sizes, and surface densities of particles formed on the wafer after VPT. The particle morphology seems to have some impact on the VPT efficiency. High resolution SEM observation revealed that a certain number of dots with SiO 2 , silicate and/or carbon gathered to form a particle and heavy metals, Ni and Fe in this study were segregated on it. The amount and shape of the residue should be important to control VPT factor. - Highlights: • This paper presents a summary of study results of VPT–TXRF using ISO/TC201/WG2. • Our goal is to analyze the trace metallic contamination on silicon wafer with concentrations below 1 × 10 10 atoms/cm 2 . • The efficiency and mechanism of VPT are discussed under several round robin tests and systematic studies

  1. Determination of As concentration in earthworm coelomic fluid extracts by total-reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Allegretta, Ignazio; Porfido, Carlo; Panzarino, Onofrio; Fontanella, Maria Chiara; Beone, Gian Maria; Spagnuolo, Matteo; Terzano, Roberto

    2017-04-01

    Earthworms are often used as sentinel organisms to study As bioavailability in polluted soils. Arsenic in earthworms is mainly sequestrated in the coelomic fluids whose As content can therefore be used to asses As bioavalability. In this work, a method for determining As concentration in coelomic fluid extracts using total-reflection X-ray fluorescence spectrometry (TXRF) is presented. For this purpose coelomic fluid extracts from earthworms living in three polluted soils and one non-polluted (control) soil have been collected and analysed. A very simple sample preparation was implemented, consisting of a dilution of the extracts with polyvinyl alcohol (PVA) using a 1:8 ratio and dropwise deposition of the sample on the reflector. A detection limit of 0.2 μg/l and quantification limit of 0.6 μg/l was obtained in the diluted samples, corresponding to 2 μg/l and 6 μg/l in the coelomic fluid extracts, respectively. This allowed to quantify As concentration in coelomic fluids extracted from earthworms living in soils polluted with As at concentrations higher than 20 mg/kg (considered as a pollution threshold for agricultural soils). The TXRF method has been validated by comparison with As concentrations in standards and by analysing the same samples by ICP-MS, after acid digestion of the sample. The low limit of detection, the proven reliability of the method and the little sample preparation make TXRF a suitable, cost-efficient and "green" technique for the analysis of As in earthworm coelomic fluid extracts for bioavailability studies.

  2. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    International Nuclear Information System (INIS)

    Sanchez, Hector Jorge; Valentinuzzi, Maria Cecilia; Grenon, Miram; Abraham, Jose

    2008-01-01

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis

  3. Determination of trace elements in freshwater rotifers and ciliates by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Woelfl, S.; Óvári, M.; Nimptsch, J.; Neu, T. R.; Mages, M.

    2016-02-01

    Element determination in plankton is important for the assessment of metal contamination of aquatic environments. Until recently, it has been difficult to determine elemental content in rotifers or ciliates derived from natural plankton samples because of the difficulty in handling and separation of these fragile organisms. The aim of this study was to evaluate methods for separation of rotifers and large ciliates from natural plankton samples (μg range dry weight) and subsequent analysis of their elemental content using total-reflection X-ray fluorescence spectrometry (TXRF). Plankton samples were collected from different aquatic environments (three lakes, one river) in Chile, Argentina and Hungary. From one to eighty specimens of five rotifer species (Brachionus calyciflorus, Brachionus falcatus, Asplanchna sieboldii, Asplanchna sp., Philodina sp.) and four to twelve specimens of one large ciliate (Stentor amethystinus) were prepared according to the dry method originally developed for microcrustaceans, and analysed by TRXF following in situ microdigestion. Our results demonstrated that it possible to process these small and fragile organisms (individual dry mass: 0.17-9.39 μg ind- 1) via careful washing and preparation procedures. We found species-dependent differences of the element mass fractions for some of the elements studied (Cr, Mn, Fe, Ni, Cu, Zn, As, Pb), especially for Cu, Fe and Mn. One large rotifer species (A. sieboldii) also showed a negative correlation between individual dry weight and the element content for Pb, Ni and Cr. We conclude that our application of the in situ microdigestion-TRXF method is suitable even for rotifers and ciliates, greatly expanding the possibilities for use of plankton in biomonitoring of metal contamination in aquatic environments.

  4. Total reflection X-ray fluorescence analysis of oral fluids of women affected by osteoporosis and osteopenia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Hector Jorge [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)], E-mail: jsan@famaf.unc.edu.ar; Valentinuzzi, Maria Cecilia [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Grenon, Miram [Facultad de Odontologia, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina); Abraham, Jose [Facultad de Matematica Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)

    2008-12-15

    Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility and an increased susceptibility to fractures; the early stage of decreased bone density is called osteopenia. More than 200 million people are affected and about 50% of post-menopausic women are expected to develop the disease. Osteoporosis, osteopenia and periodontal disease have in common several risk factors, being hyperthyroidism and smoking habits the most important ones. There is scarce information in the literature about the association between periodontal disease and osteoporosis and/or osteopenia. Some works suggest that osteoporotic women are susceptible to a higher loss of periodontal insertion, alveolar bones, and teeth. Thirty adult post-menopausic women were studied; some of them were healthy (control group) and the rest of them were undergoing some stage of osteoporosis or osteopenia. All the subjects were healthy, non-smokers, not having dental implants, and with communitarian periodontal index higher than 1(CPI > 1). Samples of saliva and gingival crevice fluid were extracted with calibrated micro-capillaries and deposited on Si reflectors. Known amounts of Ga were added to the samples in order to act as internal standard for quantification by the total reflection x-ray fluorescence technique. Experimental concentrations of several elements (P, S, Cl, K, Ca, Cr, Fe, NI, Cu, and Zn) were determined. The concentration of some elements in saliva showed different behavior as compared to gingival crevice fluid. Some critical elements of bone composition, such as Ca and Zn, present very distinguishable behavior. Improvements in the statistics are required for a better assessment of a routine method and to establish some correlation with periodontal disease. TXRF seems to be a promising method to evaluate the evolution of osteoporosis.

  5. Application of CO2 Snow Jet Cleaning in Conjunction with Laboratory Based Total Reflection X-Ray Fluorescence

    Science.gov (United States)

    Schmeling, M.; Burnett, D. S.; Allton, J. H.; Rodriquez, M.; Tripa, C. E.; Veryovkin, I. V.

    2013-01-01

    The Genesis mission was the first mission returning solar material to Earth since the Apollo program [1,2]. Unfortunately the return of the space craft on September 8, 2004 resulted in a crash landing, which shattered the samples into small fragments and exposed them to desert soil and other debris. Thus only small fragments of the original collectors are available, each having different degrees of surface contamination. Thorough surface cleaning is required to allow for subsequent analysis of solar wind material embedded within. An initial cleaning procedure was developed in coordination with Johnson Space Center which focused on removing larger sized particulates and a thin film organic contamination acquired during collection in space [3]. However, many of the samples have additional residues and more rigorous and/or innovative cleaning steps might be necessary. These cleaning steps must affect only the surface to avoid leaching and re-distribution of solar wind material from the bulk of the collectors. To aid in development and identification of the most appropriate cleaning procedures each sample has to be thoroughly inspected before and after each cleaning step. Laboratory based total reflection X-ray fluorescence (TXRF) spectrometry lends itself to this task as it is a non-destructive and surface sensitive analytical method permitting analysis of elements from aluminum onward present at and near the surface of a flat substrate [4]. The suitability of TXRF has been demonstrated for several Genesis solar wind samples before and after various cleaning methods including acid treatment, gas cluster ion beam, and CO2 snow jet [5 - 7]. The latter one is non-invasive and did show some promise on one sample [5]. To investigate the feasibility of CO2 snow jet cleaning further, several flown Genesis samples were selected to be characterized before and after CO2 snow application with sample 61052 being discussed below.

  6. Determination of platinum group metal catalyst residues in active pharmaceutical ingredients by means of total reflection X-ray spectrometry

    International Nuclear Information System (INIS)

    Marguí, Eva; Queralt, Ignasi; Hidalgo, Manuela

    2013-01-01

    The control of metal catalyst residues (i.e., platinum group metals (PGMs)) in different stages of the manufacturing processes of the active pharmaceutical ingredients (APIs) and, especially, in the final product is crucial. For API specimens, there are strict guidelines to limit the levels of metal residues based on their individual levels of safety concern. For PGMs the concentration limit has been established at 10 mg/kg in the API. Therefore great effort is currently being devoted to the development of new and simple procedures to control metals in pharmaceuticals. In the present work, an analytical methodology based on benchtop total reflection X-ray fluorescence spectrometry (TXRF) has been developed for the rapid and simple determination of some PGM catalyst impurities (Rh, Pd, Ir and Pt) in different types of API samples. An evaluation of different sample treatments (dissolution and digestion of the solid pharmaceutical samples) has been carried out and the developed methodologies have been validated according to the analytical parameters to be considered and acceptance criteria for PGM determination according to the United States Pharmacopeia (USP). Limits of quantification obtained for PGM metals were in the range of 2–4 mg/kg which are satisfactory according to current legislation. From the obtained results it is shown that the developed TXRF method can be implemented in the pharmaceutical industries to increase productivity of the laboratory; offering an interesting and complementary analytical tool to other atomic spectroscopic methods. - Highlights: • A TXRF method for PGM catalyst residue determination in API samples is presented. • Analysis can be performed using 10 μL of the internal standardized dissolved API. • The method is rapid, simple and suitable according to the USP requirements

  7. Measurement of body composition in cats using computed tomography and dual energy X-ray absorptiometry

    DEFF Research Database (Denmark)

    Buelund, Lene E; Nielsen, Dorte H; McEvoy, Fintan

    2011-01-01

    compared CT and DEXA data from 73 healthy adult neutered domestic cats. Three approaches for measuring adipose tissue percentage from full-body CT scans were explored. By examining the frequency distribution of voxels by Hounsfield unit (HU) value, it is possible to calculate a fat index (Fat...

  8. The relation between dual energy X-ray absorptiometry measurements of body fat composition and plasma ghrelin in patients with end-stage renal disease

    International Nuclear Information System (INIS)

    Elsayed, Naglaa M.; Hamed, Soha T.; El-Khatib, Mohamed M.; El-Shehaby, Amal M.

    2009-01-01

    Objective was to clarify the role of ghrelin in malnutrition in uremia and its relationship to fat composition using dual x-ray absorptiometry (DXA). This is a cohort study including Group I: 60 patients with end stage renal disease (30 on hemodialysis [group IA] and 30 pre-dialysis [group IB]) and Group II: 20 controls. This study was carried out in Cairo University Hospital, Kasr Al-Aini, Cairo, Egypt in 2007. Body fat composition (total, differential and lean body mass) was assessed using DXA and plasma ghrelin was measured. Ghrelin was significantly higher in hemodialysis and pre-dialysis groups compared to the control group and higher in hemodialysis group compared to the pre-dialysis group. In hemodialysis, ghrelin was negatively correlated with weight, body mass index (BMI), and truncal fat mass, and positively correlated with serum creatinine, lean body mass. In control, plasma ghrelin showed negative correlation with weight, BMI, truncal fat mass and positive correlation with lean body mass. Ghrelin was markedly elevated in renal failure due to its decrease in excretion. Negative correlation between ghrelin and fat mass composition was detected in dialysis patients. Serial evaluation of body fat mass composition using DXA is recommended for assessment of nutritional status of those patients. (author)

  9. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Ostachowicz, B.; Lankosz, M.; Tomik, B.; Adamek, D.; Wobrauschek, P.; Streli, C.; Kregsamer, P.

    2006-01-01

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group

  10. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Ostachowicz, B. [Department of Radiometric Analyses, Faculty of Physic and Applied Computer Science, AGH, University of Science and Technology, Cracow (Poland); Lankosz, M. [Department of Radiometric Analyses, Faculty of Physic and Applied Computer Science, AGH, University of Science and Technology, Cracow (Poland); Tomik, B. [Institute of Neurology, Collegium Medicum, Jagiellonian University, Cracow (Poland); Adamek, D. [Institute of Neurology, Collegium Medicum, Jagiellonian University, Cracow (Poland); Wobrauschek, P. [Atominstitut, Vienna University of Technology, Vienna (Austria); Streli, C. [Atominstitut, Vienna University of Technology, Vienna (Austria)]. E-mail: streli@ati.ac.at; Kregsamer, P. [Atominstitut, Vienna University of Technology, Vienna (Austria)

    2006-11-15

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group.

  11. Determination of total As in onion plants growing in contaminated substrates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue-Meru Marco Parra

    2011-01-01

    The onion (Allium cepa L.) is one of the most important cultivars in the world and its production level occupies the second place in Venezuela. It becomes important to develop analytical procedures for arsenic determination and to study the effect of this element on the cultures, as well the absorption, transport and translocation processes. A TXRF method for As determination in onions was developed. Two treatments were applied to the onion plants, As contaminated and control. The contaminant was added to the plants to an amount of 100 μg, in a single time 3 weeks after the transplant of plantlets. The green leaves bulbs, and roots together with the stems were separated 45 days after transplant and analyzed by TXRF and HG-AAS for total Arsenic determination. A good agreement was found between these two techniques, demonstrating the accuracy of the TXRF procedure. It was found that the highest concentration corresponded to the root and stems (37 ± 31 μg g -1 ), followed by the bulbs (11 ± 7 μg g -1 ), being the smallest level found in the green leaves (4 ± 3 μg g -1 ). At low As contamination levels of 0.25 μg g -1 , a risk for translocation of the toxic element to the edible parts of the onion plants exists. At this level the normal development of the plant is not affected, being the only exception the root length, which is significantly higher in the contaminated treatment. (author)

  12. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    International Nuclear Information System (INIS)

    Hu, Zhengyi; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W; Welch, Ian

    2015-01-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice. (paper)

  13. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    Science.gov (United States)

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.

    2015-08-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  14. X-Ray

    Science.gov (United States)

    ... enema. What you can expect During the X-ray X-rays are performed at doctors' offices, dentists' offices, ... as those using a contrast medium. Your child's X-ray Restraints or other techniques may be used to ...

  15. Abdominal x-ray

    Science.gov (United States)

    Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... talk with you about chest radiography also known as chest x-rays. Chest x-rays are the ... treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray ...

  17. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  18. Personal experience with whole-body, low-dosage, digital X-ray scanning (LODOX-Statscan in trauma

    Directory of Open Access Journals (Sweden)

    Zimmermann Heinz

    2009-09-01

    Full Text Available Abstract Background Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. Methods We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. Results and Conclusion The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm. The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.

  19. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of any bone in the body, including the hand, wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg ( ... Image Gallery Radiological technologist preparing to take an arm x-ray on a ... Images related ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray uses a very small dose of ionizing radiation to produce pictures of any bone in the ... of the body to a small dose of ionizing radiation to produce pictures of the inside of the ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive ...

  4. Total body irradiation

    International Nuclear Information System (INIS)

    Novack, D.H.; Kiley, J.P.

    1987-01-01

    The multitude of papers and conferences in recent years on the use of very large megavoltage radiation fields indicates an increased interest in total body, hemibody, and total nodal radiotherapy for various clinical situations. These include high dose total body irradiation (TBI) to destroy the bone marrow and leukemic cells and provide immunosuppression prior to a bone marrow transplant, high dose total lymphoid irradiation (TLI) prior to bone marrow transplantation in severe aplastic anemia, low dose TBI in the treatment of lymphocytic leukemias or lymphomas, and hemibody irradiation (HBI) in the treatment of advanced multiple myeloma. Although accurate provision of a specific dose and the desired degree of dose homogeneity are two of the physicist's major considerations for all radiotherapy techniques, these tasks are even more demanding for large field radiotherapy. Because most large field radiotherapy is done at an extended distance for complex patient geometries, basic dosimetry data measured at the standard distance (isocenter) must be verified or supplemented. This paper discusses some of the special dosimetric problems of large field radiotherapy, with specific examples given of the dosimetry of the TBI program for bone marrow transplant at the authors' hospital

  5. Precision of dual energy X-ray absorptiometry for body composition measurements in cats

    International Nuclear Information System (INIS)

    Borges, N.C.; Vasconcellos, R.S.; Canola, J.C.; Carciofi, A.C.; Pereira, G.T.; Paula, F.J.A.

    2008-01-01

    A short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342 g) and three females (BW=3459 g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy xray absorptiometry method provided precision for body composition measurements in adult cats. (author)

  6. Study of food intake dynamics in rats following acute whole-body irradiation with X rays

    International Nuclear Information System (INIS)

    Smajda, B.; Ahlers, I.; Datelinka, I.

    1987-01-01

    The effects were studied of whole-body X-irradiation with sublethal (2.39 Gy) and medium lethal (5.74 Gy) doses on food intake by rats. The lower dose caused a temporary decrease in food intake, with a minimum of 63.3% of the control level on the 2nd day after irradiation. The decrease was statistically significant up to the 4th day after irradiation. No substantial changes were observed in the parameters of the circadian rhythm in food intake with the maximum on the 3rd day after irradiation, with only 8% of the initial value. The food intake was reduced until the 9th day after irradiation. The daily thythm of food intake was strongly disturbed during the first three days after irradiation, then restoring gradually and on the 9th day showing the original phasing and shape. The results obtained were in agreement with the assumed neural regulation mechanism of food intake and its circadian rhythm in the rat. (author). 5 figs., 12 refs

  7. Absorbed dose to the patient by computerized whole body X-ray tomography

    International Nuclear Information System (INIS)

    Krauss, O.; Schuhmacher, H.

    1977-01-01

    The absorbed dose to the patient was measured for several medical investigations by computerized whole body scanning. An Alderson-phantom mounted with LiF-TLD was irradiated with a Delta-Scan (Ohio-Nuclear, 120 kV, 30 mA). The integral dose to the brain during a full examination (6 scans, filtration 3 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 3.2 rd and at the exit 0.6 rd. The dose to the eyes is 0.7 rd and to the thyroid gland 0.03 rd. The integral dose to the trunk (5 scans in the region of liver and kidneys, filtration 6 mm Al) was measured to 5x10 -2 J. The maximum absorbed dose at the entrance was found to be 2.4 rd and at the exit 0.25 rd. The dose to the gonads is less than 2 and 4 mrd if the distance between the last scan and the gonads is more than 15 cm

  8. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Gursky, H.

    1974-01-01

    This text contains ten chapters and three appendices. Following an introduction, chapters two through five deal with observational techniques, mechanisms for the production of x rays in a cosmic setting, the x-ray sky and solar x-ray emission. Chapters six through ten include compact x-ray sources, supernova remnants, the interstellar medium, extragalactic x-ray sources and the cosmic x-ray background. Interactions of x rays with matter, units and conversion factors and a catalog of x-ray sources comprise the three appendices. (U.S.)

  9. Total reflection x-ray fluorescence (TXRF) - a tool to obtain information about different air masses and air pollution

    International Nuclear Information System (INIS)

    Schmeling, M.

    2000-01-01

    Aerosols are solid particles dissolved in the atmosphere and have strong influence in the earth climate. Their solid surfaces are the only atmospheric medium for condensation of water leading to cloud formation and ultimately to precipitation. Besides their role in cloud formation, the elemental composition of aerosols reveals useful information about air masses and their transport patterns as well as air pollution. The elemental composition can be considered like a fingerprint of an air mass telling the story about its origin and fate. The presence of Al, Ti and Fe for instance indicates a source located in a highly exposed soil or often desert region, whereas Ni, V and Pb can be traced back to anthropogenic activities like fuel combustion or industrial processes. Other important source regions are the oceans, which emit the main aerosol constituents Na, Cl, and S. The concentrations of these elements in the atmosphere are extremely low and long sampling times are necessary to gain reliable results with most of the common analysis techniques. In contrast to this total reflection x-ray fluorescence (TXRF), as a technique capable to cope with tiny sample amounts, offers the unique possibility to reduce collection times to a minimum of minutes to hours. Such short sampling times in turn render it possible to monitor different air masses either passing through a ground based station or -in the ideal case- flown into by a small research aircraft. Different aerosol samples were taken by aircraft during the second aerosol characterization experiment (ACE-2) with sampling times ranging from 15 minutes up to one hour. These filter samples were analyzed by TXRF for trace elements subsequently. Together with background information about back trajectories and size distribution covering the time of sampling the presence of different air masses could be detected. In another project, short-term samples in the Chicago/Lake Michigan area are collected to study the air mass

  10. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Amberger, Martin A.; Hoeltig, Michael; Broekaert, Jose A.C.

    2010-01-01

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL -1 . As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL -1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g -1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al 2 O 3 , powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a

  11. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  12. Body composition and bone mineral mass in normal and obese female population using dual X-ray absorptiometry

    International Nuclear Information System (INIS)

    Massardo, T.; Gonzalez, P.; Coll, C.; Rodriguez, J.L.; Solis, I.; Oviedo, S.

    2002-01-01

    It has been observed that a greater percentage of body fat is associated with augmented bone mineral mass. Objective: The goal of this work was to assess the relationship between bone mineral density (BMD in g/cm 2 ) and content (BMC in g) and soft tissue components, fat and lean mass (in g) in whole body of adult female population in Chile. Method: We studied 185 volunteers, asymptomatic, excluding those using estrogens, regular medication, tobacco (>10 cigarettes/day), excessive alcohol intake or with prior oophorectomy. They were separated in 111 pre and 74 post menopausal and according to body mass index (BMI) they were 37 women > 30 kg/m 2 and 148 2 . A Lunar Dual X-Ray absorptiometer was used to determine whole BMD and BMC. Results: Post menopausal women were older and smaller [p:0.0001], with higher body mass index [p:0.0007] and with lower BMD and BMC and higher fat mass than the pre menopausal group; In the whole group, women with BMI ≥ 30 (obese) were compared with normal weight observing no difference in BMD. The fat mass incremented significantly with age. Obese women > 50 years presented greater BMC than the non-obese. The percentage of fat corresponded to 48% in the obese group and to 39% in the non-obese [p<0.0001]. Conclusion: Fat mass somehow protect bone mineral loss in older normal population, probably associated to multifactorial causes including extra ovaric estrogen production. Postmenopausal women presented lower mineral content than premenopausal, as it was expected

  13. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua, G. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico)]. E-mail: gzo@nuclear.inin.mx; Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Barcelo-Quintal, I. [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Mexico, D.F. (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico, D.F. (Mexico)

    2006-11-15

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 {mu}g/L) > Mn (300 {mu}g/L) > Cu (66 {mu}g/L) > Cr (21 {mu}g/L) > Pb (15 {mu}g/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  14. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Zarazua, G.; Ávila-Pérez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martínez, T.

    2006-11-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits.

  15. Analysis of total and dissolved heavy metals in surface water of a Mexican polluted river by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zarazua, G.; Avila-Perez, P.; Tejeda, S.; Barcelo-Quintal, I.; Martinez, T.

    2006-01-01

    The present area of study is located in the Upper Course of the Lerma River (UCLR). The Lerma is one of the most important rivers of Mexico, where it drains highly populated and industrialized regions. The aim of the present study is to determine the heavy metal concentration of Cr, Mn, Fe, Cu and Pb in dissolved and total phases of the UCLR by means of Total Reflection X-ray Fluorescence Spectrometry (TXRF). The surface water samples were collected at 8 sites distributed following the stream flow direction of the river. Four sampling campaigns were carried out in each site in a 1-year period. A sample preparation method was applied in order to obtain the total and dissolved fraction and to destroy the organic matter. The total heavy metal average concentration decrease in the following order: Fe (2566 μg/L) > Mn (300 μg/L) > Cu (66 μg/L) > Cr (21 μg/L) > Pb (15 μg/L). In general, the heavy metal concentrations in water of the UCLR are below the maximum permissible limits

  16. Reference data for bone density and body composition measured with dual energy x ray absorptiometry in white children and young adults

    NARCIS (Netherlands)

    I.M. van der Sluis (Inge); M.A.J. de Ridder (Maria); A.M. Boot (Annemieke); E.P. Krenning (Eric); S.M.P.F. de Muinck Keizer-Schrama (Sabine)

    2002-01-01

    textabstractAIMS: To obtain normative data on bone mineral density and body composition measured with dual energy x ray absorptiometry (DXA) from early childhood to young adulthood. METHODS: Cross sectional results from 444 healthy white volunteers (4-20 years) in the Netherlands

  17. The Translucent Cadaver: An Evaluation of the Use of Full Body Digital X-Ray Images and Drawings in Surface Anatomy Education

    Science.gov (United States)

    Kotze, Sanet Henriet; Mole, Calvin Gerald; Greyling, Linda Magdalena

    2012-01-01

    It has been noted by staff at the Faculty of Health Sciences, Stellenbosch University that medical students neglect the study of surface anatomy during dissection. This study reports on the novel use of Lodox[R] Statscan[R] images in anatomical education, particularly the teaching of surface anatomy. Full body digital X-ray images (Lodox Statscan)…

  18. X-ray filter for chest X-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    A description is given of an X-ray filter comprised of a sheet of radiation absorbing material with an opening corresponding to the spine and central portion of the heart. The upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter. This filter will permit an acceptable density level of x-ray exposure for the lungs while allowing a higher level of x-ray exposure for the mediastinum areas of the body. (author)

  19. X-ray filter for chest x-rays

    International Nuclear Information System (INIS)

    Ferlic, D.J.

    1984-01-01

    Filter for use in medical x-ray apparatus to permit higher intensity x-ray exposure in the heart and mediastinum area while maintaining a normal level of x-ray exposure in other areas of the body, particlarly in the lung area. The filter comprises a sheet of radiation absorbing material having an opening therein, said opening corresponding to the spine and central portion of the heart. Accordingly, the upper portion of the filter exhibits a relatively narrow opening which becomes gradually wider toward the lower portion of the filter

  20. X-ray microtomography

    International Nuclear Information System (INIS)

    Dunsmuir, J.H.; Ferguson, S.R.; D'Amico, K.L.; Stokes, J.P.

    1991-01-01

    In this paper the authors describe the application of a new high-resolution X-ray tomographic microscope to the study of porous media. The microscope was designed to exploit the properties of a synchrotron X-ray source to perform three dimensional tomography on millimeter sized objects with micron resolution and has been used in materials science studies with both synchrotron and conventional and synchrotron sources will be compared. In this work the authors have applied the microscope to measure the three dimensional structure of fused bead packs and berea sandstones with micron resolution and have performed preliminary studies of flow in these media with the microscope operated in a digital subtraction radiography mode. Computer graphics techniques have been applied to the data to visually display the structure of the pore body system. Tomographic imaging after flow experiments should detect the structure of the oil-water interface in the pore network and this work is ongoing

  1. Preclinical validation of automated dual-energy X-ray absorptiometry and computed tomography-based body composition measurements

    International Nuclear Information System (INIS)

    DEVRIESE, Joke; Pottel, Hans; BEELS, Laurence; VAN DE WIELE, Christophe; MAES, Alex; GHEYSENS, Olivier

    2016-01-01

    The aim of this study was to determine and validate a set of Hounsfield unit (HU) ranges to segment computed tomography (CT) images into tissue types and to test the validity of dual-energy X-ray absorptiometry (DXA) tissue segmentation on pure, unmixed porcine tissues. This preclinical prospective study was approved by the local ethical committee. Different quantities of porcine bone tissue (BT), lean tissue (LT) and adipose tissue (AT) were scanned using DXA and CT. Tissue type segmentation in DXA was performed via the standard clinical protocol and in CT through different sets of HU ranges. Percent coefficients of variation (%CV) were used to assess precision while % differences of observed masses were tested against zero using the Wilcoxon signed-rank Test. Total mass DXA measurements differ little but significantly (P=0.016) from true mass, while total mass CT measurements based on literature values show non-significant (P=0.69) differences of 1.7% and 2.0%. BT mass estimates with DXA differed more from true mass (median -78.2 to -75.8%) than other tissue types (median -11.3 to -8.1%). Tissue mass estimates with CT and literature HU ranges showed small differences from true mass for every tissue type (median -10.4 to 8.8%). The most suited method for automated tissue segmentation is CT and can become a valuable tool in quantitative nuclear medicine.

  2. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    Science.gov (United States)

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.

  3. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    International Nuclear Information System (INIS)

    Lopez G, A. H.; Costa, P. R.; Tomal, A.

    2014-08-01

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  4. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  5. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A. H.; Costa, P. R. [University of Sao Paulo, Institute of Physics, Laboratory of Radiation Dosimetry and Medical Physics, Matao Street, alley R, 187, 66318 Sao Paulo (Brazil); Tomal, A., E-mail: ahlopezg@usp.br [Universidade Federal de Goias, Physics Institute, Campus Samambaia, 131 Goiania, Goias (Brazil)

    2014-08-15

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  6. Sex- and age-specific percentiles of body composition indices for Chinese adults using dual-energy X-ray absorptiometry.

    Science.gov (United States)

    Xiao, Zeyu; Guo, Bin; Gong, Jian; Tang, Yongjin; Shang, Jingjie; Cheng, Yong; Xu, Hao

    2017-10-01

    The aims of the study were to develop sex- and age-specific percentiles for lean mass index (LMI), appendicular LMI (aLMI), fat mass index (FMI), and body fat distribution indices in Chinese adults using dual-energy X-ray absorptiometry (DXA), and to compare those indices with those of other ethnicities using the US NHANES data. Whole-body and regional lean mass and fat mass (FM) were measured using DXA in 5688 healthy males (n = 1693) and females (n = 3995) aged 20-90 years. Body fat distribution indices were expressed as % fat trunk/% fat legs, trunk/appendicular FM ratio (FMR), and android/gynoid FMR. Percentile curves of LMI, aLMI, FMI, and body fat distribution indices were obtained by the Lambda-Mu-Sigma method. The aLMI and LMI were negatively associated with age, decreasing from the fifth decade for males, but were not associated with age in females. Females had more total FM than males, whereas males had greater central adiposity (% fat trunk/% fat legs ratio, trunk/appendicular FMR, and android/gynoid FMR) than females. Moreover, FMI and body fat distribution indices consistently increased with age in both sexes, especially in women. In comparison with white, black, and Mexican populations in the USA, Chinese adults had lower total FM, but had greater central adiposity (% fat trunk/% fat legs ratio and trunk/appendicular FMR). Additionally, older white and Mexican populations showed greater decreases for aLMI and LMI than their Chinese counterparts. We present the sex- and age-specific percentiles for aLMI, LMI, FMI, and body fat distribution indices by DXA in Chinese adults, which may refine the individual assessment of the nutritional status of Chinese adults.

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed x-ray exams and use a very small dose of ... of the inside of the chest. A chest x-ray is used to evaluate the lungs, heart and ...

  8. Predictive Validity of the Body Adiposity Index in Overweight and Obese Adults Using Dual-Energy X-ray Absorptiometry

    Science.gov (United States)

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; García-Hermoso, Antonio; Triana-Reina, Hector Reynaldo

    2016-01-01

    The body adiposity index (BAI) is a recent anthropometric measure proven to be valid in predicting body fat percentage (BF%) in some populations. However, the results have been inconsistent across populations. This study was designed to verify the validity of BAI in predicting BF% in a sample of overweight/obese adults, using dual-energy X-ray absorptiometry (DEXA) as the reference method. A cross-sectional study was conducted in 48 participants (54% women, mean age 41.0 ± 7.3 years old). DEXA was used as the “gold standard” to determine BF%. Pearson’s correlation coefficient was used to evaluate the association between BAI and BF%, as assessed by DEXA. A paired sample t-test was used to test differences in mean BF% obtained with BAI and DEXA methods. To evaluate the concordance between BF% as measured by DEXA and as estimated by BAI, we used Lin’s concordance correlation coefficient and Bland–Altman agreement analysis. The correlation between BF% obtained by DEXA and that estimated by BAI was r = 0.844, p < 0.001. Paired t-test showed a significant mean difference in BF% between methods (BAI = 33.3 ± 6.2 vs. DEXA 39.0 ± 6.1; p < 0.001). The bias of the BAI was −6.0 ± 3.0 BF% (95% CI = −12.0 to 1.0), indicating that the BAI method significantly underestimated the BF% compared to the reference method. Lin’s concordance correlation coefficient was considered stronger (ρc = 0.923, 95% CI = 0.862 to 0.957). In obese adults, BAI presented low agreement with BF% measured by DEXA; therefore, BAI is not recommended for BF% prediction in this overweight/obese sample studied. PMID:27916871

  9. X-ray sky

    International Nuclear Information System (INIS)

    Gruen, M.; Koubsky, P.

    1977-01-01

    The history is described of the discoveries of X-ray sources in the sky. The individual X-ray detectors are described in more detail, i.e., gas counters, scintillation detectors, semiconductor detectors, and the principles of X-ray spectrometry and of radiation collimation aimed at increased resolution are discussed. Currently, over 200 celestial X-ray sources are known. Some were identified as nebulae, in some pulsations were found or the source was identified as a binary star. X-ray bursts of novae were also observed. The X-ray radiation is briefly mentioned of spherical star clusters and of extragalactic X-ray sources. (Oy)

  10. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran.

    Science.gov (United States)

    Salamat, Mohammad Reza; Salamat, Amir Hossein; Abedi, Iraj; Janghorbani, Mohsen

    2013-01-01

    Objective. Although several studies have investigated the association between body mass index (BMI) and bone mineral density (BMD), the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft) and lumbar vertebrae (L2-L4) using a Dual-Energy X-ray Absorptiometry (DXA) scan and examination of body size. Participants were categorised in two BMI group: normal weight obese, BMI ≥ 25 kg/m(2). Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93) and for osteoporosis was 4.4 (1.51, 12.87) for men with BMI osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  11. Relationship between Weight, Body Mass Index, and Bone Mineral Density in Men Referred for Dual-Energy X-Ray Absorptiometry Scan in Isfahan, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Salamat

    2013-01-01

    Full Text Available Objective. Although several studies have investigated the association between body mass index (BMI and bone mineral density (BMD, the results are inconsistent. The aim of this study was to further investigate the relation between BMI, weight and BMD in an Iranian men population. Methods. A total of 230 men 50-79 years old were examined. All men underwent a standard BMD scans of hip (total hip, femoral neck, trochanter, and femoral shaft and lumbar vertebrae (L2-L4 using a Dual-Energy X-ray Absorptiometry (DXA scan and examination of body size. Participants were categorised in two BMI group: normal weight <25.0 kg/m2 and overweight and obese, BMI ≥ 25 kg/m2. Results. Compared to men with BMI ≥ 25, the age-adjusted odds ratio of osteopenia was 2.2 (95% CI 0.85, 5.93 and for osteoporosis was 4.4 (1.51, 12.87 for men with BMI < 25. It was noted that BMI and weight was associated with a high BMD, compatible with a diagnosis of osteoporosis. Conclusions. These data indicate that both BMI and weight are associated with BMD of hip and vertebrae and overweight and obesity decreased the risk for osteoporosis. The results of this study highlight the need for osteoporosis prevention strategies in elderly men as well as postmenopausal women.

  12. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Brienza, Sandra Maria B.; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario; Zucchi, Orgheda L.A.D.; Nascimento Filho, Virgilio F.

    2005-01-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  13. Monitoring environmental pollution of trace elements in tree-rings by synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Brienza, Sandra Maria B. [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil) Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Medeiros, Jean Gabriel S.; Tomazello Filho, Mario [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]. E-mail: jeangm@esalq.usp.br; mtomazel@esalq.usp.br; Zucchi, Orgheda L.A.D. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br

    2005-07-01

    This paper aims to study the environmental pollution in the tree development, as a manner to evaluate its use as bioindicator in urban and country sides. The sample collecting was carry out in Piracicaba city, Sao Paulo State, that presents high level of environmental contamination of the water, soil and air, due industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. It was selected the Caesalpinia peltophoroides ('Sibipiruna') specie because its very used in urban arborization. It was employed the analytical technique named total reflection X-ray fluorescence (TXRF) to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was done in the Brazilian Synchrotron Light Laboratory, using a white beam for excitation and a Si(Li) detector for characteristic X-ray detection. It was quantified the P, K, Ca, Ti, Fe, Sr, Ba e Pb elements. (author)

  14. X-ray Ordinance

    International Nuclear Information System (INIS)

    Kramer, R.; Zerlett, G.

    1983-01-01

    This commentary, presented as volume 2 of the Deutsches Strahlenschutzrecht (German legislation on radiation protection) deals with the legal provisions of the ordinance on the protection against harmful effects of X-radiation (X-ray Ordinance - RoeV), of March 1, 1973 (announced in BGBl.I, page 173), as amended by the ordinance on the protection against harmful effects of ionizing radiation, of October 13, 1976 (announced in BGBl. I, page 2905). Thus volume 2 completes the task started with volume 1, namely to present a comprehensive view and account of the body of laws governing radiation protection, a task which was thought useful as developments in the FRG led to regulations being split up into the X-ray Ordinance, and the Radiation Protection Ordinance. In order to present a well-balanced commentary on the X-ray Ordinance, it was necessary to discuss the provisions both from the legal and the medical point of view. This edition takes into account the Fourth Public Notice of the BMA (Fed. Min. of Labour and Social Affairs) concerning the implementation of the X-ray Ordinance of January 4, 1982, as well as court decisions and literature published in this field, until September 1982. In addition, the judgment of the Federal Constitutional Court, dated October 19, 1982, concerning the voidness of the law on government liability, and two decisions by the Federal High Court, dated November 23, 1982, concerning the right to have insight into medical reports - of great significance in practice - have been considered. This commentary therefore is up to date with current developments. (orig.) [de

  15. Two different preparation techniques for trace element determination of single Daphnia specimen using total reflection x-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Woelfl, S.; Mages, M.

    2000-01-01

    Bio accumulation gives first information about the bio-availability of elements in waters and becomes more and more important for the characterization of the water quality. The use of common analytical techniques like ICP-MS and AAS requires large quantities of biologic sample material. Single preparation for example of Daphnia, a common species for bio-test experiments, are hardly possible with these procedures. Therefore alternatively quantitative TXRF element determination of individually prepared Daphnia was developed. Two preparation techniques for single freshwater crustacean specimen from a eutrophic branch of the river Elbe in the 'Rothehorn Park', Magdeburg (Daphnia: dry weight: 10 - 50 μg individuum -1 ) had been tested: (1) Wet preparation: the single Daphnia specimen had been washed with 0.45 μm filtered lake water and put onto quartz sample carriers. After air drying, the body length were determined in order to calculate the dry weight according to previously established body lengths-dry weight relationships. (2) Dry preparation: after collection specimen were washed with 0.45 μm filtered lake water and frozen in liquid nitrogen. The individual lyophilisated dried Daphnia were weighted using an ultrafine micro-balance and put onto quartz sample carriers. After preparation, addition of some μl Gallium standard solution and air drying the individual Daphnia were digested at the quartz sample carriers with 10 μl HNO 3 on a hot plate and dried once more. Finally the element concentrations were determined using a EXTRA IIA total-reflection x-ray fluorescence spectrometer. As a result of these investigations we can conclude that both, the 'dry' and 'wet' preparation method can be used for the element determination in small single crustaceans using TXRF spectrometry. It seems that the 'dry' method yields more precise results, but the wet method is easier to handle in field when samples cannot be fixed with liquid nitrogen. (author)

  16. X-ray tube target

    International Nuclear Information System (INIS)

    Weber, R.G.

    1980-01-01

    A target with an improved heat emissive surface for use in a rotating anode type x-ray tube is described. The target consists of a body having a first surface portion made of x-ray emissive material and a second surface portion made of a heat emissive material comprising at least one of hafnium boride, hafnium oxide, hafnium nitride, hafnium silicide, and hafnium aluminide. (U.K.)

  17. X-ray radiotherapy

    International Nuclear Information System (INIS)

    Tronc, D.

    1995-01-01

    Full text: The most common form of radio therapy is X-ray therapy, where a beam of photons or their parent electrons break down hydrogen bonds within the body's cells and remove certain DNA information necessary for cell multiplication. This process can eradicate malignant cells leading to complete recovery, to the remission of some cancers, or at least to a degree of pain relief. The radiotherapy instrument is usually an electron linac, and the electrons are used either directly in 'electrotherapy' for some 10% of patients, or the electrons bombard a conversion target creating a broad beam of high energy photons or 'penetration X-rays'. The simplest machine consists of several accelerating sections at around 3 GHz, accelerating electrons to 6 MeV; a cooled tungsten target is used to produce a 4 Gray/min X-ray field which can be collimated into a rectangular shape at the patient position. This tiny linac is mounted inside a rotating isocentric gantry above the patient who must remain perfectly still. Several convergent beams can also be used to increase the delivered dose. More sophisticated accelerators operate at up to 18 MeV to increase penetration depths and decrease skin exposure. Alternatively, electrotherapy can be used with different energies for lower and variable penetration depths - approximately 0.5 cm per MeV. In this way surface tissue may be treated without affecting deeper and more critical anatomical regions. This type of linac, 1 to 2 metres long, is mounted parallel to the patient with a bending magnet to direct the beam to the radiotherapy system, which includes the target, thick movable collimator jaws, a beam field equalizer, dose rate and optical field simulation and energy controls. There are over 2000 acceleratorbased X-ray treatment units worldwide. Western countries have up to two units per million population, whereas in developing countries such as Bangladesh, the density is only one per 100 million. Several

  18. Producing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.; Jung, R.G.; Applebaum, D.C.; Fairand, B.P.; Gallagher, W.J.

    1977-01-01

    A method of producing x-rays by directing radiant energy from a laser onto a target is described. Conversion efficiency of at least about 3 percent is obtained by providing the radiant energy in a low-power precursor pulse of approximately uniform effective intensity focused onto the surface of the target for about 1 to 30 nanoseconds so as to generate an expanding unconfined coronal plasma having less than normal solid density throughout and comprising a low-density (underdense) region wherein the plasma frequency is less than the laser radiation frequency and a higher-density (overdense) region wherein the plasma frequency is greater than the laser radiation frequency and, about 1 to 30 nanoseconds after the precursor pulse strikes the target, a higher-power main pulse focused onto the plasma for about 10 -3 to 30 nanoseconds and having such power density and total energy that the radiant energy is absorbed in the underdense region and conducted into the overdense region to heat it and thus to produce x-rays therefrom with the plasma remaining substantially below normal solid density and thus facilitating the substantial emission of x-rays in the form of spectral lines arising from nonequilibrium ionization states

  19. Development of an ionization chamber based high sensitivity detector for the measurement of radiation dose from X-ray whole body scanners

    International Nuclear Information System (INIS)

    Singh, Sunil K.; Tripathi, S.M.; LijiShaiju; Sathian, V.; Kulkarni, M.S.

    2016-01-01

    Using walk through metal detectors and undergoing frisking for personals at airports, seaports, railway stations and other sensitive places no longer meets proper security requirements. Now a days use of plastic explosives, drug trafficking or illegal carriage of dangerous items concealed under cloths or body cavities has increased many folds which in many cases is not possible to detect by conventional methods. One of the systems which are capable to overcome the above mentioned difficulties is the use of X-ray based whole body scanners, either transmission type or backscatter type, depending upon the nature of requirement. While using these whole body scanners the person being scanned possesses a radiation risk whose safety aspects can be monitored by following international standards (recommending certain dose limits). In order to check the compliance of these dose limits, the dose per scan received by the person (from these whole body scanners) needs to be measured. A very high sensitive ionization chamber has been designed and fabricated for measuring these extremely low X- ray fields ( few μR) produced by a scanning X-ray beam over a large area. A methodology has been developed to measure exposure per scan using large volume ionization chambers. This value of exposure was used to calculate whole body dose as per the recommendations of ANSI standard for its compliance

  20. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  1. Analysis of elemental maps from glaze to body of ancient Chinese Jun and Ru porcelain by micro-X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Lin [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing Radiation Center, Beijing 100875 (China)], E-mail: chenglin@bnu.edu.cn; Li Rongwu [Department of Physics, Beijing Normal University, Beijing 100049 (China); Pan Qiuli [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing Radiation Center, Beijing 100875 (China); Li Guoxia; Zhao Weijuan [Institute of Physical Engineering, Zhengzhou University, Zhengzhou 450052 (China); Liu Zhiguo [Key Laboratory of Beam Technology and Material Modification of Ministry of Education, College of Nuclear Science and Technology, Beijing Normal University, Beijing Radiation Center, Beijing 100875 (China)

    2009-01-15

    The reasons how the middle layer of Ru and Jun porcelain between the glaze and body came into being are still not completely understood. Here, elemental maps from the glaze to the body of pieces of ancient Chinese Ru and Jun porcelain were analyzed by micro-X-ray fluorescence. The results show the middle layer was probably formed by the chemical composition of the glaze turning into glassy states and undergoing complex physical-chemical reactions with the body. However, the middle layer of Jun porcelain was formed by the chemical composition of the glaze turning into glassy states and then infiltrating the body at high temperatures during the firing process.

  2. Analysis of elemental maps from glaze to body of ancient Chinese Jun and Ru porcelain by micro-X-ray fluorescence

    Science.gov (United States)

    Cheng, Lin; Li, Rongwu; Pan, Qiuli; Li, Guoxia; Zhao, Weijuan; Liu, Zhiguo

    2009-01-01

    The reasons how the middle layer of Ru and Jun porcelain between the glaze and body came into being are still not completely understood. Here, elemental maps from the glaze to the body of pieces of ancient Chinese Ru and Jun porcelain were analyzed by micro-X-ray fluorescence. The results show the middle layer was probably formed by the chemical composition of the glaze turning into glassy states and undergoing complex physical-chemical reactions with the body. However, the middle layer of Jun porcelain was formed by the chemical composition of the glaze turning into glassy states and then infiltrating the body at high temperatures during the firing process.

  3. Pathomorphological studies of the radiation syndrome in sheep after whole-body irradiation with X-rays

    International Nuclear Information System (INIS)

    Johannsen, U.; Mehlhorn, G.; Koch, F.; Panndorf, H.

    1978-01-01

    Eight one-year-old Merino mutton sheep were irradiated with X-ray doses of 380 R. Five of the animals died between the 16th and 25th day after irradiation and were examined. In organs and tissues a great diversity of pathological changes was observed as for instance hematopoietic disorders, septic processes, hemorrhagic diatheses, and partial epilation

  4. Fingerprinting analysis of non-crystalline pharmaceutical compounds using high energy X-rays and the total scattering pair distribution function

    Science.gov (United States)

    Davis, Timur D.

    2011-12-01

    In the development of new medicinal products, poor oral bioavailability, due to the low solubilities of many active pharmaceutical ingredients (APIs), is increasingly a barrier for treatments to be administered using tablet or capsule formulations and one of the main challenges facing the pharmaceutical industry. Non-crystalline phases such as the amorphous and nanostructured states can confer increased solubility to a drug, and therefore, have recently garnered a lot of interest from pharmaceutical researchers. However, little is known about local ordering in non-crystalline pharmaceuticals due to the lack of reliable experimental probes, hindering the clinical application of these compounds. The powerful tools of crystallography begin to lose their potency for structures on the nanoscale; conventional X-ray powder diffraction (XRPD) patterns become broad and featureless in these cases and are not useful for differentiating between different local molecular packing arrangements. In this thesis, we introduce the use of high energy X-rays coupled with total scattering pair distribution function (TSPDF) and fingerprinting analysis to investigate the local structures of non-crystalline pharmaceutical compounds. The high energy X-rays allow us to experimentally collect diffuse scattering intensities, which contain information about a sample's local ordering, in addition to the Bragg scattering available in conventional XRPD experiments, while the TSPDF allows us to view the intra- and inter-molecular correlations in real space. The goal of this study was to address some fundamental problems involving fingerprinting non-crystalline APIs using TSPDF in order to lay the groundwork for the proper use of the technique by the pharmaceutical community. We achieved this by developing the methodology as well as the exploring the scientific implications. On the methodology side, we introduced PDFGetX3, a new software program for calculating TSPDFs that simplifies the procedure

  5. Chest X-Ray

    Medline Plus

    Full Text Available ... some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a ... posted: How to Obtain and Share ...

  6. Chest X-Ray

    Medline Plus

    Full Text Available ... X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey Rubin, a radiologist ... about chest x-rays, visit Radiology Info dot org. Thank you for your time! Spotlight Recently posted: ...

  7. X-ray apparatus

    International Nuclear Information System (INIS)

    Sell, L.J.

    1981-01-01

    A diagnostic x-ray device, readily convertible between conventional radiographic and tomographic operating modes, is described. An improved drive system interconnects and drives the x-ray source and the imaging device through coordinated movements for tomography

  8. X-ray - skeleton

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003381.htm X-ray - skeleton To use the sharing features on this ... Degenerative bone conditions Osteomyelitis Risks There is low radiation exposure. X-rays machines are set to provide the smallest ...

  9. Characterization of tissues equivalent to the human body by the Monte Carlo method for X-rays

    International Nuclear Information System (INIS)

    Vega R, J.; Huamani T, Y.; Mullisaca P, A. F.; Yauri C, L.

    2017-10-01

    adipose tissue. The Pdp dosimetric analysis was performed with gamma radiation (Co-60) and high energy X-rays (6 MV). (Author)

  10. A structural investigation into the compaction behavior of pharmaceutical composites using powder X-ray diffraction and total scattering analysis.

    Science.gov (United States)

    Moore, Michael D; Steinbach, Alison M; Buckner, Ira S; Wildfong, Peter L D

    2009-11-01

    To use advanced powder X-ray diffraction (PXRD) to characterize the structure of anhydrous theophylline following compaction, alone, and as part of a binary mixture with either alpha-lactose monohydrate or microcrystalline cellulose. Compacts formed from (1) pure theophylline and (2) each type of binary mixture were analyzed intact using PXRD. A novel mathematical technique was used to accurately separate multi-component diffraction patterns. The pair distribution function (PDF) of isolated theophylline diffraction data was employed to assess structural differences induced by consolidation and evaluated by principal components analysis (PCA). Changes induced in PXRD patterns by increasing compaction pressure were amplified by the PDF. Simulated data suggest PDF dampening is attributable to molecular deviations from average crystalline position. Samples compacted at different pressures were identified and differentiated using PCA. Samples compacted at common pressures exhibited similar inter-atomic correlations, where excipient concentration factored in the analyses involving lactose. Practical real-space structural analysis of PXRD data by PDF was accomplished for intact, compacted crystalline drug with and without excipient. PCA was used to compare multiple PDFs and successfully differentiated pattern changes consistent with compaction-induced disordering of theophylline as a single component and in the presence of another material.

  11. Compositional Evolution of Calcium Silicate Hydrate (C-S-H) Structures by Total X-Ray Scattering

    KAUST Repository

    Soyer-Uzun, Sezen

    2011-12-09

    High-energy X-ray diffraction was employed to study the structural characteristics of a set of C-S-H samples with 0.6 ≤ C/S a;circ 1.75. It has been observed that Si is tetrahedrally coordinated to O for all samples irrespective of chemical composition and the Ca-O coordination number gradually decreases from ∼7 to ∼6 with increasing C/S ratio. This suggests that the C-S-H structure evolves from a tobermorite-like structure into a jennite-like structure as a function of increasing C/S ratio as the interlayer space decreases from ∼1.3 to ∼1 nm. Evolution of these short- and medium-range order structural characteristics in the C-S-H system is associated with the alteration of the Ca-O layers and silicate depolymerization with increasing C/S. © 2011 The American Ceramic Society.

  12. Compositional Evolution of Calcium Silicate Hydrate (C-S-H) Structures by Total X-Ray Scattering

    KAUST Repository

    Soyer-Uzun, Sezen; Chae, Sejung Rosie; Benmore, Chris J.; Wenk, Hans-Rudolf; Monteiro, Paulo J. M.

    2011-01-01

    High-energy X-ray diffraction was employed to study the structural characteristics of a set of C-S-H samples with 0.6 ≤ C/S a;circ 1.75. It has been observed that Si is tetrahedrally coordinated to O for all samples irrespective of chemical composition and the Ca-O coordination number gradually decreases from ∼7 to ∼6 with increasing C/S ratio. This suggests that the C-S-H structure evolves from a tobermorite-like structure into a jennite-like structure as a function of increasing C/S ratio as the interlayer space decreases from ∼1.3 to ∼1 nm. Evolution of these short- and medium-range order structural characteristics in the C-S-H system is associated with the alteration of the Ca-O layers and silicate depolymerization with increasing C/S. © 2011 The American Ceramic Society.

  13. Determination of ultra trace contaminants on silicon wafer surfaces using total-reflection X-ray fluorescence TXRF 'state-of-the-art'

    Science.gov (United States)

    Pahlke, S.; Fabry, L.; Kotz, L.; Mantler, C.; Ehmann, T.

    2001-11-01

    In a well balanced system of highly motivated, well trained personnel and automated equipment, pure reagents and bulk media, cleanrooms and integrated data management, total-reflection X-ray fluorescence (TXRF) can and must contribute to quality assurance and process stability, support and canalize creative engineering by continuous learning about materials and processes. TXRF has the advantage of controlled one-point calibration, a linear dynamic range of three orders of magnitude, high grade of automation in operation and data management, high up-time, and a simple control of data plausibility.

  14. Multielement determination in river-water of Sepetiba Bay tributaries (Brazil) by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Costa, A.C.M.; Castro, C.R.F.; Lopes, R.T.; Anjos, M.J.; Rio de Janeiro State Univ.

    2006-01-01

    Trace elements were determined in the surface waters of tributaries of the Sepetiba Bay, Brazil (Piraque, Ita, Sao Francisco, Guarda, Guandu Mirim, Vala do Sangue and Engenho Novo rivers) by total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). Eighteen trace elements could be determined in the dissolved and the suspended particulate phases: Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb. The elemental concentration values were compared to the values recommended by the Brazilian legislation. (author)

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... I’d like to talk with you about chest radiography also known as chest x-rays. Chest x-rays are the most ... far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot org. Thank you for your time! ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... you about chest radiography also known as chest x-rays. Chest x-rays are the most commonly performed ...

  17. National Health and Nutrition Examination Survey whole-body dual-energy X-ray absorptiometry reference data for GE Lunar systems.

    Science.gov (United States)

    Fan, Bo; Shepherd, John A; Levine, Michael A; Steinberg, Dee; Wacker, Wynn; Barden, Howard S; Ergun, David; Wu, Xin P

    2014-01-01

    The National Health and Nutrition Examination Survey (NHANES 1999-2004) includes adult and pediatric comparisons for total body bone and body composition results. Because dual-energy x-ray absorptiometry (DXA) measurements from different manufacturers are not standardized, NHANES reference values currently are applicable only to a single make and model of Hologic DXA system. The purpose of this study was to derive body composition reference curves for GE Healthcare Lunar DXA systems. Published values from the NHANES 1999-2004 survey were acquired from the Centers for Disease Control and Prevention website. Using previously reported cross-calibration equations between Hologic and GE-Lunar, we converted the total body and regional bone and soft-tissue measurements from NHANES 1999-2004 to GE-Lunar values. The LMS (LmsChartMaker Pro Version 3.5) curve fitting method was used to generate GE-Lunar reference curves. Separate curves were generated for each sex and ethnicity. The reference curves were also divided into pediatric (≤20 years old) and adult (>20 years old) groups. Adult reference curves were derived as a function of age. Additional relationships of pediatric DXA values were derived as a function of height, lean mass, and bone area. Robustness was tested between Hologic and GE-Lunar Z-score values. The NHANES 1999-2004 survey included a sample of 20,672 participants' (9630 female) DXA scans. A total of 8056 participants were younger than 20 yr and were included in the pediatric reference data set. Participants enrolled in the study who weighed more than 136 kg (over scanner table limit) were excluded. The average Z-scores comparing the new GE-Lunar reference curves are close to zero, and the standard deviation of the Z-scores are close to one for all variables. As expected, all measurements on the GE-Lunar reference curves for participants younger than 20 yr increase monotonically with age. In the adult population, most of the curves are constant at younger

  18. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy; Determinacion de plomo en esmaltado de barro por Fluorescencia de rayos X en reflexion total y Microscopia Electronica de Barrido

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua O, G.; Carapia M, L. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  19. Evaluation of heavy metals in atmospheric emissions from automotive industry by total reflection X-ray fluorescence with synchrotron radiation

    International Nuclear Information System (INIS)

    Moreira, Silvana; Weber Neto, Jose; Vives, Ana Elisa Sirito de

    2009-01-01

    This study had as goal to determine heavy metals and other elements (Ba, Br, Ca, Pb, Cl, Cr, Sr, Fe, Mn, Ni, K, Si, Ti and Zn) in atmospheric pollutants generated by an automotive industry located in the city of Engenheiro Coelho, state of Sao Paulo, Brazil. The sampling and sample preparation procedures were based on methods established by the Company of Sanitation and Technology (CETESB L9.234) and also by the Environmental Protection Agency (EPA - Method 29). The analysis was performed at XRF Beamline (D09B-XRF) in the Synchrotron Light Source Laboratory (Campinas/SP). A white beam of synchrotron radiation was used for sample and standard excitation which were irradiated by 100 seconds. For X-ray lines detection, a Ge (HP) detector with 150 eV of resolution at 5.9 keV was employed. For zinc, iron, barium, calcium and potassium, the values obtained were in the range of 30 mg/Nm 3 and, for other elements, the concentrations were approximately 1 mg/Nm 3 . The sum of As, Be, Co, Cr, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te and Zn concentration was compared with the limits established by CONAMA 264/1999 and SEMA 041/2002 resolutions (7.0 mg/Nm 3 ) and it was observed that, for all samples, sums are higher than the permissive value mainly due to the high concentration of zinc. Detection limits for SR-TXRF technique were 0.10 μg/Nm 3 for Pb and 0.02 μg/Nm 3 for Zn. (author)

  20. Evaluation of heavy metals in atmospheric emissions from automotive industry by total reflection X-ray fluorescence with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana; Weber Neto, Jose, E-mail: silvana@fec.unicamp.b [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Saneamento e Ambiente; Vives, Ana Elisa Sirito de, E-mail: aesvives@unimep.b [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo

    2009-07-01

    This study had as goal to determine heavy metals and other elements (Ba, Br, Ca, Pb, Cl, Cr, Sr, Fe, Mn, Ni, K, Si, Ti and Zn) in atmospheric pollutants generated by an automotive industry located in the city of Engenheiro Coelho, state of Sao Paulo, Brazil. The sampling and sample preparation procedures were based on methods established by the Company of Sanitation and Technology (CETESB L9.234) and also by the Environmental Protection Agency (EPA - Method 29). The analysis was performed at XRF Beamline (D09B-XRF) in the Synchrotron Light Source Laboratory (Campinas/SP). A white beam of synchrotron radiation was used for sample and standard excitation which were irradiated by 100 seconds. For X-ray lines detection, a Ge (HP) detector with 150 eV of resolution at 5.9 keV was employed. For zinc, iron, barium, calcium and potassium, the values obtained were in the range of 30 mg/Nm{sup 3} and, for other elements, the concentrations were approximately 1 mg/Nm{sup 3}. The sum of As, Be, Co, Cr, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te and Zn concentration was compared with the limits established by CONAMA 264/1999 and SEMA 041/2002 resolutions (7.0 mg/Nm{sup 3}) and it was observed that, for all samples, sums are higher than the permissive value mainly due to the high concentration of zinc. Detection limits for SR-TXRF technique were 0.10 mug/Nm{sup 3} for Pb and 0.02 mug/Nm{sup 3} for Zn. (author)

  1. Flash X-ray

    International Nuclear Information System (INIS)

    Sato, Eiichi

    2003-01-01

    Generation of quasi-monochromatic X-ray by production of weakly ionized line plasma (flash X-ray), high-speed imaging by the X-ray and high-contrast imaging by the characteristic X-ray absorption are described. The equipment for the X-ray is consisted from the high-voltage power supply and condenser, turbo molecular pump, and plasma X-ray tube. The tube has a long linear anticathode to produce the line plasma and flash X-ray at 20 kA current at maximum. X-ray spectrum is measured by the imaging plate equipped in the computed radiography system after diffracted by a LiF single crystal bender. Cu anticathode generates sharp peaks of K X-ray series. The tissue images are presented for vertebra, rabbit ear and heart, and dog heart by X-ray fluoroscopy with Ce anticathode. Generation of K-orbit characteristic X-ray with extremely low bremsstrahung is to be attempted for medical use. (N.I.)

  2. Total body irradiation

    International Nuclear Information System (INIS)

    Barrett, A.

    1988-01-01

    This paper describes body irradiation (TBI) being used increasingly as consolidation treatment in the management of leukaemia, lymphoma and various childhood tumours with the aim of sterilizing any malignant cells or micrometastases. Systemic radiotherapy as an adjunct to chemotherapy offers several possible benefits. There are no sanctuary sites for TBI; some neoplastic cells are very radiosensitive, and resistance to radiation appears to develop less readily than to drugs. Cross-resistance between chemotherapy and radiotherapy does not seem to be common and although plateau effects may be seen with chemotherapy there is a linear dose-response curve for clonogenic cell kill with radiation

  3. Use of dual-energy X-ray absorptiometry in obese individuals: The possibility to estimate whole body composition from DXA half-body scans

    International Nuclear Information System (INIS)

    Lundqvist, K.; Neovius, M.; Grigorenko, A.; Nordenstroem, J.; Roessner, S.

    2009-01-01

    Background: Because of its high accuracy, dual-energy X-ray absorptiometry (DXA) has become one of the most frequently used methods for estimating human body composition. One limiting factor concerning measuring obese people with the DXA technique is the size of the scanning area. Objective: To explore the possibility of estimating whole body composition from half-body scans before and after weight reduction, and compare the results with densitometry measurements. Design: Intervention study of 15 obese adults (age 47.2 ± 13.4; BMI 35.9 ± 3.1) who were measured with full- and half-body DXA scans before and after a 7-week weight loss program. On both occasions, body composition was also assessed with air-displacement plethysmography (ADP). Results: The mean weight loss at follow-up was 14.9 ± 4.1 kg (5.0 kg/m 2 ), corresponding to a 14% decrease in body weight. When comparing the results from full- and half-body DXA, between 96% and 98% of the variance was explained. At baseline, %Body Fat (%BF) did not differ significantly between full and half-body measurements (0.6, -0.1-1.3), but the half-body method overestimated it by 1.0% (0.2-1.8) at follow-up. On the contrary, the difference between DXA and ADP in the assessment of %BF was both significant and of large magnitude (5.2; 2.4-8.0) at baseline, while non-significant and near zero (0.4; -1.3-2.2) at follow-up when the subjects had lost a significant amount of weight. Conclusion: The results obtained from half-body DXA scans can accurately predict whole body composition, as measured by full-body DXA, before and after significant weight reduction, in obese patients who barely fit into the scanning area. However, increasing discordance between DXA and ADP with increasing adiposity was seen, indicating that the measurements might not be as reliable on extreme obese subjects as on normal and overweight ditto

  4. Use of dual-energy X-ray absorptiometry in obese individuals: The possibility to estimate whole body composition from DXA half-body scans

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, K. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)], E-mail: kent.lundqvist@karolinska.se; Neovius, M. [Obesity Unit, Department of Medicine, Karolinska Institutet, Karolinska University Hospital, SE-141 86 Stockholm (Sweden); Grigorenko, A. [Research and Development Unit, YLab Wellcare Institute, SE-113 60 Stockholm (Sweden); Nordenstroem, J. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Roessner, S. [Obesity Unit, Department of Medicine, Karolinska Institutet, Karolinska University Hospital, SE-141 86 Stockholm (Sweden)

    2009-02-15

    Background: Because of its high accuracy, dual-energy X-ray absorptiometry (DXA) has become one of the most frequently used methods for estimating human body composition. One limiting factor concerning measuring obese people with the DXA technique is the size of the scanning area. Objective: To explore the possibility of estimating whole body composition from half-body scans before and after weight reduction, and compare the results with densitometry measurements. Design: Intervention study of 15 obese adults (age 47.2 {+-} 13.4; BMI 35.9 {+-} 3.1) who were measured with full- and half-body DXA scans before and after a 7-week weight loss program. On both occasions, body composition was also assessed with air-displacement plethysmography (ADP). Results: The mean weight loss at follow-up was 14.9 {+-} 4.1 kg (5.0 kg/m{sup 2}), corresponding to a 14% decrease in body weight. When comparing the results from full- and half-body DXA, between 96% and 98% of the variance was explained. At baseline, %Body Fat (%BF) did not differ significantly between full and half-body measurements (0.6, -0.1-1.3), but the half-body method overestimated it by 1.0% (0.2-1.8) at follow-up. On the contrary, the difference between DXA and ADP in the assessment of %BF was both significant and of large magnitude (5.2; 2.4-8.0) at baseline, while non-significant and near zero (0.4; -1.3-2.2) at follow-up when the subjects had lost a significant amount of weight. Conclusion: The results obtained from half-body DXA scans can accurately predict whole body composition, as measured by full-body DXA, before and after significant weight reduction, in obese patients who barely fit into the scanning area. However, increasing discordance between DXA and ADP with increasing adiposity was seen, indicating that the measurements might not be as reliable on extreme obese subjects as on normal and overweight ditto.

  5. Synchrotron soft X-ray imaging and fluorescence microscopy reveal novel features of asbestos body morphology and composition in human lung tissues

    Directory of Open Access Journals (Sweden)

    Polentarutti Maurizio

    2011-02-01

    Full Text Available Abstract Background Occupational or environmental exposure to asbestos fibres is associated with pleural and parenchymal lung diseases. A histopathologic hallmark of exposure to asbestos is the presence in lung parenchyma of the so-called asbestos bodies. They are the final product of biomineralization processes resulting in deposition of endogenous iron and organic matter (mainly proteins around the inhaled asbestos fibres. For shedding light on the formation mechanisms of asbestos bodies it is of fundamental importance to characterize at the same length scales not only their structural morphology and chemical composition but also to correlate them to the possible alterations in the local composition of the surrounding tissues. Here we report the first correlative morphological and chemical characterization of untreated paraffinated histological lung tissue samples with asbestos bodies by means of soft X-ray imaging and X-Ray Fluorescence (XRF microscopy, which reveals new features in the elemental lateral distribution. Results The X-ray absorption and phase contrast images and the simultaneously monitored XRF maps of tissue samples have revealed the location, distribution and elemental composition of asbestos bodies and associated nanometric structures. The observed specific morphology and differences in the local Si, Fe, O and Mg content provide distinct fingerprints characteristic for the core asbestos fibre and the ferruginous body. The highest Si content is found in the asbestos fibre, while the shell and ferruginous bodies are characterized by strongly increased content of Mg, Fe and O compared to the adjacent tissue. The XRF and SEM-EDX analyses of the extracted asbestos bodies confirmed an enhanced Mg deposition in the organic asbestos coating. Conclusions The present report demonstrates the potential of the advanced synchrotron-based X-ray imaging and microspectroscopy techniques for studying the response of the lung tissue to the

  6. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  7. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Sirito de Vives, Ana Elisa [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil)]. E-mail: aesvives@unimep.br; Moreira, Silvana [State University of Campinas - UNICAMP/FEC (Brazil); Brienza, Sandra Maria Boscolo [School of Civil Engineering, Architecture and Urban Design Methodist University of Piracicaba, Rodovia Santa Barbara D' Oeste/Iracemapolis, km 01, 13450-000 Santa Barbara D' Oeste, SP (Brazil); Silva Medeiros, Jean Gabriel [University of Sao Paulo - USP/ ESALQ (Brazil); Tomazello Filho, Mario Tomazello [University of Sao Paulo - USP/ ESALQ (Brazil); Araujo Domingues Zucchi, Orgheda Luiza [University of Sao Paulo - USP/FCFRP (Brazil); Nascimento Filho, Virgilio Franco do [University of Sao Paulo - USP/CENA (Brazil)

    2006-11-15

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark.

  8. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Science.gov (United States)

    Wellenreuther, G.; Fittschen, U. E. A.; Achard, M. E. S.; Faust, A.; Kreplin, X.; Meyer-Klaucke, W.

    2008-12-01

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence (μXRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  9. Copper doped TiO2 nanoparticles characterized by X-ray absorption spectroscopy, total scattering, and powder diffraction--a benchmark structure-property study.

    Science.gov (United States)

    Lock, Nina; Jensen, Ellen M L; Mi, Jianli; Mamakhel, Aref; Norén, Katarina; Qingbo, Meng; Iversen, Bo B

    2013-07-14

    Metal functionalized nanoparticles potentially have improved properties e.g. in catalytic applications, but their precise structures are often very challenging to determine. Here we report a structural benchmark study based on tetragonal anatase TiO2 nanoparticles containing 0-2 wt% copper. The particles were synthesized by continuous flow synthesis under supercritical water-isopropanol conditions. Size determination using synchrotron PXRD, TEM, and X-ray total scattering reveals 5-7 nm monodisperse particles. The precise dopant structure and thermal stability of the highly crystalline powders were characterized by X-ray absorption spectroscopy and multi-temperature synchrotron PXRD (300-1000 K). The combined evidence reveals that copper is present as a dopant on the particle surfaces, most likely in an amorphous oxide or hydroxide shell. UV-VIS spectroscopy shows that copper presence at concentrations higher than 0.3 wt% lowers the band gap energy. The particles are unaffected by heating to 600 K, while growth and partial transformation to rutile TiO2 occur at higher temperatures. Anisotropic unit cell behavior of anatase is observed as a consequence of the particle growth (a decreases and c increases).

  10. Monitoring of the environmental pollution by trace element analysis in tree-rings using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Sirito de Vives, Ana Elisa; Moreira, Silvana; Brienza, Sandra Maria Boscolo; Silva Medeiros, Jean Gabriel; Tomazello Filho, Mario Tomazello; Araujo Domingues Zucchi, Orgheda Luiza; Nascimento Filho, Virgilio Franco do

    2006-01-01

    This paper aims to study the environmental pollution in the tree development, in order to evaluate its use as bioindicator in urban and country sides. The sample collection was carried out in Piracicaba city, Sao Paulo State, which presents high level of environmental contamination in water, soil and air, due to industrial activities, vehicles combustion, sugar-cane leaves burning in the harvesting, etc. The species Caesalpinia peltophoroides ('Sibipiruna') was selected because it is widely used in urban forestation. Synchrotron Radiation Total Reflection X-ray Fluorescence technique (SR-TXRF) was employed to identify and quantify the elements and metals of nutritional and toxicological importance in the wood samples. The analysis was performed in the Brazilian Synchrotron Light Source Laboratory, using a white beam for excitation and a Si(Li) detector for X-ray detection. In several samples, P, K, Ca, Ti, Fe, Sr, Ba and Pb were quantified. The K/Ca, K/P and Pb/Ca ratios were found to decrease towards the bark

  11. Optimizing total reflection X-ray fluorescence for direct trace element quantification in proteins I: Influence of sample homogeneity and reflector type

    Energy Technology Data Exchange (ETDEWEB)

    Wellenreuther, G. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Achard, M.E.S.; Faust, A.; Kreplin, X. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany); Meyer-Klaucke, W. [European Molecular Biology Laboratory, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: Wolfram@embl-hamburg.de

    2008-12-15

    Total reflection X-ray fluorescence (TXRF) is a very promising method for the direct, quick and reliable multi-elemental quantification of trace elements in protein samples. With the introduction of an internal standard consisting of two reference elements, scandium and gallium, a wide range of proteins can be analyzed, regardless of their salt content, buffer composition, additives and amino acid composition. This strategy also enables quantification of matrix effects. Two potential issues associated with drying have been considered in this study: (1) Formation of heterogeneous residues of varying thickness and/or density; and (2) separation of the internal standard and protein during drying (which has to be prevented to allow accurate quantification). These issues were investigated by microbeam X-ray fluorescence ({mu}XRF) with special emphasis on (I) the influence of sample support and (II) the protein / buffer system used. In the first part, a model protein was studied on well established sample supports used in TXRF, PIXE and XRF (Mylar, siliconized quartz, Plexiglas and silicon). In the second part we imaged proteins of different molecular weight, oligomerization state, bound metals and solubility. A partial separation of protein and internal standard was only observed with untreated silicon, suggesting it may not be an adequate support material. Siliconized quartz proved to be the least prone to heterogeneous drying of the sample and yielded the most reliable results.

  12. Nanoparticle-Assisted Scanning Focusing X-Ray Therapy with Needle Beam X Rays.

    Science.gov (United States)

    Davidson, R Andrew; Guo, Ting

    2016-01-01

    In this work, we show a new therapeutic approach using 40-120 keV X rays to deliver a radiation dose at the isocenter located many centimeters below the skin surface several hundred times greater than at the skin and how this dose enhancement can be augmented with nanomaterials to create several thousand-fold total dose enhancement effect. This novel approach employs a needle X-ray beam directed at the isocenter centimeters deep in the body while continuously scanning the beam to cover a large solid angle without overlapping at the skin. A Monte Carlo method was developed to simulate an X-ray dose delivered to the isocenter filled with X-ray absorbing and catalytic nanoparticles in a water phantom. An experimental apparatus consisting of a moving plastic phantom irradiated with a stationary 1 mm needle X-ray beam was built to test the theoretical predictions. X-ray films were used to characterize the dose profiles of the scanning X-ray apparatus. Through this work, it was determined that the X-ray dose delivered to the isocenter in a treatment voxel (t-voxel) underneath a 5 cm deep high-density polyethylene (HDPE) phantom was 295 ± 48 times greater than the surface dose. This measured value was in good agreement with the theoretical predicted value of 339-fold. Adding X-ray-absorbing nanoparticles, catalytic nanoparticles or both into the t-voxel can further augment the dose enhancement. For example, we predicted that adding 1 weight percentage (wp) of gold into water could increase the effective dose delivered to the target by onefold. Dose enhancement using 1 mm X-ray beam could reach about 1,600-fold in the t-voxel when 7.5 wp of 88 nm diameter silica-covered gold nanoparticles were added, which we showed in a previously published study can create a dose enhancement of 5.5 ± 0.46-fold without scanning focusing enhancement. Based on the experimental data from that study, mixing 0.02 wp 2.5 nm diameter small tetrakis hydroxymethyl phosphonium chloride (THPC

  13. Proton exciting X ray analysis

    International Nuclear Information System (INIS)

    Ma Xinpei

    1986-04-01

    The analyzing capability of proton exciting X ray analysis for different elements in organisms was discussed, and dealing with examples of trace element analysis in the human body and animal organisms, such as blood serum, urine, and hair. The sensitivity, accuracy, and capability of multielement analysis were discussed. Its strong points for the trace element analysis in biomedicine were explained

  14. Studies on the lipid peroxidation in mitochondria of x-ray whole-body irradiated rat liver, 2

    International Nuclear Information System (INIS)

    Wakabayashi, Hiroshi

    1976-01-01

    The results of investigation made on the mitochondria of rat liver on the 3rd day after irradiation of 650 R are as follows: After lipid peroxidation, the mitochondria showed a decrease of polyenoic acids (C-20:4, C-22:6) suggesting that polyenoic acids are the substrate of the reaction. Unsaturated fatty acids were decreased due to the decrement of C-18:1 and C-18:2, and polyenoic acid was relatively increased. These changes were transient, reaching a maximum on the 3rd day after irradiation. The rate of peroxidation in total lipids extracted form normal mitochondria was the same as that from whole-body irradiated mitochondria. There was no lag in the induction period in either reaction. Marked peroxidation of the total lipid was seen in the phospholipid fraction and slight peroxidation in the simple lipid fractions. No significant effect of whole-body irradiation on the peroxidation activities of the phospholipid was observed. With thin-layer chromatography, peroxidation of subfractionated phospholipid showed marked activity in the lecithin and aminophosphatide fractions containing large amounts of C-20:4 and C-22.6. Recovery of activity in the subfractions was greater than that in the total phospholipid. The effect of whole-body irradiation appeared to be significant in these subfractions. However no relationships could be seen between the activities peroxidation and the fatty acid composition of the subfractions. The ratio of phospholipid to total lipid increased in whole-body irradiated samples. From these findings there was a discussion of whether or not Fe ++ -induced lipid peroxidation at the mitochondrial level is due to change in the composition of fatty acid and the association of lipid in the membrane. (Evans, J.)

  15. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  16. Is whole body bone mineral density measured by the dual energy X-ray absorptiometry applied to evaluate risk of osteoporosis among Japanese adult females?

    International Nuclear Information System (INIS)

    Sakai, Yumiko; Koike, George; Numata, Makoto; Taneda, Kiyoshi; Jingu, Sumie

    2010-01-01

    The purpose of this study is to measure whole body fat accurately, the dual energy X-ray absorptiometry (DXA) is widely utilized. Simultaneously, bone mineral density (BMD) of the whole body can also be measured. BMD is one of important information to diagnose osteoporosis. However, it is not established to use whole body BMD for this diagnosis. It is recommended that lumbar and/or hip BMD should be used for diagnosing osteoporosis by the guideline for prevention and treatment of osteoporosis. Although it is possible to measure whole body BMD and lumbar and/or hip BMD separately at the same visit, it is inevitable to expose patients to more X-ray. Therefore, an aim of this study is to elucidate the relationship between whole body BMD and lumbar BMD to find the cut off point of whole body BMD for screening of osteoporosis. Two hundred and thirty six Japanese adult females were ascertained to this study. Whole body BMD and lumbar BMD of each subject were measured with the use of Delphi W (Hologic, USA). One hundred and sixty five subjects were judged as possible osteoporosis (less than 80% of young adult mean (YAM) of lumbar BMD and/or definite fracture of lumbar vertebras). The cut off point of whole body BMD for screening possible osteoporosis was estimated by receiver operated characteristic (ROC) analysis. The cut off point of whole body BMD was 84% of YAM, equivalent to 80% of YAM of lumbar BMD, with the following sensitivity and specificity (0.84 and 0.79, respectively), indicating that whole body BMD could be used for screening osteoporosis. (author)

  17. Providing x-rays

    International Nuclear Information System (INIS)

    Mallozzi, P.J.; Epstein, H.M.

    1985-01-01

    This invention provides an apparatus for providing x-rays to an object that may be in an ordinary environment such as air at approximately atmospheric pressure. The apparatus comprises: means (typically a laser beam) for directing energy onto a target to produce x-rays of a selected spectrum and intensity at the target; a fluid-tight enclosure around the target; means for maintaining the pressure in the first enclosure substantially below atmospheric pressure; a fluid-tight second enclosure adjoining the first enclosure, the common wall portion having an opening large enough to permit x-rays to pass through but small enough to allow the pressure reducing means to evacuate gas from the first enclosure at least as fast as it enters through the opening; the second enclosure filled with a gas that is highly transparent to x-rays; the wall of the second enclosure to which the x-rays travel having a portion that is highly transparent to x-rays (usually a beryllium or plastic foil), so that the object to which the x-rays are to be provided may be located outside the second enclosure and adjacent thereto and thus receive the x-rays substantially unimpeded by air or other intervening matter. The apparatus is particularly suited to obtaining EXAFS (extended x-ray fine structure spectroscopy) data on a material

  18. Near edge x-ray spectroscopy theory

    International Nuclear Information System (INIS)

    1994-01-01

    We propose to develop a quantitative theory of x-ray spectroscopies in the near edge region, within about 100 eV of threshold. These spectroscopies include XAFS (X-ray absorption fine structure), photoelectron diffraction (PD), and diffraction anomalous fine structure (DAFS), all of which are important tools for structural studies using synchrotron radiation x-ray sources. Of primary importance in these studies are many-body effects, such as the photoelectron self-energy, and inelastic losses. A better understanding of these quantities is needed to obtain theories without adjustable parameters. We propose both analytical and numerical calculations, the latter based on our x-ray spectroscopy codes FEFF

  19. Total and regional body-composition changes in early postmenopausal women

    DEFF Research Database (Denmark)

    Wang, Q; Hassager, C; Ravn, Pernille

    1994-01-01

    Total and regional body composition were measured in 373 early postmenopausal women aged 49-60 y by dual-energy x-ray absorptiometry to evaluate whether the changes in body composition in the early postmenopausal years are related to menopause itself or merely to age. Both fat mass and fat...

  20. Reproductive ability of female dogs (beagles) surviving a single, midlethal, whole-body x-ray exposure

    International Nuclear Information System (INIS)

    Andersen, A.C.; Rosenblatt, L.S.

    1976-01-01

    The ability of 82 irradiated and sham-treated female beagles to whelp and wean pups was tested over a major portion of their reproductive life span. The dogs were exposed to 290 or 300 R of x rays (250 kVp) either as young pups, prior to puberty, or at puberty. Although all of the irradiated dogs were fertile and produced approximately the same number of litters as controls, litters of the pup irradiated and prepubertal irradiated dams surviving throughout the study were smaller than those of controls by 17 and 9 percent, respectively. Pup survival was also reduced relative to controls; the number of pups weaned was 38 percent lower in the pup irradiated group and 18 percent lower in the prepubertal irradiated group, as compared with controls. The overall reproductive ability of dogs irradiated at puberty was similar to that of sham-treated controls

  1. Trace analysis in the atmosphere, water bodies and uranium ores by means of X-ray fluorescence

    International Nuclear Information System (INIS)

    Perez Novara, A.M.

    1986-01-01

    Analysis with X-ray fluorescence is an instrumental method that evaluates concentrations, at trace levels, of elements in samples of all kinds. The applications of this method are broad, specially useful in the analysis of metals as contaminators in air and water, and as impurities in minerals. The preparation of the samples is very important to obtain good accuracy, and at the same time, you should make a series of standards of known concentrations so you can compare the counting of each sample against the standard, for each of the elements. You should make, depending on the nature of the sample, several corrections with respect to the background, interferences, overlaps, or for effects of a third element. (author)

  2. Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection x-ray fluorescence spectrometry and secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Watanabe, Kazuo; Fukuyama, Hiroyasu; Onodera, Takashi; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu

    2004-01-01

    A new particle recovery method and a sensitive screening method were developed for subsequent isotope ratio analysis of uranium particles in safeguards swipe samples. The particles in the swipe sample were recovered onto a carrier by means of vacuum suction-impact collection method. When grease coating was applied to the carrier, the recovery efficiency was improved to 48±9%, which is superior to that of conventionally-used ultrasoneration method. Prior to isotope ratio analysis with secondary ion mass spectrometry (SIMS), total reflection X-ray fluorescence spectrometry (TXRF) was applied to screen the sample for the presence of uranium particles. By the use of Si carriers in TXRF analysis, the detection limit of 22 pg was achieved for uranium. By combining these methods with SIMS, the isotope ratios of 235 U/ 238 U for individual uranium particles were efficiently determined. (author)

  3. Application of the total reflection X-ray fluorescence method to the elemental analysis of brain tumors of different types and grades of malignancy

    International Nuclear Information System (INIS)

    Lankosz, M.W.; Grzelak, M.; Ostachowicz, B.; Wandzilak, A.; Szczerbowska-Boruchowska, M.; Wrobel, P.; Radwanska, E.; Adamek, D.

    2014-01-01

    The process of carcinogenesis may influence normal biochemical reactions leading to alterations in the elemental composition of the tissue. Total reflection X-ray fluorescence analysis (TXRF) was applied to the elemental analysis of different brain tumors. The following elements were present in all the neoplastic tissues analyzed: K, Ca, Fe, Cu, Zn and Rb. The results of the analysis showed that the elemental composition of a relatively small fragment of tissue represents satisfactorily the biochemical “signature” of a cancer. On the basis of the element concentrations determined, it was possible to differentiate between some types of brain tumors. - Highlights: • Elemental composition represents the biochemical signature of brain cancer. • The element levels differentiate some types of brain tumors. • TXRF spectrometry is a useful tool for elemental trace analysis of brain cancer

  4. Total L-shell X-ray production cross sections by 400-700 keV proton impact for elements with 34≤Z≤53

    International Nuclear Information System (INIS)

    Miranda, J.; Ledesma, R.; Lucio, O.G. de

    2001-01-01

    Total L-shell X-ray production cross sections induced by protons with energies between 400 and 700 keV were measured for elements with atomic number Z between 34 and 53. The ECPSSR theory describes appropriately the results. This model modifies the plane wave born approximation by considering projectile energy loss (E), Coulomb deflection of the incoming ion (C), polarization and change in electron binding energies through a perturbed stationary states method (PSS) and relativistic values of target electron mass (R). A comparison is given with previously published data for proton energies below 1 MeV and 26 ≤ Z ≤ 53, based on a scaling obtained from a reduced velocity parameter ξ L R . The results show that the scaling for these atomic numbers and energy ranges is adequate and a semi-empirical expression to calculate those cross sections is proposed

  5. Determination of the X-ray structure of the snake venom protein omwaprin by total chemical synthesis and racemic protein crystallography.

    Science.gov (United States)

    Banigan, James R; Mandal, Kalyaneswar; Sawaya, Michael R; Thammavongsa, Vilasak; Hendrickx, Antoni P A; Schneewind, Olaf; Yeates, Todd O; Kent, Stephen B H

    2010-10-01

    The 50-residue snake venom protein L-omwaprin and its enantiomer D-omwaprin were prepared by total chemical synthesis. Radial diffusion assays were performed against Bacillus megaterium and Bacillus anthracis; both L- and D-omwaprin showed antibacterial activity against B. megaterium. The native protein enantiomer, made of L-amino acids, failed to crystallize readily. However, when a racemic mixture containing equal amounts of L- and D-omwaprin was used, diffraction quality crystals were obtained. The racemic protein sample crystallized in the centrosymmetric space group P2(1)/c and its structure was determined at atomic resolution (1.33 A) by a combination of Patterson and direct methods based on the strong scattering from the sulfur atoms in the eight cysteine residues per protein. Racemic crystallography once again proved to be a valuable method for obtaining crystals of recalcitrant proteins and for determining high-resolution X-ray structures by direct methods.

  6. Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

    Science.gov (United States)

    Huang, Hsuan-Ming; Hsiao, Ing-Tsung

    2016-01-01

    In recent years, there has been increased interest in low-dose X-ray cone beam computed tomography (CBCT) in many fields, including dentistry, guided radiotherapy and small animal imaging. Despite reducing the radiation dose, low-dose CBCT has not gained widespread acceptance in routine clinical practice. In addition to performing more evaluation studies, developing a fast and high-quality reconstruction algorithm is required. In this work, we propose an iterative reconstruction method that accelerates ordered-subsets (OS) reconstruction using a power factor. Furthermore, we combine it with the total-variation (TV) minimization method. Both simulation and phantom studies were conducted to evaluate the performance of the proposed method. Results show that the proposed method can accelerate conventional OS methods, greatly increase the convergence speed in early iterations. Moreover, applying the TV minimization to the power acceleration scheme can further improve the image quality while preserving the fast convergence rate.

  7. Portable ultrahigh-vacuum sample storage system for polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo; Beniya, Atsushi; Isomura, Noritake [Toyota Central R& D Labs., Inc., Yokomichi 41-1, Nagakute, Aichi 480-1192 (Japan); Uehara, Hiromitsu; Asakura, Kiyotaka; Takakusagi, Satoru [Catalysis Research Center, Hokkaido University, Kita 21-10, Sapporo, Hokkaido 001-0021 (Japan); Nimura, Tomoyuki [AVC Co., Ltd., Inada 1450-6, Hitachinaka, Ibaraki 312-0061 (Japan)

    2016-03-15

    A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstrated by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.

  8. Wave-optical evaluation of interference fringes and wavefront phase in a hard-x-ray beam totally reflected by mirror optics.

    Science.gov (United States)

    Yamauchi, Kazuto; Yamamura, Kazuya; Mimura, Hidekazu; Sano, Yasuhisa; Saito, Akira; Endo, Katsuyoshi; Souvorov, Alexei; Yabashi, Makina; Tamasaku, Kenji; Ishikawa, Tetsuya; Mori, Yuzo

    2005-11-10

    The intensity flatness and wavefront shape in a coherent hard-x-ray beam totally reflected by flat mirrors that have surface bumps modeled by Gaussian functions were investigated by use of a wave-optical simulation code. Simulated results revealed the necessity for peak-to-valley height accuracy of better than 1 nm at a lateral resolution near 0.1 mm to remove high-contrast interference fringes and appreciable wavefront phase errors. Three mirrors that had different surface qualities were tested at the 1 km-long beam line at the SPring-8/Japan Synchrotron Radiation Research Institute. Interference fringes faded when the surface figure was corrected below the subnanometer level to a spatial resolution close to 0.1 mm, as indicated by the simulated results.

  9. Studies and developments for the analysis of products of nuclear reprocessing plants with the help of the X-ray fluorescence analysis on totally reflecting sample holders (TXRF)

    International Nuclear Information System (INIS)

    Diercks, H.; Eggers, I.; Gibau, F.; Haarich, M.; Hastenteufel, S.; Haurand, M.; Knoechel, A.; Salow, H.

    1990-01-01

    Studies with inactive and active simulates of products of nuclear reprocessing plants show the suitability of the X-Ray Fluorescence Analysis on Totally Reflecting Sample Holders (TXRF), to detect the available elements simultaneously by direct measurements of specially prepared thin samples. High dilution enables in the most cases, to avoid working in hot cells and to carry out the analysis in glove boxes. The analysis of uranium products and great amounts of matrix elements containing solutions like LAW and MAW demands the separation of the matrix elements before TXRF measurement. Procedures for this task have been developed. The potential of the new analytical procedure was demonstrated by the analysis of two samples of highly diluted high active wastes. (orig.) With 65 refs., 20 tabs., 81 figs [de

  10. Determination of metals by total reflection X-ray fluorescence and evaluation of toxicity of a river impacted by coal mining in the south of Brazil.

    Science.gov (United States)

    Lattuada, R M; Menezes, C T B; Pavei, P T; Peralba, M C R; Dos Santos, J H Z

    2009-04-30

    Metal (Fe, Mn, Zn, Ni, Cd, and Pb) concentrations in the region of Criciuma (Brazil), a region impacted by coal mining, were determined in water and sediments using total reflection X-ray fluorescence (TXRF) spectroscopy. Samples were collected from the Mãe Luzia River (south Brazil) at five different stations, from the source down to the river mouth (Ararangua estuary). Water and sediment toxicity were also evaluated using bioassays with Daphnia magna as the bioindicator. The metal present in the highest concentrations both in water (1.3-11 mg L(-1)) and in sediments (34-142 mg L(-1)) was iron. Results suggest an influence of coal mining on the aquatic receptors, showing a clear relationship between metal content (mostly Fe) and ecotoxicity.

  11. Use of high-intensity sonication for pre-treatment of biological tissues prior to multielemental analysis by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De La Calle, Inmaculada; Costas, Marta; Cabaleiro, Noelia; Lavilla, Isela; Bendicho, Carlos

    2012-01-01

    In this work, two ultrasound-based procedures are developed for sample preparation prior to determination of P, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se and Sr in biological tissues by total reflection X-ray fluorescence spectrometry. Ultrasound-assisted extraction by means of a cup-horn sonoreactor and ultrasonic-probe slurry sampling were compared with a well-established procedure such as magnetic agitation slurry sampling. For that purpose, seven certified reference materials and different real samples of animal tissue were used. Similar accuracy and precision is obtained with the three sample preparation approaches tried. Limits of detection were dependent on both the sample matrix and the sample pre-treatment used, best values being achieved with ultrasound-assisted extraction. Advantages of ultrasound-assisted extraction include reduced sample handling, decreased contamination risks (neither addition of surfactants nor use of foreign objects inside the extraction vial), simpler background (no solid particles onto the sample carrier) and improved recovery for some elements such as P. A mixture of 10% v/v HNO 3 + 20–40% v/v HCl was suitable for extraction from biological tissues. - Highlights: ► We implement high-intensity sonication for pre-treatment of biological tissues. ► Multielemental analysis is performed by total reflection X-ray spectrometry. ► Ultrasound-based procedures are developed and compared to conventional slurry preparation. ► Features such as background, recovery and sample handling are favored by using ultrasonic extraction.

  12. Room temperature trapping of stibine and bismuthine onto quartz substrates coated with nanostructured palladium for total reflection X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Vanesa; Costas-Mora, Isabel; Lavilla, Isela; Bendicho, Carlos, E-mail: bendicho@uvigo.es

    2015-05-01

    In this work, a novel method for determining Sb and Bi based on the trapping of their covalent hydrides onto quartz reflectors coated with immobilized palladium nanoparticles (Pd NPs) followed by total reflection X-ray fluorescence (TXRF) analysis is proposed. Pd NPs were synthesized by chemical reduction of the metal precursor using a mixture of water:ethanol as mild reducing agent. Silanization using 3-mercaptopropyltrimethoxysilane (MPTMS) was performed for the immobilization of Pd NPs onto the quartz substrates. Volatile hydrides (stibine and bismuthine) generated by means of a continuous flow system were flushed onto the immobilized Pd NPs and retained by catalytic decomposition. As a result of the high catalytic activity of the nanostructured film, trapping can be performed at ambient temperature with good efficiency. Limits of detection (LODs) were 2.3 and 0.70 μg L{sup −1} for Sb and Bi, respectively. Enrichment factors of 534 and 192 were obtained for Sb and Bi, respectively. The new method was applied for the analysis of several matrices (milk, soil, sediment, cutaneous powder). Recoveries were in the range of 98.4–101% for both elements with a relative standard deviation of 2.5% (N = 5). - Highlights: • A novel method for trapping covalent hydrides of antimony and bismuth is proposed. • Emphasis is placed on the application of Pd nanoparticles as trapping surface. • The nanostructured surface provides high catalytic activity at ambient temperature. • Analysis by total reflection X-ray fluorescence is performed. • Determination of Bi and Sb in different matrices is carried out.

  13. Analysis of nutrition-relevant trace elements in human blood and serum by means of total reflection X-ray fluorescence (TXRF) spectroscopy

    International Nuclear Information System (INIS)

    Stosnach, Hagen; Mages, Margarete

    2009-01-01

    In clinical service laboratories, one of the most common analytical tasks with regard to inorganic traces is the determination of the nutrition-relevant elements Fe, Cu, Zn, and Se. Because of the high numbers of samples and the commercial character of these analyses, a time-consuming sample preparation must be avoided. In this presentation, the results of total reflection X-ray fluorescence measurements with a low-power system and different sample preparation procedures are compared with those derived from analysis with common methods like Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The results of these investigations indicate that the optimal total reflection X-ray fluorescence analysis of the nutrition-relevant elements Fe, Cu, Zn, and Se can be performed by preparing whole blood and serum samples after dilution with ultrapure water and transferring 10 μl of internally standardized sample to an unsiliconized quartz glass sample carrier with subsequent drying in a laboratory oven. Suitable measurement time was found to be 600 s. The enhanced sample preparation by means of microwave or open digestion, in parts combined with cold plasma ashing, led to an improvement of detection limits by a factor of 2 for serum samples while for whole blood samples an improvement was only observed for samples prepared by means of microwave digestion. As the matrix elements P, S, Cl, and for whole blood Fe have a major influence on the detection limits, most probably a further enhancement of analytical quality requires the removal of the organic matrix. However, for the routine analysis of the nutrition-relevant elements, the dilution preparation was found to be sufficient.

  14. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  15. X-ray interferometers

    International Nuclear Information System (INIS)

    Franks, A.

    1980-01-01

    An improved type of amplitude-division x-ray interferometer is described. The wavelength at which the interferometer can operate is variable, allowing the instrument to be used to measure x-ray wavelength, and the angle of inclination is variable for sample investigation. (U.K.)

  16. X-rays utilization

    International Nuclear Information System (INIS)

    Rebigan, F.

    1979-03-01

    The modality of X-ray utilization in different activities and economy is given. One presents firstly quantities and units used in radiation dosimetry and other fields. One gives the generation of X-rays, their properties as well as the elements of radiation protection. The utilization characteristics of these radiations in different fields are finally given. (author)

  17. Chest X-Ray

    Medline Plus

    Full Text Available ... by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, ... d like to talk with you about chest radiography also known as chest x-rays. Chest x- ...

  18. Radiation therapy for angiosarcoma of the scalp: treatment outcomes of total scalp irradiation with X-rays and electrons.

    Science.gov (United States)

    Hata, Masaharu; Wada, Hidefumi; Ogino, Ichiro; Omura, Motoko; Koike, Izumi; Tayama, Yoshibumi; Odagiri, Kazumasa; Kasuya, Takeo; Inoue, Tomio

    2014-10-01

    Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy with total scalp irradiation. Four patients had cervical lymph node metastases, but none had distant metastases. A median initial dose of 50 Gy in 25 fractions was delivered to the entire scalp. Subsequently, local radiation boost to the tumor sites achieved a median total dose of 70 Gy in 35 fractions. Fourteen of the 17 patients developed recurrences during the median follow-up period of 14 months after radiation therapy; 7 had recurrences in the scalp, including primary tumor progression in 2 patients and new disease in 5, and 12 patients developed distant metastases. The primary progression-free, scalp relapse-free, and distant metastasis-free rates were 86, 67, and 38 % at 1 year and 86, 38, and 16 % at 3 years, respectively. Thirteen patients died; the overall and cause-specific survival rates were both 73 % at 1 year and 23 and 44 % at 3 years, respectively. The median survival time was 16 months. There were no therapy-related toxicities ≥ grade 3. Total scalp irradiation is safe and effective for local tumor control, but a dose of ≤ 50 Gy in conventional fractions may be insufficient to eradicate microscopic tumors. For gross tumors, a total dose of 70 Gy, and > 70 Gy for tumors with deep invasion, is recommended.

  19. The influence of body composition assessed by dual-energy x-ray absorptiometry on functional capacity of patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Gualberto Ruas

    Full Text Available INTRODUCTION: The individual with chronic obstructive pulmonary disease (COPD can experience a significant reduction of body composition, peripheral muscle dysfunction, resulting in a negative influence on functional capacity. OBJECTIVES: To analyze the influence of body composition assessed by dual-energy x-ray absorptiometry on functional capacity of patients with chronic obstructive pulmonary disease (COPD. MATERIALS AND METHODS: Eleven male patients with COPD (COPDG, seven presenting moderate obstruction and four severe, and 11 sedentary male subjects (CG were evaluated by dual-energy x-ray absorptiometry to assess their body composition. All subjects also performed the 6-minute walk test (6MWT and Step Test (6MST to assess their functional capacity. RESULTS: No significant differences were found between groups for anthropometric data such as age, weight, height and body mass index (BMI. However, the COPDG presented Forced Vital Capacity (FVC, Forced Expiratory Volume in one second (FEV1, FEV1/FVC ratio, Maximal Voluntary Ventilation (MVV, Walked Distance (WD and Number of Steps (NS significantly lower than the CG (p < 0.05, Student's t-test. The Body Bone Mass (BBM, BBM%, Lean Mass (LM, LM%, and Right Lower Limb (RLL and Left Lower Limb (LLL were significantly lower in the COPDG when compared with the CG, presenting statistically significant positive correlations with 6MWT's WD and 6MST's NS (p < 0.05, Pearson's test. CONCLUSION: We conclude that body composition is an important prognostic factor for patients with COPD, which reinforces the importance of assessing body composition by dual-energy absorptiometry since it has demonstrated with satisfactory accuracy in clinical practice. Moreover, it is a useful parameter for evaluation and reassessment in pulmonary rehabilitation programs.

  20. Comparison of Circumference Measures and Height-Weight Tables With Dual-Energy X-Ray Absorptiometry Assessment of Body Composition in R.O.T.C. Cadets.

    Science.gov (United States)

    Mitchell, Katherine M; Pritchett, Robert C; Gee, David L; Pritchett, Kelly L

    2017-09-01

    Mitchell, KM, Pritchett, RC, Gee, DL, and Pritchett, KL. Comparison of circumference measures and height-weight tables with dual-energy X-ray absorptiometry assessment of body composition in R.O.T.C. cadets. J Strength Cond Res 31(9): 2552-2556, 2017-Height-weight tables and circumference measures are used by the U.S. Army to predict body composition because they require little equipment or expertise. However, agreement between the Army's new 2002 circumference equation and an established laboratory technique has not been determined. The purpose of this study was to quantify agreement in body fat percentages between the Army's circumference measures (taping) and dual-energy X-ray absorptiometry (DXA); second to determine categorical agreement between height-weight tables and DXA. Male Reserve Officer Training Corps (R.O.T.C.) cadets (N = 23; 20.6 ± 1.6 years, 179.1 ± 6.6 cm; 81.4 ± 10.3 kg) were taped according to Army protocol to predict body fat. The % body fat prediction was compared with DXA through a Bland-Altman Plot with ±2-4% body fat established as a zone of agreement (ZOA). Thirteen out of 23 cadets fell outside the ZOA. No cadet was over the compliance threshold (20-22% fat) using the tape method, however, with DXA, 7 out of 23 cadets were noncompliant. Height-weight tables provided a moderate level of categorical agreement with DXA. The results depict poor agreement between taping and DXA, as taping generally underestimated % body fat. Compared with taping, height-weight tables were better able to identify excess fat weight.

  1. Constrained Total Generalized p-Variation Minimization for Few-View X-Ray Computed Tomography Image Reconstruction.

    Science.gov (United States)

    Zhang, Hanming; Wang, Linyuan; Yan, Bin; Li, Lei; Cai, Ailong; Hu, Guoen

    2016-01-01

    Total generalized variation (TGV)-based computed tomography (CT) image reconstruction, which utilizes high-order image derivatives, is superior to total variation-based methods in terms of the preservation of edge information and the suppression of unfavorable staircase effects. However, conventional TGV regularization employs l1-based form, which is not the most direct method for maximizing sparsity prior. In this study, we propose a total generalized p-variation (TGpV) regularization model to improve the sparsity exploitation of TGV and offer efficient solutions to few-view CT image reconstruction problems. To solve the nonconvex optimization problem of the TGpV minimization model, we then present an efficient iterative algorithm based on the alternating minimization of augmented Lagrangian function. All of the resulting subproblems decoupled by variable splitting admit explicit solutions by applying alternating minimization method and generalized p-shrinkage mapping. In addition, approximate solutions that can be easily performed and quickly calculated through fast Fourier transform are derived using the proximal point method to reduce the cost of inner subproblems. The accuracy and efficiency of the simulated and real data are qualitatively and quantitatively evaluated to validate the efficiency and feasibility of the proposed method. Overall, the proposed method exhibits reasonable performance and outperforms the original TGV-based method when applied to few-view problems.

  2. Estimation of stature and length of limb segments in children and adolescents from whole-body dual-energy X-ray absorptiometry scans

    International Nuclear Information System (INIS)

    Abrahamyan, Davit O.; Gazarian, Aram; Braillon, Pierre M.

    2008-01-01

    Anthropometric standards vary among different populations, and renewal of these reference values is necessary. To produce formulae for the assessment of limb segment lengths. Whole-body dual-energy X-ray absorptiometry scans of 413 Caucasian children and adolescents (170 boys, 243 girls) aged from 6 to 18 years were retrospectively analysed. Body height and the lengths of four long bones (humerus, radius, femur and tibia) were measured. The validity (concurrent validity) and reproducibility (intraobserver reliability) of the measurement technique were tested. High linear correlations (r > 0.9) were found between the mentioned five longitudinal measures. Corresponding linear regression equations for the most important relationships were derived. The tests of validity and reproducibility revealed a good degree of precision of the applied technique. The reference formulae obtained from the analysis of whole-body DEXA scans will be useful for anthropologists, and forensic and nutrition specialists, as well as for prosthetists and paediatric orthopaedic surgeons. (orig.)

  3. Speciation of copper and zinc in size-fractionated atmospheric particulate matter using total reflection mode X-ray absorption near-edge structure spectrometry

    International Nuclear Information System (INIS)

    Osan, Janos; Meirer, Florian; Groma, Veronika; Toeroek, Szabina; Ingerle, Dieter; Streli, Christina; Pepponi, Giancarlo

    2010-01-01

    The health effects of aerosol depend on the size distribution and the chemical composition of the particles. Heavy metals of anthropogenic origin are bound to the fine aerosol fraction (PM 2.5 ). The composition and speciation of aerosol particles can be variable in time, due to the time-dependence of anthropogenic sources as well as meteorological conditions. Synchrotron-radiation total reflection X-ray fluorescence (SR-TXRF) provides very high sensitivity for characterization of atmospheric particulate matter. X-ray absorption near-edge structure (XANES) spectrometry in conjunction with TXRF detection can deliver speciation information on heavy metals in aerosol particles collected directly on the reflector surface. The suitability of TXRF-XANES for copper and zinc speciation in size-fractionated atmospheric particulate matter from a short sampling period is presented. For high size resolution analysis, atmospheric aerosol particles were collected at different urban and rural locations using a 7-stage May cascade impactor having adapted for sampling on Si wafers. The thin stripe geometry formed by the particulate matter deposited on the May-impactor plates is ideally suited to SR-TXRF. Capabilities of the combination of the May-impactor sampling and TXRF-XANES measurements at HASYLAB Beamline L to Cu and Zn speciation in size-fractionated atmospheric particulate matter are demonstrated. Information on Cu and Zn speciation could be performed for elemental concentrations as low as 140 pg/m 3 . The Cu and Zn speciation in the different size fraction was found to be very distinctive for samples of different origin. Zn and Cu chemical state typical for soils was detected only in the largest particles studied (2-4 μm fraction). The fine particles, however, contained the metals of interest in the sulfate and nitrate forms.

  4. Multielement analysis of swiss mice brains with Alzheimer's disease induced by beta amyloid oligomers using a portable total reflection X-ray fluorescence system

    International Nuclear Information System (INIS)

    Almeida, Danielle S.; Brigido, Matheus M.; Anjos, Marcelino J.; Ferreira, Sergio S.; Souza, Amanda S.; Lopes, Ricardo T.

    2017-01-01

    Alzheimer's disease (AD) is a progressive dementia that, in early stages, manifests as a profound inability to form new memories. The pathological features of AD include β-amyloid (Aβ) plaques, intracellular neurofibrillary tangles, loss of neurons and synapses, and activation of glia cells. Recently, several groups have raised the 'metal hypothesis' of AD. Metal ions, such as Cu and Zn, have been demonstrated to modulate amyloid aggregation along different pathways. Extensive research has been conducted on the effects of metals on Aβ aggregation and all of them have shown that both Cu and Zn accelerate the aggregation by shortening, or eliminating, the lag phase associated with the amyloid fibrillation process. The metal ions mentioned previously may have an important impact on the protein misfolding and the progression of the neurodegenerative process. The TXRF technique is very important, because can be used to identify and quantify trace elements present in the sample at very low concentrations (μg.g"-"1). In this work, three groups of females were studied: control, AD10 and AD100. The groups AD10 and AD100 were given a single intracerebroventricular injection of 10 pmol and 100 pmol of oligomers of β-amyloid peptide respectively to be induced AD. The TXRF measurements were performed using a portable total reflection X-ray fluorescence system developed in the Laboratory of Nuclear Instrumentation (LIN/UFRJ) that uses an X-ray tube with a molybdenum anode operating at 40 kV and 500 mA used for the excitation and a detector Si-PIN with energy resolution of 145 eV at 200 eV. It was possible to determine the concentrations of the following elements: P, S, K, Fe, Cu, Zn and Rubidium. Results showed differences in the elemental concentration in some brain regions between the AD groups and the control group. (author)

  5. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Geraldo, Simoni Michetti; Canteras, Felippe Benavente

    2013-01-01

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g -1 considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  6. Evaluation of growth tree rings of Tipuana Tipu as biomonitoring of environmental pollution by synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana; Geraldo, Simoni Michetti; Canteras, Felippe Benavente, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com [Universidade Estadual de Campinas (FEC/UNICAMP), Campinas, SP (Brazil). Dept. de Saneamento e Ambiente

    2013-07-01

    The bioindicators, plants or animals capable to present qualitative and/or quantitative answers, when exposed to pollutant substances. Trees record and incorporate in their log, developed year after year, the impressions of the environment, becoming possible the study of the different environmental changes, including contamination, that have occurred over the life of these trees. The selected species, Tipuana Tipu, of the Leguminosae family, is native of Argentina and Bolivia and was introduced in Brazil as an ornamental plant. It is one of the most common trees in the urban landscaping in Sao Paulo city. The present project has as main objective the determination of the content of potentially toxic elements in samples of growth the tree rings of Tipuana Tipu, previously dated, collected in strategically locations of Sao Paulo, using Synchrotron Radiation Total Reflection X-Ray Fluorescence. Samples were also collected in the Piracicaba (SP), local of little access and small flow traffic. The SR-TXRF analysis was carried out in the X-ray Fluorescence Beamline at the Brazilian Synchrotron Light Source Laboratory, located in Campinas city, Sao Paulo State, Brazil. Some trace elements present concentrations higher than considered as normal in some periods. In this paper the highest value for Pb was 123.54 μg.g{sup -1} considered as threshold value was observed for the period 1998 to 2000 for University of Sao Paulo, Butanta site. For the same period excessive level was also observed for samples collected in Piracicaba city. In Sao Paulo city, sample collected in the campus of University of Sao Paulo (Butanta), showed the highest toxicity, with concentration above the tolerable limit for Ti, Cr and Cu. For the samples collected in Piracicaba city the concentrations of Cr, Ni, Cu, and Pb exceeding the toxicity limits. (author)

  7. Development of Total Reflection X-ray fluorescence spectrometry quantitative methodologies for elemental characterization of building materials and their degradation products

    Science.gov (United States)

    García-Florentino, Cristina; Maguregui, Maite; Marguí, Eva; Torrent, Laura; Queralt, Ignasi; Madariaga, Juan Manuel

    2018-05-01

    In this work, a Total Reflection X-ray fluorescence (TXRF) spectrometry based quantitative methodology for elemental characterization of liquid extracts and solids belonging to old building materials and their degradation products from a building of the beginning of 20th century with a high historic cultural value in Getxo, (Basque Country, North of Spain) is proposed. This quantification strategy can be considered a faster methodology comparing to traditional Energy or Wavelength Dispersive X-ray fluorescence (ED-XRF and WD-XRF) spectrometry based methodologies or other techniques such as Inductively Coupled Plasma Mass Spectrometry (ICP-MS). In particular, two kinds of liquid extracts were analysed: (i) water soluble extracts from different mortars and (ii) acid extracts from mortars, black crusts, and calcium carbonate formations. In order to try to avoid the acid extraction step of the materials and their degradation products, it was also studied the TXRF direct measurement of the powdered solid suspensions in water. With this aim, different parameters such as the deposition volume and the measuring time were studied for each kind of samples. Depending on the quantified element, the limits of detection achieved with the TXRF quantitative methodologies for liquid extracts and solids were set around 0.01-1.2 and 2-200 mg/L respectively. The quantification of K, Ca, Ti, Mn, Fe, Zn, Rb, Sr, Sn and Pb in the liquid extracts was proved to be a faster alternative to other more classic quantification techniques (i.e. ICP-MS), accurate enough to obtain information about the composition of the acidic soluble part of the materials and their degradation products. Regarding the solid samples measured as suspensions, it was quite difficult to obtain stable and repetitive suspensions affecting in this way the accuracy of the results. To cope with this problem, correction factors based on the quantitative results obtained using ED-XRF were calculated to improve the accuracy of

  8. Multielement analysis of swiss mice brains with Alzheimer's disease induced by beta amyloid oligomers using a portable total reflection X-ray fluorescence system

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Danielle S.; Brigido, Matheus M.; Anjos, Marcelino J.; Ferreira, Sergio S.; Souza, Amanda S.; Lopes, Ricardo T., E-mail: ricardo@lin.ufrj.br, E-mail: marcelin@uerj.br, E-mail: amandass@bioqmed.ufrj.br, E-mail: ferreira@bioqmed.ufrj.br, E-mail: amandass@bioqmed.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Instituto de Fisica Armando Dias Tavares (Brazil)

    2017-11-01

    Alzheimer's disease (AD) is a progressive dementia that, in early stages, manifests as a profound inability to form new memories. The pathological features of AD include β-amyloid (Aβ) plaques, intracellular neurofibrillary tangles, loss of neurons and synapses, and activation of glia cells. Recently, several groups have raised the 'metal hypothesis' of AD. Metal ions, such as Cu and Zn, have been demonstrated to modulate amyloid aggregation along different pathways. Extensive research has been conducted on the effects of metals on Aβ aggregation and all of them have shown that both Cu and Zn accelerate the aggregation by shortening, or eliminating, the lag phase associated with the amyloid fibrillation process. The metal ions mentioned previously may have an important impact on the protein misfolding and the progression of the neurodegenerative process. The TXRF technique is very important, because can be used to identify and quantify trace elements present in the sample at very low concentrations (μg.g{sup -1}). In this work, three groups of females were studied: control, AD10 and AD100. The groups AD10 and AD100 were given a single intracerebroventricular injection of 10 pmol and 100 pmol of oligomers of β-amyloid peptide respectively to be induced AD. The TXRF measurements were performed using a portable total reflection X-ray fluorescence system developed in the Laboratory of Nuclear Instrumentation (LIN/UFRJ) that uses an X-ray tube with a molybdenum anode operating at 40 kV and 500 mA used for the excitation and a detector Si-PIN with energy resolution of 145 eV at 200 eV. It was possible to determine the concentrations of the following elements: P, S, K, Fe, Cu, Zn and Rubidium. Results showed differences in the elemental concentration in some brain regions between the AD groups and the control group. (author)

  9. Radiation therapy for angiosarcoma of the scalp. Treatment outcomes of total scalp irradiation with X-rays and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Masaharu; Koike, Izumi; Kasuya, Takeo; Inoue, Tomio [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Wada, Hidefumi [Yokohama City University Graduate School of Medicine, Department of Dermatology, Yokohama, Kanagawa (Japan); Ogino, Ichiro [Yokohama City University Medical Center, Department of Radiation Oncology, Yokohama, Kanagawa (Japan); Omura, Motoko [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Shonankamakura General Hospital, Department of Radiation Oncology, Kamakura, Kanagawa (Japan); Tayama, Yoshibumi [Yokohama Minami Kyousai Hospital, Department of Radiology, Yokohama, Kanagawa (Japan); Odagiri, Kazumasa [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama, Kanagawa (Japan); Yokohama Municipal Citizen' s Hospital, Department of Radiation Oncology, Yokohama, Kanagawa (Japan)

    2014-10-15

    Wide surgical excision is the standard treatment for angiosarcoma of the scalp, but many patients are inoperable. Therefore, we investigated the outcome of radiation therapy for angiosarcoma of the scalp. Seventeen patients with angiosarcoma of the scalp underwent radiation therapy with total scalp irradiation. Four patients had cervical lymph node metastases, but none had distant metastases. A median initial dose of 50 Gy in 25 fractions was delivered to the entire scalp. Subsequently, local radiation boost to the tumor sites achieved a median total dose of 70 Gy in 35 fractions. Fourteen of the 17 patients developed recurrences during the median follow-up period of 14 months after radiation therapy; 7 had recurrences in the scalp, including primary tumor progression in 2 patients and new disease in 5, and 12 patients developed distant metastases. The primary progression-free, scalp relapse-free, and distant metastasis-free rates were 86, 67, and 38 % at 1 year and 86, 38, and 16 % at 3 years, respectively. Thirteen patients died; the overall and cause-specific survival rates were both 73 % at 1 year and 23 and 44 % at 3 years, respectively. The median survival time was 16 months. There were no therapy-related toxicities ≥ grade 3. Total scalp irradiation is safe and effective for local tumor control, but a dose of ≤ 50 Gy in conventional fractions may be insufficient to eradicate microscopic tumors. For gross tumors, a total dose of 70 Gy, and > 70 Gy for tumors with deep invasion, is recommended. (orig.) [German] Umfangreiche chirurgische Exzision ist die Standardbehandlung fuer Angiosarkome der Kopfhaut, aber viele Patienten sind nicht operierbar. Daher haben wir die Ergebnisse einer Strahlenbehandlung fuer Angiosarkome der Kopfhaut untersucht. Insgesamt 17 Patienten mit Angiosarkom der Kopfhaut erhielten eine Strahlenbehandlung der gesamten Kopfhaut. Vier Patienten hatten zervikale Lymphknotenmetastasen, aber keine Fernmetastasen. Die gesamte Kopfhaut

  10. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    Energy Technology Data Exchange (ETDEWEB)

    Tejeda, S. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Instituto Tecnologico de Toluca, Division de Estudios de Posgrado e Investigacion, Apartado Postal 890, Metepec, C.P. 52149 (Mexico); Zarazua, G., E-mail: graciela.zarazua@inin.gob.m [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Avila-Perez, P. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Instituto Tecnologico de Toluca, Division de Estudios de Posgrado e Investigacion, Apartado Postal 890, Metepec, C.P. 52149 (Mexico); Carapia-Morales, L. [Instituto Nacional de Investigaciones Nucleares, Gerencia de Ciencias Ambientales, Apartado Postal 18-1027, Mexico D.F., C.P. 11801 (Mexico); Martinez, T. [Universidad Nacional Autonoma de Mexico, Facultad de Quimica, Mexico D.F. (Mexico)

    2010-06-15

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth (Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn K{alpha}. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 {mu}g/g) > S (7593.3 {mu}g/g) > Fe (4406.6 {mu}g/g) > Ca (2601.8 {mu}g/g) > Mn (604.2 {mu}g/g) > Ti (230.7 {mu}g/g) > Zn (51.65 {mu}g/g) > Sr (43.55 {mu}g/g) > Rb (18.61 {mu}g/g) > Cu (12.78 {mu}g/g) > Cr (6.45 {mu}g/g) > Ni (4.68 {mu}g/g) > Pb (4.32 {mu}g/g) > Br (4.31 {mu}g/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  11. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    Science.gov (United States)

    Tejeda, S.; Zarazúa, G.; Ávila-Pérez, P.; Carapia-Morales, L.; Martínez, T.

    2010-06-01

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth ( Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn Kα. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 µg/g) > S (7593.3 µg/g) > Fe (4406.6 µg/g) > Ca (2601.8 µg/g) > Mn (604.2 µg/g) > Ti (230.7 µg/g) > Zn (51.65 µg/g) > Sr (43.55 µg/g) > Rb (18.61 µg/g) > Cu (12.78 µg/g) > Cr (6.45 µg/g) > Ni (4.68 µg/g) > Pb (4.32 µg/g) > Br (4.31 µg/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  12. Total reflection X-ray fluorescence spectrometric determination of elements in water hyacinth from the Lerma River

    International Nuclear Information System (INIS)

    Tejeda, S.; Zarazua, G.; Avila-Perez, P.; Carapia-Morales, L.; Martinez, T.

    2010-01-01

    The Lerma River is one of the most polluted body water in Mexico. For this reason, only the highly resistant organisms such as water hyacinth are able to reproduce in this river. The aim of this work was to evaluate the concentration of K, S, Fe, Ca, Mn, Ti, Zn, Sr, Rb, Cu, Cr, Ni, Pb and Br in roots of water hyacinth (Eichhornia crassipes) from the Lerma River. The samples were collected from five sites in the river and analyzed in triplicate using a TXRF Spectrometer 'TX-2000 Ital Structures' with a Si(Li) detector and a resolution of 140 eV (FWHM) at Mn Kα. A Mo tube (40 kV, 30 mA) with 17.4 KeV excitation energy was used for a counting time of 500 s. Results show that the average metal concentration in the water hyacinth roots decrease in the following order: K (9698.2 μg/g) > S (7593.3 μg/g) > Fe (4406.6 μg/g) > Ca (2601.8 μg/g) > Mn (604.2 μg/g) > Ti (230.7 μg/g) > Zn (51.65 μg/g) > Sr (43.55 μg/g) > Rb (18.61 μg/g) > Cu (12.78 μg/g) > Cr (6.45 μg/g) > Ni (4.68 μg/g) > Pb (4.32 μg/g) > Br (4.31 μg/g) and the bioconcentration factors in the water hyacinth decrease in the sequence: Ti > Fe > Mn > Cu > Ni > Zn > S > Pb > Rb > K > Cr > Sr > Br > Ca. The concentrations in roots of water hyacinth reflect the high pollution level of the river.

  13. Trace element analysis of mineral and tap water samples using total reflection x-ray fluorescence (TXRF)

    International Nuclear Information System (INIS)

    Mangala, M.J.; Korir, K.A.; Maina, D.M.; Kinyua, A.M.

    2000-01-01

    Results of trace element analysis by TXRF of tap water and various brands of bottled mineral water samples which are representative of local and imported brands sold in Nairobi are reported. The variation in elemental concentrations in water samples analyzed were as follows: potassium (K) 0.2 to 28.9 μg/ml; calcium (Ca) 2.2 to 120 μg/ml; titanium (Ti) 11 to 60 μg/l; manganese (Mn) 8 to 670 μg/l; iron (Fe) 31 to 540 μg/l; copper (Cu) 8 to 30 μg/l; zinc (Zn) 8 to 4730 μg/l; bromine (Br) 9 to 248 μg/l; rubidium (Rb) 10 to 40 μg/l and strontium (Sr) 10 to 1000 μg/l. Local mineral water samples contain higher levels of trace elements; manganese (Mn), zinc (Zn), bromine (Br), rubidium (Rb) and strontium (Sr) as compared to the imported brands. Principal component analysis of the results revealed three component loading factors clusters for: rubidium (Rb), strontium (Sr) and calcium (Ca); titanium (Ti), iron (Fe), bromine (Br), and zinc (Zn); zinc (Zn), manganese (Mn) and potassium (K) respectively. The percentage of total variance explained by the components was 31.4, 27.3, and 14.8 respectively. In this study, we also found that a limited spread of 5-6 mm for a 10 μl sample was achieved when the quartz sample carrier was dried in a low pressure (300 mbar) oven at 70 o C for 10 hours. (author)

  14. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  15. X-ray apparatus

    International Nuclear Information System (INIS)

    Bernstein, S.; Stagg, L.; Lambert, T.W.; Griswa, P.J.

    1976-01-01

    A patient support system for X-ray equipment in arteriographic studies of the heart is described in detail. The support system has been designed to overcome many of the practical problems encountered in using previous types of arteriographic X-ray equipment. The support system is capable of horizontal movement and, by a series of shafts attached to the main support system, the X-ray source and image intensifier or detector may be rotated through the same angle. The system is highly flexible and details are given of several possible operational modes. (U.K.)

  16. X-ray detector

    International Nuclear Information System (INIS)

    Whetten, N.R.; Houston, J.M.

    1977-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of x-ray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes. 8 figures

  17. X-ray apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1985-01-01

    X-ray apparatus is described which has a shutter between the X-ray source and the patient. The shutter controls the level of radiation to which the patient is exposed instead of merely discontinuing the electric power supplied to the source. When the shutter is opened a radiation sensor senses the level of X-radiation. When a preset quantity of X-radiation has been measured an exposure control closes the shutter. Instead of using the radiation sensor, the integrated power supplied to the anode of the X-ray source may be measured. (author)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  20. X-ray examination apparatus

    NARCIS (Netherlands)

    2000-01-01

    The invention relates to an X-ray apparatus which includes an adjustable X-ray filter. In order to adjust an intensity profile of the X-ray beam, an X-ray absorbing liquid is transported to filter elements of the X-ray filter. Such transport is susceptible to gravitational forces which lead to an

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  2. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  4. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  5. Percentage body fat by dual-energy X-ray absorptiometry is associated with menstrual recovery in adolescents with anorexia nervosa.

    Science.gov (United States)

    Pitts, Sarah; Blood, Emily; Divasta, Amy; Gordon, Catherine M

    2014-06-01

    To evaluate mediators of resumption of menses (ROM) in adolescents with anorexia nervosa (AN). Anthropometrics, body composition by dual-energy X-ray absorptiometry, hormonal studies, and responses to mental health screens were obtained at 6-month intervals for 18 months in 37 adolescents with AN randomized to the placebo arm of a double-blind treatment trial. Outcomes were compared between subjects with menstrual recovery and those without. Twenty-four subjects (65%) had ROM. Higher percentage body fat was associated with ROM (odds ratio, 1.19; 95% confidence interval, 1.06, 1.33; p adolescents with AN. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  6. X-ray Observations at Gaisberg Tower

    Directory of Open Access Journals (Sweden)

    Pasan Hettiarachchi

    2018-01-01

    Full Text Available We report the occurrence of X-rays at ground level due to cloud-to-ground flashes of upward-initiated lightning from Gaisberg Tower, in Austria, which is located at an altitude of 1300 m. This is the first observation of X-ray emissions from upward lightning from a tower top located at high altitude. Measurements were carried out using scintillation detectors installed close to the tower top in two phases from 2011 to 2015. X-rays were recorded in three subsequent strokes of three flashes out of the total of 108 flashes recorded in the system during both phases. In contrast to the observations from downward natural or triggered lightning, X-rays were observed only within 10 µs before the subsequent return stroke. This shows that X-rays were emitted when the dart leader was in the vicinity of the tower top, hence during the most intense phase of the dart leader. Both the detected energy and the fluence of X-rays are far lower compared to X-rays from downward natural or rocket-triggered lightning. In addition to the above 108 flashes, an interesting observation of X-rays produced by a nearby downward flash is also presented. The shorter length of dart-leader channels in Gaisberg is suggested as a possible cause of this apparently weaker X-ray production.

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... also be useful to help diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  9. X-ray tubes

    International Nuclear Information System (INIS)

    Young, R.W.

    1979-01-01

    A form of x-ray tube is described which provides satisfactory focussing of the electron beam when the beam extends for several feet from gun to target. Such a tube can be used for computerised tomographic scanning. (UK)

  10. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  11. Chest X-Ray

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... accurate diagnosis far outweighs any risk. For more information about chest x-rays, visit Radiology Info dot ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  13. Chest X-Ray

    Medline Plus

    Full Text Available ... Site Index A-Z Spotlight Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... exams and use a very small dose of ionizing radiation to produce pictures of the inside of the ... chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... However, it’s important to consider the likelihood of benefit to your health. While a chest x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs any risk. ...

  16. Chest X-Ray

    Medline Plus

    Full Text Available ... June is Men's Health Month Recently posted: Pancreatic Cancer The Limitations of Online Dose Calculators Video: The ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  17. Impact of hydration status on body composition as measured by dual energy X-ray absorptiometry in normal volunteers and patients on haemodialysis

    International Nuclear Information System (INIS)

    Horber, F.F.; Thomi, F.; Casez, J.P.; Fonteille, J.; Jaeger, Ph.

    1992-01-01

    To evaluate the influence of hydration status on the estimation of body composition using dual-energy X-ray absorptiometry (DXA), six normal volunteers and seven patients on maintenance haemodialysis were investigated using two different DXA machines (Lunar DPX, Hologic QDR 1000/W). Normal volunteers were studied (Hologic QDR 1000/W) before and 1 h after ingestion of breakfast, lunch and dinner (drinking various amounts of liquids at each meal, 0.5-2.4 kg). Whereas bone mineral content and body fat mass did not change, lean body mass of the trunk increased as a consequence of the meals. Conversely in patients on haemodialysis (Lunar DPX), lean body mass decreased in all segments of the body as a consequence of removal of 0.9-4.4 kg of salt-containing fluid by haemodialysis (trunk 61%, legs 30%, arms 5.5% and rest of the body 3.5%), whereas bone mineral content and body fat mass remained unchanged. (author)

  18. X-ray sources

    International Nuclear Information System (INIS)

    Masswig, I.

    1986-01-01

    The tkb market survey comparatively evaluates the X-ray sources and replacement tubes for stationary equipment currently available on the German market. It lists the equipment parameters of 235 commercially available X-ray sources and their replacement tubes and gives the criteria for purchase decisions. The survey has been completed with December 1985, and offers good information concerning medical and technical aspects as well as those of safety and maintenance. (orig.) [de

  19. Total body water and total body potassium in anorexia nervosa

    Energy Technology Data Exchange (ETDEWEB)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-08-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation.

  20. Total body water and total body potassium in anorexia nervosa

    International Nuclear Information System (INIS)

    Dempsey, D.T.; Crosby, L.O.; Lusk, E.; Oberlander, J.L.; Pertschuk, M.J.; Mullen, J.L.

    1984-01-01

    In the ill hospitalized patient with clinically relevant malnutrition, there is a measurable decrease in the ratio of the total body potassium to total body water (TBK/TBW) and a detectable increase in the ratio of total exchangeable sodium to total exchangeable potassium (Nae/Ke). To evaluate body composition analyses in anorexia nervosa patients with chronic uncomplicated semistarvation, TBK and TBW were measured by whole body K40 counting and deuterium oxide dilution in 10 females with stable anorexia nervosa and 10 age-matched female controls. The ratio of TBK/TBW was significantly (p less than 0.05) higher in anorexia nervosa patients than controls. The close inverse correlation found in published studies between TBK/TBW and Nae/Ke together with our results suggest that in anorexia nervosa, Nae/Ke may be low or normal. A decreased TBK/TBW is not a good indicator of malnutrition in the anorexia nervosa patient. The use of a decreased TBK/TBW ratio or an elevated Nae/Ke ratio as a definition of malnutrition may result in inappropriate nutritional management in the patient with severe nonstressed chronic semistarvation

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray examination. X-rays usually have no side effects in the typical diagnostic range for this exam. ... x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations to ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  6. Seasonal determination of trace and ultra-trace content in Macrocystis pyrifera from San Jorge Gulf (Patagonia) by Total Reflection X-ray Fluorescence

    Science.gov (United States)

    Salomone, Vanesa N.; Riera, Marina; Cerchietti, Luciana; Custo, Graciela; Muniain, Claudia

    2017-05-01

    Seaweed have a great capacity to accumulate heavy metals in their tissues. The chemical characterization of seaweed is important due to their use in environmental monitoring and human or animal food. The aim of the present study was to evaluate the multi-elemental composition of seaweed from San Jorge Gulf (Patagonia, Argentina) by Total Reflection X-ray Fluorescence (TXRF). The elements As, Br, Cu, Cr, Fe, Mn, Ni, Pb, Rb, Sr, V and Zn were seasonally analyzed and quantified in blades of Macrocystis pyrifera. TXRF showed to be a suitable technique for simultaneous multi-element analysis in this kind of samples. The results revealed seasonal variations in the chemical content for some elements; arsenic content was maximum in summer and autumn, iron concentration increased to the winter and zinc concentration was maximum in autumn. The sum of principal micronutrients (Fe + Zn + Mn + Cu) varied between 114 and 171 mg k- 1 g dw. The total As concentration ranged between 36 and 66 mg kg- 1. Lead, nickel and copper were not detected.

  7. A new Mumford-Shah total variation minimization based model for sparse-view x-ray computed tomography image reconstruction.

    Science.gov (United States)

    Chen, Bo; Bian, Zhaoying; Zhou, Xiaohui; Chen, Wensheng; Ma, Jianhua; Liang, Zhengrong

    2018-04-12

    Total variation (TV) minimization for the sparse-view x-ray computer tomography (CT) reconstruction has been widely explored to reduce radiation dose. However, due to the piecewise constant assumption for the TV model, the reconstructed images often suffer from over-smoothness on the image edges. To mitigate this drawback of TV minimization, we present a Mumford-Shah total variation (MSTV) minimization algorithm in this paper. The presented MSTV model is derived by integrating TV minimization and Mumford-Shah segmentation. Subsequently, a penalized weighted least-squares (PWLS) scheme with MSTV is developed for the sparse-view CT reconstruction. For simplicity, the proposed algorithm is named as 'PWLS-MSTV.' To evaluate the performance of the present PWLS-MSTV algorithm, both qualitative and quantitative studies were conducted by using a digital XCAT phantom and a physical phantom. Experimental results show that the present PWLS-MSTV algorithm has noticeable gains over the existing algorithms in terms of noise reduction, contrast-to-ratio measure and edge-preservation.

  8. The potential for portable X-ray fluorescence determination of soil copper at ancient metallurgy sites, and considerations beyond measurements of total concentrations.

    Science.gov (United States)

    Tighe, M; Rogan, G; Wilson, S C; Grave, P; Kealhofer, L; Yukongdi, P

    2018-01-15

    Copper (Cu) at ancient metallurgy sites represents the earliest instance of anthropogenically generated metal pollution. Such sites are spread across a wide range of environments from Eurasia to South America, and provide a unique opportunity to investigate the past and present extent and impact of metalworking contamination. Establishing the concentration and extent of soil Cu at archaeometallurgy sites can enhance archaeological interpretations of site use but can also, more fundamentally, provide an initial indication of contamination risk from such sites. Systematic evaluations of total soil Cu concentrations at ancient metalworking sites have not been conducted, due in part to the limitations of conventional laboratory-based protocols. In this paper, we first review what is known about Cu soil concentrations at ancient metallurgy sites. We then assess the benefits and challenges of portable X-ray fluorescence spectrometry (pXRF) as an alternative, rapid technique for the assessment of background and contaminant levels of Cu in soils. We conclude that pXRF is an effective tool for identifying potential contamination. Finally, we provide an overview of some major considerations beyond total Cu concentrations, such as bioavailability assessments, that will need to be considered at such sites to move toward a complete assessment of environmental and human risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Hard X-ray total scattering study on the structure of Si-dopped ferric oxyhydroxides and products of their transformation

    Science.gov (United States)

    Pieczara, Gabriela; Borkiewicz, Olaf; Manecki, Maciej; Rzepa, Grzegorz

    2016-04-01

    Here we report the results of a detailed structural investigation, using synchrotron-based pair distribution function analyses (PDF) and high-resolution X-ray diffraction (HR-XRD), on a series of Si-bearing synthetic analogues of ferrihydrite with a range of Si/Fe ratio relevant to geological environments and on products of their thermal transformation. Hard X-ray total scattering data suitable for PDF analyses have been collected at the PDF-dedicated beamline 11-ID-B and the HR-XRD data at beamline 11-BM of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). Ferrihydrite is a poorly crystalline, nano-sized hydrous ferric oxyhydroxide with a nominal/ideal formula Fe5HO8•4H2O. Its chemical composition however, can vary significantly and the atomic structure is yet to be fully understood despite multitude of structural studies undertaken over the past two decades (Michel et al., 2007; Manceau, 2009). One of the most commonly discussed and still unsettled contention points regarding the structural arrangements of ferrihydrite is related to the presence or absence of tetraherdally coordinated iron(III) within its structure. The majority of experimental work carried out to date focused on pure, synthetic ferrihydrite analogues with chemical composition close to ideal/nominal. This approach is clearly a significant oversimplification of natural ferrihydrite which always contains substantial amounts of admixtures, with Si, C, P, As, Ca, S and Al being the most common. One of the most important and the most commonly encountered impurities is Si, in the form of silicate ion that has strong affinity for ferrihydrite. SiO2content in natural ferrihydrites can vary substantially but generally falls with the range of 2.6-31.5 wt% (Cismasu et al., 2011). In certain environments however, such as modern seafloor hydrothermal vents, higher Si/Fe ratios (up to ca. 3) have been reported (Sun et al., 2013). The results of previous reports indicate that silicate

  10. Greater body mass independently predicts less radiographic progression on X-ray and MRI over 1-2 years

    DEFF Research Database (Denmark)

    Baker, Joshua F; Østergaard, Mikkel; George, Michael

    2014-01-01

    of radiographic progression for each BMI category (30 kg/m(2)). Within GO-BEFORE, piecewise, robust generalised estimating equations marginal models assessed the probability of MRI erosion progression for each BMI category. Multivariable linear regression models assessed baseline associations between......INTRODUCTION: Greater body mass index (BMI) has been associated with less radiographic progression in rheumatoid arthritis (RA). We evaluated the association between BMI and joint damage progression as measured by X-ray and MRI. METHODS: 1068 subjects with RA from two clinical trials of golimumab...... (GO-BEFORE and GO-FORWARD) had radiographs performed at weeks 0, 52 and 104 and evaluated using the van der Heijde-Sharp (vdHS) scoring system. Contrast-enhanced MRIs of the dominant wrist and hand were obtained at weeks 0, 12, 24, 52 and 104. Multivariable logistic regression evaluated the risk...

  11. Radioprotection by dipyridamole in the aging mouse. Effects on lipid peroxidation in mouse liver, spleen and brain after whole-body X-ray irradiation

    International Nuclear Information System (INIS)

    Seino, Noritaka

    1995-01-01

    To investigate the radioprotective effect of dipyridamole in the aging mouse, the lipid peroxide content in aging mouse liver, spleen and brain irradiated by X-ray were measured both before and after injection of dipyridamole. The lipid peroxide content increased with aging from 2 months old to 16 months old in the mouse liver, spleen and brain. The content of lipid peroxide in the liver and spleen of the aging mouse was significantly increased in 7 days after whole-body irradiation with 8 Gy, but was unchanged in the brain. Dipyridamole, given before irradiation, significantly inhibited the increase of lipid peroxide after irradiation. These results suggest that dipyridamole may have radioprotective effects on aging mouse liver and spleen as well as on young mouse, and that inhibition of lipid peroxidation is a possible factor in the radioprotective effect of dipyridamole. (author)

  12. Biofilms as bio-indicator for polluted waters? Total reflection X-ray fluorescence analysis of biofilms of the Tisza river (Hungary)

    Energy Technology Data Exchange (ETDEWEB)

    Mages, Margarete; Ovari, Mihaly; Tuempling, Wolf v. [Department of Inland Water Research Magdeburg, UFZ Centre for Environmental Research Leipzig-Halle, Brueckstrasse 3a, 39114, Magdeburg (Germany); Kroepfl, Krisztina [Department of Chemical Technology and Environmental Chemistry, Eoetvoes University, Pazmany Peter setany 1/A, 1117, Budapest (Hungary)

    2004-02-01

    The aim of this work was to investigate the heavy metal accumulation by natural biofilms living in the catchment area of the Tisza river in Hungary, as well as in biofilms cultivated in vitro. Laboratory tests have demonstrated that metals can be adsorbed on biofilms, depending on their concentration and on the availability of free sorptive places. Biofilms were cultivated in vitro in natural freshwater from the Saale river, Germany. After reaching the plateau phase, Cu was added to reach a concentration of 100 {mu}g/L. An increase of its mass fraction in the biofilm was observed, which caused the decrease of the concentration in the water phase. Unfortunately, the reactor wall was also found to act as adsorbent for Cu. More detailed results of our in vitro experiments will be published in a forthcoming paper. Naturally grown biofilm samples from exposed as well as background places at the Hungarian rivers Szamos and Tisza were collected in 2000 and 2002 after the cyanide spill, and analysed using total reflection X-ray fluorescence analysis (TXRF). Metal mass fraction differences as high as two orders of magnitude were found between polluted and unpolluted (background) sampling points. Extremely high concentration values, e.g. 5600 {mu}g/g Zn in biofilm, were found at highly polluted sampling points. This means an enrichment factor of ca. 10,000 compared to the water phase. (orig.)

  13. Total reflection X-ray fluorescence measurements of S and P in proteins using a vacuum chamber specially designed for low Z elements

    International Nuclear Information System (INIS)

    Rauwolf, M.; Vanhoof, C.; Tirez, K.; Maes, E.; Ingerle, D.; Wobrauschek, P.; Streli, C.

    2014-01-01

    As the ratio of phosphorus and sulfur in proteins allows the determination of the phosphorylation degree in proteins, the absolute determination of phosphorus and sulfur in organic samples is of growing interest. While it takes some effort to quantify phosphorus and sulfur with inductively coupled quadrupole plasma mass spectrometry (ICP-QMS), total reflection X-ray fluorescence analysis (TXRF) allows easy quantification. In the presented work, the low Z TXRF spectrometer at the Atominstitut was used to analyze phosphorus and sulfur in proteins. Although the preparation of the protein samples proved to be more difficult than originally expected, it could be shown that TXRF is well suited for the determination of P and S in proteins. The obtained lower limits of detection (LLD) for P and S in proteins were extrapolated for 1000s and were 34 pg and 19 pg, respectively. The importance of height scans for each sample to exclude heterogeneities was demonstrated. - Highlights: • Low Z TXRF spectrometry was used to analyze phosphorus and sulfur in proteins. • TXRF is well suited for the determination of P and S in proteins. • Good detection limits for P (34 pg) and S (19 pg) were achieved. • Due to the detection limits, we propose that TXRF is a suitable method to analyze protein fractions

  14. Effect of modulation of the particle size distributions in the direct solid analysis by total-reflection X-ray fluorescence

    Science.gov (United States)

    Fernández-Ruiz, Ramón; Friedrich K., E. Josue; Redrejo, M. J.

    2018-02-01

    The main goal of this work was to investigate, in a systematic way, the influence of the controlled modulation of the particle size distribution of a representative solid sample with respect to the more relevant analytical parameters of the Direct Solid Analysis (DSA) by Total-reflection X-Ray Fluorescence (TXRF) quantitative method. In particular, accuracy, uncertainty, linearity and detection limits were correlated with the main parameters of their size distributions for the following elements; Al, Si, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb. In all cases strong correlations were finded. The main conclusion of this work can be resumed as follows; the modulation of particles shape to lower average sizes next to a minimization of the width of particle size distributions, produce a strong increment of accuracy, minimization of uncertainties and limit of detections for DSA-TXRF methodology. These achievements allow the future use of the DSA-TXRF analytical methodology for development of ISO norms and standardized protocols for the direct analysis of solids by mean of TXRF.

  15. Multielement analysis of environmental samples by total-reflection X-ray fluorescence sprectrometry, neutron activation analysis and inductively coupled plasma optical emission spectroscopy

    International Nuclear Information System (INIS)

    Michaelis, W.

    1986-01-01

    In environmental research and protection trace elements have to be determined over a wide range of atomic number, down to very low concentrations, and in quite different matrices. This challenge requires the availability of complementary analytical methods characterized by a high detection power and few sources of systematic errors. Besides, the capacity of multielement detection is often desired since it facilitates the talking of many problems in which numerous trace elements are of direct concern. Total-reflection X-ray fluorescence, neutron activation analysis and inductively coupled plasma optical emission spectroscopy, in principle fulfill these requirements quite well. However, each method has its domain, and the application to certain sample species may be less promising. Under this aspect, the paper summarizes some recent developments and investigations, including intercomparisons as far as possible. Various matrices are considered : rainwater and airborne particulates, soil samples, river sediments and suspended particulate matter, river water filtrates, ozean water, and organic matrices. Capabilities and limitations are discussed. Sample preparation techniques are described if they are new or essential for achieving the results given. (orig.) [de

  16. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luciana Carla Ferreira de; Canteras, Felippe Benavente; Moreira, Silvana, E-mail: silvana@fec.unicamp.br, E-mail: felippe.canteras@gmail.com, E-mail: lucarla24@gmail.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Inst. Politecnico. Dept. de Saneamento e Ambiente

    2013-07-01

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  17. Mineral elements and essential trace elements in blood of seals of the North Sea measured by total-reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Griesel, S.; Mundry, R.; Kakuschke, A.; Fonfara, S.; Siebert, U.; Prange, A.

    2006-01-01

    Mineral and essential trace elements are involved in numerous physiological processes in mammals. Often, diseases are associated with an imbalance of the electrolyte homeostasis. In this study, the concentrations of mineral elements (P, S, K, Ca) and essential trace elements (Fe, Cu, Zn, Se, Rb, Sr) in whole blood of harbor seals (Phoca vitulina) were determined using total-reflection X-ray fluorescence spectrometry (TXRF). Samples from 81 free-ranging harbor seals from the North Sea and two captive seals were collected during 2003-2005. Reference ranges and element correlations for health status determination were derived for P, S, K, Ca, Fe, Cu, and Zn level in whole blood. Grouping the seals by age, gender and sample location the concentration levels of the elements were compared. The blood from two captive seals with signs of diseases and four free-ranging seals showed reduced element levels of P, S, and Ca and differences in element correlation of electrolytes were ascertained. Thus, simultaneous measurements of several elements in only 500 μL volumes of whole blood provide the possibility to obtain information on both, the electrolyte balance and the hydration status of the seals. The method could therefore serve as an additional biomonitoring tool for the health assessment

  18. Analysis in crab tissues and in sediment of estuary from Iguape (Sao Paulo, Brazil) by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Salvador, Marcos J.; Sawazaki, David T.A.; Zucchi, Orgheda L.A. Domingues; Vives, Ana Elisa S. de; Hattori, Gustavo Y.

    2007-01-01

    We report the use of Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF) as a technique for macro, micro and trace elements determination in the tissues of the crab Ulcides cordatus and in the sediments from the Iguape estuary (Sao Paulo, Brazil) for environmental pollution control and toxicological evaluation. The analyses were performed on the U. cordatus (muscles and hepatopancreas) and on sediments from 24 sites of the Iguape estuary (Sao Paulo, Brazil). Tissues and sediments samples were analyzed by SRTXRF after digestion in an open system, using Ga as internal standard. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr, and Ba were the elements detected in crab hepatopancreas at concentration ranging from 0.516 (Mn) to 2061 (K) mug/g. Muscles samples presented the elements K, Ca, Ti, V, Cr, Fe, Ni, Cu, Zn, Br and Sr at concentrations ranging from 0.043 (Ni) to 1917 (K) mug/g. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Sn, Ce, and Pb were the elements detected in the sediment samples with concentration between 3.8 (Cu) and 14628 (Fe)mug/g. (author)

  19. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  20. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    International Nuclear Information System (INIS)

    Martinez, T.; Zarazua, G.; Avila-Perez, P.; Juarez, F.; Cabrera, L.; Martinez, G.

    2008-01-01

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 μL min -1 . Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals

  1. Analysis of heavy metals and minerals elements in the turmeric using Total-Reflection X-ray Fluorescence analysis technique and Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Andriamisetra, V.M.Z.

    2014-01-01

    Currently, many studies demonstrate anti-cancer and anti-inflammatory benefits of turmeric. The aims of this work is to perform analysis of metals such as calcium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, bromine, rubidium, strontium, cadmium and lead in the turmeric collected from various places in Madagascar. The analysis by total reflection X-ray fluorescence technique is used to determine the concentrations of heavy metals, while the atomic absorption spectrometry is used for the determination of trace elements. Analysis results show that the concentration of calcium in the turmeric is very high, its average concentration is 1025.8 mg.kg -1 . The average concentrations of manganese, of copper and of iron are respectively 44.7 mg.kg -1 ; 19.7 mg.kg -1 and 53.6 mg.kg -1 . The average concentrations of zinc, of rubidium and of strontium are respectively 17.3 mg.kg -1 ; 35.2 mg.kg -1 and 21.7 mg.kg -1 [fr

  2. Characterization by Total Reflection X-ray Fluorescence Spectrometry of filtered water into the cave under the Sun Pyramid in Teotihuacan City

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, T. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico)], E-mail: tmc@servidor.unam.mx; Zarazua, G.; Avila-Perez, P. [National Institute of Nuclear Research, Carr. Mexico-Toluca Km 36.5, 52045, Salazar, Ocoyoacac, Edo. de Mexico (Mexico); Juarez, F. [National University of Mexico, Institute of Geophysics, Circuito Institutos, CU, 04510 Mexico, D.F. (Mexico); Cabrera, L. [National University of Mexico, Faculty of Chemistry, Building D, CU, O4510, Mexico, D.F. (Mexico); Martinez, G. [Coordinacion Nacional de Conservacion del Patrimonio Cultural, Xicotencatl y General Anaya s/n., 04120, Mexico, D.F. (Mexico)

    2008-12-15

    Teotihuacan (50 km north-east Mexico City) was the most important ancient city in Mesoamerica and it flourished 200-750 AC. It is situated in the central part of the Valley of Teotihuacan, in Central Mexico. This study was carried out in the 102 m-long cave under the largest single construction, the massive Sun Pyramid, being located on the east side of the 'Avenue of the Dead', in the northern half-part of the city. The study shows the results of Total Reflection X-ray Fluorescence Spectrometry analysis and other techniques of a water sample obtained from the inside of the cave. The inside temperature ranged between 19 and 22 deg. C; relative humidity was between 98 and 99.3%; water-dropping velocity (water de-sorption capability) was 13.5 {mu}L min{sup -1}. Water samples from wells around the site were analyzed too. Metal concentration in all of the water samples matches the characteristics of the sampling site, well's depth, soil and minerals.

  3. Quantification of potentially toxic elements in sewage and sludge from treatment plants in the cities of Campinas and Jaguariuna using synchrotron radiation total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Souza, Luciana Carla Ferreira de; Canteras, Felippe Benavente; Moreira, Silvana

    2013-01-01

    The rapid urban and industrial development in last decades has brought as one of the consequences, changes in the environment. The lack of planning of city growth is, today, one of the major causes of water pollution including residential, industrial, agricultural, and hospital waste. The metals contamination is a major problem, causing serious changes to the environment, causing harm to human health. The sludge generated at sewage treatment plants, is an important source of nutrients and organic matter, and therefore it can also be reused mainly for agricultural use, since contaminants are removed. The cities of Campinas and Jaguariuna are inserted in the Campinas Metropolitan Region (CMR), one of the most dynamic regions in the Brazilian economy. Therefore, to study the anthropogenic influences of the cities, evaluated the quality of raw and treated effluent and the sludge generated in sewage treatment plants, especially with regard to heavy metals. Measurements of metals were performed by Synchrotron Radiation Total Reflection X-ray Fluorescence. For treated effluent data were compared to CONAMA 357 law and Cr, Mn, Fe, Ni, Cu, Zn, Ba and Pb showed concentrations in according with the law. To reuse in agriculture the contents were compared to the limits defined by CETESB and some elements had concentrations above to the permitted preventing its reuse. For sludge, Cr, Ni, Cu, Zn, Ba and Pb, in the two treatment plants studied, the concentrations were lower than the maximum permissible values established by CONAMA 375 law allowing the sludge application sludge on agricultural land. (author)

  4. Biomonitoring of environmental pollution using growth tree rings of Tipuana tipu: Quantification by synchrotron radiation total reflection X-ray fluorescence

    Science.gov (United States)

    Geraldo, S. M.; Canteras, F. B.; Moreira, S.

    2014-02-01

    Currently, many studies use the bioindicators to qualitatively and/or quantitatively measure pollution. The analyses of tree growth rings represent one such bioindicator as changes in the environment are often recorded as impressions in the wood. The main objective of the present study is to examine the growth rings of Tipuana tipu - a member of the Leguminosae family that is native to Argentina and Bolivia and was introduced in Brazil as an ornamental plant - for potentially toxic elements. T. tipu is one of the most common trees in the urban landscape of Sao Paulo city and would provide an accurate reflection of environment changes. Tree ring samples previously dated using Synchrotron Radiation Total Reflection X-ray Fluorescence were collected from strategic locations in Sao Paulo. These locations include Piracicaba (SP) that has little access and small flow traffic and the campus of the University of São Paulo. Some trace elements present concentrations higher than considered as normal in some periods. In São Paulo city, samples collected from the campus of University of São Paulo (Butantã), showed the highest toxicity, with concentrations above the tolerable limit for the elements: Cr, Cu, and Pb. For the samples collected in Piracicaba city, one sample presented highest concentrations for the majority of the elements when compared to the other four samples collected at the same place, exceeding the toxicity limits for: Cr, Ni, Cu, and Pb.

  5. Analysis in crab tissues and in sediment of estuary from Iguape (Sao Paulo, Brazil) by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Salvador, Marcos J. [Universidade do Vale do Paraiba (UNIVAP), Sao Jose dos Campos, SP (Brazil)], E-mail: mjsalvador1531@yahoo.com.br; Sawazaki, David T.A.; Zucchi, Orgheda L.A. Domingues [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas], E-mail: david_tatsuo@hotmail.com, E-mail: olzucchi@fcfrp.usp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo], E-mail: aesvives@unimep.br; Hattori, Gustavo Y. [Universidade Federal do Amazonas, Benjamin Constant (Brazil). Faculdade de Ciencias Agrarias], E-mail: hattori@ufam.edu.br

    2007-07-01

    We report the use of Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF) as a technique for macro, micro and trace elements determination in the tissues of the crab Ulcides cordatus and in the sediments from the Iguape estuary (Sao Paulo, Brazil) for environmental pollution control and toxicological evaluation. The analyses were performed on the U. cordatus (muscles and hepatopancreas) and on sediments from 24 sites of the Iguape estuary (Sao Paulo, Brazil). Tissues and sediments samples were analyzed by SRTXRF after digestion in an open system, using Ga as internal standard. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Sr, and Ba were the elements detected in crab hepatopancreas at concentration ranging from 0.516 (Mn) to 2061 (K) mug/g. Muscles samples presented the elements K, Ca, Ti, V, Cr, Fe, Ni, Cu, Zn, Br and Sr at concentrations ranging from 0.043 (Ni) to 1917 (K) mug/g. Potassium (K), Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr, Sn, Ce, and Pb were the elements detected in the sediment samples with concentration between 3.8 (Cu) and 14628 (Fe)mug/g. (author)

  6. Clinical X-ray characteristics of some forms of hematogenous vertebral body osteomyelitis in children and adolescents

    International Nuclear Information System (INIS)

    Sizov, V.A.

    1988-01-01

    Clinico-roentgenological changes in dynamics are studied in 72 children and adolescents with a limited hematogenous vertebrae body osteomyelitis. The clinico-roentgenologic examination lasted from 1 to 15 years. Such a durable examination permitted to trace the development, regularities and remote results of the disease. The increase in vertebrae body height (lengthening) which is considered a pathognomonic sign of tuberculous spondylitis is described for the first time. Unlike tuberculosis, hematogenous spondylitis brings about the body lengthening of both ajacent nonaffected and affected vertebrae in the case of their surface or limited focal injury. 12 refs.; 1 fig

  7. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  8. Watching Nanoparticles Form: An In Situ (Small-/Wide-Angle X-ray Scattering/Total Scattering) Study of the Growth of Yttria-Stabilised Zirconia in Supercritical Fluids

    DEFF Research Database (Denmark)

    Tyrsted, Christoffer; Pauw, Brian; Jensen, Kirsten Marie Ørnsbjerg

    2012-01-01

    Understanding nanoparticle formation reactions requires multitechnique in situ characterisation, since no single characterisation technique provides adequate information. Here, the first combined small-angle X-ray scattering (SAXS)/wide-angle X-ray scattering (WAXS)/total-scattering study of nano...... of nanoparticle formation is presented. We report on the formation and growth of yttria-stabilised zirconia (YSZ) under the extreme conditions of supercritical methanol for particles with Y2O3 equivalent molar fractions of 0, 4, 8, 12 and 25%....

  9. X-ray tube

    International Nuclear Information System (INIS)

    Webley, R.S.

    1975-01-01

    The object of the invention described is to provide an X-ray tube providing a scanned X-ray output which does not require a scanned electron beam. This is obtained by an X-ray tube including an anode which is rotatable about an axis, and a source of a beam of energy, for example an electron beam, arranged to impinge on a surface of the anode to generate X-radiation substantially at the region of incidence on the anode surface. The anode is rotatable about the axis to move the region of incidence over the surface. The anode is so shaped that the rotation causes the region of incidence to move in a predetermined manner relative to fixed parts of the tube so that the generated X-radiation is scanned in a predetermined manner relative to the tube. (UK)

  10. X-ray astronomy

    International Nuclear Information System (INIS)

    Giacconi, R.; Setti, G.

    1980-01-01

    This book contains the lectures, and the most important seminars held at the NATO meeting on X-Ray astronomy in Erice, July 1979. The meeting was an opportune forum to discuss the results of the first 8-months of operation of the X-ray satellite, HEAO-2 (Einstein Observatory) which was launched at the end of 1978. Besides surveying these results, the meeting covered extragalactic astronomy, including the relevant observations obtained in other portions of the electromagnetic spectrum (ultra-violet, optical, infrared and radio). The discussion on galactic X-ray sources essentially covered classical binaries, globular clusters and bursters and its significance to extragalactic sources and to high energy astrophysics was borne in mind. (orig.)

  11. Induction of myeloid leukaemia by whole-body single exposure of CBA male mice to X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Major, I R [Medical Research Council, Harwell (UK). Radiobiological Research Unit

    1979-12-01

    A curvilinear dose response of myeloid leukaemia induction in CBA male mouse was obtained after single whole-body X-irradiation at about 3 months of age. This strain has a very low spontaneous incidence of the disease and no cases were found in the unirradiated controls. The incidence was independent of dose rate over the range used (4.2-552 rad/min). Diagnosis required histopathological examination of various body tissues, the gross anatomical changes being easily confused with other haemopoietic disorders, but a few cases were recognized in life from blood samples. Curve-fitting to various models based on theories of radiocarcinogenic mechanism is described.

  12. Flash x-ray

    International Nuclear Information System (INIS)

    Johnson, Q.; Pellinen, D.

    1976-01-01

    The complementary techniques of flash x-ray radiography (FXR) and flash x-ray diffraction (FXD) provide access to a unique domain in nondestructive materials testing. FXR is useful in studies of macroscopic properties during extremely short time intervals, and FXD, the newer technique, is used in studies of microscopic properties. Although these techniques are similar in many respects, there are some substantial differences. FXD generally requires low-voltage, line-radiation sources and extremely accurate timing; FXR is usually less demanding. Phenomena which can be profitably studied by FXR often can also be studied by FXD to permit a complete materials characterization

  13. X-ray astronomy

    International Nuclear Information System (INIS)

    Narayanan, M.S.

    1976-01-01

    The deployment of detectors outside the deleterious effects of the atmosphere by sending them in space vehicles, has been explained. This has thrown open the entire spectrum of the electromagnetic and particle radiation to direct observations, thus enlarging the vistas of the field of astronomy and astrophysics. The discovery of strong emitters of X-rays such as SCO X-1, NorX-2, transient sources such as Cen X-2, Cen X-4, Cen X-1, Supernova remnants Tan X-1, etc., are reported. The background of the X-ray spectrum as measured during two rocket flights over Thumba, India is presented. (K.B.)

  14. X-ray masks

    International Nuclear Information System (INIS)

    Greenwood, J.C.; Satchell, D.W.

    1984-01-01

    In semiconductor manufacture, where X-ray irradiation is used, a thin silicon membrane can be used as an X-ray mask. This membrane has areas on which are patterns to define the regions to be irradiated. These regions are of antireflection material. With the thin, in the order of 3 microns, membranes used, fragility is a problem. Hence a number of ribs of silicon are formed integral with the membrane, and which are relatively thick, 5 to 10 microns. The ribs may be formed by localised deeper boron deposition followed by a selective etch. (author)

  15. X-ray detector

    International Nuclear Information System (INIS)

    Houston, J.M.; Whetten, N.R.

    1981-01-01

    An ionization chamber for use in determining the spatial distribution of x-ray photons in tomography systems comprises a plurality of substantially parallel, planar anodes separated by parallel, planar cathodes and enclosed in a gas of high atomic weight at a pressure from approximately 10 atmospheres to approximately 50 atmospheres. The cathode and anode structures comprise metals which are substantially opaque to x-ray radiation and thereby tend to reduce the resolution limiting effects of xray fluoresence in the gas. In another embodiment of the invention the anodes comprise parallel conductive bars disposed between two planar cathodes. Guard rings eliminate surface leakage currents between adjacent electrodes

  16. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  17. Subluminous X-ray binaries

    NARCIS (Netherlands)

    Armas Padilla, M.

    2013-01-01

    The discovery of the first X-ray binary, Scorpius X-1, by Giacconi et al. (1962), marked the birth of X-ray astronomy. Following that discovery, many additional X-ray sources where found with the first generation of X-ray rockets and observatories (e.g., UHURU and Einstein). The short-timescale

  18. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: ... Ray Exam: Hip Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  19. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  20. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  1. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  2. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  3. X-Ray Exam: Finger

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  4. Evidence for three types of x-ray damage repair in yeast and sensitivity of totally repair deficient strains to sunlight

    International Nuclear Information System (INIS)

    Game, J.C.; Schild, D.; Mortimer, R.K.

    1987-01-01

    Mutants of yeast that confer sensitivity to x-rays are known to fall into two epistasis groups, called here the RAD51 and RAD18 groups, which are each thought to control a different type of x-ray repair. They examine here the role of genes in a third repair pathways in x-ray repair. RAD1 and RAD3 are known to be important in the repair of pyrimidine dimers after uv-irradiation. They find that these genes can also play an important role in x-ray repair, but that this role is only exposed when both the other pathways of x-ray repair are blocked. Double mutants blocked in the RAD51 and RAD18 pathways are significantly less x-ray sensitive than triple mutants blocked in these pathways but also mutant in either the RAD1 or RAD3 genes. In a related experiment, they tested the importance of DNA repair in nature by determining the sensitivity to natural unfiltered sunlight of a strain lacking all known DNA repair pathways. They constructed a quadruple mutant strain containing RAD1-1, RAD18-2, RAD51-1 and PHR1-1. The latter mutation blocks the cell's ability to photoreactivate uv damage. They found that this strain was so sensitive to sunlight that less than three seconds' exposure would cause an average of one lethal hit per cell, and survival was less than 2% after ten seconds' exposure. Wild type yeast at sea level showed no killing after thirty minutes. the quadruple mutant is approximately one thousand times more sensitive to sunlight than the related wild type

  5. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  6. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  7. Single- and multi-frequency bioelectrical impedance analyses to analyse body composition in maintenance haemodialysis patients: comparison with dual-energy x-ray absorptiometry

    International Nuclear Information System (INIS)

    Donadio, C; Halim, A Ben; Caprio, F; Grassi, G; Khedr, B; Mazzantini, M

    2008-01-01

    The aim of this study was to evaluate the adequacy of single-frequency (sf-BIA) and multi-frequency bioelectrical impedance analyses (mf-BIA), in comparison with dual-energy x-ray absorptiometry (DXA), to evaluate body composition in maintenance haemodialysis (MHD) patients. Body composition of 27 adult MHD patients (9 f, 18 m), BMI 17.5–34.4 kg m −2 , was examined with DXA and BIA, with two different sf-BIA and 1 mf-BIA analysers. Biochemical markers of nutritional status and adequacy of dialytic treatment were also determined. Fat mass (FM) estimated by the different BIA analysers was found to be slightly but significantly higher than FM measured by DXA. In contrast, fat-free mass (FFM) obtained with BIA was found to be slightly but significantly lower than FFM DXA. No significant differences were found between LBM-DXA (that is FFM-DXA minus bone mass) and the different FFM BIA. The lowest mean prediction error versus DXA values was found with sf1BIA. In any case, a close correlation was found between all BIA values and DXA values, particularly for FFM. Furthermore, FFM and LBM results were significantly correlated with serum creatinine, which in MHD patients is an indicator of muscle mass. These results indicate that BIA can be used to evaluate body composition in MHD patients

  8. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  9. Enamel Mineral Content Changes After Bleaching With High and Low Hydrogen Peroxide Concentrations: Colorimetric Spectrophotometry and Total Reflection X-ray Fluorescence Analyses.

    Science.gov (United States)

    Pinto, Avd; Bridi, E C; Amaral, Flb; França, Fmg; Turssi, C P; Pérez, C A; Martinez, E F; Flório, F M; Basting, R T

    The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r 2 =-0.020) and P (p=0.728, r 2 =0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.

  10. ADRB2 gene variants, dual-energy x-ray absorptiometry body composition, and hypertension in Tobago men of African descent.

    Science.gov (United States)

    Beason, Tracey Samantha; Bunker, Clareann H; Zmuda, Joseph M; Wilson, John W; Patrick, Alan L; Wheeler, Victor W; Weissfeld, Joel L

    2011-05-01

    Classic tissue effects of β(2)-adrenergic receptor activation include skeletal muscle glycogenolysis and vascular smooth muscle relaxation, factors relevant to obesity and hypertension, respectively. In a population-based study, we examined 2 common amino acid substitutions in the β(2)-adrenergic receptor gene (ADRB2) in relation to body composition and blood pressure. A cross-sectional analysis of 1893 African-descent men living in Tobago and participating in a prostate cancer screening study was performed. Body mass index, waist circumference, blood pressure, dual-energy x-ray absorptiometry body composition, and ADRB2 (Arg16Gly; Gln27Glu) genotype were determined. Twenty-six percent were obese (body mass index ≥30 kg/m(2)), and 50% were hypertensive. ADRB2 Arg16Gly and Gln27Glu alleles were in linkage disequilibrium (D' = 0.96, r(2) = 0.15). ADRB2 16Gly-containing and 27Glu-containing genotypes were equally frequent in low, medium, and high tertiles of percentage of body fat mass (16Gly-containing genotypes: 73.4%, 74.4%, and 74.5%, P(trend) = .66; 27Glu-containing genotypes: 27.6%, 23.8%, and 25.4%, P(trend) = .39) and in normal blood pressure, prehypertensive, and hypertensive men (16Gly-containing genotypes: 73.4%, 72.8%, and 74.4%, P(trend) = .61; 27Glu-containing genotypes: 25.6%, 24.1%, and 26.7%, P(trend) = .50). In a high-obesity and high-hypertension risk population with ancestry in common with African Americans, genetic variation defined by 2 common ADRB2 amino acid substitutions was not associated with body composition or hypertension. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Chest X-Ray

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  12. X-ray sources

    International Nuclear Information System (INIS)

    Bonse, U.

    1979-11-01

    The author describes several possibilities for the production of X-radiation. Especially he discusses the use of bremsstrahlung at electron impact on solid targets and the synchrotron radiation. He presents some equations for the calculation of X-ray intensities. Especially the X-radiation from the DORIS storage ring is discussed. (HSI)

  13. Medical x-ray

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Gui Ah Auu; Husaini Salleh; Idris Besar; Mohd Ashhar Khalid; Muhammad Jamal Md Isa; Shaharuddin Mohd; Siti Najila Mohd Janib; Mohamed Ali Abdul Khader; Mahalatchimi Dave; Mohd Fazly Abdul Rahim; Ng Chee Moon; Ram Piari; Teoh Hoon Heng; Lee Peter

    2004-01-01

    This book describes the fundamental subject about medical radiography. It is a multidisciplinary field that requires cross professional input from scientists, engineers and medical doctors. However, it is presented in simple language to suit different levels of readers from x-ray operators and radiographers to physists, general practitioners and radiology specialists.The book is written in accordance to the requirements of the standard syllabus approved by the Ministry of Health Malaysia for the training of medical x-ray operator and general practitioners. In general, the content is not only designed to provide relevant and essential subject for related professionals in medical radiological services such as x-ray operator, radiographer and radiologists, but also to address those in associated radiological services including nurses, medical technologists and physicists.The book is organized and arranged sequentially into 3 parts for easy reference: Radiation safety; X-ray equipment and associated facilities; Radiography practices. With proper grasping of all these parts, the radiological services could be provided with confident and the highest professional standard. Thus, medical imaging with highest quality that can provide useful diagnostic information at minimum doses and at cost effective could be assured

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... change into a gown. You may have some concerns about chest x-rays. However, it’s important to ... You Sponsored by About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  15. Sequential hemi-body radiotherapy in advanced multiple myeloma. [Side effects of indicated x-ray therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, J.P.; Bosch, A.; Raich, P.C.

    1979-01-01

    Eleven patients with advanced multiple myeloma refractory to standard chemotherapy were treated with a regimen of sequential hemi-body radiotherapy consisting of 800 rad midplane in a single dose to each half. 9/10 patients experienced significant relief of skeletal pain and there were 5/11 objective tumor responses with one complete remission. Treatment-related morbidity was significant and consisted primarily of nausea and emesis, bone marrow suppression, and pneumonitis. This therapy is helpful in the management of advanced myeloma, and should be studied earlier in the course of the disease.

  16. X-ray Outburst in Mira A

    OpenAIRE

    Karovska, M.; Schlegel, E.; Hack, W.; Wood, B.

    2005-01-01

    We report here the Chandra ACIS-S detection of a bright soft X-ray transient in the Mira AB interacting symbiotic-like binary. We resolved the system for the first time in the X-rays. Using Chandra and HST images we determined that the unprecedented outburst is likely associated with the cool AGB star (Mira A), the prototype of Mira-type variables. X-rays have never before been detected from an AGB star, and the recent activity signals that the system is undergoing dramatic changes. The total...

  17. X-ray area monitor

    International Nuclear Information System (INIS)

    Nintrakit, N.

    1983-01-01

    The X-ray area monitor is a nuclear electronic device that is essential in radiation protection in high radiation laboratories, e.g. in medical diagnosis using X-rays and in industrial X-radiography. Accidentally the level of X-radiator may arise above the safe permissible level and in such a case the alarm system of the area monitor will work and disconnect the ac power supply form the X-ray unit. Principally the device is a radiation counter using G.M.tube as radiation detector with high voltage supply variable form 200 to 2,000 volts. The maximum count rate of the scaler is 1.5 MHz and the total count is displayed on 4 digit LED's. A time base is used to control the counting time, the frequency multiplier, radiation safety limit, comparator and the radiation hazard warning signal. The reliability of the instrument is further enhanced through the addition of the random correction circuit, and it is applicable both in X- and γ -radiation

  18. Study of air pollution in terms of heavy metals and particulate matter at Ambodin'isotry using the technique of total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    AHMED, H.

    2011-01-01

    The present work is devoted to study the air pollution in terms of particulate matters and heavy metals in Ambodin'isotry in Antananarivo city by the method of total reflection X-ray fluorescence. This work has been done within the Institut National des Sciences et Techniques Nucleaires (Madagascar-INSTN). GENT air sampler has been used for the collections of the aerosol samples. This air sampler is placed at about 7 meters above the ground in order to avoid the contaminations. The samplings were carried out from 14 April to 29 August 2008. The duration of sampling is 24 hours. The results show that the analyzed aerosol samples contain the elements like the titanium , the chromium, the manganese, the iron, the nickel, the copper, the zinc, the bromine, the strontium and the lead. The average concentrations in element lead are lower than the standards ones adopted by the World Health Organization (WHO) (500 ng.m -3 ) and the United States Environmental Protection Agency (US EPA) (1500 ng.m -3 ). The total average concentrations in element lead are lower than the standards ones adopted by the World Health Organization (WHO) (500 ng.m -3 ). The total of average concentrations in lead doesn't present a danger for the population of Ambodin'isotry. The average concentrations of PM10 in the aerosols do not respect the guideline values of 50μg.m -3 adopted by the WHO and the European Union according to the directive 2005 and those of PM 2.5 exceed extensively the guideline values of the WHO (25μg.m -3 ) and of the US EPA (35μg.m -3 ). Consequently, the site of Ambodin'Isotry is polluted in term of airborne particulate matters. The calculation of enrichment factors by Mason's model shows the titanium, the iron, the nickel and the strontium are natural origin while the chromium, the nickel, the copper, the zinc, the bromine and the lead are from anthropogenic sources. [fr

  19. Studies on the Chromatin Isolated from the Organs of Animals Received Whole-body X-ray Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Nam [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1967-09-15

    Within experimental chromatin, the total protein: DNA ratio did not vary in the same organs of control and irradiated rats. However, the amount of RNA and total protein associated with the DNA varied considerably among the different types of chromatin. In particular, the content of chromatin was the highest in the irradiated tissue, and the lowest in the chromatin control tissue. RNA and total protein ratio of chromatins from brain, liver, testis and spleen declined with experimental organs. 2) There was the same quantitative relationship between the amount of RNA and the amount histone-protein associated with DNA in each chromatin. 3) RNA:DNA ratio of chromatin showed a 1.5-2 times increase in the irradiated organs except brain. However, RNA:DNA ratio was decreased in chromatin by irradiation. 4) Histone-protein: Residual protein ratio was greatly varied among the organs. However, the effect was not found by irradiation. 5) Priming activity of chromatins showed a higher value in testis and the activity was greater in organs with higher metabolic activity. 6) Inhibition of Actinomycin D observable in chromatin for testis, liver, spleen and brain declined without relationship between irradiated and non-irradiated conditions. Ammonium sulfate in DNA of chromatin from histone showed increased priming activity with dissociation by Electrostatics. It may give different effect of ammonium sulfate on stimulation by property of chromatins. 7) It is suggested that the results support a proposal that the higher sensitivity of radioactive in testis, spleen by irradiated showed a increase and decrease lower-sensitivity of radioactive from brain, liver than did priming activity under the radioactive conditions.

  20. Studies on the Chromatin Isolated from the Organs of Animals Received Whole-body X-ray Irradiation

    International Nuclear Information System (INIS)

    Han, Su Nam

    1967-01-01

    Within experimental chromatin, the total protein: DNA ratio did not vary in the same organs of control and irradiated rats. However, the amount of RNA and total protein associated with the DNA varied considerably among the different types of chromatin. In particular, the content of chromatin was the highest in the irradiated tissue, and the lowest in the chromatin control tissue. RNA and total protein ratio of chromatins from brain, liver, testis and spleen declined with experimental organs. 2) There was the same quantitative relationship between the amount of RNA and the amount histone-protein associated with DNA in each chromatin. 3) RNA:DNA ratio of chromatin showed a 1.5-2 times increase in the irradiated organs except brain. However, RNA:DNA ratio was decreased in chromatin by irradiation. 4) Histone-protein: Residual protein ratio was greatly varied among the organs. However, the effect was not found by irradiation. 5) Priming activity of chromatins showed a higher value in testis and the activity was greater in organs with higher metabolic activity. 6) Inhibition of Actinomycin D observable in chromatin for testis, liver, spleen and brain declined without relationship between irradiated and non-irradiated conditions. Ammonium sulfate in DNA of chromatin from histone showed increased priming activity with dissociation by Electrostatics. It may give different effect of ammonium sulfate on stimulation by property of chromatins. 7) It is suggested that the results support a proposal that the higher sensitivity of radioactive in testis, spleen by irradiated showed a increase and decrease lower-sensitivity of radioactive from brain, liver than did priming activity under the radioactive conditions.

  1. Assessment of PCXMC for patients with different body size in chest and abdominal x ray examinations: a Monte Carlo simulation study

    Science.gov (United States)

    Borrego, David; Lowe, Erin M.; Kitahara, Cari M.; Lee, Choonsik

    2018-03-01

    A PC Program for x ray Monte Carlo (PCXMC) has been used to calculate organ doses in patient dosimetry and for the exposure assessment in epidemiological studies of radiogenic health related risks. This study compared the dosimetry from using the built-in stylized phantoms in the PCXMC to that of a newer hybrid phantom library with improved anatomical realism. We simulated chest and abdominal x ray projections for 146 unique body size computational phantoms, 77 males and 69 females, with different combinations of height (125–180 cm) and weight (20–140 kg) using the built-in stylized phantoms in the PCXMC version 2.0.1.4 and the hybrid phantom library using the Monte Carlo N-particle eXtended transport code 2.7 (MCNPX). Unfortunately, it was not possible to incorporate the hybrid phantom library into the PCXMC. We compared 14 organ doses, including dose to the active bone marrow, to evaluate differences between the built-in stylized phantoms in the PCXMC and the hybrid phantoms (Cristy and Eckerman 1987 Technical Report ORNL/TM-8381/V1, Oak Ridge National Laboratory, Eckerman and Ryman 1993 Technical Report 12 Oak Ridge, TN, Geyer et al 2014 Phys. Med. Biol. 59 5225–42). On average, organ doses calculated using the built-in stylized phantoms in the PCXMC were greater when compared to the hybrid phantoms. This is most prominent in AP abdominal exams by an average factor of 2.4-, 2.8-, and 2.8-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. For chest exams, organ doses are greater by an average factor of 1.1-, 1.4-, and 1.2-fold for the 10-year-old, 15-year-old, and adult phantoms, respectively. The PCXMX, due to its ease of use, is often selected to support dosimetry in epidemiological studies; however, it uses simplified models of the human anatomy that fail to account for variations in body morphometry for increasing weight. For epidemiological studies that use PCXMC dosimetry, associations between radiation-related disease risks

  2. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  3. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  4. X-ray refractometer

    International Nuclear Information System (INIS)

    Tur'yanskij, A.G.; Pirshin, I.V.

    2001-01-01

    Paper introduces a new circuit of X-ray refractometer to study angular and spectral features of refracted radiation within hard X-ray range. Refractometer incorporates two goniometers, two crystal-analyzers and three radiation detectors. The maximum distance between radiation source focal point and a receiving slit of the second goniometer is equal to 1.4 m. For the first time one obtained refraction patterns of fine-film specimens including C/Si stressed structure. Paper describes a new technique of refractometry via specimen oscillation at fixed position of a detecting device. Paper presents the measurement results of oscillation refraction patterns for specimens of melted quartz and ZnSe single crystal [ru

  5. X-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Zucarias, A; Shepherd, J W

    1982-09-08

    An X-ray tube has a tubular envelope with a cathode for directing an electron beam onto a focal spot area of a spaced anode target to generate X-rays. The target is mounted for axial rotation on one end of a rotor disposed in an end portion of the envelope and encircled by a stator of an alternating current induction motor. An annular shield of high permeability magnetic material extends transversely between the electron beam and the stator of the induction motor for shunting stray or fringe electromagnetic fields established by the stator away from the electron beam to avoid consequent lateral deflections of the electron and corresponding lateral movements of the focal spot area.

  6. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  7. X-ray apparatus

    International Nuclear Information System (INIS)

    Tomita, Chuji.

    1980-01-01

    A principal object of the present invention is to provide an X-ray apparatus which is such that the distance between the surface of the patient's table and the floor on which the apparatus is installed is sufficiently small in the horizontal position of the patient's table of the roentgenographical pedestal and that the rotation of the pedestal from the horizontal position to a tilted position and further to the vertical position of the table can be carried out smoothly. (auth)

  8. Hygrothermal degradation of (3-glycidoxypropyl)trimethoxysilane films studied by neutron and X-ray reflectivity and attenuated total reflection infrared spectroscopy

    International Nuclear Information System (INIS)

    Tallant, David Robert; Garcia, Manuel Joseph; Majewski, Jaroslaw; Kent, Michael Stuart; Yim, Hyun

    2005-01-01

    Thin films of organosilanes have great technological importance in the areas of adhesion promotion, durability, and corrosion resistance. However, it is well-known that water can degrade organosilane films, particularly at elevated temperatures. In this work, X-ray and neutron reflectivity (XR and NR) were combined with attenuated total reflection infrared (ATR-IR) spectroscopy to study the chemical and structural changes within thin films of (3-glycidoxypropyl)trimethoxysilane (GPS) after exposure for various periods of time to air saturated with either D 2 O or H 2 O at 80 C. For NR and XR, ultrathin (∼100 (angstrom)) films were prepared by spin-coating. Both D 2 O and H 2 O provide neutron scattering contrast with GPS. Variations in the neutron scattering length density (SLD) profiles (a function of mass density and atomic composition) with conditioning time were measured after drying the samples out and also swelled with H 2 O or D 2 O vapor at room temperature. For samples that were dried out prior to measurement, little or no change was observed for H 2 O conditioning up to 3.5 days, but large changes were observed after 30 days of conditioning. The range of conditioning time for this structural change was narrowed to between 4 and 10 days with XR. The SLD profiles indicated that the top portion of the GPS film was transformed into a thick low-density layer after conditioning, but the bottom portion showed little structural change. A previous NR study of as-prepared GPS films involving swelling with deuterated nitrobenzene showed that the central portion of the film has much lower cross-link density than the region nearest the substrate. The present data show that the central portion also swells to a much greater extent with water and hydrolyzes more rapidly. The chemical degradation mechanism was identified by IR as hydrolysis of siloxane bonds. For ATR-IR, GPS films were prepared by dip-coating, which resulted in a greater and more variable thickness than

  9. Energy-dispersive x-Ray Analysis of Phosphorus, Potassium, Magnesium, and Calcium in Globoid Crystals in Protein Bodies from Different Regions of Cucurbita maxima Embryos 1

    Science.gov (United States)

    Lott, John N. A.; Greenwood, John S.; Vollmer, Catherine M.; Buttrose, Mark S.

    1978-01-01

    The seeds of Cucurbita maxima contain protein bodies with electrondense globoid crystals. Because of their density globoid crystals are ideal material for energy-dispersive x-ray (EDX) analysis studies of elemental composition. Fixation trials were carried out to test globoid crystal extraction during glutaraldehyde fixation, water washing, and ethanol dehydration. Glutaraldehyde fixation without subsequent washing or dehydration alone produced no significant changes in elemental composition of cotyledon globoid crystals. If glutaraldehyde fixation was followed by water washes or ethanol dehydration there was some loss of the major globoid crystal elements but the relative percentages of the elements P, K, Ca, and Mg remained relatively unchanged. In this paper results of a study of the P, K, Mg, and Ca content of globoid crystals in different tissues of squash embryos are presented. The globoid crystals in the radicle were found to be the least dense in the embryo. Globoid crystals from all embryo regions contained P, K, and Mg. In the various embryo regions P and Mg maintained relatively constant proportions of the globoid crystal composition while K and Ca varied. Of particular significance is the distribution of Ca which is generally an immobile element. Calcium was found in highest amounts in the globoid crystals of the radicle and stem regions while globoid crystals in much of the cotyledon contained little, if any, Ca. The Ca storage thus seems to be spatially arranged in a manner that would aid early growth of the root-shoot axis. PMID:16660439

  10. Precision of high-resolution dual energy x-ray absorptiometry of bone mineral status and body composition in small animal models

    Directory of Open Access Journals (Sweden)

    Lochmüller E. M.

    2001-01-01

    Full Text Available The purpose of this study was to analyze the in situ precision (reproducibility of bone mineral and body composition measurements in mice of different body weights and rats, using a high-resolution DXA (dual energy X-ray absorptiometry scanner. We examined 48 NMRI mice weighing approximately 10 to 60 g, and 10 rats weighing approximately 140 g. Four repeated measurements were obtained on different days. In mice, the standard deviations of repeated measurements ranged from 2.5 to 242 mg for bone mineral content (BMC, from 0.16 to 3.74 g for fat, and from 0.40 to 4.21 g for lean mass. The coefficient of variation in percent (CV% for BMC/BMD (bone mineral density was highest in the 10 g mice (12.8% / 4.9% and lowest in the 40 g mice (3.5% /1.7%. In rats, it was 2.5 /1.2% in the lower extremity, 7.1/3.0 % in the spine, 5.7/2.0 % in the femur, and 3.6%/2.1% in the tibia. The CV% for fat and lean mass in mice was higher than for BMC. The study demonstrates good precision of bone mineral and moderate precision of body composition measure-ments in small animals, using a high-resolution DXA system. The technique can be used for testing the efficacy of drugs in small animal models, for muta-genesis screens, and for the phenotypic characterization of transgenic mice.

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... can be taken to the patient in a hospital bed or the emergency room. The x-ray ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  14. X-ray detector array

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    The object of the invention (an ionization chamber X-ray detector array for use with high speed computerised tomographic imaging apparatus) is to reduce the time required to produce a tomographic image. The detector array described determines the distribution of X-ray intensities in one or more flat, coplanar X-ray beams. It comprises three flat anode sheets parallel to the X-ray beam, a plurality of rod-like cathodes between the anodes, a detector gas between the electrodes and a means for applying a potential between the electrodes. Each of the X-ray sources is collimated to give a narrow, planar section of X-ray photons. Sets of X-ray sources in the array are pulsed simultaneously to obtain X-ray transmission data for tomographic image reconstruction. (U.K.)

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... changes seen in metabolic conditions. assist in the detection and diagnosis of bone cancer . locate foreign objects ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... up in shades of gray and air appears black. Until recently, x-ray images were maintained on ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... wrist, arm, elbow, shoulder, spine, pelvis, hip, thigh, knee, leg (shin), ankle or foot. top of page ... the patient standing upright, as in cases of knee x-rays. A portable x-ray machine is ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...